StorageManagement-MIB
Dell Inc.snmptranslate -m StorageManagement-MIB -Tpsnmpwalk -v2c -c <community> -m StorageManagement-MIB <host> 1.3.6.1.4.1.674Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Ndell | 1.3.6.1.4.1.674 | |||
| Nstorage | 1.3.6.1.4.1.674.10893 | |||
| Nsoftware | 1.3.6.1.4.1.674.10893.1 | |||
| NstorageManagement | 1.3.6.1.4.1.674.10893.1.20 | |||
| SsoftwareVersion | 1.3.6.1.4.1.674.10893.1.20.1 | DisplayString (SIZE (1..32)) | RO | mandatory |
scalar · DisplayString (SIZE (1..32)) · read-only · mandatory Version number of the storage management component of the systems management software. | ||||
| SglobalStatus | 1.3.6.1.4.1.674.10893.1.20.2 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Global health information for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group. Possible values: 1: Critical 2: Warning 3: Normal 4: Unknown
| ||||
| SsoftwareManufacturer | 1.3.6.1.4.1.674.10893.1.20.3 | DisplayString (SIZE (1..32)) | RO | mandatory |
scalar · DisplayString (SIZE (1..32)) · read-only · mandatory Manufacturer information for the Storage Management software. | ||||
| SsoftwareProduct | 1.3.6.1.4.1.674.10893.1.20.4 | DisplayString (SIZE (1..64)) | RO | mandatory |
scalar · DisplayString (SIZE (1..64)) · read-only · mandatory Product information for the Storage Management software. | ||||
| SsoftwareDescription | 1.3.6.1.4.1.674.10893.1.20.5 | DisplayString (SIZE (1..128)) | RO | mandatory |
scalar · DisplayString (SIZE (1..128)) · read-only · mandatory Product Description for the Storage Management software. | ||||
| NstorageManagementInfo | 1.3.6.1.4.1.674.10893.1.20.100 | |||
| SdisplayName | 1.3.6.1.4.1.674.10893.1.20.100.1 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory Name of this management software for display purposes. | ||||
| Sdescription | 1.3.6.1.4.1.674.10893.1.20.100.2 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory A short description of this management software. | ||||
| SagentVendor | 1.3.6.1.4.1.674.10893.1.20.100.3 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory The name of the management software manufacturer. | ||||
| SagentVersion | 1.3.6.1.4.1.674.10893.1.20.100.4 | DisplayString | RO | obsolete |
scalar · DisplayString · read-only · obsolete This entry is obsolete. Refer to softwareVersion. | ||||
| NglobalData | 1.3.6.1.4.1.674.10893.1.20.110 | |||
| SagentSystemGlobalStatus | 1.3.6.1.4.1.674.10893.1.20.110.1 | INTEGER | RO | obsolete |
scalar · INTEGER · read-only · obsolete This entry is obsolete. Please use the value: agentGlobalSystemStatus. Note: Enumerated values have changed.
| ||||
| SagentLastGlobalStatus | 1.3.6.1.4.1.674.10893.1.20.110.2 | INTEGER | RO | obsolete |
scalar · INTEGER · read-only · obsolete This entry is obsolete. Please use the value: agentLastGlobalSystemStatus. Note: Enumerated values have changed.
| ||||
| SagentTimeStamp | 1.3.6.1.4.1.674.10893.1.20.110.3 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory The last time that the agent values have been updated. Universal time in sec since UTC 1/1/70. | ||||
| SagentGetTimeout | 1.3.6.1.4.1.674.10893.1.20.110.4 | INTEGER (1..10000) | RO | mandatory |
scalar · INTEGER (1..10000) · read-only · mandatory Suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent. | ||||
| SagentModifiers | 1.3.6.1.4.1.674.10893.1.20.110.5 | INTEGER (1..10000) | RO | mandatory |
scalar · INTEGER (1..10000) · read-only · mandatory Agent functional modifiers, when set the modifier is active. Bit definitions: Bit 3: agent in debug mode. All other bits are product specific | ||||
| SagentRefreshRate | 1.3.6.1.4.1.674.10893.1.20.110.6 | INTEGER (1..10000) | RO | mandatory |
scalar · INTEGER (1..10000) · read-only · mandatory The rate, given in seconds, at which the cached data for SNMP is refreshed. The default value is 300 seconds, or 5 minutes. | ||||
| SagentHostname | 1.3.6.1.4.1.674.10893.1.20.110.7 | DisplayString | RO | obsolete |
scalar · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. | ||||
| SagentIPAddress | 1.3.6.1.4.1.674.10893.1.20.110.8 | DisplayString | RO | obsolete |
scalar · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. | ||||
| SagentSoftwareStatus | 1.3.6.1.4.1.674.10893.1.20.110.9 | INTEGER | RO | obsolete |
scalar · INTEGER · read-only · obsolete This entry is obsolete for Storage Management.
| ||||
| SagentSnmpVersion | 1.3.6.1.4.1.674.10893.1.20.110.10 | DisplayString | RO | obsolete |
scalar · DisplayString · read-only · obsolete This entry is obsolete. Refer to softwareVersion. | ||||
| SagentMibVersion | 1.3.6.1.4.1.674.10893.1.20.110.11 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory Version of the Storage Management MIB. | ||||
| SagentManagementSoftwareURLName | 1.3.6.1.4.1.674.10893.1.20.110.12 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory The Universal Resource Locator (URL) of the systems management software. | ||||
| SagentGlobalSystemStatus | 1.3.6.1.4.1.674.10893.1.20.110.13 | DellStatus | RO | mandatory |
scalar · DellStatus · read-only · mandatory Global health information for the subsystem managed by the Storage Management software. This global status should be used by applications other than HP OpenView. HP OpenView should refer to the globalStatus in the root level object group. This is a rollup for the entire agent including any monitored devices. The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| SagentLastGlobalSystemStatus | 1.3.6.1.4.1.674.10893.1.20.110.14 | DellStatus | RO | mandatory |
scalar · DellStatus · read-only · mandatory The previous global status of the system managed by the Storage Management software. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| SagentSmartThermalShutdown | 1.3.6.1.4.1.674.10893.1.20.110.15 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Indicates the status of smart thermal shutdown for PV220S and PV221S enclosures. Possible values: 1: Enabled 2: Disabled
| ||||
| NphysicalDevices | 1.3.6.1.4.1.674.10893.1.20.130 | |||
| TcontrollerTable | 1.3.6.1.4.1.674.10893.1.20.130.1 | NA | mandatory | |
table · not-accessible · mandatory A table of managed RAID controllers. The number of entries is related to number of RAID controllers discovered in the system. Note: The properties in this table may not be applicable to all entries. | ||||
| RcontrollerEntry | 1.3.6.1.4.1.674.10893.1.20.130.1.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CcontrollerNumber | 1.3.6.1.4.1.674.10893.1.20.130.1.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this controller entry. | ||||
| CcontrollerName | 1.3.6.1.4.1.674.10893.1.20.130.1.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example: Perc3/QC 1. | ||||
| CcontrollerVendor | 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The controller's (re)seller's name. | ||||
| CcontrollerType | 1.3.6.1.4.1.674.10893.1.20.130.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type of this controller: 1: SCSI 2: PV660F 3: PV662F 4: IDE (Integrated/Intelligent Drive Electronics) 5: SATA (Serial Advanced Technology Attachment) 6: SAS (Serial Attached SCSI) 9: PCIe SSD
| ||||
| CcontrollerState | 1.3.6.1.4.1.674.10893.1.20.130.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the controller's subsystem (which includes any devices connected to it.) Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded
| ||||
| CcontrollerSeverity | 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CcontrollerRebuildRateInPercent | 1.3.6.1.4.1.674.10893.1.20.130.1.1.7 | INTEGER (0..100) | RO | mandatory |
column · INTEGER (0..100) · read-only · mandatory The percent of the compute cycles dedicated to rebuilding failed array disks. | ||||
| CcontrollerFWVersion | 1.3.6.1.4.1.674.10893.1.20.130.1.1.8 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The controller's current firmware version. | ||||
| CcontrollerCacheSizeInMB | 1.3.6.1.4.1.674.10893.1.20.130.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The controller's current amount of cache memory in megabytes. If this size is 0, it is less than a megabyte. | ||||
| CcontrollerCacheSizeInBytes | 1.3.6.1.4.1.674.10893.1.20.130.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The controller's current amount of cache memory that is less than a megabyte. This combined with the controllerCacheSizeInMB will be the total amount of memory. | ||||
| CcontrollerPhysicalDeviceCount | 1.3.6.1.4.1.674.10893.1.20.130.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Number of physical devices on the controller channel including both disks and the controller. | ||||
| CcontrollerLogicalDeviceCount | 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Number of virtual disks on the controller. | ||||
| CcontrollerPartnerStatus | 1.3.6.1.4.1.674.10893.1.20.130.1.1.13 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. | ||||
| CcontrollerHostPortCount | 1.3.6.1.4.1.674.10893.1.20.130.1.1.14 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerMemorySizeInMB | 1.3.6.1.4.1.674.10893.1.20.130.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. This attribute is only supported on Adaptec controllers. | ||||
| CcontrollerMemorySizeInBytes | 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB will be the total size of the memory. This attribute is only supported on Adaptec controllers. | ||||
| CcontrollerDriveChannelCount | 1.3.6.1.4.1.674.10893.1.20.130.1.1.17 | INTEGER (1..4) | RO | obsolete |
column · INTEGER (1..4) · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerFaultTolerant | 1.3.6.1.4.1.674.10893.1.20.130.1.1.18 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This entry is obsolete. Fibre channel is not supported in Storage Management.
| ||||
| CcontrollerC0Port0WWN | 1.3.6.1.4.1.674.10893.1.20.130.1.1.19 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC0Port0Name | 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC0Port0ID | 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC0Target | 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC0Channel | 1.3.6.1.4.1.674.10893.1.20.130.1.1.23 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC0OSController | 1.3.6.1.4.1.674.10893.1.20.130.1.1.24 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC0BatteryState | 1.3.6.1.4.1.674.10893.1.20.130.1.1.25 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management.
| ||||
| CcontrollerC1Port0WWN | 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC1Port0Name | 1.3.6.1.4.1.674.10893.1.20.130.1.1.27 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC1Port0ID | 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC1Target | 1.3.6.1.4.1.674.10893.1.20.130.1.1.29 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC1Channel | 1.3.6.1.4.1.674.10893.1.20.130.1.1.30 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC1OSController | 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC1BatteryState | 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management.
