FIBROLAN-DEVICE-MIB
FibrolanThe MIB module to describe a Fibrolan device's system level attributes. This module includes the relevant traps as well. This module is part of Fibrolan's group of generic MIB modules. Copyright (C) Fibrolan Ltd. (2009).
snmptranslate -m FIBROLAN-DEVICE-MIB -Tpsnmpwalk -v2c -c <community> -m FIBROLAN-DEVICE-MIB <host> 1.3.6.1.4.1.4467.1000.10Imports
| FIBROLAN-COMMON-MIB | FlFileServerType, FlFileXferDirection, FlTemperature, FlUtilization, fibrolanGeneric |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IflDevice | 1.3.6.1.4.1.4467.1000.10 | ||||||||||||||||||||
identity The MIB module to describe a Fibrolan device's system level attributes. This module includes the relevant traps as well. This module is part of Fibrolan's group of generic MIB modules. Copyright (C) Fibrolan Ltd. (2009). | |||||||||||||||||||||
| NflDeviceNotifications | 1.3.6.1.4.1.4467.1000.10.0 | ||||||||||||||||||||
| !psuStatusChange | 1.3.6.1.4.1.4467.1000.10.0.10 | ||||||||||||||||||||
notification · current PSU module state changed (fail or fan fail). Vars: PSU alarm status, PSU status last change | |||||||||||||||||||||
| !dyingGasp | 1.3.6.1.4.1.4467.1000.10.0.11 | ||||||||||||||||||||
notification · current Device is losing power. This is the only trap that will be generated when the device is experiencing total power loss. Cleared by a coldStart alarm. Vars: none. | |||||||||||||||||||||
| !temperatureStatusChange | 1.3.6.1.4.1.4467.1000.10.0.12 | ||||||||||||||||||||
notification · current Device's internal temperature status has changed. Vars: temperature alarm status, temperature last change | |||||||||||||||||||||
| !cpuStatusChange | 1.3.6.1.4.1.4467.1000.10.0.13 | ||||||||||||||||||||
notification · current CPU (or memory) status has changed. Vars: CPU alarm status, PCU status last change | |||||||||||||||||||||
| !portMacLimit | 1.3.6.1.4.1.4467.1000.10.0.19 | ||||||||||||||||||||
| !configChanged | 1.3.6.1.4.1.4467.1000.10.0.50 | ||||||||||||||||||||
notification · current Device configuration has changed. Indicates the startup config was updated (even if it wasn't changed), as a result of a copy running to startup operation. | |||||||||||||||||||||
| NflDeviceMIBObjects | 1.3.6.1.4.1.4467.1000.10.1 | ||||||||||||||||||||
| SflDeviceReboot | 1.3.6.1.4.1.4467.1000.10.1.10 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Trigger a system reboot. The following sequence must be performed in order for the operation to be triggered: - read the object's value - must be 'ready' - set the value to 'notReady' (acts as a sema4 lock) - set the value to 'reboot'
| |||||||||||||||||||||
| SflDeviceRestoreDefaults | 1.3.6.1.4.1.4467.1000.10.1.11 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Trigger a system restore defaults operation. The following sequence must be performed in order for the operation to be triggered: - read the object's value - must be 'ready' - set the value to 'notReady' (acts as a sema4 lock) - set the value to 'restoreDefaults'.
| |||||||||||||||||||||
| SflDeviceSaveConfig | 1.3.6.1.4.1.4467.1000.10.1.12 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Trigger save of the running config to NV memory (normally becomes the startup config). The following sequence must be performed in order for the operation to be triggered: - read the object's value - must be 'ready' - set the value to 'notReady' (acts as a sema4 lock) - set the value to 'saveConfig'.
| |||||||||||||||||||||
| SflDeviceTemperature | 1.3.6.1.4.1.4467.1000.10.1.13 | FlTemperature | RO | ||||||||||||||||||
scalar · FlTemperature · read-only · current The internal device temperature in degrees Centigrade. | |||||||||||||||||||||
| SflDeviceTemperatureAlarmsEnable | 1.3.6.1.4.1.4467.1000.10.1.14 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Determine whether temperature traps are generated. When disabled, the alarm status object should not be polled (will indicate no alarm).
