EXTREME-BASE-MIB
Extreme NetworksExtreme Base MIB
snmptranslate -m EXTREME-BASE-MIB -Tpsnmpwalk -v2c -c <community> -m EXTREME-BASE-MIB <host> 1.3.6.1.4.1.1916Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Iextremenetworks | 1.3.6.1.4.1.1916 | |||
identity Extreme Base MIB | ||||
| NextremeV1Traps | 1.3.6.1.4.1.1916.0 | |||
| NextremeAgent | 1.3.6.1.4.1.1916.1 | |||
| NextremeSystem | 1.3.6.1.4.1.1916.1.1 | |||
| NextremeVlan | 1.3.6.1.4.1.1916.1.2 | |||
| NextremeQos | 1.3.6.1.4.1.1916.1.3 | |||
| NextremePort | 1.3.6.1.4.1.1916.1.4 | |||
| NextremeVC | 1.3.6.1.4.1.1916.1.5 | |||
| NextremeTrapPoll | 1.3.6.1.4.1.1916.1.6 | |||
| NextremeQosPolicy | 1.3.6.1.4.1.1916.1.7 | |||
| NextremeDlcs | 1.3.6.1.4.1.1916.1.8 | |||
| NextremeFileTransfer | 1.3.6.1.4.1.1916.1.10 | |||
| NextremeRtStats | 1.3.6.1.4.1.1916.1.11 | |||
| NextremeEsrp | 1.3.6.1.4.1.1916.1.12 | |||
| NextremeEdp | 1.3.6.1.4.1.1916.1.13 | |||
| NextremeSlb | 1.3.6.1.4.1.1916.1.14 | |||
| NextremeOspf | 1.3.6.1.4.1.1916.1.15 | |||
| NextremeFdb | 1.3.6.1.4.1.1916.1.16 | |||
| NextremeStp | 1.3.6.1.4.1.1916.1.17 | |||
| NextremeEaps | 1.3.6.1.4.1.1916.1.18 | |||
| NextremeLacp | 1.3.6.1.4.1.1916.1.19 | |||
| NextremePOSMib | 1.3.6.1.4.1.1916.1.20 | |||
| NextremeNPMib | 1.3.6.1.4.1.1916.1.21 | |||
| NextremeNetFlow | 1.3.6.1.4.1.1916.1.22 | |||
| NextremeSnmpv3 | 1.3.6.1.4.1.1916.1.23 | |||
| NextremeCable | 1.3.6.1.4.1.1916.1.24 | |||
| NextremeWireless | 1.3.6.1.4.1.1916.1.25 | |||
| NextremeAP | 1.3.6.1.4.1.1916.1.25.1 | |||
| NextremeLAC | 1.3.6.1.4.1.1916.1.25.2 | |||
| NextremeServices | 1.3.6.1.4.1.1916.1.26 | |||
| NextremePoE | 1.3.6.1.4.1.1916.1.27 | |||
| NextremeDosMib | 1.3.6.1.4.1.1916.1.28 | |||
| NextremeEnhDosMib | 1.3.6.1.4.1.1916.1.29 | |||
| NextremeClearflow | 1.3.6.1.4.1.1916.1.30 | |||
| NextremeEntity | 1.3.6.1.4.1.1916.1.31 | |||
| NextremeSwMonitor | 1.3.6.1.4.1.1916.1.32 | |||
| NextremeStackable | 1.3.6.1.4.1.1916.1.33 | |||
| NextremeIpSecurity | 1.3.6.1.4.1.1916.1.34 | |||
| NextremeUpm | 1.3.6.1.4.1.1916.1.35 | |||
| NextremeIdMgr | 1.3.6.1.4.1.1916.1.36 | |||
| NextremeMplsMIB | 1.3.6.1.4.1.1916.1.37 | |||
| NextremeHclag | 1.3.6.1.4.1.1916.1.38 | |||
| NextremeVM | 1.3.6.1.4.1.1916.1.39 | |||
| NextremeAutoProvision | 1.3.6.1.4.1.1916.1.40 | |||
| NextremeMlag | 1.3.6.1.4.1.1916.1.41 | |||
| NextremeCfgMgmt | 1.3.6.1.4.1.1916.1.42 | |||
| NextremeBfd | 1.3.6.1.4.1.1916.1.43 | |||
| NextremeMacAuthMIB | 1.3.6.1.4.1.1916.1.44 | |||
| NextremePbbMib | 1.3.6.1.4.1.1916.1.45 | |||
| NextremeErps | 1.3.6.1.4.1.1916.1.46 | |||
| NextremeCfm | 1.3.6.1.4.1.1916.1.47 | |||
| NextremeAcl | 1.3.6.1.4.1.1916.1.48 | |||
| NextremeVrrpMIB | 1.3.6.1.4.1.1916.1.49 | |||
| NextremeOspfv3MIB | 1.3.6.1.4.1.1916.1.50 | |||
| NextremeBgp4V2 | 1.3.6.1.4.1.1916.1.51 | |||
| NextremeBgp4V2TC | 1.3.6.1.4.1.1916.1.52 | |||
| NextremeRemoteConnectionMIB | 1.3.6.1.4.1.1916.1.53 | |||
| NextremeBfdMIB | 1.3.6.1.4.1.1916.1.55 | |||
| NextremeMCTClusterMIB | 1.3.6.1.4.1.1916.1.56 | |||
| NextremeMaintModeMIB | 1.3.6.1.4.1.1916.1.57 | |||
| NextremeThresholdMonitorMIB | 1.3.6.1.4.1.1916.1.58 | |||
| NextremeCertExpiryMIB | 1.3.6.1.4.1.1916.1.59 | |||
| NextremeSystemSensorMIB | 1.3.6.1.4.1.1916.1.60 | |||
| NextremeUserMIB | 1.3.6.1.4.1.1916.1.61 | |||
| NextremeInterfaceStatsMIB | 1.3.6.1.4.1.1916.1.62 | |||
| NextremeMLAGMIB | 1.3.6.1.4.1.1916.1.63 | |||
| NextremeInternal | 1.3.6.1.4.1.1916.1.1000 | |||
| NextremeProduct | 1.3.6.1.4.1.1916.2 | |||
| Nsummit1 | 1.3.6.1.4.1.1916.2.1 | |||
| Nsummit2 | 1.3.6.1.4.1.1916.2.2 | |||
| Nsummit3 | 1.3.6.1.4.1.1916.2.3 | |||
| Nsummit4 | 1.3.6.1.4.1.1916.2.4 | |||
| Nsummit4fx | 1.3.6.1.4.1.1916.2.5 | |||
| Nsummit48 | 1.3.6.1.4.1.1916.2.6 | |||
| Nsummit24 | 1.3.6.1.4.1.1916.2.7 | |||
| NblackDiamond6800 | 1.3.6.1.4.1.1916.2.8 | |||
| NblackDiamond6808 | 1.3.6.1.4.1.1916.2.11 | |||
| Nsummit7iSX | 1.3.6.1.4.1.1916.2.12 | |||
| Nsummit7iTX | 1.3.6.1.4.1.1916.2.13 | |||
| Nsummit1iTX | 1.3.6.1.4.1.1916.2.14 | |||
| Nsummit5i | 1.3.6.1.4.1.1916.2.15 | |||
| Nsummit48i | 1.3.6.1.4.1.1916.2.16 | |||
| Nalpine3808 | 1.3.6.1.4.1.1916.2.17 | |||
| Nsummit1iSX | 1.3.6.1.4.1.1916.2.19 | |||
| Nalpine3804 | 1.3.6.1.4.1.1916.2.20 | |||
| Nsummit5iLX | 1.3.6.1.4.1.1916.2.21 | |||
| Nsummit5iTX | 1.3.6.1.4.1.1916.2.22 | |||
| NenetSwitch24Port | 1.3.6.1.4.1.1916.2.23 | |||
| NblackDiamond6816 | 1.3.6.1.4.1.1916.2.24 | |||
| Nsummit24e3 | 1.3.6.1.4.1.1916.2.25 | |||
| Nalpine3802 | 1.3.6.1.4.1.1916.2.26 | |||
| NblackDiamond6804 | 1.3.6.1.4.1.1916.2.27 | |||
| Nsummit48si | 1.3.6.1.4.1.1916.2.28 | |||
| NsummitPx1 | 1.3.6.1.4.1.1916.2.30 | |||
| Nsummit24e2TX | 1.3.6.1.4.1.1916.2.40 | |||
| Nsummit24e2SX | 1.3.6.1.4.1.1916.2.41 | |||
| Nsummit200-24 | 1.3.6.1.4.1.1916.2.53 | |||
| Nsummit200-48 | 1.3.6.1.4.1.1916.2.54 | |||
| Nsummit300-48 | 1.3.6.1.4.1.1916.2.55 | |||
| Nbd10808 | 1.3.6.1.4.1.1916.2.56 | |||
| Nsummit400-48t | 1.3.6.1.4.1.1916.2.58 | |||
| Nsummit300-24 | 1.3.6.1.4.1.1916.2.61 | |||
| Nbd8810 | 1.3.6.1.4.1.1916.2.62 | |||
| Nsummit400-24t | 1.3.6.1.4.1.1916.2.63 | |||
| Nsummit400-24p | 1.3.6.1.4.1.1916.2.64 | |||
| NsummitX450-24x | 1.3.6.1.4.1.1916.2.65 | |||
| NsummitX450-24t | 1.3.6.1.4.1.1916.2.66 | |||
| NsummitStack | 1.3.6.1.4.1.1916.2.67 | |||
| NsummitWM100 | 1.3.6.1.4.1.1916.2.68 | |||
| NsummitWM1000 | 1.3.6.1.4.1.1916.2.69 | |||
| Nsummit200-24fx | 1.3.6.1.4.1.1916.2.70 | |||
| NsummitX450a-24t | 1.3.6.1.4.1.1916.2.71 | |||
| NsummitX450e-24p | 1.3.6.1.4.1.1916.2.72 | |||
| Nbd8806 | 1.3.6.1.4.1.1916.2.74 | |||
| Naltitude350 | 1.3.6.1.4.1.1916.2.75 | |||
| NsummitX450a-48t | 1.3.6.1.4.1.1916.2.76 | |||
| Nbd12804 | 1.3.6.1.4.1.1916.2.77 | |||
| NsummitX450e-48p | 1.3.6.1.4.1.1916.2.79 | |||
| NsummitX450a-24tDC | 1.3.6.1.4.1.1916.2.80 | |||
| NsummitX450a-24xDC | 1.3.6.1.4.1.1916.2.82 | |||
| NsentriantCE150 | 1.3.6.1.4.1.1916.2.83 | |||
| NsummitX450a-24x | 1.3.6.1.4.1.1916.2.84 | |||
| Nbd12802 | 1.3.6.1.4.1.1916.2.85 | |||
| Naltitude300 | 1.3.6.1.4.1.1916.2.86 | |||
| NsummitX450a-48tDC | 1.3.6.1.4.1.1916.2.87 | |||
| NsummitX250-24t | 1.3.6.1.4.1.1916.2.88 | |||
| NsummitX250-24p | 1.3.6.1.4.1.1916.2.89 | |||
| NsummitX250-24x | 1.3.6.1.4.1.1916.2.90 | |||
| NsummitX250-48t | 1.3.6.1.4.1.1916.2.91 | |||
| NsummitX250-48p | 1.3.6.1.4.1.1916.2.92 | |||
| NsummitVer2Stack | 1.3.6.1.4.1.1916.2.93 | |||
| NsummitWM200 | 1.3.6.1.4.1.1916.2.94 | |||
| NsummitWM2000 | 1.3.6.1.4.1.1916.2.95 | |||
| NsummitWM100Lite | 1.3.6.1.4.1.1916.2.96 | |||
| NsummitX250-24tDC | 1.3.6.1.4.1.1916.2.97 | |||
| NsummitX250-24xDC | 1.3.6.1.4.1.1916.2.98 | |||
| NsummitX250-48tDC | 1.3.6.1.4.1.1916.2.99 | |||
| NsummitX150-24t | 1.3.6.1.4.1.1916.2.100 | |||
| NsummitX150-24tDC | 1.3.6.1.4.1.1916.2.101 | |||
| NsummitX150-24p | 1.3.6.1.4.1.1916.2.102 | |||
| NsummitX150-24x | 1.3.6.1.4.1.1916.2.103 | |||
| NsummitX150-24xDC | 1.3.6.1.4.1.1916.2.104 | |||
| NsummitX150-48t | 1.3.6.1.4.1.1916.2.105 | |||
| NsummitX150-48tDC | 1.3.6.1.4.1.1916.2.106 | |||
| NsummitX150-48p | 1.3.6.1.4.1.1916.2.107 | |||
| NsentriantAGSW | 1.3.6.1.4.1.1916.2.108 | |||
| NsentriantAG200 | 1.3.6.1.4.1.1916.2.109 | |||
| NsummitWM20 | 1.3.6.1.4.1.1916.2.110 | |||
| NsummitX350-24t | 1.3.6.1.4.1.1916.2.111 | |||
| NsummitX350-48t | 1.3.6.1.4.1.1916.2.112 | |||
| NsummitX650-24t | 1.3.6.1.4.1.1916.2.113 | |||
| NsummitX650-24x | 1.3.6.1.4.1.1916.2.114 | |||
| NsentriantNG300 | 1.3.6.1.4.1.1916.2.115 | |||
| Naltitude360 | 1.3.6.1.4.1.1916.2.116 | |||
| Naltitude450 | 1.3.6.1.4.1.1916.2.117 | |||
| NsummitX650-24x-SSns | 1.3.6.1.4.1.1916.2.118 | |||
| NsummitX650-24t-SSns | 1.3.6.1.4.1.1916.2.119 | |||
| NsummitX650-24x-SS | 1.3.6.1.4.1.1916.2.120 | |||
| NsummitX650-24t-SS | 1.3.6.1.4.1.1916.2.121 | |||
| NsummitX650-24x-10G8X | 1.3.6.1.4.1.1916.2.122 | |||
| NsummitX650-24t-10G8X | 1.3.6.1.4.1.1916.2.123 | |||
| NsummitX650-24x-SS256 | 1.3.6.1.4.1.1916.2.124 | |||
| NsummitX650-24t-SS256 | 1.3.6.1.4.1.1916.2.125 | |||
| NsummitX650-24x-SS512 | 1.3.6.1.4.1.1916.2.126 | |||
| NsummitX650-24t-SS512 | 1.3.6.1.4.1.1916.2.127 | |||
| Nbd20808 | 1.3.6.1.4.1.1916.2.128 | |||
| Nnwi-e450a | 1.3.6.1.4.1.1916.2.129 | |||
| NsentriantPS200v1 | 1.3.6.1.4.1.1916.2.130 | |||
| NwirelessProducts | 1.3.6.1.4.1.1916.2.131 | |||
| NsummitWM3700 | 1.3.6.1.4.1.1916.2.131.15 | |||
| NsummitWM3600 | 1.3.6.1.4.1.1916.2.131.16 | |||
| NsummitWM3400 | 1.3.6.1.4.1.1916.2.131.18 | |||
| Nbd20804 | 1.3.6.1.4.1.1916.2.132 | |||
| NsummitX480-48t | 1.3.6.1.4.1.1916.2.133 | |||
| NsummitX480-48t-SS | 1.3.6.1.4.1.1916.2.134 | |||
| NsummitX480-48t-10G4X | 1.3.6.1.4.1.1916.2.135 | |||
| NsummitX480-48t-SS128 | 1.3.6.1.4.1.1916.2.136 | |||
| NsummitX480-24x | 1.3.6.1.4.1.1916.2.137 | |||
| NsummitX480-24x-SS | 1.3.6.1.4.1.1916.2.138 | |||
| NsummitX480-24x-10G4X | 1.3.6.1.4.1.1916.2.139 | |||
| NsummitX480-24x-SS128 | 1.3.6.1.4.1.1916.2.140 | |||
| NsummitX480-48x | 1.3.6.1.4.1.1916.2.141 | |||
| NsummitX480-48x-SS | 1.3.6.1.4.1.1916.2.142 | |||
| NsummitX480-48x-10G4X | 1.3.6.1.4.1.1916.2.143 | |||
| NsummitX480-48x-SS128 | 1.3.6.1.4.1.1916.2.144 | |||
| Naltitude3510 | 1.3.6.1.4.1.1916.2.145 | |||
| Naltitude3550 | 1.3.6.1.4.1.1916.2.146 | |||
| Naltitude4610 | 1.3.6.1.4.1.1916.2.148 | |||
| Naltitude4620 | 1.3.6.1.4.1.1916.2.149 | |||
| NsummitX450e-24t | 1.3.6.1.4.1.1916.2.150 | |||
| NsummitX450e-48t | 1.3.6.1.4.1.1916.2.151 | |||
| NsummitX460-24t | 1.3.6.1.4.1.1916.2.152 | |||
| NsummitX460-24p | 1.3.6.1.4.1.1916.2.153 | |||
| NsummitX460-24x | 1.3.6.1.4.1.1916.2.154 | |||
