FIBROLAN-MIB-SFP
FibrolanThe MIB module to describe FibroLAN SFP device. Copyright (C) Fibrolan Ltd (2008).
snmptranslate -m FIBROLAN-MIB-SFP -Tpsnmpwalk -v2c -c <community> -m FIBROLAN-MIB-SFP <host> 1.3.6.1.4.1.4467.100.500.100Imports
| FIBROLAN-MIB-METRO-STAR-MV | flMsChassisModuleMvIndex, flMsChassisMvIndex |
|---|---|
| FIBROLAN-MIB-MSMODULE | flMsModuleMvChannelIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Nfibrolan | 1.3.6.1.4.1.4467 | |||
| NfibrolanSNMP | 1.3.6.1.4.1.4467.100 | |||
| NflMetroStarMv | 1.3.6.1.4.1.4467.100.500 | |||
| IflSfp | 1.3.6.1.4.1.4467.100.500.100 | |||
identity The MIB module to describe FibroLAN SFP device. Copyright (C) Fibrolan Ltd (2008). | ||||
| NflSfpMIBConformance | 1.3.6.1.4.1.4467.100.500.100.1 | |||
| NflSfpMIBCompliances | 1.3.6.1.4.1.4467.100.500.100.1.1 | |||
| MflSfpMIBCompliance | 1.3.6.1.4.1.4467.100.500.100.1.1.1 | |||
compliance · current The compliance statement for flSfp entities | ||||
| NflSfpMIBGroups | 1.3.6.1.4.1.4467.100.500.100.1.2 | |||
| GflSfpDeviceGroup | 1.3.6.1.4.1.4467.100.500.100.1.2.1 | |||
group · current SFP standard status objects. | ||||
| GflSfpPortsGroup | 1.3.6.1.4.1.4467.100.500.100.1.2.2 | |||
group · current SFP port status and configuration objects | ||||
| GflSfpMonitoringGroup | 1.3.6.1.4.1.4467.100.500.100.1.2.3 | |||
group · current SFP monitoring (digital diagnostics) group. | ||||
| NflSfpDevice | 1.3.6.1.4.1.4467.100.500.100.10 | |||
| TflSfpDeviceTable | 1.3.6.1.4.1.4467.100.500.100.10.1 | NA | ||
table · not-accessible · current Table for managing device level parameters | ||||
| RflSfpDeviceEntry | 1.3.6.1.4.1.4467.100.500.100.10.1.1 | NA | ||
row · not-accessible · current The entries of the table. | ||||
| CflSfpDevicePortIndex | 1.3.6.1.4.1.4467.100.500.100.10.1.1.1 | INTEGER (1..2) | RO | |
column · INTEGER (1..2) · read-only · current Sfp port index | ||||
| CflSfpDeviceLocalRemoteIndex | 1.3.6.1.4.1.4467.100.500.100.10.1.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current Remote/Local device indicator
| ||||
| CflSfpDeviceRemoteChannelIndex | 1.3.6.1.4.1.4467.100.500.100.10.1.1.3 | INTEGER (1..2) | RO | |
column · INTEGER (1..2) · read-only · current Sfp remote channel index | ||||
| CflSfpDeviceRemotePortIndex | 1.3.6.1.4.1.4467.100.500.100.10.1.1.4 | INTEGER (1..2) | RO | |
column · INTEGER (1..2) · read-only · current Sfp remote port index | ||||
| CflSfpDeviceSerialNumber | 1.3.6.1.4.1.4467.100.500.100.10.1.1.5 | DisplayString | RO | |
column · DisplayString · read-only · current Device's serial number | ||||
| CflSfpDevicePartNumber | 1.3.6.1.4.1.4467.100.500.100.10.1.1.6 | DisplayString | RO | |
column · DisplayString · read-only · current Device's part number | ||||
| CflSfpDevicePortName | 1.3.6.1.4.1.4467.100.500.100.10.1.1.7 | DisplayString | RO | |
column · DisplayString · read-only · current Device's port name | ||||
| CflSfpDeviceType | 1.3.6.1.4.1.4467.100.500.100.10.1.1.8 | DisplayString | RO | |
column · DisplayString · read-only · current Device's type | ||||
| CflSfpDeviceRange | 1.3.6.1.4.1.4467.100.500.100.10.1.1.9 | INTEGER | RO | |
column · INTEGER · read-only · current Device's range in meters | ||||
| CflSfpDeviceTxWl | 1.3.6.1.4.1.4467.100.500.100.10.1.1.10 | INTEGER | RO | |
column · INTEGER · read-only · current Device's Tx wave-length in nano-meters | ||||
| CflSfpDeviceRxwl | 1.3.6.1.4.1.4467.100.500.100.10.1.1.11 | INTEGER | RO | |
column · INTEGER · read-only · current Device's Rx wave-length in nano-meters | ||||
| CflSfpDeviceState | 1.3.6.1.4.1.4467.100.500.100.10.1.1.12 | INTEGER | RO | |
column · INTEGER · read-only · current Device's state
| ||||
| TflSfpPortsTable | 1.3.6.1.4.1.4467.100.500.100.10.2 | NA | ||
table · not-accessible · current Table for managing ports level parameters | ||||
| RflSfpPortsEntry | 1.3.6.1.4.1.4467.100.500.100.10.2.1 | NA | ||
row · not-accessible · current The entries of the table. | ||||
| CflSfpPortSignalDetect | 1.3.6.1.4.1.4467.100.500.100.10.2.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current Port's Signal Detect status
| ||||
| CflSfpPortLink | 1.3.6.1.4.1.4467.100.500.100.10.2.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current Port's Link status
| ||||
| CflSfpPortEnable | 1.3.6.1.4.1.4467.100.500.100.10.2.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current Port's Enable mode
| ||||
| TflSfpDeviceMonitoringTable | 1.3.6.1.4.1.4467.100.500.100.10.3 | NA | ||
table · not-accessible · current Table for SFP monitoring (digital diagnostics) data | ||||
| RflSfpDeviceMonitoringEntry | 1.3.6.1.4.1.4467.100.500.100.10.3.1 | NA | ||
row · not-accessible · current The entries of the table. | ||||
| CflSfpDeviceMonitoringRxPower | 1.3.6.1.4.1.4467.100.500.100.10.3.1.1 | INTEGER | RO | |
column · INTEGER · read-only · current Received average optical power in [0.01dBm]
| ||||
| CflSfpDeviceMonitoringTxPower | 1.3.6.1.4.1.4467.100.500.100.10.3.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current Transmitted average optical power in [0.01dBm]
| ||||
| CflSfpDeviceMonitoringTemperature | 1.3.6.1.4.1.4467.100.500.100.10.3.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current Device temperature in [0.1oC]
| ||||
| CflSfpDeviceMonitoringTxBias | 1.3.6.1.4.1.4467.100.500.100.10.3.1.4 | INTEGER | RO | |
column · INTEGER · read-only · current Transmitter bias current in [uA]
| ||||
| CflSfpDeviceMonitoringSupplyVoltage | 1.3.6.1.4.1.4467.100.500.100.10.3.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current Internal supply voltage in [100uV]
| ||||