AGENT-GENERAL-MIB
D-Link Systems, Inc.The structure of general management information for enterprise.
snmptranslate -m AGENT-GENERAL-MIB -Tpsnmpwalk -v2c -c <community> -m AGENT-GENERAL-MIB <host> 1.3.6.1.4.1.171.12.1Imports
| DLINK-ID-REC-MIB | AgentNotifyLevel, dlink-common-mgmt |
|---|---|
| INET-ADDRESS-MIB | InetAddress, InetAddressType |
| Q-BRIDGE-MIB | VlanId |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IagentGeneralMgmt | 1.3.6.1.4.1.171.12.1 | ||||||||||||||||||||
identity The structure of general management information for enterprise. | |||||||||||||||||||||
| NagentBasicInfo | 1.3.6.1.4.1.171.12.1.1 | ||||||||||||||||||||
| SagentMgmtProtocolCapability | 1.3.6.1.4.1.171.12.1.1.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The network management protocol(s) supported by this agent.
| |||||||||||||||||||||
| TagentMibCapabilityTable | 1.3.6.1.4.1.171.12.1.1.2 | NA | |||||||||||||||||||
table · not-accessible · current A list of MIB capability entries supported by this agent. | |||||||||||||||||||||
| RagentMibCapabilityEntry | 1.3.6.1.4.1.171.12.1.1.2.1 | NA | |||||||||||||||||||
row · not-accessible · current A MIB capability entry containing objects that describe a particular MIB supported by this agent. | |||||||||||||||||||||
| CagentMibCapabilityIndex | 1.3.6.1.4.1.171.12.1.1.2.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current A list of Agent MIB Capability Description entries. | |||||||||||||||||||||
| CagentMibCapabilityDescr | 1.3.6.1.4.1.171.12.1.1.2.1.2 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current The name of the MIB supported by the agent. | |||||||||||||||||||||
| CagentMibCapabilityVersion | 1.3.6.1.4.1.171.12.1.1.2.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The version of the MIB specified in this entry. | |||||||||||||||||||||
| CagentMibCapabilityType | 1.3.6.1.4.1.171.12.1.1.2.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The type of MIB specified in this entry.
| |||||||||||||||||||||
| SagentStatusConsoleInUse | 1.3.6.1.4.1.171.12.1.1.3 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This indicates whether the console is currently in use.
| |||||||||||||||||||||
| SagentStatusSaveCfg | 1.3.6.1.4.1.171.12.1.1.4 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This indicates the status of the device configuration.
other (1) - This entry is currently in use but the conditions under
which it will remain so are determined by each of the following values.
proceeding (2) - The device configuration is currently being saved into NV-RAM.
completed (3) - All of the device configuration parameters have been
saved into NV-RAM.
failed (4) - The process to save the device configuration has failed.
| |||||||||||||||||||||
| SagentStatusFileTransfer | 1.3.6.1.4.1.171.12.1.1.5 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The status of the firmware download control. If the value is stated as 'other', the firmware has not been updated since the device was started.
| |||||||||||||||||||||
| NagentCPUutilization | 1.3.6.1.4.1.171.12.1.1.6 | ||||||||||||||||||||
| SagentCPUutilizationIn5sec | 1.3.6.1.4.1.171.12.1.1.6.1 | Integer32 | RO | 24 | |||||||||||||||||
scalar · Integer32 · read-only · current The time scale is set at 5 second intervals. The value will be between 0% (idle) and 100% (very busy). Example values from LibreNMS test devices
| |||||||||||||||||||||
| SagentCPUutilizationIn1min | 1.3.6.1.4.1.171.12.1.1.6.2 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The time scale is set at 1 minute intervals. The value will be between 0% (idle) and 100% (very busy). | |||||||||||||||||||||
| SagentCPUutilizationIn5min | 1.3.6.1.4.1.171.12.1.1.6.3 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The time scale is set at 5 minute intervals. The value will be between 0% (idle) and 100% (very busy). | |||||||||||||||||||||
| SagentDualImageStatus | 1.3.6.1.4.1.171.12.1.1.7 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The dual image status.
| |||||||||||||||||||||
| TagentPORTutilizationTable | 1.3.6.1.4.1.171.12.1.1.8 | NA | |||||||||||||||||||
table · not-accessible · current This table specifies the current utilization of a specified port. | |||||||||||||||||||||
| RagentPORTutilizationEntry | 1.3.6.1.4.1.171.12.1.1.8.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information regarding the port utilization function. | |||||||||||||||||||||
| CagentPORTutilizationProtIndex | 1.3.6.1.4.1.171.12.1.1.8.1.1 | INTEGER (1..65535) | RO | ||||||||||||||||||
column · INTEGER (1..65535) · read-only · current This object indicates the module's port number. | |||||||||||||||||||||
| CagentPORTutilizationTX | 1.3.6.1.4.1.171.12.1.1.8.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current rate of transmitted frames on the specified port. | |||||||||||||||||||||
| CagentPORTutilizationRX | 1.3.6.1.4.1.171.12.1.1.8.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current rate of received frames on the specified port. | |||||||||||||||||||||
| CagentPORTutilizationUtil | 1.3.6.1.4.1.171.12.1.1.8.1.4 | INTEGER (0..100) | RO | ||||||||||||||||||
column · INTEGER (0..100) · read-only · current The current percentages regarding port statistics.
| |||||||||||||||||||||
| CagentPORTutilizationRXUtil | 1.3.6.1.4.1.171.12.1.1.8.1.5 | INTEGER (0..100) | RO | ||||||||||||||||||
column · INTEGER (0..100) · read-only · current The current percentages regarding port receive packets statistics.
| |||||||||||||||||||||
| CagentPORTutilizationTXUtil | 1.3.6.1.4.1.171.12.1.1.8.1.6 | INTEGER (0..100) | RO | ||||||||||||||||||
column · INTEGER (0..100) · read-only · current The current percentages regarding port transmit packets statistics.
| |||||||||||||||||||||
| TagentDRAMutilizationTable | 1.3.6.1.4.1.171.12.1.1.9 | NA | |||||||||||||||||||
table · not-accessible · current Information about DRAM memory. | |||||||||||||||||||||
| RagentDRAMutilizationEntry | 1.3.6.1.4.1.171.12.1.1.9.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information about DRAM memory. | |||||||||||||||||||||
| CagentDRAMutilizationUnitID | 1.3.6.1.4.1.171.12.1.1.9.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies the unit ID. If the ID equals zero, it means the current device. | |||||||||||||||||||||
| CagentDRAMutilizationTotalDRAM | 1.3.6.1.4.1.171.12.1.1.9.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The size of total DRAM memory.
| |||||||||||||||||||||
| CagentDRAMutilizationUsedDRAM | 1.3.6.1.4.1.171.12.1.1.9.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The size of used DRAM memory.
| |||||||||||||||||||||
| CagentDRAMutilization | 1.3.6.1.4.1.171.12.1.1.9.1.4 | INTEGER | RO | 59 | |||||||||||||||||
column · INTEGER · read-only · current The percentage of used DRAM memory of the total DRAM memory available. The value will be between 0% (idle) and 100% (very busy). Example values from LibreNMS test devices
| |||||||||||||||||||||
| TagentFLASHutilizationTable | 1.3.6.1.4.1.171.12.1.1.10 | NA | |||||||||||||||||||
table · not-accessible · current Information about the flash memory. | |||||||||||||||||||||
| RagentFLASHutilizationEntry | 1.3.6.1.4.1.171.12.1.1.10.1 | NA | |||||||||||||||||||
| CagentFLASHutilizationUnitID | 1.3.6.1.4.1.171.12.1.1.10.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies the unit ID. If the ID equals zero, it means the current device. | |||||||||||||||||||||
| CagentFLASHutilizationTotalFLASH | 1.3.6.1.4.1.171.12.1.1.10.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The total size of flash memory.
| |||||||||||||||||||||
| CagentFLASHutilizationUsedFLASH | 1.3.6.1.4.1.171.12.1.1.10.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The size of the used flash memory.
| |||||||||||||||||||||
| CagentFLASHutilization | 1.3.6.1.4.1.171.12.1.1.10.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The percentage of used flash memory in total flash memory. The value will be between 0% (idle) and 100% (very busy). | |||||||||||||||||||||
| SagentStatusReset | 1.3.6.1.4.1.171.12.1.1.11 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This indicates the status of 'agentReset'.
| |||||||||||||||||||||
| SagentSerialNumber | 1.3.6.1.4.1.171.12.1.1.12 | DisplayString | RO | | |||||||||||||||||
scalar · DisplayString · read-only · current A text string containing the serial number of this device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SagentFirmwareType | 1.3.6.1.4.1.171.12.1.1.13 | DisplayString | RO | ||||||||||||||||||
scalar · DisplayString · read-only · current A text string containing the firmware type. | |||||||||||||||||||||
| NagentBasicConfig | 1.3.6.1.4.1.171.12.1.2 | ||||||||||||||||||||
| TagentBscSwFileTable | 1.3.6.1.4.1.171.12.1.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A list of MIB Basic Config entry support files updated by this agent. | |||||||||||||||||||||
| RagentBscSwFileEntry | 1.3.6.1.4.1.171.12.1.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current A basic configuration entry containing the objects that describe a particular MIB supported by this agent.
