EKINOPS-MGNT2-MIB
Ekinops SASMIB for Ekinops 360 management.
snmptranslate -m EKINOPS-MGNT2-MIB -Tpsnmpwalk -v2c -c <community> -m EKINOPS-MGNT2-MIB <host> 1.3.6.1.4.1.20044.7Imports
| EKINOPS-MIB | EkiApiState, EkiLoadGWSW, EkiLoadPermutMethod, EkiLoadPermutMode, EkiLoadState, EkiOnOff, EkiProtocol, EkiState, EkiSynchroMode, ekinops |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Imgnt2 | 1.3.6.1.4.1.20044.7 | ||||||||||||
identity MIB for Ekinops 360 management. | |||||||||||||
| Nmgnt2SNMPAgentData | 1.3.6.1.4.1.20044.7.1 | ||||||||||||
| Nmgnt2IPmanagment | 1.3.6.1.4.1.20044.7.1.1 | ||||||||||||
| Tmgnt2GigmManagerIpAddressTable | 1.3.6.1.4.1.20044.7.1.1.1 | NA | |||||||||||
table · not-accessible · current Manager IP address Table. | |||||||||||||
| Rmgnt2GigmManagerIpAddressEntry | 1.3.6.1.4.1.20044.7.1.1.1.1 | NA | |||||||||||
row · not-accessible · current | |||||||||||||
| Cmgnt2GigmManagerIpIndex | 1.3.6.1.4.1.20044.7.1.1.1.1.1 | Integer32 (1..32) | RC | ||||||||||
column · Integer32 (1..32) · read-create · current Index of the IP address of the manager | |||||||||||||
| Cmgnt2GigmManagerIpAddress | 1.3.6.1.4.1.20044.7.1.1.1.1.2 | IpAddress | RC | ||||||||||
column · IpAddress · read-create · current IP address of the manager:This OID defines the IP address of the SNMP Manager attached to the Mgnt2 | |||||||||||||
| Cmgnt2GigmManagerIpAddressTableRowStatus | 1.3.6.1.4.1.20044.7.1.1.1.1.3 | RowStatus | RC | ||||||||||
column · RowStatus · read-create · current The status of this row. | |||||||||||||
| Cmgnt2GigmManagerTrapPort | 1.3.6.1.4.1.20044.7.1.1.1.1.4 | Integer32 | RC | ||||||||||
column · Integer32 · read-create · current Manager UDP port. | |||||||||||||
| Cmgnt2GigmManagerEnableCtrl | 1.3.6.1.4.1.20044.7.1.1.1.1.5 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of Ctrl. | |||||||||||||
| Cmgnt2GigmManagerEnableConfig | 1.3.6.1.4.1.20044.7.1.1.1.1.6 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of config. | |||||||||||||
| Cmgnt2GigmManagerEnableEvent | 1.3.6.1.4.1.20044.7.1.1.1.1.7 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of event. | |||||||||||||
| Cmgnt2GigmManagerEnableAlarmCrit | 1.3.6.1.4.1.20044.7.1.1.1.1.8 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of crit alarm. | |||||||||||||
| Cmgnt2GigmManagerEnableAlarmMajor | 1.3.6.1.4.1.20044.7.1.1.1.1.9 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of major alarm. | |||||||||||||
| Cmgnt2GigmManagerEnableAlarmMinor | 1.3.6.1.4.1.20044.7.1.1.1.1.10 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of minor alarm. | |||||||||||||
| Cmgnt2GigmManagerRegistrationTimeout | 1.3.6.1.4.1.20044.7.1.1.1.1.11 | Integer32 | RC | ||||||||||
column · Integer32 · read-create · current Time-out for manager activities. | |||||||||||||
| Cmgnt2GigmManagerEnableAlarmWarning | 1.3.6.1.4.1.20044.7.1.1.1.1.12 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of warning alarm. | |||||||||||||
| Cmgnt2GigmManagerEnableAlarmIndeterminate | 1.3.6.1.4.1.20044.7.1.1.1.1.13 | EkiOnOff | RC | ||||||||||
column · EkiOnOff · read-create · current Enabling trap of indeterminate alarm. | |||||||||||||
| Smgnt2GigmBoardIpAddress | 1.3.6.1.4.1.20044.7.1.1.2 | IpAddress | RW | ||||||||||
scalar · IpAddress · read-write · current IP address of the Chassis:This OID defines the IP address of the Mgnt2 | |||||||||||||
| Smgnt2GigmIPAddresByDHCP | 1.3.6.1.4.1.20044.7.1.1.3 | EkiState | RW | ||||||||||
scalar · EkiState · read-write · current IP address retrieved by DHCP:If enabled, the IP address is retrieved by DHCP, in which case changes take effect after a board reset. If disabled the object, mgnt2GigmBoardIpAddress defines the address | |||||||||||||
| Smgnt2GigmNetmask | 1.3.6.1.4.1.20044.7.1.1.4 | IpAddress | RW | ||||||||||
scalar · IpAddress · read-write · current Netmask for the board IP address:This OID defined the IP Subnet mask of the Mgnt2 | |||||||||||||
| Tmgnt2GigmGatewayAddressTable | 1.3.6.1.4.1.20044.7.1.1.5 | NA | |||||||||||
table · not-accessible · current Gateway IP address Table: This table contains all the gateway IP addresses. | |||||||||||||
| Rmgnt2GigmGatewayAddressEntry | 1.3.6.1.4.1.20044.7.1.1.5.1 | NA | |||||||||||
row · not-accessible · current | |||||||||||||
| Cmgnt2GigmGatewayIndex | 1.3.6.1.4.1.20044.7.1.1.5.1.1 | Integer32 (0..1) | RC | ||||||||||
column · Integer32 (0..1) · read-create · current Index of the IP address of the gateway | |||||||||||||
| Cmgnt2GigmGatewayAddress | 1.3.6.1.4.1.20044.7.1.1.5.1.2 | IpAddress | RC | ||||||||||
column · IpAddress · read-create · current IP address of the gateway :This OID defines the IP address of the gateway attached to the Chassis | |||||||||||||
| Cmgnt2GigmGatewayOrder | 1.3.6.1.4.1.20044.7.1.1.5.1.3 | Integer32 | RC | ||||||||||
column · Integer32 · read-create · current Gateway priority: This OID defines the priority of the gateway (lower number for higher priority) | |||||||||||||
| Smgnt2GigmSyslog | 1.3.6.1.4.1.20044.7.1.1.6 | IpAddress | RW | ||||||||||
scalar · IpAddress · read-write · current IP address of the syslog server:This OID defines the IP address of the syslog of the Mgnt2 | |||||||||||||
| Smgnt2GigmNtpServer | 1.3.6.1.4.1.20044.7.1.1.7 | IpAddress | RW | ||||||||||
scalar · IpAddress · read-write · current IP address of the ntp server:This OID defines the IP address of the ntp server for the Mgnt2 | |||||||||||||
| Smgnt2GigmNodeIpAddress | 1.3.6.1.4.1.20044.7.1.1.8 | IpAddress | RW | ||||||||||
scalar · IpAddress · read-write · current Node IP address :This OID defines the Node IP address in node controller mode for the Mgnt2 | |||||||||||||
| Nmgnt2ModulesManagement | 1.3.6.1.4.1.20044.7.1.2 | ||||||||||||
| Tmgnt2GigmBoardTable | 1.3.6.1.4.1.20044.7.1.2.1 | NA | |||||||||||
table · not-accessible · current List of PMs plugged in the Chassis | |||||||||||||
| Rmgnt2GigmBoardEntry | 1.3.6.1.4.1.20044.7.1.2.1.1 | NA | |||||||||||
| Cmgnt2IndexBoards | 1.3.6.1.4.1.20044.7.1.2.1.1.1 | Integer32 (1..32) | RO | 1 | |||||||||
| Cmgnt2Position | 1.3.6.1.4.1.20044.7.1.2.1.1.2 | Integer32 (1..32) | RO | 2 | |||||||||
| Cmgnt2Name | 1.3.6.1.4.1.20044.7.1.2.1.1.3 | DisplayString | RO | PM_OAIL-HCS | |||||||||
| Cmgnt2PortNumber | 1.3.6.1.4.1.20044.7.1.2.1.1.4 | Integer32 (1..32) | RO | 2 | |||||||||
| Cmgnt2LineNumber | 1.3.6.1.4.1.20044.7.1.2.1.1.5 | Integer32 (1..32) | RO | 2 | |||||||||
| Cmgnt2GroupNumber | 1.3.6.1.4.1.20044.7.1.2.1.1.6 | Integer32 (1..32) | RO | 0 | |||||||||
column · Integer32 (1..32) · read-only · current Number of Groups:This OID gives the number of group of clients on the PM plugged in the Mgnt2 Example values from LibreNMS test devices
| |||||||||||||
| Cmgnt2RootOIDInventory | 1.3.6.1.4.1.20044.7.1.2.1.1.7 | OBJECT IDENTIFIER | RO | 1.3.6.1.4.1.20044.62.7 | |||||||||
column · OBJECT IDENTIFIER · read-only · current root oid of the inventory leaf of the corresponding PM | |||||||||||||
| Cmgnt2SlotOcc | 1.3.6.1.4.1.20044.7.1.2.1.1.8 | DisplayString | RO | 2:1 | |||||||||
| Cmgnt2SubFunctionLabel | 1.3.6.1.4.1.20044.7.1.2.1.1.9 | DisplayString | RO | | |||||||||
| Cmgnt2SlotStatus | 1.3.6.1.4.1.20044.7.1.2.1.1.10 | Mgnt2SlotStatus | RO | 1 | |||||||||
column · Mgnt2SlotStatus · read-only · current Slot Status: This OID gives the status of the slot in the Chassis: See Textual COnvention Example values from LibreNMS test devices
| |||||||||||||
| Smgnt2GigmSelectedBoard | 1.3.6.1.4.1.20044.7.1.2.7 | INTEGER (1..256) | RW | ||||||||||
scalar · INTEGER (1..256) · read-write · current PM Slot number selected:PM selected for further operations in the Ekinops module board tree. This number is the slot number. | |||||||||||||
| Tmgnt2GigmMibsTable | 1.3.6.1.4.1.20044.7.1.4 | NA | obsolete | ||||||||||
table · not-accessible · obsolete List of MIBs supported by the Chassis SNMPAgent | |||||||||||||
| Rmgnt2GigmMibsEntry | 1.3.6.1.4.1.20044.7.1.4.1 | NA | obsolete | ||||||||||
| Cmgnt2IndexMibs | 1.3.6.1.4.1.20044.7.1.4.1.1 | Integer32 (1..100) | RO | obsolete | |||||||||
column · Integer32 (1..100) · read-only · obsolete Index for MIBs table | |||||||||||||
| Cmgnt2MibName | 1.3.6.1.4.1.20044.7.1.4.1.2 | DisplayString | RO | obsolete | |||||||||
column · DisplayString · read-only · obsolete MIB name:This OID gives the name of the MIBs supported by the SNMP Agent | |||||||||||||
| Cmgnt2MibPartNumber | 1.3.6.1.4.1.20044.7.1.4.1.3 | DisplayString | RO | obsolete | |||||||||
column · DisplayString · read-only · obsolete MIB Part Number:This OID gives the part number of the MIBs supported by the SNMP Agent | |||||||||||||
| Smgnt2GigmLogicalName | 1.3.6.1.4.1.20044.7.1.5 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Mgnt2 name:This OID defines the name of the Mgnt2 | |||||||||||||
| Smgnt2GigmEqptType | 1.3.6.1.4.1.20044.7.1.6 | Integer32 (1..128) | RO | ||||||||||
scalar · Integer32 (1..128) · read-only · current Equipment type:This OID defines the type of the Equipment | |||||||||||||
| Nmgnt2GigmTrapCount | 1.3.6.1.4.1.20044.7.1.7 | ||||||||||||
| Smgnt2GigmTrapCounter | 1.3.6.1.4.1.20044.7.1.7.1 | Integer32 (1..65535) | RO | ||||||||||
scalar · Integer32 (1..65535) · read-only · current Trap counter:This OID counts the number of trap sent | |||||||||||||
| Smgnt2GigmResetTrapCounter | 1.3.6.1.4.1.20044.7.1.7.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Reset trap counter:This OID reset the trap counter to 0 | |||||||||||||
| Nmgnt2GigmSecurity | 1.3.6.1.4.1.20044.7.1.8 | ||||||||||||
| Smgnt2GigmRoCommunity | 1.3.6.1.4.1.20044.7.1.8.1 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current SNMP Get community:This OID defines the community for the SNMP Get function | |||||||||||||
