GUDEADS-EPC1121-MIB
Gude Analog- und Digitalsysteme GmbHExpert Power Control 1121 MIB
snmptranslate -m GUDEADS-EPC1121-MIB -Tpsnmpwalk -v2c -c <community> -m GUDEADS-EPC1121-MIB <host> 1.3.6.1.4.1.28507Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Igudeads | 1.3.6.1.4.1.28507 | |||
identity Expert Power Control 1121 MIB | ||||
| NgadsEPC1121 | 1.3.6.1.4.1.28507.107 | |||
| Nepc1121Objects | 1.3.6.1.4.1.28507.107.1 | |||
| Nepc1121CommonConfig | 1.3.6.1.4.1.28507.107.1.1 | |||
| Nepc1121SNMPaccess | 1.3.6.1.4.1.28507.107.1.1.1 | |||
| Sepc1121TrapCtrl | 1.3.6.1.4.1.28507.107.1.1.1.1 | Integer32 (0..3) | RW | |
scalar · Integer32 (0..3) · read-write · current 0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3 | ||||
| Tepc1121TrapIPTable | 1.3.6.1.4.1.28507.107.1.1.1.2 | NA | ||
table · not-accessible · current list of all Trap receiver | ||||
| Repc1121TrapIPEntry | 1.3.6.1.4.1.28507.107.1.1.1.2.1 | NA | ||
row · not-accessible · current an entry containing management informations regarding the list of trap receivers
| ||||
| Cepc1121TrapIPIndex | 1.3.6.1.4.1.28507.107.1.1.1.2.1.1 | Integer32 (1..8) | RO | |
column · Integer32 (1..8) · read-only · current A unique value, greater than zero, for each receiver slot. | ||||
| Cepc1121TrapAddr | 1.3.6.1.4.1.28507.107.1.1.1.2.1.2 | OCTET STRING (SIZE (0..99)) | RW | |
column · OCTET STRING (SIZE (0..99)) · read-write · current DNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot. | ||||
| Nepc1121DeviceInfo | 1.3.6.1.4.1.28507.107.1.1.2 | |||
| Sepc1121ProdName | 1.3.6.1.4.1.28507.107.1.1.2.1 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current The Product Name of the device. | ||||
| Sepc1121FWVersion | 1.3.6.1.4.1.28507.107.1.1.2.2 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current Firmware Version of the device. | ||||
| Sepc1121HostName | 1.3.6.1.4.1.28507.107.1.1.2.3 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current The configured Host Name. | ||||
| Sepc1121PhysAddress | 1.3.6.1.4.1.28507.107.1.1.2.4 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current The MAC address of the device. | ||||
| Sepc1121SerialNumber | 1.3.6.1.4.1.28507.107.1.1.2.5 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current The Serial Number of the device. Not available for all devices. Production start 2026. | ||||
| Nepc1121DeviceConfig | 1.3.6.1.4.1.28507.107.1.2 | |||
| Nepc1121IntActors | 1.3.6.1.4.1.28507.107.1.3 | |||
| Nepc1121relayports | 1.3.6.1.4.1.28507.107.1.3.1 | |||
| Sepc1121portNumber | 1.3.6.1.4.1.28507.107.1.3.1.1 | Integer32 (1..2) | RO | |
scalar · Integer32 (1..2) · read-only · current The number of Relay Ports | ||||
| Tepc1121portTable | 1.3.6.1.4.1.28507.107.1.3.1.2 | NA | ||
table · not-accessible · current list of all EPC Relay Ports | ||||
| Repc1121portEntry | 1.3.6.1.4.1.28507.107.1.3.1.2.1 | NA | ||
row · not-accessible · current An entry containing management information applicable to a particular relay port.
