SP2-MIB
ELTEK Energy ASsnmptranslate -m SP2-MIB -Tpsnmpwalk -v2c -c <community> -m SP2-MIB <host> 1.3.6.1.4.1.12148.10Imports
| ELTEK-COMMON-MIB | eltek |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DateAndTime, DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NeNexus | 1.3.6.1.4.1.12148.10 | ||||||||||||||||||||
| NeltekTraps | 1.3.6.1.4.1.12148.10.1 | ||||||||||||||||||||
| NpowerAlarmVars | 1.3.6.1.4.1.12148.10.1.1 | ||||||||||||||||||||
| SalarmSubsysSourceDescr | 1.3.6.1.4.1.12148.10.1.1.1 | DisplayString (SIZE (0..32)) | AN | ||||||||||||||||||
scalar · DisplayString (SIZE (0..32)) · accessible-for-notify · current A description of the source generating the trap for the Alarm Condition. Used in alarmSubSystemTrap to describe the alarm source. Example: 'batteryVoltageDescription' | |||||||||||||||||||||
| SalarmSubsysStatusOid | 1.3.6.1.4.1.12148.10.1.1.2 | OBJECT IDENTIFIER | AN | ||||||||||||||||||
scalar · OBJECT IDENTIFIER · accessible-for-notify · current The OID (name) of the object indicating the alarm-status for which the alarm is generated. The Status must be an INTEGER type. Example: SP2-MIB::batteryVoltage.batteryVoltageStatus 1.3.6.1.4.1.12148.10.3.5.2: This object maybe polled by the SNMP management application, to monitor the current Status object. | |||||||||||||||||||||
| SalarmSubsysStatusValue | 1.3.6.1.4.1.12148.10.1.1.3 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The value of the Status object of the subsystem for which the alarm-status is generated. The OID (name) of this object is indicated by alarmSubsysStatusOid above. Example: the value of SP2-MIB::batteryVoltage.batteryVoltageStatus one of: error (0), normal (1), minorAlarm (2), etc.
| |||||||||||||||||||||
| SalarmSubsysStatusOnOff | 1.3.6.1.4.1.12148.10.1.1.4 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current This indicates if the abnormal condition is on or goes off.
| |||||||||||||||||||||
| SalarmMeasuredVarOid | 1.3.6.1.4.1.12148.10.1.1.5 | OBJECT IDENTIFIER | AN | ||||||||||||||||||
scalar · OBJECT IDENTIFIER · accessible-for-notify · current The OID (name) of the measured-object indicating some measurement (e.g voltage) for which the alarm is generated. Example: SP2-MIB::batteryVoltage.batteryVoltageValue 1.3.6.1.4.1.12148.10.3.5.1 This object maybe polled by the SNMP management application, to monitor the current measurement. | |||||||||||||||||||||
| SalarmMeasuredVarValue | 1.3.6.1.4.1.12148.10.1.1.6 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The value of the measured-object for which the alarm-status is generated, for example 13 volt. The actual value is in units defined by the actual variable (e.g volts). The units must use INTEGER type. The OID (name) of this object is indicated by alarmMeasuredVarOid above. Example: Value of SP2-MIB::batteryVoltage.batteryVoltageValue 'The measured battery voltage' | |||||||||||||||||||||
| SalarmTrapCounterVarValue | 1.3.6.1.4.1.12148.10.1.1.7 | Integer32 | AN | ||||||||||||||||||
| NpowerSystemTraps | 1.3.6.1.4.1.12148.10.1.2 | ||||||||||||||||||||
| !alarmPowerSystemTrap | 1.3.6.1.4.1.12148.10.1.2.1 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the power system. | |||||||||||||||||||||
| !alarmBatteryTrap | 1.3.6.1.4.1.12148.10.1.2.2 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the battery subsystem. | |||||||||||||||||||||
| !alarmLoadGroupTrap | 1.3.6.1.4.1.12148.10.1.2.3 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Load subsystem. | |||||||||||||||||||||
| !alarmMainsTrap | 1.3.6.1.4.1.12148.10.1.2.4 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Mains subsystem. | |||||||||||||||||||||
| !alarmRectifierTrap | 1.3.6.1.4.1.12148.10.1.2.5 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Rectifier subsystem. | |||||||||||||||||||||
| !alarmControlSystemTrap | 1.3.6.1.4.1.12148.10.1.2.6 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Control-system subsystem. | |||||||||||||||||||||
| !alarmDcDcTrap | 1.3.6.1.4.1.12148.10.1.2.7 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the DCDC converter subsystem. | |||||||||||||||||||||
| !alarmInputsTrap | 1.3.6.1.4.1.12148.10.1.2.8 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Inputs subsystem. | |||||||||||||||||||||
| !alarmOutputsTrap | 1.3.6.1.4.1.12148.10.1.2.9 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Outputs subsystem. | |||||||||||||||||||||
| !alarmGeneratorTrap | 1.3.6.1.4.1.12148.10.1.2.10 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Generator subsystem. | |||||||||||||||||||||
| !alarmSolarChargerTrap | 1.3.6.1.4.1.12148.10.1.2.11 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the SolarCharger subsystem. | |||||||||||||||||||||
| !alarmWindChargerTrap | 1.3.6.1.4.1.12148.10.1.2.12 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the WindCharger subsystem. | |||||||||||||||||||||
| !infoHeartBeatTrap | 1.3.6.1.4.1.12148.10.1.2.13 | ||||||||||||||||||||
notification · current When enabled, this trap will be transmitted at regular inervals. This trap is not intended to be an alarm but more like some information that the system is alive and the link is up.
| |||||||||||||||||||||
| !alarmInverterTrap | 1.3.6.1.4.1.12148.10.1.2.14 | ||||||||||||||||||||
notification · current This Trap is sent when an alarm condition occurs in the Rectifier subsystem. | |||||||||||||||||||||
| GpowerSystemTrapsGroup | 1.3.6.1.4.1.12148.10.1.3 | ||||||||||||||||||||
group · current The powerSystem Trap goup. Entry point for the trap list. | |||||||||||||||||||||
| NpowerSystem | 1.3.6.1.4.1.12148.10.2 | ||||||||||||||||||||
| SpowerSystemStatus | 1.3.6.1.4.1.12148.10.2.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current A status value showing the overall condition of the power system.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemType | 1.3.6.1.4.1.12148.10.2.2 | INTEGER | RO | smartpackS(2) | |||||||||||||||||
scalar · INTEGER · read-only · current A value showing the type of the power system, which is named after the main controller.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemMode | 1.3.6.1.4.1.12148.10.2.3 | INTEGER | RO | float(3) | |||||||||||||||||
scalar · INTEGER · read-only · current A summary status showing if the system is in test, boost, float, equalize, emergency or start-up delay mode
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemCompany | 1.3.6.1.4.1.12148.10.2.4 | DisplayString (SIZE (0..32)) | RW | <private> | |||||||||||||||||
scalar · DisplayString (SIZE (0..32)) · read-write · current The Copmany name (as stored in the Control Unit). Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemSite | 1.3.6.1.4.1.12148.10.2.5 | DisplayString (SIZE (0..32)) | RW | <private> | |||||||||||||||||
scalar · DisplayString (SIZE (0..32)) · read-write · current The system/site Location details (as stored in the Control Unit). Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemModel | 1.3.6.1.4.1.12148.10.2.6 | DisplayString (SIZE (0..32)) | RO | Micropack System | |||||||||||||||||
scalar · DisplayString (SIZE (0..32)) · read-only · current The model/part number of the power system (as stored in the Control Unit). Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemSerialNumber | 1.3.6.1.4.1.12148.10.2.7 | DisplayString (SIZE (0..16)) | RW | <private> | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current The serial number for the complete system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemInstallDate | 1.3.6.1.4.1.12148.10.2.8 | DateAndTime | RW | 07:e3:01:17:00:00:00:00 | |||||||||||||||||
scalar · DateAndTime · read-write · current The system's Installation date (as stored in the Control Unit). Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemNominalVoltage | 1.3.6.1.4.1.12148.10.2.9 | Integer32 | RO | 48 | |||||||||||||||||
scalar · Integer32 · read-only · current The nominal voltage rating. 12V/24V/48V/60V/110V/220V/380V etc. systems. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemLongitude | 1.3.6.1.4.1.12148.10.2.10 | Integer32 (-180..180) | RW | 0 | |||||||||||||||||
scalar · Integer32 (-180..180) · read-write · current A part of the systems global positioning data. The range +-180degrees Longitude lines are imaginary lines running from the north pole to the south pole. Longitudes are usually (WGS84) referenced from Greenwich, England where it has been established as Zero Degrees longitude. Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemLongitudeDecimal | 1.3.6.1.4.1.12148.10.2.11 | Integer32 | RW | 0 | |||||||||||||||||
scalar · Integer32 · read-write · current The decimal part of dcSystemLatitude contains up to 7digits. This number is in 1/1000000 degree fractions or 0,0000001 degree. A part of the systems global positioning data. Longitude lines are imaginary lines running from the north pole to the south pole. Longitudes are usually (WGS84) referenced from Greenwich, England where it has been established as Zero Degrees longitude. Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemLatitude | 1.3.6.1.4.1.12148.10.2.12 | Integer32 (-90..90) | RW | 0 | |||||||||||||||||
scalar · Integer32 (-90..90) · read-write · current A part of the systems global positioning data. The latitude gives the location of a place on Earth (or other planetary body) north or south of the equator. Lines of Latitude has a range of +-90 degrees and are the imaginary horizontal lines shown running east-to-west (or west to east). Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemLatitudeDecimal | 1.3.6.1.4.1.12148.10.2.13 | Integer32 | RW | 0 | |||||||||||||||||
scalar · Integer32 · read-write · current The decimal part of dcSystemLatitude contains up to 7digits. This number is in 1/1000000 degree fractions or 0,0000001 degree. A part of the systems global positioning data. Lines of Latitude has a range of +-90 degrees and are the imaginary horizontal lines shown running east-to-west (or west to east). Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this. Longitude lines are imaginary lines running from the north pole to the south pole. Longitudes are usually (WGS84) referenced from Greenwich, England where it has been established as Zero Degrees longitude. Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemElevation | 1.3.6.1.4.1.12148.10.2.14 | Integer32 | RW | 0 | |||||||||||||||||
scalar · Integer32 · read-write · current A part of the systems global positioning data. This is the sites height above sealevel in Meters. The Elevation together with Latituse and Longitude is used for automagically placing system icons on NMS/Sitemonitors system that support this. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemCurrentDecimalSetting | 1.3.6.1.4.1.12148.10.2.15 | INTEGER | RW | deciAmpere(1) | |||||||||||||||||
scalar · INTEGER · read-write · current A global flag telling if the current values in the system is Amperes or DeciAmpres
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemTemperatureScale | 1.3.6.1.4.1.12148.10.2.16 | INTEGER | RW | celcius(0) | |||||||||||||||||
scalar · INTEGER · read-write · current A flag telling if the temperatures values in the system is of Celcius or Fahrenheit type
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SpowerSystemCapacityScale | 1.3.6.1.4.1.12148.10.2.17 | INTEGER | RW | ah(0) | |||||||||||||||||
scalar · INTEGER · read-write · current A flag telling if the system's battery capacity value is a percentage of a fully charged battery, or in AmpereHours
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nmains | 1.3.6.1.4.1.12148.10.3 | ||||||||||||||||||||
| SmainsStatus | 1.3.6.1.4.1.12148.10.3.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The overall status of mains/AC feed subsystem.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NmainsMainsFailure | 1.3.6.1.4.1.12148.10.3.2 | ||||||||||||||||||||
| SmainsMainsFailureStatus | 1.3.6.1.4.1.12148.10.3.2.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed phases is higher than the defined alarm level.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsMainsFailureDescription | 1.3.6.1.4.1.12148.10.3.2.2 | DisplayString (SIZE (0..16)) | RW | MainsLow | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the mains phase failure monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsMainsFailureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.3.2.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SmainsMainsFailureAlarmEnable | 1.3.6.1.4.1.12148.10.3.2.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsMainsFailureValue | 1.3.6.1.4.1.12148.10.3.2.5 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed phases. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsMainsFailureMajorAlarmLevel | 1.3.6.1.4.1.12148.10.3.2.6 | Integer32 | RW | 2 | |||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsMainsFailureMinorAlarmLevel | 1.3.6.1.4.1.12148.10.3.2.7 | Integer32 | RW | 1 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsNumberOfPhases | 1.3.6.1.4.1.12148.10.3.3 | Integer32 | RW | 1 | |||||||||||||||||
scalar · Integer32 · read-write · current This value showing the number of phases of the mains subsystem. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsVoltageTable | 1.3.6.1.4.1.12148.10.3.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about mains voltage monitor | |||||||||||||||||||||
| RmainsVoltageEntry | 1.3.6.1.4.1.12148.10.3.4.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainsVoltageIndex | 1.3.6.1.4.1.12148.10.3.4.1.1 | Integer32 (1..12) | NA | ||||||||||||||||||
column · Integer32 (1..12) · not-accessible · current Index used for navigating the rows 1..12 of mainsVoltageTable | |||||||||||||||||||||
| CmainsVoltageStatus | 1.3.6.1.4.1.12148.10.3.4.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of the measured mains voltage.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsVoltageDescription | 1.3.6.1.4.1.12148.10.3.4.1.3 | DisplayString (SIZE (0..16)) | RW | MainsVolt 1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the mains voltage monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CmainsVoltageTrapRepeatCounter | 1.3.6.1.4.1.12148.10.3.4.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CmainsVoltageAlarmEnable | 1.3.6.1.4.1.12148.10.3.4.1.5 | INTEGER | RW | enabled(1) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsVoltageValue | 1.3.6.1.4.1.12148.10.3.4.1.6 | Integer32 | RO | 228 | |||||||||||||||||
| CmainsVoltageMajorHighLevel | 1.3.6.1.4.1.12148.10.3.4.1.7 | Integer32 | RW | 280 | |||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsVoltageMinorHighLevel | 1.3.6.1.4.1.12148.10.3.4.1.8 | Integer32 | RW | 260 | |||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsVoltageMinorLowLevel | 1.3.6.1.4.1.12148.10.3.4.1.9 | Integer32 | RW | 100 | |||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsVoltageMajorLowLevel | 1.3.6.1.4.1.12148.10.3.4.1.10 | Integer32 | RW | 80 | |||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NmainsMonitors | 1.3.6.1.4.1.12148.10.3.5 | ||||||||||||||||||||
| SmainsMonitorsNumberOfUnits | 1.3.6.1.4.1.12148.10.3.5.1 | Integer32 (0..14) | RW | 0 | |||||||||||||||||
scalar · Integer32 (0..14) · read-write · current This is the number of AC Mains Monitor CAN Nodes installed in the system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsMonitorsTable | 1.3.6.1.4.1.12148.10.3.5.2 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the number of voltage, current and frequency measurements in each AC Mains Monitor | |||||||||||||||||||||
| RmainsMonitorsEntry | 1.3.6.1.4.1.12148.10.3.5.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainsMonitorIndex | 1.3.6.1.4.1.12148.10.3.5.2.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of mainsMonitorsTable The size of the table is defined by the system | |||||||||||||||||||||
| CmainsMonitorNumberOfVoltages | 1.3.6.1.4.1.12148.10.3.5.2.1.2 | Integer32 (0..3) | RO | 3 | |||||||||||||||||
column · Integer32 (0..3) · read-only · current The number of voltage measurements in the AC Mains Monitor Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorNumberOfCurrents | 1.3.6.1.4.1.12148.10.3.5.2.1.3 | Integer32 (0..3) | RO | 3 | |||||||||||||||||
column · Integer32 (0..3) · read-only · current The number of current measurements in the AC Mains Monitor Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorNumberOfFrequencies | 1.3.6.1.4.1.12148.10.3.5.2.1.4 | Integer32 (0..3) | RO | 1 | |||||||||||||||||
column · Integer32 (0..3) · read-only · current The number of frequency measurements in the AC Mains Monitor Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsMonitorVoltageTable | 1.3.6.1.4.1.12148.10.3.5.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about mains voltage in AC Mains Monitor | |||||||||||||||||||||
| RmainsMonitorVoltageEntry | 1.3.6.1.4.1.12148.10.3.5.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsMonitorPhaseIndex | 1.3.6.1.4.1.12148.10.3.5.3.1.1 | Integer32 (1..3) | NA | ||||||||||||||||||
column · Integer32 (1..3) · not-accessible · current Index used for navigating the rows 1..3 of mainsMonitorVolatgeTable | |||||||||||||||||||||
| CmainsMonitorVoltageStatus | 1.3.6.1.4.1.12148.10.3.5.3.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured mains voltage in AC Mains Monitor.
| |||||||||||||||||||||
| CmainsMonitorVoltageDescription | 1.3.6.1.4.1.12148.10.3.5.3.1.3 | DisplayString (SIZE (1..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-write · current A textual description of the mains voltage in AC Mains Monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CmainsMonitorVoltageTrapRepeatCounter | 1.3.6.1.4.1.12148.10.3.5.3.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CmainsMonitorVoltageAlarmEnable | 1.3.6.1.4.1.12148.10.3.5.3.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CmainsMonitorVoltageValue | 1.3.6.1.4.1.12148.10.3.5.3.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured mains voltage in AC Mains Monitor. | |||||||||||||||||||||
| CmainsMonitorVoltageMajorHighLevel | 1.3.6.1.4.1.12148.10.3.5.3.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CmainsMonitorVoltageMinorHighLevel | 1.3.6.1.4.1.12148.10.3.5.3.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CmainsMonitorVoltageMinorLowLevel | 1.3.6.1.4.1.12148.10.3.5.3.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CmainsMonitorVoltageMajorLowLevel | 1.3.6.1.4.1.12148.10.3.5.3.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| TmainsMonitorCurrentTable | 1.3.6.1.4.1.12148.10.3.5.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about mains current in AC Mains Monitor | |||||||||||||||||||||
| RmainsMonitorCurrentEntry | 1.3.6.1.4.1.12148.10.3.5.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsMonitorCurrentStatus | 1.3.6.1.4.1.12148.10.3.5.4.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured mains current in AC Mains Monitor.
| |||||||||||||||||||||
| CmainsMonitorCurrentDescription | 1.3.6.1.4.1.12148.10.3.5.4.1.2 | DisplayString (SIZE (1..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-write · current A textual description of the mains current in AC Mains Monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CmainsMonitorCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.3.5.4.1.3 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CmainsMonitorCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.3.5.4.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CmainsMonitorCurrentValue | 1.3.6.1.4.1.12148.10.3.5.4.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured mains current in AC Mains Monitor. | |||||||||||||||||||||
| CmainsMonitorCurrentMajorHighLevel | 1.3.6.1.4.1.12148.10.3.5.4.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CmainsMonitorCurrentMinorHighLevel | 1.3.6.1.4.1.12148.10.3.5.4.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| TmainsMonitorFrequencyTable | 1.3.6.1.4.1.12148.10.3.5.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about mains frequency in AC Mains Monitor | |||||||||||||||||||||
| RmainsMonitorFrequencyEntry | 1.3.6.1.4.1.12148.10.3.5.5.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainsMonitorFrequencyStatus | 1.3.6.1.4.1.12148.10.3.5.5.1.1 | INTEGER | RO | error(0) | |||||||||||||||||
column · INTEGER · read-only · current The status of the measured mains frequency in AC Mains Monitor.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorFrequencyDescription | 1.3.6.1.4.1.12148.10.3.5.5.1.2 | DisplayString (SIZE (0..16)) | RW | | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the mains frequency in AC Mains Monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorFrequencyTrapRepeatCounter | 1.3.6.1.4.1.12148.10.3.5.5.1.3 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CmainsMonitorFrequencyAlarmEnable | 1.3.6.1.4.1.12148.10.3.5.5.1.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorFrequencyValue | 1.3.6.1.4.1.12148.10.3.5.5.1.5 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current The value of the measured mains frequency in AC Mains Monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorFrequencyMajorHighLevel | 1.3.6.1.4.1.12148.10.3.5.5.1.6 | Integer32 | RW | 0 | |||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorFrequencyMinorHighLevel | 1.3.6.1.4.1.12148.10.3.5.5.1.7 | Integer32 | RW | 0 | |||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorFrequencyMinorLowLevel | 1.3.6.1.4.1.12148.10.3.5.5.1.8 | Integer32 | RW | 0 | |||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmainsMonitorFrequencyMajorLowLevel | 1.3.6.1.4.1.12148.10.3.5.5.1.9 | Integer32 | RW | 0 | |||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsMonitorEnergyLogAccumulatedTable | 1.3.6.1.4.1.12148.10.3.5.6 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the accumulated energy consumption measured in AC Mains Monitor | |||||||||||||||||||||
| RmainsMonitorEnergyLogAccumulatedEntry | 1.3.6.1.4.1.12148.10.3.5.6.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainsMonitorEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.3.5.6.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The accumulated energy consumption value | |||||||||||||||||||||
| SmainsMonitorEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.3.5.7 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in hourly energy log Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsMonitorEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.3.5.8 | NA | |||||||||||||||||||
table · not-accessible · current This table contains energy consumption values logged every hour in AC Mains Monitor. | |||||||||||||||||||||
| RmainsMonitorEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.3.5.8.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsMonitorEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.3.5.8.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsMonitorEnergyLogLastHoursTable | |||||||||||||||||||||
| CmainsMonitorEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.3.5.8.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy consumption value logged every hour in AC Mains Monitor. | |||||||||||||||||||||
| SmainsMonitorEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.3.5.9 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in daily energy log Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsMonitorEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.3.5.10 | NA | |||||||||||||||||||
table · not-accessible · current This table contains energy consumption values logged every day in AC Mains Monitor. | |||||||||||||||||||||
| RmainsMonitorEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.3.5.10.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsMonitorEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.3.5.10.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsMonitorEnergyLogLastDaysTable | |||||||||||||||||||||
| CmainsMonitorEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.3.5.10.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy consumption value logged every day in AC Mains Monitor. | |||||||||||||||||||||
| SmainsMonitorEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.3.5.11 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in weekly energy log Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsMonitorEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.3.5.12 | NA | |||||||||||||||||||
table · not-accessible · current This table contains energy consumption values logged every week in AC Mains Monitor. | |||||||||||||||||||||
| RmainsMonitorEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.3.5.12.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsMonitorEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.3.5.12.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsMonitorEnergyLogLastWeeksTable | |||||||||||||||||||||
| CmainsMonitorEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.3.5.12.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy consumption value logged every week in AC Mains Monitor. | |||||||||||||||||||||
| NmainsOutageLog | 1.3.6.1.4.1.12148.10.3.6 | ||||||||||||||||||||
| SmainsOutageTotal | 1.3.6.1.4.1.12148.10.3.6.1 | Integer32 | RO | 8 | |||||||||||||||||
scalar · Integer32 · read-only · current This is the total mains outage time measured in hours. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsOutageLogDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.3.6.2 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in daily mains outage log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsOutageLogDaysTable | 1.3.6.1.4.1.12148.10.3.6.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily mains outage time log. | |||||||||||||||||||||
| RmainsOutageLogDaysEntry | 1.3.6.1.4.1.12148.10.3.6.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsOutageLogDaysIndex | 1.3.6.1.4.1.12148.10.3.6.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsOutageLogDaysTable | |||||||||||||||||||||
| CmainsOutageLogDaysValue | 1.3.6.1.4.1.12148.10.3.6.3.1.2 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Mains outage time value in minutes, logged every day. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsOutageLogWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.3.6.4 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in weekly mains outage time log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsOutageLogWeeksTable | 1.3.6.1.4.1.12148.10.3.6.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly mains outage time log. | |||||||||||||||||||||
| RmainsOutageLogWeeksEntry | 1.3.6.1.4.1.12148.10.3.6.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsOutageLogWeeksIndex | 1.3.6.1.4.1.12148.10.3.6.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsOutageLogWeeksTable | |||||||||||||||||||||
| CmainsOutageLogWeeksValue | 1.3.6.1.4.1.12148.10.3.6.5.1.2 | Integer32 | RO | 0 | |||||||||||||||||
| SmainsOutageLogMonthsNumberOfEntries | 1.3.6.1.4.1.12148.10.3.6.6 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in monthly mains outage time log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsOutageLogMonthsTable | 1.3.6.1.4.1.12148.10.3.6.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains monthly mains outage time log. | |||||||||||||||||||||
| RmainsOutageLogMonthsEntry | 1.3.6.1.4.1.12148.10.3.6.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsOutageLogMonthsIndex | 1.3.6.1.4.1.12148.10.3.6.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsOutageLogMonthsTable | |||||||||||||||||||||
| CmainsOutageLogMonthsValue | 1.3.6.1.4.1.12148.10.3.6.7.1.2 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Mains outage time value in hours, logged every month. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmainsNumberOfGroups | 1.3.6.1.4.1.12148.10.3.7 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current This value showing the number of groups of the mains subsystem. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmainsGroupsTable | 1.3.6.1.4.1.12148.10.3.8 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the status of mains group and number of phases in each group. | |||||||||||||||||||||
| RmainsGroupsEntry | 1.3.6.1.4.1.12148.10.3.8.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainsGroupIndex | 1.3.6.1.4.1.12148.10.3.8.1.1 | Integer32 (1..10) | NA | ||||||||||||||||||
column · Integer32 (1..10) · not-accessible · current Index used for navigating the rows 1..10 of mainsGroupTable | |||||||||||||||||||||
| CmainsGroupStatus | 1.3.6.1.4.1.12148.10.3.8.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of mains group.
| |||||||||||||||||||||
| CmainsGroupNumberOfPhases | 1.3.6.1.4.1.12148.10.3.8.1.3 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current This value showing the number of phases of the mains group subsystem. | |||||||||||||||||||||
| TmainsGroupMainsFailureTable | 1.3.6.1.4.1.12148.10.3.9 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about mains failure monitor of mains group | |||||||||||||||||||||
| RmainsGroupMainsFailureEntry | 1.3.6.1.4.1.12148.10.3.9.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainsGroupMainsFailureStatus | 1.3.6.1.4.1.12148.10.3.9.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This status value shows if the number of failed phases is higher than the defined alarm level for the mains group
| |||||||||||||||||||||
| CmainsGroupMainsFailureDescription | 1.3.6.1.4.1.12148.10.3.9.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the mains group phase failure monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CmainsGroupMainsFailureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.3.9.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CmainsGroupMainsFailureAlarmEnable | 1.3.6.1.4.1.12148.10.3.9.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CmainsGroupMainsFailureValue | 1.3.6.1.4.1.12148.10.3.9.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The detected number of failed phases in the mains group. | |||||||||||||||||||||
| CmainsGroupMainsFailureMajorAlarmLevel | 1.3.6.1.4.1.12148.10.3.9.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CmainsGroupMainsFailureMinorAlarmLevel | 1.3.6.1.4.1.12148.10.3.9.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TmainsGroupVoltageTable | 1.3.6.1.4.1.12148.10.3.10 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about mains voltage monitors for mains group | |||||||||||||||||||||
| RmainsGroupVoltageEntry | 1.3.6.1.4.1.12148.10.3.10.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsGroupVoltageIndex | 1.3.6.1.4.1.12148.10.3.10.1.1 | Integer32 (1..12) | NA | ||||||||||||||||||
column · Integer32 (1..12) · not-accessible · current Index used for navigating the rows 1..12 of mainsGroupVoltageTable | |||||||||||||||||||||
| CmainsGroupVoltageStatus | 1.3.6.1.4.1.12148.10.3.10.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured mains voltage of the mains group.
