IDRAC-MIB-SMIv2
Dell Inc.This MIB defines MIB objects that make out-of-band iDRAC data available to SNMP management applications. It also defines the traps that iDRAC supports.
snmptranslate -m IDRAC-MIB-SMIv2 -Tpsnmpwalk -v2c -c <community> -m IDRAC-MIB-SMIv2 <host> 1.3.6.1.4.1.674.10892.5Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IoutOfBandGroup | 1.3.6.1.4.1.674.10892.5 | ||||||||||||||||||||
identity This MIB defines MIB objects that make out-of-band iDRAC data available to SNMP management applications. It also defines the traps that iDRAC supports. | |||||||||||||||||||||
| NinformationGroup | 1.3.6.1.4.1.674.10892.5.1 | ||||||||||||||||||||
| NracInfoGroup | 1.3.6.1.4.1.674.10892.5.1.1 | ||||||||||||||||||||
| SracName | 1.3.6.1.4.1.674.10892.5.1.1.1 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the product name of a remote access card. | |||||||||||||||||||||
| SracShortName | 1.3.6.1.4.1.674.10892.5.1.1.2 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the short product name of a remote access card. | |||||||||||||||||||||
| SracDescription | 1.3.6.1.4.1.674.10892.5.1.1.3 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the product description of a remote access card. | |||||||||||||||||||||
| SracManufacturer | 1.3.6.1.4.1.674.10892.5.1.1.4 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the product manufacturer of a remote access card. | |||||||||||||||||||||
| SracVersion | 1.3.6.1.4.1.674.10892.5.1.1.5 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the product version of a remote access card. | |||||||||||||||||||||
| SracURL | 1.3.6.1.4.1.674.10892.5.1.1.6 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the out-of-band UI URL of a remote access card. | |||||||||||||||||||||
| SracType | 1.3.6.1.4.1.674.10892.5.1.1.7 | RacTypeEnum | RO | ||||||||||||||||||
scalar · RacTypeEnum · read-only · current This attribute defines the type of a remote access card. | |||||||||||||||||||||
| SracFirmwareVersion | 1.3.6.1.4.1.674.10892.5.1.1.8 | StringType | RO | 7.10.30.00 | |||||||||||||||||
scalar · StringType · read-only · current This attribute defines the firmware version of a remote access card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NchassisInfoGroup | 1.3.6.1.4.1.674.10892.5.1.2 | ||||||||||||||||||||
| SchassisServiceTag | 1.3.6.1.4.1.674.10892.5.1.2.1 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the service tag of the modular chassis. The value is zero length if not a modular system. | |||||||||||||||||||||
| SchassisNameModular | 1.3.6.1.4.1.674.10892.5.1.2.2 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the chassis name of the modular chassis. The value is zero length if not a modular system. | |||||||||||||||||||||
| SchassisModelModular | 1.3.6.1.4.1.674.10892.5.1.2.3 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the model of the modular chassis. The value is zero length if not a modular system. | |||||||||||||||||||||
| NsystemInfoGroup | 1.3.6.1.4.1.674.10892.5.1.3 | ||||||||||||||||||||
| SsystemFQDN | 1.3.6.1.4.1.674.10892.5.1.3.1 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the fully qualified domain name of the system. For example, hostname.domainname. | |||||||||||||||||||||
| SsystemServiceTag | 1.3.6.1.4.1.674.10892.5.1.3.2 | StringType | RO | 8WM8ST3 | |||||||||||||||||
scalar · StringType · read-only · current This attribute defines the service tag of the system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsystemExpressServiceCode | 1.3.6.1.4.1.674.10892.5.1.3.3 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the express service code of the system. | |||||||||||||||||||||
| SsystemAssetTag | 1.3.6.1.4.1.674.10892.5.1.3.4 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the asset tag of the system. | |||||||||||||||||||||
| SsystemBladeSlotNumber | 1.3.6.1.4.1.674.10892.5.1.3.5 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the slot number of the system in the modular chassis. | |||||||||||||||||||||
| SsystemOSName | 1.3.6.1.4.1.674.10892.5.1.3.6 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the name of the operating system that the host is running. | |||||||||||||||||||||
| SsystemFormFactor | 1.3.6.1.4.1.674.10892.5.1.3.7 | SystemFormFactorEnum | RO | ||||||||||||||||||
scalar · SystemFormFactorEnum · read-only · current This attribute defines the form factor of the system. | |||||||||||||||||||||
| SsystemDataCenterName | 1.3.6.1.4.1.674.10892.5.1.3.8 | StringType | RO | | |||||||||||||||||
scalar · StringType · read-only · current This attribute defines the Data Center locator of the system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsystemAisleName | 1.3.6.1.4.1.674.10892.5.1.3.9 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the Aisle locator of the system. | |||||||||||||||||||||
| SsystemRackName | 1.3.6.1.4.1.674.10892.5.1.3.10 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the Rack locator of the system. | |||||||||||||||||||||
| SsystemRackSlot | 1.3.6.1.4.1.674.10892.5.1.3.11 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the Rack Slot locator of the system. | |||||||||||||||||||||
| SsystemModelName | 1.3.6.1.4.1.674.10892.5.1.3.12 | StringType | RO | PowerEdge C6525 | |||||||||||||||||
scalar · StringType · read-only · current This attribute defines the model name of the system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsystemSystemID | 1.3.6.1.4.1.674.10892.5.1.3.13 | Unsigned16BitRange | RO | ||||||||||||||||||
scalar · Unsigned16BitRange · read-only · current This attribute defines the system ID of the system. | |||||||||||||||||||||
| SsystemOSVersion | 1.3.6.1.4.1.674.10892.5.1.3.14 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the version of the operating system that the host is running. | |||||||||||||||||||||
| SsystemRoomName | 1.3.6.1.4.1.674.10892.5.1.3.15 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the Room locator of the system. | |||||||||||||||||||||
| SsystemChassisSystemHeight | 1.3.6.1.4.1.674.10892.5.1.3.16 | Unsigned8BitRange | RO | ||||||||||||||||||
scalar · Unsigned8BitRange · read-only · current This attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component. (If not applicable, a 'no such name' error is returned.) | |||||||||||||||||||||
| SsystemBladeGeometry | 1.3.6.1.4.1.674.10892.5.1.3.17 | BladeGeometryEnum | RO | ||||||||||||||||||
scalar · BladeGeometryEnum · read-only · current This attribute defines the geometry for a modular system. (If not applicable, a 'no such name' error is returned.) | |||||||||||||||||||||
| SsystemNodeID | 1.3.6.1.4.1.674.10892.5.1.3.18 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the node ID of the system. The node ID provides a unique identifier for the system. | |||||||||||||||||||||
| SsystemOEMOSVersion | 1.3.6.1.4.1.674.10892.5.1.3.19 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current This attribute defines the OEM version of the operating system . | |||||||||||||||||||||
| SsystemLockdownMode | 1.3.6.1.4.1.674.10892.5.1.3.20 | SystemLockdownModeEnum | RO | ||||||||||||||||||
scalar · SystemLockdownModeEnum · read-only · current This attribute defines the system Lockdown mode is enabled or disabled. | |||||||||||||||||||||
| NstatusGroup | 1.3.6.1.4.1.674.10892.5.2 | ||||||||||||||||||||
| SglobalSystemStatus | 1.3.6.1.4.1.674.10892.5.2.1 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
scalar · ObjectStatusEnum · read-only · current This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SsystemLCDStatus | 1.3.6.1.4.1.674.10892.5.2.2 | ObjectStatusEnum | RO | ||||||||||||||||||
scalar · ObjectStatusEnum · read-only · current This attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included. | |||||||||||||||||||||
| SglobalStorageStatus | 1.3.6.1.4.1.674.10892.5.2.3 | ObjectStatusEnum | RO | ||||||||||||||||||
scalar · ObjectStatusEnum · read-only · current This attribute defines the overall storage status being monitored by the remote access card. | |||||||||||||||||||||
| SsystemPowerState | 1.3.6.1.4.1.674.10892.5.2.4 | PowerStateStatusEnum | RO | ||||||||||||||||||
scalar · PowerStateStatusEnum · read-only · current This attribute defines the power state of the system. | |||||||||||||||||||||
| SsystemPowerUpTime | 1.3.6.1.4.1.674.10892.5.2.5 | Unsigned32BitRange | RO | ||||||||||||||||||
scalar · Unsigned32BitRange · read-only · current This attribute defines the power-up time of the system in seconds. | |||||||||||||||||||||
| NalertGroup | 1.3.6.1.4.1.674.10892.5.3 | ||||||||||||||||||||
| NalertVariablesGroup | 1.3.6.1.4.1.674.10892.5.3.1 | ||||||||||||||||||||
| SalertMessageID | 1.3.6.1.4.1.674.10892.5.3.1.1 | OCTET STRING (SIZE (0..8)) | RO | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..8)) · read-only · current Message ID of the event. | |||||||||||||||||||||
| SalertMessage | 1.3.6.1.4.1.674.10892.5.3.1.2 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current Message describing the alert. | |||||||||||||||||||||
| SalertCurrentStatus | 1.3.6.1.4.1.674.10892.5.3.1.3 | ObjectStatusEnum | RO | ||||||||||||||||||
scalar · ObjectStatusEnum · read-only · current Current status of object causing the alert, if applicable. | |||||||||||||||||||||
| SalertSystemServiceTag | 1.3.6.1.4.1.674.10892.5.3.1.4 | OCTET STRING (SIZE (0..16)) | RO | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..16)) · read-only · current Service tag of the system. | |||||||||||||||||||||
| SalertSystemFQDN | 1.3.6.1.4.1.674.10892.5.3.1.5 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current Fully qualified domain name of the system. | |||||||||||||||||||||
| SalertFQDD | 1.3.6.1.4.1.674.10892.5.3.1.6 | OCTET STRING (SIZE (0..512)) | RO | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..512)) · read-only · current Fully qualified device descriptor of the device. | |||||||||||||||||||||
| SalertDeviceDisplayName | 1.3.6.1.4.1.674.10892.5.3.1.7 | OCTET STRING (SIZE (0..512)) | RO | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..512)) · read-only · current Display name of the device/FQDD. | |||||||||||||||||||||
| SalertMessageArguments | 1.3.6.1.4.1.674.10892.5.3.1.8 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current Concatenated set of strings representing the message arguments of the event. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. | |||||||||||||||||||||
| SalertChassisServiceTag | 1.3.6.1.4.1.674.10892.5.3.1.9 | OCTET STRING (SIZE (0..16)) | RO | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..16)) · read-only · current For modular systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length). | |||||||||||||||||||||
| SalertChassisName | 1.3.6.1.4.1.674.10892.5.3.1.10 | OCTET STRING (SIZE (0..255)) | RO | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..255)) · read-only · current For modular systems, the chassis name of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length). | |||||||||||||||||||||
| SalertRacFQDN | 1.3.6.1.4.1.674.10892.5.3.1.11 | StringType | RO | ||||||||||||||||||
scalar · StringType · read-only · current Fully qualified domain name of the remote access card. | |||||||||||||||||||||
| NalertTrapGroup | 1.3.6.1.4.1.674.10892.5.3.2 | ||||||||||||||||||||
| NsystemAlertTrapGroup | 1.3.6.1.4.1.674.10892.5.3.2.1 | ||||||||||||||||||||
| !alertNetworkFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2089 | ||||||||||||||||||||
notification · current Network failure or critical event. | |||||||||||||||||||||
| !alertNetworkWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2090 | ||||||||||||||||||||
notification · current Network warning. | |||||||||||||||||||||
| !alertNetworkInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2091 | ||||||||||||||||||||
notification · current Network information. | |||||||||||||||||||||
| !alertFanFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2153 | ||||||||||||||||||||
notification · current Fan failure. | |||||||||||||||||||||
| !alertFanWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2154 | ||||||||||||||||||||
notification · current Fan warning. | |||||||||||||||||||||
| !alertFanInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2155 | ||||||||||||||||||||
notification · current Fan information. | |||||||||||||||||||||
| !alertTemperatureProbeFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2161 | ||||||||||||||||||||
notification · current Temperature sensor has detected a failure value. | |||||||||||||||||||||
| !alertTemperatureProbeWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2162 | ||||||||||||||||||||
notification · current Temperature sensor has detected a warning value. | |||||||||||||||||||||
| !alertTemperatureProbeNormal | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2163 | ||||||||||||||||||||
notification · current Temperature sensor value is within range. | |||||||||||||||||||||
| !alertVoltageProbeFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2169 | ||||||||||||||||||||
notification · current Voltage sensor has detected a failure value. | |||||||||||||||||||||
| !alertVoltageProbeWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2170 | ||||||||||||||||||||
notification · current Voltage sensor has detected a warning value. | |||||||||||||||||||||
| !alertVoltageProbeNormal | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2171 | ||||||||||||||||||||
notification · current Voltage sensor reading is within range. | |||||||||||||||||||||
| !alertAmperageProbeFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2177 | ||||||||||||||||||||
notification · current Current sensor has detected a failure value. | |||||||||||||||||||||
| !alertAmperageProbeWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2178 | ||||||||||||||||||||
notification · current Current sensor has detected a warning value. | |||||||||||||||||||||
| !alertAmperageProbeNormal | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2179 | ||||||||||||||||||||
notification · current Current sensor reading is within range. | |||||||||||||||||||||
| !alertPowerSupplyFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2185 | ||||||||||||||||||||
notification · current Power supply has detected a failure. | |||||||||||||||||||||
| !alertPowerSupplyWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2186 | ||||||||||||||||||||
notification · current Power supply has detected a warning. | |||||||||||||||||||||
| !alertPowerSupplyNormal | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2187 | ||||||||||||||||||||
notification · current Power supply has returned to normal. | |||||||||||||||||||||
| !alertIntegratedDualSDModuleFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2209 | ||||||||||||||||||||
notification · current Integrated Dual SD Module failure. | |||||||||||||||||||||
| !alertIntegratedDualSDModuleWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2210 | ||||||||||||||||||||
notification · current Integrated Dual SD Module warning. | |||||||||||||||||||||
| !alertIntegratedDualSDModuleInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2211 | ||||||||||||||||||||
notification · current Integrated Dual SD Module information. | |||||||||||||||||||||
| !alertBatteryFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2225 | ||||||||||||||||||||
notification · current Battery has failed or battery is absent. | |||||||||||||||||||||
| !alertBatteryWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2226 | ||||||||||||||||||||
notification · current Battery is low. | |||||||||||||||||||||
| !alertBatteryNormal | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2227 | ||||||||||||||||||||
notification · current Battery state has returned to normal; or battery presence had been detected. | |||||||||||||||||||||
| !alertAutomaticSystemRecovery | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2233 | ||||||||||||||||||||
notification · current Automatic system recovery (ASR) was performed. | |||||||||||||||||||||
| !alertProcessorDeviceStatusFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2241 | ||||||||||||||||||||
notification · current Processor device status has detected a failure. | |||||||||||||||||||||
| !alertProcessorDeviceStatusWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2242 | ||||||||||||||||||||
notification · current Processor device status has detected a warning. | |||||||||||||||||||||
| !alertProcessorDeviceStatusNormal | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2243 | ||||||||||||||||||||
notification · current Processor device status has returned to normal. | |||||||||||||||||||||
| !alertLinkStatusFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2249 | ||||||||||||||||||||
notification · current Link status failure or critical event. | |||||||||||||||||||||
| !alertLinkStatusWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2250 | ||||||||||||||||||||
notification · current Link status warning. | |||||||||||||||||||||
| !alertLinkStatusInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2251 | ||||||||||||||||||||
notification · current Link status information. | |||||||||||||||||||||
| !alertMemoryDeviceFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2265 | ||||||||||||||||||||
notification · current Memory device status is critical. | |||||||||||||||||||||
| !alertMemoryDeviceWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2266 | ||||||||||||||||||||
notification · current Memory device status is noncritical. | |||||||||||||||||||||
| !alertMemoryDeviceInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2267 | ||||||||||||||||||||
notification · current Memory device informational event. | |||||||||||||||||||||
| !alertPowerUsageFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2273 | ||||||||||||||||||||
notification · current The system halted because system power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold. | |||||||||||||||||||||
| !alertPowerUsageWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2274 | ||||||||||||||||||||
notification · current System performance degraded. | |||||||||||||||||||||
| !alertPowerUsageInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2275 | ||||||||||||||||||||
notification · current System performance restored. | |||||||||||||||||||||
| !alertPhysicalDiskFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2297 | ||||||||||||||||||||
notification · current Physical disk failure. | |||||||||||||||||||||
| !alertPhysicalDiskWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2298 | ||||||||||||||||||||
notification · current Physical disk warning. | |||||||||||||||||||||
| !alertPhysicalDiskInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2299 | ||||||||||||||||||||
notification · current Physical disk information. | |||||||||||||||||||||
| !alertHardwareConfigurationFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2329 | ||||||||||||||||||||
notification · current Hardware configuration failure or critical event. | |||||||||||||||||||||
| !alertHardwareConfigurationWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2330 | ||||||||||||||||||||
notification · current Hardware configuration warning. | |||||||||||||||||||||
| !alertHardwareConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2331 | ||||||||||||||||||||
notification · current Hardware configuration information. | |||||||||||||||||||||
| !alertSoftwareConfigurationFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2337 | ||||||||||||||||||||
notification · current Software configuration failure. | |||||||||||||||||||||
| !alertSoftwareConfigurationWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2338 | ||||||||||||||||||||
notification · current Software configuration warning. | |||||||||||||||||||||
| !alertSoftwareConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2339 | ||||||||||||||||||||
notification · current Software configuration information. | |||||||||||||||||||||
| !alertSystemEventLogFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2377 | ||||||||||||||||||||
notification · current System Event Log failure or critical event. | |||||||||||||||||||||
| !alertSystemEventLogWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2378 | ||||||||||||||||||||
notification · current System Event Log warning. | |||||||||||||||||||||
| !alertSystemEventLogInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2379 | ||||||||||||||||||||
notification · current System Event Log information. | |||||||||||||||||||||
| !alertSecurityFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2385 | ||||||||||||||||||||
notification · current Security failure or critical event. | |||||||||||||||||||||
| !alertSecurityWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2386 | ||||||||||||||||||||
notification · current Security warning. | |||||||||||||||||||||
| !alertSecurityInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2387 | ||||||||||||||||||||
notification · current Security information. | |||||||||||||||||||||
| !alertCableFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2393 | ||||||||||||||||||||
notification · current Cable failure or critical event. | |||||||||||||||||||||
| !alertOSFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2409 | ||||||||||||||||||||
notification · current A critical stop occurred during OS load; or a runtime critical stop occurred. | |||||||||||||||||||||
| !alertOSInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2411 | ||||||||||||||||||||
notification · current An OS graceful stop occurred; or an OS graceful shut-down occurred. | |||||||||||||||||||||
| !alertPCIDeviceFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2417 | ||||||||||||||||||||
notification · current An error was detected for a PCI device. | |||||||||||||||||||||
| !alertPCIDeviceWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2418 | ||||||||||||||||||||
notification · current A warning event was detected for a PCI device. | |||||||||||||||||||||
| !alertPCIDeviceInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2419 | ||||||||||||||||||||
notification · current An informational event was detected for a PCI device. | |||||||||||||||||||||
| !alertBiosPostFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2425 | ||||||||||||||||||||
notification · current System BIOS detected a failure. | |||||||||||||||||||||
| !alertInternaliDRACMemoryUnresponsive | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2433 | ||||||||||||||||||||
notification · current Unable to communicate with internal iDRAC memory | |||||||||||||||||||||
| !alertServerIdleTime | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2435 | ||||||||||||||||||||
notification · current Server is either idle or underutilized | |||||||||||||||||||||
| !alertProcessorDeviceAbsent | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2457 | ||||||||||||||||||||
notification · current Processor device is absent. | |||||||||||||||||||||
| !alertPowerSupplyAbsent | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2465 | ||||||||||||||||||||
notification · current Power supply is absent. | |||||||||||||||||||||
| !alertRedundancyLost | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2473 | ||||||||||||||||||||
notification · current Redundancy is lost. | |||||||||||||||||||||
| !alertRedundancyDegraded | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2474 | ||||||||||||||||||||
notification · current Redundancy is degraded. | |||||||||||||||||||||
| !alertRedundancyInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2475 | ||||||||||||||||||||
notification · current Redundancy information. | |||||||||||||||||||||
| !alertIntegratedDualSDModuleAbsent | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2481 | ||||||||||||||||||||
notification · current Integrated Dual SD Module is absent. | |||||||||||||||||||||
| !alertIntegratedDualSDModuleRedundancyLost | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2489 | ||||||||||||||||||||
notification · current Integrated Dual SD Module redundancy is lost. | |||||||||||||||||||||
| !alertIntegratedDualSDModuleRedundancyDegraded | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2490 | ||||||||||||||||||||
notification · current Integrated Dual SD Module redundancy is degraded. | |||||||||||||||||||||
| !alertIntegratedDualSDModuleRedundancyInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2491 | ||||||||||||||||||||
notification · current Integrated Dual SD Module redundancy information. | |||||||||||||||||||||
| !alertvFlashMediaDeviceFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2505 | ||||||||||||||||||||
notification · current vFlash Media device failure. | |||||||||||||||||||||
| !alertvFlashMediaDeviceWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2506 | ||||||||||||||||||||
notification · current vFlash Media device warning. | |||||||||||||||||||||
| !alertvFlashMediaDeviceInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2507 | ||||||||||||||||||||
notification · current vFlash Media device information. | |||||||||||||||||||||
| !alertvFlashMediaDeviceAbsent | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2515 | ||||||||||||||||||||
notification · current vFlash Media device is absent. | |||||||||||||||||||||
| !alertTemperatureStatisticsFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2521 | ||||||||||||||||||||
notification · current Temperature has been above the warning or critical threshold level for a long enough period of time to be considered in a critical state. | |||||||||||||||||||||
| !alertTemperatureStatisticsWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2522 | ||||||||||||||||||||
notification · current Temperature has been above the warning or critical threshold level for a long enough period of time to be considered in a warning state. | |||||||||||||||||||||
| !alertRACInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2531 | ||||||||||||||||||||
notification · current RAC information. | |||||||||||||||||||||
| !alertFiberChannelFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2537 | ||||||||||||||||||||
notification · current Fiber Channel failure or critical event. | |||||||||||||||||||||
| !alertFiberChannelWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2538 | ||||||||||||||||||||
notification · current Fiber Channel warning. | |||||||||||||||||||||
| !alertFiberChannelInformation | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2539 | ||||||||||||||||||||
notification · current Fiber Channel information. | |||||||||||||||||||||
| !alertCMCFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2545 | ||||||||||||||||||||
notification · current Chassis Management Controller detected an error. | |||||||||||||||||||||
| !alertCMCWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2546 | ||||||||||||||||||||
notification · current Chassis Management Controller detected a warning. | |||||||||||||||||||||
| !alertIOVirtualizationFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2553 | ||||||||||||||||||||
notification · current IO Virtualization failure or critical event. | |||||||||||||||||||||
| !alertSystemPerformanceWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.2650 | ||||||||||||||||||||
notification · current System Performance warning. | |||||||||||||||||||||
| !alertLiquidCoolingLeakFailure | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3049 | ||||||||||||||||||||
notification · current A large leak is detected on the device | |||||||||||||||||||||
| !alertLiquidCoolingLeakWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3050 | ||||||||||||||||||||
notification · current A small leak is detected on the device | |||||||||||||||||||||
| !alertLiquidCoolingLeakInformational | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3051 | ||||||||||||||||||||
notification · current A small leak that was earlier detected on the device is now resolved. | |||||||||||||||||||||
| !alertSDKSystemWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3082 | ||||||||||||||||||||
notification · current The iDRAC generated a trap event due to a warning from SDK plugin. | |||||||||||||||||||||
| !alertSDKSystemInformational | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3083 | ||||||||||||||||||||
notification · current The iDRAC generated a trap as iDRAC SDK plugin started working as expected. | |||||||||||||||||||||
| !alertSDPMSystemCritical | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3289 | ||||||||||||||||||||
notification · current A System Defined Persistent Memory(SDPM) error is detected on the device | |||||||||||||||||||||
| !alertSDPMSystemWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3290 | ||||||||||||||||||||
notification · current The iDRAC generated a trap event due to a warning from Software Defined Persistent Memory(SDPM). | |||||||||||||||||||||
| !alertSDPMSystemInformational | 1.3.6.1.4.1.674.10892.5.3.2.1.0.3291 | ||||||||||||||||||||
notification · current The iDRAC generated a trap as iDRAC Software Defined Persistent Memory(SDPM) started working as expected. | |||||||||||||||||||||
| !alertCertificateValidityError | 1.3.6.1.4.1.674.10892.5.3.2.1.0.9441 | ||||||||||||||||||||
notification · current Certificate Validity Failure or Critical event | |||||||||||||||||||||
| !alertCertificateValidityWarning | 1.3.6.1.4.1.674.10892.5.3.2.1.0.9442 | ||||||||||||||||||||
notification · current Certificate Validity State Change Warning | |||||||||||||||||||||
| NstorageAlertTrapGroup | 1.3.6.1.4.1.674.10892.5.3.2.2 | ||||||||||||||||||||
| !alertStorageManagementFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4177 | ||||||||||||||||||||
notification · current Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | |||||||||||||||||||||
| !alertStorageManagementWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4178 | ||||||||||||||||||||
notification · current Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | |||||||||||||||||||||
| !alertStorageManagementInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4179 | ||||||||||||||||||||
notification · current Storage Management Information. There is no global status change associated with this trap. | |||||||||||||||||||||
| !alertStorageFanFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4201 | ||||||||||||||||||||
notification · current Fan failure. | |||||||||||||||||||||
| !alertStorageFanWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4202 | ||||||||||||||||||||
notification · current Fan warning. | |||||||||||||||||||||
| !alertStorageFanInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4203 | ||||||||||||||||||||
notification · current Fan information. | |||||||||||||||||||||
| !alertStorageTemperatureProbeFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4209 | ||||||||||||||||||||
notification · current Temperature probe failure. | |||||||||||||||||||||
| !alertStorageTemperatureProbeWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4210 | ||||||||||||||||||||
notification · current Temperature probe warning. | |||||||||||||||||||||
| !alertStorageTemperatureProbeInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4211 | ||||||||||||||||||||
notification · current Temperature probe information. | |||||||||||||||||||||
| !alertStoragePowerSupplyFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4233 | ||||||||||||||||||||
notification · current Power supply failure. | |||||||||||||||||||||
| !alertStoragePowerSupplyWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4234 | ||||||||||||||||||||
notification · current Power supply warning. | |||||||||||||||||||||
| !alertStoragePowerSupplyInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4235 | ||||||||||||||||||||
notification · current Power supply information. | |||||||||||||||||||||
| !alertStorageBatteryFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4273 | ||||||||||||||||||||
notification · current Battery failure. | |||||||||||||||||||||
| !alertStorageBatteryWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4274 | ||||||||||||||||||||
notification · current Battery warning. | |||||||||||||||||||||
| !alertStorageBatteryInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4275 | ||||||||||||||||||||
notification · current Battery information. | |||||||||||||||||||||
| !alertStorageControllerFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4329 | ||||||||||||||||||||
notification · current Controller failure. | |||||||||||||||||||||
| !alertStorageControllerWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4330 | ||||||||||||||||||||
notification · current Controller warning. | |||||||||||||||||||||
| !alertStorageControllerInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4331 | ||||||||||||||||||||
notification · current Controller information. | |||||||||||||||||||||
| !alertStorageEnclosureFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4337 | ||||||||||||||||||||
notification · current Enclosure failure. | |||||||||||||||||||||
| !alertStorageEnclosureWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4338 | ||||||||||||||||||||
notification · current Enclosure warning. | |||||||||||||||||||||
| !alertStorageEnclosureInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4339 | ||||||||||||||||||||
notification · current Enclosure information. | |||||||||||||||||||||
| !alertStoragePhysicalDiskFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4345 | ||||||||||||||||||||
notification · current Physical disk failure. | |||||||||||||||||||||
| !alertStoragePhysicalDiskWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4346 | ||||||||||||||||||||
notification · current Physical disk warning. | |||||||||||||||||||||
| !alertStoragePhysicalDiskInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4347 | ||||||||||||||||||||
notification · current Physical disk information. | |||||||||||||||||||||
| !alertStorageVirtualDiskFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4353 | ||||||||||||||||||||
notification · current Virtual disk failure. | |||||||||||||||||||||
| !alertStorageVirtualDiskWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4354 | ||||||||||||||||||||
notification · current Virtual disk warning. | |||||||||||||||||||||
| !alertStorageVirtualDiskInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4355 | ||||||||||||||||||||
notification · current Virtual disk information. | |||||||||||||||||||||
| !alertStorageSolidstateDrive | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4370 | ||||||||||||||||||||
notification · current SSD is less than the threshold value. | |||||||||||||||||||||
| !alertStorageSecurityFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4433 | ||||||||||||||||||||
notification · current Storage Security failure or critical event. | |||||||||||||||||||||
| !alertStorageSecurityWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4434 | ||||||||||||||||||||
notification · current Storage Security warning. | |||||||||||||||||||||
| !alertStorageSecurityInformation | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4435 | ||||||||||||||||||||
notification · current Storage Security information. | |||||||||||||||||||||
| !alertStorageSoftwareDefinedSubSystemFailure | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4761 | ||||||||||||||||||||
notification · current Software defined storage subsystem failure. | |||||||||||||||||||||
| !alertStorageSoftwareDefinedSubSystemWarning | 1.3.6.1.4.1.674.10892.5.3.2.2.0.4762 | ||||||||||||||||||||
notification · current Software defined storage subsystem warning. | |||||||||||||||||||||
| NupdatesAlertTrapGroup | 1.3.6.1.4.1.674.10892.5.3.2.3 | ||||||||||||||||||||
| !alertUpdateJobInformation | 1.3.6.1.4.1.674.10892.5.3.2.3.0.6211 | ||||||||||||||||||||
notification · current Update job information. | |||||||||||||||||||||
| !alertSoftwareChangeUpdateWarning | 1.3.6.1.4.1.674.10892.5.3.2.3.0.6314 | ||||||||||||||||||||
notification · current Software change update warning. | |||||||||||||||||||||
| NauditAlertTrapGroup | 1.3.6.1.4.1.674.10892.5.3.2.4 | ||||||||||||||||||||
| !alertTemperatureProbeChangeFailure | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8305 | ||||||||||||||||||||
notification · current Temperature increase Error. | |||||||||||||||||||||
| !alertTemperatureProbeReadWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8306 | ||||||||||||||||||||
notification · current Unable to read Temperature Sensors | |||||||||||||||||||||
| !alertPowerSupplyAuditFailure | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8329 | ||||||||||||||||||||
notification · current Power Supply audit failure or critical event. | |||||||||||||||||||||
| !alertPowerSupplyAuditWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8330 | ||||||||||||||||||||
notification · current Power Supply audit warning. | |||||||||||||||||||||
| !alertPowerUsageAuditFailure | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8417 | ||||||||||||||||||||
notification · current Power usage audit failure or critical event. | |||||||||||||||||||||
| !alertPowerUsageAuditWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8418 | ||||||||||||||||||||
notification · current Power usage audit warning. | |||||||||||||||||||||
| !alertPowerUsageAuditInformation | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8419 | ||||||||||||||||||||
notification · current Power usage audit information. | |||||||||||||||||||||
| !alertHWCAuditWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8474 | ||||||||||||||||||||
notification · current Hardware Configuration warning. | |||||||||||||||||||||
| !alertHWCAuditInformation | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8475 | ||||||||||||||||||||
notification · current Hardware Configuration Information. | |||||||||||||||||||||
| !alertUserTrackingWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8490 | ||||||||||||||||||||
notification · current User Tracking warning. | |||||||||||||||||||||
| !alertiDRACIPAddressChange | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8499 | ||||||||||||||||||||
notification · current iDRAC IP address has changed. | |||||||||||||||||||||
| !alertLicenseFailure | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8513 | ||||||||||||||||||||
notification · current License failure. | |||||||||||||||||||||
| !alertLicenseWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8514 | ||||||||||||||||||||
notification · current License warning. | |||||||||||||||||||||
| !alertLicenseInformation | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8515 | ||||||||||||||||||||
notification · current License information. | |||||||||||||||||||||
| !alertPCIDeviceAuditWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8562 | ||||||||||||||||||||
notification · current PCI device audit warning. | |||||||||||||||||||||
| !alertSystemPowerStateChangeInformation | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8579 | ||||||||||||||||||||
notification · current Host is going through a power state change (powering on or powering off). | |||||||||||||||||||||
| !alertDebugWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8594 | ||||||||||||||||||||
notification · current Debug authorization failed. | |||||||||||||||||||||
| !alertDebugInformation | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8595 | ||||||||||||||||||||
notification · current Debug authorized. | |||||||||||||||||||||
| !alertRacConfigurationChangeWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8674 | ||||||||||||||||||||
notification · current Configuration or state Change warning. | |||||||||||||||||||||
| !alertRacConfigurationChangeInformation | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8675 | ||||||||||||||||||||
notification · current Configuration or state Change Information. | |||||||||||||||||||||
| !alertCMCAuditFailure | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8689 | ||||||||||||||||||||
notification · current Chassis Management Controller audit failure or critical event. | |||||||||||||||||||||
| !alertCMCAuditWarning | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8690 | ||||||||||||||||||||
notification · current Chassis Management Controller audit warning. | |||||||||||||||||||||
| !alertCMCAuditInformation | 1.3.6.1.4.1.674.10892.5.3.2.4.0.8691 | ||||||||||||||||||||
notification · current Chassis Management Controller audit information. | |||||||||||||||||||||
| NconfigurationAlertTrapGroup | 1.3.6.1.4.1.674.10892.5.3.2.5 | ||||||||||||||||||||
| !alertJobControlConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10267 | ||||||||||||||||||||
notification · current Job Control configuration information. | |||||||||||||||||||||
| !alertPRDeviceDetectionWarning | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10298 | ||||||||||||||||||||
notification · current The indicated device is not detected. | |||||||||||||||||||||
| !alertTestTrapEvent | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10395 | ||||||||||||||||||||
notification · current The iDRAC generated a test trap event in response to a user request. | |||||||||||||||||||||
| !alertSWCConfigurationFailure | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10529 | ||||||||||||||||||||
notification · current Software configuration failure. | |||||||||||||||||||||
| !alertSWCConfigurationWarning | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10530 | ||||||||||||||||||||
notification · current Software configuration warning. | |||||||||||||||||||||
| !alertSWCConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10531 | ||||||||||||||||||||
notification · current Software configuration Information. | |||||||||||||||||||||
| !alertIPAddressConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10547 | ||||||||||||||||||||
notification · current IP Address configuration information. | |||||||||||||||||||||
| !alertSecurityConfigurationWarning | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10578 | ||||||||||||||||||||
notification · current Security configuration warning. | |||||||||||||||||||||
| !alertPCIDeviceConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10611 | ||||||||||||||||||||
notification · current PCI device configuration information. | |||||||||||||||||||||
| !alertSystemConfigurationChangeInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10627 | ||||||||||||||||||||
notification · current A/Many System Configuration Item/Items are changed. | |||||||||||||||||||||
| !alertAutoDiscoveryInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10635 | ||||||||||||||||||||
notification · current Auto discovery information. | |||||||||||||||||||||
| !alertNetworkConfigurationWarning | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10770 | ||||||||||||||||||||
notification · current Network configuration warning. | |||||||||||||||||||||
| !alertNetworkConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.10771 | ||||||||||||||||||||
notification · current Network configuration information. | |||||||||||||||||||||
| !alertSDKConfigurationWarning | 1.3.6.1.4.1.674.10892.5.3.2.5.0.11274 | ||||||||||||||||||||
notification · current The iDRAC generated a trap event with SDK plugin configuration change warning. | |||||||||||||||||||||
| !alertSDKConfigurationInformation | 1.3.6.1.4.1.674.10892.5.3.2.5.0.11275 | ||||||||||||||||||||
notification · current The iDRAC generated a trap event with SDK plugin Configuration change information. | |||||||||||||||||||||
| NsystemDetailsGroup | 1.3.6.1.4.1.674.10892.5.4 | ||||||||||||||||||||
| NmIBVersionGroup | 1.3.6.1.4.1.674.10892.5.4.1 | ||||||||||||||||||||
| SmIBMajorVersionNumber | 1.3.6.1.4.1.674.10892.5.4.1.1 | Unsigned8BitRange | RO | ||||||||||||||||||
scalar · Unsigned8BitRange · read-only · current 0001.0001 This attribute defines the major version number for the version of this MIB supported by the iDRAC. | |||||||||||||||||||||
| SmIBMinorVersionNumber | 1.3.6.1.4.1.674.10892.5.4.1.2 | Unsigned8BitRange | RO | ||||||||||||||||||
scalar · Unsigned8BitRange · read-only · current 0001.0002 This attribute defines the minor version number for the version of this MIB supported by the iDRAC. | |||||||||||||||||||||
| SmIBMaintenanceVersionNumber | 1.3.6.1.4.1.674.10892.5.4.1.3 | Unsigned8BitRange | RO | ||||||||||||||||||
scalar · Unsigned8BitRange · read-only · current 0001.0003 This attribute defines the maintenance version number for the version of this MIB supported by the iDRAC. | |||||||||||||||||||||
| NsystemStateGroup | 1.3.6.1.4.1.674.10892.5.4.200 | ||||||||||||||||||||
| TsystemStateTable | 1.3.6.1.4.1.674.10892.5.4.200.10 | NA | |||||||||||||||||||
table · not-accessible · current 0200.0010 This object defines the System State Table. | |||||||||||||||||||||
| RsystemStateTableEntry | 1.3.6.1.4.1.674.10892.5.4.200.10.1 | NA | |||||||||||||||||||
row · not-accessible · current 0200.0010.0001 This object defines the System State Table Entry. | |||||||||||||||||||||
| CsystemStatechassisIndex | 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0200.0010.0001.0001 This attribute defines the index (one based) of this system chassis. | |||||||||||||||||||||
| CsystemStateGlobalSystemStatus | 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software. | |||||||||||||||||||||
| CsystemStateChassisState | 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0200.0010.0001.0003 This attribute defines the state settings of this system chassis. | |||||||||||||||||||||
| CsystemStateChassisStatus | 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0004 This attribute defines the status of this system chassis. | |||||||||||||||||||||
| CsystemStatePowerUnitStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0005 This attribute lists the state settings of each power unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a power unit. The first byte returned represents the state settings of the first power unit, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStatePowerUnitStatusRedundancy | 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 | StatusRedundancyEnum | RO | ||||||||||||||||||
column · StatusRedundancyEnum · read-only · current 0200.0010.0001.0006 This attribute defines the combined redundancy status of all power units of this system. | |||||||||||||||||||||
| CsystemStatePowerUnitStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0007 This attribute lists the redundancy status of each power unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the redundancy status of a power unit. The first byte returned represents the redundancy status of the first power unit, etc. The bytes have the same definition type as StatusRedundancyEnum. | |||||||||||||||||||||
| CsystemStatePowerSupplyStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0008 This attribute lists the state settings of each power supply of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a power supply. The first byte returned represents the state settings of the first power supply, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStatePowerSupplyStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0009 This attribute defines the combined status of all power supplies of this system. | |||||||||||||||||||||
| CsystemStatePowerSupplyStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0010 This attribute lists the status of each power supply of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a power supply. The first byte returned represents the status of the first power supply, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateVoltageStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0011 This attribute lists the state settings of each voltage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a voltage probe. The first byte returned represents the state settings of the first voltage probe, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateVoltageStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0012 This attribute defines the combined status of all voltage probes of this system. | |||||||||||||||||||||
| CsystemStateVoltageStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0013 This attribute lists the status of each voltage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a voltage probe. The first byte returned represents the status of the first voltage probe, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateAmperageStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0014 This attribute lists the state settings of each amperage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of an amperage probe. The first byte returned represents the state settings of the first amperage probe, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateAmperageStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0015 This attribute defines the combined status of all amperage probes of this system. | |||||||||||||||||||||
| CsystemStateAmperageStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0016 This attribute lists the status of each amperage probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of an amperage probe. The first byte returned represents the status of the first amperage probe, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateCoolingUnitStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0017 This attribute lists the state settings of each cooling unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a cooling unit. The first byte returned represents the state settings of the first cooling unit, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateCoolingUnitStatusRedundancy | 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 | StatusRedundancyEnum | RO | ||||||||||||||||||
column · StatusRedundancyEnum · read-only · current 0200.0010.0001.0018 This attribute defines the combined redundancy status of all cooling units of this system. | |||||||||||||||||||||
| CsystemStateCoolingUnitStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the redundancy status of a cooling unit. The first byte returned represents the redundancy status of the first cooling unit, etc. The bytes have the same definition type as StatusRedundancyEnum. | |||||||||||||||||||||
| CsystemStateCoolingDeviceStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0020 This attribute lists the state settings of each cooling device of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a cooling device. The first byte returned represents the state settings of the first cooling device, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateCoolingDeviceStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0021 This attribute defines the combined status of all cooling devices of this system. | |||||||||||||||||||||
| CsystemStateCoolingDeviceStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0022 This attribute lists the status of each cooling device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling device. The first byte returned represents the status of the first cooling device, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateTemperatureStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0023 This attribute lists the state settings of each temperature probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a temperature probe. The first byte returned represents the state settings of the first temperature probe, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateTemperatureStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0024 This attribute defines the combined status of all temperature probes of this system. | |||||||||||||||||||||
| CsystemStateTemperatureStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0025 This attribute lists the status of each temperature probe of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a temperature probe. The first byte returned represents the status of the first temperature probe, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateMemoryDeviceStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0026 This attribute lists the state settings of each memory device of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a memory device. The first byte returned represents the state settings of the first memory device, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateMemoryDeviceStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0027 This attribute defines the combined status of all memory devices of this system. | |||||||||||||||||||||
| CsystemStateMemoryDeviceStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0028 This attribute lists the status of each memory device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a memory device. The first byte returned represents the status of the first memory device, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateChassisIntrusionStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0029 This attribute lists the state settings of each intrusion detection device of this system chassis. The results are returned as a binary octet string where each byte of the octet string represents the state settings of an intrusion detection device. The first byte returned represents the state settings of the first intrusion detection device, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateChassisIntrusionStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0030 This attribute defines the combined status of all intrusion detection devices of this system chassis. | |||||||||||||||||||||
| CsystemStateChassisIntrusionStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0031 This attribute lists the status of each intrusion detection device of this system chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an intrusion detection device. The first byte returned represents the status of the first intrusion detection device, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStatePowerUnitStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0042 This attribute defines the combined status of all power units of this chassis. | |||||||||||||||||||||
| CsystemStatePowerUnitStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0043 This attribute lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit. The first byte returned represents the status of the first power unit, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateCoolingUnitStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0044 This attribute defines the combined status of all cooling units of this system. | |||||||||||||||||||||
| CsystemStateCoolingUnitStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0045 This attribute lists the status of each cooling unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit. The first byte returned represents the status of the first cooling unit, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateProcessorDeviceStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system. | |||||||||||||||||||||
| CsystemStateProcessorDeviceStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0051 This attribute lists the status of each processor device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a processor device. The first byte returned represents the status of the first processor device, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateBatteryStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0052 This attribute defines the combined status of all batteries of this system. | |||||||||||||||||||||
| CsystemStateBatteryStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0053 This attribute lists the status of each battery of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateSDCardUnitStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system. | |||||||||||||||||||||
| CsystemStateSDCardUnitStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0055 This attribute lists the status of each SD Card unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card unit. The first byte returned represents the status of the first SD Card unit, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateSDCardDeviceStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0056 This attribute defines the combined status of all SD Card devices of this system. | |||||||||||||||||||||
| CsystemStateSDCardDeviceStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0057 This attribute lists the status of each SD Card device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device. The first byte returned represents the status of the first SD Card device, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateIDSDMCardUnitStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM Card units of this system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemStateIDSDMCardUnitStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of an IDSDM Card unit. The first byte returned represents the status of the first IDSDM Card unit, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateIDSDMCardDeviceStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemStateIDSDMCardDeviceStatusList | 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of an IDSDM Card device. The first byte returned represents the status of the first IDSDM Card device, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateTemperatureStatisticsStateDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0062 This attribute lists the state settings of each temperature statistics object of this system. The results are returned as a binary octet string where each byte of the octet string represents the state settings of a temperature statistics object. The first byte returned represents the state settings of the first temperature statistics object, etc. The bytes have the same definition type as StateSettingsFlags. | |||||||||||||||||||||
| CsystemStateTemperatureStatisticsStatusCombined | 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0063 This attribute defines the combined status of all temperature statistics objects of this system. | |||||||||||||||||||||
| CsystemStateTemperatureStatisticsStatusDetails | 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 | OCTET STRING (SIZE (1..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (1..128)) · read-only · current 0200.0010.0001.0064 This attribute lists the status of each temperature statistics object of this system. The results are returned as a binary octet string where each byte of the octet string represents the status of a temperature statistics object. The first byte returned represents the status of the first temperature statistics object, etc. The bytes have the same definition type as ObjectStatusEnum. | |||||||||||||||||||||
| CsystemStateCMCStatus | 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0200.0010.0001.0065 This attribute defines the status of CMC. | |||||||||||||||||||||
| NchassisInformationGroup | 1.3.6.1.4.1.674.10892.5.4.300 | ||||||||||||||||||||
| SnumEventLogEntries | 1.3.6.1.4.1.674.10892.5.4.300.1 | Unsigned32BitRange | RO | ||||||||||||||||||
scalar · Unsigned32BitRange · read-only · current 0300.0001.0000 This attribute provides the number of entries currently in the eventLogTable. | |||||||||||||||||||||
| SnumLCLogEntries | 1.3.6.1.4.1.674.10892.5.4.300.2 | Unsigned32BitRange | RO | ||||||||||||||||||
scalar · Unsigned32BitRange · read-only · current 0300.0002.0000 This attribute provides the number of entries currently in the lcLogTable. Note: This attribute can only be accessed via SNMPv3 queries. | |||||||||||||||||||||
| TchassisInformationTable | 1.3.6.1.4.1.674.10892.5.4.300.10 | NA | |||||||||||||||||||
table · not-accessible · current 0300.0010 This object defines the Chassis Information Table. | |||||||||||||||||||||
| RchassisInformationTableEntry | 1.3.6.1.4.1.674.10892.5.4.300.10.1 | NA | |||||||||||||||||||
row · not-accessible · current 0300.0010.0001 This object defines the Chassis Information Table Entry. | |||||||||||||||||||||
| CchassisIndexChassisInformation | 1.3.6.1.4.1.674.10892.5.4.300.10.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0010.0001.0001 This attribute defines the index (one based) of the system chassis. | |||||||||||||||||||||
| CchassisStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.300.10.1.2 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0300.0010.0001.0002 This attribute defines the state capabilities of the system chassis. | |||||||||||||||||||||
| CchassisStateSettings | 1.3.6.1.4.1.674.10892.5.4.300.10.1.3 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0300.0010.0001.0003 This attribute defines the state settings of the system chassis. | |||||||||||||||||||||
| CchassisStatus | 1.3.6.1.4.1.674.10892.5.4.300.10.1.4 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0300.0010.0001.0004 This attribute defines the status of the system chassis. | |||||||||||||||||||||
| CchassisparentIndexReference | 1.3.6.1.4.1.674.10892.5.4.300.10.1.5 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0010.0001.0005 This attribute defines the index (one based) to the parent system of this system chassis, if any. | |||||||||||||||||||||
| CchassisType | 1.3.6.1.4.1.674.10892.5.4.300.10.1.6 | ChassisTypeEnum | RO | ||||||||||||||||||
column · ChassisTypeEnum · read-only · current 0300.0010.0001.0006 This attribute defines the system type of the system chassis. | |||||||||||||||||||||
| CchassisName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.7 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0010.0001.0007 This attribute defines the user-assigned name of the system chassis. | |||||||||||||||||||||
| CchassisManufacturerName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.8 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0010.0001.0008 This attribute defines the name of the manufacturer of the system chassis. | |||||||||||||||||||||
| CchassisModelTypeName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.9 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0010.0001.0009 This attribute defines the system model type of the system chassis. | |||||||||||||||||||||
| CchassisAssetTagName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.10 | OCTET STRING (SIZE (0..10)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..10)) · read-only · current 0300.0010.0001.0010 This attribute defines the asset tag name of the system chassis. | |||||||||||||||||||||
| CchassisServiceTagName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.11 | OCTET STRING (SIZE (0..7)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..7)) · read-only · current 0300.0010.0001.0011 This attribute defines the service tag name of the system chassis. | |||||||||||||||||||||
| CchassisID | 1.3.6.1.4.1.674.10892.5.4.300.10.1.12 | Unsigned8BitRange | RO | ||||||||||||||||||
