FORTINET-FORTISWITCH-MIB
Fortinet, Inc.MIB module for Fortinet FortiSwitch devices.
snmptranslate -m FORTINET-FORTISWITCH-MIB -Tpsnmpwalk -v2c -c <community> -m FORTINET-FORTISWITCH-MIB <host> 1.3.6.1.4.1.12356.106Imports
| BRIDGE-MIB | dot1dTpFdbAddress, dot1dTpFdbPort |
|---|---|
| FORTINET-CORE-MIB | fnSysSerial, fortinet |
| IF-MIB | ifName |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-MIB | sysName |
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IfnFortiSwitchMib | 1.3.6.1.4.1.12356.106 | ||||||||||||||||||||
identity MIB module for Fortinet FortiSwitch devices. | |||||||||||||||||||||
| NfsCommon | 1.3.6.1.4.1.12356.106.1 | ||||||||||||||||||||
| NfsSys | 1.3.6.1.4.1.12356.106.1.1 | ||||||||||||||||||||
| SfsSysSerial | 1.3.6.1.4.1.12356.106.1.1.1 | DisplayString | RO | ||||||||||||||||||
scalar · DisplayString · read-only · current Device serial number. This is the same serial number as given in the ENTITY-MIB tables for the base entity. | |||||||||||||||||||||
| NfsTraps | 1.3.6.1.4.1.12356.106.2 | ||||||||||||||||||||
| NfsTrapPrefix | 1.3.6.1.4.1.12356.106.2.0 | ||||||||||||||||||||
| !fsTrapMemberDown | 1.3.6.1.4.1.12356.106.2.0.703 | ||||||||||||||||||||
| !fsTrapMemberUp | 1.3.6.1.4.1.12356.106.2.0.704 | ||||||||||||||||||||
notification · current A trunk member has joined this trunk
| |||||||||||||||||||||
| !fsTrapLlvViolation | 1.3.6.1.4.1.12356.106.2.0.705 | ||||||||||||||||||||
notification · current Trap messages for learning limit violations.
| |||||||||||||||||||||
| !fsTrapLearningEvent | 1.3.6.1.4.1.12356.106.2.0.706 | ||||||||||||||||||||
notification · current A new MAC address learning event occurred (add/delete/move). | |||||||||||||||||||||
| !fsTrapSensorFault | 1.3.6.1.4.1.12356.106.2.0.707 | ||||||||||||||||||||
notification · current Trap message indicates that a faulty sensor was detected.
| |||||||||||||||||||||
| !fsTrapSensorAlarm | 1.3.6.1.4.1.12356.106.2.0.708 | ||||||||||||||||||||
notification · current Trap messages for temperature, PoE, CPU, memory, and disk sensor alarms. | |||||||||||||||||||||
| !fsTrapFanDetect | 1.3.6.1.4.1.12356.106.2.0.709 | ||||||||||||||||||||
notification · current Trap message associated with fan sensor detection.
| |||||||||||||||||||||
| !fsTrapPsuStatus | 1.3.6.1.4.1.12356.106.2.0.710 | ||||||||||||||||||||
notification · current Trap message associated with PSU status changes.
| |||||||||||||||||||||
| !fsTrapStormControl | 1.3.6.1.4.1.12356.106.2.0.711 | ||||||||||||||||||||
notification · current Trap message indicates a storm-control status change (drop start/stop).
| |||||||||||||||||||||
| !fsTrapIpConflict | 1.3.6.1.4.1.12356.106.2.0.801 | ||||||||||||||||||||
notification · current Trap message associated with IP Conflict Detection.
| |||||||||||||||||||||
| !fsTrapTrunkMemberHBOutOfSync | 1.3.6.1.4.1.12356.106.2.0.802 | ||||||||||||||||||||
notification · current Trap message indicates a trunk member HB is out of sync (trunk = ifName1, member = ifName2).
| |||||||||||||||||||||
| !fsTrapStitch1 | 1.3.6.1.4.1.12356.106.2.0.901 | ||||||||||||||||||||
notification · current Custom SNMP trap triggerable from automation stitch.