| ||||
| CcontrollerNodeWWN | 1.3.6.1.4.1.674.10893.1.20.130.1.1.33 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC0Port1WWN | 1.3.6.1.4.1.674.10893.1.20.130.1.1.34 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerC1Port1WWN | 1.3.6.1.4.1.674.10893.1.20.130.1.1.35 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerBatteryChargeCount | 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. Fibre channel is not supported in Storage Management. | ||||
| CcontrollerRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.1.1.37 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CcontrollerComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.1.1.38 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CcontrollerNexusID | 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this controller. | ||||
| CcontrollerAlarmState | 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory State, or setting for the controller's alarm. Possible values: 1: Enabled 2: Disabled 3: Not Applicable
| ||||
| CcontrollerDriverVersion | 1.3.6.1.4.1.674.10893.1.20.130.1.1.41 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Currently installed driver version for this controller. | ||||
| CcontrollerPCISlot | 1.3.6.1.4.1.674.10893.1.20.130.1.1.42 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The PCI slot number or embedded number for controllers on the motherboard. For Modular or NGM controllers, the PCI Slot Designation or Embedded is displayed. | ||||
| CcontrollerClusterMode | 1.3.6.1.4.1.674.10893.1.20.130.1.1.43 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Identifies if the controller is in cluster mode. Possible values: 1 : Enabled 2 : Disabled 3 : Active (enabled and active) 99: Not Applicable
| ||||
| CcontrollerMinFWVersion | 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The minimum firmware version for Storage Management to support the controller. | ||||
| CcontrollerMinDriverVersion | 1.3.6.1.4.1.674.10893.1.20.130.1.1.45 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The minimum driver version for Storage Management to support the controller. | ||||
| CcontrollerSCSIInitiatorID | 1.3.6.1.4.1.674.10893.1.20.130.1.1.46 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The SCSI ID of the initiator. | ||||
| CcontrollerChannelCount | 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Number of channels on the controller. | ||||
| CcontrollerReconstructRate | 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The rate for reconstruct on the controller. | ||||
| CcontrollerPatrolReadRate | 1.3.6.1.4.1.674.10893.1.20.130.1.1.49 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The rate for patrol read on the controller. | ||||
| CcontrollerBGIRate | 1.3.6.1.4.1.674.10893.1.20.130.1.1.50 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The rate for background initialization on the controller. | ||||
| CcontrollerCheckConsistencyRate | 1.3.6.1.4.1.674.10893.1.20.130.1.1.51 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The rate for check consistency on the controller. | ||||
| CcontrollerPatrolReadMode | 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Identifies the patrol read mode. Possible values: 1: Automatic (enabled) 2: Manual (enabled) 3: Disabled
| ||||
| CcontrollerPatrolReadState | 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The state of the patrol read. 1: Stopped - not running 2: Ready - ready to start 4: Active - is running 8: Aborted - has aborted
| ||||
| CcontrollerPatrolReadIterations | 1.3.6.1.4.1.674.10893.1.20.130.1.1.54 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of times Patrol Read has been run on this controller. | ||||
| CcontrollerStorportDriverVersion | 1.3.6.1.4.1.674.10893.1.20.130.1.1.55 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Provide current Windows OS storport driver version. Not applicable for Linux. | ||||
| CcontrollerMinRequiredStorportVer | 1.3.6.1.4.1.674.10893.1.20.130.1.1.56 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Provides minimum required storport driver version for Windows OS only. | ||||
| CcontrollerEncryptionCapable | 1.3.6.1.4.1.674.10893.1.20.130.1.1.57 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates Encryption capability of the controller. Value: 1 - Capable, 99 - NotApplicable | ||||
| CcontrollerEncryptionKeyPresent | 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Indicates presence of Encryption Key for the controller. Value: 1 - Yes, 0 - No, 99 - NotApplicable | ||||
| CcontrollerPersistentHotSpare | 1.3.6.1.4.1.674.10893.1.20.130.1.1.59 | INTEGER (0..1) | RO | mandatory |
column · INTEGER (0..1) · read-only · mandatory Indicates Persistent Hot Spare capability of the controller Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined / Not applicable | ||||
| CcontrollerSpinDownUnconfiguredDrives | 1.3.6.1.4.1.674.10893.1.20.130.1.1.60 | INTEGER (0..1) | RO | mandatory |
column · INTEGER (0..1) · read-only · mandatory Indicates controller capability to put unconfigured drives in power save mode. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined / Not applicable | ||||
| CcontrollerSpinDownHotSpareDrives | 1.3.6.1.4.1.674.10893.1.20.130.1.1.61 | INTEGER (0..1) | RO | mandatory |
column · INTEGER (0..1) · read-only · mandatory Indicates controller capability to put hot spare drives in power save mode. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined / Not applicable | ||||
| CcontrollerSpinDownTimeInterval | 1.3.6.1.4.1.674.10893.1.20.130.1.1.62 | INTEGER (30..1440) | RW | mandatory |
column · INTEGER (30..1440) · read-write · mandatory Shows the duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode. Value: 30 to 1440 Note: A value of 9999 indicates feature not available. | ||||
| CcontrollerEncryptionMode | 1.3.6.1.4.1.674.10893.1.20.130.1.1.63 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the current encryption mode of the controller. Value: 0 - No Encryption, 1 - Local Key Management (LKM), 2 - Secure Enterprise Key Management (SEKM), 99 - Not Applicable | ||||
| CcontrollerCacheCade | 1.3.6.1.4.1.674.10893.1.20.130.1.1.64 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if the controller is CacheCade capable or not. Value: 1 - Capable, 0 - Not Capable, 99 - Undetermined | ||||
| CcontrollerSpinDownConfiguredDrives | 1.3.6.1.4.1.674.10893.1.20.130.1.1.65 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates controller capability to spin down configured physical disks. Value: 0 - Disabled, 1 - Enabled, 99 - Undetermined | ||||
| CcontrollerAutomaticPowerSaving | 1.3.6.1.4.1.674.10893.1.20.130.1.1.66 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates controller capability for automatic power saving. Value: 0 - Disabled, 1 - Enabled, 99 - Undetermined | ||||
| CcontrollerConfiguredDrivesSpinUpTime | 1.3.6.1.4.1.674.10893.1.20.130.1.1.67 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Indicates configured drives spin up start time. Value: 1:00 AM to 12:59 PM, 9999 - Undetermined | ||||
| CcontrollerConfiguredDrivesSpinUpTimeInterval | 1.3.6.1.4.1.674.10893.1.20.130.1.1.68 | INTEGER (30..1440) | RO | mandatory |
column · INTEGER (30..1440) · read-only · mandatory Indicates configured drives spin up time interval in hours. This value is added with configured drives start time to arrive at time window in which configured drives are always spin up. Value: 1 .. 24, 9999 - Undetermined | ||||
| CcontrollerPreservedCache | 1.3.6.1.4.1.674.10893.1.20.130.1.1.69 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if preserved cache is present on the controller. Values: 1- Yes, 0 - No, 99 - Not available / Not applicable | ||||
| CcontrollerPIEnable | 1.3.6.1.4.1.674.10893.1.20.130.1.1.70 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if T10 PI is enabled on a controller. Value can be either 0 (T10 PI disabled) or 1 (T10 PI enabled). | ||||
| CcontrollerCurrentMode | 1.3.6.1.4.1.674.10893.1.20.130.1.1.71 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Shows the current controller mode. | ||||
| CfrontChassisSlot | 1.3.6.1.4.1.674.10893.1.20.130.1.1.72 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Shows the physical slot on the chassis for stash . | ||||
| CcontrollerInstance | 1.3.6.1.4.1.674.10893.1.20.130.1.1.73 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Shows the current instance of the controller for stash . | ||||
| CcontrollerNonRAIDdiskCachePolicy | 1.3.6.1.4.1.674.10893.1.20.130.1.1.74 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Displays the current disk write cache policy for Non-RAID disks. | ||||
| CcontrollerAutoconfigureBehavior | 1.3.6.1.4.1.674.10893.1.20.130.1.1.75 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Displays the current auto configure behavior mode on controller. | ||||
| TchannelTable | 1.3.6.1.4.1.674.10893.1.20.130.2 | NA | mandatory | |
table · not-accessible · mandatory A table of controller channels. The number of entries is related to the number of channels supported by a RAID controller. Perc2 RAID controller supports a max of 4 channels per controller. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RchannelEntry | 1.3.6.1.4.1.674.10893.1.20.130.2.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the channel table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CchannelNumber | 1.3.6.1.4.1.674.10893.1.20.130.2.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this channel entry. | ||||
| CchannelName | 1.3.6.1.4.1.674.10893.1.20.130.2.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the channel as represented in Storage Management. The name will include the word channel and the instance. For example: Channel 1 | ||||
| CchannelState | 1.3.6.1.4.1.674.10893.1.20.130.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the channel. Possible states: 0: Unknown 1: Ready - The I/O has resumed. 2: Failed 3: Online 4: Offline - The I/O has paused. 6: Degraded
| ||||
| CchannelSeverity | 1.3.6.1.4.1.674.10893.1.20.130.2.1.4 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CchannelTermination | 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type of SCSI termination on this channel. Termination is required for proper operation of this channel. 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated
| ||||
| CchannelSCSIID | 1.3.6.1.4.1.674.10893.1.20.130.2.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The SCSI ID of the controller to which the channel belongs. | ||||
| CchannelRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.2.1.7 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the channel state. This is the combined status of the channel and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CchannelComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the channel itself with out without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CchannelNexusID | 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this channel. | ||||
| CchannelDataRate | 1.3.6.1.4.1.674.10893.1.20.130.2.1.10 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The data rate (SCSI speed) of the channel. Example: Ultra 320M SCSI | ||||
| CchannelBusType | 1.3.6.1.4.1.674.10893.1.20.130.2.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The bus type of the channel. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: SSA 6: USB 7: SATA 8: SAS 9: PCIe
| ||||
| TenclosureTable | 1.3.6.1.4.1.674.10893.1.20.130.3 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Enclosures. The number of entries is related to number of enclosures discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RenclosureEntry | 1.3.6.1.4.1.674.10893.1.20.130.3.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Enclosure table . A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CenclosureNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of the enclosure entry. | ||||
| CenclosureName | 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The enclosure's name as represented in Storage Management. | ||||
| CenclosureVendor | 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The enclosure's (re)seller's name. | ||||
| CenclosureState | 1.3.6.1.4.1.674.10893.1.20.130.3.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the enclosure (which includes any devices connected to it.) Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded
| ||||
| CenclosureSeverity | 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CenclosureID | 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Represents unique id for an enclosure. | ||||
| CenclosureProcessorVersion | 1.3.6.1.4.1.674.10893.1.20.130.3.1.7 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. | ||||
| CenclosureServiceTag | 1.3.6.1.4.1.674.10893.1.20.130.3.1.8 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Enclosure identification used when consulting customer support. | ||||
| CenclosureAssetTag | 1.3.6.1.4.1.674.10893.1.20.130.3.1.9 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory User definable asset tag for the enclosure. | ||||
| CenclosureAssetName | 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory User definable asset name of the enclosure. | ||||
| CenclosureSplitBusPartNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.11 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The enclosure's split bus part number. | ||||
| CenclosureProductID | 1.3.6.1.4.1.674.10893.1.20.130.3.1.12 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The enclosure's product identification. This also corresponds to the enclosure type. | ||||
| CenclosureKernelVersion | 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. Refer to enclosureFirmwareVersion for the firmware version of the enclosure. | ||||
| CenclosureESM1PartNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.14 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. | ||||
| CenclosureESM2PartNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.15 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. | ||||
| CenclosureType | 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type of this enclosure. Possible values: 1: Internal 2: Dell PV200S (PV201S) 3: Dell PV210S (PV211S) 4: Dell PV220S (PV221S) 5: Dell PV660F 6: Dell PV224F 7: Dell PV660F / PV224F 8: Dell MD1000 9: Dell MD1120 11: Dell MD1220 12: Dell MD1400 13: Dell MD1420 14: Dell MX5016S
| ||||
| CenclosureProcessor2Version | 1.3.6.1.4.1.674.10893.1.20.130.3.1.17 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory This entry is obsolete for Storage Management. | ||||
| CenclosureConfig | 1.3.6.1.4.1.674.10893.1.20.130.3.1.18 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current configuration of the enclosure's backplane. Possible values: 1: Joined 2: Split Bus 3: Clustered 4: Unified
| ||||
| CenclosureChannelNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The channel number, or bus, to which the enclosure is connected. | ||||
| CenclosureAlarm | 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current status of the enclosure's alarm (PV220S, and PV221S only.) Possible values: 1: Disabled 2: Enabled
| ||||
| CenclosureBackplanePartNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The part number of the enclosure's backplane. | ||||
| CenclosureSCSIID | 1.3.6.1.4.1.674.10893.1.20.130.3.1.22 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The SCSI ID of the controller to which this enclosure is attached. | ||||
| CenclosureRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.3.1.23 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the enclosure state. This is the combined status of the enclosure and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CenclosureComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CenclosureNexusID | 1.3.6.1.4.1.674.10893.1.20.130.3.1.25 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this enclosure. | ||||
| CenclosureFirmwareVersion | 1.3.6.1.4.1.674.10893.1.20.130.3.1.26 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The firmware version of the enclosure. | ||||
| CenclosureSCSIRate | 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Actual SCSI rate in the enclosure. | ||||
| CenclosurePartNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The part number of the enclosure. | ||||
| CenclosureSerialNumber | 1.3.6.1.4.1.674.10893.1.20.130.3.1.29 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Serial number of the enclosure. | ||||
| CenclosureSASAddress | 1.3.6.1.4.1.674.10893.1.20.130.3.1.30 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The specified SAS address if this is a SAS enclosure. | ||||
| CenclosureOccupiedSlotCount | 1.3.6.1.4.1.674.10893.1.20.130.3.1.31 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Shows the number of physical disk slots occupied in a storage enclosure. Note: A value of 9999 indicates feature not available. | ||||
| CenclosureTotalSlots | 1.3.6.1.4.1.674.10893.1.20.130.3.1.32 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Shows the total number of physical slots in a storage enclosure; it includes total count of occupied and empty slots. Note: A value of 9999 indicates feature not available. | ||||
| CenclosureEmptySlotCount | 1.3.6.1.4.1.674.10893.1.20.130.3.1.33 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Shows the number of empty physical disk slots in a storage enclosure. Note: A value of 9999 indicates feature not available. | ||||
| CenclosureExpressServiceCode | 1.3.6.1.4.1.674.10893.1.20.130.3.1.34 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Express Service Code (ESC) is base10 converted numerical value of service tag. | ||||
| TarrayDiskTable | 1.3.6.1.4.1.674.10893.1.20.130.4 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Array Disks. The number of entries is related to number of Array Disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RarrayDiskEntry | 1.3.6.1.4.1.674.10893.1.20.130.4.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Array Disk table . A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CarrayDiskNumber | 1.3.6.1.4.1.674.10893.1.20.130.4.1.1 | INTEGER (1..1000000000) | RO | mandatory |