column · Unsigned8BitRange · read-only · current 0300.0010.0001.0012 This attribute defines the system ID. If the value is 254 (0xFE), the attribute systemIDExtension provides the system ID. | |||||||||||||||||||||
| CchassisIDExtension | 1.3.6.1.4.1.674.10892.5.4.300.10.1.13 | Unsigned16BitRange | RO | ||||||||||||||||||
column · Unsigned16BitRange · read-only · current 0300.0010.0001.0013 This attribute defines the system ID extension. | |||||||||||||||||||||
| CchassisSystemClass | 1.3.6.1.4.1.674.10892.5.4.300.10.1.14 | ChassisSystemClassEnum | RO | ||||||||||||||||||
column · ChassisSystemClassEnum · read-only · current 0300.0010.0001.0014 This attribute defines the system class. | |||||||||||||||||||||
| CchassisSystemName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.15 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0010.0001.0015 This attribute defines the host name of the system chassis. | |||||||||||||||||||||
| CchassisLEDControlCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.24 | LEDControlCapabilitiesFlags | RO | ||||||||||||||||||
column · LEDControlCapabilitiesFlags · read-only · current 0300.0010.0001.0024 This attribute defines the capabilities of the LED control hardware in the system chassis. | |||||||||||||||||||||
| CchassisLEDControlSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.25 | LEDControlSettingsFlags | RO | ||||||||||||||||||
column · LEDControlSettingsFlags · read-only · current 0300.0010.0001.0025 This attribute defines the reading and setting of the LED control hardware in the system chassis. | |||||||||||||||||||||
| CchassisIdentifyFlashControlCapabilities | 1.3.6.1.4.1.674.10892.5.4.300.10.1.28 | ChassisIdentifyControlCapabilitiesFlags | RO | ||||||||||||||||||
column · ChassisIdentifyControlCapabilitiesFlags · read-only · current 0300.0010.0001.0028 This attribute defines if the system allows setting of the system front panel LED to flash. | |||||||||||||||||||||
| CchassisIdentifyFlashControlSettings | 1.3.6.1.4.1.674.10892.5.4.300.10.1.29 | ChassisIdentifyControlSettingsFlags | RO | ||||||||||||||||||
column · ChassisIdentifyControlSettingsFlags · read-only · current 0300.0010.0001.0029 This attribute setting causes the system front panel LED to flash. | |||||||||||||||||||||
| CchassisLockPresent | 1.3.6.1.4.1.674.10892.5.4.300.10.1.30 | BooleanType | RO | ||||||||||||||||||
column · BooleanType · read-only · current 0300.0010.0001.0030 If true, a system lock is present on the system chassis. | |||||||||||||||||||||
| CchassishostControlCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.31 | HostControlCapabilitiesFlags | RO | ||||||||||||||||||
column · HostControlCapabilitiesFlags · read-only · current 0300.0010.0001.0031 This attribute defines the capabilities of the host control function. | |||||||||||||||||||||
| CchassishostControlSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.32 | HostControlSettingsFlags | RO | ||||||||||||||||||
column · HostControlSettingsFlags · read-only · current 0300.0010.0001.0032 This attribute defines the settings of the host control function. | |||||||||||||||||||||
| CchassiswatchDogControlCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.33 | WatchDogControlCapabilitiesFlags | RO | ||||||||||||||||||
column · WatchDogControlCapabilitiesFlags · read-only · current 0300.0010.0001.0033 This attribute defines the capabilities of the watchdog control function. | |||||||||||||||||||||
| CchassiswatchDogControlSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.34 | WatchControlSettingsFlags | RO | ||||||||||||||||||
column · WatchControlSettingsFlags · read-only · current 0300.0010.0001.0034 This attribute defines the settings of the watchdog control function. | |||||||||||||||||||||
| CchassiswatchDogControlExpiryTimeCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.35 | WatchDogTimerCapabilitiesFlags | RO | ||||||||||||||||||
column · WatchDogTimerCapabilitiesFlags · read-only · current 0300.0010.0001.0035 This attribute defines the capabilities of the watchdog control expiry timer function. | |||||||||||||||||||||
| CchassiswatchDogControlExpiryTime | 1.3.6.1.4.1.674.10892.5.4.300.10.1.36 | Unsigned16BitRange | RO | ||||||||||||||||||
column · Unsigned16BitRange · read-only · current 0300.0010.0001.0036 This attribute defines the current watchdog timer value in seconds. | |||||||||||||||||||||
| CchassisPowerButtonControlCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.38 | PowerButtonControlCapabilitiesFlags | RO | ||||||||||||||||||
column · PowerButtonControlCapabilitiesFlags · read-only · current 0300.0010.0001.0038 This attribute defines the capabilities of the power button control hardware in the system chassis. | |||||||||||||||||||||
| CchassisPowerButtonControlSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.39 | PowerButtonControlSettingsFlags | RO | ||||||||||||||||||
column · PowerButtonControlSettingsFlags · read-only · current 0300.0010.0001.0039 This attribute defines the reading and setting of the power button control hardware in the system chassis. | |||||||||||||||||||||
| CchassisNMIButtonControlCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.44 | NMIButtonControlCapabilitiesFlags | RO | ||||||||||||||||||
column · NMIButtonControlCapabilitiesFlags · read-only · current 0300.0010.0001.0044 This attribute defines the capabilities of the NMI button control hardware in the system chassis. | |||||||||||||||||||||
| CchassisNMIButtonControlSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.300.10.1.45 | NMIButtonControlSettingsFlags | RO | ||||||||||||||||||
column · NMIButtonControlSettingsFlags · read-only · current 0300.0010.0001.0045 This attribute defines the reading and setting of the NMI button control hardware in the system chassis. | |||||||||||||||||||||
| CchassisSystemProperties | 1.3.6.1.4.1.674.10892.5.4.300.10.1.46 | SystemPropertiesFlags | RO | ||||||||||||||||||
column · SystemPropertiesFlags · read-only · current 0300.0010.0001.0046 This attribute defines the properties of the system chassis. | |||||||||||||||||||||
| CchassisSystemRevisionNumber | 1.3.6.1.4.1.674.10892.5.4.300.10.1.47 | Unsigned8BitRange | RO | ||||||||||||||||||
column · Unsigned8BitRange · read-only · current 0300.0010.0001.0047 This attribute defines the revision number of the system where zero indicates the original version of the system chassis. The revision number is not available on all systems. | |||||||||||||||||||||
| CchassisSystemRevisionName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.48 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0010.0001.0048 This attribute defines the revision name of the system, if applicable. | |||||||||||||||||||||
| CchassisExpressServiceCodeName | 1.3.6.1.4.1.674.10892.5.4.300.10.1.49 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0010.0001.0049 This attribute defines the Express Service Code of the system chassis. | |||||||||||||||||||||
| TeventLogTable | 1.3.6.1.4.1.674.10892.5.4.300.40 | NA | |||||||||||||||||||
table · not-accessible · current 0300.0040 This object defines the Event (ESM) Log Table. | |||||||||||||||||||||
| ReventLogTableEntry | 1.3.6.1.4.1.674.10892.5.4.300.40.1 | NA | |||||||||||||||||||
row · not-accessible · current 0300.0040.0001 This object defines the Event (ESM) Log Table Entry. | |||||||||||||||||||||
| CeventLogchassisIndex | 1.3.6.1.4.1.674.10892.5.4.300.40.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0040.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CeventLogRecordIndex | 1.3.6.1.4.1.674.10892.5.4.300.40.1.2 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0300.0040.0001.0002 This attribute defines the index (one based) of the event log record. | |||||||||||||||||||||
| CeventLogStateCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.300.40.1.3 | StateCapabilitiesLogUniqueFlags | RO | ||||||||||||||||||
column · StateCapabilitiesLogUniqueFlags · read-only · current 0300.0040.0001.0003 This attribute defines the state capabilities of the object that is writing the event log. | |||||||||||||||||||||
| CeventLogStateSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.300.40.1.4 | StateSettingsLogUniqueFlags | RO | ||||||||||||||||||
column · StateSettingsLogUniqueFlags · read-only · current 0300.0040.0001.0004 This attribute defines the state settings of the object that is writing the event log. | |||||||||||||||||||||
| CeventLogRecord | 1.3.6.1.4.1.674.10892.5.4.300.40.1.5 | OCTET STRING (SIZE (0..1024)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..1024)) · read-only · current 0300.0040.0001.0005 This attribute defines the data of the event log record. | |||||||||||||||||||||
| CeventLogFormat | 1.3.6.1.4.1.674.10892.5.4.300.40.1.6 | LogFormatType | RO | ||||||||||||||||||
column · LogFormatType · read-only · current 0300.0040.0001.0006 This attribute defines the format of the event log record. | |||||||||||||||||||||
| CeventLogSeverityStatus | 1.3.6.1.4.1.674.10892.5.4.300.40.1.7 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0300.0040.0001.0007 This attribute defines the severity of the event log record. | |||||||||||||||||||||
| CeventLogDateName | 1.3.6.1.4.1.674.10892.5.4.300.40.1.8 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0300.0040.0001.0008 This attribute defines the date and time of the event log record. | |||||||||||||||||||||
| TsystemBIOSTable | 1.3.6.1.4.1.674.10892.5.4.300.50 | NA | |||||||||||||||||||
table · not-accessible · current 0300.0050 This object defines the System BIOS Table. | |||||||||||||||||||||
| RsystemBIOSTableEntry | 1.3.6.1.4.1.674.10892.5.4.300.50.1 | NA | |||||||||||||||||||
row · not-accessible · current 0300.0050.0001 This object defines the System BIOS Table Entry. | |||||||||||||||||||||
| CsystemBIOSchassisIndex | 1.3.6.1.4.1.674.10892.5.4.300.50.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CsystemBIOSIndex | 1.3.6.1.4.1.674.10892.5.4.300.50.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0050.0001.0002 This attribute defines the index (one based) of the system BIOS. | |||||||||||||||||||||
| CsystemBIOSStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.300.50.1.3 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0300.0050.0001.0003 This attribute defines the state capabilities of the system BIOS. | |||||||||||||||||||||
| CsystemBIOSStateSettings | 1.3.6.1.4.1.674.10892.5.4.300.50.1.4 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0300.0050.0001.0004 This attribute defines the state settings of the system BIOS. | |||||||||||||||||||||
| CsystemBIOSStatus | 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0300.0050.0001.0005 This attribute defines the status of the system BIOS. | |||||||||||||||||||||
| CsystemBIOSReleaseDateName | 1.3.6.1.4.1.674.10892.5.4.300.50.1.7 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0300.0050.0001.0007 This attribute defines the release date name of the system BIOS. | |||||||||||||||||||||
| CsystemBIOSVersionName | 1.3.6.1.4.1.674.10892.5.4.300.50.1.8 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0050.0001.0008 This attribute defines the version name of the system BIOS. | |||||||||||||||||||||
| CsystemBIOSManufacturerName | 1.3.6.1.4.1.674.10892.5.4.300.50.1.11 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0050.0001.0011 This attribute defines the name of the manufacturer of the system BIOS. | |||||||||||||||||||||
| TfirmwareTable | 1.3.6.1.4.1.674.10892.5.4.300.60 | NA | |||||||||||||||||||
table · not-accessible · current 0300.0060 This object defines the Firmware Table. | |||||||||||||||||||||
| RfirmwareTableEntry | 1.3.6.1.4.1.674.10892.5.4.300.60.1 | NA | |||||||||||||||||||
row · not-accessible · current 0300.0060.0001 This object defines the Firmware Table Entry. | |||||||||||||||||||||
| CfirmwarechassisIndex | 1.3.6.1.4.1.674.10892.5.4.300.60.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CfirmwareIndex | 1.3.6.1.4.1.674.10892.5.4.300.60.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0060.0001.0002 This attribute defines the index (one based) of the firmware. | |||||||||||||||||||||
| CfirmwareStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.300.60.1.3 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0300.0060.0001.0003 This attribute defines the state capabilities of the firmware. | |||||||||||||||||||||
| CfirmwareStateSettings | 1.3.6.1.4.1.674.10892.5.4.300.60.1.4 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0300.0060.0001.0004 This attribute defines the state settings of the firmware. | |||||||||||||||||||||
| CfirmwareStatus | 1.3.6.1.4.1.674.10892.5.4.300.60.1.5 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0300.0060.0001.0005 This attribute defines the status of the firmware. | |||||||||||||||||||||
| CfirmwareSize | 1.3.6.1.4.1.674.10892.5.4.300.60.1.6 | Unsigned16BitRange | RO | ||||||||||||||||||
column · Unsigned16BitRange · read-only · current 0300.0060.0001.0006 This attribute defines the image size of the firmware in KBytes. Zero indicates size is unknown. | |||||||||||||||||||||
| CfirmwareType | 1.3.6.1.4.1.674.10892.5.4.300.60.1.7 | FirmwareType | RO | ||||||||||||||||||
column · FirmwareType · read-only · current 0300.0060.0001.0007 This attribute defines the type of firmware. | |||||||||||||||||||||
| CfirmwareTypeName | 1.3.6.1.4.1.674.10892.5.4.300.60.1.8 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0060.0001.0008 This attribute defines the type name of the firmware. | |||||||||||||||||||||
| CfirmwareUpdateCapabilities | 1.3.6.1.4.1.674.10892.5.4.300.60.1.9 | Unsigned16BitRange | RO | ||||||||||||||||||
column · Unsigned16BitRange · read-only · current 0300.0060.0001.0009 This attribute defines the bitmap of supported methods for firmware update. | |||||||||||||||||||||
| CfirmwareVersionName | 1.3.6.1.4.1.674.10892.5.4.300.60.1.11 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0060.0001.0011 This attribute defines the version of the firmware. | |||||||||||||||||||||
| TintrusionTable | 1.3.6.1.4.1.674.10892.5.4.300.70 | NA | |||||||||||||||||||
table · not-accessible · current 0300.0070 This object defines the Intrusion Table. | |||||||||||||||||||||
| RintrusionTableEntry | 1.3.6.1.4.1.674.10892.5.4.300.70.1 | NA | |||||||||||||||||||
row · not-accessible · current 0300.0070.0001 This object defines the Intrusion Table Entry. | |||||||||||||||||||||
| CintrusionchassisIndex | 1.3.6.1.4.1.674.10892.5.4.300.70.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0070.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CintrusionIndex | 1.3.6.1.4.1.674.10892.5.4.300.70.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0070.0001.0002 This attribute defines the index (one based) of the intrusion sensor. | |||||||||||||||||||||
| CintrusionStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.300.70.1.3 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0300.0070.0001.0003 This attribute defines the state capabilities of the intrusion sensor. | |||||||||||||||||||||
| CintrusionStateSettings | 1.3.6.1.4.1.674.10892.5.4.300.70.1.4 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0300.0070.0001.0004 This attribute defines the state settings of the intrusion sensor. | |||||||||||||||||||||
| CintrusionStatus | 1.3.6.1.4.1.674.10892.5.4.300.70.1.5 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 0300.0070.0001.0005 This attribute defines the status of the intrusion sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CintrusionReading | 1.3.6.1.4.1.674.10892.5.4.300.70.1.6 | IntrusionReadingEnum | RO | 1 | |||||||||||||||||
column · IntrusionReadingEnum · read-only · current 0300.0070.0001.0006 This attribute defines the reading of the intrusion sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CintrusionType | 1.3.6.1.4.1.674.10892.5.4.300.70.1.7 | IntrusionTypeEnum | RO | ||||||||||||||||||
column · IntrusionTypeEnum · read-only · current 0300.0070.0001.0007 This attribute defines the type of the intrusion sensor. | |||||||||||||||||||||
| CintrusionLocationName | 1.3.6.1.4.1.674.10892.5.4.300.70.1.8 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0300.0070.0001.0008 This attribute defines the location of the intrusion sensor. | |||||||||||||||||||||
| TlcLogTable | 1.3.6.1.4.1.674.10892.5.4.300.90 | NA | |||||||||||||||||||
table · not-accessible · current 0300.0090 This object defines the Lifecycle (LC) Log Table. Lifecycle (LC) Log table records are ordered from oldest to newest. Note: This table can only be accessed via SNMPv3 queries. | |||||||||||||||||||||
| RlcLogTableEntry | 1.3.6.1.4.1.674.10892.5.4.300.90.1 | NA | |||||||||||||||||||
row · not-accessible · current 0300.0090.0001 This object defines the Lifcycle (LC) Log Table Entry. | |||||||||||||||||||||
| ClcLogChassisIndex | 1.3.6.1.4.1.674.10892.5.4.300.90.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0300.0090.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| ClcLogRecordIndex | 1.3.6.1.4.1.674.10892.5.4.300.90.1.2 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0300.0090.0001.0002 This attribute defines the index (one based) of the LC log record. | |||||||||||||||||||||
| ClcLogSequenceNumber | 1.3.6.1.4.1.674.10892.5.4.300.90.1.3 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0300.0090.0001.0003 This attribute defines the LC Log sequence number of the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogCategory | 1.3.6.1.4.1.674.10892.5.4.300.90.1.4 | LcLogCategoryEnum | RO | ||||||||||||||||||
column · LcLogCategoryEnum · read-only · current 0300.0090.0001.0004 This attribute defines the category of the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogSeverityStatus | 1.3.6.1.4.1.674.10892.5.4.300.90.1.5 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0300.0090.0001.0005 This attribute defines the severity of the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogDateName | 1.3.6.1.4.1.674.10892.5.4.300.90.1.6 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0300.0090.0001.0006 This attribute defines the date and time of the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogFQDD | 1.3.6.1.4.1.674.10892.5.4.300.90.1.7 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current 0300.0090.0001.0007 Fully qualified device descriptor (FQDD) of the device associated with the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogMessageID | 1.3.6.1.4.1.674.10892.5.4.300.90.1.8 | OCTET STRING (SIZE (0..8)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..8)) · read-only · current 0300.0090.0001.0008 This attribute defines the Message ID of the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogMessage | 1.3.6.1.4.1.674.10892.5.4.300.90.1.9 | OCTET STRING (SIZE (0..512)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..512)) · read-only · current 0300.0090.0001.0009 This attribute defines the message of the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogDetailedDescription | 1.3.6.1.4.1.674.10892.5.4.300.90.1.10 | OCTET STRING (SIZE (0..2048)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..2048)) · read-only · current 0300.0090.0001.0010 This attribute defines the detailed description of the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogRecommededAction | 1.3.6.1.4.1.674.10892.5.4.300.90.1.11 | OCTET STRING (SIZE (0..2048)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..2048)) · read-only · current 0300.0090.0001.0011 This attribute defines an optional recommended action associated with the event associated with the LC log record. | |||||||||||||||||||||
| ClcLogComment | 1.3.6.1.4.1.674.10892.5.4.300.90.1.12 | OCTET STRING (SIZE (0..128)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..128)) · read-only · current 0300.0090.0001.0012 This attribute defines an optional user comment associated with the event associated with the LC log record. | |||||||||||||||||||||
| NpowerGroup | 1.3.6.1.4.1.674.10892.5.4.600 | ||||||||||||||||||||
| TpowerUnitTable | 1.3.6.1.4.1.674.10892.5.4.600.10 | NA | |||||||||||||||||||
table · not-accessible · current 0600.0010 This object defines the Power Unit Table. | |||||||||||||||||||||
| RpowerUnitTableEntry | 1.3.6.1.4.1.674.10892.5.4.600.10.1 | NA | |||||||||||||||||||
row · not-accessible · current 0600.0010.0001 This object defines the Power Unit Table Entry. | |||||||||||||||||||||
| CpowerUnitchassisIndex | 1.3.6.1.4.1.674.10892.5.4.600.10.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0600.0010.0001.0001 This attribute defines the index (one based) of the system chassis. | |||||||||||||||||||||
| CpowerUnitIndex | 1.3.6.1.4.1.674.10892.5.4.600.10.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0600.0010.0001.0002 This attribute defines the index (one based) of the power unit. | |||||||||||||||||||||
| CpowerUnitStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.10.1.3 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0600.0010.0001.0003 This attribute defines the state capabilities of the power unit. | |||||||||||||||||||||
| CpowerUnitStateSettings | 1.3.6.1.4.1.674.10892.5.4.600.10.1.4 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0600.0010.0001.0004 This attribute defines the state settings of the power unit. | |||||||||||||||||||||
| CpowerUnitRedundancyStatus | 1.3.6.1.4.1.674.10892.5.4.600.10.1.5 | StatusRedundancyEnum | RO | ||||||||||||||||||
column · StatusRedundancyEnum · read-only · current 0600.0010.0001.0005 This attribute defines the redundancy status of the power unit. | |||||||||||||||||||||
| CpowerSupplyCountForRedundancy | 1.3.6.1.4.1.674.10892.5.4.600.10.1.6 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0600.0010.0001.0006 This attribute defines the total number of power supplies required for this power unit to have full redundancy. | |||||||||||||||||||||
| CpowerUnitName | 1.3.6.1.4.1.674.10892.5.4.600.10.1.7 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0600.0010.0001.0007 This attribute defines the name of the power unit. | |||||||||||||||||||||
| CpowerUnitStatus | 1.3.6.1.4.1.674.10892.5.4.600.10.1.8 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0600.0010.0001.0008 This attribute defines the status of the power unit. | |||||||||||||||||||||
| TpowerSupplyTable | 1.3.6.1.4.1.674.10892.5.4.600.12 | NA | |||||||||||||||||||
table · not-accessible · current 0600.0012 This object defines the Power Supply Table. | |||||||||||||||||||||
| RpowerSupplyTableEntry | 1.3.6.1.4.1.674.10892.5.4.600.12.1 | NA | |||||||||||||||||||
row · not-accessible · current 0600.0012.0001 This object defines the Power Supply Table Entry. | |||||||||||||||||||||
| CpowerSupplychassisIndex | 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0012.0001.0001 This attribute defines the index (one based) of the system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyIndex | 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0012.0001.0002 This attribute defines the index (one based) of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyStateCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 | PowerSupplyStateCapabilitiesUniqueFlags | RO | 0 | |||||||||||||||||
column · PowerSupplyStateCapabilitiesUniqueFlags · read-only · current 0600.0012.0001.0003 This attribute defines the state capabilities of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyStateSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 | PowerSupplyStateSettingsUniqueFlags | RO | 242 | |||||||||||||||||
column · PowerSupplyStateSettingsUniqueFlags · read-only · current 0600.0012.0001.0004 This attribute defines the state settings of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyStatus | 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 0600.0012.0001.0005 This attribute defines the status of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyOutputWatts | 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 | Signed32BitRange | RO | 24000 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0012.0001.0006 This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyType | 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 | PowerSupplyTypeEnum | RO | 9 | |||||||||||||||||
column · PowerSupplyTypeEnum · read-only · current 0600.0012.0001.0007 This attribute defines the type of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyLocationName | 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 | String64 | RO | PS1 Status | |||||||||||||||||
column · String64 · read-only · current 0600.0012.0001.0008 This attribute defines the location of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyMaximumInputVoltage | 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 | Signed32BitRange | RO | 264 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0012.0001.0009 This attribute defines the maximum input voltage of the power supply (in Volts). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplypowerUnitIndexReference | 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0012.0001.0010 This attribute defines the index to the associated power unit if the power supply is part of a power unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplySensorState | 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 | PowerSupplySensorStateFlags | RO | 1 | |||||||||||||||||
column · PowerSupplySensorStateFlags · read-only · current 0600.0012.0001.0011 This attribute defines the state reported by the power supply sensor. This attribute supplements the attribute powerSupplyStateSettingsUnique. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyConfigurationErrorType | 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 | PowerSupplyConfigurationErrorTypeEnum | RO | ||||||||||||||||||
column · PowerSupplyConfigurationErrorTypeEnum · read-only · current 0600.0012.0001.0012 This attribute defines the type of configuration error reported by the power supply sensor. When the configurationError bit is on in the value for the attribute powerSupplySensorState, a value is returned for this attribute; otherwise, a value is not returned for this attribute. | |||||||||||||||||||||
| CpowerSupplyPowerMonitorCapable | 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current 0600.0012.0001.0013 This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyRatedInputWattage | 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 | Signed32BitRange | RO | 27000 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0012.0001.0014 This attribute defines the rated input wattage of the power supply (in tenths of Watts). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyFQDD | 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 | FQDDString | RO | PSU.ChassisSlot.1-1-1 | |||||||||||||||||
column · FQDDString · read-only · current 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyCurrentInputVoltage | 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 | Signed32BitRange | RO | 228 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0012.0001.0016 This attribute defines the current input voltage to the power supply (in Volts). Example values from LibreNMS test devices
| |||||||||||||||||||||
| TvoltageProbeTable | 1.3.6.1.4.1.674.10892.5.4.600.20 | NA | |||||||||||||||||||
table · not-accessible · current 0600.0020 This object defines the Voltage Probe Table. | |||||||||||||||||||||
| RvoltageProbeTableEntry | 1.3.6.1.4.1.674.10892.5.4.600.20.1 | NA | |||||||||||||||||||
row · not-accessible · current 0600.0020.001 This object defines the Voltage Probe Table Entry. | |||||||||||||||||||||
| CvoltageProbechassisIndex | 1.3.6.1.4.1.674.10892.5.4.600.20.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0020.0001.0001 This attribute defines the index (one based) of the system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeIndex | 1.3.6.1.4.1.674.10892.5.4.600.20.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0020.0001.0002 This attribute defines the index (one based) of the voltage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.20.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0600.0020.0001.0003 This attribute defines the state capabilities of the voltage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeStateSettings | 1.3.6.1.4.1.674.10892.5.4.600.20.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 0600.0020.0001.0004 This attribute defines the state settings of the voltage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeStatus | 1.3.6.1.4.1.674.10892.5.4.600.20.1.5 | StatusProbeEnum | RO | 3 | |||||||||||||||||
column · StatusProbeEnum · read-only · current 0600.0020.0001.0005 This attribute defines the probe status of the voltage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeReading | 1.3.6.1.4.1.674.10892.5.4.600.20.1.6 | Signed32BitRange | RO | 228000 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0020.0001.0006 This attribute defines the reading for a voltage probe of type other than voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, the value returned for this attribute is the voltage that the probe is reading in millivolts. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeType | 1.3.6.1.4.1.674.10892.5.4.600.20.1.7 | VoltageTypeEnum | RO | 16 | |||||||||||||||||
column · VoltageTypeEnum · read-only · current 0600.0020.0001.0007 This attribute defines the type of the voltage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeLocationName | 1.3.6.1.4.1.674.10892.5.4.600.20.1.8 | String64 | RO | System Board BP P5V PG | |||||||||||||||||
column · String64 · read-only · current 0600.0020.0001.0008 This attribute defines the location name of the voltage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeUpperNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.600.20.1.9 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. | |||||||||||||||||||||
| CvoltageProbeUpperCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.20.1.10 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0020.0001.0010 This attribute defines the upper critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. | |||||||||||||||||||||
| CvoltageProbeUpperNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.20.1.11 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0020.0001.0011 This attribute defines the upper noncritical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. | |||||||||||||||||||||
| CvoltageProbeLowerNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.20.1.12 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0020.0001.0012 This attribute defines the lower noncritical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. | |||||||||||||||||||||
| CvoltageProbeLowerCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.20.1.13 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0020.0001.0013 This attribute defines the lower critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. | |||||||||||||||||||||
| CvoltageProbeLowerNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.600.20.1.14 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. | |||||||||||||||||||||
| CvoltageProbeProbeCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.20.1.15 | ProbeCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · ProbeCapabilitiesFlags · read-only · current 0600.0020.0001.0015 This attribute defines the probe capabilities of the voltage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvoltageProbeDiscreteReading | 1.3.6.1.4.1.674.10892.5.4.600.20.1.16 | VoltageDiscreteReadingEnum | RO | 1 | |||||||||||||||||
