DELLEMC-OS10-CHASSIS-MIB
Dell Inc.Dell EMC Networking OS10 Chassis MIB.
snmptranslate -m DELLEMC-OS10-CHASSIS-MIB -Tpsnmpwalk -v2c -c <community> -m DELLEMC-OS10-CHASSIS-MIB <host> 1.3.6.1.4.1.674.11000.5000.100.4Imports
| DELLEMC-OS10-SMI-MIB | os10 |
|---|---|
| DELLEMC-OS10-TC-MIB | Os10CardOperStatus, Os10ChassisDefType, Os10CmnOperStatus, Os10DeviceType, Os10SystemCardType |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ios10ChassisMib | 1.3.6.1.4.1.674.11000.5000.100.4 | ||||||||||||||||||||
identity Dell EMC Networking OS10 Chassis MIB. | |||||||||||||||||||||
| Nos10SysObject | 1.3.6.1.4.1.674.11000.5000.100.4.1 | ||||||||||||||||||||
| Nos10ChassisObject | 1.3.6.1.4.1.674.11000.5000.100.4.1.1 | ||||||||||||||||||||
| Sos10NumChassis | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.1 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current The total number of chassis configured on the cluster. | |||||||||||||||||||||
| Sos10MaxNumChassis | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.2 | Unsigned32 | RO | ||||||||||||||||||
scalar · Unsigned32 · read-only · current Indicates the maximum allowed chassis configurable on the cluster. | |||||||||||||||||||||
| Tos10ChassisTable | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3 | NA | |||||||||||||||||||
table · not-accessible · current A list of chassis in a cluster. The chassis table contains the information of each chassis in the cluster. | |||||||||||||||||||||
| Ros10ChassisEntry | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of chassis entries containing information for the chassis.
| |||||||||||||||||||||
| Cos10ChassisIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.1 | Unsigned32 | NA | ||||||||||||||||||
column · Unsigned32 · not-accessible · current A unique index for each chassis within the cluster. This value is the chassisId assigned to the chassis. | |||||||||||||||||||||
| Cos10ChassisType | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2 | Os10ChassisDefType | RO | 7 | |||||||||||||||||
column · Os10ChassisDefType · read-only · current The Dell EMC Networking Model number of the chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisMacAddr | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.3 | MacAddress | RO | 68:4f:64:01:50:ec | |||||||||||||||||
column · MacAddress · read-only · current A 6-octet MAC Address assigned to this chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisPartNum | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.4 | DisplayString (SIZE (0..11)) | RO | 02NK09 | |||||||||||||||||
column · DisplayString (SIZE (0..11)) · read-only · current The chassis manufacturer's part number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisPPID | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.5 | DisplayString (SIZE (0..24)) | RO | CN02NK09282988AT0259 | |||||||||||||||||
column · DisplayString (SIZE (0..24)) · read-only · current The chassis manufacturer's PPID. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisHwRev | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.6 | DisplayString (SIZE (0..10)) | RO | A03 | |||||||||||||||||
column · DisplayString (SIZE (0..10)) · read-only · current The chassis hardware revision number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisServiceTag | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.7 | DisplayString (SIZE (0..7)) | RO | CWTQXC2 | |||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The chassis's service tag. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisExpServiceCode | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.8 | DisplayString (SIZE (0..14)) | RO | 281 062 707 86 | |||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The chassis's express service code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisNumFanTrays | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.9 | Unsigned32 | RO | 4 | |||||||||||||||||
column · Unsigned32 · read-only · current Number of fan trays in the chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisNumPowerSupplies | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.10 | Unsigned32 | RO | 2 | |||||||||||||||||
column · Unsigned32 · read-only · current Number of power supplies in the chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisTemp | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11 | Integer32 | RO | 37 | |||||||||||||||||
column · Integer32 · read-only · current Temperature of the chassis.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisProductBase | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.12 | DisplayString (SIZE (0..16)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-only · current The solution id product base Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisProductSN | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.13 | DisplayString (SIZE (0..16)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-only · current The solution id product serial number Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10ChassisProductPN | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.14 | DisplayString (SIZE (0..16)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..16)) · read-only · current The solution id product part number Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tos10CardTable | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4 | NA | |||||||||||||||||||
table · not-accessible · current A list of line cards resident in the chassis. This table contains the information on each RPM and linecards in the chassis. | |||||||||||||||||||||
| Ros10CardEntry | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1 | NA | |||||||||||||||||||
