GIGAMON-SNMP-MIB
Gigamon Systems LLCTop-level infrastructure of Gigamon's MIB objects for GigaVUE-212, GigaVUE-420, GigaVUE-2404, GigaVUE-HD and GigaVUE-TA1
snmptranslate -m GIGAMON-SNMP-MIB -Tpsnmpwalk -v2c -c <community> -m GIGAMON-SNMP-MIB <host> 1.3.6.1.4.1.26866Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-MIB | sysLocation |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TimeStamp |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IgigamonSnmp | 1.3.6.1.4.1.26866 | ||||||||||||||||
identity Top-level infrastructure of Gigamon's MIB objects for GigaVUE-212, GigaVUE-420, GigaVUE-2404, GigaVUE-HD and GigaVUE-TA1 | |||||||||||||||||
| NgigamonSnmpNotifications | 1.3.6.1.4.1.26866.1 | ||||||||||||||||
| NgigamonGigaVUE | 1.3.6.1.4.1.26866.1.1 | ||||||||||||||||
| !gigamonSnmpResetSystemNotification | 1.3.6.1.4.1.26866.1.1.1 | ||||||||||||||||
notification · current System reset notification triggered by cold or warm start. | |||||||||||||||||
| !gigamonSnmpUserAuthFailNotification | 1.3.6.1.4.1.26866.1.1.2 | ||||||||||||||||
notification · current Failure in user login operation is the triggered Event. | |||||||||||||||||
| !gigamonSnmpFirmwareChangeNotification | 1.3.6.1.4.1.26866.1.1.3 | ||||||||||||||||
notification · current Firmware Change notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonSnmpConfigSaveNotification | 1.3.6.1.4.1.26866.1.1.4 | ||||||||||||||||
notification · current Config save notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonSnmpModuleChangeNotification | 1.3.6.1.4.1.26866.1.1.5 | ||||||||||||||||
notification · current GigaVUE HW module swapping is the triggered Event. | |||||||||||||||||
| !gigamonSnmpPacketDropNotification | 1.3.6.1.4.1.26866.1.1.6 | ||||||||||||||||
notification · current Packet Drop notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonSnmpTapRelayChangeNotification | 1.3.6.1.4.1.26866.1.1.7 | ||||||||||||||||
notification · current TAP relay change notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonSnmpPortLinkChangeNotification | 1.3.6.1.4.1.26866.1.1.8 | ||||||||||||||||
notification · current Port link status change notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonSnmpRxTxErrorNotification | 1.3.6.1.4.1.26866.1.1.9 | ||||||||||||||||
notification · current Packet receive/transmit error notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonPowerChangeNotification | 1.3.6.1.4.1.26866.1.1.10 | ||||||||||||||||
notification · current Power supply status change notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonFanChangeNotification | 1.3.6.1.4.1.26866.1.1.11 | ||||||||||||||||
notification · current Fan status change notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonSnmpOverThresholdChangeNotification | 1.3.6.1.4.1.26866.1.1.12 | ||||||||||||||||
notification · current Utilization alarm notification is the Edge/Level Triggered Event. | |||||||||||||||||
| !gigamonSnmpBatteryLevelChangeNotification | 1.3.6.1.4.1.26866.1.1.13 | ||||||||||||||||
notification · current Battery level down notification. | |||||||||||||||||
| !gigamonLinkSpeedStatusChangeNotification | 1.3.6.1.4.1.26866.1.1.14 | ||||||||||||||||
notification · current Link status or speed change notification. | |||||||||||||||||
| !gigamonPowerSourceChangeNotification | 1.3.6.1.4.1.26866.1.1.15 | ||||||||||||||||
notification · current Power source or status change notification. | |||||||||||||||||
| !gigamonSnmpCpuUtilHighNotification | 1.3.6.1.4.1.26866.1.1.16 | ||||||||||||||||
notification · current The average CPU utilization in the past minute has gone above the acceptable threshold | |||||||||||||||||
| !gigamonSnmpUnexpectedShutdownNotification | 1.3.6.1.4.1.26866.1.1.17 | ||||||||||||||||
notification · current The system has shut down unexpectedly | |||||||||||||||||
| !gigamonSnmpDiskSpaceLowNotification | 1.3.6.1.4.1.26866.1.1.18 | ||||||||||||||||
notification · current Free space in one of the filesystems is low | |||||||||||||||||
| !gigamonSnmpWatchdogResetNotification | 1.3.6.1.4.1.26866.1.1.19 | ||||||||||||||||
notification · current System reset notification triggered by watchdog timer. | |||||||||||||||||
| !gigamonSnmpBpsFailoverNotification | 1.3.6.1.4.1.26866.1.1.20 | ||||||||||||||||
notification · current Inline-bypass active unit change notification is the Edge/Level Triggered Event. | |||||||||||||||||
| NgigamonSnmpNotificationObjects | 1.3.6.1.4.1.26866.1.2 | ||||||||||||||||
| SgigamonSnmpNotifLevel | 1.3.6.1.4.1.26866.1.2.1 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It acts as a payload for the level of Gigamon's Notifications.