column · VoltageDiscreteReadingEnum · read-only · current 0600.0020.0001.0016 This attribute defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TamperageProbeTable | 1.3.6.1.4.1.674.10892.5.4.600.30 | NA | |||||||||||||||||||
table · not-accessible · current 0600.0030 This object defines the Amperage Probe Table. | |||||||||||||||||||||
| RamperageProbeTableEntry | 1.3.6.1.4.1.674.10892.5.4.600.30.1 | NA | |||||||||||||||||||
row · not-accessible · current 0600.0030.0001 This object defines the Amperage Probe Table Entry. | |||||||||||||||||||||
| CamperageProbechassisIndex | 1.3.6.1.4.1.674.10892.5.4.600.30.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0030.0001.0001 This attribute defines the index (one based) of the system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeIndex | 1.3.6.1.4.1.674.10892.5.4.600.30.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0030.0001.0002 This attribute defines the index (one based) of the amperage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.30.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0600.0030.0001.0003 This attribute defines the state capabilities of the amperage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeStateSettings | 1.3.6.1.4.1.674.10892.5.4.600.30.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 0600.0030.0001.0004 This attribute defines the state settings of the amperage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeStatus | 1.3.6.1.4.1.674.10892.5.4.600.30.1.5 | StatusProbeEnum | RO | 3 | |||||||||||||||||
column · StatusProbeEnum · read-only · current 0600.0030.0001.0005 This attribute defines the probe status of the amperage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeReading | 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 | Signed32BitRange | RO | 224 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0030.0001.0006 This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyAmps or amperageProbeTypeIsSystemAmps, the value returned for this attribute is the power usage that the probe is reading in tenths of Amps. When the value for amperageProbeType is amperageProbeTypeIsPowerSupplyWatts or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the power usage that the probe is reading in Watts. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, amperageProbeTypeIsPowerSupplyAmps, amperageProbeTypeIsPowerSupplyWatts, amperageProbeTypeIsSystemAmps or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeType | 1.3.6.1.4.1.674.10892.5.4.600.30.1.7 | AmperageProbeTypeEnum | RO | 26 | |||||||||||||||||
column · AmperageProbeTypeEnum · read-only · current 0600.0030.0001.0007 This attribute defines the type of the amperage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeLocationName | 1.3.6.1.4.1.674.10892.5.4.600.30.1.8 | String64 | RO | System Board Pwr Consumption | |||||||||||||||||
column · String64 · read-only · current 0600.0030.0001.0008 This attribute defines the location of the amperage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeUpperNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.600.30.1.9 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0030.0001.0009 This attribute defines the upper nonrecoverable threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. | |||||||||||||||||||||
| CamperageProbeUpperCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.30.1.10 | Signed32BitRange | RO | 1218 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0030.0001.0010 This attribute defines the upper critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeUpperNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.30.1.11 | Signed32BitRange | RO | 1106 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0030.0001.0011 This attribute defines the upper noncritical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeLowerNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.30.1.12 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0030.0001.0012 This attribute defines the lower noncritical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. | |||||||||||||||||||||
| CamperageProbeLowerCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.600.30.1.13 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0030.0001.0013 This attribute defines the lower critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. | |||||||||||||||||||||
| CamperageProbeLowerNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.600.30.1.14 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0600.0030.0001.0014 This attribute defines the lower nonrecoverable threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. | |||||||||||||||||||||
| CamperageProbeProbeCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.30.1.15 | ProbeCapabilitiesFlags | RO | 5 | |||||||||||||||||
column · ProbeCapabilitiesFlags · read-only · current 0600.0030.0001.0015 This attribute defines the probe capabilities of the amperage probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CamperageProbeDiscreteReading | 1.3.6.1.4.1.674.10892.5.4.600.30.1.16 | AmperageDiscreteReadingEnum | RO | ||||||||||||||||||
column · AmperageDiscreteReadingEnum · read-only · current 0600.0030.0001.0016 This attribute defines the reading for an amperage probe of type amperageProbeTypeIsDiscrete. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. | |||||||||||||||||||||
| TsystemBatteryTable | 1.3.6.1.4.1.674.10892.5.4.600.50 | NA | |||||||||||||||||||
table · not-accessible · current 0600.0050 This object defines the System Battery Table. | |||||||||||||||||||||
| RsystemBatteryTableEntry | 1.3.6.1.4.1.674.10892.5.4.600.50.1 | NA | |||||||||||||||||||
row · not-accessible · current 0600.0050.0001 This object defines the System Battery Table Entry. | |||||||||||||||||||||
| CsystemBatteryChassisIndex | 1.3.6.1.4.1.674.10892.5.4.600.50.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0050.0001.0001 This attribute defines the index (one based) of the system chassis that contains the battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemBatteryIndex | 1.3.6.1.4.1.674.10892.5.4.600.50.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0600.0050.0001.0002 This attribute defines the index (one based) of the battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemBatteryStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.50.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0600.0050.0001.0003 This attribute defines the state capabilities of the battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemBatteryStateSettings | 1.3.6.1.4.1.674.10892.5.4.600.50.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 0600.0050.0001.0004 This attribute defines the state settings of the battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemBatteryStatus | 1.3.6.1.4.1.674.10892.5.4.600.50.1.5 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 0600.0050.0001.0005 This attribute defines the status of the battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemBatteryReading | 1.3.6.1.4.1.674.10892.5.4.600.50.1.6 | SystemBatteryReadingFlags | RO | 4 | |||||||||||||||||
column · SystemBatteryReadingFlags · read-only · current 0600.0050.0001.0006 This attribute defines the reading of the battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CsystemBatteryLocationName | 1.3.6.1.4.1.674.10892.5.4.600.50.1.7 | String64 | RO | System Board CMOS Battery | |||||||||||||||||
column · String64 · read-only · current 0600.0050.0001.0007 This attribute defines the location of the battery. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TpowerUsageTable | 1.3.6.1.4.1.674.10892.5.4.600.60 | NA | |||||||||||||||||||
table · not-accessible · current 0600.0060 This object defines the Power Usage Table. | |||||||||||||||||||||
| RpowerUsageTableEntry | 1.3.6.1.4.1.674.10892.5.4.600.60.1 | NA | |||||||||||||||||||
row · not-accessible · current 0600.0060.0001 This object defines the Power Usage Table Entry. | |||||||||||||||||||||
| CpowerUsageChassisIndex | 1.3.6.1.4.1.674.10892.5.4.600.60.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0600.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CpowerUsageIndex | 1.3.6.1.4.1.674.10892.5.4.600.60.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0600.0060.0001.0002 This attribute defines the index (one based) of the power usage information. | |||||||||||||||||||||
| CpowerUsageStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.60.1.3 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0600.0060.0001.0003 This attribute defines the state capabilities of the power usage information. | |||||||||||||||||||||
| CpowerUsageStateSettings | 1.3.6.1.4.1.674.10892.5.4.600.60.1.4 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0600.0060.0001.0004 This attribute defines the state settings of the power usage information. | |||||||||||||||||||||
| CpowerUsageStatus | 1.3.6.1.4.1.674.10892.5.4.600.60.1.5 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0600.0060.0001.0005 This attribute defines the status of the power usage information. | |||||||||||||||||||||
| CpowerUsageEntityName | 1.3.6.1.4.1.674.10892.5.4.600.60.1.6 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0600.0060.0001.0006 This attribute defines the name of the entity associated with this power usage information. | |||||||||||||||||||||
| CpowerUsageCumulativeWattage | 1.3.6.1.4.1.674.10892.5.4.600.60.1.7 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0007 This attribute defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute. | |||||||||||||||||||||
| CpowerUsageCumulativeWattageStartDateName | 1.3.6.1.4.1.674.10892.5.4.600.60.1.8 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0600.0060.0001.0008 This attribute defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute. | |||||||||||||||||||||
| CpowerUsagePeakWatts | 1.3.6.1.4.1.674.10892.5.4.600.60.1.9 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0009 This attribute defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. | |||||||||||||||||||||
| CpowerUsagePeakWattsStartDateName | 1.3.6.1.4.1.674.10892.5.4.600.60.1.10 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0600.0060.0001.0010 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute. | |||||||||||||||||||||
| CpowerUsagePeakWattsReadingDateName | 1.3.6.1.4.1.674.10892.5.4.600.60.1.11 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0600.0060.0001.0011 This attribute defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured. | |||||||||||||||||||||
| CpowerUsagePeakAmps | 1.3.6.1.4.1.674.10892.5.4.600.60.1.12 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0012 This attribute defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute. | |||||||||||||||||||||
| CpowerUsagePeakAmpsStartDateName | 1.3.6.1.4.1.674.10892.5.4.600.60.1.13 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0600.0060.0001.0013 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute. | |||||||||||||||||||||
| CpowerUsagePeakAmpsReadingDateName | 1.3.6.1.4.1.674.10892.5.4.600.60.1.14 | DateName | RO | ||||||||||||||||||
column · DateName · read-only · current 0600.0060.0001.0014 This attribute defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured. | |||||||||||||||||||||
| CpowerUsageIdlePower | 1.3.6.1.4.1.674.10892.5.4.600.60.1.15 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0015 This attribute defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. | |||||||||||||||||||||
| CpowerUsageMaxPotentialPower | 1.3.6.1.4.1.674.10892.5.4.600.60.1.16 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0016 This attribute defines the system maximum potential power (in Watts). This is the maximum power the system can consume based on the current hardware configuration. | |||||||||||||||||||||
| CpowerUsagePowerCapCapabilities | 1.3.6.1.4.1.674.10892.5.4.600.60.1.17 | PowerCapCapabilitiesFlags | RO | ||||||||||||||||||
column · PowerCapCapabilitiesFlags · read-only · current 0600.0060.0001.0017 This attribute defines the system power cap capabilities. | |||||||||||||||||||||
| CpowerUsagePowerCapSetting | 1.3.6.1.4.1.674.10892.5.4.600.60.1.18 | PowerCapSettingEnum | RO | ||||||||||||||||||
column · PowerCapSettingEnum · read-only · current 0600.0060.0001.0018 This attribute defines the system power cap setting. | |||||||||||||||||||||
| CpowerUsagePowerCapValue | 1.3.6.1.4.1.674.10892.5.4.600.60.1.19 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0019 This attribute defines the system power cap value (in Watts). | |||||||||||||||||||||
| CpowerUsageInstantaneousHeadroom | 1.3.6.1.4.1.674.10892.5.4.600.60.1.20 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0020 This attribute defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. | |||||||||||||||||||||
| CpowerUsagePeakHeadroom | 1.3.6.1.4.1.674.10892.5.4.600.60.1.21 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 0600.0060.0001.0021 This attribute defines the system peak headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus peak power draw. | |||||||||||||||||||||
| NthermalGroup | 1.3.6.1.4.1.674.10892.5.4.700 | ||||||||||||||||||||
| TcoolingUnitTable | 1.3.6.1.4.1.674.10892.5.4.700.10 | NA | |||||||||||||||||||
table · not-accessible · current 0700.0010 This object defines the Cooling Unit Table. | |||||||||||||||||||||
| RcoolingUnitTableEntry | 1.3.6.1.4.1.674.10892.5.4.700.10.1 | NA | |||||||||||||||||||
row · not-accessible · current 0700.0010.0001 This object defines the Cooling Unit Table Entry. | |||||||||||||||||||||
| CcoolingUnitchassisIndex | 1.3.6.1.4.1.674.10892.5.4.700.10.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0700.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CcoolingUnitIndex | 1.3.6.1.4.1.674.10892.5.4.700.10.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0700.0010.0001.0002 This attribute defines the index (one based) of the cooling unit. | |||||||||||||||||||||
| CcoolingUnitStateCapabilties | 1.3.6.1.4.1.674.10892.5.4.700.10.1.3 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0700.0010.0001.0003 This attribute defines the state capabilities of the cooling unit. | |||||||||||||||||||||
| CcoolingUnitStateSettings | 1.3.6.1.4.1.674.10892.5.4.700.10.1.4 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 0700.0010.0001.0004 This attribute defines the state settings of the cooling unit. | |||||||||||||||||||||
| CcoolingUnitRedundancyStatus | 1.3.6.1.4.1.674.10892.5.4.700.10.1.5 | StatusRedundancyEnum | RO | ||||||||||||||||||
column · StatusRedundancyEnum · read-only · current 0700.0010.0001.0005 This attribute defines the redundancy status of the cooling unit. | |||||||||||||||||||||
| CcoolingDeviceCountForRedundancy | 1.3.6.1.4.1.674.10892.5.4.700.10.1.6 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 0700.0010.0001.0006 This attribute defines the total number of cooling devices required for this cooling unit to have full redundancy. | |||||||||||||||||||||
| CcoolingUnitName | 1.3.6.1.4.1.674.10892.5.4.700.10.1.7 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 0700.0010.0001.0007 This attribute defines the name of the cooling unit. | |||||||||||||||||||||
| CcoolingUnitStatus | 1.3.6.1.4.1.674.10892.5.4.700.10.1.8 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 0700.0010.0001.0008 This attribute defines the status of the cooling unit. | |||||||||||||||||||||
| TcoolingDeviceTable | 1.3.6.1.4.1.674.10892.5.4.700.12 | NA | |||||||||||||||||||
table · not-accessible · current 0700.0012 This object defines the Cooling Device Table. | |||||||||||||||||||||
| RcoolingDeviceTableEntry | 1.3.6.1.4.1.674.10892.5.4.700.12.1 | NA | |||||||||||||||||||
row · not-accessible · current 0700.0012.0001 This object defines the Cooling Device Table Entry. | |||||||||||||||||||||
| CcoolingDevicechassisIndex | 1.3.6.1.4.1.674.10892.5.4.700.12.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0700.0012.0001.0001 This attribute defines the index (one based) of the associated system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceIndex | 1.3.6.1.4.1.674.10892.5.4.700.12.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0700.0012.0001.0002 This attribute defines the index (one based) of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.700.12.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0700.0012.0001.0003 This attribute defines the state capabilities of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceStateSettings | 1.3.6.1.4.1.674.10892.5.4.700.12.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 0700.0012.0001.0004 This attribute defines the state settings of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceStatus | 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 | StatusProbeEnum | RO | 3 | |||||||||||||||||
column · StatusProbeEnum · read-only · current 0700.0012.0001.0005 This attribute defines the probe status of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceReading | 1.3.6.1.4.1.674.10892.5.4.700.12.1.6 | Signed32BitRange | RO | 9116 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceType | 1.3.6.1.4.1.674.10892.5.4.700.12.1.7 | CoolingDeviceTypeEnum | RO | 3 | |||||||||||||||||
column · CoolingDeviceTypeEnum · read-only · current 0700.0012.0001.0007 This attribute defines the type of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceLocationName | 1.3.6.1.4.1.674.10892.5.4.700.12.1.8 | String64 | RO | FAN1A | |||||||||||||||||
column · String64 · read-only · current 0700.0012.0001.0008 This attribute defines the location name of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceUpperNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.700.12.1.9 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0012.0001.0009 This attribute defines the upper nonrecoverable threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types. | |||||||||||||||||||||
| CcoolingDeviceUpperCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.12.1.10 | Signed32BitRange | RO | 21500 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0012.0001.0010 This attribute defines the upper critical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceUpperNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.12.1.11 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0012.0001.0011 This attribute defines the upper noncritical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types. | |||||||||||||||||||||
| CcoolingDeviceLowerNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.12.1.12 | Signed32BitRange | RO | 840 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0012.0001.0012 This attribute defines the lower noncritical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceLowerCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.12.1.13 | Signed32BitRange | RO | 86 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0012.0001.0013 This attribute defines the lower critical threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceLowerNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.700.12.1.14 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0012.0001.0014 This attribute defines the lower nonrecoverable threshold of the cooling device. The value is an integer representing fan speed in revolutions per minute (RPM). It is not applicable to OFF/ON type cooling devices or non-cooling device types. | |||||||||||||||||||||
| CcoolingDevicecoolingUnitIndexReference | 1.3.6.1.4.1.674.10892.5.4.700.12.1.15 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0700.0012.0001.0015 This attribute defines the index to the associated cooling unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceSubType | 1.3.6.1.4.1.674.10892.5.4.700.12.1.16 | CoolingDeviceSubTypeEnum | RO | 5 | |||||||||||||||||
column · CoolingDeviceSubTypeEnum · read-only · current 0700.0012.0001.0016 This attribute defines the subtype of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceProbeCapabilities | 1.3.6.1.4.1.674.10892.5.4.700.12.1.17 | ProbeCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · ProbeCapabilitiesFlags · read-only · current 0700.0012.0001.0017 This attribute defines the probe capabilities of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingDeviceDiscreteReading | 1.3.6.1.4.1.674.10892.5.4.700.12.1.18 | CoolingDeviceDiscreteReadingEnum | RO | ||||||||||||||||||
column · CoolingDeviceDiscreteReadingEnum · read-only · current 0700.0012.0001.0018 This attribute defines the reading for a cooling device of type coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the discrete reading for the cooling device. | |||||||||||||||||||||
| CcoolingDeviceFQDD | 1.3.6.1.4.1.674.10892.5.4.700.12.1.19 | FQDDString | RO | Fan.Embedded.1A | |||||||||||||||||
column · FQDDString · read-only · current 0700.0012.0001.0019 Fully qualified device descriptor (FQDD) of the cooling device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TtemperatureProbeTable | 1.3.6.1.4.1.674.10892.5.4.700.20 | NA | |||||||||||||||||||
table · not-accessible · current 0700.0020 This object defines the Temperature Probe Table. | |||||||||||||||||||||
| RtemperatureProbeTableEntry | 1.3.6.1.4.1.674.10892.5.4.700.20.1 | NA | |||||||||||||||||||
row · not-accessible · current 0700.0020.0001 This object defines the Temperature Probe Table Entry. | |||||||||||||||||||||
| CtemperatureProbechassisIndex | 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0700.0020.0001.0001 This attribute defines the index (one based) of the associated system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeIndex | 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 0700.0020.0001.0002 This attribute defines the index (one based) of the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 0700.0020.0001.0003 This attribute defines the state capabilities of the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeStateSettings | 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 0700.0020.0001.0004 This attribute defines the state settings of the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeStatus | 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 | StatusProbeEnum | RO | 3 | |||||||||||||||||
column · StatusProbeEnum · read-only · current 0700.0020.0001.0005 This attribute defines the probe status of the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeReading | 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 | Signed32BitRange | RO | 170 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeType | 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 | TemperatureProbeTypeEnum | RO | 3 | |||||||||||||||||
column · TemperatureProbeTypeEnum · read-only · current 0700.0020.0001.0007 This attribute defines the type of the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeLocationName | 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 | String64 | RO | Inlet Temp | |||||||||||||||||
column · String64 · read-only · current 0700.0020.0001.0008 This attribute defines the location name of the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeUpperNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade. | |||||||||||||||||||||
| CtemperatureProbeUpperCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 | Signed32BitRange | RO | 270 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0020.0001.0010 This attribute defines the upper critical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeUpperNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 | Signed32BitRange | RO | 260 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0020.0001.0011 This attribute defines the upper noncritical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeLowerNonCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 | Signed32BitRange | RO | 30 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0020.0001.0012 This attribute defines the lower noncritical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeLowerCriticalThreshold | 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 | Signed32BitRange | RO | -70 | |||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeLowerNonRecoverableThreshold | 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 | Signed32BitRange | RO | ||||||||||||||||||
column · Signed32BitRange · read-only · current 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the temperature probe. The value is an integer representing the temperature of the threshold in tenths of degrees Centigrade. | |||||||||||||||||||||
| CtemperatureProbeProbeCapabilities | 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 | ProbeCapabilitiesFlags | RO | 15 | |||||||||||||||||
column · ProbeCapabilitiesFlags · read-only · current 0700.0020.0001.0015 This attribute defines the probe capabilities of the temperature probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureProbeDiscreteReading | 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 | TemperatureDiscreteReadingEnum | RO | ||||||||||||||||||
column · TemperatureDiscreteReadingEnum · read-only · current 0700.0020.0001.0016 This attribute defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. | |||||||||||||||||||||
| NdeviceGroup | 1.3.6.1.4.1.674.10892.5.4.1100 | ||||||||||||||||||||
| TprocessorDeviceTable | 1.3.6.1.4.1.674.10892.5.4.1100.30 | NA | |||||||||||||||||||
table · not-accessible · current 1100.0030 This object defines the Processor Device Table. | |||||||||||||||||||||
| RprocessorDeviceTableEntry | 1.3.6.1.4.1.674.10892.5.4.1100.30.1 | NA | |||||||||||||||||||
row · not-accessible · current 1100.0030.0001 This object defines the Processor Device Table Entry. | |||||||||||||||||||||
| CprocessorDevicechassisIndex | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 1100.0030.0001.0001 This attribute defines the index (one based) of the associated system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceIndex | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 1100.0030.0001.0002 This attribute defines the index (one based) of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 1100.0030.0001.0003 This attribute defines the state capabilities of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStateSettings | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 1100.0030.0001.0004 This attribute defines the state settings of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatus | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 1100.0030.0001.0005 This attribute defines the status of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceType | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 | ProcessorDeviceType | RO | 3 | |||||||||||||||||
column · ProcessorDeviceType · read-only · current 1100.0030.0001.0007 This attribute defines the type of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceManufacturerName | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 | String64 | RO | AMD | |||||||||||||||||
column · String64 · read-only · current 1100.0030.0001.0008 This attribute defines the name of the manufacturer of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatusState | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 | ProcessorDeviceStatusState | RO | 3 | |||||||||||||||||
column · ProcessorDeviceStatusState · read-only · current 1100.0030.0001.0009 This attribute defines the status state of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceFamily | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 | ProcessorDeviceFamily | RO | 107 | |||||||||||||||||
column · ProcessorDeviceFamily · read-only · current 1100.0030.0001.0010 This attribute defines the family of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceMaximumSpeed | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 | Unsigned32BitRange | RO | 3900 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0030.0001.0011 This attribute defines the maximum speed of the processor device in MHz. Zero indicates the maximum speed is unknown. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceCurrentSpeed | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 | Unsigned32BitRange | RO | 2250 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0030.0001.0012 This attribute defines the current speed of the processor device in MHz. Zero indicates the current speed is unknown. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceExternalClockSpeed | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 | Unsigned32BitRange | RO | 16000 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0030.0001.0013 This attribute defines the speed of the external clock for the processor device in MHz. Zero indicates the external clock speed is unknown. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceVoltage | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 | Signed32BitRange | RO | 14600 | |||||||||||||||||
column · Signed32BitRange · read-only · current 1100.0030.0001.0014 This attribute defines the voltage powering the processor device in millivolts. Zero indicates the voltage is unknown. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceVersionName | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 | String64 | RO | Model 49 Stepping 0 | |||||||||||||||||
column · String64 · read-only · current 1100.0030.0001.0016 This attribute defines the version of the processor device. On some systems, this value contains the brand and stepping information; on other systems, this value contains the model and stepping information. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceCoreCount | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 | Unsigned32BitRange | RO | 64 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0030.0001.0017 This attribute defines the number of processor cores detected for the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceCoreEnabledCount | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 | Unsigned32BitRange | RO | 64 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0030.0001.0018 This attribute defines the number of processor cores enabled for the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceThreadCount | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 | Unsigned32BitRange | RO | 64 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0030.0001.0019 This attribute defines the number of processor threads detected for the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceCharacteristics | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 | Unsigned16BitRange | RO | 4 | |||||||||||||||||
column · Unsigned16BitRange · read-only · current 1100.0030.0001.0020 This attribute defines characteristics of the
processor device. This attribute is a bit field where a bit has the meaning
defined below when set to 1 (one).
NOTE: Bits 2-15 need to be examined in the context of bit 1.
If bit 1 is set, the processor charactistics are unknown and bits 2-15 cannot
be used to determine if the functions associated with the bits are supported.
Bit
Position Meaning if Set
-------- --------------
Bit 0 Reserved
Bit 1 Unknown
Bit 2 64-bit capable
Bit 3-15 ReservedExample values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceExtendedCapabilities | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 | Unsigned16BitRange | RO | 29 | |||||||||||||||||
column · Unsigned16BitRange · read-only · current 1100.0030.0001.0021 This attribute defines extended capabilities of the
processor device. This attribute is a bit field where a bit has the meaning
defined below when set to 1 (one).