row · not-accessible · current Entry for each card in the chassis. | |||||||||||||||||||||
| Cos10CardIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.1 | Unsigned32 | NA | ||||||||||||||||||
column · Unsigned32 · not-accessible · current A unique index for each card in the chassis. | |||||||||||||||||||||
| Cos10CardType | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.2 | Os10SystemCardType | RO | 7 | |||||||||||||||||
column · Os10SystemCardType · read-only · current Card's type. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardDescription | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.3 | DisplayString (SIZE (0..120)) | RO | S4128F-ON 28x10GbE, 2x100GbE QSFP28 Interface M… | |||||||||||||||||
column · DisplayString (SIZE (0..120)) · read-only · current A short description of the card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardStatus | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4 | Os10CardOperStatus | RO | 1 | |||||||||||||||||
column · Os10CardOperStatus · read-only · current The current operational state of the card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardTemp | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5 | Integer32 | RO | 37 | |||||||||||||||||
column · Integer32 · read-only · current Temperature of the card.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardPartNum | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.6 | DisplayString (SIZE (0..11)) | RO | 02NK09 | |||||||||||||||||
column · DisplayString (SIZE (0..11)) · read-only · current The card's part number Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardPPID | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.7 | DisplayString (SIZE (0..24)) | RO | CN02NK09282988AT0259 | |||||||||||||||||
column · DisplayString (SIZE (0..24)) · read-only · current The card's PPID. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardHwRev | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.8 | DisplayString (SIZE (0..10)) | RO | A03 | |||||||||||||||||
column · DisplayString (SIZE (0..10)) · read-only · current The card's manufacturer hardware revision number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardServiceTag | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.9 | DisplayString (SIZE (0..7)) | RO | CWTQXC2 | |||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The card's service tag. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10CardExpServiceCode | 1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.10 | DisplayString (SIZE (0..14)) | RO | 281 062 707 86 | |||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The card's express service code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nos10SystemComponent | 1.3.6.1.4.1.674.11000.5000.100.4.1.2 | ||||||||||||||||||||
| Tos10PowerSupplyTable | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A list of power supplies resident in the device. | |||||||||||||||||||||
| Ros10PowerSupplyEntry | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current A power supply entry provides all attributes of that power supply.
| |||||||||||||||||||||
| Cos10PowerSupplyIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.1 | Unsigned32 | NA | ||||||||||||||||||
column · Unsigned32 · not-accessible · current The unique index of the power supply. | |||||||||||||||||||||
| Cos10PowerSupplyDevice | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.2 | Os10DeviceType | RO | 1 | |||||||||||||||||
column · Os10DeviceType · read-only · current Identify the type of device the power supply unit resides (chassis,line card etc..) Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10PowerSupplyDeviceIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.3 | Unsigned32 | RO | 1 | |||||||||||||||||
column · Unsigned32 · read-only · current A unique value indentifying a specific os10PowerSupplyDeviceType. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10PowerSupplyOperStatus | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4 | Os10CmnOperStatus | RO | 1 | |||||||||||||||||
column · Os10CmnOperStatus · read-only · current The status of the power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10PowerSupplyType | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.5 | INTEGER | RO | ac(2) | |||||||||||||||||
column · INTEGER · read-only · current The type of the power supply.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10PowerSupplyPPID | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.6 | DisplayString (SIZE (0..24)) | RO | CN03WVHP2829889I0CJM | |||||||||||||||||
column · DisplayString (SIZE (0..24)) · read-only · current The power supply's PPID. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10PowerSupplyServiceTag | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.7 | DisplayString (SIZE (0..7)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The power supply's service tag. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10PowerSupplyExpServiceCode | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.8 | DisplayString (SIZE (0..14)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The power supply's express service code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tos10FanTrayTable | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2 | NA | |||||||||||||||||||
table · not-accessible · current A list of fan trays resident in the device. | |||||||||||||||||||||
| Ros10FanTrayEntry | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1 | NA | |||||||||||||||||||
row · not-accessible · current A fan entry containing objects for a particular fan tray.