| |||||||||||||||||
| SgigamonSnmpNotifDescription | 1.3.6.1.4.1.26866.1.2.2 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current It acts as a payload for the description of Gigamon's Notifications. The value is to describe the reason for the notification. | |||||||||||||||||
| SgigamonSnmpNotifOpType | 1.3.6.1.4.1.26866.1.2.3 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It specifies the type of operation of Gigamon's Notifications.
| |||||||||||||||||
| SgigamonSnmpNotifPortName | 1.3.6.1.4.1.26866.1.2.4 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current The alpha-numerical name of a port shown in Gigamon's Notifications. | |||||||||||||||||
| SgigamonSnmpNotifPortLinkStatus | 1.3.6.1.4.1.26866.1.2.5 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It indicates port link status of Gigamon's Notifications.
| |||||||||||||||||
| SgigamonSnmpNotifTAPRelayStatus | 1.3.6.1.4.1.26866.1.2.6 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It indicates TAP relay status of Gigamon's Notifications.
| |||||||||||||||||
| SgigamonSnmpNotifRxTxType | 1.3.6.1.4.1.26866.1.2.7 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It indicates Incoming/RX or outgoing/TX packets
| |||||||||||||||||
| SgigamonSnmpNotifRxTxErrorType | 1.3.6.1.4.1.26866.1.2.8 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It indicates RX/TX error type of Gigamon's Notifications.
| |||||||||||||||||
| SgigamonSnmpNotifCounter | 1.3.6.1.4.1.26866.1.2.9 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current 32-bit Counter. | |||||||||||||||||
| SgigamonSnmpNotifFirmwareName | 1.3.6.1.4.1.26866.1.2.10 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current Name of GigaVUE firmware. | |||||||||||||||||
| SgigamonSnmpNotifModuleOperationType | 1.3.6.1.4.1.26866.1.2.11 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It indicates the operation performed on module
| |||||||||||||||||
| SgigamonSnmpNotifModuleName | 1.3.6.1.4.1.26866.1.2.12 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current Module name of GigaVUE module | |||||||||||||||||
| SgigamonNotifSlotNumber | 1.3.6.1.4.1.26866.1.2.13 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current Slot number
| |||||||||||||||||
| SgigamonSnmpNotifUserName | 1.3.6.1.4.1.26866.1.2.14 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current User login name typed in | |||||||||||||||||
| SgigamonSnmpNotifFileName | 1.3.6.1.4.1.26866.1.2.15 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current Saved configuration file name | |||||||||||||||||
| SgigamonNotifPowerStatus | 1.3.6.1.4.1.26866.1.2.16 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current Power Status
| |||||||||||||||||
| SgigamonSnmpNotifHardWareName | 1.3.6.1.4.1.26866.1.2.17 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current Description of Hardware | |||||||||||||||||
| SgigamonSnmpNotifGigaVUE420SlotNumber | 1.3.6.1.4.1.26866.1.2.18 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current Slot number
| |||||||||||||||||
| SgigamonSnmpNotifFanName | 1.3.6.1.4.1.26866.1.2.19 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current Name of fan | |||||||||||||||||
| SgigamonNotifFanStatus | 1.3.6.1.4.1.26866.1.2.20 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current Fan Status
| |||||||||||||||||
| SgigamonSnmpNotifUtilizationAlarm | 1.3.6.1.4.1.26866.1.2.21 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current It indicates over-threshold port utilization alarm of Gigamon's Notifications.
