DLINKSW-ENTITY-EXT-MIB
D-Link Systems, Inc.This MIB module provides essential information about the system and defines the managed objects that support the monitoring of alarms generated by physical entities, including temperature sensors, fans and power supplies.
snmptranslate -m DLINKSW-ENTITY-EXT-MIB -Tpsnmpwalk -v2c -c <community> -m DLINKSW-ENTITY-EXT-MIB <host> 1.3.6.1.4.1.171.11.165.1000.5Imports
| DLINK-ID-REC-MIB | dlink-DGS-1250SeriesProj, dlink-dgs-1250-Common, dlink-mgmt |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IdlinkSwEntityExtMIB | 1.3.6.1.4.1.171.11.165.1000.5 | ||||||||||||||||
identity This MIB module provides essential information about the system and defines the managed objects that support the monitoring of alarms generated by physical entities, including temperature sensors, fans and power supplies. | |||||||||||||||||
| NdEntityExtNotifications | 1.3.6.1.4.1.171.11.165.1000.5.0 | ||||||||||||||||
| !dEntityExtFanStatusChg | 1.3.6.1.4.1.171.11.165.1000.5.0.1 | ||||||||||||||||
notification · current This trap indicates a fan fails (dEntityExtEnvFanStatus is 'fault') or recovers (dEntityExtEnvFanStatus is 'ok'). | |||||||||||||||||
| !dEntityExtThermalStatusChg | 1.3.6.1.4.1.171.11.165.1000.5.0.2 | ||||||||||||||||
notification · current This trap indicates a thermal alarms (dEntityExtEnvTempStatus is 'abnormal') or recovers (dEntityExtEnvTempStatus is 'ok'). | |||||||||||||||||
| !dEntityExtPowerStatusChg | 1.3.6.1.4.1.171.11.165.1000.5.0.3 | ||||||||||||||||
notification · current This trap indicates a power module fails, recovers or is removed. | |||||||||||||||||
| !dEntityExtAirFlowChg | 1.3.6.1.4.1.171.11.165.1000.5.0.4 | ||||||||||||||||
notification · current This trap is triggered when the air flow status is changed from 'ok' to 'abnormal' and vice versa. dEntityExtEnvAirFlowStatus indicates the current (new) fan air flow state. | |||||||||||||||||
| !dEntityExtFactoryResetButton | 1.3.6.1.4.1.171.11.165.1000.5.0.5 | ||||||||||||||||
notification · current This trap is triggered when the factory reset button was pressed.
| |||||||||||||||||
| NdEntityExtObjects | 1.3.6.1.4.1.171.11.165.1000.5.1 | ||||||||||||||||
| NdEntityExtEnvObjects | 1.3.6.1.4.1.171.11.165.1000.5.1.1 | ||||||||||||||||
| TdEntityExtEnvTempTable | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1 | NA | |||||||||||||||
table · not-accessible · current The table consists of a list of temperature information. | |||||||||||||||||
| RdEntityExtEnvTempEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1 | NA | |||||||||||||||
row · not-accessible · current An entry represents the temperature status of a testpoint. | |||||||||||||||||
| CdEntityExtEnvTempUnitId | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1.1 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID at which the testpoint is located. | |||||||||||||||||
| CdEntityExtEnvTempIndex | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1.2 | Integer32 (1..2147483647) | NA | ||||||||||||||
column · Integer32 (1..2147483647) · not-accessible · current This object is used to uniquely identify the testpoint within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning. | |||||||||||||||||
| CdEntityExtEnvTempDescr | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1.3 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This object provides human-sensible identification for the testpoint. e.g. 'Inlet', 'Center', 'Outlet'. | |||||||||||||||||
| CdEntityExtEnvTempCurrent | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1.4 | Integer32 | RO | 30 | |||||||||||||
column · Integer32 · read-only · current This object indicates the current measurement of the testpoint.
