MIB for managing a DC power system with ORION. V6.60B22
snmptranslate -m ORION-BASE-MIB -Tpsnmpwalk -v2c -c <community> -m ORION-BASE-MIB <host> 1.3.6.1.4.1.20246.2.1.1.2Imports
| GLOBAL-REG | modules, orion |
|---|---|
| INET-ADDRESS-MIB | InetAddress |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IorionBaseMibModule | 1.3.6.1.4.1.20246.2.1.1.2 | ||||||||||||||||||||
identity MIB for managing a DC power system with ORION. V6.60B22 | |||||||||||||||||||||
| NorionBaseMib | 1.3.6.1.4.1.20246.2.3.1.1.1 | ||||||||||||||||||||
| NcontrollerConfs | 1.3.6.1.4.1.20246.2.3.1.1.1.1 | ||||||||||||||||||||
| NcontrollerGroups | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1 | ||||||||||||||||||||
| GsystemInfoGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.1 | ||||||||||||||||||||
group · current The collection of system info scalar objects. | |||||||||||||||||||||
| GsystemAlarmGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.2 | ||||||||||||||||||||
group · current The collection of system alarm scalar objects.
| |||||||||||||||||||||
| GsystemMonitorGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.3 | ||||||||||||||||||||
group · current The collection of system monitor scalar objects. | |||||||||||||||||||||
| GrectifierGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.4 | ||||||||||||||||||||
group · current The collection of rectifier scalar objects. | |||||||||||||||||||||
| GeventHistoryTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.5 | ||||||||||||||||||||
group · current The collection of event history table objects. | |||||||||||||||||||||
| GalarmTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.6 | ||||||||||||||||||||
group · current The collection of alarm table objects. | |||||||||||||||||||||
| GrectifierTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.7 | ||||||||||||||||||||
group · current The collection of rectifier table objects. | |||||||||||||||||||||
| GnotificationsGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.8 | ||||||||||||||||||||
group · current The group of all controller notifications. | |||||||||||||||||||||
| GgenericAlarmTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.9 | ||||||||||||||||||||
group · current Assignment of events to alarm table entries. | |||||||||||||||||||||
| GbatteryGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.10 | ||||||||||||||||||||
group · current The collection of battery scalar objects.
| |||||||||||||||||||||
| GcontrolEventTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.11 | ||||||||||||||||||||
group · current Assignment of control events to table entries. | |||||||||||||||||||||
| GtrapDestinationTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.12 | ||||||||||||||||||||
group · current Trap destionation table. | |||||||||||||||||||||
| GmiscGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.13 | ||||||||||||||||||||
group · current The collection of miscellaneous objects. | |||||||||||||||||||||
| GrectifierGroupTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.14 | ||||||||||||||||||||
group · current The collection of rectifier group table objects.
| |||||||||||||||||||||
| GbatteryStringTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.15 | ||||||||||||||||||||
group · current The collection of battery string table objects. | |||||||||||||||||||||
| GdefaultLogEventTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.16 | ||||||||||||||||||||
group · current The collection of default log event table objects. | |||||||||||||||||||||
| GeventProcessingEventTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.17 | ||||||||||||||||||||
group · current The collection of event processing event table objects. | |||||||||||||||||||||
| GlvdTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.18 | ||||||||||||||||||||
group · current The collection of LVD table objects. | |||||||||||||||||||||
| GpowerLimitationTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.19 | ||||||||||||||||||||
group · current The collection of power limitation table objects. | |||||||||||||||||||||
| GmeasurementTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.20 | ||||||||||||||||||||
group · current The collection of measurement table objects. | |||||||||||||||||||||
| GmeterPanelEventTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.21 | ||||||||||||||||||||
group · current The collection of meter panel event table objects. | |||||||||||||||||||||
| GmeterPanelmeasurementTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.22 | ||||||||||||||||||||
group · current The collection of meter panel measurement table objects. | |||||||||||||||||||||
| GbatteryLithiumTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.23 | ||||||||||||||||||||
group · current The collection of Lithium battery table objects. | |||||||||||||||||||||
| GbatteryLifePredictionTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.24 | ||||||||||||||||||||
group · current The collection of battery life prediction table objects. | |||||||||||||||||||||
| GpvcGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.25 | ||||||||||||||||||||
group · current The collection of PVC scalar objects. | |||||||||||||||||||||
| GpvcTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.26 | ||||||||||||||||||||
group · current The collection of PVC table objects. | |||||||||||||||||||||
| GpvcGroupTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.27 | ||||||||||||||||||||
group · current The collection of PVC Group table objects. | |||||||||||||||||||||
| GinventoryTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.28 | ||||||||||||||||||||
group · current The collection of inventory table objects. | |||||||||||||||||||||
| GeventDefinitionTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.29 | ||||||||||||||||||||
group · current The collection of event definition table objects.
| |||||||||||||||||||||
| GfilterTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.30 | ||||||||||||||||||||
group · current The collection of Filter table objects.
| |||||||||||||||||||||
| GtimerTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.31 | ||||||||||||||||||||
group · current The collection of timer table objects. | |||||||||||||||||||||
| GipGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.32 | ||||||||||||||||||||
group · current The collection of ip objects. | |||||||||||||||||||||
| GnewTrapDestinationTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.33 | ||||||||||||||||||||
group · current New Trap destionation table. | |||||||||||||||||||||
| GairconTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.34 | ||||||||||||||||||||
group · current Aircon table.
| |||||||||||||||||||||
| GinverterGroupTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.35 | ||||||||||||||||||||
group · current The collection of Inverter Group table objects.
| |||||||||||||||||||||
| GeventCtrlChargeTableTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.36 | ||||||||||||||||||||
group · current The collection of Event Controlled Charge Table Group table objects.
| |||||||||||||||||||||
| GbatteryTestTableTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.37 | ||||||||||||||||||||
group · current The collection of Battery Test Table Group table objects.
| |||||||||||||||||||||
| GbatteryTestResultTableTableGroup | 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.38 | ||||||||||||||||||||
group · current The collection of Battery Test Result Table Group table objects. | |||||||||||||||||||||
| NcontrollerCompl | 1.3.6.1.4.1.20246.2.3.1.1.1.1.2 | ||||||||||||||||||||
| McontrollerBasicCompl | 1.3.6.1.4.1.20246.2.3.1.1.1.1.2.1 | ||||||||||||||||||||
compliance · current The basic implementation requirements for the controller MIB. | |||||||||||||||||||||
| NcontrollerObjects | 1.3.6.1.4.1.20246.2.3.1.1.1.2 | ||||||||||||||||||||
| NdcSystemInfo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.1 | ||||||||||||||||||||
| SdcSiteName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.1 | DisplayString (SIZE (0..128)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..128)) · read-write · current An administratively-assigned site name for this DC-power system. | |||||||||||||||||||||
| SdcSystemName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.2 | DisplayString (SIZE (0..128)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (0..128)) · read-write · current An administratively-assigned system name for this DC-power system. | |||||||||||||||||||||
| SdcSystemDateTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.3 | DisplayString (SIZE (19)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (19)) · read-write · current ISO 8601 representation of controller's local date/time. The value is in the format YYYY-MM-DDThh:mm:ss. An example of a valid string is: '2004-10-04T13:45:00'. | |||||||||||||||||||||
| SdcSoftwareVersion | 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.4 | DisplayString (SIZE (10..12)) | RO | B8.35Build03 | |||||||||||||||||
scalar · DisplayString (SIZE (10..12)) · read-only · current The controller's software version e.g V2.50Build1. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdcCreateInventoryReport | 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.5 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Create the Inventory Report
| |||||||||||||||||||||
| NdcSystemAlarms | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2 | ||||||||||||||||||||
| TdcEventHistoryTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1 | NA | |||||||||||||||||||
table · not-accessible · current Controller's event history table that shows the content of the default log file. | |||||||||||||||||||||
| RdcEventHistoryEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1 | NA | |||||||||||||||||||
| CdcEventHistoryIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1.1 | Integer32 (1..10000) | NA | ||||||||||||||||||
column · Integer32 (1..10000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcEventHistoryTimestamp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1.2 | DisplayString (SIZE (19)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (19)) · read-only · current ISO8601 timestamp representation of a particular entry in the form YYYY-MM-DDThh:mm:ss. | |||||||||||||||||||||
| CdcEventHistoryMessage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1.3 | DisplayString (SIZE (1..255)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..255)) · read-only · current Event message of a particular entry. | |||||||||||||||||||||
| TdcAlarmTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows all active sent Traps. | |||||||||||||||||||||
| RdcAlarmEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1 | NA | |||||||||||||||||||
| CdcAlarmIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcAlarmEventCategory | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies the type of alarm source.