column · INTEGER (1..1000000000) · read-only · mandatory Instance number of this array disk entry. | ||||
| CarrayDiskName | 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the array disk as represented in Storage Management. | ||||
| CarrayDiskVendor | 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The array disk's manufacturer's name. | ||||
| CarrayDiskState | 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 7: Recovering - Refers to state of recovering from bad blocks on disks. 11: Removed - Indicates that array disk has been removed. 13: Non-RAID - Indicates that array disk is not a RAID capable disk 14: Not Ready - Applicable for PCIeSSD devices indicating that the device is in locked state 15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 22: Replacing - Indicates copyback operation is in progress. 23: Spinning Down - Transit state when the physical disk is spinning down for physical disk power management. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 27: Unusable - INIT error drive 28: Diagnostics - Diagnostics are running. 34: Predictive failure 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 39: Foreign 40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state
| ||||
| CarrayDiskSeverity | 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CarrayDiskProductID | 1.3.6.1.4.1.674.10893.1.20.130.4.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The model number of the array disk. | ||||
| CarrayDiskSerialNo | 1.3.6.1.4.1.674.10893.1.20.130.4.1.7 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The array disk's unique identification number from the manufacturer. | ||||
| CarrayDiskRevision | 1.3.6.1.4.1.674.10893.1.20.130.4.1.8 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The firmware version of the array disk. | ||||
| CarrayDiskEnclosureID | 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The SCSI ID of the enclosure processor to which this array disk belongs. | ||||
| CarrayDiskChannel | 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The bus to which this array disk is connected. | ||||
| CarrayDiskLengthInMB | 1.3.6.1.4.1.674.10893.1.20.130.4.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size in megabytes of the array disk. If this size is 0, it is smaller than a megabyte. | ||||
| CarrayDiskLengthInBytes | 1.3.6.1.4.1.674.10893.1.20.130.4.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size of the array disk in bytes that is less than a megabyte. This size plus the arrayDiskLengthInMB is the total size of the array disk. | ||||
| CarrayDiskLargestContiguousFreeSpaceInMB | 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. | ||||
| CarrayDiskLargestContiguousFreeSpaceInBytes | 1.3.6.1.4.1.674.10893.1.20.130.4.1.14 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte. This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk. | ||||
| CarrayDiskTargetID | 1.3.6.1.4.1.674.10893.1.20.130.4.1.15 | INTEGER (0..15) | RO | mandatory |
column · INTEGER (0..15) · read-only · mandatory The SCSI target ID which this array disk is assigned. | ||||
| CarrayDiskLunID | 1.3.6.1.4.1.674.10893.1.20.130.4.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The array disk's logical unit number. | ||||
| CarrayDiskUsedSpaceInMB | 1.3.6.1.4.1.674.10893.1.20.130.4.1.17 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The amount in megabytes of the used space on the array disk. If this size is 0, it is smaller than a megabyte. | ||||
| CarrayDiskUsedSpaceInBytes | 1.3.6.1.4.1.674.10893.1.20.130.4.1.18 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB is the total amount of used space on the array disk. | ||||
| CarrayDiskFreeSpaceInMB | 1.3.6.1.4.1.674.10893.1.20.130.4.1.19 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The amount in megabytes of the free space on the array disk. If this size is 0, it is smaller than a megabyte. | ||||
| CarrayDiskFreeSpaceInBytes | 1.3.6.1.4.1.674.10893.1.20.130.4.1.20 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size in bytes of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk. | ||||
| CarrayDiskBusType | 1.3.6.1.4.1.674.10893.1.20.130.4.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The bus type of the array disk. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: SSA 6: USB 7: SATA 8: SAS 9: PCIe
| ||||
| CarrayDiskSpareState | 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The status of the array disk as a spare. Possible states: 1 : disk is a member of a virtual disk 2 : disk is a member of a disk group 3 : disk is a global hot spare 4 : disk is a dedicated hot spare 5 : not a spare 99: not applicable
| ||||
| CarrayDiskRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.4.1.23 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the array disk state. This is the combined status of the array disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CarrayDiskComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.4.1.24 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the array disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CarrayDiskDeviceName | 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The operating system device name for this disk. This property is only applicable to array disks attached to a RAID controller. | ||||
| CarrayDiskNexusID | 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this array disk. | ||||
| CarrayDiskPartNumber | 1.3.6.1.4.1.674.10893.1.20.130.4.1.27 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The part number of the disk. | ||||
| CarrayDiskSASAddress | 1.3.6.1.4.1.674.10893.1.20.130.4.1.28 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The specified SAS address if this is a SAS disk. | ||||
| CarrayDiskNegotiatedSpeed | 1.3.6.1.4.1.674.10893.1.20.130.4.1.29 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The speed at which the drive is actually running in MPS (megabytes per second). | ||||
| CarrayDiskCapableSpeed | 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). | ||||
| CarrayDiskSmartAlertIndication | 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicated whether the disk has received a predictive failure. Possible values: 1: No - disk has not received a predictive failure alert 2: Yes - disk has received a predictive failure alert
| ||||
| CarrayDiskManufactureDay | 1.3.6.1.4.1.674.10893.1.20.130.4.1.32 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The day of the week (1=Sunday thru 7=Saturday) on which this disk was manufactured. | ||||
| CarrayDiskManufactureWeek | 1.3.6.1.4.1.674.10893.1.20.130.4.1.33 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The week (1 thru 53) in which this disk was manufactured. | ||||
| CarrayDiskManufactureYear | 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The four digit year in which this disk was manufactured. | ||||
| CarrayDiskMediaType | 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Media type of the array disk. Possible Values: 1:unknown 2:hdd 3:ssd
| ||||
| CarrayDiskDellCertified | 1.3.6.1.4.1.674.10893.1.20.130.4.1.36 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if array disk is certified by Dell. Value: 1 - Certified, 0 - Not Certified, 99 - Unknown | ||||
| CarrayDiskAltaVendorId | 1.3.6.1.4.1.674.10893.1.20.130.4.1.37 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete Provides vendor information for Alta interposer. | ||||
| CarrayDiskAltaProductId | 1.3.6.1.4.1.674.10893.1.20.130.4.1.38 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete Provides product id for Alta interposer. | ||||
| CarrayDiskAltaRevisionId | 1.3.6.1.4.1.674.10893.1.20.130.4.1.39 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete Provides revision id for Alta interposer. | ||||
| CarrayDiskEncryptionCapable | 1.3.6.1.4.1.674.10893.1.20.130.4.1.40 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if physical disk is Encryption capable. Value: 1 - Capable, 0 - Not Capable, 99 - Not Applicable | ||||
| CarrayDiskEncrypted | 1.3.6.1.4.1.674.10893.1.20.130.4.1.41 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if the physical disk has encryption enabled. Value: 1 - Yes, 0 - No, 99 - Not Applicable | ||||
| CarrayDiskPowerState | 1.3.6.1.4.1.674.10893.1.20.130.4.1.42 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates power state of a physical drive. Value: 0 - Spun up, 1- Spun down, 255 - Transition, 99 - Not Applicable | ||||
| CarrayDiskDriveWriteCache | 1.3.6.1.4.1.674.10893.1.20.130.4.1.43 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined/Not Applicable | ||||
| CarrayDiskModelNumber | 1.3.6.1.4.1.674.10893.1.20.130.4.1.44 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Provides PCIe SSD device model number. | ||||
| CarrayDiskLifeRemaining | 1.3.6.1.4.1.674.10893.1.20.130.4.1.45 | INTEGER (0..100) | RO | mandatory |
column · INTEGER (0..100) · read-only · mandatory Provides PCIe SSD device life remaining in percentage. Value: 0..100, 999 - Undetermined/Not Applicable | ||||
| CarrayDiskDriverVersion | 1.3.6.1.4.1.674.10893.1.20.130.4.1.46 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Provides PCIe SSD device driver version. | ||||
| CarrayDiskDeviceLifeStatus | 1.3.6.1.4.1.674.10893.1.20.130.4.1.47 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Provides PCIe SSD device life status. Possible Values: -1: Not Available / Not Applicable 1: Drive Health Good 2: Approaching Warranty Coverage Expiry 3: Warranty Coverage Expired 4: Approaching Read Only 5: Read Only | ||||
| CarrayDiskReadOnly | 1.3.6.1.4.1.674.10893.1.20.130.4.1.48 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Provides PCIe SSD's Read Only attribute. Possible Values: Yes, No, Not Applicable | ||||
| CarrayDiskRemainingRatedWriteEndurance | 1.3.6.1.4.1.674.10893.1.20.130.4.1.49 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Provides PCIe SSD device Remaining Rated Write Endurance Possible Values: 0-100% ,Not Available/Not Applicable | ||||
| CarrayDiskSectorSize | 1.3.6.1.4.1.674.10893.1.20.130.4.1.50 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Provides the information regarding sector size of array disk. Possible values are: 512 or 4096. | ||||
| CarrayDiskPICapable | 1.3.6.1.4.1.674.10893.1.20.130.4.1.51 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Provides the information regarding T10 PI capability of Array disk. Possible values are: 0 (T10 PI incapable) or 1 (T10 PI capable). | ||||
| CarrayDiskMaxLinkWidth | 1.3.6.1.4.1.674.10893.1.20.130.4.1.52 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Provides the information regarding Max Link Width of Array disk. Possible values are: 0 - 8. | ||||
| CarrayDiskNegotiatedLinkWidth | 1.3.6.1.4.1.674.10893.1.20.130.4.1.53 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Provides the information regarding Negtioated Link Width of Array disk. Possible values are: 0 - 8. | ||||
| CnonRAIDdiskCachePolicy | 1.3.6.1.4.1.674.10893.1.20.130.4.1.54 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Displays the current disk write cache policy of the NonRAID disk. Possible values are: Enabled - Disabled. | ||||
| CarraydiskCachePolicy | 1.3.6.1.4.1.674.10893.1.20.130.4.1.55 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Displays the current disk write cache policy of the array disk. Possible values are: Enabled - Disabled - Default. | ||||
| CarraydiskISECapable | 1.3.6.1.4.1.674.10893.1.20.130.4.1.56 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory A boolean value depicitng if the disk is Instant Secure Erase Capable or not. | ||||
| CarraydiskWWN | 1.3.6.1.4.1.674.10893.1.20.130.4.1.57 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Displays WWN for a disk. | ||||
| CarraydiskEncryptionProtocol | 1.3.6.1.4.1.674.10893.1.20.130.4.1.58 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Displays Encrption Protocol for a disk. Possible Values: 0: No encryption 1: TCG Enterprise SSC 2: TCG Opal SSC | ||||
| CarraydiskErrorRecoverable | 1.3.6.1.4.1.674.10893.1.20.130.4.1.59 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if INIT error drive is recoverable. Values: 1- Yes, 0 - No, 99 - Not available / Not applicable. | ||||
| CarraydiskErrorDescription | 1.3.6.1.4.1.674.10893.1.20.130.4.1.60 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Displays description of INIT error. | ||||
| CarraydiskAvailableSpare | 1.3.6.1.4.1.674.10893.1.20.130.4.1.61 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Displays Available Spare for a PCIe SSD. Possible Values: 0-100 % Note: A value of 9999 indicates Not Applicable or Not Available | ||||
| TarrayDiskEnclosureConnectionTable | 1.3.6.1.4.1.674.10893.1.20.130.5 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between array disks, their enclosure, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. Note: Only array disks that are part of an enclosure will be listed in this table. Backplanes are considered enclosures by Storage Management. | ||||
| RarrayDiskEnclosureConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.130.5.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Array Disk Enclosure Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CarrayDiskEnclosureConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.130.5.1.1 | INTEGER (1..1000000000) | RO | mandatory |
column · INTEGER (1..1000000000) · read-only · mandatory Instance number of this array disk connection entry. This table shows the array disk to enclosure relationship. | ||||
| CarrayDiskEnclosureConnectionArrayDiskName | 1.3.6.1.4.1.674.10893.1.20.130.5.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the array disk in this connection as represented in Storage Management. | ||||
| CarrayDiskEnclosureConnectionArrayDiskNumber | 1.3.6.1.4.1.674.10893.1.20.130.5.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the array disk in the arrayDiskTable in this connection. | ||||
| CarrayDiskEnclosureConnectionEnclosureName | 1.3.6.1.4.1.674.10893.1.20.130.5.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the enclosure as represented in Storage Management to which this array disk belongs. | ||||
| CarrayDiskEnclosureConnectionEnclosureNumber | 1.3.6.1.4.1.674.10893.1.20.130.5.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number in the enclosureTable of the enclosure to which this array disk belongs. | ||||
| CarrayDiskEnclosureConnectionControllerName | 1.3.6.1.4.1.674.10893.1.20.130.5.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the controller as represented in Storage Management to which this array disk is connected. | ||||
| CarrayDiskEnclosureConnectionControllerNumber | 1.3.6.1.4.1.674.10893.1.20.130.5.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number in the controllerTable of the controller to which this array disk is connected. | ||||
| TarrayDiskChannelConnectionTable | 1.3.6.1.4.1.674.10893.1.20.130.6 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between array disks, their channel, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. Note: Only array disks that are NOT part of an enclosure will be listed in this table. Backplanes are considered enclosures by Storage Management. | ||||
| RarrayDiskChannelConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.130.6.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Array Disk Channel Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CarrayDiskChannelConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.130.6.1.1 | INTEGER (1..1000000000) | RO | mandatory |
column · INTEGER (1..1000000000) · read-only · mandatory Instance number of this array disk connection entry. This table shows the array disk to SCSI channel relationship. There is no enclosure service processor associated with these array disks. | ||||
| CarrayDiskChannelConnectionArrayDiskName | 1.3.6.1.4.1.674.10893.1.20.130.6.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the array disk in this connection as represented in Storage Management. | ||||
| CarrayDiskChannelConnectionArrayDiskNumber | 1.3.6.1.4.1.674.10893.1.20.130.6.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the array disk in the arrayDiskTable in this connection. | ||||
| CarrayDiskChannelConnectionChannelName | 1.3.6.1.4.1.674.10893.1.20.130.6.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the channel as represented in Storage Management to which is array disk is connected. | ||||
| CarrayDiskChannelConnectionChannelNumber | 1.3.6.1.4.1.674.10893.1.20.130.6.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the channel in the channelTable to which this array disk is connected. | ||||
| CarrayDiskChannelConnectionControllerName | 1.3.6.1.4.1.674.10893.1.20.130.6.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the controller as represented in Storage Management to which this array disk is connected. | ||||
| CarrayDiskChannelConnectionControllerNumber | 1.3.6.1.4.1.674.10893.1.20.130.6.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number in the controllerTable of the controller to which this array disk is connected. | ||||
| TfanTable | 1.3.6.1.4.1.674.10893.1.20.130.7 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Fans. The number of entries is related to number of Fans discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RfanEntry | 1.3.6.1.4.1.674.10893.1.20.130.7.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Fan table . A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CfanNumber | 1.3.6.1.4.1.674.10893.1.20.130.7.1.1 | INTEGER (1..1000000000) | RO | mandatory |
column · INTEGER (1..1000000000) · read-only · mandatory Instance number of this fan entry. | ||||
| CfanName | 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The fan's name as represented in Storage Management. | ||||
| CfanVendor | 1.3.6.1.4.1.674.10893.1.20.130.7.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The fan's (re)seller's name. | ||||
