DELL-RAC-MIB
Dell Inc.snmptranslate -m DELL-RAC-MIB -Tpsnmpwalk -v2c -c <community> -m DELL-RAC-MIB <host> 1.3.6.1.4.1.674Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ndell | 1.3.6.1.4.1.674 | ||||||||||||||||||||
| Nserver3 | 1.3.6.1.4.1.674.10892 | ||||||||||||||||||||
| NdrsOutofBandGroup | 1.3.6.1.4.1.674.10892.2 | ||||||||||||||||||||
| !alertDrscTestTrapEvent | 1.3.6.1.4.1.674.10892.2.0.1001 | ||||||||||||||||||||
notification The RAC generated a test trap event in response to a user request. | |||||||||||||||||||||
| !alertDrscAuthError | 1.3.6.1.4.1.674.10892.2.0.1002 | ||||||||||||||||||||
notification The RAC Authentication Failures during a time period have Exceeded a Threshold. | |||||||||||||||||||||
| !alertDrscLostESM | 1.3.6.1.4.1.674.10892.2.0.1003 | ||||||||||||||||||||
notification The RAC cannot communicate with the baseboard management controller (ESM). | |||||||||||||||||||||
| !alertDrscFoundESM | 1.3.6.1.4.1.674.10892.2.0.1004 | ||||||||||||||||||||
notification The RAC is communicating normally with the baseboard management controller (ESM). | |||||||||||||||||||||
| !alertDrscPowerOff | 1.3.6.1.4.1.674.10892.2.0.1005 | ||||||||||||||||||||
notification The RAC has detected a System power state change to powered-off. | |||||||||||||||||||||
| !alertDrscPowerOn | 1.3.6.1.4.1.674.10892.2.0.1006 | ||||||||||||||||||||
notification The RAC has detected a system power state change to powered-on. | |||||||||||||||||||||
| !alertDrscWatchdogExpired | 1.3.6.1.4.1.674.10892.2.0.1007 | ||||||||||||||||||||
notification The RAC has detected that the system watchdog has expired indicating a system hang. | |||||||||||||||||||||
| !alertDrscBattLow | 1.3.6.1.4.1.674.10892.2.0.1008 | ||||||||||||||||||||
notification The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes. | |||||||||||||||||||||
| !alertDrscTempNormal | 1.3.6.1.4.1.674.10892.2.0.1009 | ||||||||||||||||||||
notification The RAC Temperature probe has retured to a normal value. | |||||||||||||||||||||
| !alertDrscTempWarning | 1.3.6.1.4.1.674.10892.2.0.1010 | ||||||||||||||||||||
notification The RAC Temperature probe has detected a Warning value. | |||||||||||||||||||||
| !alertDrscTempCritical | 1.3.6.1.4.1.674.10892.2.0.1011 | ||||||||||||||||||||
notification The RAC Temperature probe has detected a failure (or critical) value. | |||||||||||||||||||||
| !alertDrscVoltNormal | 1.3.6.1.4.1.674.10892.2.0.1012 | ||||||||||||||||||||
notification The RAC voltage has returned to a normal value. | |||||||||||||||||||||
| !alertDrscVoltWarning | 1.3.6.1.4.1.674.10892.2.0.1013 | ||||||||||||||||||||
notification The RAC voltage probe has detected a warning value. | |||||||||||||||||||||
| !alertDrscVoltCritical | 1.3.6.1.4.1.674.10892.2.0.1014 | ||||||||||||||||||||
notification The RAC voltage probe has detected a failure (or critical) value. | |||||||||||||||||||||
| !alertDrscSELWarning | 1.3.6.1.4.1.674.10892.2.0.1015 | ||||||||||||||||||||
notification The RAC has detected a new event in the System Event Log with Severity: Warning. | |||||||||||||||||||||
| !alertDrscSELCritical | 1.3.6.1.4.1.674.10892.2.0.1016 | ||||||||||||||||||||
notification The RAC has detected a new event in the System Event Log with Severity: Critical. | |||||||||||||||||||||
| !alertDrscSEL80percentFull | 1.3.6.1.4.1.674.10892.2.0.1017 | ||||||||||||||||||||
notification The RAC has detected that the System Event Log is 80% full. | |||||||||||||||||||||
| !alertDrscSEL90percentFull | 1.3.6.1.4.1.674.10892.2.0.1018 | ||||||||||||||||||||
notification The RAC has detected that the System Event Log is 90% full. | |||||||||||||||||||||
| !alertDrscSEL100percentFull | 1.3.6.1.4.1.674.10892.2.0.1019 | ||||||||||||||||||||
notification The RAC has detected that the System Event Log is 100% full. | |||||||||||||||||||||
| !alertDrscSELNormal | 1.3.6.1.4.1.674.10892.2.0.1020 | ||||||||||||||||||||
notification The RAC has detected a new event in the System Event Log with Severity: Normal. | |||||||||||||||||||||
| !alertCMCTestTrap | 1.3.6.1.4.1.674.10892.2.0.2000 | ||||||||||||||||||||
notification The CMC has generated a test trap | |||||||||||||||||||||
| !alertCMCNormalTrap | 1.3.6.1.4.1.674.10892.2.0.2002 | ||||||||||||||||||||
notification The CMC reported a return-to-normal or informational event. | |||||||||||||||||||||
| !alertCMCWarningTrap | 1.3.6.1.4.1.674.10892.2.0.2003 | ||||||||||||||||||||
notification The CMC reported a warning event. | |||||||||||||||||||||
| !alertCMCCriticalTrap | 1.3.6.1.4.1.674.10892.2.0.2004 | ||||||||||||||||||||
notification The CMC reported a critical event. | |||||||||||||||||||||
| !alertCMCNonRecoverableTrap | 1.3.6.1.4.1.674.10892.2.0.2005 | ||||||||||||||||||||
notification The CMC reported a catastrophic event. | |||||||||||||||||||||
| NdrsInformationGroup | 1.3.6.1.4.1.674.10892.2.1 | ||||||||||||||||||||
| NdrsProductInfoGroup | 1.3.6.1.4.1.674.10892.2.1.1 | ||||||||||||||||||||
| SdrsProductName | 1.3.6.1.4.1.674.10892.2.1.1.1 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0001 This attribute defines the product name of a chassis management controller. | |||||||||||||||||||||
| SdrsProductShortName | 1.3.6.1.4.1.674.10892.2.1.1.2 | DellString | RO | mandatory | iDRAC | ||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0002 This attribute defines the short product name of a chassis management controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsProductDescription | 1.3.6.1.4.1.674.10892.2.1.1.3 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0003 This attribute defines the product description of a chassis management controller. | |||||||||||||||||||||
| SdrsProductManufacturer | 1.3.6.1.4.1.674.10892.2.1.1.4 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. | |||||||||||||||||||||
| SdrsProductVersion | 1.3.6.1.4.1.674.10892.2.1.1.5 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0005 This attribute defines the product version of a chassis management controller. | |||||||||||||||||||||
| SdrsChassisServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.6 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0007 This attribute defines the Service Tag of the chassis. | |||||||||||||||||||||
| SdrsProductURL | 1.3.6.1.4.1.674.10892.2.1.1.7 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. | |||||||||||||||||||||
| SdrsProductChassisAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.8 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0008 This attribute defines the Asset Tag of the chassis. | |||||||||||||||||||||
| SdrsProductChassisLocation | 1.3.6.1.4.1.674.10892.2.1.1.9 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0009 This attribute defines the location of the chassis. | |||||||||||||||||||||
| SdrsProductChassisName | 1.3.6.1.4.1.674.10892.2.1.1.10 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0010 This attribute defines the name of the chassis. | |||||||||||||||||||||
| SdrsSystemServiceTag | 1.3.6.1.4.1.674.10892.2.1.1.11 | DellString | RO | mandatory | 8WM8ST3 | ||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0011 This attribute defines the service tag of a system. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsProductSystemAssetTag | 1.3.6.1.4.1.674.10892.2.1.1.12 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0012 This attribute defines the asset tag of a system. | |||||||||||||||||||||
| SdrsProductSystemSlot | 1.3.6.1.4.1.674.10892.2.1.1.13 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0013 This attribute defines the slot number of a CMC. | |||||||||||||||||||||
| SdrsProductType | 1.3.6.1.4.1.674.10892.2.1.1.14 | DellRacType | RO | mandatory | |||||||||||||||||
scalar · DellRacType · read-only · mandatory 0001.0001.0014 This attribute defines type of a remote access card | |||||||||||||||||||||
| SdrsProductChassisDataCenter | 1.3.6.1.4.1.674.10892.2.1.1.15 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0015 This attribute defines the Data Center locator of the chassis. | |||||||||||||||||||||
| SdrsProductChassisAisle | 1.3.6.1.4.1.674.10892.2.1.1.16 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0016 This attribute defines the Aisle locator of the chassis. | |||||||||||||||||||||
| SdrsProductChassisRack | 1.3.6.1.4.1.674.10892.2.1.1.17 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0017 This attribute defines the Rack locator of the chassis. | |||||||||||||||||||||
| SdrsProductChassisRackSlot | 1.3.6.1.4.1.674.10892.2.1.1.18 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. | |||||||||||||||||||||
| SdrsProductChassisModel | 1.3.6.1.4.1.674.10892.2.1.1.19 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0019 This attribute defines the Model of the chassis. | |||||||||||||||||||||
| SdrsProductChassisExpressServiceCode | 1.3.6.1.4.1.674.10892.2.1.1.20 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0001.0020 This attribute defines the Express Service Code of the chassis. | |||||||||||||||||||||
| SdrsProductChassisSystemID | 1.3.6.1.4.1.674.10892.2.1.1.21 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory 0001.0001.0021 This attribute defines the System ID of the chassis. | |||||||||||||||||||||
| SdrsProductChassisSize | 1.3.6.1.4.1.674.10892.2.1.1.22 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory 0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component. | |||||||||||||||||||||
| NdrsFirmwareGroup | 1.3.6.1.4.1.674.10892.2.1.2 | ||||||||||||||||||||
| SdrsFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.1 | DellString | RO | mandatory | 7.10.30.00 | ||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0002.0001 This attribute defines the firmware version of chassis management controller 1. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsiKVMFirmwareVersion | 1.3.6.1.4.1.674.10892.2.1.2.2 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0002.0002 This attribute defines the firmware version of the iKVM. | |||||||||||||||||||||
| SdrsFirmwareVersion2 | 1.3.6.1.4.1.674.10892.2.1.2.3 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0001.0002.0003 This attribute defines the firmware version of chassis management controller 2. | |||||||||||||||||||||
| NdrsStatusGroup | 1.3.6.1.4.1.674.10892.2.2 | ||||||||||||||||||||