| Smgnt2GigmRwCommunity | 1.3.6.1.4.1.20044.7.1.8.2 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current SNMP Set community:This OID defines the community for the SNMP Set function | |||||||||||||
| Smgnt2GigmTrapCommunity | 1.3.6.1.4.1.20044.7.1.8.3 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current SNMP Trap community:This OID defines the community for the SNMP Trap function | |||||||||||||
| Nmgnt2GigmTime | 1.3.6.1.4.1.20044.7.1.9 | ||||||||||||
| Smgnt2GigmCurrentHour | 1.3.6.1.4.1.20044.7.1.9.1 | INTEGER (0..23) | RW | ||||||||||
scalar · INTEGER (0..23) · read-write · current Chassis Hour time:This OID defines the hour of the chassis' time | |||||||||||||
| Smgnt2GigmCurrentMinute | 1.3.6.1.4.1.20044.7.1.9.2 | INTEGER (0..59) | RW | ||||||||||
scalar · INTEGER (0..59) · read-write · current Chassis Minute time:This OID defines the minute of the chassis' time | |||||||||||||
| Smgnt2GigmCurrentYear | 1.3.6.1.4.1.20044.7.1.9.3 | INTEGER (1970..3000) | RW | ||||||||||
scalar · INTEGER (1970..3000) · read-write · current Chassis year date:This OID defines the year of the chassis' date | |||||||||||||
| Smgnt2GigmCurrentMonth | 1.3.6.1.4.1.20044.7.1.9.4 | INTEGER (1..12) | RW | ||||||||||
scalar · INTEGER (1..12) · read-write · current Chassis month date:This OID defines the month of the chassis' date | |||||||||||||
| Smgnt2GigmCurrentDay | 1.3.6.1.4.1.20044.7.1.9.5 | INTEGER (1..31) | RW | ||||||||||
scalar · INTEGER (1..31) · read-write · current Chassis day date:This OID defines the day of the chassis' date | |||||||||||||
| Nmgnt2Authentication | 1.3.6.1.4.1.20044.7.1.10 | ||||||||||||
| Smgnt2GigmRadiusServer | 1.3.6.1.4.1.20044.7.1.10.1 | IpAddress | RW | ||||||||||
scalar · IpAddress · read-write · current IP address of the RADIUS server:This OID defines the IP address of the external RADIUS server for authentication | |||||||||||||
| Smgnt2GigmRadiusPort | 1.3.6.1.4.1.20044.7.1.10.2 | Integer32 | RW | ||||||||||
scalar · Integer32 · read-write · current TCP port number of the RADIUS server:This OID defines
the TCP port number of the external RADIUS server for
authentication | |||||||||||||
| Smgnt2GigmRadiusSecret | 1.3.6.1.4.1.20044.7.1.10.3 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Shared secret of the RADIUS server:This OID defines
the shared secret password of the RADIUS server for
authentication | |||||||||||||
| Smgnt2GigmLdapHost | 1.3.6.1.4.1.20044.7.1.10.4 | IpAddress | RW | deprecated | |||||||||
scalar · IpAddress · read-write · deprecated IP address of the LDAP host:This OID defines the IP address of the external LDAP server for authentication | |||||||||||||
| Smgnt2GigmLdapPort | 1.3.6.1.4.1.20044.7.1.10.5 | Integer32 | RW | deprecated | |||||||||
scalar · Integer32 · read-write · deprecated TCP port number of the LDAP server:This OID defines
the TCP port number of the external LDAP server for
authentication | |||||||||||||
| Smgnt2GigmLdapBase | 1.3.6.1.4.1.20044.7.1.10.6 | DisplayString | RW | deprecated | |||||||||
scalar · DisplayString · read-write · deprecated LDAP base:This OID defines the name of the search
base of the LDAP server for
authentication<Help>LDAP base name spelled as follows:
'ou=users,ou=network,dc=yourcompany,dc=net' | |||||||||||||
| Smgnt2GigmLdapVersion | 1.3.6.1.4.1.20044.7.1.10.7 | Integer32 | RW | deprecated | |||||||||
scalar · Integer32 · read-write · deprecated Protocol number in use by the LDAP server:This OID defines
the protocol version used by the external LDAP server for
authentication<Help>Protocol version used by the external LDAP
server for authentication | |||||||||||||
| Smgnt2GigmLdapBindDn | 1.3.6.1.4.1.20044.7.1.10.8 | DisplayString | RW | deprecated | |||||||||
scalar · DisplayString · read-write · deprecated LDAP Bind DN:This OID defines the login name used to connect
into the LDAP server base for
authentication<Help>LDAP binddn spelled as follows:
'cn=ldap_admin,dc=yourcompany,dc=net' | |||||||||||||
| Smgnt2GigmLdapBindPw | 1.3.6.1.4.1.20044.7.1.10.9 | DisplayString | RW | deprecated | |||||||||
scalar · DisplayString · read-write · deprecated Credentials to bind the LDAP server with:This OID defines
the credentials to bind the LDAP server with for
authentication<Help>Credentials for LDAP access (bindpw) | |||||||||||||
| Smgnt2GigmLdapScope | 1.3.6.1.4.1.20044.7.1.10.10 | DisplayString | RW | deprecated | |||||||||
scalar · DisplayString · read-write · deprecated Scope for LDAP base search:This OID defines
the search scope for an LDAP base search
<Help>LDAP search scope | |||||||||||||
| Smgnt2GigmLdapPamPasswd | 1.3.6.1.4.1.20044.7.1.10.11 | DisplayString | RW | deprecated | |||||||||
scalar · DisplayString · read-write · deprecated PAM password handling:This OID defines
the way the PAM password is handled for LDAP authentication
<Help>The 'pam_password' option sould be one of the following:
'clear', 'crypt', 'md5', 'racf', 'exop' | |||||||||||||
| Smgnt2GigmAuthenticationType | 1.3.6.1.4.1.20044.7.1.10.12 | Mgnt2AuthTypeValues | RW | ||||||||||
scalar · Mgnt2AuthTypeValues · read-write · current Authentication type in use | |||||||||||||
| Nmgnt2Hardware | 1.3.6.1.4.1.20044.7.2 | ||||||||||||
| Nmgnt2alarms | 1.3.6.1.4.1.20044.7.2.1 | ||||||||||||
| Nmgnt2AlmsynthAlm0 | 1.3.6.1.4.1.20044.7.2.1.0 | ||||||||||||
| Smgnt2AlmAbsFailure | 1.3.6.1.4.1.20044.7.2.1.0.9 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Chassis Management Module Failure :This OID indicates that the Chassis Management module is in fail condition <Condtype> ABS_FAILURE <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFansFailure | 1.3.6.1.4.1.20044.7.2.1.0.10 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Chassis Fan Module Failure :This OID indicates that at least one of the three FAN unit of the FAN module is in fail condition <Condtype> FANS_FAILURE <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmDef48a | 1.3.6.1.4.1.20044.7.2.1.0.11 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Power Input A Present :This OID indicates that there is not input power on the right power connector (A) <Help> This alarm indicates if the power input B is present (left power connector) <Condtype> DEF_48A <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmDef48b | 1.3.6.1.4.1.20044.7.2.1.0.12 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Power Input B Present :This OID indicates that there is not input power on the right power connector (B) <Help> This alarm indicates if the power input B is present (right power connector) <Condtype> DEF_48B <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmMgntDefFuseA | 1.3.6.1.4.1.20044.7.2.1.0.15 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Mgnt Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Management board <Help> Status of the MGNT Fuse A <Condtype> MGNT_DEF_FUSE_A <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmMgntDefFuseB | 1.3.6.1.4.1.20044.7.2.1.0.16 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Mgnt Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Management board <Help> Status of the MGNT Fuse B <Condtype> MGNT_DEF_FUSE_B <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmsynthAlm1 | 1.3.6.1.4.1.20044.7.2.1.1 | ||||||||||||
| Smgnt2AlmNurgVisual | 1.3.6.1.4.1.20044.7.2.1.1.1 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Minor Chassis Alarm :This OID indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Condtype> NURG_VISUAL <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmUrgVisual | 1.3.6.1.4.1.20044.7.2.1.1.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Major Chassis Alarm :This OID indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Condtype> URG_VISUAL <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmCritVisual | 1.3.6.1.4.1.20044.7.2.1.1.3 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Critical Chassis Alarm :This OID indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Condtype> CRIT_VISUAL <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmAcknowledge | 1.3.6.1.4.1.20044.7.2.1.1.16 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Alarm Ack. :This OID indicates the alarms have been acknowledged by the user (locally or remotely) <Help> This status indicates the alarms have been acknowledged by the user (locally or remotely) <Condtype> ACKNOWLEDGE <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmboardMgmntSet1 | 1.3.6.1.4.1.20044.7.2.1.16 | ||||||||||||