| NsummitX460-48t | 1.3.6.1.4.1.1916.2.155 | |||
| NsummitX460-48p | 1.3.6.1.4.1.1916.2.156 | |||
| NsummitX460-48x | 1.3.6.1.4.1.1916.2.157 | |||
| Naltitude4700 | 1.3.6.1.4.1.1916.2.158 | |||
| NsummitX480-24x-SSV80 | 1.3.6.1.4.1.1916.2.159 | |||
| NsummitX480-48x-SSV80 | 1.3.6.1.4.1.1916.2.160 | |||
| NsummitX480-48t-SSV80 | 1.3.6.1.4.1.1916.2.161 | |||
| NsummitX650-24x-40G4X | 1.3.6.1.4.1.1916.2.162 | |||
| NsummitX650-24t-40G4X | 1.3.6.1.4.1.1916.2.163 | |||
| NsummitX480-24x-40G4X | 1.3.6.1.4.1.1916.2.164 | |||
| NsummitX480-48x-40G4X | 1.3.6.1.4.1.1916.2.165 | |||
| NsummitX480-48t-40G4X | 1.3.6.1.4.1.1916.2.166 | |||
| NsummitX670-48x | 1.3.6.1.4.1.1916.2.167 | |||
| NsummitX670v-48x | 1.3.6.1.4.1.1916.2.168 | |||
| Ne4g-400 | 1.3.6.1.4.1.1916.2.169 | |||
| Nbdx8 | 1.3.6.1.4.1.1916.2.170 | |||
| Ne4g-200 | 1.3.6.1.4.1.1916.2.171 | |||
| NsummitX440-8t | 1.3.6.1.4.1.1916.2.172 | |||
| NsummitX440-8p | 1.3.6.1.4.1.1916.2.173 | |||
| NsummitX440-24t | 1.3.6.1.4.1.1916.2.174 | |||
| NsummitX440-24p | 1.3.6.1.4.1.1916.2.175 | |||
| NsummitX440-48t | 1.3.6.1.4.1.1916.2.176 | |||
| NsummitX440-48p | 1.3.6.1.4.1.1916.2.177 | |||
| NsummitX440-24t-10G | 1.3.6.1.4.1.1916.2.178 | |||
| NsummitX440-24p-10G | 1.3.6.1.4.1.1916.2.179 | |||
| NsummitX440-48t-10G | 1.3.6.1.4.1.1916.2.180 | |||
| NsummitX440-48p-10G | 1.3.6.1.4.1.1916.2.181 | |||
| Nags100-24t | 1.3.6.1.4.1.1916.2.182 | |||
| Nags150-24p | 1.3.6.1.4.1.1916.2.183 | |||
| NsummitX670v-48t | 1.3.6.1.4.1.1916.2.184 | |||
| NsummitX440-L2-24t | 1.3.6.1.4.1.1916.2.185 | |||
| NsummitX440-L2-48t | 1.3.6.1.4.1.1916.2.186 | |||
| Ne4g-200-12x | 1.3.6.1.4.1.1916.2.187 | |||
| NsummitX440-24x | 1.3.6.1.4.1.1916.2.188 | |||
| NsummitX440-24x-10g | 1.3.6.1.4.1.1916.2.189 | |||
| NsummitX430-24t | 1.3.6.1.4.1.1916.2.190 | |||
| NsummitX430-48t | 1.3.6.1.4.1.1916.2.191 | |||
| NsummitX440-24tdc | 1.3.6.1.4.1.1916.2.192 | |||
| NsummitX440-48tdc | 1.3.6.1.4.1.1916.2.193 | |||
| NsummitX770-32q | 1.3.6.1.4.1.1916.2.194 | |||
| NsummitX670G2-48x-4q | 1.3.6.1.4.1.1916.2.195 | |||
| NsummitX670G2-72x | 1.3.6.1.4.1.1916.2.196 | |||
| NsummitX460G2-24t-10G4 | 1.3.6.1.4.1.1916.2.197 | |||
| NsummitX460G2-24p-10G4 | 1.3.6.1.4.1.1916.2.198 | |||
| NsummitX460G2-24x-10G4 | 1.3.6.1.4.1.1916.2.199 | |||
| NsummitX460G2-48t-10G4 | 1.3.6.1.4.1.1916.2.200 | |||
| NsummitX460G2-48p-10G4 | 1.3.6.1.4.1.1916.2.201 | |||
| NsummitX460G2-48x-10G4 | 1.3.6.1.4.1.1916.2.202 | |||
| NsummitX430-8p | 1.3.6.1.4.1.1916.2.203 | |||
| NsummitX430-24p | 1.3.6.1.4.1.1916.2.204 | |||
| NaviatCtr-8440 | 1.3.6.1.4.1.1916.2.205 | |||
| NsummitX450G2-24t-10G4 | 1.3.6.1.4.1.1916.2.206 | |||
| NsummitX450G2-24p-10G4 | 1.3.6.1.4.1.1916.2.207 | |||
| NsummitX450G2-48t-10G4 | 1.3.6.1.4.1.1916.2.208 | |||
| NsummitX450G2-48p-10G4 | 1.3.6.1.4.1.1916.2.209 | |||
| NsummitX450G2-24t-G4 | 1.3.6.1.4.1.1916.2.210 | |||
| NsummitX450G2-24p-G4 | 1.3.6.1.4.1.1916.2.211 | |||
| NsummitX450G2-48t-G4 | 1.3.6.1.4.1.1916.2.212 | |||
| NsummitX450G2-48p-G4 | 1.3.6.1.4.1.1916.2.213 | |||
| NsummitX460G2-24t-G4 | 1.3.6.1.4.1.1916.2.214 | |||
| NsummitX460G2-24p-G4 | 1.3.6.1.4.1.1916.2.215 | |||
| NsummitX460G2-48t-G4 | 1.3.6.1.4.1.1916.2.216 | |||
| NsummitX460G2-48p-G4 | 1.3.6.1.4.1.1916.2.217 | |||
| NoneC-A-600 | 1.3.6.1.4.1.1916.2.218 | |||
| NoneC-V | 1.3.6.1.4.1.1916.2.219 | |||
| NsummitX440G2-48p-10G4 | 1.3.6.1.4.1.1916.2.220 | |||
| NsummitX440G2-48t-10G4 | 1.3.6.1.4.1.1916.2.221 | |||
| NsummitX440G2-48t-10G4-DC | 1.3.6.1.4.1.1916.2.222 | |||
| NsummitX440G2-24p-10G4 | 1.3.6.1.4.1.1916.2.223 | |||
| NsummitX440G2-24t-10G4 | 1.3.6.1.4.1.1916.2.224 | |||
| NsummitX440G2-24t-10G4-DC | 1.3.6.1.4.1.1916.2.225 | |||
| NsummitX440G2-24x-10G4 | 1.3.6.1.4.1.1916.2.226 | |||
| NsummitX440G2-12p-10G4 | 1.3.6.1.4.1.1916.2.227 | |||
| NsummitX440G2-12t-10G4 | 1.3.6.1.4.1.1916.2.228 | |||
| NsummitX440G2-12t8fx-G4 | 1.3.6.1.4.1.1916.2.229 | |||
| NsummitX440G2-24t-G4 | 1.3.6.1.4.1.1916.2.230 | |||
| NsummitX440G2-24fx-G4 | 1.3.6.1.4.1.1916.2.231 | |||
| NsummitX620-16T | 1.3.6.1.4.1.1916.2.232 | |||
| NsummitX620-16P | 1.3.6.1.4.1.1916.2.233 | |||
| NsummitX620-16X | 1.3.6.1.4.1.1916.2.234 | |||
| NsummitX620-8T-2X | 1.3.6.1.4.1.1916.2.235 | |||
| NsummitX620-10X | 1.3.6.1.4.1.1916.2.236 | |||
| NsummitX870-32C | 1.3.6.1.4.1.1916.2.237 | |||
| NsummitX870-96X-8C | 1.3.6.1.4.1.1916.2.238 | |||
| Necos | 1.3.6.1.4.1.1916.2.239 | |||
| Nisw-4P-2-G2 | 1.3.6.1.4.1.1916.2.240 | |||
| Nisw-8P-G4 | 1.3.6.1.4.1.1916.2.241 | |||
| Nisw-4GP-2G-G2 | 1.3.6.1.4.1.1916.2.242 | |||
| Nisw-8GP-G4 | 1.3.6.1.4.1.1916.2.243 | |||
| Nx560-48mp-10GE4-100GE2 | 1.3.6.1.4.1.1916.2.244 | |||
| Nx560-48mt-10GE4-100GE2 | 1.3.6.1.4.1.1916.2.245 | |||
| Nx560-24mp-10GE4-100GE2 | 1.3.6.1.4.1.1916.2.246 | |||
| Nx690-48t-4q-2c | 1.3.6.1.4.1.1916.2.247 | |||
| Nx690-48x-4q-2c | 1.3.6.1.4.1.1916.2.248 | |||
| NextremeSNSxNSSxA | 1.3.6.1.4.1.1916.2.249 | |||
node · current Extreme Management Center Server. Management Center is a key component of Extreme's suite of network management products. | ||||
| NextremeNSxAx20 | 1.3.6.1.4.1.1916.2.250 | |||
node · current Extreme Management Center Server. Management Center is a key component of Extreme's suite of network management products. | ||||
| NextremeNACxAx20 | 1.3.6.1.4.1.1916.2.251 | |||
node · current Extreme Access Control Engine for controlling end system access to the network. It controls network access through Extreme Policy or VLANs based on user, device, location, time, and configuration (health). Supports optional on-board assessment. It is a 1U rack mountable system. | ||||
| NextremeIAxV | 1.3.6.1.4.1.1916.2.252 | |||
node · current Extreme Virtual Access Control Engine for controlling end system access to the network. It controls network access through Extreme Policy or VLANs based on user, device, OS, location, time, and configuration. Supports optional on-board posture assessment. | ||||
| NextremeIAxAx20 | 1.3.6.1.4.1.1916.2.253 | |||
node · current Extreme Access Control Engine for controlling end system access to the network. It controls network access through Extreme Policy or VLANs based on user, device, OS, location, time, and configuration. Supports optional on-board posture assessment. It is a 1U rack mountable system. | ||||
| NextremeIAxAx300 | 1.3.6.1.4.1.1916.2.254 | |||
node · current Extreme Access Control Engine for controlling end system access to the network. It controls network access through Extreme Policy or VLANs based on user, device, OS, location, time, and configuration. Supports optional on-board posture assessment. It is a 1U rack mountable system. | ||||
| NextremePVxV | 1.3.6.1.4.1.1916.2.255 | |||
node · current Extreme Virtual Application Analytics Engine. This appliance provides the engine to monitor and classify layer 7 application information based on data from Extreme switches and report information to ExtremeControl where applications are managed. | ||||
| NextremePVxAx300 | 1.3.6.1.4.1.1916.2.256 | |||
node · current Extreme Application Analytics Engine. This appliance provides the engine to monitor and classify layer 7 application information based on data from Extreme switches and report information to ExtremeControl where applications are managed. | ||||
| NsummitX460-G2-16mp-32p-10GE4 | 1.3.6.1.4.1.1916.2.257 | |||
| NsummitX460G2-24p-24hp | 1.3.6.1.4.1.1916.2.258 | |||
| NsummitX460G2-24t-24ht | 1.3.6.1.4.1.1916.2.259 | |||
| Nextreme210-12t-GE2 | 1.3.6.1.4.1.1916.2.260 | |||
node · current Extreme 210-Series 12 port 10/100/1000BASE-T, 2 1GbE SFP ports, 1 Fixed AC PSU, L2 Switching | ||||
| Nextreme210-12p-GE2 | 1.3.6.1.4.1.1916.2.261 | |||
node · current Extreme 210-Series 12 port 10/100/1000BASE-T PoE+, 2 1GbE SFP ports, 1 Fixed AC PSU, L2 Switching | ||||
| Nextreme210-24t-GE2 | 1.3.6.1.4.1.1916.2.262 | |||
node · current Extreme 210-Series 24 port 10/100/1000BASE-T, 2 1GbE SFP ports, 1 Fixed AC PSU, L2 Switching | ||||
| Nextreme210-24p-GE2 | 1.3.6.1.4.1.1916.2.263 | |||
node · current Extreme 210-Series 24 port 10/100/1000BASE-T PoE+, 2 1GbE SFP ports, 1 Fixed AC PSU, L2 Switching | ||||
| Nextreme210-48t-GE4 | 1.3.6.1.4.1.1916.2.264 | |||
node · current Extreme 210-Series 48 port 10/100/1000BASE-T, 4 1GbE SFP ports, 1 Fixed AC PSU, L2 Switching | ||||
| Nextreme210-48p-GE4 | 1.3.6.1.4.1.1916.2.265 | |||
node · current Extreme 210-Series 48 port 10/100/1000BASE-T PoE+, 4 1GbE SFP ports, 1 Fixed AC PSU, L2 Switching | ||||
| Nextreme220-12t-10GE2 | 1.3.6.1.4.1.1916.2.266 | |||
node · current Extreme 220-Series 12 port 10/100/1000BASE-T, 2 10GbE SFP+ ports, 1 Fixed AC PSU, L3 Switching | ||||
| Nextreme220-12p-10GE2 | 1.3.6.1.4.1.1916.2.267 | |||
node · current Extreme 220-Series 12 port 10/100/1000BASE-T PoE+, 2 10GbE SFP+ ports, 1 Fixed AC PSU, L3 Switching | ||||
| Nextreme220-24t-10GE2 | 1.3.6.1.4.1.1916.2.268 | |||
node · current Extreme 220-Series 24 port 10/100/1000BASE-T, 2 10GbE SFP+ ports, 1 Fixed AC PSU, 1 RPS port, L3 Switching | ||||
| Nextreme220-24p-10GE2 | 1.3.6.1.4.1.1916.2.269 | |||
node · current Extreme 220-Series 24 port 10/100/1000BASE-T PoE+, 2 10GbE SFP+ ports, 1 Fixed AC PSU, 1 RPS port, L3 Switching | ||||
| Nextreme220-48t-10GE4 | 1.3.6.1.4.1.1916.2.270 | |||
node · current Extreme 220-Series 48 port 10/100/1000BASE-T, 4 10GbE SFP+ ports (2 LRM Capable), 1 Fixed AC PSU, 1 RPS port, L3 Switching | ||||
| Nextreme220-48p-10GE4 | 1.3.6.1.4.1.1916.2.271 | |||
node · current Extreme 220-Series 48 port 10/100/1000BASE-T PoE+, 4 10GbE unpopulated SFP+ ports (2 LRM Capable), 1 Fixed AC PSU, 1 RPS port, L3 Switching | ||||