| SdrsGlobalSystemStatus | 1.3.6.1.4.1.674.10892.2.2.1 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NdrsChassisStatusGroup | 1.3.6.1.4.1.674.10892.2.3 | ||||||||||||||||||||
| NdrsStatusNowGroup | 1.3.6.1.4.1.674.10892.2.3.1 | ||||||||||||||||||||
| SdrsGlobalCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.1 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card. | |||||||||||||||||||||
| SdrsIOMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.2 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsKVMCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.3 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsRedCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.4 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsPowerCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.5 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsFanCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.6 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsBladeCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.7 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsTempCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.8 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsCMCCurrStatus | 1.3.6.1.4.1.674.10892.2.3.1.9 | DellStatus | RO | mandatory | 3 | ||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsChassisFrontPanelAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.10 | DellTemperatureReading | RO | mandatory | 18 | ||||||||||||||||
scalar · DellTemperatureReading · read-only · mandatory 0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsCMCAmbientTemperature | 1.3.6.1.4.1.674.10892.2.3.1.11 | DellTemperatureReading | RO | mandatory | 31 | ||||||||||||||||
scalar · DellTemperatureReading · read-only · mandatory 0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SdrsCMCProcessorTemperature | 1.3.6.1.4.1.674.10892.2.3.1.12 | DellTemperatureReading | RO | mandatory | 28 | ||||||||||||||||
scalar · DellTemperatureReading · read-only · mandatory 0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NdrsStatusPrevGroup | 1.3.6.1.4.1.674.10892.2.3.2 | ||||||||||||||||||||
| SdrsGlobalPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.1 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card. | |||||||||||||||||||||
| SdrsIOMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.2 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card. | |||||||||||||||||||||
| SdrsKVMPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.3 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card. | |||||||||||||||||||||
| SdrsRedPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.4 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card. | |||||||||||||||||||||
| SdrsPowerPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.5 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card. | |||||||||||||||||||||
| SdrsFanPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.6 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card. | |||||||||||||||||||||
| SdrsBladePrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.7 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card. | |||||||||||||||||||||
| SdrsTempPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.8 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card. | |||||||||||||||||||||
| SdrsCMCPrevStatus | 1.3.6.1.4.1.674.10892.2.3.2.9 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card. | |||||||||||||||||||||
| NdrsStatusChangeGroup | 1.3.6.1.4.1.674.10892.2.3.3 | ||||||||||||||||||||
| SdrsGlobalChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.1 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0001 This attribute defines the timestamp of the most recent global status change. | |||||||||||||||||||||
| SdrsIOMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.2 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change. | |||||||||||||||||||||
| SdrsKVMChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.3 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change. | |||||||||||||||||||||
| SdrsRedChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.4 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change. | |||||||||||||||||||||
| SdrsPowerChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.5 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0005 This attribute defines the timestamp of the most recent power health status change. | |||||||||||||||||||||
| SdrsFanChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.6 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change. | |||||||||||||||||||||
| SdrsBladeChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.7 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change. | |||||||||||||||||||||
| SdrsTempChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.8 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change. | |||||||||||||||||||||
| SdrsCMCChangeTime | 1.3.6.1.4.1.674.10892.2.3.3.9 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change. | |||||||||||||||||||||
| NdrsChassisPowerGroup | 1.3.6.1.4.1.674.10892.2.4 | ||||||||||||||||||||
| TdrsCMCPowerTable | 1.3.6.1.4.1.674.10892.2.4.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory 0004.0001 This object defines the CMC power table. | |||||||||||||||||||||
| RdrsCMCPowerTableEntry | 1.3.6.1.4.1.674.10892.2.4.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory 0004.0001.0001 This object defines the CMC power table entry.
| |||||||||||||||||||||
| CdrsChassisIndex | 1.3.6.1.4.1.674.10892.2.4.1.1.1 | DellCMCPowerIndexRange | RO | mandatory | 1 | ||||||||||||||||
column · DellCMCPowerIndexRange · read-only · mandatory 0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPotentialPower | 1.3.6.1.4.1.674.10892.2.4.1.1.2 | DellPowerReading | RO | mandatory | 6459.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsIdlePower | 1.3.6.1.4.1.674.10892.2.4.1.1.3 | DellPowerReading | RO | mandatory | 1721.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsMaxPowerSpecification | 1.3.6.1.4.1.674.10892.2.4.1.1.4 | DellPowerReading | RO | mandatory | 12514.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPowerSurplus | 1.3.6.1.4.1.674.10892.2.4.1.1.5 | DellPowerReading | RO | mandatory | 6055.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsKWhCumulative | 1.3.6.1.4.1.674.10892.2.4.1.1.6 | DellPowerReading | RO | mandatory | 42470.004 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsKWhCumulativeTime | 1.3.6.1.4.1.674.10892.2.4.1.1.7 | DellTimestamp | RO | mandatory | 20130307085222.000000+000 | ||||||||||||||||
column · DellTimestamp · read-only · mandatory 0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsWattsPeakUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.8 | DellPowerReading | RO | mandatory | 4803.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsWattsPeakTime | 1.3.6.1.4.1.674.10892.2.4.1.1.9 | DellTimestamp | RO | mandatory | 20181211131605.000000+000 | ||||||||||||||||
column · DellTimestamp · read-only · mandatory 0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsWattsMinUsage | 1.3.6.1.4.1.674.10892.2.4.1.1.10 | DellPowerReading | RO | mandatory | 57.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsWattsMinTime | 1.3.6.1.4.1.674.10892.2.4.1.1.11 | DellTimestamp | RO | mandatory | 20190517131723.000000+000 | ||||||||||||||||
column · DellTimestamp · read-only · mandatory 0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsWattsResetTime | 1.3.6.1.4.1.674.10892.2.4.1.1.12 | DellTimestamp | RO | mandatory | 20181206170518.000000+000 | ||||||||||||||||
column · DellTimestamp · read-only · mandatory 0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsWattsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.13 | DellPowerReading | RO | mandatory | 1721.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts). Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsAmpsReading | 1.3.6.1.4.1.674.10892.2.4.1.1.14 | DellPowerReading | RO | mandatory | 7.744 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts). Example values from LibreNMS test devices
| |||||||||||||||||||||
| TdrsCMCPSUTable | 1.3.6.1.4.1.674.10892.2.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory 0004.0002 This object defines the CMC PSU table. | |||||||||||||||||||||
| RdrsCMCPSUTableEntry | 1.3.6.1.4.1.674.10892.2.4.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory 0004.0002.0001 This object defines the CMC PSU table entry. | |||||||||||||||||||||
| CdrsPSUChassisIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.1 | DellCMCPowerIndexRange | RO | mandatory | 1 | ||||||||||||||||
column · DellCMCPowerIndexRange · read-only · mandatory 0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPSUIndex | 1.3.6.1.4.1.674.10892.2.4.2.1.2 | DellCMCPSUIndexRange | RO | mandatory | 1 | ||||||||||||||||
column · DellCMCPSUIndexRange · read-only · mandatory 0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPSULocation | 1.3.6.1.4.1.674.10892.2.4.2.1.3 | DellString | RO | mandatory | PS-1 | ||||||||||||||||
column · DellString · read-only · mandatory 0004.0002.0001.0003 This attribute defines the location of the CMC PSU. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPSUMonitoringCapable | 1.3.6.1.4.1.674.10892.2.4.2.1.4 | DellCMCPSUCapable | RO | mandatory | 3 | ||||||||||||||||
column · DellCMCPSUCapable · read-only · mandatory 0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPSUVoltsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.5 | DellPowerReading | RO | mandatory | 243.500 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPSUAmpsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.6 | DellPowerReading | RO | mandatory | 1.281 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsPSUWattsReading | 1.3.6.1.4.1.674.10892.2.4.2.1.7 | DellPowerReading | RO | mandatory | 2700.000 | ||||||||||||||||
column · DellPowerReading · read-only · mandatory 0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NdrsChassisServerGroup | 1.3.6.1.4.1.674.10892.2.5 | ||||||||||||||||||||
| TdrsCMCServerTable | 1.3.6.1.4.1.674.10892.2.5.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory 0005.0001 This object defines the CMC server table. | |||||||||||||||||||||
| RdrsCMCServerTableEntry | 1.3.6.1.4.1.674.10892.2.5.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory 0005.0001.0001 This object defines the CMC server table entry.