| Smgnt2AlmPmSlot1Absent | 1.3.6.1.4.1.20044.7.2.1.16.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 1 :This OID indicates the presence of a PM in Slot 1 of the Chassis . <Help> This status indicates if a PM is detected in slot 1 <Condtype> PM_SLOT1_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot2Absent | 1.3.6.1.4.1.20044.7.2.1.16.3 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 2 :This OID indicates the presence of a PM in Slot 2 of the Chassis . <Help> This status indicates if a PM is detected in slot 2 <Condtype> PM_SLOT2_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot3Absent | 1.3.6.1.4.1.20044.7.2.1.16.4 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 3 :This OID indicates the presence of a PM in Slot 3 of the Chassis . <Help> This status indicates if a PM is detected in slot 3 <Condtype> PM_SLOT3_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot4Absent | 1.3.6.1.4.1.20044.7.2.1.16.5 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 4 :This OID indicates the presence of a PM in Slot 4 of the Chassis . <Help> This status indicates if a PM is detected in slot 4 <Condtype> PM_SLOT4_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot5Absent | 1.3.6.1.4.1.20044.7.2.1.16.6 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 5 :This OID indicates the presence of a PM in Slot 5 of the Chassis . <Help> This status indicates if a PM is detected in slot 5 <Condtype> PM_SLOT5_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot6Absent | 1.3.6.1.4.1.20044.7.2.1.16.7 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 6 :This OID indicates the presence of a PM in Slot 6 of the Chassis . <Help> This status indicates if a PM is detected in slot 6 <Condtype> PM_SLOT6_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot7Absent | 1.3.6.1.4.1.20044.7.2.1.16.8 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 7 :This OID indicates the presence of a PM in Slot 7 of the Chassis . <Help> This status indicates if a PM is detected in slot 7 <Condtype> PM_SLOT7_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot8Absent | 1.3.6.1.4.1.20044.7.2.1.16.9 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 8 :This OID indicates the presence of a PM in Slot 8 of the Chassis . <Help> This status indicates if a PM is detected in slot 8 <Condtype> PM_SLOT8_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot9Absent | 1.3.6.1.4.1.20044.7.2.1.16.10 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 9 :This OID indicates the presence of a PM in Slot 9 of the Chassis . <Help> This status indicates if a PM is detected in slot 9 <Condtype> PM_SLOT9_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot10Absent | 1.3.6.1.4.1.20044.7.2.1.16.11 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 10 :This OID indicates the presence of a PM in Slot 10 of the Chassis . <Help> This status indicates if a PM is detected in slot 10 <Condtype> PM_SLOT10_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot11Absent | 1.3.6.1.4.1.20044.7.2.1.16.12 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 11 :This OID indicates the presence of a PM in Slot 11 of the Chassis . <Help> This status indicates if a PM is detected in slot 11 <Condtype> PM_SLOT11_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmFanAbsent | 1.3.6.1.4.1.20044.7.2.1.16.14 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN module present in Chassis :This OID indicates the presence of the FAN module in the Chassis. <Help> This alarm indicates if the FAN module is detected in the chassis. <Condtype> PM_FAN_ABSENT <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmboardMgmntSet2 | 1.3.6.1.4.1.20044.7.2.1.17 | ||||||||||||
| Smgnt2AlmPmSlot12Absent | 1.3.6.1.4.1.20044.7.2.1.17.1 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 12 :This OID indicates the presence of a PM in Slot 12 of the Chassis . <Help> This status indicates if a PM is detected in slot 12 <Condtype> PM_SLOT12_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot13Absent | 1.3.6.1.4.1.20044.7.2.1.17.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 13 :This OID indicates the presence of a PM in Slot 13 of the Chassis . <Help> This status indicates if a PM is detected in slot 13 <Condtype> PM_SLOT13_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot14Absent | 1.3.6.1.4.1.20044.7.2.1.17.3 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 14 :This OID indicates the presence of a PM in Slot 14 of the Chassis . <Help> This status indicates if a PM is detected in slot 14 <Condtype> PM_SLOT14_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot15Absent | 1.3.6.1.4.1.20044.7.2.1.17.4 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 15 :This OID indicates the presence of a PM in Slot 15 of the Chassis . <Help> This status indicates if a PM is detected in slot 15 <Condtype> PM_SLOT15_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot16Absent | 1.3.6.1.4.1.20044.7.2.1.17.5 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 16 :This OID indicates the presence of a PM in Slot 16 of the Chassis . <Help> This status indicates if a PM is detected in slot 16 <Condtype> PM_SLOT16_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot17Absent | 1.3.6.1.4.1.20044.7.2.1.17.6 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 17 :This OID indicates the presence of a PM in Slot 17 of the Chassis . <Help> This status indicates if a PM is detected in slot 17 <Condtype> PM_SLOT17_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot18Absent | 1.3.6.1.4.1.20044.7.2.1.17.7 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 18 :This OID indicates the presence of a PM in Slot 18 of the Chassis . <Help> This status indicates if a PM is detected in slot 18 <Condtype> PM_SLOT18_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot19Absent | 1.3.6.1.4.1.20044.7.2.1.17.8 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 19 :This OID indicates the presence of a PM in Slot 19 of the Chassis . <Help> This status indicates if a PM is detected in slot 19 <Condtype> PM_SLOT19_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPmSlot20Absent | 1.3.6.1.4.1.20044.7.2.1.17.9 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current PM present in Chassis slot 20 :This OID indicates the presence of a PM in Slot 20 of the Chassis . <Help> This status indicates if a PM is detected in slot 20 <Condtype> PM_SLOT20_ABSENT <Probcause> other(1) <Alarmtype> other (1) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmfanMgmnt | 1.3.6.1.4.1.20044.7.2.1.20 | ||||||||||||
| Smgnt2AlmPbFan1Fail | 1.3.6.1.4.1.20044.7.2.1.20.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Unit #1 Failed On Fan Module :This OID indicates a failure on fan 1. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if the FAN #1 is in fail condition <Condtype> PB_FAN1_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPbFan2Fail | 1.3.6.1.4.1.20044.7.2.1.20.3 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Unit #2 Failed On Fan Module :This OID indicates a failure on fan 2. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if the FAN #2 is in fail condition <Condtype> PB_FAN2_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPbFan3Fail | 1.3.6.1.4.1.20044.7.2.1.20.4 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Unit #3 Failed On Fan Module :This OID indicates a failure on fan 3. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if the FAN #3 is in fail condition <Condtype> PB_FAN3_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPbFan4Fail | 1.3.6.1.4.1.20044.7.2.1.20.5 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Unit #4 Failed On Fan Module :This OID indicates a failure on fan 4. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if the FAN #4 is in fail condition <Condtype> PB_FAN4_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPbFan5Fail | 1.3.6.1.4.1.20044.7.2.1.20.6 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Unit #5 Failed On Fan Module :This OID indicates a failure on fan 5. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if the FAN #5 is in fail condition <Condtype> PB_FAN5_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPbFan6Fail | 1.3.6.1.4.1.20044.7.2.1.20.7 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Unit #6 Failed On Fan Module :This OID indicates a failure on fan 6. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if the FAN #6 is in fail condition <Condtype> PB_FAN6_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFanFilterAbsent | 1.3.6.1.4.1.20044.7.2.1.20.16 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Dust Filter Presence :This OID indicates that the dust filter is not present<Help> This alarm indicates if the Dust Filter is detected in the chassis. <Condtype> FAN_FILTER_ABSENT <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmfanPwrMgmnt | 1.3.6.1.4.1.20044.7.2.1.24 | ||||||||||||
| Smgnt2AlmFanPwrProtOn | 1.3.6.1.4.1.20044.7.2.1.24.12 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Backup Power :This OID indicates the backup power on the FAN module is switched on <Condtype> FAN_PWR_PROT_ON <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFanPwrFail1 | 1.3.6.1.4.1.20044.7.2.1.24.13 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Main Power :This OID indicates a failure on the main power of the FAN module <Help> This alarm indicates if one of the tow main power convert of the FAN module is in fail condition <Condtype> FAN_PWR_FAIL_1 <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFanDefFuseA | 1.3.6.1.4.1.20044.7.2.1.24.15 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Fan board <Help> Status of the FAN Fuse A <Condtype> FAN_DEF_FUSE_A <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFanDefFuseB | 1.3.6.1.4.1.20044.7.2.1.24.16 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Fan Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Fan board <Help> Status of the FAN Fuse B <Condtype> FAN_DEF_FUSE_B <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmremoveablefanModuleFail | 1.3.6.1.4.1.20044.7.2.1.25 | ||||||||||||
