XMUX4-PLUS
Fibernet InternationalThe Structure of Management Information for the Fibernet enterprise
snmptranslate -m XMUX4-PLUS -Tpsnmpwalk -v2c -c <community> -m XMUX4-PLUS <host> 1.3.6.1.4.1.29003Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ifibernet | 1.3.6.1.4.1.29003 | ||||||||||||||||||||
identity The Structure of Management Information for the Fibernet enterprise | |||||||||||||||||||||
| Nfbntransport | 1.3.6.1.4.1.29003.2 | ||||||||||||||||||||
| NfbnXMux4Plus | 1.3.6.1.4.1.29003.2.44 | ||||||||||||||||||||
| Nmux4Plus | 1.3.6.1.4.1.29003.2.44.1 | ||||||||||||||||||||
| Ndmux4 | 1.3.6.1.4.1.29003.2.44.1.1 | ||||||||||||||||||||
| SidentityMux4 | 1.3.6.1.4.1.29003.2.44.1.1.1 | DisplayString (SIZE (0..255)) | RO | NS:22182 CP:53/0 VH:1 VS:111 VF:0 | |||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Identification main XMUX : Serial number, product code, configuration extended , hardware and software version // Identificacion del XMUX principal : Numero de serie , codigo de producto, extension de configuracion,version hardware y version software Example values from LibreNMS test devices
| |||||||||||||||||||||
| Snumbermux | 1.3.6.1.4.1.29003.2.44.1.1.2 | Integer32 | RO | 1 | |||||||||||||||||
scalar · Integer32 · read-only · current Number of xmuxs // Número de xmux gestionados Example values from LibreNMS test devices
| |||||||||||||||||||||
| SnumberChannel | 1.3.6.1.4.1.29003.2.44.1.1.3 | Integer32 | RO | 4 | |||||||||||||||||
scalar · Integer32 · read-only · current Number of channels // Número de canales totales gestionados Example values from LibreNMS test devices
| |||||||||||||||||||||
| SstrTrapsMux4 | 1.3.6.1.4.1.29003.2.44.1.1.4 | DisplayString | RO | <Xmux+ 1 channel 4> | |||||||||||||||||
scalar · DisplayString · read-only · current Traps information attached // Información anexa traps Example values from LibreNMS test devices
| |||||||||||||||||||||
| StrapmuxIndex | 1.3.6.1.4.1.29003.2.44.1.1.5 | Integer32 | RO | 1 | |||||||||||||||||
scalar · Integer32 · read-only · current XMux which cause the trap // XMux que genera el Trap Example values from LibreNMS test devices
| |||||||||||||||||||||
| StrapchannelIndex | 1.3.6.1.4.1.29003.2.44.1.1.6 | Integer32 | RO | 4 | |||||||||||||||||
scalar · Integer32 · read-only · current Channel which cause the trap // Canal que genera el Trap Example values from LibreNMS test devices
| |||||||||||||||||||||
| StrapValue | 1.3.6.1.4.1.29003.2.44.1.1.7 | INTEGER | RO | on(1) | |||||||||||||||||
scalar · INTEGER · read-only · current (On) (Off)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SstrDescription | 1.3.6.1.4.1.29003.2.44.1.1.8 | DisplayString | RO | | |||||||||||||||||
scalar · DisplayString · read-only · current Administrative description // Descripción administrativa Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmuxTable | 1.3.6.1.4.1.29003.2.44.1.1.9 | NA | |||||||||||||||||||
table · not-accessible · current XMUX information general array // Tabla con la informacion general de los XMUX | |||||||||||||||||||||
| RmuxEntry | 1.3.6.1.4.1.29003.2.44.1.1.9.1 | NA | |||||||||||||||||||
| CmuxTableIndex | 1.3.6.1.4.1.29003.2.44.1.1.9.1.1 | Integer32 | RO | 1 | |||||||||||||||||
column · Integer32 · read-only · current XMUX order // Número de xmux Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxIdentity | 1.3.6.1.4.1.29003.2.44.1.1.9.1.2 | DisplayString | RO | NS:22182 CP:53/0 VH:1 VS:111 VF:0 | |||||||||||||||||
column · DisplayString · read-only · current Identification main XMUX : Serial number, product code, configuration extended , hardware and software version // Identificacion del XMUX principal : Numero de serie , codigo de producto, extension de configuracion,version hardware y version software Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxAlarmStatus | 1.3.6.1.4.1.29003.2.44.1.1.9.1.3 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current Channel alarm // Indica si esta encendido (On) o no (Off) el led ALARMA de un canal
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxFanTemp | 1.3.6.1.4.1.29003.2.44.1.1.9.1.4 | DisplayString | RO | 26.00 | |||||||||||||||||
