EXTREME-NP-MIB
Extreme NetworksExtreme NP objects: NP card information
snmptranslate -m EXTREME-NP-MIB -Tpsnmpwalk -v2c -c <community> -m EXTREME-NP-MIB <host> 1.3.6.1.4.1.1916.1.21Imports
| EXTREME-BASE-MIB | extremeAgent |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IextremeNPMib | 1.3.6.1.4.1.1916.1.21 | |||
identity Extreme NP objects: NP card information | ||||
| NextremeNPModule | 1.3.6.1.4.1.1916.1.21.1 | |||
| TextremeNPModuleTable | 1.3.6.1.4.1.1916.1.21.1.1 | NA | ||
table · not-accessible · current A table containing information about each Intelligent module in the chassis. | ||||
| RextremeNPModuleEntry | 1.3.6.1.4.1.1916.1.21.1.1.1 | NA | ||
row · not-accessible · current A table entry containing information about the intelligent modules configured in the chassis. This table does not contain rows for the slots which do not have a network processor based module. | ||||
| CextremeNPModuleSlotNumber | 1.3.6.1.4.1.1916.1.21.1.1.1.1 | INTEGER (1..8) | RO | |
column · INTEGER (1..8) · read-only · current A unique integer identifying the particular slot in the chassis. | ||||
| CextremeNPModuleDescription | 1.3.6.1.4.1.1916.1.21.1.1.1.2 | DisplayString (SIZE (0..32)) | RO | |
column · DisplayString (SIZE (0..32)) · read-only · current A description of the particular slot in the chassis. | ||||
| CextremeNPModuleCurrentSoftware | 1.3.6.1.4.1.1916.1.21.1.1.1.3 | DisplayString (SIZE (0..160)) | RO | |
column · DisplayString (SIZE (0..160)) · read-only · current The version of the software currently running on the module. | ||||
| CextremeNPModulePrimarySoftware | 1.3.6.1.4.1.1916.1.21.1.1.1.4 | DisplayString (SIZE (0..160)) | RO | |
column · DisplayString (SIZE (0..160)) · read-only · current The version of software in the primary image of the module. | ||||
| CextremeNPModuleSecondarySoftware | 1.3.6.1.4.1.1916.1.21.1.1.1.5 | DisplayString (SIZE (0..160)) | RO | |
column · DisplayString (SIZE (0..160)) · read-only · current The version of software in the secondary image of the module. | ||||
| CextremeNPModuleBootromVersion | 1.3.6.1.4.1.1916.1.21.1.1.1.6 | DisplayString (SIZE (0..80)) | RO | |
column · DisplayString (SIZE (0..80)) · read-only · current The version of bootrom that the module will use when restarting. | ||||
| CextremeNPModuleProcessorState | 1.3.6.1.4.1.1916.1.21.1.1.1.7 | OCTET STRING (SIZE (8)) | RO | |
column · OCTET STRING (SIZE (8)) · read-only · current An Octet String indicating the status of the various processors on an Intelligent Module. Each byte in the Octet String represents state for one processor. For the Avalanche based PoS and ARM modules, the first byte (from MSB) represents the state of the General Purpose Processor, the second byte the state of Network Processor 1, and the third byte the state of Network Processor 2 and so on. A value of 0 in each byte indicates that the Processor is not operational, while a value 1 indicates that it is. | ||||
| NextremeSMAModule | 1.3.6.1.4.1.1916.1.21.2 | |||
| TextremeSMATable | 1.3.6.1.4.1.1916.1.21.2.1 | NA | ||
table · not-accessible · current A table containing information about each SMA module in the chassis. | ||||
| RextremeSMAEntry | 1.3.6.1.4.1.1916.1.21.2.1.1 | NA | ||
row · not-accessible · current A table entry containing information about the SMA modules configured in the chassis. This table does not contain rows for the slots which do not have an SMA module.