| Nextreme240-8mt-16t-10GE4 | 1.3.6.1.4.1.1916.2.272 | |||
node · current 240-Series 8 100/1000/2.5Gb Base-T ports plus 16 ports 10/100/1000BASE-T ports, 4 10GbE unpopulated SFP+ ports, 1 Fixed AC PSU, 1 RPS port | ||||
| Nextreme240-8mp-16p-10GE4 | 1.3.6.1.4.1.1916.2.273 | |||
node · current 240-Series 8 100/1000/2.5Gb Base-T PoE+ ports plus 16 ports 10/100/1000BASE-T PoE+, 4 10GbE unpopulated SFP+ ports, 1 Fixed AC PSU, 1 RPS port | ||||
| Nextreme240-32t-16mt-10GE6 | 1.3.6.1.4.1.1916.2.274 | |||
node · current 240-Series 32 port 10/100/1000Base-T ports plus 16 100/1000/2.5Gb Base-T ports, 6 10GbE unpopulated SFP+ ports (2 LRM capable), 1 Fixed AC PSU, 1 RPS port | ||||
| Nextreme240-32p-16mp-10GE6 | 1.3.6.1.4.1.1916.2.275 | |||
node · current 240-Series 32 port 10/100/1000Base-T PoE+ ports plus 16 100/1000/2.5Gb Base-T PoE+ ports, 6 10GbE unpopulated SFP+ ports (2 LRM capable), 1 Fixed AC PSU, 1 RPS port | ||||
| Nextreme825-48v-6c | 1.3.6.1.4.1.1916.2.276 | |||
node · current X825-48v-6c: 48 10Gb/25Gb SFP28, 6 10Gb/25Gb/40Gb/50Gb/100Gb QSFP28. | ||||
| NextremeNMSxAx25 | 1.3.6.1.4.1.1916.2.277 | |||
node · current Extreme Management Center Server. Management Center is a key component of Extreme's suite of network management products. | ||||
| NextremeNMSxAx305 | 1.3.6.1.4.1.1916.2.278 | |||
node · current Extreme Management Center Server. Management Center is a key component of Extreme's suite of network management products. | ||||
| NextremeIAxAx25 | 1.3.6.1.4.1.1916.2.279 | |||
node · current Extreme Access Control Engine for controlling end system access to the network. It controls network access through Extreme Policy or VLANs based on user, device, OS, location, time, and configuration. Supports optional on-board posture assessment. It is a 1U rack mountable system. | ||||
| NextremeIAxAx305 | 1.3.6.1.4.1.1916.2.280 | |||
node · current Extreme Access Control Engine for controlling end system access to the network. It controls network access through Extreme Policy or VLANs based on user, device, OS, location, time, and configuration. Supports optional on-board posture assessment. It is a 1U rack mountable system. | ||||
| NextremePVxAx305 | 1.3.6.1.4.1.1916.2.281 | |||
node · current Extreme Application Analytics Engine. This appliance provides the engine to monitor and classify layer 7 application information based on data from Extreme switches and report information to ExtremeControl where applications are managed. | ||||
| NextremeEMPx35 | 1.3.6.1.4.1.1916.2.282 | |||
node · current ExtremeCloud IQ Controller E1120 - Premium management platform for the entry-tier on-premise Campus wireless deployment. | ||||
| NextremeEMPx5310 | 1.3.6.1.4.1.1916.2.283 | |||
node · current ExtremeCloud IQ Controller E3120 - Premium management platform for the high-end tier on-premise Campus wireless deployment. | ||||
| NextremeEMPxV | 1.3.6.1.4.1.1916.2.284 | |||
node · current ExtremeCloud IQ Controller VE6120 - Premium management platform for the entry-tier on-premise Campus wireless deployment for VMware ESXi installs. | ||||
| NxtremeWhitebox | 1.3.6.1.4.1.1916.2.286 | |||
| Nvm386EXOS | 1.3.6.1.4.1.1916.2.291 | |||
node · current EXOS i386 platform that can be used in a Virtual Machine environment. | ||||
| NextremeNMSxV | 1.3.6.1.4.1.1916.2.292 | |||
node · current Virtual Extreme Management Center Server. Management Center is a key component of Extreme's suite of network management products. | ||||
| NextremeSSxIxA | 1.3.6.1.4.1.1916.2.293 | |||
node · current Extreme StackStorm Integration Appliance. | ||||
| NextremeESEx2000 | 1.3.6.1.4.1.1916.2.294 | |||
node · current ExtremeCloud IQ Controller E2120 - Premium management platform for the mid-tier on-premise Campus wireless deployment. | ||||
| NextremeFabricManager | 1.3.6.1.4.1.1916.2.295 | |||
node · current Extreme application to manage and orchestrate the SPBm Fabric based network. Fabric Manager will discover and manage the fabric infrastructure as well as L2 / L3 services. | ||||
| Nx590-24t-1q-2c | 1.3.6.1.4.1.1916.2.296 | |||
node · current X590 24 10GBASE-T, 1 10Gb/40Gb QSFP+, 2 10Gb/25Gb/40Gb/50Gb/100Gb QSFP28 | ||||
| Nx590-24x-1q-1c | 1.3.6.1.4.1.1916.2.297 | |||
node · current X590 24 1/10Gb SFP+, 1 10Gb/40Gb QSFP+, 2 10Gb/25Gb/40Gb/50Gb/100Gb QSFP28 | ||||
| NslxOsAcctonAS771232X | 1.3.6.1.4.1.1916.2.298 | |||
node · current Accton AS7712-32X L2/L3 switch with Extreme SLXOS and 32 port 40/100GbE, extendable up to 128 10/25GbE ports. | ||||
| NslxOsDniAG9032v1 | 1.3.6.1.4.1.1916.2.299 | |||
node · current DNI AG9032v1 L2/L3 switch with Extreme SLXOS and 32 port 40/100GbE, extendable up to 128 10/25GbE ports. | ||||
| Nes6108x32c | 1.3.6.1.4.1.1916.2.300 | |||
node · current Extreme Switch 6100 family with 8 cores, 32 QSFP28 100G/40G (channelizable) ports and 2 10G Sideband ports. | ||||
| Nes6108x48vx8c | 1.3.6.1.4.1.1916.2.301 | |||
node · current Extreme Switch 6100 family with 8 cores, 48 SFP28 25G ports and 8 100G/40G (Channelizeable) and 2 10G Sideband ports. | ||||
| Nvsp7432CQ | 1.3.6.1.4.1.1916.2.302 | |||
node · current Virtual Services Platform 7400 family with 8 cores, 32 QSFP28 100G/40G (Channelizable) ports and 2 10G Internal ports. | ||||
| Nvsp7456VSC | 1.3.6.1.4.1.1916.2.303 | |||
node · current Virtual Services Platform 7400 family with 8 cores, 48 SFP28 25G ports and 8 100G/40G (Channelizable) and 1 10G Internal ports. | ||||
| NextremeSLX9030 | 1.3.6.1.4.1.1916.2.304 | |||
node · current Extreme L2/L3 Switch with SLXOS and 48x10GE/1GE + 4x100GE/40GE interfaces. | ||||
| NextremeSLX9030T | 1.3.6.1.4.1.1916.2.305 | |||
node · current Extreme L2/L3 Switch with SLXOS and 48x10GE/1GE/100M Base-T + 4x100GE/40GE interfaces. | ||||
| NextremeSLX9640 | 1.3.6.1.4.1.1916.2.306 | |||
node · current Extreme L2/L3 Switch/Router with SLXOS and 24xSFP+ (1GE/10GE) + 12xQSFP28 (40GE/4x10GE/100GE/4x25GE/2x50GE) interfaces. | ||||
| Nvsp1100 | 1.3.6.1.4.1.1916.2.307 | |||
node · current Virtual Services Platform 1100 family to run as a service in a VM on a Hypervisor with all the VOSS features supported on any standard x86 hardware. | ||||
| NextremeCspAwsSubnetType | 1.3.6.1.4.1.1916.2.308 | |||
node · current Extreme Cloud Services Platform virtual switch for Amazon Web Services (AWS) Subnet Type deployments. | ||||
| NextremeCspGcpSubnetType | 1.3.6.1.4.1.1916.2.309 | |||
node · current Extreme Cloud Services Platform virtual switch for Google Cloud Platform (GCP) Subnet Type deployments. | ||||
| NextremeCspAzureSubnetType | 1.3.6.1.4.1.1916.2.310 | |||
node · current Extreme Cloud Services Platform virtual switch for Azure Subnet Type deployments. | ||||
| NextremeMcsVmwareHypervisorType | 1.3.6.1.4.1.1916.2.311 | |||
node · current Extreme Management Connect Services virtual switch for physical VMware Hypervisor deployments. | ||||
| Nx465-48t | 1.3.6.1.4.1.1916.2.312 | |||
node · current X465 with 48 10/100/1000Mb FDX/HDX MACSEC capable ports, 1 VIM slot | ||||
| Nx465-48p | 1.3.6.1.4.1.1916.2.313 | |||
node · current X465 with 48 10/100/1000Mb FDX/HDX MACSEC capable ports, 802.3at PoE (30W), 1 VIM slot | ||||
| Nx465-48w | 1.3.6.1.4.1.1916.2.314 | |||
node · current X465 with 48 10/100/1000Mb FDX/HDX MACSEC capable ports, 802.3bt Type3/Type4 PoE (90W), 1 VIM slot | ||||
| Nx465-24mu | 1.3.6.1.4.1.1916.2.315 | |||
node · current X465 with 24 100Mb/1/2.5/5Gb ports, 802.3bt Type3 PoE (60W), 1 VIM slot | ||||
| Nx465-24mu-24w | 1.3.6.1.4.1.1916.2.316 | |||
node · current X465 with 24 100Mb/1/2.5/5Gb ports, 802.3bt Type3 PoE (60W) and 24 10/100/1000Mb FDX/HDX ports with MACSEC, 802.1bt Type3/Type4 PoE (90W), 1 VIM slot | ||||
| Nx465-24w | 1.3.6.1.4.1.1916.2.319 | |||
node · current X465 with 24 10/100/1000Mb FDX/HDX MACSEC capable ports, 802.3bt PoE Type3/Type4 (90W), 1 VIM slot | ||||
| Nx725-48y-8c | 1.3.6.1.4.1.1916.2.320 | |||
node · current X725 with 48 10Gb/25Gb SFP28 ports and 8 10Gb/25Gb/40Gb/50Gb/100Gb QSFP28 ports | ||||
| NextremeSnVirtualSensor100 | 1.3.6.1.4.1.1916.2.321 | |||
node · current Extreme Analytics Virtual Sensor Model 100. | ||||
| NextremeSnVirtualSensor250 | 1.3.6.1.4.1.1916.2.322 | |||
node · current Extreme Analytics Virtual Sensor Model 250. | ||||
| Nvsp4900x24P | 1.3.6.1.4.1.1916.2.323 | |||
node · current Virtual Services Platform 4900 family with 2 cores, 24 10/100/1000/10000 Mbps copper ports and VIM support | ||||
| Nvsp4900x48P | 1.3.6.1.4.1.1916.2.324 | |||
node · current Virtual Services Platform 4900 family with 2 cores, 48 10/100/1000/10000 Mbps copper ports and VIM support | ||||
| Nvsp7400-48Y-8C | 1.3.6.1.4.1.1916.2.325 | |||
node · current Virtual Services Platform 7400 family with 8 cores, 48 SFP28 25G ports and 8 100G/40G (Channelizable) and 1 10G Internal ports. | ||||
| NextremeVirtualTAP | 1.3.6.1.4.1.1916.2.326 | |||
node · current Extreme Virtual TAP (vTAP) is a full-featured network visibility solution software based tap built for virtualized service provider and enterprise networks. It offers an end-to-end set of capabilities including traffic interception, filtering (SMARTMatch), header stripping, packet slicing, sampling and IPFIX export, and optimization for network monitoring and analytics tools. | ||||
| NextremeVirtualPB | 1.3.6.1.4.1.1916.2.327 | |||
node · current Extreme Virtual Packet Broker(vPB) is an aggregator of Extreme Virtual Taps(vTAP). | ||||
| Nx695-48y-8c | 1.3.6.1.4.1.1916.2.328 | |||
node · current X695 with 48 1Gb/10Gb/25Gb SFP28 and 8 40Gb/100Gb QSFP28 | ||||