| ||||
| Cepc1121PortIndex | 1.3.6.1.4.1.28507.107.1.3.1.2.1.1 | Integer32 (1..2) | RO | |
column · Integer32 (1..2) · read-only · current A unique value, greater than zero, for each Relay Port. | ||||
| Cepc1121PortName | 1.3.6.1.4.1.28507.107.1.3.1.2.1.2 | OCTET STRING (SIZE (0..15)) | RW | |
column · OCTET STRING (SIZE (0..15)) · read-write · current A textual string containing name of a Relay Port. | ||||
| Cepc1121PortState | 1.3.6.1.4.1.28507.107.1.3.1.2.1.3 | INTEGER | RW | |
column · INTEGER · read-write · current current state a Relay Port
| ||||
| Cepc1121PortSwitchCount | 1.3.6.1.4.1.28507.107.1.3.1.2.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current The total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here. | ||||
| Cepc1121PortStartupMode | 1.3.6.1.4.1.28507.107.1.3.1.2.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current set Mode of startup sequence (off, on , remember last state)
| ||||
| Cepc1121PortStartupDelay | 1.3.6.1.4.1.28507.107.1.3.1.2.1.6 | Integer32 | RW | |
column · Integer32 · read-write · current Delay in sec for startup action
| ||||
| Cepc1121PortRepowerTime | 1.3.6.1.4.1.28507.107.1.3.1.2.1.7 | Integer32 (0..65535) | RW | |
column · Integer32 (0..65535) · read-write · current Delay in sec for repower port after switching off
| ||||
| Cepc1121PortResetDuration | 1.3.6.1.4.1.28507.107.1.3.1.2.1.8 | Integer32 (0..65535) | RW | |
column · Integer32 (0..65535) · read-write · current Delay in sec for turning Port on again after Reset action
| ||||
| Nepc1121ExtActors | 1.3.6.1.4.1.28507.107.1.4 | |||
| Nepc1121IntSensors | 1.3.6.1.4.1.28507.107.1.5 | |||
| Nepc1121PowerChan | 1.3.6.1.4.1.28507.107.1.5.1 | |||
| Sepc1121ActivePowerChan | 1.3.6.1.4.1.28507.107.1.5.1.1 | Unsigned32 (1) | RO | |
scalar · Unsigned32 (1) · read-only · current Number of suppported Power Channels. | ||||
| Tepc1121PowerTable | 1.3.6.1.4.1.28507.107.1.5.1.2 | NA | ||
table · not-accessible · current All available Channel Interfaces. | ||||
| Repc1121PowerEntry | 1.3.6.1.4.1.28507.107.1.5.1.2.1 | NA | ||
row · not-accessible · current An entry containing management information applicable to a particular Power Channel.
| ||||
| Cepc1121PowerIndex | 1.3.6.1.4.1.28507.107.1.5.1.2.1.1 | Integer32 (1) | RO | |
column · Integer32 (1) · read-only · current Index of Power Channel entries | ||||
| Cepc1121ChanStatus | 1.3.6.1.4.1.28507.107.1.5.1.2.1.2 | Integer32 (0..1) | RO | |
column · Integer32 (0..1) · read-only · current 0 = data not active, 1 = data valid | ||||
| Cepc1121AbsEnergyActive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.3 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Absolute Active Energy counter.
| ||||
| Cepc1121PowerActive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current Active Power
| ||||
| Cepc1121Current | 1.3.6.1.4.1.28507.107.1.5.1.2.1.5 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Curent on Power Channel.
| ||||
| Cepc1121Voltage | 1.3.6.1.4.1.28507.107.1.5.1.2.1.6 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Actual Voltage on Power Channel
| ||||
| Cepc1121Frequency | 1.3.6.1.4.1.28507.107.1.5.1.2.1.7 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Frequency of Power Channel
| ||||
| Cepc1121PowerFactor | 1.3.6.1.4.1.28507.107.1.5.1.2.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current Power Factor of Channel between -1.0 and 1.00
| ||||
| Cepc1121Pangle | 1.3.6.1.4.1.28507.107.1.5.1.2.1.9 | Integer32 | RO | |
column · Integer32 · read-only · current Phase Angle between Voltage and L Line Current between -180.0 and 180.0
| ||||
| Cepc1121PowerApparent | 1.3.6.1.4.1.28507.107.1.5.1.2.1.10 | Integer32 | RO | |
column · Integer32 · read-only · current L Line Mean Apparent Power
| ||||
| Cepc1121PowerReactive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.11 | Integer32 | RO | |
column · Integer32 · read-only · current L Line Mean Reactive Power
| ||||
| Cepc1121AbsEnergyReactive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.12 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Absolute Reactive Energy counter.
| ||||
| Cepc1121AbsEnergyActiveResettable | 1.3.6.1.4.1.28507.107.1.5.1.2.1.13 | Unsigned32 | RW | |
column · Unsigned32 · read-write · current Resettable Absolute Active Energy counter. Writing '0' resets all resettable counter.
| ||||
| Cepc1121AbsEnergyReactiveResettable | 1.3.6.1.4.1.28507.107.1.5.1.2.1.14 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Resettable Absolute Reactive Energy counter.
| ||||
| Cepc1121ResetTime | 1.3.6.1.4.1.28507.107.1.5.1.2.1.15 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Time in seconds since last Energy Counter reset.
| ||||
| Cepc1121ForwEnergyActive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.16 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Forward Active Energy counter.
| ||||
| Cepc1121ForwEnergyReactive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.17 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Forward Reactive Energy counter.