column · DisplayString · read-only · current Channel's fan temperature // Indica la temperatura del canal Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxInteriorTemp | 1.3.6.1.4.1.29003.2.44.1.1.9.1.5 | DisplayString | RO | 31.08 | |||||||||||||||||
column · DisplayString · read-only · current Channel's interior temperature // Indica la temperatura del canal Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxVolt3v3 | 1.3.6.1.4.1.29003.2.44.1.1.9.1.6 | DisplayString | RO | 3.00 | |||||||||||||||||
column · DisplayString · read-only · current Channel's 3,3 voltage // Indica el voltaje del 3,3 del canal Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxVolt2v5 | 1.3.6.1.4.1.29003.2.44.1.1.9.1.7 | DisplayString | RO | 2.32 | |||||||||||||||||
column · DisplayString · read-only · current Channel's 2,5 voltage // Indica el voltaje del 2,5 del canal Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxVolt1v2 | 1.3.6.1.4.1.29003.2.44.1.1.9.1.8 | DisplayString | RO | 1.13 | |||||||||||||||||
column · DisplayString · read-only · current Channel's 1,2 voltage // Indica el voltaje del 1,2 del canal Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxLeftPower | 1.3.6.1.4.1.29003.2.44.1.1.9.1.9 | INTEGER | RO | powerOn(1) | |||||||||||||||||
column · INTEGER · read-only · current Power supply status on the left // Estado de la alimentación interna izquierda
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxRightPower | 1.3.6.1.4.1.29003.2.44.1.1.9.1.10 | INTEGER | RO | powerOff(0) | |||||||||||||||||
column · INTEGER · read-only · current Power supply status on the right // Estado de la alimentación externa derecha
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxLeftPowerIdenti | 1.3.6.1.4.1.29003.2.44.1.1.9.1.11 | DisplayString | RO | 220V | |||||||||||||||||
column · DisplayString · read-only · current Power supply identification on the left // tipo de la alimentación interna izquierda Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxRightPowerIdenti | 1.3.6.1.4.1.29003.2.44.1.1.9.1.12 | DisplayString | RO | 220V | |||||||||||||||||
column · DisplayString · read-only · current Power supply identification on the right // tipo de la alimentación interna derecha Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxOpticalSN | 1.3.6.1.4.1.29003.2.44.1.1.9.1.13 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Optical serial number // Numero de serie de la optica Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmuxOpticalPN | 1.3.6.1.4.1.29003.2.44.1.1.9.1.14 | DisplayString | RO | | |||||||||||||||||
column · DisplayString · read-only · current Optical part number // Numero de serie de la optica Example values from LibreNMS test devices
| |||||||||||||||||||||
| TchannelTable | 1.3.6.1.4.1.29003.2.44.1.2 | NA | |||||||||||||||||||
table · not-accessible · current Channels information array // Tabla con la informacion de los canales | |||||||||||||||||||||
| RchannelEntry | 1.3.6.1.4.1.29003.2.44.1.2.1 | NA | |||||||||||||||||||
row · not-accessible · current Channel information // Informacion de un solo canal | |||||||||||||||||||||
| CchannelmuxIndex | 1.3.6.1.4.1.29003.2.44.1.2.1.1 | Integer32 | RO | 1 | |||||||||||||||||
column · Integer32 · read-only · current XMUX number // Número de orden XMUX Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelchannelIndex | 1.3.6.1.4.1.29003.2.44.1.2.1.2 | Integer32 | RO | 1 | |||||||||||||||||
column · Integer32 · read-only · current Channel order in XMUX // Número de canal dentro del XMUX Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelPresent | 1.3.6.1.4.1.29003.2.44.1.2.1.3 | INTEGER | RO | present(1) | |||||||||||||||||
column · INTEGER · read-only · current Channel is (Present) or (Missing) // Indica si el canal esta (Presente) o (Ausente)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalTx | 1.3.6.1.4.1.29003.2.44.1.2.1.4 | INTEGER | RO | on(1) | |||||||||||||||||
column · INTEGER · read-only · current Local transmision (On) or (Off) // Indica si el canal tiene transmisión local (On) o no (Off)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalRx | 1.3.6.1.4.1.29003.2.44.1.2.1.5 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current Local reception (On) or (Off) // Indica si el canal tiene recepcion local (On) o no (Off)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteTx | 1.3.6.1.4.1.29003.2.44.1.2.1.6 | INTEGER | RO | on(1) | |||||||||||||||||