| NextremeOnieStack | 1.3.6.1.4.1.1916.2.329 | |||
node · current A stacked version of EXOS ONIE-based switches | ||||
| Nx465-24xe | 1.3.6.1.4.1.1916.2.330 | |||
node · current X465 with 24 1/10GbE SFP+ MACSEC capable ports, 1 VIM slot | ||||
| Nx465-24s | 1.3.6.1.4.1.1916.2.331 | |||
node · current X465-24s: X465 with 24 1GbE SFP ports, 1 VIM slot | ||||
| NextremeSLX9150 | 1.3.6.1.4.1.1916.2.332 | |||
node · current Extreme L2/L3 Switch with SLXOS, 48x25GE/10GE and 8x100GE/40GE interfaces. | ||||
| NextremeSLX9150T | 1.3.6.1.4.1.1916.2.333 | |||
node · current Extreme L2/L3 Switch with SLXOS, 48x10GE/1GE Base-T and 6x100GE/40GE interfaces. | ||||
| NextremeSLX9250 | 1.3.6.1.4.1.1916.2.334 | |||
node · current Extreme L2/L3 Switch with SLXOS and 32x100GE/40GE interfaces. | ||||
| NextremeSLX9740x40 | 1.3.6.1.4.1.1916.2.335 | |||
node · current Extreme L2/L3 Switch/Router with SLXOS and 40x100GE/40GE interfaces. | ||||
| NextremeSLX9740x80 | 1.3.6.1.4.1.1916.2.336 | |||
node · current Extreme L2/L3 Switch/Router with SLXOS and 80x100GE/40GE interfaces. | ||||
| Nxa1440 | 1.3.6.1.4.1.1916.2.337 | |||
node · current Extreme Access Platform running VOSS software as a VM on Hypervisor over 4 cores Denverton base box | ||||
| Nxa1480 | 1.3.6.1.4.1.1916.2.338 | |||
node · current Extreme Access Platform running VOSS software as a VM on Hypervisor over 8 cores Denverton base box | ||||
| NextremeECAx6125 | 1.3.6.1.4.1.1916.2.339 | |||
node · current ExtremeCloud IQ Controller VE6125 - Premium management platform for the mid-tier on-premise Campus wireless deployment for VMware ESXi installs. | ||||
| Nvsp4900x24XE | 1.3.6.1.4.1.1916.2.340 | |||
node · current Virtual Services Platform 4900 family with Quad cores, 24x10GbE (SFP+) with MACSec Fiber ports and VIM support | ||||
| Nvsp4900x12MXU12XE | 1.3.6.1.4.1.1916.2.341 | |||
node · current Virtual Services Platform 4900 family with Quad cores, 12 x 100/1G/2.5G/5G/10G (60W PoE) + 12 x 10G (SFP+) with MACsec Fiber ports and VIM support | ||||
| Nvsp4900x24S | 1.3.6.1.4.1.1916.2.342 | |||
node · current Virtual Services Platform 4900 family with Quad cores, 24 x 1G (SFP) Fiber ports and VIM support | ||||
| Nx435-24p-4s | 1.3.6.1.4.1.1916.2.343 | |||
node · current X435 with 24 10/100/1000Mb FDX/HDX capable ports, 802.3at PoE (30W), 2 1/2.5G SFP ports | ||||
| Nx435-24t-4s | 1.3.6.1.4.1.1916.2.344 | |||
node · current X435 with 24 10/100/1000Mb FDX/HDX capable ports, 2 1/2.5G SFP ports | ||||
| Nx435-8p-4s | 1.3.6.1.4.1.1916.2.345 | |||
node · current X435 with 8 10/100/1000Mb FDX/HDX capable ports, 802.3at PoE (30W), 2 1/2.5G SFP ports | ||||
| Nx435-8t-4s | 1.3.6.1.4.1.1916.2.346 | |||
node · current X435 with 8 10/100/1000Mb FDX/HDX capable ports, 2 1/2.5G SFP ports | ||||
| Nx435-8p-2t-w | 1.3.6.1.4.1.1916.2.347 | |||
node · current X435 with 8 10/100/1000Mb FDX/HDX capable ports, 802.3at PoE (30W), 2 10/100/1000Mb FDX/HDX, 802.3bt PoE (90W) powered ports | ||||
| Nx465i-48w | 1.3.6.1.4.1.1916.2.348 | |||
node · current X465 with 48 10/100/1000Mb FDX/HDX MACSEC capable ports, 802.3bt Type3/Type4 PoE (90W), 1 VIM slot | ||||
| Nextreme552024TEXOS | 1.3.6.1.4.1.1916.2.349 | |||
node · current ExtremeSwitching 5520-24T (EXOS) with 24 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024WEXOS | 1.3.6.1.4.1.1916.2.350 | |||
node · current ExtremeSwitching 5520-24W (EXOS) with 24 10/100/1000BASE-T FDX/HDX 802.3bt Type4 PoE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048TEXOS | 1.3.6.1.4.1.1916.2.351 | |||
node · current ExtremeSwitching 5520-48T (EXOS) with 48 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048WEXOS | 1.3.6.1.4.1.1916.2.352 | |||
node · current ExtremeSwitching 5520-48W (EXOS) with 48 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552012MW36WEXOS | 1.3.6.1.4.1.1916.2.353 | |||
node · current ExtremeSwitching 5520-12MW-36W (EXOS) with 12 1000Mb/1Gb/2.5Gb/5Gb 802.3bt Type4 POE (90W) MACsec capable ports and 36 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048SEEXOS | 1.3.6.1.4.1.1916.2.354 | |||
node · current ExtremeSwitching 5520-48SE (EXOS) with 48 100/1000BASE-X MACsec capable SFP ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024XEXOS | 1.3.6.1.4.1.1916.2.355 | |||
node · current ExtremeSwitching 5520-24X (EXOS) with 24 100/1000BASE-X unpopulated SFP ports upgradeable to 10Gb SFP+, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| NextremeECAx6120H | 1.3.6.1.4.1.1916.2.356 | |||
node · current ExtremeCloud IQ Controller VE6120H - Premium management platform for the entry-tier on-premise Campus wireless deployment for Microsoft Hyper-V installs. | ||||
| NextremeECAx6125H | 1.3.6.1.4.1.1916.2.357 | |||
node · current Extreme Campus Controller. The VE6125H is an elastic virtual appliance for Microsoft Hyper-V that supports up to 2,000 APs/Defenders, up to 200 switches and 16,000 mobility sessions depending on the hosting hardware. | ||||
| Nextreme552024TVOSS | 1.3.6.1.4.1.1916.2.358 | |||
node · current ExtremeSwitching 5520-24T (VOSS) with 24 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024WVOSS | 1.3.6.1.4.1.1916.2.359 | |||
node · current ExtremeSwitching 5520-24W (VOSS) with 24 10/100/1000BASE-T FDX/HDX 802.3bt Type4 PoE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048TVOSS | 1.3.6.1.4.1.1916.2.360 | |||
node · current ExtremeSwitching 5520-48T (VOSS) with 48 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048WVOSS | 1.3.6.1.4.1.1916.2.361 | |||
node · current ExtremeSwitching 5520-48W (VOSS) with 48 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552012MW36WVOSS | 1.3.6.1.4.1.1916.2.362 | |||
node · current ExtremeSwitching 5520-12MW-36W (VOSS) with 12 1000Mb/1Gb/2.5Gb/5Gb 802.3bt Type4 POE (90W) MACsec capable ports and 36 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048SEVOSS | 1.3.6.1.4.1.1916.2.363 | |||
node · current ExtremeSwitching 5520-48SE (VOSS) with 48 100/1000BASE-X MACsec capable SFP ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024XVOSS | 1.3.6.1.4.1.1916.2.364 | |||
node · current ExtremeSwitching 5520-24X (VOSS) with 24 100/1000BASE-X/10GBASE-X SFP+, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme5420F24P4XEEXOS | 1.3.6.1.4.1.1916.2.365 | |||
node · current ExtremeSwitching 5420F (EXOS) with 24 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F8W16P4XEEXOS | 1.3.6.1.4.1.1916.2.366 | |||
node · current ExtremeSwitching 5420F (EXOS) with 8 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex ports, 16 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F24T4XEEXOS | 1.3.6.1.4.1.1916.2.367 | |||
node · current ExtremeSwitching 5420F (EXOS) with 24 10/100/1000 BASE-T w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F48P4XEEXOS | 1.3.6.1.4.1.1916.2.368 | |||
node · current ExtremeSwitching 5420F (EXOS) with 48 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F16W32P4XEEXOS | 1.3.6.1.4.1.1916.2.369 | |||
node · current ExtremeSwitching 5420F (EXOS) with 16 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex ports, 32 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F48T4XEEXOS | 1.3.6.1.4.1.1916.2.370 | |||
node · current ExtremeSwitching 5420F (EXOS) with 48 10/100/1000 BASE-T w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F16MW32P4XEEXOS | 1.3.6.1.4.1.1916.2.371 | |||
node · current ExtremeSwitching 5420F (EXOS) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W) ports, 32 10/100/1000 BASE-T w/ Half Duplex PoE ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F24S4XEEXOS | 1.3.6.1.4.1.1916.2.372 | |||
node · current ExtremeSwitching 5420F (EXOS) with 24 100/1G unpopulated SFP ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F48P4XLEXOS | 1.3.6.1.4.1.1916.2.373 | |||
node · current ExtremeSwitching 5420F (EXOS) with 48 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ with LRM ports | ||||
| Nextreme5420M24W4YEEXOS | 1.3.6.1.4.1.1916.2.374 | |||
node · current ExtremeSwitching 5420M (EXOS) with 24 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M24T4YEEXOS | 1.3.6.1.4.1.1916.2.375 | |||
node · current ExtremeSwitching 5420M (EXOS) with 24 10/100/1000 BASE-T w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M48W4YEEXOS | 1.3.6.1.4.1.1916.2.376 | |||
node · current ExtremeSwitching 5420M (EXOS) with 48 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M48T4YEEXOS | 1.3.6.1.4.1.1916.2.377 | |||
node · current ExtremeSwitching 5420M (EXOS) with 48 10/100/1000 BASE-T w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M16MW32P4YEEXOS | 1.3.6.1.4.1.1916.2.378 | |||
node · current ExtremeSwitching 5420M (EXOS) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W) ports, 32 10/100/1000 BASE-T w/ Half Duplex PoE ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| NextremeXCAxQ4120 | 1.3.6.1.4.1.1916.2.379 | |||
node · current Extreme Universal Compute Platform 4120C Appliance - Software distribution and orchestration platform for network edge computing. | ||||
| NextremeXCAxVQ6120 | 1.3.6.1.4.1.1916.2.380 | |||
node · current Extreme Universal Compute Platform 4020V Appliance - Software distribution and orchestration platform for network edge computing. | ||||
| NextremeXCCx2122 | 1.3.6.1.4.1.1916.2.381 | |||
node · current ExtremeCloud IQ Controller E2122 - Premium management platform for the mid-tier on-premise Campus wireless deployment. | ||||
| NextremeXCCx6120K | 1.3.6.1.4.1.1916.2.382 | |||
node · current ExtremeCloud IQ Controller VE6120K - Premium management platform for the entry-tier on-premise Campus wireless deployment for Linux KVM installs. | ||||
