WRI-TEMPERATURE-MIB
Wuhan Research Institute of Posts and TelecommunicationsThe MIB module to describe the monitor for temperature.
snmptranslate -m WRI-TEMPERATURE-MIB -Tpsnmpwalk -v2c -c <community> -m WRI-TEMPERATURE-MIB <host> 1.3.6.1.4.1.3807.1.8012.1.6Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Counter32, Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| WRI-SMI | wri, wriProducts |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nmspp | 1.3.6.1.4.1.3807.1.8012 | ||||||||||||
| NmsppChassis | 1.3.6.1.4.1.3807.1.8012.1 | ||||||||||||
| ImsppTemperature | 1.3.6.1.4.1.3807.1.8012.1.6 | ||||||||||||
identity The MIB module to describe the monitor for temperature. | |||||||||||||
| NtemperatureGeneral | 1.3.6.1.4.1.3807.1.8012.1.6.1 | ||||||||||||
| StemperatureTrapEnable | 1.3.6.1.4.1.3807.1.8012.1.6.1.1 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current Enable temperature trap or not.
| |||||||||||||
| StemperatureMonitorEnable | 1.3.6.1.4.1.3807.1.8012.1.6.1.2 | INTEGER | RW | ||||||||||
scalar · INTEGER · read-write · current Enable temperature monitor or not.
| |||||||||||||
| StemperatureNumber | 1.3.6.1.4.1.3807.1.8012.1.6.1.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current Temperature numbers | |||||||||||||
| TtemperatureTable | 1.3.6.1.4.1.3807.1.8012.1.6.2 | NA | |||||||||||
table · not-accessible · current Temperature information table. | |||||||||||||
| RtemperatureEntry | 1.3.6.1.4.1.3807.1.8012.1.6.2.1 | NA | |||||||||||
| CtemperatureIndex | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.1 | Unsigned32 | RO | 2148733184 | |||||||||
column · Unsigned32 · read-only · current Unique index for the temperature. Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureDescr | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.2 | DisplayString (SIZE (0..64)) | RW | Sensor 1 Tempera
74 75 72 65 00 00 00 00 00 00 … | |||||||||
column · DisplayString (SIZE (0..64)) · read-write · current temperature description.slot-1-temp1,slot-1-tem2,eg. Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureLThreshold | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.3 | INTEGER | RW | -10 | |||||||||
column · INTEGER · read-write · current temperature low threshold Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureHThreshold | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.4 | INTEGER | RW | 80 | |||||||||
column · INTEGER · read-write · current temperature high threshold Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureValue | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.5 | INTEGER | RO | 36 | |||||||||
column · INTEGER · read-only · current temperature value. Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureState | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.6 | INTEGER | RO | normal(0) | |||||||||
column · INTEGER · read-only · current temperature state.
Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureTrapEna | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.7 | INTEGER | RW | enable(1) | |||||||||
column · INTEGER · read-write · current Enable temperature trap or not.
Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureAllSetting | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.8 | OCTET STRING | RW | Sensor 1 Tempera
74 75 72 65 00 00 00 00 00 00 … | |||||||||
column · OCTET STRING · read-write · current All oid operation of this table. Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureIndexDescr | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.9 | OCTET STRING | RO | Temper-1/0/1 | |||||||||
column · OCTET STRING · read-only · current Temperature index descrption. Example values from LibreNMS test devices
| |||||||||||||
| CtemperatureRebootHThreshold | 1.3.6.1.4.1.3807.1.8012.1.6.2.1.10 | INTEGER | RW | 0 | |||||||||
column · INTEGER · read-write · current temperature high threshold for reboot Example values from LibreNMS test devices
| |||||||||||||
| NtemperatureTrap | 1.3.6.1.4.1.3807.1.8012.1.6.3 | ||||||||||||
| !temperatureOk | 1.3.6.1.4.1.3807.1.8012.1.6.3.1 | ||||||||||||
| !temperatureFault | 1.3.6.1.4.1.3807.1.8012.1.6.3.2 | ||||||||||||
notification · current mspp temperature fault trap. | |||||||||||||
Textual conventions
DisplayStringOCTET STRING8 bit octet.
Traps / Notifications
- temperatureFault
1.3.6.1.4.1.3807.1.8012.1.6.3.2 - temperatureOk
1.3.6.1.4.1.3807.1.8012.1.6.3.1