| |||||||||||||||||||||
| CagentBscSwFileIndex | 1.3.6.1.4.1.171.12.1.2.1.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The table index for the file entry | |||||||||||||||||||||
| CagentBscSwFileDscr | 1.3.6.1.4.1.171.12.1.2.1.1.2 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current The description of the software file purpose in this entry. Note: For systems that do not support a change to this object, setting a value for this object will cause the system to return bad-value error messages. | |||||||||||||||||||||
| CagentBscSwFileAddr | 1.3.6.1.4.1.171.12.1.2.1.1.3 | IpAddress | RW | ||||||||||||||||||
column · IpAddress · read-write · current The IP address where the file that needs to be downloaded is located, or the IP address where the file will be uploaded to. | |||||||||||||||||||||
| CagentBscSwFileTransferType | 1.3.6.1.4.1.171.12.1.2.1.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current The channel through which the file will be downloaded or uploaded. Note: For systems that do not support all channels, setting a value to the unsupported channel will cause the system to return bad-value error messages.
| |||||||||||||||||||||
| CagentBscSwFile | 1.3.6.1.4.1.171.12.1.2.1.1.5 | DisplayString (SIZE (0..128)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..128)) · read-write · current The name of the file to be downloaded from, or uploaded to, the TFTP server. | |||||||||||||||||||||
| CagentBscSwFileLocateId | 1.3.6.1.4.1.171.12.1.2.1.1.6 | INTEGER (1..16) | RW | ||||||||||||||||||
column · INTEGER (1..16) · read-write · current This object describes the type of file. runtime-code (1), log-file (2), cfg-file (3) Note: For systems that do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages. | |||||||||||||||||||||
| CagentBscSwFileLoadType | 1.3.6.1.4.1.171.12.1.2.1.1.7 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object provides the user with a choice of uploading or downloading the selected file. Note: For systems that do not support a change to this object, setting a value for this object will cause the system to return bad-value error messages.
| |||||||||||||||||||||
| CagentBscSwFileCtrl | 1.3.6.1.4.1.171.12.1.2.1.1.8 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object gives the user the option of downloading runtime software. This setting will take effect
when the system restarts. See Note (1) below
Note:
For systems that do not support changes to this object, setting a value to this object
will cause the system to return bad-value error messages.
start - Activate firmware.
delete (4) - Delete the firmware by indicated firmware ID.
config-as-bootup (5) - Configured as bootup firmware by the indicated
firmware(ID).
apply (6) - Apply the configuration to be the active configuration by the indicated config ID.
| |||||||||||||||||||||
| CagentBscSwFileBIncrement | 1.3.6.1.4.1.171.12.1.2.1.1.9 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current This object indicates whether the previous configuration will remain valid or not after downloading the configuration file. True: Keep valid False: Erase. | |||||||||||||||||||||
| CagentBscSwFileCtrlID | 1.3.6.1.4.1.171.12.1.2.1.1.10 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current The section ID of the firmware image or configuration file. A value of 0 indicates the boot-up firmware image or configuration file. | |||||||||||||||||||||
| CagentBscSwFileCtrlUnitID | 1.3.6.1.4.1.171.12.1.2.1.1.11 | UnitList | RW | ||||||||||||||||||
column · UnitList · read-write · current Specifies which unit of the switch stack the firmware image will be downloaded from. One or more units can be set in this list. Each bit from the left to the right represents the switch from unit ID 1 to unit ID 12. A null entry in this field denotes all switches in the switch stack. | |||||||||||||||||||||
| CagentBscSwFileIPv6Addr | 1.3.6.1.4.1.171.12.1.2.1.1.12 | Ipv6Address | RW | ||||||||||||||||||
column · Ipv6Address · read-write · current The IPv6 address where the file will be downloaded from or uploaded to. | |||||||||||||||||||||
| CagentBscSwFileBootUpImage | 1.3.6.1.4.1.171.12.1.2.1.1.13 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current The result of the download will depend on whether the boot_up option is specified. Case 1: In the case where the master unit provides the file system and the slave unit does not provide the file system, when boot_up is specified, the file will be downloaded to the boot_up image on the slave. If boot_up is not specified, then the file will not be downloaded to this slave unit. Case 2: In the case where the master unit does not provide the file system and the slave unit provides the file system, when boot_up is specified, the file will be downloaded to the boot_up image on the slave unit. If boot_up is not specified, the file will not be downloaded to this slave unit. Case 3: In the case where the master unit and the slave unit both support or do not support the file system, the file will be downloaded to the specified file on the slave unit. If boot_up is specified, the downloaded file will be assigned as the boot_up image. True: boot_up option is specified. False: boot_up option is not specified. | |||||||||||||||||||||
| CagentBscSwFileForceAgree | 1.3.6.1.4.1.171.12.1.2.1.1.14 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current When the force_agree option is specified, the reboot command will be executed immediately, without any further confirmation from the user. True: force_agree option is specified. False: force_agree option is not specified. | |||||||||||||||||||||
| CagentBscSwFileInterfaceName | 1.3.6.1.4.1.171.12.1.2.1.1.15 | DisplayString (SIZE (0..12)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-write · current This node is used to specify the interface name when the agentBscSwFileIPv6Addr is the link local address. | |||||||||||||||||||||
| CagentBscSwFileServerDomainName | 1.3.6.1.4.1.171.12.1.2.1.1.16 | DisplayString (SIZE (0..255)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-write · current This object indicates the domain name of the TFTP server. | |||||||||||||||||||||
| SagentFileTransfer | 1.3.6.1.4.1.171.12.1.2.2 | INTEGER | RW | obsolete | |||||||||||||||||
scalar · INTEGER · read-write · obsolete This object will execute the download or upload action. If start (2) is chosen, it will begin to download/upload and no reset will follow. If start-and-reset (3) is chosen, then the reset will be activated after completing the download or upload. No action if noaction (4) is chosen. Note: Because these functions will be limited by the support for the system in question, some of the selected items will be invalid. When the user selects an invalid entry, the system will respond with a bad-value status.
| |||||||||||||||||||||
| SagentSystemReset | 1.3.6.1.4.1.171.12.1.2.3 | INTEGER | RW | deprecated | |||||||||||||||||
scalar · INTEGER · read-write · deprecated This object indicates the agent system reset state. Setting this
object to no-reset (4) has no effect. Setting this object to
cold-start (2) or warm-start (3) will reset the agent. The agent
always returns to no-reset (4) when this object is read.
This object is replaced by 'agentReset'.
| |||||||||||||||||||||
| SagentRs232PortConfig | 1.3.6.1.4.1.171.12.1.2.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates the RS-232C mode once the device has restarted.
| |||||||||||||||||||||
| SagentOutOfBandBaudRateConfig | 1.3.6.1.4.1.171.12.1.2.5 | INTEGER | RW | obsolete | |||||||||||||||||
scalar · INTEGER · read-write · obsolete This object allows the user to specify an out-of-band baud rate, which
will take effect upon system restart.
Note:
Because these functions will be limited by the support for the system
in question, some of the selected items will be invalid. When the user
selects an invalid entry, the system will respond with a bad-value error message.
| |||||||||||||||||||||
| SagentSaveCfg | 1.3.6.1.4.1.171.12.1.2.6 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates the type of save command to be executed, when saving to NV-RAM. other (1) - None of the following. cfg-id1 (2) - Save configuration ID1. cfg-id2 (3)- Save configuration ID2. log (4) - Save log. all (5) - Save both (active configuration and log).
| |||||||||||||||||||||
| TswMultiImageInfoTable | 1.3.6.1.4.1.171.12.1.2.7 | NA | |||||||||||||||||||
| RswMultiImageInfoEntry | 1.3.6.1.4.1.171.12.1.2.7.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information about multiple image management.
| |||||||||||||||||||||
| CswMultiImageInfoID | 1.3.6.1.4.1.171.12.1.2.7.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The stacking section ID of the firmware image. The stacking section ID = 256 * Unit ID + Image File ID. | |||||||||||||||||||||
| CswMultiImageVersion | 1.3.6.1.4.1.171.12.1.2.7.1.2 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current The recorded downloaded firmware version. | |||||||||||||||||||||
| CswMultiImageSize | 1.3.6.1.4.1.171.12.1.2.7.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The recorded downloaded firmware size. | |||||||||||||||||||||
| CswMultiImageUpdateTime | 1.3.6.1.4.1.171.12.1.2.7.1.4 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current The recorded firmware update time. | |||||||||||||||||||||
| CswMultiImageFrom | 1.3.6.1.4.1.171.12.1.2.7.1.5 | DisplayString (SIZE (0..100)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..100)) · read-only · current The recorded IP address of the TFTP server | |||||||||||||||||||||
| CswMultiImageSendUser | 1.3.6.1.4.1.171.12.1.2.7.1.6 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current The record of the user who downloaded the firmware. | |||||||||||||||||||||
| CswMultiImageFileName | 1.3.6.1.4.1.171.12.1.2.7.1.7 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current When the system is set to boot from SD card, this object will display the recorded path name of the boot firmware file. | |||||||||||||||||||||
| NagentMultiCfgMgmt | 1.3.6.1.4.1.171.12.1.2.8 | ||||||||||||||||||||
| TswMultiCfgInfoTable | 1.3.6.1.4.1.171.12.1.2.8.1 | NA | |||||||||||||||||||
| RswMultiCfgInfoEntry | 1.3.6.1.4.1.171.12.1.2.8.1.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information about multiple configuration files.