| NextremeXCCx6125K | 1.3.6.1.4.1.1916.2.383 | |||
node · current ExtremeCloud IQ Controller VE6125K - Premium management platform for the mid-tier on-premise Campus wireless deployment for Linux KVM installs. | ||||
| NextremeArmStack | 1.3.6.1.4.1.1916.2.384 | |||
node · current A stacked version of EXOS ARM-based switches | ||||
| Nextreme572024MWSwitchEngine | 1.3.6.1.4.1.1916.2.385 | |||
node · current ExtremeSwitching 5720-24MW (Switch Engine) with 24 100Mb/1Gb/2.5Gb/5Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| Nextreme572048MWSwitchEngine | 1.3.6.1.4.1.1916.2.386 | |||
node · current ExtremeSwitching 5720-48MW (Switch Engine) with 48 100Mb/1Gb/2.5Gb/5Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| Nextreme572024MXWSwitchEngine | 1.3.6.1.4.1.1916.2.387 | |||
node · current ExtremeSwitching 5720-24MXW (Switch Engine) with 24 100Mb/1Gb/2.5Gb/5Gb/10Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| Nextreme572048MXWSwitchEngine | 1.3.6.1.4.1.1916.2.388 | |||
node · current ExtremeSwitching 5720-48MXW (Switch Engine) with 48 100Mb/1Gb/2.5Gb/5Gb/10Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| Nextreme572024MWFabricEngine | 1.3.6.1.4.1.1916.2.389 | |||
node · current ExtremeSwitching 5720-24MW (Fabric Engine) with 24 100Mb/1Gb/2.5Gb/5Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| Nextreme572048MWFabricEngine | 1.3.6.1.4.1.1916.2.390 | |||
node · current ExtremeSwitching 5720-48MW (Fabric Engine) with 48 100Mb/1Gb/2.5Gb/5Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| Nextreme572024MXWFabricEngine | 1.3.6.1.4.1.1916.2.391 | |||
node · current ExtremeSwitching 5720-24MXW (Fabric Engine) with 24 100Mb/1Gb/2.5Gb/5Gb/10Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| Nextreme572048MXWFabricEngine | 1.3.6.1.4.1.1916.2.392 | |||
node · current ExtremeSwitching 5720-48MXW (Fabric Engine) with 48 100Mb/1Gb/2.5Gb/5Gb/10Gb 802.3bt 90W PoE, 2 stacking/QSFP28, 1 unpopulated VIM slot, MACsec capable, includes fan modules, 2 unpopulated modular PSU slots | ||||
| NextremeSwitchEngineMixedStack | 1.3.6.1.4.1.1916.2.393 | |||
node · current A stacked version of Switch Engine ONIE and ARM-based switches | ||||
| Nextreme752048Y8CSwitchEngine | 1.3.6.1.4.1.1916.2.394 | |||
node · current 7520-48Y-8C (Switch Engine) with 48 1Gb/10Gb/25Gb SFP28, 8 40Gb/100Gb QSFP28, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme752048XT6CSwitchEngine | 1.3.6.1.4.1.1916.2.395 | |||
node · current 7520-48XT-6C (Switch Engine) with 48 1Gb/10Gb 10GBASE-T, 6 40Gb/100Gb QSFP28, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme5420F24P4XEVOSS | 1.3.6.1.4.1.1916.2.396 | |||
node · current 5420F (VOSS) with 24 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F8W16P4XEVOSS | 1.3.6.1.4.1.1916.2.397 | |||
node · current 5420F (VOSS) with 8 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex, 16 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F24T4XEVOSS | 1.3.6.1.4.1.1916.2.398 | |||
node · current 5420F (VOSS) with 24 10/100/1000 BASE-T w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F48P4XEVOSS | 1.3.6.1.4.1.1916.2.399 | |||
node · current 5420F (VOSS) with 48 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F16W32P4XEVOSS | 1.3.6.1.4.1.1916.2.400 | |||
node · current 5420F (VOSS) with 16 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex, 32 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F48T4XEVOSS | 1.3.6.1.4.1.1916.2.401 | |||
node · current 5420F (VOSS) with 48 10/100/1000 BASE-T w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F16MW32P4XEVOSS | 1.3.6.1.4.1.1916.2.402 | |||
node · current 5420F (VOSS) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W), 32 10/100/1000 BASE-T w/ Half Duplex PoE, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F24S4XEVOSS | 1.3.6.1.4.1.1916.2.403 | |||
node · current 5420F (VOSS) with 24 100/1G unpopulated SFP, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F48P4XLVOSS | 1.3.6.1.4.1.1916.2.404 | |||
node · current 5420F (VOSS) with 48 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ with LRM | ||||
| Nextreme5420M24W4YEVOSS | 1.3.6.1.4.1.1916.2.405 | |||
node · current 5420M (VOSS) with 24 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M24T4YEVOSS | 1.3.6.1.4.1.1916.2.406 | |||
node · current 5420M (VOSS) with 24 10/100/1000 BASE-T w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M48W4YEVOSS | 1.3.6.1.4.1.1916.2.407 | |||
node · current 5420M (VOSS) with 48 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M48T4YEVOSS | 1.3.6.1.4.1.1916.2.408 | |||
node · current 5420M (VOSS) with 48 10/100/1000 BASE-T w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M16MW32P4YEVOSS | 1.3.6.1.4.1.1916.2.409 | |||
node · current 5420M (VOSS) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W), 32 10/100/1000 BASE-T w/ Half Duplex PoE, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| NextremeNPB9920 | 1.3.6.1.4.1.1916.2.410 | |||
node · current Network Packet Broker NPB9920. | ||||
| Nextreme532024P8XEEXOS | 1.3.6.1.4.1.1916.2.411 | |||
node · current ExtremeSwitching 5320 (EXOS) 24 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532024T8XEEXOS | 1.3.6.1.4.1.1916.2.412 | |||
node · current ExtremeSwitching 5320 (EXOS) 24 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048P8XEEXOS | 1.3.6.1.4.1.1916.2.413 | |||
node · current ExtremeSwitching 5320 (EXOS) 48 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048T8XEEXOS | 1.3.6.1.4.1.1916.2.414 | |||
node · current ExtremeSwitching 5320 (EXOS) 48 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XEEXOS | 1.3.6.1.4.1.1916.2.415 | |||
node · current ExtremeSwitching 5320 (EXOS) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XEDCEXOS | 1.3.6.1.4.1.1916.2.416 | |||
node · current ExtremeSwitching 5320 (EXOS) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed DC PSU, fans | ||||
| NextremeNMSxGeneric | 1.3.6.1.4.1.1916.2.417 | |||
node · current Extreme Management Center Server. Management Center is a key component of Extreme's suite of network management products. | ||||
| NextremeIAxGeneric | 1.3.6.1.4.1.1916.2.418 | |||
node · current Extreme Access Control Engine for controlling end system access to the network. It controls network access through Extreme Policy or VLANs based on user, device, OS, location, time, and configuration. Supports optional on-board posture assessment. It is a 1U rack mountable system. | ||||
| NextremePVxGeneric | 1.3.6.1.4.1.1916.2.419 | |||
node · current Extreme Application Analytics Engine. This appliance provides the engine to monitor and classify layer 7 application information based on data from Extreme switches and report information to ExtremeControl where applications are managed. | ||||
| NextremeAnalyticsApplianceV | 1.3.6.1.4.1.1916.2.420 | |||
node · current Extreme Virtual Application Sensor and Analytics Engine. This appliance provides the engine to monitor and classify layer 7 application information based on data from Extreme switches and report information to ExtremeControl where applications are managed. | ||||
| Nextreme532024P8XEVOSS | 1.3.6.1.4.1.1916.2.421 | |||
node · current ExtremeSwitching 5320 (VOSS) 24 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532024T8XEVOSS | 1.3.6.1.4.1.1916.2.422 | |||
node · current ExtremeSwitching 5320 (VOSS) 24 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048P8XEVOSS | 1.3.6.1.4.1.1916.2.423 | |||
node · current ExtremeSwitching 5320 (VOSS) 48 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048T8XEVOSS | 1.3.6.1.4.1.1916.2.424 | |||
node · current ExtremeSwitching 5320 (VOSS) 48 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XEVOSS | 1.3.6.1.4.1.1916.2.425 | |||
node · current ExtremeSwitching 5320 (VOSS) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XEDCVOSS | 1.3.6.1.4.1.1916.2.426 | |||
node · current ExtremeSwitching 5320 (VOSS) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed DC PSU, fans | ||||
| Nvm386EXOSStack | 1.3.6.1.4.1.1916.2.427 | |||
node · current EXOS i386 platform that can be used in a Virtual Machine environment to simulate stacking. | ||||
| NextremeAnalyticsAppliance | 1.3.6.1.4.1.1916.2.428 | |||
node · current Extreme Application Sensor and Analytics Engine. This appliance provides the engine to monitor and classify layer 7 application information based on data from Extreme switches and report information to ExtremeControl where applications are managed. | ||||
| NextremeXCCxCE3000 | 1.3.6.1.4.1.1916.2.429 | |||
node · current ExtremeCloud IQ Controller CE3000 - Premium management platform for the high-tier on-premise Campus wireless deployment for UCP Large Scale Platform installs. | ||||
| Nextreme552024TSwitchEngine | 1.3.6.1.4.1.1916.2.430 | |||
node · current ExtremeSwitching 5520-24T (Switch Engine) with 24 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024WSwitchEngine | 1.3.6.1.4.1.1916.2.431 | |||
node · current ExtremeSwitching 5520-24W (Switch Engine) with 24 10/100/1000BASE-T FDX/HDX 802.3bt Type4 PoE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048TSwitchEngine | 1.3.6.1.4.1.1916.2.432 | |||
node · current ExtremeSwitching 5520-48T (Switch Engine) with 48 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048WSwitchEngine | 1.3.6.1.4.1.1916.2.433 | |||
node · current ExtremeSwitching 5520-48W (Switch Engine) with 48 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552012MW36WSwitchEngine | 1.3.6.1.4.1.1916.2.434 | |||