| |||||||||||||||||||||
| CdcAlarmEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.3 | DisplayString (SIZE (1..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..35)) · read-only · current Name of a particular alarm source entry. | |||||||||||||||||||||
| CdcAlarmEventIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.4 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Unique alarm event identifier. | |||||||||||||||||||||
| CdcAlarmEventValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Event status that corresponds to alarm event identifier.
| |||||||||||||||||||||
| SdcNumberUrgentAlarms | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.3 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Number of currently active urgent alarm sources. A zero value indicates that urgent alarm is not active. | |||||||||||||||||||||
| SdcNumberNonUrgentAlarms | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.4 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Number of currently active non urgent alarm sources. A zero value indicates that non urgent alarm is not active. | |||||||||||||||||||||
| SdcMainsFailureAlarm | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.5 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Mains failure alarm.
| |||||||||||||||||||||
| SdcUrgentAlarmIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.6 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Current unique urgent alarm event identifier. A zero value indicates that urgent alarm is not active. | |||||||||||||||||||||
| SdcUrgentAlarmValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.7 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Current urgent alarm event status that corresponds to the urgent alarm identifier. If the urgent alarm identifier is zero then the alarm value is false.
| |||||||||||||||||||||
| SdcNonUrgentAlarmIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.8 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Current unique non urgent alarm event identifier. A zero value indicates that non urgent alarm is not active. | |||||||||||||||||||||
| SdcNonUrgentAlarmValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.9 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Current non urgent alarm event status that corresponds to non urgent alarm identifier. If the non urgent alarm identifier is zero then the alarm value is false.
| |||||||||||||||||||||
| SdcUrgentAlarmName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.10 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
scalar · DisplayString (SIZE (0..35)) · read-only · current Current alarm name for urgent alarm that corresponds to urgent alarm identifier. | |||||||||||||||||||||
| SdcNonUrgentAlarmName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.11 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
scalar · DisplayString (SIZE (0..35)) · read-only · current Current alarm name for active non urgent alarm that corresponds to non urgent alarm identifier. | |||||||||||||||||||||
| TdcGenericAlarmTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows ten alarm event assignments that can be configured via WEB interface. | |||||||||||||||||||||
| RdcGenericAlarmEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1 | NA | |||||||||||||||||||
| CdcGenericAlarmIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcGenericAlarmEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.2 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current Plain text name of the assigned alarm event. Empty if not configured. | |||||||||||||||||||||
| CdcGenericAlarmEventIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.3 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Unique numeric identifier of the assigned alarm event. Zero if not configured. | |||||||||||||||||||||
| CdcGenericAlarmEventValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Current value of the assigned alarm event. Value is false if not configured.
| |||||||||||||||||||||
| SdcNumberCriticalAlarms | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.13 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Number of currently active critical alarm sources. A zero value indicates that critical alarm is not active. | |||||||||||||||||||||
| SdcCriticalAlarmIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.14 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Current unique critical alarm event identifier. A zero value indicates that critical alarm is not active. | |||||||||||||||||||||
| SdcCriticalAlarmValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.15 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Current critical alarm event status that corresponds to the critical alarm identifier. If the critical alarm identifier is zero then the alarm value is false.
| |||||||||||||||||||||
| SdcCriticalAlarmName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.16 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
scalar · DisplayString (SIZE (0..35)) · read-only · current Current alarm name for active critical alarm that corresponds to critical alarm identifier. | |||||||||||||||||||||
| SdcNumberAllAlarms | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.17 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Number of currently active all alarm sources. A zero value indicates that all alarm is not active. | |||||||||||||||||||||
| SdcAllAlarmIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.18 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Current unique all alarm event identifier. A zero value indicates that all alarm is not active. | |||||||||||||||||||||
| SdcAllAlarmValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.19 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Current all alarm event status that corresponds to the all alarm identifier. If the all alarm identifier is zero then the alarm value is false.
| |||||||||||||||||||||
| SdcAllAlarmName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.20 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
scalar · DisplayString (SIZE (0..35)) · read-only · current Current alarm name for active all alarm that corresponds to all alarm identifier. | |||||||||||||||||||||
| NdcSystemMonitor | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3 | ||||||||||||||||||||
| SdcSystemVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The measured system voltage. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| SdcLoadCurrent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.2 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The measured load current. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| SdcBatteryCurrent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.3 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The measured battery current. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| SdcBatteryTemperature | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.4 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The measured battery temperature. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| SdcChargeState | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.5 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Battery charge state.
| |||||||||||||||||||||
| SdcCurrentLimit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.6 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Battery current limit.
| |||||||||||||||||||||
| SdcRectifierCurrent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.7 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Total current of all working rectifier modules. The maximum value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| SdcSystemPower | 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.8 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Calculated system power. The maximum value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| NdcRectifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4 | ||||||||||||||||||||
| SdcNumberRectifiers | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.1 | Gauge32 (0..128) | RO | ||||||||||||||||||
scalar · Gauge32 (0..128) · read-only · current The configured number of rectifiers plugged into the system. The maximum number of rectifiersi is 128. | |||||||||||||||||||||
| SdcNumberRectifiersFailure | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.2 | Gauge32 (0..128) | RO | ||||||||||||||||||
scalar · Gauge32 (0..128) · read-only · current Number of rectifiers that are not properly working. | |||||||||||||||||||||
| SdcNumberRectifiersOkay | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.3 | Gauge32 (0..128) | RO | ||||||||||||||||||
scalar · Gauge32 (0..128) · read-only · current Number of rectifiers that are properly working. | |||||||||||||||||||||
| TdcRectifierTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows all currently active rectifier modules. | |||||||||||||||||||||
| RdcRectifierEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1 | NA | |||||||||||||||||||
| CdcRectifierIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.1 | Integer32 (1..128) | NA | ||||||||||||||||||
column · Integer32 (1..128) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcRectifierIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Unique rectifier identifier. If positioning active the position number scheme is used otherwise the rectifier instance is used to identify a rectifier. | |||||||||||||||||||||
| CdcRectifierSlotState | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies state of slots.
| |||||||||||||||||||||
| CdcRectifierMainStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies status of rectifiers.
| |||||||||||||||||||||
| CdcRectifierConfiguration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies configuration of rectifiers.
| |||||||||||||||||||||
| CdcRectifierIout | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured rectifier output current. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| CdcRectifierPout | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured rectifier output power. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| TdcRectifierGroupTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows all available rectifier groups. | |||||||||||||||||||||
| RdcRectifierGroupEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1 | NA | |||||||||||||||||||
| CdcRectifierGroupIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.1 | Integer32 (1) | NA | ||||||||||||||||||
column · Integer32 (1) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcRectifierGroupName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Rectifier group name to identify an individual device parameter set. | |||||||||||||||||||||
| CdcRectifierGroupRectifierType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Rectifier type defined for this group.
| |||||||||||||||||||||
| CdcRectifierGroupDefaultVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.4 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current This default voltage is used by rectifiers when there is no connection to ORION.
| |||||||||||||||||||||
| CdcRectifierGroupDefaultCurrentLimit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.5 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current This default current limit is used by rectifiers when there is no connection to ORION.
| |||||||||||||||||||||
| CdcRectifierGroupDefaultPowerLimit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current This default power limit is used by rectifiers when there is no connection to ORION.
| |||||||||||||||||||||
| CdcRectifierGroupInputLowOff | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Threshold for low AC input voltage. It can is used to adjust the behaviour of the power system to the available AC network limitation.
| |||||||||||||||||||||
| CdcRectifierGroupInputLowOn | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current For details see dcRectifierGroupInputLowOff.
| |||||||||||||||||||||
| CdcRectifierGroupStartupVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Startup parameters are the values that rectifiers use during the start-up phase. These parameters allow starting the system smoothly after a mains failure even on a discharged battery and even without ORION.
| |||||||||||||||||||||
| CdcRectifierGroupStartupCurrentLimit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.10 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current For details see dcRectifierGroupStartupVoltage.
| |||||||||||||||||||||
| CdcRectifierGroupStartupPowerLimit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.11 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current For details see dcRectifierGroupStartupVoltage.
| |||||||||||||||||||||
| CdcRectifierGroupStartupLimitTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.12 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current For details see dcRectifierGroupStartupVoltage.
| |||||||||||||||||||||
| CdcRectifierGroupPowerupDelay | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.13 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current This parameter is used after a mains failure to delay the start-up of all rectifiers.