| |||||||||||||||||||||
| CswMultiCfgInfoID | 1.3.6.1.4.1.171.12.1.2.8.1.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The section ID of the configuration files. | |||||||||||||||||||||
| CswMultiCfgVersion | 1.3.6.1.4.1.171.12.1.2.8.1.1.2 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current The recorded downloaded configuration version. | |||||||||||||||||||||
| CswMultiCfgSize | 1.3.6.1.4.1.171.12.1.2.8.1.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The recorded downloaded configuration size (in bytes). | |||||||||||||||||||||
| CswMultiCFgUpdateTime | 1.3.6.1.4.1.171.12.1.2.8.1.1.4 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current The recorded configuration update time displayed in string format, i.e. yyyy/mon/dd hh:mm:ss. | |||||||||||||||||||||
| CswMultiCfgFrom | 1.3.6.1.4.1.171.12.1.2.8.1.1.5 | DisplayString (SIZE (0..100)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..100)) · read-only · current The recorded IP address of the TFTP server. | |||||||||||||||||||||
| CswMultiCfgSendUser | 1.3.6.1.4.1.171.12.1.2.8.1.1.6 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current The record of the user who downloaded the configuration file | |||||||||||||||||||||
| CswMultiCfgFileName | 1.3.6.1.4.1.171.12.1.2.8.1.1.7 | DisplayString (SIZE (0..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-only · current When the system is set to boot from SD card, this object displays the recorded path name of the boot configuration file. | |||||||||||||||||||||
| SswMultiCfgCurrentUsed | 1.3.6.1.4.1.171.12.1.2.8.2 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The indicated configuration file ID of the system currently in use. | |||||||||||||||||||||
| SswMultiCfgBootUp | 1.3.6.1.4.1.171.12.1.2.8.3 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This object indicates the configuration file ID which will take effect upon the next reboot. | |||||||||||||||||||||
| TswMultiCfgCtrlTable | 1.3.6.1.4.1.171.12.1.2.8.4 | NA | |||||||||||||||||||
| RswMultiCfgCtrlEntry | 1.3.6.1.4.1.171.12.1.2.8.4.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information about multiple configuration management.
| |||||||||||||||||||||
| CswMultiCfgCtrlID | 1.3.6.1.4.1.171.12.1.2.8.4.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The section ID of the configuration file.
| |||||||||||||||||||||
| CswMultiCfgAction | 1.3.6.1.4.1.171.12.1.2.8.4.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current save: Save configuration to active configuration ID when the parameter is omitted.
active: Set any valid configuration as the active configuration.
delete: Removes the configuration from the flash memory. This configuration
cannot be the active or current configuration file.
apply: Loads the indicated configuration file and applies it to the system.
config-as-bootup-cfg: Configured as the boot-up configuration by the indicated configuration(ID).
| |||||||||||||||||||||
| NsystemSeverityControlMgmt | 1.3.6.1.4.1.171.12.1.2.9 | ||||||||||||||||||||
| SsystemSeverityTrapControl | 1.3.6.1.4.1.171.12.1.2.9.1 | AgentNotifyLevel | RW | ||||||||||||||||||
scalar · AgentNotifyLevel · read-write · current Indicates the level of trap severity control. The system has a severity level control and each trap should have a severity control set. When trap events occur and its severity is higher than the system severity control level, the trap works as defined. If the event severity is lower than the system severity control level, the event is ignored as if it did not occur. | |||||||||||||||||||||
| SsystemSeverityLogControl | 1.3.6.1.4.1.171.12.1.2.9.2 | AgentNotifyLevel | RW | ||||||||||||||||||
scalar · AgentNotifyLevel · read-write · current Indicates the level of trap severity control. The system has a severity level control and each trap should have a severity control set. When trap events occur and its severity is higher than the system severity control level, the trap works as defined. If the event severity is lower than the system severity control level, the event is ignored as if it did not occur. | |||||||||||||||||||||
| NagentTrustedHostMgmt | 1.3.6.1.4.1.171.12.1.2.10 | ||||||||||||||||||||
| TagentTrustedHostTable | 1.3.6.1.4.1.171.12.1.2.10.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains the trusted host information. | |||||||||||||||||||||
| RagentTrustedHostEntry | 1.3.6.1.4.1.171.12.1.2.10.1.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information about the trusted hosts. | |||||||||||||||||||||
| CagentTrustedHostIndex | 1.3.6.1.4.1.171.12.1.2.10.1.1.1 | INTEGER (1..30) | RO | ||||||||||||||||||
column · INTEGER (1..30) · read-only · current The index of the trusted host entry. | |||||||||||||||||||||
| CagentTrustedHostIPAddress | 1.3.6.1.4.1.171.12.1.2.10.1.1.2 | IpAddress | RC | ||||||||||||||||||
column · IpAddress · read-create · current Specifies the IP address of the trusted host. | |||||||||||||||||||||
| CagentTrustedHostRowStatus | 1.3.6.1.4.1.171.12.1.2.10.1.1.3 | RowStatus | RC | ||||||||||||||||||
column · RowStatus · read-create · current Indicates the status of this entry. When creating a trusted host entry, the IP address should also be set. | |||||||||||||||||||||
| CagentTrustedHostIPSubnetMask | 1.3.6.1.4.1.171.12.1.2.10.1.1.4 | IpAddress | RC | ||||||||||||||||||
column · IpAddress · read-create · current Specifies the IP subnet mask of the trusted host. | |||||||||||||||||||||
| CagentTrustedHostForSNMP | 1.3.6.1.4.1.171.12.1.2.10.1.1.5 | INTEGER | RC | ||||||||||||||||||
column · INTEGER · read-create · current Specifies the trusted host for SNMP.
| |||||||||||||||||||||
| CagentTrustedHostForTELNET | 1.3.6.1.4.1.171.12.1.2.10.1.1.6 | INTEGER | RC | ||||||||||||||||||
column · INTEGER · read-create · current Specifies the trusted host for Telnet.
| |||||||||||||||||||||
| CagentTrustedHostForSSH | 1.3.6.1.4.1.171.12.1.2.10.1.1.7 | INTEGER | RC | ||||||||||||||||||
column · INTEGER · read-create · current Specifies the trusted host for SSH.
| |||||||||||||||||||||
| CagentTrustedHostForHTTP | 1.3.6.1.4.1.171.12.1.2.10.1.1.8 | INTEGER | RC | ||||||||||||||||||
column · INTEGER · read-create · current Specifies the trusted host for HTTP.
| |||||||||||||||||||||
| CagentTrustedHostForHTTPS | 1.3.6.1.4.1.171.12.1.2.10.1.1.9 | INTEGER | RC | ||||||||||||||||||
column · INTEGER · read-create · current Specifies the trusted host for HTTPS.
| |||||||||||||||||||||
| CagentTrustedHostForPING | 1.3.6.1.4.1.171.12.1.2.10.1.1.10 | INTEGER | RC | ||||||||||||||||||
column · INTEGER · read-create · current Specifies the trusted host for PING.
| |||||||||||||||||||||
| CagentTrustedHostAddrType | 1.3.6.1.4.1.171.12.1.2.10.1.1.11 | InetAddressType | RC | ||||||||||||||||||
column · InetAddressType · read-create · current The type of trusted host address as specified by the 'agentTrustedHostAddr' object. | |||||||||||||||||||||
| CagentTrustedHostAddr | 1.3.6.1.4.1.171.12.1.2.10.1.1.12 | InetAddress | RC | ||||||||||||||||||
column · InetAddress · read-create · current Specifies the IP address of the trusted host. | |||||||||||||||||||||
| CagentTrustedHostIPv6PrefixLen | 1.3.6.1.4.1.171.12.1.2.10.1.1.13 | INTEGER (1..128) | RC | ||||||||||||||||||
column · INTEGER (1..128) · read-create · current Specifies the IPv6 prefix length of the IPv6 trusted host. | |||||||||||||||||||||
| SagentTrustedHostDelAllState | 1.3.6.1.4.1.171.12.1.2.10.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Used to delete all trusted host entries.
