The MIB module to describe the monitor for power.
snmptranslate -m WRI-POWER-MIB -Tpsnmpwalk -v2c -c <community> -m WRI-POWER-MIB <host> 1.3.6.1.4.1.3807.1.8012.1.2Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Counter32, Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
| WRI-SMI | wri, wriProducts |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nmspp | 1.3.6.1.4.1.3807.1.8012 | ||||||||||||||||
| NmsppChassis | 1.3.6.1.4.1.3807.1.8012.1 | ||||||||||||||||
| ImsppPower | 1.3.6.1.4.1.3807.1.8012.1.2 | ||||||||||||||||
identity The MIB module to describe the monitor for power. | |||||||||||||||||
| TpowerTable | 1.3.6.1.4.1.3807.1.8012.1.2.1 | NA | |||||||||||||||
table · not-accessible · current Power information table. | |||||||||||||||||
| RpowerEntry | 1.3.6.1.4.1.3807.1.8012.1.2.1.1 | NA | |||||||||||||||
| CpowerIndex | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.1 | Unsigned32 | RO | 1611796736 | |||||||||||||
column · Unsigned32 · read-only · current power index. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerType | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.2 | INTEGER | RO | acdc(1) | |||||||||||||
column · INTEGER · read-only · current power type, 0:DC/DC,1:AC/DC.
Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerState | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.3 | INTEGER | RO | voltagelack(1) | |||||||||||||
column · INTEGER · read-only · current power state, 0:normal,1:voltage lack,2:voltage overload.
Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerValue | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.4 | INTEGER | RO | 0 | |||||||||||||
column · INTEGER · read-only · current power value. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerRole | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.5 | INTEGER | RW | 0 | |||||||||||||
column · INTEGER · read-write · current power role. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerDescr | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.6 | OCTET STRING | RW | 50:57:52:2d:4c:00:00:00 | |||||||||||||
column · OCTET STRING · read-write · current power description. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerSerial | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.7 | OCTET STRING | RO | N/A | |||||||||||||
column · OCTET STRING · read-only · current power serial. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerTemperature | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.8 | INTEGER | RO | 0 | |||||||||||||
column · INTEGER · read-only · current power temperature. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerFuseStatus | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.9 | INTEGER | RO | 1 | |||||||||||||
column · INTEGER · read-only · current power fuse status. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerStateBits | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.10 | INTEGER | RO | voltagelack(1) | |||||||||||||
column · INTEGER · read-only · current bits description for power states, redundance of powerState.
Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerTrapEna | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.11 | INTEGER | RW | enable(1) | |||||||||||||
column · INTEGER · read-write · current Enable power trap or not.
Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerAllSetting | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.12 | OCTET STRING | RW | 4e:2f:41:00:00:00:00:00:00:00:00:00:00:00:00:00… | |||||||||||||
column · OCTET STRING · read-write · current All oid operation of this table. Example values from LibreNMS test devices
| |||||||||||||||||
| CpowerIndexDescr | 1.3.6.1.4.1.3807.1.8012.1.2.1.1.13 | OCTET STRING | RO | Power-1/1 | |||||||||||||
column · OCTET STRING · read-only · current Power index descrption. Example values from LibreNMS test devices
| |||||||||||||||||
| NpowerTrap | 1.3.6.1.4.1.3807.1.8012.1.2.2 | ||||||||||||||||
| !powerUp | 1.3.6.1.4.1.3807.1.8012.1.2.2.1 | ||||||||||||||||
| !powerDown | 1.3.6.1.4.1.3807.1.8012.1.2.2.2 | ||||||||||||||||
| !powerFault | 1.3.6.1.4.1.3807.1.8012.1.2.2.3 | ||||||||||||||||
| !powerOk | 1.3.6.1.4.1.3807.1.8012.1.2.2.4 | ||||||||||||||||
| NpowerGeneral | 1.3.6.1.4.1.3807.1.8012.1.2.3 | ||||||||||||||||
| SpowerBits | 1.3.6.1.4.1.3807.1.8012.1.2.3.1 | Counter32 | RO | ||||||||||||||
scalar · Counter32 · read-only · current Bitsmap for all power being on. | |||||||||||||||||
| SpowerNum | 1.3.6.1.4.1.3807.1.8012.1.2.3.2 | INTEGER | RO | ||||||||||||||
scalar · INTEGER · read-only · current power numbers. | |||||||||||||||||
| SpowerTrapEnable | 1.3.6.1.4.1.3807.1.8012.1.2.3.3 | INTEGER | RW | ||||||||||||||
scalar · INTEGER · read-write · current Enable fan trap or not.
| |||||||||||||||||
| SpowerMonitorEnable | 1.3.6.1.4.1.3807.1.8012.1.2.3.4 | INTEGER | RW | ||||||||||||||
scalar · INTEGER · read-write · current Enable power monitor or not.
| |||||||||||||||||
Traps / Notifications
- powerDown
1.3.6.1.4.1.3807.1.8012.1.2.2.2 - powerFault
1.3.6.1.4.1.3807.1.8012.1.2.2.3 - powerOk
1.3.6.1.4.1.3807.1.8012.1.2.2.4 - powerUp
1.3.6.1.4.1.3807.1.8012.1.2.2.1