| |||||||||||||||||||||
| CdrsServerIndex | 1.3.6.1.4.1.674.10892.2.5.1.1.1 | DellCMCServerIndexRange | RO | mandatory | 1 | ||||||||||||||||
column · DellCMCServerIndexRange · read-only · mandatory 0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerMonitoringCapable | 1.3.6.1.4.1.674.10892.2.5.1.1.2 | DellCMCServerCapable | RO | mandatory | 3 | ||||||||||||||||
column · DellCMCServerCapable · read-only · mandatory 0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerServiceTag | 1.3.6.1.4.1.674.10892.2.5.1.1.3 | DellString | RO | mandatory | 64V8NX2 | ||||||||||||||||
column · DellString · read-only · mandatory 0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerSlotName | 1.3.6.1.4.1.674.10892.2.5.1.1.4 | DellString | RO | mandatory | SLOT-01 | ||||||||||||||||
column · DellString · read-only · mandatory 0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerSlotNumber | 1.3.6.1.4.1.674.10892.2.5.1.1.5 | DellString | RO | mandatory | 1 | ||||||||||||||||
column · DellString · read-only · mandatory 0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerNodeID | 1.3.6.1.4.1.674.10892.2.5.1.1.6 | DellString | RO | mandatory | 64V8NX2 | ||||||||||||||||
column · DellString · read-only · mandatory 0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerModel | 1.3.6.1.4.1.674.10892.2.5.1.1.7 | DellString | RO | mandatory | PowerEdge M640 (VRTX) | ||||||||||||||||
column · DellString · read-only · mandatory 0005.0001.0001.0007 This attribute defines the Model of the CMC server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerAssetTag | 1.3.6.1.4.1.674.10892.2.5.1.1.8 | DellString | RO | mandatory | N/A | ||||||||||||||||
column · DellString · read-only · mandatory 0005.0001.0001.0008 This attribute defines the Asset Tag of the CMC server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerNumStorageControllers | 1.3.6.1.4.1.674.10892.2.5.1.1.9 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory 0005.0001.0001.0009 This attribute defines the number of storage controllers on the storage sled. The value will be zero if this is not a storage sled. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerStorageMode | 1.3.6.1.4.1.674.10892.2.5.1.1.10 | DellCMCServerStorageMode | RO | mandatory | 1 | ||||||||||||||||
column · DellCMCServerStorageMode · read-only · mandatory 0005.0001.0001.0010 This attribute defines the Storage Mode of the storage sled. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerIntrusionState | 1.3.6.1.4.1.674.10892.2.5.1.1.11 | DellCMCServerIntrusionState | RO | mandatory | 1 | ||||||||||||||||
column · DellCMCServerIntrusionState · read-only · mandatory 0005.0001.0001.0011 This attribute defines the Intrusion State of the CMC server if supported by the server. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdrsServerAssignedServerSlots | 1.3.6.1.4.1.674.10892.2.5.1.1.12 | DellString | RO | mandatory | N/A | ||||||||||||||||
column · DellString · read-only · mandatory 0005.0001.0001.0012 This attribute defines the the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or more server slots, the value will be a comma-separated list of one or more server slot names. If the storage sled is not assigned to a server slot, the value will be an empty string. If this is not a storage sled, the value will be N/A. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NstorageDetailsGroup | 1.3.6.1.4.1.674.10892.2.6 | ||||||||||||||||||||
| Nsoftware | 1.3.6.1.4.1.674.10892.2.6.1 | ||||||||||||||||||||
| NstorageManagement | 1.3.6.1.4.1.674.10892.2.6.1.20 | ||||||||||||||||||||
| NphysicalDevices | 1.3.6.1.4.1.674.10892.2.6.1.20.130 | ||||||||||||||||||||
| TcontrollerTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed RAID controllers. The number of entries is related to number of RAID controllers discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RcontrollerTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CcontrollerNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.1 | INTEGER (0..255) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Instance number of this controller entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.2 | DisplayString | RO | mandatory | Shared PERC8 (Embedded) | ||||||||||||||||
column · DisplayString · read-only · mandatory The controller's name as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerRebuildRate | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.7 | INTEGER (0..100) | RO | mandatory | 30 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerFWVersion | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.8 | DisplayString | RO | mandatory | 23.14.06.0013 | ||||||||||||||||
column · DisplayString · read-only · mandatory The controller's current firmware version. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCacheSizeInMB | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.9 | INTEGER | RO | mandatory | 1024 | ||||||||||||||||
column · INTEGER · read-only · mandatory The controller's current amount of cache memory in megabytes. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerRollUpStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.37 | ObjectStatusEnum | RO | mandatory | 3 | ||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory Severity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other. 2: Unknown. 3: OK 4: Non-critical 5: Critical. 6: Non-recoverable. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.38 | ObjectStatusEnum | RO | mandatory | 3 | ||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerDriverVersion | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.41 | DisplayString | RO | mandatory | 06.805.01.00 | ||||||||||||||||
column · DisplayString · read-only · mandatory Currently installed driver version for this controller on the host. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPCISlot | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.42 | DisplayString | RO | mandatory | Embedded | ||||||||||||||||
column · DisplayString · read-only · mandatory The PCI slot on the server where the controller is seated. This data is not reported for embedded or integrated controllers, Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerReconstructRate | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.48 | INTEGER (0..100) | RO | mandatory | 30 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The reconstruct rate is the percentage of the controller's resources dedicated to reconstructing a disk group after adding a physical disk or changing the RAID level of a virtual disk residing on the disk group. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPatrolReadRate | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.49 | INTEGER (0..100) | RO | mandatory | 30 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerBGIRate | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.50 | INTEGER (0..100) | RO | mandatory | 30 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant virtual disk after it is created. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCheckConsistencyRate | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.51 | INTEGER (0..100) | RO | mandatory | 30 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPatrolReadMode | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.52 | INTEGER | RO | mandatory | disabled(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory Identifies the patrol read mode setting for the controller. Possible values: 1: Not one of the following or could not be determined. 2: Not Supported on this controller. 3: Disabled. 4: Automatic. 5: Manual.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPatrolReadState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.53 | INTEGER | RO | mandatory | stopped(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory This property displays the current state of the patrol read process. Possible values: 1: Not one of the following or could not be determined. 2: Patrol read is not running. 3: Patrol read is running.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPersistentHotSpare | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.59 | BooleanType | RO | mandatory | 0 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether hot spare drives would be restored on insertion into the same slot. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSpinDownUnconfiguredDrives | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.60 | BooleanType | RO | mandatory | 0 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether un-configured drives would be put in power save mode by the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSpinDownHotSpareDrives | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.61 | BooleanType | RO | mandatory | 0 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether hot spare drives would be put in power save mode by the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSpinDownTimeInterval | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.62 | INTEGER (30..1440) | RO | mandatory | 30 | ||||||||||||||||
column · INTEGER (30..1440) · read-only · mandatory The duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPreservedCache | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.69 | BooleanType | RO | mandatory | 0 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether preserved cache or pinned cache is present on the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCheckConsistencyMode | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.70 | INTEGER | RO | mandatory | normal(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory The current check consistency mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Normal check consistency operation. 4: Check consistency operation will stop on encountering an error.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerCopyBackMode | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.71 | INTEGER | RO | mandatory | on(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory The current copy back mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Disks assigned as spares could revert back to spare status. 4: Data from physical disk participating in a virtual disk could be automatically copied to the assigned hot spare in case former has a predictive failure event. 5: Copyback mode is disabled.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSecurityStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.72 | INTEGER | RO | mandatory | none(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory The controller's current security/encryption status.. Possible values: 1: The current status could not be determined. 2: Controller is not operating in an encryption mode. 3: Controller is operating in the Local Key Management (LKM) encryption mode.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerEncryptionKeyPresent | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.73 | BooleanType | RO | mandatory | 0 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether encryption key is assigned for the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerEncryptionCapability | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.74 | INTEGER | RO | mandatory | lkm(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory The type of encryption supported by the controller. Possible values: 1: Not one of the following. 2: No encryption supported, 3: Local Key Management,
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerLoadBalanceSetting | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.75 | INTEGER | RO | mandatory | auto(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory The ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possible values: 1: Not one of the following. 2: Not supported. 3: Automatic load balancing is active. 4: Load balancing is inactive.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerMaxCapSpeed | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.76 | INTEGER | RO | mandatory | sixGbps(4) | ||||||||||||||||
column · INTEGER · read-only · mandatory The maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerSASAddress | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.77 | DisplayString | RO | mandatory | 0x54CD98F068022400 | ||||||||||||||||
column · DisplayString · read-only · mandatory The SAS address of the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.78 | FQDDString | RO | mandatory | RAID.ChassisIntegrated.2-1 | ||||||||||||||||
column · FQDDString · read-only · mandatory The controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.79 | DisplayString | RO | mandatory | Chassis Integrated RAID 2 | ||||||||||||||||
column · DisplayString · read-only · mandatory The controller's friendly FQDD as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerT10PICapability | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.80 | INTEGER | RO | mandatory | notCapable(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Capable of supporting T10 PI. 3: Not capable of supporting T10 PI.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerRAID10UnevenSpansSupported | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.81 | BooleanType | RO | mandatory | 0 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether uneven spans for RAID 10 virtual disk is supported on the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerEnhancedAutoImportForeignConfigMode | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.82 | INTEGER | RO | mandatory | enabled(4) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the status of enhanced auto-import of foreign configuration property of the controller. 1: Not one of the following. 2: Not Supported. 3: Disabled. 4: Enabled.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerBootModeSupported | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.83 | BooleanType | RO | mandatory | 1 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether headless boot mode settings are supported on the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerBootMode | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.84 | INTEGER | RO | mandatory | headlessContOnError(4) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the boot mode of the controller. Possible values: 1: Not applicable for this controller. 2: User mode: User interaction required for all boot messages (not applicable for uEFI environments). 3: Continue Boot On Error. User interaction only required for critical messages. 4: Headless Mode Continue On Error. User interaction is not required. Controller boot may halt on Error. 5: Headless Safe Mode. Controller shall boot to safe mode on critical errors.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerHighAvailabilityMode | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.85 | INTEGER | RO | mandatory | faultTolerantActivePassive(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the fault-tolerant mode of the controller. Possible values: 1: None 2: Fault Tolerant(Active/Passive) 3: Fault Tolerant(Active/Active) 4: Degraded
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerPeerController | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.86 | FQDDString | RO | mandatory | RAID.ChassisIntegrated.1-1 | ||||||||||||||||
column · FQDDString · read-only · mandatory The peer controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcontrollerEncryptionKeyIdentifier | 1.3.6.1.4.1.674.10892.2.6.1.20.130.1.1.87 | DisplayString | RO | mandatory | Not Applicable | ||||||||||||||||
column · DisplayString · read-only · mandatory Displays the encryption security key identifier of the controller, if the controller is encryption enabled and a security key is configured for the controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TenclosureTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed enclosures/backplanes. The number of entries is related to number of internal backplane(s) discovered in the system and external storage enclosure(s) attached to the system.. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the enclosure table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CenclosureNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Instance number of this enclossre/backplane. | |||||||||||||||||||||
| CenclosureName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The enclosure/backplane's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current state of this enclosure/backplane. Possible states: 1: The current state could not be determined. 2: The enclosure is operating normally. 3: The enclosure has encountered a hardware problem or is not responding. 4: The enclosure is no longer connected to the controller or there exists a problem communicating to the enclosure. 5: The enclosure is unstable. 6: The enclosure is inactive due to being configured by another controller. 7: The enclosure is offline and inaccessible. 8: The enclosure is online and accessible. 9: The enclosure is currently blocked by another controller.
| |||||||||||||||||||||
| CenclosureServiceTag | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Enclosure identification used when consulting customer support. | |||||||||||||||||||||
| CenclosureAssetTag | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The asset tag information for the enclosure. | |||||||||||||||||||||
| CenclosureConnectedPort | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.19 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The port on the controller to which the storage enclosure is connected. | |||||||||||||||||||||
| CenclosureRollUpStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.23 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory Severity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical. 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.24 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the enclosure/backplane.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureFirmwareVersion | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.26 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The firmware information for the enclosure/backplane. | |||||||||||||||||||||
| CenclosureSASAddress | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.30 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The SAS address of the enclosure/backplane. | |||||||||||||||||||||
| CenclosureDriveCount | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.31 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of disks present in the enclosure/backplane. | |||||||||||||||||||||
| CenclosureTotalSlots | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.32 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The total physical drive slots in a storage enclosure or server backplane. | |||||||||||||||||||||
| CenclosureFanCount | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.40 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The number of fans present in the storage enclosure. | |||||||||||||||||||||
| CenclosurePSUCount | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.41 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The number of Power Supply Units (PSU) present in the storage enclosure. | |||||||||||||||||||||
| CenclosureEMMCount | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.42 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The number of Enclosure Management Modules (EMM) present in the storage enclosure. | |||||||||||||||||||||
| CenclosureTempProbeCount | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.43 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The number of temperature sensing devices present in the storage enclosure. | |||||||||||||||||||||
| CenclosureRedundantPath | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.44 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates whether the controller has multiply paths to reach the storage enclosure. | |||||||||||||||||||||
| CenclosurePosition | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.45 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The possition of the storage enclosure within a daisy chain. | |||||||||||||||||||||
| CenclosureBackplaneBayID | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.46 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The unique bay ID of the backplane. | |||||||||||||||||||||
| CenclosureFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.47 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory The enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.48 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The enclosure/backplane's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| CenclosureType | 1.3.6.1.4.1.674.10892.2.6.1.20.130.3.1.49 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The protocol supported by the backplane. Possible states: 1: Not one of the following or could not be determined. 2: Not applicable (i.e. object is not a backplane). 3: Supports SAS/SATA. 4: Supports PCIe. 5: Both SAS/SATA and PCIe.