| |||||||||||||||||||||
| CdcRectifierGroupPowerupTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.14 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current This parameter used after a mains failure and allows defining a time within all rectifiers needs to start-up one after another.
| |||||||||||||||||||||
| CdcRectifierGroupUmaxOff | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.15 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Overvoltage protection value.
| |||||||||||||||||||||
| NdcRectifierFunctions | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6 | ||||||||||||||||||||
| NdcEfficiencyCycling | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1 | ||||||||||||||||||||
| SdcEfficiencyCyclingEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable efficiency cycling.
| |||||||||||||||||||||
| SdcLimitSwitchingTimes | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.2 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable limit switching times.
| |||||||||||||||||||||
| SdcForceCyclingType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current If a period is set, then the Force Rectifier Cycling will occur once every period.
| |||||||||||||||||||||
| SdcMinimumPowerReserve | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.4 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Maximum load setup.
| |||||||||||||||||||||
| SdcMinimumRectifierPower | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.5 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Minimum load setup.
| |||||||||||||||||||||
| NdcPowerLimitation | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2 | ||||||||||||||||||||
| TdcPowerLimitationTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows parameters of the available power limitation functions. | |||||||||||||||||||||
| RdcPowerLimitationEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1 | NA | |||||||||||||||||||
| CdcPowerLimitationIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcPowerLimitationEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1.2 | DisplayString (SIZE (1..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..35)) · read-only · current Name of the power limitation event. | |||||||||||||||||||||
| CdcPowerLimitationStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Status of power limitation.
| |||||||||||||||||||||
| CdcPowerLimitationType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Power limitation type.
| |||||||||||||||||||||
| CdcMaxTotalRectifierPower | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1.5 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Limit used for power limitation.
| |||||||||||||||||||||
| CdcPowerLimitationNoBatteryDischarge | 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1.6 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Enable/disable no battery discharge during power limitation.
| |||||||||||||||||||||
| NdcBattery | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5 | ||||||||||||||||||||
| NdcFloatCharge | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.1 | ||||||||||||||||||||
| SdcUsys20 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.1.1 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Voltage to regulate to at 20°C(68°F). If temperature compensation is used, this voltage will vary.
| |||||||||||||||||||||
| NdcBatteryTest | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2 | ||||||||||||||||||||
| NdcBatteryTestParameter | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1 | ||||||||||||||||||||
| SdcBatteryTestUsupport | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.1 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete Support charge voltage for the battery.
| |||||||||||||||||||||
| SdcBatteryTestDuration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.2 | Gauge32 | RO | obsolete | |||||||||||||||||
scalar · Gauge32 · read-only · obsolete Battery test duration.
| |||||||||||||||||||||
| SdcBatteryTestInterval | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.3 | Gauge32 | RO | obsolete | |||||||||||||||||
scalar · Gauge32 · read-only · obsolete Minimal time between programmed battery tests as start condition.
| |||||||||||||||||||||
| SdcBatteryTestDischargeCurrent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.4 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete Battery discharge current. The maximum value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| SdcBatteryTestMinDuration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.5 | Gauge32 | RO | obsolete | |||||||||||||||||
scalar · Gauge32 · read-only · obsolete Minimum battery test duration during which time a battery test is not stopped in case of a voltage below the support voltage or a current difference higher than the specified value defined in Idiff measurement is detected.
| |||||||||||||||||||||
| SdcBatteryTestVoltageWithinUfloat | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.6 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete Battery voltage must be within Ufloat +/- set voltage for a given time (see also dcBatteryTestVoltageWithinUfloatPeriod) in order to start a battery test.
| |||||||||||||||||||||
| SdcBatteryTestVoltageWithinUfloatPeriod | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.7 | Gauge32 | RO | obsolete | |||||||||||||||||
scalar · Gauge32 · read-only · obsolete For details see dcBatteryTestVoltageWithinUfloat parameter.
| |||||||||||||||||||||
| SdcBatteryTestTempFrom | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.8 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete Battery temperature must be within temperature range given by dcBatteryTestTempFrom and dcBatteryTestTempTo, so that a battery test can be started.
| |||||||||||||||||||||
| SdcBatteryTestTempTo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.9 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete For details see dcBatteryTestTempFrom parameter.
| |||||||||||||||||||||
| SdcBatteryTestIntervalEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.10 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Enable/disable interval. For more details see dcBatteryTestInterval.
| |||||||||||||||||||||
| SdcBatteryTestStartTimeFrom | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.11 | DisplayString (SIZE (8)) | RO | obsolete | |||||||||||||||||
scalar · DisplayString (SIZE (8)) · read-only · obsolete Defines start time window for battery test. The possible time window is defined as the range between dcBatteryTestStartTimeFrom and dcBatteryTestStartTimeTo. The value is in the format 'hh:mm:ss'. | |||||||||||||||||||||
| SdcBatteryTestStartTimeTo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.12 | DisplayString (SIZE (8)) | RO | obsolete | |||||||||||||||||
scalar · DisplayString (SIZE (8)) · read-only · obsolete For details see dcBatteryTestStartTimeFrom. | |||||||||||||||||||||
| NdcBatteryTestResults | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2 | ||||||||||||||||||||
| SdcBatteryTestDateTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2.1 | DisplayString (SIZE (19)) | RO | obsolete | |||||||||||||||||
scalar · DisplayString (SIZE (19)) · read-only · obsolete ISO 8601 representation of the last performed battery test. The value is in the format YYYY-MM-DDThh:mm:ss. This parameter is valid only if there is a test result available. | |||||||||||||||||||||
| SdcBatteryTestResult | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2.2 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Result of last performed battery test.
| |||||||||||||||||||||
| SdcBatteryTestEndVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2.3 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete System voltage at the end of the last performed battery test. The maximum value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| SdcBatteryTestControl | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.3 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Start/stop of battery test. This special charge mode is used to check the capacity of a battery. Please note that a battery test can be started even if the battery is not fully charged. In this case the test result is ambiguous and the set failure event will become active.
| |||||||||||||||||||||
| SdcBatteryTestStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.4 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Status of battery test.
| |||||||||||||||||||||
| SdcBatteryTestFailureEvent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.5 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Reset battery test failure event.
| |||||||||||||||||||||
| SdcBatteryTestType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.6 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Battery test type used.
| |||||||||||||||||||||
| TdcBatteryTestTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7 | NA | |||||||||||||||||||
table · not-accessible · current Lists all the configured Battery Tests elements. | |||||||||||||||||||||
| RdcBatteryTestTableEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CdcBatteryTestTableIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.1 | Integer32 (1..10000) | NA | ||||||||||||||||||
column · Integer32 (1..10000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcBatteryTestTablePriority | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.2 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Priority of the battery test. Used as index for this table. | |||||||||||||||||||||
| CdcBatteryTestTableName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.3 | DisplayString (SIZE (32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (32)) · read-only · current Battery test name. | |||||||||||||||||||||
| CdcBatteryTestTableType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Battery test type used.
| |||||||||||||||||||||
| CdcBatteryTestTableStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Current status of battery test.
| |||||||||||||||||||||
| CdcBatteryTestTableUsupport | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Support charge voltage for the battery.
| |||||||||||||||||||||
| CdcBatteryTestTableDuration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.7 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current Battery test duration. Zero indicates that this value is not set.
| |||||||||||||||||||||
| CdcBatteryTestTableInterval | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.8 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current Minimal time between programmed battery tests as start condition.
| |||||||||||||||||||||
| CdcBatteryTestTableDischargeCurrent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.9 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Battery discharge current. The maximum value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| CdcBatteryTestTableMinDuration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.10 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current Minimum battery test duration during which time a battery test is not stopped in case of a voltage below the support voltage or a current difference higher than the specified value defined in Idiff measurement is detected.
| |||||||||||||||||||||
| CdcBatteryTestTableVoltageWithinUfloat | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.11 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Battery voltage must be within Ufloat +/- set voltage for a given time (see also dcBatteryTestTableVoltageWithinUfloatPeriod) in order to start a battery test.
| |||||||||||||||||||||
| CdcBatteryTestTableVoltageWithinUfloatPeriod | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.12 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current For details see dcBatteryTestTableVoltageWithinUfloat parameter.
| |||||||||||||||||||||
| CdcBatteryTestTableTempFrom | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.13 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Battery temperature must be within temperature range given by dcBatteryTestTableTempFrom and dcBatteryTestTableTempTo, so that a battery test can be started.
| |||||||||||||||||||||
| CdcBatteryTestTableTempTo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.14 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current For details see dcBatteryTestTableTempFrom parameter.