| |||||||||||||||||||||
| !fsTrapStitch2 | 1.3.6.1.4.1.12356.106.2.0.902 | ||||||||||||||||||||
notification · current Custom SNMP trap triggerable from automation stitch.
| |||||||||||||||||||||
| !fsTrapStitch3 | 1.3.6.1.4.1.12356.106.2.0.903 | ||||||||||||||||||||
notification · current Custom SNMP trap triggerable from automation stitch.
| |||||||||||||||||||||
| !fsTrapStitch4 | 1.3.6.1.4.1.12356.106.2.0.904 | ||||||||||||||||||||
notification · current Custom SNMP trap triggerable from automation stitch.
| |||||||||||||||||||||
| !fsTrapStitch5 | 1.3.6.1.4.1.12356.106.2.0.905 | ||||||||||||||||||||
notification · current Custom SNMP trap triggerable from automation stitch.
| |||||||||||||||||||||
| NfsTrapObjects | 1.3.6.1.4.1.12356.106.2.1 | ||||||||||||||||||||
| SfsLlvTrapMsg | 1.3.6.1.4.1.12356.106.2.1.1 | DisplayString | AN | ||||||||||||||||||
scalar · DisplayString · accessible-for-notify · current Message associated with a learning limit violation. | |||||||||||||||||||||
| SfsLearningTrapVid | 1.3.6.1.4.1.12356.106.2.1.2 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current VLAN ID associated with a MAC learning event. | |||||||||||||||||||||
| SfsLearningTrapType | 1.3.6.1.4.1.12356.106.2.1.3 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Type associated with a MAC learning event (add/delete/movefrom/moveto).
| |||||||||||||||||||||
| SfsSensorName | 1.3.6.1.4.1.12356.106.2.1.4 | DisplayString | AN | ||||||||||||||||||
scalar · DisplayString · accessible-for-notify · current Name of the sensor associated with a trap message. | |||||||||||||||||||||
| SfsSensorType | 1.3.6.1.4.1.12356.106.2.1.5 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Type of sensor associated with a trap message (temperature/PoE/CPU/memory/disk).
| |||||||||||||||||||||
| SfsSensorIdx | 1.3.6.1.4.1.12356.106.2.1.6 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Index of the sensor associated with a trap message. | |||||||||||||||||||||
| SfsSensorFanEventType | 1.3.6.1.4.1.12356.106.2.1.7 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Type of event associated with the fan trap message (detected/undetected/resumed/failure).
| |||||||||||||||||||||
| SfsSensorPsuEventType | 1.3.6.1.4.1.12356.106.2.1.8 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Type of event associated with the PSU trap message (up/connected/good/down/disconnected/bad).
| |||||||||||||||||||||
| SfsAlarmEventType | 1.3.6.1.4.1.12356.106.2.1.9 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Type of event associated with the alarm trap message (inrange/warning/outofrange/cleared).
| |||||||||||||||||||||
| SfsAlarmThresholdValue | 1.3.6.1.4.1.12356.106.2.1.10 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Threshold value. | |||||||||||||||||||||
| SfsAlarmThresholdUnits | 1.3.6.1.4.1.12356.106.2.1.11 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current Type of units associated with this threshold value (celcius/watts/percentage/unknown).