| |||||||||||||||||||||
| Cos10FanTrayIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.1 | Unsigned32 | NA | ||||||||||||||||||
column · Unsigned32 · not-accessible · current The unique index of the fan tray. | |||||||||||||||||||||
| Cos10FanTrayDevice | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.2 | Os10DeviceType | RO | 1 | |||||||||||||||||
column · Os10DeviceType · read-only · current Identify the type of device this fan tray unit resides (chassis,line card etc..) Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10FanTrayDeviceIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.3 | Unsigned32 | RO | 1 | |||||||||||||||||
column · Unsigned32 · read-only · current A unique value indentifying a specific os10FanTrayDevice. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10FanTrayOperStatus | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4 | Os10CmnOperStatus | RO | 1 | |||||||||||||||||
column · Os10CmnOperStatus · read-only · current The status of the fan tray. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10FanTrayPPID | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.5 | DisplayString (SIZE (0..24)) | RO | CN00YJWK282988AP0421 | |||||||||||||||||
| Cos10FanTrayServiceTag | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.6 | DisplayString (SIZE (0..7)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The fan tray's service tag. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10FanTrayExpServiceCode | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.7 | DisplayString (SIZE (0..14)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The fan tray's express service code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tos10FanTable | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3 | NA | |||||||||||||||||||
table · not-accessible · current A list of fans installed in the chassis. | |||||||||||||||||||||
| Ros10FanEntry | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1 | NA | |||||||||||||||||||
row · not-accessible · current A fan entry containing objects for a particular fan in the chassis.
| |||||||||||||||||||||
| Cos10FanIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.1 | Unsigned32 | NA | ||||||||||||||||||
column · Unsigned32 · not-accessible · current The unique value for each fan in the device. | |||||||||||||||||||||
| Cos10FanDevice | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.2 | Os10DeviceType | RO | 1 | |||||||||||||||||
column · Os10DeviceType · read-only · current Identify the type of device this fan resides. (chassis,line card etc..) Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10FanDeviceIndex | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.3 | Unsigned32 | RO | 1 | |||||||||||||||||
column · Unsigned32 · read-only · current A unique value indentifying a specific os10FanDevice. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10FanEntity | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.4 | INTEGER | RO | psu(1) | |||||||||||||||||
| Cos10FanEntitySlot | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.5 | Unsigned32 | RO | 1 | |||||||||||||||||
| Cos10FanId | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.6 | Unsigned32 | RO | 1 | |||||||||||||||||
column · Unsigned32 · read-only · current A unique value indentifying a specific fan in a specific os10FanEntity. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cos10FanOperStatus | 1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7 | Os10CmnOperStatus | RO | 1 | |||||||||||||||||
column · Os10CmnOperStatus · read-only · current The status of the fan. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nos10AlmObjects | 1.3.6.1.4.1.674.11000.5000.100.4.1.3 | ||||||||||||||||||||
| Nos10AlmMibNotifications | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1 | ||||||||||||||||||||
| !os10AlmMinorTempHigh | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.1 | ||||||||||||||||||||
notification · current The agent generates this trap when the chassis's temperature is exceeding the minor threshold. | |||||||||||||||||||||
| !os10AlmMinorTempClr | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.2 | ||||||||||||||||||||
notification · current The agent generates this trap when the chassis's temperature is within the minor threshold. | |||||||||||||||||||||
| !os10AlmMajorTempHigh | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.3 | ||||||||||||||||||||
notification · current The agent generates this trap when the chassis's temperature is exceeding the mjaor threshold. | |||||||||||||||||||||
| !os10AlmMajorTempClr | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.4 | ||||||||||||||||||||
notification · current The agent generates this trap when the chassis's temperature is within the mjaor threshold. | |||||||||||||||||||||