| |||||||||||||||||||||
| CdcBatteryTestTableIntervalEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.15 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Enable/disable interval. For more details see dcBatteryTestTableInterval.
| |||||||||||||||||||||
| CdcBatteryTestTableStartTimeFrom | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.16 | DisplayString (SIZE (8)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (8)) · read-write · current Defines start time window for battery test. The possible time window is defined as the range between dcBatteryTestTableStartTimeFrom and dcBatteryTestTableStartTimeTo. The value is in the format 'hh:mm:ss'. | |||||||||||||||||||||
| CdcBatteryTestTableStartTimeTo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.17 | DisplayString (SIZE (8)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (8)) · read-write · current For details see dcBatteryTestTableStartTimeFrom. | |||||||||||||||||||||
| CdcBatteryTestTableControl | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.18 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Manual Start/stop of battery test.
| |||||||||||||||||||||
| CdcBatteryTestTableFailureEvent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.7.1.19 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Reset the battery test failure event.
| |||||||||||||||||||||
| TdcBatteryTestResultTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8 | NA | |||||||||||||||||||
table · not-accessible · current Lists the results for all configured Battery Test elements. | |||||||||||||||||||||
| RdcBatteryTestResultTableEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CdcBatteryTestResultTableIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8.1.1 | Integer32 (1..10000) | NA | ||||||||||||||||||
column · Integer32 (1..10000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcBatteryTestResultTablePriority | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8.1.2 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Priority of the battery test. Used as index for this table. | |||||||||||||||||||||
| CdcBatteryTestResultTableName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8.1.3 | DisplayString (SIZE (32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (32)) · read-only · current Battery test name. | |||||||||||||||||||||
| CdcBatteryTestResultTableDateTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8.1.4 | DisplayString (SIZE (19)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (19)) · read-only · current ISO 8601 representation of the last performed battery test. The value is in the format YYYY-MM-DDThh:mm:ss. This parameter is valid only if there is a test result available. | |||||||||||||||||||||
| CdcBatteryTestResultTableResult | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Result of last performed battery test.
| |||||||||||||||||||||
| CdcBatteryTestResultTableEndVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.8.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current System voltage at the end of the last performed battery test. The maximum value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| NdcBatteryParameter | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3 | ||||||||||||||||||||
| SdcTotalBatteryCapacity | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.1 | Gauge32 | RO | ||||||||||||||||||
scalar · Gauge32 · read-only · current Total battery capacity for all available batteries.
| |||||||||||||||||||||
| TdcBatteryStringTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows parameters of the available battery strings. | |||||||||||||||||||||
| RdcBatteryStringEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1 | NA | |||||||||||||||||||
| CdcBatteryStringIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcBatteryStringName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Name of the battery string. | |||||||||||||||||||||
| CdcBatteryStringMaxIBatt | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.3 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Maximum battery charging current for this string. This parameter can be set individually for each battery. ORION then regulates the system voltage such that the maximum battery charging current of each battery is respected.
| |||||||||||||||||||||
| CdcBatteryStringCapacity | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.4 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current Capacity of battery can be defined individually. It is used to calculate the expected backup time of the system.
| |||||||||||||||||||||
| NdcLossOfBackupTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3 | ||||||||||||||||||||
| SdcLossOfBackupTimeEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable loss of backup time functionality.
| |||||||||||||||||||||
| SdcLossOfBackupTimeStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3.2 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Status of loss of backup time functionality.
| |||||||||||||||||||||
| SdcExpectedBackupTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3.3 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Expected backup time value. Based on the given value for the parameter expected backup time, the corresponding maximum discharge current is calculated.
| |||||||||||||||||||||
| TdcBatteryLithiumTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows parameters of the available Lithium batteries. | |||||||||||||||||||||
| RdcBatteryLithiumEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1 | NA | |||||||||||||||||||
| CdcBatteryLithiumIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcBatteryLithiumName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Name of the Lithium battery. | |||||||||||||||||||||
| CdcBatteryLithiumMainState | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Lithium Battery Main State.
| |||||||||||||||||||||
| CdcBatteryLithiumSubState | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Lithium Battery Sub-State.
| |||||||||||||||||||||
| CdcBatteryLithiumCurrent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Lithium battery current
| |||||||||||||||||||||
| CdcBatteryLithiumStateOfCharge | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.6 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Lithium battery state of charge
| |||||||||||||||||||||
| CdcBatteryLithiumInstallationDate | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.7 | DisplayString (SIZE (1..11)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..11)) · read-only · current Installation Date of the Lithium battery. | |||||||||||||||||||||
| CdcBatteryLithiumSoH | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.4.1.8 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Lithium battery state of health.
| |||||||||||||||||||||
| TdcBatteryLifePredictionTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.5 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows parameters of life prediction. | |||||||||||||||||||||
| RdcBatteryLifePredictionEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.5.1 | NA | |||||||||||||||||||
| CdcBatteryLifePredictionIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.5.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcBatteryLifePredictionName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.5.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Name of the battery. | |||||||||||||||||||||
| CdcBatteryLifePredictionRemainingDays | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.5.1.3 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Remaining days of battery. | |||||||||||||||||||||
| CdcBatteryLifePredictionInstallationDate | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.5.1.4 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Installation date of battery. | |||||||||||||||||||||
| CdcBatteryLifePredictionSoH | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.5.1.5 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Battery state of health. | |||||||||||||||||||||
| SdcBatteryLifePredictionStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.6 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Battery life prediction status.
| |||||||||||||||||||||
| SdcBatteryChargingCurrentLimitEnable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.7 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enables the Battery Charging Current limit.
| |||||||||||||||||||||
| SdcBatteryTotalChargingCurrentLimitEnable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.8 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enables battery charging current limit for total lithium batteries.
| |||||||||||||||||||||
| SdcBatteryTotalMaxIBatt | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.9 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Maximum battery charging current for total lithium batteries.
| |||||||||||||||||||||
| NdcEqualize | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4 | ||||||||||||||||||||
| SdcEqualizeControl | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Start/stop of battery equalize which is a special charge mode that applies a higher voltage to the batteries than the float charge. This ensures that the cells are all equally charged.
| |||||||||||||||||||||
| SdcEqualizeStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.2 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Current status of battery equalize.
| |||||||||||||||||||||
| SdcEqualizeEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable equalize.
| |||||||||||||||||||||
| NdcEqualizeParameter | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4 | ||||||||||||||||||||
| SdcEqualizeVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.1 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Voltage used for equalize.
| |||||||||||||||||||||
| SdcEqualizeDuration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.2 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Duration of equalize.
| |||||||||||||||||||||
| SdcEqualizeUseBattRoomFanEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable battery room fan during equalize.
| |||||||||||||||||||||
| SdcEqualizeLeadTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.4 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Lead time for equalize.
| |||||||||||||||||||||
| SdcEqualizeTimeLag | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.5 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Time lag for equalize.
| |||||||||||||||||||||
| SdcEqualizeInterval | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.6 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Interval for equalize as start condition.
| |||||||||||||||||||||
| SdcEqualizeStartTimeIntervalFrom | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.7 | DisplayString (SIZE (8)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (8)) · read-write · current Defines start time window for equqlize. The possible time window is defined as the range between dcEqualizeStartTimeIntervalFrom and dcEqualizeStartTimeIntervalTo. The value is in the format 'hh:mm:ss'. | |||||||||||||||||||||
| SdcEqualizeStartTimeIntervalTo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.8 | DisplayString (SIZE (8)) | RW | ||||||||||||||||||
scalar · DisplayString (SIZE (8)) · read-write · current For detail see dcEqualizeStartTimeIntervalFrom. | |||||||||||||||||||||
| SdcEqualizeInhibitAfterBoost | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.9 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Inhibit after boost as start condition.
| |||||||||||||||||||||
| NdcBoostCharge | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5 | ||||||||||||||||||||
| SdcBoostChargeControl | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Start/stop of boost charge which is a special charge mode that applies a higher voltage to the batteries than the float charge. This mode is started after a discharge phase to recharge the batteries faster.
| |||||||||||||||||||||
| SdcBoostChargeStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Current status of boost charge.
| |||||||||||||||||||||
| SdcBoostChargeType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Boost charge type.
| |||||||||||||||||||||
| NdcBoostChargeParameter | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4 | ||||||||||||||||||||
| SdcBoostChargeVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.1 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Voltage used for boost charge.
| |||||||||||||||||||||
| SdcBoostChargeMaxDuration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.2 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Defines the maximum allowed time for boost charge to prevent that the battery is charged forever.