| |||||||||||||||||||||
| TphysicalDiskTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed physical disks. The number of entries is related to number of physical Disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RphysicalDiskTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the physical Disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CphysicalDiskNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.1 | INTEGER (0..1000000000) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (0..1000000000) · read-only · mandatory Instance number of this physical disk entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.2 | DisplayString | RO | mandatory | Physical Disk 0:0:4 | ||||||||||||||||
column · DisplayString · read-only · mandatory The physical disk's name as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufacturer | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.3 | DisplayString | RO | mandatory | TOSHIBA | ||||||||||||||||
column · DisplayString · read-only · mandatory The name of the physical disk's manufacturer. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.4 | INTEGER | RO | mandatory | online(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory The current state of this physical disk. Possible states: 1: The current state could not be determined. 2: The physical disk is available for use, but no RAID configuration has been assigned. 3: A RAID configuration has been assigned to the physical disk. 4: The physical disk has been moved from another controller and contains all or some portion of a virtual disk. 5: The physical disk is not available to the RAID controller. 6: The physical disk is currently blocked by controller. 7: The physical disk is not operational. 8: The physical disk is not a RAID capable disk 9: The physical disk has been removed. 10:The physical disk media has been placed in read only mode.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskProductID | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.6 | DisplayString | RO | mandatory | AL15SEB120NY | ||||||||||||||||
column · DisplayString · read-only · mandatory The model number of the physical disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSerialNo | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.7 | DisplayString | RO | mandatory | 39M0A0MEFQVF | ||||||||||||||||
column · DisplayString · read-only · mandatory The physical disk's unique identification number from the manufacturer. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskRevision | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.8 | DisplayString | RO | mandatory | EF03 | ||||||||||||||||
column · DisplayString · read-only · mandatory The firmware version of the physical disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskCapacityInMB | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.11 | INTEGER | RO | mandatory | 1144064 | ||||||||||||||||
column · INTEGER · read-only · mandatory The size of the physical disk in megabytes. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskUsedSpaceInMB | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.17 | INTEGER | RO | mandatory | 1144064 | ||||||||||||||||
column · INTEGER · read-only · mandatory The amount of used space in megabytes on the physical disk. This is not applicable for NVMe devices. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskFreeSpaceInMB | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.19 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory The amount of free space in megabytes on the physical disk. This is not applicable for NVMe devices. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskBusType | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.21 | INTEGER | RO | mandatory | sas(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory The bus type of the physical disk. Possible values: 1: The bus type could not be determined. 2: Small Computer System Interface (SCSI). 3: Serial Attached SCSI (SAS). 4: Serial Advanced Technology Attachment (SATA). 5: Fibre channel. 6: PCIe.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSpareState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.22 | INTEGER | RO | mandatory | notASpare(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory The status of the disk as a spare. Possible values: 1: Physical disk is not a spare. 2: Physical disk is a dedicated hot spare. 3: Physical disk is a global hot spare.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.24 | ObjectStatusEnum | RO | mandatory | 3 | ||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPartNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.27 | DisplayString | RO | mandatory | PH001M0DTB20093M6N50A00 | ||||||||||||||||
column · DisplayString · read-only · mandatory The part number of the disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSASAddress | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.28 | DisplayString | RO | mandatory | 0x500003994872E56A | ||||||||||||||||
column · DisplayString · read-only · mandatory The SAS address of the physical disk. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskNegotiatedSpeed | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.29 | INTEGER | RO | mandatory | sixGbps(4) | ||||||||||||||||
column · INTEGER · read-only · mandatory The data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps 6: 5 GT/s (applicable for NVMe devices). 7: 8 GT/s (applicable for NVMe devices).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskCapableSpeed | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.30 | INTEGER | RO | mandatory | twelveGbps(5) | ||||||||||||||||
column · INTEGER · read-only · mandatory The maximum data transfer speed supported by the disk in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5: 12.0 Gbps 6: 5 GT/s (applicable for NVMe devices). 7: 8 GT/s (applicable for NVMe devices).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSmartAlertIndication | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.31 | BooleanType | RO | mandatory | 0 | ||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether the physical disk has received a predictive failure alert. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufactureDay | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.32 | DisplayString | RO | mandatory | 6 | ||||||||||||||||
column · DisplayString · read-only · mandatory The day of the week (1=Sunday thru 7=Saturday) on which the physical disk was manufactured. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufactureWeek | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.33 | DisplayString | RO | mandatory | 12 | ||||||||||||||||
column · DisplayString · read-only · mandatory The week (1 thru 53) in which the physical disk was manufactured. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskManufactureYear | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.34 | DisplayString | RO | mandatory | 2019 | ||||||||||||||||
column · DisplayString · read-only · mandatory The four digit year in which the physical disk was manufactured. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskMediaType | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.35 | INTEGER | RO | mandatory | hdd(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Device (SSD).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPowerState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.42 | INTEGER | RO | mandatory | spunUp(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory The power state of the physical disk. Possible Values: 1: Not one of the following. 2: The physical disk is in the spun up state. 3: The physical disk is in the spun down state. 4: The physical disk is changing from spun down state to spun up state or vice versa. 5: The Solid State Device (SSD) is powered on.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskRemainingRatedWriteEndurance | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.49 | INTEGER (0..255) | RO | mandatory | 255 | ||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory This property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if the value is not available or not applicable (in the case of HDD media type) the value will be 255. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskOperationalState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.50 | INTEGER | RO | mandatory | notApplicable(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory The state of the physical disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: Data from a redundant virtual disk is currently being rebuilt onto the physical disk. 3: Data on the disk is being erased. 4: Data is being copied from a hot spare disk to the physical disk or vice versa.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskProgress | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.51 | INTEGER (0..100) | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The progress percentage of the operation that is being performed on the physical disk. This is applicable only if there is a progressive operations ongoing Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskSecurityStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.52 | INTEGER | RO | mandatory | notSupported(2) | ||||||||||||||||
column · INTEGER · read-only · mandatory The security/encryption status of the physical disk. Possible Values: 1: The physical disk supports encryption. 2: The physical disk does not support encryption 3: The physical disk is encrypted. 4: The physical disk is locked by a key. 5: The physical disk is locked by a foreign key.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskFormFactor | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.53 | INTEGER | RO | mandatory | twoDotFive(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory The form factor of the physical disk. Possible values: 1: The form factor could not be determined. 2: 1.8 inch. 3: 2.5 inch. 4: 3.5 inch.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.54 | FQDDString | RO | mandatory | Disk.Bay.4:Enclosure.Internal.0-0:RAID.ChassisI… | ||||||||||||||||
column · FQDDString · read-only · mandatory The physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.55 | DisplayString | RO | mandatory | Disk 4 in Backplane 0 of Chassis Integrated RAI… | ||||||||||||||||
column · DisplayString · read-only · mandatory The physical disk's friendly FQDD as represented in Storage Management. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskT10PICapability | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.57 | INTEGER | RO | mandatory | notCapable(3) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Capable of supporting T10 PI. 3: Not capable of supporting T10 PI.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskBlockSizeInBytes | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.58 | INTEGER | RO | mandatory | 512 | ||||||||||||||||
column · INTEGER · read-only · mandatory The block size (in bytes) of the physical disk. This is not applicable for NVMe devices. Possible values: 1: 512. 2: 4096 Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskProtocolVersion | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.59 | DisplayString | RO | mandatory | Not Applicable | ||||||||||||||||
column · DisplayString · read-only · mandatory Applicable for NVMe devices only. The NVMe protocol version supported by the device. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPCIeNegotiatedLinkWidth | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.60 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Applicable for NVMe devices only. The PCIe link width negotiated with the host during device initialization.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskPCIeCapableLinkWidth | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.61 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Applicable for NVMe devices only. The PCIe link widths the device is capable of supporting.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskCurrentActiveController | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.62 | FQDDString | RO | mandatory | Not Applicable | ||||||||||||||||
column · FQDDString · read-only · mandatory Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskFailoverController | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.63 | FQDDString | RO | mandatory | Not Applicable | ||||||||||||||||
column · FQDDString · read-only · mandatory Indicates the Fully Qualified Device Descriptor (FQDD) of the failover controller. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CphysicalDiskForeignKeyIdentifier | 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.64 | DisplayString | RO | mandatory | Not Applicable | ||||||||||||||||
column · DisplayString · read-only · mandatory Displays the encryption key identifier of the physical disk if it is in locked or foreign state. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TenclosureFanTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed fans in the external storage enclosure(s). The number of entries is related to number of fans discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureFanTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the fan table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CenclosureFanNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Instance number of this fan. | |||||||||||||||||||||
| CenclosureFanName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The fan's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureFanState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current state of this fan. Possible states: 1: The current state could not be determined. 2: The fan is operating normally. 3: The fan has encountered a hardware problem or is not responding. 4: The fan is no longer connected to the enclosure or there exists a problem communicating to it. 5: The fan is unstable.
| |||||||||||||||||||||
| CenclosureFanSpeed | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the current relative speed of the fan in RPMs. | |||||||||||||||||||||
| CenclosureFanComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.15 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureFanFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.20 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory The fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureFanDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.7.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The fan's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TenclosurePowerSupplyTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed Power Supply Units(PSU) in the external storage enclosure(s). The number of entries is related to number of power supply unit(s) discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosurePowerSupplyTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the power supply unit table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. | |||||||||||||||||||||
| CenclosurePowerSupplyNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Instance number of this power supply unit. | |||||||||||||||||||||
| CenclosurePowerSupplyName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The power supply unit's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosurePowerSupplyState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current state of this power supply unit. Possible states: 1: The current state could not be determined. 2: The power supply unit is operating normally. 3: The power supply unit has encountered a hardware problem or is not responding. 4: The power supply unit is no longer connected to the enclosure or there exists a problem communicating to it. 5: The power supply unit is unstable.
| |||||||||||||||||||||
| CenclosurePowerSupplyPartNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The part number of the power supply unit. | |||||||||||||||||||||
| CenclosurePowerSupplyComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.9 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosurePowerSupplyFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.15 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory The power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosurePowerSupplyDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.9.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The power supply unit's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TenclosureTemperatureProbeTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed temperature probes in the external storage enclosure(s). The number of entries is related to number of temperature probes discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureTemperatureProbeTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the temperature probe table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. | |||||||||||||||||||||
| CenclosureTemperatureProbeNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Instance number of this temperature probe. | |||||||||||||||||||||
| CenclosureTemperatureProbeName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The temperature probe's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureTemperatureProbeState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current state of this temperature probe. Possible states: 1: The current state could not be determined. 2: The temperature probe is operating normally. 3: The temperature probe has encountered a hardware problem or is not responding. 4: The temperature probe is no longer connected to the enclosure or there exists a problem communicating to it. 5: The temperature probe is unstable. 6: The temperature probe is Over Warning Temperature. 7: The temperature probe is Under Warning Temperature.