Bit
Position Meaning if Set
-------- --------------
Bit 0 Virtualization Technology (VT) supported
Bit 2 eXecute Disable (XD) supported
Bit 3 Hyper-Threading (HT) supported
Bit 4 Turbo Mode supportedExample values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceExtendedSettings | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 | Unsigned16BitRange | RO | 20 | |||||||||||||||||
column · Unsigned16BitRange · read-only · current 1100.0030.0001.0022 This attribute defines extended settings of the
processor device. This attribute is a bit field where a bit has the meaning
defined below when set to 1 (one).
Bit
Position Meaning if Set
-------- --------------
Bit 0 Virtualization Technology (VT) enabled
Bit 2 eXecute Disable (XD) enabled
Bit 3 Hyper-Threading (HT) enabled
Bit 4 Turbo Mode enabledExample values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceBrandName | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 | String64 | RO | AMD EPYC 7742 64-Core Processor | |||||||||||||||||
column · String64 · read-only · current 1100.0030.0001.0023 This attribute defines the brand of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceFQDD | 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 | FQDDString | RO | CPU.Socket.2 | |||||||||||||||||
column · FQDDString · read-only · current 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TprocessorDeviceStatusTable | 1.3.6.1.4.1.674.10892.5.4.1100.32 | NA | |||||||||||||||||||
table · not-accessible · current 1100.0032 This object defines the Processor Device Status Table. | |||||||||||||||||||||
| RprocessorDeviceStatusTableEntry | 1.3.6.1.4.1.674.10892.5.4.1100.32.1 | NA | |||||||||||||||||||
row · not-accessible · current 1100.0032.0001 This object defines the Processor Device Status Table Entry. | |||||||||||||||||||||
| CprocessorDeviceStatusChassisIndex | 1.3.6.1.4.1.674.10892.5.4.1100.32.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 1100.0032.0001.0001 This attribute defines the index (one based) of the associated system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatusIndex | 1.3.6.1.4.1.674.10892.5.4.1100.32.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 1100.0032.0001.0002 This attribute defines the index (one based) of the processor device status probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatusStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.1100.32.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 1100.0032.0001.0003 This attribute defines the state capabilities of the processor device status probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatusStateSettings | 1.3.6.1.4.1.674.10892.5.4.1100.32.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 1100.0032.0001.0004 This attribute defines the state settings of the processor device status probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatusStatus | 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 1100.0032.0001.0005 This attribute defines the status of the processor device status probe. This status will be joined into the processorDeviceStatus attribute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatusReading | 1.3.6.1.4.1.674.10892.5.4.1100.32.1.6 | ProcessorDeviceStatusReadingFlags | RO | 128 | |||||||||||||||||
column · ProcessorDeviceStatusReadingFlags · read-only · current 1100.0032.0001.0006 This attribute defines the reading of the processor device status probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CprocessorDeviceStatusLocationName | 1.3.6.1.4.1.674.10892.5.4.1100.32.1.7 | String64 | RO | CPU0 Status | |||||||||||||||||
column · String64 · read-only · current 1100.0032.0001.0007 This attribute defines the location name of the processor device status probe. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmemoryDeviceTable | 1.3.6.1.4.1.674.10892.5.4.1100.50 | NA | |||||||||||||||||||
table · not-accessible · current 1100.0050 This object defines the Memory Device Table. | |||||||||||||||||||||
| RmemoryDeviceTableEntry | 1.3.6.1.4.1.674.10892.5.4.1100.50.1 | NA | |||||||||||||||||||
row · not-accessible · current 1100.0050.0001 This object defines the Memory Device Table Entry. | |||||||||||||||||||||
| CmemoryDevicechassisIndex | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.1 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 1100.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceIndex | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.2 | ObjectRange | RO | 1 | |||||||||||||||||
column · ObjectRange · read-only · current 1100.0050.0001.0002 This attribute defines the index (one based) of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.3 | StateCapabilitiesFlags | RO | 0 | |||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 1100.0050.0001.0003 This attribute defines the state capabilities of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceStateSettings | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.4 | StateSettingsFlags | RO | 2 | |||||||||||||||||
column · StateSettingsFlags · read-only · current 1100.0050.0001.0004 This attribute defines the state settings of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceStatus | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current 1100.0050.0001.0005 This attribute defines the status of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceType | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.7 | MemoryDeviceTypeEnum | RO | 26 | |||||||||||||||||
column · MemoryDeviceTypeEnum · read-only · current 1100.0050.0001.0007 This attribute defines the type of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceLocationName | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8 | String64 | RO | DIMM.Socket.B3 | |||||||||||||||||
column · String64 · read-only · current 1100.0050.0001.0008 This attribute defines the location of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceBankLocationName | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.10 | String64 | RO | B | |||||||||||||||||
column · String64 · read-only · current 1100.0050.0001.0010 This attribute defines the location of the bank for the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceSize | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 | Unsigned32BitRange | RO | 67108864 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceSpeed | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.15 | Unsigned32BitRange | RO | 3200 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0050.0001.0015 This attribute defines the maximum capable speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceManufacturerName | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.21 | String64 | RO | Micron Technology | |||||||||||||||||
column · String64 · read-only · current 1100.0050.0001.0021 This attribute defines the manufacturer of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDevicePartNumberName | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.22 | String64 | RO | 36ASF8G72PZ-3G2B2 | |||||||||||||||||
column · String64 · read-only · current 1100.0050.0001.0022 This attribute defines the manufacturer's part number for the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceSerialNumberName | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.23 | String64 | RO | 344DDA62 | |||||||||||||||||
column · String64 · read-only · current 1100.0050.0001.0023 This attribute defines the serial number of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceFQDD | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.26 | FQDDString | RO | DIMM.Socket.B3 | |||||||||||||||||
column · FQDDString · read-only · current 1100.0050.0001.0026 Fully qualified device descriptor (FQDD) of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceCurrentOperatingSpeed | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.27 | Unsigned32BitRange | RO | 3200 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0050.0001.0027 This attribute defines the current operating speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceTechnology | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.28 | MemoryTechnologyEnum | RO | 3 | |||||||||||||||||
column · MemoryTechnologyEnum · read-only · current 1100.0050.0001.0028 This attribute defines the type or technology of the memory device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceVolatileSize | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.29 | Unsigned32BitRange | RO | 0 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0050.0001.0029 This attribute defines the volatile size of the memory device in MBs. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceNonVolatilesSize | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.30 | Unsigned32BitRange | RO | 0 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0050.0001.0030 This attribute defines the Non Volatile size of the memory device in MBs. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceCacheSize | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.31 | Unsigned32BitRange | RO | 0 | |||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0050.0001.0031 This attribute defines the Cache size of the memory device in MBs. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CmemoryDeviceRemainingRatedWriteEndurance | 1.3.6.1.4.1.674.10892.5.4.1100.50.1.32 | MemoryPropertyEnum | RO | 255 | |||||||||||||||||
column · MemoryPropertyEnum · read-only · current 1100.0050.0001.0032 This attribute defines the percent of remaining life for the memory device Example values from LibreNMS test devices
| |||||||||||||||||||||
| TpCIDeviceTable | 1.3.6.1.4.1.674.10892.5.4.1100.80 | NA | |||||||||||||||||||
table · not-accessible · current 1100.0080 This object defines the PCI Device Table. | |||||||||||||||||||||
| RpCIDeviceTableEntry | 1.3.6.1.4.1.674.10892.5.4.1100.80.1 | NA | |||||||||||||||||||
row · not-accessible · current 1100.0080.0001 This object defines the PCI Device Table Entry. | |||||||||||||||||||||
| CpCIDevicechassisIndex | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 1100.0080.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CpCIDeviceIndex | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 1100.0080.0001.0002 This attribute defines the index (one based) of the PCI device. | |||||||||||||||||||||
| CpCIDeviceStateCapabilities | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.3 | StateCapabilitiesFlags | RO | ||||||||||||||||||
column · StateCapabilitiesFlags · read-only · current 1100.0080.0001.0003 This attribute defines the state capabilities of the PCI device. | |||||||||||||||||||||
| CpCIDeviceStateSettings | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.4 | StateSettingsFlags | RO | ||||||||||||||||||
column · StateSettingsFlags · read-only · current 1100.0080.0001.0004 This attribute defines the state settings of the PCI device. | |||||||||||||||||||||
| CpCIDeviceStatus | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.5 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 1100.0080.0001.0005 This attribute defines the status of the PCI device. | |||||||||||||||||||||
| CpCIDeviceDataBusWidth | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.7 | Unsigned32BitRange | RO | ||||||||||||||||||
column · Unsigned32BitRange · read-only · current 1100.0080.0001.0007 This attribute defines the width of the data bus
of the PCI device. This attribute contains an enumeration value.
The possible values and their meanings are defined below.
Value Meaning
---------- --------------
0x00000001 Other
0x00000002 Unknown
0x00000003 8 bit
0x00000004 16 bit
0x00000005 32 bit
0x00000006 64 bit
0x00000007 128 bit
0x00000008 1x or x1
0x00000009 2x or x2
0x0000000A 4x or x4
0x0000000B 8x or x8
0x0000000C 12x or x12
0x0000000D 16x or x16
0x0000000E 32x or x32 | |||||||||||||||||||||
| CpCIDeviceManufacturerName | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.8 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 1100.0080.0001.0008 This attribute defines the name of the manufacturer of the PCI device. | |||||||||||||||||||||
| CpCIDeviceDescriptionName | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.9 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 1100.0080.0001.0009 This attribute defines the description of the PCI device. | |||||||||||||||||||||
| CpCIDeviceFQDD | 1.3.6.1.4.1.674.10892.5.4.1100.80.1.12 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current 1100.0080.0001.0012 Fully qualified device descriptor (FQDD) of the PCI device. | |||||||||||||||||||||
| TnetworkDeviceTable | 1.3.6.1.4.1.674.10892.5.4.1100.90 | NA | |||||||||||||||||||
table · not-accessible · current 1100.0090 This object defines the Network Device Table. | |||||||||||||||||||||
| RnetworkDeviceTableEntry | 1.3.6.1.4.1.674.10892.5.4.1100.90.1 | NA | |||||||||||||||||||
row · not-accessible · current 1100.0090.0001 This object defines the Network Device Table Entry. | |||||||||||||||||||||
| CnetworkDeviceChassisIndex | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 1100.0090.0001.0001 This attribute defines the index (one based) of the system chassis that contains the network device. | |||||||||||||||||||||
| CnetworkDeviceIndex | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 1100.0090.0001.0002 This attribute defines the index (one based) of the network device. | |||||||||||||||||||||
| CnetworkDeviceStatus | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.3 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 1100.0090.0001.0003 This attribute defines the status of the network device. | |||||||||||||||||||||
| CnetworkDeviceConnectionStatus | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.4 | NetworkDeviceConnectionStatusEnum | RO | ||||||||||||||||||
column · NetworkDeviceConnectionStatusEnum · read-only · current 1100.0090.0001.0004 This attribute defines the connection status of the network device. | |||||||||||||||||||||
| CnetworkDeviceProductName | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.6 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 1100.0090.0001.0006 This attribute defines the product name of the network device. | |||||||||||||||||||||
| CnetworkDeviceVendorName | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.7 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 1100.0090.0001.0007 This attribute defines the name of the vendor of the network device. | |||||||||||||||||||||
| CnetworkDeviceCurrentMACAddress | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15 | MACAddress | RO | ||||||||||||||||||
column · MACAddress · read-only · current 1100.0090.0001.0015 This attribute defines the current MAC address of the network device. | |||||||||||||||||||||
| CnetworkDevicePermanentMACAddress | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.16 | MACAddress | RO | ||||||||||||||||||
column · MACAddress · read-only · current 1100.0090.0001.0016 This attribute defines the permanent MAC address of the network device. | |||||||||||||||||||||
| CnetworkDevicePCIBusNumber | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.17 | Unsigned8BitRange | RO | ||||||||||||||||||
column · Unsigned8BitRange · read-only · current 1100.0090.0001.0017 This attribute defines the PCI bus number of the network device. | |||||||||||||||||||||
| CnetworkDevicePCIDeviceNumber | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.18 | Unsigned8BitRange | RO | ||||||||||||||||||
column · Unsigned8BitRange · read-only · current 1100.0090.0001.0018 This attribute defines the PCI device number of the network device. | |||||||||||||||||||||
| CnetworkDevicePCIFunctionNumber | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.19 | Unsigned8BitRange | RO | ||||||||||||||||||
column · Unsigned8BitRange · read-only · current 1100.0090.0001.0019 This attribute defines the PCI function number of the network device. | |||||||||||||||||||||
| CnetworkDeviceTOECapabilityFlags | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.23 | NetworkDeviceTOECapabilityFlags | RO | ||||||||||||||||||
column · NetworkDeviceTOECapabilityFlags · read-only · current 1100.0090.0001.0023 This attribute defines the TCP/IP Offload Engine (TOE) capability flags of the network device. | |||||||||||||||||||||
| CnetworkDeviceiSCSICapabilityFlags | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.27 | NetworkDeviceiSCSICapabilityFlags | RO | ||||||||||||||||||
column · NetworkDeviceiSCSICapabilityFlags · read-only · current 1100.0090.0001.0027 This attribute defines the Internet Small Computer System Interface (iSCSI) capability flags of the network device. | |||||||||||||||||||||
| CnetworkDeviceiSCSIEnabled | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.28 | BooleanType | RO | ||||||||||||||||||
column · BooleanType · read-only · current 1100.0090.0001.0028 This attribute defines if iSCSI is enabled for the network device. | |||||||||||||||||||||
| CnetworkDeviceCapabilities | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.29 | NetworkDeviceCapabilitiesFlags | RO | ||||||||||||||||||
column · NetworkDeviceCapabilitiesFlags · read-only · current 1100.0090.0001.0029 This attribute defines the capabilities of the network device. If this value is notSupported(0), the networkDeviceTOECapabilityFlags, networkDeviceiSCSICapabilityFlags and networkDeviceiSCSIEnabled attributes should be used to determine the network device capabilities. If the supported(1) bit is on, this attribute should be used to determine the network device capabilities, and the attributes mentioned above should not be used. NOTE: For a network device on Converged Network Adapter (CNA), this attribute provides capability information for the CNA and not for the network device. For more information read vendor documentation. | |||||||||||||||||||||
| CnetworkDeviceFQDD | 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current 1100.0090.0001.0030 Fully qualified device descriptor (FQDD) of the network device. | |||||||||||||||||||||
| NslotGroup | 1.3.6.1.4.1.674.10892.5.4.1200 | ||||||||||||||||||||
| TsystemSlotTable | 1.3.6.1.4.1.674.10892.5.4.1200.10 | NA | |||||||||||||||||||
table · not-accessible · current 1200.0010 This object defines the System Slot Table. | |||||||||||||||||||||
| RsystemSlotTableEntry | 1.3.6.1.4.1.674.10892.5.4.1200.10.1 | NA | |||||||||||||||||||
row · not-accessible · current 1200.0010.0001 This object defines the System Slot Table Entry. | |||||||||||||||||||||
| CsystemSlotchassisIndex | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 1200.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis. | |||||||||||||||||||||
| CsystemSlotIndex | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 1200.0010.0001.0002 This attribute defines the index (one based) of the system slot. | |||||||||||||||||||||
| CsystemSlotStateCapabilitiesUnique | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.3 | SystemSlotStateCapabilitiesFlags | RO | ||||||||||||||||||
column · SystemSlotStateCapabilitiesFlags · read-only · current 1200.0010.0001.0003 This attribute defines the state capabilities of the system slot. | |||||||||||||||||||||
| CsystemSlotStateSettingsUnique | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.4 | SystemSlotStateSettingsFlags | RO | ||||||||||||||||||
column · SystemSlotStateSettingsFlags · read-only · current 1200.0010.0001.0004 This attribute defines the state settings of the system slot. | |||||||||||||||||||||
| CsystemSlotStatus | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.5 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 1200.0010.0001.0005 This attribute defines the status of the system slot. | |||||||||||||||||||||
| CsystemSlotCurrentUsage | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.6 | SystemSlotUsageEnum | RO | ||||||||||||||||||
column · SystemSlotUsageEnum · read-only · current 1200.0010.0001.0006 This attribute defines the current usage of the system slot. | |||||||||||||||||||||
| CsystemSlotType | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.7 | SystemSlotTypeEnum | RO | ||||||||||||||||||
column · SystemSlotTypeEnum · read-only · current 1200.0010.0001.0007 This attribute defines the type of the system slot. | |||||||||||||||||||||
| CsystemSlotSlotExternalSlotName | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.8 | String64 | RO | ||||||||||||||||||
column · String64 · read-only · current 1200.0010.0001.0008 This attribute defines the name of the external connector name of the system slot. | |||||||||||||||||||||
| CsystemSlotCategory | 1.3.6.1.4.1.674.10892.5.4.1200.10.1.11 | SystemSlotCategoryEnum | RO | ||||||||||||||||||
column · SystemSlotCategoryEnum · read-only · current 1200.0010.0001.0011 This attribute defines the category of the system slot. | |||||||||||||||||||||
| NfruGroup | 1.3.6.1.4.1.674.10892.5.4.2000 | ||||||||||||||||||||
| TfruTable | 1.3.6.1.4.1.674.10892.5.4.2000.10 | NA | |||||||||||||||||||
table · not-accessible · current 2000.0010 This object defines the Field Replaceable Unit table. | |||||||||||||||||||||
| RfruTableEntry | 1.3.6.1.4.1.674.10892.5.4.2000.10.1 | NA | |||||||||||||||||||
row · not-accessible · current 2000.0010.0001 This object defines the Field Replaceable Unit table entry.
| |||||||||||||||||||||
| CfruChassisIndex | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.1 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 2000.0010.0001.0001 This attribute defines the index (one based) of the system chassis containing the field replaceable unit. | |||||||||||||||||||||
| CfruIndex | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.2 | ObjectRange | RO | ||||||||||||||||||
column · ObjectRange · read-only · current 2000.0010.0001.0002 This attribute defines the index (one based) of the field replaceable unit. | |||||||||||||||||||||
| CfruInformationStatus | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.3 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current 2000.0010.0001.0003 This attribute defines the status of the field replaceable unit information. | |||||||||||||||||||||
| CfruManufacturerName | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.6 | OCTET STRING (SIZE (0..64)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..64)) · read-only · current 2000.0010.0001.0006 This attribute defines the manufacturer of the field replaceable unit. | |||||||||||||||||||||
| CfruSerialNumberName | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.7 | OCTET STRING (SIZE (0..64)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..64)) · read-only · current 2000.0010.0001.0007 This attribute defines the serial number of the field replaceable unit. | |||||||||||||||||||||
| CfruPartNumberName | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.8 | OCTET STRING (SIZE (0..64)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..64)) · read-only · current 2000.0010.0001.0008 This attribute defines the part number of the field replaceable unit. | |||||||||||||||||||||
| CfruRevisionName | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.9 | OCTET STRING (SIZE (0..64)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (0..64)) · read-only · current 2000.0010.0001.0009 This attribute defines the revision of the field replaceable unit. | |||||||||||||||||||||
| CfruFQDD | 1.3.6.1.4.1.674.10892.5.4.2000.10.1.12 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current 2000.0010.0001.0012 Fully qualified device descriptor (FQDD) of the field replaceable unit. | |||||||||||||||||||||
| NstorageDetailsGroup | 1.3.6.1.4.1.674.10892.5.5 | ||||||||||||||||||||
| Nsoftware | 1.3.6.1.4.1.674.10892.5.5.1 | ||||||||||||||||||||
| NstorageManagement | 1.3.6.1.4.1.674.10892.5.5.1.20 | ||||||||||||||||||||
| NphysicalDevices | 1.3.6.1.4.1.674.10892.5.5.1.20.130 | ||||||||||||||||||||
| TcontrollerTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed RAID controllers. The number of entries is related to number of RAID controllers discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RcontrollerTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CcontrollerNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1 | INTEGER (1..255) | RO | 1 | |||||||||||||||||
column · INTEGER (1..255) · read-only · current Instance number of this controller entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2 | DisplayString | RO | BOSS-S1 (Embedded) | |||||||||||||||||
column · DisplayString · read-only · current The controller's name as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerRebuildRate | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.7 | INTEGER (0..100) | RO | 255 | |||||||||||||||||
column · INTEGER (0..100) · read-only · current The rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerFWVersion | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8 | DisplayString | RO | 2.6.13.3024 | |||||||||||||||||
column · DisplayString · read-only · current The controller's current firmware version. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCacheSizeInMB | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9 | INTEGER (1..2147483647) | RO | 0 | |||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current The controller's current amount of cache memory in megabytes. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerRollUpStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current Severity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other. 2: Unknown. 3: OK 4: Non-critical 5: Critical. 6: Non-recoverable. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerDriverVersion | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41 | DisplayString | RO | Not Available | |||||||||||||||||
column · DisplayString · read-only · current Currently installed driver version for this controller on the host. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPCISlot | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42 | DisplayString | RO | Embedded | |||||||||||||||||
column · DisplayString · read-only · current The PCI slot on the server where the controller is seated. This data is not reported for embedded or integrated controllers, Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerReconstructRate | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.48 | INTEGER (0..100) | RO | 255 | |||||||||||||||||
column · INTEGER (0..100) · read-only · current The reconstruct rate is the percentage of the controller's resources dedicated to reconstructing a disk group after adding a physical disk or changing the RAID level of a virtual disk residing on the disk group. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPatrolReadRate | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.49 | INTEGER (0..100) | RO | 255 | |||||||||||||||||
column · INTEGER (0..100) · read-only · current The patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerBGIRate | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.50 | INTEGER (0..100) | RO | 255 | |||||||||||||||||
column · INTEGER (0..100) · read-only · current The background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant virtual disk after it is created. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCheckConsistencyRate | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.51 | INTEGER (0..100) | RO | 255 | |||||||||||||||||
column · INTEGER (0..100) · read-only · current The check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPatrolReadMode | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.52 | INTEGER | RO | notSupported(2) | |||||||||||||||||
column · INTEGER · read-only · current Identifies the patrol read mode setting for the controller. Possible values: 1: Not one of the following or could not be determined. 2: Not Supported on this controller. 3: Disabled. 4: Automatic. 5: Manual.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPatrolReadState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.53 | INTEGER | RO | other(1) | |||||||||||||||||
column · INTEGER · read-only · current This property displays the current state of the patrol read process. Possible values: 1: Not one of the following or could not be determined. 2: Patrol read is not running. 3: Patrol read is running.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPersistentHotSpare | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.59 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether hot spare drives would be restored on insertion into the same slot. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSpinDownUnconfiguredDrives | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether un-configured drives would be put in power save mode by the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSpinDownHotSpareDrives | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.61 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether hot spare drives would be put in power save mode by the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSpinDownTimeInterval | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.62 | INTEGER (30..1440) | RO | 0 | |||||||||||||||||
column · INTEGER (30..1440) · read-only · current The duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPreservedCache | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.69 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether preserved cache or pinned cache is present on the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCheckConsistencyMode | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.70 | INTEGER | RO | unsupported(2) | |||||||||||||||||
column · INTEGER · read-only · current The current check consistency mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Normal check consistency operation. 4: Check consistency operation will stop on encountering an error.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCopyBackMode | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71 | INTEGER | RO | unsupported(2) | |||||||||||||||||
column · INTEGER · read-only · current The current copy back mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Disks assigned as spares could revert back to spare status. 4: Data from physical disk participating in a virtual disk could be automatically copied to the assigned hot spare in case former has a predictive failure event. 5: Copyback mode is disabled.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSecurityStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.72 | INTEGER | RO | none(2) | |||||||||||||||||
column · INTEGER · read-only · current The controller's current security/encryption status.. Possible values: 1: The current status could not be determined. 2: Controller is not operating in an encryption mode. 3: Controller is operating in the Local Key Management (LKM) encryption mode.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerEncryptionKeyPresent | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.73 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether encryption key is assigned for the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerEncryptionCapability | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.74 | INTEGER | RO | none(2) | |||||||||||||||||
column · INTEGER · read-only · current The type of encryption supported by the controller. Possible values: 1: Not one of the following. 2: No encryption supported, 3: Local Key Management,
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerLoadBalanceSetting | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.75 | INTEGER | RO | unsupported(2) | |||||||||||||||||
column · INTEGER · read-only · current The ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possible values: 1: Not one of the following. 2: Not supported. 3: Automatic load balancing is active. 4: Load balancing is inactive.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerMaxCapSpeed | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76 | INTEGER | RO | sixGbps(4) | |||||||||||||||||
column · INTEGER · read-only · current The maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSASAddress | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.77 | DisplayString | RO | 0x0 | |||||||||||||||||
column · DisplayString · read-only · current The SAS address of the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78 | FQDDString | RO | AHCI.Integrated.1-1 | |||||||||||||||||
column · FQDDString · read-only · current The controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 | DisplayString | RO | Integrated AHCI controller 1 | |||||||||||||||||
column · DisplayString · read-only · current The controller's friendly FQDD as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerT10PICapability | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80 | INTEGER | RO | notCapable(3) | |||||||||||||||||
column · INTEGER · read-only · current Indicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Capable of supporting T10 PI. 3: Not capable of supporting T10 PI.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerRAID10UnevenSpansSupported | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.81 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether uneven spans for RAID 10 virtual disk is supported on the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerEnhancedAutoImportForeignConfigMode | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.82 | INTEGER | RO | notSupported(2) | |||||||||||||||||
column · INTEGER · read-only · current Indicates the status of enhanced auto-import of foreign configuration property of the controller. 1: Not one of the following. 2: Not Supported. 3: Disabled. 4: Enabled.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerBootModeSupported | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.83 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether headless boot mode settings are supported on the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerBootMode | 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.84 | INTEGER | RO | notApplicable(1) | |||||||||||||||||
column · INTEGER · read-only · current Indicates the boot mode of the controller. Possible values: 1: Not applicable for this controller. 2: User mode: User interaction required for all boot messages (not applicable for uEFI environments). 3: Continue Boot On Error. User interaction only required for critical messages. 4: Headless Mode Continue On Error. User interaction is not required. Controller boot may halt on Error. 5: Headless Safe Mode. Controller shall boot to safe mode on critical errors.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TenclosureTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed enclosures/backplanes. The number of entries is related to number of internal backplane(s) discovered in the system and external storage enclosure(s) attached to the system.. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the enclosure table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CenclosureNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.1 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current Instance number of this enclossre/backplane. | |||||||||||||||||||||
| CenclosureName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The enclosure/backplane's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current state of this enclosure/backplane. Possible states: 1: The current state could not be determined. 2: The enclosure is operating normally. 3: The enclosure has encountered a hardware problem or is not responding. 4: The enclosure is no longer connected to the controller or there exists a problem communicating to the enclosure. 5: The enclosure is unstable.