| Smgnt2AlmFan1ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.1 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #1 Present In Chassis :This OID indicates the presence of the FAN module #1 in the Chassis.<Help> This alarm indicates if the FAN module #1 is detected in the chassis. <Condtype> FAN1_MODULE_ABSENT <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFan2ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #2 Present In Chassis :This OID indicates the presence of the FAN module #2 in the Chassis.<Help> This alarm indicates if the FAN module #2 is detected in the chassis. <Condtype> FAN2_MODULE_ABSENT <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFan3ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.3 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #3 Present In Chassis :This OID indicates the presence of the FAN module #3 in the Chassis.<Help> This alarm indicates if the FAN module #3 is detected in the chassis. <Condtype> FAN3_MODULE_ABSENT <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFan4ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.4 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #4 Present In Chassis :This OID indicates the presence of the FAN module #4 in the Chassis.<Help> This alarm indicates if the FAN module #4 is detected in the chassis. <Condtype> FAN4_MODULE_ABSENT <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmremoveableFanModuleMgmnt | 1.3.6.1.4.1.20044.7.2.1.26 | ||||||||||||
| Smgnt2AlmFan1ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.1 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #1 Failure :This OID indicates a failure on FAN module #1 <Help> This alarm indicates if the FAN module #1 is in fail condition <Condtype> FAN1_MODULE_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFan2ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #2 Failure :This OID indicates a failure on FAN module #2 <Help> This alarm indicates if the FAN module #2 is in fail condition <Condtype> FAN2_MODULE_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFan3ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.3 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #3 Failure :This OID indicates a failure on FAN module #3 <Help> This alarm indicates if the FAN module #3 is in fail condition <Condtype> FAN3_MODULE_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFan4ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.4 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current FAN Module #4 Failure :This OID indicates a failure on FAN module #4 <Help> This alarm indicates if the FAN module #4 is in fail condition <Condtype> FAN4_MODULE_FAIL <Probcause> heatingVentCoolingSystemProblem (22) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmswAlarm1 | 1.3.6.1.4.1.20044.7.2.1.32 | ||||||||||||
| Smgnt2AlmApiError | 1.3.6.1.4.1.20044.7.2.1.32.1 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Comm fail between Agent and Transport :This OID indicates a failure detected on the Agent.The failure is located on a communication process with the modules. <Help> This alarm indicates if there is a communication mismatch between the MGNT board and a single PM <Condtype> API_ERROR <Probcause> adapterError (2) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmFifoCmdError | 1.3.6.1.4.1.20044.7.2.1.32.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current SNMP Agent to Transport comm FIFO fail :This OID indicates a failure inside the FIFO stack. The FIFO containing the messages from the agent (write) to the PMs is full <Help> This alarm indicates if there is a communication mismatch between the MGNT board and all PM <Condtype> FIFO_CMD_ERROR <Probcause> adapterError (2) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmPollingManagerError | 1.3.6.1.4.1.20044.7.2.1.32.3 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Polling Manager fail :This OID indicates a failure on the Manager polling the PM's <Help> <Help> This alarm indicates if there is a polling manager failure between the MGNT and the Pm's <Condtype> POLLING_MANAGER_ERROR <Probcause> adapterError (2) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmapiErrorCode | 1.3.6.1.4.1.20044.7.2.1.33 | INTEGER (0..255) | RO | ||||||||||
scalar · INTEGER (0..255) · read-only · current API Error Identification :Error number and description of the abs1AlmApiError object <Condtype> API_ERROR_CODE_1 <Probcause> <Alarmtype> | |||||||||||||
| Nmgnt2AlmlogMgmnt | 1.3.6.1.4.1.20044.7.2.1.34 | ||||||||||||
| Smgnt2AlmLogFileFull | 1.3.6.1.4.1.20044.7.2.1.34.1 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Log File Full Alarm :This OID indicates that a log file is full. This file must be cleared to insure correct log function <Help> This alarm indicates that one of the log file is Full <Condtype> LOG_FILE_FULL <Probcause> fileError (18) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Smgnt2AlmLog80Full | 1.3.6.1.4.1.20044.7.2.1.34.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current Log File Full Warning :This OID indicates that a log file is 80% full. <Help> This alarm indicates that one of the log file is 80% Full <Condtype> LOG_80_FULL <Probcause> fileError (18) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2AlmntpSyncLoss | 1.3.6.1.4.1.20044.7.2.1.35 | ||||||||||||
| Smgnt2AlmNtpSyncLoss | 1.3.6.1.4.1.20044.7.2.1.35.1 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current NTP Sync Loss :This OID indicates a loss of synchronisation with the NTP Server. <Help> This alarm indicates a loss of synchronisation with the NTP Server. <Condtype> NTP_SYNC_LOSS <Probcause> timingProblem (53) <Alarmtype> timeDomainViolation (11) <Polarity> (2) | |||||||||||||
| Smgnt2AlmCpuTempOverRange | 1.3.6.1.4.1.20044.7.2.1.35.2 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current CPU HighTemperature Warning :This OID indicates a temperature over the expected range on the CPU<Help> This warning indicates that the temperature of the CPU is reaching its internal limit <Condtype> CPU_TEMP_OVER_RANGE <Probcause> other(1) <Alarmtype> equipmentAlarm (5) <Polarity> (2) | |||||||||||||
| Nmgnt2controls | 1.3.6.1.4.1.20044.7.2.2 | ||||||||||||
| Nmgnt2Ctrlsynth5 | 1.3.6.1.4.1.20044.7.2.2.5 | ||||||||||||
| Smgnt2CtrlChassisShutdown | 1.3.6.1.4.1.20044.7.2.2.5.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Shut Down of the Management Module :This OID shall be set before shutting down the Chassis power. A delay of 5 sec is necessary between this OID is set and power is shut down. <Help> This control initiates a shutdown of the MGNT board, | |||||||||||||
| Smgnt2CtrlChassisWarmReset | 1.3.6.1.4.1.20044.7.2.2.5.3 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Reset of the Management Module :This oid triggers a 'warm' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration remains unchanged. <Help> This control initiates a warm reset of the MGNT board, | |||||||||||||
| Smgnt2CtrlChassisColdReset | 1.3.6.1.4.1.20044.7.2.2.5.4 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Cold Reset of the Management Module :This oid triggers a 'cold' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration remains unchanged. <Help> This control initiates a cold reset of the MGNT board, | |||||||||||||
| Nmgnt2CtrltestLed | 1.3.6.1.4.1.20044.7.2.2.18 | ||||||||||||
| Smgnt2CtrlGreenLed | 1.3.6.1.4.1.20044.7.2.2.18.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Green Leds Test :This OID switches on all the green Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the chassis to green | |||||||||||||
| Smgnt2CtrlRedLed | 1.3.6.1.4.1.20044.7.2.2.18.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Red Leds Test :This OID switches on all the red Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the chassis to red | |||||||||||||
| Smgnt2CtrlLedOff | 1.3.6.1.4.1.20044.7.2.2.18.3 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Switch off Leds Test :This OID switches off all the Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the complete chassis to OFF | |||||||||||||
| Nmgnt2CtrllogFile | 1.3.6.1.4.1.20044.7.2.2.19 | ||||||||||||
| Smgnt2CtrlLogFileReset | 1.3.6.1.4.1.20044.7.2.2.19.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Log File Reset :This OID clears all the log files | |||||||||||||
| Nmgnt2CtrlmgntSaveConfig | 1.3.6.1.4.1.20044.7.2.2.23 | ||||||||||||
| Smgnt2CtrlSaveConfig | 1.3.6.1.4.1.20044.7.2.2.23.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Save Configuration :This OID is used save the configuration related to the enable and mode traps objects <Help> This control saves the customer configuration on the MGNT board | |||||||||||||
| Nmgnt2CtrlmgntGetGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.24 | ||||||||||||
| Smgnt2CtrlGetGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.24.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Get Global Chassis Config :This OID is used to create a global configuration file of the chassis <Help> This control creates a single configuration file from PM's and MGNT configuration file into the RAM | |||||||||||||
| Nmgnt2CtrlmgntPutGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.25 | ||||||||||||
| Smgnt2CtrlPutGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.25.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Put Global Chassis Config :This OID is used to extract a global configuration file of the chassis <Help> This control creates configuration files to PM's and MGNT from a single configuration file in the RAM | |||||||||||||
| Nmgnt2CtrlmgntAcknowledge | 1.3.6.1.4.1.20044.7.2.2.26 | ||||||||||||
| Smgnt2CtrlAcknowledge | 1.3.6.1.4.1.20044.7.2.2.26.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Alarm Ack. :This OID is used to acknowledge the current active alarms of the chassis <Help> This control is used to acknowledge the current active alarms of the chassis | |||||||||||||
| Nmgnt2config | 1.3.6.1.4.1.20044.7.2.3 | ||||||||||||
| Nmgnt2CfgethPort2 | 1.3.6.1.4.1.20044.7.2.3.17 | ||||||||||||
| Smgnt2CfgEthPort2Disable | 1.3.6.1.4.1.20044.7.2.3.17.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current 2nd Ethernet Port Disable :This OID disables 'Ethernet Port 2' .When not required, this port must be disabled in order to prevent unwanted access. <Help> Disable the second Ethernet port | |||||||||||||