| |||||||||||||||||||||
| SdcBoostChargeUseBattRoomFanEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.3 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable battery room fan during boost charge.
| |||||||||||||||||||||
| SdcBoostChargeTimeLag | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.4 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Time lag used for boost charge.
| |||||||||||||||||||||
| SdcBoostChargeIstart | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.5 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current For current based boost charge, the parameters Istart and Istop are the battery current values at which boost charge starts or stops.
| |||||||||||||||||||||
| SdcBoostChargeIstop | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current For details see dcBoostChargeIstart.
| |||||||||||||||||||||
| SdcBoostChargeInhibitTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.7 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current A start condition for all types of boost charge. It defines the time from last boost charge stop to the next acceptable boost charge start.
| |||||||||||||||||||||
| SdcBoostChargeSoCBelow | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4.8 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current A start condition for all types of boost charge. It defines the State of Charge (SoC) start condition.
| |||||||||||||||||||||
| NdcSystemVoltageSupervision | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6 | ||||||||||||||||||||
| SdcUaMax | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.1 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current If the system voltage is outside the range specified by the values UaMin (lower alarm voltage)/UaMax (upper alarm voltage), the system event 'S Ua low'/'S Ua high' is activated. The values for the parameters UaMin and UaMax are not temperature compensated.
| |||||||||||||||||||||
| SdcUaMin | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.2 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current For details see dcUaMax.
| |||||||||||||||||||||
| SdcUsMax | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.3 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current If the voltage is outside the range defined by the parameters UsMin (lower safety voltage)/UsMax (upper safety voltage), the system event 'S Us low'/'S Us high' is activated. If temperature compensation is enabled, the levels for Us min and / Us max are automatically temperature compensated to correspond to the required system voltage. The parameters are defined at 20°C(68°F).
| |||||||||||||||||||||
| SdcUsMin | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.4 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current For details see dcUsMax.
| |||||||||||||||||||||
| SdcBoD | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.5 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Voltage threshold for Battery on Discharge alarm.
| |||||||||||||||||||||
| SdcHysteresis | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Hysteresis used for Ua and Us.
| |||||||||||||||||||||
| SdcSuppressUaLowEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.7 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Suppress Ua Low alarm during mains failure.
| |||||||||||||||||||||
| SdcSuppressUsLowEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.8 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Suppress Us Low alarm during mains failure.
| |||||||||||||||||||||
| SdcEnableUsTempComp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.9 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Checkbox to enable the automatic temperature compensation for the Us thresholds (Us min, Us max).
| |||||||||||||||||||||
| NdcEvtCtrlCharge | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7 | ||||||||||||||||||||
| SdcEvtCtrlChargeStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.1 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Event control charge status.
| |||||||||||||||||||||
| SdcEvtCtrlChargeType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.2 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Selected event control charge type.
| |||||||||||||||||||||
| NdcEvtCtrlChargeParameter | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.3 | ||||||||||||||||||||
| SdcEvtCtrlChargeVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.3.1 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete Voltage used for event control charge.
| |||||||||||||||||||||
| SdcEvtCtrlChargeTempCompEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.3.2 | INTEGER | RO | obsolete | |||||||||||||||||
scalar · INTEGER · read-only · obsolete Enable/disable temperature compensation during event control obsolete.
| |||||||||||||||||||||
| SdcEvtCtrlChargeMaxIBatt | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.3.3 | Integer32 | RO | obsolete | |||||||||||||||||
scalar · Integer32 · read-only · obsolete Max. IBatt used for event control charge.
| |||||||||||||||||||||
| TdcEventControlledChargeTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4 | NA | |||||||||||||||||||
table · not-accessible · current Lists all the configured Event Controlled Charges elements. | |||||||||||||||||||||
| RdcEventControlledChargeTableEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1 | NA | |||||||||||||||||||
row · not-accessible · current | |||||||||||||||||||||
| CdcEventControlledChargeTableIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.1 | Integer32 (1..10000) | NA | ||||||||||||||||||
column · Integer32 (1..10000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcEventControlledChargeTablePriority | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.2 | Unsigned32 | RO | ||||||||||||||||||
column · Unsigned32 · read-only · current Priority of the event controlled charge instance. Used as index for this table. | |||||||||||||||||||||
| CdcEventControlledChargeTableName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.3 | DisplayString (SIZE (32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (32)) · read-only · current Event control charge name. | |||||||||||||||||||||
| CdcEventControlledChargeTableActivationInput | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.4 | DisplayString (SIZE (32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (32)) · read-only · current Event used to activate the controlled charge. | |||||||||||||||||||||
| CdcEventControlledChargeTableStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Event control charge current status.
| |||||||||||||||||||||
| CdcEventControlledChargeTableType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.6 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Selected event control charge type.
| |||||||||||||||||||||
| CdcEventControlledChargeTableVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.7 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Voltage used for event control charge.
| |||||||||||||||||||||
| CdcEventControlledChargeTableMaxIBatt | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Max. IBatt used for event control charge.
| |||||||||||||||||||||
| CdcEventControlledChargeTableTempCompEnabled | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.4.1.9 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Enable/disable temperature compensation during event control charge.
| |||||||||||||||||||||
| NdcTempComp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8 | ||||||||||||||||||||
| SdcTempCompType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.1 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Enable/disable battery temperature compensation.
| |||||||||||||||||||||
| SdcSlope | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.2 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Temperature compensation coefficient for system voltage.
| |||||||||||||||||||||
| SdcStartTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.3 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Lower limit for the area in which the temperature compensation is active.
| |||||||||||||||||||||
| SdcStopTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.4 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Upper limit for the area in which the temperature compensation is active.
| |||||||||||||||||||||
| SdcMaxVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.5 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Upper limit for the area in which the temperature compensation is not controlling the system voltage.
| |||||||||||||||||||||
| SdcLowStopVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.6 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The temperature compensation will not control the charging voltage above this parameter at low temperatures.
| |||||||||||||||||||||
| SdcLowStartTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.7 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current High temperature limit of the lower range.
| |||||||||||||||||||||
| SdcLowTempSlope | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.8 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Compensation factor applied inside the low range.
| |||||||||||||||||||||
| SdcHighStartTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.9 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The low temperature limit of the higher range.
| |||||||||||||||||||||
| SdcHighTempSlope | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.10 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Compensation factor applied inside the high range.
| |||||||||||||||||||||
| SdcHighStopVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.11 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current The temperature compensation will not control the charging voltage below this parameter at high temperatures.
| |||||||||||||||||||||
| SdcRunawayTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.12 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current A threshold for detecting thermal runaway of the battery.
| |||||||||||||||||||||
| SdcRunawayVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.13 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Charging voltage while Runaway Temp has been exceeded.
| |||||||||||||||||||||
| NdcTempSupervision | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.9 | ||||||||||||||||||||
| SdcHighTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.9.1 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Temperature threshold for high battery temperature alarm 10°C ... 70°C(50°F ... 158°F)
| |||||||||||||||||||||
| SdcHighTempHyst | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.9.2 | Integer32 | RW | ||||||||||||||||||
scalar · Integer32 · read-write · current Hysteresis for the High Temp 1°C ... 70°C(33.8°F ... 158°F)
| |||||||||||||||||||||
| NdcBatteryType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.10 | ||||||||||||||||||||
| SdcBatteryTypeSelect | 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.10.1 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current Select Battery Type.
| |||||||||||||||||||||
| NdcInputOutput | 1.3.6.1.4.1.20246.2.3.1.1.1.2.6 | ||||||||||||||||||||
| TdcControlEventTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows ten output event assignments that can be configured via WEB interface. | |||||||||||||||||||||
| RdcControlEventEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1 | NA | |||||||||||||||||||
| CdcControlEventIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.1 | Integer32 (1..16) | NA | ||||||||||||||||||
column · Integer32 (1..16) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcControlEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.2 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current Plain text name of the assigned control event. Empty if not configure. | |||||||||||||||||||||
| CdcControlEventIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.3 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Unique numeric identifier of the assigned control event. Zero if not configured. | |||||||||||||||||||||
| CdcControlEventValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Current value of the assigned control event. Value is false if not configured.