| |||||||||||||||||||||
| SflDeviceTemperatureAlarmStatus | 1.3.6.1.4.1.4467.1000.10.1.15 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This variable indicates the alarm status of the device's temperature.
| |||||||||||||||||||||
| SflDeviceTemperatureStatusLastChange | 1.3.6.1.4.1.4467.1000.10.1.16 | TimeTicks | RO | ||||||||||||||||||
scalar · TimeTicks · read-only · current The value of MIB II's sysUpTime object at the time the device entered its current temperature status state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value. | |||||||||||||||||||||
| TflDevicePsuStatusTable | 1.3.6.1.4.1.4467.1000.10.1.100 | NA | |||||||||||||||||||
table · not-accessible · current Device Power Supply Unit (PSU) status table. | |||||||||||||||||||||
| RflDevicePsuStatusEntry | 1.3.6.1.4.1.4467.1000.10.1.100.1 | NA | |||||||||||||||||||
| CflDevicePsuIndex | 1.3.6.1.4.1.4467.1000.10.1.100.1.1 | Integer32 (1..3) | NA | ||||||||||||||||||
column · Integer32 (1..3) · not-accessible · current The index of the PSU. | |||||||||||||||||||||
| CflDevicePsuInstalled | 1.3.6.1.4.1.4467.1000.10.1.100.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Indicates whether PSU is installed or not (in slot)
| |||||||||||||||||||||
| CflDevicePsuStatus | 1.3.6.1.4.1.4467.1000.10.1.100.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current PSU operational status (supplying adequate power/voltage)
| |||||||||||||||||||||
| CflDevicePsuFanStatus | 1.3.6.1.4.1.4467.1000.10.1.100.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current PSU fan operational status (if applicable). singleFail indicates one of two (or more) fans have failed.
| |||||||||||||||||||||
| CflDevicePsuAlarmsEnable | 1.3.6.1.4.1.4467.1000.10.1.100.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Determine whether PSU traps are generated for this PSU slot. When disabled, the alarm status object should not be polled (will indicate no alarm).
| |||||||||||||||||||||
| CflDevicePsuAlarmStatus | 1.3.6.1.4.1.4467.1000.10.1.100.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This variable indicates the alarm status of the device's PSUs. fanDown indicates all fans of the power supply are down.
| |||||||||||||||||||||
| CflDevicePsuStatusLastChange | 1.3.6.1.4.1.4467.1000.10.1.100.1.7 | TimeTicks | RO | ||||||||||||||||||
column · TimeTicks · read-only · current The value of MIB II's sysUpTime object at the time the PSU entered its current state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value. | |||||||||||||||||||||
| TflDeviceUpdateTable | 1.3.6.1.4.1.4467.1000.10.1.110 | NA | |||||||||||||||||||
table · not-accessible · current Device (remote) update table. This table is used for uploading and downloading of maintenance related files (i.e. upgrades and configuration) from and to the system. In order to perform an update operation, the following objects should be set (assuming the operation is supported by the system): - operation type - remote file server type - remote file server address - operation direction (up/download) - file name After these have been set, the action may be triggered by the start object. Update status can be monitored via the status and error status objects. | |||||||||||||||||||||
| RflDeviceUpdateEntry | 1.3.6.1.4.1.4467.1000.10.1.110.1 | NA | |||||||||||||||||||
| CflDeviceUpdateTableIndex | 1.3.6.1.4.1.4467.1000.10.1.110.1.1 | Unsigned32 (0) | NA | ||||||||||||||||||
column · Unsigned32 (0) · not-accessible · current Table index. | |||||||||||||||||||||
| CflDeviceUpdateType | 1.3.6.1.4.1.4467.1000.10.1.110.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Update type (target).
