DELL-NETWORKING-CHASSIS-MIB
Force10 Networks, Inc.Dell Networking OS Chassis MIB.
snmptranslate -m DELL-NETWORKING-CHASSIS-MIB -Tpsnmpwalk -v2c -c <community> -m DELL-NETWORKING-CHASSIS-MIB <host> 1.3.6.1.4.1.6027.3.26Imports
| DELL-NETWORKING-SMI | dellNetMgmt |
|---|---|
| DELL-NETWORKING-TC | DellNetCardOperStatus, DellNetChassisType, DellNetDeviceType, DellNetHundredthdB, DellNetIfType, DellNetMfgDate, DellNetPEOperStatus, DellNetProcessorModuleType, DellNetSwDate, DellNetSystemCardType |
| IF-MIB | InterfaceIndex, ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, MacAddress, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IdellNetChassisMib | 1.3.6.1.4.1.6027.3.26 | ||||||||||||||||||||
identity Dell Networking OS Chassis MIB. | |||||||||||||||||||||
| NdellNetSysObject | 1.3.6.1.4.1.6027.3.26.1 | ||||||||||||||||||||
| NdellNetSysParameter | 1.3.6.1.4.1.6027.3.26.1.1 | ||||||||||||||||||||
| SdellNetDeviceType | 1.3.6.1.4.1.6027.3.26.1.1.1 | DellNetDeviceType | RO | ||||||||||||||||||
scalar · DellNetDeviceType · read-only · current The type of system the chassis falls under. | |||||||||||||||||||||
| NdellNetChassisObject | 1.3.6.1.4.1.6027.3.26.1.2 | ||||||||||||||||||||
| SdellNetNumChassis | 1.3.6.1.4.1.6027.3.26.1.2.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The total number of chassis configured on the cluster. | |||||||||||||||||||||
| SdellNetMaxNumChassis | 1.3.6.1.4.1.6027.3.26.1.2.2 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Indicates the maximum allowed chassis configurable on the cluster. | |||||||||||||||||||||
| TdellNetChassisTable | 1.3.6.1.4.1.6027.3.26.1.2.3 | NA | |||||||||||||||||||
table · not-accessible · current A list of chassis in a cluster. The chassis table contains the information of each chassis in the cluster. | |||||||||||||||||||||
| RdellNetChassisEntry | 1.3.6.1.4.1.6027.3.26.1.2.3.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of chassis entries containing information for the chassis.
| |||||||||||||||||||||
| CdellNetChassisIndex | 1.3.6.1.4.1.6027.3.26.1.2.3.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current A unique index for each chassis within the cluster. This value is the chassisId assigned to the chassis. | |||||||||||||||||||||
| CdellNetChassisType | 1.3.6.1.4.1.6027.3.26.1.2.3.1.2 | DellNetChassisType | RO | ||||||||||||||||||
column · DellNetChassisType · read-only · current The Dell Networking Model number of the chassis. | |||||||||||||||||||||
| CdellNetChassisMacAddr | 1.3.6.1.4.1.6027.3.26.1.2.3.1.3 | MacAddress | RO | ||||||||||||||||||
column · MacAddress · read-only · current A 6-octet MAC Address assigned to this Chassis. | |||||||||||||||||||||
| CdellNetChassisSerialNumber | 1.3.6.1.4.1.6027.3.26.1.2.3.1.4 | DisplayString (SIZE (0..14)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The chassis's serial number. | |||||||||||||||||||||
| CdellNetChassisPartNum | 1.3.6.1.4.1.6027.3.26.1.2.3.1.5 | DisplayString (SIZE (0..11)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..11)) · read-only · current The chassis manufacturer's part number. | |||||||||||||||||||||
| CdellNetChassisProductRev | 1.3.6.1.4.1.6027.3.26.1.2.3.1.6 | DisplayString (SIZE (0..3)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The chassis manufacturer's product revision. | |||||||||||||||||||||
| CdellNetChassisVendorId | 1.3.6.1.4.1.6027.3.26.1.2.3.1.7 | DisplayString (SIZE (0..3)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The chassis manufacturer vendor's id. | |||||||||||||||||||||
| CdellNetChassisMfgDate | 1.3.6.1.4.1.6027.3.26.1.2.3.1.8 | DellNetMfgDate | RO | ||||||||||||||||||
column · DellNetMfgDate · read-only · current The date the chassis was manufactured. | |||||||||||||||||||||
| CdellNetChassisCountryCode | 1.3.6.1.4.1.6027.3.26.1.2.3.1.9 | DisplayString (SIZE (0..2)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..2)) · read-only · current The chassis manufacturer's country code. | |||||||||||||||||||||
| CdellNetChassisPPIDRev | 1.3.6.1.4.1.6027.3.26.1.2.3.1.10 | DisplayString (SIZE (0..3)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The chassis's piece part ID revision. | |||||||||||||||||||||
| CdellNetChassisServiceTag | 1.3.6.1.4.1.6027.3.26.1.2.3.1.11 | DisplayString (SIZE (0..7)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The chassis's service tag. | |||||||||||||||||||||
| CdellNetChassisExpServiceCode | 1.3.6.1.4.1.6027.3.26.1.2.3.1.12 | DisplayString (SIZE (0..14)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The chassis's express service code. | |||||||||||||||||||||
| CdellNetChassisNumSlots | 1.3.6.1.4.1.6027.3.26.1.2.3.1.13 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of physical slots in the chassis. | |||||||||||||||||||||
| CdellNetChassisNumLineCardSlots | 1.3.6.1.4.1.6027.3.26.1.2.3.1.14 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of physical slots in the chassis for linecards. | |||||||||||||||||||||
| CdellNetChassisNumFanTrays | 1.3.6.1.4.1.6027.3.26.1.2.3.1.15 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of Fan trays in the chassis. | |||||||||||||||||||||
| CdellNetChassisNumPowerSupplies | 1.3.6.1.4.1.6027.3.26.1.2.3.1.16 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Number of Power supplies in the chassis. | |||||||||||||||||||||
| TdellNetCardTable | 1.3.6.1.4.1.6027.3.26.1.2.4 | NA | |||||||||||||||||||
table · not-accessible · current A list of line cards resident in the chassis. This table contains the information on each RPM and linecards in the chassis. | |||||||||||||||||||||
| RdellNetCardEntry | 1.3.6.1.4.1.6027.3.26.1.2.4.1 | NA | |||||||||||||||||||
row · not-accessible · current Entry for each card in the chassis. | |||||||||||||||||||||
| CdellNetCardIndex | 1.3.6.1.4.1.6027.3.26.1.2.4.1.1 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current A unique index for each card in the chassis. | |||||||||||||||||||||
| CdellNetCardType | 1.3.6.1.4.1.6027.3.26.1.2.4.1.2 | DellNetSystemCardType | RO | ||||||||||||||||||
column · DellNetSystemCardType · read-only · current Card's type. | |||||||||||||||||||||
| CdellNetCardDescription | 1.3.6.1.4.1.6027.3.26.1.2.4.1.3 | DisplayString (SIZE (0..40)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..40)) · read-only · current A short description of the card. | |||||||||||||||||||||
| CdellNetCardChassisIndex | 1.3.6.1.4.1.6027.3.26.1.2.4.1.4 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current A unique index for each card in the chassis across cluster This index will be derived from the dellNetChassisIndex and dellNetCardIndex.This index would act as dellNetProcessorDeviceIndex in dellNetProcessorTable, dellNetCpuUtilTable and dellNetSwModuleTable for deviceTypes linecard,rpm and supervisor | |||||||||||||||||||||
| CdellNetCardStatus | 1.3.6.1.4.1.6027.3.26.1.2.4.1.5 | DellNetCardOperStatus | RO | ||||||||||||||||||
column · DellNetCardOperStatus · read-only · current The current operational state of the card. | |||||||||||||||||||||
| CdellNetCardTemp | 1.3.6.1.4.1.6027.3.26.1.2.4.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Temperature of the card.