| |||||||||||||||||
| SgigamonSnmpNotifUtilizationThreshold | 1.3.6.1.4.1.26866.1.2.22 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current Utilization threshold percentage | |||||||||||||||||
| SgigamonSnmpBatteryLevel | 1.3.6.1.4.1.26866.1.2.23 | INTEGER | RO | ||||||||||||||
scalar · INTEGER · read-only · current battery level: 0 - battery charge complete 1 - battery level has been down below 75% 2 - battery level has been down below 50% 3 - battery level has been down below 25% 4 - battery level has down to 15% or below and shutting down the system
| |||||||||||||||||
| SgigamonSnmpPortLinkSpeed | 1.3.6.1.4.1.26866.1.2.24 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current port link speed: 0 - Not Apply if link is down 1 - 10 Mbps 2 - 100 Mbps 3 - 1000 Mbps 4 - 10000 Mbps 5 - 40000 Mbps 6 - 100000 Mbps
| |||||||||||||||||
| SgigamonSnmpPortLinkDuplex | 1.3.6.1.4.1.26866.1.2.25 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current port link duplex: 0 - Not Apply if link is down 1 - full duplex 2 - half duplex
| |||||||||||||||||
| SgigamonSnmpNotifCpuIndex | 1.3.6.1.4.1.26866.1.2.26 | Unsigned32 | AN | ||||||||||||||
scalar · Unsigned32 · accessible-for-notify · current Index of CPU, starting from 0 | |||||||||||||||||
| SgigamonSnmpNotifFsMountPoint | 1.3.6.1.4.1.26866.1.2.27 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current Mount point for this filesystem | |||||||||||||||||
| SgigamonSnmpPowerSource | 1.3.6.1.4.1.26866.1.2.28 | INTEGER | RO | ||||||||||||||
scalar · INTEGER · read-only · current power source: 0 - main power 1 - poe(Power over Ethernet) 2 - -48V Power
| |||||||||||||||||
| SgigamonSnmpNotifBpsUnitName | 1.3.6.1.4.1.26866.1.2.29 | OCTET STRING | AN | ||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current Name of BPS unit | |||||||||||||||||
| SgigamonSnmpNotifBpsFailoverStatus | 1.3.6.1.4.1.26866.1.2.30 | INTEGER | AN | ||||||||||||||
scalar · INTEGER · accessible-for-notify · current Inline-bypass active unit change
| |||||||||||||||||
| NgigamonSystem | 1.3.6.1.4.1.26866.2 | ||||||||||||||||
| Smanufacturer | 1.3.6.1.4.1.26866.2.1 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the manufacturer name of the system. | |||||||||||||||||
| Smodel | 1.3.6.1.4.1.26866.2.2 | OCTET STRING | RO | CHS-HC2 | |||||||||||||
scalar · OCTET STRING · read-only · current Displays the model name of the system. Example values from LibreNMS test devices
| |||||||||||||||||
| Sname | 1.3.6.1.4.1.26866.2.3 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the name of the system. | |||||||||||||||||
| SserialNumber | 1.3.6.1.4.1.26866.2.4 | OCTET STRING | RO | 21327 | |||||||||||||
scalar · OCTET STRING · read-only · current Displays the serial number of the system. Example values from LibreNMS test devices
| |||||||||||||||||
| SsystemDescription | 1.3.6.1.4.1.26866.2.5 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the description of the system. | |||||||||||||||||
| Sversion | 1.3.6.1.4.1.26866.2.6 | OCTET STRING | RO | v8.6.07 | |||||||||||||
scalar · OCTET STRING · read-only · current Displays the software version of the system. Example values from LibreNMS test devices
