MIB Browser

DLINKSW-SFLOW-MIB

D-Link Systems, Inc.
The structure of sFlow for the proprietary enterprise.
Organization
D-Link Corp.
Root OID
1.3.6.1.4.1.171.14.36
Last updated
Objects
41
Source
Show full MIB
snmptranslate -m DLINKSW-SFLOW-MIB -Tp
snmpwalk -v2c -c <community> -m DLINKSW-SFLOW-MIB <host> 1.3.6.1.4.1.171.14.36

Imports

DLINK-ID-REC-MIBdlinkIndustrialCommon
INET-ADDRESS-MIBInetAddress, InetAddressIPv4, InetAddressIPv6, InetAddressType
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, RowStatus, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatus
IdlinkSwSFlowMIB1.3.6.1.4.1.171.14.36
NdSFlowMIBNotifications1.3.6.1.4.1.171.14.36.0
NdSFlowMIBObjects1.3.6.1.4.1.171.14.36.1
SdSFlowVersion1.3.6.1.4.1.171.14.36.1.1SnmpAdminStringRO
SdSFlowAgentAddressIPv41.3.6.1.4.1.171.14.36.1.2InetAddressIPv4RO
SdSFlowAgentAddressIPv61.3.6.1.4.1.171.14.36.1.3InetAddressIPv6RO
TdSFlowRcvrTable1.3.6.1.4.1.171.14.36.1.4NA
RdSFlowRcvrEntry1.3.6.1.4.1.171.14.36.1.4.1NA
CdSFlowRcvrIndex1.3.6.1.4.1.171.14.36.1.4.1.1Integer32 (1..65535)NA
CdSFlowRcvrOwner1.3.6.1.4.1.171.14.36.1.4.1.2DisplayString (SIZE (0..32))RW
CdSFlowRcvrAdminTimeout1.3.6.1.4.1.171.14.36.1.4.1.3Integer32 (0..2000000)RW
CdSFlowRcvrCurrentTimeout1.3.6.1.4.1.171.14.36.1.4.1.4Integer32RO
CdSFlowRcvrMaximumDatagramSize1.3.6.1.4.1.171.14.36.1.4.1.5Integer32 (700..1400)RW
CdSFlowRcvrAddressType1.3.6.1.4.1.171.14.36.1.4.1.6InetAddressTypeRW
CdSFlowRcvrAddress1.3.6.1.4.1.171.14.36.1.4.1.7InetAddressRW
CdSFlowRcvrVrfName1.3.6.1.4.1.171.14.36.1.4.1.8DisplayStringRW
CdSFlowRcvrPort1.3.6.1.4.1.171.14.36.1.4.1.9Integer32 (1..65535)RW
CdSFlowRcvrDatagramVersion1.3.6.1.4.1.171.14.36.1.4.1.10Integer32RO
CdSFlowRcvrReset1.3.6.1.4.1.171.14.36.1.4.1.11INTEGERRW
TdSFlowFsTable1.3.6.1.4.1.171.14.36.1.5NA
RdSFlowFsEntry1.3.6.1.4.1.171.14.36.1.5.1NA
CdSFlowFsDataSource1.3.6.1.4.1.171.14.36.1.5.1.1DSFlowDataSourceNA
CdSFlowFsInstance1.3.6.1.4.1.171.14.36.1.5.1.2DSFlowInstanceNA
CdSFlowFsReceiver1.3.6.1.4.1.171.14.36.1.5.1.3DSFlowReceiverRC
CdSFlowFsDirection1.3.6.1.4.1.171.14.36.1.5.1.4INTEGERRC
CdSFlowFsAdminSamplingRate1.3.6.1.4.1.171.14.36.1.5.1.5Integer32 (0..65536)RC
CdSFlowFsActiveSamplingRate1.3.6.1.4.1.171.14.36.1.5.1.6Integer32RO
CdSFlowFsMaximumHeaderSize1.3.6.1.4.1.171.14.36.1.5.1.7Integer32 (18..256)RC
CdSFlowFsRowStatus1.3.6.1.4.1.171.14.36.1.5.1.8RowStatusRC
TdSFlowCpTable1.3.6.1.4.1.171.14.36.1.6NA
RdSFlowCpEntry1.3.6.1.4.1.171.14.36.1.6.1NA
CdSFlowCpDataSource1.3.6.1.4.1.171.14.36.1.6.1.1DSFlowDataSourceNA
CdSFlowCpInstance1.3.6.1.4.1.171.14.36.1.6.1.2DSFlowInstanceNA
CdSFlowCpReceiver1.3.6.1.4.1.171.14.36.1.6.1.3DSFlowReceiverRC
CdSFlowCpInterval1.3.6.1.4.1.171.14.36.1.6.1.4Integer32 (0..120)RC
CdSFlowCpRowStatus1.3.6.1.4.1.171.14.36.1.6.1.5RowStatusRC
NdSFlowMIBConformance1.3.6.1.4.1.171.14.36.2
NdSFlowMIBCompliances1.3.6.1.4.1.171.14.36.2.1
MdSFlowCompliance1.3.6.1.4.1.171.14.36.2.1.1
NdSFlowMIBGroups1.3.6.1.4.1.171.14.36.2.2
GdSFlowAgentGroup1.3.6.1.4.1.171.14.36.2.2.1

Textual conventions

DSFlowDataSource Integer32 (1..2147483647)
Identifies the ifIndex of interface as the source of sFlow data.

DSFlowDataSources of this traditional form are called
'port-based'. Ideally the sampling entity will perform
sampling on all flows originating from or destined to
the specified interface. However, if the switch architecture
only allows input or output sampling then the sampling agent
is permitted to only sample input flows input or output flows.
Each packet must only be considered once for sampling,
irrespective of the number of ports it will be forwarded to.

Note: Since each DSFlowDataSource operates independently a
      packet that crosses multiple DataSources may generate
      multiple flow records.
DSFlowInstance Integer32 (1..65535)
If more than one sFlow sampler is available for this
DSFlowDataSource then individual samplers are distinguished
using the DSFlowInstance variable. The value of
DSFlowInstance ranges from 1..n where n is the number of
samplers associated with this DSFlowDataSource.

Note: Each sFlow sampler instance must operate
      independently of all other instances. Setting
      an attribute of one sampler must not alter the
      the behavior and settings of other sampler
       instances.
DSFlowReceiver Integer32
Identify the sFlow receiver associated with this resource.

A value of zero indicates that this resource is available.
If non-zero the value must correspond to a valid, active
dSFlowRcvrIndex.

If the value is currently zero it may be set to any
active entry in the dSFlowRcvrTable. If the value is
not zero then a set to anything other than zero or
its current value will result in an SNMP error (bad value).

Setting to zero frees the resource and returns all the
values in this entry to their default values.

If an entry in the dSFlowRcvrTable expires, either
because the dSFlowRcvrOwner is set to the empty
string or because the dSFlowRcvrCurrentTimeout reaches zero, then
the agent must mark all associated resources as available
(by setting the associated DSFlowReceiver entry to zero)
and all values in these records must be restored to their
default values.

This mechanism provides no enforcement and relies on the
cooperation of management entities in order to ensure that
competition for a resource is fairly resolved. A management
entity should not make any changes to a resource
without first acquiring it by successfully writing its
dSFlowRcvrIndex value as the DSFlowReceiver for the resource.