| Smgnt2CfgChassisEthernetSplit | 1.3.6.1.4.1.20044.7.2.3.17.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Chassis Ethernet Split :This OID enables the split between the two kendings. <Help> Enable/Disable the switch between the two kendings | |||||||||||||
| Smgnt2CfgmgntDccEnable | 1.3.6.1.4.1.20044.7.2.3.18 | Mgnt2DccAccessValues | RW | ||||||||||
scalar · Mgnt2DccAccessValues · read-write · current DCC Access :This OID selects the mode to enable the DCC on the slots. This Mode enables the Slots 2-4-6-8-10 , or the Slots 2-6-10-14-18. <Help> Defines the DCC access on the backplane of the chassis (Slots 2-4-6-8-10 or Slots 2-6-10-14-18) | |||||||||||||
| Nmgnt2CfgpmTrapEnable | 1.3.6.1.4.1.20044.7.2.3.20 | ||||||||||||
| Smgnt2CfgPmCriticalTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for all the PM plugged in the chassis <Help> In detailed traps mechanism, enable the trap emission on critical alarm detected on PM | |||||||||||||
| Smgnt2CfgPmMajorTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Major Alarm Traps Enable :This OID, when set, enables the generation of the major alarm trap for all the PM plugged in the chassis <Help> In detailed traps mechanism, enable the trap emission on major alarm detected on PM | |||||||||||||
| Smgnt2CfgPmMinorTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.3 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for all the PM plugged in the chassis <Help> In detailed traps mechanism, enable the trap emission on minor alarm detected on PM | |||||||||||||
| Smgnt2CfgPmControlTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.5 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Control Traps Enable :This OID,
when set, enables the generation
of a trap when a control is sent
to a PM plugged in the chassis
<Help> In detailed traps
mechanism, enable the trap emission
on control sent to PM | |||||||||||||
| Smgnt2CfgPmConfigTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.6 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a PM plugged in the chassis is modified <Help> In detailed traps mechanism, enable the trap emission on PM configuration modificatio | |||||||||||||
| Nmgnt2CfgmgntTrapEnable | 1.3.6.1.4.1.20044.7.2.3.21 | ||||||||||||
| Smgnt2CfgMgntCriticalTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current MGNT Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for the MGNT and FAN board <Help> In detailed traps mechanism, enable the trap emission on critical alarm detected on MGNT and FAN | |||||||||||||
| Smgnt2CfgMgntMajorTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current MGNT Major Traps Enable :This OID, when set, enables the generation of the major alarm trap for the MGNT and FAN board <Help> In detailed traps mechanism, enable the trap emission on major alarm detected on MGNT and FAN | |||||||||||||
| Smgnt2CfgMgntMinorTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.3 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current MGNT Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for the MGNT and FAN board <Help> In detailed traps mechanism, enable the trap emission on minor alarm detected on MGNT and FAN | |||||||||||||
| Smgnt2CfgMgntControlTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.5 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current MGNT Control Traps Enable :This
OID, when set, enables the generation
of a trap when a control is sent
to a MGNT plugged in the chassis
<Help> In detailed traps
mechanism, enable the trap emission
on control sent to MGNT | |||||||||||||
| Smgnt2CfgMgntConfigTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.6 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current MGNT Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a MGNT plugged in the chassis is modified <Help> In detailed traps mechanism, enable the trap emission on MGNT configuration modification | |||||||||||||
| Smgnt2CfgMgntEventTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.7 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current MGNT Event Traps Enable :This OID, when set, enables the generation of a trap when an event occurs on the chassis <Help> In detailed traps mechanism, enable the trap emission on event detected in the chassis | |||||||||||||
| Smgnt2CfgmgntTrapMode | 1.3.6.1.4.1.20044.7.2.3.22 | Mgnt2TrapModeValues | RW | ||||||||||
scalar · Mgnt2TrapModeValues · read-write · current Traps Mode :This OID is used to define the trap mode (synthetic or detailed mode) <Help> Selects the traps mechanism | |||||||||||||
| Nmgnt2CfgsyslogEnable | 1.3.6.1.4.1.20044.7.2.3.23 | ||||||||||||
| Smgnt2CfgSyslogEventEn | 1.3.6.1.4.1.20044.7.2.3.23.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Syslog Event Enable :This OID, when set, enables the generation of a syslog, when an event has been detected <Help> Enable a syslog emission on event detected on the chassis | |||||||||||||
| Smgnt2CfgSyslogConfigEn | 1.3.6.1.4.1.20044.7.2.3.23.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Syslog Config Enable :This OID, when set, enables the generation of a syslog, when the configuration has been changed. <Help> Enable a syslog emission on a configuration change detected on the chassis | |||||||||||||
| Smgnt2CfgSyslogCtrlEn | 1.3.6.1.4.1.20044.7.2.3.23.3 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Syslog Control Enable :This OID, when set, enables the generation of a syslog, when a control is set <Help> Enable a syslog emission on a control operated on the chassis | |||||||||||||
| Smgnt2CfgSyslogAlarmEn | 1.3.6.1.4.1.20044.7.2.3.23.4 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Syslog Alarm Enable :This OID, when set, enables the generation of a syslog, when an alarm occurs <Help> Enable a syslog emission on an alarm detected on the chassi | |||||||||||||
| Smgnt2CfgntpTimeZone | 1.3.6.1.4.1.20044.7.2.3.24 | INTEGER (-12..12) | RW | ||||||||||
scalar · INTEGER (-12..12) · read-write · current NTP Time Zone :This OID defines the time zone of the MGNT board for the NTP server <Help> This object defines the time zone of the MGNT board (from -12 to +12 hours from the GMT). | |||||||||||||
| Nmgnt2CfgpmConfEnable | 1.3.6.1.4.1.20044.7.2.3.25 | ||||||||||||
| Smgnt2CfgPmBackupEnable | 1.3.6.1.4.1.20044.7.2.3.25.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Automatic Config Backup :This OID enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modification. <Help> This parameter enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modificatio | |||||||||||||
| Smgnt2CfgPmRestoreEnable | 1.3.6.1.4.1.20044.7.2.3.25.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Automatic Config Restore :This OID enables the automatic PM configuration restore mechanism on PM insertion <Help> This parameter enables the automatic PM configuration restore mechanism on PM insertio | |||||||||||||
| Smgnt2CfginactivityTimeout | 1.3.6.1.4.1.20044.7.2.3.26 | INTEGER (-1..255) | RW | ||||||||||
scalar · INTEGER (-1..255) · read-write · current Idle Timeout :This OID defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI. <Help> This object defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI | |||||||||||||
| Smgnt2CfgcliAccess | 1.3.6.1.4.1.20044.7.2.3.27 | Mgnt2CliAccessValues | RW | ||||||||||
scalar · Mgnt2CliAccessValues · read-write · current CLI access :This OID selects the protocol for the remote access to a CLI user. <Help> This object defines the protocol used for a remote CLI. | |||||||||||||
| Smgnt2CfgcraftAccess | 1.3.6.1.4.1.20044.7.2.3.28 | Mgnt2CraftAccessValues | RW | ||||||||||
scalar · Mgnt2CraftAccessValues · read-write · current CRAFT access :This OID selects the remote access to a CRAFT user. <Help> This object defines the access for a remote CRAFT. | |||||||||||||
| Smgnt2CfgperfModes1 | 1.3.6.1.4.1.20044.7.2.3.29 | EkiSynchroMode | RW | ||||||||||
scalar · EkiSynchroMode · read-write · current PERF Synchro Source :This OID selects the source of the synchronisation (Internal/External). <Help> This object defines the source of the synchronization to operate performance monitoring. | |||||||||||||
| Smgnt2CfgalarmModelActiv | 1.3.6.1.4.1.20044.7.2.3.30 | Mgnt2AckMode | RW | ||||||||||
scalar · Mgnt2AckMode · read-write · current Acknowledge mode :This OID defines the alarms akcnowledge mode <Help> This configuration defines the alarms akcnowledge mode | |||||||||||||
| Smgnt2CfgnetworkInput | 1.3.6.1.4.1.20044.7.2.3.31 | Mgnt2NetMode | RW | ||||||||||
scalar · Mgnt2NetMode · read-write · current Network input :This OID selects the connection of the Ethernet Network input to either the switches (2) or the daughter board (1) , in this case the MGNT can act as a router <Help> This configuration defines the use of the Network input of the front panel | |||||||||||||
| Smgnt2CfgmasterEthMode | 1.3.6.1.4.1.20044.7.2.3.32 | Mgnt2MasterEthMode | RW | ||||||||||
scalar · Mgnt2MasterEthMode · read-write · current DHCP Master Ethernet Mode :This OID selects the mode of the Master Ethernet in DHCP mode (2) or in Static Mode(1) <Help> This configuration defines the use of the Master Ethernet Mode | |||||||||||||
| Smgnt2CfgsubnetMode | 1.3.6.1.4.1.20044.7.2.3.33 | Mgnt2SubnetEthMode | RW | ||||||||||
scalar · Mgnt2SubnetEthMode · read-write · current DHCP Subnet Mode :This OID selects the mode of the Subnet in DHCP mode (2) or in Static Mode(1) <Help> This configuration defines the use of the Subnet Mode | |||||||||||||
| Nmgnt2CfgrstpMode | 1.3.6.1.4.1.20044.7.2.3.34 | ||||||||||||
