EXTREME-POE-MIB
Extreme NetworksExtreme Power over Ethernet MIB objects
snmptranslate -m EXTREME-POE-MIB -Tpsnmpwalk -v2c -c <community> -m EXTREME-POE-MIB <host> 1.3.6.1.4.1.1916.1.27Imports
| EXTREME-BASE-MIB | extremeAgent, extremeV2Traps |
|---|---|
| POWER-ETHERNET-MIB | pethMainPseGroupIndex, pethPsePortGroupIndex, pethPsePortIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IextremePoE | 1.3.6.1.4.1.1916.1.27 | |||
identity Extreme Power over Ethernet MIB objects | ||||
| NextremePethMain | 1.3.6.1.4.1.1916.1.27.1 | |||
| TextremePethPseSlotTable | 1.3.6.1.4.1.1916.1.27.1.2 | NA | ||
table · not-accessible · current A table of objects that provides power management capabilities per slot. | ||||
| RextremePethPseSlotEntry | 1.3.6.1.4.1.1916.1.27.1.2.1 | NA | ||
row · not-accessible · current A set of objects that display and control the power characteristics of a slot. | ||||
| CextremePethSlotNumber | 1.3.6.1.4.1.1916.1.27.1.2.1.1 | Integer32 (1..162) | NA | |
column · Integer32 (1..162) · not-accessible · current Slot number. This is the same as the Group Index | ||||
| CextremePethSlotPowerLimit | 1.3.6.1.4.1.1916.1.27.1.2.1.2 | Integer32 | RW | |
column · Integer32 · read-write · current The configured maximum amount of inline power available to slot. The operational power available to the slot is based upon other operational and configuration parameters, such as the power-supply mode and status. This number is provided by the object extremePethSlotMaxAvailPower. extremePethSlotPowerLimit may be greater than extremePethSlotMaxAvailPower, however, cannot exceed the maximum slot capacity, provided by extremePethSlotMaxCapacity
| ||||
| CextremePethSlotConsumptionPower | 1.3.6.1.4.1.1916.1.27.1.2.1.3 | Gauge32 | RO | |
column · Gauge32 · read-only · current The amount of power allocated to PoE devices on the slot expressed in Watts. The amount of power allocated to a PoE device is based upon the PoE device class and/or the port's extremePethPortViolationPrecedence setting. For example, in the default configuration of extremePethPortViolationPrecedence set to maxAdvertisedOperator(3), and the extremePethPortOperatorLimit set to 15400, a PoE device is allocated 15.4 watts.
| ||||
| CextremePethSlotClearConnectHistory | 1.3.6.1.4.1.1916.1.27.1.2.1.4 | INTEGER | RW | |
column · INTEGER · read-write · current Clears the port connection history of the specified slot. Reading the value always reurns clear(2).
| ||||
| CextremePethSlotReservedConsumptionPower | 1.3.6.1.4.1.1916.1.27.1.2.1.5 | Gauge32 | RO | |
column · Gauge32 · read-only · current The amount of reserved power consumed on the slot expressed in Milliwatts.
| ||||
| CextremePethSlotCommonConsumptionPower | 1.3.6.1.4.1.1916.1.27.1.2.1.6 | Gauge32 | RO | |
column · Gauge32 · read-only · current The amount of common power allocated on the slot expressed in Milliwatts. This value is computed by the formula: extremePethSlotConsumptionPower - extremePethSlotReservedConsumptionPower.
| ||||
| CextremePethSlotAdminEnable | 1.3.6.1.4.1.1916.1.27.1.2.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current Controls whether inline power is provided by the slot.
| ||||
| CextremePethSlotPoeStatus | 1.3.6.1.4.1.1916.1.27.1.2.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current Describes the status of the PoE system on the slot.
initializing - PoE controller is under initialization,
operational - PoE controller is operational and is ready or
providing power,
downloadFail - PoE controller required update and the update
failed, PoE reset is required to re-update,
calibrationRequired - PoE contoller is operational, however
calibration is required to provide power,
invalidFirmware - PoE controller contains invalid firmware,
mismatchVersion - PoE controller update completed, however
version mismatches expected, reboot,
updating - PoE controller is being updated,
invalidDevice - PoE controller detected an invalid/bad PoE
device.
notOperational - PoE controller is not yet operational
other - PoE controller is in undefined stats.
| ||||
| CextremePethSlotPoeResetSystem | 1.3.6.1.4.1.1916.1.27.1.2.1.9 | INTEGER | RW | |
column · INTEGER · read-write · current Resets the PoE system on the slot. Reading returns clear(2)
| ||||
| CextremePethSlotMaxAvailPower | 1.3.6.1.4.1.1916.1.27.1.2.1.10 | Gauge32 | RO | |
column · Gauge32 · read-only · current The maximum power available to the slot expressed in Watts.