| !os10AlmPowerSupplyDown | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.5 | ||||||||||||||||||||
notification · current The agent generates this trap when a power supply is not operational. | |||||||||||||||||||||
| !os10AlmPowerSupplyClr | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.6 | ||||||||||||||||||||
notification · current The agent generates this trap when a power supply is now operational. | |||||||||||||||||||||
| !os10AlmMajorPowerSupply | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.7 | ||||||||||||||||||||
notification · current The agent generates this trap when a power supply major alarm is issued. | |||||||||||||||||||||
| !os10AlmMajorPowerSupplyClr | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.8 | ||||||||||||||||||||
notification · current The agent generates this trap when a power supply major alarm is cleared. | |||||||||||||||||||||
| !os10AlmMinorPowerSupply | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.9 | ||||||||||||||||||||
notification · current The agent generates this trap when a power supply minor alarm is issued. | |||||||||||||||||||||
| !os10AlmMinorPowerSupplyClr | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.10 | ||||||||||||||||||||
notification · current The agent generates this trap when a power supply minor alarm is cleared. | |||||||||||||||||||||
| !os10AlmFanTrayDown | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.11 | ||||||||||||||||||||
notification · current The agent generates this trap when a fan tray is missing or not operational. | |||||||||||||||||||||
| !os10AlmFanTrayClr | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.12 | ||||||||||||||||||||
notification · current The agent generates this trap when a fan tray is now operational. | |||||||||||||||||||||
| !os10AlmMinorFanTray | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.13 | ||||||||||||||||||||
notification · current The agent generates this trap when a minor fan tray alarm is issued. | |||||||||||||||||||||
| !os10AlmMinorFanTrayClr | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.14 | ||||||||||||||||||||
notification · current The agent generates this trap when a theminor fan tray alarm is cleared. | |||||||||||||||||||||
| Nos10AlmVariable | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2 | ||||||||||||||||||||
| Sos10AlmVarInteger | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.1 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current An generic integer value in the TRAP object | |||||||||||||||||||||
| Sos10AlmVarString | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.2 | OCTET STRING (SIZE (0..255)) | AN | ||||||||||||||||||
scalar · OCTET STRING (SIZE (0..255)) · accessible-for-notify · current An generic string value in the TRAP object | |||||||||||||||||||||
| Sos10AlmVarChassisId | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.3 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The Chassis ID. For the traps that does not have Chassis information the value will be -1 in the TRAP PDU. For Non-ON based platforms, the value is 0 based and for ON Based platform it is 1 based in the Trap PDU. | |||||||||||||||||||||
| Sos10AlmVarSlot | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.4 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The chassis slot number. For the traps that does not have slot information the value will -1 in the TRAP PDU. | |||||||||||||||||||||
| Sos10AlmVarPort | 1.3.6.1.4.1.674.11000.5000.100.4.1.3.2.5 | Integer32 | AN | ||||||||||||||||||
scalar · Integer32 · accessible-for-notify · current The chassis port number. For the traps that does not have port information the value will -1 in the TRAP PDU. | |||||||||||||||||||||
Traps / Notifications
- os10AlmFanTrayClr
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.12 - os10AlmFanTrayDown
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.11 - os10AlmMajorPowerSupply
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.7 - os10AlmMajorPowerSupplyClr
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.8 - os10AlmMajorTempClr
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.4 - os10AlmMajorTempHigh
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.3 - os10AlmMinorFanTray
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.13 - os10AlmMinorFanTrayClr
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.14 - os10AlmMinorPowerSupply
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.9 - os10AlmMinorPowerSupplyClr
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.10 - os10AlmMinorTempClr
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.2 - os10AlmMinorTempHigh
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.1 - os10AlmPowerSupplyClr
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.6 - os10AlmPowerSupplyDown
1.3.6.1.4.1.674.11000.5000.100.4.1.3.1.5