| |||||||||||||||||||||
| CdellNetCardVendorId | 1.3.6.1.4.1.6027.3.26.1.2.4.1.7 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The vendor id that manufactured this unit. | |||||||||||||||||||||
| CdellNetCardMfgDate | 1.3.6.1.4.1.6027.3.26.1.2.4.1.8 | DellNetMfgDate | RO | ||||||||||||||||||
column · DellNetMfgDate · read-only · current The date the unit is manufactured. | |||||||||||||||||||||
| CdellNetCardPartNum | 1.3.6.1.4.1.6027.3.26.1.2.4.1.9 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The unit part number | |||||||||||||||||||||
| CdellNetCardProductRev | 1.3.6.1.4.1.6027.3.26.1.2.4.1.10 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The unit manufacturer's product revision | |||||||||||||||||||||
| CdellNetCardProductOrder | 1.3.6.1.4.1.6027.3.26.1.2.4.1.11 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The product order number for this unit. | |||||||||||||||||||||
| CdellNetCardCountryCode | 1.3.6.1.4.1.6027.3.26.1.2.4.1.12 | OCTET STRING (SIZE (2)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (2)) · read-only · current The unit manufacturer's country code | |||||||||||||||||||||
| CdellNetCardPiecePartID | 1.3.6.1.4.1.6027.3.26.1.2.4.1.13 | DisplayString (SIZE (0..24)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..24)) · read-only · current The unit's piece part id. | |||||||||||||||||||||
| CdellNetCardPPIDRevision | 1.3.6.1.4.1.6027.3.26.1.2.4.1.14 | DisplayString (SIZE (0..3)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The unit's PPID revision. | |||||||||||||||||||||
| CdellNetCardServiceTag | 1.3.6.1.4.1.6027.3.26.1.2.4.1.15 | DisplayString (SIZE (0..7)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The unit's service tag. | |||||||||||||||||||||
| CdellNetCardExpServiceCode | 1.3.6.1.4.1.6027.3.26.1.2.4.1.16 | DisplayString (SIZE (0..14)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The unit's express service code. | |||||||||||||||||||||
| CdellNetCardNumOfPorts | 1.3.6.1.4.1.6027.3.26.1.2.4.1.17 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of interfaces in this unit. | |||||||||||||||||||||
| NdellNetStackObject | 1.3.6.1.4.1.6027.3.26.1.3 | ||||||||||||||||||||
| SdellNetNumStackUnits | 1.3.6.1.4.1.6027.3.26.1.3.1 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current The total number of stack units configured on the chassis. | |||||||||||||||||||||
| SdellNetMaxStackableUnits | 1.3.6.1.4.1.6027.3.26.1.3.2 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Indicates the maximum allowed Unit Number configurable on the chassis. | |||||||||||||||||||||
| SdellNetStackUnitIndexNext | 1.3.6.1.4.1.6027.3.26.1.3.3 | Integer32 (0 | 1..16) | RO | ||||||||||||||||||
scalar · Integer32 (0 | 1..16) · read-only · current This object contains the next appropriate value to be used for dellNetStackUnitIndex when creating entries in the dellNetStackUnitTable. The value 0 indicates that no unassigned entries are available. To obtain the dellNetStackUnitIndexNext value for a new entry, the manager must first issue a management protocol retrieval operation to obtain the current value of this object. The agent should modify the value to reflect the next unassigned number after each retrieval operation. After a manager retrieves a value the agent will determine when this index value will be made available for reuse. Note that this object is not the unit number assigned by the management unit. The max number of stackable units allowed on this chassis is found from the object dellNetNumMaxStackableUnits. | |||||||||||||||||||||
| TdellNetStackUnitTable | 1.3.6.1.4.1.6027.3.26.1.3.4 | NA | |||||||||||||||||||
table · not-accessible · current A list of stack units configured in the chassis. The StackUnit table contains the management information of each stacked unit in the chassis. | |||||||||||||||||||||
| RdellNetStackUnitEntry | 1.3.6.1.4.1.6027.3.26.1.3.4.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of units entries containing information for each stacked unit. | |||||||||||||||||||||
| CdellNetStackUnitIndex | 1.3.6.1.4.1.6027.3.26.1.3.4.1.1 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current The unique index for this entry. Refer to the object dellNetStackUnitIndexNext. | |||||||||||||||||||||
| CdellNetStackUnitNumber | 1.3.6.1.4.1.6027.3.26.1.3.4.1.2 | Integer32 (0 | 1..12) | RO | 1 | |||||||||||||||||
column · Integer32 (0 | 1..12) · read-only · current The unit number associated with this unit. The unit number can be manually assigned to stack members. Note that the unit number assignment is based on the following factors: - if the unit number is requested here, but another unit already uses that number, the unit changes its configured unit number to the lowest unassigned unit number. - if the unit number is 0, i.e. unassigned, then the unit sets its configured unit number to the lowest unassigned unit number. - if the unit number is configured and no other device uses the unit number, then the unit starts using the configured unit number. - if a unit detects that the maximum number of units already exist, the unit sets its unit number to 0, i.e. unassigned, and stays in the Initialization state. - The max number of stackable units allowed on this chassis is found from the object chNumMaxStackableUnits. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitMgmtStatus | 1.3.6.1.4.1.6027.3.26.1.3.4.1.4 | INTEGER | RO | mgmtUnit(1) | |||||||||||||||||
column · INTEGER · read-only · current Indicates whether the unit is a Management Unit, a Stack Unit, or unassigned. Setting this object to mgmtUnit(1) initiates transfer of the management functionality to the specified stack unit. Object values stackUnit(2) and unassigned(3) cannot be set.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitHwMgmtPreference | 1.3.6.1.4.1.6027.3.26.1.3.4.1.5 | INTEGER | RO | disabled(0) | |||||||||||||||||
column · INTEGER · read-only · current indicates whether the unit is capable of becoming a management unit. if it is unsigned, this unit can be a management unit.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitAdmMgmtPreference | 1.3.6.1.4.1.6027.3.26.1.3.4.1.6 | Integer32 (0 | 1..15) | RO | 0 | |||||||||||||||||
column · Integer32 (0 | 1..15) · read-only · current indicates how likely this unit is to be chosen as the management unit. A value of 0 indicates a disabled or unassigned preference. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitModelId | 1.3.6.1.4.1.6027.3.26.1.3.4.1.7 | DellNetChassisType | RO | 47 | |||||||||||||||||
column · DellNetChassisType · read-only · current The Dell Networking OS Model number for this unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitStatus | 1.3.6.1.4.1.6027.3.26.1.3.4.1.8 | INTEGER | RO | ok(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of this unit.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitDescription | 1.3.6.1.4.1.6027.3.26.1.3.4.1.9 | DisplayString | RO | 48x10G, 6x40G TE/FO G (S4048T-ON) | |||||||||||||||||
column · DisplayString · read-only · current The description of this unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitCodeVersion | 1.3.6.1.4.1.6027.3.26.1.3.4.1.10 | DisplayString | RO | 9.14(0.1) | |||||||||||||||||
column · DisplayString · read-only · current Current code version of this unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitSerialNumber | 1.3.6.1.4.1.6027.3.26.1.3.4.1.11 | DisplayString | RO | NA | |||||||||||||||||
column · DisplayString · read-only · current The unit's serial number. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitUpTime | 1.3.6.1.4.1.6027.3.26.1.3.4.1.12 | TimeTicks | RO | 331416000 (38d 8h 36m 0s) | |||||||||||||||||
column · TimeTicks · read-only · current The system up time of the unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitTemp | 1.3.6.1.4.1.6027.3.26.1.3.4.1.13 | Gauge32 | RO | 62 | |||||||||||||||||
column · Gauge32 · read-only · current The temperature of the unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitVendorId | 1.3.6.1.4.1.6027.3.26.1.3.4.1.14 | DisplayString | RO | DL | |||||||||||||||||
