MIB Browser

ENDACE-MODULE-MIB

Endace Technology
This MIB handles information about DAG Modules in Endace
appliances, formerly known as 'Shogun'.
Organization
Endace Technology
Root OID
1.3.6.1.4.1.18418.2
Last updated
Objects
91
Source
Show full MIB
snmptranslate -m ENDACE-MODULE-MIB -Tp
snmpwalk -v2c -c <community> -m ENDACE-MODULE-MIB <host> 1.3.6.1.4.1.18418.2

Imports

ENDACE-MIBendace
ENDACEModuleType-MIBEndaceModuleType
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Counter32, Counter64, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue

OID tree

NameOIDTypeAccessStatusExample
IshogunModuleMIB1.3.6.1.4.1.18418.2
NmoduleMIBObjects1.3.6.1.4.1.18418.2.1
TmoduleTable1.3.6.1.4.1.18418.2.1.1NA
RmoduleTableEntry1.3.6.1.4.1.18418.2.1.1.1NA
CmoduleIndex1.3.6.1.4.1.18418.2.1.1.1.1ModuleIndexRO
CmoduleName1.3.6.1.4.1.18418.2.1.1.1.2DisplayString (SIZE (0..255))RO
CmoduleType1.3.6.1.4.1.18418.2.1.1.1.3EndaceModuleTypeRO
CmoduleActiveFirmware1.3.6.1.4.1.18418.2.1.1.1.4DisplayStringRO
CmoduleOperStatus1.3.6.1.4.1.18418.2.1.1.1.5INTEGERRO
CmoduleLastChange1.3.6.1.4.1.18418.2.1.1.1.6TimeTicksRO
CmoduleSnapLen1.3.6.1.4.1.18418.2.1.1.1.7Unsigned32ROobsolete
CmoduleTemperature1.3.6.1.4.1.18418.2.1.1.1.8Unsigned32RO
CmoduleVoltage1.3.6.1.4.1.18418.2.1.1.1.9Unsigned32NAdeprecated
NmoduleInterfaces1.3.6.1.4.1.18418.2.1.2
TmodifTable1.3.6.1.4.1.18418.2.1.2.1NA
RmodifEntry1.3.6.1.4.1.18418.2.1.2.1.1NA
CmodifModIndex1.3.6.1.4.1.18418.2.1.2.1.1.1InterfaceIndexRO
CmodifPortLabel1.3.6.1.4.1.18418.2.1.2.1.1.2DisplayString (SIZE (2))RO
CmodifModule1.3.6.1.4.1.18418.2.1.2.1.1.3Integer32RO
CmodifName1.3.6.1.4.1.18418.2.1.2.1.1.4DisplayString (SIZE (0..255))RO
CmodifType1.3.6.1.4.1.18418.2.1.2.1.1.5EndaceifTypeRO
CmodifMtu1.3.6.1.4.1.18418.2.1.2.1.1.6Integer32RO
CmodifInAdminStatus1.3.6.1.4.1.18418.2.1.2.1.1.7INTEGERRO
CmodifInOperStatus1.3.6.1.4.1.18418.2.1.2.1.1.8INTEGERRO
CmodifLastChange1.3.6.1.4.1.18418.2.1.2.1.1.9TimeTicksNAdeprecated
CmodifLinkUpDownTrapEnable1.3.6.1.4.1.18418.2.1.2.1.1.10INTEGERRO
CmodifLinkDropThreshold1.3.6.1.4.1.18418.2.1.2.1.1.11Gauge32NAdeprecated
CmodifSpeed1.3.6.1.4.1.18418.2.1.2.1.1.12Gauge32RO
CmodifHighSpeed1.3.6.1.4.1.18418.2.1.2.1.1.13Gauge32ROobsolete
CmodifInOctets1.3.6.1.4.1.18418.2.1.2.1.1.14Counter32ROdeprecated
CmodifInPackets1.3.6.1.4.1.18418.2.1.2.1.1.15Counter32ROdeprecated
CmodifInDropPackets1.3.6.1.4.1.18418.2.1.2.1.1.16Counter32ROdeprecated
CmodifOutOctets1.3.6.1.4.1.18418.2.1.2.1.1.17Counter32ROdeprecated
CmodifOutPackets1.3.6.1.4.1.18418.2.1.2.1.1.18Counter32ROdeprecated
CmodifHCInOctets1.3.6.1.4.1.18418.2.1.2.1.1.19Counter64RO
CmodifHCInPackets1.3.6.1.4.1.18418.2.1.2.1.1.20Counter64RO
CmodifHCInDropPackets1.3.6.1.4.1.18418.2.1.2.1.1.21Counter64RO
CmodifHCOutOctets1.3.6.1.4.1.18418.2.1.2.1.1.22Counter64RO
CmodifHCOutPackets1.3.6.1.4.1.18418.2.1.2.1.1.23Counter64RO
CmodifCounterDiscontinuityTime1.3.6.1.4.1.18418.2.1.2.1.1.24TimeTicksRO
CmodifHCInErrors1.3.6.1.4.1.18418.2.1.2.1.1.25Counter64RO
CmodifUserLabel1.3.6.1.4.1.18418.2.1.2.1.1.26DisplayStringRO
CmodifPhysAddr1.3.6.1.4.1.18418.2.1.2.1.1.27PhysAddress (SIZE (0..18))RO