| |||||||||||||||||||||
| CmainsGroupVoltageDescription | 1.3.6.1.4.1.12148.10.3.10.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the mains voltage monitor of the mains group. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CmainsGroupVoltageTrapRepeatCounter | 1.3.6.1.4.1.12148.10.3.10.1.4 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CmainsGroupVoltageAlarmEnable | 1.3.6.1.4.1.12148.10.3.10.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CmainsGroupVoltageValue | 1.3.6.1.4.1.12148.10.3.10.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured mains voltage in the mains group. | |||||||||||||||||||||
| CmainsGroupVoltageMajorHighLevel | 1.3.6.1.4.1.12148.10.3.10.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CmainsGroupVoltageMinorHighLevel | 1.3.6.1.4.1.12148.10.3.10.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CmainsGroupVoltageMinorLowLevel | 1.3.6.1.4.1.12148.10.3.10.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CmainsGroupVoltageMajorLowLevel | 1.3.6.1.4.1.12148.10.3.10.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| TmainsGroupOutageLogTable | 1.3.6.1.4.1.12148.10.3.11 | NA | |||||||||||||||||||
table · not-accessible · current This table contains total mains outage of the mains group and number of entries in each log table. | |||||||||||||||||||||
| RmainsGroupOutageLogEntry | 1.3.6.1.4.1.12148.10.3.11.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainsGroupOutageTotal | 1.3.6.1.4.1.12148.10.3.11.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the total mains outage time measured in hours in the mains group. | |||||||||||||||||||||
| CmainsGroupOutageLogDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.3.11.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in daily mains outage log. | |||||||||||||||||||||
| CmainsGroupOutageLogWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.3.11.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in weekly mains outage time log. | |||||||||||||||||||||
| CmainsGroupOutageLogMonthsNumberOfEntries | 1.3.6.1.4.1.12148.10.3.11.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in monthly mains outage time log. | |||||||||||||||||||||
| TmainsGroupOutageLogDaysTable | 1.3.6.1.4.1.12148.10.3.12 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily mains outage time log of mains group. | |||||||||||||||||||||
| RmainsGroupOutageLogDaysEntry | 1.3.6.1.4.1.12148.10.3.12.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsGroupOutageLogDaysIndex | 1.3.6.1.4.1.12148.10.3.12.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsGroupOutageLogDaysTable | |||||||||||||||||||||
| CmainsGroupOutageLogDaysValue | 1.3.6.1.4.1.12148.10.3.12.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Mains outage time value in minutes of each mains group, logged every day. | |||||||||||||||||||||
| TmainsGroupOutageLogWeeksTable | 1.3.6.1.4.1.12148.10.3.13 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly mains outage time log of mains group. | |||||||||||||||||||||
| RmainsGroupOutageLogWeeksEntry | 1.3.6.1.4.1.12148.10.3.13.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsGroupOutageLogWeeksIndex | 1.3.6.1.4.1.12148.10.3.13.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsGroupOutageLogWeeksTable | |||||||||||||||||||||
| CmainsGroupOutageLogWeeksValue | 1.3.6.1.4.1.12148.10.3.13.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Mains outage time value in hours of each mains group, logged every week. | |||||||||||||||||||||
| TmainsGroupOutageLogMonthsTable | 1.3.6.1.4.1.12148.10.3.14 | NA | |||||||||||||||||||
table · not-accessible · current This table contains monthly mains outage time log of mains group. | |||||||||||||||||||||
| RmainsGroupOutageLogMonthsEntry | 1.3.6.1.4.1.12148.10.3.14.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainsGroupOutageLogMonthsIndex | 1.3.6.1.4.1.12148.10.3.14.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of mainsGroupOutageLogMonthsTable | |||||||||||||||||||||
| CmainsGroupOutageLogMonthsValue | 1.3.6.1.4.1.12148.10.3.14.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Mains outage time value in hours of each mains group, logged every month. | |||||||||||||||||||||
| Ngenerator | 1.3.6.1.4.1.12148.10.4 | ||||||||||||||||||||
| SgeneratorStatus | 1.3.6.1.4.1.12148.10.4.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The overall status of generator subsystem.
| |||||||||||||||||||||
| SgeneratorFailStatus | 1.3.6.1.4.1.12148.10.4.2 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of generator failure monitor.
| |||||||||||||||||||||
| SgeneratorActivation | 1.3.6.1.4.1.12148.10.4.3 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Indicate if the generator run output signal is activated. | |||||||||||||||||||||
| SgeneratorDischargeValue | 1.3.6.1.4.1.12148.10.4.4 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the present discharge value in percentage of total capacity. | |||||||||||||||||||||
| SgeneratorMainsDelay | 1.3.6.1.4.1.12148.10.4.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Elapsing time of mains failure. | |||||||||||||||||||||
| SgeneratorChargeTime | 1.3.6.1.4.1.12148.10.4.6 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Elapsing time of charging with generator running. | |||||||||||||||||||||
| SgeneratorCapacityControlledStartStopEnable | 1.3.6.1.4.1.12148.10.4.7 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Battery charge/discharge level control of starting and stopping of generator
| |||||||||||||||||||||
| SgeneratorCapacityStartOnDischargeLimit | 1.3.6.1.4.1.12148.10.4.8 | Integer32 (0..100) | RW | ||||||||||||||||||
scalar · Integer32 (0..100) · read-write · current When the generatorCapacityControlled is enabled, the generator is started when the remaining battery capacity drops below this limit in percentage of the total capacity. | |||||||||||||||||||||
| SgeneratorCapacityStopOnChargeLimit | 1.3.6.1.4.1.12148.10.4.9 | Integer32 (0..100) | RW | ||||||||||||||||||
scalar · Integer32 (0..100) · read-write · current When the generatorCapacityControlled is enabled, the generator is stopped when the remaining battery capacity is greater than this limit in percentage of the total capacity. | |||||||||||||||||||||
| SgeneratorCurrentLimitControlledStopEnable | 1.3.6.1.4.1.12148.10.4.10 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enables the generator to stop when the charge current drops below generatorCurrentLimitControlledStopValue.
| |||||||||||||||||||||
| SgeneratorCurrentLimitControlledStopValue | 1.3.6.1.4.1.12148.10.4.11 | Integer32 (0..100) | RW | ||||||||||||||||||
scalar · Integer32 (0..100) · read-write · current Generator stops when the charge current drop drops below this level. | |||||||||||||||||||||
| SgeneratorVoltageControlledStartEnable | 1.3.6.1.4.1.12148.10.4.12 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable voltage controlled generator activation.
| |||||||||||||||||||||
| SgeneratorVoltageControlStartVoltage | 1.3.6.1.4.1.12148.10.4.13 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The voltage limit to start generator. | |||||||||||||||||||||
| SgeneratorVoltageControlStopAfter | 1.3.6.1.4.1.12148.10.4.14 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current A time delay for stopping generator when generator is activated by voltage. | |||||||||||||||||||||
| SgeneratorDailyRunEnable | 1.3.6.1.4.1.12148.10.4.15 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable generator daily run function.
| |||||||||||||||||||||
| TgeneratorDailyRunSetupTable | 1.3.6.1.4.1.12148.10.4.16 | NA | |||||||||||||||||||
table · not-accessible · current This table contains configurations of generator daily run. | |||||||||||||||||||||
| RgeneratorDailyRunSetupEntry | 1.3.6.1.4.1.12148.10.4.16.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorDailyRunDayIndex | 1.3.6.1.4.1.12148.10.4.16.1.1 | INTEGER | NA | ||||||||||||||||||
column · INTEGER · not-accessible · current Index used for navigating the rows 1..7 of generatorDailyRunSetupTable
| |||||||||||||||||||||
| CgeneratorDailyRunStartHour | 1.3.6.1.4.1.12148.10.4.16.1.2 | Integer32 (0..23) | RW | ||||||||||||||||||
column · Integer32 (0..23) · read-write · current Generator daily starting time. | |||||||||||||||||||||
| CgeneratorDailyRunStopHour | 1.3.6.1.4.1.12148.10.4.16.1.3 | Integer32 (0..23) | RW | ||||||||||||||||||
column · Integer32 (0..23) · read-write · current Generator daily stopping time. | |||||||||||||||||||||
| SgeneratorMonthlyRunEnable | 1.3.6.1.4.1.12148.10.4.17 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable generator monthly run function.
| |||||||||||||||||||||
| SgeneratorMonthlyRunStartTime | 1.3.6.1.4.1.12148.10.4.18 | Integer32 (0..23) | RW | ||||||||||||||||||
scalar · Integer32 (0..23) · read-write · current Generator monthly run starting time. | |||||||||||||||||||||
| SgeneratorMonthlyRunStartDayinMonth1 | 1.3.6.1.4.1.12148.10.4.19 | Integer32 (1..32) | RW | ||||||||||||||||||
scalar · Integer32 (1..32) · read-write · current Generator monthly run starting day #1. | |||||||||||||||||||||
| SgeneratorMonthlyRunStartDayinMonth2 | 1.3.6.1.4.1.12148.10.4.20 | Integer32 (1..32) | RW | ||||||||||||||||||
scalar · Integer32 (1..32) · read-write · current Generator monthly run starting day #2. | |||||||||||||||||||||
| SgeneratorTankNumberOfTanks | 1.3.6.1.4.1.12148.10.4.21 | Integer32 (0..2) | RO | ||||||||||||||||||
scalar · Integer32 (0..2) · read-only · current Number of fuel tanks. | |||||||||||||||||||||
| TgeneratorTankTable | 1.3.6.1.4.1.12148.10.4.22 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about generator fuel tanks. | |||||||||||||||||||||
| RgeneratorTankEntry | 1.3.6.1.4.1.12148.10.4.22.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CgeneratorTankIndex | 1.3.6.1.4.1.12148.10.4.22.1.1 | Integer32 (1..2) | NA | ||||||||||||||||||
column · Integer32 (1..2) · not-accessible · current Index used for navigating the rows 1..2 of generatorTankTable | |||||||||||||||||||||
| CgeneratorTankStatus | 1.3.6.1.4.1.12148.10.4.22.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured fuel level in tank.
| |||||||||||||||||||||
| CgeneratorTankDescription | 1.3.6.1.4.1.12148.10.4.22.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the fuel level monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CgeneratorTankTrapRepeatCounter | 1.3.6.1.4.1.12148.10.4.22.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CgeneratorTankEnable | 1.3.6.1.4.1.12148.10.4.22.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CgeneratorTankValue | 1.3.6.1.4.1.12148.10.4.22.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured fuel level. | |||||||||||||||||||||
| CgeneratorTankMajorHighLevel | 1.3.6.1.4.1.12148.10.4.22.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CgeneratorTankMinorHighLevel | 1.3.6.1.4.1.12148.10.4.22.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CgeneratorTankMinorLowLevel | 1.3.6.1.4.1.12148.10.4.22.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CgeneratorTankMajorLowLevel | 1.3.6.1.4.1.12148.10.4.22.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| NgeneratorEnergyLog | 1.3.6.1.4.1.12148.10.4.23 | ||||||||||||||||||||
| SgeneratorEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.4.23.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered through rectifiers from generator. | |||||||||||||||||||||
| SgeneratorEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.4.23.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator hourly energy log. | |||||||||||||||||||||
| TgeneratorEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.4.23.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of generator. | |||||||||||||||||||||
| RgeneratorEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.4.23.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.4.23.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorEnergyLogLastHoursTable | |||||||||||||||||||||
| CgeneratorEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.4.23.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. | |||||||||||||||||||||
| SgeneratorEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.4.23.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator daily energy log. | |||||||||||||||||||||
| TgeneratorEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.4.23.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of generator. | |||||||||||||||||||||
| RgeneratorEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.4.23.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.4.23.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorEnergyLogLastDaysTable | |||||||||||||||||||||
| CgeneratorEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.4.23.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day | |||||||||||||||||||||
| SgeneratorEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.4.23.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator weekly energy log. | |||||||||||||||||||||
| TgeneratorEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.4.23.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of generator. | |||||||||||||||||||||
| RgeneratorEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.4.23.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.4.23.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorEnergyLogLastWeeksTable | |||||||||||||||||||||
| CgeneratorEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.4.23.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every week. | |||||||||||||||||||||
| NgeneratorRunHoursLog | 1.3.6.1.4.1.12148.10.4.24 | ||||||||||||||||||||
| SgeneratorRunHoursTotalHours | 1.3.6.1.4.1.12148.10.4.24.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the total generator running hours. | |||||||||||||||||||||
| SgeneratorRunHoursLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.4.24.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator daily running hours log. | |||||||||||||||||||||
| TgeneratorRunHoursLogLastDaysTable | 1.3.6.1.4.1.12148.10.4.24.3 | NA | |||||||||||||||||||
table · not-accessible · current generator running time in minutes | |||||||||||||||||||||
| RgeneratorRunHoursLogLastDaysEntry | 1.3.6.1.4.1.12148.10.4.24.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorRunHoursLogLastDaysIndex | 1.3.6.1.4.1.12148.10.4.24.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorRunHoursLogLastDaysTable | |||||||||||||||||||||
| CgeneratorRunHoursLogLastDaysValue | 1.3.6.1.4.1.12148.10.4.24.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Generator running time in minutes, logged every day. | |||||||||||||||||||||
| SgeneratorRunHoursLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.4.24.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator weekly running hours log. | |||||||||||||||||||||
| TgeneratorRunHoursLogLastWeeksTable | 1.3.6.1.4.1.12148.10.4.24.5 | NA | |||||||||||||||||||
table · not-accessible · current generator running time in hours | |||||||||||||||||||||
| RgeneratorRunHoursLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.4.24.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorRunHoursLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.4.24.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorRunHoursLogLastWeeksTable | |||||||||||||||||||||
| CgeneratorRunHoursLogLastWeeksValue | 1.3.6.1.4.1.12148.10.4.24.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Generator running time in hours, logged every week. | |||||||||||||||||||||
| SgeneratorRunHoursLogLastMonthsNumberOfEntries | 1.3.6.1.4.1.12148.10.4.24.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator monthly running hours log. | |||||||||||||||||||||
| TgeneratorRunHoursLogLastMonthsTable | 1.3.6.1.4.1.12148.10.4.24.7 | NA | |||||||||||||||||||
table · not-accessible · current generator running time in hours | |||||||||||||||||||||
| RgeneratorRunHoursLogLastMonthsEntry | 1.3.6.1.4.1.12148.10.4.24.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorRunHoursLogLastMonthsIndex | 1.3.6.1.4.1.12148.10.4.24.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorRunHoursLogLastMonthsTable | |||||||||||||||||||||
| CgeneratorRunHoursLogLastMonthsValue | 1.3.6.1.4.1.12148.10.4.24.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Generator running time in hours, logged every month. | |||||||||||||||||||||
| NgeneratorFuelConsumptionLog | 1.3.6.1.4.1.12148.10.4.25 | ||||||||||||||||||||
| TgeneratorFuelConsumptionTotalUsedTable | 1.3.6.1.4.1.12148.10.4.25.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains total fuel consumption for each tank. | |||||||||||||||||||||
| RgeneratorFuelConsumptionTotalUsedEntry | 1.3.6.1.4.1.12148.10.4.25.1.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CgeneratorFuelConsumptionTotalUsed | 1.3.6.1.4.1.12148.10.4.25.1.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Total fuel consumption value. | |||||||||||||||||||||
| SgeneratorFuelConsumptionLogLastDaysNoOfEntries | 1.3.6.1.4.1.12148.10.4.25.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator daily fuel consumption log. | |||||||||||||||||||||
| TgeneratorFuelConsumptionLogLastDaysTable | 1.3.6.1.4.1.12148.10.4.25.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains generator daily fuel consumption log. | |||||||||||||||||||||
| RgeneratorFuelConsumptionLogLastDaysEntry | 1.3.6.1.4.1.12148.10.4.25.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorFuelConsumptionLogLastDaysIndex | 1.3.6.1.4.1.12148.10.4.25.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorFuelConsumptionLogLastDaysTable | |||||||||||||||||||||
| CgeneratorFuelConsumptionLogLastDaysValue | 1.3.6.1.4.1.12148.10.4.25.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Generator fuel consumption value, logged every day. | |||||||||||||||||||||
| SgeneratorFuelConsumptionLogLastWeeksNoOfEntries | 1.3.6.1.4.1.12148.10.4.25.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator weekly fuel consumption log. | |||||||||||||||||||||
| TgeneratorFuelConsumptionLogLastWeeksTable | 1.3.6.1.4.1.12148.10.4.25.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains generator weekly fuel consumption log. | |||||||||||||||||||||
| RgeneratorFuelConsumptionLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.4.25.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorFuelConsumptionLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.4.25.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorFuelConsumptionLogLastWeeksTable | |||||||||||||||||||||
| CgeneratorFuelConsumptionLogLastWeeksValue | 1.3.6.1.4.1.12148.10.4.25.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Generator fuel consumption value, logged every week. | |||||||||||||||||||||
| SgeneratorFuelConsumptionLogLastMonthsNoOfEntries | 1.3.6.1.4.1.12148.10.4.25.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in generator hourly fuel consumption log. | |||||||||||||||||||||
| TgeneratorFuelConsumptionLogLastMonthsTable | 1.3.6.1.4.1.12148.10.4.25.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains generator hourly fuel consumption log. | |||||||||||||||||||||
| RgeneratorFuelConsumptionLogLastMonthsEntry | 1.3.6.1.4.1.12148.10.4.25.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CgeneratorFuelConsumptionLogLastMonthsIndex | 1.3.6.1.4.1.12148.10.4.25.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of generatorFuelConsumptionLogLastHoursTable | |||||||||||||||||||||
| CgeneratorFuelConsumptionLogLastMonthsValue | 1.3.6.1.4.1.12148.10.4.25.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Generator fuel consumption value, logged every hour. | |||||||||||||||||||||
| Nrectifiers | 1.3.6.1.4.1.12148.10.5 | ||||||||||||||||||||
| SrectifiersStatus | 1.3.6.1.4.1.12148.10.5.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The overall status of rectifier subsystem.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NrectifiersCurrent | 1.3.6.1.4.1.12148.10.5.2 | ||||||||||||||||||||
| SrectifiersCurrentStatus | 1.3.6.1.4.1.12148.10.5.2.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured total rectifier current.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCurrentDescription | 1.3.6.1.4.1.12148.10.5.2.2 | DisplayString (SIZE (0..16)) | RW | Rect.current | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the total rectifier current monitor. This is stored in the system controller and can be changed by the user Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.2.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SrectifiersCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.5.2.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCurrentValue | 1.3.6.1.4.1.12148.10.5.2.5 | Integer32 | RO | 63 | |||||||||||||||||
scalar · Integer32 · read-only · current The value of the measured total rectifier current. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.5.2.6 | Integer32 | RW | 5000 | |||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.5.2.7 | Integer32 | RW | 4000 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NrectifiersCapacity | 1.3.6.1.4.1.12148.10.5.3 | ||||||||||||||||||||
| SrectifiersCapacityStatus | 1.3.6.1.4.1.12148.10.5.3.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured used rectifier capacity.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCapacityDescription | 1.3.6.1.4.1.12148.10.5.3.2 | DisplayString (SIZE (0..16)) | RW | Rect.capacity | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the used rectifier capacity monitor. This is stored in the system controller and can be changed by the user Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.3.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SrectifiersCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.5.3.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCapacityValue | 1.3.6.1.4.1.12148.10.5.3.5 | Integer32 | RO | 6 | |||||||||||||||||
scalar · Integer32 · read-only · current The used rectifier capacity value presented in percentage of the total installed rectifier capacity. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCapacityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.5.3.6 | Integer32 | RW | 95 | |||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersCapacityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.5.3.7 | Integer32 | RW | 90 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NrectifiersError | 1.3.6.1.4.1.12148.10.5.4 | ||||||||||||||||||||
| SrectifiersErrorStatus | 1.3.6.1.4.1.12148.10.5.4.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed units is higher than the defined alarm level.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersErrorDescription | 1.3.6.1.4.1.12148.10.5.4.2 | DisplayString (SIZE (0..16)) | RW | Rect.error | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the rectifier error monitor. This is stored in the system controller and can be changed by the user Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.4.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SrectifiersErrorEnable | 1.3.6.1.4.1.12148.10.5.4.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersErrorValue | 1.3.6.1.4.1.12148.10.5.4.5 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current The number of failed rectifiers. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.5.4.6 | Integer32 | RW | 2 | |||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.5.4.7 | Integer32 | RW | 1 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersNumberOfRectifiers | 1.3.6.1.4.1.12148.10.5.5 | Integer32 (0..100) | RW | 3 | |||||||||||||||||
scalar · Integer32 (0..100) · read-write · current Number of installed rectifiers. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TrectifierTable | 1.3.6.1.4.1.12148.10.5.6 | NA | |||||||||||||||||||
table · not-accessible · current This table shows the information of each rectifier installed in the system. | |||||||||||||||||||||
| RrectifierEntry | 1.3.6.1.4.1.12148.10.5.6.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CrectifierIndex | 1.3.6.1.4.1.12148.10.5.6.1.1 | Integer32 (1..100) | NA | ||||||||||||||||||
column · Integer32 (1..100) · not-accessible · current Index used for navigating the rows 1..100 of rectifierTable | |||||||||||||||||||||
| CrectifierStatus | 1.3.6.1.4.1.12148.10.5.6.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The overall status of rectifier.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrectifierOutputCurrentValue | 1.3.6.1.4.1.12148.10.5.6.1.3 | Integer32 | RO | 31 | |||||||||||||||||
| CrectifierInputVoltageValue | 1.3.6.1.4.1.12148.10.5.6.1.4 | Integer32 | RO | 227 | |||||||||||||||||
column · Integer32 · read-only · current The input voltage value of rectifier. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrectifierType | 1.3.6.1.4.1.12148.10.5.6.1.5 | DisplayString (SIZE (0..27)) | RO | Flatpack S 48/1000 | |||||||||||||||||
column · DisplayString (SIZE (0..27)) · read-only · current Type of rectifier Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrectifierHwPartNumber | 1.3.6.1.4.1.12148.10.5.6.1.6 | DisplayString (SIZE (0..12)) | RO | 241122.105 | |||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of rectifier Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrectifierHwVersion | 1.3.6.1.4.1.12148.10.5.6.1.7 | DisplayString (SIZE (0..6)) | RO | 2.81 | |||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Hardware version number of rectifier Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrectifierSwPartNumber | 1.3.6.1.4.1.12148.10.5.6.1.8 | DisplayString (SIZE (0..12)) | RO | 404210.009 | |||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Part number of secondary software in rectifier Example values from LibreNMS test devices
| |||||||||||||||||||||
| CrectifierSwVersion | 1.3.6.1.4.1.12148.10.5.6.1.9 | DisplayString (SIZE (0..6)) | RO | 2.01 | |||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Version number of secondary software in rectifier Example values from LibreNMS test devices
| |||||||||||||||||||||
| NrectifiersEnergyLog | 1.3.6.1.4.1.12148.10.5.7 | ||||||||||||||||||||
| SrectifiersEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.5.7.1 | Integer32 | RO | 7819858 | |||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered from rectifiers. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.5.7.2 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in rectifier hourly energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TrectifiersEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.5.7.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of rectifiers. | |||||||||||||||||||||
| RrectifiersEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.5.7.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CrectifiersEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.5.7.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of rectifiersEnergyLogLastHoursTable | |||||||||||||||||||||
| CrectifiersEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.5.7.3.1.2 | Integer32 | RO | 418 | |||||||||||||||||
| SrectifiersEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.5.7.4 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in rectifier daily energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TrectifiersEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.5.7.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of rectifiers. | |||||||||||||||||||||
| RrectifiersEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.5.7.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CrectifiersEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.5.7.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of rectifiersEnergyLogLastDaysTable | |||||||||||||||||||||
| CrectifiersEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.5.7.5.1.2 | Integer32 | RO | 10 | |||||||||||||||||
| SrectifiersEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.5.7.6 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in rectifier weekly energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TrectifiersEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.5.7.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of rectifiers. | |||||||||||||||||||||
| RrectifiersEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.5.7.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CrectifiersEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.5.7.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of rectifiersEnergyLogLastWeekTable | |||||||||||||||||||||
| CrectifiersEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.5.7.7.1.2 | Integer32 | RO | 70 | |||||||||||||||||
| SrectifiersNumberOfGroups | 1.3.6.1.4.1.12148.10.5.8 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current Number of rectifier groups Example values from LibreNMS test devices
| |||||||||||||||||||||
| TrectifierGroupsTable | 1.3.6.1.4.1.12148.10.5.9 | NA | |||||||||||||||||||
table · not-accessible · current This table contains status and the number of installed rectifiers of each rectifier groups. | |||||||||||||||||||||
| RrectifierGroupsEntry | 1.3.6.1.4.1.12148.10.5.9.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CrectifierGroupIndex | 1.3.6.1.4.1.12148.10.5.9.1.1 | Integer32 (1..10) | NA | ||||||||||||||||||
column · Integer32 (1..10) · not-accessible · current Index used for navigating the rows 1..10 of rectifierGroupsTable | |||||||||||||||||||||
| CrectifierGroupStatus | 1.3.6.1.4.1.12148.10.5.9.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of each rectifier group.
| |||||||||||||||||||||
| CrectifierGroupNumberOfRectifiers | 1.3.6.1.4.1.12148.10.5.9.1.3 | Integer32 (0..100) | RW | ||||||||||||||||||
column · Integer32 (0..100) · read-write · current Number of installed rectifiers in each rectifier groups | |||||||||||||||||||||
| TrectifierGroupCurrentTable | 1.3.6.1.4.1.12148.10.5.10 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the total rectifier current of each rectifier groups, which is calculated by summing up current from each rectifier in a rectifier group. | |||||||||||||||||||||
| RrectifierGroupCurrentEntry | 1.3.6.1.4.1.12148.10.5.10.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CrectifierGroupCurrentStatus | 1.3.6.1.4.1.12148.10.5.10.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured total rectifier current of the rectifier group
| |||||||||||||||||||||
| CrectifierGroupCurrentDescription | 1.3.6.1.4.1.12148.10.5.10.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the total rectifier current monitor of a rectifier group. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CrectifierGroupCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.10.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CrectifierGroupCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.5.10.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CrectifierGroupCurrentValue | 1.3.6.1.4.1.12148.10.5.10.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured total rectifier current of each rectifier group. | |||||||||||||||||||||
| CrectifierGroupCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.5.10.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CrectifierGroupCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.5.10.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TrectifierGroupCapacityTable | 1.3.6.1.4.1.12148.10.5.11 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the used rectifier capacity of each rectifier group. | |||||||||||||||||||||
| RrectifierGroupCapacityEntry | 1.3.6.1.4.1.12148.10.5.11.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CrectifierGroupCapacityStatus | 1.3.6.1.4.1.12148.10.5.11.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured used rectifier capacity of each rectifier group
| |||||||||||||||||||||
| CrectifierGroupCapacityDescription | 1.3.6.1.4.1.12148.10.5.11.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the used rectifier capacity monitor of each rectifier group. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CrectifierGroupCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.11.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CrectifierGroupCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.5.11.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CrectifierGroupCapacityValue | 1.3.6.1.4.1.12148.10.5.11.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The used rectifier capacity value presented in percentage of the total installed rectifier capacity of each rectifier group. | |||||||||||||||||||||
| CrectifierGroupCapacityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.5.11.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CrectifierGroupCapacityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.5.11.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TrectifierGroupErrorTable | 1.3.6.1.4.1.12148.10.5.12 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the rectifier error monitor of each rectifier group. | |||||||||||||||||||||
| RrectifierGroupErrorEntry | 1.3.6.1.4.1.12148.10.5.12.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CrectifierGroupErrorStatus | 1.3.6.1.4.1.12148.10.5.12.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This status value shows if the number of failed units is higher than the defined alarm level.
