ENDACE-INVMGR-MIB
Endace TechnologyMIB for Investigation Manager Appliance Sources.
snmptranslate -m ENDACE-INVMGR-MIB -Tpsnmpwalk -v2c -c <community> -m ENDACE-INVMGR-MIB <host> 1.3.6.1.4.1.18418.15Imports
| ENDACE-MIB | endace |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IinvmgrMIB | 1.3.6.1.4.1.18418.15 | |||
identity MIB for Investigation Manager Appliance Sources. | ||||
| NinvmgrNotifications | 1.3.6.1.4.1.18418.15.0 | |||
| !invmgrConnectionChanged | 1.3.6.1.4.1.18418.15.0.1 | |||
notification · current The Investigation source Endace Appliance connection has changed. | ||||
| NinvmgrObjects | 1.3.6.1.4.1.18418.15.1 | |||
| TinvmgrApplStateTable | 1.3.6.1.4.1.18418.15.1.1 | NA | ||
table · not-accessible · current List of Endace Appliances used as Investigation Sources by the Investigation Manager. | ||||
| RinvmgrApplStateEntry | 1.3.6.1.4.1.18418.15.1.1.1 | NA | ||
row · not-accessible · current Entry for one Investigation Source Endace Appliance.
| ||||
| CinvmgrApplStateIndex | 1.3.6.1.4.1.18418.15.1.1.1.1 | INTEGER (1..32767) | NA | |
column · INTEGER (1..32767) · not-accessible · current Synthetic numeric unique ID of an Endace Appliance. | ||||
| CinvmgrApplStateName | 1.3.6.1.4.1.18418.15.1.1.1.2 | DisplayString | RO | |
column · DisplayString · read-only · current Textual ID/name of appliance. | ||||
| CinvmgrApplStateConnected | 1.3.6.1.4.1.18418.15.1.1.1.3 | TruthValue | RO | |
column · TruthValue · read-only · current Is Investigation Manager connected to this Endace Appliance? (2=no,1=yes) | ||||
| CinvmgrApplStateOK | 1.3.6.1.4.1.18418.15.1.1.1.4 | TruthValue | RO | |
column · TruthValue · read-only · current Did this Endace Appliance pass its most recent status check? (2=no,1=yes) | ||||
| TinvmgrApplConfigTable | 1.3.6.1.4.1.18418.15.1.2 | NA | ||
table · not-accessible · current List of configuration entries of Investigation Manager appliances. | ||||
| RinvmgrApplConfigEntry | 1.3.6.1.4.1.18418.15.1.2.1 | NA | ||
row · not-accessible · current Configuration for one Investigation Manager Source Endace Appliance. | ||||
| CinvmgrApplConfigIndex | 1.3.6.1.4.1.18418.15.1.2.1.1 | INTEGER (1..32767) | NA | |
column · INTEGER (1..32767) · not-accessible · current Synthetic numeric unique ID of Appliance. | ||||
| CinvmgrApplConfigName | 1.3.6.1.4.1.18418.15.1.2.1.2 | DisplayString | RO | |
column · DisplayString · read-only · current Textual ID/name of appliance. | ||||
| CinvmgrApplConfigEnabled | 1.3.6.1.4.1.18418.15.1.2.1.3 | TruthValue | RO | |
column · TruthValue · read-only · current Is this Endace Appliance enabled in the Investigation Manager? (1=yes, 2=no) | ||||
| NinvmgrConformance | 1.3.6.1.4.1.18418.15.2 | |||
| NinvmgrCompliances | 1.3.6.1.4.1.18418.15.2.1 | |||
| MinvmgrMandatory | 1.3.6.1.4.1.18418.15.2.1.1 | |||
compliance · current Mandatory groups for Investigation Manager Appliances.
| ||||
| NinvmgrGroups | 1.3.6.1.4.1.18418.15.2.2 | |||
| GinvmgrBasicObjects | 1.3.6.1.4.1.18418.15.2.2.1 | |||
group · current Investigation Manager basic objects. | ||||
| GinvmgrBasicEvents | 1.3.6.1.4.1.18418.15.2.2.2 | |||
Traps / Notifications
- invmgrConnectionChanged
1.3.6.1.4.1.18418.15.0.1