| |||||||||||||||||||||
| SfsIpAddress | 1.3.6.1.4.1.12356.106.2.1.12 | IpAddress | AN | ||||||||||||||||||
scalar · IpAddress · accessible-for-notify · current IP address associated with a trap message (e.g. IP Conflict). | |||||||||||||||||||||
| SfsJsonString | 1.3.6.1.4.1.12356.106.2.1.13 | OCTET STRING (SIZE (0..1360)) | AN | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..1360)) · accessible-for-notify · current JSON string associated with an automation-generated trap message. | |||||||||||||||||||||
| SfsSwitchStormContrl | 1.3.6.1.4.1.12356.106.2.1.14 | DisplayString | RO | ||||||||||||||||||
scalar · DisplayString · read-only · current Storm control status. | |||||||||||||||||||||
| NfsTrunkMemPrefix | 1.3.6.1.4.1.12356.106.3 | ||||||||||||||||||||
| SfsTrunkMember | 1.3.6.1.4.1.12356.106.3.1 | DisplayString (SIZE (0..82)) | RO | ||||||||||||||||||
scalar · DisplayString (SIZE (0..82)) · read-only · current Trunk members of the device, including this trunk member's corresponding blade's serial number and its slot name | |||||||||||||||||||||
| NfsSystem | 1.3.6.1.4.1.12356.106.4 | ||||||||||||||||||||
| NfsSystemInfo | 1.3.6.1.4.1.12356.106.4.1 | ||||||||||||||||||||
| SfsSysVersion | 1.3.6.1.4.1.12356.106.4.1.1 | DisplayString (SIZE (0..128)) | RO | FortiSwitch-248D-FPOE v3.3.3,build4047,160219 (… | |||||||||||||||||
scalar · DisplayString (SIZE (0..128)) · read-only · current Firmware version of the device Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfsSysCpuUsage | 1.3.6.1.4.1.12356.106.4.1.2 | Gauge32 (0..100) | RO | 42 | |||||||||||||||||
scalar · Gauge32 (0..100) · read-only · current Current CPU usage (percentage) Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfsSysMemUsage | 1.3.6.1.4.1.12356.106.4.1.3 | Gauge32 | RO | 234254 | |||||||||||||||||
scalar · Gauge32 · read-only · current Current system memory usage (KB) Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfsSysMemCapacity | 1.3.6.1.4.1.12356.106.4.1.4 | Gauge32 | RO | 1048576 | |||||||||||||||||
scalar · Gauge32 · read-only · current Total physical memory (RAM) installed (KB) Example values from LibreNMS test devices
| |||||||||||||||||||||
| SfsSysDiskUsage | 1.3.6.1.4.1.12356.106.4.1.5 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Current hard disk usage (KB), if disk is present | |||||||||||||||||||||
| SfsSysDiskCapacity | 1.3.6.1.4.1.12356.106.4.1.6 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Total hard disk capacity (KB), if disk is present | |||||||||||||||||||||
| NfsModel | 1.3.6.1.4.1.12356.106.5 | ||||||||||||||||||||
| Nfs24vm | 1.3.6.1.4.1.12356.106.5.241 | ||||||||||||||||||||
| Nfs108d | 1.3.6.1.4.1.12356.106.5.1081 | ||||||||||||||||||||
| Ns108en | 1.3.6.1.4.1.12356.106.5.1082 | ||||||||||||||||||||
| Ns108ep | 1.3.6.1.4.1.12356.106.5.1083 | ||||||||||||||||||||