| |||||||||||||||||||||
| CrectifierGroupErrorDescription | 1.3.6.1.4.1.12148.10.5.12.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the rectifier error monitor of each rectifier group. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CrectifierGroupErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.12.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CrectifierGroupErrorAlarmEnable | 1.3.6.1.4.1.12148.10.5.12.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CrectifierGroupErrorValue | 1.3.6.1.4.1.12148.10.5.12.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of failed rectifiers of each rectifier group. | |||||||||||||||||||||
| CrectifierGroupErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.5.12.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CrectifierGroupErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.5.12.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TrectifierGroupRectifierTable | 1.3.6.1.4.1.12148.10.5.13 | NA | |||||||||||||||||||
table · not-accessible · current This table shows the information of each rectifier installed in each of the rectifier group in the system. | |||||||||||||||||||||
| RrectifierGroupRectifierEntry | 1.3.6.1.4.1.12148.10.5.13.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CrectifierGroupRectifierIndex | 1.3.6.1.4.1.12148.10.5.13.1.1 | Integer32 (1..100) | NA | ||||||||||||||||||
column · Integer32 (1..100) · not-accessible · current Index used for navigating the rows 1..100 of rectifierGroupRectifierTable | |||||||||||||||||||||
| CrectifierGroupRectifierStatus | 1.3.6.1.4.1.12148.10.5.13.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of rectifier.
| |||||||||||||||||||||
| CrectifierGroupRectifierOutputCurrentValue | 1.3.6.1.4.1.12148.10.5.13.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output current value of rectifier. | |||||||||||||||||||||
| CrectifierGroupRectifierInputVoltageValue | 1.3.6.1.4.1.12148.10.5.13.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The input voltage value of rectifier. | |||||||||||||||||||||
| CrectifierGroupRectifierType | 1.3.6.1.4.1.12148.10.5.13.1.5 | DisplayString (SIZE (0..27)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..27)) · read-only · current Type of rectifier | |||||||||||||||||||||
| CrectifierGroupRectifierHwPartNumber | 1.3.6.1.4.1.12148.10.5.13.1.6 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of rectifier | |||||||||||||||||||||
| CrectifierGroupRectifierHwVersion | 1.3.6.1.4.1.12148.10.5.13.1.7 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Hardware version number of rectifier | |||||||||||||||||||||
| CrectifierGroupRectifierSwPartNumber | 1.3.6.1.4.1.12148.10.5.13.1.8 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Part number of secondary software in rectifier | |||||||||||||||||||||
| CrectifierGroupRectifierSwVersion | 1.3.6.1.4.1.12148.10.5.13.1.9 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Version number of secondary software in rectifier | |||||||||||||||||||||
| TrectifierGroupEnergyLogTable | 1.3.6.1.4.1.12148.10.5.14 | NA | |||||||||||||||||||
table · not-accessible · current This branch contains information about rectifiers' energy logs of each rectifier group. | |||||||||||||||||||||
| RrectifierGroupEnergyLogEntry | 1.3.6.1.4.1.12148.10.5.14.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CrectifierGroupEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.5.14.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the accumulated energy delivered from rectifiers of each rectifier group. | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.5.14.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in rectifier group hourly energy log. | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.5.14.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in rectifier group daily energy log. | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.5.14.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in rectifier group weekly energy log. | |||||||||||||||||||||
| TrectifierGroupEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.5.15 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of each rectifier group | |||||||||||||||||||||
| RrectifierGroupEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.5.15.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.5.15.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of rectifierGroupEnergyLogLastHoursTable | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.5.15.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. | |||||||||||||||||||||
| TrectifierGroupEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.5.16 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of each rectifier group | |||||||||||||||||||||
| RrectifierGroupEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.5.16.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.5.16.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of rectifierGroupEnergyLogLasDaysTable | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.5.16.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. | |||||||||||||||||||||
| TrectifierGroupEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.5.17 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of each rectifier group | |||||||||||||||||||||
| RrectifierGroupEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.5.17.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.5.17.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of rectifierGroupEnergyLogLastWeeksTable | |||||||||||||||||||||
| CrectifierGroupEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.5.17.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every week. | |||||||||||||||||||||
| NrectifiersTemperature | 1.3.6.1.4.1.12148.10.5.18 | ||||||||||||||||||||
| SrectifiersTemperatureStatus | 1.3.6.1.4.1.12148.10.5.18.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The state of the rectifier temperature can be either one of the defined enumerated values
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersTemperatureDescription | 1.3.6.1.4.1.12148.10.5.18.2 | DisplayString (SIZE (0..16)) | RW | Rect.temp | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the rectifier temperature monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.18.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SrectifiersTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.5.18.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersTemperatureValue | 1.3.6.1.4.1.12148.10.5.18.5 | Integer32 (0..9999) | RO | 34 | |||||||||||||||||
scalar · Integer32 (0..9999) · read-only · current The highest value of the rectifier temperature measurements. Depending on the global setting in the Control unit, this value will be presented in Celsius or Fahrenheit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.5.18.6 | Integer32 | RW | 80 | |||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.5.18.7 | Integer32 | RW | 70 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.5.18.8 | Integer32 | RW | -5 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SrectifiersTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.5.18.9 | Integer32 | RW | -10 | |||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| TrectifierGroupTemperatureTable | 1.3.6.1.4.1.12148.10.5.19 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the highest rectifier temperature of each rectifier groups, which is calculated by summing up current from each rectifier in a rectifier group. | |||||||||||||||||||||
| RrectifierGroupTemperatureEntry | 1.3.6.1.4.1.12148.10.5.19.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CrectifierGroupTemperatureStatus | 1.3.6.1.4.1.12148.10.5.19.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured highest rectifier temperature of the rectifier group
| |||||||||||||||||||||
| CrectifierGroupTemperatureDescription | 1.3.6.1.4.1.12148.10.5.19.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the highest rectifier temperature monitor of a rectifier group. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CrectifierGroupTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.5.19.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CrectifierGroupTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.5.19.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CrectifierGroupTemperatureValue | 1.3.6.1.4.1.12148.10.5.19.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured highest rectifier temperature of each rectifier group. | |||||||||||||||||||||
| CrectifierGroupTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.5.19.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CrectifierGroupTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.5.19.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CrectifierGroupTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.5.19.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CrectifierGroupTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.5.19.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| Ndcdc | 1.3.6.1.4.1.12148.10.6 | ||||||||||||||||||||
| SdcdcNumberOfGroups | 1.3.6.1.4.1.12148.10.6.1 | Integer32 (0..5) | RO | ||||||||||||||||||
scalar · Integer32 (0..5) · read-only · current Number of dcdc groups | |||||||||||||||||||||
| TdcdcGroupsTable | 1.3.6.1.4.1.12148.10.6.2 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about dcdc groups. | |||||||||||||||||||||
| RdcdcGroupsEntry | 1.3.6.1.4.1.12148.10.6.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CdcdcGroupIndex | 1.3.6.1.4.1.12148.10.6.2.1.1 | Integer32 (1..5) | NA | ||||||||||||||||||
| CdcdcGroupStatus | 1.3.6.1.4.1.12148.10.6.2.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of dcdc group.
| |||||||||||||||||||||
| CdcdcGroupNumberOfDcdcConverters | 1.3.6.1.4.1.12148.10.6.2.1.3 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Number of installed dcdc converters. | |||||||||||||||||||||
| CdcdcGroupOutputVoltage | 1.3.6.1.4.1.12148.10.6.2.1.4 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Output voltage of dcdc converters | |||||||||||||||||||||
| CdcdcNumberOfCurrents | 1.3.6.1.4.1.12148.10.6.2.1.5 | Integer32 (0..5) | RO | ||||||||||||||||||
column · Integer32 (0..5) · read-only · current Number of dcdc currents | |||||||||||||||||||||
| CdcdcNumberOfCapacities | 1.3.6.1.4.1.12148.10.6.2.1.6 | Integer32 (0..5) | RO | ||||||||||||||||||
column · Integer32 (0..5) · read-only · current Number of dcdc capacities | |||||||||||||||||||||
| CdcdcNumberOfAlarms | 1.3.6.1.4.1.12148.10.6.2.1.7 | Integer32 (0..5) | RO | ||||||||||||||||||
column · Integer32 (0..5) · read-only · current Number of dcdc alarms | |||||||||||||||||||||
| TdcdcCurrentTable | 1.3.6.1.4.1.12148.10.6.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the total dcdc current. | |||||||||||||||||||||
| RdcdcCurrentEntry | 1.3.6.1.4.1.12148.10.6.3.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CdcdcCurrentStatus | 1.3.6.1.4.1.12148.10.6.3.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured total dcdc current.
| |||||||||||||||||||||
| CdcdcCurrentDescription | 1.3.6.1.4.1.12148.10.6.3.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the total dcdc current monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CdcdcCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.6.3.1.3 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CdcdcCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.6.3.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CdcdcCurrentValue | 1.3.6.1.4.1.12148.10.6.3.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured total dcdc current. | |||||||||||||||||||||
| CdcdcCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.6.3.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CdcdcCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.6.3.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TdcdcCapacityTable | 1.3.6.1.4.1.12148.10.6.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the used dcdc capacity. | |||||||||||||||||||||
| RdcdcCapacityEntry | 1.3.6.1.4.1.12148.10.6.4.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CdcdcCapacityStatus | 1.3.6.1.4.1.12148.10.6.4.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured used dcdc capacity.
| |||||||||||||||||||||
| CdcdcCapacityDescription | 1.3.6.1.4.1.12148.10.6.4.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the used dcdc capacity monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CdcdcCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.6.4.1.3 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes of | |||||||||||||||||||||
| CdcdcCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.6.4.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CdcdcCapacityValue | 1.3.6.1.4.1.12148.10.6.4.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The used dcdc capacity value presented in percentage of the total installed dcdc capacity. | |||||||||||||||||||||
| CdcdcCapacityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.6.4.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CdcdcCapacityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.6.4.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TdcdcTable | 1.3.6.1.4.1.12148.10.6.5 | NA | |||||||||||||||||||
table · not-accessible · current This table shows the information of each dcdc converter installed in the system. | |||||||||||||||||||||
| RdcdcEntry | 1.3.6.1.4.1.12148.10.6.5.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CdcdcIndex | 1.3.6.1.4.1.12148.10.6.5.1.1 | Integer32 (1..100) | NA | ||||||||||||||||||
column · Integer32 (1..100) · not-accessible · current Index used for navigating the rows 1..100 of dcdcTable | |||||||||||||||||||||
| CdcdcStatus | 1.3.6.1.4.1.12148.10.6.5.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of dcdc converter
| |||||||||||||||||||||
| CdcdcOutputCurrentValue | 1.3.6.1.4.1.12148.10.6.5.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output current value of dcdc. | |||||||||||||||||||||
| CdcdcInputVoltageValue | 1.3.6.1.4.1.12148.10.6.5.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The input voltage value of dcdc. | |||||||||||||||||||||
| CdcdcType | 1.3.6.1.4.1.12148.10.6.5.1.5 | DisplayString (SIZE (0..27)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..27)) · read-only · current Type of dcdc converter | |||||||||||||||||||||
| CdcdcHwPartNumber | 1.3.6.1.4.1.12148.10.6.5.1.6 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of dcdc converter | |||||||||||||||||||||
| CdcdcHwVersion | 1.3.6.1.4.1.12148.10.6.5.1.7 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Hardware version number of dcdc converter | |||||||||||||||||||||
| CdcdcSwPartNumber | 1.3.6.1.4.1.12148.10.6.5.1.8 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Part number of secondary software in dcdc converter | |||||||||||||||||||||
| CdcdcSwVersion | 1.3.6.1.4.1.12148.10.6.5.1.9 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Version number of secondary software in dcdc converter | |||||||||||||||||||||
| TdcdcErrorTable | 1.3.6.1.4.1.12148.10.6.6 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the dcdc error monitor. | |||||||||||||||||||||
| RdcdcErrorEntry | 1.3.6.1.4.1.12148.10.6.6.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CdcdcErrorStatus | 1.3.6.1.4.1.12148.10.6.6.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This status value shows if the number of failed units is higher than the defined alarm level.
| |||||||||||||||||||||
| CdcdcErrorDescription | 1.3.6.1.4.1.12148.10.6.6.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the dcdc error monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CdcdcErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.6.6.1.3 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CdcdcErrorEnable | 1.3.6.1.4.1.12148.10.6.6.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CdcdcErrorValue | 1.3.6.1.4.1.12148.10.6.6.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of failed dcdc converters. | |||||||||||||||||||||
| CdcdcErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.6.6.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CdcdcErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.6.6.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NdcdcObsolete | 1.3.6.1.4.1.12148.10.6.7 | ||||||||||||||||||||
| NsolarChargers | 1.3.6.1.4.1.12148.10.7 | ||||||||||||||||||||
| SsolarChargersStatus | 1.3.6.1.4.1.12148.10.7.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The overall status of solar charger subsystem.
| |||||||||||||||||||||
| NsolarChargersCurrent | 1.3.6.1.4.1.12148.10.7.2 | ||||||||||||||||||||
| SsolarChargersCurrentStatus | 1.3.6.1.4.1.12148.10.7.2.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured total solar current.
| |||||||||||||||||||||
| SsolarChargersCurrentDescription | 1.3.6.1.4.1.12148.10.7.2.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the total solar current monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SsolarChargersCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.7.2.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SsolarChargersCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.7.2.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SsolarChargersCurrentValue | 1.3.6.1.4.1.12148.10.7.2.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The value of the measured total solar current. | |||||||||||||||||||||
| SsolarChargersCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.7.2.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SsolarChargersCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.7.2.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NsolarChargersObsolete | 1.3.6.1.4.1.12148.10.7.3 | ||||||||||||||||||||
| NsolarChargersError | 1.3.6.1.4.1.12148.10.7.4 | ||||||||||||||||||||
| SsolarChargersErrorStatus | 1.3.6.1.4.1.12148.10.7.4.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed units is higher than the defined alarm level.
| |||||||||||||||||||||
| SsolarChargersErrorDescription | 1.3.6.1.4.1.12148.10.7.4.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the solar error monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SsolarChargersErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.7.4.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SsolarChargersErrorEnable | 1.3.6.1.4.1.12148.10.7.4.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SsolarChargersErrorValue | 1.3.6.1.4.1.12148.10.7.4.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The number of failed solar chargers. | |||||||||||||||||||||
| SsolarChargersErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.7.4.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SsolarChargersErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.7.4.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| SsolarChargersNumberOfSolarChargers | 1.3.6.1.4.1.12148.10.7.5 | Integer32 (0..100) | RW | ||||||||||||||||||
scalar · Integer32 (0..100) · read-write · current Number of installed solar chargers. | |||||||||||||||||||||
| TsolarChargerTable | 1.3.6.1.4.1.12148.10.7.6 | NA | |||||||||||||||||||
table · not-accessible · current This table shows the information of each solar charger installed in the system. | |||||||||||||||||||||
| RsolarChargerEntry | 1.3.6.1.4.1.12148.10.7.6.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CsolarChargerIndex | 1.3.6.1.4.1.12148.10.7.6.1.1 | Integer32 (1..100) | NA | ||||||||||||||||||
column · Integer32 (1..100) · not-accessible · current Index used for navigating the rows 1..100 of solarChargerTable | |||||||||||||||||||||
| CsolarChargerStatus | 1.3.6.1.4.1.12148.10.7.6.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of solar charger.
| |||||||||||||||||||||
| CsolarChargerOutputCurrentValue | 1.3.6.1.4.1.12148.10.7.6.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output current value of solar charger. | |||||||||||||||||||||
| CsolarChargerInputVoltageValue | 1.3.6.1.4.1.12148.10.7.6.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The input voltage value of solar charger. | |||||||||||||||||||||
| CsolarChargerType | 1.3.6.1.4.1.12148.10.7.6.1.5 | DisplayString (SIZE (0..27)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..27)) · read-only · current Type of solar charger | |||||||||||||||||||||
| CsolarChargerHwPartNumber | 1.3.6.1.4.1.12148.10.7.6.1.6 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of solar charger | |||||||||||||||||||||
| CsolarChargerHwVersion | 1.3.6.1.4.1.12148.10.7.6.1.7 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Hardware version number of solar charger | |||||||||||||||||||||
| CsolarChargerSwPartNumber | 1.3.6.1.4.1.12148.10.7.6.1.8 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Part number of secondary software in solar charger | |||||||||||||||||||||
| CsolarChargerSwVersion | 1.3.6.1.4.1.12148.10.7.6.1.9 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Version number of secondary software in solar charger | |||||||||||||||||||||
| NsolarChargersEnergyLog | 1.3.6.1.4.1.12148.10.7.7 | ||||||||||||||||||||
| SsolarChargersEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.7.7.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered from solar chargers. | |||||||||||||||||||||
| SsolarChargersEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.7.7.2 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the maximal number of entries stored in solar charger hourly energy log. | |||||||||||||||||||||
| TsolarChargersEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.7.7.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of solar chargers. | |||||||||||||||||||||
| RsolarChargersEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.7.7.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CsolarChargersEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.7.7.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of solarChargersEnergyLogLastHoursTable | |||||||||||||||||||||
| CsolarChargersEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.7.7.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. | |||||||||||||||||||||
| SsolarChargersEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.7.7.4 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the maximal number of entries stored in solar charger daily energy log. | |||||||||||||||||||||
| TsolarChargersEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.7.7.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of solar chargers. | |||||||||||||||||||||
| RsolarChargersEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.7.7.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CsolarChargersEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.7.7.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of solarChargersEnergyLogLastDaysTable | |||||||||||||||||||||
| CsolarChargersEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.7.7.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. | |||||||||||||||||||||
| SsolarChargersEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.7.7.6 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the maximal number of entries stored in solar charger weekly energy log. | |||||||||||||||||||||
| TsolarChargersEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.7.7.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of solar chargers. | |||||||||||||||||||||
| RsolarChargersEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.7.7.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CsolarChargersEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.7.7.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of solarChargersEnergyLogLastWeekTable | |||||||||||||||||||||
| CsolarChargersEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.7.7.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every week. | |||||||||||||||||||||
| NwindChargers | 1.3.6.1.4.1.12148.10.8 | ||||||||||||||||||||
| SwindChargersStatus | 1.3.6.1.4.1.12148.10.8.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The overall status of wind charger subsystem.
| |||||||||||||||||||||
| NwindChargersCurrent | 1.3.6.1.4.1.12148.10.8.2 | ||||||||||||||||||||
| SwindChargersCurrentStatus | 1.3.6.1.4.1.12148.10.8.2.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured total wind current.
| |||||||||||||||||||||
| SwindChargersCurrentDescription | 1.3.6.1.4.1.12148.10.8.2.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the total wind current monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SwindChargersCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.8.2.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SwindChargersCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.8.2.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SwindChargersCurrentValue | 1.3.6.1.4.1.12148.10.8.2.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The value of the measured total wind current. | |||||||||||||||||||||
| SwindChargersCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.8.2.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SwindChargersCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.8.2.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NwindChargersObsolete | 1.3.6.1.4.1.12148.10.8.3 | ||||||||||||||||||||
| NwindChargersError | 1.3.6.1.4.1.12148.10.8.4 | ||||||||||||||||||||
| SwindChargersErrorStatus | 1.3.6.1.4.1.12148.10.8.4.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed units is higher than the defined alarm level.
| |||||||||||||||||||||
| SwindChargersErrorDescription | 1.3.6.1.4.1.12148.10.8.4.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the wind error monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SwindChargersErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.8.4.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SwindChargersErrorEnable | 1.3.6.1.4.1.12148.10.8.4.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SwindChargersErrorValue | 1.3.6.1.4.1.12148.10.8.4.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The number of failed wind chargers. | |||||||||||||||||||||
| SwindChargersErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.8.4.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SwindChargersErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.8.4.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| SwindChargersNumberOfWindChargers | 1.3.6.1.4.1.12148.10.8.5 | Integer32 (0..254) | RW | ||||||||||||||||||
scalar · Integer32 (0..254) · read-write · current Number of installed wind chargers. | |||||||||||||||||||||
| TwindChargerTable | 1.3.6.1.4.1.12148.10.8.6 | NA | |||||||||||||||||||
table · not-accessible · current This table shows the information of each wind charger installed in the system. | |||||||||||||||||||||
| RwindChargerEntry | 1.3.6.1.4.1.12148.10.8.6.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CwindChargerIndex | 1.3.6.1.4.1.12148.10.8.6.1.1 | Integer32 (1..100) | NA | ||||||||||||||||||
column · Integer32 (1..100) · not-accessible · current Index used for navigating the rows 1..100 of windChargerTable | |||||||||||||||||||||
| CwindChargerStatus | 1.3.6.1.4.1.12148.10.8.6.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of wind charger.