column · DisplayString · read-only · current The vendor id that manufactured this unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitMfgDate | 1.3.6.1.4.1.6027.3.26.1.3.4.1.15 | DellNetMfgDate | RO | 21062018 | |||||||||||||||||
column · DellNetMfgDate · read-only · current The date the unit is manufactured. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitMacAddress | 1.3.6.1.4.1.6027.3.26.1.3.4.1.16 | MacAddress | RO | e4:f0:04:e1:67:18 | |||||||||||||||||
column · MacAddress · read-only · current A 6-octet MAC Address assigned to this unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitPartNum | 1.3.6.1.4.1.6027.3.26.1.3.4.1.17 | DisplayString | RO | 06R5M0 | |||||||||||||||||
column · DisplayString · read-only · current The unit part number Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitProductRev | 1.3.6.1.4.1.6027.3.26.1.3.4.1.18 | DisplayString | RO | A01 | |||||||||||||||||
column · DisplayString · read-only · current The unit manufacturer's product revision Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitProductOrder | 1.3.6.1.4.1.6027.3.26.1.3.4.1.19 | DisplayString | RO | NA | |||||||||||||||||
column · DisplayString · read-only · current The product order number for this unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitCountryCode | 1.3.6.1.4.1.6027.3.26.1.3.4.1.20 | OCTET STRING (SIZE (2)) | RO | CN | |||||||||||||||||
column · OCTET STRING (SIZE (2)) · read-only · current The unit manufacturer's country code Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitPiecePartID | 1.3.6.1.4.1.6027.3.26.1.3.4.1.21 | DisplayString (SIZE (0..24)) | RO | CN-06R5M0-28298-86L-0113 | |||||||||||||||||
column · DisplayString (SIZE (0..24)) · read-only · current The unit's piece part id. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitPPIDRevision | 1.3.6.1.4.1.6027.3.26.1.3.4.1.22 | DisplayString (SIZE (0..3)) | RO | A01 | |||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The unit's PPID revision. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitServiceTag | 1.3.6.1.4.1.6027.3.26.1.3.4.1.23 | DisplayString (SIZE (0..7)) | RO | FXXXXX2 | |||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The unit's service tag. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitExpServiceCode | 1.3.6.1.4.1.6027.3.26.1.3.4.1.24 | DisplayString (SIZE (0..14)) | RO | 343 407 254 42 | |||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The unit's express service code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitNumOfPorts | 1.3.6.1.4.1.6027.3.26.1.3.4.1.25 | Integer32 | RO | 72 | |||||||||||||||||
column · Integer32 · read-only · current The number of interfaces in this unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitNumFanTrays | 1.3.6.1.4.1.6027.3.26.1.3.4.1.26 | Integer32 | RO | 4 | |||||||||||||||||
column · Integer32 · read-only · current The number of fan trays on the unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitNumPowerSupplies | 1.3.6.1.4.1.6027.3.26.1.3.4.1.27 | Integer32 | RO | 2 | |||||||||||||||||
column · Integer32 · read-only · current The number of power supply in the unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetStackUnitNumPluggableModules | 1.3.6.1.4.1.6027.3.26.1.3.4.1.28 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current The number of pluggable modules in the stack unit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TdellNetStackPortTable | 1.3.6.1.4.1.6027.3.26.1.3.5 | NA | |||||||||||||||||||
table · not-accessible · current A list of stack ports in the chassis. | |||||||||||||||||||||
| RdellNetStackPortEntry | 1.3.6.1.4.1.6027.3.26.1.3.5.1 | NA | |||||||||||||||||||
row · not-accessible · current A stack port entry containing objects for a particular stack port. | |||||||||||||||||||||
| CdellNetStackPortIndex | 1.3.6.1.4.1.6027.3.26.1.3.5.1.1 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The index for each stack port within the unit. 1 - stack port A, 2 - stack port B | |||||||||||||||||||||
| CdellNetStackPortConfiguredMode | 1.3.6.1.4.1.6027.3.26.1.3.5.1.2 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Configured mode of the Stack Port. Changes to this value happen only after a reset of the unit.
| |||||||||||||||||||||
| CdellNetStackPortRunningMode | 1.3.6.1.4.1.6027.3.26.1.3.5.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Operational mode of the Stack Port.
| |||||||||||||||||||||
| CdellNetStackPortLinkStatus | 1.3.6.1.4.1.6027.3.26.1.3.5.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current Link status of the Stack Port. Ports in ethernet mode will return a status of down(2).
| |||||||||||||||||||||
| CdellNetStackPortLinkSpeed | 1.3.6.1.4.1.6027.3.26.1.3.5.1.5 | Gauge32 | RO | ||||||||||||||||||
column · Gauge32 · read-only · current Speed of the Stack Port measured in Gb/s. Ports in ethernet mode will return a speed of 0. | |||||||||||||||||||||
| CdellNetStackPortRxDataRate | 1.3.6.1.4.1.6027.3.26.1.3.5.1.6 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current Received Data rate on the stacking port. Measured in Mb/s. Ports in ethernet mode will return 0. | |||||||||||||||||||||
| CdellNetStackPortRxErrorRate | 1.3.6.1.4.1.6027.3.26.1.3.5.1.7 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current Received error rate on the stack port. Measured in Errors per Second. Ports in ethernet mode will return 0. | |||||||||||||||||||||
| CdellNetStackPortRxTotalErrors | 1.3.6.1.4.1.6027.3.26.1.3.5.1.8 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current Received number of errors since boot. The counter may wrap. Ports in ethernet mode will return 0. | |||||||||||||||||||||
| CdellNetStackPortTxDataRate | 1.3.6.1.4.1.6027.3.26.1.3.5.1.9 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current Transmitted Data rate on the stacking port. Measured in Mb/s. Ports in ethernet mode will return 0. | |||||||||||||||||||||
| CdellNetStackPortTxErrorRate | 1.3.6.1.4.1.6027.3.26.1.3.5.1.10 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current Transmitted error rate on the stack port. Measured in Errors per Second. Ports in ethernet mode will return 0. | |||||||||||||||||||||
| CdellNetStackPortTxTotalErrors | 1.3.6.1.4.1.6027.3.26.1.3.5.1.11 | Counter32 | RO | ||||||||||||||||||
column · Counter32 · read-only · current Transmitted number of errors since boot. The counter may wrap. Ports in ethernet mode will return 0. | |||||||||||||||||||||
| NdellNetSystemComponent | 1.3.6.1.4.1.6027.3.26.1.4 | ||||||||||||||||||||
| TdellNetPEBindingTable | 1.3.6.1.4.1.6027.3.26.1.4.1 | NA | |||||||||||||||||||
table · not-accessible · current The dellNetPEBindingTable entry binds the core switch's port to the Port Extender connected to it.The table will hold an entry for port extenders physically connected or provisioned to be connected to the port. | |||||||||||||||||||||
| RdellNetPEBindingEntry | 1.3.6.1.4.1.6027.3.26.1.4.1.1 | NA | |||||||||||||||||||
row · not-accessible · current A PE binding entry binds the InterfaceIndex of the port in core switch to the dellNetPortExtenderIndex of Port extender connected to it or provisioned to be connected. | |||||||||||||||||||||
| CdellNetPEBindCascadePortIfIndex | 1.3.6.1.4.1.6027.3.26.1.4.1.1.1 | InterfaceIndex | NA | ||||||||||||||||||
column · InterfaceIndex · not-accessible · current This is a unique interface index of an physical interface in controller bridge or or PE uplink LAG interface to which the port externder with dellNetPEIndex is connected or provisioned. | |||||||||||||||||||||
| CdellNetPEBindPEIndex | 1.3.6.1.4.1.6027.3.26.1.4.1.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current An index that uniquely identifies a port extender controlled by the controller bridge.This is an index derived from the PEID and stack-unit ID of the port extender | |||||||||||||||||||||
| TdellNetPETable | 1.3.6.1.4.1.6027.3.26.1.4.2 | NA | |||||||||||||||||||
table · not-accessible · current The dellNetPETable lists port extenders controlled by the controller bridge. | |||||||||||||||||||||
| RdellNetPEEntry | 1.3.6.1.4.1.6027.3.26.1.4.2.1 | NA | |||||||||||||||||||
row · not-accessible · current A PE table entry holds details of port extenders controlled by the controller bridge.
