FIBROLAN-SFP-MIB
FibrolanThe MIB module to describe Fibrolan SFP devices. Copyright (C) Fibrolan Ltd (2014).
snmptranslate -m FIBROLAN-SFP-MIB -Tpsnmpwalk -v2c -c <community> -m FIBROLAN-SFP-MIB <host> 1.3.6.1.4.1.4467.1000.50Imports
| FIBROLAN-COMMON-MIB | fibrolanGeneric |
|---|---|
| FIBROLAN-DEVICE-MIB | flDeviceNotifications |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TimeStamp |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| !flSfpPluggedIn | 1.3.6.1.4.1.4467.1000.10.0.17 | ||||||||||||||||||||
notification · current This trap is sent when an SFP module is plugged in the device. This trap is left here for backward compatibility reasons. In newer SW versions the flSfpAlarmStatusChange trap should be used instead. | |||||||||||||||||||||
| !flSfpUnplugged | 1.3.6.1.4.1.4467.1000.10.0.18 | ||||||||||||||||||||
notification · current This trap is sent when an SFP module is unplugged from the device. This trap is left here for backward compatibility reasons. In newer SW versions the flSfpAlarmStatusChange trap should be used instead. | |||||||||||||||||||||
| IflSfp | 1.3.6.1.4.1.4467.1000.50 | ||||||||||||||||||||
identity The MIB module to describe Fibrolan SFP devices. Copyright (C) Fibrolan Ltd (2014). | |||||||||||||||||||||
| NflSfpMIBObjects | 1.3.6.1.4.1.4467.1000.50.1 | ||||||||||||||||||||
| TflSfpInfoTable | 1.3.6.1.4.1.4467.1000.50.1.1 | NA | |||||||||||||||||||
table · not-accessible · current Table for SFP inventory data | |||||||||||||||||||||
| RflSfpInfoEntry | 1.3.6.1.4.1.4467.1000.50.1.1.1 | NA | |||||||||||||||||||
| CflSfpVendor | 1.3.6.1.4.1.4467.1000.50.1.1.1.1 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current SFP's vendor | |||||||||||||||||||||
| CflSfpPartNumber | 1.3.6.1.4.1.4467.1000.50.1.1.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current SFP's part number | |||||||||||||||||||||
| CflSfpSerialNumber | 1.3.6.1.4.1.4467.1000.50.1.1.1.3 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current SFP's serial number | |||||||||||||||||||||
| CflSfpType | 1.3.6.1.4.1.4467.1000.50.1.1.1.4 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current SFP module type (textual description) | |||||||||||||||||||||
| CflSfpMaxRate | 1.3.6.1.4.1.4467.1000.50.1.1.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current SFP's nominal bit rate in Mbps. | |||||||||||||||||||||
| CflSfpRange | 1.3.6.1.4.1.4467.1000.50.1.1.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current SFP's nominal range in meters. | |||||||||||||||||||||
| CflSfpTxWl | 1.3.6.1.4.1.4467.1000.50.1.1.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current SFP's transmit wave-length in nano-meters (integer part). The complete wavelength can be calculated with the flSfpTxWlFraction. In DWDM SFPs, the integer part of the WL is used here. for example: 1572.89nm (ch6/100GHz) will be provided as 1572. | |||||||||||||||||||||
| CflSfpTxWlFraction | 1.3.6.1.4.1.4467.1000.50.1.1.1.8 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current SFP's transmit wave-length in pico-meters (fraction part). The complete wavelength can be calculated with the flSfpTxWl. In DWDM SFPs, the fraction part of the WL is used here. for example: 1572.89nm (ch6/100GHz) will be provided as 890 | |||||||||||||||||||||
| CflSfpRxWl | 1.3.6.1.4.1.4467.1000.50.1.1.1.9 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current SFP's receive wave-length in nano-meters (integer part). The complete wavelength can be calculated with the flSfpRxWlFraction. In DWDM SFPs, the integer part of the WL is used here. for example: 1572.89nm (ch6/100GHz) will be provided as 1572. | |||||||||||||||||||||
| CflSfpRxWlFraction | 1.3.6.1.4.1.4467.1000.50.1.1.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current SFP's receive wave-length in pico-meters (fraction part). The complete wavelength can be calculated with the flSfpTxWl. In DWDM SFPs, the fraction part of the WL is used here. for example: 1572.89nm (ch6/100GHz) will be provided as 890 | |||||||||||||||||||||
| CflSfpDdmSupport | 1.3.6.1.4.1.4467.1000.50.1.1.1.11 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates if this SFP supports DDM (as per SFF-8472).