| ||||
| Cepc1121ForwEnergyActiveResettable | 1.3.6.1.4.1.28507.107.1.5.1.2.1.18 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Resettable Forward Active Energy counter.
| ||||
| Cepc1121ForwEnergyReactiveResettable | 1.3.6.1.4.1.28507.107.1.5.1.2.1.19 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Resettable Forward Reactive Energy counter.
| ||||
| Cepc1121RevEnergyActive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.20 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Reverse Active Energy counter.
| ||||
| Cepc1121RevEnergyReactive | 1.3.6.1.4.1.28507.107.1.5.1.2.1.21 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Reverse Reactive Energy counter.
| ||||
| Cepc1121RevEnergyActiveResettable | 1.3.6.1.4.1.28507.107.1.5.1.2.1.22 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Resettable Reverse Active Energy counter.
| ||||
| Cepc1121RevEnergyReactiveResettable | 1.3.6.1.4.1.28507.107.1.5.1.2.1.23 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Resettable Reverse Reactive Energy counter.
| ||||
| Cepc1121LineSensorName | 1.3.6.1.4.1.28507.107.1.5.1.2.1.100 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a Line Sensor | ||||
| Tepc1121OVPTable | 1.3.6.1.4.1.28507.107.1.5.2 | NA | ||
table · not-accessible · current Overvoltage Protection Table This table may not be present on devices without OVP feature | ||||
| Repc1121OVPEntry | 1.3.6.1.4.1.28507.107.1.5.2.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc1121OVPIndex | 1.3.6.1.4.1.28507.107.1.5.2.1.1 | Integer32 (1) | RO | |
| Cepc1121OVPStatus | 1.3.6.1.4.1.28507.107.1.5.2.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current shows the status of the built-in Overvoltage Protection
| ||||
| Nepc1121CPUSensors | 1.3.6.1.4.1.28507.107.1.5.14 | |||
| Sepc1121CPUSensorVsystem | 1.3.6.1.4.1.28507.107.1.5.14.1 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current System Voltage on CPU Board
| ||||
| Sepc1121CPUSensorVaux | 1.3.6.1.4.1.28507.107.1.5.14.2 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Auxiliary Voltage on CPU Board
| ||||
| Sepc1121CPUSensorVmain | 1.3.6.1.4.1.28507.107.1.5.14.3 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Main Voltage on CPU Board
| ||||
| Nepc1121NTPClient | 1.3.6.1.4.1.28507.107.1.5.15 | |||
| Sepc1121NTPTimeValid | 1.3.6.1.4.1.28507.107.1.5.15.1 | INTEGER | RO | |
scalar · INTEGER · read-only · current Show if valid Time is received
| ||||
| Sepc1121NTPUnixTime | 1.3.6.1.4.1.28507.107.1.5.15.2 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current show received NTP time as unixtime (secs since 1 January 1970)
| ||||
| Sepc1121NTPLastValidTimestamp | 1.3.6.1.4.1.28507.107.1.5.15.3 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current show seconds since last valid NTP timestamp received
| ||||
| Nepc1121ExtSensors | 1.3.6.1.4.1.28507.107.1.6 | |||
| Tepc1121SensorTable | 1.3.6.1.4.1.28507.107.1.6.1 | NA | ||
| Repc1121SensorEntry | 1.3.6.1.4.1.28507.107.1.6.1.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc1121SensorIndex | 1.3.6.1.4.1.28507.107.1.6.1.1.1 | Integer32 (1) | RO | |
| Cepc1121TempSensor | 1.3.6.1.4.1.28507.107.1.6.1.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current actual temperature | ||||
| Cepc1121HygroSensor | 1.3.6.1.4.1.28507.107.1.6.1.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current actual humidity
| ||||
| Cepc1121AirPressure | 1.3.6.1.4.1.28507.107.1.6.1.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current actual air pressure | ||||
| Cepc1121DewPoint | 1.3.6.1.4.1.28507.107.1.6.1.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current dew point for actual temperature and humidity | ||||
| Cepc1121DewPointDiff | 1.3.6.1.4.1.28507.107.1.6.1.1.7 | Integer32 | RO | |