| Smgnt2CfgRstpEnable | 1.3.6.1.4.1.20044.7.2.3.34.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current RSTP Enable :This OID enables the RSTP algorythm <Help> This configuration defines the use of RSTP | |||||||||||||
| Nmgnt2CfglldpMode | 1.3.6.1.4.1.20044.7.2.3.35 | ||||||||||||
| Smgnt2CfgLldpEnable | 1.3.6.1.4.1.20044.7.2.3.35.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current LLDP Enable :This OID enables the LLDP algorythm <Help> This configuration defines the use of LLDP | |||||||||||||
| Smgnt2CfglogMode | 1.3.6.1.4.1.20044.7.2.3.36 | Mgnt2LogFileMode | RW | ||||||||||
scalar · Mgnt2LogFileMode · read-write · current Log Mode :This OID enables the log file mode<Help> This configuration defines the use of the log mod | |||||||||||||
| Nmgnt2CfgnodeMode | 1.3.6.1.4.1.20044.7.2.3.37 | ||||||||||||
| Smgnt2CfgNodeControllerEnable | 1.3.6.1.4.1.20044.7.2.3.37.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Node Controller Mode :This OID enables the node controller mode<Help> This configuration defines the use of the node controller mod | |||||||||||||
| Nmgnt2CfgunprivilegedUsersMode | 1.3.6.1.4.1.20044.7.2.3.38 | ||||||||||||
| Smgnt2CfgRestrictUnprivilegeUsers | 1.3.6.1.4.1.20044.7.2.3.38.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Restrict Unprivileged Users Rights :This OID enables the restriction of unprivileged user rights to modify their own password <Help> This parameter enables the restriction of unprivileged user rights to modify their own password | |||||||||||||
| Smgnt2CfgoscDccLinkUpThreshold | 1.3.6.1.4.1.20044.7.2.3.39 | INTEGER (0..255) | RW | ||||||||||
scalar · INTEGER (0..255) · read-write · current OSC/DCC Link Up Thresh. [10-30]s :This OID defines the confirmation threshold to consider an OSC/DCC link as up <Help> This parameter defines the confirmation threshold to consider an OSC/DCC link as up | |||||||||||||
| Smgnt2CfgoscDccLinkDownThreshold | 1.3.6.1.4.1.20044.7.2.3.40 | INTEGER (0..255) | RW | ||||||||||
scalar · INTEGER (0..255) · read-write · current OSC/DCC Link Down Thresh. [2-3]s :This OID defines the confirmation threshold to consider an OSC/DCC link as down <Help> This parameter defines the confirmation threshold to consider an OSC/DCC link as down. | |||||||||||||
| Smgnt2CfgaccountAutoLock | 1.3.6.1.4.1.20044.7.2.3.41 | INTEGER (-1..255) | RW | ||||||||||
scalar · INTEGER (-1..255) · read-write · current Account Auto-Lock [-1 / 1-10] err :This OID defines the number of error password to lock an account. This counter is reset on successful login or after an administrator defined period (see Fail count reset) Set to -1 to disables the feature.<Help> This parameter defines the number of error password to lock an account. This counter is reset on successful login or after an administrator defined period (see Fail count reset) Set to -1 to disables the feature. | |||||||||||||
| Smgnt2CfgfailCountReset | 1.3.6.1.4.1.20044.7.2.3.42 | INTEGER (-1..255) | RW | ||||||||||
scalar · INTEGER (-1..255) · read-write · current Fail Count Reset [-1 / 1-10] hrs :This OID defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful login. Set to -1 to disable the feature.<Help> This parameter defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful login. Set to -1 to disable the feature | |||||||||||||
| Nmgnt2CfgftpMode | 1.3.6.1.4.1.20044.7.2.3.44 | ||||||||||||
| Smgnt2CfgFtpEnable | 1.3.6.1.4.1.20044.7.2.3.44.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current FTP Enable :This OID enables the FTP protocol <Help> This configuration enables the FTP protocol | |||||||||||||
| Nmgnt2CfgtftpMode | 1.3.6.1.4.1.20044.7.2.3.45 | ||||||||||||
| Smgnt2CfgTftpEnable | 1.3.6.1.4.1.20044.7.2.3.45.1 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current TFTP Enable :This OID enables the TFTP protocol <Help> This configuration enables the TFTP protocol | |||||||||||||
| Nmgnt2Traps | 1.3.6.1.4.1.20044.7.3 | ||||||||||||
| !mgnt2TrapApi | 1.3.6.1.4.1.20044.7.3.1 | ||||||||||||
notification · current Api error trap with its number | |||||||||||||
| !mgnt2TrapSwError | 1.3.6.1.4.1.20044.7.3.2 | ||||||||||||
| !mgnt2TrapBoardInserted | 1.3.6.1.4.1.20044.7.3.4 | ||||||||||||
| !mgnt2TrapBoardRemoved | 1.3.6.1.4.1.20044.7.3.5 | ||||||||||||
| !mgnt2TrapRestoreConfDone | 1.3.6.1.4.1.20044.7.3.6 | ||||||||||||
notification · current The Configuration has been restored from the management board
| |||||||||||||
| !mgnt2TrapGlobalPowerFail | 1.3.6.1.4.1.20044.7.3.8 | ||||||||||||
notification · current A global power supply failure has been detected
| |||||||||||||
| !mgnt2TrapFanPowerFail | 1.3.6.1.4.1.20044.7.3.9 | ||||||||||||
notification · current A Fan power supply failure has been detected | |||||||||||||
| !mgnt2TrapGigmPowerFail | 1.3.6.1.4.1.20044.7.3.10 | ||||||||||||
notification · current A power supply default has been detected in the management board | |||||||||||||
| !mgnt2TrapFanFail | 1.3.6.1.4.1.20044.7.3.11 | ||||||||||||
notification · current A Fan failure has been detected | |||||||||||||
| !mgnt2TrapLogFileFull | 1.3.6.1.4.1.20044.7.3.20 | ||||||||||||
notification · current Indicates that the corresponding log file is almost full | |||||||||||||
| !mgnt2TrapAlarm | 1.3.6.1.4.1.20044.7.3.30 | ||||||||||||
notification · current Indicates that an alarm state has changed | |||||||||||||
| !mgnt2TrapEvent | 1.3.6.1.4.1.20044.7.3.31 | ||||||||||||
notification · current Indicates that an event has occured | |||||||||||||
| !mgnt2TrapControl | 1.3.6.1.4.1.20044.7.3.32 | ||||||||||||
notification · current Indicates that a control has been set to the module | |||||||||||||
| !mgnt2TrapConfig | 1.3.6.1.4.1.20044.7.3.33 | ||||||||||||
notification · current Indicates that a config word has been changed | |||||||||||||
| Smgnt2TrapBoardNumber | 1.3.6.1.4.1.20044.7.3.50 | INTEGER (1..16) | RO | ||||||||||
scalar · INTEGER (1..16) · read-only · current This OID gives the slot number of the PM that sent the last trap | |||||||||||||
| Smgnt2TrapSeverity | 1.3.6.1.4.1.20044.7.3.51 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current This OID gives the trap severity | |||||||||||||
| Smgnt2TrapSourcePm | 1.3.6.1.4.1.20044.7.3.52 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current This OID gives the mnemonic of the pm who sent a trap | |||||||||||||
| Smgnt2TrapSourcePortType | 1.3.6.1.4.1.20044.7.3.53 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current This OID gives the type of the port who sent a trap | |||||||||||||
| Smgnt2TrapSourcePortNumber | 1.3.6.1.4.1.20044.7.3.54 | INTEGER (1..16) | RO | ||||||||||
scalar · INTEGER (1..16) · read-only · current This OID gives the port number of the PM that sent the last trap | |||||||||||||
| Smgnt2TrapSourceLabel | 1.3.6.1.4.1.20044.7.3.55 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current This OID gives the label of the alarm who sent a trap | |||||||||||||
| Smgnt2TrapSourceValue | 1.3.6.1.4.1.20044.7.3.56 | EkiOnOff | RO | ||||||||||
scalar · EkiOnOff · read-only · current This OID gives the value of the alarm who sent a trap | |||||||||||||
| Smgnt2TrapEventLabel | 1.3.6.1.4.1.20044.7.3.57 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current This OID gives the label of the event | |||||||||||||
| Smgnt2TrapNodeControllerIpAddress | 1.3.6.1.4.1.20044.7.3.58 | IpAddress | RO | ||||||||||
scalar · IpAddress · read-only · current This OID gives the IP address of the Node Controller | |||||||||||||
| Smgnt2TrapChassisId | 1.3.6.1.4.1.20044.7.3.59 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current This OID gives the chassis ID | |||||||||||||
| Nmgnt2SoftwareManagement | 1.3.6.1.4.1.20044.7.4 | ||||||||||||
| Tmgnt2DwlUploadingTable | 1.3.6.1.4.1.20044.7.4.1 | NA | deprecated | ||||||||||
table · not-accessible · deprecated SNMP Agent SW packages in ram: List of the SNMP agent software packages available in /ram for download on the Chassis managment module flash | |||||||||||||
| Rmgnt2DwlUploadingEntry | 1.3.6.1.4.1.20044.7.4.1.1 | NA | deprecated | ||||||||||
row · not-accessible · deprecated Row definition for the package uploading table
| |||||||||||||
| Cmgnt2IndexUpload | 1.3.6.1.4.1.20044.7.4.1.1.1 | Integer32 (0..4) | RO | deprecated | |||||||||
column · Integer32 (0..4) · read-only · deprecated Index for uploading table | |||||||||||||
| Cmgnt2DwlUploadFileName | 1.3.6.1.4.1.20044.7.4.1.1.2 | DisplayString | RO | deprecated | |||||||||
column · DisplayString · read-only · deprecated Package filename in RAM:This OID gives the name of the SNMP agent software packages in RAM | |||||||||||||
| Cmgnt2ImmediateReplacement | 1.3.6.1.4.1.20044.7.4.1.1.3 | EkiState | RW | deprecated | |||||||||
column · EkiState · read-write · deprecated Immediat Agent Replacement:This OID indicates to switch to selected SNMP agent immediately or after reset of the MGNT2 | |||||||||||||
| Cmgnt2FileUpload | 1.3.6.1.4.1.20044.7.4.1.1.4 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Agent File Upload:This OID validates the upload of the SNMP agent from RAM to FLASH | |||||||||||||
| Cmgnt2DeletePackageFromRam | 1.3.6.1.4.1.20044.7.4.1.1.5 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Delete Package from RAM:This OID requests to delete the SNMP Agent SW package from RAM | |||||||||||||
| Cmgnt2FlashingInProgress | 1.3.6.1.4.1.20044.7.4.1.1.6 | EkiOnOff | RO | deprecated | |||||||||
column · EkiOnOff · read-only · deprecated Flashing in Progress:This OID indicates whether there is a file upload to FLASH in progress | |||||||||||||
| Tmgnt2DwlPackageTable | 1.3.6.1.4.1.20044.7.4.2 | NA | deprecated | ||||||||||
table · not-accessible · deprecated List of SNMP agent software packages present in flash memory | |||||||||||||