node · current ExtremeSwitching 5520-12MW-36W (Switch Engine) with 12 1000Mb/1Gb/2.5Gb/5Gb 802.3bt Type4 POE (90W) MACsec capable ports and 36 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048SESwitchEngine | 1.3.6.1.4.1.1916.2.435 | |||
node · current ExtremeSwitching 5520-48SE (Switch Engine) with 48 100/1000BASE-X MACsec capable SFP ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024XSwitchEngine | 1.3.6.1.4.1.1916.2.436 | |||
node · current ExtremeSwitching 5520-24X (Switch Engine) with 24 100/1000BASE-X unpopulated SFP ports upgradeable to 10Gb SFP+, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024TFabricEngine | 1.3.6.1.4.1.1916.2.437 | |||
node · current ExtremeSwitching 5520-24T (Fabric Engine) with 24 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024WFabricEngine | 1.3.6.1.4.1.1916.2.438 | |||
node · current ExtremeSwitching 5520-24W (Fabric Engine) with 24 10/100/1000BASE-T FDX/HDX 802.3bt Type4 PoE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048TFabricEngine | 1.3.6.1.4.1.1916.2.439 | |||
node · current ExtremeSwitching 5520-48T (Fabric Engine) with 48 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048WFabricEngine | 1.3.6.1.4.1.1916.2.440 | |||
node · current ExtremeSwitching 5520-48W (Fabric Engine) with 48 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552012MW36WFabricEngine | 1.3.6.1.4.1.1916.2.441 | |||
node · current ExtremeSwitching 5520-12MW-36W (Fabric Engine) with 12 1000Mb/1Gb/2.5Gb/5Gb 802.3bt Type4 POE (90W) MACsec capable ports and 36 10/100/1000BASE-T FDX/HDX 802.3bt Type4 POE (90W) MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552048SEFabricEngine | 1.3.6.1.4.1.1916.2.442 | |||
node · current ExtremeSwitching 5520-48SE (Fabric Engine) with 48 100/1000BASE-X MACsec capable SFP ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme552024XFabricEngine | 1.3.6.1.4.1.1916.2.443 | |||
node · current ExtremeSwitching 5520-24X (Fabric Engine) with 24 100/1000BASE-X/10GBASE-X SFP+, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot. | ||||
| Nextreme5420F24P4XESwitchEngine | 1.3.6.1.4.1.1916.2.444 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 24 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F8W16P4XESwitchEngine | 1.3.6.1.4.1.1916.2.445 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 8 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex ports, 16 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F24T4XESwitchEngine | 1.3.6.1.4.1.1916.2.446 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 24 10/100/1000 BASE-T w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F48P4XESwitchEngine | 1.3.6.1.4.1.1916.2.447 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 48 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F16W32P4XESwitchEngine | 1.3.6.1.4.1.1916.2.448 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 16 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex ports, 32 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F48T4XESwitchEngine | 1.3.6.1.4.1.1916.2.449 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 48 10/100/1000 BASE-T w/ Half Duplex ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F16MW32P4XESwitchEngine | 1.3.6.1.4.1.1916.2.450 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W) ports, 32 10/100/1000 BASE-T w/ Half Duplex PoE ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F24S4XESwitchEngine | 1.3.6.1.4.1.1916.2.451 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 24 100/1G unpopulated SFP ports, 4 10G unpopulated SFP+ ports | ||||
| Nextreme5420F48P4XLSwitchEngine | 1.3.6.1.4.1.1916.2.452 | |||
node · current ExtremeSwitching 5420F (Switch Engine) with 48 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10G unpopulated SFP+ with LRM ports | ||||
| Nextreme5420M24W4YESwitchEngine | 1.3.6.1.4.1.1916.2.453 | |||
node · current ExtremeSwitching 5420M (Switch Engine) with 24 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M24T4YESwitchEngine | 1.3.6.1.4.1.1916.2.454 | |||
node · current ExtremeSwitching 5420M (Switch Engine) with 24 10/100/1000 BASE-T w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M48W4YESwitchEngine | 1.3.6.1.4.1.1916.2.455 | |||
node · current ExtremeSwitching 5420M (Switch Engine) with 48 10/100/1000 BASE-T PoE w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M48T4YESwitchEngine | 1.3.6.1.4.1.1916.2.456 | |||
node · current ExtremeSwitching 5420M (Switch Engine) with 48 10/100/1000 BASE-T w/ Half Duplex ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420M16MW32P4YESwitchEngine | 1.3.6.1.4.1.1916.2.457 | |||
node · current ExtremeSwitching 5420M (Switch Engine) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W) ports, 32 10/100/1000 BASE-T w/ Half Duplex PoE ports, 4 10/25G unpopulated SFP28 ports (w/ modular PSU/Fan) | ||||
| Nextreme5420F24P4XEFabricEngine | 1.3.6.1.4.1.1916.2.458 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 24 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F8W16P4XEFabricEngine | 1.3.6.1.4.1.1916.2.459 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 8 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex, 16 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F24T4XEFabricEngine | 1.3.6.1.4.1.1916.2.460 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 24 10/100/1000 BASE-T w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F48P4XEFabricEngine | 1.3.6.1.4.1.1916.2.461 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 48 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F16W32P4XEFabricEngine | 1.3.6.1.4.1.1916.2.462 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 16 10/100/1000 BASE-T Type4 PoE (90W) w/ Half Duplex, 32 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F48T4XEFabricEngine | 1.3.6.1.4.1.1916.2.463 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 48 10/100/1000 BASE-T w/ Half Duplex, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F16MW32P4XEFabricEngine | 1.3.6.1.4.1.1916.2.464 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W), 32 10/100/1000 BASE-T w/ Half Duplex PoE, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F24S4XEFabricEngine | 1.3.6.1.4.1.1916.2.465 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 24 100/1G unpopulated SFP, 4 10G unpopulated SFP+ | ||||
| Nextreme5420F48P4XLFabricEngine | 1.3.6.1.4.1.1916.2.466 | |||
node · current ExtremeSwitching 5420F (Fabric Engine) with 48 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10G unpopulated SFP+ with LRM | ||||
| Nextreme5420M24W4YEFabricEngine | 1.3.6.1.4.1.1916.2.467 | |||
node · current ExtremeSwitching 5420M (Fabric Engine) with 24 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M24T4YEFabricEngine | 1.3.6.1.4.1.1916.2.468 | |||
node · current ExtremeSwitching 5420M (Fabric Engine) with 24 10/100/1000 BASE-T w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M48W4YEFabricEngine | 1.3.6.1.4.1.1916.2.469 | |||
node · current ExtremeSwitching 5420M (Fabric Engine) with 48 10/100/1000 BASE-T PoE w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M48T4YEFabricEngine | 1.3.6.1.4.1.1916.2.470 | |||
node · current ExtremeSwitching 5420M (Fabric Engine) with 48 10/100/1000 BASE-T w/ Half Duplex, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| Nextreme5420M16MW32P4YEFabricEngine | 1.3.6.1.4.1.1916.2.471 | |||
node · current ExtremeSwitching 5420M (Fabric Engine) with 16 100/1G/2.5G Multi-Rate 802.3bt Type4 PoE (90W), 32 10/100/1000 BASE-T w/ Half Duplex PoE, 4 10/25G unpopulated SFP28 (w/ modular PSU/Fan) | ||||
| NextremeSwitchEngineARMStack | 1.3.6.1.4.1.1916.2.472 | |||
node · current A stacked version of Switch Engine ARM-based switches | ||||
| Nextreme752048Y8CFabricEngine | 1.3.6.1.4.1.1916.2.473 | |||
node · current 7520-48Y-8C (Fabric Engine) with 48 1Gb/10Gb/25Gb SFP28, 8 40Gb/100Gb QSFP28, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme752048XT6CFabricEngine | 1.3.6.1.4.1.1916.2.474 | |||
node · current 7520-48XT-6C (Fabric Engine) with 48 1Gb/10Gb 10GBASE-T, 6 40Gb/100Gb QSFP28, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme772032CSwitchEngine | 1.3.6.1.4.1.1916.2.475 | |||
node · current 7720-32C (Switch Engine) with 32 40Gb/100Gb QSFP28, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme772032CFabricEngine | 1.3.6.1.4.1.1916.2.476 | |||
node · current 7720-32C (Fabric Engine) with 32 40Gb/100Gb QSFP28, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme532024P8XESwitchEngine | 1.3.6.1.4.1.1916.2.477 | |||
node · current ExtremeSwitching 5320 (Switch Engine) 24 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532024T8XESwitchEngine | 1.3.6.1.4.1.1916.2.478 | |||
node · current ExtremeSwitching 5320 (Switch Engine) 24 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048P8XESwitchEngine | 1.3.6.1.4.1.1916.2.479 | |||
node · current ExtremeSwitching 5320 (Switch Engine) 48 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048T8XESwitchEngine | 1.3.6.1.4.1.1916.2.480 | |||
node · current ExtremeSwitching 5320 (Switch Engine) 48 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XESwitchEngine | 1.3.6.1.4.1.1916.2.481 | |||
node · current ExtremeSwitching 5320 (Switch Engine) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XEDCSwitchEngine | 1.3.6.1.4.1.1916.2.482 | |||
node · current ExtremeSwitching 5320 (Switch Engine) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed DC PSU, fans | ||||
| Nextreme532024P8XEFabricEngine | 1.3.6.1.4.1.1916.2.483 | |||