| |||||||||||||||||
| SchassisModelNumber | 1.3.6.1.4.1.26866.2.7 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the chassis model number of the system. | |||||||||||||||||
| SchassisSerialNumber | 1.3.6.1.4.1.26866.2.8 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the chassis serial number of the system. | |||||||||||||||||
| SbladeSerialNumbers | 1.3.6.1.4.1.26866.2.9 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the blade serial numbers in the system. | |||||||||||||||||
| SfirmwareVersion | 1.3.6.1.4.1.26866.2.10 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the firmware version of the system. | |||||||||||||||||
| ShardwareVersion | 1.3.6.1.4.1.26866.2.11 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the hardware version of the system. | |||||||||||||||||
| ScpuRAMSize | 1.3.6.1.4.1.26866.2.12 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the CPU RAM size of the system. | |||||||||||||||||
| ScpuUtilization | 1.3.6.1.4.1.26866.2.13 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the CPU utilization of the system. | |||||||||||||||||
| Sfans | 1.3.6.1.4.1.26866.2.14 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the fans in the system. | |||||||||||||||||
| StemperatureSensors | 1.3.6.1.4.1.26866.2.15 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the temperature sensors in the system. | |||||||||||||||||
| SpowerSupply | 1.3.6.1.4.1.26866.2.16 | OCTET STRING | RO | ||||||||||||||
scalar · OCTET STRING · read-only · current Displays the power supplies in the system. | |||||||||||||||||
| NgigamonProducts | 1.3.6.1.4.1.26866.3 | ||||||||||||||||
| NgigamonGV2404 | 1.3.6.1.4.1.26866.3.1 | ||||||||||||||||
| NgigamonGV420 | 1.3.6.1.4.1.26866.3.2 | ||||||||||||||||
| NgigamonGV212 | 1.3.6.1.4.1.26866.3.3 | ||||||||||||||||
| NgigamonGV216 | 1.3.6.1.4.1.26866.3.4 | ||||||||||||||||
Traps / Notifications
- gigamonFanChangeNotification
1.3.6.1.4.1.26866.1.1.11 - gigamonLinkSpeedStatusChangeNotification
1.3.6.1.4.1.26866.1.1.14 - gigamonPowerChangeNotification
1.3.6.1.4.1.26866.1.1.10 - gigamonPowerSourceChangeNotification
1.3.6.1.4.1.26866.1.1.15 - gigamonSnmpBatteryLevelChangeNotification
1.3.6.1.4.1.26866.1.1.13 - gigamonSnmpBpsFailoverNotification
1.3.6.1.4.1.26866.1.1.20 - gigamonSnmpConfigSaveNotification
1.3.6.1.4.1.26866.1.1.4 - gigamonSnmpCpuUtilHighNotification
1.3.6.1.4.1.26866.1.1.16 - gigamonSnmpDiskSpaceLowNotification
1.3.6.1.4.1.26866.1.1.18 - gigamonSnmpFirmwareChangeNotification
1.3.6.1.4.1.26866.1.1.3 - gigamonSnmpModuleChangeNotification
1.3.6.1.4.1.26866.1.1.5 - gigamonSnmpOverThresholdChangeNotification
1.3.6.1.4.1.26866.1.1.12 - gigamonSnmpPacketDropNotification
1.3.6.1.4.1.26866.1.1.6 - gigamonSnmpPortLinkChangeNotification
1.3.6.1.4.1.26866.1.1.8 - gigamonSnmpResetSystemNotification
1.3.6.1.4.1.26866.1.1.1 - gigamonSnmpRxTxErrorNotification
1.3.6.1.4.1.26866.1.1.9 - gigamonSnmpTapRelayChangeNotification
1.3.6.1.4.1.26866.1.1.7 - gigamonSnmpUnexpectedShutdownNotification
1.3.6.1.4.1.26866.1.1.17 - gigamonSnmpUserAuthFailNotification
1.3.6.1.4.1.26866.1.1.2 - gigamonSnmpWatchdogResetNotification
1.3.6.1.4.1.26866.1.1.19