| ||||
| CextremeSMASlotNumber | 1.3.6.1.4.1.1916.1.21.2.1.1.1 | INTEGER (1..8) | RO | |
column · INTEGER (1..8) · read-only · current A unique integer identifying the particular slot in the chassis. | ||||
| CextremeSMAProtocolVersion | 1.3.6.1.4.1.1916.1.21.2.1.1.2 | INTEGER (1..255) | RO | |
column · INTEGER (1..255) · read-only · current Protocol version. | ||||
| CextremeSMAServiceVersion | 1.3.6.1.4.1.1916.1.21.2.1.1.3 | DisplayString (SIZE (0..128)) | RO | |
column · DisplayString (SIZE (0..128)) · read-only · current Service release version. | ||||
| CextremeSMAUpTime | 1.3.6.1.4.1.1916.1.21.2.1.1.4 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Continuous operating time of the module in seconds. | ||||
| CextremeSMACpuUtilization | 1.3.6.1.4.1.1916.1.21.2.1.1.5 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Percentage of CPU utilized in the last 5 seconds. | ||||
| CextremeSMAMemUtilization | 1.3.6.1.4.1.1916.1.21.2.1.1.6 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Percentage of memory utilized. | ||||
| CextremeSMAQosBroadcaster | 1.3.6.1.4.1.1916.1.21.2.1.1.7 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current 60 second rolling average of %QoS. Number of bytes received / Number of bytes expected per duration. Note: this can potentially exceed 100%. | ||||
| CextremeSMANumFromBroadcaster | 1.3.6.1.4.1.1916.1.21.2.1.1.8 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The total number of broadcasters sending streams. | ||||
| CextremeSMANumToListener | 1.3.6.1.4.1.1916.1.21.2.1.1.9 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The total number of listeners connected. | ||||
| CextremeSMABytesBroadcaster | 1.3.6.1.4.1.1916.1.21.2.1.1.10 | Counter64 | RO | |
column · Counter64 · read-only · current The total number of media bytes received from the broadcasters. | ||||
| CextremeSMABytesListener | 1.3.6.1.4.1.1916.1.21.2.1.1.11 | Counter64 | RO | |
column · Counter64 · read-only · current The total number of data bytes sent to listeners. | ||||
| NextremeATMModule | 1.3.6.1.4.1.1916.1.21.3 | |||
| TextremeATMCellPduTable | 1.3.6.1.4.1.1916.1.21.3.1 | NA | ||
table · not-accessible · current A table containing information about each ATM module in the chassis. | ||||
| RextremeATMCellPduEntry | 1.3.6.1.4.1.1916.1.21.3.1.1 | NA | ||
row · not-accessible · current A table entry containing information about the ATM modules configured in the chassis. This table does not contain rows for the slots which do not have an ATM module.