| |||||||||||||||||||||
| CwindChargerOutputCurrentValue | 1.3.6.1.4.1.12148.10.8.6.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output current value of wind charger. | |||||||||||||||||||||
| CwindChargerInputVoltageValue | 1.3.6.1.4.1.12148.10.8.6.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The input voltage value of wind charger. | |||||||||||||||||||||
| CwindChargerType | 1.3.6.1.4.1.12148.10.8.6.1.5 | DisplayString (SIZE (0..27)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..27)) · read-only · current Type of wind charger | |||||||||||||||||||||
| CwindChargerHwPartNumber | 1.3.6.1.4.1.12148.10.8.6.1.6 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of wind charger | |||||||||||||||||||||
| CwindChargerHwVersion | 1.3.6.1.4.1.12148.10.8.6.1.7 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Hardware version number of wind charger | |||||||||||||||||||||
| CwindChargerSwPartNumber | 1.3.6.1.4.1.12148.10.8.6.1.8 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Part number of secondary software in wind charger | |||||||||||||||||||||
| CwindChargerSwVersion | 1.3.6.1.4.1.12148.10.8.6.1.9 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Version number of secondary software in wind charger | |||||||||||||||||||||
| NwindChargersEnergyLog | 1.3.6.1.4.1.12148.10.8.7 | ||||||||||||||||||||
| SwindChargersEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.8.7.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered to/from wind chargers. | |||||||||||||||||||||
| SwindChargersEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.8.7.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in wind charger hourly energy log. | |||||||||||||||||||||
| TwindChargersEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.8.7.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of wind chargers. | |||||||||||||||||||||
| RwindChargersEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.8.7.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CwindChargersEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.8.7.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of windChargersEnergyLogLastHoursTable | |||||||||||||||||||||
| CwindChargersEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.8.7.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. | |||||||||||||||||||||
| SwindChargersEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.8.7.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in wind charger daily energy log. | |||||||||||||||||||||
| TwindChargersEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.8.7.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of wind chargers. | |||||||||||||||||||||
| RwindChargersEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.8.7.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CwindChargersEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.8.7.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of windChargersEnergyLogLastDaysTable | |||||||||||||||||||||
| CwindChargersEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.8.7.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. | |||||||||||||||||||||
| SwindChargersEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.8.7.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in wind charger weekly energy log. | |||||||||||||||||||||
| TwindChargersEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.8.7.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of wind chargers. | |||||||||||||||||||||
| RwindChargersEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.8.7.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CwindChargersEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.8.7.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of windChargersEnergyLogLastWeekTable | |||||||||||||||||||||
| CwindChargersEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.8.7.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every week. | |||||||||||||||||||||
| Nload | 1.3.6.1.4.1.12148.10.9 | ||||||||||||||||||||
| SloadStatus | 1.3.6.1.4.1.12148.10.9.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The overall status of load subsystem.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NloadCurrent | 1.3.6.1.4.1.12148.10.9.2 | ||||||||||||||||||||
| SloadCurrentStatus | 1.3.6.1.4.1.12148.10.9.2.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured load current.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadCurrentDescription | 1.3.6.1.4.1.12148.10.9.2.2 | DisplayString (SIZE (0..16)) | RW | LoadCurrent | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the load current monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.9.2.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SloadCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.9.2.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadCurrentValue | 1.3.6.1.4.1.12148.10.9.2.5 | Integer32 | RO | 51 | |||||||||||||||||
scalar · Integer32 · read-only · current The value of the measured load current. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadCurrentMajorHighLevel | 1.3.6.1.4.1.12148.10.9.2.6 | Integer32 | RW | 32000 | |||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadCurrentMinorHighLevel | 1.3.6.1.4.1.12148.10.9.2.7 | Integer32 | RW | 22000 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadFusesStatus | 1.3.6.1.4.1.12148.10.9.3 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The overall status of the load fuses.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadNumberOfGroups | 1.3.6.1.4.1.12148.10.9.4 | Integer32 (1..8) | RW | 1 | |||||||||||||||||
scalar · Integer32 (1..8) · read-write · current Number of load groups Example values from LibreNMS test devices
| |||||||||||||||||||||
| TloadGroupTable | 1.3.6.1.4.1.12148.10.9.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about load groups. | |||||||||||||||||||||
| RloadGroupEntry | 1.3.6.1.4.1.12148.10.9.5.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CloadGroupIndex | 1.3.6.1.4.1.12148.10.9.5.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current Index used for navigating the rows 1..8 of loadGroupTable | |||||||||||||||||||||
| CloadGroupStatus | 1.3.6.1.4.1.12148.10.9.5.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of load group
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadNumberOfLVLDs | 1.3.6.1.4.1.12148.10.9.5.1.3 | Integer32 (0..4) | RO | 1 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of LVLDs installed in load group Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadNumberOfVoltages | 1.3.6.1.4.1.12148.10.9.5.1.4 | Integer32 (0..4) | RO | 3 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of voltages in load group Example values from LibreNMS test devices
| |||||||||||||||||||||
| TloadLVLDTable | 1.3.6.1.4.1.12148.10.9.6 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about LVLDs | |||||||||||||||||||||
| RloadLVLDEntry | 1.3.6.1.4.1.12148.10.9.6.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CloadLVLDIndex | 1.3.6.1.4.1.12148.10.9.6.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current Index used for navigating the rows 1..8 of loadLVLDTable | |||||||||||||||||||||
| CloadLVLDStatus | 1.3.6.1.4.1.12148.10.9.6.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of LVLD
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadLVLDDescription | 1.3.6.1.4.1.12148.10.9.6.1.3 | DisplayString (SIZE (0..16)) | RW | LVLD 1.1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the LVLD. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadLVLDTrapRepeatCounter | 1.3.6.1.4.1.12148.10.9.6.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CloadLVLDEnable | 1.3.6.1.4.1.12148.10.9.6.1.5 | INTEGER | RW | enabled(1) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the LVLD will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadLVLDValue | 1.3.6.1.4.1.12148.10.9.6.1.6 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current The measured value of the LVLD. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadLVLDConnectVoltage | 1.3.6.1.4.1.12148.10.9.6.1.7 | Integer32 | RW | 4800 | |||||||||||||||||
column · Integer32 · read-write · current The load Contactor's Reconnect Voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadLVLDDisconnectVoltage | 1.3.6.1.4.1.12148.10.9.6.1.8 | Integer32 | RW | 4400 | |||||||||||||||||
column · Integer32 · read-write · current The load Contactor's Disconnect Voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| TloadFuseTable | 1.3.6.1.4.1.12148.10.9.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about load fuse | |||||||||||||||||||||
| RloadFuseEntry | 1.3.6.1.4.1.12148.10.9.7.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CloadFuseStatus | 1.3.6.1.4.1.12148.10.9.7.1.1 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of load fuse
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadFuseDescription | 1.3.6.1.4.1.12148.10.9.7.1.2 | DisplayString (SIZE (0..16)) | RW | LoadFuse 1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the load fuse monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadFuseTrapRepeatCounter | 1.3.6.1.4.1.12148.10.9.7.1.3 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CloadFuseAlarmEnable | 1.3.6.1.4.1.12148.10.9.7.1.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadFuseValue | 1.3.6.1.4.1.12148.10.9.7.1.5 | Integer32 | RW | 0 | |||||||||||||||||
column · Integer32 · read-write · current The measured value of the load fuse. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NloadEnergyLog | 1.3.6.1.4.1.12148.10.9.8 | ||||||||||||||||||||
| SloadEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.9.8.1 | Integer32 | RO | 1521052 | |||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered to load. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.9.8.2 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in load hourly energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TloadEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.9.8.3 | NA | |||||||||||||||||||
| RloadEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.9.8.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CloadEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.9.8.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of loadEnergyLogLastHoursTable | |||||||||||||||||||||
| CloadEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.9.8.3.1.2 | Integer32 | RO | 277 | |||||||||||||||||
| SloadEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.9.8.4 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in load daily energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TloadEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.9.8.5 | NA | |||||||||||||||||||
| RloadEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.9.8.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CloadEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.9.8.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of loadEnergyLogLastDaysTable | |||||||||||||||||||||
| CloadEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.9.8.5.1.2 | Integer32 | RO | 7 | |||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SloadEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.9.8.6 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in load weekly energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TloadEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.9.8.7 | NA | |||||||||||||||||||
| RloadEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.9.8.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CloadEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.9.8.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of loadEnergyLogLastWeekTable | |||||||||||||||||||||
| CloadEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.9.8.7.1.2 | Integer32 | RO | 47 | |||||||||||||||||
| TloadVoltageTable | 1.3.6.1.4.1.12148.10.9.9 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about voltages | |||||||||||||||||||||
| RloadVoltageEntry | 1.3.6.1.4.1.12148.10.9.9.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CloadVoltageIndex | 1.3.6.1.4.1.12148.10.9.9.1.1 | Integer32 (1..3) | NA | ||||||||||||||||||
column · Integer32 (1..3) · not-accessible · current Index used for navigating the rows 1..3 of loadVoltageTable | |||||||||||||||||||||
| CloadVoltageStatus | 1.3.6.1.4.1.12148.10.9.9.1.2 | INTEGER | RO | disabled(4) | |||||||||||||||||
column · INTEGER · read-only · current The status of voltage
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadVoltageDescription | 1.3.6.1.4.1.12148.10.9.9.1.3 | DisplayString (SIZE (0..16)) | RW | Drop diode 1.1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the voltage. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CloadVoltageTrapRepeatCounter | 1.3.6.1.4.1.12148.10.9.9.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CloadVoltageEnable | 1.3.6.1.4.1.12148.10.9.9.1.5 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the LVLD will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CloadVoltageValue | 1.3.6.1.4.1.12148.10.9.9.1.6 | Integer32 | RO | 5402 | |||||||||||||||||
column · Integer32 · read-only · current The measured value of the voltage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nbattery | 1.3.6.1.4.1.12148.10.10 | ||||||||||||||||||||
| SbatteryStatus | 1.3.6.1.4.1.12148.10.10.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current A toplevel status for the battery subsystem. The state of this reflects the status of all underlying statuses for the battery. Any change in one of the 'data monitors' in the battery subsystem will propagate up to this status indicator.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryDescription | 1.3.6.1.4.1.12148.10.10.2 | DisplayString (SIZE (0..32)) | RW | Eltek Std | |||||||||||||||||
scalar · DisplayString (SIZE (0..32)) · read-write · current A descriptive name of the battery installed in the system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryReferenceVoltage | 1.3.6.1.4.1.12148.10.10.3 | Integer32 (840..60417) | RW | 5400 | |||||||||||||||||
scalar · Integer32 (840..60417) · read-write · current The Voltage at which the DC System float charges. Acts as reference voltage when running temperature compensated charging. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryFusesStatus | 1.3.6.1.4.1.12148.10.10.4 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The state of the battery fuses/breakers can mainly be normal(1) or majorAlarm(3) and some other rarely used values .
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryVoltage | 1.3.6.1.4.1.12148.10.10.5 | ||||||||||||||||||||
| SbatteryVoltageStatus | 1.3.6.1.4.1.12148.10.10.5.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured battery voltage.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryVoltageDescription | 1.3.6.1.4.1.12148.10.10.5.2 | DisplayString (SIZE (0..16)) | RW | BatteryVoltage | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery voltage monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryVoltageTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.5.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryVoltageAlarmEnable | 1.3.6.1.4.1.12148.10.10.5.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
scalar · INTEGER · read-write · current The measured battery voltage alarm enable/disable control
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryVoltageValue | 1.3.6.1.4.1.12148.10.10.5.5 | Integer32 (0..7500) | RO | 5416 | |||||||||||||||||
scalar · Integer32 (0..7500) · read-only · current The value of the measured battery voltage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryVoltageMajorHighLevel | 1.3.6.1.4.1.12148.10.10.5.6 | Integer32 | RW | 5700 | |||||||||||||||||
scalar · Integer32 · read-write · current The Major High Battery Voltage alarm limit set voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryVoltageMinorHighLevel | 1.3.6.1.4.1.12148.10.10.5.7 | Integer32 | RW | 5680 | |||||||||||||||||
scalar · Integer32 · read-write · current The Minor High Battery Voltage alarm limit set voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryVoltageMinorLowLevel | 1.3.6.1.4.1.12148.10.10.5.8 | Integer32 | RW | 4800 | |||||||||||||||||
scalar · Integer32 · read-write · current The Minor Low Battery Voltage alarm limit set voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryVoltageMajorLowLevel | 1.3.6.1.4.1.12148.10.10.5.9 | Integer32 | RW | 4630 | |||||||||||||||||
scalar · Integer32 · read-write · current The Major Low Battery Voltage alarm limit set voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryCurrents | 1.3.6.1.4.1.12148.10.10.6 | ||||||||||||||||||||
| SbatteryCurrentsStatus | 1.3.6.1.4.1.12148.10.10.6.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured battery current
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCurrentsDescription | 1.3.6.1.4.1.12148.10.10.6.2 | DisplayString (SIZE (0..16)) | RW | BatteryCurrent | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery current monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCurrentsTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.6.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryCurrentsAlarmEnable | 1.3.6.1.4.1.12148.10.10.6.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCurrentsValue | 1.3.6.1.4.1.12148.10.10.6.5 | Integer32 | RO | -2 | |||||||||||||||||
scalar · Integer32 · read-only · current The measured total battery current. This is the sum of all the enabled shunt measurements in the system. Negative battery current indicates discharging of the batteries. Positive battery current indicates charging of the batteries. Note that the units measured may be i Amperes or in Deciamperes depending on global system settings Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCurrentsMajorHighLevel | 1.3.6.1.4.1.12148.10.10.6.6 | Integer32 | RW | 32000 | |||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCurrentsMinorHighLevel | 1.3.6.1.4.1.12148.10.10.6.7 | Integer32 | RW | 22000 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCurrentsMinorLowLevel | 1.3.6.1.4.1.12148.10.10.6.8 | Integer32 | RW | -22000 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCurrentsMajorLowLevel | 1.3.6.1.4.1.12148.10.10.6.9 | Integer32 | RW | -32000 | |||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryTemperatures | 1.3.6.1.4.1.12148.10.10.7 | ||||||||||||||||||||
| SbatteryTemperaturesStatus | 1.3.6.1.4.1.12148.10.10.7.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The state of the battery fuses/breakers can be either one of the defined enumerated values
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTemperaturesDescription | 1.3.6.1.4.1.12148.10.10.7.2 | DisplayString (SIZE (0..16)) | RW | BatteryTemp | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery temperature monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTemperaturesTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.7.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryTemperaturesAlarmEnable | 1.3.6.1.4.1.12148.10.10.7.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTemperaturesValue | 1.3.6.1.4.1.12148.10.10.7.5 | Integer32 (0..9999) | RO | 0 | |||||||||||||||||
scalar · Integer32 (0..9999) · read-only · current The highest value of the enabled battery temperature measurements. Depending on the global setting in the Control unit, this value will be presented in Celsius or Fahrenheit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTemperaturesMajorHighLevel | 1.3.6.1.4.1.12148.10.10.7.6 | Integer32 | RW | 40 | |||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTemperaturesMinorHighLevel | 1.3.6.1.4.1.12148.10.10.7.7 | Integer32 | RW | 30 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTemperaturesMinorLowLevel | 1.3.6.1.4.1.12148.10.10.7.8 | Integer32 | RW | -5 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTemperaturesMajorLowLevel | 1.3.6.1.4.1.12148.10.10.7.9 | Integer32 | RW | -10 | |||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryTimeLeft | 1.3.6.1.4.1.12148.10.10.8 | ||||||||||||||||||||
| SbatteryTimeLeftStatus | 1.3.6.1.4.1.12148.10.10.8.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the estimated battery remaining backup time.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTimeLeftDescription | 1.3.6.1.4.1.12148.10.10.8.2 | DisplayString (SIZE (0..16)) | RW | BatteryTimeLeft | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery discharge time monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTimeLeftTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.8.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryTimeLeftAlarmEnable | 1.3.6.1.4.1.12148.10.10.8.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTimeLeftValue | 1.3.6.1.4.1.12148.10.10.8.5 | Integer32 | RO | 356 | |||||||||||||||||
scalar · Integer32 · read-only · current The estimated value of battery remaining backup time. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTimeLeftMinorAlarmLevel | 1.3.6.1.4.1.12148.10.10.8.6 | Integer32 | RW | 25 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTimeLeftMajorAlarmLevel | 1.3.6.1.4.1.12148.10.10.8.7 | Integer32 | RW | 20 | |||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryRemainingCapacity | 1.3.6.1.4.1.12148.10.10.9 | ||||||||||||||||||||
| SbatteryRemainingCapacityStatus | 1.3.6.1.4.1.12148.10.10.9.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery remaining capacity monitor.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryRemainingCapacityDescription | 1.3.6.1.4.1.12148.10.10.9.2 | DisplayString (SIZE (0..16)) | RW | BatteryRemCap | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery remaining capacity monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryRemainingCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.9.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryRemainingCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.10.9.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryRemainingCapacityValue | 1.3.6.1.4.1.12148.10.10.9.5 | Integer32 | RO | 210 | |||||||||||||||||
scalar · Integer32 · read-only · current Battery remaining capacity (SOC) value estimated from the latest battery test result. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryRemainingCapacityMinorLowLevel | 1.3.6.1.4.1.12148.10.10.9.6 | Integer32 | RW | 52 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryRemainingCapacityMajorLowLevel | 1.3.6.1.4.1.12148.10.10.9.7 | Integer32 | RW | 42 | |||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryUsedCapacity | 1.3.6.1.4.1.12148.10.10.10 | ||||||||||||||||||||
| SbatteryUsedCapacityStatus | 1.3.6.1.4.1.12148.10.10.10.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery used capacity (DoD) monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryUsedCapacityDescription | 1.3.6.1.4.1.12148.10.10.10.2 | DisplayString (SIZE (0..16)) | RW | BatteryUsedCap | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery used capacity (DoD) monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryUsedCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.10.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryUsedCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.10.10.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryUsedCapacityValue | 1.3.6.1.4.1.12148.10.10.10.5 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current This is the estimated battery used capacity (DoD). Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryUsedCapacityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.10.10.6 | Integer32 | RW | 52 | |||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryUsedCapacityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.10.10.7 | Integer32 | RW | 42 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryTotalCapacity | 1.3.6.1.4.1.12148.10.10.11 | ||||||||||||||||||||
| SbatteryTotalCapacityStatus | 1.3.6.1.4.1.12148.10.10.11.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the total capacity monitor.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTotalCapacityDescription | 1.3.6.1.4.1.12148.10.10.11.2 | DisplayString (SIZE (0..16)) | RW | BatteryTotCap | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery total capacity monitor. This is stored in the system controller and can be changed by the user Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTotalCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.11.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryTotalCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.10.11.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTotalCapacityValue | 1.3.6.1.4.1.12148.10.10.11.5 | Integer32 | RO | 210 | |||||||||||||||||
scalar · Integer32 · read-only · current This is the estimated total battery capacity (installed Ah - SoH) value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTotalCapacityMinorLowLevel | 1.3.6.1.4.1.12148.10.10.11.6 | Integer32 | RW | 168 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTotalCapacityMajorLowLevel | 1.3.6.1.4.1.12148.10.10.11.7 | Integer32 | RW | 157 | |||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryQuality | 1.3.6.1.4.1.12148.10.10.12 | ||||||||||||||||||||
| SbatteryQualityStatus | 1.3.6.1.4.1.12148.10.10.12.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery quality (SoH) monitor.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryQualityDescription | 1.3.6.1.4.1.12148.10.10.12.2 | DisplayString (SIZE (0..16)) | RW | BatteryQuality | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery quality (SoH) monitor. This is stored in the system controller and can be changed by the user Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryQualityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.12.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryQualityAlarmEnable | 1.3.6.1.4.1.12148.10.10.12.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryQualityValue | 1.3.6.1.4.1.12148.10.10.12.5 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current The calculated battery quality (SoH) based on the latest battery test Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryQualityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.10.12.6 | Integer32 | RW | 80 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryQualityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.10.12.7 | Integer32 | RW | 75 | |||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryLVBD | 1.3.6.1.4.1.12148.10.10.13 | ||||||||||||||||||||
| SbatteryLVBDStatus | 1.3.6.1.4.1.12148.10.10.13.1 | INTEGER | RO | normal(1) | |||||||||||||||||
scalar · INTEGER · read-only · current The Battery Contactor is connected, disconnected, disabled or in any other alarm condition
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryLVBDDescription | 1.3.6.1.4.1.12148.10.10.13.2 | DisplayString (SIZE (0..16)) | RW | LVBD | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery LVBD monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryLVBDTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.13.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryLVBDEnable | 1.3.6.1.4.1.12148.10.10.13.4 | INTEGER | RW | enabled(1) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the LVBD will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryLVBDValue | 1.3.6.1.4.1.12148.10.10.13.5 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current The measured value of the LVBD. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryLVBDConnectVoltage | 1.3.6.1.4.1.12148.10.10.13.6 | Integer32 | RW | 5000 | |||||||||||||||||
scalar · Integer32 · read-write · current The Battery Contactor's Reconnect Voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryLVBDDisconnectVoltage | 1.3.6.1.4.1.12148.10.10.13.7 | Integer32 | RW | 4200 | |||||||||||||||||
scalar · Integer32 · read-write · current The Battery Contactor's Disconnect Voltage Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryChargeCurrentLimit | 1.3.6.1.4.1.12148.10.10.14 | ||||||||||||||||||||
| SbatteryChargeCurrentLimitEnable | 1.3.6.1.4.1.12148.10.10.14.1 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable of the battery charge current limitation feature; 0=disable, 1=enable.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryChargeCurrentLimitValue | 1.3.6.1.4.1.12148.10.10.14.2 | Integer32 (0..32767) | RW | 100 | |||||||||||||||||
scalar · Integer32 (0..32767) · read-write · current Battery charging current limit value. Used only when AC source is mains feed. Note that the units measured may be i Amperes or in Deciamperes depending on global system settings Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryBoost | 1.3.6.1.4.1.12148.10.10.15 | ||||||||||||||||||||
| SbatteryBoostVoltage | 1.3.6.1.4.1.12148.10.10.15.1 | Integer32 (870..60418) | RW | 5450 | |||||||||||||||||
scalar · Integer32 (870..60418) · read-write · current The Voltage at which the DC System boost charges the batteries. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryBoostCommand | 1.3.6.1.4.1.12148.10.10.15.2 | INTEGER | RW | pushbutton(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This pushbutton will start or stop a manual battery boost if the system allows it.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryBoostCurrentThreshold | 1.3.6.1.4.1.12148.10.10.15.3 | Integer32 | RW | 10 | |||||||||||||||||
scalar · Integer32 · read-write · current The boosting will terminate when the charge current drops below the BoostCurrentThreshold limit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryBoostManualMaxDuration | 1.3.6.1.4.1.12148.10.10.15.4 | Integer32 (0..1440) | RW | 120 | |||||||||||||||||
scalar · Integer32 (0..1440) · read-write · current A protection against overcharging. When running manual boost, the boosting will always terminate at this point. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryTest | 1.3.6.1.4.1.12148.10.10.16 | ||||||||||||||||||||
| SbatteryTestVoltage | 1.3.6.1.4.1.12148.10.10.16.1 | Integer32 | RW | 190 | |||||||||||||||||
scalar · Integer32 · read-write · current This is the battery test end voltage. The battery test will be terminated when the voltage drops below the end voltage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTestCommand | 1.3.6.1.4.1.12148.10.10.16.2 | INTEGER | RW | pushbutton(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This pushbutton will start or stop a manual battery test if the system allows it.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryTestNumberOfResults | 1.3.6.1.4.1.12148.10.10.16.3 | Integer32 (0..10) | RO | 0 | |||||||||||||||||
scalar · Integer32 (0..10) · read-only · current This is the number of valid battery test results stored in controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryTestResultTable | 1.3.6.1.4.1.12148.10.10.16.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the battery test results stored in controller. | |||||||||||||||||||||
| RbatteryTestResultEntry | 1.3.6.1.4.1.12148.10.10.16.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryTestResultIndex | 1.3.6.1.4.1.12148.10.10.16.4.1.1 | Integer32 (1..10) | NA | ||||||||||||||||||
column · Integer32 (1..10) · not-accessible · current A index pointing to one of ten possible battery test results | |||||||||||||||||||||
| CbatteryTestResultStartDateTime | 1.3.6.1.4.1.12148.10.10.16.4.1.2 | DateAndTime | RO | 07:e7:0a:1a:00:00:00:00 | |||||||||||||||||
| CbatteryTestResultDuration | 1.3.6.1.4.1.12148.10.10.16.4.1.3 | Integer32 | RO | 601 | |||||||||||||||||
| CbatteryTestResultDischarged | 1.3.6.1.4.1.12148.10.10.16.4.1.4 | Integer32 | RO | -88 | |||||||||||||||||
| CbatteryTestResultQuality | 1.3.6.1.4.1.12148.10.10.16.4.1.5 | Integer32 | RO | 100 | |||||||||||||||||
| NbatteryTempComp | 1.3.6.1.4.1.12148.10.10.17 | ||||||||||||||||||||
| SbatteryTempCompEnable | 1.3.6.1.4.1.12148.10.10.17.1 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current Enable (1) or Disable (0) of Battery Temperature Compensated output regulation mode
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryBank | 1.3.6.1.4.1.12148.10.10.18 | ||||||||||||||||||||
| SbatteryBankNumberOfBanks | 1.3.6.1.4.1.12148.10.10.18.1 | Integer32 (0..8) | RW | 1 | |||||||||||||||||
scalar · Integer32 (0..8) · read-write · current Number of battery banks installed in system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryBankTable | 1.3.6.1.4.1.12148.10.10.18.2 | NA | |||||||||||||||||||
| RbatteryBankEntry | 1.3.6.1.4.1.12148.10.10.18.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CbatteryBankIndex | 1.3.6.1.4.1.12148.10.10.18.2.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current Index used for navigating the rows 1..8 of batteryBankTable | |||||||||||||||||||||
| CbatteryBankStatus | 1.3.6.1.4.1.12148.10.10.18.2.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The overall status of battery bank
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankNumberOfTemperatures | 1.3.6.1.4.1.12148.10.10.18.2.1.3 | Integer32 (0..4) | RO | 4 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of temperature measurements in battery bank. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankNumberOfCurrents | 1.3.6.1.4.1.12148.10.10.18.2.1.4 | Integer32 (0..4) | RO | 1 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of current measurements in battery bank. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankNumberOfFuses | 1.3.6.1.4.1.12148.10.10.18.2.1.5 | Integer32 (0..4) | RO | 1 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of fuses installed in battery bank. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankNumberOfSymmetries | 1.3.6.1.4.1.12148.10.10.18.2.1.6 | Integer32 (0..4) | RO | 2 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of symmetry measurements available in battery bank. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryBankTemperatureTable | 1.3.6.1.4.1.12148.10.10.18.3 | NA | |||||||||||||||||||
| RbatteryBankTemperatureEntry | 1.3.6.1.4.1.12148.10.10.18.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryTemperatureIndex | 1.3.6.1.4.1.12148.10.10.18.3.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the temperature input table. The size of the table is defined by the batteryBankNumberOfTemp | |||||||||||||||||||||
| CbatteryTemperatureStatus | 1.3.6.1.4.1.12148.10.10.18.3.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery temperature monitor
| |||||||||||||||||||||