| |||||||||||||||||||||
| NagentFDBMgmt | 1.3.6.1.4.1.171.12.1.2.11 | ||||||||||||||||||||
| SagentFDBClearAllState | 1.3.6.1.4.1.171.12.1.2.11.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Used to clear all FDB entries.
| |||||||||||||||||||||
| TagentFDBClearByPortTable | 1.3.6.1.4.1.171.12.1.2.11.2 | NA | |||||||||||||||||||
table · not-accessible · current Used to clear FDB entries by port. | |||||||||||||||||||||
| RagentFDBClearByPortEntry | 1.3.6.1.4.1.171.12.1.2.11.2.1 | NA | |||||||||||||||||||
row · not-accessible · current This is an entry of the agentFDBClearByPortTable. | |||||||||||||||||||||
| CagentFDBClearPortIndex | 1.3.6.1.4.1.171.12.1.2.11.2.1.1 | INTEGER (1..65535) | NA | ||||||||||||||||||
column · INTEGER (1..65535) · not-accessible · current This object indicates the port number. | |||||||||||||||||||||
| CagentFDBClearByPortAction | 1.3.6.1.4.1.171.12.1.2.11.2.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object indicates whether to clear FDB or not.
| |||||||||||||||||||||
| TagentFDBClearByVlanTable | 1.3.6.1.4.1.171.12.1.2.11.3 | NA | |||||||||||||||||||
table · not-accessible · current Used to clear FDB entries by port. | |||||||||||||||||||||
| RagentFDBClearByVlanEntry | 1.3.6.1.4.1.171.12.1.2.11.3.1 | NA | |||||||||||||||||||
| CagentFDBClearVid | 1.3.6.1.4.1.171.12.1.2.11.3.1.1 | VlanId | NA | ||||||||||||||||||
column · VlanId · not-accessible · current This object indicates the VLAN-ID. | |||||||||||||||||||||
| CagentFDBClearByVlanAction | 1.3.6.1.4.1.171.12.1.2.11.3.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object indicates whether to clear the FDB or not.
| |||||||||||||||||||||
| TagentFDBSecurityTable | 1.3.6.1.4.1.171.12.1.2.11.4 | NA | |||||||||||||||||||
table · not-accessible · current Used to display the FDB entries that have been created by the security module. | |||||||||||||||||||||
| RagentFDBSecurityEntry | 1.3.6.1.4.1.171.12.1.2.11.4.1 | NA | |||||||||||||||||||
row · not-accessible · current This is an entry of agentFDBSecurityTable. | |||||||||||||||||||||
| CagentFDBVid | 1.3.6.1.4.1.171.12.1.2.11.4.1.1 | VlanId | NA | ||||||||||||||||||
column · VlanId · not-accessible · current This object indicates the VLAN-ID. | |||||||||||||||||||||
| CagentFDBMacAddress | 1.3.6.1.4.1.171.12.1.2.11.4.1.2 | MacAddress | NA | ||||||||||||||||||
column · MacAddress · not-accessible · current This object indicates the MAC address. | |||||||||||||||||||||
| CagentFDBPort | 1.3.6.1.4.1.171.12.1.2.11.4.1.3 | INTEGER (1..65535) | RO | ||||||||||||||||||
column · INTEGER (1..65535) · read-only · current This object indicates the port number. | |||||||||||||||||||||
| CagentFDBType | 1.3.6.1.4.1.171.12.1.2.11.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object indicates the MAC address type.
| |||||||||||||||||||||
| CagentFDBStatus | 1.3.6.1.4.1.171.12.1.2.11.4.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object indicates the MAC address's forwarding status.
| |||||||||||||||||||||
| CagentFDBSecurityModule | 1.3.6.1.4.1.171.12.1.2.11.4.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This object is used to indicate which security module created the current MAC address. dot1x: 802.1X. wac: Web-based Access Control. jwac: Web-Based Access Control extension for Japan. port-security: Port Security. mac-based-access-control: MAC-based Access Control. compound-authentication: Compound Authentication.
| |||||||||||||||||||||
| NagentARPMgmt | 1.3.6.1.4.1.171.12.1.2.12 | ||||||||||||||||||||
| SagentARPClearAllState | 1.3.6.1.4.1.171.12.1.2.12.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Used to clear all ARP entries.
| |||||||||||||||||||||
| NagentGratuitousARPMgmt | 1.3.6.1.4.1.171.12.1.2.12.2 | ||||||||||||||||||||
| SagentGratuitousARPSendIpifStatusUpState | 1.3.6.1.4.1.171.12.1.2.12.2.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This is used to enable/disable sending of gratuitous ARP request packets while the IPIF interface comes up. This is used to automatically announce the interface's IP address to other nodes. By default, the state is enabled, and only one ARP packet will be broadcast.
| |||||||||||||||||||||
| SagentGratuitousARPSendDupIpDetectedState | 1.3.6.1.4.1.171.12.1.2.12.2.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This is used to enable/disable the sending of gratuitous ARP request packets while a duplicate IP is detected. By default, the state is enabled. The duplicate IP detected state indicates that the system has received an ARP request packet that was sent by an IP address that matches the system's own IP address. In this case, the system knows that somebody out there is using an IP address that is in conflict with the system. In order to reclaim the correct host of this IP address, the system can send out the gratuitous ARP request packet for this duplicate IP address.
| |||||||||||||||||||||
| SagentGratuitousARPLearningState | 1.3.6.1.4.1.171.12.1.2.12.2.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This is used to enable/disable learning of an ARP entry in the ARP cache based on the received gratuitous ARP packet. If the switch receives a gratuitous ARP request/reply packet and the sender's IP address is in its ARP table, it should update the ARP entry. By default, the state is disabled.
| |||||||||||||||||||||
| TagentGratuitousARPTable | 1.3.6.1.4.1.171.12.1.2.12.2.4 | NA | |||||||||||||||||||
table · not-accessible · current Gratuitous ARP Table Information. | |||||||||||||||||||||
| RagentGratuitousARPEntry | 1.3.6.1.4.1.171.12.1.2.12.2.4.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information from the Gratuitous ARP Table. | |||||||||||||||||||||
| CagentGratuitousARPInterfaceName | 1.3.6.1.4.1.171.12.1.2.12.2.4.1.1 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The name of the IP interface. | |||||||||||||||||||||
| CagentGratuitousARPPeriodicalSendInterval | 1.3.6.1.4.1.171.12.1.2.12.2.4.1.2 | INTEGER (0..65535) | RW | ||||||||||||||||||
column · INTEGER (0..65535) · read-write · current This is used to configure the interval for the periodic sending of gratuitous ARP request packets. 0 means do not send gratuitous ARP request packets periodically.
| |||||||||||||||||||||
| CagentGratuitousARPTrapState | 1.3.6.1.4.1.171.12.1.2.12.2.4.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This indicates the state of the gratuitous ARP trap. The switch can trap the IP conflict events to inform the administrator. By default, the trap is disabled.
| |||||||||||||||||||||
| CagentGratuitousARPLogState | 1.3.6.1.4.1.171.12.1.2.12.2.4.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This indicates the state of the gratuitous Log trap. The switch can log the IP conflict events to inform the administrator. By default, the event log is enabled.
| |||||||||||||||||||||
| SagentARPTotalARPEntries | 1.3.6.1.4.1.171.12.1.2.12.3 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Used to display the total number of ARP entries. | |||||||||||||||||||||
| SagentARPRetryTimes | 1.3.6.1.4.1.171.12.1.2.12.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This indicates the retry times of the ARP request. | |||||||||||||||||||||
| TswMultiImageCtrlTable | 1.3.6.1.4.1.171.12.1.2.13 | NA | |||||||||||||||||||
| RswMultiImageCtrlEntry | 1.3.6.1.4.1.171.12.1.2.13.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information about multiple image management.
| |||||||||||||||||||||
| CswMultiImageCtrlID | 1.3.6.1.4.1.171.12.1.2.13.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The stacking section ID of the firmware image. The stacking section ID = 256 * Unit ID + Image File ID. | |||||||||||||||||||||
| CswMultiImageCtrlAction | 1.3.6.1.4.1.171.12.1.2.13.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object indicates the running status of the image which is specified by swMultiImageCtrlID and swMultiImageCtrlUnitID. config-as-bootup-fw (1) - Configured as the bootup firmware by the indicated firmware(ID). delete (2) - Delete the firmware by indicated firmware ID. none (3) - No action.
| |||||||||||||||||||||
| SagentOutOfBandDataBits | 1.3.6.1.4.1.171.12.1.2.14 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This object indicates the out-of-band data bits. | |||||||||||||||||||||
| SagentOutOfBandParityBits | 1.3.6.1.4.1.171.12.1.2.15 | DisplayString | RO | ||||||||||||||||||
scalar · DisplayString · read-only · current This object indicates the out-of-band parity bits. | |||||||||||||||||||||
| SagentOutOfBandStopBits | 1.3.6.1.4.1.171.12.1.2.16 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current This object indicates the out-of-band stop bits. | |||||||||||||||||||||
| SagentOutOfBandAutoLogoutConfig | 1.3.6.1.4.1.171.12.1.2.17 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object allows the user to specify an out-of-band auto logout time.
| |||||||||||||||||||||
| NagentBscFileSystemMgmt | 1.3.6.1.4.1.171.12.1.2.18 | ||||||||||||||||||||
| TagentBscFileSystemTable | 1.3.6.1.4.1.171.12.1.2.18.1 | NA | |||||||||||||||||||
table · not-accessible · current A list of MIB File System Basic Configuration entries supported by the file update of this agent. | |||||||||||||||||||||
| RagentBscFileSystemEntry | 1.3.6.1.4.1.171.12.1.2.18.1.1 | NA | |||||||||||||||||||
row · not-accessible · current A File System basic configuration entry that contains objects describing a particular MIB supported by this agent. | |||||||||||||||||||||
| CagentBscFileSystemIndex | 1.3.6.1.4.1.171.12.1.2.18.1.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The table index for the file entry.