The value depends on various configuration parameters and
power-supply modes and status.
| ||||
| CextremePethSlotMaxCapacity | 1.3.6.1.4.1.1916.1.27.1.2.1.11 | Gauge32 | RO | |
column · Gauge32 · read-only · current The maximum capacity of the slot expressed in Watts. This provides the hardware limitation of the slot. Actual amount of power is dependant on system status. The object extremePethSlotPowerLimit must not be greater than this amount.
| ||||
| CextremePethSlotBackupPSU | 1.3.6.1.4.1.1916.1.27.1.2.1.12 | INTEGER | RW | |
column · INTEGER · read-write · current Controls the backup power supply for inline power for the slot. A system which does not allow the backup PSU to be configured will return an error upon setting.
| ||||
| CextremePethSlotPSUActive | 1.3.6.1.4.1.1916.1.27.1.2.1.13 | INTEGER | RO | |
column · INTEGER · read-only · current Inline Power supply status indication for the slot. Indicates which PSU is currently active. In the case of a failover a none indication can occur until one of the PSU has finished powering up.
| ||||
| CextremePethSlotMeasuredPower | 1.3.6.1.4.1.1916.1.27.1.2.1.14 | Gauge32 | RO | |
column · Gauge32 · read-only · current The measured amount of power for all PoE device on the slot.
| ||||
| CextremePethSlotMainPseIndex | 1.3.6.1.4.1.1916.1.27.1.2.1.15 | Integer32 | RO | |
column · Integer32 · read-only · current The index into the PethMainPseTable. Provides the mapping of the slot identifier to pethMainPseGroupIndex. | ||||
| CextremePethSlotPerpetualPoe | 1.3.6.1.4.1.1916.1.27.1.2.1.16 | TruthValue | RW | |
column · TruthValue · read-write · current true (1) Enable the Perpetual PoE function in the slot. false(2) Disable the Perpetual PoE function in the slot. | ||||
| CextremePethSlotFastPoe | 1.3.6.1.4.1.1916.1.27.1.2.1.17 | TruthValue | RW | |
column · TruthValue · read-write · current true (1) Enable the Fast PoE function in the slot. false(2) Disable the Fast PoE function in the slot. | ||||
| NextremePethPort | 1.3.6.1.4.1.1916.1.27.2 | |||
| TextremePethPsePortTable | 1.3.6.1.4.1.1916.1.27.2.1 | NA | ||
table · not-accessible · current A table of objects that extends the standard pethPsePortTable. | ||||
| RextremePethPsePortEntry | 1.3.6.1.4.1.1916.1.27.2.1.1 | NA | ||
row · not-accessible · current A set of objects that display and control the power characteristics of a powerEthernet PSE port. This table extends the standard pethPsePortTable. | ||||
| CextremePethPortOperatorLimit | 1.3.6.1.4.1.1916.1.27.2.1.1.1 | Integer32 (3000..90000) | RW | |
column · Integer32 (3000..90000) · read-write · current Controls individual port maximum power level.
| ||||
| CextremePethPortReservedBudget | 1.3.6.1.4.1.1916.1.27.2.1.1.2 | Integer32 (0..90000) | RW | |
column · Integer32 (0..90000) · read-write · current Controls individual port maximum power level. Value is 0 or in the range of 3000..90000
| ||||
| CextremePethPortViolationPrecedence | 1.3.6.1.4.1.1916.1.27.2.1.1.3 | INTEGER | RW | |
column · INTEGER · read-write · current Sets the violation precedence for the specified ports. A value of advertised-class will remove/deny power in the case an 802.3af compliant PD consumes power beyond its advertised class limit. A value of operator-limit will remove/deny power should the PD consume power beyond the configured operator-limit. A value of max-class-operator will remove/deny power if the PD consumes power beyond the maximum of the detected class limit and the operator-limit. A value of none will remove/deny power in case the PD device exceeds the maximum allowable wattage according to regulatory maximum of 20 W. Default is max-class-operator which allows operation of both 802.3af compliant and legacy PDs.