| |||||||||||||||||||||
| NdcMisc | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7 | ||||||||||||||||||||
| TdcTrapDestinationTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1 | NA | obsolete | ||||||||||||||||||
table · not-accessible · obsolete Trap table that shows all configured trap destinations. | |||||||||||||||||||||
| RdcTrapDestinationEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1 | NA | obsolete | ||||||||||||||||||
| CdcTrapDestinationIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1.1 | Integer32 (1..10) | NA | obsolete | |||||||||||||||||
column · Integer32 (1..10) · not-accessible · obsolete Table index. | |||||||||||||||||||||
| CdcTrapDestinationIp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1.2 | IpAddress | RW | obsolete | |||||||||||||||||
column · IpAddress · read-write · obsolete IP address of the trap destination. Value is 0.0.0.0 if IP address is not configured. | |||||||||||||||||||||
| CdcTrapDestinationPort | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1.3 | Gauge32 | RW | obsolete | |||||||||||||||||
column · Gauge32 · read-write · obsolete Port number of the trap destination. By default port 162 is used. | |||||||||||||||||||||
| CdcTrapDestinationUser | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1.4 | DisplayString (SIZE (0..32)) | RW | obsolete | |||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-write · obsolete User of the trap destination. | |||||||||||||||||||||
| SdcFileProcessingStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.2 | INTEGER | RO | ||||||||||||||||||
scalar · INTEGER · read-only · current File processing status for software and setup up/downloads.
| |||||||||||||||||||||
| SdcResendActiveAlarmTraps | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.4 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Resend all active Urgent, Non Urgent, and Critical Alarm Traps.
| |||||||||||||||||||||
| SdcRebootController | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.5 | INTEGER | RW | ||||||||||||||||||
scalar · INTEGER · read-write · current Reboot the Controller.
| |||||||||||||||||||||
| TdcTrapDestinationv2Table | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.6 | NA | |||||||||||||||||||
table · not-accessible · current Trap table that shows all configured trap destinations. | |||||||||||||||||||||
| RdcTrapDestinationv2Entry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.6.1 | NA | |||||||||||||||||||
| CdcTrapDestinationv2Index | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.6.1.1 | Integer32 (1..10) | NA | ||||||||||||||||||
column · Integer32 (1..10) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcTrapDestinationv2 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.6.1.2 | DisplayString | RW | ||||||||||||||||||
column · DisplayString · read-write · current Address of the trap destination. | |||||||||||||||||||||
| CdcTrapDestinationv2Port | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.6.1.3 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current Port number of the trap destination. | |||||||||||||||||||||
| CdcTrapDestinationv2User | 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.6.1.4 | DisplayString (SIZE (0..32)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-write · current User of the trap destination. | |||||||||||||||||||||
| NdcConfig | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8 | ||||||||||||||||||||
| TdcDefaultLogEventTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1 | NA | |||||||||||||||||||
table · not-accessible · current Event config table for default log. | |||||||||||||||||||||
| RdcDefaultLogEventEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1 | NA | |||||||||||||||||||
| CdcDefaultLogEventIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1.1 | Integer32 (0..1000) | NA | ||||||||||||||||||
column · Integer32 (0..1000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcDefaultLogEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1.2 | DisplayString (SIZE (1..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..35)) · read-only · current Plain text name of the event that can be logged. | |||||||||||||||||||||
| CdcDefaultLogEventLogged | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current If yes then this event is logged otherwise not.
| |||||||||||||||||||||
| TdcEventProcessingEventTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2 | NA | |||||||||||||||||||
table · not-accessible · current Event config table for event ORs. | |||||||||||||||||||||
| RdcEventProcessingEventEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1 | NA | |||||||||||||||||||
| CdcEventProcessingEventIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.1 | Integer32 (0..1000) | NA | ||||||||||||||||||
column · Integer32 (0..1000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcEventProcessingEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.2 | DisplayString (SIZE (1..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..35)) · read-only · current Plain text name of the input event. | |||||||||||||||||||||
| CdcEventProcessingEventAssigned | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.3 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current If yes then the input event is assigned to the selected event. Please note, that it is only possible to change assignment of event ORs.
| |||||||||||||||||||||
| CdcEventProcessingEventType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Type of the input event.
| |||||||||||||||||||||
| SdcEventProcessingEventSelected | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.3 | Gauge32 | RW | ||||||||||||||||||
scalar · Gauge32 · read-write · current Reference to dcEventProcessingEventIndex in order to select a specific event. | |||||||||||||||||||||
| TdcLvdTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4 | NA | |||||||||||||||||||
table · not-accessible · current Table lists all available LVDs. | |||||||||||||||||||||
| RdcLvdEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1 | NA | |||||||||||||||||||
| CdcLvdIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.1 | Integer32 (1..96) | NA | ||||||||||||||||||
column · Integer32 (1..96) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcLvdName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Name of the LVD. | |||||||||||||||||||||
| CdcLvdDisconnectDelay | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.3 | DisplayString (SIZE (8)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (8)) · read-write · current Time delay from the activation of the source event, after which the LVD event is switched. The value is in the format 'hh:mm:ss'. | |||||||||||||||||||||
| CdcLvdType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Type of the LVD.
| |||||||||||||||||||||
| CdcLvdVoltageThreshold | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.5 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Voltage threshold for U and t controlled type LVD. Only available in U and t Controlled Type LVDs.
| |||||||||||||||||||||
| CdcLvdVoltageHysteresis | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Voltage Hysteresis for U and t controlled type LVD. Only available in U and t Controlled Type LVDs.
| |||||||||||||||||||||
| CdcLvdControlEvent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.7 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current Control (previously named Source) Event for the LVD action. Only available in Event Controlled Type LVDs. | |||||||||||||||||||||
| CdcLvdMonitoringEvent | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.8 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current Monitoring Event. Only available in Event Controlled Type LVDs. | |||||||||||||||||||||
| TdcEventDefinitionTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.5 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows twenty threshold event assignments that can be configured via WEB interface. | |||||||||||||||||||||
| RdcEventDefinitionEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.5.1 | NA | |||||||||||||||||||
| CdcEventIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.5.1.1 | Integer32 (1..20) | NA | ||||||||||||||||||
column · Integer32 (1..20) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.5.1.2 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current Name of the threshold. | |||||||||||||||||||||
| CdcThreshold | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.5.1.3 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Value of the threshold. | |||||||||||||||||||||
| CdcThresholdHysteresis | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.5.1.4 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Hysteresis of the threshold. | |||||||||||||||||||||
| CdcUnit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.5.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Unit of the threshold
| |||||||||||||||||||||
| TdcFilterTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.6 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows twenty filter event assignments that can be configured via WEB interface. | |||||||||||||||||||||
| RdcFilterEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.6.1 | NA | |||||||||||||||||||
| CdcFilterIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.6.1.1 | Integer32 (1..20) | NA | ||||||||||||||||||
column · Integer32 (1..20) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcFilterName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.6.1.2 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current Name of the Filter. | |||||||||||||||||||||
| CdcTrueForMin | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.6.1.3 | DisplayString (SIZE (0..35)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-write · current True for Min. | |||||||||||||||||||||
| CdcFalseForMin | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.6.1.4 | DisplayString (SIZE (0..35)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-write · current False for Min. | |||||||||||||||||||||
| TdcTimerTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows twenty timer event assignments that can be configured via WEB interface. | |||||||||||||||||||||
| RdcTimerEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1 | NA | |||||||||||||||||||
| CdcTimerIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.1 | Integer32 (1..20) | NA | ||||||||||||||||||
column · Integer32 (1..20) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcTimerName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.2 | DisplayString (SIZE (0..35)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..35)) · read-only · current Name of the Timer. | |||||||||||||||||||||
| CdcStartTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.3 | DisplayString (SIZE (0..10)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..10)) · read-write · current Start Time(hh:mm). | |||||||||||||||||||||
| CdcStartDaySu | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.4 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Sunday Start Day?
| |||||||||||||||||||||
| CdcStartDayMo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.5 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Monday Start Day?
| |||||||||||||||||||||
| CdcStartDayTu | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.6 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Tuesday Start Day?
| |||||||||||||||||||||
| CdcStartDayWe | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.7 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Wednesday Start Day?
| |||||||||||||||||||||
| CdcStartDayTh | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.8 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Thursday Start Day?
| |||||||||||||||||||||
| CdcStartDayFr | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.9 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Friday Start Day?
| |||||||||||||||||||||
| CdcStartDaySa | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.10 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Saturday Start Day?
| |||||||||||||||||||||
| CdcEndTime | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.11 | DisplayString (SIZE (0..10)) | RW | ||||||||||||||||||
column · DisplayString (SIZE (0..10)) · read-write · current End Time(hh:mm). | |||||||||||||||||||||
| CdcEndDaySu | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.12 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Sunday End Day?
| |||||||||||||||||||||
| CdcEndDayMo | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.13 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Monday End Day?
| |||||||||||||||||||||
| CdcEndDayTu | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.14 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Tuesday End Day?
| |||||||||||||||||||||
| CdcEndDayWe | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.15 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Wednesday End Day?