This object describes the file type.
runtime-code (1),
log-file (2),
cfg-file (3),
attack-log-file (7) | |||||||||||||||||||||
| CagentBscFileSystemDscr | 1.3.6.1.4.1.171.12.1.2.18.1.1.2 | DisplayString (SIZE (0..64)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-only · current The description of the software file purpose in this entry. | |||||||||||||||||||||
| CagentBscFileSystemServerAddr | 1.3.6.1.4.1.171.12.1.2.18.1.1.3 | IpAddress | RW | ||||||||||||||||||
column · IpAddress · read-write · current The IP address where the file to be downloaded is located, or the IP address where the file will be uploaded to. | |||||||||||||||||||||
| CagentBscFileSystemServerIPv6Addr | 1.3.6.1.4.1.171.12.1.2.18.1.1.4 | Ipv6Address | RW | ||||||||||||||||||
column · Ipv6Address · read-write · current The IPv6 address where the file is to be downloaded from or uploaded to. | |||||||||||||||||||||
| CagentBscFileSystemServerFileName | 1.3.6.1.4.1.171.12.1.2.18.1.1.5 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current The name of the file to be downloaded from or uploaded to the TFTP server.
If agentBscFileSystemDeviceFileName is not set, the switch will default to using
the bootup file as the runtime image for the switch. | |||||||||||||||||||||
| CagentBscFileSystemDeviceDriverID | 1.3.6.1.4.1.171.12.1.2.18.1.1.6 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Specifies the drive of the device that the firmware to be uploaded/downloaded is located. If none (1) is specified, the switch will default to the current drive.
| |||||||||||||||||||||
| CagentBscFileSystemDeviceFileName | 1.3.6.1.4.1.171.12.1.2.18.1.1.7 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current The name of the file to be downloaded to the device, or uploaded from the device. When downloading or uploading, the agentBscFileSystemServerFileName object must also be set. | |||||||||||||||||||||
| CagentBscFileSystemLoadType | 1.3.6.1.4.1.171.12.1.2.18.1.1.8 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object allows the user to select a download or upload function for the file. Note: For systems that do not support changes to this object, setting a value for this object will cause the system to return a bad-value error message.
| |||||||||||||||||||||
| CagentBscFileSystemCtrlUnitID | 1.3.6.1.4.1.171.12.1.2.18.1.1.9 | UnitList | RW | ||||||||||||||||||
column · UnitList · read-write · current Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12. If this list is set to null it represents all stack switches. | |||||||||||||||||||||
| CagentBscFileSystemBootUpImage | 1.3.6.1.4.1.171.12.1.2.18.1.1.10 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current The result of the download will depend on whether the boot_up option has been specified. Case 1: In the case of the master unit providing the file system and the slave unit not providing the file system, when the boot_up parameter is specified, then the file will be downloaded to the boot_up image on the slave. If the boot_up parameter is not specified, then the file will not be downloaded to this slave unit. Case 2: In the case of the master unit not providing the file system and the slave unit providing the file system, when the boot_up parameter is specified, then the file will be downloaded to the boot_up image on the slave unit. If boot_up is not specified, then the file will not be downloaded to this slave unit. Case 3: In the case of the master unit and the slave unit both supporting or not supporting the file system, the file will be downloaded to the specified file on the slave unit. If boot_up is specified, the downloaded file will be assigned as the boot_up image. True: boot_up option is specified. False: boot_up option is not specified.. | |||||||||||||||||||||
| CagentBscFileSystemForceAgree | 1.3.6.1.4.1.171.12.1.2.18.1.1.11 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current When the force_agree option is specified, the reboot command will be executed immediately without any further confirmation from the user. True: force_agree option is specified. False: force_agree option is not specified.. | |||||||||||||||||||||
| CagentBscFileSystemCtrl | 1.3.6.1.4.1.171.12.1.2.18.1.1.12 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object allows the user to download runtime software. The settings will take effect when the system restarts. See Note (1) below Note 1: For systems which do not support value changes to this object, setting these values will cause the system to return a bad-value error message start (3) - activate firmware.
| |||||||||||||||||||||
| CagentBscFileSystemInterfaceName | 1.3.6.1.4.1.171.12.1.2.18.1.1.13 | DisplayString (SIZE (0..12)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-write · current This node is used to specify the interface name when agentBscFileSystemServerIPv6Addr is the local link address. | |||||||||||||||||||||
| CagentBscFileSystemServerDomainName | 1.3.6.1.4.1.171.12.1.2.18.1.1.14 | DisplayString (SIZE (0..255)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..255)) · read-write · current This object indicates the domain name of the TFTP server. | |||||||||||||||||||||
| CagentBscFileSystemIncrement | 1.3.6.1.4.1.171.12.1.2.18.1.1.15 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current If increment is specified, then the existing configuration will not be cleared before applying of the new configuration. If it is not specified, then the existing configuration will be cleared before applying of the new configuration. True : keep valid False : erase. | |||||||||||||||||||||
| CagentBscFileSystemServerVrfName | 1.3.6.1.4.1.171.12.1.2.18.1.1.16 | DisplayString (SIZE (0..12)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-write · current This object indicates the VRF name of the TFTP server.Input string 'reserved' for the global space. | |||||||||||||||||||||
| SagentBscFileSystemSaveConfigDriverID | 1.3.6.1.4.1.171.12.1.2.18.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current The drive on the device that the configuration file is will be saved to. If none (1) is specified, the switch places the file on the current drive by default.
| |||||||||||||||||||||
| SagentBscFileSystemSaveConfigFileName | 1.3.6.1.4.1.171.12.1.2.18.3 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The name of the configuration file that will be saved to the device. When agentBscFileSystemSaveCfg is set to cfg (2), and if the agentBscFileSystemSaveConfigFileName is not null, the configuration file will be saved to the set file name. If set to null, the configuration file will be saved to the boot_up CFG file. | |||||||||||||||||||||
| SagentBscFileSystemSaveCfg | 1.3.6.1.4.1.171.12.1.2.18.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This indicates the method of saving information to the NV-RAM of the device. other (1) - None of the following. cfg (2) - Save configuration. log (3) - Save log. all (4) - Save both ( active configuration and log).
| |||||||||||||||||||||
| TagentFileSystemConfigTable | 1.3.6.1.4.1.171.12.1.2.18.5 | NA | |||||||||||||||||||
table · not-accessible · current This table indicates the information about the bootup files. | |||||||||||||||||||||
| RagentFileSystemConfigEntry | 1.3.6.1.4.1.171.12.1.2.18.5.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of information about the bootup files for each unit of the switch stack.
| |||||||||||||||||||||
| CagentFileSystemUnit | 1.3.6.1.4.1.171.12.1.2.18.5.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The unit ID. | |||||||||||||||||||||
| CagentFileSystemDriverID | 1.3.6.1.4.1.171.12.1.2.18.5.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current The drive on the device that the configuration file will be saved to. If none (1) is specified, the switch will place the file to the current drive by default.
| |||||||||||||||||||||
| CagentFileSystemBootImage | 1.3.6.1.4.1.171.12.1.2.18.5.1.3 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current When displayed, it shows the current bootup image file name. When set, the set name will be set as the bootup image. | |||||||||||||||||||||
| CagentFileSystemBootConfig | 1.3.6.1.4.1.171.12.1.2.18.5.1.4 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current When displayed, it shows the current bootup configuration file name. When set, the set name will be set as the bootup configuration. | |||||||||||||||||||||
| CagentFileSystemActConfig | 1.3.6.1.4.1.171.12.1.2.18.5.1.5 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current When displayed, it shows null. When set, the set name will be active at once, but the set name will not be set as the bootup configuration. | |||||||||||||||||||||
| SagentReboot | 1.3.6.1.4.1.171.12.1.2.19 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Used to restart the switch.
| |||||||||||||||||||||
| SagentReset | 1.3.6.1.4.1.171.12.1.2.20 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Used to reset all switch parameters.
none (1): No action. This is the default value of this object.
config (2): All parameters are reset to default settings.