node · current ExtremeSwitching 5320 (Fabric Engine) 24 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532024T8XEFabricEngine | 1.3.6.1.4.1.1916.2.484 | |||
node · current ExtremeSwitching 5320 (Fabric Engine) 24 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048P8XEFabricEngine | 1.3.6.1.4.1.1916.2.485 | |||
node · current ExtremeSwitching 5320 (Fabric Engine) 48 10/100/1000BASET FDX/HDX PoE+, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532048T8XEFabricEngine | 1.3.6.1.4.1.1916.2.486 | |||
node · current ExtremeSwitching 5320 (Fabric Engine) 48 10/100/1000BASET FDX/HDX, 8 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XEFabricEngine | 1.3.6.1.4.1.1916.2.487 | |||
node · current ExtremeSwitching 5320 (Fabric Engine) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed PSU, fans | ||||
| Nextreme532016P4XEDCFabricEngine | 1.3.6.1.4.1.1916.2.488 | |||
node · current ExtremeSwitching 5320 (Fabric Engine) 16 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, MACSec capable, internal fixed DC PSU, fans | ||||
| NextremeISW4W4WS4X | 1.3.6.1.4.1.1916.2.489 | |||
node · current 12-Port ISW Industrial Ethernet Switch 4 10/100/1000BASE-T 90W PoE ports, 4 combo ports supporting either 4 10/100/1000BASE-T 90W PoE OR 4 1000BASE-X (SFP), plus 4 10GBASE-X SFP+ ports, Oper Temp -40C - +75C, dual DC power inputs, fanless | ||||
| NextremeISW24W4X | 1.3.6.1.4.1.1916.2.490 | |||
node · current 28-Port ISW Industrial Ethernet Switch 24 10/100/1000BASE-T 90W PoE ports, plus 4 10GBASE-X SFP+ ports, 720W PoE, Operating Temp -40C - +75C, dual DC power inputs, fanless, 1RU | ||||
| NextremeSwitchEngineOnieStack | 1.3.6.1.4.1.1916.2.491 | |||
node · current A stacked version of Switch Engine ONIE-based switches | ||||
| Nextreme422012T4XSwitchEngine | 1.3.6.1.4.1.1916.2.492 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 12 10/100/1000BASET FDX/HDX, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422024T4XSwitchEngine | 1.3.6.1.4.1.1916.2.493 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 24 10/100/1000BASET FDX/HDX, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422048T4XSwitchEngine | 1.3.6.1.4.1.1916.2.494 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 48 10/100/1000BASET FDX/HDX, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422012P4XSwitchEngine | 1.3.6.1.4.1.1916.2.495 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 12 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422024P4XSwitchEngine | 1.3.6.1.4.1.1916.2.496 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 24 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422048P4XSwitchEngine | 1.3.6.1.4.1.1916.2.497 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 48 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme42204MW8P4XSwitchEngine | 1.3.6.1.4.1.1916.2.498 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 4 1Gb/2.5Gb/5Gb 802.3bt, 8 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme42204MW20P4XSwitchEngine | 1.3.6.1.4.1.1916.2.499 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 4 1Gb/2.5Gb/5Gb 802.3bt, 20 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme42208MW40P4XSwitchEngine | 1.3.6.1.4.1.1916.2.500 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 8 1Gb/2.5Gb/5Gb 802.3bt, 40 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme42208XSwitchEngine | 1.3.6.1.4.1.1916.2.501 | |||
node · current ExtremeSwitching 4220 (SwitchEngine) 8 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme532024T4XXTSwitchEngine | 1.3.6.1.4.1.1916.2.502 | |||
node · current ExtremeSwitching 5320 (SwitchEngine) Extended Temperature (0-60C), 24 10/100/1000BASET FDX/HDX, 4 10G unpopulated SFP+, internal fixed PSU, fans, RPS support | ||||
| Nextreme532024T24S4XEXTSwitchEngine | 1.3.6.1.4.1.1916.2.503 | |||
node · current ExtremeSwitching 5320 (SwitchEngine) Extended Temperature (0-60C), 24 10/100/1000BASET FDX/HDX, 24 100/1G unpopulated SFP, 4 10G unpopulated SFP+, MACsec capable, internal fixed PSU, fans, RPS support | ||||
| NextremeONEOSProducts | 1.3.6.1.4.1.1916.2.504 | |||
node · current Platforms running Extreme ONE OS software | ||||
| Nextreme8series | 1.3.6.1.4.1.1916.2.504.1 | |||
node · current Extreme 8-series products running Extreme ONE OS software | ||||
| Nextreme873032D | 1.3.6.1.4.1.1916.2.504.1.1 | |||
node · current Extreme 8730 platform with 32 400G QSFP-DD, running Extreme ONE OS software | ||||
| Nextreme9series | 1.3.6.1.4.1.1916.2.504.2 | |||
node · current Extreme 9-series products running Extreme ONE OS software | ||||
| Nextreme9920 | 1.3.6.1.4.1.1916.2.504.2.1 | |||
node · current Extreme 9920 platform running Extreme ONE OS software | ||||
| Nextreme872032CSLXOS | 1.3.6.1.4.1.1916.2.505 | |||
node · current Extreme L2/L3 Switch/Router with SLX-OS, 32x100GE, QSFP28 model | ||||
| Nextreme852048YSLXOS | 1.3.6.1.4.1.1916.2.506 | |||
node · current Extreme L2/L3 Switch/Router with SLX-OS, 48x25G SFP28 + 8x100G QSFP28 | ||||
| Nextreme852048XTSLXOS | 1.3.6.1.4.1.1916.2.507 | |||
node · current Extreme L2/L3 Switch/Router with SLX-OS, 48x10G Base-T RJ45 + 6x100G QSFP28 | ||||
| Nextreme882040CSLXOS | 1.3.6.1.4.1.1916.2.508 | |||
node · current Extreme L2/L3 Switch/Router with SLX-OS, 40x100G QSFP28 | ||||
| Nextreme882080CSLXOS | 1.3.6.1.4.1.1916.2.509 | |||
node · current Extreme L2/L3 Switch/Router with SLX-OS, 80x100G QSFP28 | ||||
| NextremeUCPx1130C | 1.3.6.1.4.1.1916.2.510 | |||
node · current Extreme Universal Compute Platform 1130C Appliance - Software distribution and orchestration platform for network edge computing. | ||||
| NextremeUCPx2130C | 1.3.6.1.4.1.1916.2.511 | |||
node · current Extreme Universal Compute Platform 2130C Appliance - Software distribution and orchestration platform for network edge computing. | ||||
| NextremeUCPx3150C | 1.3.6.1.4.1.1916.2.512 | |||
node · current Extreme Universal Compute Platform 3150C Appliance - Software distribution and orchestration platform for network edge computing. | ||||
| NextremeXCCxCE1000 | 1.3.6.1.4.1.1916.2.513 | |||
node · current ExtremeCloud IQ Controller CE1000 - Premium management platform for the entry-tier on-premise Campus wireless deployment for UCP Small Scale Platform installs. | ||||
| NextremeXCCxCE2000 | 1.3.6.1.4.1.1916.2.514 | |||
node · current ExtremeCloud IQ Controller CE2000 - Premium management platform for the mid-tier on-premise Campus wireless deployment for UCP Medium Scale Platform installs. | ||||
| NextremeXCCx3125 | 1.3.6.1.4.1.1916.2.515 | |||
node · current ExtremeCloud IQ Controller E3125 - Premium management platform for the high-end tier on-premise Campus wireless deployment. | ||||
| Nextreme752048YE8CESwitchEngine | 1.3.6.1.4.1.1916.2.516 | |||
node · current 7520-48YE-8CE (Switch Engine) with 48 10Gb/25Gb SFP28, 8 40Gb/100Gb QSFP28, MACSec capable, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme752048YE8CEFabricEngine | 1.3.6.1.4.1.1916.2.517 | |||
node · current 7520-48YE-8CE (Fabric Engine) with 48 1Gb/10Gb/25Gb SFP28, 8 40Gb/100Gb QSFP28, MACSec capable, 2 unpopulated modular PSU slots, 6 unpopulated fan slots | ||||
| Nextreme552024TACDCSwitchEngine | 1.3.6.1.4.1.1916.2.518 | |||
node · current ExtremeSwitching 5520-24T-ACDC (Switch Engine) with 24 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme552048TACDCSwitchEngine | 1.3.6.1.4.1.1916.2.519 | |||
node · current ExtremeSwitching 5520-48T-ACDC (Switch Engine) with 48 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme552024XACDCSwitchEngine | 1.3.6.1.4.1.1916.2.520 | |||
node · current ExtremeSwitching 5520-24X-ACDC (Switch Engine) with 24 100/1000BASE-X unpopulated SFP ports upgradeable to 10Gb SFP+, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme552048SEACDCSwitchEngine | 1.3.6.1.4.1.1916.2.521 | |||
node · current ExtremeSwitching 5520-48SE-ACDC (Switch Engine) with 48 100/1000BASE-X MACsec capable SFP ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme552024TACDCFabricEngine | 1.3.6.1.4.1.1916.2.522 | |||
node · current ExtremeSwitching 5520-24T-ACDC (Fabric Engine) with 24 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme552048TACDCFabricEngine | 1.3.6.1.4.1.1916.2.523 | |||
node · current ExtremeSwitching 5520-48T-ACDC (Fabric Engine) with 48 10/100/1000BASE-T FDX/HDX MACsec capable ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme552024XACDCFabricEngine | 1.3.6.1.4.1.1916.2.524 | |||
node · current ExtremeSwitching 5520-24X-ACDC (Fabric Engine) with 24 100/1000BASE-X/10GBASE-X SFP+, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme552048SEACDCFabricEngine | 1.3.6.1.4.1.1916.2.525 | |||
node · current ExtremeSwitching 5520-48SE-ACDC (Fabric Engine) with 48 100/1000BASE-X MACsec capable SFP ports, two stacking/QSFP28 Universal Ethernet ports, 1 VIM slot, two ACDC unpopulated power supplies. | ||||
| Nextreme412024MW4YSwitchEngine | 1.3.6.1.4.1.1916.2.526 | |||
node · current ExtremeSwitching 4120 (SwitchEngine) 24 10Mb/100Mb/1Gb/2.5Gb 802.3bt 90W PoE, 4 1Gb/10Gb/25Gb SFP28 ports, 2 stacking/QSFP28 Universal Ethernet ports, fans, 1 fixed AC PSU, 1 unpopulated modular PSU slot | ||||
| Nextreme412048MW4YSwitchEngine | 1.3.6.1.4.1.1916.2.527 | |||
node · current ExtremeSwitching 4120 (SwitchEngine) 48 10Mb/100Mb/1Gb/2.5Gb 802.3bt 90W PoE, 4 1Gb/10Gb/25Gb SFP28 ports, 2 stacking/QSFP28 Universal Ethernet ports, fans, 1 fixed AC PSU, 1 unpopulated modular PSU slot | ||||
| NextremeSwitchEngine4120Stack | 1.3.6.1.4.1.1916.2.528 | |||
node · current A stacked version of Switch Engine 4120-based switches | ||||