column · Integer32 · read-only · current difference between dew point and actual temperature (Temp - DewPoint) | ||||
| Cepc1121ExtSensorName | 1.3.6.1.4.1.28507.107.1.6.1.1.32 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of a external Sensor | ||||
| Nepc1121ExtInputs | 1.3.6.1.4.1.28507.107.1.6.2 | |||
| Sepc1121ExtActiveInputs | 1.3.6.1.4.1.28507.107.1.6.2.1 | Unsigned32 | RO | |
scalar · Unsigned32 · read-only · current Number of suppported Input Channels. | ||||
| Tepc1121ExtInputTable | 1.3.6.1.4.1.28507.107.1.6.2.2 | NA | ||
| Repc1121ExtInputEntry | 1.3.6.1.4.1.28507.107.1.6.2.2.1 | NA | ||
row · not-accessible · current
| ||||
| Cepc1121ExtInputIndex | 1.3.6.1.4.1.28507.107.1.6.2.2.1.1 | Unsigned32 | RO | |
| Cepc1121ExtInput | 1.3.6.1.4.1.28507.107.1.6.2.2.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current Input state of device
| ||||
| Cepc1121ExtInputToggleCount | 1.3.6.1.4.1.28507.107.1.6.2.2.1.3 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Number of times the Input has changed its state. | ||||
| Cepc1121ExtInputName | 1.3.6.1.4.1.28507.107.1.6.2.2.1.32 | OCTET STRING (SIZE (0..32)) | RW | |
column · OCTET STRING (SIZE (0..32)) · read-write · current A textual string containing name of the Input | ||||
| Cepc1121ExtInputPortNum | 1.3.6.1.4.1.28507.107.1.6.2.2.1.33 | Integer32 | RO | |
column · Integer32 · read-only · current Number of external Sensor Port when value greater zero, else device built-in Input. | ||||
| Cepc1121ExtInputBlockIndex | 1.3.6.1.4.1.28507.107.1.6.2.2.1.34 | Integer32 | RO | |
column · Integer32 · read-only · current Either index of device built-in Input, or index of Input in external sensor. | ||||
| Nepc1121Conf | 1.3.6.1.4.1.28507.107.2 | |||
| Nepc1121Groups | 1.3.6.1.4.1.28507.107.2.1 | |||
| Gepc1121BasicGroup | 1.3.6.1.4.1.28507.107.2.1.1 | |||
group · current Basic objects.
| ||||
| Gepc1121NotificationGroup | 1.3.6.1.4.1.28507.107.2.1.2 | |||
| Nepc1121Compls | 1.3.6.1.4.1.28507.107.2.2 | |||
| Nevents | 1.3.6.1.4.1.28507.107.3 | |||
| !epc1121SwitchEvtPort | 1.3.6.1.4.1.28507.107.3.1 | |||
notification · current Event is triggered when a port is switched | ||||
| !epc1121TempEvtSen | 1.3.6.1.4.1.28507.107.3.2 | |||
| !epc1121HygroEvtSen | 1.3.6.1.4.1.28507.107.3.3 | |||
| !epc1121AirPressureEvtSen | 1.3.6.1.4.1.28507.107.3.4 | |||
| !epc1121DewPtDiffEvtSen | 1.3.6.1.4.1.28507.107.3.5 | |||
notification · current Dew Point Difference limits exceeded | ||||
| !epc1121OVPEvt | 1.3.6.1.4.1.28507.107.3.6 | |||
notification · current Event is triggered when the OVP status changes
| ||||
| !epc1121LineAmperageEvt | 1.3.6.1.4.1.28507.107.3.7 | |||
notification · current Event is triggered when a measured current is crossing the entered limits | ||||
| !epc1121ExtInputEvt | 1.3.6.1.4.1.28507.107.3.25 | |||
notification · current Change of external sensor input. | ||||
| !epc1121LineVoltageEvt | 1.3.6.1.4.1.28507.107.3.26 | |||
notification · current Event is triggered when a measured voltage is crossing the entered limits | ||||
| !epc1121LinePowerEvt | 1.3.6.1.4.1.28507.107.3.27 | |||
notification · current Event is triggered when a measured power is crossing the entered limits | ||||
Traps / Notifications
- epc1121AirPressureEvtSen
1.3.6.1.4.1.28507.107.3.4 - epc1121DewPtDiffEvtSen
1.3.6.1.4.1.28507.107.3.5 - epc1121ExtInputEvt
1.3.6.1.4.1.28507.107.3.25 - epc1121HygroEvtSen
1.3.6.1.4.1.28507.107.3.3 - epc1121LineAmperageEvt
1.3.6.1.4.1.28507.107.3.7 - epc1121LinePowerEvt
1.3.6.1.4.1.28507.107.3.27 - epc1121LineVoltageEvt
1.3.6.1.4.1.28507.107.3.26 - epc1121OVPEvt
1.3.6.1.4.1.28507.107.3.6 - epc1121SwitchEvtPort
1.3.6.1.4.1.28507.107.3.1 - epc1121TempEvtSen
1.3.6.1.4.1.28507.107.3.2