The device will neither save nor reboot.
system (3): All parameters are reset to default settings.
The switch will then do a factory reset, save, and reboot.
reset (4) : All parameters will be reset to default settings except for the
IP address, user account, and history log.
The device will neither save nor reboot.
system-exclude-vlan(5) : All parameters are reset to default settings except for VLAN.
The switch will then save its settings and reboot.
system-exclude-ip(6) : All parameters are reset to default settings except IP address.
The switch will then save its settings and reboot.
system-exclude-vlan-ip(7): All parameters are reset to default settings except VLAN and IP address.
The switch will then save its settings and reboot.
| |||||||||||||||||||||
| TagentFTPFileTable | 1.3.6.1.4.1.171.12.1.2.21 | NA | |||||||||||||||||||
table · not-accessible · current A list of the MIB Basic Config entries support files updated by this agent. | |||||||||||||||||||||
| RagentFTPFileEntry | 1.3.6.1.4.1.171.12.1.2.21.1 | NA | |||||||||||||||||||
row · not-accessible · current A basic configuration entry containing the objects describing a particular MIB supported by this agent.
| |||||||||||||||||||||
| CagentFTPFileIndex | 1.3.6.1.4.1.171.12.1.2.21.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The table index for the file entry. This object describes the file type runtime-code (1), log-file (2), cfg-file (3) | |||||||||||||||||||||
| CagentFTPFileDscr | 1.3.6.1.4.1.171.12.1.2.21.1.2 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current The description of the software file purpose in this entry. Note: For systems which do not support changes to this object, setting a value for this object will cause the system to return bad-value error messages. | |||||||||||||||||||||
| CagentFTPFileLoadType | 1.3.6.1.4.1.171.12.1.2.21.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object provides the user with a choice of uploading or downloading the selected file. Note: For systems which do not support a change of this object, setting a value to this object will cause the system to return bad-value error messages.
| |||||||||||||||||||||
| CagentFTPFileAddr | 1.3.6.1.4.1.171.12.1.2.21.1.4 | IpAddress | RW | ||||||||||||||||||
column · IpAddress · read-write · current The IP address that the file to be downloaded is located on, or the IP address where the file will be uploaded to. | |||||||||||||||||||||
| CagentFTPTCPPort | 1.3.6.1.4.1.171.12.1.2.21.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current The TCP port number being used to establish the command connection. | |||||||||||||||||||||
| CagentFTPFileName | 1.3.6.1.4.1.171.12.1.2.21.1.6 | DisplayString (SIZE (0..128)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..128)) · read-write · current The name of the file to be downloaded from, or uploaded to, the FTP server. | |||||||||||||||||||||
| CagentFTPUserName | 1.3.6.1.4.1.171.12.1.2.21.1.7 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current This is the user name to enter in upload/download. | |||||||||||||||||||||
| CagentFTPPassword | 1.3.6.1.4.1.171.12.1.2.21.1.8 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current This is the password to enter for an upload/download. | |||||||||||||||||||||
| CagentFTPFileCtrlID | 1.3.6.1.4.1.171.12.1.2.21.1.9 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current The section ID of the firmware image or configuration file. A value of 0 indicates the boot-up firmware image or configuration file. | |||||||||||||||||||||
| CagentFTPFileBIncrement | 1.3.6.1.4.1.171.12.1.2.21.1.10 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current This object indicates whether the previous configuration will remain valid or not after downloading the configuration file. True: Keep valid False: Erase. | |||||||||||||||||||||
| CagentFTPFileCtrl | 1.3.6.1.4.1.171.12.1.2.21.1.11 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object gives the user the option to download runtime software. The setting will take effect
when the system restarts. See Note (1) below
Note 1:
For systems which do not support changes to this object, setting a value for this object
will cause the system to return bad-value error messages.
| |||||||||||||||||||||
| CagentFTPFileBootUpImage | 1.3.6.1.4.1.171.12.1.2.21.1.12 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current This object indicates whether to set the special file as a boot up file or not. True: The boot-up option is specified. False: The boot-up option is not specified. | |||||||||||||||||||||
| CagentFTPFileForceAgree | 1.3.6.1.4.1.171.12.1.2.21.1.13 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current When the force-agree option is specified, the reboot command will be executed immediately without any further confirmation from the user. True: Force-agree option is specified. False: Force-agree option is not specified. | |||||||||||||||||||||
| CagentFTPFileIPv6Addr | 1.3.6.1.4.1.171.12.1.2.21.1.14 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current The IPv6 address where the file is to be downloaded from or uploaded to. | |||||||||||||||||||||
| CagentFTPFileInterfaceName | 1.3.6.1.4.1.171.12.1.2.21.1.15 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current This node is used to specify the interface name when agentFTPFileIPv6Addr is the local link address. | |||||||||||||||||||||
| CagentFTPFileUnitID | 1.3.6.1.4.1.171.12.1.2.21.1.16 | UnitList | RW | ||||||||||||||||||
column · UnitList · read-write · current Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12.If this list is set to null it represents all stack switches. | |||||||||||||||||||||
| SagentSnmpTrapState | 1.3.6.1.4.1.171.12.1.2.22 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates if the SNMP trap is enabled or disabled.
| |||||||||||||||||||||
| NagentOutOfBandMgmt | 1.3.6.1.4.1.171.12.1.2.23 | ||||||||||||||||||||
| SagentOutOfBandMgmtState | 1.3.6.1.4.1.171.12.1.2.23.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enables or disables the interface.
| |||||||||||||||||||||
| SagentOutOfBandMgmtIpAddr | 1.3.6.1.4.1.171.12.1.2.23.2 | IpAddress | RW | ||||||||||||||||||
scalar · IpAddress · read-write · current The IP address for out of band management. This object can only take the value of the unicast IP address. | |||||||||||||||||||||
| SagentOutOfBandMgmtSubnetMask | 1.3.6.1.4.1.171.12.1.2.23.3 | IpAddress | RW | ||||||||||||||||||
scalar · IpAddress · read-write · current The IP net mask for out of band management. | |||||||||||||||||||||
| SagentOutOfBandMgmtGateway | 1.3.6.1.4.1.171.12.1.2.23.4 | IpAddress | RW | ||||||||||||||||||
scalar · IpAddress · read-write · current The gateway for out of band management. | |||||||||||||||||||||
| SagentOutOfBandMgmtLinkStatus | 1.3.6.1.4.1.171.12.1.2.23.5 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current The current Link status for out of band management.
| |||||||||||||||||||||
| NagentTrapMgmt | 1.3.6.1.4.1.171.12.1.2.24 | ||||||||||||||||||||
| SagentTrapColdStart | 1.3.6.1.4.1.171.12.1.2.24.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When enabled (1), whenever the device detects a cold start event, a trap will be sent out.
| |||||||||||||||||||||
| SagentTrapWarmStart | 1.3.6.1.4.1.171.12.1.2.24.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When enabled (1), whenever the device detects a warm start event, a trap will be sent out.
| |||||||||||||||||||||
| SagentTrapRmonRisingAlarm | 1.3.6.1.4.1.171.12.1.2.24.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When enabled (1), whenever the device detects a RMON rising alarm event , a trap will be sent out.
| |||||||||||||||||||||
| SagentTrapRmonFallingAlarm | 1.3.6.1.4.1.171.12.1.2.24.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When enabled (1), whenever the device detects a RMON falling alarm event, a trap will be sent out.
| |||||||||||||||||||||
| SagentTrapCfgSave | 1.3.6.1.4.1.171.12.1.2.24.5 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When enabled (1), whenever the device detects a configuration saving completed event, a trap will be sent out.
| |||||||||||||||||||||
| SagentTrapCfgUpload | 1.3.6.1.4.1.171.12.1.2.24.6 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When enabled (1), whenever the device detects a configuration uploading completed event, a trap will be sent out.
| |||||||||||||||||||||
| SagentTrapCfgDownload | 1.3.6.1.4.1.171.12.1.2.24.7 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current When enabled (1), whenever the device detects a configuration downloading completed event, a trap will be sent out
| |||||||||||||||||||||
| TagentFTPFileSystemTable | 1.3.6.1.4.1.171.12.1.2.25 | NA | |||||||||||||||||||
table · not-accessible · current The FTP management table for the file system | |||||||||||||||||||||
| RagentFTPFileSystemEntry | 1.3.6.1.4.1.171.12.1.2.25.1 | NA | |||||||||||||||||||
row · not-accessible · current A File System basic configuration entry that contains objects describing a particular MIB supported by this agent. | |||||||||||||||||||||
| CagentFTPFileSystemIndex | 1.3.6.1.4.1.171.12.1.2.25.1.1 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current The table index for the file entry. | |||||||||||||||||||||
| CagentFTPFileSystemDscr | 1.3.6.1.4.1.171.12.1.2.25.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The description of the software file purpose in this entry. | |||||||||||||||||||||
| CagentFTPFileSystemLoadType | 1.3.6.1.4.1.171.12.1.2.25.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object allows the user to select a download or upload function for the file.