| CfanState | 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing
| ||||
| CfanSeverity | 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CfanProbeUnit | 1.3.6.1.4.1.674.10893.1.20.130.7.1.6 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete for Storage Management. | ||||
| CfanProbeMinWarning | 1.3.6.1.4.1.674.10893.1.20.130.7.1.7 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. This setting is not supported by fans managed under Storage Management. | ||||
| CfanProbeMinCritical | 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. This setting is not supported by fans managed under Storage Management. | ||||
| CfanProbeMaxWarning | 1.3.6.1.4.1.674.10893.1.20.130.7.1.9 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. This setting is not supported by fans managed under Storage Management. | ||||
| CfanProbeMaxCritical | 1.3.6.1.4.1.674.10893.1.20.130.7.1.10 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. This setting is not supported by fans managed under Storage Management. | ||||
| CfanProbeCurrValue | 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The current speed of the fan. | ||||
| Cfan1PartNumber | 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The part number of the fan in the enclosure. | ||||
| Cfan2PartNumber | 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. This setting is not supported by fans managed under Storage Management. | ||||
| CfanRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the fan state. This is the combined status of the fan and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CfanComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.7.1.15 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CfanNexusID | 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this fan. | ||||
| CfanRevision | 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The revision number of the fan in the enclosure. | ||||
| TfanConnectionTable | 1.3.6.1.4.1.674.10893.1.20.130.8 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between each fan on the managed node and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. | ||||
| RfanConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.130.8.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Fan Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CfanConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this fan connection entry. | ||||
| CfanConnectionFanName | 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the fan in this connection as represented in Storage Management. | ||||
| CfanConnectionFanNumber | 1.3.6.1.4.1.674.10893.1.20.130.8.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the fan in the fanTable in this connection. | ||||
| CfanConnectionEnclosureName | 1.3.6.1.4.1.674.10893.1.20.130.8.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the enclosure as represented in Storage Management to which this fan belongs. | ||||
| CfanConnectionEnclosureNumber | 1.3.6.1.4.1.674.10893.1.20.130.8.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the enclosure in the enclosureTable to which this fan belongs. | ||||
| TpowerSupplyTable | 1.3.6.1.4.1.674.10893.1.20.130.9 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Power Supplies. The number of entries is related to number of Power Supplies discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RpowerSupplyEntry | 1.3.6.1.4.1.674.10893.1.20.130.9.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Power Supply table . A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CpowerSupplyNumber | 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this power supply entry. | ||||
| CpowerSupplyName | 1.3.6.1.4.1.674.10893.1.20.130.9.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The power supply's name as represented in Storage Management. | ||||
| CpowerSupplyVendor | 1.3.6.1.4.1.674.10893.1.20.130.9.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The power supply's (re)seller's name. | ||||
| CpowerSupplyState | 1.3.6.1.4.1.674.10893.1.20.130.9.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the power supply. Possible states: 0 : Unknown 1 : Ready 2 : Failed 5 : Not Installed 6 : Degraded 11: Removed 21: Missing
| ||||
| CpowerSupplySeverity | 1.3.6.1.4.1.674.10893.1.20.130.9.1.5 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CpowerSupply1PartNumber | 1.3.6.1.4.1.674.10893.1.20.130.9.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The part number of the power supply of the enclosure. | ||||
| CpowerSupply2PartNumber | 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 | DisplayString | RO | obsolete |
column · DisplayString · read-only · obsolete This entry is obsolete. This setting is not supported by power supplies managed under Storage Management. | ||||
| CpowerSupplyRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.9.1.8 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CpowerSupplyComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the power supply itself without the propegation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CpowerSupplyNexusID | 1.3.6.1.4.1.674.10893.1.20.130.9.1.10 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this power supply. | ||||
| CpowerSupplyRevision | 1.3.6.1.4.1.674.10893.1.20.130.9.1.11 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The revision number of the power supply in the enclosure. | ||||
| TpowerSupplyConnectionTable | 1.3.6.1.4.1.674.10893.1.20.130.10 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between each power supply on the managed node and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. | ||||
| RpowerSupplyConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.130.10.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Power Supply Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CpowerSupplyConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.130.10.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this power supply connection entry. | ||||
| CpowerSupplyConnectionPowersupplyName | 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the power supply in this connection as represented in Storage Management. | ||||
| CpowerSupplyConnectionPowersupplyNumber | 1.3.6.1.4.1.674.10893.1.20.130.10.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This instance number in the powersupplyTable of the power supply in this connection. | ||||
| CpowerSupplyConnectionEnclosureName | 1.3.6.1.4.1.674.10893.1.20.130.10.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the enclosure to which this power supply is connected as represented in Storage Management. | ||||
| CpowerSupplyConnectionEnclosureNumber | 1.3.6.1.4.1.674.10893.1.20.130.10.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the enclosure in the enclosureTable to which this power supply is connected. | ||||
| CpowerSupplyConnectionFirmwareVersion | 1.3.6.1.4.1.674.10893.1.20.130.10.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Displays power supply connection firmware version. Note: Available above 1.04 firmware version | ||||
| TtemperatureProbeTable | 1.3.6.1.4.1.674.10893.1.20.130.11 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Temperature Probes. The number of entries is related to number of Temperature Probes discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RtemperatureProbeEntry | 1.3.6.1.4.1.674.10893.1.20.130.11.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Temperature Probe table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CtemperatureProbeNumber | 1.3.6.1.4.1.674.10893.1.20.130.11.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this temperature probe entry. | ||||
| CtemperatureProbeName | 1.3.6.1.4.1.674.10893.1.20.130.11.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Name of this temperature probe as represented in Storage Management. | ||||
| CtemperatureProbeVendor | 1.3.6.1.4.1.674.10893.1.20.130.11.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Temperature probe's (re)seller's name. | ||||
| CtemperatureProbeState | 1.3.6.1.4.1.674.10893.1.20.130.11.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the temperature probe.
Possible states:
0: Unknown
1: Ready
2: Failed (Minimum Failure Threshold Exceeded,
Maximum Failure Threshold Exceeded)
4: Offline
6: Degraded (Minimum Warning Threshold Exceeded,
Maximum Warning Threshold Exceeded)
9: Inactive
21: Missing
| ||||
| CtemperatureProbeSeverity | 1.3.6.1.4.1.674.10893.1.20.130.11.1.5 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CtemperatureProbeUnit | 1.3.6.1.4.1.674.10893.1.20.130.11.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The units that will be used to display temperatures for this temperature probe. | ||||
| CtemperatureProbeMinWarning | 1.3.6.1.4.1.674.10893.1.20.130.11.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The minimum temperature that will force the probe into a warning state. | ||||
| CtemperatureProbeMinCritical | 1.3.6.1.4.1.674.10893.1.20.130.11.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The minimum temperature that will force the probe into an error state. | ||||
| CtemperatureProbeMaxWarning | 1.3.6.1.4.1.674.10893.1.20.130.11.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum temperature that will force the probe into a warning state. | ||||
| CtemperatureProbeMaxCritical | 1.3.6.1.4.1.674.10893.1.20.130.11.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum temperature that will force the probe into an error state. | ||||
| CtemperatureProbeCurValue | 1.3.6.1.4.1.674.10893.1.20.130.11.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current temperature of this probe. | ||||
| CtemperatureProbeRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.11.1.12 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the temperature probe state. This is the combined status of the temperature probe and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CtemperatureProbeComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.11.1.13 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the temperature probe itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CtemperatureProbeNexusID | 1.3.6.1.4.1.674.10893.1.20.130.11.1.14 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this temperature probe. | ||||
| TtemperatureConnectionTable | 1.3.6.1.4.1.674.10893.1.20.130.12 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between each temperature probe on the managed node and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. | ||||
| RtemperatureConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.130.12.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Temperature Probe Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CtemperatureConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this temperature probe connection entry. | ||||
| CtemperatureConnectionTemperatureName | 1.3.6.1.4.1.674.10893.1.20.130.12.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the temperature probe in this connection as represented in Storage Management. | ||||
| CtemperatureConnectionTemperatureNumber | 1.3.6.1.4.1.674.10893.1.20.130.12.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number in the temperatureTable of the temperature probe in this connection. | ||||
| CtemperatureConnectionEnclosureName | 1.3.6.1.4.1.674.10893.1.20.130.12.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the enclosure as represented in Storage Management to which this temperature probe belongs. | ||||
| CtemperatureConnectionEnclosureNumber | 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the enclosure in the enclosureTable to which this temperature probe belongs. | ||||
| TenclosureManagementModuleTable | 1.3.6.1.4.1.674.10893.1.20.130.13 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Enclosure Management Modules. The number of entries is related to number of Enclosure Management Modules discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RenclosureManagementModuleEntry | 1.3.6.1.4.1.674.10893.1.20.130.13.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Enclosure Management Module table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CenclosureManagementModuleNumber | 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this enclosure memory module entry. | ||||
| CenclosureManagementModuleName | 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Name of this enclosure memory module as represented in Storage Management. | ||||
| CenclosureManagementModuleVendor | 1.3.6.1.4.1.674.10893.1.20.130.13.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The management module's (re)seller's name. | ||||
| CenclosureManagementModuleState | 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing
| ||||
| CenclosureManagementModuleSeverity | 1.3.6.1.4.1.674.10893.1.20.130.13.1.5 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CenclosureManagementModulePartNumber | 1.3.6.1.4.1.674.10893.1.20.130.13.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The part number of the enclosure memory module. | ||||
| CenclosureManagementModuleType | 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The type of the enclosure management module. Possible values: 0: Unknown 1: EMM 2: Termination Card
| ||||
| CenclosureManagementModuleFWVersion | 1.3.6.1.4.1.674.10893.1.20.130.13.1.8 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Firmware version of the enclosure memory module. | ||||
| CenclosureManagementModuleMaxSpeed | 1.3.6.1.4.1.674.10893.1.20.130.13.1.9 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The maximum bus speed of the enclosure management module. | ||||
| CenclosureManagementModuleRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the enclosure management module state. This is the combined status of the EMM and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CenclosureManagementModuleComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.13.1.11 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the enclosure management module itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CenclosureManagementModuleNexusID | 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this EMM. | ||||
| CenclosureManagementModuleRevision | 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The revision number of the enclosure management module. | ||||
| TenclosureManagementModuleConnectionTable | 1.3.6.1.4.1.674.10893.1.20.130.14 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between each enclosure management module on the managed node and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. | ||||
| RenclosureManagementModuleConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.130.14.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Enclosure Management Module Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CenclosureManagementModuleConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.130.14.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this enclosure management module connection entry. | ||||
| CenclosureManagementModuleConnectionEMMName | 1.3.6.1.4.1.674.10893.1.20.130.14.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the enclosure management module in this connection as represented in Storage Management. | ||||
| CenclosureManagementModuleConnectionEMMNumber | 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the enclosure management module in the enclosureManagementModuleTable in this connection. | ||||
| CenclosureManagementModuleConnectionEnclosureName | 1.3.6.1.4.1.674.10893.1.20.130.14.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the enclosure as represented in Storage Management to which this enclosure management module belongs. | ||||
| CenclosureManagementModuleConnectionEnclosureNumber | 1.3.6.1.4.1.674.10893.1.20.130.14.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the enclosure in the enclosureTable to which this enclosure management module belongs. | ||||
| TbatteryTable | 1.3.6.1.4.1.674.10893.1.20.130.15 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Batteries. The number of entries is related to number of Batteries discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RbatteryEntry | 1.3.6.1.4.1.674.10893.1.20.130.15.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Battery table . A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CbatteryNumber | 1.3.6.1.4.1.674.10893.1.20.130.15.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this battery entry. | ||||
| CbatteryName | 1.3.6.1.4.1.674.10893.1.20.130.15.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The battery's name as represented in Storage Management. | ||||
| CbatteryVendor | 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The battery's (re)seller's name. | ||||
| CbatteryState | 1.3.6.1.4.1.674.10893.1.20.130.15.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Current state of battery. Possible values: 0: Unknown 1: Ready 2: Failed 6: Degraded 7: Reconditioning 9: High 10: Low Power 12: Charging 21: Missing 36: Learning
| ||||
| CbatteryRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the battery state. This is the combined status of the battery and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CbatteryComponentStatus | 1.3.6.1.4.1.674.10893.1.20.130.15.1.6 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CbatteryChargeCount | 1.3.6.1.4.1.674.10893.1.20.130.15.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of charges that have been applied to the battery. | ||||
| CbatteryMaxChargeCount | 1.3.6.1.4.1.674.10893.1.20.130.15.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum number of charges that can be applied to the battery. | ||||
| CbatteryNexusID | 1.3.6.1.4.1.674.10893.1.20.130.15.1.9 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this battery. | ||||
| CbatteryPredictedCapacity | 1.3.6.1.4.1.674.10893.1.20.130.15.1.10 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This property displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete.