| Rmgnt2DwlPackageEntry | 1.3.6.1.4.1.20044.7.4.2.1 | NA | deprecated | ||||||||||
row · not-accessible · deprecated Row definition for the package management table
| |||||||||||||
| Cmgnt2IndexPackage | 1.3.6.1.4.1.20044.7.4.2.1.1 | Integer32 (0..4) | RO | deprecated | |||||||||
column · Integer32 (0..4) · read-only · deprecated Index for package management table | |||||||||||||
| Cmgnt2DwlPackageFileName | 1.3.6.1.4.1.20044.7.4.2.1.2 | DisplayString | RO | deprecated | |||||||||
column · DisplayString · read-only · deprecated Package File name in FLASH:This OID gives the name of the SNMP agent software package in FLASH | |||||||||||||
| Cmgnt2ExtractedPack | 1.3.6.1.4.1.20044.7.4.2.1.3 | EkiOnOff | RO | deprecated | |||||||||
column · EkiOnOff · read-only · deprecated Extracted SNMP agent software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted | |||||||||||||
| Cmgnt2SwitchTo | 1.3.6.1.4.1.20044.7.4.2.1.4 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Switch to package:This OID activates the SNMP Agent Software package | |||||||||||||
| Cmgnt2Immediate | 1.3.6.1.4.1.20044.7.4.2.1.5 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Immediate SNMP agent activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next reset | |||||||||||||
| Cmgnt2DeletePackageFromFlash | 1.3.6.1.4.1.20044.7.4.2.1.6 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Delete package from FLASH:This OID deletes the SNMP agent software package from the FLASH | |||||||||||||
| Cmgnt2PackageExtractionInProgress | 1.3.6.1.4.1.20044.7.4.2.1.7 | EkiOnOff | RO | deprecated | |||||||||
column · EkiOnOff · read-only · deprecated Package extraction in progress:This OID indicates that a SNMP agent software activation is in progress | |||||||||||||
| Smgnt2DwlUploadingTableUpdate | 1.3.6.1.4.1.20044.7.4.3 | EkiOnOff | RW | deprecated | |||||||||
scalar · EkiOnOff · read-write · deprecated Uploading Table update:This OID updates the contents of the uploading table | |||||||||||||
| Tmgnt2LoadPMTable | 1.3.6.1.4.1.20044.7.4.4 | NA | deprecated | ||||||||||
table · not-accessible · deprecated List of the PM module software files (GW/SW) present on the repository | |||||||||||||
| Rmgnt2LoadPMEntry | 1.3.6.1.4.1.20044.7.4.4.1 | NA | deprecated | ||||||||||
| Cmgnt2LoadPMIndex | 1.3.6.1.4.1.20044.7.4.4.1.1 | Integer32 (0..32) | RO | deprecated | |||||||||
column · Integer32 (0..32) · read-only · deprecated Index for Load article table | |||||||||||||
| Cmgnt2LoadFileName | 1.3.6.1.4.1.20044.7.4.4.1.2 | DisplayString | RO | deprecated | |||||||||
column · DisplayString · read-only · deprecated PM Upgrade filename:This OID gives the name of the file | |||||||||||||
| Cmgnt2LoadFileType | 1.3.6.1.4.1.20044.7.4.4.1.3 | EkiLoadGWSW | RO | deprecated | |||||||||
column · EkiLoadGWSW · read-only · deprecated PM upgrade file type:This OID gives the type of file (gateware or software) | |||||||||||||
| Cmgnt2LoadState | 1.3.6.1.4.1.20044.7.4.4.1.4 | EkiLoadState | RO | deprecated | |||||||||
column · EkiLoadState · read-only · deprecated PM upgrade status:This OID gives the status of the selected Load file | |||||||||||||
| Cmgnt2LoadModuleNumber | 1.3.6.1.4.1.20044.7.4.4.1.5 | Integer32 (1..8) | RW | deprecated | |||||||||
column · Integer32 (1..8) · read-write · deprecated PM ugprade target:This OID defines the slot number of the PM to upgrade | |||||||||||||
| Cmgnt2LoadResetMethod | 1.3.6.1.4.1.20044.7.4.4.1.6 | EkiLoadPermutMethod | RW | deprecated | |||||||||
column · EkiLoadPermutMethod · read-write · deprecated PM upgrade reset method:This OID defines the reset method (manual, immediate or scheduled) | |||||||||||||
| Cmgnt2LoadResetMode | 1.3.6.1.4.1.20044.7.4.4.1.7 | EkiLoadPermutMode | RW | deprecated | |||||||||
column · EkiLoadPermutMode · read-write · deprecated PM upgrade reset mode:This OID defines the type of reset (cold or warm) | |||||||||||||
| Cmgnt2LoadBankNumber | 1.3.6.1.4.1.20044.7.4.4.1.8 | Integer32 (0..4) | RW | deprecated | |||||||||
column · Integer32 (0..4) · read-write · deprecated PM upgrade bank number:This OID defines the target bank number in the PM's flash | |||||||||||||
| Cmgnt2LoadDownloadProgress | 1.3.6.1.4.1.20044.7.4.4.1.9 | Integer32 (0..100) | RO | deprecated | |||||||||
column · Integer32 (0..100) · read-only · deprecated PM upgrade progress:This OID gives the upgrade progress (percentage) | |||||||||||||
| Cmgnt2LoadTransfer | 1.3.6.1.4.1.20044.7.4.4.1.10 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated PM upgrade transfer:This OID launchs the transfer of the associated file to the selected PM's flash | |||||||||||||
| Cmgnt2LoadDelete | 1.3.6.1.4.1.20044.7.4.4.1.11 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated PM upgrade delete file:This OID deletes the associated file from the RAM of the management board | |||||||||||||
| Smgnt2LoadPMTableUpdate | 1.3.6.1.4.1.20044.7.4.5 | EkiOnOff | RW | deprecated | |||||||||
scalar · EkiOnOff · read-write · deprecated Load PM Table update:This OID updates the contents of the Load table | |||||||||||||
| Tmgnt2DwlEkicraftPkgTable | 1.3.6.1.4.1.20044.7.4.6 | NA | deprecated | ||||||||||
table · not-accessible · deprecated List of Ekicraft software packages present in flash memory | |||||||||||||
| Rmgnt2DwlEkicraftPkgEntry | 1.3.6.1.4.1.20044.7.4.6.1 | NA | deprecated | ||||||||||
row · not-accessible · deprecated Row definition for the package management table | |||||||||||||
| Cmgnt2IndexEkicraftPkg | 1.3.6.1.4.1.20044.7.4.6.1.1 | Integer32 (0..4) | RO | deprecated | |||||||||
column · Integer32 (0..4) · read-only · deprecated Index for Ekicraft package management table | |||||||||||||
| Cmgnt2DwlEkicraftPkgFileName | 1.3.6.1.4.1.20044.7.4.6.1.2 | DisplayString | RO | deprecated | |||||||||
column · DisplayString · read-only · deprecated Package File name in FLASH:This OID gives the name of the Ekicraft software package in FLASH | |||||||||||||
| Cmgnt2DwlEkicraftExtractedPack | 1.3.6.1.4.1.20044.7.4.6.1.3 | EkiOnOff | RO | deprecated | |||||||||
column · EkiOnOff · read-only · deprecated Extracted Ekicraft software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted | |||||||||||||
| Cmgnt2DwlEkicraftSwitchTo | 1.3.6.1.4.1.20044.7.4.6.1.4 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Switch to package:This OID activates the Ekicraft Software package | |||||||||||||
| Cmgnt2DwlEkicraftImmediate | 1.3.6.1.4.1.20044.7.4.6.1.5 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Immediate Ekicraft activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next reset | |||||||||||||
| Cmgnt2DeleteEkicraftPkgFromFlash | 1.3.6.1.4.1.20044.7.4.6.1.6 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Delete package from FLASH:This OID deletes the Ekicraft software package from the FLASH | |||||||||||||
| Cmgnt2EkicraftPkgExtractionInProgress | 1.3.6.1.4.1.20044.7.4.6.1.7 | EkiOnOff | RO | deprecated | |||||||||
column · EkiOnOff · read-only · deprecated Package extraction in progress:This OID indicates that an Ekicraft activation is in progress | |||||||||||||
| Nmgnt2ConfigManagement | 1.3.6.1.4.1.20044.7.5 | ||||||||||||
| Tmgnt2CnfUploadConfigFilesTable | 1.3.6.1.4.1.20044.7.5.1 | NA | deprecated | ||||||||||
table · not-accessible · deprecated List of configuration files uploaded to RAM | |||||||||||||
| Rmgnt2CnfUploadConfigFilesEntry | 1.3.6.1.4.1.20044.7.5.1.1 | NA | deprecated | ||||||||||
row · not-accessible · deprecated Row definition for the package uploading table | |||||||||||||
| Cmgnt2CnfUploadConfigIndex | 1.3.6.1.4.1.20044.7.5.1.1.1 | Integer32 (0..16) | RO | deprecated | |||||||||
column · Integer32 (0..16) · read-only · deprecated Index of config files | |||||||||||||
| Cmgnt2CnfConfigFileName | 1.3.6.1.4.1.20044.7.5.1.1.2 | DisplayString | RO | deprecated | |||||||||
column · DisplayString · read-only · deprecated Configuration filename in RAM:This OID gives the name of the configuration file in RAM | |||||||||||||
| Cmgnt2CnfConfigSlot | 1.3.6.1.4.1.20044.7.5.1.1.3 | Integer32 (0..3) | RW | deprecated | |||||||||
column · Integer32 (0..3) · read-write · deprecated Configuration target:This OID defines the target slot number for the configuration file | |||||||||||||
| Cmgnt2CnfConfigUpload | 1.3.6.1.4.1.20044.7.5.1.1.4 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Configuration Upload:This OID uploads the configuration file to the specified slot number in the PM FLASH | |||||||||||||
| Cmgnt2CnfDeleteConfigFile | 1.3.6.1.4.1.20044.7.5.1.1.5 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Configuration delete from RAM:This OID deletes the configuration file from RAM | |||||||||||||
| Tmgnt2CnfManageConfigFilesTable | 1.3.6.1.4.1.20044.7.5.2 | NA | deprecated | ||||||||||
table · not-accessible · deprecated List of configuration files uploaded to RAM | |||||||||||||
| Rmgnt2CnfManageConfigFilesEntry | 1.3.6.1.4.1.20044.7.5.2.1 | NA | deprecated | ||||||||||
row · not-accessible · deprecated Row definition for the package uploading table | |||||||||||||
| Cmgnt2CnfManageConfigIndex | 1.3.6.1.4.1.20044.7.5.2.1.1 | Integer32 (0..16) | RO | deprecated | |||||||||
column · Integer32 (0..16) · read-only · deprecated Index of config file slots | |||||||||||||
| Cmgnt2CnfManageConfigFileID | 1.3.6.1.4.1.20044.7.5.2.1.2 | DisplayString | RW | deprecated | |||||||||
column · DisplayString · read-write · deprecated Configuration file ID in FLASH:This OID gives the ID of the configuration file in MGNT2 FLASH | |||||||||||||
| Cmgnt2CnfManageConfigFileName | 1.3.6.1.4.1.20044.7.5.2.1.3 | DisplayString | RW | deprecated | |||||||||