| |||||||||||||||||||||
| CdcEndDayTh | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.16 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Thursday End Day?
| |||||||||||||||||||||
| CdcEndDayFr | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.17 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Friday End Day?
| |||||||||||||||||||||
| CdcEndDaySa | 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.7.1.18 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Is Saturday End Day?
| |||||||||||||||||||||
| NdcMeasurement | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9 | ||||||||||||||||||||
| TdcMeasurementTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1 | NA | |||||||||||||||||||
table · not-accessible · current Table lists all available measurements. | |||||||||||||||||||||
| RdcMeasurementEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1 | NA | |||||||||||||||||||
| CdcMeasurementIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.1 | Integer32 (1..500) | NA | ||||||||||||||||||
column · Integer32 (1..500) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcMeasurementName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.2 | DisplayString (SIZE (1..16)) | RO | AhInCntr | |||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Name of the measurement. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdcMeasurementValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.3 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Unscaled calibrated value of the measurement. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdcMeasurementScaleFactor | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.4 | Integer32 | RO | -1 | |||||||||||||||||
column · Integer32 · read-only · current Scale factor as power of 10 to be multiplied with measurement value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdcMeasurementUnit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.5 | INTEGER | RO | ampereHour(6) | |||||||||||||||||
column · INTEGER · read-only · current Unit of the measurement.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NdcMeterPanel | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10 | ||||||||||||||||||||
| TdcMeterPanelEventTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1 | NA | |||||||||||||||||||
table · not-accessible · current Table lists all available meter panel events. | |||||||||||||||||||||
| RdcMeterPanelEventEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1 | NA | |||||||||||||||||||
| CdcMeterPanelEventIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.1 | Integer32 (1..128) | NA | ||||||||||||||||||
column · Integer32 (1..128) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcMeterPanelEventName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.2 | DisplayString (SIZE (1..16)) | RO | HEX | |||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Name of the event. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdcMeterPanelEventValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.3 | INTEGER | RO | true(3) | |||||||||||||||||
column · INTEGER · read-only · current Value of the event.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdcMeterPanelEventHourMeterValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.4 | Gauge32 | RO | 0 | |||||||||||||||||
column · Gauge32 · read-only · current Value of the hour meter event.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TdcMeterPanelMeasurementTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.2 | NA | |||||||||||||||||||
table · not-accessible · current Table lists all available meter panel Measurements. | |||||||||||||||||||||
| RdcMeterPanelMeasurementEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.2.1 | NA | |||||||||||||||||||
row · not-accessible · current A particular meter panel Measurement entry. | |||||||||||||||||||||
| CdcMeterPanelMeasurementIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.2.1.1 | Integer32 (1..128) | NA | ||||||||||||||||||
column · Integer32 (1..128) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcMeterPanelMeasurementName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.2.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Name of the Measurement. | |||||||||||||||||||||
| CdcMeterPanelMeasurementValue | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.2.1.3 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Value of the Measurement. | |||||||||||||||||||||
| CdcMeterPanelMeasurementUnit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.2.1.4 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Unit of the measurement. | |||||||||||||||||||||
| NdcPVC | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11 | ||||||||||||||||||||
| SdcNumberPVCs | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.1 | Gauge32 (0..32) | RO | ||||||||||||||||||
scalar · Gauge32 (0..32) · read-only · current The configured number of PVCs plugged into the system. The maximum number of PVC is 32. | |||||||||||||||||||||
| SdcNumberPVCsFailure | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.2 | Gauge32 (0..32) | RO | ||||||||||||||||||
scalar · Gauge32 (0..32) · read-only · current Number of PVCs that are not properly working. | |||||||||||||||||||||
| SdcNumberPVCsOkay | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.3 | Gauge32 (0..32) | RO | ||||||||||||||||||
scalar · Gauge32 (0..32) · read-only · current Number of PVCs that are properly working. | |||||||||||||||||||||
| TdcPVCTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows all currently active PVC modules. | |||||||||||||||||||||
| RdcPVCEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1 | NA | |||||||||||||||||||
| CdcPVCIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.1 | Integer32 (1..32) | NA | ||||||||||||||||||
column · Integer32 (1..32) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcPVCIdentifier | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.2 | DisplayString (SIZE (1..16)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..16)) · read-only · current Unique PVC identifier. If positioning active the position number scheme is used otherwise the PVC instance is used to identify a PVC. | |||||||||||||||||||||
| CdcPVCSlotState | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies state of slots.
| |||||||||||||||||||||
| CdcPVCMainStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies status of PVCs.
| |||||||||||||||||||||
| CdcPVCSubStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies sub-status of PVCs.
| |||||||||||||||||||||
| CdcPVCConfiguration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Specifies configuration of PVCs.
| |||||||||||||||||||||
| CdcPVCIout | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured PVC output current. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| CdcPVCUout | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.8 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured PVC output voltage. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| CdcPVCIin | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.9 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured PVC input current. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| CdcPVCUin | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.4.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The measured PVC input voltage. The max. value 2147483647 is used to indicate an invalid value.
| |||||||||||||||||||||
| TdcPVCGroupTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows all available PVC groups. | |||||||||||||||||||||
| RdcPVCGroupEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1 | NA | |||||||||||||||||||
| CdcPVCGroupIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.1 | Integer32 (1) | NA | ||||||||||||||||||
column · Integer32 (1) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcPVCGroupPVCType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current PVC type defined for this group.
| |||||||||||||||||||||
| CdcPVCGroupVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.3 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current This default voltage is used by PVCs when there is no connection to ORION.
| |||||||||||||||||||||
| CdcPVCGroupVPGM | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.4 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current This is offset voltage used by PVCs.
| |||||||||||||||||||||
| CdcPVCGroupInputLowOff | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.5 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Threshold for low input voltage.
| |||||||||||||||||||||
| CdcPVCGroupInputLowOn | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.6 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current Threshold for low input voltage.
| |||||||||||||||||||||
| CdcPVCGroupStartUpDelay | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.7 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current This parameter is power up time of PVC that can be defined.
| |||||||||||||||||||||
| CdcPVCGroupOvpLimit | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.8 | Integer32 | RW | ||||||||||||||||||
column · Integer32 · read-write · current This voltage defines the maximum allowed DC-voltage.
| |||||||||||||||||||||
| CdcPVCGroupAlarmDelay | 1.3.6.1.4.1.20246.2.3.1.1.1.2.11.5.1.9 | Gauge32 | RW | ||||||||||||||||||
column · Gauge32 · read-write · current This parameter can be used for suppressing alarms during night time.