| |||||||||||||||||||||
| CagentFTPFileSystemAddressType | 1.3.6.1.4.1.171.12.1.2.25.1.4 | InetAddressType | RW | ||||||||||||||||||
column · InetAddressType · read-write · current The address type of agentFTPFileSystemAddress. | |||||||||||||||||||||
| CagentFTPFileSystemAddress | 1.3.6.1.4.1.171.12.1.2.25.1.5 | InetAddress | RW | ||||||||||||||||||
column · InetAddress · read-write · current This object indicates the FTP server address. | |||||||||||||||||||||
| CagentFTPFileSystemTCPPort | 1.3.6.1.4.1.171.12.1.2.25.1.6 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current The TCP port number being used to establish the control connection. | |||||||||||||||||||||
| CagentFTPFileSystemServerFileName | 1.3.6.1.4.1.171.12.1.2.25.1.7 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current The name of the file to be downloaded from or uploaded to the FTP server. | |||||||||||||||||||||
| CagentFTPFileSystemDeviceFileName | 1.3.6.1.4.1.171.12.1.2.25.1.8 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..64)) · read-write · current The name of the file to be downloaded to the device, or uploaded from the device. If agentFTPFileSystemDeviceFileName is not set, the switch will default to the bootup file. | |||||||||||||||||||||
| CagentFTPFileSystemUserName | 1.3.6.1.4.1.171.12.1.2.25.1.9 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current This object indicates the user name to access the FTP server. | |||||||||||||||||||||
| CagentFTPFileSystemPassword | 1.3.6.1.4.1.171.12.1.2.25.1.10 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current This object indicates the password to access the FTP server. | |||||||||||||||||||||
| CagentFTPFileSystemCtrlUnitID | 1.3.6.1.4.1.171.12.1.2.25.1.11 | UnitList | RW | ||||||||||||||||||
column · UnitList · read-write · current Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from. One or more units can be set in this list. Each bit from left to right represents the switch from unit ID 1 to unit ID 12.If this list is set to null it represents all stack switches. | |||||||||||||||||||||
| CagentFTPFileSystemBootUpImage | 1.3.6.1.4.1.171.12.1.2.25.1.12 | TruthValue | RW | ||||||||||||||||||
column · TruthValue · read-write · current This object indicates whether to set the special file as the boot up file or not. True: The boot-up option is specified. False: The boot-up option is not specified. | |||||||||||||||||||||
| CagentFTPFileSystemCtrl | 1.3.6.1.4.1.171.12.1.2.25.1.13 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object allows the user to execute an FTP download/upload.
| |||||||||||||||||||||
| CagentFTPFileSystemVrfName | 1.3.6.1.4.1.171.12.1.2.25.1.14 | DisplayString (SIZE (0..12)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..12)) · read-write · current This object indicates the VRF name of the FTP server.Input string 'reserved' for the global space. | |||||||||||||||||||||
| SagentBscCMDLogState | 1.3.6.1.4.1.171.12.1.2.26 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates the command logging state.
| |||||||||||||||||||||
| SagentBscBroadcastPingReplyState | 1.3.6.1.4.1.171.12.1.2.27 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates the broadcast ping reply state.
| |||||||||||||||||||||
| NagentBscTftpConfigMgmt | 1.3.6.1.4.1.171.12.1.2.28 | ||||||||||||||||||||
| SagentBscTftpCfgFirmwareFile | 1.3.6.1.4.1.171.12.1.2.28.1 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgConfigFile | 1.3.6.1.4.1.171.12.1.2.28.2 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgLogFile | 1.3.6.1.4.1.171.12.1.2.28.3 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The log pathname that needs to be uploaded to the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgAttackLogFile | 1.3.6.1.4.1.171.12.1.2.28.4 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The attack log pathname that needs to be uploaded to the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgCertificateFile | 1.3.6.1.4.1.171.12.1.2.28.5 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The certificate pathname that needs to be downloaded from the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgKeyFile | 1.3.6.1.4.1.171.12.1.2.28.6 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The key pathname that needs to be downloaded from the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgTechSuooprtFile | 1.3.6.1.4.1.171.12.1.2.28.7 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The technique's support information pathname that needs to be uploaded to the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgDebugLogFile | 1.3.6.1.4.1.171.12.1.2.28.8 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The debug log pathname that needs to be uploaded to the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgSIMFirmwareFile | 1.3.6.1.4.1.171.12.1.2.28.9 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled. | |||||||||||||||||||||
| SagentBscTftpCfgSIMConfigFile | 1.3.6.1.4.1.171.12.1.2.28.10 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled. | |||||||||||||||||||||
| SagentBscTftpCfgSIMLogFile | 1.3.6.1.4.1.171.12.1.2.28.11 | DisplayString (SIZE (0..64)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-write · current The log pathname that needs to be uploaded to the TFTP server when it is SIM enabled. | |||||||||||||||||||||
| SagentBscTftpCfgServerIPAddr | 1.3.6.1.4.1.171.12.1.2.28.12 | IpAddress | RW | ||||||||||||||||||
scalar · IpAddress · read-write · current The IPv4 address of the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgServerIPv6Addr | 1.3.6.1.4.1.171.12.1.2.28.13 | Ipv6Address | RW | ||||||||||||||||||
scalar · Ipv6Address · read-write · current The IPv6 address of the TFTP server. | |||||||||||||||||||||
| SagentBscTftpCfgServerDomainName | 1.3.6.1.4.1.171.12.1.2.28.14 | DisplayString (SIZE (0..255)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..255)) · read-write · current The domain name of the TFTP server. | |||||||||||||||||||||
| SagentBscCommunityEncryptionState | 1.3.6.1.4.1.171.12.1.2.29 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates the encryption state on the SNMP community string.
| |||||||||||||||||||||
| SagentSnmpUdpPort | 1.3.6.1.4.1.171.12.1.2.30 | INTEGER (1..65535) | RW | ||||||||||||||||||
scalar · INTEGER (1..65535) · read-write · current This object indicates the snmp udp port number. | |||||||||||||||||||||
| SagentResponseBroadcastRequest | 1.3.6.1.4.1.171.12.1.2.31 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates the response broadcast request state.
| |||||||||||||||||||||
| NagentIpProtoConfig | 1.3.6.1.4.1.171.12.1.3 | ||||||||||||||||||||
| SagentIpNumOfIf | 1.3.6.1.4.1.171.12.1.3.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The total number of IP interfaces supported by this agent. | |||||||||||||||||||||
| SagentIpTftpServerAddr | 1.3.6.1.4.1.171.12.1.3.2 | IpAddress | RW | obsolete | |||||||||||||||||
scalar · IpAddress · read-write · obsolete The IP address of the TFTP Server. | |||||||||||||||||||||
| SagentIpGetIpFrom | 1.3.6.1.4.1.171.12.1.3.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current This object indicates if the agent will get its system IP address from a Bootp/DHCP server at start up.
| |||||||||||||||||||||
| SagentIpAutoconfig | 1.3.6.1.4.1.171.12.1.3.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Indicates the status of automatically getting the configuration information from a TFTP server connected to the device.
| |||||||||||||||||||||
| SagentIpAutoconfigTimeout | 1.3.6.1.4.1.171.12.1.3.5 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current This timer is used to limit the length of time for getting the configuration information from a TFTP server connected to the device. | |||||||||||||||||||||
| NagentIpTrapManager | 1.3.6.1.4.1.171.12.1.4 | ||||||||||||||||||||
| TagentTrapManagerTable | 1.3.6.1.4.1.171.12.1.4.2 | NA | |||||||||||||||||||
table · not-accessible · current A list of trap managers that the SNMP traps will be sent to. | |||||||||||||||||||||
| RagentTrapManagerEntry | 1.3.6.1.4.1.171.12.1.4.2.1 | NA | |||||||||||||||||||
row · not-accessible · current Each entry contains the particular trap manager's settings. | |||||||||||||||||||||
| CagentTrapManagerIndex | 1.3.6.1.4.1.171.12.1.4.2.1.1 | INTEGER (1..65535) | NA | ||||||||||||||||||
column · INTEGER (1..65535) · not-accessible · current A value that uniquely identifies trapDestEntry. | |||||||||||||||||||||
| CagentTrapManagerIpAddr | 1.3.6.1.4.1.171.12.1.4.2.1.2 | IpAddress | RW | ||||||||||||||||||
column · IpAddress · read-write · current The destination IP address for SNMP traps. | |||||||||||||||||||||
| CagentTrapManagerComm | 1.3.6.1.4.1.171.12.1.4.2.1.3 | DisplayString (SIZE (0..20)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..20)) · read-write · current The community string used to encode SNMP trap packets being sent to the trap manager. | |||||||||||||||||||||
| CagentTrapManagerMsgVer | 1.3.6.1.4.1.171.12.1.4.2.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object indicates the version of trap packets that will be sent to
this trap manager. The default setting is SNMP Agent Version Dependent.