column · DisplayString · read-write · deprecated Configuration file name in FLASH:This OID gives the name of the configuration file in MGNT2 FLASH | |||||||||||||
| Cmgnt2CnfModuleSlotNumber | 1.3.6.1.4.1.20044.7.5.2.1.4 | Integer32 (3..6) | RW | deprecated | |||||||||
column · Integer32 (3..6) · read-write · deprecated Configuration target:This OID defines the target module slot number for the configuration file | |||||||||||||
| Cmgnt2CnfBackupConfig | 1.3.6.1.4.1.20044.7.5.2.1.5 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Configuration backup:This OID backups the configuration of the specified module to the selected file in MGNT2 FLASH | |||||||||||||
| Cmgnt2CnfRestoreConfig | 1.3.6.1.4.1.20044.7.5.2.1.6 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Configuration Restore:This OID restores the configuration of the specified module from the selected file in MGNT2 FLASH | |||||||||||||
| Cmgnt2CnfExportConfig | 1.3.6.1.4.1.20044.7.5.2.1.7 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Configuration Export:This OID exports the selected file in MGNT2 FLASH to a file in RAM | |||||||||||||
| Cmgnt2CnfDeleteConfig | 1.3.6.1.4.1.20044.7.5.2.1.8 | EkiOnOff | RW | deprecated | |||||||||
column · EkiOnOff · read-write · deprecated Configuration delete from FLASH:This OID deletes the configuration file from the MGNT2 FLASH | |||||||||||||
| Nmgnt2RemoteInventory | 1.3.6.1.4.1.20044.7.6 | ||||||||||||
| Smgnt2RinvHwPlatform | 1.3.6.1.4.1.20044.7.6.1 | DisplayString | RW | MGNT HARDWARE
Vendor Name : … | |||||||||
scalar · DisplayString · read-write · current Chassis Hardware inventory:This OID gives the Hardware inventory of the Mgnt2 management module Example values from LibreNMS test devices
| |||||||||||||
| Smgnt2RinvSoftwarePackage | 1.3.6.1.4.1.20044.7.6.2 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Chassis Software package inventory:this OID gives the Software package inventory of the Mgnt2 management module | |||||||||||||
| Smgnt2RinvGateware | 1.3.6.1.4.1.20044.7.6.3 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Chassis Gateware inventory:This OID gives the gateware inventory of the Mgnt2 management module | |||||||||||||
| Smgnt2RinvAgent | 1.3.6.1.4.1.20044.7.6.4 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Chassis Software inventory:This OID gives the software inventory of the Mgnt2 management module | |||||||||||||
| Smgnt2RinvCraft | 1.3.6.1.4.1.20044.7.6.5 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Chassis Craft inventory:This OID gives the craft inventory of the Mgnt2 management module | |||||||||||||
| Smgnt2RinvLinux | 1.3.6.1.4.1.20044.7.6.6 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Chassis Linux inventory:This OID gives the linux inventory of the Mgnt2 management module | |||||||||||||
| Tmgnt2GigmPlugInTable | 1.3.6.1.4.1.20044.7.6.7 | NA | |||||||||||
table · not-accessible · current List of Plug-ins present | |||||||||||||
| Rmgnt2GigmPlugInEntry | 1.3.6.1.4.1.20044.7.6.7.1 | NA | |||||||||||
| Cmgnt2IndexPlugIns | 1.3.6.1.4.1.20044.7.6.7.1.1 | Integer32 (1..32) | RO | ||||||||||
column · Integer32 (1..32) · read-only · current Index for PMs table | |||||||||||||
| Cmgnt2PlugInRinv | 1.3.6.1.4.1.20044.7.6.7.1.2 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Plug-in RI:This OID gives the remote inventory of the plug-in | |||||||||||||
| Cmgnt2PollingPresent | 1.3.6.1.4.1.20044.7.6.7.1.3 | EkiPlugInState | RO | ||||||||||
column · EkiPlugInState · read-only · current Polling present:This OID gives the presence of the polling plug-in | |||||||||||||
| Cmgnt2SnmpPresent | 1.3.6.1.4.1.20044.7.6.7.1.4 | EkiPlugInState | RO | ||||||||||
column · EkiPlugInState · read-only · current Snmp present:This OID gives the presence of the snmp plug-in | |||||||||||||
| Smgnt2RinvBackpanel | 1.3.6.1.4.1.20044.7.6.8 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Backpanel inventory:This OID gives the Backpanel inventory of the chassis | |||||||||||||
| Smgnt2RinvFan | 1.3.6.1.4.1.20044.7.6.9 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current Fan inventory:This OID gives the fan inventory of the chassis | |||||||||||||
| Smgnt2RinvUboot | 1.3.6.1.4.1.20044.7.6.10 | DisplayString | RW | ||||||||||
scalar · DisplayString · read-write · current U-Boot inventory:This OID gives the U-Boot inventory | |||||||||||||
| Nmgnt2ErrorCounters | 1.3.6.1.4.1.20044.7.7 | ||||||||||||
| Tmgnt2GigmErrorCounterTable | 1.3.6.1.4.1.20044.7.7.1 | NA | |||||||||||
table · not-accessible · current List of error counters | |||||||||||||
| Rmgnt2GigmErrorCounterEntry | 1.3.6.1.4.1.20044.7.7.1.1 | NA | |||||||||||
row · not-accessible · current Row Definition for the error counters table | |||||||||||||
| Cmgnt2IndexErrorCounter | 1.3.6.1.4.1.20044.7.7.1.1.1 | Integer32 (1..32) | RO | ||||||||||
column · Integer32 (1..32) · read-only · current Index for error counters table | |||||||||||||
| Cmgnt2ErrorCounterSlotNumber | 1.3.6.1.4.1.20044.7.7.1.1.2 | Integer32 | RO | ||||||||||
column · Integer32 · read-only · current Slot number:This OID gives the slot number for the corresponding counter | |||||||||||||
| Cmgnt2ErrorCounterValue | 1.3.6.1.4.1.20044.7.7.1.1.3 | Integer32 | RO | ||||||||||
column · Integer32 · read-only · current Count value:This OID gives the value of the error counter | |||||||||||||
| Smgnt2GigmResetErrorCounters | 1.3.6.1.4.1.20044.7.7.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current Reset error counters:This OID reset the error counters to 0 | |||||||||||||
| Nmgnt2Perf | 1.3.6.1.4.1.20044.7.8 | ||||||||||||
| Tmgnt2PerfCapabilityTable | 1.3.6.1.4.1.20044.7.8.1 | NA | |||||||||||
table · not-accessible · current List of Perf capability of PMs plugged in the Chassis | |||||||||||||
| Rmgnt2PerfCapabilityEntry | 1.3.6.1.4.1.20044.7.8.1.1 | NA | |||||||||||
row · not-accessible · current Row Definition for the Perf capability table | |||||||||||||
| Cmgnt2PerfCapIndexBoards | 1.3.6.1.4.1.20044.7.8.1.1.1 | Integer32 (1..32) | RO | ||||||||||
column · Integer32 (1..32) · read-only · current Index for Perf cap table | |||||||||||||
| Cmgnt2PerfCapPosition | 1.3.6.1.4.1.20044.7.8.1.1.2 | Integer32 (1..32) | RO | ||||||||||
column · Integer32 (1..32) · read-only · current PM Slot number:This OID gives the slot number in which the PM is plugged | |||||||||||||
| Cmgnt2PerfCapName | 1.3.6.1.4.1.20044.7.8.1.1.3 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current PM name:This OID gives the name of the PM plugged in the Mgnt2 | |||||||||||||
| Cmgnt2PerfCapStatus | 1.3.6.1.4.1.20044.7.8.1.1.4 | EkiOnOff | RO | ||||||||||
column · EkiOnOff · read-only · current Status of the perf cap:This OID gives the capability of the pm to do performance | |||||||||||||
| Cmgnt2PerfCapOidEnable | 1.3.6.1.4.1.20044.7.8.1.1.5 | OBJECT IDENTIFIER | RO | ||||||||||
column · OBJECT IDENTIFIER · read-only · current OID of the object perf enable:This OID gives the OID of the perf enable object of the correspondind mib of the module | |||||||||||||
| Smgnt2GigmPerf15minSync | 1.3.6.1.4.1.20044.7.8.2 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current 15 min sync perf : this oid send a 15min sync to all modules | |||||||||||||
| Smgnt2GigmPerf24hSync | 1.3.6.1.4.1.20044.7.8.3 | EkiOnOff | RW | ||||||||||
scalar · EkiOnOff · read-write · current 15 min sync perf : this oid send a 24h sync to all modules | |||||||||||||
| Smgnt2PerfResyncNMS | 1.3.6.1.4.1.20044.7.8.4 | Mgnt2PerfResyncValues | RW | ||||||||||
scalar · Mgnt2PerfResyncValues · read-write · current Resync Perf : this oid allows to create an historical perf file for all modules | |||||||||||||
Textual conventions
EkiPlugInStateINTEGERabsent(0)loaded(1)symbolError(3)versionError(2)Plug-in state
Mgnt2AckModeINTEGERmodeA(1)modeB(2)different modes to acknowledge alarms
Mgnt2AuthTypeValuesINTEGERauthLDAP(2)authLocal(0)authRADIUS(1)Various types of authentication processes
Mgnt2CliAccessValuesINTEGERcliBySSH(1)cliByTelnet(2)noCliByEthernet(0)different type of access by ethernet for the CLI
Mgnt2CraftAccessValuesINTEGERcraftEnable(1)craftEnableHttps(2)noCraftAccess(0)enables access to the CRAFT
Mgnt2DccAccessValuesINTEGERmode1Slots2s4s6s8s10(0)mode2Slots2s6s10s14s18(1)different modes for the Dcc access
Mgnt2LogFileModeINTEGERdisabled(0)linear(1)rotary(2)different modes for the log files
Mgnt2MasterEthModeINTEGERdhcp(2)static(1)different modes for the Master
Mgnt2NetModeINTEGERgateway(2)switch(1)different modes for the network management
Mgnt2PerfResyncValuesINTEGERperfResyncDelete(4)perfResyncIdle(1)perfResyncReady(3)perfResyncSync(2)different modes for the trap generation
Mgnt2SlotStatusINTEGERpmLoad(3)pmNotReady(6)pmPassive(4)pmReady(1)pmReset(2)pmUnknown(5)slotEmpty(0)Status of the slot
Mgnt2SubnetEthModeINTEGERdhcp(2)static(1)different modes for the Subnet
Mgnt2TrapModeValuesINTEGERdetailedTrap(1)nmsTrap(2)syntheticTrap(0)different modes for the trap generation
Traps / Notifications
- mgnt2TrapAlarm
1.3.6.1.4.1.20044.7.3.30 - mgnt2TrapApi
1.3.6.1.4.1.20044.7.3.1 - mgnt2TrapBoardInserted
1.3.6.1.4.1.20044.7.3.4 - mgnt2TrapBoardRemoved
1.3.6.1.4.1.20044.7.3.5 - mgnt2TrapConfig
1.3.6.1.4.1.20044.7.3.33 - mgnt2TrapControl
1.3.6.1.4.1.20044.7.3.32 - mgnt2TrapEvent
1.3.6.1.4.1.20044.7.3.31 - mgnt2TrapFanFail
1.3.6.1.4.1.20044.7.3.11 - mgnt2TrapFanPowerFail
1.3.6.1.4.1.20044.7.3.9 - mgnt2TrapGigmPowerFail
1.3.6.1.4.1.20044.7.3.10 - mgnt2TrapGlobalPowerFail
1.3.6.1.4.1.20044.7.3.8 - mgnt2TrapLogFileFull
1.3.6.1.4.1.20044.7.3.20 - mgnt2TrapRestoreConfDone
1.3.6.1.4.1.20044.7.3.6 - mgnt2TrapSwError
1.3.6.1.4.1.20044.7.3.2