| CbatteryTemperatureDescription | 1.3.6.1.4.1.12148.10.10.18.3.1.3 | DisplayString (SIZE (0..16)) | RW | BatteryTemp1.1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery temperature monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CbatteryTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.18.3.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CbatteryTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.10.18.3.1.5 | INTEGER | RW | enabled(1) | |||||||||||||||||
| CbatteryTemperatureValue | 1.3.6.1.4.1.12148.10.10.18.3.1.6 | Integer32 | RO | 18 | |||||||||||||||||
column · Integer32 · read-only · current The measured battery temperature. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.10.18.3.1.7 | Integer32 | RW | 40 | |||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.10.18.3.1.8 | Integer32 | RW | 30 | |||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.10.18.3.1.9 | Integer32 | RW | -5 | |||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.10.18.3.1.10 | Integer32 | RW | -10 | |||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryBankCurrentTable | 1.3.6.1.4.1.12148.10.10.18.4 | NA | |||||||||||||||||||
| RbatteryBankCurrentEntry | 1.3.6.1.4.1.12148.10.10.18.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryCurrentIndex | 1.3.6.1.4.1.12148.10.10.18.4.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the current input table. The size of the table is defined by the system | |||||||||||||||||||||
| CbatteryCurrentStatus | 1.3.6.1.4.1.12148.10.10.18.4.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery current monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryCurrentDescription | 1.3.6.1.4.1.12148.10.10.18.4.1.3 | DisplayString (SIZE (0..16)) | RW | BattCurrent1.1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery current monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.18.4.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CbatteryCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.10.18.4.1.5 | INTEGER | RW | enabled(1) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryCurrentValue | 1.3.6.1.4.1.12148.10.10.18.4.1.6 | Integer32 | RO | 2 | |||||||||||||||||
column · Integer32 · read-only · current The measured battery current Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryCurrentMajorHighLevel | 1.3.6.1.4.1.12148.10.10.18.4.1.7 | Integer32 | RW | 1000 | |||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryCurrentMinorHighLevel | 1.3.6.1.4.1.12148.10.10.18.4.1.8 | Integer32 | RW | 900 | |||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryCurrentMinorLowLevel | 1.3.6.1.4.1.12148.10.10.18.4.1.9 | Integer32 | RW | -900 | |||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryCurrentMajorLowLevel | 1.3.6.1.4.1.12148.10.10.18.4.1.10 | Integer32 | RW | -1000 | |||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryBankFuseTable | 1.3.6.1.4.1.12148.10.10.18.5 | NA | |||||||||||||||||||
| RbatteryBankFuseEntry | 1.3.6.1.4.1.12148.10.10.18.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryFuseIndex | 1.3.6.1.4.1.12148.10.10.18.5.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the fuse table. The size of the table is defined by the system | |||||||||||||||||||||
| CbatteryFuseStatus | 1.3.6.1.4.1.12148.10.10.18.5.1.2 | INTEGER | RO | disabled(4) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery fuse monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryFuseDescription | 1.3.6.1.4.1.12148.10.10.18.5.1.3 | DisplayString (SIZE (0..16)) | RW | BattFuses 1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery fuse monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryFuseTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.18.5.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CbatteryFuseAlarmEnable | 1.3.6.1.4.1.12148.10.10.18.5.1.5 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryFuseValue | 1.3.6.1.4.1.12148.10.10.18.5.1.6 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current The measured value of battery fuse input. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryBankSymmetryTable | 1.3.6.1.4.1.12148.10.10.18.6 | NA | |||||||||||||||||||
| RbatteryBankSymmetryEntry | 1.3.6.1.4.1.12148.10.10.18.6.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryBankSymmetryIndex | 1.3.6.1.4.1.12148.10.10.18.6.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current This index denotes which row in the symmetry input table. The size of the table is defined by the batteryMonitorNumberOfSymmetries | |||||||||||||||||||||
| CbatteryBankSymmetryStatus | 1.3.6.1.4.1.12148.10.10.18.6.1.2 | INTEGER | RO | disabled(4) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery symmetry monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankSymmetryDescription | 1.3.6.1.4.1.12148.10.10.18.6.1.3 | DisplayString (SIZE (0..16)) | RW | SymmVolt 1.1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery monitor symmetry. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankSymmetryTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.18.6.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CbatteryBankSymmetryAlarmEnable | 1.3.6.1.4.1.12148.10.10.18.6.1.5 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankSymmetryMeasureValue | 1.3.6.1.4.1.12148.10.10.18.6.1.6 | Integer32 | RO | 242 | |||||||||||||||||
column · Integer32 · read-only · current The measured battery symmetry voltage in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankSymmetryDeltaValue | 1.3.6.1.4.1.12148.10.10.18.6.1.7 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current The measured battery symmetry delta voltage in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankSymmetryMajorAlarmLevel | 1.3.6.1.4.1.12148.10.10.18.6.1.8 | Integer32 | RW | 150 | |||||||||||||||||
column · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryBankSymmetryMinorAlarmLevel | 1.3.6.1.4.1.12148.10.10.18.6.1.9 | Integer32 | RW | 100 | |||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryMonitors | 1.3.6.1.4.1.12148.10.10.19 | ||||||||||||||||||||
| SbatteryMonitorsNumberOfUnits | 1.3.6.1.4.1.12148.10.10.19.1 | Integer32 | RW | 0 | |||||||||||||||||
scalar · Integer32 · read-write · current The number of battery monitor installed in system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryMonitorsTable | 1.3.6.1.4.1.12148.10.10.19.2 | NA | |||||||||||||||||||
| RbatteryMonitorsEntry | 1.3.6.1.4.1.12148.10.10.19.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CbatteryMonitorIndex | 1.3.6.1.4.1.12148.10.10.19.2.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current Index used for navigating the rows 1..8 of batteryMonitorsTable | |||||||||||||||||||||
| CbatteryMonitorNumberOfTemperatures | 1.3.6.1.4.1.12148.10.10.19.2.1.2 | Integer32 (0..4) | RO | 1 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current The number of temperature measurements in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorNumberOfCurrents | 1.3.6.1.4.1.12148.10.10.19.2.1.3 | Integer32 (0..4) | RO | 1 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current The number of current measurements in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorNumberOfFuses | 1.3.6.1.4.1.12148.10.10.19.2.1.4 | Integer32 (0..4) | RO | 1 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current The number of fuse measurements in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorNumberOfSymmetries | 1.3.6.1.4.1.12148.10.10.19.2.1.5 | Integer32 (0..4) | RO | 4 | |||||||||||||||||
column · Integer32 (0..4) · read-only · current The number of symmetry measurements in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryMonitorTemperatureTable | 1.3.6.1.4.1.12148.10.10.19.3 | NA | |||||||||||||||||||
| RbatteryMonitorTemperatureEntry | 1.3.6.1.4.1.12148.10.10.19.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryMonitorTemperatureIndex | 1.3.6.1.4.1.12148.10.10.19.3.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the temperature input table. The size of the table is defined by the batteryMonitorNumberOfTemperatures | |||||||||||||||||||||
| CbatteryMonitorTemperatureStatus | 1.3.6.1.4.1.12148.10.10.19.3.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery temperature monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorTemperatureDescription | 1.3.6.1.4.1.12148.10.10.19.3.1.3 | DisplayString (SIZE (0..16)) | RW | BattMonTemp 1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery monitor temperature. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.19.3.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CbatteryMonitorTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.10.19.3.1.5 | INTEGER | RW | enabled(1) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorTemperatureValue | 1.3.6.1.4.1.12148.10.10.19.3.1.6 | Integer32 | RO | 17 | |||||||||||||||||
column · Integer32 · read-only · current The measured battery temperature in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.10.19.3.1.7 | Integer32 | RW | 40 | |||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.10.19.3.1.8 | Integer32 | RW | 32 | |||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.10.19.3.1.9 | Integer32 | RW | -5 | |||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.10.19.3.1.10 | Integer32 | RW | -10 | |||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryMonitorCurrentTable | 1.3.6.1.4.1.12148.10.10.19.4 | NA | |||||||||||||||||||
| RbatteryMonitorCurrentEntry | 1.3.6.1.4.1.12148.10.10.19.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryMonitorCurrentIndex | 1.3.6.1.4.1.12148.10.10.19.4.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the current input table. The size of the table is defined by the batteryMonitorNumberOfCurrents | |||||||||||||||||||||
| CbatteryMonitorCurrentStatus | 1.3.6.1.4.1.12148.10.10.19.4.1.2 | INTEGER | RO | disabled(4) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery current monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorCurrentDescription | 1.3.6.1.4.1.12148.10.10.19.4.1.3 | DisplayString (SIZE (0..16)) | RW | BattMonCurr 1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery monitor current. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.19.4.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CbatteryMonitorCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.10.19.4.1.5 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorCurrentValue | 1.3.6.1.4.1.12148.10.10.19.4.1.6 | Integer32 | RO | 3 | |||||||||||||||||
column · Integer32 · read-only · current The measured battery current in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorCurrentMajorHighLevel | 1.3.6.1.4.1.12148.10.10.19.4.1.7 | Integer32 | RW | 1000 | |||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorCurrentMinorHighLevel | 1.3.6.1.4.1.12148.10.10.19.4.1.8 | Integer32 | RW | 900 | |||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorCurrentMinorLowLevel | 1.3.6.1.4.1.12148.10.10.19.4.1.9 | Integer32 | RW | -900 | |||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorCurrentMajorLowLevel | 1.3.6.1.4.1.12148.10.10.19.4.1.10 | Integer32 | RW | -1000 | |||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryMonitorFuseTable | 1.3.6.1.4.1.12148.10.10.19.5 | NA | |||||||||||||||||||
| RbatteryMonitorFuseEntry | 1.3.6.1.4.1.12148.10.10.19.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryMonitorFuseIndex | 1.3.6.1.4.1.12148.10.10.19.5.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the fuse table. The size of the table is defined by the batteryMonitorNumberOfFuses | |||||||||||||||||||||
| CbatteryMonitorFuseStatus | 1.3.6.1.4.1.12148.10.10.19.5.1.2 | INTEGER | RO | disabled(4) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery fuse monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorFuseDescription | 1.3.6.1.4.1.12148.10.10.19.5.1.3 | DisplayString (SIZE (0..16)) | RW | BattMonFuse 1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery monitor fuse. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorFuseTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.19.5.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CbatteryMonitorFuseAlarmEnable | 1.3.6.1.4.1.12148.10.10.19.5.1.5 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorFuseValue | 1.3.6.1.4.1.12148.10.10.19.5.1.6 | Integer32 | RO | 1 | |||||||||||||||||
column · Integer32 · read-only · current The measured value of battery fuse in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryMonitorSymmetryTable | 1.3.6.1.4.1.12148.10.10.19.6 | NA | |||||||||||||||||||
| RbatteryMonitorSymmetryEntry | 1.3.6.1.4.1.12148.10.10.19.6.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryMonitorSymmetryIndex | 1.3.6.1.4.1.12148.10.10.19.6.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current This index denotes which row in the symmetry input table. The size of the table is defined by the batteryMonitorNumberOfSymmetries | |||||||||||||||||||||
| CbatteryMonitorSymmetryStatus | 1.3.6.1.4.1.12148.10.10.19.6.1.2 | INTEGER | RO | disabled(4) | |||||||||||||||||
column · INTEGER · read-only · current The status of battery symmetry monitor
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorSymmetryDescription | 1.3.6.1.4.1.12148.10.10.19.6.1.3 | DisplayString (SIZE (0..16)) | RW | BattMonSym1.1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery monitor symmetry. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CbatteryMonitorSymmetryTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.19.6.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CbatteryMonitorSymmetryAlarmEnable | 1.3.6.1.4.1.12148.10.10.19.6.1.5 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorSymmetryMeasureValue | 1.3.6.1.4.1.12148.10.10.19.6.1.6 | Integer32 | RO | 2768 | |||||||||||||||||
| CbatteryMonitorSymmetryDeltaValue | 1.3.6.1.4.1.12148.10.10.19.6.1.7 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current The measured battery symmetry delta voltage in battery monitor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorSymmetryMajorAlarmLevel | 1.3.6.1.4.1.12148.10.10.19.6.1.8 | Integer32 | RW | 150 | |||||||||||||||||
column · Integer32 · read-write · current The major alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CbatteryMonitorSymmetryMinorAlarmLevel | 1.3.6.1.4.1.12148.10.10.19.6.1.9 | Integer32 | RW | 100 | |||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryEnergyLog | 1.3.6.1.4.1.12148.10.10.20 | ||||||||||||||||||||
| SbatteryEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.10.20.1 | Integer32 | RO | -52726 | |||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered to/from battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.10.20.2 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in battery hourly energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.10.20.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of battery. | |||||||||||||||||||||
| RbatteryEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.10.20.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.10.20.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryEnergyLogLastHoursTable | |||||||||||||||||||||
| CbatteryEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.10.20.3.1.2 | Integer32 | RO | -10 | |||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.10.20.4 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in battery daily energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.10.20.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of battery. | |||||||||||||||||||||
| RbatteryEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.10.20.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.10.20.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryEnergyLogLastDaysTable | |||||||||||||||||||||
| CbatteryEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.10.20.5.1.2 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.10.20.6 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in battery weekly energy log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.10.20.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of battery. | |||||||||||||||||||||
| RbatteryEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.10.20.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.10.20.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryEnergyLogLastWeekTable | |||||||||||||||||||||
| CbatteryEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.10.20.7.1.2 | Integer32 | RO | -2 | |||||||||||||||||
| NbatteryCycleLog | 1.3.6.1.4.1.12148.10.10.21 | ||||||||||||||||||||
| SbatteryCycleLogTotalCycles | 1.3.6.1.4.1.12148.10.10.21.1 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current This is the total number of battery discharge cycles. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCycleLogDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.10.21.2 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in daily battery discharge cycle log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryCycleLogDaysTable | 1.3.6.1.4.1.12148.10.10.21.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily battery discharge cycle log. | |||||||||||||||||||||
| RbatteryCycleLogDaysEntry | 1.3.6.1.4.1.12148.10.10.21.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryCycleLogDaysIndex | 1.3.6.1.4.1.12148.10.10.21.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryCycleLogLastDaysTable | |||||||||||||||||||||
| CbatteryCycleLogDaysValue | 1.3.6.1.4.1.12148.10.10.21.3.1.2 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Number of discharge cycles logged every day. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCycleLogWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.10.21.4 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in weeky battery discharge cycle log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryCycleLogWeeksTable | 1.3.6.1.4.1.12148.10.10.21.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly battery discharge cycle log. | |||||||||||||||||||||
| RbatteryCycleLogWeeksEntry | 1.3.6.1.4.1.12148.10.10.21.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryCycleLogWeeksIndex | 1.3.6.1.4.1.12148.10.10.21.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryCycleLogLastWeeksTable | |||||||||||||||||||||
| CbatteryCycleLogWeeksValue | 1.3.6.1.4.1.12148.10.10.21.5.1.2 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Number of discharge cycles logged every week. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryCycleLogMonthsNumberOfEntries | 1.3.6.1.4.1.12148.10.10.21.6 | Integer32 (0..52) | RO | 52 | |||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in monthly battery discharge cycle log. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TbatteryCycleLogMonthsTable | 1.3.6.1.4.1.12148.10.10.21.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains monthly battery discharge cycle log. | |||||||||||||||||||||
| RbatteryCycleLogMonthsEntry | 1.3.6.1.4.1.12148.10.10.21.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryCycleLogMonthsIndex | 1.3.6.1.4.1.12148.10.10.21.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryCycleLogLastMonthTable | |||||||||||||||||||||
| CbatteryCycleLogMonthsValue | 1.3.6.1.4.1.12148.10.10.21.7.1.2 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Number of discharge cycles logged every month. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryEqualize | 1.3.6.1.4.1.12148.10.10.22 | ||||||||||||||||||||
| SbatteryEqualizeVoltage | 1.3.6.1.4.1.12148.10.10.22.1 | Integer32 (870..60418) | RW | 5450 | |||||||||||||||||
scalar · Integer32 (870..60418) · read-write · current The Voltage at which the DC System equalize charges the batteries. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryEqualizeCommand | 1.3.6.1.4.1.12148.10.10.22.2 | INTEGER | RW | pushbutton(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This pushbutton will start or stop a manual battery equalize if the system allows it.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryEqualizeCurrentThreshold | 1.3.6.1.4.1.12148.10.10.22.3 | Integer32 | RW | 10 | |||||||||||||||||
scalar · Integer32 · read-write · current The equalizing will terminate when the charge current drops below the EqualizeCurrentThreshold limit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryEqualizeManualMaxDuration | 1.3.6.1.4.1.12148.10.10.22.4 | Integer32 (0..1440) | RW | 120 | |||||||||||||||||
scalar · Integer32 (0..1440) · read-write · current A protection against overcharging. When running manual equalize, the boosting will always terminate at this point. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryAhCharged | 1.3.6.1.4.1.12148.10.10.23 | ||||||||||||||||||||
| SbatteryAhChargedStatus | 1.3.6.1.4.1.12148.10.10.23.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery ah charged monitor.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhChargedDescription | 1.3.6.1.4.1.12148.10.10.23.2 | DisplayString (SIZE (0..16)) | RW | Ah Charged | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery ah charged monitor. This is stored in the system controller and can be changed by the user Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhChargedTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.23.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryAhChargedAlarmEnable | 1.3.6.1.4.1.12148.10.10.23.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhChargedValue | 1.3.6.1.4.1.12148.10.10.23.5 | Integer32 | RO | 0 | |||||||||||||||||
scalar · Integer32 · read-only · current The calculated battery ah (x100) charged value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhChargedMinorHighLevel | 1.3.6.1.4.1.12148.10.10.23.6 | Integer32 | RW | 900 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhChargedMajorHighLevel | 1.3.6.1.4.1.12148.10.10.23.7 | Integer32 | RW | 1000 | |||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NbatteryAhDischarged | 1.3.6.1.4.1.12148.10.10.24 | ||||||||||||||||||||
| SbatteryAhDischargedStatus | 1.3.6.1.4.1.12148.10.10.24.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery ah discharged monitor.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhDischargedDescription | 1.3.6.1.4.1.12148.10.10.24.2 | DisplayString (SIZE (0..16)) | RW | Ah Discharged | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery ah discharged monitor. This is stored in the system controller and can be changed by the user Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhDischargedTrapRepeatCounter | 1.3.6.1.4.1.12148.10.10.24.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryAhDischargedAlarmEnable | 1.3.6.1.4.1.12148.10.10.24.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhDischargedValue | 1.3.6.1.4.1.12148.10.10.24.5 | Integer32 | RO | 7 | |||||||||||||||||
scalar · Integer32 · read-only · current The calculated battery ah (x100) discharged value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhDischargedMinorHighLevel | 1.3.6.1.4.1.12148.10.10.24.6 | Integer32 | RW | 900 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SbatteryAhDischargedMajorHighLevel | 1.3.6.1.4.1.12148.10.10.24.7 | Integer32 | RW | 1000 | |||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| Ninputs | 1.3.6.1.4.1.12148.10.11 | ||||||||||||||||||||
| TinputControlUnitsTable | 1.3.6.1.4.1.12148.10.11.1 | NA | |||||||||||||||||||
| RinputControlUnitsEntry | 1.3.6.1.4.1.12148.10.11.1.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinputControlUnitIndex | 1.3.6.1.4.1.12148.10.11.1.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of inputControlUnitTable The size of the table is defined by the system | |||||||||||||||||||||
| CinputControlUnitNumberOfInputs | 1.3.6.1.4.1.12148.10.11.1.1.2 | Integer32 (0..8) | RO | ||||||||||||||||||
column · Integer32 (0..8) · read-only · current Number of programmable inputs available in controller. | |||||||||||||||||||||
| TinputControlUnitInputTable | 1.3.6.1.4.1.12148.10.11.2 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the status of the programmable inputs for Control Units. | |||||||||||||||||||||
| RinputControlUnitInputEntry | 1.3.6.1.4.1.12148.10.11.2.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinputControlUnitInputIndex | 1.3.6.1.4.1.12148.10.11.2.1.1 | Integer32 (1..10) | NA | ||||||||||||||||||
column · Integer32 (1..10) · not-accessible · current Index used for navigating the rows of inputControlUnitInputTable The size of the table is defined by the inputControlUnitNumberOfInputs | |||||||||||||||||||||
| CinputControlUnitInputStatus | 1.3.6.1.4.1.12148.10.11.2.1.2 | INTEGER | RO | disabled(4) | |||||||||||||||||
column · INTEGER · read-only · current Programmable input status.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CinputControlUnitInputDescription | 1.3.6.1.4.1.12148.10.11.2.1.3 | DisplayString (SIZE (0..16)) | RW | Virtual input 1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the programmable input. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CinputControlUnitInputTrapRepeatCounter | 1.3.6.1.4.1.12148.10.11.2.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CinputControlUnitInputAlarmEnable | 1.3.6.1.4.1.12148.10.11.2.1.5 | INTEGER | RW | disabled(0) | |||||||||||||||||
column · INTEGER · read-write · current This will enable or disable this inputs Alarm functionality. Setting 'disabled' here will turn off lock the status to 'disabled' state
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CinputControlUnitInputValue | 1.3.6.1.4.1.12148.10.11.2.1.6 | Integer32 | RW | 0 | |||||||||||||||||
column · Integer32 · read-write · current The inputs measured Value. Depending on the type of input, this may represent a Voltage, a Temperature, a Current or a Boolean value. Note: This value can only be set for virtual input on SP2 master or Smartpack S. When this value is set to '0', the input is deactivated; When this value is set to '1', the input is activated; if set to any other value, an Inconsistent Value error will be generated. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CinputControlUnitInputConfiguration | 1.3.6.1.4.1.12148.10.11.2.1.7 | INTEGER | RW | virtual(6) | |||||||||||||||||
column · INTEGER · read-write · current Configuration of the input type. Configurations available for different controllers are as follows: SP2 Master(clock, virtual), SP2 Basic(normally open, normally closed),Compack(normally open, normally closed, diode matrix, voltage, clock), SmartpackS(normally open, normally closed,voltage)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TinputIoUnitsTable | 1.3.6.1.4.1.12148.10.11.3 | NA | |||||||||||||||||||
| RinputIoUnitsEntry | 1.3.6.1.4.1.12148.10.11.3.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinputIoUnitIndex | 1.3.6.1.4.1.12148.10.11.3.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of inputIoUnitsTable The size of the table is defined by the system | |||||||||||||||||||||
| CinputIoUnitNumberOfInputs | 1.3.6.1.4.1.12148.10.11.3.1.2 | Integer32 (0..8) | RO | ||||||||||||||||||
column · Integer32 (0..8) · read-only · current Number of programmable inputs available in IO unit. | |||||||||||||||||||||
| TinputIoUnitProgInputTable | 1.3.6.1.4.1.12148.10.11.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the status of the programmable inputs for I/O monitor units. . | |||||||||||||||||||||
| RinputIoUnitProgInputEntry | 1.3.6.1.4.1.12148.10.11.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinputIoUnitProgInputIndex | 1.3.6.1.4.1.12148.10.11.4.1.1 | Integer32 (1..6) | NA | ||||||||||||||||||
column · Integer32 (1..6) · not-accessible · current The Index to the Input of the selected I/O monitor unit. Or the input number if you like. | |||||||||||||||||||||
| CinputIoUnitProgInputStatus | 1.3.6.1.4.1.12148.10.11.4.1.2 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current Programmable input status.
| |||||||||||||||||||||
| CinputIoUnitProgInputDescription | 1.3.6.1.4.1.12148.10.11.4.1.3 | DisplayString (SIZE (0..16)) | RW | Adgang Alarm | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the programmable input in IO unit. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CinputIoUnitProgInputTrapRepeatCounter | 1.3.6.1.4.1.12148.10.11.4.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CinputIoUnitProgInputAlarmEnable | 1.3.6.1.4.1.12148.10.11.4.1.5 | INTEGER | RW | enabled(1) | |||||||||||||||||
column · INTEGER · read-write · current This will enable or disable this inputs Alarm functionality. Setting 'disabled' here will turn off lock the status to 'disabled' state
| |||||||||||||||||||||
| CinputIoUnitProgInputValue | 1.3.6.1.4.1.12148.10.11.4.1.6 | Integer32 | RO | 0 | |||||||||||||||||
| CinputIoUnitProgInputConfiguration | 1.3.6.1.4.1.12148.10.11.4.1.7 | INTEGER | RW | normallyClosed(2) | |||||||||||||||||
column · INTEGER · read-write · current Configuration of the input type. Configurations available for IO unit are normally open, normally closed, diode matrix, voltage and clock. Note: If an input is set to 'clock', it can not be configurated to 'normally open', 'normally closed' and 'diode matrix' directly, it has to be configurated to 'voltage' first.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Noutputs | 1.3.6.1.4.1.12148.10.12 | ||||||||||||||||||||
| ToutputControlUnitTable | 1.3.6.1.4.1.12148.10.12.1 | NA | |||||||||||||||||||
| RoutputControlUnitEntry | 1.3.6.1.4.1.12148.10.12.1.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CoutputControlUnitIndex | 1.3.6.1.4.1.12148.10.12.1.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of outputControlUnitTable The size of the table is defined by the system | |||||||||||||||||||||
| CoutputControlUnitNumberOfOutputs | 1.3.6.1.4.1.12148.10.12.1.1.2 | Integer32 (0..8) | RO | ||||||||||||||||||
column · Integer32 (0..8) · read-only · current Number of outputs available in controller. | |||||||||||||||||||||
| ToutputControlUnitOutputTable | 1.3.6.1.4.1.12148.10.12.2 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the status of the outputs for Control Units. | |||||||||||||||||||||
| RoutputControlUnitOutputEntry | 1.3.6.1.4.1.12148.10.12.2.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CoutputControlUnitOutputIndex | 1.3.6.1.4.1.12148.10.12.2.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Index used for navigating the rows of outputControlUnitoutputTable The size of the table is defined by the outputControlUnitNumberOfOutputs | |||||||||||||||||||||
| CoutputControlUnitOutputStatus | 1.3.6.1.4.1.12148.10.12.2.1.2 | INTEGER | RO | energized(1) | |||||||||||||||||
column · INTEGER · read-only · current General output relays may be 'energized' or 'not energized'. 'energized' and 'not energized' correspond to normal and alarm condition respectively for normally activated configuration. Latched contactors may have values 'disconnected' or 'connected'
| |||||||||||||||||||||
| CoutputControlUnitOutputDescription | 1.3.6.1.4.1.12148.10.12.2.1.3 | DisplayString (SIZE (0..16)) | RW | Alarm out. 1.1 | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the output. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| ToutputIoUnitTable | 1.3.6.1.4.1.12148.10.12.3 | NA | |||||||||||||||||||
| RoutputIoUnitEntry | 1.3.6.1.4.1.12148.10.12.3.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CoutputIoUnitIndex | 1.3.6.1.4.1.12148.10.12.3.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of outputIoUnitTable The size of the table is defined by the system | |||||||||||||||||||||
| CoutputIoUnitNumberOfOutputs | 1.3.6.1.4.1.12148.10.12.3.1.2 | Integer32 (0..8) | RO | ||||||||||||||||||
column · Integer32 (0..8) · read-only · current Number of outputs available in IO unit. | |||||||||||||||||||||
| ToutputIoUnitOutputTable | 1.3.6.1.4.1.12148.10.12.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the status of the outputs for IO Units. | |||||||||||||||||||||
| RoutputIoUnitOutputEntry | 1.3.6.1.4.1.12148.10.12.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CoutputIoUnitOutputIndex | 1.3.6.1.4.1.12148.10.12.4.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of outputIOUnitOutputTable The size of the table is defined by the outputIOUnitNumberOfOutputs | |||||||||||||||||||||
| CoutputIoUnitOutputStatus | 1.3.6.1.4.1.12148.10.12.4.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current General output relays may be 'energized' or 'not energized'. Latched contactors may have values 'disconnected' or 'connected'
| |||||||||||||||||||||
| CoutputIoUnitOutputDescription | 1.3.6.1.4.1.12148.10.12.4.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the output in IO unit. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| NcontrolSystem | 1.3.6.1.4.1.12148.10.13 | ||||||||||||||||||||
| ScontrolSystemStatus | 1.3.6.1.4.1.12148.10.13.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The overall status of control system subsystem
| |||||||||||||||||||||
| ScontrolSystemClock | 1.3.6.1.4.1.12148.10.13.2 | DateAndTime (SIZE (8..11)) | RW | ||||||||||||||||||
scalar · DateAndTime (SIZE (8..11)) · read-write · current This is the system time. | |||||||||||||||||||||
| ScontrolSystemNumberOfControlUnits | 1.3.6.1.4.1.12148.10.13.3 | Integer32 (1..14) | RW | ||||||||||||||||||
scalar · Integer32 (1..14) · read-write · current Total number of main controllers (SP2 Master, SP2 Basic Ind, SP2 Basic, Compack, Smartpack S, Smartpack) | |||||||||||||||||||||
| Nsnmp | 1.3.6.1.4.1.12148.10.13.4 | ||||||||||||||||||||
| SsnmpSendOffTraps | 1.3.6.1.4.1.12148.10.13.4.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When this is enabled, a trap is sent when a alarm condition goes off .
| |||||||||||||||||||||
| SsnmpTrapRepeatRate | 1.3.6.1.4.1.12148.10.13.4.2 | Integer32 (0..1440) | RW | ||||||||||||||||||
scalar · Integer32 (0..1440) · read-write · current The time between every repeated trap when an alarm condition is on. To turn repetetive traps off, set to zero. Can be 0 to 1440 minutes i.e 24 hours. | |||||||||||||||||||||
| SsnmpHeartBeatTrapRepeatRate | 1.3.6.1.4.1.12148.10.13.4.3 | Integer32 (0..1440) | RW | ||||||||||||||||||
scalar · Integer32 (0..1440) · read-write · current The time between every heartbeat trap when an alarm condition is on. To turn heartbeat traps off, set to zero. Can be 0 to 1440 minutes i.e 24 hours. | |||||||||||||||||||||
| SsnmpInhibitTraps | 1.3.6.1.4.1.12148.10.13.4.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When this is enabled, no trap is sent regardless of alarm conditions.
| |||||||||||||||||||||
| ScontrolSystemResetManualAlarms | 1.3.6.1.4.1.12148.10.13.5 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Reset manual alarms and put buzzer into silence.
| |||||||||||||||||||||
| ScontrolSystemResetNumberOfModules | 1.3.6.1.4.1.12148.10.13.6 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current If set to '1', the number of modules (rectifier, solar charger, wind charger, control units, etc.) will be reset, and only those modules communicating are counted.