| ||||
| CbatteryNextLearnTime | 1.3.6.1.4.1.674.10893.1.20.130.15.1.11 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Time next learn cycle must be executed (in hours.) | ||||
| CbatteryLearnState | 1.3.6.1.4.1.674.10893.1.20.130.15.1.12 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated Specifies the learn state activity of the battery. Possible values: 1 : Failed 2 : Active 4 : Timed out 8 : Requested 16: Idle 32: Due
| ||||
| CbatteryID | 1.3.6.1.4.1.674.10893.1.20.130.15.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Represents unique id for battery. | ||||
| CbatteryMaxLearnDelay | 1.3.6.1.4.1.674.10893.1.20.130.15.1.14 | INTEGER | RO | deprecated |
column · INTEGER · read-only · deprecated The maximum amount of time (in hours) that the battery learn cycle can be delayed. | ||||
| CbatteryLearnMode | 1.3.6.1.4.1.674.10893.1.20.130.15.1.15 | INTEGER | RW | deprecated |
column · INTEGER · read-write · deprecated Indicates current learn mode of the battery. Possible values: 1: Auto 2: Warn 4: Autowarn 8: Unknown
| ||||
| TbatteryConnectionTable | 1.3.6.1.4.1.674.10893.1.20.130.16 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between each battery on the managed node and its controller. Each controller number in the table corresponds to that controller instance in the Controller Table. | ||||
| RbatteryConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.130.16.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Battery Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CbatteryConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.130.16.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this battery connection entry. | ||||
| CbatteryConnectionBatteryName | 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the battery in this connection as represented in Storage Management. | ||||
| CbatteryConnectionBatteryNumber | 1.3.6.1.4.1.674.10893.1.20.130.16.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number in the batteryTable of the battery in this connection. | ||||
| CbatteryConnectionControllerName | 1.3.6.1.4.1.674.10893.1.20.130.16.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the controller as represented in Storage Management to which this battery belongs. | ||||
| CbatteryConnectionControllerNumber | 1.3.6.1.4.1.674.10893.1.20.130.16.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the controller in the controllerTable to which this battery belongs. | ||||
| TtapeDriveTable | 1.3.6.1.4.1.674.10893.1.20.130.17 | NA | mandatory | |
table · not-accessible · mandatory A table of listed Tape Drives The number of entries is related to number of Tape Drives discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RtapeDriveEntry | 1.3.6.1.4.1.674.10893.1.20.130.17.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Tape Library table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CtapeDriveNumber | 1.3.6.1.4.1.674.10893.1.20.130.17.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this tape drive entry. | ||||
| CtapeDriveName | 1.3.6.1.4.1.674.10893.1.20.130.17.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the tape drive as represented in Storage Management. | ||||
| CtapeDriveVendor | 1.3.6.1.4.1.674.10893.1.20.130.17.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The tape drive's manufacturer's name. | ||||
| CtapeDriveProductID | 1.3.6.1.4.1.674.10893.1.20.130.17.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The model number of the tape drive | ||||
| CtapeDriveNexusID | 1.3.6.1.4.1.674.10893.1.20.130.17.1.5 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this tape drive | ||||
| CtapeDriveBusType | 1.3.6.1.4.1.674.10893.1.20.130.17.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The bus type of the tape drive. Possible values: 8. SAS
| ||||
| CtapeDriveSASAddress | 1.3.6.1.4.1.674.10893.1.20.130.17.1.7 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The specified SAS address if this is a SAS tape drive. | ||||
| CtapeDriveMediaType | 1.3.6.1.4.1.674.10893.1.20.130.17.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Media type of the tape drive. Possible Values: 4:Tape
| ||||
| TnvmeAdapterTable | 1.3.6.1.4.1.674.10893.1.20.130.18 | NA | mandatory | |
table · not-accessible · mandatory A table of listed NVME Adapter cards. The number of entries is related to number of NVME Adapter cards discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RnvmeAdapterEntry | 1.3.6.1.4.1.674.10893.1.20.130.18.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the NvmeAdapter table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CnvmeAdapterNumber | 1.3.6.1.4.1.674.10893.1.20.130.18.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this NVME Adapter entry. | ||||
| CnvmeAdapterState | 1.3.6.1.4.1.674.10893.1.20.130.18.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current state of the NVMe Adapter. | ||||
| CnvmeAdapterControllerNum | 1.3.6.1.4.1.674.10893.1.20.130.18.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The PCIeSSD subsystem Id to which the NVMe Adapter belongs to. | ||||
| CnvmeAdapterPCISlot | 1.3.6.1.4.1.674.10893.1.20.130.18.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The PCI slot of the system where the adapter card is connected. | ||||
| CnvmeAdapterDeviceName | 1.3.6.1.4.1.674.10893.1.20.130.18.1.5 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The device name of the NVMe Adapter as it is represented in OMSA and also the operating system. | ||||
| CnvmeAdapterVendor | 1.3.6.1.4.1.674.10893.1.20.130.18.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory NVMe Adapter manufacturer. | ||||
| CnvmeAdapterProductID | 1.3.6.1.4.1.674.10893.1.20.130.18.1.7 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The product id or part number of the NVMe Adapter | ||||
| CnvmeAdapterSerialNumber | 1.3.6.1.4.1.674.10893.1.20.130.18.1.8 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Product serial number of the NVMe Adapter. | ||||
| CnvmeAdapterRevision | 1.3.6.1.4.1.674.10893.1.20.130.18.1.9 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The NVMe Adapter revision. | ||||
| CnvmeAdapterDriverVersion | 1.3.6.1.4.1.674.10893.1.20.130.18.1.10 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory NVMe Adapter driver version. | ||||
| CnvmeAdapterPCIBusNo | 1.3.6.1.4.1.674.10893.1.20.130.18.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The PCI Bus number of the NVMe adapter. | ||||
| CnvmeAdapterPCIDeviceNum | 1.3.6.1.4.1.674.10893.1.20.130.18.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The PCI device number of the NVMe Adapter. | ||||
| CnvmeAdapterPCIFuncNum | 1.3.6.1.4.1.674.10893.1.20.130.18.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The PCI device number of the NVMe Adapter. | ||||
| CnvmeAdapterNexusID | 1.3.6.1.4.1.674.10893.1.20.130.18.1.14 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Nexus ID of the NVMe Adapter. | ||||
| CnvmeAdapterBusProtocolType | 1.3.6.1.4.1.674.10893.1.20.130.18.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The Bus protocol for NVMe device, expected value: 9 (PCIeSSD). | ||||
| CnvmeAdapterMediaType | 1.3.6.1.4.1.674.10893.1.20.130.18.1.16 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory NVMe Adapter media type. Possible Values: 1:unknown 2:ssd | ||||
| CnvmeAdapterLengthInMegaBytes | 1.3.6.1.4.1.674.10893.1.20.130.18.1.17 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Size in megabytes of the NVMe Adapter. | ||||
| CnvmeAdapterLengthOffsetBytes | 1.3.6.1.4.1.674.10893.1.20.130.18.1.18 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory No of bytes after total number of megabytes have been subtracted from the total size of the NVMe Adapter. | ||||
| CnvmeAdapterDeviceID | 1.3.6.1.4.1.674.10893.1.20.130.18.1.19 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The device Id of the NVMe Adapter. | ||||
| CnvmeAdapterModelNumber | 1.3.6.1.4.1.674.10893.1.20.130.18.1.20 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Model number of the NVMe Adapter as per the manufacturer. | ||||
| CnvmeAdapterNegotiatedSpeed | 1.3.6.1.4.1.674.10893.1.20.130.18.1.21 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The negotiated speed of the NVMe adapter in GT/s. | ||||
| CnvmeAdapterCapableSpeed | 1.3.6.1.4.1.674.10893.1.20.130.18.1.22 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum rated speed of the NVMe adapter in GT/s. | ||||
| CnvmeAdapterRemainingRatedWrEnd | 1.3.6.1.4.1.674.10893.1.20.130.18.1.23 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The remaining percentage of writes on the NVME device | ||||
| CnvmeAdapterFormFactor | 1.3.6.1.4.1.674.10893.1.20.130.18.1.24 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The form factor of the NVMe Adapter. Expected Value: 2 means (Card) | ||||
| CnvmeAdapterSupportedSpec | 1.3.6.1.4.1.674.10893.1.20.130.18.1.25 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The NVMe specification supported by the device. | ||||
| CnvmeAdapterMaxLinkWidth | 1.3.6.1.4.1.674.10893.1.20.130.18.1.26 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The maximum bus width of NVME Adapter | ||||
| CnvmeAdapterNegotiatedLinkWidth | 1.3.6.1.4.1.674.10893.1.20.130.18.1.27 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The negotiated bus width of NVME Adapter. | ||||
| CnvmeAdapterSubVendor | 1.3.6.1.4.1.674.10893.1.20.130.18.1.28 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Sub vendor of the NVMe Adapter device. | ||||
| CnvmeAdapterAvailableSpare | 1.3.6.1.4.1.674.10893.1.20.130.18.1.29 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The remaining available spare space on the NVME device | ||||
| NlogicalDevices | 1.3.6.1.4.1.674.10893.1.20.140 | |||
| TvirtualDiskTable | 1.3.6.1.4.1.674.10893.1.20.140.1 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Virtual Disks. The number of entries is related to number of Virtual Disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RvirtualDiskEntry | 1.3.6.1.4.1.674.10893.1.20.140.1.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Virtual Disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CvirtualDiskNumber | 1.3.6.1.4.1.674.10893.1.20.140.1.1.1 | INTEGER (1..100000000) | RO | mandatory |
column · INTEGER (1..100000000) · read-only · mandatory Instance number of this virtual disk entry. | ||||
| CvirtualDiskName | 1.3.6.1.4.1.674.10893.1.20.140.1.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The virtual disk's label generated by Storage Management or entered by the user. | ||||
| CvirtualDiskDeviceName | 1.3.6.1.4.1.674.10893.1.20.140.1.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Device name used by this virtual disk's member disks. | ||||
| CvirtualDiskState | 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The current condition of this virtual disk (which includes any member array disks.) Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - Access has been lost to the data or is about to be lost. 3: Online 4: Offline - The disk is not accessible. The disk may be corrupted or intermittently unavailable. 6: Degraded - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 15: Resynching 16: Regenerating 24: Rebuilding 26: Formatting 32: Reconstructing 35: Initializing 36: Background Initialization 38: Resynching Paused 52: Permanently Degraded 54: Degraded Redundancy
| ||||
| CvirtualDiskSeverity | 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
| ||||
| CvirtualDiskLengthInMB | 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte. | ||||
| CvirtualDiskLengthInBytes | 1.3.6.1.4.1.674.10893.1.20.140.1.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The portion of the virtual disk in bytes that is smaller than a megabyte. This size plus the virtualDiskLengthInMB is the total size of the virtual disk. | ||||
| CvirtualDiskFreeSpaceInMB | 1.3.6.1.4.1.674.10893.1.20.140.1.1.8 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. This property is not supported for virtual disks managed under Storage Management. | ||||
| CvirtualDiskFreeSpaceInBytes | 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. This property is not supported for virtual disks managed under Storage Management. | ||||
| CvirtualDiskWritePolicy | 1.3.6.1.4.1.674.10893.1.20.140.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the controller's write cache will be used when writing to a virtual disk. Possible values: 1: Enabled - Adaptec Write Cache Enabled Protected 2: Disabled - Adaptec Write Cache Disabled 3: LSI Write Back 4: LSI Write Through 5: Enabled Always - Adaptec only 6: Force write back 7: Enabled Always - SAS only 9: Not Applicable
| ||||
| CvirtualDiskReadPolicy | 1.3.6.1.4.1.674.10893.1.20.140.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the controller's read cache will be used when reading from a virtual disk. Possible values: 1: Enabled - Adaptec Read Cache Enabled 2: Disabled - Adaptec Read Cache Disabled 3: LSI Read Ahead 4: LSI Adaptive Read Ahead 5: LSI No Read Ahead 9: Not Applicable
| ||||
| CvirtualDiskCachePolicy | 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not applicable
| ||||
| CvirtualDiskLayout | 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The virtual disk's RAID type. Currently supported types: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24: RAID-60 25: CacheCade
| ||||
| CvirtualDiskCurStripeSizeInMB | 1.3.6.1.4.1.674.10893.1.20.140.1.1.14 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The stripe size of this virtual disk in megabytes. If this size is 0, it is either smaller than a megabyte or not applicable. | ||||
| CvirtualDiskCurStripeSizeInBytes | 1.3.6.1.4.1.674.10893.1.20.140.1.1.15 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The portion of the stripe size in bytes that is smaller than a megabyte. This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk. If this size is 0, either the entire size is whole megabytes or it is not applicable. | ||||
| CvirtualDiskChannel | 1.3.6.1.4.1.674.10893.1.20.140.1.1.16 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. | ||||
| CvirtualDiskTargetID | 1.3.6.1.4.1.674.10893.1.20.140.1.1.17 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Unique ID for the virtual disk. | ||||
| CvirtualDiskLunID | 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 | INTEGER | RO | obsolete |
column · INTEGER · read-only · obsolete This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. | ||||
| CvirtualDiskRollUpStatus | 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory Severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CvirtualDiskComponentStatus | 1.3.6.1.4.1.674.10893.1.20.140.1.1.20 | DellStatus | RO | mandatory |
column · DellStatus · read-only · mandatory The status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| CvirtualDiskNexusID | 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this virtual disk. | ||||
| CvirtualDiskArrayDiskType | 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Identifies the type of array (physical) disks used to create the virtual disk. Possible values: 1: SAS 2: SATA 3: SCSI 4: IDE 5: PCIE 99: Unknown
| ||||
| CvirtualDiskBadBlocksDetected | 1.3.6.1.4.1.674.10893.1.20.140.1.1.23 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if virtual disk has bad blocks. Value: 0 - No, 1 - Yes, 2 - Not Applicable, 99 - Unknown | ||||
| CvirtualDiskEncrypted | 1.3.6.1.4.1.674.10893.1.20.140.1.1.24 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if virtual disk is encrypted. Value: 0 - No, 1 - Yes, 99 - Unknown. | ||||
| CvirtualDiskIsCacheCade | 1.3.6.1.4.1.674.10893.1.20.140.1.1.25 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if this virtual disk is configured as CacheCade. Value: 1 - Yes, 0 - No, 99 - Undetermined | ||||
| CvirtualDiskDiskCachePolicy | 1.3.6.1.4.1.674.10893.1.20.140.1.1.26 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates disk cache policy of the logical device. Value: 1 - Unchanged, 2 - Enabled, 4 - Disabled, 8 - Default, 10 - Undetermined
| ||||
| CvirtualDiskAssociatedFluidCacheStatus | 1.3.6.1.4.1.674.10893.1.20.140.1.1.27 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates the status of the associated fluid cache status | ||||
| CvirtualDiskPIEnable | 1.3.6.1.4.1.674.10893.1.20.140.1.1.28 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Indicates if T10 PI is enabled on a virtual disk. Possible values are: 0 (T10 PI disabled) or 1 (T10 PI enabled). | ||||
| TvirtualDiskPartitionTable | 1.3.6.1.4.1.674.10893.1.20.140.2 | NA | mandatory | |
table · not-accessible · mandatory A table of managed Virtual Disk Partitions. The number of entries is related to number of partitions discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RvirtualDiskPartitionEntry | 1.3.6.1.4.1.674.10893.1.20.140.2.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Virtual Disk Partition table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CvirtualDiskPartitionNumber | 1.3.6.1.4.1.674.10893.1.20.140.2.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this partition entry | ||||
| CvirtualDiskPartitionDeviceName | 1.3.6.1.4.1.674.10893.1.20.140.2.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Device name of the partition given by the operating system. | ||||
| CvirtualDiskPartitionState | 1.3.6.1.4.1.674.10893.1.20.140.2.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory State of the partition. This is mapped stated of the associate virtual disk. 1: Active - Mapped cache disk is working fine 2: No - Fluid caching is not enabled 3: Removing - This is a transient stage duing the process of disabling the cache 4: Failed - Mapped cache disk has failed.