Note:
Because some of these functions will be limited by the support of
the system in question, some selected items may be invalid. If one
of these items is selected, a bad value error message will prompt
the user.
| |||||||||||||||||||||
| CagentTrapManagerStatus | 1.3.6.1.4.1.171.12.1.4.2.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object indicates whether or not the trap should be sent to the trap manager.
| |||||||||||||||||||||
| CagentTrapManagerUdpPort | 1.3.6.1.4.1.171.12.1.4.2.1.6 | INTEGER (1..65535) | RW | ||||||||||||||||||
column · INTEGER (1..65535) · read-write · current This object indicates the Trap udp port number. | |||||||||||||||||||||
| TagentPortTrapStateTable | 1.3.6.1.4.1.171.12.1.4.3 | NA | |||||||||||||||||||
table · not-accessible · current Use to Set/Get per port trap state. | |||||||||||||||||||||
| RagentPortTrapStateEntry | 1.3.6.1.4.1.171.12.1.4.3.1 | NA | |||||||||||||||||||
row · not-accessible · current This is an entry of the agentPortTrapStateTable. | |||||||||||||||||||||
| CagentTrapStatePortIndex | 1.3.6.1.4.1.171.12.1.4.3.1.1 | INTEGER (1..65535) | NA | ||||||||||||||||||
column · INTEGER (1..65535) · not-accessible · current This object indicates the port number. | |||||||||||||||||||||
| CagentPortTrapState | 1.3.6.1.4.1.171.12.1.4.3.1.2 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current This object indicates the port trap status.
| |||||||||||||||||||||
| NagentNotify | 1.3.6.1.4.1.171.12.1.7 | ||||||||||||||||||||
| NagentNotifMgmt | 1.3.6.1.4.1.171.12.1.7.1 | ||||||||||||||||||||
| NnotifFirmwareMgmt | 1.3.6.1.4.1.171.12.1.7.1.2 | ||||||||||||||||||||
| NagentNotifFirmware | 1.3.6.1.4.1.171.12.1.7.2 | ||||||||||||||||||||
| NagentNotifyPrefix | 1.3.6.1.4.1.171.12.1.7.2.0 | ||||||||||||||||||||
| !agentsystemRestart | 1.3.6.1.4.1.171.12.1.7.2.0.1 | ||||||||||||||||||||
| !agentSaveToNVRAM | 1.3.6.1.4.1.171.12.1.7.2.0.2 | ||||||||||||||||||||
notification · current This trap is sent whenever all the device configuration has been saved to NV-RAM.
| |||||||||||||||||||||
| !agentFileTransferStatusChange | 1.3.6.1.4.1.171.12.1.7.2.0.3 | ||||||||||||||||||||
notification · current File transfer status change notification.
| |||||||||||||||||||||
| !agentSetToFactoryDefault | 1.3.6.1.4.1.171.12.1.7.2.0.4 | ||||||||||||||||||||
notification · current This trap is sent whenever the 'set to factory default' setting has been processed.
| |||||||||||||||||||||
| !agentGratuitousARPTrap | 1.3.6.1.4.1.171.12.1.7.2.0.5 | ||||||||||||||||||||
notification · current This trap is sent when there is an IP address conflict. | |||||||||||||||||||||
| !agentLoginFailTrap | 1.3.6.1.4.1.171.12.1.7.2.0.6 | ||||||||||||||||||||
notification · current The trap is sent when a login has failed through one of the login types (console, Telnet, web, SSL or SSH). | |||||||||||||||||||||
| !agentFirmwareUpgrade | 1.3.6.1.4.1.171.12.1.7.2.0.7 | ||||||||||||||||||||
notification · current This trap is sent when the process of upgrading the firmware via SNMP has finished.
| |||||||||||||||||||||
| !agentAccessFlashFailed | 1.3.6.1.4.1.171.12.1.7.2.0.8 | ||||||||||||||||||||
notification · current The trap is sent when access to the flash fails. | |||||||||||||||||||||
| !agentCfgOperCompleteTrap | 1.3.6.1.4.1.171.12.1.7.2.0.9 | ||||||||||||||||||||
notification · current The trap is sent when the configuration is completely saved, uploaded or downloaded.
| |||||||||||||||||||||
| NnotificationBindings | 1.3.6.1.4.1.171.12.1.7.2.1 | ||||||||||||||||||||
| SunitID | 1.3.6.1.4.1.171.12.1.7.2.1.1 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The unit ID of the device which triggered the event. | |||||||||||||||||||||
| StrapInfosystemRestart | 1.3.6.1.4.1.171.12.1.7.2.1.2 | DisplayString (SIZE (0..64)) | RO | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · read-only · current This object indicates the last time the device rebooted. | |||||||||||||||||||||
| SagentGratuitousARPIpAddr | 1.3.6.1.4.1.171.12.1.7.2.1.3 | IpAddress | AN | ||||||||||||||||||
scalar · IpAddress · accessible-for-notify · current A duplicate IP address with the switch already exists. | |||||||||||||||||||||
| SagentGratuitousARPMacAddr | 1.3.6.1.4.1.171.12.1.7.2.1.4 | MacAddress | AN | ||||||||||||||||||
scalar · MacAddress · accessible-for-notify · current This object is the MAC address of the device which has the duplicate IP address. | |||||||||||||||||||||
| SagentGratuitousARPPortNumber | 1.3.6.1.4.1.171.12.1.7.2.1.5 | DisplayString | AN | ||||||||||||||||||
scalar · DisplayString · accessible-for-notify · current This indicates the portNum with a string. For example, if the device is in standalone mode, and the port number is 23, the string should be 23. If the device is in stacking mode, and the unit ID is 2, and the port number is 3, the string should be 2:3. | |||||||||||||||||||||
| SagentLoginType | 1.3.6.1.4.1.171.12.1.7.2.1.6 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The type is the user login method type.
| |||||||||||||||||||||
| SagentLoginAAAMethod | 1.3.6.1.4.1.171.12.1.7.2.1.7 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current This method is the AAA login method.
| |||||||||||||||||||||
| SagentLoginUserName | 1.3.6.1.4.1.171.12.1.7.2.1.8 | DisplayString | AN | ||||||||||||||||||
scalar · DisplayString · accessible-for-notify · current This object is the name of the user that failed to login to the switch. | |||||||||||||||||||||
| SagentLoginIpAddr | 1.3.6.1.4.1.171.12.1.7.2.1.9 | IpAddress | AN | ||||||||||||||||||
scalar · IpAddress · accessible-for-notify · current This object is the login type from the IP address. | |||||||||||||||||||||
| SagentLoginMacAddr | 1.3.6.1.4.1.171.12.1.7.2.1.10 | MacAddress | AN | ||||||||||||||||||
scalar · MacAddress · accessible-for-notify · current This object is the login type from a MAC address. | |||||||||||||||||||||
| SagentLoginAAAServerAddr | 1.3.6.1.4.1.171.12.1.7.2.1.11 | IpAddress | AN | ||||||||||||||||||
scalar · IpAddress · accessible-for-notify · current This object is the login type through a console authenticated by an AAA server. | |||||||||||||||||||||
| SagentLoginFailInfo | 1.3.6.1.4.1.171.12.1.7.2.1.12 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current This object indicates the reason for the login failure.
| |||||||||||||||||||||
| SagentAccessFlashOper | 1.3.6.1.4.1.171.12.1.7.2.1.13 | DisplayString (SIZE (0..64)) | AN | ||||||||||||||||||
scalar · DisplayString (SIZE (0..64)) · accessible-for-notify · current This object indicates the operation of the access flash failure. | |||||||||||||||||||||
| SagentAccessFlashAddr | 1.3.6.1.4.1.171.12.1.7.2.1.14 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current This object indicates the address of the access flash failure. | |||||||||||||||||||||
| SagentCfgOperate | 1.3.6.1.4.1.171.12.1.7.2.1.15 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current This object indicates the operation type of the configuration.
| |||||||||||||||||||||
Textual conventions
Ipv6AddressOCTET STRING (SIZE (16))Display hint:
2x:This data type is used to model IPv6 addresses. This is a binary string of 16 octets in network byte-order.
Traps / Notifications
- agentAccessFlashFailed
1.3.6.1.4.1.171.12.1.7.2.0.8 - agentCfgOperCompleteTrap
1.3.6.1.4.1.171.12.1.7.2.0.9 - agentFileTransferStatusChange
1.3.6.1.4.1.171.12.1.7.2.0.3 - agentFirmwareUpgrade
1.3.6.1.4.1.171.12.1.7.2.0.7 - agentGratuitousARPTrap
1.3.6.1.4.1.171.12.1.7.2.0.5 - agentLoginFailTrap
1.3.6.1.4.1.171.12.1.7.2.0.6 - agentSaveToNVRAM
1.3.6.1.4.1.171.12.1.7.2.0.2 - agentSetToFactoryDefault
1.3.6.1.4.1.171.12.1.7.2.0.4 - agentsystemRestart
1.3.6.1.4.1.171.12.1.7.2.0.1