| NextremeSwitchEngine4220Stack | 1.3.6.1.4.1.1916.2.529 | |||
node · current A stacked version of Switch Engine 4220-based switches | ||||
| Nextreme422012T4XFabricEngine | 1.3.6.1.4.1.1916.2.530 | |||
node · current ExtremeSwitching 4220 (FabricEngine) 12 10/100/1000BASET FDX/HDX, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422024T4XFabricEngine | 1.3.6.1.4.1.1916.2.531 | |||
node · current ExtremeSwitching 4220 (FabricEngine) 24 10/100/1000BASET FDX/HDX, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422012P4XFabricEngine | 1.3.6.1.4.1.1916.2.532 | |||
node · current ExtremeSwitching 4220 (FabricEngine) 12 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme422024P4XFabricEngine | 1.3.6.1.4.1.1916.2.533 | |||
node · current ExtremeSwitching 4220 (FabricEngine) 24 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme42204MW8P4XFabricEngine | 1.3.6.1.4.1.1916.2.534 | |||
node · current ExtremeSwitching 4220 (FabricEngine) 4 1Gb/2.5Gb/5Gb 802.3bt, 8 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme42204MW20P4XFabricEngine | 1.3.6.1.4.1.1916.2.535 | |||
node · current ExtremeSwitching 4220 (FabricEngine) 4 1Gb/2.5Gb/5Gb 802.3bt, 20 10/100/1000BASET FDX/HDX PoE+, 4 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme42208XFabricEngine | 1.3.6.1.4.1.1916.2.536 | |||
node · current ExtremeSwitching 4220 (FabricEngine) 8 10G unpopulated SFP+, internal fixed PSU, fans | ||||
| Nextreme532024T4XXTFabricEngine | 1.3.6.1.4.1.1916.2.537 | |||
node · current ExtremeSwitching 5320 (FabricEngine) Extended Temperature (0-60C), 24 10/100/1000BASET FDX/HDX, 4 10G unpopulated SFP+, internal fixed PSU, fans, RPS support | ||||
| Nextreme532024T24S4XEXTFabricEngine | 1.3.6.1.4.1.1916.2.538 | |||
node · current ExtremeSwitching 5320 (FabricEngine) Extended Temperature (0-60C), 24 10/100/1000BASET FDX/HDX, 24 100/1G unpopulated SFP, 4 10G unpopulated SFP+, MACsec capable, internal fixed PSU, fans, RPS support | ||||
| Nextreme512044X4Y2CSwitchEngine | 1.3.6.1.4.1.1916.2.539 | |||
node · current ExtremeSwitching 5120 (SwitchEngine) 44 1G/10G SFP+ ports, 4 10G/25G SFP28 ports, 2 100G QSFP28 Universal/Stacking ports, MACSEC capable, 6 unpopulated fan slots, 2 unpopulated modular PSU slots | ||||
| Nextreme512024X4YSwitchEngine | 1.3.6.1.4.1.1916.2.540 | |||
node · current ExtremeSwitching 5120 (SwitchEngine) 24 1G/10G SFP+ ports, 4 10G/25G SFP28 ports, MACSEC capable, 4 unpopulated fan slots, 2 unpopulated modular PSU slots | ||||
| Nextreme512024XT4YSwitchEngine | 1.3.6.1.4.1.1916.2.541 | |||
node · current ExtremeSwitching 5120 (SwitchEngine) 24 1G/10GBase-T Non-PoE ports, 4 10G/25G SFP28 ports, MACSEC capable, 4 unpopulated fan slots, 2 unpopulated modular PSU slots | ||||
| NextremeSwitchEngine5120Stack | 1.3.6.1.4.1.1916.2.542 | |||
node · current A stacked version of Switch Engine 5120-based switches | ||||
| Nextreme532016P2MXT2XFabricEngine | 1.3.6.1.4.1.1916.2.543 | |||
node · current ExtremeSwitching 5320 (FabricEngine) with 16 10/100/1000Base-T FDX/HDX PoE+ ports, 2 1G/2.5G/5G/10G Base-T ports and 2 10G SFP+ uplink ports, 1 internal AC PSU, Fanless | ||||
| NextremeUCPx3160C | 1.3.6.1.4.1.1916.2.544 | |||
node · current Extreme Universal Compute Platform 3160C Appliance - Software distribution and orchestration platform for network edge computing. | ||||
| Nextreme532016P2MXT2XSwitchEngine | 1.3.6.1.4.1.1916.2.545 | |||
node · current ExtremeSwitching 5320 (SwitchEngine) with 16 10/100/1000Base-T FDX/HDX PoE+ ports, 2 1G/2.5G/5G/10G Base-T ports and 2 10G SFP+ uplink ports, 1 internal AC PSU, Fanless | ||||
| Nextreme783032CE8DEFabricEngine | 1.3.6.1.4.1.1916.2.546 | |||
node · current 7830-32CE-8DE (FabricEngine) with 32x100Gb QSFP28, 8x400Gb QSFPDD, 2 unpopulated modular PSU slots, 4 unpopulated fan slots, 2 VIM Slots | ||||
| Nextreme5420M24W24S4YEFabricEngine | 1.3.6.1.4.1.1916.2.547 | |||
node · current ExtremeSwitching 5420M (FabricEngine) with 24 10/100/1000 BASE-T 90W PoE w/ Half Duplex on 10/100M ports, 24 100M (FX/LX)/1G SFP, 4 1/10/25G unpopulated SFP28 ports, MACSec capable, unpopulated Dual Modular PSUs and Modular Fans (F2B only) | ||||
| NextremeX465Stack | 1.3.6.1.4.1.1916.2.548 | |||
node · current A stacked version of EXOS X465 switches | ||||
| Nextreme5420M24W24S4YESwitchEngine | 1.3.6.1.4.1.1916.2.549 | |||
node · current ExtremeSwitching 5420M (SwitchEngine) with 24 10/100/1000 BASE-T 90W PoE w/ Half Duplex on 10/100M ports, 24 100M (FX/LX)/1G SFP, 4 1/10/25G unpopulated SFP28 ports, 2 stacking/ SFP-DD Universal Ethernet ports, MACSec capable, unpopulated Dual Modular PSUs and Modular Fans (F2B only) | ||||
| NextremeMisc | 1.3.6.1.4.1.1916.3 | |||
| NextremeOids | 1.3.6.1.4.1.1916.3.1 | |||
| NextremeMauType | 1.3.6.1.4.1.1916.3.1.1 | |||
| NextremeMauType1000BaseSX | 1.3.6.1.4.1.1916.3.1.1.1 | |||
| NextremeMauType1000BaseLX | 1.3.6.1.4.1.1916.3.1.1.2 | |||
| NextremeMauType1000BaseCX | 1.3.6.1.4.1.1916.3.1.1.3 | |||
| NextremeMauType1000BaseSXFD | 1.3.6.1.4.1.1916.3.1.1.4 | |||
| NextremeMauType1000BaseLXFD | 1.3.6.1.4.1.1916.3.1.1.5 | |||
| NextremeMauType1000BaseCXFD | 1.3.6.1.4.1.1916.3.1.1.6 | |||
| NextremeMauType1000BaseWDMHD | 1.3.6.1.4.1.1916.3.1.1.7 | |||
| NextremeMauType1000BaseWDMFD | 1.3.6.1.4.1.1916.3.1.1.8 | |||
| NextremeMauType1000BaseLX70HD | 1.3.6.1.4.1.1916.3.1.1.9 | |||
| NextremeMauType1000BaseLX70FD | 1.3.6.1.4.1.1916.3.1.1.10 | |||
| NextremeMauType1000BaseZXHD | 1.3.6.1.4.1.1916.3.1.1.11 | |||
| NextremeMauType1000BaseZXFD | 1.3.6.1.4.1.1916.3.1.1.12 | |||
| NextremeMauType1000BaseLX100HD | 1.3.6.1.4.1.1916.3.1.1.13 | |||
| NextremeMauType1000BaseLX100FD | 1.3.6.1.4.1.1916.3.1.1.14 | |||
| NextremeMauType10GBaseCX4 | 1.3.6.1.4.1.1916.3.1.1.15 | |||
| NextremeMauType10GBaseZR | 1.3.6.1.4.1.1916.3.1.1.16 | |||
| NextremeMauType10GBaseDWDM | 1.3.6.1.4.1.1916.3.1.1.17 | |||
| NextremeMauType10GBaseCX | 1.3.6.1.4.1.1916.3.1.1.18 | |||
| NextremeMauType10GBaseT | 1.3.6.1.4.1.1916.3.1.1.19 | |||
| NextremeMauType40GBaseX | 1.3.6.1.4.1.1916.3.1.1.20 | |||
| NextremeMauType100GBaseX | 1.3.6.1.4.1.1916.3.1.1.21 | |||
| NextremeMauType40GBasePSM4 | 1.3.6.1.4.1.1916.3.1.1.22 | |||
| NextremeMauType100GBaseSR4 | 1.3.6.1.4.1.1916.3.1.1.23 | |||
| NextremeMauType100GBaseCR4 | 1.3.6.1.4.1.1916.3.1.1.24 | |||
| NextremeMauType100GBaseCWDM4 | 1.3.6.1.4.1.1916.3.1.1.25 | |||
| NextremeMauType100GBasePSM4 | 1.3.6.1.4.1.1916.3.1.1.32 | |||
| NextremeMauType100GBaseSWDM4 | 1.3.6.1.4.1.1916.3.1.1.33 | |||
| NextremeMauType25GBaseSR | 1.3.6.1.4.1.1916.3.1.1.34 | |||
| NextremeMauType25GBaseESR | 1.3.6.1.4.1.1916.3.1.1.35 | |||
| NextremeMauType25GBaseLR | 1.3.6.1.4.1.1916.3.1.1.36 | |||
| NextremeMauType25GBaseCR4 | 1.3.6.1.4.1.1916.3.1.1.37 | |||
| NextremeMauType100GBaseCWDM4Lite | 1.3.6.1.4.1.1916.3.1.1.38 | |||
| NextremeMauType100GBaseBIDI | 1.3.6.1.4.1.1916.3.1.1.39 | |||
| NextremeMauType10GBaseBX10U | 1.3.6.1.4.1.1916.3.1.1.40 | |||
| NextremeMauType10GBaseBX10D | 1.3.6.1.4.1.1916.3.1.1.41 | |||
| NextremeMauType10GBaseBX40U | 1.3.6.1.4.1.1916.3.1.1.42 | |||
| NextremeMauType10GBaseBX40D | 1.3.6.1.4.1.1916.3.1.1.43 | |||
| NextremeMauType100GBase4WDM10KM | 1.3.6.1.4.1.1916.3.1.1.44 | |||
| NextremeMauType100GBase4WDM20KM | 1.3.6.1.4.1.1916.3.1.1.45 | |||
| NextremeMauType100GBase4WDM40KM | 1.3.6.1.4.1.1916.3.1.1.46 | |||
| NextremeV2Traps | 1.3.6.1.4.1.1916.4 | |||
Textual conventions
ClientAuthTypeINTEGERdot1x(4)mac-based(3)none(0)open(1)web-based(6)wep(2)wpa(8)wpa-psk(5)wpa2(7)wpa2-psk(9)Type of client specified in the netlogin traps as well as the client table. For wired clients, only none, netlogin and dot1x are valid
ExtremeDeviceIdOCTET STRING (SIZE (8))The switch identifier used by Extreme EDP protocol.
ExtremeGenAddrOCTET STRING (SIZE (0..20))The value of an address.
L4PortINTEGER (0 | 1..65535)The value of a transport layer (layer-4) port number, in network byte order. A value of 0 indicates all allowed values of this field i.e. wildcard.
PortListOCTET STRINGEach octet within this value specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the bridge is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'. If the object has a length of 0 then it is taken to refer to all of the ports in a given device.
WPACipherSetBitsccmp(4)none(0)other(6)tkip(2)wep128(5)wep64(1)wrap(3)A set of supported ciphers which can be advertised by WPA stations. Each set bit indicates support for a given cipher suite. The special value none is allowed for representing the absence of information. The value other is used to indicate an unknown cipher.
WPAKeyMgmtSetBitsdot1x(1)none(0)psk(2)A set of supported key management suites. For more info see IEEE 802.11i D3.0 section 7.
WirelessRemoteConnectBindingTypeINTEGERip-address(3)mac-address(1)none(0)serial-number(2)The type of binding to be used when mapping APs to virtual ports
Used by
- EXTREME-CABLE-MIB
- EXTREME-DLCS-MIB
- EXTREME-DOS-MIB
- EXTREME-EAPS-MIB
- EXTREME-EDP-MIB
- EXTREME-ENH-DOS-MIB
- EXTREME-ENTITY-MIB
- EXTREME-ESRP-MIB
- EXTREME-FDB-MIB
- EXTREME-FILETRANSFER-MIB
- EXTREME-NETFLOW-MIB
- EXTREME-NP-MIB
- EXTREME-OSPF-MIB
- EXTREME-PBQOS-MIB
- EXTREME-POE-MIB
- EXTREME-PORT-MIB
- EXTREME-POS-MIB
- EXTREME-QOS-MIB
- EXTREME-RTSTATS-MIB
- EXTREME-SERVICES-MIB
- EXTREME-SLB-MIB
- EXTREME-SNMPV3-MIB
- EXTREME-SOFTWARE-MONITOR-MIB
- EXTREME-STACKING-MIB
- EXTREME-STP-EXTENSIONS-MIB
- EXTREME-SYSTEM-MIB
- EXTREME-TRAP-MIB
- EXTREME-TRAPPOLL-MIB
- EXTREME-V2TRAP-MIB
- EXTREME-VC-MIB
- EXTREME-VLAN-MIB
- EXTREME-WIRELESS-MIB
- EXTREMEdot11AP-MIB
- EXTREMEdot11f-MIB