| ||||
| CvirtualDiskPartitionSize | 1.3.6.1.4.1.674.10893.1.20.140.2.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Size of the Partition in GB. | ||||
| CvirtualDiskPartitionFluidCacheStatus | 1.3.6.1.4.1.674.10893.1.20.140.2.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates if the partition has associated fluidcache | ||||
| CvirtualDiskPartitionNexusID | 1.3.6.1.4.1.674.10893.1.20.140.2.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Durable unique ID for this partition. This comprises the controllerID, virtualDisk ID and hash mapped WWN number of this partition | ||||
| TarrayDiskLogicalConnectionTable | 1.3.6.1.4.1.674.10893.1.20.140.3 | NA | mandatory | |
table · not-accessible · mandatory A table of the connections between array disks, the virtual disk to which they belong, and their associated logical disk. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. | ||||
| RarrayDiskLogicalConnectionEntry | 1.3.6.1.4.1.674.10893.1.20.140.3.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Array Disk Logical Connection table . A row in this table cannot be created or deleted by SNMP operations on columns of the table. | ||||
| CarrayDiskLogicalConnectionNumber | 1.3.6.1.4.1.674.10893.1.20.140.3.1.1 | INTEGER (1..1000000000) | RO | mandatory |
column · INTEGER (1..1000000000) · read-only · mandatory Instance number of this array disk logical connection entry. | ||||
| CarrayDiskLogicalConnectionArrayDiskName | 1.3.6.1.4.1.674.10893.1.20.140.3.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the array disk in this logical connection. | ||||
| CarrayDiskLogicalConnectionArrayDiskNumber | 1.3.6.1.4.1.674.10893.1.20.140.3.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the array disk in this logical connection. | ||||
| CarrayDiskLogicalConnectionVirtualDiskName | 1.3.6.1.4.1.674.10893.1.20.140.3.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the virtual disk to which this array disk belongs. | ||||
| CarrayDiskLogicalConnectionVirtualDiskNumber | 1.3.6.1.4.1.674.10893.1.20.140.3.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The instance number of the virtual disk to which this array disk belongs. | ||||
| CarrayDiskLogicalConnectionDiskName | 1.3.6.1.4.1.674.10893.1.20.140.3.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The name of the disk group to with this array disk belongs. This property is currently not supported. | ||||
| CarrayDiskLogicalConnectionDiskNumber | 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This instance number of the disk group to with this array disk belongs. This property is currently not supported. | ||||
| TfluidCacheTable | 1.3.6.1.4.1.674.10893.1.20.140.4 | NA | mandatory | |
table · not-accessible · mandatory A table of managed FluidCache. The number of entries is related to FluidCache discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | ||||
| RfluidCacheEntry | 1.3.6.1.4.1.674.10893.1.20.140.4.1 | NA | mandatory | |
row · not-accessible · mandatory An entry in the Fluid Cache table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| ||||
| CfluidCacheNumber | 1.3.6.1.4.1.674.10893.1.20.140.4.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of this fluid cache entry | ||||
| CfluidCacheName | 1.3.6.1.4.1.674.10893.1.20.140.4.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory The name of the fluidcache in this subsystem as represented in Storage Management. | ||||
| CfluidCacheLicenseState | 1.3.6.1.4.1.674.10893.1.20.140.4.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory License state of the associated fluid cache subsystem | ||||
| CfluidCacheLicenseValidity | 1.3.6.1.4.1.674.10893.1.20.140.4.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This entry displays the number of days the fluid cache license is valid. It has to be read in parallel to license type. Incase of site wide license, value '0' should be read as 'Not Applicable' | ||||
| CfluidCacheLicenseEntitlementID | 1.3.6.1.4.1.674.10893.1.20.140.4.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indiactes the Entitlement Identifier for the license of the fluid cache subsystem | ||||
| CfluidCacheLicenseDuration | 1.3.6.1.4.1.674.10893.1.20.140.4.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the duration of the the license validity | ||||
| CfluidCacheLicenseCapacity | 1.3.6.1.4.1.674.10893.1.20.140.4.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the capacity of the license of fluidcache subsystem | ||||
| CfluidCacheLicenseRemaining | 1.3.6.1.4.1.674.10893.1.20.140.4.1.8 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Indicates the remaining days of the license validity | ||||
| CfluidCacheLicenseType | 1.3.6.1.4.1.674.10893.1.20.140.4.1.9 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the type of the license of the fluidcache subsystem | ||||
| CfluidCacheLicenseVendor | 1.3.6.1.4.1.674.10893.1.20.140.4.1.10 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the license vendor for the fluidcache subsystem | ||||
| CfluidCacheLicenseProductId | 1.3.6.1.4.1.674.10893.1.20.140.4.1.11 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the product ID of the license of the fluidcache susbsytem | ||||
| CfluidCacheLicenseDateSold | 1.3.6.1.4.1.674.10893.1.20.140.4.1.12 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the date on which the license for the fluidcache subsystem is sold | ||||
| CfluidCacheLicenseGeneration | 1.3.6.1.4.1.674.10893.1.20.140.4.1.13 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the generation of the license for the fluidcache subsystem | ||||
| CfluidCacheLicenseFeatureID | 1.3.6.1.4.1.674.10893.1.20.140.4.1.14 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the license feature ID of the fluidcache subsystem | ||||
| CfluidCacheLicenseFeatureDescription | 1.3.6.1.4.1.674.10893.1.20.140.4.1.15 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Provides the description of the license feature of fluidcache subsystem | ||||
| CfluidCacheNexus | 1.3.6.1.4.1.674.10893.1.20.140.4.1.16 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates the unique ID of the fludicache component | ||||
| TfluidCacheDiskTable | 1.3.6.1.4.1.674.10893.1.20.140.5 | NA | mandatory | |
table · not-accessible · mandatory Indicates the Disk Table of the fludicache component | ||||
| RfluidCacheDiskEntry | 1.3.6.1.4.1.674.10893.1.20.140.5.1 | NA | mandatory | |
row · not-accessible · mandatory Indicates the Disk Number of the fludicache component
| ||||
| CfluidCacheDiskNumber | 1.3.6.1.4.1.674.10893.1.20.140.5.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of the fluidCacheDisk entry | ||||
| CfluidCacheDiskName | 1.3.6.1.4.1.674.10893.1.20.140.5.1.2 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Name of the Fluid Cache Disk Name as seen by storage management | ||||
| CfluidCacheDiskState | 1.3.6.1.4.1.674.10893.1.20.140.5.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory State of the FluidCacheDisk entry Valid values are 2 - Active, otherwise Inactive | ||||
| CfluidCacheDiskBackendDeviceType | 1.3.6.1.4.1.674.10893.1.20.140.5.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory This displays the type of the backend device beneath the fluid cache disk. Values are as below 773 denotes VirtualDisk 791 denotes Partition | ||||
| CfluidCacheDiskBackendDeviceName | 1.3.6.1.4.1.674.10893.1.20.140.5.1.5 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Device name of the backend device as seen by the operating system | ||||
| CfluidCacheDiskBackendDeviceSize | 1.3.6.1.4.1.674.10893.1.20.140.5.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Size of the Backend device. Size is indicated in GB | ||||
| CfluidCacheDiskOperatingMode | 1.3.6.1.4.1.674.10893.1.20.140.5.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Operating mode of the FluidCache. Values are 0 - Writeback mode 1 - Writethrough mode 2 - PassThrough mode | ||||
| CfluidCacheDiskConfiguredMode | 1.3.6.1.4.1.674.10893.1.20.140.5.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Configured Mode of the FluidCache. The values are 0 - Writeback mode 1 - Writethrough mode 2 - PassThrough mode | ||||
| CfluidCacheDiskNexus | 1.3.6.1.4.1.674.10893.1.20.140.5.1.9 | OCTET STRING | RW | mandatory |
column · OCTET STRING · read-write · mandatory Durable Unique ID of the fluidcache disk | ||||
| CfluidCacheDiskStatus | 1.3.6.1.4.1.674.10893.1.20.140.5.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Severity of the fluid cache disk state. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| TfluidCachePoolTable | 1.3.6.1.4.1.674.10893.1.20.140.6 | NA | mandatory | |
table · not-accessible · mandatory Indicates the Pool Table of the fludicache component | ||||
| RfluidCachePoolEntry | 1.3.6.1.4.1.674.10893.1.20.140.6.1 | NA | mandatory | |
row · not-accessible · mandatory Indicates the Pool Number of the fludicache component
| ||||
| CfluidCachePoolNumber | 1.3.6.1.4.1.674.10893.1.20.140.6.1.1 | INTEGER (1..255) | RO | mandatory |
column · INTEGER (1..255) · read-only · mandatory Instance number of the fluid cachepool entry | ||||
| CfluidCachePoolStoreCount | 1.3.6.1.4.1.674.10893.1.20.140.6.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Number of flash devices that are part of the fluidcache pool | ||||
| CfluidCachePoolUUID | 1.3.6.1.4.1.674.10893.1.20.140.6.1.3 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory UUID of the fluidcache pool | ||||
| CfluidCachePoolLicenseState | 1.3.6.1.4.1.674.10893.1.20.140.6.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory State of the fluid cache license. Possible values: Valid, Evaluation, Expired | ||||
| CfluidCachePoolSize | 1.3.6.1.4.1.674.10893.1.20.140.6.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Size of the fluidcache pool in GiB | ||||
| CfluidCachePoolHighAvailabilityState | 1.3.6.1.4.1.674.10893.1.20.140.6.1.6 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Indicates if the fluidcache pool is operating in high availability mode. | ||||
| CfluidCachePoolNexus | 1.3.6.1.4.1.674.10893.1.20.140.6.1.7 | OCTET STRING | RO | mandatory |
column · OCTET STRING · read-only · mandatory Durable unique ID of the fluidcache pool entry | ||||
| CfluidCachePoolStatus | 1.3.6.1.4.1.674.10893.1.20.140.6.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Severity of the fluid cache pool table state. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | ||||
| NstorageManagementEvent | 1.3.6.1.4.1.674.10893.1.20.200 | |||
| !alertStorageManagementInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.101 | |||
notification Storage Management Information There is no global status change associated with this trap.
| ||||
| !alertStorageManagementNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.102 | |||
notification There is no global status change associated with this trap.
| ||||
| !alertStorageManagementWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.103 | |||
notification Storage Management has detected a device independent warning condition. There is no global status change associated with this trap.
| ||||
| !alertStorageManagementFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.104 | |||
notification Storage Management has detected a device independent error condition. There is no global status change associated with this trap.
| ||||
| !alertStorageManagementNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.105 | |||
notification Storage Management has detected a device independent non-recoverable condition. There is no global status change associated with this trap.
