MIB Browser
Defines common textual conventions used in RBN mib
modules.
Organization
Ericsson AB.
Root OID
1.3.6.1.4.1.2352.5.2
Last updated
Objects
1
Source
Show full MIB
snmptranslate -m RBN-TC -Tp
snmpwalk -v2c -c <community> -m RBN-TC <host> 1.3.6.1.4.1.2352.5.2

Imports

RBN-SMIrbnModules
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatus
IrbnTC1.3.6.1.4.1.2352.5.2

Textual conventions

RbnCircuitHandle OCTET STRING (SIZE (8))

Display hint: 1d:1d:2x-2x-2x

A unique identifier for individual circuits. The string is
composed of the following:

    Octet 1     slot
          2     port
          3-8   circuit identifier

slots/ports are numbered 0..n. The SMS CLI also numbers slots/ports
0..n but SE CLI numbers slots/ports 1..n. For example: When the
SE CLI refers to slot/port 1/2, this maps to to the RbnCircuitHandle
slot/port 0/1
RbnKBytes Integer32 (0..2147483647)

Display hint: d

Storage size, expressed in units of 1024 bytes.
RbnPercentage Integer32 (0..100)

Display hint: d%

This Textual Convention describes an object that stores
a whole integer percentage value.
RbnPort Unsigned32 (0..255)

Display hint: d

The chassis port number.  This is the physical port
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE.
RbnPortMediumType INTEGER

cable(12) dsl(11) satellite(14) unknown(0) wireless(13)

Medium type of NAS port.
RbnSlot Unsigned32 (0..255)

Display hint: d

The chassis slot number.  This is the physical slot
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE.
RbnUnsigned64 OCTET STRING (SIZE (8))

Display hint: 8d

Unsigned 64 bit integer value is represented as an
OCTET STRING.  This allows an unsigned integer value in
the range 0..18446744073709551615.

The octets are ordered with the first octet containing
the highest ordered bits of the integer and the 8th octet
containing the lowest ordered bits, corresponding to
network byte order.
RbnVidOrUntagged Integer32 (1..4096)

Display hint: d

The twelve-bit VLAN Identifer (VID) used to uniquely
identify the VLAN to which the frame belongs.  The VID is
encoded as an unsigned binary number.  An untagged frame
does not carry any identification of the VLAN to which it
belongs and is designated with a value of 4096.

Used by