| |||||||||||||||||||||
| CenclosureTemperatureProbeMinWarningValue | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The minimum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeMinCriticalValue | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The minimum temperature that will force the probe into a error state. | |||||||||||||||||||||
| CenclosureTemperatureProbeMaxWarningValue | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The maximum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeMaxCriticalValue | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The maximum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeCurValue | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The maximum temperature that will force the probe into a warning state. | |||||||||||||||||||||
| CenclosureTemperatureProbeComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.13 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureTemperatureProbeFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.15 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory The temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureTemperatureProbeDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.11.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The temperature probe's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TenclosureManagementModuleTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed Enclosure Management Modules (EMM) in the external storage enclosure(s). The number of entries is related to number of enclosure management modules discovered in the enclosure(s). The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RenclosureManagementModuleTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the enclosure management module table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. | |||||||||||||||||||||
| CenclosureManagementModuleNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Instance number of this enclosure management module. | |||||||||||||||||||||
| CenclosureManagementModuleName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The enclosure management module's name as represented in Storage Management. | |||||||||||||||||||||
| CenclosureManagementModuleState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current state of this enclosure management module. Possible states: 1: The current state could not be determined. 2: The enclosure management module is operating normally. 3: The enclosure management module has encountered a hardware problem or is not responding. 4: The enclosure management module is no longer connected to the enclosure or there exists a problem communicating to it. 5: The enclosure management module is unstable.
| |||||||||||||||||||||
| CenclosureManagementModulePartNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The part number of the enclosure management module. | |||||||||||||||||||||
| CenclosureManagementModuleFWVersion | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Firmware version of the enclosure management module. | |||||||||||||||||||||
| CenclosureManagementModuleComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.11 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CenclosureManagementModuleFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.15 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory The enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CenclosureManagementModuleDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.16 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The enclosure management module's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| TbatteryTable | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed batteries. The number of entries is related to number of Batteries discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RbatteryTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the battery table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CbatteryNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.1 | INTEGER (0..255) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..255) · read-only · mandatory Instance number of this battery entry. | |||||||||||||||||||||
| CbatteryState | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold.
| |||||||||||||||||||||
| CbatteryComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.6 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable | |||||||||||||||||||||
| CbatteryPredictedCapacity | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.10 | INTEGER | RO | obsolete | |||||||||||||||||
column · INTEGER · read-only · obsolete This entry is obsolete. Use the batteryComponentStatus or batteryState instead.
| |||||||||||||||||||||
| CbatteryFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.20 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CbatteryDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.130.15.1.21 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The battery's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| NlogicalDevices | 1.3.6.1.4.1.674.10892.2.6.1.20.140 | ||||||||||||||||||||
| TvirtualDiskTable | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of managed virtual disks. The number of entries is related to number of virtual disks discovered in the system. The maximum number of entries is implementation dependent. Note: The properties in this table may not be applicable to all entries. | |||||||||||||||||||||
| RvirtualDiskTableEntry | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry in the virtual disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
| |||||||||||||||||||||
| CvirtualDiskNumber | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.1 | INTEGER (0..100000000) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100000000) · read-only · mandatory Instance number of this virtual disk entry. | |||||||||||||||||||||
| CvirtualDiskName | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The virtual disk's label as entered by the user. | |||||||||||||||||||||
| CvirtualDiskState | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4: The virtual disk encounterd a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant.
| |||||||||||||||||||||
| CvirtualDiskSizeInMB | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The size of the virtual disk in megabytes. | |||||||||||||||||||||
| CvirtualDiskWritePolicy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back.
| |||||||||||||||||||||
| CvirtualDiskReadPolicy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead.
| |||||||||||||||||||||
| CvirtualDiskLayout | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5
| |||||||||||||||||||||
| CvirtualDiskStripeSize | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The stripe size of this virtual disk. Possible values: 1: Not one of the following 2: Default. 3: 512 bytes 4: 1 kB, 5: 2 kB, 6: 4 kB, 7: 8 kB, 8: 16 kB, 9: 32 kB, 10: 64 kB, 11: 128 kB, 12: 256 kB, 13: 512 kB, 14: 1 MB, 15: 2 MB, 16: 4 MB, 17: 8 MB, 18: 16 MB
| |||||||||||||||||||||
| CvirtualDiskComponentStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.20 | ObjectStatusEnum | RO | mandatory | |||||||||||||||||
column · ObjectStatusEnum · read-only · mandatory The status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Critical. 6: Non-recoverable. | |||||||||||||||||||||
| CvirtualDiskBadBlocksDetected | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.23 | BooleanType | RO | mandatory | |||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether the virtual disk has bad blocks. | |||||||||||||||||||||
| CvirtualDiskSecured | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.24 | BooleanType | RO | mandatory | |||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether the virtual disk is secured or not. | |||||||||||||||||||||
| CvirtualDiskIsCacheCade | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.25 | BooleanType | RO | mandatory | |||||||||||||||||
column · BooleanType · read-only · mandatory Indicates whether the virtual disk is being used as a secondary cache by the controller. | |||||||||||||||||||||
| CvirtualDiskDiskCachePolicy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.26 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The cache policy of the physical disks that are part of this virtual disk Possible values: 1: Enabled. 2: Disabled. 3: Default.
| |||||||||||||||||||||
| CvirtualDiskOperationalState | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.30 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk.
| |||||||||||||||||||||
| CvirtualDiskProgress | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.31 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The progress percentage of the operation that is being performed on the virtual disk. This is applicable only if there is a progressive operations ongoing | |||||||||||||||||||||
| CvirtualDiskAvailableProtocols | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.32 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory List of protocols support by physical disks part of this virtual disk. For e.g. SAS for Serial Attached SCSI or SATA for Serial Advanced Technology Attachment. | |||||||||||||||||||||
| CvirtualDiskMediaType | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.33 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory List of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device. | |||||||||||||||||||||
| CvirtualDiskRemainingRedundancy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.34 | INTEGER (0..2) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..2) · read-only · mandatory The number of physical disks which can be lost before the virtual disk loses its redundancy. | |||||||||||||||||||||
| CvirtualDiskFQDD | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.35 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory The virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. | |||||||||||||||||||||
| CvirtualDiskDisplayName | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.36 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The virtual disk's friendly FQDD as represented in Storage Management. | |||||||||||||||||||||