| ||||
| !alertControllerInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.751 | |||
notification Controller information. | ||||
| !alertControllerNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.752 | |||
notification Controller has returned to normal. | ||||
| !alertControllerWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.753 | |||
notification Controller warning. | ||||
| !alertControllerFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.754 | |||
notification Controller failure. | ||||
| !alertControllerNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.755 | |||
notification Controller is non-recoverable. | ||||
| !alertChannelInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.801 | |||
notification Channel information. | ||||
| !alertChannelNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.802 | |||
notification Channel has returned to normal. | ||||
| !alertChannelWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.803 | |||
notification Channel warning. | ||||
| !alertChannelFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.804 | |||
notification Channel failure. | ||||
| !alertChannelNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.805 | |||
notification Channel is non-recoverable. | ||||
| !alertEnclosureInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.851 | |||
notification Enclosure information. | ||||
| !alertEnclosureNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.852 | |||
notification Enclosure has returned to normal. | ||||
| !alertEnclosureWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.853 | |||
notification Enclosure warning. | ||||
| !alertEnclosureFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.854 | |||
notification Enclosure failure. | ||||
| !alertEnclosureNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.855 | |||
notification Enclosure is non-recoverable. | ||||
| !alertArrayDiskInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.901 | |||
notification Array disk information. | ||||
| !alertArrayDiskNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.902 | |||
notification Array disk has returned to normal. | ||||
| !alertArrayDiskWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.903 | |||
notification Array disk warning. | ||||
| !alertArrayDiskFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.904 | |||
notification Array disk failure. | ||||
| !alertArrayDiskNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.905 | |||
notification Array disk is non-recoverable. | ||||
| !alertEMMInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.951 | |||
notification EMM information. | ||||
| !alertEMMNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.952 | |||
notification EMM has returned to normal. | ||||
| !alertEMMWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.953 | |||
notification EMM warning. | ||||
| !alertEMMFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.954 | |||
notification EMM failure. | ||||
| !alertEMMNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.955 | |||
notification EMM is non-recoverable. | ||||
| !alertPowerSupplyInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1001 | |||
notification Power supply information. | ||||
| !alertPowerSupplyNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.1002 | |||
notification Power supply has returned to normal. | ||||
| !alertPowerSupplyWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1003 | |||
notification Power supply warning. | ||||
| !alertPowerSupplyFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1004 | |||
notification Power supply failure. | ||||
| !alertPowerSupplyNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.1005 | |||
notification Power supply is non-recoverable. | ||||
| !alertTemperatureProbeInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1051 | |||
notification Temperature probe information. | ||||
| !alertTemperatureProbeNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.1052 | |||
notification Temperature probe has returned to normal. | ||||
| !alertTemperatureProbeWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1053 | |||
notification Temperature probe warning. | ||||
| !alertTemperatureProbeFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1054 | |||
notification Temperature probe failure. | ||||
| !alertTemperatureProbeNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.1055 | |||
notification Temperature probe is non-recoverable. | ||||
| !alertFanInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1101 | |||
notification Fan information. | ||||
| !alertFanNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.1102 | |||
notification Fan has returned to normal. | ||||
| !alertFanWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1103 | |||
notification Fan warning. | ||||
| !alertFanFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1104 | |||
notification Fan failure. | ||||
| !alertFanNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.1105 | |||
notification Fan is non-recoverable. | ||||
| !alertBatteryInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1151 | |||
notification Battery information. | ||||
| !alertBatteryNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.1152 | |||
notification Battery has returned to normal. | ||||
| !alertBatteryWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1153 | |||
notification Battery warning. | ||||
| !alertBatteryFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1154 | |||
notification Battery failure. | ||||
| !alertBatteryNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.1155 | |||
notification Battery is non-recoverable. | ||||
| !alertVirtualDiskInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1201 | |||
notification Virtual disk information. | ||||
| !alertVirtualDiskNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.1202 | |||
notification Virtual disk has returned to normal. | ||||
| !alertVirtualDiskWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1203 | |||
notification Virtual disk warning. | ||||
| !alertVirtualDiskFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1204 | |||
notification Virtual disk failure. | ||||
| !alertVirtualDiskNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.1205 | |||
notification Virtual disk is non-recoverable. | ||||
| !alertRedundancyNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.1304 | |||
notification Redundancy has returned to normal. | ||||
| !alertRedundancyDegraded | 1.3.6.1.4.1.674.10893.1.20.200.0.1305 | |||
notification Redundancy has been degraded. | ||||
| !alertRedundancyLost | 1.3.6.1.4.1.674.10893.1.20.200.0.1306 | |||
notification Redundancy has been lost. | ||||
| !alertFluidCacheDiskInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1401 | |||
notification Fluid Cache Disk Information | ||||
| !alertfluidCacheDiskWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1403 | |||
notification Fluid Cache Disk warning. | ||||
| !alertFluidCacheDisklFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1404 | |||
notification Fluid Cache Disk failure. | ||||
| !alertVirtualDiskPartitionInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1501 | |||
notification Virtual Disk Partition Information | ||||
| !alertVirtualDiskPartitionWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1503 | |||
notification Virtual Disk Partition warning. | ||||
| !alertVirtualDiskPartitionFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1504 | |||
notification Virtual Disk Partition failure. | ||||
| !alertFluidCacheInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1601 | |||
notification Fluid Cache Information | ||||
| !alertfluidCacheWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1603 | |||
notification Fluid Cache warning. | ||||
| !alertFluidCacheFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1604 | |||
notification Fluid Cache failure. | ||||
| !alertFluidCachePoolInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.1701 | |||
notification Fluid Cache Pool Information | ||||
| !alertfluidCachePoolWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.1703 | |||
notification Fluid Cache Pool warning. | ||||
| !alertFluidCachePoolFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.1704 | |||
notification Fluid Cache Pool failure. | ||||
| !alertEEMIStorageManagementInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.10100 | |||
notification Storage Management Information There is no global status change associated with this trap. | ||||
| !alertEEMIStorageManagementNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.10200 | |||
notification There is no global status change associated with this trap. | ||||
| !alertEEMIStorageManagementWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.10300 | |||
notification Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | ||||
| !alertEEMIStorageManagementFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.10400 | |||
notification Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | ||||
| !alertEEMIStorageManagementNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.10500 | |||
notification Storage Management has detected a device independent non-recoverable condition. There is no global status change associated with this trap. | ||||
| !alertEEMIControllerInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.75100 | |||
notification Controller information. | ||||
| !alertEEMIControllerNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.75200 | |||
notification Controller has returned to normal. | ||||
| !alertEEMIControllerWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.75300 | |||
notification Controller warning. | ||||
| !alertEEMIControllerFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.75400 | |||
notification Controller failure. | ||||
| !alertEEMIControllerNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.75500 | |||
notification Controller is non-recoverable. | ||||
| !alertEEMIChannelInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.80100 | |||
notification Channel information. | ||||
| !alertEEMIChannelNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.80200 | |||
notification Channel has returned to normal. | ||||
| !alertEEMIChannelWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.80300 | |||
notification Channel warning. | ||||
| !alertEEMIChannelFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.80400 | |||
notification Channel failure. | ||||
| !alertEEMIChannelNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.80500 | |||
notification Channel is non-recoverable. | ||||
| !alertEEMIEnclosureInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.85100 | |||
notification Enclosure information. | ||||
| !alertEEMIEnclosureNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.85200 | |||
notification Enclosure has returned to normal. | ||||
| !alertEEMIEnclosureWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.85300 | |||
notification Enclosure warning. | ||||
| !alertEEMIEnclosureFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.85400 | |||
notification Enclosure failure. | ||||
| !alertEEMIEnclosureNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.85500 | |||
notification Enclosure is non-recoverable. | ||||
| !alertEEMIArrayDiskInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.90100 | |||
notification Array disk information. | ||||
| !alertEEMIArrayDiskNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.90200 | |||
notification Array disk has returned to normal. | ||||
| !alertEEMIArrayDiskWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.90300 | |||
notification Array disk warning. | ||||
| !alertEEMIArrayDiskFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.90400 | |||
notification Array disk failure. | ||||
| !alertEEMIArrayDiskNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.90500 | |||
notification Array disk is non-recoverable. | ||||
| !alertEMMEMMInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.95100 | |||
notification EMM information. | ||||
| !alertEEMIEMMNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.95200 | |||
notification EMM has returned to normal. | ||||
| !alertEEMIEMMWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.95300 | |||
notification EMM warning. | ||||
| !alertEEMIEMMFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.95400 | |||
notification EMM failure. | ||||
| !alertEEMIEMMNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.95500 | |||
notification EMM is non-recoverable. | ||||
| !alertEEMIPowerSupplyInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.100100 | |||
notification Power supply information. | ||||
| !alertEEMIPowerSupplyNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.100200 | |||
notification Power supply has returned to normal. | ||||
| !alertEEMIPowerSupplyWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.100300 | |||
notification Power supply warning. | ||||
| !alertEEMIPowerSupplyFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.100400 | |||
notification Power supply failure. | ||||
| !alertEEMIPowerSupplyNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.100500 | |||
notification Power supply is non-recoverable. | ||||
| !alertEEMITemperatureProbeInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.105100 | |||
notification Temperature probe information. | ||||
| !alertEEMITemperatureProbeNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.105200 | |||
notification Temperature probe has returned to normal. | ||||
| !alertEEMITemperatureProbeWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.105300 | |||
notification Temperature probe warning. | ||||
| !alertEEMITemperatureProbeFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.105400 | |||
notification Temperature probe failure. | ||||
| !alertEEMITemperatureProbeNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.105500 | |||
notification Temperature probe is non-recoverable. | ||||
| !alertEEMIFanInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.110100 | |||
notification Fan information. | ||||
| !alertEEMIFanNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.110200 | |||
notification Fan has returned to normal. | ||||
| !alertEEMIFanWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.110300 | |||
notification Fan warning. | ||||
| !alertEEMIFanFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.110400 | |||
notification Fan failure. | ||||
| !alertEEMIFanNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.110500 | |||
notification Fan is non-recoverable. | ||||
| !alertEEMIBatteryInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.115100 | |||
notification Battery information. | ||||
| !alertEEMIBatteryNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.115200 | |||
notification Battery has returned to normal. | ||||
| !alertEEMIBatteryWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.115300 | |||
notification Battery warning. | ||||
| !alertEEMIBatteryFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.115400 | |||
notification Battery failure. | ||||
| !alertEEMIBatteryNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.115500 | |||
notification Battery is non-recoverable. | ||||
| !alertEEMIVirtualDiskInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.120100 | |||
notification Virtual disk information. | ||||
| !alertEEMIVirtualDiskNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.120200 | |||
notification Virtual disk has returned to normal. | ||||
| !alertEEMIVirtualDiskWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.120300 | |||
notification Virtual disk warning. | ||||
| !alertEEMIVirtualDiskFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.120400 | |||
notification Virtual disk failure. | ||||
| !alertEEMIVirtualDiskNonRecoverable | 1.3.6.1.4.1.674.10893.1.20.200.0.120500 | |||
notification Virtual disk is non-recoverable. | ||||
| !alertEEMIRedundancyNormal | 1.3.6.1.4.1.674.10893.1.20.200.0.130400 | |||
notification Redundancy has returned to normal. | ||||
| !alertEEMIRedundancyDegraded | 1.3.6.1.4.1.674.10893.1.20.200.0.130500 | |||
notification Redundancy has been degraded. | ||||
| !alertEEMIRedundancyLost | 1.3.6.1.4.1.674.10893.1.20.200.0.130600 | |||
notification Redundancy has been lost. | ||||
| !alertEEMIFluidCacheDiskInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.140100 | |||
notification Fluid Cache Disk Information | ||||
| !alertEEMIfluidCacheDiskWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.140300 | |||
notification Fluid Cache Disk warning. | ||||
| !alertEEMIFluidCacheDisklFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.140400 | |||
notification Fluid Cache Disk failure. | ||||
| !alertEEMIVirtualDiskPartitionInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.150100 | |||
notification Virtual Disk Partition Information | ||||
| !alertEEMIVirtualDiskPartitionWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.150300 | |||
notification Virtual Disk Partition warning. | ||||
| !alertEEMIVirtualDiskPartitionFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.150400 | |||
notification Virtual Disk Partition failure. | ||||
| !alertEEMIFluidCacheInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.160100 | |||
notification Fluid Cache Information | ||||
| !alertEEMIfluidCacheWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.160300 | |||
notification Fluid Cache warning. | ||||
| !alertEEMIFluidCacheFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.160400 | |||
notification Fluid Cache failure. | ||||
| !alertEEMIFluidCachePoolInformation | 1.3.6.1.4.1.674.10893.1.20.200.0.170100 | |||
notification Fluid Cache Pool Information | ||||
| !alertEEMIfluidCachePoolWarning | 1.3.6.1.4.1.674.10893.1.20.200.0.170300 | |||
notification Fluid Cache Pool warning. | ||||
| !alertEEMIFluidCachePoolFailure | 1.3.6.1.4.1.674.10893.1.20.200.0.170400 | |||
notification Fluid Cache Pool failure. | ||||
| !alertRRWEThresholdSASSATASSD | 1.3.6.1.4.1.674.10893.1.20.200.0.170401 | |||
notification Storage Management Information There is no global status change associated with this trap.
| ||||
| !alertRRWEThresholdPCIeSSD | 1.3.6.1.4.1.674.10893.1.20.200.0.170402 | |||
notification Storage Management Information There is no global status change associated with this trap.
