CTRON-CHASSIS-MIB
Enterasys Networks Inc.snmptranslate -m CTRON-CHASSIS-MIB -Tpsnmpwalk -v2c -c <community> -m CTRON-CHASSIS-MIB <host> 1.3.6.1.4.1.52.4.3.1.1Imports
| CTRON-MIB-NAMES | ctronChassis |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| NctChas | 1.3.6.1.4.1.52.4.3.1.1 | |||
| SctChasFNB | 1.3.6.1.4.1.52.4.3.1.1.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Denotes the presence or absence of the FNB.
| ||||
| SctChasAlarmEna | 1.3.6.1.4.1.52.4.3.1.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Allow an audible alarm to be either enabled or dis- abled. Setting this object to disable(1) will prevent an audible alarm from being heard and will also stop the sound from a current audible alarm. Setting this object to enable(2) will allow an audible alarm to be heard and will also enable the sound from a current audible alarm, if it has previously been disabled. This object will read with the current setting.
| ||||
| SchassisAlarmState | 1.3.6.1.4.1.52.4.3.1.1.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Denotes the current condition of the power supply fault detection circuit. This object will read with the value of chassisNoFaultCondition(1) when the chassis is currently operating with no power faults detected. This object will read with the value of chassisFaultCondition(2) when the chassis is currently in a power fault condition.
| ||||
| NctEnviron | 1.3.6.1.4.1.52.4.3.1.2 | |||
| TctChasPowerTable | 1.3.6.1.4.1.52.4.3.1.2.1 | NA | mandatory | |
table · not-accessible · mandatory A list of power supply entries. | ||||
| RctChasPowerEntry | 1.3.6.1.4.1.52.4.3.1.2.1.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the powerTable providing objects for a power supply.
| ||||
| CctChasPowerSupplyNum | 1.3.6.1.4.1.52.4.3.1.2.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Denotes the power supply. | ||||
| CctChasPowerSupplyState | 1.3.6.1.4.1.52.4.3.1.2.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Denotes the power supply's state.
| ||||
| CctChasPowerSupplyType | 1.3.6.1.4.1.52.4.3.1.2.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Denotes the power supply type.
| ||||
| CctChasPowerSupplyRedundancy | 1.3.6.1.4.1.52.4.3.1.2.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Denotes whether or not the power supply is redundant.
| ||||
| NctFanModule | 1.3.6.1.4.1.52.4.3.1.3 | |||
| TctChasFanModuleTable | 1.3.6.1.4.1.52.4.3.1.3.1 | NA | mandatory | |
table · not-accessible · mandatory A list of fan module entries. | ||||
| RctChasFanModuleEntry | 1.3.6.1.4.1.52.4.3.1.3.1.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the fan module Table providing objects for a fan module.
| ||||
| CctChasFanModuleNum | 1.3.6.1.4.1.52.4.3.1.3.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Denotes the Fan module that may have failed. | ||||
| CctChasFanModuleState | 1.3.6.1.4.1.52.4.3.1.3.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Denotes the fan modules state.
| ||||