| |||||||||||||||||||||
| CenclosureServiceTag | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.8 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Enclosure identification used when consulting customer support. | |||||||||||||||||||||
| CenclosureAssetTag | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.9 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The asset tag information for the enclosure. | |||||||||||||||||||||
| CenclosureConnectedPort | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.19 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The port on the controller to which the storage enclosure is connected. | |||||||||||||||||||||
| CenclosureRollUpStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.23 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current Severity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical. 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.24 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the enclosure/backplane.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureFirmwareVersion | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.26 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The firmware information for the enclosure/backplane. | |||||||||||||||||||||
| CenclosureSASAddress | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.30 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The SAS address of the enclosure/backplane. | |||||||||||||||||||||
| CenclosureDriveCount | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.31 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current The number of disks present in the enclosure/backplane. | |||||||||||||||||||||
| CenclosureTotalSlots | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.32 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current The total physical drive slots in a storage enclosure or server backplane. | |||||||||||||||||||||
| CenclosureFanCount | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.40 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The number of fans present in the storage enclosure. | |||||||||||||||||||||
| CenclosurePSUCount | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.41 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The number of Power Supply Units (PSU) present in the storage enclosure. | |||||||||||||||||||||
| CenclosureEMMCount | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.42 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The number of Enclosure Management Modules (EMM) present in the storage enclosure. | |||||||||||||||||||||
| CenclosureTempProbeCount | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.43 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The number of temperature sensing devices present in the storage enclosure. | |||||||||||||||||||||
| CenclosureRedundantPath | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.44 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Indicates whether the controller has multiply paths to reach the storage enclosure. | |||||||||||||||||||||
| CenclosurePosition | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.45 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The possition of the storage enclosure within a daisy chain. | |||||||||||||||||||||
| CenclosureBackplaneBayID | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.46 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The unique bay ID of the backplane. | |||||||||||||||||||||
| CenclosureFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.47 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current The enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.48 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The enclosure/backplane's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| CenclosureType | 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.49 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The protocol supported by the backplane. Possible states: 1: Not one of the following or could not be determined. 2: Not applicable (i.e. object is not a backplane). 3: Supports SAS/SATA. 4: Supports PCIe. 5: Both SAS/SATA and PCIe.
| |||||||||||||||||||||
| TphysicalDiskTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed physical disks. The number of entries is related to number of physical Disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RphysicalDiskTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the physical Disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CphysicalDiskNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 | INTEGER (1..1000000000) | RO | 1 | |||||||||||||||||
column · INTEGER (1..1000000000) · read-only · current Instance number of this physical disk entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 | DisplayString | RO | SSD 0 | |||||||||||||||||
column · DisplayString · read-only · current The physical disk's name as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufacturer | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3 | DisplayString | RO | MICRON | |||||||||||||||||
column · DisplayString · read-only · current The name of the physical disk's manufacturer. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4 | INTEGER | RO | online(3) | |||||||||||||||||
column · INTEGER · read-only · current The current state of this physical disk. Possible states: 1: The current state could not be determined. 2: The physical disk is available for use, but no RAID configuration has been assigned. 3: A RAID configuration has been assigned to the physical disk. 4: The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: The physical disk is not available to the RAID controller. 6: The physical disk is currently blocked by controller. 7: The physical disk is not operational. 8: The physical disk is not a RAID capable disk 9: The physical disk has been removed. 10:The physical disk media has been placed in read only mode.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskProductID | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 | DisplayString | RO | MTFDDAV240TDU | |||||||||||||||||
column · DisplayString · read-only · current The model number of the physical disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSerialNo | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 | DisplayString | RO | 22323A6F2DE6 | |||||||||||||||||
column · DisplayString · read-only · current The physical disk's unique identification number from the manufacturer. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskRevision | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.8 | DisplayString | RO | D3DJ004 | |||||||||||||||||
column · DisplayString · read-only · current The firmware version of the physical disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskCapacityInMB | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 | INTEGER (1..2147483647) | RO | 228936 | |||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current The size of the physical disk in megabytes. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskUsedSpaceInMB | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17 | INTEGER (1..2147483647) | RO | 228872 | |||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current The amount of used space in megabytes on the physical disk. This is not applicable for NVMe devices. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskFreeSpaceInMB | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19 | INTEGER (1..2147483647) | RO | 0 | |||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current The amount of free space in megabytes on the physical disk. This is not applicable for NVMe devices. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskBusType | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.21 | INTEGER | RO | sata(4) | |||||||||||||||||
column · INTEGER · read-only · current The bus type of the physical disk.
Possible values:
1: The bus type could not be determined.
2: Small Computer System Interface (SCSI).
3: Serial Attached SCSI (SAS).
4: Serial Advanced Technology Attachment (SATA).
5: Fibre channel.
6: PCIe.
7: NVMe.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSpareState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22 | INTEGER | RO | notASpare(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of the disk as a spare. Possible values: 1: Physical disk is not a spare. 2: Physical disk is a dedicated hot spare. 3: Physical disk is a global hot spare.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPartNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.27 | DisplayString | RO | MY-0T2GFX-MCP00-289-07R8-A00 | |||||||||||||||||
column · DisplayString · read-only · current The part number of the disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSASAddress | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.28 | DisplayString | RO | 0x0 | |||||||||||||||||
column · DisplayString · read-only · current The SAS address of the physical disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskNegotiatedSpeed | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.29 | INTEGER | RO | sixGbps(4) | |||||||||||||||||
column · INTEGER · read-only · current The data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps 6: 5 GT/s (applicable for NVMe devices). 7: 8 GT/s (applicable for NVMe devices). 8: 16 GT/s (applicable for NVMe devices). 9: 32 GT/s (applicable for NVMe devices).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskCapableSpeed | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.30 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The maximum data transfer speed supported by the disk in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps 6: 5 GT/s (applicable for NVMe devices). 7: 8 GT/s (applicable for NVMe devices). 8: 16 GT/s (applicable for NVMe devices). 9: 32 GT/s (applicable for NVMe devices).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSmartAlertIndication | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether the physical disk has received a predictive failure alert. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufactureDay | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32 | DisplayString | RO | 0 | |||||||||||||||||
column · DisplayString · read-only · current The day of the week (1=Sunday thru 7=Saturday) on which the physical disk was manufactured. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufactureWeek | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33 | DisplayString | RO | 0 | |||||||||||||||||
column · DisplayString · read-only · current The week (1 thru 53) in which the physical disk was manufactured. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufactureYear | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.34 | DisplayString | RO | 0 | |||||||||||||||||
column · DisplayString · read-only · current The four digit year in which the physical disk was manufactured. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskMediaType | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35 | INTEGER | RO | ssd(3) | |||||||||||||||||
column · INTEGER · read-only · current The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Device (SSD).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPowerState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.42 | INTEGER | RO | on(5) | |||||||||||||||||
column · INTEGER · read-only · current The power state of the physical disk. Possible Values: 1: Not one of the following. 2: The physical disk is in the spun up state. 3: The physical disk is in the spun down state. 4: The physical disk is changing from spun down state to spun up state or vice versa. 5: The Solid State Device (SSD) is powered on.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskRemainingRatedWriteEndurance | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.49 | INTEGER (0..255) | RO | 100 | |||||||||||||||||
column · INTEGER (0..255) · read-only · current This property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if the value is not available or not applicable (in the case of HDD media type) the value will be 255. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskOperationalState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.50 | INTEGER | RO | notApplicable(1) | |||||||||||||||||
column · INTEGER · read-only · current The state of the physical disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: Data from a redundant virtual disk is currently being rebuilt onto the physical disk. 3: Data on the disk is being erased. 4: Data is being copied from a hot spare disk to the physical disk or vice versa.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskProgress | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.51 | INTEGER (0..100) | RO | 0 | |||||||||||||||||
column · INTEGER (0..100) · read-only · current The progress percentage of the operation that is being performed on the physical disk. This is applicable only if there is a progressive operations ongoing Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSecurityStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52 | INTEGER | RO | notSupported(2) | |||||||||||||||||
column · INTEGER · read-only · current The security/encryption status of the physical disk. Possible Values: 1: The physical disk supports encryption. 2: The physical disk does not support encryption 3: The physical disk is encrypted. 4: The physical disk is locked by a key. 5: The physical disk is locked by a foreign key.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskFormFactor | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.53 | INTEGER | RO | unknown(1) | |||||||||||||||||
column · INTEGER · read-only · current The form factor of the physical disk.
Possible values:
1: The form factor could not be determined.
2: 1.8 inch.
3: 2.5 inch.
4: 3.5 inch.
5: EDSFFE1.L.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.54 | FQDDString | RO | Disk.Direct.0-0:AHCI.Integrated.1-1 | |||||||||||||||||
column · FQDDString · read-only · current The physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 | DisplayString | RO | Disk 0 on Integrated AHCI controller 1 | |||||||||||||||||
column · DisplayString · read-only · current The physical disk's friendly FQDD as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskT10PICapability | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.57 | INTEGER | RO | notCapable(3) | |||||||||||||||||
column · INTEGER · read-only · current Indicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Capable of supporting T10 PI. 3: Not capable of supporting T10 PI.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskBlockSizeInBytes | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.58 | INTEGER (1..2147483647) | RO | 512 | |||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current The block size (in bytes) of the physical disk. This is not applicable for NVMe devices. 1: 512. 2: 4096 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskProtocolVersion | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.59 | DisplayString | RO | Not Applicable | |||||||||||||||||
column · DisplayString · read-only · current Applicable for NVMe devices only. The NVMe protocol version supported by the device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPCIeNegotiatedLinkWidth | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.60 | INTEGER | RO | notApplicable(2) | |||||||||||||||||
column · INTEGER · read-only · current Applicable for NVMe devices only. The PCIe link width negotiated with the host during device initialization.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPCIeCapableLinkWidth | 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.61 | INTEGER | RO | notApplicable(2) | |||||||||||||||||
column · INTEGER · read-only · current Applicable for NVMe devices only. The PCIe link widths the device is capable of supporting.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TenclosureFanTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed fans in the external storage enclosure(s). The number of entries is related to number of fans discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureFanTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the fan table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CenclosureFanNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.1 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current Instance number of this fan. | |||||||||||||||||||||
| CenclosureFanName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The fan's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureFanState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current state of this fan. Possible states: 1: The current state could not be determined. 2: The fan is operating normally. 3: The fan has encountered a hardware problem or is not responding. 4: The fan is no longer connected to the enclosure or there exists a problem communicating to it. 5: The fan is unstable.
| |||||||||||||||||||||
| CenclosureFanSpeed | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.11 | INTEGER (1..2147483647) | RO | ||||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current Indicates the current relative speed of the fan. | |||||||||||||||||||||
| CenclosureFanComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.15 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureFanFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.20 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current The fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureFanDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.21 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The fan's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TenclosurePowerSupplyTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed Power Supply Units(PSU) in the external storage enclosure(s). The number of entries is related to number of power supply unit(s) discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosurePowerSupplyTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the power supply unit table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. | |||||||||||||||||||||
| CenclosurePowerSupplyNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current Instance number of this power supply unit. | |||||||||||||||||||||
| CenclosurePowerSupplyName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The power supply unit's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosurePowerSupplyState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current state of this power supply unit. Possible states: 1: The current state could not be determined. 2: The power supply unit is operating normally. 3: The power supply unit has encountered a hardware problem or is not responding. 4: The power supply unit is no longer connected to the enclosure or there exists a problem communicating to it. 5: The power supply unit is unstable.
| |||||||||||||||||||||
| CenclosurePowerSupplyPartNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The part number of the power supply unit. | |||||||||||||||||||||
| CenclosurePowerSupplyComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosurePowerSupplyFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current The power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosurePowerSupplyDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The power supply unit's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TenclosureTemperatureProbeTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed temperature probes in the external storage enclosure(s). The number of entries is related to number of temperature probes discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureTemperatureProbeTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the temperature probe table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. | |||||||||||||||||||||
| CenclosureTemperatureProbeNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.1 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current Instance number of this temperature probe. | |||||||||||||||||||||
| CenclosureTemperatureProbeName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The temperature probe's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureTemperatureProbeState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current state of this temperature probe. Possible states: 1: The current state could not be determined. 2: The temperature probe is operating normally. 3: The temperature probe has encountered a hardware problem or is not responding. 4: The temperature probe is no longer connected to the enclosure or there exists a problem communicating to it. 5: The temperature probe is unstable.
| |||||||||||||||||||||
| CenclosureTemperatureProbeMinWarningValue | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7 | INTEGER (-127..128) | RO | ||||||||||||||||||
column · INTEGER (-127..128) · read-only · current The minimum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeMinCriticalValue | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8 | INTEGER (-128..127) | RO | ||||||||||||||||||
column · INTEGER (-128..127) · read-only · current The minimum temperature that will force the probe into a error state. | |||||||||||||||||||||
| CenclosureTemperatureProbeMaxWarningValue | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.9 | INTEGER (-128..127) | RO | ||||||||||||||||||
column · INTEGER (-128..127) · read-only · current The maximum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeMaxCriticalValue | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.10 | INTEGER (-128..127) | RO | ||||||||||||||||||
column · INTEGER (-128..127) · read-only · current The maximum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeCurValue | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.11 | INTEGER (-128..127) | RO | ||||||||||||||||||
column · INTEGER (-128..127) · read-only · current The maximum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.13 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureTemperatureProbeFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.15 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current The temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureTemperatureProbeDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.16 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The temperature probe's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TenclosureManagementModuleTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed Enclosure Management Modules (EMM) in the external storage enclosure(s). The number of entries is related to number of enclosure management modules discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureManagementModuleTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the enclosure management module table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. | |||||||||||||||||||||
| CenclosureManagementModuleNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.1 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current Instance number of this enclosure management module. | |||||||||||||||||||||
| CenclosureManagementModuleName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The enclosure management module's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureManagementModuleState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current state of this enclosure management module. Possible states: 1: The current state could not be determined. 2: The enclosure management module is operating normally. 3: The enclosure management module has encountered a hardware problem or is not responding. 4: The enclosure management module is no longer connected to the enclosure or there exists a problem communicating to it. 5: The enclosure management module is unstable.
| |||||||||||||||||||||
| CenclosureManagementModulePartNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.6 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The part number of the enclosure management module. | |||||||||||||||||||||
| CenclosureManagementModuleFWVersion | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.8 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Firmware version of the enclosure management module. | |||||||||||||||||||||
| CenclosureManagementModuleComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.11 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureManagementModuleFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.15 | FQDDString | RO | ||||||||||||||||||
column · FQDDString · read-only · current The enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureManagementModuleDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The enclosure management module's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TbatteryTable | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed batteries. The number of entries is related to number of Batteries discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RbatteryTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the battery table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CbatteryNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 | INTEGER (1..255) | RO | ||||||||||||||||||
column · INTEGER (1..255) · read-only · current Instance number of this battery entry. | |||||||||||||||||||||
| CbatteryState | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold.
| |||||||||||||||||||||
| CbatteryComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.6 | ObjectStatusEnum | RO | ||||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | |||||||||||||||||||||
| CbatteryPredictedCapacity | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.10 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete This entry is obsolete. Use the batteryComponentStatus or batteryState instead.
| |||||||||||||||||||||
| CbatteryFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CbatteryDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The battery's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| NlogicalDevices | 1.3.6.1.4.1.674.10892.5.5.1.20.140 | ||||||||||||||||||||
| TvirtualDiskTable | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1 | NA | |||||||||||||||||||
table · not-accessible · current A table of managed virtual disks. The number of entries is related to number of virtual disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RvirtualDiskTableEntry | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry in the virtual disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CvirtualDiskNumber | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 | INTEGER (1..100000000) | RO | 1 | |||||||||||||||||
column · INTEGER (1..100000000) · read-only · current Instance number of this virtual disk entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskName | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 | DisplayString | RO | VD_R1_1 | |||||||||||||||||
column · DisplayString · read-only · current The virtual disk's label as entered by the user. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskState | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4 | INTEGER | RO | online(2) | |||||||||||||||||
column · INTEGER · read-only · current The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskSizeInMB | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6 | INTEGER (1..2147483647) | RO | 228872 | |||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current The size of the virtual disk in megabytes. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskWritePolicy | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10 | INTEGER | RO | writeThrough(1) | |||||||||||||||||
column · INTEGER · read-only · current The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskReadPolicy | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11 | INTEGER | RO | noReadAhead(1) | |||||||||||||||||
column · INTEGER · read-only · current The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskLayout | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13 | INTEGER | RO | r1(3) | |||||||||||||||||
column · INTEGER · read-only · current The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskStripeSize | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.14 | INTEGER | RO | sixtyFourKilobytes(10) | |||||||||||||||||
column · INTEGER · read-only · current The stripe size of this virtual disk. Possible values: 1: Not one of the following 2: Default. 3: 512 bytes 4: 1 kB, 5: 2 kB, 6: 4 kB, 7: 8 kB, 8: 16 kB, 9: 32 kB, 10: 64 kB, 11: 128 kB, 12: 256 kB, 13: 512 kB, 14: 1 MB, 15: 2 MB, 16: 4 MB, 17: 8 MB, 18: 16 MB
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskComponentStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 | ObjectStatusEnum | RO | 3 | |||||||||||||||||
column · ObjectStatusEnum · read-only · current The status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskBadBlocksDetected | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether the virtual disk has bad blocks. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskSecured | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.24 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether the virtual disk is secured or not. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskIsCacheCade | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.25 | BooleanType | RO | 0 | |||||||||||||||||
column · BooleanType · read-only · current Indicates whether the virtual disk is being used as a secondary cache by the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskDiskCachePolicy | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.26 | INTEGER | RO | defullt(3) | |||||||||||||||||
column · INTEGER · read-only · current The cache policy of the physical disks that are part of this virtual disk Possible values: 1: Enabled. 2: Disabled. 3: Default.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskOperationalState | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30 | INTEGER | RO | notApplicable(1) | |||||||||||||||||
column · INTEGER · read-only · current The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskProgress | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.31 | INTEGER (0..100) | RO | 0 | |||||||||||||||||
column · INTEGER (0..100) · read-only · current The progress percentage of the operation that is being performed on the virtual disk. This is applicable only if there is a progressive operations ongoing Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskAvailableProtocols | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.32 | DisplayString | RO | SATA | |||||||||||||||||
column · DisplayString · read-only · current List of protocols support by physical disks part of this virtual disk. For e.g. SAS for Serial Attached SCSI or SATA for Serial Advanced Technology Attachment. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskMediaType | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.33 | DisplayString | RO | SSD | |||||||||||||||||
column · DisplayString · read-only · current List of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskRemainingRedundancy | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.34 | INTEGER (0..2) | RO | 1 | |||||||||||||||||
column · INTEGER (0..2) · read-only · current The number of physical disks which can be lost before the virtual disk loses its redundancy. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskFQDD | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35 | FQDDString | RO | Disk.Virtual.0:AHCI.Integrated.1-1 | |||||||||||||||||
column · FQDDString · read-only · current The virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskDisplayName | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36 | DisplayString | RO | Disk.Virtual.0:AHCI.Integrated.1-1 | |||||||||||||||||
column · DisplayString · read-only · current The virtual disk's friendly FQDD as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskT10PIStatus | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.37 | INTEGER | RO | disabled(3) | |||||||||||||||||
column · INTEGER · read-only · current Indicates whether the virtual disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Enabled. 3: Disabled.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvirtualDiskBlockSizeInBytes | 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.38 | INTEGER (1..2147483647) | RO | 512 | |||||||||||||||||
column · INTEGER (1..2147483647) · read-only · current The block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1: 512. 2: 4096 Example values from LibreNMS test devices
| |||||||||||||||||||||
| NconformanceGroup | 1.3.6.1.4.1.674.10892.5.6 | ||||||||||||||||||||
| NconformanceMIBCompliances | 1.3.6.1.4.1.674.10892.5.6.1 | ||||||||||||||||||||
| NconformanceMIBGroups | 1.3.6.1.4.1.674.10892.5.6.2 | ||||||||||||||||||||
| GracInfoObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.1 | ||||||||||||||||||||
group · current A collection of objects providing information about the remote access card. | |||||||||||||||||||||
| GchassisInfoObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.2 | ||||||||||||||||||||
group · current A collection of objects providing information about the Chassis group. | |||||||||||||||||||||
| GsystemInfoObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.3 | ||||||||||||||||||||
group · current A collection of objects providing information about the System group.
| |||||||||||||||||||||
| GstatusInfoObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.4 | ||||||||||||||||||||
group · current A collection of objects providing information about the status group. | |||||||||||||||||||||
| GalertInfoObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.5 | ||||||||||||||||||||
group · current A collection of objects providing information about the alert group. | |||||||||||||||||||||
| GmibVersionInfoObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.6 | ||||||||||||||||||||
group · current A collection of objects providing information about the mib version group. | |||||||||||||||||||||
| GsystemStateTableInfoObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.7 | ||||||||||||||||||||
group · current A collection of objects providing information about the System State Table group.
| |||||||||||||||||||||
| GchassisInformationObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.8 | ||||||||||||||||||||
group · current A collection of objects providing information about the System chassis information group.
| |||||||||||||||||||||
| GchassisInformationTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.9 | ||||||||||||||||||||
group · current A collection of objects providing information about the System chassis information table group.
| |||||||||||||||||||||
| GeventLogTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.11 | ||||||||||||||||||||
group · current A collection of objects providing information about the event log table group. | |||||||||||||||||||||
| GsystemBiosTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.12 | ||||||||||||||||||||
group · current A collection of objects providing information about the system Bios table group. | |||||||||||||||||||||
| GfirmwareTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.13 | ||||||||||||||||||||
group · current A collection of objects providing information about the firmware table group. | |||||||||||||||||||||
| GintrusionTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.14 | ||||||||||||||||||||
group · current A collection of objects providing information about the intrusion table group. | |||||||||||||||||||||
| GlcLogTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.15 | ||||||||||||||||||||
group · current A collection of objects providing information about the lc log table group. | |||||||||||||||||||||
| GpowerUnitTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.16 | ||||||||||||||||||||
group · current A collection of objects providing information about the power unit table group. | |||||||||||||||||||||
| GpowerSupplyTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.17 | ||||||||||||||||||||
group · current A collection of objects providing information about the power supply table group.
| |||||||||||||||||||||
| GvoltageProbeTableTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.18 | ||||||||||||||||||||
group · current A collection of objects providing information about the Voltage Probe Table group.
| |||||||||||||||||||||
| GamperageProbeTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.19 | ||||||||||||||||||||
group · current A collection of objects providing information about the Amperage Probe Table group.
| |||||||||||||||||||||
| GsystemBatteryTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.20 | ||||||||||||||||||||
group · current A collection of objects providing information about the System Battery Table group. | |||||||||||||||||||||
| GpowerUsageTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.21 | ||||||||||||||||||||
group · current A collection of objects providing information about the Power Usage Table group.
| |||||||||||||||||||||
| GcoolingUnitTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.22 | ||||||||||||||||||||
group · current A collection of objects providing information about the Cooling Unit Table group. | |||||||||||||||||||||
| GcoolingDeviceTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.23 | ||||||||||||||||||||
group · current A collection of objects providing information about the Cooling Device Table group.
| |||||||||||||||||||||
| GtemperatureProbeTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.24 | ||||||||||||||||||||
group · current A collection of objects providing information about the Temperature Probe Table group.
| |||||||||||||||||||||
| GprocessorDeviceTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.25 | ||||||||||||||||||||
group · current A collection of objects providing information about the Processor Device Table group.
| |||||||||||||||||||||
| GprocessorDeviceStatusTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.26 | ||||||||||||||||||||
group · current A collection of objects providing information about the Processor Device Status Table group. | |||||||||||||||||||||
| GmemoryDeviceTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.27 | ||||||||||||||||||||
group · current A collection of objects providing information about the Memory Device Table group.