column · INTEGER · read-only · current Remote transmision (On) or (Off) //Indica si el canal tiene transmisión remota (On) o no (Off)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteRx | 1.3.6.1.4.1.29003.2.44.1.2.1.7 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current Remote reception (On) or (Off) //Indica si el canal tiene recepcion remota (On) o no (Off)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalSfpPresent | 1.3.6.1.4.1.29003.2.44.1.2.1.8 | INTEGER | RO | present(1) | |||||||||||||||||
column · INTEGER · read-only · current Local SFP is (Present) or (Missing) // Indica si el SFP local esta (Presente) o (Ausente)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteXfpPresent | 1.3.6.1.4.1.29003.2.44.1.2.1.9 | INTEGER | RO | present(1) | |||||||||||||||||
column · INTEGER · read-only · current Remote SFP is (Present) or (Missing) // Indica si el SFP remoto esta (Presente) o (Ausente)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelBitRate | 1.3.6.1.4.1.29003.2.44.1.2.1.10 | DisplayString | RO | 10310000.00 | |||||||||||||||||
column · DisplayString · read-only · current Channel bitRate // Velocidad del Canal Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalByPass | 1.3.6.1.4.1.29003.2.44.1.2.1.11 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current Off clock to local loop // Off clock hacia bucle local
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteByPass | 1.3.6.1.4.1.29003.2.44.1.2.1.12 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current Off clock to remote loop // Off clock hacia bucle remoto
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelSDHCompatibility | 1.3.6.1.4.1.29003.2.44.1.2.1.13 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current SDH compatibility active // Compatibilidad SDH activa
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelOfc | 1.3.6.1.4.1.29003.2.44.1.2.1.14 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current OFC active // Pulsos OFC activos
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelSir | 1.3.6.1.4.1.29003.2.44.1.2.1.15 | INTEGER | RO | off(0) | |||||||||||||||||
column · INTEGER · read-only · current SIR // active SIR activo
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelMTwin | 1.3.6.1.4.1.29003.2.44.1.2.1.16 | INTEGER | RO | no(0) | |||||||||||||||||
column · INTEGER · read-only · current Mode TWIN active // En modo TWIN
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelSecondary | 1.3.6.1.4.1.29003.2.44.1.2.1.17 | INTEGER | RO | no(0) | |||||||||||||||||
column · INTEGER · read-only · current Secundaria de la pareja TWIN
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelActive | 1.3.6.1.4.1.29003.2.44.1.2.1.18 | INTEGER | RO | active(1) | |||||||||||||||||
column · INTEGER · read-only · current Channel status active or not active // Estado del canal. Activo ó Inactivo
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelBackup | 1.3.6.1.4.1.29003.2.44.1.2.1.19 | INTEGER | RO | no(0) | |||||||||||||||||
column · INTEGER · read-only · current Channel in backup // Canal en Backup.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLoop | 1.3.6.1.4.1.29003.2.44.1.2.1.20 | INTEGER | RO | no(0) | |||||||||||||||||
column · INTEGER · read-only · current Channel in Loop // Canal en bucle.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelBer | 1.3.6.1.4.1.29003.2.44.1.2.1.21 | INTEGER | RO | no(0) | |||||||||||||||||
column · INTEGER · read-only · current Channel in BER // Canal pasando BER