| ||||
| CextremeATMPortNumber | 1.3.6.1.4.1.1916.1.21.3.1.1.1 | INTEGER (1..64) | RO | |
column · INTEGER (1..64) · read-only · current A unique integer identifying the particular port number in the chassis. | ||||
| CextremeATMRxCell | 1.3.6.1.4.1.1916.1.21.3.1.1.2 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number of ATM cell Received. | ||||
| CextremeATMTxCell | 1.3.6.1.4.1.1916.1.21.3.1.1.3 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number of ATM cell Transmitted. | ||||
| CextremeATMRxCellHecError | 1.3.6.1.4.1.1916.1.21.3.1.1.4 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number of received cells with HEC error. | ||||
| CextremeATMRxCellError | 1.3.6.1.4.1.1916.1.21.3.1.1.5 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number of received cells discarded due to other error. | ||||
| CextremeATMRxAAL5Pdu | 1.3.6.1.4.1.1916.1.21.3.1.1.6 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number AAL-5 PDU Received. | ||||
| CextremeATMTxAAL5Pdu | 1.3.6.1.4.1.1916.1.21.3.1.1.7 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number AAL-5 PDU Transmitted. | ||||
| CextremeATMRxAAL5Bytes | 1.3.6.1.4.1.1916.1.21.3.1.1.8 | Counter64 | RO | |
column · Counter64 · read-only · current The number AAL-5 PDU Octetd Received. | ||||
| CextremeATMTxAAL5Bytes | 1.3.6.1.4.1.1916.1.21.3.1.1.9 | Counter64 | RO | |
column · Counter64 · read-only · current The number AAL-5 PDU Octetd Transmitted. | ||||
| CextremeATMPortStatus | 1.3.6.1.4.1.1916.1.21.3.1.1.10 | DisplayString (SIZE (0..4)) | RO | |
column · DisplayString (SIZE (0..4)) · read-only · current ATM port status. | ||||
| TextremeATMVpiVciTable | 1.3.6.1.4.1.1916.1.21.3.2 | NA | ||
table · not-accessible · current A table containing information about each ATM module in the chassis. | ||||
| RextremeATMVpiVciEntry | 1.3.6.1.4.1.1916.1.21.3.2.1 | NA | ||
row · not-accessible · current A table entry containing information about the ATM modules configured in the chassis. This table does not contain rows for the slots which do not have an ATM module. | ||||
| CextremeATMPortNum | 1.3.6.1.4.1.1916.1.21.3.2.1.1 | INTEGER (1..64) | RO | |
column · INTEGER (1..64) · read-only · current A unique integer identifying the particular port number in the chassis. | ||||
| CextremeATMPvc | 1.3.6.1.4.1.1916.1.21.3.2.1.2 | INTEGER (1..3072) | RO | |
column · INTEGER (1..3072) · read-only · current A unique integer identifying the pvc number configured on a single port. | ||||
| CextremeATMVpi | 1.3.6.1.4.1.1916.1.21.3.2.1.3 | INTEGER (0..15) | RO | |
column · INTEGER (0..15) · read-only · current A unique integer identifying the VPI value of the configured PVCs. | ||||
| CextremeATMVci | 1.3.6.1.4.1.1916.1.21.3.2.1.4 | INTEGER (17..4095) | RO | |
column · INTEGER (17..4095) · read-only · current A unique integer identifying the VCI value of the configured PVCs. | ||||
| NextremeMplsModule | 1.3.6.1.4.1.1916.1.21.4 | |||
| TextremeMplsTlsTable | 1.3.6.1.4.1.1916.1.21.4.1 | NA | ||
table · not-accessible · current A table containing information about each MPLS TLS tunnel in the chassis. | ||||
| RextremeMplsTlsEntry | 1.3.6.1.4.1.1916.1.21.4.1.1 | NA | ||
row · not-accessible · current A table entry containing information about the MPLS TLS tunnel.