| |||||||||||||||||||||
| GpCIDeviceTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.28 | ||||||||||||||||||||
group · current A collection of objects providing information about the PCI Device Table group. | |||||||||||||||||||||
| GnetworkDeviceTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.29 | ||||||||||||||||||||
group · current A collection of objects providing information about the Network Device Table group.
| |||||||||||||||||||||
| GsystemSlotTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.30 | ||||||||||||||||||||
group · current A collection of objects providing information about the System Slot Table group. | |||||||||||||||||||||
| GfruTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.31 | ||||||||||||||||||||
group · current A collection of objects providing information about the Fru Table group. | |||||||||||||||||||||
| GbatteryTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.32 | ||||||||||||||||||||
group · current A collection of objects providing information about the Battery Table group. | |||||||||||||||||||||
| GcontrollerTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.33 | ||||||||||||||||||||
group · current A collection of objects providing information about the Controller Table group.
| |||||||||||||||||||||
| GphysicalDiskTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.34 | ||||||||||||||||||||
group · current A collection of objects providing information about the Physical Disk Table group.
| |||||||||||||||||||||
| GvirtualDiskTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.35 | ||||||||||||||||||||
group · current A collection of objects providing information about the Virtual Disk Table group.
| |||||||||||||||||||||
| GenclosureTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.36 | ||||||||||||||||||||
group · current A collection of objects providing information about the Enclosure Table group.
| |||||||||||||||||||||
| GenclosureManagementModuleTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.37 | ||||||||||||||||||||
group · current A collection of objects providing information about the Enclosure Management Module Table group. | |||||||||||||||||||||
| GenclosureFanTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.38 | ||||||||||||||||||||
group · current A collection of objects providing information about the Enclosure Fan Table group. | |||||||||||||||||||||
| GenclosurePowerSupplyTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.39 | ||||||||||||||||||||
group · current A collection of objects providing information about the Enclosure Power Supply Table group. | |||||||||||||||||||||
| GenclosureTemperatureProbeTableObjGroup | 1.3.6.1.4.1.674.10892.5.6.2.40 | ||||||||||||||||||||
group · current A collection of objects providing information about the Enclosure Temperature Probe Table group.
| |||||||||||||||||||||
| NconformanceMIBnotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4 | ||||||||||||||||||||
| Galertnotification | 1.3.6.1.4.1.674.10892.5.6.4.1 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertAutomaticSystemRecoveryTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.2 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GalertBatteryTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.3 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GcableTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.4 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GcmcTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.5 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GprocessorDeviceStatusTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.6 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GprocessorDeviceAbsentTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.7 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GfanTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.8 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GfiberChannelTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.9 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GhardwareConfigurationTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.10 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GioVirtualizationTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.11 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GlinkStatusTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.12 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GmemoryDeviceTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.13 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GnicTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.14 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GosTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.15 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GpciDeviceTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.16 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GphysicaldiskTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.17 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GbiosPOSTTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.18 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GpowerSupplyTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.19 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GpowerSupplyAbsentTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.20 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GpowerUsageTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.21 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GredundancyTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.22 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GintegratedDualSDModuleTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.23 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GintegratedDualSDModuleAbsentTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.24 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GintegratedDualSDModuleRedundancyTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.25 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GsecurityEventTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.26 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GsystemEventLogTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.27 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GsoftwareConfigurationTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.28 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GtemperatureProbeTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.29 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GtemperatureStatisticsTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.30 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GvFlashMediaDeviceTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.31 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GvFlashMediaDeviceAbsentTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.32 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GvoltageProbeTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.33 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GracTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.34 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GsystemPerformanceTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.35 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GbatteryTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.36 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GstorageControllerTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.37 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GenclosureTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.38 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GfanStorageTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.39 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GphysicalDiskTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.40 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GstoragePowerSupplyTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.41 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertStorageSecurityTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.42 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertStorageManagementTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.43 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertStorageTemperatureProbeTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.44 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertStorageVirtualDiskTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.45 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertUpdateJobTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.46 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GalertSoftwareChangeUpdateNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.47 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertCMCAuditNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.48 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertDebugNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.49 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertiDRACIPAddressChangeNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.50 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GalertLicenseNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.51 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertPCIDeviceAuditNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.52 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GalertPowerSupplyAuditNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.53 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertPowerUsageAuditNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.54 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertSystemPowerStateChangeNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.55 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertUserTrackingNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.56 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GalertAutoDiscoveryNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.57 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertNetworkConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.58 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertIPAddressConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.59 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertJobControlConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.60 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertPCIDeviceConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.61 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertSecurityConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.62 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertSWCConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.63 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertTestTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.64 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GalertInternaliDRACMemoryUnresponsiveTrapNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.65 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GstorageSolidstateDriveTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.66 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertConfigurationChangeAuditNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.67 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertServerIdleTimeNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.68 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement.
| |||||||||||||||||||||
| GalertHWCAuditNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.69 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GliquidCoolingTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.70 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertStorageSoftwareDefinedSubSystemTrapsNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.71 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertTemparatureProbeAuditNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.72 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertPRDeviceDetectionNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.74 | ||||||||||||||||||||
group · current The one notification which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertSystemConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.75 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertSDKConfigurationNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.76 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertSDKSystemNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.77 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertCertificateValidityNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.78 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
| GalertSDPMSystemNotificationGroup | 1.3.6.1.4.1.674.10892.5.6.4.79 | ||||||||||||||||||||
group · current The two notifications which an SNMPv2 entity is required to implement. | |||||||||||||||||||||
Textual conventions
AmperageDiscreteReadingEnumINTEGERamperageIsBad(2)amperageIsGood(1)Amperage Discrete Reading Enum.
AmperageProbeTypeEnumINTEGERamperageProbeTypeIs12Volt(7)amperageProbeTypeIs1Point5Volt(3)amperageProbeTypeIs2Point5Volt(14)amperageProbeTypeIs3Point3volt(4)amperageProbeTypeIs5Volt(5)amperageProbeTypeIsBattery(12)amperageProbeTypeIsCore(10)amperageProbeTypeIsDiscrete(16)amperageProbeTypeIsFLEA(11)amperageProbeTypeIsGTL(15)amperageProbeTypeIsIO(9)amperageProbeTypeIsMinus12Volt(8)amperageProbeTypeIsMinus5Volt(6)amperageProbeTypeIsOther(1)amperageProbeTypeIsPowerSupplyAmps(23)amperageProbeTypeIsPowerSupplyWatts(24)amperageProbeTypeIsSystemAmps(25)amperageProbeTypeIsSystemWatts(26)amperageProbeTypeIsTerminator(13)amperageProbeTypeIsUnknown(2)Amperage Probe Type Enum.
BladeGeometryEnumINTEGERdualWidthFullHeight(6)dualWidthHalfHeight(4)other(1)singleWidthFullHeight(5)singleWidthHalfHeight(3)singleWidthQuarterHeight(7)u1FullWidth(10)u1HalfWidth(8)u1QuarterWidth(9)unknown(2)Blade Geometry enum.
BooleanTypeINTEGER (0..1)Integer with a range of (0..1). Where 0 = FALSE, 1 = TRUE
ChassisIdentifyControlCapabilitiesFlagsINTEGERenableCapable(2)identifyCapable(8)notReadyCapable(4)unknownCapabilities(1)Chassis Identify Control Capabilities Flags.
ChassisIdentifyControlSettingsFlagsINTEGERenabled(2)identifyChassis(8)identifyChassisAndEnable(10)notReady(4)unknown(1)Chassis Identify Control Settings Flags.
ChassisSystemClassEnumINTEGERdesktopClass(5)netPCClass(7)other(1)portableClass(6)serverClass(4)storageClass(8)unknown(2)workstationClass(3)Chassis System Class Enum.
ChassisTypeEnumINTEGERallInOne(13)busExpansionChassis(20)desktop(3)dockingStation(12)expansionChassis(18)handHeld(11)lapTop(9)lowProfileDesktop(4)lunchBox(16)mainSystemChassis(17)miniTower(6)multiSystemChassis(25)noteBook(10)other(1)peripheralChassis(21)pizzaBox(5)portable(8)rackMountChassis(23)raidChassis(22)sealedCasePC(24)spaceSaving(15)subChassis(19)subNoteBook(14)tower(7)unknown(2)Chassis Type Enum.
CoolingDeviceDiscreteReadingEnumINTEGERcoolingDeviceIsBad(2)coolingDeviceIsGood(1)Cooling Device Discrete Reading Enum.
CoolingDeviceSubTypeEnumINTEGERcoolingDeviceSubTypeIsAFanReadsONorOFF(4)coolingDeviceSubTypeIsAFanThatReadsInRPM(3)coolingDeviceSubTypeIsAPowerSupplyFanThatReadsONorOFF(6)coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM(5)coolingDeviceSubTypeIsDiscrete(16)coolingDeviceSubTypeIsOther(1)coolingDeviceSubTypeIsUnknown(2)Cooling Device Sub Type Enum.
CoolingDeviceTypeEnumINTEGERcoolingDeviceTypeIsABlower(4)coolingDeviceTypeIsACabinetFan(6)coolingDeviceTypeIsAChipFan(5)coolingDeviceTypeIsAFan(3)coolingDeviceTypeIsAHeatPipe(8)coolingDeviceTypeIsAPowerSupplyFan(7)coolingDeviceTypeIsActiveCooling(10)coolingDeviceTypeIsOther(1)coolingDeviceTypeIsPassiveCooling(11)coolingDeviceTypeIsRefrigeration(9)coolingDeviceTypeIsUnknown(2)Cooling Device Type Enum.
DateNameOCTET STRING (SIZE (25))String type for date strings of a given DateName format.
FQDDStringOCTET STRING (SIZE (0..512))String type for FQDD strings.
FirmwareTypeINTEGERiDRAC7(21)iDRAC8(22)iDRAC9(23)lifecycleController(20)other(1)unknown(2)Firmware Type.
HostControlCapabilitiesFlagsINTEGERmanualAllExceptOperatingSystemShutdownCapable(7)manualFullyCapable(15)manualOperatingSystemShutdownCapable(8)manualPowerCycleCapable(4)manualPowerCycleWithOSShutdownCapable(256)manualPowerCycleWithoutOSShutdownCapable(512)manualPowerOFFCapable(2)manualPowerOffWithOSShutdownCapable(64)manualPowerOffWithoutOSShutdownCapable(128)manualRebootCapable(1)manualRebootWithOSShutdownCapable(16)manualRebootWithoutOSShutdownCapable(32)Host Control Capabilities Flags.
HostControlSettingsFlagsINTEGERmanualOperatingSystemShutdown(8)manualOperatingSystemShutdownThenPowerCycle(12)manualOperatingSystemShutdownThenPowerOFF(10)manualOperatingSystemShutdownThenReboot(9)manualPowerCycle(4)manualPowerOFF(2)manualReboot(1)Host Control Settings Flags.
IntrusionReadingEnumINTEGERchassisBreachSensorFailure(4)chassisBreached(2)chassisBreachedPrior(3)chassisNotBreached(1)Intrusion Reading Enum.
IntrusionTypeEnumINTEGERchassisBreachDetectionWhenPowerOFF(2)chassisBreachDetectionWhenPowerON(1)Intrusion Type Enum.
LEDControlCapabilitiesFlagsINTEGERalertOnErrorCapable(2)alertOnWarningAndErrorCapable(4)alertOnWarningOrErrorCapable(6)unknown(1)LED Control Capabilities Flags.
LEDControlSettingsFlagsINTEGERalertOnError(2)alertOnWarningAndError(4)unknown(1)LED Control Settings Flags.
LcLogCategoryEnumINTEGERaudit(4)configuration(5)storage(2)system(1)updates(3)workNotes(6)LC Log Category Enum.
LogFormatTypeINTEGERascii(2)raw(1)uniCode(3)Log Format Type.
MACAddressOCTET STRING (SIZE (6))String type for MAC Address strings.
MemoryDeviceTypeEnumINTEGERdeviceTypeIs3DRAM(14)deviceTypeIsCDRAM(13)deviceTypeIsDDR(18)deviceTypeIsDDR2(19)deviceTypeIsDDR2FBDIMM(20)deviceTypeIsDDR3(24)deviceTypeIsDDR4(26)deviceTypeIsDRAM(3)deviceTypeIsEDRAM(4)deviceTypeIsEEPROM(10)deviceTypeIsEPROM(12)deviceTypeIsFBD2(25)deviceTypeIsFEPROM(11)deviceTypeIsFLASH(9)deviceTypeIsOther(1)deviceTypeIsRAM(7)deviceTypeIsRDRAM(17)deviceTypeIsROM(8)deviceTypeIsSDRAM(15)deviceTypeIsSGRAM(16)deviceTypeIsSRAM(6)deviceTypeIsUnknown(2)deviceTypeIsVRAM(5)Memory Device Type Enum.
MemoryPropertyEnumINTEGERnotApplicable(255)Memory Property Enum.
MemoryTechnologyEnumINTEGERdram(3)intelpersistentmemory(7)nvdimmf(5)nvdimmn(4)nvdimmp(6)other(1)unknown(2)Memory Technology Enum.
NMIButtonControlCapabilitiesFlagsINTEGERenableCapable(2)unknownCapabilities(1)NMI Button Control Capabilities Flags.
NMIButtonControlSettingsFlagsINTEGERdisabled(4)enabled(2)unknown(1)NMI Button Control Settings Flags.
NetworkDeviceCapabilitiesFlagsINTEGERfcoeOffload(8)iscsiOffload(4)supported(1)toe(2)Network Device Capabilities Flags.
NetworkDeviceConnectionStatusEnumINTEGERconnected(1)disconnected(2)driverBad(3)driverDisabled(4)hardwareClosing(12)hardwareInitalizing(10)hardwareNotReady(13)hardwareResetting(11)Network Device Connection Status Enum.
NetworkDeviceTOECapabilityFlagsINTEGERavailable(2)cannotBeDetermined(8)driverNotResponding(16)notAvailable(4)unknown(1)Network Device TOE Capability Flags.
NetworkDeviceiSCSICapabilityFlagsINTEGERavailable(2)cannotBeDetermined(8)driverNotResponding(16)notAvailable(4)unknown(1)Network Device iSCSI Capability Flags.
ObjectRangeINTEGER (1..128)Integer with a range of (1..128).
ObjectStatusEnumINTEGERcritical(5)nonCritical(4)nonRecoverable(6)ok(3)other(1)unknown(2)Status of an object.
PowerButtonControlCapabilitiesFlagsINTEGERenableCapable(2)unknownCapabilities(1)Power Button Control Capabilities Flags.
PowerButtonControlSettingsFlagsINTEGERdisabled(4)enabled(2)unknown(1)Power Button Control Settings Flags.
PowerCapCapabilitiesFlagsINTEGERdisable(2)enable(1)Power Cap Capabilities Flags.
PowerCapSettingEnumINTEGERenabled(1)Power Cap Setting Enum.
PowerStateStatusEnumINTEGERoff(3)on(4)other(1)unknown(2)Power State Status enum.
PowerSupplyConfigurationErrorTypeEnumINTEGERprocessorMissing(3)revisionMismatch(2)vendorMismatch(1)Power Supply Configuration Error Type Enum.
PowerSupplySensorStateFlagsINTEGERacLostOrOutOfRange(16)acOutOfRangeButPresent(32)configurationError(64)predictiveFailure(4)presenceDetected(1)psACLost(8)psFailureDetected(2)Power Supply Sensor State Flags.
PowerSupplyStateCapabilitiesUniqueFlagsINTEGERnotReadyCapable(4)onlineCapable(2)unknown(1)Power Supply State Capabilities Unique Flags.
PowerSupplyStateSettingsUniqueFlagsINTEGERacPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline(242)acPowerIsON(128)acSwitchIsON(64)fanFailure(8)notReady(4)onLine(2)onlineAndAcPowerIsON(130)onlineAndFanFailure(10)onlineAndPredictiveFailure(210)onlineandAcSwitchIsON(66)powerSupplyIsOK(32)powerSupplyIsON(16)unknown(1)Power Supply State Settings Unique Flags.
PowerSupplyTypeEnumINTEGERpowerSupplyTypeIsAC(9)powerSupplyTypeIsBattery(5)powerSupplyTypeIsConverter(7)powerSupplyTypeIsDC(10)powerSupplyTypeIsLinear(3)powerSupplyTypeIsOther(1)powerSupplyTypeIsRegulator(8)powerSupplyTypeIsSwitching(4)powerSupplyTypeIsUPS(6)powerSupplyTypeIsUnknown(2)powerSupplyTypeIsVRM(11)Power Supply Type Enum.
ProbeCapabilitiesFlagsINTEGERlowerNonCriticalThresholdDefaultCapable(8)lowerNonCriticalThresholdSetCapable(2)upperNonCriticalThresholdDefaultCapable(4)upperNonCriticalThresholdSetCapable(1)Probe Capabilities flags.
ProcessorDeviceFamilyINTEGERdeviceFamilyIs68000(98)deviceFamilyIs68010(99)deviceFamilyIs68020(100)deviceFamilyIs68030(101)deviceFamilyIs68040(96)deviceFamilyIs68xxx(97)deviceFamilyIs80286(4)deviceFamilyIs80287(8)deviceFamilyIs80387(9)deviceFamilyIs80487(10)deviceFamilyIs8086(3)deviceFamilyIs8087(7)deviceFamilyIsAMD2900(30)deviceFamilyIsAMDAthlon(29)deviceFamilyIsAMDAthlon64(131)deviceFamilyIsAMDAthlon64X2DualCore(136)deviceFamilyIsAMDAthlonDualCore(234)deviceFamilyIsAMDAthlonII(237)deviceFamilyIsAMDAthlonIIDualMobileM(58)deviceFamilyIsAMDAthlonMP(183)deviceFamilyIsAMDAthlonX2DualCore(143)deviceFamilyIsAMDAthlonXP(182)deviceFamilyIsAMDDuron(184)deviceFamilyIsAMDOpteron(132)deviceFamilyIsAMDOpteron4100(60)deviceFamilyIsAMDOpteron4200(62)deviceFamilyIsAMDOpteron6100(59)deviceFamilyIsAMDOpteron6200(61)deviceFamilyIsAMDPhenomFXQuadCore(140)deviceFamilyIsAMDPhenomII(236)deviceFamilyIsAMDPhenomTripleCore(231)deviceFamilyIsAMDPhenomX2DualCore(142)deviceFamilyIsAMDPhenomX4QuadCore(141)deviceFamilyIsAMDSempron(133)deviceFamilyIsAMDSempronM(239)deviceFamilyIsAMDSempronSI(235)deviceFamilyIsAMDTurion64Mobile(134)deviceFamilyIsAMDTurion64X2Mobile(137)deviceFamilyIsAMDTurionDualCoreMobile(233)deviceFamilyIsAMDTurionIIDualMobileM(57)deviceFamilyIsAMDTurionIIUltraDualMobileM(56)deviceFamilyIsAMDTurionUltraDualCoreMobile(232)deviceFamilyIsAMDZen(107)deviceFamilyIsAS400(180)deviceFamilyIsAlpha(48)deviceFamilyIsAlpha21064(49)deviceFamilyIsAlpha21066(50)deviceFamilyIsAlpha21164(51)deviceFamilyIsAlpha21164PC(52)deviceFamilyIsAlpha21164a(53)deviceFamilyIsAlpha21264(54)deviceFamilyIsAlpha21364(55)deviceFamilyIsCeleron(15)deviceFamilyIsCrusoeTM3000(121)deviceFamilyIsCrusoeTM5000(120)deviceFamilyIsDualCoreAMDOpteron(135)deviceFamilyIsDualCoreIntelCeleron(199)deviceFamilyIsDualCoreIntelXeon3000(162)deviceFamilyIsDualCoreIntelXeon3xxx(215)deviceFamilyIsDualCoreIntelXeon5000(165)deviceFamilyIsDualCoreIntelXeon5100(164)deviceFamilyIsDualCoreIntelXeon5200(171)deviceFamilyIsDualCoreIntelXeon5xxx(218)deviceFamilyIsDualCoreIntelXeon7100(168)deviceFamilyIsDualCoreIntelXeon7200(172)deviceFamilyIsDualCoreIntelXeon7xxx(221)deviceFamilyIsDualCoreIntelXeonLV(166)deviceFamilyIsDualCoreIntelXeonULV(167)deviceFamilyIsESA390G6(203)deviceFamilyIsEfficeonTM8000(122)deviceFamilyIsEmbeddedAMDOpertonQuadCore(230)deviceFamilyIsG4(201)deviceFamilyIsG5(202)deviceFamilyIsHobbit(112)deviceFamilyIsIBM390(200)deviceFamilyIsIntel386(5)deviceFamilyIsIntel486(6)deviceFamilyIsIntelAtom(43)deviceFamilyIsIntelCeleronD(186)deviceFamilyIsIntelCeleronM(130)deviceFamilyIsIntelCore2(190)deviceFamilyIsIntelCore2Duo(191)deviceFamilyIsIntelCore2DuoMobile(196)deviceFamilyIsIntelCore2Extreme(193)deviceFamilyIsIntelCore2ExtremeMobile(195)deviceFamilyIsIntelCore2Quad(194)deviceFamilyIsIntelCore2Solo(192)deviceFamilyIsIntelCore2SoloMobile(197)deviceFamilyIsIntelCoreDuo(40)deviceFamilyIsIntelCoreDuoMobile(41)deviceFamilyIsIntelCoreSolo(189)deviceFamilyIsIntelCoreSoloMobile(42)deviceFamilyIsIntelCorei3(206)deviceFamilyIsIntelCorei5(205)deviceFamilyIsIntelCorei7(198)deviceFamilyIsIntelItanium2(24)deviceFamilyIsIntelPentium4HT(179)deviceFamilyIsIntelPentiumD(187)deviceFamilyIsIntelPentiumExtreme(188)deviceFamilyIsIntelPentiumM(185)deviceFamilyIsIntelXeon(21)deviceFamilyIsIntelXeonMP(23)deviceFamilyIsItanium(20)deviceFamilyIsK5(25)deviceFamilyIsK6(26)deviceFamilyIsK6Dash2(27)deviceFamilyIsK6Dash2Plus(31)deviceFamilyIsK6Dash3(28)deviceFamilyIsM1(176)deviceFamilyIsM2(177)deviceFamilyIsMIPS(64)deviceFamilyIsMIPSR10000(69)deviceFamilyIsMIPSR4000(65)deviceFamilyIsMIPSR4200(66)deviceFamilyIsMIPSR4400(67)deviceFamilyIsMIPSR4600(68)deviceFamilyIsMultiCoreIntelXeon(214)deviceFamilyIsMultiCoreIntelXeon3400(224)deviceFamilyIsMultiCoreIntelXeon7400(175)deviceFamilyIsMultiCoreIntelXeon7xxx(223)deviceFamilyIsOther(1)deviceFamilyIsPARISC(144)deviceFamilyIsPARISC7100(150)deviceFamilyIsPARISC7100LC(149)deviceFamilyIsPARISC7200(148)deviceFamilyIsPARISC7300LC(147)deviceFamilyIsPARISC8000(146)deviceFamilyIsPARISC8500(145)deviceFamilyIsPentium(11)deviceFamilyIsPentium4(22)deviceFamilyIsPentiumII(13)deviceFamilyIsPentiumIII(17)deviceFamilyIsPentiumIIISpeedStep(19)deviceFamilyIsPentiumIIIXeon(18)deviceFamilyIsPentiumIIXeon(16)deviceFamilyIsPentiumMMX(14)deviceFamilyIsPentiumPro(12)deviceFamilyIsPowerPC(32)deviceFamilyIsPowerPC601(33)deviceFamilyIsPowerPC603(34)deviceFamilyIsPowerPC603Plus(35)deviceFamilyIsPowerPC604(36)deviceFamilyIsPowerPC620(37)deviceFamilyIsPowerPC750(39)deviceFamilyIsPowerPCx704(38)deviceFamilyIsQuadCoreAMDOpteron(138)deviceFamilyIsQuadCoreIntelXeon(170)deviceFamilyIsQuadCoreIntelXeon3200(161)deviceFamilyIsQuadCoreIntelXeon3xxx(216)deviceFamilyIsQuadCoreIntelXeon5300(163)deviceFamilyIsQuadCoreIntelXeon5400(169)deviceFamilyIsQuadCoreIntelXeon5xxx(219)deviceFamilyIsQuadCoreIntelXeon7300(173)deviceFamilyIsQuadCoreIntelXeon7400(174)deviceFamilyIsQuadCoreIntelXeon7xxx(222)deviceFamilyIsSPARC(80)deviceFamilyIsSixCoreAMDOpteron(238)deviceFamilyIsSuperSPARC(81)deviceFamilyIsThirdGenerationAMDOpteron(139)deviceFamilyIsUltraSPARC(84)deviceFamilyIsUltraSPARCII(85)deviceFamilyIsUltraSPARCIII(87)deviceFamilyIsUltraSPARCIIIi(88)deviceFamilyIsUltraSPARCIIi(86)deviceFamilyIsUnknown(2)deviceFamilyIsV30(160)deviceFamilyIsVIAC7(212)deviceFamilyIsVIAC7D(211)deviceFamilyIsVIAC7M(210)deviceFamilyIsVIAEden(213)deviceFamilyIsVIANano(217)deviceFamilyIsWeitek(128)deviceFamilyIsi860(250)deviceFamilyIsi960(251)deviceFamilyIsmicroSPARCII(82)deviceFamilyIsmicroSPARCIIep(83)deviceFamilyIszArchitectur(204)Processor Device Family.