| |||||||||||||||||||||
| CflDeviceUpdateFileServerType | 1.3.6.1.4.1.4467.1000.10.1.110.1.3 | FlFileServerType | RW | ||||||||||||||||||
column · FlFileServerType · read-write · current The type of remote file server (e.g. TFTP), from which the update file will be retrieved, or to which it will be saved. The type is effectively the file transfer protocol used. If the desired protocol is not present in the list, other(1) should be selected. | |||||||||||||||||||||
| CflDeviceUpdateFileServerAddress | 1.3.6.1.4.1.4467.1000.10.1.110.1.4 | IpAddress | RW | ||||||||||||||||||
column · IpAddress · read-write · current The IP address of the remote file server (e.g. TFTP), from which the update file will be retrieved, or to which it will be saved. Address must be a valid unicast IP address. | |||||||||||||||||||||
| CflDeviceUpdateFileXferDirection | 1.3.6.1.4.1.4467.1000.10.1.110.1.5 | FlFileXferDirection | RW | ||||||||||||||||||
column · FlFileXferDirection · read-write · current The direction in which the update file transfer will be performed: to or from the remote server. | |||||||||||||||||||||
| CflDeviceUpdateFileName | 1.3.6.1.4.1.4467.1000.10.1.110.1.6 | DisplayString (SIZE (0..255)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-write · current The name of the update file. Some systems may not support this object, in which case the name is set using the version name object. The file name may include a remote path. | |||||||||||||||||||||
| CflDeviceUpdateStart | 1.3.6.1.4.1.4467.1000.10.1.110.1.7 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Trigger the update process. Setting this object to start(2) will initiate the update operation. This can be done only when the object's value is ready(0). If notReady(1) is indicated, the operation should not be attempted and may be rejected by the device.
| |||||||||||||||||||||
| CflDeviceUpdateStatus | 1.3.6.1.4.1.4467.1000.10.1.110.1.8 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the update process. Some systems or update processes may support this object partially (i.e. not implement all states).
| |||||||||||||||||||||
| CflDeviceUpdateErrorStatus | 1.3.6.1.4.1.4467.1000.10.1.110.1.9 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of the update process. Some systems or update processes may support this object partially (i.e. not implement all errors).
| |||||||||||||||||||||
| CflDeviceUpdateErrorCode | 1.3.6.1.4.1.4467.1000.10.1.110.1.10 | Integer32 (0..10000) | RO | ||||||||||||||||||
column · Integer32 (0..10000) · read-only · current Indicates the error code of the last update operation. If no errors occured (operation completed successfully) this object should be 0. The meaning of the error code depends on the update type. For example: in a configuration file load (from the server) this value can be the line number within the config file which contained the error. Refer to relevant system documentation for further details. | |||||||||||||||||||||
| CflDeviceUpdateUrl | 1.3.6.1.4.1.4467.1000.10.1.110.1.11 | DisplayString (SIZE (0..255)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-write · current The URL string of the update file. In most systems, when this field is used, other fields (e.g. IP address) will not be used. | |||||||||||||||||||||
| TflDeviceCpuStatusTable | 1.3.6.1.4.1.4467.1000.10.1.120 | NA | |||||||||||||||||||
table · not-accessible · current CPU Status table. Provides information regarding system's CPU(s) and memory resources. This table is extending the relevant entries in the Entity MIB (physical, for CPUs). This table has some common objects with the HOST-RESOURCES-MIB (RFC2790). | |||||||||||||||||||||
| RflDeviceCpuStatusEntry | 1.3.6.1.4.1.4467.1000.10.1.120.1 | NA | |||||||||||||||||||
| CflDeviceCpuIndex | 1.3.6.1.4.1.4467.1000.10.1.120.1.1 | Integer32 (0..2) | NA | 0 | |||||||||||||||||
column · Integer32 (0..2) · not-accessible · current Index of the CPU table (will be 0 only in most systems). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflDeviceCpuUtilization | 1.3.6.1.4.1.4467.1000.10.1.120.1.2 | FlUtilization | RO | 96 | |||||||||||||||||