| |||||||||||||||||||||
| CdellNetPEIndex | 1.3.6.1.4.1.6027.3.26.1.4.2.1.1 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current An index that uniquely identifies a port extender controlled by the controller bridge. | |||||||||||||||||||||
| CdellNetPEPEID | 1.3.6.1.4.1.6027.3.26.1.4.2.1.2 | Integer32 (1..255) | RO | ||||||||||||||||||
column · Integer32 (1..255) · read-only · current PEID assigned for the port extender. | |||||||||||||||||||||
| CdellNetPEUnitID | 1.3.6.1.4.1.6027.3.26.1.4.2.1.3 | Integer32 (1..255) | RO | ||||||||||||||||||
column · Integer32 (1..255) · read-only · current Stack unit ID assigned for the port extender. | |||||||||||||||||||||
| CdellNetPEType | 1.3.6.1.4.1.6027.3.26.1.4.2.1.4 | DellNetChassisType | RO | ||||||||||||||||||
column · DellNetChassisType · read-only · current Prt extender's type. | |||||||||||||||||||||
| CdellNetPEDescription | 1.3.6.1.4.1.6027.3.26.1.4.2.1.5 | DisplayString (SIZE (0..40)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..40)) · read-only · current A short description of the card. | |||||||||||||||||||||
| CdellNetPEStatus | 1.3.6.1.4.1.6027.3.26.1.4.2.1.6 | DellNetPEOperStatus | RO | ||||||||||||||||||
column · DellNetPEOperStatus · read-only · current The current operational state of the Port extender. | |||||||||||||||||||||
| CdellNetPETemp | 1.3.6.1.4.1.6027.3.26.1.4.2.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Temperature of the port extender
| |||||||||||||||||||||
| CdellNetPEVendorId | 1.3.6.1.4.1.6027.3.26.1.4.2.1.8 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The vendor id that manufactured this unit. | |||||||||||||||||||||
| CdellNetPEMfgDate | 1.3.6.1.4.1.6027.3.26.1.4.2.1.9 | DellNetMfgDate | RO | ||||||||||||||||||
column · DellNetMfgDate · read-only · current The date the unit is manufactured. | |||||||||||||||||||||
| CdellNetPEPartNum | 1.3.6.1.4.1.6027.3.26.1.4.2.1.10 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The unit part number | |||||||||||||||||||||
| CdellNetPEProductRev | 1.3.6.1.4.1.6027.3.26.1.4.2.1.11 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The unit manufacturer's product revision | |||||||||||||||||||||
| CdellNetPEProductOrder | 1.3.6.1.4.1.6027.3.26.1.4.2.1.12 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The product order number for this unit. | |||||||||||||||||||||
| CdellNetPECountryCode | 1.3.6.1.4.1.6027.3.26.1.4.2.1.13 | OCTET STRING (SIZE (2)) | RO | ||||||||||||||||||
column · OCTET STRING (SIZE (2)) · read-only · current The unit manufacturer's country code | |||||||||||||||||||||
| CdellNetPEPiecePartID | 1.3.6.1.4.1.6027.3.26.1.4.2.1.14 | DisplayString (SIZE (0..24)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..24)) · read-only · current The unit's piece part id. | |||||||||||||||||||||
| CdellNetPEPPIDRevision | 1.3.6.1.4.1.6027.3.26.1.4.2.1.15 | DisplayString (SIZE (0..3)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The unit's PPID revision. | |||||||||||||||||||||
| CdellNetPEServiceTag | 1.3.6.1.4.1.6027.3.26.1.4.2.1.16 | DisplayString (SIZE (0..7)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The unit's service tag. | |||||||||||||||||||||
| CdellNetPEExpServiceCode | 1.3.6.1.4.1.6027.3.26.1.4.2.1.17 | DisplayString (SIZE (0..14)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The unit's express service code. | |||||||||||||||||||||
| CdellNetPENumOfPorts | 1.3.6.1.4.1.6027.3.26.1.4.2.1.18 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of interfaces in this unit. | |||||||||||||||||||||
| CdellNetPENumFanTrays | 1.3.6.1.4.1.6027.3.26.1.4.2.1.19 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of fan trays on the unit. | |||||||||||||||||||||
| CdellNetPENumPowerSupplies | 1.3.6.1.4.1.6027.3.26.1.4.2.1.20 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of power supply in the unit. | |||||||||||||||||||||
| CdellNetPENumPluggableModules | 1.3.6.1.4.1.6027.3.26.1.4.2.1.21 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The number of pluggable modules in the unit. | |||||||||||||||||||||
| TdellNetProcessorTable | 1.3.6.1.4.1.6027.3.26.1.4.3 | NA | |||||||||||||||||||
table · not-accessible · current A list of Processors resident in this slot. | |||||||||||||||||||||
| RdellNetProcessorEntry | 1.3.6.1.4.1.6027.3.26.1.4.3.1 | NA | |||||||||||||||||||
row · not-accessible · current A list of Processor entries. | |||||||||||||||||||||
| CdellNetProcessorDeviceType | 1.3.6.1.4.1.6027.3.26.1.4.3.1.1 | DellNetDeviceType | NA | ||||||||||||||||||
column · DellNetDeviceType · not-accessible · current Identify the type of device the processor reside (linecard,port extender etc..) | |||||||||||||||||||||
| CdellNetProcessorDeviceIndex | 1.3.6.1.4.1.6027.3.26.1.4.3.1.2 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current A unique device index within the device type. | |||||||||||||||||||||
| CdellNetProcessorIndex | 1.3.6.1.4.1.6027.3.26.1.4.3.1.3 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current A unique index for each Processor within the device.The valid entries are 1 to the value of number of processors | |||||||||||||||||||||
| CdellNetProcessorModule | 1.3.6.1.4.1.6027.3.26.1.4.3.1.4 | DellNetProcessorModuleType | RO | 4 | |||||||||||||||||
column · DellNetProcessorModuleType · read-only · current The type of module running on the Processor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetProcessorUpTime | 1.3.6.1.4.1.6027.3.26.1.4.3.1.5 | TimeTicks | RO | 331416000 (38d 8h 36m 0s) | |||||||||||||||||
column · TimeTicks · read-only · current The SysUpTime for this Processor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetProcessorMemSize | 1.3.6.1.4.1.6027.3.26.1.4.3.1.6 | Integer32 | RO | 2048 | |||||||||||||||||
column · Integer32 · read-only · current The size of the RAM in Mb. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TdellNetCpuUtilTable | 1.3.6.1.4.1.6027.3.26.1.4.4 | NA | |||||||||||||||||||
table · not-accessible · current A table listing the processor and memory utilization of of each CPU in the system. | |||||||||||||||||||||
| RdellNetCpuUtilEntry | 1.3.6.1.4.1.6027.3.26.1.4.4.1 | NA | |||||||||||||||||||
row · not-accessible · current Processor and Memory Utilization entry for a particular CPU. | |||||||||||||||||||||
| CdellNetCpuUtil5Sec | 1.3.6.1.4.1.6027.3.26.1.4.4.1.1 | Gauge32 (0..100) | RO | 11 | |||||||||||||||||
column · Gauge32 (0..100) · read-only · current CPU utilization in percentage for last 5 seconds.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetCpuUtil1Min | 1.3.6.1.4.1.6027.3.26.1.4.4.1.4 | Gauge32 (0..100) | RO | 12 | |||||||||||||||||
column · Gauge32 (0..100) · read-only · current CPU utilization in percentage for last 1 minute.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetCpuUtil5Min | 1.3.6.1.4.1.6027.3.26.1.4.4.1.5 | Gauge32 (0..100) | RO | 8 | |||||||||||||||||
column · Gauge32 (0..100) · read-only · current CPU utilization in percentage for last 5 minutes.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetCpuUtilMemUsage | 1.3.6.1.4.1.6027.3.26.1.4.4.1.6 | Gauge32 (0..100) | RO | 30 | |||||||||||||||||
column · Gauge32 (0..100) · read-only · current Total Memory usage in percentage.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetCpuFlashUsageUtil | 1.3.6.1.4.1.6027.3.26.1.4.4.1.7 | Gauge32 (0..100) | RO | 4 | |||||||||||||||||
column · Gauge32 (0..100) · read-only · current Total flash usage in percentage.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| TdellNetSwModuleTable | 1.3.6.1.4.1.6027.3.26.1.4.5 | NA | |||||||||||||||||||
table · not-accessible · current A list of software version information in a processor. | |||||||||||||||||||||
| RdellNetSwModuleEntry | 1.3.6.1.4.1.6027.3.26.1.4.5.1 | NA | |||||||||||||||||||
row · not-accessible · current A software module entry containing version number information for a particular processor. | |||||||||||||||||||||
| CdellNetSwModuleRuntimeImgVersion | 1.3.6.1.4.1.6027.3.26.1.4.5.1.1 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current Current Dell Networking OS image version running in the system. The version string will be in following format major_ver.minor_ver(maintenance_ver.patch_ver) | |||||||||||||||||||||
| CdellNetSwModuleRuntimeImgDate | 1.3.6.1.4.1.6027.3.26.1.4.5.1.2 | DellNetSwDate (SIZE (0..10)) | RO | ||||||||||||||||||
column · DellNetSwDate (SIZE (0..10)) · read-only · current The release date of this software module. | |||||||||||||||||||||
| CdellNetSwModuleBootFlashImgVersion | 1.3.6.1.4.1.6027.3.26.1.4.5.1.3 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This provides the Grub image version that is currently running in the processor. | |||||||||||||||||||||
| CdellNetSwModuleBootSelectorImgVersion | 1.3.6.1.4.1.6027.3.26.1.4.5.1.4 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This provides the BIOS image version that is currently running in the processor. | |||||||||||||||||||||
| CdellNetSwModuleNextRebootImage | 1.3.6.1.4.1.6027.3.26.1.4.5.1.5 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The image selection, when the chassis is rebooted. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - will be booted via network.