TmodoptTable1.3.6.1.4.1.18418.2.1.2.3NA
RmodoptEntry1.3.6.1.4.1.18418.2.1.2.3.1NA
CmodoptIndex1.3.6.1.4.1.18418.2.1.2.3.1.1Unsigned32NA1
CmodoptName1.3.6.1.4.1.18418.2.1.2.3.1.2DisplayStringROa
CmodoptDetect1.3.6.1.4.1.18418.2.1.2.3.1.3TruthValueRO1
CmodoptLOS1.3.6.1.4.1.18418.2.1.2.3.1.4TruthValueRO2
CmodoptRxPower1.3.6.1.4.1.18418.2.1.2.3.1.5DisplayStringRO-2.89 dBm
CmodoptRxPowerOk1.3.6.1.4.1.18418.2.1.2.3.1.6TruthValueRO1
CmodoptTxPower1.3.6.1.4.1.18418.2.1.2.3.1.7DisplayStringRO-2.38 dBm
CmodoptTxPowerOk1.3.6.1.4.1.18418.2.1.2.3.1.8TruthValueRO1
CmodoptTemp1.3.6.1.4.1.18418.2.1.2.3.1.9DisplayStringRO38 degrees C
CmodoptTempOk1.3.6.1.4.1.18418.2.1.2.3.1.10TruthValueRO1
CmodoptVolt1.3.6.1.4.1.18418.2.1.2.3.1.11DisplayStringRO3.27 V
CmodoptVoltOk1.3.6.1.4.1.18418.2.1.2.3.1.12TruthValueRO1
CmodoptCompliance1.3.6.1.4.1.18418.2.1.2.3.1.13DisplayStringRO10G Base-SR
NmoduleTraps11.3.6.1.4.1.18418.2.1.3
!modlinkUp1.3.6.1.4.1.18418.2.1.3.1
!modlinkDown1.3.6.1.4.1.18418.2.1.3.2
!dropFault1.3.6.1.4.1.18418.2.1.3.5
!dropNormal1.3.6.1.4.1.18418.2.1.3.6
!fcsFault1.3.6.1.4.1.18418.2.1.3.7
!fcsNormal1.3.6.1.4.1.18418.2.1.3.8
!remoteFault1.3.6.1.4.1.18418.2.1.3.9
!timestampConvDropFault1.3.6.1.4.1.18418.2.1.3.10obsolete
!timestampConvDropNormal1.3.6.1.4.1.18418.2.1.3.11obsolete
!syncLoss1.3.6.1.4.1.18418.2.1.3.13
!syncReturn1.3.6.1.4.1.18418.2.1.3.14
!inErrorFault1.3.6.1.4.1.18418.2.1.3.15
!inErrorNormal1.3.6.1.4.1.18418.2.1.3.16
NmoduleConformance1.3.6.1.4.1.18418.2.2
NmoduleGroups1.3.6.1.4.1.18418.2.2.1
GmoduleControlGroup1.3.6.1.4.1.18418.2.2.1.1
GifControlGroup1.3.6.1.4.1.18418.2.2.1.2
GifInPacketGroup1.3.6.1.4.1.18418.2.2.1.3deprecated
GifOutPacketGroup1.3.6.1.4.1.18418.2.2.1.4deprecated
GifInHCPacketGroup1.3.6.1.4.1.18418.2.2.1.5
GifOutHCPacketGroup1.3.6.1.4.1.18418.2.2.1.6
GifModCounterDiscontinuityGroup1.3.6.1.4.1.18418.2.2.1.7
GlinkTrapsGroup1.3.6.1.4.1.18418.2.2.1.8
GlinkTrapsDrop1.3.6.1.4.1.18418.2.2.1.9
GlinkTrapsErrors1.3.6.1.4.1.18418.2.2.1.10
GmodoptGroup1.3.6.1.4.1.18418.2.2.1.11
GmoduleTrapsState1.3.6.1.4.1.18418.2.2.1.12
GmodulePhysStatusGroup1.3.6.1.4.1.18418.2.2.1.16
GtimestampConvertNotifyGroup1.3.6.1.4.1.18418.2.2.1.17obsolete
GobsoleteGroup1.3.6.1.4.1.18418.2.2.1.18obsolete
NmoduleCompliances1.3.6.1.4.1.18418.2.2.2
MmoduleCompliance11.3.6.1.4.1.18418.2.2.2.1obsolete

Textual conventions

EndaceifType INTEGER

ethernet(1) ethernetLan(4) ethernetWan(5) pdh(3) sonet(2)

This data type is used as the type qualifier for each row in
the interface table. It provides a connection between the
interface type and interface specific table.
InterfaceIndex Unsigned32

Display hint: x

A unique value, greater then or equal to zero, for  each
interface in the managed system. It is recommended  that values
are assigned contiguously starting from 0.
ModuleIndex Unsigned32

Display hint: x

A unique value, greater then zero, for each module  in the
managed system. It is recommended that values  are assigned
according to chases slot number starting  from 1. Numbering
starting from 1 is due to legacy  restrictions.

Traps / Notifications

Groups and compliance

Used by