column · FlUtilization · read-only · current Utilization (load) of the CPU in percents of maximum capacity. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflDeviceMemoryUtilization | 1.3.6.1.4.1.4467.1000.10.1.120.1.3 | FlUtilization | RO | -1 | |||||||||||||||||
column · FlUtilization · read-only · current Utilization (usage) of the memory in percents of physical memory size. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflDeviceNvMemoryUtilization | 1.3.6.1.4.1.4467.1000.10.1.120.1.4 | FlUtilization | RO | 0 | |||||||||||||||||
column · FlUtilization · read-only · current Utilization (usage) of the NV memory in percents of physical NV memory size. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflDeviceCpuAlarmsEnable | 1.3.6.1.4.1.4467.1000.10.1.120.1.5 | INTEGER | RW | disable(2) | |||||||||||||||||
column · INTEGER · read-write · current Determine whether CPU traps are generated. When disabled, the alarm status object should not be polled (will indicate no alarm).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflDeviceCpuAlarmStatus | 1.3.6.1.4.1.4467.1000.10.1.120.1.6 | Integer32 | RO | 1 | |||||||||||||||||
column · Integer32 · read-only · current This variable indicates the alarm status of the device's CPU(s) and memory. This object is a bitmap represented as a sum; therefore, it can represent multiple alarms. The noAlarm bit must be set if and only if no other flag is set. The various alarm bit positions (right to left) are as follows: 1 noAlarm No active alarms 2 cpuUtilizationHigh CPU util exceeds threshold 3 memoryUtilizationHigh Memory util exceeds threshold Example values from LibreNMS test devices
| |||||||||||||||||||||
| CflDeviceCpuStatusLastChange | 1.3.6.1.4.1.4467.1000.10.1.120.1.7 | TimeTicks | RO | 0 (0d 0h 0m 0s) | |||||||||||||||||
column · TimeTicks · read-only · current The value of MIB II's sysUpTime object at the time the CPU entered its current state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TflDeviceAlarmThresholdTable | 1.3.6.1.4.1.4467.1000.10.1.500 | NA | |||||||||||||||||||
table · not-accessible · current Alarm thresholds table. This table provides configuration facilities for threshold crossing alarms (TCA) defined in this MIB module. | |||||||||||||||||||||
| RflDeviceAlarmThresholdEntry | 1.3.6.1.4.1.4467.1000.10.1.500.1 | NA | |||||||||||||||||||
row · not-accessible · current The entries of the alarm threshold table. | |||||||||||||||||||||
| CflDeviceAlarmThresholdTableIndex | 1.3.6.1.4.1.4467.1000.10.1.500.1.1 | Unsigned32 (0..31) | NA | ||||||||||||||||||
column · Unsigned32 (0..31) · not-accessible · current Table index. | |||||||||||||||||||||
| CflDeviceAlarmThresholdType | 1.3.6.1.4.1.4467.1000.10.1.500.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The type of the threshold (enumerated). This object is expected to be extended with new types in future revisions.
| |||||||||||||||||||||
| CflDeviceAlarmThresholdValue | 1.3.6.1.4.1.4467.1000.10.1.500.1.3 | Integer32 (-100..100) | RW | ||||||||||||||||||
column · Integer32 (-100..100) · read-write · current The threshold value beyond which the alarm is active. Note: the type of the threshold determines whether this value is the upper bound for the alarm activation (e.g. temperatureHigh) or the lower bound (e.g. temperatureLow). | |||||||||||||||||||||
| CflDeviceAlarmThresholdClearValue | 1.3.6.1.4.1.4467.1000.10.1.500.1.4 | Integer32 (-100..100) | RW | ||||||||||||||||||
column · Integer32 (-100..100) · read-write · current The threshold value below which the alarm is cleared. Note: the type of the threshold determines whether this value is the upper bound for the alarm activation (e.g. temperatureLow) or the lower bound (e.g. temperatureHigh). | |||||||||||||||||||||
Traps / Notifications
- configChanged
1.3.6.1.4.1.4467.1000.10.0.50 - cpuStatusChange
1.3.6.1.4.1.4467.1000.10.0.13 - dyingGasp
1.3.6.1.4.1.4467.1000.10.0.11 - portMacLimit
1.3.6.1.4.1.4467.1000.10.0.19 - psuStatusChange
1.3.6.1.4.1.4467.1000.10.0.10 - temperatureStatusChange
1.3.6.1.4.1.4467.1000.10.0.12