| ||||
| CextremePethPortClearFault | 1.3.6.1.4.1.1916.1.27.2.1.1.4 | INTEGER | RW | |
column · INTEGER · read-write · current Clears the fault condition. Reading always returns clear(2).
| ||||
| CextremePethPortResetPower | 1.3.6.1.4.1.1916.1.27.2.1.1.5 | INTEGER | RW | |
column · INTEGER · read-write · current Resets the power on the port. Reading always returns clear(2)
| ||||
| CextremePethPortMeasuredPower | 1.3.6.1.4.1.1916.1.27.2.1.1.6 | Gauge32 | RO | |
column · Gauge32 · read-only · current The amount of power consumed on the port expressed in Milliwatts.
| ||||
| CextremePethPortDetectionType | 1.3.6.1.4.1.1916.1.27.2.1.1.7 | INTEGER | RW | |
column · INTEGER · read-write · current This object is used to specify the mechanism used to detect powered ethernet devices attached to a powered ethernet port. This object should only be instantiated for ports that that support powered ethernet.
| ||||
| CextremePethPortMeasuredVoltage | 1.3.6.1.4.1.1916.1.27.2.1.1.8 | Gauge32 | RO | |
column · Gauge32 · read-only · current Measured Port Voltage. When the port is not supplying power, the value will be 0.
| ||||
| CextremePethPortMeasuredCurrent | 1.3.6.1.4.1.1916.1.27.2.1.1.9 | Gauge32 | RO | |
column · Gauge32 · read-only · current Measured Port Current. When the port is not supplying power, the value will be 0.
| ||||
| CextremePethPortFastPoeEnable | 1.3.6.1.4.1.1916.1.27.2.1.1.10 | TruthValue | RW | |
column · TruthValue · read-write · current true (1) Enable Fast PoE function on this port. false(2) Disable Fast PoE function on this port. | ||||
| CextremePethPortIfIndex | 1.3.6.1.4.1.1916.1.27.2.1.1.11 | Integer32 | RO | |
column · Integer32 · read-only · current The value of the instance of the ifIndex object, defined in MIB-II, for the interface corresponding to this port. | ||||
| NextremePethSystem | 1.3.6.1.4.1.1916.1.27.4 | |||
| SextremePethSystemAdminEnable | 1.3.6.1.4.1.1916.1.27.4.1 | INTEGER | RW | |
scalar · INTEGER · read-write · current Controls whether inline power is provided by the system.
| ||||
| SextremePethSystemDisconnectPrecedence | 1.3.6.1.4.1.1916.1.27.4.2 | INTEGER | RW | |
scalar · INTEGER · read-write · current Controls the disconnect function of power management.
When the power drain exceeds the available power budget,
due to a rise in power consumption after power is allocated
to the ports, the PoE controller disconnects one of the ports
to prevent overload on the power supply. There are two controls:
Lowest-priority: next port connected causes a shutdown of the
lowest priority port.
Deny-port: next port is denied power, regardless of priority.
| ||||
| SextremePethSystemUsageThreshold | 1.3.6.1.4.1.1916.1.27.4.3 | Integer32 (1..99) | RW | |
scalar · Integer32 (1..99) · read-write · current The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded.
| ||||
| SextremePethSystemPowerSupplyMode | 1.3.6.1.4.1.1916.1.27.4.4 | INTEGER | RW | |
scalar · INTEGER · read-write · current Controls whether the power supply operate in redundant or load-sharing mode. Systems which do not provide redundant or load-sharing operations will return an error on setting, and notApplicable on read.
| ||||
| SextremePethSystemLegacyEnable | 1.3.6.1.4.1.1916.1.27.4.5 | INTEGER | RW | |
scalar · INTEGER · read-write · current Controls whether legacy is supported by the system. This is only supported on S300-24 stackables currently.
| ||||