| |||||||||||||||||||||
| NcontrolSystemIoUnits | 1.3.6.1.4.1.12148.10.13.7 | ||||||||||||||||||||
| ScontrolSystemIoUnitsNumberOfUnits | 1.3.6.1.4.1.12148.10.13.7.1 | Integer32 (0..14) | RW | ||||||||||||||||||
scalar · Integer32 (0..14) · read-write · current This is the number of IO units installed in the system. | |||||||||||||||||||||
| TcontrolSystemIoUnitsTable | 1.3.6.1.4.1.12148.10.13.7.2 | NA | |||||||||||||||||||
| RcontrolSystemIoUnitsEntry | 1.3.6.1.4.1.12148.10.13.7.2.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcontrolSystemIoUnitIndex | 1.3.6.1.4.1.12148.10.13.7.2.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of controlSystemIoUnitTable The size of the table is defined by the system | |||||||||||||||||||||
| CcontrolSystemIoUnitNumberOfTemperatures | 1.3.6.1.4.1.12148.10.13.7.2.1.2 | Integer32 (0..4) | RO | ||||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of temperature measurements available in IO unit | |||||||||||||||||||||
| CcontrolSystemIoUnitNumberOfFans | 1.3.6.1.4.1.12148.10.13.7.2.1.3 | Integer32 (0..4) | RO | ||||||||||||||||||
column · Integer32 (0..4) · read-only · current Number of fan measurements available in IO unit | |||||||||||||||||||||
| TcontrolSystemIoUnitTemperatureTable | 1.3.6.1.4.1.12148.10.13.7.3 | NA | |||||||||||||||||||
| RcontrolSystemIoUnitTemperatureEntry | 1.3.6.1.4.1.12148.10.13.7.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureIndex | 1.3.6.1.4.1.12148.10.13.7.3.1.1 | Integer32 (1..2) | NA | ||||||||||||||||||
column · Integer32 (1..2) · not-accessible · current Index used for navigating the rows of controlSystemIoUnitTemperatureTable The size of the table is defined by the controlSystemIoUnitNumberOfTemperatures | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureStatus | 1.3.6.1.4.1.12148.10.13.7.3.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of temperature monitor
| |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureDescription | 1.3.6.1.4.1.12148.10.13.7.3.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the temperature monitor in control system. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.7.3.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.13.7.3.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureValue | 1.3.6.1.4.1.12148.10.13.7.3.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured temperature value. | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.13.7.3.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.13.7.3.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.13.7.3.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CcontrolSystemIoUnitTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.13.7.3.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| TcontrolSystemIoUnitFanTable | 1.3.6.1.4.1.12148.10.13.7.4 | NA | |||||||||||||||||||
| RcontrolSystemIoUnitFanEntry | 1.3.6.1.4.1.12148.10.13.7.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcontrolSystemIoUnitFanIndex | 1.3.6.1.4.1.12148.10.13.7.4.1.1 | Integer32 (1..2) | NA | ||||||||||||||||||
column · Integer32 (1..2) · not-accessible · current Index used for navigating the rows 1..2 of ioUnitFan Table | |||||||||||||||||||||
| CcontrolSystemIoUnitFanSpeedValue | 1.3.6.1.4.1.12148.10.13.7.4.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured fan speed | |||||||||||||||||||||
| CcontrolSystemIoUnitFanSpeedDeviation | 1.3.6.1.4.1.12148.10.13.7.4.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured fan speed deviation | |||||||||||||||||||||
| CcontrolSystemIoUnitFanControl | 1.3.6.1.4.1.12148.10.13.7.4.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Fan speed control value in percentage | |||||||||||||||||||||
| NcontrolSystemInventory | 1.3.6.1.4.1.12148.10.13.8 | ||||||||||||||||||||
| ScontrolUnitNumberOfUnits | 1.3.6.1.4.1.12148.10.13.8.1 | Integer32 (1..254) | RO | ||||||||||||||||||
scalar · Integer32 (1..254) · read-only · current Total number of control units installed in system. | |||||||||||||||||||||
| TcontrolUnitTable | 1.3.6.1.4.1.12148.10.13.8.2 | NA | |||||||||||||||||||
table · not-accessible · current A table containing an inventory listing. Each row represent one of the system hardware unit that is connected to the can bus. These units are system controllers, battery monitors, I/O units, AC Mains Monitor boxes and load monitors. Due to the system architechture the tables index are not contiguous. Each unit type har its own address range on the can bus. All unit types except the system controller may contain from 0 to 14 units. The system controlller can never be zero. Then there is no powersystem. | |||||||||||||||||||||
| RcontrolUnitEntry | 1.3.6.1.4.1.12148.10.13.8.2.1 | NA | |||||||||||||||||||
row · not-accessible · current One row in the table containing all hardware units connected to the canbus.
| |||||||||||||||||||||
| CcontrolUnitIndex | 1.3.6.1.4.1.12148.10.13.8.2.1.1 | Integer32 (1..254) | NA | ||||||||||||||||||
column · Integer32 (1..254) · not-accessible · current Index used for navigating the rows of controlUnitTable The size of the table is defined by the controlUnitNumberOfUnits | |||||||||||||||||||||
| CcontrolUnitDescription | 1.3.6.1.4.1.12148.10.13.8.2.1.2 | DisplayString (SIZE (0..32)) | RO | Micropack System | |||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current A textual description of the control unit Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrolUnitStatus | 1.3.6.1.4.1.12148.10.13.8.2.1.3 | INTEGER | RO | normal(1) | |||||||||||||||||
column · INTEGER · read-only · current The overall status of the control unit.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrolUnitSerialNumber | 1.3.6.1.4.1.12148.10.13.8.2.1.4 | DisplayString (SIZE (0..12)) | RO | 141571157665 | |||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Serial number of the control unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrolUnitHwPartNumber | 1.3.6.1.4.1.12148.10.13.8.2.1.5 | DisplayString (SIZE (0..12)) | RO | 242100.500 | |||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of the control unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrolUnitHwVersion | 1.3.6.1.4.1.12148.10.13.8.2.1.6 | DisplayString (SIZE (0..20)) | RO | 2.1 | |||||||||||||||||
column · DisplayString (SIZE (0..20)) · read-only · current Hardware version of the control unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrolUnitSwPartNumber | 1.3.6.1.4.1.12148.10.13.8.2.1.7 | DisplayString (SIZE (0..12)) | RO | 405006.009 | |||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Software part number of the control unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrolUnitSwVersion | 1.3.6.1.4.1.12148.10.13.8.2.1.8 | DisplayString (SIZE (0..20)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..20)) · read-only · current Software version of the control unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NcurrentMonitors | 1.3.6.1.4.1.12148.10.13.9 | ||||||||||||||||||||
| ScurrentMonitorsNumberOfUnits | 1.3.6.1.4.1.12148.10.13.9.1 | Integer32 (0..14) | RW | ||||||||||||||||||
scalar · Integer32 (0..14) · read-write · current This is the number of current monitors installed in the system. | |||||||||||||||||||||
| TcurrentMonitorsTable | 1.3.6.1.4.1.12148.10.13.9.2 | NA | |||||||||||||||||||
| RcurrentMonitorsEntry | 1.3.6.1.4.1.12148.10.13.9.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CcurrentMonitorIndex | 1.3.6.1.4.1.12148.10.13.9.2.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of currentMonitorsTable The size of the table is defined by the system | |||||||||||||||||||||
| CcurrentMonitorType | 1.3.6.1.4.1.12148.10.13.9.2.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This shows if the current monitor is configured as standard load monitor (1), load current monitor (2), rectifier current monitor (3), dcdc current monitor (4), solar current monitor (5), wind current monitor (6) or fuel cell current monitor (7).
| |||||||||||||||||||||
| CcurrentMonitorId | 1.3.6.1.4.1.12148.10.13.9.2.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the unit index for each current monitor type. | |||||||||||||||||||||
| CcurrentMonitorNumberOfFuses | 1.3.6.1.4.1.12148.10.13.9.2.1.4 | Integer32 (0..8) | RO | ||||||||||||||||||
column · Integer32 (0..8) · read-only · current Number of fuse measurements in current monitor. | |||||||||||||||||||||
| CcurrentMonitorNumberOfCurrents | 1.3.6.1.4.1.12148.10.13.9.2.1.5 | Integer32 (0..8) | RO | ||||||||||||||||||
column · Integer32 (0..8) · read-only · current Number of current measurements in current monitor. | |||||||||||||||||||||
| TcurrentMonitorFuseTable | 1.3.6.1.4.1.12148.10.13.9.3 | NA | |||||||||||||||||||
| RcurrentMonitorFuseEntry | 1.3.6.1.4.1.12148.10.13.9.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcurrentMonitorFuseIndex | 1.3.6.1.4.1.12148.10.13.9.3.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current Index used for navigating the rows of currentMonitorFuseTable The size of the table is defined by the currentMonitorNumberOfFuses | |||||||||||||||||||||
| CcurrentMonitorFuseStatus | 1.3.6.1.4.1.12148.10.13.9.3.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of fuse in current monitor
| |||||||||||||||||||||
| CcurrentMonitorFuseDescription | 1.3.6.1.4.1.12148.10.13.9.3.1.3 | DisplayString (SIZE (1..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-write · current A textual description of the fuse monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CcurrentMonitorFuseTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.9.3.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CcurrentMonitorFuseAlarmEnable | 1.3.6.1.4.1.12148.10.13.9.3.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CcurrentMonitorFuseValue | 1.3.6.1.4.1.12148.10.13.9.3.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured fuse value. | |||||||||||||||||||||
| TcurrentMonitorCurrentTable | 1.3.6.1.4.1.12148.10.13.9.4 | NA | |||||||||||||||||||
| RcurrentMonitorCurrentEntry | 1.3.6.1.4.1.12148.10.13.9.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcurrentMonitorCurrentIndex | 1.3.6.1.4.1.12148.10.13.9.4.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current Index used for navigating the rows of currentMonitorCurrentTable The size of the table is defined by the currentMonitorNumberOfCurrents | |||||||||||||||||||||
| CcurrentMonitorCurrentStatus | 1.3.6.1.4.1.12148.10.13.9.4.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of current in current monitor
| |||||||||||||||||||||
| CcurrentMonitorCurrentDescription | 1.3.6.1.4.1.12148.10.13.9.4.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the current monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CcurrentMonitorCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.9.4.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CcurrentMonitorCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.13.9.4.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CcurrentMonitorCurrentValue | 1.3.6.1.4.1.12148.10.13.9.4.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured current value. | |||||||||||||||||||||
| CcurrentMonitorCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.9.4.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CcurrentMonitorCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.9.4.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TcurrentMonitorEnergyLogAccumulatedTable | 1.3.6.1.4.1.12148.10.13.9.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the accumulated energy consumption measured in current monitor | |||||||||||||||||||||
| RcurrentMonitorEnergyLogAccumulatedEntry | 1.3.6.1.4.1.12148.10.13.9.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcurrentMonitorEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.13.9.5.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The accumulated energy consumption value | |||||||||||||||||||||
| ScurrentMonitorEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.13.9.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in hourly energy log | |||||||||||||||||||||
| TcurrentMonitorEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.13.9.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains energy consumption values logged every hour in current monitor. | |||||||||||||||||||||
| RcurrentMonitorEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.13.9.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcurrentMonitorEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.13.9.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of currentMonitorEnergyLogLastHoursTable | |||||||||||||||||||||
| CcurrentMonitorEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.13.9.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy consumption value logged every hour in current monitor. | |||||||||||||||||||||
| ScurrentMonitorEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.13.9.8 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in daily energy log | |||||||||||||||||||||
| TcurrentMonitorEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.13.9.9 | NA | |||||||||||||||||||
table · not-accessible · current This table contains energy consumption values logged every day in current monitor. | |||||||||||||||||||||
| RcurrentMonitorEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.13.9.9.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcurrentMonitorEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.13.9.9.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of currentMonitorEnergyLogLastDaysTable | |||||||||||||||||||||
| CcurrentMonitorEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.13.9.9.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy consumption value logged every day in current monitor. | |||||||||||||||||||||
| ScurrentMonitorEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.13.9.10 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in weekly energy log | |||||||||||||||||||||
| TcurrentMonitorEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.13.9.11 | NA | |||||||||||||||||||
table · not-accessible · current This table contains energy consumption values logged every week in current monitor. | |||||||||||||||||||||
| RcurrentMonitorEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.13.9.11.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CcurrentMonitorEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.13.9.11.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of currentMonitorEnergyLogLastWeekTable | |||||||||||||||||||||
| CcurrentMonitorEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.13.9.11.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy consumption value logged every week in current monitor. | |||||||||||||||||||||
| NflexiMonitors | 1.3.6.1.4.1.12148.10.13.10 | ||||||||||||||||||||
| SflexiMonitorsNumberOfUnits | 1.3.6.1.4.1.12148.10.13.10.1 | Integer32 (0..14) | RW | ||||||||||||||||||
scalar · Integer32 (0..14) · read-write · current This is the number of fleximonitors installed in the system. | |||||||||||||||||||||
| TflexiMonitorsTable | 1.3.6.1.4.1.12148.10.13.10.2 | NA | |||||||||||||||||||
| RflexiMonitorsEntry | 1.3.6.1.4.1.12148.10.13.10.2.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CflexiMonitorIndex | 1.3.6.1.4.1.12148.10.13.10.2.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of flexiMonitorsTable The size of the table is defined by the system | |||||||||||||||||||||
| CflexiMonitorType | 1.3.6.1.4.1.12148.10.13.10.2.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This shows if the fleximonitor is configured as battery monitor (1), load monitor (2), rectifier monitor (3), controller monitor(4), dcdc monitor (5), solar monitor (6), wind monitor (7) or fuel cell monitor 8).
| |||||||||||||||||||||
| CflexiMonitorId | 1.3.6.1.4.1.12148.10.13.10.2.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the unit index for each fleximonitor type. | |||||||||||||||||||||
| CflexiMonitorNumberOfInputs | 1.3.6.1.4.1.12148.10.13.10.2.1.4 | Integer32 (0..8) | RO | ||||||||||||||||||
column · Integer32 (0..8) · read-only · current Number of inputs in fleximonitor. | |||||||||||||||||||||
| CflexiMonitorNumberOfOutputs | 1.3.6.1.4.1.12148.10.13.10.2.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of outputs in fleximonitor. | |||||||||||||||||||||
| TflexiMonitorInputTable | 1.3.6.1.4.1.12148.10.13.10.3 | NA | |||||||||||||||||||
| RflexiMonitorInputEntry | 1.3.6.1.4.1.12148.10.13.10.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CflexiMonitorInputIndex | 1.3.6.1.4.1.12148.10.13.10.3.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Index used for navigating the rows of flexiMonitorInputTable The size of the table is defined by the flexiMonitorNumberOfInputs | |||||||||||||||||||||
| CflexiMonitorInputStatus | 1.3.6.1.4.1.12148.10.13.10.3.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Programmable input status.
| |||||||||||||||||||||
| CflexiMonitorInputDescription | 1.3.6.1.4.1.12148.10.13.10.3.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the programmable input. This is stored in the system controller and can be changed by the user. . | |||||||||||||||||||||
| CflexiMonitorInputTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.10.3.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CflexiMonitorInputAlarmEnable | 1.3.6.1.4.1.12148.10.13.10.3.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This will enable or disable this inputs Alarm functionality. Setting 'disabled' here will turn off lock the status to 'disabled' state
| |||||||||||||||||||||
| CflexiMonitorInputValue | 1.3.6.1.4.1.12148.10.13.10.3.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The inputs measured Value. Depending on the type of input, this may represent a Voltage, a Temperature, a Current, a Speed or a Boolean value. | |||||||||||||||||||||
| CflexiMonitorInputConfiguration | 1.3.6.1.4.1.12148.10.13.10.3.1.7 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Configuration of the input type. Available configurations are: ProgIn-Normally Open(1), ProgIn-Normally Closed(2), Voltage(3), Temperature(4),Current(5),Speed(6),Fuse-Normally Open(7),Fuse-Normally Closed(8), Fuse-Diode Matrix(9).
| |||||||||||||||||||||
| TflexiMonitorOutputTable | 1.3.6.1.4.1.12148.10.13.10.4 | NA | |||||||||||||||||||
| RflexiMonitorOutputEntry | 1.3.6.1.4.1.12148.10.13.10.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CflexiMonitorOutputIndex | 1.3.6.1.4.1.12148.10.13.10.4.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Index used for navigating the rows of flexiMonitorOutputTable The size of the table is defined by the flexiMonitorNumberOfOutputs | |||||||||||||||||||||
| CflexiMonitorOutputStatus | 1.3.6.1.4.1.12148.10.13.10.4.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current General output relays may be 'energized' or 'not energized'. 'energized' and 'not energized' correspond to normal and alarm condition respectively for normally activated configuration. Latched contactors may have values 'disconnected' or 'connected'
| |||||||||||||||||||||
| CflexiMonitorOutputDescription | 1.3.6.1.4.1.12148.10.13.10.4.1.3 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current A textual description of the output. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| NmainControlUnits | 1.3.6.1.4.1.12148.10.13.11 | ||||||||||||||||||||
| TmainControlUnitsTable | 1.3.6.1.4.1.12148.10.13.11.1 | NA | |||||||||||||||||||
| RmainControlUnitsEntry | 1.3.6.1.4.1.12148.10.13.11.1.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainControlUnitIndex | 1.3.6.1.4.1.12148.10.13.11.1.1.1 | Integer32 (1..14) | NA | ||||||||||||||||||
column · Integer32 (1..14) · not-accessible · current Index used for navigating the rows of controlUnitTable The size of the table is defined by the system | |||||||||||||||||||||
| CmainControlUnitNumberOfTemperatures | 1.3.6.1.4.1.12148.10.13.11.1.1.2 | Integer32 (1..14) | RO | ||||||||||||||||||
column · Integer32 (1..14) · read-only · current Total number of temperature measurements in main controller | |||||||||||||||||||||
| TmainControlUnitTemperatureTable | 1.3.6.1.4.1.12148.10.13.11.2 | NA | |||||||||||||||||||
| RmainControlUnitTemperatureEntry | 1.3.6.1.4.1.12148.10.13.11.2.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CmainControlUnitTemperatureIndex | 1.3.6.1.4.1.12148.10.13.11.2.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the temperature input table. The size of the table is defined by the batteryBankNumberOfTemp | |||||||||||||||||||||
| CmainControlUnitTemperatureStatus | 1.3.6.1.4.1.12148.10.13.11.2.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of battery temperature monitor
| |||||||||||||||||||||
| CmainControlUnitTemperatureDescription | 1.3.6.1.4.1.12148.10.13.11.2.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery temperature monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CmainControlUnitTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.11.2.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CmainControlUnitTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.13.11.2.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CmainControlUnitTemperatureValue | 1.3.6.1.4.1.12148.10.13.11.2.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured battery temperature. | |||||||||||||||||||||
| CmainControlUnitTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.13.11.2.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CmainControlUnitTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.13.11.2.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CmainControlUnitTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.13.11.2.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CmainControlUnitTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.13.11.2.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| TmainControlUnitEarthFaultTable | 1.3.6.1.4.1.12148.10.13.11.3 | NA | |||||||||||||||||||
| RmainControlUnitEarthFaultEntry | 1.3.6.1.4.1.12148.10.13.11.3.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CmainControlUnitEarthFaultStatus | 1.3.6.1.4.1.12148.10.13.11.3.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This status value shows if the earth resistance is lower than the defined alarm level.
| |||||||||||||||||||||
| CmainControlUnitEarthFaultDescription | 1.3.6.1.4.1.12148.10.13.11.3.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the earth fault monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CmainControlUnitEarthFaultTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.11.3.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CmainControlUnitEarthFaultAlarmEnable | 1.3.6.1.4.1.12148.10.13.11.3.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CmainControlUnitEarthFaultValue | 1.3.6.1.4.1.12148.10.13.11.3.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured value of the earth resistance in kOhm. | |||||||||||||||||||||
| CmainControlUnitEarthFaultMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.11.3.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| NcontrolSystemSummary | 1.3.6.1.4.1.12148.10.13.12 | ||||||||||||||||||||
| NmainControlUnitsError | 1.3.6.1.4.1.12148.10.13.12.1 | ||||||||||||||||||||
| SmainControlUnitsErrorStatus | 1.3.6.1.4.1.12148.10.13.12.1.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed main controllers is higher than the defined alarm level.
| |||||||||||||||||||||
| SmainControlUnitsErrorDescription | 1.3.6.1.4.1.12148.10.13.12.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the main control units error monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SmainControlUnitsErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.12.1.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SmainControlUnitsErrorAlarmEnable | 1.3.6.1.4.1.12148.10.13.12.1.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SmainControlUnitsErrorValue | 1.3.6.1.4.1.12148.10.13.12.1.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed main controllers. | |||||||||||||||||||||
| SmainControlUnitsErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.1.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SmainControlUnitsErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.1.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NsmartNodeError | 1.3.6.1.4.1.12148.10.13.12.2 | ||||||||||||||||||||
| SsmartNodeErrorStatus | 1.3.6.1.4.1.12148.10.13.12.2.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed smartnodes is higher than the defined alarm level.
| |||||||||||||||||||||
| SsmartNodeErrorDescription | 1.3.6.1.4.1.12148.10.13.12.2.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the smartnode error monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SsmartNodeErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.12.2.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SsmartNodeErrorAlarmEnable | 1.3.6.1.4.1.12148.10.13.12.2.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SsmartNodeErrorValue | 1.3.6.1.4.1.12148.10.13.12.2.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed smartnodes. | |||||||||||||||||||||
| SsmartNodeErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.2.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SsmartNodeErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.2.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NbatteryMonitorError | 1.3.6.1.4.1.12148.10.13.12.3 | ||||||||||||||||||||
| SbatteryMonitorErrorStatus | 1.3.6.1.4.1.12148.10.13.12.3.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed battery monitors is higher than the defined alarm level.
| |||||||||||||||||||||
| SbatteryMonitorErrorDescription | 1.3.6.1.4.1.12148.10.13.12.3.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery monitor error monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryMonitorErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.12.3.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryMonitorErrorAlarmEnable | 1.3.6.1.4.1.12148.10.13.12.3.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryMonitorErrorValue | 1.3.6.1.4.1.12148.10.13.12.3.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed battery monitors. | |||||||||||||||||||||
| SbatteryMonitorErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.3.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SbatteryMonitorErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.3.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NloadMonitorError | 1.3.6.1.4.1.12148.10.13.12.4 | ||||||||||||||||||||
| SloadMonitorErrorStatus | 1.3.6.1.4.1.12148.10.13.12.4.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed load monitors is higher than the defined alarm level.
| |||||||||||||||||||||
| SloadMonitorErrorDescription | 1.3.6.1.4.1.12148.10.13.12.4.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the load monitor error monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SloadMonitorErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.12.4.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SloadMonitorErrorAlarmEnable | 1.3.6.1.4.1.12148.10.13.12.4.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SloadMonitorErrorValue | 1.3.6.1.4.1.12148.10.13.12.4.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed load monitors. | |||||||||||||||||||||
| SloadMonitorErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.4.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SloadMonitorErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.4.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NioUnitError | 1.3.6.1.4.1.12148.10.13.12.5 | ||||||||||||||||||||
| SioUnitErrorStatus | 1.3.6.1.4.1.12148.10.13.12.5.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed IO units is higher than the defined alarm level.
| |||||||||||||||||||||
| SioUnitErrorDescription | 1.3.6.1.4.1.12148.10.13.12.5.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the IO unit error monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SioUnitErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.12.5.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SioUnitErrorAlarmEnable | 1.3.6.1.4.1.12148.10.13.12.5.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SioUnitErrorValue | 1.3.6.1.4.1.12148.10.13.12.5.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed IO units. | |||||||||||||||||||||
| SioUnitErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.5.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SioUnitErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.5.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NmainsMonitorError | 1.3.6.1.4.1.12148.10.13.12.6 | ||||||||||||||||||||
| SmainsMonitorErrorStatus | 1.3.6.1.4.1.12148.10.13.12.6.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed mains monitors is higher than the defined alarm level.
| |||||||||||||||||||||
| SmainsMonitorErrorDescription | 1.3.6.1.4.1.12148.10.13.12.6.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the mains monitor error monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SmainsMonitorErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.12.6.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SmainsMonitorErrorAlarmEnable | 1.3.6.1.4.1.12148.10.13.12.6.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SmainsMonitorErrorValue | 1.3.6.1.4.1.12148.10.13.12.6.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed mains monitors. | |||||||||||||||||||||
| SmainsMonitorErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.6.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SmainsMonitorErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.6.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NflexiMonitorError | 1.3.6.1.4.1.12148.10.13.12.7 | ||||||||||||||||||||
| SflexiMonitorErrorStatus | 1.3.6.1.4.1.12148.10.13.12.7.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed flexi monitors is higher than the defined alarm level.
| |||||||||||||||||||||
| SflexiMonitorErrorDescription | 1.3.6.1.4.1.12148.10.13.12.7.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the flexi monitor error monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SflexiMonitorErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.12.7.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SflexiMonitorErrorAlarmEnable | 1.3.6.1.4.1.12148.10.13.12.7.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SflexiMonitorErrorValue | 1.3.6.1.4.1.12148.10.13.12.7.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed flexi monitors. | |||||||||||||||||||||
| SflexiMonitorErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.7.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SflexiMonitorErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.13.12.7.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NambientTemperature | 1.3.6.1.4.1.12148.10.13.13 | ||||||||||||||||||||
| SambientTemperatureStatus | 1.3.6.1.4.1.12148.10.13.13.1 | INTEGER | RO | disabled(4) | |||||||||||||||||
scalar · INTEGER · read-only · current The state of the ambient temperature can be either one of the defined enumerated values
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SambientTemperatureDescription | 1.3.6.1.4.1.12148.10.13.13.2 | DisplayString (SIZE (0..16)) | RW | AmbientTemp | |||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the ambient temperature monitor. This is stored in the system controller and can be changed by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SambientTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.13.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SambientTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.13.13.4 | INTEGER | RW | disabled(0) | |||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SambientTemperatureValue | 1.3.6.1.4.1.12148.10.13.13.5 | Integer32 (0..9999) | RO | 0 | |||||||||||||||||
scalar · Integer32 (0..9999) · read-only · current The highest value of the enabled ambient temperature measurements. Depending on the global setting in the Control unit, this value will be presented in Celsius or Fahrenheit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SambientTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.13.13.6 | Integer32 | RW | 40 | |||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SambientTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.13.13.7 | Integer32 | RW | 30 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SambientTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.13.13.8 | Integer32 | RW | -5 | |||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SambientTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.13.13.9 | Integer32 | RW | -10 | |||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit Example values from LibreNMS test devices
| |||||||||||||||||||||
| NdeltaTemperature | 1.3.6.1.4.1.12148.10.13.14 | ||||||||||||||||||||
| SdeltaTemperatureStatus | 1.3.6.1.4.1.12148.10.13.14.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The state of the delta temperature can be either one of the defined enumerated values
| |||||||||||||||||||||
| SdeltaTemperatureDescription | 1.3.6.1.4.1.12148.10.13.14.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the delta temperature monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SdeltaTemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.14.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SdeltaTemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.13.14.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SdeltaTemperatureValue | 1.3.6.1.4.1.12148.10.13.14.5 | Integer32 (0..9999) | RO | ||||||||||||||||||
scalar · Integer32 (0..9999) · read-only · current The delta temperature value. Depending on the global setting in the Control unit, this value will be presented in Celsius or Fahrenheit. | |||||||||||||||||||||
| SdeltaTemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.13.14.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| SdeltaTemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.13.14.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| SdeltaTemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.13.14.8 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| SdeltaTemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.13.14.9 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| NuserSuspended | 1.3.6.1.4.1.12148.10.13.15 | ||||||||||||||||||||
| SuserSuspendedStatus | 1.3.6.1.4.1.12148.10.13.15.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed attempts is higher than the defined alarm level.