| CvirtualDiskT10PIStatus | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.37 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether the virtual disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1: Not one of the following. 2: Enabled. 3: Disabled.
| |||||||||||||||||||||
| CvirtualDiskBlockSizeInBytes | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.38 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1: 512. 2: 4096 | |||||||||||||||||||||
| CvirtualDiskAdapter1AccessPolicy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.39 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
| |||||||||||||||||||||
| CvirtualDiskAdapter2AccessPolicy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.40 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
| |||||||||||||||||||||
| CvirtualDiskAdapter3AccessPolicy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.41 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
| |||||||||||||||||||||
| CvirtualDiskAdapter4AccessPolicy | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.42 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the access policy of the virtual disk with the virtual adapters. Possible values: 1: No Access. 2: Full Access
| |||||||||||||||||||||
| CvirtualDiskCurrentActiveController | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.43 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. | |||||||||||||||||||||
| CvirtualDiskFailoverController | 1.3.6.1.4.1.674.10892.2.6.1.20.140.1.1.44 | FQDDString | RO | mandatory | |||||||||||||||||
column · FQDDString · read-only · mandatory Indicates the Fully Qualified Device Descriptor (FQDD) of the failover controller. | |||||||||||||||||||||
| NdrsCMCAlertGroup | 1.3.6.1.4.1.674.10892.2.20 | ||||||||||||||||||||
| NdrsChassisAlertVariables | 1.3.6.1.4.1.674.10892.2.20.10 | ||||||||||||||||||||
| SdrsCASubSystem | 1.3.6.1.4.1.674.10892.2.20.10.1 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert | |||||||||||||||||||||
| SdrsCASSCurrStatus | 1.3.6.1.4.1.674.10892.2.20.10.2 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System | |||||||||||||||||||||
| SdrsCASSPrevStatus | 1.3.6.1.4.1.674.10892.2.20.10.3 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System | |||||||||||||||||||||
| SdrsCASSChangeTime | 1.3.6.1.4.1.674.10892.2.20.10.4 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory 0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System | |||||||||||||||||||||
| SdrsCAMessage | 1.3.6.1.4.1.674.10892.2.20.10.5 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory 0020.0010.0005 This attribute defines the CSSD message of the CMC Alert | |||||||||||||||||||||
| NdrsCMCAlert2Group | 1.3.6.1.4.1.674.10892.2.21 | ||||||||||||||||||||
| !alert2FanFailure | 1.3.6.1.4.1.674.10892.2.21.0.2153 | ||||||||||||||||||||
notification Fan failure. | |||||||||||||||||||||
| !alert2FanWarning | 1.3.6.1.4.1.674.10892.2.21.0.2154 | ||||||||||||||||||||
notification Fan warning. | |||||||||||||||||||||
| !alert2FanInformation | 1.3.6.1.4.1.674.10892.2.21.0.2155 | ||||||||||||||||||||
notification Fan information. | |||||||||||||||||||||
| !alert2TemperatureProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.2161 | ||||||||||||||||||||
notification Temperature sensor has detected a failure value. | |||||||||||||||||||||
| !alert2TemperatureProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.2162 | ||||||||||||||||||||
notification Temperature sensor has detected a warning value. | |||||||||||||||||||||
| !alert2TemperatureProbeNormal | 1.3.6.1.4.1.674.10892.2.21.0.2163 | ||||||||||||||||||||
notification Temperature sensor value is within range. | |||||||||||||||||||||
| !alert2VoltageProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.2169 | ||||||||||||||||||||
notification Voltage sensor has detected a failure value. | |||||||||||||||||||||
| !alert2VoltageProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.2170 | ||||||||||||||||||||
notification Voltage sensor has detected a warning value. | |||||||||||||||||||||
| !alert2VoltageProbeNormal | 1.3.6.1.4.1.674.10892.2.21.0.2171 | ||||||||||||||||||||
notification Voltage sensor reading is within range. | |||||||||||||||||||||
| !alert2AmperageProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.2177 | ||||||||||||||||||||
notification Current sensor has detected a failure value. | |||||||||||||||||||||
| !alert2AmperageProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.2178 | ||||||||||||||||||||
notification Current sensor has detected a warning value. | |||||||||||||||||||||
| !alert2AmperageProbeNormal | 1.3.6.1.4.1.674.10892.2.21.0.2179 | ||||||||||||||||||||
notification Current sensor reading is within range. | |||||||||||||||||||||
| !alert2PowerSupplyFailure | 1.3.6.1.4.1.674.10892.2.21.0.2185 | ||||||||||||||||||||
notification Power supply has detected a failure. | |||||||||||||||||||||
| !alert2PowerSupplyWarning | 1.3.6.1.4.1.674.10892.2.21.0.2186 | ||||||||||||||||||||
notification Power supply has detected a warning. | |||||||||||||||||||||
| !alert2PowerSupplyNormal | 1.3.6.1.4.1.674.10892.2.21.0.2187 | ||||||||||||||||||||
notification Power supply has returned to normal. | |||||||||||||||||||||
| !alert2BatteryFailure | 1.3.6.1.4.1.674.10892.2.21.0.2225 | ||||||||||||||||||||
notification Battery has failed or battery is absent. | |||||||||||||||||||||
| !alert2BatteryWarning | 1.3.6.1.4.1.674.10892.2.21.0.2226 | ||||||||||||||||||||
notification Battery is low. | |||||||||||||||||||||
| !alert2BatteryNormal | 1.3.6.1.4.1.674.10892.2.21.0.2227 | ||||||||||||||||||||
notification Battery state has returned to normal; or battery presence had been detected. | |||||||||||||||||||||
| !alert2LinkStatusFailure | 1.3.6.1.4.1.674.10892.2.21.0.2249 | ||||||||||||||||||||
notification Link status failure or critical event. | |||||||||||||||||||||
| !alert2LinkStatusWarning | 1.3.6.1.4.1.674.10892.2.21.0.2250 | ||||||||||||||||||||
notification Link status warning. | |||||||||||||||||||||
| !alert2LinkStatusInformation | 1.3.6.1.4.1.674.10892.2.21.0.2251 | ||||||||||||||||||||
notification Link status information. | |||||||||||||||||||||
| !alert2PowerUsageFailure | 1.3.6.1.4.1.674.10892.2.21.0.2273 | ||||||||||||||||||||
notification Power usage failure. | |||||||||||||||||||||
| !alert2PowerUsageWarning | 1.3.6.1.4.1.674.10892.2.21.0.2274 | ||||||||||||||||||||
notification Power usage warning. | |||||||||||||||||||||
| !alert2PowerUsageInformation | 1.3.6.1.4.1.674.10892.2.21.0.2275 | ||||||||||||||||||||
notification Power usage information. | |||||||||||||||||||||
| !alert2HardwareConfigurationFailure | 1.3.6.1.4.1.674.10892.2.21.0.2329 | ||||||||||||||||||||
notification Hardware configuration failure or critical event. | |||||||||||||||||||||
| !alert2HardwareConfigurationWarning | 1.3.6.1.4.1.674.10892.2.21.0.2330 | ||||||||||||||||||||
notification Hardware configuration warning. | |||||||||||||||||||||
| !alert2HardwareConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.2331 | ||||||||||||||||||||
notification Hardware configuration information. | |||||||||||||||||||||
| !alert2SoftwareConfigurationFailure | 1.3.6.1.4.1.674.10892.2.21.0.2337 | ||||||||||||||||||||
notification Software configuration failure. | |||||||||||||||||||||
| !alert2SoftwareConfigurationWarning | 1.3.6.1.4.1.674.10892.2.21.0.2338 | ||||||||||||||||||||
notification Software configuration warning. | |||||||||||||||||||||
| !alert2SoftwareConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.2339 | ||||||||||||||||||||
notification Software configuration information. | |||||||||||||||||||||
| !alert2SystemEventLogFailure | 1.3.6.1.4.1.674.10892.2.21.0.2377 | ||||||||||||||||||||
notification System Event Log failure or critical event. | |||||||||||||||||||||
| !alert2SystemEventLogWarning | 1.3.6.1.4.1.674.10892.2.21.0.2378 | ||||||||||||||||||||
notification System Event Log warning. | |||||||||||||||||||||
| !alert2SystemEventLogInformation | 1.3.6.1.4.1.674.10892.2.21.0.2379 | ||||||||||||||||||||
notification System Event Log information. | |||||||||||||||||||||
| !alert2SecurityFailure | 1.3.6.1.4.1.674.10892.2.21.0.2385 | ||||||||||||||||||||
notification Security failure or critical event. | |||||||||||||||||||||
| !alert2SecurityWarning | 1.3.6.1.4.1.674.10892.2.21.0.2386 | ||||||||||||||||||||
notification Security warning. | |||||||||||||||||||||
| !alert2SecurityInformation | 1.3.6.1.4.1.674.10892.2.21.0.2387 | ||||||||||||||||||||
notification Security information. | |||||||||||||||||||||
| !alert2CableFailure | 1.3.6.1.4.1.674.10892.2.21.0.2393 | ||||||||||||||||||||
notification Cable failure. | |||||||||||||||||||||
| !alert2PCIDeviceFailure | 1.3.6.1.4.1.674.10892.2.21.0.2417 | ||||||||||||||||||||
notification PCI device failure or critical event. | |||||||||||||||||||||
| !alert2PCIDeviceWarning | 1.3.6.1.4.1.674.10892.2.21.0.2418 | ||||||||||||||||||||
notification PCI device warning. | |||||||||||||||||||||
| !alert2PCIDeviceInformation | 1.3.6.1.4.1.674.10892.2.21.0.2419 | ||||||||||||||||||||
notification PCI device information. | |||||||||||||||||||||
| !alert2PowerSupplyAbsent | 1.3.6.1.4.1.674.10892.2.21.0.2465 | ||||||||||||||||||||
notification Power supply is absent. | |||||||||||||||||||||
| !alert2RedundancyLost | 1.3.6.1.4.1.674.10892.2.21.0.2473 | ||||||||||||||||||||
notification Redundancy is lost. | |||||||||||||||||||||
| !alert2RedundancyDegraded | 1.3.6.1.4.1.674.10892.2.21.0.2474 | ||||||||||||||||||||
notification Redundancy is degraded. | |||||||||||||||||||||
| !alert2RedundancyInformation | 1.3.6.1.4.1.674.10892.2.21.0.2475 | ||||||||||||||||||||
notification Redundancy information. | |||||||||||||||||||||
| !alert2CMCFailure | 1.3.6.1.4.1.674.10892.2.21.0.2545 | ||||||||||||||||||||
notification Chassis Management Controller detected an error. | |||||||||||||||||||||
| !alert2CMCWarning | 1.3.6.1.4.1.674.10892.2.21.0.2546 | ||||||||||||||||||||
notification Chassis Management Controller detected a warning. | |||||||||||||||||||||