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalSfpType | 1.3.6.1.4.1.29003.2.44.1.2.1.22 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Kind of transceiver // Tipo de transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalSfpConector | 1.3.6.1.4.1.29003.2.44.1.2.1.23 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Kind of the conector // Tipo de conector Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalSfpCompatibility | 1.3.6.1.4.1.29003.2.44.1.2.1.24 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Compatibility transceiver // Compatibilidad del transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalSfpBitRate | 1.3.6.1.4.1.29003.2.44.1.2.1.25 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Transceiver BitRate // Velocidad del transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelLocalSfpWaveLength | 1.3.6.1.4.1.29003.2.44.1.2.1.26 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Transceiver WaveLength // Lambda del transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteXfpType | 1.3.6.1.4.1.29003.2.44.1.2.1.27 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Kind of transceiver // Tipo de transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteXfpConector | 1.3.6.1.4.1.29003.2.44.1.2.1.28 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Kind of the conector // Tipo de conector Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteXfpCompatibility | 1.3.6.1.4.1.29003.2.44.1.2.1.29 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Compatibility transceiver // Compatibilidad del transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteXfpBitRate | 1.3.6.1.4.1.29003.2.44.1.2.1.30 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Transceiver BitRate // Velocidad del transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelRemoteXfpWaveLength | 1.3.6.1.4.1.29003.2.44.1.2.1.31 | DisplayString | RO | No available / No disponible | |||||||||||||||||
column · DisplayString · read-only · current Transceiver WaveLength // Lambda del transceiver Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelDescription | 1.3.6.1.4.1.29003.2.44.1.2.1.32 | DisplayString | RO | | |||||||||||||||||
column · DisplayString · read-only · current Channel description // Descripcion del canal Example values from LibreNMS test devices
| |||||||||||||||||||||
| CchannelManagement | 1.3.6.1.4.1.29003.2.44.1.2.1.33 | INTEGER | RO | yes(1) | |||||||||||||||||
column · INTEGER · read-only · current Channel in/out management // Canal en/fuera de gestión
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nmux4PlusTraps | 1.3.6.1.4.1.29003.2.44.1.8 | ||||||||||||||||||||
| !channelLocalRxChange | 1.3.6.1.4.1.29003.2.44.1.8.1 | ||||||||||||||||||||
notification · current It was caused by a change in local reception // Se genera al producirse un cambio en la recepcion local de un canal | |||||||||||||||||||||
| !channelRemoteRxChange | 1.3.6.1.4.1.29003.2.44.1.8.2 | ||||||||||||||||||||
notification · current It was caused by a change in remote reception // Se genera al producirse un cambio en la recepcion remota de un canal | |||||||||||||||||||||
| !alarmaStatusChange | 1.3.6.1.4.1.29003.2.44.1.8.3 | ||||||||||||||||||||
notification · current It was caused by a change in ALARMA led // Se genera al producirse un cambio en el led ALARMA de un canal | |||||||||||||||||||||
| !channelActivoChange | 1.3.6.1.4.1.29003.2.44.1.8.4 | ||||||||||||||||||||
notification · current It was caused by a change in active status // Se genera al producirse un cambio en el estado Activo de un canal | |||||||||||||||||||||
| !powerLeftChange | 1.3.6.1.4.1.29003.2.44.1.8.5 | ||||||||||||||||||||
notification · current It was caused by a change in power supply on the left // Se genera al producirse un cambio en la fuente izquierda del equipo | |||||||||||||||||||||
| !powerRightChange | 1.3.6.1.4.1.29003.2.44.1.8.6 | ||||||||||||||||||||
notification · current It was caused by a change in power supply on the right // Se genera al producirse un cambio en la fuente derecha del equipo | |||||||||||||||||||||
| !configChange | 1.3.6.1.4.1.29003.2.44.1.8.7 | ||||||||||||||||||||
notification · current It was caused by a change device's config // Se genera al producirse un cambio en la configuración del equipo | |||||||||||||||||||||
Traps / Notifications
- alarmaStatusChange
1.3.6.1.4.1.29003.2.44.1.8.3 - channelActivoChange
1.3.6.1.4.1.29003.2.44.1.8.4 - channelLocalRxChange
1.3.6.1.4.1.29003.2.44.1.8.1 - channelRemoteRxChange
1.3.6.1.4.1.29003.2.44.1.8.2 - configChange
1.3.6.1.4.1.29003.2.44.1.8.7 - powerLeftChange
1.3.6.1.4.1.29003.2.44.1.8.5 - powerRightChange
1.3.6.1.4.1.29003.2.44.1.8.6