ProcessorDeviceStatusReadingFlagsINTEGERconfigurationError(32)internalError(1)processorDisabled(256)processorPresent(128)processorThrottled(1024)terminatorPresent(512)thermalTrip(2)Processor Device Status Reading Flags.
ProcessorDeviceStatusStateINTEGERbiosDisabled(5)enabled(3)idle(6)other(1)unknown(2)userDisabled(4)Processor Device Status State.
ProcessorDeviceTypeINTEGERdeviceTypeIsAVideoProcessor(6)deviceTypeIsCPU(3)deviceTypeIsDSP(5)deviceTypeIsMathProcessor(4)deviceTypeIsOther(1)deviceTypeIsUnknown(2)Processor Device Type.
RacTypeEnumINTEGERidrac7DCS(21)idrac7modular(17)idrac7monolithic(16)idrac8DCS(34)idrac8modular(33)idrac8monolithic(32)idrac915GDCS(66)idrac915GModular(65)idrac915GMonolithic(64)idrac9DCS(50)idrac9Modular(49)idrac9Monolithic(48)other(1)unknown(2)RAC Type enum.
Signed32BitRangeINTEGER (-2147483647..2147483647)Integer with a range of (-2147483647..2147483647).
StateCapabilitiesFlagsINTEGERenableAndNotReadyCapable(6)enableCapable(2)notReadyCapable(4)unknownCapabilities(1)State Capabilities flags.
StateCapabilitiesLogUniqueFlagsINTEGERnotReadyCapable(4)onlineCapable(2)resetCapable(8)unknown(1)State Capabilities Log Unique Flags.
StateSettingsFlagsINTEGERenabled(2)enabledAndNotReady(6)notReady(4)unknown(1)State Settings flags.
StateSettingsLogUniqueFlagsINTEGERnotReady(4)online(2)reset(8)unknown(1)State Settings Log Unique Flags.
StatusProbeEnumINTEGERcriticalLower(8)criticalUpper(5)failed(10)nonCriticalLower(7)nonCriticalUpper(4)nonRecoverableLower(9)nonRecoverableUpper(6)ok(3)other(1)unknown(2)Probe Status enum.
StatusRedundancyEnumINTEGERdegraded(4)full(3)lost(5)notRedundant(6)other(1)redundancyOffline(7)unknown(2)Redundancy Status enum.
String64OCTET STRING (SIZE (0..64))General string type for 64 byte strings.
StringTypeOCTET STRING (SIZE (0..1023))General string type.
SystemBatteryReadingFlagsINTEGERfailed(2)predictiveFailure(1)presenceDetected(4)System Battery Reading Flags.
SystemFormFactorEnumINTEGERdualWidthFullHeight(10)dualWidthHalfHeight(8)other(1)singleWidthFullHeight(9)singleWidthHalfHeight(7)singleWidthQuarterHeight(11)u1(3)u1FullWidth(15)u1HalfWidth(13)u1QuarterWidth(14)u2(4)u4(5)u5(12)u7(6)unknown(2)System Form Factor enum.
SystemLockdownModeEnumINTEGERenabled(1)unknown(2)State Capabilities flags.
SystemPropertiesFlagsINTEGERenergySmart(1)System Properties Flags.
SystemSlotCategoryEnumINTEGERsystemSlotCategoryIsBusConnector(3)systemSlotCategoryIsMotherboard(5)systemSlotCategoryIsOther(1)systemSlotCategoryIsPCMCIA(4)systemSlotCategoryIsUnknown(2)System Slot Category Enum.
SystemSlotStateCapabilitiesFlagsINTEGERcanSupportAllHotPlugCapabilities(126)canSupportAllSlotAndAllHotPlugCapabilities(32766)canSupportAllSlotCapabilities(32640)systemSlotCanProvide3Point3Volts(256)systemSlotCanProvide5Volts(128)systemSlotCanSignalIfShared(512)systemSlotCanSupportCard16(1024)systemSlotCanSupportCardBus(2048)systemSlotCanSupportModemRingResume(8192)systemSlotCanSupportPMESignal(16384)systemSlotCanSupportZoomVideo(4096)systemSlotHotPlugCanBePoweredOn(4)systemSlotHotPlugCanSignalAdapterPresent(32)systemSlotHotPlugCanSignalAttention(8)systemSlotHotPlugCanSignalPowerButtonPressed(64)systemSlotHotPlugCanSignalPowerFault(16)systemSlotHotPlugIsHotPluggableCapable(2)systemSlotHotPlugIsUnknown(1)System Slot State Capabilities Flags.
SystemSlotStateSettingsFlagsINTEGERsupportsPMEand3P3VIsSharedand5VhasAdapterOnandHotPlugable(17316)supportsPMEand3P3Vand5VandHotPluggable(16770)supportsPMEand3P3Vand5VhasAdapterOn(16804)supportsPMEand3P3Vand5VhasAdapterOnandisHotPluggable(16806)systemSlotHotPlugAdapterIsPresent(32)systemSlotHotPlugAdapterPresentAndPoweredOn(36)systemSlotHotPlugHasPowerFaulted(16)systemSlotHotPlugIsAtAttention(8)systemSlotHotPlugIsHotPluggable(2)systemSlotHotPlugIsPoweredOn(4)systemSlotHotPlugIsUnknown(1)systemSlotHotPlugPowerButtonPressed(64)systemSlotIsShared(512)systemSlotProvides3Point3Volts(256)systemSlotProvides5Volts(128)systemSlotSupportsCard16(1024)systemSlotSupportsCardBus(2048)systemSlotSupportsModemRingResume(8192)systemSlotSupportsPMESignal(16384)systemSlotSupportsZoomVideo(4096)System Slot State Settings Flags.
SystemSlotTypeEnumINTEGERsystemSlotIsAGP(15)systemSlotIsAGP2X(16)systemSlotIsAGP4X(17)systemSlotIsAGP8X(25)systemSlotIsEISA(5)systemSlotIsIORiserCard(12)systemSlotIsISA(3)systemSlotIsMCA(4)systemSlotIsNuBUS(13)systemSlotIsOther(1)systemSlotIsPC98C20(18)systemSlotIsPC98C24(19)systemSlotIsPC98Card(22)systemSlotIsPC98E(20)systemSlotIsPC98LocalBus(21)systemSlotIsPCI(6)systemSlotIsPCI66MHz(14)systemSlotIsPCIExpress(24)systemSlotIsPCIExpressGen2(171)systemSlotIsPCIExpressGen2X1(172)systemSlotIsPCIExpressGen2X16(176)systemSlotIsPCIExpressGen2X2(173)systemSlotIsPCIExpressGen2X4(174)systemSlotIsPCIExpressGen2X8(175)systemSlotIsPCIExpressX1(166)systemSlotIsPCIExpressX16(170)systemSlotIsPCIExpressX2(167)systemSlotIsPCIExpressX4(168)systemSlotIsPCIExpressX8(169)systemSlotIsPCIX(23)systemSlotIsPCMCIA(7)systemSlotIsProcessorCard(10)systemSlotIsProprietary(9)systemSlotIsProprietaryMemory(11)systemSlotIsUnknown(2)systemSlotIsVLVESA(8)System Slot Type Enum.
SystemSlotUsageEnumINTEGERsystemSlotUsageIsAvailable(3)systemSlotUsageIsInUse(4)systemSlotUsageIsOther(1)systemSlotUsageIsUnknown(2)System Slot Usage Enum.
TemperatureDiscreteReadingEnumINTEGERtemperatureIsBad(2)temperatureIsGood(1)Temperature Discrete Reading Enum.
TemperatureProbeTypeEnumINTEGERtemperatureProbeTypeIsAmbientESM(3)temperatureProbeTypeIsDiscrete(16)temperatureProbeTypeIsOther(1)temperatureProbeTypeIsUnknown(2)Temperature Probe Type Enum.
Unsigned16BitRangeINTEGER (0..65535)Integer with a range of (0..65535).
Unsigned32BitRangeINTEGER (0..2147483647)Integer with a range of (0..2147483647).
Unsigned8BitRangeINTEGER (0..255)Integer with a range of (0..255).
VoltageDiscreteReadingEnumINTEGERvoltageIsBad(2)voltageIsGood(1)Voltage Discrete Reading Enum.
VoltageTypeEnumINTEGERvoltageProbeTypeIs12Volt(7)voltageProbeTypeIs1Point5Volt(3)voltageProbeTypeIs2Point5Volt(14)voltageProbeTypeIs3Point3Volt(4)voltageProbeTypeIs5Volt(5)voltageProbeTypeIsBattery(12)voltageProbeTypeIsCore(10)voltageProbeTypeIsDiscrete(16)voltageProbeTypeIsFLEA(11)voltageProbeTypeIsGTL(15)voltageProbeTypeIsGenericDiscrete(17)voltageProbeTypeIsIO(9)voltageProbeTypeIsMemoryStatus(19)voltageProbeTypeIsMinus12Volt(8)voltageProbeTypeIsMinus5Volt(6)voltageProbeTypeIsOther(1)voltageProbeTypeIsPSVoltage(18)voltageProbeTypeIsTerminator(13)voltageProbeTypeIsUnknown(2)Voltage Type Enum.
WatchControlSettingsFlagsINTEGERautomaticNotificationEnabled(4)automaticPowerCycleEnabled(2)automaticPowerOffEnabled(8)automaticRebootEnabled(1)WatchDog Control Settings Flags.
WatchDogControlCapabilitiesFlagsINTEGERautomaticAllExceptNotificationCapable(27)automaticFullyCapable(31)automaticNotificationCapable(4)automaticPowerCycleCapable(2)automaticPowerOffCapable(16)automaticRebootCapable(1)automaticWatchDogTimerCapable(8)WatchDog Control Capabilities Flags.
WatchDogTimerCapabilitiesFlagsINTEGERtype1Capable(1)type2Capable(2)type3Capable(4)WatchDog Timer Capabilities Flags.
Traps / Notifications
- alertAmperageProbeFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2177 - alertAmperageProbeNormal
1.3.6.1.4.1.674.10892.5.3.2.1.0.2179 - alertAmperageProbeWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2178 - alertAutoDiscoveryInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.10635 - alertAutomaticSystemRecovery
1.3.6.1.4.1.674.10892.5.3.2.1.0.2233 - alertBatteryFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2225 - alertBatteryNormal
1.3.6.1.4.1.674.10892.5.3.2.1.0.2227 - alertBatteryWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2226 - alertBiosPostFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2425 - alertCMCAuditFailure
1.3.6.1.4.1.674.10892.5.3.2.4.0.8689 - alertCMCAuditInformation
1.3.6.1.4.1.674.10892.5.3.2.4.0.8691 - alertCMCAuditWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8690 - alertCMCFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2545 - alertCMCWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2546 - alertCableFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2393 - alertCertificateValidityError
1.3.6.1.4.1.674.10892.5.3.2.1.0.9441 - alertCertificateValidityWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.9442 - alertDebugInformation
1.3.6.1.4.1.674.10892.5.3.2.4.0.8595 - alertDebugWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8594 - alertFanFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2153 - alertFanInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2155 - alertFanWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2154 - alertFiberChannelFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2537 - alertFiberChannelInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2539 - alertFiberChannelWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2538 - alertHWCAuditInformation
1.3.6.1.4.1.674.10892.5.3.2.4.0.8475 - alertHWCAuditWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8474 - alertHardwareConfigurationFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2329 - alertHardwareConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2331 - alertHardwareConfigurationWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2330 - alertIOVirtualizationFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2553 - alertIPAddressConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.10547 - alertIntegratedDualSDModuleAbsent
1.3.6.1.4.1.674.10892.5.3.2.1.0.2481 - alertIntegratedDualSDModuleFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2209 - alertIntegratedDualSDModuleInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2211 - alertIntegratedDualSDModuleRedundancyDegraded
1.3.6.1.4.1.674.10892.5.3.2.1.0.2490 - alertIntegratedDualSDModuleRedundancyInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2491 - alertIntegratedDualSDModuleRedundancyLost
1.3.6.1.4.1.674.10892.5.3.2.1.0.2489 - alertIntegratedDualSDModuleWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2210 - alertInternaliDRACMemoryUnresponsive
1.3.6.1.4.1.674.10892.5.3.2.1.0.2433 - alertJobControlConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.10267 - alertLicenseFailure
1.3.6.1.4.1.674.10892.5.3.2.4.0.8513 - alertLicenseInformation
1.3.6.1.4.1.674.10892.5.3.2.4.0.8515 - alertLicenseWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8514 - alertLinkStatusFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2249 - alertLinkStatusInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2251 - alertLinkStatusWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2250 - alertLiquidCoolingLeakFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.3049 - alertLiquidCoolingLeakInformational
1.3.6.1.4.1.674.10892.5.3.2.1.0.3051 - alertLiquidCoolingLeakWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.3050 - alertMemoryDeviceFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2265 - alertMemoryDeviceInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2267 - alertMemoryDeviceWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2266 - alertNetworkConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.10771 - alertNetworkConfigurationWarning
1.3.6.1.4.1.674.10892.5.3.2.5.0.10770 - alertNetworkFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2089 - alertNetworkInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2091 - alertNetworkWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2090 - alertOSFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2409 - alertOSInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2411 - alertPCIDeviceAuditWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8562 - alertPCIDeviceConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.10611 - alertPCIDeviceFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2417 - alertPCIDeviceInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2419 - alertPCIDeviceWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2418 - alertPRDeviceDetectionWarning
1.3.6.1.4.1.674.10892.5.3.2.5.0.10298 - alertPhysicalDiskFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2297 - alertPhysicalDiskInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2299 - alertPhysicalDiskWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2298 - alertPowerSupplyAbsent
1.3.6.1.4.1.674.10892.5.3.2.1.0.2465 - alertPowerSupplyAuditFailure
1.3.6.1.4.1.674.10892.5.3.2.4.0.8329 - alertPowerSupplyAuditWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8330 - alertPowerSupplyFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2185 - alertPowerSupplyNormal
1.3.6.1.4.1.674.10892.5.3.2.1.0.2187 - alertPowerSupplyWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2186 - alertPowerUsageAuditFailure
1.3.6.1.4.1.674.10892.5.3.2.4.0.8417 - alertPowerUsageAuditInformation
1.3.6.1.4.1.674.10892.5.3.2.4.0.8419 - alertPowerUsageAuditWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8418 - alertPowerUsageFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2273 - alertPowerUsageInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2275 - alertPowerUsageWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2274 - alertProcessorDeviceAbsent
1.3.6.1.4.1.674.10892.5.3.2.1.0.2457 - alertProcessorDeviceStatusFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2241 - alertProcessorDeviceStatusNormal
1.3.6.1.4.1.674.10892.5.3.2.1.0.2243 - alertProcessorDeviceStatusWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2242 - alertRACInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2531 - alertRacConfigurationChangeInformation
1.3.6.1.4.1.674.10892.5.3.2.4.0.8675 - alertRacConfigurationChangeWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8674 - alertRedundancyDegraded
1.3.6.1.4.1.674.10892.5.3.2.1.0.2474 - alertRedundancyInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2475 - alertRedundancyLost
1.3.6.1.4.1.674.10892.5.3.2.1.0.2473 - alertSDKConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.11275 - alertSDKConfigurationWarning
1.3.6.1.4.1.674.10892.5.3.2.5.0.11274 - alertSDKSystemInformational
1.3.6.1.4.1.674.10892.5.3.2.1.0.3083 - alertSDKSystemWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.3082 - alertSDPMSystemCritical
1.3.6.1.4.1.674.10892.5.3.2.1.0.3289 - alertSDPMSystemInformational
1.3.6.1.4.1.674.10892.5.3.2.1.0.3291 - alertSDPMSystemWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.3290 - alertSWCConfigurationFailure
1.3.6.1.4.1.674.10892.5.3.2.5.0.10529 - alertSWCConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.10531 - alertSWCConfigurationWarning
1.3.6.1.4.1.674.10892.5.3.2.5.0.10530 - alertSecurityConfigurationWarning
1.3.6.1.4.1.674.10892.5.3.2.5.0.10578 - alertSecurityFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2385 - alertSecurityInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2387 - alertSecurityWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2386 - alertServerIdleTime
1.3.6.1.4.1.674.10892.5.3.2.1.0.2435 - alertSoftwareChangeUpdateWarning
1.3.6.1.4.1.674.10892.5.3.2.3.0.6314 - alertSoftwareConfigurationFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2337 - alertSoftwareConfigurationInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2339 - alertSoftwareConfigurationWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2338 - alertStorageBatteryFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4273 - alertStorageBatteryInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4275 - alertStorageBatteryWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4274 - alertStorageControllerFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4329 - alertStorageControllerInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4331 - alertStorageControllerWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4330 - alertStorageEnclosureFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4337 - alertStorageEnclosureInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4339 - alertStorageEnclosureWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4338 - alertStorageFanFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4201 - alertStorageFanInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4203 - alertStorageFanWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4202 - alertStorageManagementFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4177 - alertStorageManagementInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4179 - alertStorageManagementWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4178 - alertStoragePhysicalDiskFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4345 - alertStoragePhysicalDiskInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4347 - alertStoragePhysicalDiskWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4346 - alertStoragePowerSupplyFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4233 - alertStoragePowerSupplyInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4235 - alertStoragePowerSupplyWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4234 - alertStorageSecurityFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4433 - alertStorageSecurityInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4435 - alertStorageSecurityWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4434 - alertStorageSoftwareDefinedSubSystemFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4761 - alertStorageSoftwareDefinedSubSystemWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4762 - alertStorageSolidstateDrive
1.3.6.1.4.1.674.10892.5.3.2.2.0.4370 - alertStorageTemperatureProbeFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4209 - alertStorageTemperatureProbeInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4211 - alertStorageTemperatureProbeWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4210 - alertStorageVirtualDiskFailure
1.3.6.1.4.1.674.10892.5.3.2.2.0.4353 - alertStorageVirtualDiskInformation
1.3.6.1.4.1.674.10892.5.3.2.2.0.4355 - alertStorageVirtualDiskWarning
1.3.6.1.4.1.674.10892.5.3.2.2.0.4354 - alertSystemConfigurationChangeInformation
1.3.6.1.4.1.674.10892.5.3.2.5.0.10627 - alertSystemEventLogFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2377 - alertSystemEventLogInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2379 - alertSystemEventLogWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2378 - alertSystemPerformanceWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2650 - alertSystemPowerStateChangeInformation
1.3.6.1.4.1.674.10892.5.3.2.4.0.8579 - alertTemperatureProbeChangeFailure
1.3.6.1.4.1.674.10892.5.3.2.4.0.8305 - alertTemperatureProbeFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2161 - alertTemperatureProbeNormal
1.3.6.1.4.1.674.10892.5.3.2.1.0.2163 - alertTemperatureProbeReadWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8306 - alertTemperatureProbeWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2162 - alertTemperatureStatisticsFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2521 - alertTemperatureStatisticsWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2522 - alertTestTrapEvent
1.3.6.1.4.1.674.10892.5.3.2.5.0.10395 - alertUpdateJobInformation
1.3.6.1.4.1.674.10892.5.3.2.3.0.6211 - alertUserTrackingWarning
1.3.6.1.4.1.674.10892.5.3.2.4.0.8490 - alertVoltageProbeFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2169 - alertVoltageProbeNormal
1.3.6.1.4.1.674.10892.5.3.2.1.0.2171 - alertVoltageProbeWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2170 - alertiDRACIPAddressChange
1.3.6.1.4.1.674.10892.5.3.2.4.0.8499 - alertvFlashMediaDeviceAbsent
1.3.6.1.4.1.674.10892.5.3.2.1.0.2515 - alertvFlashMediaDeviceFailure
1.3.6.1.4.1.674.10892.5.3.2.1.0.2505 - alertvFlashMediaDeviceInformation
1.3.6.1.4.1.674.10892.5.3.2.1.0.2507 - alertvFlashMediaDeviceWarning
1.3.6.1.4.1.674.10892.5.3.2.1.0.2506
Groups and compliance
- alertAutoDiscoveryNotificationGroup
- alertAutomaticSystemRecoveryTrapNotificationGroup
- alertBatteryTrapsNotificationGroup
- alertCMCAuditNotificationGroup
- alertCertificateValidityNotificationGroup
- alertConfigurationChangeAuditNotificationGroup
- alertDebugNotificationGroup
- alertHWCAuditNotificationGroup
- alertIPAddressConfigurationNotificationGroup
- alertInfoObjGroup
- alertInternaliDRACMemoryUnresponsiveTrapNotificationGroup
- alertJobControlConfigurationNotificationGroup
- alertLicenseNotificationGroup
- alertNetworkConfigurationNotificationGroup
- alertPCIDeviceAuditNotificationGroup
- alertPCIDeviceConfigurationNotificationGroup
- alertPRDeviceDetectionNotificationGroup
- alertPowerSupplyAuditNotificationGroup
- alertPowerUsageAuditNotificationGroup
- alertSDKConfigurationNotificationGroup
- alertSDKSystemNotificationGroup
- alertSDPMSystemNotificationGroup
- alertSWCConfigurationNotificationGroup
- alertSecurityConfigurationNotificationGroup
- alertServerIdleTimeNotificationGroup
- alertSoftwareChangeUpdateNotificationGroup
- alertStorageManagementTrapsNotificationGroup
- alertStorageSecurityTrapsNotificationGroup
- alertStorageSoftwareDefinedSubSystemTrapsNotificationGroup
- alertStorageTemperatureProbeTrapsNotificationGroup
- alertStorageVirtualDiskTrapsNotificationGroup
- alertSystemConfigurationNotificationGroup
- alertSystemPowerStateChangeNotificationGroup
- alertTemparatureProbeAuditNotificationGroup
- alertTestTrapNotificationGroup
- alertUpdateJobTrapNotificationGroup
- alertUserTrackingNotificationGroup
- alertiDRACIPAddressChangeNotificationGroup
- alertnotification
- amperageProbeTableObjGroup
- batteryTableObjGroup
- batteryTrapsNotificationGroup
- biosPOSTTrapNotificationGroup
- cableTrapsNotificationGroup
- chassisInfoObjGroup
- chassisInformationObjGroup
- chassisInformationTableObjGroup
- cmcTrapsNotificationGroup
- controllerTableObjGroup
- coolingDeviceTableObjGroup
- coolingUnitTableObjGroup
- enclosureFanTableObjGroup
- enclosureManagementModuleTableObjGroup
- enclosurePowerSupplyTableObjGroup
- enclosureTableObjGroup
- enclosureTemperatureProbeTableObjGroup
- enclosureTrapsNotificationGroup
- eventLogTableObjGroup
- fanStorageTrapsNotificationGroup
- fanTrapsNotificationGroup
- fiberChannelTrapsNotificationGroup
- firmwareTableObjGroup
- fruTableObjGroup
- hardwareConfigurationTrapsNotificationGroup
- integratedDualSDModuleAbsentTrapNotificationGroup
- integratedDualSDModuleRedundancyTrapsNotificationGroup
- integratedDualSDModuleTrapsNotificationGroup
- intrusionTableObjGroup
- ioVirtualizationTrapsNotificationGroup
- lcLogTableObjGroup
- linkStatusTrapsNotificationGroup
- liquidCoolingTrapsNotificationGroup
- memoryDeviceTableObjGroup
- memoryDeviceTrapsNotificationGroup
- mibVersionInfoObjGroup
- networkDeviceTableObjGroup
- nicTrapsNotificationGroup
- osTrapsNotificationGroup
- pCIDeviceTableObjGroup
- pciDeviceTrapsNotificationGroup
- physicalDiskTableObjGroup
- physicalDiskTrapsNotificationGroup
- physicaldiskTrapsNotificationGroup
- powerSupplyAbsentTrapNotificationGroup
- powerSupplyTableObjGroup
- powerSupplyTrapsNotificationGroup
- powerUnitTableObjGroup
- powerUsageTableObjGroup
- powerUsageTrapsNotificationGroup
- processorDeviceAbsentTrapNotificationGroup
- processorDeviceStatusTableObjGroup
- processorDeviceStatusTrapsNotificationGroup
- processorDeviceTableObjGroup
- racInfoObjGroup
- racTrapsNotificationGroup
- redundancyTrapsNotificationGroup
- securityEventTrapsNotificationGroup
- softwareConfigurationTrapsNotificationGroup
- statusInfoObjGroup
- storageControllerTrapsNotificationGroup
- storagePowerSupplyTrapsNotificationGroup
- storageSolidstateDriveTrapsNotificationGroup
- systemBatteryTableObjGroup
- systemBiosTableObjGroup
- systemEventLogTrapsNotificationGroup
- systemInfoObjGroup
- systemPerformanceTrapsNotificationGroup
- systemSlotTableObjGroup
- systemStateTableInfoObjGroup
- temperatureProbeTableObjGroup
- temperatureProbeTrapsNotificationGroup
- temperatureStatisticsTrapsNotificationGroup
- vFlashMediaDeviceAbsentTrapNotificationGroup
- vFlashMediaDeviceTrapsNotificationGroup
- virtualDiskTableObjGroup
- voltageProbeTableTableObjGroup
- voltageProbeTrapsNotificationGroup