MIB Browser
The MIB used to genericially manage Environmental
Monitor functionality on network devices.
Organization
Ericsson AB.
Root OID
1.3.6.1.4.1.2352.2.4
Last updated
Objects
56
Source
Show full MIB
snmptranslate -m RBN-ENVMON-MIB -Tp
snmpwalk -v2c -c <community> -m RBN-ENVMON-MIB <host> 1.3.6.1.4.1.2352.2.4

Imports

ENTITY-MIBentPhysicalIndex
RBN-SMIrbnMgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue

OID tree

NameOIDTypeAccessStatus
IrbnEnvMonMIB1.3.6.1.4.1.2352.2.4
NrbnEnvMonMIBNotifications1.3.6.1.4.1.2352.2.4.0
!rbnFanFailChange1.3.6.1.4.1.2352.2.4.0.1deprecated
!rbnPowerFailChange1.3.6.1.4.1.2352.2.4.0.2deprecated
!rbnFanStatusChange1.3.6.1.4.1.2352.2.4.0.3
!rbnPowerStatusChange1.3.6.1.4.1.2352.2.4.0.4
NrbnEnvMonMIBObjects1.3.6.1.4.1.2352.2.4.1
TrbnFanStatusTable1.3.6.1.4.1.2352.2.4.1.1NA
RrbnFanStatusEntry1.3.6.1.4.1.2352.2.4.1.1.1NA
CrbnFanIndex1.3.6.1.4.1.2352.2.4.1.1.1.1Integer32 (1..2147483647)NA
CrbnFanDescr1.3.6.1.4.1.2352.2.4.1.1.1.2DisplayString (SIZE (0..32))RO
CrbnFanFail1.3.6.1.4.1.2352.2.4.1.1.1.3TruthValueROdeprecated
CrbnFanStatus1.3.6.1.4.1.2352.2.4.1.1.1.4INTEGERRO
TrbnPowerStatusTable1.3.6.1.4.1.2352.2.4.1.2NA
RrbnPowerStatusEntry1.3.6.1.4.1.2352.2.4.1.2.1NA
CrbnPowerIndex1.3.6.1.4.1.2352.2.4.1.2.1.1Integer32 (1..2147483647)NA
CrbnPowerDescr1.3.6.1.4.1.2352.2.4.1.2.1.2DisplayString (SIZE (0..32))RO
CrbnPowerFail1.3.6.1.4.1.2352.2.4.1.2.1.3TruthValueROdeprecated
CrbnPowerStatus1.3.6.1.4.1.2352.2.4.1.2.1.4INTEGERRO
TrbnVoltageSensorTable1.3.6.1.4.1.2352.2.4.1.3NA
RrbnVoltageSensorEntry1.3.6.1.4.1.2352.2.4.1.3.1NA
CrbnVoltageIndex1.3.6.1.4.1.2352.2.4.1.3.1.1Integer32 (1..2147483647)NA
CrbnVoltageDescr1.3.6.1.4.1.2352.2.4.1.3.1.2DisplayString (SIZE (0..48))RO
CrbnVoltageDesired1.3.6.1.4.1.2352.2.4.1.3.1.3RbnVoltageRO
CrbnVoltageCurrent1.3.6.1.4.1.2352.2.4.1.3.1.4RbnVoltageRO
TrbnCpuTempSensorTable1.3.6.1.4.1.2352.2.4.1.4NAdeprecated
RrbnCpuTempSensorEntry1.3.6.1.4.1.2352.2.4.1.4.1NAdeprecated
CrbnCpuTempIndex1.3.6.1.4.1.2352.2.4.1.4.1.1Integer32 (1..2147483647)NAdeprecated
CrbnCpuTempDescr1.3.6.1.4.1.2352.2.4.1.4.1.2DisplayString (SIZE (0..48))ROdeprecated
CrbnCpuTempCurrent1.3.6.1.4.1.2352.2.4.1.4.1.3RbnTemperatureROdeprecated
TrbnFanSpeedTable1.3.6.1.4.1.2352.2.4.1.5NA
RrbnFanSpeedEntry1.3.6.1.4.1.2352.2.4.1.5.1NA
CrbnFanUnitID1.3.6.1.4.1.2352.2.4.1.5.1.1Integer32 (1..2147483647)NA
CrbnFanUnitDescr1.3.6.1.4.1.2352.2.4.1.5.1.2DisplayString (SIZE (0..32))RO
CrbnFanSpeedCurrent1.3.6.1.4.1.2352.2.4.1.5.1.3RbnFanSpeedRO
TrbnEntityTempSensorTable1.3.6.1.4.1.2352.2.4.1.6NA
RrbnEntityTempSensorEntry1.3.6.1.4.1.2352.2.4.1.6.1NA
CrbnEntityTempIndex1.3.6.1.4.1.2352.2.4.1.6.1.1Integer32 (1..2147483647)NA
CrbnEntityTempDescr1.3.6.1.4.1.2352.2.4.1.6.1.2DisplayString (SIZE (0..48))RO
CrbnEntityTempCurrent1.3.6.1.4.1.2352.2.4.1.6.1.3RbnTemperatureRO
NrbnEnvMonMIBConformance1.3.6.1.4.1.2352.2.4.2
NrbnEnvMonMIBGroups1.3.6.1.4.1.2352.2.4.2.1
GrbnEnvMonMIBObjectGroup1.3.6.1.4.1.2352.2.4.2.1.1deprecated
GrbnEnvMonMIBNotificationGroup1.3.6.1.4.1.2352.2.4.2.1.2deprecated
GrbnEnvMonVoltageObjectGroup1.3.6.1.4.1.2352.2.4.2.1.3
GrbnEnvMonTempObjectGroup1.3.6.1.4.1.2352.2.4.2.1.4deprecated
GrbnEnvMonMIBObjectGroupV21.3.6.1.4.1.2352.2.4.2.1.5
GrbnEnvMonMIBNotificationGroupV21.3.6.1.4.1.2352.2.4.2.1.6
GrbnEnvMonFanSpeedObjectGroup1.3.6.1.4.1.2352.2.4.2.1.7
GrbnEnvMonEntityObjectGroup1.3.6.1.4.1.2352.2.4.2.1.8
NrbnEnvMonMIBCompliances1.3.6.1.4.1.2352.2.4.2.2
MrbnEnvMonMIBCompliance1.3.6.1.4.1.2352.2.4.2.2.1obsolete
MrbnEnvMonMIBComplianceV21.3.6.1.4.1.2352.2.4.2.2.2deprecated
MrbnEnvMonMIBComplianceV31.3.6.1.4.1.2352.2.4.2.2.3deprecated
MrbnEnvMonMIBComplianceV41.3.6.1.4.1.2352.2.4.2.2.4deprecated
MrbnEnvMonMIBComplianceV51.3.6.1.4.1.2352.2.4.2.2.5

Textual conventions

RbnFanSpeed Unsigned32
Represents a fan speed value in units of Revolutions Per
Minute(RPM).
RbnTemperature Unsigned32 (0..100)

Display hint: d

Represents a temperature, in degrees Celsius. In the
unlikely event that the temperature to be reported is
less than 0 degrees Celsius, a value of 0 will be
used. Likewise, if the temperature is greater than
100, a value of 100 will be used.
RbnVoltage Unsigned32 (0..50000)
Represents a voltage value. The value is millivolts.
For example, a voltage of 5.5V would be represented
by the value 5500.