| |||||||||||||||||||||
| SuserSuspendedDescription | 1.3.6.1.4.1.12148.10.13.15.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the login failure monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SuserSuspendedTrapRepeatCounter | 1.3.6.1.4.1.12148.10.13.15.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SuserSuspendedAlarmEnable | 1.3.6.1.4.1.12148.10.13.15.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SuserSuspendedValue | 1.3.6.1.4.1.12148.10.13.15.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The detected number of failed attempts. | |||||||||||||||||||||
| SuserSuspendedMajorAlarmLevel | 1.3.6.1.4.1.12148.10.13.15.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| NalarmGroups | 1.3.6.1.4.1.12148.10.14 | ||||||||||||||||||||
| TalarmGroupTable | 1.3.6.1.4.1.12148.10.14.1 | NA | |||||||||||||||||||
| RalarmGroupEntry | 1.3.6.1.4.1.12148.10.14.1.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CalarmGroupIndex | 1.3.6.1.4.1.12148.10.14.1.1.1 | Integer32 (1..49) | NA | ||||||||||||||||||
column · Integer32 (1..49) · not-accessible · current Index used for navigating the rows 1..49 of alarmGroupTable | |||||||||||||||||||||
| CalarmGroupStatus | 1.3.6.1.4.1.12148.10.14.1.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of alarm group
| |||||||||||||||||||||
| CalarmGroupDescription | 1.3.6.1.4.1.12148.10.14.1.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the alarm group. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| NbatteryGroup2 | 1.3.6.1.4.1.12148.10.15 | ||||||||||||||||||||
| SbatteryGroup2Status | 1.3.6.1.4.1.12148.10.15.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current A toplevel status for the battery group 2.The state of this reflects the status of all underlying statuses for the battery. Any change in one of the 'data monitors' in the battery subsystem will propagate up to this status indicator.
| |||||||||||||||||||||
| SbatteryGroup2Description | 1.3.6.1.4.1.12148.10.15.2 | DisplayString (SIZE (0..32)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..32)) · read-write · current A descriptive name of the battery installed in the battery group 2. | |||||||||||||||||||||
| SbatteryGroup2ReferenceVoltage | 1.3.6.1.4.1.12148.10.15.3 | Integer32 (840..60417) | RW | ||||||||||||||||||
scalar · Integer32 (840..60417) · read-write · current The reference voltage of battery group 2. | |||||||||||||||||||||
| SbatteryGroup2FusesStatus | 1.3.6.1.4.1.12148.10.15.4 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The state of the battery fuses/breakers can mainly be normal(1) or majorAlarm(3) and some other rarely used values .
| |||||||||||||||||||||
| NbatteryGroup2Voltage | 1.3.6.1.4.1.12148.10.15.5 | ||||||||||||||||||||
| SbatteryGroup2VoltageStatus | 1.3.6.1.4.1.12148.10.15.5.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured battery voltage.
| |||||||||||||||||||||
| SbatteryGroup2VoltageDescription | 1.3.6.1.4.1.12148.10.15.5.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery voltage monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryGroup2VoltageTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.5.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryGroup2VoltageAlarmEnable | 1.3.6.1.4.1.12148.10.15.5.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current The measured battery voltage alarm enable/disable control
| |||||||||||||||||||||
| SbatteryGroup2VoltageValue | 1.3.6.1.4.1.12148.10.15.5.5 | Integer32 (0..7500) | RO | ||||||||||||||||||
scalar · Integer32 (0..7500) · read-only · current The value of the measured battery voltage. | |||||||||||||||||||||
| SbatteryGroup2VoltageMajorHighLevel | 1.3.6.1.4.1.12148.10.15.5.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The Major High Battery Voltage alarm limit set voltage | |||||||||||||||||||||
| SbatteryGroup2VoltageMinorHighLevel | 1.3.6.1.4.1.12148.10.15.5.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The Minor High Battery Voltage alarm limit set voltage | |||||||||||||||||||||
| SbatteryGroup2VoltageMinorLowLevel | 1.3.6.1.4.1.12148.10.15.5.8 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The Minor Low Battery Voltage alarm limit set voltage | |||||||||||||||||||||
| SbatteryGroup2VoltageMajorLowLevel | 1.3.6.1.4.1.12148.10.15.5.9 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The Major Low Battery Voltage alarm limit set voltage | |||||||||||||||||||||
| NbatteryGroup2Currents | 1.3.6.1.4.1.12148.10.15.6 | ||||||||||||||||||||
| SbatteryGroup2CurrentsStatus | 1.3.6.1.4.1.12148.10.15.6.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured battery current
| |||||||||||||||||||||
| SbatteryGroup2CurrentsDescription | 1.3.6.1.4.1.12148.10.15.6.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery current monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryGroup2CurrentsTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.6.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryGroup2CurrentsAlarmEnable | 1.3.6.1.4.1.12148.10.15.6.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2CurrentsValue | 1.3.6.1.4.1.12148.10.15.6.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The measured total battery current. This is the sum of all the enabled shunt measurements in the system. Negative battery current indicates discharging of the batteries. Positive battery current indicates charging of the batteries. Note that the units measured may be i Amperes or in Deciamperes depending on global system settings | |||||||||||||||||||||
| SbatteryGroup2CurrentsMajorHighLevel | 1.3.6.1.4.1.12148.10.15.6.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| SbatteryGroup2CurrentsMinorHighLevel | 1.3.6.1.4.1.12148.10.15.6.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| SbatteryGroup2CurrentsMinorLowLevel | 1.3.6.1.4.1.12148.10.15.6.8 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| SbatteryGroup2CurrentsMajorLowLevel | 1.3.6.1.4.1.12148.10.15.6.9 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| NbatteryGroup2Temperatures | 1.3.6.1.4.1.12148.10.15.7 | ||||||||||||||||||||
| SbatteryGroup2TemperaturesStatus | 1.3.6.1.4.1.12148.10.15.7.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The state of the battery fuses/breakers can be either one of the defined enumerated values
| |||||||||||||||||||||
| SbatteryGroup2TemperaturesDescription | 1.3.6.1.4.1.12148.10.15.7.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery temperature monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryGroup2TemperaturesTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.7.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryGroup2TemperaturesAlarmEnable | 1.3.6.1.4.1.12148.10.15.7.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2TemperaturesValue | 1.3.6.1.4.1.12148.10.15.7.5 | Integer32 (0..9999) | RO | ||||||||||||||||||
scalar · Integer32 (0..9999) · read-only · current The highest value of the enabled battery temperature measurements. Depending on the global setting in the Control unit, this value will be presented in Celsius or Fahrenheit. | |||||||||||||||||||||
| SbatteryGroup2TemperaturesMajorHighLevel | 1.3.6.1.4.1.12148.10.15.7.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| SbatteryGroup2TemperaturesMinorHighLevel | 1.3.6.1.4.1.12148.10.15.7.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| SbatteryGroup2TemperaturesMinorLowLevel | 1.3.6.1.4.1.12148.10.15.7.8 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| SbatteryGroup2TemperaturesMajorLowLevel | 1.3.6.1.4.1.12148.10.15.7.9 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| NbatteryGroup2TimeLeft | 1.3.6.1.4.1.12148.10.15.8 | ||||||||||||||||||||
| SbatteryGroup2TimeLeftStatus | 1.3.6.1.4.1.12148.10.15.8.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the estimated battery remaining backup time.
| |||||||||||||||||||||
| SbatteryGroup2TimeLeftDescription | 1.3.6.1.4.1.12148.10.15.8.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery discharge time monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryGroup2TimeLeftTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.8.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryGroup2TimeLeftAlarmEnable | 1.3.6.1.4.1.12148.10.15.8.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2TimeLeftValue | 1.3.6.1.4.1.12148.10.15.8.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The estimated value of battery remaining backup time. | |||||||||||||||||||||
| SbatteryGroup2TimeLeftMinorAlarmLevel | 1.3.6.1.4.1.12148.10.15.8.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| SbatteryGroup2TimeLeftMajorAlarmLevel | 1.3.6.1.4.1.12148.10.15.8.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| NbatteryGroup2RemainingCapacity | 1.3.6.1.4.1.12148.10.15.9 | ||||||||||||||||||||
| SbatteryGroup2RemainingCapacityStatus | 1.3.6.1.4.1.12148.10.15.9.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery remaining capacity monitor.
| |||||||||||||||||||||
| SbatteryGroup2RemainingCapacityDescription | 1.3.6.1.4.1.12148.10.15.9.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery remaining capacity monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryGroup2RemainingCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.9.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryGroup2RemainingCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.15.9.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2RemainingCapacityValue | 1.3.6.1.4.1.12148.10.15.9.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Battery remaining capacity (SOC) value estimated from the latest battery test result. | |||||||||||||||||||||
| SbatteryGroup2RemainingCapacityMinorLowLevel | 1.3.6.1.4.1.12148.10.15.9.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| SbatteryGroup2RemainingCapacityMajorLowLevel | 1.3.6.1.4.1.12148.10.15.9.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| NbatteryGroup2UsedCapacity | 1.3.6.1.4.1.12148.10.15.10 | ||||||||||||||||||||
| SbatteryGroup2UsedCapacityStatus | 1.3.6.1.4.1.12148.10.15.10.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery used capacity (DoD) monitor
| |||||||||||||||||||||
| SbatteryGroup2UsedCapacityDescription | 1.3.6.1.4.1.12148.10.15.10.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery used capacity (DoD) monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryGroup2UsedCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.10.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryGroup2UsedCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.15.10.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2UsedCapacityValue | 1.3.6.1.4.1.12148.10.15.10.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the estimated battery used capacity (DoD). | |||||||||||||||||||||
| SbatteryGroup2UsedCapacityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.15.10.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SbatteryGroup2UsedCapacityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.15.10.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NbatteryGroup2TotalCapacity | 1.3.6.1.4.1.12148.10.15.11 | ||||||||||||||||||||
| SbatteryGroup2TotalCapacityStatus | 1.3.6.1.4.1.12148.10.15.11.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the total capacity monitor.
| |||||||||||||||||||||
| SbatteryGroup2TotalCapacityDescription | 1.3.6.1.4.1.12148.10.15.11.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery total capacity monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SbatteryGroup2TotalCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.11.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryGroup2TotalCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.15.11.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2TotalCapacityValue | 1.3.6.1.4.1.12148.10.15.11.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the estimated total battery capacity (installed Ah - SoH) value. | |||||||||||||||||||||
| SbatteryGroup2TotalCapacityMinorLowLevel | 1.3.6.1.4.1.12148.10.15.11.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| SbatteryGroup2TotalCapacityMajorLowLevel | 1.3.6.1.4.1.12148.10.15.11.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| NbatteryGroup2Quality | 1.3.6.1.4.1.12148.10.15.12 | ||||||||||||||||||||
| SbatteryGroup2QualityStatus | 1.3.6.1.4.1.12148.10.15.12.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery quality (SoH) monitor.
| |||||||||||||||||||||
| SbatteryGroup2QualityDescription | 1.3.6.1.4.1.12148.10.15.12.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery quality (SoH) monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SbatteryGroup2QualityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.12.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryGroup2QualityAlarmEnable | 1.3.6.1.4.1.12148.10.15.12.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2QualityValue | 1.3.6.1.4.1.12148.10.15.12.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The calculated battery quality (SoH) based on the latest battery test | |||||||||||||||||||||
| SbatteryGroup2QualityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.15.12.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| SbatteryGroup2QualityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.15.12.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| NbatteryGroup2LVBD | 1.3.6.1.4.1.12148.10.15.13 | ||||||||||||||||||||
| SbatteryGroup2LVBDStatus | 1.3.6.1.4.1.12148.10.15.13.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The Battery Contactor is connected, disconnected, disabled or in any other alarm condition
| |||||||||||||||||||||
| SbatteryGroup2LVBDDescription | 1.3.6.1.4.1.12148.10.15.13.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery LVBD monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| SbatteryGroup2LVBDTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.13.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| SbatteryGroup2LVBDEnable | 1.3.6.1.4.1.12148.10.15.13.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the LVBD will be reported.
| |||||||||||||||||||||
| SbatteryGroup2LVBDValue | 1.3.6.1.4.1.12148.10.15.13.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The measured value of the LVBD. | |||||||||||||||||||||
| SbatteryGroup2LVBDConnectVoltage | 1.3.6.1.4.1.12148.10.15.13.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The Battery Contactor's Reconnect Voltage | |||||||||||||||||||||
| SbatteryGroup2LVBDDisconnectVoltage | 1.3.6.1.4.1.12148.10.15.13.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The Battery Contactor's Disconnect Voltage | |||||||||||||||||||||
| NbatteryGroup2ChargeCurrentLimit | 1.3.6.1.4.1.12148.10.15.14 | ||||||||||||||||||||
| SbatteryGroup2ChargeCurrentLimitEnable | 1.3.6.1.4.1.12148.10.15.14.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable of the battery charge current limitation feature; 0=disable, 1=enable.
| |||||||||||||||||||||
| SbatteryGroup2ChargeCurrentLimitValue | 1.3.6.1.4.1.12148.10.15.14.2 | Integer32 (0..32767) | RW | ||||||||||||||||||
scalar · Integer32 (0..32767) · read-write · current Battery charging current limit value. Used only when AC source is mains feed. Note that the units measured may be i Amperes or in Deciamperes depending on global system settings | |||||||||||||||||||||
| NbatteryGroup2Boost | 1.3.6.1.4.1.12148.10.15.15 | ||||||||||||||||||||
| SbatteryGroup2BoostVoltage | 1.3.6.1.4.1.12148.10.15.15.1 | Integer32 (870..60418) | RW | ||||||||||||||||||
scalar · Integer32 (870..60418) · read-write · current The Voltage at which the DC System boost charges the batteries. | |||||||||||||||||||||
| SbatteryGroup2BoostCommand | 1.3.6.1.4.1.12148.10.15.15.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This pushbutton will start or stop a manual battery boost if the system allows it.
| |||||||||||||||||||||
| SbatteryGroup2BoostCurrentThreshold | 1.3.6.1.4.1.12148.10.15.15.3 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The boosting will terminate when the charge current drops below the BoostCurrentThreshold limit. | |||||||||||||||||||||
| SbatteryGroup2BoostManualMaxDuration | 1.3.6.1.4.1.12148.10.15.15.4 | Integer32 (0..1440) | RW | ||||||||||||||||||
scalar · Integer32 (0..1440) · read-write · current A protection against overcharging. When running manual boost, the boosting will always terminate at this point. | |||||||||||||||||||||
| NbatteryGroup2Test | 1.3.6.1.4.1.12148.10.15.16 | ||||||||||||||||||||
| SbatteryGroup2TestVoltage | 1.3.6.1.4.1.12148.10.15.16.1 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current This is the battery test end voltage. The battery test will be terminated when the voltage drops below the end voltage. | |||||||||||||||||||||
| SbatteryGroup2TestCommand | 1.3.6.1.4.1.12148.10.15.16.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This pushbutton will start or stop a manual battery test if the system allows it.
| |||||||||||||||||||||
| SbatteryGroup2TestNumberOfResults | 1.3.6.1.4.1.12148.10.15.16.3 | Integer32 (0..10) | RO | ||||||||||||||||||
scalar · Integer32 (0..10) · read-only · current This is the number of valid battery test results stored in controller. | |||||||||||||||||||||
| TbatteryGroup2TestResultTable | 1.3.6.1.4.1.12148.10.15.16.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the battery test results stored in controller. | |||||||||||||||||||||
| RbatteryGroup2TestResultEntry | 1.3.6.1.4.1.12148.10.15.16.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2TestResultIndex | 1.3.6.1.4.1.12148.10.15.16.4.1.1 | Integer32 (1..10) | NA | ||||||||||||||||||
column · Integer32 (1..10) · not-accessible · current A index pointing to one of ten possible battery test results | |||||||||||||||||||||
| CbatteryGroup2TestResultStartDateTime | 1.3.6.1.4.1.12148.10.15.16.4.1.2 | DateAndTime | RO | ||||||||||||||||||
column · DateAndTime · read-only · current This is the time and date when the test started. | |||||||||||||||||||||
| CbatteryGroup2TestResultDuration | 1.3.6.1.4.1.12148.10.15.16.4.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the test duration in minutes. | |||||||||||||||||||||
| CbatteryGroup2TestResultDischarged | 1.3.6.1.4.1.12148.10.15.16.4.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the discharged Ah during test. | |||||||||||||||||||||
| CbatteryGroup2TestResultQuality | 1.3.6.1.4.1.12148.10.15.16.4.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the calculated battery quality (SoH)in percentage. | |||||||||||||||||||||
| NbatteryGroup2TempComp | 1.3.6.1.4.1.12148.10.15.17 | ||||||||||||||||||||
| SbatteryGroup2TempCompEnable | 1.3.6.1.4.1.12148.10.15.17.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable (1) or Disable (0) of Battery Temperature Compensated output regulation mode
| |||||||||||||||||||||
| NbatteryGroup2Bank | 1.3.6.1.4.1.12148.10.15.18 | ||||||||||||||||||||
| SbatteryGroup2BankStatus | 1.3.6.1.4.1.12148.10.15.18.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The overall status of battery bank
| |||||||||||||||||||||
| SbatteryGroup2BankNumberOfTemperatures | 1.3.6.1.4.1.12148.10.15.18.2 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Number of temperature measurements in battery bank. | |||||||||||||||||||||
| SbatteryGroup2BankNumberOfCurrents | 1.3.6.1.4.1.12148.10.15.18.3 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Number of current measurements in battery bank. | |||||||||||||||||||||
| SbatteryGroup2BankNumberOfFuses | 1.3.6.1.4.1.12148.10.15.18.4 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Number of fuses installed in battery bank. | |||||||||||||||||||||
| SbatteryGroup2BankNumberOfSymmetries | 1.3.6.1.4.1.12148.10.15.18.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Number of fuses installed in battery bank. | |||||||||||||||||||||
| TbatteryGroup2BankTemperatureTable | 1.3.6.1.4.1.12148.10.15.18.6 | NA | |||||||||||||||||||
| RbatteryGroup2BankTemperatureEntry | 1.3.6.1.4.1.12148.10.15.18.6.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2TemperatureIndex | 1.3.6.1.4.1.12148.10.15.18.6.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the temperature input table. The size of the table is defined by the batteryGroup2BankNumberOfTemperatures | |||||||||||||||||||||
| CbatteryGroup2TemperatureStatus | 1.3.6.1.4.1.12148.10.15.18.6.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of battery temperature monitor
| |||||||||||||||||||||
| CbatteryGroup2TemperatureDescription | 1.3.6.1.4.1.12148.10.15.18.6.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery temperature monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CbatteryGroup2TemperatureTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.18.6.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CbatteryGroup2TemperatureAlarmEnable | 1.3.6.1.4.1.12148.10.15.18.6.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CbatteryGroup2TemperatureValue | 1.3.6.1.4.1.12148.10.15.18.6.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured battery temperature. | |||||||||||||||||||||
| CbatteryGroup2TemperatureMajorHighLevel | 1.3.6.1.4.1.12148.10.15.18.6.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CbatteryGroup2TemperatureMinorHighLevel | 1.3.6.1.4.1.12148.10.15.18.6.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CbatteryGroup2TemperatureMinorLowLevel | 1.3.6.1.4.1.12148.10.15.18.6.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CbatteryGroup2TemperatureMajorLowLevel | 1.3.6.1.4.1.12148.10.15.18.6.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| TbatteryGroup2BankCurrentTable | 1.3.6.1.4.1.12148.10.15.18.7 | NA | |||||||||||||||||||
| RbatteryGroup2BankCurrentEntry | 1.3.6.1.4.1.12148.10.15.18.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2CurrentIndex | 1.3.6.1.4.1.12148.10.15.18.7.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the current input table. The size of the table is defined by the system | |||||||||||||||||||||
| CbatteryGroup2CurrentStatus | 1.3.6.1.4.1.12148.10.15.18.7.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of battery current monitor
| |||||||||||||||||||||
| CbatteryGroup2CurrentDescription | 1.3.6.1.4.1.12148.10.15.18.7.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery current monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CbatteryGroup2CurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.18.7.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CbatteryGroup2CurrentAlarmEnable | 1.3.6.1.4.1.12148.10.15.18.7.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CbatteryGroup2CurrentValue | 1.3.6.1.4.1.12148.10.15.18.7.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured battery current | |||||||||||||||||||||
| CbatteryGroup2CurrentMajorHighLevel | 1.3.6.1.4.1.12148.10.15.18.7.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| CbatteryGroup2CurrentMinorHighLevel | 1.3.6.1.4.1.12148.10.15.18.7.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| CbatteryGroup2CurrentMinorLowLevel | 1.3.6.1.4.1.12148.10.15.18.7.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor low alarm limit | |||||||||||||||||||||
| CbatteryGroup2CurrentMajorLowLevel | 1.3.6.1.4.1.12148.10.15.18.7.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major low alarm limit | |||||||||||||||||||||
| TbatteryGroup2BankFuseTable | 1.3.6.1.4.1.12148.10.15.18.8 | NA | |||||||||||||||||||
| RbatteryGroup2BankFuseEntry | 1.3.6.1.4.1.12148.10.15.18.8.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2FuseIndex | 1.3.6.1.4.1.12148.10.15.18.8.1.1 | Integer32 (1..4) | NA | ||||||||||||||||||
column · Integer32 (1..4) · not-accessible · current This index denotes which row in the fuse table. The size of the table is defined by the system | |||||||||||||||||||||
| CbatteryGroup2FuseStatus | 1.3.6.1.4.1.12148.10.15.18.8.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of battery fuse monitor
| |||||||||||||||||||||
| CbatteryGroup2FuseDescription | 1.3.6.1.4.1.12148.10.15.18.8.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery fuse monitor. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CbatteryGroup2FuseTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.18.8.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off. | |||||||||||||||||||||
| CbatteryGroup2FuseAlarmEnable | 1.3.6.1.4.1.12148.10.15.18.8.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CbatteryGroup2FuseValue | 1.3.6.1.4.1.12148.10.15.18.8.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured value of battery fuse input. | |||||||||||||||||||||
| TbatteryGroup2BankSymmetryTable | 1.3.6.1.4.1.12148.10.15.18.9 | NA | |||||||||||||||||||
| RbatteryGroup2BankSymmetryEntry | 1.3.6.1.4.1.12148.10.15.18.9.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2BankSymmetryIndex | 1.3.6.1.4.1.12148.10.15.18.9.1.1 | Integer32 (1..8) | NA | ||||||||||||||||||
column · Integer32 (1..8) · not-accessible · current This index denotes which row in the symmetry input table. The size of the table is defined by the batteryMonitorNumberOfSymmetries | |||||||||||||||||||||
| CbatteryGroup2BankSymmetryStatus | 1.3.6.1.4.1.12148.10.15.18.9.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of battery symmetry monitor
| |||||||||||||||||||||
| CbatteryGroup2BankSymmetryDescription | 1.3.6.1.4.1.12148.10.15.18.9.1.3 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery monitor symmetry. This is stored in the system controller and can be changed by the user. | |||||||||||||||||||||
| CbatteryGroup2BankSymmetryTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.18.9.1.4 | Counter32 | AN | ||||||||||||||||||
column · Counter32 · accessible-for-notify · current The number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CbatteryGroup2BankSymmetryAlarmEnable | 1.3.6.1.4.1.12148.10.15.18.9.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CbatteryGroup2BankSymmetryMeasureValue | 1.3.6.1.4.1.12148.10.15.18.9.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured battery symmetry voltage in battery monitor. | |||||||||||||||||||||
| CbatteryGroup2BankSymmetryDeltaValue | 1.3.6.1.4.1.12148.10.15.18.9.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured battery symmetry delta voltage in battery monitor. | |||||||||||||||||||||
| CbatteryGroup2BankSymmetryMajorAlarmLevel | 1.3.6.1.4.1.12148.10.15.18.9.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CbatteryGroup2BankSymmetryMinorAlarmLevel | 1.3.6.1.4.1.12148.10.15.18.9.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NbatteryGroup2EnergyLog | 1.3.6.1.4.1.12148.10.15.19 | ||||||||||||||||||||
| SbatteryGroup2EnergyLogAccumulated | 1.3.6.1.4.1.12148.10.15.19.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered to/from battery. | |||||||||||||||||||||
| SbatteryGroup2EnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.15.19.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in battery hourly energy log. | |||||||||||||||||||||
| TbatteryGroup2EnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.15.19.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of battery. | |||||||||||||||||||||
| RbatteryGroup2EnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.15.19.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2EnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.15.19.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryEnergyLogLastHoursTable | |||||||||||||||||||||
| CbatteryGroup2EnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.15.19.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. | |||||||||||||||||||||
| SbatteryGroup2EnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.15.19.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in battery daily energy log. | |||||||||||||||||||||
| TbatteryGroup2EnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.15.19.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of battery. | |||||||||||||||||||||
| RbatteryGroup2EnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.15.19.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2EnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.15.19.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryEnergyLogLastDaysTable | |||||||||||||||||||||
| CbatteryGroup2EnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.15.19.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. | |||||||||||||||||||||
| SbatteryGroup2EnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.15.19.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in battery weekly energy log. | |||||||||||||||||||||
| TbatteryGroup2EnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.15.19.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of battery. | |||||||||||||||||||||
| RbatteryGroup2EnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.15.19.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2EnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.15.19.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryEnergyLogLastWeekTable | |||||||||||||||||||||
| CbatteryGroup2EnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.15.19.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every week. | |||||||||||||||||||||
| NbatteryGroup2CycleLog | 1.3.6.1.4.1.12148.10.15.20 | ||||||||||||||||||||
| SbatteryGroup2CycleLogTotalCycles | 1.3.6.1.4.1.12148.10.15.20.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the total number of battery discharge cycles. | |||||||||||||||||||||
| SbatteryGroup2CycleLogDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.15.20.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in daily battery discharge cycle log. | |||||||||||||||||||||
| TbatteryGroup2CycleLogDaysTable | 1.3.6.1.4.1.12148.10.15.20.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily battery discharge cycle log. | |||||||||||||||||||||
| RbatteryGroup2CycleLogDaysEntry | 1.3.6.1.4.1.12148.10.15.20.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2CycleLogDaysIndex | 1.3.6.1.4.1.12148.10.15.20.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryCycleLogLastDaysTable | |||||||||||||||||||||
| CbatteryGroup2CycleLogDaysValue | 1.3.6.1.4.1.12148.10.15.20.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of discharge cycles logged every day. | |||||||||||||||||||||
| SbatteryGroup2CycleLogWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.15.20.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in weeky battery discharge cycle log. | |||||||||||||||||||||
| TbatteryGroup2CycleLogWeeksTable | 1.3.6.1.4.1.12148.10.15.20.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly battery discharge cycle log. | |||||||||||||||||||||
| RbatteryGroup2CycleLogWeeksEntry | 1.3.6.1.4.1.12148.10.15.20.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2CycleLogWeeksIndex | 1.3.6.1.4.1.12148.10.15.20.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryCycleLogLastWeeksTable | |||||||||||||||||||||
| CbatteryGroup2CycleLogWeeksValue | 1.3.6.1.4.1.12148.10.15.20.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of discharge cycles logged every week. | |||||||||||||||||||||
| SbatteryGroup2CycleLogMonthsNumberOfEntries | 1.3.6.1.4.1.12148.10.15.20.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in monthly battery discharge cycle log. | |||||||||||||||||||||
| TbatteryGroup2CycleLogMonthsTable | 1.3.6.1.4.1.12148.10.15.20.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains monthly battery discharge cycle log. | |||||||||||||||||||||
| RbatteryGroup2CycleLogMonthsEntry | 1.3.6.1.4.1.12148.10.15.20.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CbatteryGroup2CycleLogMonthsIndex | 1.3.6.1.4.1.12148.10.15.20.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of batteryCycleLogLastMonthTable | |||||||||||||||||||||
| CbatteryGroup2CycleLogMonthsValue | 1.3.6.1.4.1.12148.10.15.20.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of discharge cycles logged every month. | |||||||||||||||||||||
| NbatteryGroup2Equalize | 1.3.6.1.4.1.12148.10.15.21 | ||||||||||||||||||||
| SbatteryGroup2EqualizeVoltage | 1.3.6.1.4.1.12148.10.15.21.1 | Integer32 (870..60418) | RW | ||||||||||||||||||
scalar · Integer32 (870..60418) · read-write · current The Voltage at which the DC System equalize charges the batteries. | |||||||||||||||||||||
| SbatteryGroup2EqualizeCommand | 1.3.6.1.4.1.12148.10.15.21.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This pushbutton will start or stop a manual battery equalize if the system allows it.