| |||||||||||||||||||||
| NdcInventory | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12 | ||||||||||||||||||||
| TdcInventoryTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1 | NA | |||||||||||||||||||
table · not-accessible · current Controller's inventory table that shows all inventory information. | |||||||||||||||||||||
| RdcInventoryEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1 | NA | |||||||||||||||||||
| CdcInventoryIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.1 | Integer32 (1..10000) | NA | ||||||||||||||||||
column · Integer32 (1..10000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcInventoryType | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.2 | DisplayString (SIZE (1..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Module type | |||||||||||||||||||||
| CdcInventoryName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.3 | DisplayString (SIZE (1..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Module name | |||||||||||||||||||||
| CdcInventorySwVersion | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.4 | DisplayString (SIZE (1..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Module software vision | |||||||||||||||||||||
| CdcInventoryBuildVersion | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.5 | DisplayString (SIZE (1..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Module software build vision | |||||||||||||||||||||
| CdcInventoryPartNb | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.6 | DisplayString (SIZE (1..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Module part number | |||||||||||||||||||||
| CdcInventorySerialNb | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.7 | DisplayString (SIZE (1..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Module serial number | |||||||||||||||||||||
| CdcInventoryTopLevel | 1.3.6.1.4.1.20246.2.3.1.1.1.2.12.1.1.8 | DisplayString (SIZE (1..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (1..32)) · read-only · current Module top level | |||||||||||||||||||||
| NdcIP | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13 | ||||||||||||||||||||
| NdcIPv4 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.1 | ||||||||||||||||||||
| SdcIPv4Address | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.1.1 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current The IP address in IPv4. | |||||||||||||||||||||
| SdcIPv4SubnetMask | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.1.2 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current The subnet mask address in IPv4. | |||||||||||||||||||||
| SdcIPv4Gateway | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.1.3 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current Gateway Address in IPv4. | |||||||||||||||||||||
| SdcIPv4DNS | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.1.4 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current The IP of Domain Name Server in IPv4. | |||||||||||||||||||||
| NdcIPv6 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.2 | ||||||||||||||||||||
| SdcIPv6LinkLocalAddress | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.2.1 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current Link Local address. | |||||||||||||||||||||
| SdcIPv6Address | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.2.2 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current The IP address in IPv6. | |||||||||||||||||||||
| SdcIPv6Gateway | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.2.3 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current Gateway address in IPv6. | |||||||||||||||||||||
| SdcIPv6DNSAuto | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.2.4 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current The IP of automatic Domain Name Server in IPv6. | |||||||||||||||||||||
| SdcIPv6DNSManual | 1.3.6.1.4.1.20246.2.3.1.1.1.2.13.2.5 | InetAddress | RO | ||||||||||||||||||
scalar · InetAddress · read-only · current The IP of manual Domain Name Server in IPv6. | |||||||||||||||||||||
| NdcAircon | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14 | ||||||||||||||||||||
| TdcAirconTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1 | NA | |||||||||||||||||||
table · not-accessible · current Aircon table that shows all Aircon and cooling plan information. | |||||||||||||||||||||
| RdcAirconEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1 | NA | |||||||||||||||||||
| CdcAirconIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.1 | Integer32 (1..10000) | NA | ||||||||||||||||||
column · Integer32 (1..10000) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcCoolingPlanIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.2 | Integer32 (1..10000) | NA | ||||||||||||||||||
column · Integer32 (1..10000) · not-accessible · current Cooling plan index | |||||||||||||||||||||
| CdcAirconName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.3 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Aircon module name | |||||||||||||||||||||
| CdcAirconMainStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Aircon module main status
| |||||||||||||||||||||
| CdcAirconSubStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Aircon module sub status
| |||||||||||||||||||||
| CdcAirconConfiguration | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Module configuration status
| |||||||||||||||||||||
| CdcAirconPlanName | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.7 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The name of cooling plan | |||||||||||||||||||||
| CdcAirconRoomTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.8 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Room temperature
| |||||||||||||||||||||
| CdcCoolingPlanActivationInput | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.9 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The input event for activate cooling plan | |||||||||||||||||||||
| CdcCoolingPlanPriority | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.10 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Cooling plan priority
| |||||||||||||||||||||
| CdcCoolingPlanStatus | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.11 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Cooling plan status
| |||||||||||||||||||||
| CdcCoolingPlanTargetTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.12 | Integer32 (250..1040) | RW | ||||||||||||||||||
column · Integer32 (250..1040) · read-write · current Cooling plan target temperature. The range is 25°C ... 40°C(77°F ... 104°F).
| |||||||||||||||||||||
| CdcCoolingPlanOperatingMode | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.13 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Cooling plan operating mode
| |||||||||||||||||||||
| CdcCoolingPlanStandbyFanSpeed | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.14 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Cooling plan standby fan speed
| |||||||||||||||||||||
| CdcCoolingPlanHeaterStartTemp | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.15 | Integer32 (-100..590) | RW | ||||||||||||||||||
column · Integer32 (-100..590) · read-write · current Cooling plan heater start temperature. The range is -10°C ... 15°C(14°F ... 59°F).
| |||||||||||||||||||||
| CdcCoolingPlanHeaterHyst | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.16 | Integer32 (10..180) | RW | ||||||||||||||||||
column · Integer32 (10..180) · read-write · current Cooling plan heater start temperature hysteresis. The range is 1°C ... 10°C(1.8°F ... 18°F).
| |||||||||||||||||||||
| CdcCoolingPlanHeaterControl | 1.3.6.1.4.1.20246.2.3.1.1.1.2.14.1.1.17 | INTEGER | RW | ||||||||||||||||||
column · INTEGER · read-write · current Cooling plan heater control mode
| |||||||||||||||||||||
| NdcInverter | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15 | ||||||||||||||||||||
| TdcInverterGroupTable | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1 | NA | |||||||||||||||||||
table · not-accessible · current Table that shows all available Inverter groups. | |||||||||||||||||||||
| RdcInverterGroupEntry | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1 | NA | |||||||||||||||||||
| CdcInverterGroupIndex | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.1 | Integer32 (1) | NA | ||||||||||||||||||
column · Integer32 (1) · not-accessible · current Table index. | |||||||||||||||||||||
| CdcInverterGroupState | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current This is the alarm state of the inverter system.
| |||||||||||||||||||||
| CdcInverterGroupLoadPosition | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Shows where is the load positioned in the system.
| |||||||||||||||||||||
| CdcInverterGroupNbrOfConfigInverters | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.4 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current The system is configure to operate this number of inverters at maximum. | |||||||||||||||||||||
| CdcInverterGroupNbrOfPresentInverters | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.5 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Number of inverters actually present in the system. | |||||||||||||||||||||
| CdcInverterGroupPhase | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.6 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current This is the alarm state of the inverter system. | |||||||||||||||||||||
| CdcInverterGroupDcVoltage | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input DC voltage
| |||||||||||||||||||||
| CdcInverterGroupInputDcPower | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.8 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input DC Power
| |||||||||||||||||||||
| CdcInverterGroupInputVoltage1 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.9 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input voltage line 1
| |||||||||||||||||||||
| CdcInverterGroupInputVoltage2 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input voltage line 2 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupInputVoltage3 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.11 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input voltage line 3 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupInputApparentPower1 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.12 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input power line 1
| |||||||||||||||||||||
| CdcInverterGroupInputApparentPower2 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.13 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input power line 2 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupInputApparentPower3 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.14 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Input power line 3 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupInputFrequency | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.15 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Input frequency
| |||||||||||||||||||||
| CdcInverterGroupOutputVoltage1 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.16 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Output voltage line 1
| |||||||||||||||||||||
| CdcInverterGroupOutputVoltage2 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.17 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Output voltage line 2 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupOutputVoltage3 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.18 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Output voltage line 3 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupOutputApparentPower1 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.19 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Output apparent power line 1
| |||||||||||||||||||||
| CdcInverterGroupOutputApparentPower2 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.20 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Output apparent power line 2 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupOutputApparentPower3 | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.21 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Output apparent power line 3 - in three phase system only
| |||||||||||||||||||||
| CdcInverterGroupOutputFrequency | 1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.22 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Output frequency
| |||||||||||||||||||||
| NcontrollerEvents | 1.3.6.1.4.1.20246.2.3.1.1.1.3 | ||||||||||||||||||||
| NcontrollerEventObjects | 1.3.6.1.4.1.20246.2.3.1.1.1.3.1 | ||||||||||||||||||||
| NcontrollerEventsV2 | 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0 | ||||||||||||||||||||
| !systemNonUrgentAlarm | 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.1 | ||||||||||||||||||||
notification · current The controller reports that one or more elements have changed into none urgent alarm state. | |||||||||||||||||||||
| !systemUrgentAlarm | 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.2 | ||||||||||||||||||||
notification · current The controller reports that one or more elements have changed into urgent alarm state. | |||||||||||||||||||||
| !systemCriticalAlarm | 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.3 | ||||||||||||||||||||
notification · current The controller reports that one or more elements have changed into critical alarm state. | |||||||||||||||||||||
| !systemAllAlarm | 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.4 | ||||||||||||||||||||
notification · current The controller reports that one Alarm Event state has changed. | |||||||||||||||||||||
Traps / Notifications
- systemAllAlarm
1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.4 - systemCriticalAlarm
1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.3 - systemNonUrgentAlarm
1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.1 - systemUrgentAlarm
1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.2
Groups and compliance
- airconTableGroup
- alarmTableGroup
- batteryGroup
- batteryLifePredictionTableGroup
- batteryLithiumTableGroup
- batteryStringTableGroup
- batteryTestResultTableTableGroup
- batteryTestTableTableGroup
- controlEventTableGroup
- controllerBasicCompl
- defaultLogEventTableGroup
- eventCtrlChargeTableTableGroup
- eventDefinitionTableGroup
- eventHistoryTableGroup
- eventProcessingEventTableGroup
- filterTableGroup
- genericAlarmTableGroup
- inventoryTableGroup
- inverterGroupTableGroup
- ipGroup
- lvdTableGroup
- measurementTableGroup
- meterPanelEventTableGroup
- meterPanelmeasurementTableGroup
- miscGroup
- newTrapDestinationTableGroup
- notificationsGroup
- powerLimitationTableGroup
- pvcGroup
- pvcGroupTableGroup
- pvcTableGroup
- rectifierGroup
- rectifierGroupTableGroup
- rectifierTableGroup
- systemAlarmGroup
- systemInfoGroup
- systemMonitorGroup
- timerTableGroup
- trapDestinationTableGroup