| ||||
| SmessageIDEvent | 1.3.6.1.4.1.674.10893.1.20.200.1 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory 0200.0001 Storage Management alert (event) message number. | ||||
| SdescriptionEvent | 1.3.6.1.4.1.674.10893.1.20.200.2 | DisplayString (SIZE (1..64)) | RO | mandatory |
scalar · DisplayString (SIZE (1..64)) · read-only · mandatory 0200.0002 Storage Management event message text describing the alert. | ||||
| SlocationEvent | 1.3.6.1.4.1.674.10893.1.20.200.3 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory 0200.0003 Additional information identifying the location of the object causing the alert. | ||||
| SobjectNameEvent | 1.3.6.1.4.1.674.10893.1.20.200.4 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory 0200.0004 Name of the object as represented in Storage Management causing the alert. | ||||
| SobjectOIDEvent | 1.3.6.1.4.1.674.10893.1.20.200.5 | DisplayString (SIZE (1..64)) | RO | mandatory |
scalar · DisplayString (SIZE (1..64)) · read-only · mandatory 0200.0005 MIB OID of the object causing the alert. | ||||
| SobjectNexusEvent | 1.3.6.1.4.1.674.10893.1.20.200.6 | DisplayString (SIZE (1..64)) | RO | mandatory |
scalar · DisplayString (SIZE (1..64)) · read-only · mandatory 0200.0006 Durable, unique ID of the object causing the alert. | ||||
| ScurrentStatusEvent | 1.3.6.1.4.1.674.10893.1.20.200.7 | DellStatus | RO | mandatory |
scalar · DellStatus · read-only · mandatory 0200.0007 Current status of object causing the alert, if applicable. | ||||
| SpreviousStatusEvent | 1.3.6.1.4.1.674.10893.1.20.200.8 | DellStatus | RO | mandatory |
scalar · DellStatus · read-only · mandatory 0200.0008 Previous status of object causing the alert if applicable. | ||||
| SenhancedMessageIDEvent | 1.3.6.1.4.1.674.10893.1.20.200.9 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory 0200.0001 Enhanced Storage Management Message ID. | ||||
| SsystemFQDNEvent | 1.3.6.1.4.1.674.10893.1.20.200.10 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory 0200.0008 System FQDN of object causing the alert if applicable. | ||||
| SserviceTagEvent | 1.3.6.1.4.1.674.10893.1.20.200.11 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory 0200.0008 Service Tag of object causing the alert if applicable. | ||||
| SchassisServiceTagEvent | 1.3.6.1.4.1.674.10893.1.20.200.12 | DisplayString | RO | mandatory |
scalar · DisplayString · read-only · mandatory 0200.0008 Chassis Service Tag of object causing the alert if applicable. | ||||
Traps / Notifications
- alertArrayDiskFailure
1.3.6.1.4.1.674.10893.1.20.200.0.904 - alertArrayDiskInformation
1.3.6.1.4.1.674.10893.1.20.200.0.901 - alertArrayDiskNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.905 - alertArrayDiskNormal
1.3.6.1.4.1.674.10893.1.20.200.0.902 - alertArrayDiskWarning
1.3.6.1.4.1.674.10893.1.20.200.0.903 - alertBatteryFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1154 - alertBatteryInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1151 - alertBatteryNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.1155 - alertBatteryNormal
1.3.6.1.4.1.674.10893.1.20.200.0.1152 - alertBatteryWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1153 - alertChannelFailure
1.3.6.1.4.1.674.10893.1.20.200.0.804 - alertChannelInformation
1.3.6.1.4.1.674.10893.1.20.200.0.801 - alertChannelNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.805 - alertChannelNormal
1.3.6.1.4.1.674.10893.1.20.200.0.802 - alertChannelWarning
1.3.6.1.4.1.674.10893.1.20.200.0.803 - alertControllerFailure
1.3.6.1.4.1.674.10893.1.20.200.0.754 - alertControllerInformation
1.3.6.1.4.1.674.10893.1.20.200.0.751 - alertControllerNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.755 - alertControllerNormal
1.3.6.1.4.1.674.10893.1.20.200.0.752 - alertControllerWarning
1.3.6.1.4.1.674.10893.1.20.200.0.753 - alertEEMIArrayDiskFailure
1.3.6.1.4.1.674.10893.1.20.200.0.90400 - alertEEMIArrayDiskInformation
1.3.6.1.4.1.674.10893.1.20.200.0.90100 - alertEEMIArrayDiskNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.90500 - alertEEMIArrayDiskNormal
1.3.6.1.4.1.674.10893.1.20.200.0.90200 - alertEEMIArrayDiskWarning
1.3.6.1.4.1.674.10893.1.20.200.0.90300 - alertEEMIBatteryFailure
1.3.6.1.4.1.674.10893.1.20.200.0.115400 - alertEEMIBatteryInformation
1.3.6.1.4.1.674.10893.1.20.200.0.115100 - alertEEMIBatteryNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.115500 - alertEEMIBatteryNormal
1.3.6.1.4.1.674.10893.1.20.200.0.115200 - alertEEMIBatteryWarning
1.3.6.1.4.1.674.10893.1.20.200.0.115300 - alertEEMIChannelFailure
1.3.6.1.4.1.674.10893.1.20.200.0.80400 - alertEEMIChannelInformation
1.3.6.1.4.1.674.10893.1.20.200.0.80100 - alertEEMIChannelNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.80500 - alertEEMIChannelNormal
1.3.6.1.4.1.674.10893.1.20.200.0.80200 - alertEEMIChannelWarning
1.3.6.1.4.1.674.10893.1.20.200.0.80300 - alertEEMIControllerFailure
1.3.6.1.4.1.674.10893.1.20.200.0.75400 - alertEEMIControllerInformation
1.3.6.1.4.1.674.10893.1.20.200.0.75100 - alertEEMIControllerNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.75500 - alertEEMIControllerNormal
1.3.6.1.4.1.674.10893.1.20.200.0.75200 - alertEEMIControllerWarning
1.3.6.1.4.1.674.10893.1.20.200.0.75300 - alertEEMIEMMFailure
1.3.6.1.4.1.674.10893.1.20.200.0.95400 - alertEEMIEMMNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.95500 - alertEEMIEMMNormal
1.3.6.1.4.1.674.10893.1.20.200.0.95200 - alertEEMIEMMWarning
1.3.6.1.4.1.674.10893.1.20.200.0.95300 - alertEEMIEnclosureFailure
1.3.6.1.4.1.674.10893.1.20.200.0.85400 - alertEEMIEnclosureInformation
1.3.6.1.4.1.674.10893.1.20.200.0.85100 - alertEEMIEnclosureNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.85500 - alertEEMIEnclosureNormal
1.3.6.1.4.1.674.10893.1.20.200.0.85200 - alertEEMIEnclosureWarning
1.3.6.1.4.1.674.10893.1.20.200.0.85300 - alertEEMIFanFailure
1.3.6.1.4.1.674.10893.1.20.200.0.110400 - alertEEMIFanInformation
1.3.6.1.4.1.674.10893.1.20.200.0.110100 - alertEEMIFanNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.110500 - alertEEMIFanNormal
1.3.6.1.4.1.674.10893.1.20.200.0.110200 - alertEEMIFanWarning
1.3.6.1.4.1.674.10893.1.20.200.0.110300 - alertEEMIFluidCacheDiskInformation
1.3.6.1.4.1.674.10893.1.20.200.0.140100 - alertEEMIFluidCacheDisklFailure
1.3.6.1.4.1.674.10893.1.20.200.0.140400 - alertEEMIFluidCacheFailure
1.3.6.1.4.1.674.10893.1.20.200.0.160400 - alertEEMIFluidCacheInformation
1.3.6.1.4.1.674.10893.1.20.200.0.160100 - alertEEMIFluidCachePoolFailure
1.3.6.1.4.1.674.10893.1.20.200.0.170400 - alertEEMIFluidCachePoolInformation
1.3.6.1.4.1.674.10893.1.20.200.0.170100 - alertEEMIPowerSupplyFailure
1.3.6.1.4.1.674.10893.1.20.200.0.100400 - alertEEMIPowerSupplyInformation
1.3.6.1.4.1.674.10893.1.20.200.0.100100 - alertEEMIPowerSupplyNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.100500 - alertEEMIPowerSupplyNormal
1.3.6.1.4.1.674.10893.1.20.200.0.100200 - alertEEMIPowerSupplyWarning
1.3.6.1.4.1.674.10893.1.20.200.0.100300 - alertEEMIRedundancyDegraded
1.3.6.1.4.1.674.10893.1.20.200.0.130500 - alertEEMIRedundancyLost
1.3.6.1.4.1.674.10893.1.20.200.0.130600 - alertEEMIRedundancyNormal
1.3.6.1.4.1.674.10893.1.20.200.0.130400 - alertEEMIStorageManagementFailure
1.3.6.1.4.1.674.10893.1.20.200.0.10400 - alertEEMIStorageManagementInformation
1.3.6.1.4.1.674.10893.1.20.200.0.10100 - alertEEMIStorageManagementNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.10500 - alertEEMIStorageManagementNormal
1.3.6.1.4.1.674.10893.1.20.200.0.10200 - alertEEMIStorageManagementWarning
1.3.6.1.4.1.674.10893.1.20.200.0.10300 - alertEEMITemperatureProbeFailure
1.3.6.1.4.1.674.10893.1.20.200.0.105400 - alertEEMITemperatureProbeInformation
1.3.6.1.4.1.674.10893.1.20.200.0.105100 - alertEEMITemperatureProbeNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.105500 - alertEEMITemperatureProbeNormal
1.3.6.1.4.1.674.10893.1.20.200.0.105200 - alertEEMITemperatureProbeWarning
1.3.6.1.4.1.674.10893.1.20.200.0.105300 - alertEEMIVirtualDiskFailure
1.3.6.1.4.1.674.10893.1.20.200.0.120400 - alertEEMIVirtualDiskInformation
1.3.6.1.4.1.674.10893.1.20.200.0.120100 - alertEEMIVirtualDiskNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.120500 - alertEEMIVirtualDiskNormal
1.3.6.1.4.1.674.10893.1.20.200.0.120200 - alertEEMIVirtualDiskPartitionFailure
1.3.6.1.4.1.674.10893.1.20.200.0.150400 - alertEEMIVirtualDiskPartitionInformation
1.3.6.1.4.1.674.10893.1.20.200.0.150100 - alertEEMIVirtualDiskPartitionWarning
1.3.6.1.4.1.674.10893.1.20.200.0.150300 - alertEEMIVirtualDiskWarning
1.3.6.1.4.1.674.10893.1.20.200.0.120300 - alertEEMIfluidCacheDiskWarning
1.3.6.1.4.1.674.10893.1.20.200.0.140300 - alertEEMIfluidCachePoolWarning
1.3.6.1.4.1.674.10893.1.20.200.0.170300 - alertEEMIfluidCacheWarning
1.3.6.1.4.1.674.10893.1.20.200.0.160300 - alertEMMEMMInformation
1.3.6.1.4.1.674.10893.1.20.200.0.95100 - alertEMMFailure
1.3.6.1.4.1.674.10893.1.20.200.0.954 - alertEMMInformation
1.3.6.1.4.1.674.10893.1.20.200.0.951 - alertEMMNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.955 - alertEMMNormal
1.3.6.1.4.1.674.10893.1.20.200.0.952 - alertEMMWarning
1.3.6.1.4.1.674.10893.1.20.200.0.953 - alertEnclosureFailure
1.3.6.1.4.1.674.10893.1.20.200.0.854 - alertEnclosureInformation
1.3.6.1.4.1.674.10893.1.20.200.0.851 - alertEnclosureNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.855 - alertEnclosureNormal
1.3.6.1.4.1.674.10893.1.20.200.0.852 - alertEnclosureWarning
1.3.6.1.4.1.674.10893.1.20.200.0.853 - alertFanFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1104 - alertFanInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1101 - alertFanNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.1105 - alertFanNormal
1.3.6.1.4.1.674.10893.1.20.200.0.1102 - alertFanWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1103 - alertFluidCacheDiskInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1401 - alertFluidCacheDisklFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1404 - alertFluidCacheFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1604 - alertFluidCacheInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1601 - alertFluidCachePoolFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1704 - alertFluidCachePoolInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1701 - alertPowerSupplyFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1004 - alertPowerSupplyInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1001 - alertPowerSupplyNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.1005 - alertPowerSupplyNormal
1.3.6.1.4.1.674.10893.1.20.200.0.1002 - alertPowerSupplyWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1003 - alertRRWEThresholdPCIeSSD
1.3.6.1.4.1.674.10893.1.20.200.0.170402 - alertRRWEThresholdSASSATASSD
1.3.6.1.4.1.674.10893.1.20.200.0.170401 - alertRedundancyDegraded
1.3.6.1.4.1.674.10893.1.20.200.0.1305 - alertRedundancyLost
1.3.6.1.4.1.674.10893.1.20.200.0.1306 - alertRedundancyNormal
1.3.6.1.4.1.674.10893.1.20.200.0.1304 - alertStorageManagementFailure
1.3.6.1.4.1.674.10893.1.20.200.0.104 - alertStorageManagementInformation
1.3.6.1.4.1.674.10893.1.20.200.0.101 - alertStorageManagementNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.105 - alertStorageManagementNormal
1.3.6.1.4.1.674.10893.1.20.200.0.102 - alertStorageManagementWarning
1.3.6.1.4.1.674.10893.1.20.200.0.103 - alertTemperatureProbeFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1054 - alertTemperatureProbeInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1051 - alertTemperatureProbeNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.1055 - alertTemperatureProbeNormal
1.3.6.1.4.1.674.10893.1.20.200.0.1052 - alertTemperatureProbeWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1053 - alertVirtualDiskFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1204 - alertVirtualDiskInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1201 - alertVirtualDiskNonRecoverable
1.3.6.1.4.1.674.10893.1.20.200.0.1205 - alertVirtualDiskNormal
1.3.6.1.4.1.674.10893.1.20.200.0.1202 - alertVirtualDiskPartitionFailure
1.3.6.1.4.1.674.10893.1.20.200.0.1504 - alertVirtualDiskPartitionInformation
1.3.6.1.4.1.674.10893.1.20.200.0.1501 - alertVirtualDiskPartitionWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1503 - alertVirtualDiskWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1203 - alertfluidCacheDiskWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1403 - alertfluidCachePoolWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1703 - alertfluidCacheWarning
1.3.6.1.4.1.674.10893.1.20.200.0.1603