| !alert2IOVirtualizationFailure | 1.3.6.1.4.1.674.10892.2.21.0.2553 | ||||||||||||||||||||
notification IO Virtualization failure or critical event. | |||||||||||||||||||||
| !alert2IOVirtualizationWarning | 1.3.6.1.4.1.674.10892.2.21.0.2554 | ||||||||||||||||||||
notification IO Virtualization warning. | |||||||||||||||||||||
| !alert2IOVirtualizationInformation | 1.3.6.1.4.1.674.10892.2.21.0.2555 | ||||||||||||||||||||
notification IO Virtualization information. | |||||||||||||||||||||
| !alert2StorageManagementFailure | 1.3.6.1.4.1.674.10892.2.21.0.4177 | ||||||||||||||||||||
notification Storage Management has detected a device independent error condition. There is no global status change associated with this trap. | |||||||||||||||||||||
| !alert2StorageManagementWarning | 1.3.6.1.4.1.674.10892.2.21.0.4178 | ||||||||||||||||||||
notification Storage Management has detected a device independent warning condition. There is no global status change associated with this trap. | |||||||||||||||||||||
| !alert2StorageManagementInformation | 1.3.6.1.4.1.674.10892.2.21.0.4179 | ||||||||||||||||||||
notification Storage Management information. There is no global status change associated with this trap. | |||||||||||||||||||||
| !alert2StorageFanFailure | 1.3.6.1.4.1.674.10892.2.21.0.4201 | ||||||||||||||||||||
notification Storage Fan failure. | |||||||||||||||||||||
| !alert2StorageFanWarning | 1.3.6.1.4.1.674.10892.2.21.0.4202 | ||||||||||||||||||||
notification Storage Fan warning. | |||||||||||||||||||||
| !alert2StorageFanInformation | 1.3.6.1.4.1.674.10892.2.21.0.4203 | ||||||||||||||||||||
notification Storage Fan information. | |||||||||||||||||||||
| !alert2StorageTemperatureProbeFailure | 1.3.6.1.4.1.674.10892.2.21.0.4209 | ||||||||||||||||||||
notification Storage Temperature probe failure. | |||||||||||||||||||||
| !alert2StorageTemperatureProbeWarning | 1.3.6.1.4.1.674.10892.2.21.0.4210 | ||||||||||||||||||||
notification Storage Temperature probe warning. | |||||||||||||||||||||
| !alert2StorageTemperatureProbeInformation | 1.3.6.1.4.1.674.10892.2.21.0.4211 | ||||||||||||||||||||
notification Storage Temperature probe information. | |||||||||||||||||||||
| !alert2StoragePowerSupplyFailure | 1.3.6.1.4.1.674.10892.2.21.0.4233 | ||||||||||||||||||||
notification Storage Power supply failure. | |||||||||||||||||||||
| !alert2StoragePowerSupplyWarning | 1.3.6.1.4.1.674.10892.2.21.0.4234 | ||||||||||||||||||||
notification Storage Power supply warning. | |||||||||||||||||||||
| !alert2StoragePowerSupplyInformation | 1.3.6.1.4.1.674.10892.2.21.0.4235 | ||||||||||||||||||||
notification Storage Power supply information. | |||||||||||||||||||||
| !alert2StorageBatteryFailure | 1.3.6.1.4.1.674.10892.2.21.0.4273 | ||||||||||||||||||||
notification Storage Battery failure. | |||||||||||||||||||||
| !alert2StorageBatteryWarning | 1.3.6.1.4.1.674.10892.2.21.0.4274 | ||||||||||||||||||||
notification Storage Battery warning. | |||||||||||||||||||||
| !alert2StorageBatteryInformation | 1.3.6.1.4.1.674.10892.2.21.0.4275 | ||||||||||||||||||||
notification Storage Battery information. | |||||||||||||||||||||
| !alert2StorageControllerFailure | 1.3.6.1.4.1.674.10892.2.21.0.4329 | ||||||||||||||||||||
notification Storage Controller failure. | |||||||||||||||||||||
| !alert2StorageControllerWarning | 1.3.6.1.4.1.674.10892.2.21.0.4330 | ||||||||||||||||||||
notification Storage Controller warning. | |||||||||||||||||||||
| !alert2StorageControllerInformation | 1.3.6.1.4.1.674.10892.2.21.0.4331 | ||||||||||||||||||||
notification Storage Controller information. | |||||||||||||||||||||
| !alert2StorageEnclosureFailure | 1.3.6.1.4.1.674.10892.2.21.0.4337 | ||||||||||||||||||||
notification Storage Enclosure failure. | |||||||||||||||||||||
| !alert2StorageEnclosureWarning | 1.3.6.1.4.1.674.10892.2.21.0.4338 | ||||||||||||||||||||
notification Storage Enclosure warning. | |||||||||||||||||||||
| !alert2StorageEnclosureInformation | 1.3.6.1.4.1.674.10892.2.21.0.4339 | ||||||||||||||||||||
notification Storage Enclosure information. | |||||||||||||||||||||
| !alert2StoragePhysicalDiskFailure | 1.3.6.1.4.1.674.10892.2.21.0.4345 | ||||||||||||||||||||
notification Storage Physical disk failure. | |||||||||||||||||||||
| !alert2StoragePhysicalDiskWarning | 1.3.6.1.4.1.674.10892.2.21.0.4346 | ||||||||||||||||||||
notification Storage Physical disk warning. | |||||||||||||||||||||
| !alert2StoragePhysicalDiskInformation | 1.3.6.1.4.1.674.10892.2.21.0.4347 | ||||||||||||||||||||
notification Storage Physical disk information. | |||||||||||||||||||||
| !alert2StorageVirtualDiskFailure | 1.3.6.1.4.1.674.10892.2.21.0.4353 | ||||||||||||||||||||
notification Storage Virtual disk failure. | |||||||||||||||||||||
| !alert2StorageVirtualDiskWarning | 1.3.6.1.4.1.674.10892.2.21.0.4354 | ||||||||||||||||||||
notification Storage Virtual disk warning. | |||||||||||||||||||||
| !alert2StorageVirtualDiskInformation | 1.3.6.1.4.1.674.10892.2.21.0.4355 | ||||||||||||||||||||
notification Storage Virtual disk information. | |||||||||||||||||||||
| !alert2StorageSecurityFailure | 1.3.6.1.4.1.674.10892.2.21.0.4433 | ||||||||||||||||||||
notification Storage Security failure or critical event. | |||||||||||||||||||||
| !alert2StorageSecurityWarning | 1.3.6.1.4.1.674.10892.2.21.0.4434 | ||||||||||||||||||||
notification Storage Security warning. | |||||||||||||||||||||
| !alert2StorageSecurityInformation | 1.3.6.1.4.1.674.10892.2.21.0.4435 | ||||||||||||||||||||
notification Storage Security information. | |||||||||||||||||||||
| !alert2SoftwareChangeUpdateWarning | 1.3.6.1.4.1.674.10892.2.21.0.6314 | ||||||||||||||||||||
notification Software change update warning. | |||||||||||||||||||||
| !alert2IOMTemperatureExceeded | 1.3.6.1.4.1.674.10892.2.21.0.8305 | ||||||||||||||||||||
notification I/O Module <iom slot name> temperature exceeded operating range. | |||||||||||||||||||||
| !alert2Unable2ReadTemperatureSensors | 1.3.6.1.4.1.674.10892.2.21.0.8306 | ||||||||||||||||||||
notification Unable to read planar board temperature sensors. The cooling has been increased to safeguard the system. | |||||||||||||||||||||
| !alert2PowerSupplyAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8329 | ||||||||||||||||||||
notification Power Supply audit failure or critical event. | |||||||||||||||||||||
| !alert2PowerSupplyAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8330 | ||||||||||||||||||||
notification Power Supply audit warning. | |||||||||||||||||||||
| !alert2PowerSupplyRedundancyPolicyChanged | 1.3.6.1.4.1.674.10892.2.21.0.8331 | ||||||||||||||||||||
notification PSU redundancy policy changed. | |||||||||||||||||||||
| !alert2SoftwareChangeAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8361 | ||||||||||||||||||||
notification Software change audit failure or critical event. | |||||||||||||||||||||
| !alert2PowerUsageAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8417 | ||||||||||||||||||||
notification Power usage audit failure or critical event. | |||||||||||||||||||||
| !alert2PowerUsageAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8418 | ||||||||||||||||||||
notification Power usage audit warning. | |||||||||||||||||||||
| !alert2PowerUsageAuditInformation | 1.3.6.1.4.1.674.10892.2.21.0.8419 | ||||||||||||||||||||
notification Power usage audit information. | |||||||||||||||||||||
| !alert2LicenseFailure | 1.3.6.1.4.1.674.10892.2.21.0.8513 | ||||||||||||||||||||
notification License failure. | |||||||||||||||||||||
| !alert2LicenseWarning | 1.3.6.1.4.1.674.10892.2.21.0.8514 | ||||||||||||||||||||
notification License warning. | |||||||||||||||||||||
| !alert2LicenseInformation | 1.3.6.1.4.1.674.10892.2.21.0.8515 | ||||||||||||||||||||
notification License information. | |||||||||||||||||||||
| !alert2PCIDeviceAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8562 | ||||||||||||||||||||
notification PCI device audit warning. | |||||||||||||||||||||
| !alert2CMCAuditFailure | 1.3.6.1.4.1.674.10892.2.21.0.8689 | ||||||||||||||||||||
notification Chassis Management Controller audit failure or critical event. | |||||||||||||||||||||
| !alert2CMCAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8690 | ||||||||||||||||||||
notification Chassis Management Controller audit warning. | |||||||||||||||||||||
| !alert2CMCAuditInformation | 1.3.6.1.4.1.674.10892.2.21.0.8691 | ||||||||||||||||||||
notification Chassis Management Controller audit information. | |||||||||||||||||||||
| !alert2IOVirtualizationAuditWarning | 1.3.6.1.4.1.674.10892.2.21.0.8698 | ||||||||||||||||||||
notification IO Virtualization audit warning. | |||||||||||||||||||||
| !alert2CMCTestTrap | 1.3.6.1.4.1.674.10892.2.21.0.10395 | ||||||||||||||||||||
notification Test trap generated by CMC in response to a user request. | |||||||||||||||||||||
| !alert2SWCConfigurationFailure | 1.3.6.1.4.1.674.10892.2.21.0.10529 | ||||||||||||||||||||
notification Software configuration failure. | |||||||||||||||||||||
| !alert2SWCConfigurationWarning | 1.3.6.1.4.1.674.10892.2.21.0.10530 | ||||||||||||||||||||
notification Software configuration warning. | |||||||||||||||||||||
| !alert2PCIDeviceConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.10611 | ||||||||||||||||||||
notification PCI device configuration information. | |||||||||||||||||||||
| !alert2IOVConfigurationWarning | 1.3.6.1.4.1.674.10892.2.21.0.10746 | ||||||||||||||||||||
notification IO Virtualization configuration warning. | |||||||||||||||||||||
| !alert2IOVConfigurationInformation | 1.3.6.1.4.1.674.10892.2.21.0.10747 | ||||||||||||||||||||
notification IO Virtualization configuration information. | |||||||||||||||||||||
| NdrsChassisAlert2Variables | 1.3.6.1.4.1.674.10892.2.21.10 | ||||||||||||||||||||
| SdrsCA2MessageID | 1.3.6.1.4.1.674.10892.2.21.10.1 | DisplayString (SIZE (0..8)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..8)) · read-only · mandatory Message ID of the alert. | |||||||||||||||||||||
| SdrsCA2Message | 1.3.6.1.4.1.674.10892.2.21.10.2 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory Message describing the alert. | |||||||||||||||||||||