| |||||||||||||||||||||
| TflSfpMonitoringTable | 1.3.6.1.4.1.4467.1000.50.1.2 | NA | |||||||||||||||||||
table · not-accessible · current Table for SFP monitoring (digital diagnostics) data | |||||||||||||||||||||
| RflSfpMonitoringEntry | 1.3.6.1.4.1.4467.1000.50.1.2.1 | NA | |||||||||||||||||||
| CflSfpRxPower | 1.3.6.1.4.1.4467.1000.50.1.2.1.1 | Integer32 | RO | 1089 | |||||||||||||||||
column · Integer32 · read-only · current Received average optical power in [uW]
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflSfpTxPower | 1.3.6.1.4.1.4467.1000.50.1.2.1.2 | Integer32 | RO | 628 | |||||||||||||||||
column · Integer32 · read-only · current Transmitted average optical power in [uW]
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflSfpTemperature | 1.3.6.1.4.1.4467.1000.50.1.2.1.3 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Device temperature in [oC]
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflSfpBiasCurrent | 1.3.6.1.4.1.4467.1000.50.1.2.1.4 | Integer32 | RO | 50 | |||||||||||||||||
column · Integer32 · read-only · current Transmitter bias current in [mA]
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflSfpSupplyVoltage | 1.3.6.1.4.1.4467.1000.50.1.2.1.5 | Integer32 | RO | 222 | |||||||||||||||||
column · Integer32 · read-only · current Internal supply voltage in [mV]
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflSfpAlarmStatus | 1.3.6.1.4.1.4467.1000.50.1.2.1.6 | Integer32 (1..255) | RO | 282884 | |||||||||||||||||
column · Integer32 (1..255) · read-only · current This variable indicates the SFP alarm status. The flSfpAlarmStatus is a bitmap represented as a sum; therefore, it can represent multiple status (alarms) simultaneously. flSfpNoAlarm must be set if and only if no other flag is set. The various bit positions are as follows: 0 flSfpNoAlarm No alarm present 1 flSfpUnplugged SFP module unplugged 2 flSfpTxPowerLowError Optical Tx power below error threshold 3 flSfpTxPowerLowWarning Optical Tx power below warning threshold 4 flSfpRxPowerLowError Optical Rx power below error threshold 5 flSfpRxPowerLowWarning Optical Rx power below warning threshold 6 flSfpTxPowerHighError Optical Tx power above error threshold 7 flSfpTxPowerHighWarning Optical Tx power above warning threshold 8 flSfpRxPowerHighError Optical Rx power above error threshold 9 flSfpRxPowerHighWarning Optical Rx power above warning threshold 10 flSfpTempHighError Module temp. above error threshold 11 flSfpTempHighWarning Module temp. above warning threshold 12 flSfpTempLowError Module temp. below error threshold 13 flSfpTempLowWarning Module temp. below warning threshold Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflSfpStatusLastChange | 1.3.6.1.4.1.4467.1000.50.1.2.1.7 | TimeStamp | RO | 0 (0d 0h 0m 0s) | |||||||||||||||||
column · TimeStamp · read-only · current The value of MIB II's sysUpTime object at the time this SFP entered its current alarm status state. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NflSfpMIBConformance | 1.3.6.1.4.1.4467.1000.50.2 | ||||||||||||||||||||
| NflSfpMIBCompliances | 1.3.6.1.4.1.4467.1000.50.2.1 | ||||||||||||||||||||
| MflSfpMIBCompliance | 1.3.6.1.4.1.4467.1000.50.2.1.1 | ||||||||||||||||||||
compliance · current The compliance statement for flSfp entities | |||||||||||||||||||||
| NflSfpMIBGroups | 1.3.6.1.4.1.4467.1000.50.2.2 | ||||||||||||||||||||
| GflSfpDeviceGroup | 1.3.6.1.4.1.4467.1000.50.2.2.1 | ||||||||||||||||||||
group · current SFP standard status objects. | |||||||||||||||||||||
| GflSfpMonitoringGroup | 1.3.6.1.4.1.4467.1000.50.2.2.2 | ||||||||||||||||||||
group · current SFP monitoring (digital diagnostics) group. | |||||||||||||||||||||
| GflSfpNotificationsGroup | 1.3.6.1.4.1.4467.1000.50.2.2.3 | ||||||||||||||||||||
group · current A collection of notifications that may be implemented on SFP modules.
| |||||||||||||||||||||
| NflSfpTraps | 1.3.6.1.4.1.4467.1000.50.10 | ||||||||||||||||||||
| !flSfpAlarmStatusChange | 1.3.6.1.4.1.4467.1000.50.10.0.1 | ||||||||||||||||||||
notification · current A flSfpAlarmStatusChange trap is sent when the value of an instance flSfpAlarmStatus changes. It can be utilized by an Network Management Station (NMS) to trigger polls. | |||||||||||||||||||||
Traps / Notifications
- flSfpAlarmStatusChange
1.3.6.1.4.1.4467.1000.50.10.0.1 - flSfpPluggedIn
1.3.6.1.4.1.4467.1000.10.0.17 - flSfpUnplugged
1.3.6.1.4.1.4467.1000.10.0.18