| |||||||||||||||||||||
| CdellNetSwModuleCurrentBootImage | 1.3.6.1.4.1.6027.3.26.1.4.5.1.6 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The current image is booted from. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - Booted via network.
| |||||||||||||||||||||
| CdellNetSwModuleInPartitionAImgVers | 1.3.6.1.4.1.6027.3.26.1.4.5.1.7 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This provides the Dell Networking OS system image version that is stored in partition A: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or Generally Available | |||||||||||||||||||||
| CdellNetSwModuleInPartitionBImgVers | 1.3.6.1.4.1.6027.3.26.1.4.5.1.8 | DisplayString (SIZE (0..32)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..32)) · read-only · current This provides the Dell Networking OS system image version that is stored in partition B: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or Generally Available | |||||||||||||||||||||
| TdellNetPowerSupplyTable | 1.3.6.1.4.1.6027.3.26.1.4.6 | NA | |||||||||||||||||||
table · not-accessible · current A list of power supply resident in the device. | |||||||||||||||||||||
| RdellNetPowerSupplyEntry | 1.3.6.1.4.1.6027.3.26.1.4.6.1 | NA | |||||||||||||||||||
row · not-accessible · current A power supply entry containing objects for a particular power supply. | |||||||||||||||||||||
| CdellNetPowerDeviceType | 1.3.6.1.4.1.6027.3.26.1.4.6.1.1 | DellNetDeviceType | NA | ||||||||||||||||||
column · DellNetDeviceType · not-accessible · current Identify the type of device the power supply units reside (chassis,port extender etc..) | |||||||||||||||||||||
| CdellNetPowerDeviceIndex | 1.3.6.1.4.1.6027.3.26.1.4.6.1.2 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current A unique device index within the device type. | |||||||||||||||||||||
| CdellNetPowerSupplyIndex | 1.3.6.1.4.1.6027.3.26.1.4.6.1.3 | Integer32 | RO | 1 | |||||||||||||||||
| CdellNetPowerSupplyOperStatus | 1.3.6.1.4.1.6027.3.26.1.4.6.1.4 | INTEGER | RO | up(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of the power supply.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetPowerSupplyType | 1.3.6.1.4.1.6027.3.26.1.4.6.1.5 | INTEGER | RO | ac(2) | |||||||||||||||||
column · INTEGER · read-only · current The type of the power supply.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetPowerSupplyPiecePartID | 1.3.6.1.4.1.6027.3.26.1.4.6.1.6 | DisplayString (SIZE (0..24)) | RO | CN-06FKHH-28298-857-06PD | |||||||||||||||||
column · DisplayString (SIZE (0..24)) · read-only · current The power supply's piece part id. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetPowerSupplyPPIDRevision | 1.3.6.1.4.1.6027.3.26.1.4.6.1.7 | DisplayString (SIZE (0..3)) | RO | A01 | |||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The power supply's PPID revision. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetPowerSupplyServiceTag | 1.3.6.1.4.1.6027.3.26.1.4.6.1.8 | DisplayString (SIZE (0..7)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The power supply's service tag. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetPowerSupplyExpressServiceCode | 1.3.6.1.4.1.6027.3.26.1.4.6.1.9 | DisplayString (SIZE (0..14)) | RO | NA | |||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The power supply's express service code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetPowerSupplyUsage | 1.3.6.1.4.1.6027.3.26.1.4.6.1.10 | Integer32 | RO | 23 | |||||||||||||||||
column · Integer32 · read-only · current Power usage of this Power Supply in Watts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TdellNetFanTrayTable | 1.3.6.1.4.1.6027.3.26.1.4.7 | NA | |||||||||||||||||||
table · not-accessible · current A list of fan tray resident in the device. | |||||||||||||||||||||
| RdellNetFanTrayEntry | 1.3.6.1.4.1.6027.3.26.1.4.7.1 | NA | |||||||||||||||||||
row · not-accessible · current A fan entry containing objects for a particular fan tray. | |||||||||||||||||||||
| CdellNetFanDeviceType | 1.3.6.1.4.1.6027.3.26.1.4.7.1.1 | DellNetDeviceType | NA | ||||||||||||||||||
column · DellNetDeviceType · not-accessible · current Identify the type of device the fan tray units reside (chassis,port extender etc..) | |||||||||||||||||||||
| CdellNetFanDeviceIndex | 1.3.6.1.4.1.6027.3.26.1.4.7.1.2 | Integer32 | NA | ||||||||||||||||||
column · Integer32 · not-accessible · current A unique device index within the device type. | |||||||||||||||||||||
| CdellNetFanTrayIndex | 1.3.6.1.4.1.6027.3.26.1.4.7.1.3 | Integer32 | RO | 1 | |||||||||||||||||
| CdellNetFanTrayOperStatus | 1.3.6.1.4.1.6027.3.26.1.4.7.1.4 | INTEGER | RO | up(1) | |||||||||||||||||
column · INTEGER · read-only · current The status of the fan tray.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetFanTrayPiecePartID | 1.3.6.1.4.1.6027.3.26.1.4.7.1.5 | DisplayString (SIZE (0..24)) | RO | CN-061DJT-28298-86J-0621 | |||||||||||||||||
| CdellNetFanTrayPPIDRevision | 1.3.6.1.4.1.6027.3.26.1.4.7.1.6 | DisplayString (SIZE (0..3)) | RO | A00 | |||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current The fan tray's PPID revision. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetFanTrayServiceTag | 1.3.6.1.4.1.6027.3.26.1.4.7.1.7 | DisplayString (SIZE (0..7)) | RO | | |||||||||||||||||
column · DisplayString (SIZE (0..7)) · read-only · current The fan tray's service tag. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdellNetFanTrayExpressServiceCode | 1.3.6.1.4.1.6027.3.26.1.4.7.1.8 | DisplayString (SIZE (0..14)) | RO | NA | |||||||||||||||||
column · DisplayString (SIZE (0..14)) · read-only · current The fan tray's express service code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TdellNetSysSwCoresTable | 1.3.6.1.4.1.6027.3.26.1.4.9 | NA | |||||||||||||||||||
table · not-accessible · current A table containing information about the software cores that have been generated as a result of system failures. | |||||||||||||||||||||
| RdellNetSysCoresEntry | 1.3.6.1.4.1.6027.3.26.1.4.9.1 | NA | |||||||||||||||||||
row · not-accessible · current A row in the software core table representing information about a core that has been generated. | |||||||||||||||||||||
| CdellNetSysCoresInstance | 1.3.6.1.4.1.6027.3.26.1.4.9.1.1 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current A unique index assigned to the cores stored on this stack unit. | |||||||||||||||||||||
| CdellNetSysCoresFileName | 1.3.6.1.4.1.6027.3.26.1.4.9.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The name of the core file including the path. | |||||||||||||||||||||
| CdellNetSysCoresTimeCreated | 1.3.6.1.4.1.6027.3.26.1.4.9.1.3 | DellNetSwDate | RO | ||||||||||||||||||
column · DellNetSwDate · read-only · current The time at which the core file was created. | |||||||||||||||||||||
| CdellNetSysCoresStackUnitNumber | 1.3.6.1.4.1.6027.3.26.1.4.9.1.4 | Integer32 (1..12) | RO | ||||||||||||||||||
column · Integer32 (1..12) · read-only · current The stack unit member which generated the core. | |||||||||||||||||||||
| CdellNetSysCoresProcess | 1.3.6.1.4.1.6027.3.26.1.4.9.1.5 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current The name of the process which generated the core. | |||||||||||||||||||||
| TdellNetSysIfTable | 1.3.6.1.4.1.6027.3.26.1.4.10 | NA | |||||||||||||||||||
table · not-accessible · current A list of intefaces in the S-series chassis. This table is similar to chSysPortTable but supported only for ON platforms due to change in numbering scheme. | |||||||||||||||||||||
| RdellNetSysIfEntry | 1.3.6.1.4.1.6027.3.26.1.4.10.1 | NA | |||||||||||||||||||
row · not-accessible · current A interface entry containing objects for a particular interface.