| SdrsCA2MessageArgs | 1.3.6.1.4.1.674.10892.2.21.10.3 | DellString | RO | mandatory | |||||||||||||||||
scalar · DellString · read-only · mandatory Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes. | |||||||||||||||||||||
| SdrsCA2AlertStatus | 1.3.6.1.4.1.674.10892.2.21.10.4 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory Status of the alert. | |||||||||||||||||||||
| SdrsCA2FQDD | 1.3.6.1.4.1.674.10892.2.21.10.5 | DisplayString (SIZE (0..512)) | RO | mandatory | |||||||||||||||||
scalar · DisplayString (SIZE (0..512)) · read-only · mandatory Fully qualified device descriptor of device causing the alert. | |||||||||||||||||||||
| NdrsAlertGroup | 1.3.6.1.4.1.674.10892.2.5000 | ||||||||||||||||||||
| NdrsAlertVariables | 1.3.6.1.4.1.674.10892.2.5000.10 | ||||||||||||||||||||
| SdrsAlertSystem | 1.3.6.1.4.1.674.10892.2.5000.10.1 | OCTET STRING (SIZE (0..255)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..255)) · read-only · mandatory 5000.0010.0001 Name of the system generating the alert. | |||||||||||||||||||||
| SdrsAlertTableIndexOID | 1.3.6.1.4.1.674.10892.2.5000.10.2 | OBJECT IDENTIFIER | RO | mandatory | |||||||||||||||||
scalar · OBJECT IDENTIFIER · read-only · mandatory 5000.0010.0002 0.0 | |||||||||||||||||||||
| SdrsAlertMessage | 1.3.6.1.4.1.674.10892.2.5000.10.3 | OCTET STRING (SIZE (0..1024)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..1024)) · read-only · mandatory 5000.0010.0003 Message describing the alert. | |||||||||||||||||||||
| SdrsAlertCurrentStatus | 1.3.6.1.4.1.674.10892.2.5000.10.4 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 5000.0010.0004 Current status of object causing the alert. | |||||||||||||||||||||
| SdrsAlertPreviousStatus | 1.3.6.1.4.1.674.10892.2.5000.10.5 | DellStatus | RO | mandatory | |||||||||||||||||
scalar · DellStatus · read-only · mandatory 5000.0010.0005 Previous status of object causing the alert. | |||||||||||||||||||||
| SdrsAlertData | 1.3.6.1.4.1.674.10892.2.5000.10.6 | OCTET STRING (SIZE (0..1024)) | RO | mandatory | |||||||||||||||||
scalar · OCTET STRING (SIZE (0..1024)) · read-only · mandatory 5000.0010.0006 Alert data. | |||||||||||||||||||||
Traps / Notifications
- alert2AmperageProbeFailure
1.3.6.1.4.1.674.10892.2.21.0.2177 - alert2AmperageProbeNormal
1.3.6.1.4.1.674.10892.2.21.0.2179 - alert2AmperageProbeWarning
1.3.6.1.4.1.674.10892.2.21.0.2178 - alert2BatteryFailure
1.3.6.1.4.1.674.10892.2.21.0.2225 - alert2BatteryNormal
1.3.6.1.4.1.674.10892.2.21.0.2227 - alert2BatteryWarning
1.3.6.1.4.1.674.10892.2.21.0.2226 - alert2CMCAuditFailure
1.3.6.1.4.1.674.10892.2.21.0.8689 - alert2CMCAuditInformation
1.3.6.1.4.1.674.10892.2.21.0.8691 - alert2CMCAuditWarning
1.3.6.1.4.1.674.10892.2.21.0.8690 - alert2CMCFailure
1.3.6.1.4.1.674.10892.2.21.0.2545 - alert2CMCTestTrap
1.3.6.1.4.1.674.10892.2.21.0.10395 - alert2CMCWarning
1.3.6.1.4.1.674.10892.2.21.0.2546 - alert2CableFailure
1.3.6.1.4.1.674.10892.2.21.0.2393 - alert2FanFailure
1.3.6.1.4.1.674.10892.2.21.0.2153 - alert2FanInformation
1.3.6.1.4.1.674.10892.2.21.0.2155 - alert2FanWarning
1.3.6.1.4.1.674.10892.2.21.0.2154 - alert2HardwareConfigurationFailure
1.3.6.1.4.1.674.10892.2.21.0.2329 - alert2HardwareConfigurationInformation
1.3.6.1.4.1.674.10892.2.21.0.2331 - alert2HardwareConfigurationWarning
1.3.6.1.4.1.674.10892.2.21.0.2330 - alert2IOMTemperatureExceeded
1.3.6.1.4.1.674.10892.2.21.0.8305 - alert2IOVConfigurationInformation
1.3.6.1.4.1.674.10892.2.21.0.10747 - alert2IOVConfigurationWarning
1.3.6.1.4.1.674.10892.2.21.0.10746 - alert2IOVirtualizationAuditWarning
1.3.6.1.4.1.674.10892.2.21.0.8698 - alert2IOVirtualizationFailure
1.3.6.1.4.1.674.10892.2.21.0.2553 - alert2IOVirtualizationInformation
1.3.6.1.4.1.674.10892.2.21.0.2555 - alert2IOVirtualizationWarning
1.3.6.1.4.1.674.10892.2.21.0.2554 - alert2LicenseFailure
1.3.6.1.4.1.674.10892.2.21.0.8513 - alert2LicenseInformation
1.3.6.1.4.1.674.10892.2.21.0.8515 - alert2LicenseWarning
1.3.6.1.4.1.674.10892.2.21.0.8514 - alert2LinkStatusFailure
1.3.6.1.4.1.674.10892.2.21.0.2249 - alert2LinkStatusInformation
1.3.6.1.4.1.674.10892.2.21.0.2251 - alert2LinkStatusWarning
1.3.6.1.4.1.674.10892.2.21.0.2250 - alert2PCIDeviceAuditWarning
1.3.6.1.4.1.674.10892.2.21.0.8562 - alert2PCIDeviceConfigurationInformation
1.3.6.1.4.1.674.10892.2.21.0.10611 - alert2PCIDeviceFailure
1.3.6.1.4.1.674.10892.2.21.0.2417 - alert2PCIDeviceInformation
1.3.6.1.4.1.674.10892.2.21.0.2419 - alert2PCIDeviceWarning
1.3.6.1.4.1.674.10892.2.21.0.2418 - alert2PowerSupplyAbsent
1.3.6.1.4.1.674.10892.2.21.0.2465 - alert2PowerSupplyAuditFailure
1.3.6.1.4.1.674.10892.2.21.0.8329 - alert2PowerSupplyAuditWarning
1.3.6.1.4.1.674.10892.2.21.0.8330 - alert2PowerSupplyFailure
1.3.6.1.4.1.674.10892.2.21.0.2185 - alert2PowerSupplyNormal
1.3.6.1.4.1.674.10892.2.21.0.2187 - alert2PowerSupplyRedundancyPolicyChanged
1.3.6.1.4.1.674.10892.2.21.0.8331 - alert2PowerSupplyWarning
1.3.6.1.4.1.674.10892.2.21.0.2186 - alert2PowerUsageAuditFailure
1.3.6.1.4.1.674.10892.2.21.0.8417 - alert2PowerUsageAuditInformation
1.3.6.1.4.1.674.10892.2.21.0.8419 - alert2PowerUsageAuditWarning
1.3.6.1.4.1.674.10892.2.21.0.8418 - alert2PowerUsageFailure
1.3.6.1.4.1.674.10892.2.21.0.2273 - alert2PowerUsageInformation
1.3.6.1.4.1.674.10892.2.21.0.2275 - alert2PowerUsageWarning
1.3.6.1.4.1.674.10892.2.21.0.2274 - alert2RedundancyDegraded
1.3.6.1.4.1.674.10892.2.21.0.2474 - alert2RedundancyInformation
1.3.6.1.4.1.674.10892.2.21.0.2475 - alert2RedundancyLost
1.3.6.1.4.1.674.10892.2.21.0.2473 - alert2SWCConfigurationFailure
1.3.6.1.4.1.674.10892.2.21.0.10529 - alert2SWCConfigurationWarning
1.3.6.1.4.1.674.10892.2.21.0.10530 - alert2SecurityFailure
1.3.6.1.4.1.674.10892.2.21.0.2385 - alert2SecurityInformation
1.3.6.1.4.1.674.10892.2.21.0.2387 - alert2SecurityWarning
1.3.6.1.4.1.674.10892.2.21.0.2386 - alert2SoftwareChangeAuditFailure
1.3.6.1.4.1.674.10892.2.21.0.8361 - alert2SoftwareChangeUpdateWarning
1.3.6.1.4.1.674.10892.2.21.0.6314 - alert2SoftwareConfigurationFailure
1.3.6.1.4.1.674.10892.2.21.0.2337 - alert2SoftwareConfigurationInformation
1.3.6.1.4.1.674.10892.2.21.0.2339 - alert2SoftwareConfigurationWarning
1.3.6.1.4.1.674.10892.2.21.0.2338 - alert2StorageBatteryFailure
1.3.6.1.4.1.674.10892.2.21.0.4273 - alert2StorageBatteryInformation
1.3.6.1.4.1.674.10892.2.21.0.4275 - alert2StorageBatteryWarning
1.3.6.1.4.1.674.10892.2.21.0.4274 - alert2StorageControllerFailure
1.3.6.1.4.1.674.10892.2.21.0.4329 - alert2StorageControllerInformation
1.3.6.1.4.1.674.10892.2.21.0.4331 - alert2StorageControllerWarning
1.3.6.1.4.1.674.10892.2.21.0.4330 - alert2StorageEnclosureFailure
1.3.6.1.4.1.674.10892.2.21.0.4337 - alert2StorageEnclosureInformation
1.3.6.1.4.1.674.10892.2.21.0.4339 - alert2StorageEnclosureWarning
1.3.6.1.4.1.674.10892.2.21.0.4338 - alert2StorageFanFailure
1.3.6.1.4.1.674.10892.2.21.0.4201 - alert2StorageFanInformation
1.3.6.1.4.1.674.10892.2.21.0.4203 - alert2StorageFanWarning
1.3.6.1.4.1.674.10892.2.21.0.4202 - alert2StorageManagementFailure
1.3.6.1.4.1.674.10892.2.21.0.4177 - alert2StorageManagementInformation
1.3.6.1.4.1.674.10892.2.21.0.4179 - alert2StorageManagementWarning
1.3.6.1.4.1.674.10892.2.21.0.4178 - alert2StoragePhysicalDiskFailure
1.3.6.1.4.1.674.10892.2.21.0.4345 - alert2StoragePhysicalDiskInformation
1.3.6.1.4.1.674.10892.2.21.0.4347 - alert2StoragePhysicalDiskWarning
1.3.6.1.4.1.674.10892.2.21.0.4346 - alert2StoragePowerSupplyFailure
1.3.6.1.4.1.674.10892.2.21.0.4233 - alert2StoragePowerSupplyInformation
1.3.6.1.4.1.674.10892.2.21.0.4235 - alert2StoragePowerSupplyWarning
1.3.6.1.4.1.674.10892.2.21.0.4234 - alert2StorageSecurityFailure
1.3.6.1.4.1.674.10892.2.21.0.4433 - alert2StorageSecurityInformation
1.3.6.1.4.1.674.10892.2.21.0.4435 - alert2StorageSecurityWarning
1.3.6.1.4.1.674.10892.2.21.0.4434 - alert2StorageTemperatureProbeFailure
1.3.6.1.4.1.674.10892.2.21.0.4209 - alert2StorageTemperatureProbeInformation
1.3.6.1.4.1.674.10892.2.21.0.4211 - alert2StorageTemperatureProbeWarning
1.3.6.1.4.1.674.10892.2.21.0.4210 - alert2StorageVirtualDiskFailure
1.3.6.1.4.1.674.10892.2.21.0.4353 - alert2StorageVirtualDiskInformation
1.3.6.1.4.1.674.10892.2.21.0.4355 - alert2StorageVirtualDiskWarning
1.3.6.1.4.1.674.10892.2.21.0.4354 - alert2SystemEventLogFailure
1.3.6.1.4.1.674.10892.2.21.0.2377 - alert2SystemEventLogInformation
1.3.6.1.4.1.674.10892.2.21.0.2379 - alert2SystemEventLogWarning
1.3.6.1.4.1.674.10892.2.21.0.2378 - alert2TemperatureProbeFailure
1.3.6.1.4.1.674.10892.2.21.0.2161 - alert2TemperatureProbeNormal
1.3.6.1.4.1.674.10892.2.21.0.2163 - alert2TemperatureProbeWarning
1.3.6.1.4.1.674.10892.2.21.0.2162 - alert2Unable2ReadTemperatureSensors
1.3.6.1.4.1.674.10892.2.21.0.8306 - alert2VoltageProbeFailure
1.3.6.1.4.1.674.10892.2.21.0.2169 - alert2VoltageProbeNormal
1.3.6.1.4.1.674.10892.2.21.0.2171 - alert2VoltageProbeWarning
1.3.6.1.4.1.674.10892.2.21.0.2170 - alertCMCCriticalTrap
1.3.6.1.4.1.674.10892.2.0.2004 - alertCMCNonRecoverableTrap
1.3.6.1.4.1.674.10892.2.0.2005 - alertCMCNormalTrap
1.3.6.1.4.1.674.10892.2.0.2002 - alertCMCTestTrap
1.3.6.1.4.1.674.10892.2.0.2000 - alertCMCWarningTrap
1.3.6.1.4.1.674.10892.2.0.2003 - alertDrscAuthError
1.3.6.1.4.1.674.10892.2.0.1002 - alertDrscBattLow
1.3.6.1.4.1.674.10892.2.0.1008 - alertDrscFoundESM
1.3.6.1.4.1.674.10892.2.0.1004 - alertDrscLostESM
1.3.6.1.4.1.674.10892.2.0.1003 - alertDrscPowerOff
1.3.6.1.4.1.674.10892.2.0.1005 - alertDrscPowerOn
1.3.6.1.4.1.674.10892.2.0.1006 - alertDrscSEL100percentFull
1.3.6.1.4.1.674.10892.2.0.1019 - alertDrscSEL80percentFull
1.3.6.1.4.1.674.10892.2.0.1017 - alertDrscSEL90percentFull
1.3.6.1.4.1.674.10892.2.0.1018 - alertDrscSELCritical
1.3.6.1.4.1.674.10892.2.0.1016 - alertDrscSELNormal
1.3.6.1.4.1.674.10892.2.0.1020 - alertDrscSELWarning
1.3.6.1.4.1.674.10892.2.0.1015 - alertDrscTempCritical
1.3.6.1.4.1.674.10892.2.0.1011 - alertDrscTempNormal
1.3.6.1.4.1.674.10892.2.0.1009 - alertDrscTempWarning
1.3.6.1.4.1.674.10892.2.0.1010 - alertDrscTestTrapEvent
1.3.6.1.4.1.674.10892.2.0.1001 - alertDrscVoltCritical
1.3.6.1.4.1.674.10892.2.0.1014 - alertDrscVoltNormal
1.3.6.1.4.1.674.10892.2.0.1012 - alertDrscVoltWarning
1.3.6.1.4.1.674.10892.2.0.1013 - alertDrscWatchdogExpired
1.3.6.1.4.1.674.10892.2.0.1007