| Ns108ef | 1.3.6.1.4.1.12356.106.5.1084 | ||||||||||||||||||||
| Ns108dv | 1.3.6.1.4.1.12356.106.5.1085 | ||||||||||||||||||||
| Ns108fn | 1.3.6.1.4.1.12356.106.5.1086 | ||||||||||||||||||||
| Ns108fp | 1.3.6.1.4.1.12356.106.5.1087 | ||||||||||||||||||||
| Ns108ff | 1.3.6.1.4.1.12356.106.5.1088 | ||||||||||||||||||||
| Nsm10gf | 1.3.6.1.4.1.12356.106.5.1102 | ||||||||||||||||||||
| Nsr12dp | 1.3.6.1.4.1.12356.106.5.1121 | ||||||||||||||||||||
| Ns124dn | 1.3.6.1.4.1.12356.106.5.1241 | ||||||||||||||||||||
| Ns124dp | 1.3.6.1.4.1.12356.106.5.1242 | ||||||||||||||||||||
| Nsr24dn | 1.3.6.1.4.1.12356.106.5.1243 | ||||||||||||||||||||
| Ns124en | 1.3.6.1.4.1.12356.106.5.1244 | ||||||||||||||||||||
| Ns124ep | 1.3.6.1.4.1.12356.106.5.1245 | ||||||||||||||||||||
| Ns124ef | 1.3.6.1.4.1.12356.106.5.1246 | ||||||||||||||||||||
| Ns148en | 1.3.6.1.4.1.12356.106.5.1247 | ||||||||||||||||||||
| Ns148ep | 1.3.6.1.4.1.12356.106.5.1248 | ||||||||||||||||||||
| Ns124ff | 1.3.6.1.4.1.12356.106.5.1249 | ||||||||||||||||||||
| Ns148fn | 1.3.6.1.4.1.12356.106.5.1484 | ||||||||||||||||||||
| Ns148fp | 1.3.6.1.4.1.12356.106.5.1485 | ||||||||||||||||||||
| Ns148ff | 1.3.6.1.4.1.12356.106.5.1486 | ||||||||||||||||||||
| Nsr16fp | 1.3.6.1.4.1.12356.106.5.2161 | ||||||||||||||||||||
| Nfs224d | 1.3.6.1.4.1.12356.106.5.2241 | ||||||||||||||||||||
| Ns224df | 1.3.6.1.4.1.12356.106.5.2242 | ||||||||||||||||||||
| Ns224en | 1.3.6.1.4.1.12356.106.5.2243 | ||||||||||||||||||||
| Ns224ep | 1.3.6.1.4.1.12356.106.5.2244 | ||||||||||||||||||||
| Ns248dp | 1.3.6.1.4.1.12356.106.5.2481 | ||||||||||||||||||||
| Ns248df | 1.3.6.1.4.1.12356.106.5.2482 | ||||||||||||||||||||
| Ns248dn | 1.3.6.1.4.1.12356.106.5.2483 | ||||||||||||||||||||
| Ns248ef | 1.3.6.1.4.1.12356.106.5.2484 | ||||||||||||||||||||
| Ns248ep | 1.3.6.1.4.1.12356.106.5.2485 | ||||||||||||||||||||
| Ns424dn | 1.3.6.1.4.1.12356.106.5.4241 | ||||||||||||||||||||
| Ns424dp | 1.3.6.1.4.1.12356.106.5.4242 | ||||||||||||||||||||
| Ns424df | 1.3.6.1.4.1.12356.106.5.4243 | ||||||||||||||||||||
| Ns448dn | 1.3.6.1.4.1.12356.106.5.4482 | ||||||||||||||||||||
| Ns448df | 1.3.6.1.4.1.12356.106.5.4483 | ||||||||||||||||||||
| Ns448dp | 1.3.6.1.4.1.12356.106.5.4484 | ||||||||||||||||||||
| Ns448en | 1.3.6.1.4.1.12356.106.5.4485 | ||||||||||||||||||||
| Ns448ep | 1.3.6.1.4.1.12356.106.5.4486 | ||||||||||||||||||||
| Ns448ef | 1.3.6.1.4.1.12356.106.5.4487 | ||||||||||||||||||||
| Ns524df | 1.3.6.1.4.1.12356.106.5.5241 | ||||||||||||||||||||
| Ns524dn | 1.3.6.1.4.1.12356.106.5.5242 | ||||||||||||||||||||
| Ns548df | 1.3.6.1.4.1.12356.106.5.5481 | ||||||||||||||||||||
| Ns548dn | 1.3.6.1.4.1.12356.106.5.5482 | ||||||||||||||||||||
| Ns624fn | 1.3.6.1.4.1.12356.106.5.6241 | ||||||||||||||||||||
| Ns624ff | 1.3.6.1.4.1.12356.106.5.6242 | ||||||||||||||||||||