| |||||||||||||||||||||
| CdellNetSysIfType | 1.3.6.1.4.1.6027.3.26.1.4.10.1.1 | DellNetIfType | RO | ||||||||||||||||||
column · DellNetIfType · read-only · current The type of Interface. | |||||||||||||||||||||
| CdellNetSysIfName | 1.3.6.1.4.1.6027.3.26.1.4.10.1.2 | DisplayString | RO | ||||||||||||||||||
column · DisplayString · read-only · current Display name of the interface. | |||||||||||||||||||||
| CdellNetSysIfAdminStatus | 1.3.6.1.4.1.6027.3.26.1.4.10.1.3 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The admin status of the interface. The interface admin status is Up if the user has configured it to be up otherwise, the admin status is Down.
| |||||||||||||||||||||
| CdellNetSysIfOperStatus | 1.3.6.1.4.1.6027.3.26.1.4.10.1.4 | INTEGER | RO | ||||||||||||||||||
column · INTEGER · read-only · current The operational status provides further
condition of the interface.
If the dellNetSysIfAdminStatus is 'up', the
valid state is
'ready' - the card is present and
ready and the dellNetSysIfAdminStatus
status is 'up'.
'portDown' - the interface is down or not enabled.
'portProblem' - interface hardware problems.
'cardProblem' - not used. Same as cardDown.
'cardDown' - the card is down.
'notPresent' - the card is not present.
| |||||||||||||||||||||
| CdellNetSysIfXfpRecvPower | 1.3.6.1.4.1.6027.3.26.1.4.10.1.5 | DellNetHundredthdB | RO | ||||||||||||||||||
column · DellNetHundredthdB · read-only · current The power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface.
| |||||||||||||||||||||
| CdellNetSysIfXfpRecvTemp | 1.3.6.1.4.1.6027.3.26.1.4.10.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The temperature value received for the optics. | |||||||||||||||||||||
| CdellNetSysIfXfpTxPower | 1.3.6.1.4.1.6027.3.26.1.4.10.1.7 | DellNetHundredthdB | RO | ||||||||||||||||||
column · DellNetHundredthdB · read-only · current The power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.
| |||||||||||||||||||||
| NdellNetSysAlarmObjects | 1.3.6.1.4.1.6027.3.26.1.5 | ||||||||||||||||||||
| NdellNetSysAlarmMibNotifications | 1.3.6.1.4.1.6027.3.26.1.5.1 | ||||||||||||||||||||
| !dellNetSysAlarmCardDown | 1.3.6.1.4.1.6027.3.26.1.5.1.1 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a card operational status is down. | |||||||||||||||||||||
| !dellNetSysAlarmCardUp | 1.3.6.1.4.1.6027.3.26.1.5.1.2 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a card operational status is up. | |||||||||||||||||||||
| !dellNetSysAlarmCardOffline | 1.3.6.1.4.1.6027.3.26.1.5.1.3 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a card is set to offline. | |||||||||||||||||||||
| !dellNetSysAlarmCardMismatch | 1.3.6.1.4.1.6027.3.26.1.5.1.4 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a card is not the same as configured | |||||||||||||||||||||
| !dellNetSysAlarmRpmUp | 1.3.6.1.4.1.6027.3.26.1.5.1.5 | ||||||||||||||||||||
notification · current The primary RPM generate this trap when the primary RPM or the secondary RPM is up and running. | |||||||||||||||||||||
| !dellNetSysAlarmRpmDown | 1.3.6.1.4.1.6027.3.26.1.5.1.6 | ||||||||||||||||||||
notification · current The primary RPM generate this trap when the secondary RPM is down, either by software reset or being physically removed from the chassis. | |||||||||||||||||||||
| !dellNetSysAlarmPowersupplyDown | 1.3.6.1.4.1.6027.3.26.1.5.1.7 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a power supply is not operational. | |||||||||||||||||||||
| !dellNetSysAlarmMinorTemperatureHigh | 1.3.6.1.4.1.6027.3.26.1.5.1.8 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when the chassis's temperature exceed the minor threshold. | |||||||||||||||||||||
| !dellNetSysAlarmMajorTemperatureHigh | 1.3.6.1.4.1.6027.3.26.1.5.1.9 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when the chassis's temperature exceede the major threshold. | |||||||||||||||||||||
| !dellNetSysAlarmFanTrayDown | 1.3.6.1.4.1.6027.3.26.1.5.1.10 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a fan tray is missing or down. | |||||||||||||||||||||
| !dellNetSysAlarmPowersupplyClear | 1.3.6.1.4.1.6027.3.26.1.5.1.11 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a power supply is now operational. | |||||||||||||||||||||
| !dellNetSysAlarmMinorTemperatureClear | 1.3.6.1.4.1.6027.3.26.1.5.1.12 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when the chassis's temperature within the minor threshold. | |||||||||||||||||||||
| !dellNetSysAlarmMajorTemperatureClear | 1.3.6.1.4.1.6027.3.26.1.5.1.13 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when the chassis's temperature within the major threshold. | |||||||||||||||||||||
| !dellNetSysAlarmFanTrayClear | 1.3.6.1.4.1.6027.3.26.1.5.1.14 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a fan tray is now operational. | |||||||||||||||||||||
| !dellNetSysAlarmMinorFanBadClear | 1.3.6.1.4.1.6027.3.26.1.5.1.15 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a minor fan tray that was bad is now operational. | |||||||||||||||||||||
| !dellNetSysAlarmMajorPS | 1.3.6.1.4.1.6027.3.26.1.5.1.16 | ||||||||||||||||||||
notification · current The agent generate this trap when a power supply major alarm is issued. | |||||||||||||||||||||
| !dellNetSysAlarmMajorPSClr | 1.3.6.1.4.1.6027.3.26.1.5.1.17 | ||||||||||||||||||||
notification · current The agent generate this trap when a power supply major alarm is cleared. | |||||||||||||||||||||
| !dellNetSysAlarmMinorPS | 1.3.6.1.4.1.6027.3.26.1.5.1.18 | ||||||||||||||||||||
notification · current The agent generate this trap when a power supply minor alarm is issued. | |||||||||||||||||||||
| !dellNetSysAlarmMinorPSClr | 1.3.6.1.4.1.6027.3.26.1.5.1.19 | ||||||||||||||||||||
notification · current The agent generate this trap when a power supply minor alarm is cleared. | |||||||||||||||||||||
| !dellNetSysAlarmMinorFanBad | 1.3.6.1.4.1.6027.3.26.1.5.1.20 | ||||||||||||||||||||
notification · current The agent generate this trap when fan is bad. | |||||||||||||||||||||
| !dellNetSysAlarmRpmPrimary | 1.3.6.1.4.1.6027.3.26.1.5.1.21 | ||||||||||||||||||||
notification · current The agent generate this trap when a standby RPM become Primary RPM after fail-over. | |||||||||||||||||||||
| !dellNetSysSnmpIpAclDeny | 1.3.6.1.4.1.6027.3.26.1.5.1.22 | ||||||||||||||||||||
notification · current The agent generate this trap when SNMP Agent deny a SNMP request based on the IP ACL rules. | |||||||||||||||||||||
| !dellNetSysAlarmCardVersionMismatch | 1.3.6.1.4.1.6027.3.26.1.5.1.23 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a card is not the same software version as a Management unit. Applied to S-series stackin only. | |||||||||||||||||||||
| !dellNetSysAlarmUnsupportedOptic | 1.3.6.1.4.1.6027.3.26.1.5.1.24 | ||||||||||||||||||||
notification · current The Interface Agent generate this trap when an unsupported optic is inserted in a port | |||||||||||||||||||||
| !dellNetSysAlarmFanTrayOrPsuDown | 1.3.6.1.4.1.6027.3.26.1.5.1.25 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a fan tray or psu is missing or down. | |||||||||||||||||||||
| !dellNetSysAlarmFanTrayOrPsuClear | 1.3.6.1.4.1.6027.3.26.1.5.1.26 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a fan tray or psu is now operational. | |||||||||||||||||||||