Example values from LibreNMS test devices
| |||||||||||||||||
| CdEntityExtEnvTempThresholdLow | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1.5 | Integer32 | RW | ||||||||||||||
column · Integer32 · read-write · current The object indicates the minimum acceptable reading of the testpoint in degrees Celsius.
| |||||||||||||||||
| CdEntityExtEnvTempThresholdHigh | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1.6 | Integer32 | RW | ||||||||||||||
column · Integer32 · read-write · current The object indicates the maximum acceptable reading of the testpoint in degrees Celsius.
| |||||||||||||||||
| CdEntityExtEnvTempStatus | 1.3.6.1.4.1.171.11.165.1000.5.1.1.1.1.7 | INTEGER | RO | ok(1) | |||||||||||||
column · INTEGER · read-only · current The object indicates the current temperature is over the thresholds or not. 'abnormal' indicates the temperature is over the thresholds. 'ok' indicates the temperature is not over the thresholds.
Example values from LibreNMS test devices
| |||||||||||||||||
| TdEntityExtEnvFanTable | 1.3.6.1.4.1.171.11.165.1000.5.1.1.2 | NA | |||||||||||||||
table · not-accessible · current The table is used to display the status of fans. | |||||||||||||||||
| RdEntityExtEnvFanEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.1.2.1 | NA | |||||||||||||||
row · not-accessible · current An entry represents a fan status. | |||||||||||||||||
| CdEntityExtEnvFanUnitId | 1.3.6.1.4.1.171.11.165.1000.5.1.1.2.1.1 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID at which the fan is located. | |||||||||||||||||
| CdEntityExtEnvFanIndex | 1.3.6.1.4.1.171.11.165.1000.5.1.1.2.1.2 | Integer32 (1..2147483647) | NA | ||||||||||||||
column · Integer32 (1..2147483647) · not-accessible · current This object is used to uniquely identify the fan within a unit/slot. This index is for SNMP purposes only, and has no intrinsic meaning. | |||||||||||||||||
| CdEntityExtEnvFanDescr | 1.3.6.1.4.1.171.11.165.1000.5.1.1.2.1.3 | DisplayString (SIZE (0..32)) | RO | Right Fan 1 | |||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This object provides human-sensible identification for the fan. e.g. 'Left 1' for the first fan on the left. Example values from LibreNMS test devices
| |||||||||||||||||
| CdEntityExtEnvFanStatus | 1.3.6.1.4.1.171.11.165.1000.5.1.1.2.1.4 | INTEGER | RO | ok(1) | |||||||||||||
column · INTEGER · read-only · current This object indicates the fan status.
Example values from LibreNMS test devices
| |||||||||||||||||
| TdEntityExtEnvPowerTable | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3 | NA | |||||||||||||||
table · not-accessible · current The table is used to display the status of the power modules. | |||||||||||||||||
| RdEntityExtEnvPowerEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3.1 | NA | |||||||||||||||
row · not-accessible · current An entry contains the information of a power module. | |||||||||||||||||
| CdEntityExtEnvPowerUnitId | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3.1.1 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID at which the power module is located. | |||||||||||||||||
| CdEntityExtEnvPowerIndex | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3.1.2 | Unsigned32 (1..2147483647) | NA | ||||||||||||||
column · Unsigned32 (1..2147483647) · not-accessible · current This object indicates the ID of the power module. This object is used to uniquely identify the power module. This index is for SNMP purposes only, and has no intrinsic meaning. | |||||||||||||||||
| CdEntityExtEnvPowerDescr | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3.1.3 | DisplayString (SIZE (0..32)) | RO | Power 1 | |||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This object provides human-sensible information for the power module. e.g. '#1 (internal)', '#2 (external)'. Example values from LibreNMS test devices
| |||||||||||||||||
| CdEntityExtEnvPowerUsedPower | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3.1.4 | Unsigned32 | RO | 0 | |||||||||||||
column · Unsigned32 · read-only · current This object indicates the amount of the power that has been allocated.