| ||||
| CextremeMplsTlsNum | 1.3.6.1.4.1.1916.1.21.4.1.1.1 | INTEGER (1..16384) | RO | |
column · INTEGER (1..16384) · read-only · current An index used to reference each configured TLS tunnel. | ||||
| CextremeMplsTlsName | 1.3.6.1.4.1.1916.1.21.4.1.1.2 | DisplayString (SIZE (0..31)) | RO | |
column · DisplayString (SIZE (0..31)) · read-only · current The user defined TLS tunnel identifier name. | ||||
| CextremeMplsTlsLocalIpAddr | 1.3.6.1.4.1.1916.1.21.4.1.1.3 | IpAddress | RO | |
column · IpAddress · read-only · current The TLS tunnel local endpoint IP address, only valid if TLS tunnel is Dynamic. Otherwise, this field is set to zero. | ||||
| CextremeMplsTlsPeerIpAddr | 1.3.6.1.4.1.1916.1.21.4.1.1.4 | IpAddress | RO | |
column · IpAddress · read-only · current The TLS tunnel peer endpoint IP address. | ||||
| CextremeMplsTlsLocalVlanID | 1.3.6.1.4.1.1916.1.21.4.1.1.5 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The local Egress Vlan ID. | ||||
| CextremeMplsTlsLocalVlanName | 1.3.6.1.4.1.1916.1.21.4.1.1.6 | DisplayString (SIZE (0..31)) | RO | |
column · DisplayString (SIZE (0..31)) · read-only · current The local Egress Vlan Name. | ||||
| CextremeMplsTlsDynamic | 1.3.6.1.4.1.1916.1.21.4.1.1.7 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current Flag indicating that the TLS tunnel is Dynamic. If set, the TLS tunnel is dynamically signaled. If zero, the TLS tunnel is statically configured. | ||||
| CextremeMplsTlsType | 1.3.6.1.4.1.1916.1.21.4.1.1.8 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The TLS tunnel type 0- MPLS, Static 1- MPLS, Martini . | ||||
| CextremeMplsTlsVcID | 1.3.6.1.4.1.1916.1.21.4.1.1.9 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The configured VC ID, only valid if TLS tunnel is Dynamic. Otherwise, this field is set to zero. | ||||
| CextremeMplsTlsLocalGroupID | 1.3.6.1.4.1.1916.1.21.4.1.1.10 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The configured Local Group ID, only valid if TLS tunnel is Dynamic. Otherwise, this field is set to zero. | ||||
| CextremeMplsTlsRemoteGroupID | 1.3.6.1.4.1.1916.1.21.4.1.1.11 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The learned Remote Group ID, only valid if TLS tunnel is Dynamic. Otherwise, this field is set to zero. | ||||
| CextremeMplsTlsIngressVcLabel | 1.3.6.1.4.1.1916.1.21.4.1.1.12 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The TLS tunnel VLAN Ingress Label. If the TLS tunnel is Static, this value is configured. If TLS tunnel is Dynamic, this value is dynamically allocated from the TLS label range and signaled to the TLS tunnel peer. | ||||
| CextremeMplsTlsEgressVcLabel | 1.3.6.1.4.1.1916.1.21.4.1.1.13 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The TLS tunnel VLAN Egress Label. If the TLS tunnel is Static, this value is configured. If TLS tunnel is Dynamic, this value is learned from the TLS tunnel peer. | ||||
| CextremeMplsTlsVcState | 1.3.6.1.4.1.1916.1.21.4.1.1.14 | DisplayString (SIZE (0..79)) | RO | |
column · DisplayString (SIZE (0..79)) · read-only · current The TLS tunnel VC state. Valid states include: - Idle - No LSP Available - Waiting for LDP session - Pending label mapping - Pending local configuration - MTU incompatibility - Up - Unknown - Error .. General failure - Error .. Targeted LDP session failure - Error .. Bridge configuration problem - Error .. Ingress label allocation failure - Error .. Failure sending TLS label mapping - Error .. Patricia tree insertion failure - Error .. Failure programming TLS hardware - Error .. MPLS not initialized - Error .. Unknown. | ||||
| CextremeMplsTlsPacketTx | 1.3.6.1.4.1.1916.1.21.4.1.1.15 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number of Packets Transmitted on this TLS tunnel. | ||||
| CextremeMplsTlsPacketRx | 1.3.6.1.4.1.1916.1.21.4.1.1.16 | Unsigned32 | RO | |
column · Unsigned32 · read-only · current The number of Packets Received on this TLS tunnel. | ||||
| CextremeMplsTlsOctetTx | 1.3.6.1.4.1.1916.1.21.4.1.1.17 | Counter64 | RO | |
column · Counter64 · read-only · current The number of Octets Transmitted on this TLS tunnel. | ||||
| CextremeMplsTlsOctetRx | 1.3.6.1.4.1.1916.1.21.4.1.1.18 | Counter64 | RO | |
column · Counter64 · read-only · current The number of Octets Received on this TLS tunnel. | ||||