| !dellNetSysAlarmPEUp | 1.3.6.1.4.1.6027.3.26.1.5.1.27 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a PE operational status is up. | |||||||||||||||||||||
| !dellNetSysAlarmPEDown | 1.3.6.1.4.1.6027.3.26.1.5.1.28 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a PE operational status is down. | |||||||||||||||||||||
| !dellNetSysAlarmPEUnitUp | 1.3.6.1.4.1.6027.3.26.1.5.1.29 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a PE Unit operational status is up. | |||||||||||||||||||||
| !dellNetSysAlarmPEUnitDown | 1.3.6.1.4.1.6027.3.26.1.5.1.30 | ||||||||||||||||||||
notification · current The driver/agent generate this trap when a PE Unit operational status is down. | |||||||||||||||||||||
| !dellNetSysAlarmExdCpuThreshold | 1.3.6.1.4.1.6027.3.26.1.5.1.31 | ||||||||||||||||||||
notification · current The agent generate this trap when cpu utilization excceded 80%. | |||||||||||||||||||||
| !dellNetSysAlarmClrCpuThreshold | 1.3.6.1.4.1.6027.3.26.1.5.1.32 | ||||||||||||||||||||
notification · current The agent generate this trap when cpu utilization falls below threshold. | |||||||||||||||||||||
| !dellNetSysAlarmExdMemThreshold | 1.3.6.1.4.1.6027.3.26.1.5.1.33 | ||||||||||||||||||||
notification · current The agent generate this trap when memory utilization excceded 92%. | |||||||||||||||||||||
| !dellNetSysAlarmClrMemThreshold | 1.3.6.1.4.1.6027.3.26.1.5.1.34 | ||||||||||||||||||||
notification · current The agent generate this trap when memory utilization falls below threshold. | |||||||||||||||||||||
| !dellNetSysAlarmTaskSuspend | 1.3.6.1.4.1.6027.3.26.1.5.1.35 | ||||||||||||||||||||
notification · current The system generate this trap when a a task is suspended. | |||||||||||||||||||||
| !dellNetSysAlarmTaskTerm | 1.3.6.1.4.1.6027.3.26.1.5.1.36 | ||||||||||||||||||||
notification · current The system generate this trap when a a task is terminated. | |||||||||||||||||||||
| !dellNetSysAlarmMacStationMove | 1.3.6.1.4.1.6027.3.26.1.5.1.37 | ||||||||||||||||||||
notification · current The agent generate this trap when a MAC station move exceed the threshold. | |||||||||||||||||||||
| !dellNetSysAlarmCardReset | 1.3.6.1.4.1.6027.3.26.1.5.1.38 | deprecated | |||||||||||||||||||
notification · deprecated The driver/agent generate this trap when a card is reset. | |||||||||||||||||||||
| !dellNetSysAlarmCardRemove | 1.3.6.1.4.1.6027.3.26.1.5.1.39 | deprecated | |||||||||||||||||||
notification · deprecated The driver/agent generate this trap when a card is removed | |||||||||||||||||||||
| !dellNetSysAlarmCardProblem | 1.3.6.1.4.1.6027.3.26.1.5.1.40 | deprecated | |||||||||||||||||||
notification · deprecated The driver/agent generate this trap when a card is indicated wht status card problem | |||||||||||||||||||||
| !dellNetSysAlarmCutoff | 1.3.6.1.4.1.6027.3.26.1.5.1.41 | deprecated | |||||||||||||||||||
notification · deprecated This trap is generated if the alarm cut off button on RPM is pressed. | |||||||||||||||||||||
| !dellNetSysAlarmSRAMParityErrorDetect | 1.3.6.1.4.1.6027.3.26.1.5.1.42 | deprecated | |||||||||||||||||||
notification · deprecated The agent generate this trap when a linecard detects SRAM parity error and then tries to recover but can't recover that section. | |||||||||||||||||||||
| !dellNetSysAlarmAcDcMixedPowerSupplyDetect | 1.3.6.1.4.1.6027.3.26.1.5.1.43 | deprecated | |||||||||||||||||||
notification · deprecated The agent generate this trap when a system detects AC and DC mixed power supply. Applied to C-series only. | |||||||||||||||||||||
| !dellNetSysAlarmVrrpGoMaster | 1.3.6.1.4.1.6027.3.26.1.5.1.44 | deprecated | |||||||||||||||||||
notification · deprecated The VRRP generate this trap when it become a backup | |||||||||||||||||||||
| !dellNetSysAlarmVrrpGiveupMaster | 1.3.6.1.4.1.6027.3.26.1.5.1.45 | deprecated | |||||||||||||||||||
notification · deprecated The VRRP generate this trap when it is no longer the master and has entered non-operational state. | |||||||||||||||||||||
| NdellNetSysAlarmVariable | 1.3.6.1.4.1.6027.3.26.1.5.2 | ||||||||||||||||||||
| SdellNetSysAlarmVarInteger | 1.3.6.1.4.1.6027.3.26.1.5.2.1 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current An generic integer value in the TRAP object | |||||||||||||||||||||
| SdellNetSysAlarmVarString | 1.3.6.1.4.1.6027.3.26.1.5.2.2 | OCTET STRING | AN | ||||||||||||||||||
scalar · OCTET STRING · accessible-for-notify · current An generic string value in the TRAP object | |||||||||||||||||||||
| SdellNetSysAlarmVarSlot | 1.3.6.1.4.1.6027.3.26.1.5.2.3 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The chassis slot number. For the traps that does not have slot information the value will -1 in the TRAP PDU. | |||||||||||||||||||||
| SdellNetSysAlarmVarPort | 1.3.6.1.4.1.6027.3.26.1.5.2.4 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The chassis port number. For the traps that does not have port information the value will -1 in the TRAP PDU. | |||||||||||||||||||||
| SdellNetSysAlarmVarChassisId | 1.3.6.1.4.1.6027.3.26.1.5.2.5 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The Chassis ID. For the traps that does not have Chassis information the value will be -1 in the TRAP PDU. For Non-ON based platforms, the value is 0 based and for ON Based platform it is 1 based in the Trap PDU. | |||||||||||||||||||||
| SdellNetsysAlarmVarFanTrayId | 1.3.6.1.4.1.6027.3.26.1.5.2.6 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The FanTray ID. For the traps that does not have FanTray ID the value will be -1 in the TRAP PDU. For Non-ON based platforms, the value is 0 based and for ON Based platform it is 1 based in the Trap PDU. | |||||||||||||||||||||
| SdellNetsysAlarmVarPsuId | 1.3.6.1.4.1.6027.3.26.1.5.2.7 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The PSU ID. For the traps that does not have PSU Id the value will be -1 in the TRAP PDU. For Non-ON based platforms, the value is 0 based and for ON Based platform it is 1 based in the Trap PDU. | |||||||||||||||||||||
| SdellNetsysAlarmVarFanId | 1.3.6.1.4.1.6027.3.26.1.5.2.8 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The Fan ID. For the traps that does not have Fan Id the value will be -1 in the TRAP PDU. For Non-ON based platforms, the value is 0 based and for ON Based platform it is 1 based in the Trap PDU. | |||||||||||||||||||||
| SdellNetSysAlarmVarPeId | 1.3.6.1.4.1.6027.3.26.1.5.2.9 | INTEGER | AN | ||||||||||||||||||
scalar · INTEGER · accessible-for-notify · current The Pe ID. For the traps that does not have PE Id information the value will be -1 in the TRAP PDU. | |||||||||||||||||||||
| NdellNetChassisMibConformance | 1.3.6.1.4.1.6027.3.26.2 | ||||||||||||||||||||
| NdellNetChassisMibCompliances | 1.3.6.1.4.1.6027.3.26.2.1 | ||||||||||||||||||||
| MdellNetChassisMibCompliance | 1.3.6.1.4.1.6027.3.26.2.1.1 | ||||||||||||||||||||
compliance · current The compliance statement for Dell Networking OS product which implement the Dell Networking Chassis MIB. | |||||||||||||||||||||
| NdellNetChassisMibGroups | 1.3.6.1.4.1.6027.3.26.2.2 | ||||||||||||||||||||
| GdellNetComponentGroup | 1.3.6.1.4.1.6027.3.26.2.2.1 | ||||||||||||||||||||
group · current A collection of objects providing the overall chassis information.