Example values from LibreNMS test devices
| |||||||||||||||||
| CdEntityExtEnvPowerMaxPower | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3.1.5 | Unsigned32 | RO | 0 | |||||||||||||
column · Unsigned32 · read-only · current This object indicates maximum power which the power module can supply.
Example values from LibreNMS test devices
| |||||||||||||||||
| CdEntityExtEnvPowerStatus | 1.3.6.1.4.1.171.11.165.1000.5.1.1.3.1.6 | INTEGER | RO | inOperation(1) | |||||||||||||
column · INTEGER · read-only · current This object indicates the status of the power.
Example values from LibreNMS test devices
| |||||||||||||||||
| TdEntityExtEnvAirFlowTable | 1.3.6.1.4.1.171.11.165.1000.5.1.1.4 | NA | |||||||||||||||
table · not-accessible · current The table is used to display the status of the air flow function. | |||||||||||||||||
| RdEntityExtEnvAirFlowEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.1.4.1 | NA | |||||||||||||||
row · not-accessible · current An entry contains the information of the air flow function. | |||||||||||||||||
| CdEntityExtEnvAirFlowUnitId | 1.3.6.1.4.1.171.11.165.1000.5.1.1.4.1.1 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID at which the air flow module is located. | |||||||||||||||||
| CdEntityExtEnvAirFlowStatus | 1.3.6.1.4.1.171.11.165.1000.5.1.1.4.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This object indicates the status of the air flow.
The fans' air flow direction must match the system's air flow
direction to form an integrated air flow.
For example: In DXS-3600, the normal fans' air flow direction must
match the power fan's air flow direction.
The power fan blow the cold air from outside to inside, all the
normal fans must blow the hot air from inside to outside. Or the
power fan blow the hot air from inside to outside, all the normal
fans must blow the cold air from outside to inside.
If one or more fans' air flow direction does not match the system's
air flow direction, it will form an abnormal air flow. Then this log
message will be triggered.
ok(1) : A recover event indicates the air flow back to normal.
abnormal(2): An alarm event indicates the air flow detects abnormal.
| |||||||||||||||||
| NdEntityExtEnvTrap | 1.3.6.1.4.1.171.11.165.1000.5.1.2 | ||||||||||||||||
| SdEntityExtEnvNotifyEnable | 1.3.6.1.4.1.171.11.165.1000.5.1.2.1 | Bits | RW | ||||||||||||||
scalar · Bits · read-write · current This object indicates whether a specified notification is enabled
or not. If a bit corresponding to a notification is set to 1, then
the specified notification can be generated.
fan(0) - fan trap state for warning fan event (fan failed or fan
recover).
power(1) - power trap state for warning power event (power failure
or power recovery).
temperature(2) - temperature trap state for warning temperature event
(temperature exceeds the thresholds or temperature recover).
| |||||||||||||||||
| TdEntityExtUnitTable | 1.3.6.1.4.1.171.11.165.1000.5.1.3 | NA | |||||||||||||||
table · not-accessible · current The table is used to display information of units. | |||||||||||||||||
| RdEntityExtUnitEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.3.1 | NA | |||||||||||||||
row · not-accessible · current An entry contains essential information of a unit.
| |||||||||||||||||
| CdEntityExtUnitIndex | 1.3.6.1.4.1.171.11.165.1000.5.1.3.1.1 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID. | |||||||||||||||||
| CdEntityExtUnitStatus | 1.3.6.1.4.1.171.11.165.1000.5.1.3.1.2 | INTEGER | RO | ||||||||||||||
column · INTEGER · read-only · current This object represents the status of the unit:
ok(1) - This indicates the unit is okay.
failed(2) - This indicates the unit fails due to some reason.
empty(3) - This indicates that the unit is provisioned but
currently not installed.
| |||||||||||||||||
| CdEntityExtUnitUpTime | 1.3.6.1.4.1.171.11.165.1000.5.1.3.1.3 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current This object provides the up time in units of seconds for the unit since it was last re-initialized.