| Ns648fn | 1.3.6.1.4.1.12356.106.5.6481 | ||||||||||||||||||||
| Ns648ff | 1.3.6.1.4.1.12356.106.5.6482 | ||||||||||||||||||||
| Nfs1d24 | 1.3.6.1.4.1.12356.106.5.10241 | ||||||||||||||||||||
| Nfs1e24 | 1.3.6.1.4.1.12356.106.5.10242 | ||||||||||||||||||||
| Nst1e24 | 1.3.6.1.4.1.12356.106.5.10243 | ||||||||||||||||||||
| Ntf1f24 | 1.3.6.1.4.1.12356.106.5.10244 | ||||||||||||||||||||
| Nfs1d48 | 1.3.6.1.4.1.12356.106.5.10481 | ||||||||||||||||||||
| Nfs1e48 | 1.3.6.1.4.1.12356.106.5.10482 | ||||||||||||||||||||
| Ns124fn | 1.3.6.1.4.1.12356.106.5.12410 | ||||||||||||||||||||
| Ns124fp | 1.3.6.1.4.1.12356.106.5.12411 | ||||||||||||||||||||
| Nsm24gn | 1.3.6.1.4.1.12356.106.5.12412 | ||||||||||||||||||||
| Nsm24gf | 1.3.6.1.4.1.12356.106.5.12413 | ||||||||||||||||||||
| Nfs2f48 | 1.3.6.1.4.1.12356.106.5.20481 | ||||||||||||||||||||
| Nfs3d32 | 1.3.6.1.4.1.12356.106.5.30321 | ||||||||||||||||||||
| Nfs3e32 | 1.3.6.1.4.1.12356.106.5.30322 | ||||||||||||||||||||
| Ns424en | 1.3.6.1.4.1.12356.106.5.42401 | ||||||||||||||||||||
| Ns424ep | 1.3.6.1.4.1.12356.106.5.42402 | ||||||||||||||||||||
| Ns424ef | 1.3.6.1.4.1.12356.106.5.42403 | ||||||||||||||||||||
| Ns424ei | 1.3.6.1.4.1.12356.106.5.42404 | ||||||||||||||||||||
| Ns426ef | 1.3.6.1.4.1.12356.106.5.42405 | ||||||||||||||||||||
| Nsr24fp | 1.3.6.1.4.1.12356.106.5.42406 | ||||||||||||||||||||
| NfsMibConformance | 1.3.6.1.4.1.12356.106.100 | ||||||||||||||||||||
| GfsNotificationGroup | 1.3.6.1.4.1.12356.106.100.1 | ||||||||||||||||||||
group · current Notifications that can be generated from a FortiSwitch device.
| |||||||||||||||||||||
| GfsSystemObjectGroup | 1.3.6.1.4.1.12356.106.100.2 | ||||||||||||||||||||
group · current Objects pertaining to the system status of the device. | |||||||||||||||||||||
| GfsTrunkObjectGroup | 1.3.6.1.4.1.12356.106.100.3 | ||||||||||||||||||||
| MfsMIBCompliance | 1.3.6.1.4.1.12356.106.100.100 | ||||||||||||||||||||
compliance · current The compliance statement for the application MIB. | |||||||||||||||||||||
Traps / Notifications
- fsTrapFanDetect
1.3.6.1.4.1.12356.106.2.0.709 - fsTrapIpConflict
1.3.6.1.4.1.12356.106.2.0.801 - fsTrapLearningEvent
1.3.6.1.4.1.12356.106.2.0.706 - fsTrapLlvViolation
1.3.6.1.4.1.12356.106.2.0.705 - fsTrapMemberDown
1.3.6.1.4.1.12356.106.2.0.703 - fsTrapMemberUp
1.3.6.1.4.1.12356.106.2.0.704 - fsTrapPsuStatus
1.3.6.1.4.1.12356.106.2.0.710 - fsTrapSensorAlarm
1.3.6.1.4.1.12356.106.2.0.708 - fsTrapSensorFault
1.3.6.1.4.1.12356.106.2.0.707 - fsTrapStitch1
1.3.6.1.4.1.12356.106.2.0.901 - fsTrapStitch2
1.3.6.1.4.1.12356.106.2.0.902 - fsTrapStitch3
1.3.6.1.4.1.12356.106.2.0.903 - fsTrapStitch4
1.3.6.1.4.1.12356.106.2.0.904 - fsTrapStitch5
1.3.6.1.4.1.12356.106.2.0.905 - fsTrapStormControl
1.3.6.1.4.1.12356.106.2.0.711 - fsTrapTrunkMemberHBOutOfSync
1.3.6.1.4.1.12356.106.2.0.802