| |||||||||||||||||||||
| SbatteryGroup2EqualizeCurrentThreshold | 1.3.6.1.4.1.12148.10.15.21.3 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The equalizing will terminate when the charge current drops below the EqualizeCurrentThreshold limit. | |||||||||||||||||||||
| SbatteryGroup2EqualizeManualMaxDuration | 1.3.6.1.4.1.12148.10.15.21.4 | Integer32 (0..1440) | RW | ||||||||||||||||||
scalar · Integer32 (0..1440) · read-write · current A protection against overcharging. When running manual equalize, the boosting will always terminate at this point. | |||||||||||||||||||||
| NbatteryGroup2AhCharged | 1.3.6.1.4.1.12148.10.15.22 | ||||||||||||||||||||
| SbatteryGroup2AhChargedStatus | 1.3.6.1.4.1.12148.10.15.22.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery ah charged monitor.
| |||||||||||||||||||||
| SbatteryGroup2AhChargedDescription | 1.3.6.1.4.1.12148.10.15.22.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery ah charged monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SbatteryGroup2AhChargedTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.22.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryGroup2AhChargedAlarmEnable | 1.3.6.1.4.1.12148.10.15.22.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2AhChargedValue | 1.3.6.1.4.1.12148.10.15.22.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The calculated battery ah (x100) charged value. | |||||||||||||||||||||
| SbatteryGroup2AhChargedMinorHighLevel | 1.3.6.1.4.1.12148.10.15.22.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| SbatteryGroup2AhChargedMajorHighLevel | 1.3.6.1.4.1.12148.10.15.22.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| NbatteryGroup2AhDischarged | 1.3.6.1.4.1.12148.10.15.23 | ||||||||||||||||||||
| SbatteryGroup2AhDischargedStatus | 1.3.6.1.4.1.12148.10.15.23.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the battery ah discharged monitor.
| |||||||||||||||||||||
| SbatteryGroup2AhDischargedDescription | 1.3.6.1.4.1.12148.10.15.23.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the battery ah discharged monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SbatteryGroup2AhDischargedTrapRepeatCounter | 1.3.6.1.4.1.12148.10.15.23.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SbatteryGroup2AhDischargedAlarmEnable | 1.3.6.1.4.1.12148.10.15.23.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SbatteryGroup2AhDischargedValue | 1.3.6.1.4.1.12148.10.15.23.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The calculated battery ah (x100) discharged value. | |||||||||||||||||||||
| SbatteryGroup2AhDischargedMinorHighLevel | 1.3.6.1.4.1.12148.10.15.23.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor high alarm limit | |||||||||||||||||||||
| SbatteryGroup2AhDischargedMajorHighLevel | 1.3.6.1.4.1.12148.10.15.23.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major high alarm limit | |||||||||||||||||||||
| Ninverters | 1.3.6.1.4.1.12148.10.16 | ||||||||||||||||||||
| SinvertersStatus | 1.3.6.1.4.1.12148.10.16.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The overall status of inverter subsystem.
| |||||||||||||||||||||
| NinvertersCurrent | 1.3.6.1.4.1.12148.10.16.2 | ||||||||||||||||||||
| SinvertersCurrentStatus | 1.3.6.1.4.1.12148.10.16.2.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured total inverter current.
| |||||||||||||||||||||
| SinvertersCurrentDescription | 1.3.6.1.4.1.12148.10.16.2.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the total inverter current monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SinvertersCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.16.2.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SinvertersCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.16.2.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SinvertersCurrentValue | 1.3.6.1.4.1.12148.10.16.2.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The value of the measured total inverter current. | |||||||||||||||||||||
| SinvertersCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.16.2.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SinvertersCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.16.2.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NinvertersCapacity | 1.3.6.1.4.1.12148.10.16.3 | ||||||||||||||||||||
| SinvertersCapacityStatus | 1.3.6.1.4.1.12148.10.16.3.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the measured used inverter capacity.
| |||||||||||||||||||||
| SinvertersCapacityDescription | 1.3.6.1.4.1.12148.10.16.3.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the used inverter capacity monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SinvertersCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.16.3.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SinvertersCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.16.3.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SinvertersCapacityValue | 1.3.6.1.4.1.12148.10.16.3.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The used inverter capacity value presented in percentage of the total installed inverter capacity. | |||||||||||||||||||||
| SinvertersCapacityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.16.3.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SinvertersCapacityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.16.3.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| NinvertersError | 1.3.6.1.4.1.12148.10.16.4 | ||||||||||||||||||||
| SinvertersErrorStatus | 1.3.6.1.4.1.12148.10.16.4.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This status value shows if the number of failed units is higher than the defined alarm level.
| |||||||||||||||||||||
| SinvertersErrorDescription | 1.3.6.1.4.1.12148.10.16.4.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..16)) · read-write · current A textual description of the inverter error monitor. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| SinvertersErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.16.4.3 | Counter32 | AN | ||||||||||||||||||
scalar · Counter32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| SinvertersErrorEnable | 1.3.6.1.4.1.12148.10.16.4.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| SinvertersErrorValue | 1.3.6.1.4.1.12148.10.16.4.5 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The number of failed inverters. | |||||||||||||||||||||
| SinvertersErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.16.4.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| SinvertersErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.16.4.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| SinvertersNumberOfInverters | 1.3.6.1.4.1.12148.10.16.5 | Integer32 (0..100) | RW | ||||||||||||||||||
scalar · Integer32 (0..100) · read-write · current Number of installed inverters. | |||||||||||||||||||||
| TinverterTable | 1.3.6.1.4.1.12148.10.16.6 | NA | |||||||||||||||||||
table · not-accessible · current This table shows the information of each inverter installed in the system. | |||||||||||||||||||||
| RinverterEntry | 1.3.6.1.4.1.12148.10.16.6.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinverterIndex | 1.3.6.1.4.1.12148.10.16.6.1.1 | Integer32 (1..100) | NA | ||||||||||||||||||
column · Integer32 (1..100) · not-accessible · current Index used for navigating the rows 1..100 of inverterTable | |||||||||||||||||||||
| CinverterStatus | 1.3.6.1.4.1.12148.10.16.6.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of inverter.
| |||||||||||||||||||||
| CinverterOutputCurrentValue | 1.3.6.1.4.1.12148.10.16.6.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output current value of inverter. | |||||||||||||||||||||
| CinverterOutputVoltageValue | 1.3.6.1.4.1.12148.10.16.6.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output voltage value of inverter. | |||||||||||||||||||||
| CinverterType | 1.3.6.1.4.1.12148.10.16.6.1.5 | DisplayString (SIZE (0..27)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..27)) · read-only · current Type of inverter | |||||||||||||||||||||
| CinverterHwPartNumber | 1.3.6.1.4.1.12148.10.16.6.1.6 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of inverter | |||||||||||||||||||||
| CinverterHwVersion | 1.3.6.1.4.1.12148.10.16.6.1.7 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Hardware version number of inverter | |||||||||||||||||||||
| CinverterSwPartNumber | 1.3.6.1.4.1.12148.10.16.6.1.8 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Part number of secondary software in inverter | |||||||||||||||||||||
| CinverterSwVersion | 1.3.6.1.4.1.12148.10.16.6.1.9 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Version number of secondary software in inverter | |||||||||||||||||||||
| CinverterOutputFrequencyValue | 1.3.6.1.4.1.12148.10.16.6.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output frequency value of inverter. | |||||||||||||||||||||
| CinverterOutputPowerValue | 1.3.6.1.4.1.12148.10.16.6.1.11 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output power value of inverter. | |||||||||||||||||||||
| CinverterOutputReactivePowerValue | 1.3.6.1.4.1.12148.10.16.6.1.12 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output reactive power value of inverter. | |||||||||||||||||||||
| SinvertersNumberOfGroups | 1.3.6.1.4.1.12148.10.16.7 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Number of inverter groups | |||||||||||||||||||||
| TinverterGroupsTable | 1.3.6.1.4.1.12148.10.16.8 | NA | |||||||||||||||||||
table · not-accessible · current This table contains status and the number of installed inverters of each inverter groups. | |||||||||||||||||||||
| RinverterGroupsEntry | 1.3.6.1.4.1.12148.10.16.8.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinverterGroupIndex | 1.3.6.1.4.1.12148.10.16.8.1.1 | Integer32 (1..10) | NA | ||||||||||||||||||
column · Integer32 (1..10) · not-accessible · current Index used for navigating the rows 1..10 of inverterGroupsTable | |||||||||||||||||||||
| CinverterGroupStatus | 1.3.6.1.4.1.12148.10.16.8.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of each inverter group.
| |||||||||||||||||||||
| CinverterGroupNumberOfInverters | 1.3.6.1.4.1.12148.10.16.8.1.3 | Integer32 (0..100) | RW | ||||||||||||||||||
column · Integer32 (0..100) · read-write · current Number of installed inverters in each inverter groups | |||||||||||||||||||||
| TinverterGroupCurrentTable | 1.3.6.1.4.1.12148.10.16.9 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the total inverter current of each inverter groups, which is calculated by summing up current from each inverter in a inverter group. | |||||||||||||||||||||
| RinverterGroupCurrentEntry | 1.3.6.1.4.1.12148.10.16.9.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinverterGroupCurrentStatus | 1.3.6.1.4.1.12148.10.16.9.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured total inverter current of the inverter group
| |||||||||||||||||||||
| CinverterGroupCurrentDescription | 1.3.6.1.4.1.12148.10.16.9.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the total inverter current monitor of a inverter group. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CinverterGroupCurrentTrapRepeatCounter | 1.3.6.1.4.1.12148.10.16.9.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CinverterGroupCurrentAlarmEnable | 1.3.6.1.4.1.12148.10.16.9.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CinverterGroupCurrentValue | 1.3.6.1.4.1.12148.10.16.9.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The value of the measured total inverter current of each inverter group. | |||||||||||||||||||||
| CinverterGroupCurrentMajorAlarmLevel | 1.3.6.1.4.1.12148.10.16.9.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CinverterGroupCurrentMinorAlarmLevel | 1.3.6.1.4.1.12148.10.16.9.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TinverterGroupCapacityTable | 1.3.6.1.4.1.12148.10.16.10 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the used inverter capacity of each inverter group. | |||||||||||||||||||||
| RinverterGroupCapacityEntry | 1.3.6.1.4.1.12148.10.16.10.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinverterGroupCapacityStatus | 1.3.6.1.4.1.12148.10.16.10.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The status of the measured used inverter capacity of each inverter group
| |||||||||||||||||||||
| CinverterGroupCapacityDescription | 1.3.6.1.4.1.12148.10.16.10.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the used inverter capacity monitor of each inverter group. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CinverterGroupCapacityTrapRepeatCounter | 1.3.6.1.4.1.12148.10.16.10.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CinverterGroupCapacityAlarmEnable | 1.3.6.1.4.1.12148.10.16.10.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CinverterGroupCapacityValue | 1.3.6.1.4.1.12148.10.16.10.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The used inverter capacity value presented in percentage of the total installed inverter capacity of each inverter group. | |||||||||||||||||||||
| CinverterGroupCapacityMajorAlarmLevel | 1.3.6.1.4.1.12148.10.16.10.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CinverterGroupCapacityMinorAlarmLevel | 1.3.6.1.4.1.12148.10.16.10.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TinverterGroupErrorTable | 1.3.6.1.4.1.12148.10.16.11 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the inverter error monitor of each inverter group. | |||||||||||||||||||||
| RinverterGroupErrorEntry | 1.3.6.1.4.1.12148.10.16.11.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinverterGroupErrorStatus | 1.3.6.1.4.1.12148.10.16.11.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This status value shows if the number of failed units is higher than the defined alarm level.
| |||||||||||||||||||||
| CinverterGroupErrorDescription | 1.3.6.1.4.1.12148.10.16.11.1.2 | DisplayString (SIZE (0..16)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-write · current A textual description of the inverter error monitor of each inverter group. This is stored in the system controller and can be changed by the user | |||||||||||||||||||||
| CinverterGroupErrorTrapRepeatCounter | 1.3.6.1.4.1.12148.10.16.11.1.3 | Integer32 | AN | ||||||||||||||||||
column · Integer32 · accessible-for-notify · current The number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off | |||||||||||||||||||||
| CinverterGroupErrorAlarmEnable | 1.3.6.1.4.1.12148.10.16.11.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This value once enabled, the alarm condition of the monitor will be reported.
| |||||||||||||||||||||
| CinverterGroupErrorValue | 1.3.6.1.4.1.12148.10.16.11.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of failed inverters of each inverter group. | |||||||||||||||||||||
| CinverterGroupErrorMajorAlarmLevel | 1.3.6.1.4.1.12148.10.16.11.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The major alarm limit | |||||||||||||||||||||
| CinverterGroupErrorMinorAlarmLevel | 1.3.6.1.4.1.12148.10.16.11.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current The minor alarm limit | |||||||||||||||||||||
| TinverterGroupInverterTable | 1.3.6.1.4.1.12148.10.16.12 | NA | |||||||||||||||||||
table · not-accessible · current This table shows the information of each inverter installed in each of the inverter group in the system. | |||||||||||||||||||||
| RinverterGroupInverterEntry | 1.3.6.1.4.1.12148.10.16.12.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinverterGroupInverterIndex | 1.3.6.1.4.1.12148.10.16.12.1.1 | Integer32 (1..100) | NA | ||||||||||||||||||
column · Integer32 (1..100) · not-accessible · current Index used for navigating the rows 1..100 of inverterGroupinverterTable | |||||||||||||||||||||
| CinverterGroupInverterStatus | 1.3.6.1.4.1.12148.10.16.12.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The overall status of inverter.
| |||||||||||||||||||||
| CinverterGroupInverterOutputCurrentValue | 1.3.6.1.4.1.12148.10.16.12.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output current value of inverter. | |||||||||||||||||||||
| CinverterGroupInverterOutputVoltageValue | 1.3.6.1.4.1.12148.10.16.12.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output voltage value of inverter. | |||||||||||||||||||||
| CinverterGroupInverterType | 1.3.6.1.4.1.12148.10.16.12.1.5 | DisplayString (SIZE (0..27)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..27)) · read-only · current Type of inverter | |||||||||||||||||||||
| CinverterGroupInverterHwPartNumber | 1.3.6.1.4.1.12148.10.16.12.1.6 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Hardware part number of inverter | |||||||||||||||||||||
| CinverterGroupInverterHwVersion | 1.3.6.1.4.1.12148.10.16.12.1.7 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Hardware version number of inverter | |||||||||||||||||||||
| CinverterGroupInverterSwPartNumber | 1.3.6.1.4.1.12148.10.16.12.1.8 | DisplayString (SIZE (0..12)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-only · current Part number of secondary software in inverter | |||||||||||||||||||||
| CinverterGroupInverterSwVersion | 1.3.6.1.4.1.12148.10.16.12.1.9 | DisplayString (SIZE (0..6)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..6)) · read-only · current Version number of secondary software in inverter | |||||||||||||||||||||
| CinverterGroupInverterOutputFrequencyValue | 1.3.6.1.4.1.12148.10.16.12.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output frequency value of inverter. | |||||||||||||||||||||
| CinverterGroupInverterOutputPowerValue | 1.3.6.1.4.1.12148.10.16.12.1.11 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output power value of inverter. | |||||||||||||||||||||
| CinverterGroupInverterOutputReactivePowerValue | 1.3.6.1.4.1.12148.10.16.12.1.12 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The output reactive power value of inverter. | |||||||||||||||||||||
| NinvertersEnergyLog | 1.3.6.1.4.1.12148.10.16.13 | ||||||||||||||||||||
| SinvertersEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.16.13.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated energy delivered from inverters. | |||||||||||||||||||||
| SinvertersEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.16.13.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in inverter hourly energy log. | |||||||||||||||||||||
| TinvertersEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.16.13.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of inverters. | |||||||||||||||||||||
| RinvertersEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.16.13.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinvertersEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.16.13.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of invertersEnergyLogLastHoursTable | |||||||||||||||||||||
| CinvertersEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.16.13.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. | |||||||||||||||||||||
| SinvertersEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.16.13.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in inverter daily energy log. | |||||||||||||||||||||
| TinvertersEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.16.13.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of inverters. | |||||||||||||||||||||
| RinvertersEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.16.13.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinvertersEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.16.13.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of invertersEnergyLogLastDaysTable | |||||||||||||||||||||
| CinvertersEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.16.13.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. | |||||||||||||||||||||
| SinvertersEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.16.13.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in inverter weekly energy log. | |||||||||||||||||||||
| TinvertersEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.16.13.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of inverters. | |||||||||||||||||||||
| RinvertersEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.16.13.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinvertersEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.16.13.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of invertersEnergyLogLastWeekTable | |||||||||||||||||||||
| CinvertersEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.16.13.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every week. | |||||||||||||||||||||
| TinverterGroupEnergyLogTable | 1.3.6.1.4.1.12148.10.16.14 | NA | |||||||||||||||||||
table · not-accessible · current This branch contains information about inverters' energy logs of each inverter group. | |||||||||||||||||||||
| RinverterGroupEnergyLogEntry | 1.3.6.1.4.1.12148.10.16.14.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinverterGroupEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.16.14.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the accumulated energy delivered from inverters of each inverter group. | |||||||||||||||||||||
| CinverterGroupEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.16.14.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in inverter group hourly energy log. | |||||||||||||||||||||
| CinverterGroupEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.16.14.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in inverter group daily energy log. | |||||||||||||||||||||
| CinverterGroupEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.16.14.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in inverter group weekly energy log. | |||||||||||||||||||||
| TinverterGroupEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.16.15 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly energy log of each inverter group | |||||||||||||||||||||
| RinverterGroupEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.16.15.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinverterGroupEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.16.15.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of inverterGroupEnergyLogLastHoursTable | |||||||||||||||||||||
| CinverterGroupEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.16.15.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every hour. | |||||||||||||||||||||
| TinverterGroupEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.16.16 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily energy log of each inverter group | |||||||||||||||||||||
| RinverterGroupEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.16.16.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinverterGroupEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.16.16.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of inverterGroupEnergyLogLasDaysTable | |||||||||||||||||||||
| CinverterGroupEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.16.16.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every day. | |||||||||||||||||||||
| TinverterGroupEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.16.17 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly energy log of each inverter group | |||||||||||||||||||||
| RinverterGroupEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.16.17.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinverterGroupEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.16.17.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of inverterGroupEnergyLogLastWeeksTable | |||||||||||||||||||||
| CinverterGroupEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.16.17.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Energy value logged every week. | |||||||||||||||||||||
| NinvertersReactiveEnergyLog | 1.3.6.1.4.1.12148.10.16.18 | ||||||||||||||||||||
| SinvertersReactiveEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.16.18.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current This is the accumulated reactive energy delivered from inverters. | |||||||||||||||||||||
| SinvertersReactiveEnergyLogLastHoursNumberOfEntries | 1.3.6.1.4.1.12148.10.16.18.2 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in inverter hourly reactive energy log. | |||||||||||||||||||||
| TinvertersReactiveEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.16.18.3 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly reactive energy log of inverters. | |||||||||||||||||||||
| RinvertersReactiveEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.16.18.3.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinvertersReactiveEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.16.18.3.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of invertersReactiveEnergyLogLastHoursTable | |||||||||||||||||||||
| CinvertersReactiveEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.16.18.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Reactive energy value logged every hour. | |||||||||||||||||||||
| SinvertersReactiveEnergyLogLastDaysNumberOfEntries | 1.3.6.1.4.1.12148.10.16.18.4 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in inverter daily reactive energy log. | |||||||||||||||||||||
| TinvertersReactiveEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.16.18.5 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily reactive energy log of inverters. | |||||||||||||||||||||
| RinvertersReactiveEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.16.18.5.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinvertersReactiveEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.16.18.5.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of invertersReactiveEnergyLogLastDaysTable | |||||||||||||||||||||
| CinvertersReactiveEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.16.18.5.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Reactive energy value logged every day. | |||||||||||||||||||||
| SinvertersReactiveEnergyLogLastWeeksNumberOfEntries | 1.3.6.1.4.1.12148.10.16.18.6 | Integer32 (0..52) | RO | ||||||||||||||||||
scalar · Integer32 (0..52) · read-only · current This is the maximal number of entries stored in inverter weekly reactive energy log. | |||||||||||||||||||||
| TinvertersReactiveEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.16.18.7 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly reactive energy log of inverters. | |||||||||||||||||||||
| RinvertersReactiveEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.16.18.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinvertersReactiveEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.16.18.7.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of invertersReactiveEnergyLogLastWeekTable | |||||||||||||||||||||
| CinvertersReactiveEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.16.18.7.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Reactive energy value logged every week. | |||||||||||||||||||||
| TinverterGroupReactiveEnergyLogTable | 1.3.6.1.4.1.12148.10.16.19 | NA | |||||||||||||||||||
table · not-accessible · current This branch contains information about inverters' reactive energy logs of each inverter group. | |||||||||||||||||||||
| RinverterGroupReactiveEnergyLogEntry | 1.3.6.1.4.1.12148.10.16.19.1 | NA | |||||||||||||||||||
row · not-accessible · current
| |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogAccumulated | 1.3.6.1.4.1.12148.10.16.19.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the accumulated reactive energy delivered from inverters of each inverter group. | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastHoursNoOfEntries | 1.3.6.1.4.1.12148.10.16.19.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in inverter group hourly reactive energy log. | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastDaysNoOfEntries | 1.3.6.1.4.1.12148.10.16.19.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in inverter group daily reactive energy log. | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastWeeksNoOfEntries | 1.3.6.1.4.1.12148.10.16.19.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current This is the maximal number of entries stored in inverter group weekly reactive energy log. | |||||||||||||||||||||
| TinverterGroupReactiveEnergyLogLastHoursTable | 1.3.6.1.4.1.12148.10.16.20 | NA | |||||||||||||||||||
table · not-accessible · current This table contains hourly reactive energy log of each inverter group | |||||||||||||||||||||
| RinverterGroupReactiveEnergyLogLastHoursEntry | 1.3.6.1.4.1.12148.10.16.20.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastHoursIndex | 1.3.6.1.4.1.12148.10.16.20.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of inverterGroupReactiveEnergyLogLastHoursTable | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastHoursValue | 1.3.6.1.4.1.12148.10.16.20.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Reactive energy value logged every hour. | |||||||||||||||||||||
| TinverterGroupReactiveEnergyLogLastDaysTable | 1.3.6.1.4.1.12148.10.16.21 | NA | |||||||||||||||||||
table · not-accessible · current This table contains daily reactive energy log of each inverter group | |||||||||||||||||||||
| RinverterGroupReactiveEnergyLogLastDaysEntry | 1.3.6.1.4.1.12148.10.16.21.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastDaysIndex | 1.3.6.1.4.1.12148.10.16.21.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of inverterGroupReactiveEnergyLogLasDaysTable | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastDaysValue | 1.3.6.1.4.1.12148.10.16.21.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Reactive energy value logged every day. | |||||||||||||||||||||
| TinverterGroupReactiveEnergyLogLastWeeksTable | 1.3.6.1.4.1.12148.10.16.22 | NA | |||||||||||||||||||
table · not-accessible · current This table contains weekly reactive energy log of each inverter group | |||||||||||||||||||||
| RinverterGroupReactiveEnergyLogLastWeeksEntry | 1.3.6.1.4.1.12148.10.16.22.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastWeeksIndex | 1.3.6.1.4.1.12148.10.16.22.1.1 | Integer32 (1..52) | NA | ||||||||||||||||||
column · Integer32 (1..52) · not-accessible · current Index used for navigating the rows 1..52 of inverterGroupReactiveEnergyLogLastWeeksTable | |||||||||||||||||||||
| CinverterGroupReactiveEnergyLogLastWeeksValue | 1.3.6.1.4.1.12148.10.16.22.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Reactive energy value logged every week. | |||||||||||||||||||||
Traps / Notifications
- alarmBatteryTrap
1.3.6.1.4.1.12148.10.1.2.2 - alarmControlSystemTrap
1.3.6.1.4.1.12148.10.1.2.6 - alarmDcDcTrap
1.3.6.1.4.1.12148.10.1.2.7 - alarmGeneratorTrap
1.3.6.1.4.1.12148.10.1.2.10 - alarmInputsTrap
1.3.6.1.4.1.12148.10.1.2.8 - alarmInverterTrap
1.3.6.1.4.1.12148.10.1.2.14 - alarmLoadGroupTrap
1.3.6.1.4.1.12148.10.1.2.3 - alarmMainsTrap
1.3.6.1.4.1.12148.10.1.2.4 - alarmOutputsTrap
1.3.6.1.4.1.12148.10.1.2.9 - alarmPowerSystemTrap
1.3.6.1.4.1.12148.10.1.2.1 - alarmRectifierTrap
1.3.6.1.4.1.12148.10.1.2.5 - alarmSolarChargerTrap
1.3.6.1.4.1.12148.10.1.2.11 - alarmWindChargerTrap
1.3.6.1.4.1.12148.10.1.2.12 - infoHeartBeatTrap
1.3.6.1.4.1.12148.10.1.2.13