| |||||||||||||||||
| TdEntityExtMemoryUtilTable | 1.3.6.1.4.1.171.11.165.1000.5.1.4 | NA | |||||||||||||||
table · not-accessible · current The table is used to display memory utilization information. | |||||||||||||||||
| RdEntityExtMemoryUtilEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.4.1 | NA | |||||||||||||||
row · not-accessible · current An entry contains memory utilization information. | |||||||||||||||||
| CdEntityExtMemUtilUnitId | 1.3.6.1.4.1.171.11.165.1000.5.1.4.1.1 | Integer32 (1..65535) | NA | ||||||||||||||
column · Integer32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID. | |||||||||||||||||
| CdEntityExtMemUtilType | 1.3.6.1.4.1.171.11.165.1000.5.1.4.1.2 | INTEGER | NA | ||||||||||||||
column · INTEGER · not-accessible · current The object indicates the memory type of the entry.
| |||||||||||||||||
| CdEntityExtMemUtilTotal | 1.3.6.1.4.1.171.11.165.1000.5.1.4.1.3 | Unsigned32 | RO | 243268 | |||||||||||||
column · Unsigned32 · read-only · current This object indicates the total memory size of the entry.
Example values from LibreNMS test devices
| |||||||||||||||||
| CdEntityExtMemUtilUsed | 1.3.6.1.4.1.171.11.165.1000.5.1.4.1.4 | Unsigned32 | RO | 122324 | |||||||||||||
column · Unsigned32 · read-only · current This object indicates the used memory size of the entry.
Example values from LibreNMS test devices
| |||||||||||||||||
| CdEntityExtMemUtilFree | 1.3.6.1.4.1.171.11.165.1000.5.1.4.1.5 | Unsigned32 | RO | 120944 | |||||||||||||
column · Unsigned32 · read-only · current This object indicates the free memory size of the entry.
Example values from LibreNMS test devices
| |||||||||||||||||
| TdEntityExtCpuUtilTable | 1.3.6.1.4.1.171.11.165.1000.5.1.7 | NA | |||||||||||||||
table · not-accessible · current The table is used to display CPU utilization information. | |||||||||||||||||
| RdEntityExtCpuUtilEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.7.1 | NA | |||||||||||||||
row · not-accessible · current An entry contains CPU information. | |||||||||||||||||
| CdEntityExtCpuUtilUnitId | 1.3.6.1.4.1.171.11.165.1000.5.1.7.1.1 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID. | |||||||||||||||||
| CdEntityExtCpuUtilCpuID | 1.3.6.1.4.1.171.11.165.1000.5.1.7.1.2 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object is used to uniquely identify the CPU within a unit (multiprocessing system). | |||||||||||||||||
| CdEntityExtCpuUtilFiveSeconds | 1.3.6.1.4.1.171.11.165.1000.5.1.7.1.3 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current This objects indicates the overall CPU busy percentage in the last 5 second period. The value will be between 0% (idle) and 100% (very busy).
| |||||||||||||||||
| CdEntityExtCpuUtilOneMinute | 1.3.6.1.4.1.171.11.165.1000.5.1.7.1.4 | Unsigned32 | RO | ||||||||||||||
column · Unsigned32 · read-only · current This objects indicates the overall CPU busy percentage in the last 1 minute period. The value will be between 0% (idle) and 100% (very busy).