| |||||||||||||||||||||
| GdellNetSystemGroup | 1.3.6.1.4.1.6027.3.26.2.2.2 | ||||||||||||||||||||
group · current A collection of objects providing the chassis system hardware information.
| |||||||||||||||||||||
| GdellNetChassisNotificationGroup | 1.3.6.1.4.1.6027.3.26.2.2.3 | ||||||||||||||||||||
group · current Notifications for Dell Networking OS Chassis mib
| |||||||||||||||||||||
Traps / Notifications
- dellNetSysAlarmAcDcMixedPowerSupplyDetect
1.3.6.1.4.1.6027.3.26.1.5.1.43 - dellNetSysAlarmCardDown
1.3.6.1.4.1.6027.3.26.1.5.1.1 - dellNetSysAlarmCardMismatch
1.3.6.1.4.1.6027.3.26.1.5.1.4 - dellNetSysAlarmCardOffline
1.3.6.1.4.1.6027.3.26.1.5.1.3 - dellNetSysAlarmCardProblem
1.3.6.1.4.1.6027.3.26.1.5.1.40 - dellNetSysAlarmCardRemove
1.3.6.1.4.1.6027.3.26.1.5.1.39 - dellNetSysAlarmCardReset
1.3.6.1.4.1.6027.3.26.1.5.1.38 - dellNetSysAlarmCardUp
1.3.6.1.4.1.6027.3.26.1.5.1.2 - dellNetSysAlarmCardVersionMismatch
1.3.6.1.4.1.6027.3.26.1.5.1.23 - dellNetSysAlarmClrCpuThreshold
1.3.6.1.4.1.6027.3.26.1.5.1.32 - dellNetSysAlarmClrMemThreshold
1.3.6.1.4.1.6027.3.26.1.5.1.34 - dellNetSysAlarmCutoff
1.3.6.1.4.1.6027.3.26.1.5.1.41 - dellNetSysAlarmExdCpuThreshold
1.3.6.1.4.1.6027.3.26.1.5.1.31 - dellNetSysAlarmExdMemThreshold
1.3.6.1.4.1.6027.3.26.1.5.1.33 - dellNetSysAlarmFanTrayClear
1.3.6.1.4.1.6027.3.26.1.5.1.14 - dellNetSysAlarmFanTrayDown
1.3.6.1.4.1.6027.3.26.1.5.1.10 - dellNetSysAlarmFanTrayOrPsuClear
1.3.6.1.4.1.6027.3.26.1.5.1.26 - dellNetSysAlarmFanTrayOrPsuDown
1.3.6.1.4.1.6027.3.26.1.5.1.25 - dellNetSysAlarmMacStationMove
1.3.6.1.4.1.6027.3.26.1.5.1.37 - dellNetSysAlarmMajorPS
1.3.6.1.4.1.6027.3.26.1.5.1.16 - dellNetSysAlarmMajorPSClr
1.3.6.1.4.1.6027.3.26.1.5.1.17 - dellNetSysAlarmMajorTemperatureClear
1.3.6.1.4.1.6027.3.26.1.5.1.13 - dellNetSysAlarmMajorTemperatureHigh
1.3.6.1.4.1.6027.3.26.1.5.1.9 - dellNetSysAlarmMinorFanBad
1.3.6.1.4.1.6027.3.26.1.5.1.20 - dellNetSysAlarmMinorFanBadClear
1.3.6.1.4.1.6027.3.26.1.5.1.15 - dellNetSysAlarmMinorPS
1.3.6.1.4.1.6027.3.26.1.5.1.18 - dellNetSysAlarmMinorPSClr
1.3.6.1.4.1.6027.3.26.1.5.1.19 - dellNetSysAlarmMinorTemperatureClear
1.3.6.1.4.1.6027.3.26.1.5.1.12 - dellNetSysAlarmMinorTemperatureHigh
1.3.6.1.4.1.6027.3.26.1.5.1.8 - dellNetSysAlarmPEDown
1.3.6.1.4.1.6027.3.26.1.5.1.28 - dellNetSysAlarmPEUnitDown
1.3.6.1.4.1.6027.3.26.1.5.1.30 - dellNetSysAlarmPEUnitUp
1.3.6.1.4.1.6027.3.26.1.5.1.29 - dellNetSysAlarmPEUp
1.3.6.1.4.1.6027.3.26.1.5.1.27 - dellNetSysAlarmPowersupplyClear
1.3.6.1.4.1.6027.3.26.1.5.1.11 - dellNetSysAlarmPowersupplyDown
1.3.6.1.4.1.6027.3.26.1.5.1.7 - dellNetSysAlarmRpmDown
1.3.6.1.4.1.6027.3.26.1.5.1.6 - dellNetSysAlarmRpmPrimary
1.3.6.1.4.1.6027.3.26.1.5.1.21 - dellNetSysAlarmRpmUp
1.3.6.1.4.1.6027.3.26.1.5.1.5 - dellNetSysAlarmSRAMParityErrorDetect
1.3.6.1.4.1.6027.3.26.1.5.1.42 - dellNetSysAlarmTaskSuspend
1.3.6.1.4.1.6027.3.26.1.5.1.35 - dellNetSysAlarmTaskTerm
1.3.6.1.4.1.6027.3.26.1.5.1.36 - dellNetSysAlarmUnsupportedOptic
1.3.6.1.4.1.6027.3.26.1.5.1.24 - dellNetSysAlarmVrrpGiveupMaster
1.3.6.1.4.1.6027.3.26.1.5.1.45 - dellNetSysAlarmVrrpGoMaster
1.3.6.1.4.1.6027.3.26.1.5.1.44 - dellNetSysSnmpIpAclDeny
1.3.6.1.4.1.6027.3.26.1.5.1.22