| |||||||||||||||||
| CdEntityExtCpuUtilFiveMinutes | 1.3.6.1.4.1.171.11.165.1000.5.1.7.1.5 | Unsigned32 | RO | 22 | |||||||||||||
column · Unsigned32 · read-only · current This objects indicates the overall CPU busy percentage in the last 5 minute period. The value will be between 0% (idle) and 100% (very busy). Example values from LibreNMS test devices
| |||||||||||||||||
| TdEntityExtVersionTable | 1.3.6.1.4.1.171.11.165.1000.5.1.8 | NA | |||||||||||||||
table · not-accessible · current The table is used to display version information of units. | |||||||||||||||||
| RdEntityExtVersionEntry | 1.3.6.1.4.1.171.11.165.1000.5.1.8.1 | NA | |||||||||||||||
row · not-accessible · current An entry contains version information of a unit. | |||||||||||||||||
| CdEntityExtVersionUnitId | 1.3.6.1.4.1.171.11.165.1000.5.1.8.1.1 | Unsigned32 (1..65535) | NA | ||||||||||||||
column · Unsigned32 (1..65535) · not-accessible · current This object indicates the unit (stacking device) or slot (chassis device) ID. | |||||||||||||||||
| CdEntityExtVersionRuntime | 1.3.6.1.4.1.171.11.165.1000.5.1.8.1.3 | DisplayString (SIZE (0..32)) | RO | 2.04.B012 | |||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This object indicates the firmware version of one unit. Example values from LibreNMS test devices
| |||||||||||||||||
| NdEntityExtConformance | 1.3.6.1.4.1.171.11.165.1000.5.2 | ||||||||||||||||
| NdEntityExtMIBCompliances | 1.3.6.1.4.1.171.11.165.1000.5.2.1 | ||||||||||||||||
| MdEntityExtCompliance | 1.3.6.1.4.1.171.11.165.1000.5.2.1.1 | ||||||||||||||||
compliance · current The compliance statement for entities which implement the DLINKSW-ENTITY-EXT-MIB. | |||||||||||||||||
| NdEntityExtMIBGroups | 1.3.6.1.4.1.171.11.165.1000.5.2.2 | ||||||||||||||||
| GdEntityExtTempGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.1 | ||||||||||||||||
group · current A collection of objects provides information of the system temperature. | |||||||||||||||||
| GdEntityExtFanGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.2 | ||||||||||||||||
group · current A collection of objects providing informations of fans. | |||||||||||||||||
| GdEntityExtPowerGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.3 | ||||||||||||||||
group · current A collection of objects providing information of power modules. | |||||||||||||||||
| GdEntityExtSystemInfoGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.4 | ||||||||||||||||
group · current A collection of objects provides information of the system temperature. | |||||||||||||||||
| GdEntityExtGenericNotifInfoGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.5 | ||||||||||||||||
group · current A collection of objects provides generic information for binding variables of notification.
| |||||||||||||||||
| GdEntityExtFanNotifGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.6 | ||||||||||||||||
group · current A collection of notifications for indicating the status change of fans.
| |||||||||||||||||
| GdEntityExtThermalNotifGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.7 | ||||||||||||||||
group · current A collection of notifications for indicating the status change of thermals.
| |||||||||||||||||
| GdEntityExtPowerNotifGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.8 | ||||||||||||||||
group · current A collection of notifications for indicating the status change of power module.
| |||||||||||||||||
| GdEntityExtAirFlowNotifGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.9 | ||||||||||||||||
group · current A collection of notifications for indicating the status change of the air flow.
| |||||||||||||||||
| GdEntityExtFactoryResetButtonNotifGroup | 1.3.6.1.4.1.171.11.165.1000.5.2.2.10 | ||||||||||||||||
group · current A collection of notifications for indicating the factory reset button.
| |||||||||||||||||
Traps / Notifications
- dEntityExtAirFlowChg
1.3.6.1.4.1.171.11.165.1000.5.0.4 - dEntityExtFactoryResetButton
1.3.6.1.4.1.171.11.165.1000.5.0.5 - dEntityExtFanStatusChg
1.3.6.1.4.1.171.11.165.1000.5.0.1 - dEntityExtPowerStatusChg
1.3.6.1.4.1.171.11.165.1000.5.0.3 - dEntityExtThermalStatusChg
1.3.6.1.4.1.171.11.165.1000.5.0.2