DATA-DOMAIN-MIB
Data Domain, IncThis MIB is used for managing the suite of Data Domain Products.
snmptranslate -m DATA-DOMAIN-MIB -Tpsnmpwalk -v2c -c <community> -m DATA-DOMAIN-MIB <host> 1.3.6.1.4.1.19746Imports
| IF-MIB | ifDescr, ifIndex |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Counter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IdataDomainMib | 1.3.6.1.4.1.19746 | ||||||||||||||||||||
identity This MIB is used for managing the suite of Data Domain Products. | |||||||||||||||||||||
| NdataDomainMibConformance | 1.3.6.1.4.1.19746.0 | ||||||||||||||||||||
| NdataDomainMibCompliances | 1.3.6.1.4.1.19746.0.1 | ||||||||||||||||||||
| MdataDomainMibCompliance | 1.3.6.1.4.1.19746.0.1.1 | deprecated | |||||||||||||||||||
compliance · deprecated The compliance statement for SNMP entities which implement this MIB module. | |||||||||||||||||||||
| MdataDomainMibComplianceRev1 | 1.3.6.1.4.1.19746.0.1.2 | deprecated | |||||||||||||||||||
compliance · deprecated The compliance statement for SNMP entities which implement this MIB module.
| |||||||||||||||||||||
| MdataDomainMibComplianceRev2 | 1.3.6.1.4.1.19746.0.1.3 | deprecated | |||||||||||||||||||
compliance · deprecated The compliance statement for SNMP entities which implement this MIB module.
| |||||||||||||||||||||
| MdataDomainMibComplianceRev3 | 1.3.6.1.4.1.19746.0.1.4 | deprecated | |||||||||||||||||||
compliance · deprecated The compliance statement for SNMP entities which implement this MIB module.
| |||||||||||||||||||||
| MdataDomainMibComplianceRev4 | 1.3.6.1.4.1.19746.0.1.5 | deprecated | |||||||||||||||||||
compliance · deprecated The compliance statement for SNMP entities which implement this MIB module.
| |||||||||||||||||||||
| MdataDomainMibComplianceRev5 | 1.3.6.1.4.1.19746.0.1.6 | ||||||||||||||||||||
compliance · current The compliance statement for SNMP entities which implement this MIB module.
| |||||||||||||||||||||
| NdataDomainMibGroups | 1.3.6.1.4.1.19746.0.2 | ||||||||||||||||||||
| GenvironmentalsGroup | 1.3.6.1.4.1.19746.0.2.1 | ||||||||||||||||||||
group · current A collection of objects providing environmental monitoring information. | |||||||||||||||||||||
| GnvramGroup | 1.3.6.1.4.1.19746.0.2.2 | ||||||||||||||||||||
group · current A collection of objects providing nvram monitoring information. | |||||||||||||||||||||
| GfileSystemGroup | 1.3.6.1.4.1.19746.0.2.3 | deprecated | |||||||||||||||||||
group · deprecated A collection of objects providing file system monitoring information.
| |||||||||||||||||||||
| GalertsGroup | 1.3.6.1.4.1.19746.0.2.4 | ||||||||||||||||||||
group · current A collection of objects providing alert monitoring information. | |||||||||||||||||||||
| GstatisticsGroup | 1.3.6.1.4.1.19746.0.2.5 | ||||||||||||||||||||
group · current A collection of objects providing statistics information.
| |||||||||||||||||||||
| GinternalDiskStorageGroup | 1.3.6.1.4.1.19746.0.2.7 | ||||||||||||||||||||
group · current A collection of objects providing internal disk monitoring information.
| |||||||||||||||||||||
| GexternalUnmanagedDiskStorageGroup | 1.3.6.1.4.1.19746.0.2.8 | ||||||||||||||||||||
group · current A collection of objects providing external unmanaged disk monitoring information. | |||||||||||||||||||||
| GbasicNotificationsGroup | 1.3.6.1.4.1.19746.0.2.9 | deprecated | |||||||||||||||||||
group · deprecated A collection of objects providing basic notifications.
| |||||||||||||||||||||
| GinternalDiskStorageNotificationsGroup | 1.3.6.1.4.1.19746.0.2.10 | deprecated | |||||||||||||||||||
group · deprecated A collection of objects providing internal disk storage notifications. | |||||||||||||||||||||
| GreplGroup | 1.3.6.1.4.1.19746.0.2.11 | ||||||||||||||||||||
group · current a collection of objects providing replication pair config and monitoring information.
| |||||||||||||||||||||
| GnfsGroup | 1.3.6.1.4.1.19746.0.2.12 | ||||||||||||||||||||
group · current A collection of objects providing NFS monitoring information. | |||||||||||||||||||||
| GcifsGroup | 1.3.6.1.4.1.19746.0.2.13 | deprecated | |||||||||||||||||||
group · deprecated A collection of objects providing CIFS monitoring information.
| |||||||||||||||||||||
| GvtlGroup | 1.3.6.1.4.1.19746.0.2.14 | ||||||||||||||||||||
group · current A collection of objects providing VTL monitoring information.
| |||||||||||||||||||||
| GddboostGroup | 1.3.6.1.4.1.19746.0.2.15 | deprecated | |||||||||||||||||||
group · deprecated A collection of objects providing DDBoost monitoring information.
| |||||||||||||||||||||
| GddsystemGroup | 1.3.6.1.4.1.19746.0.2.16 | deprecated | |||||||||||||||||||
group · deprecated A collection of objects providing system monitoring information.
| |||||||||||||||||||||
| GartGroup | 1.3.6.1.4.1.19746.0.2.17 | ||||||||||||||||||||
group · current A collection of objects providing art monitoring information. | |||||||||||||||||||||
| GmtreeGroup | 1.3.6.1.4.1.19746.0.2.18 | ||||||||||||||||||||
group · current A collection of objects providing mtree monitoring information.
| |||||||||||||||||||||
| GenclosureGroup | 1.3.6.1.4.1.19746.0.2.19 | ||||||||||||||||||||
group · current A collection of objects providing enclousure information. | |||||||||||||||||||||
| GmanagedObjectsGroup | 1.3.6.1.4.1.19746.0.2.20 | ||||||||||||||||||||
group · current A collection of objects providing ddms system information.
| |||||||||||||||||||||
| GnetworkGroup | 1.3.6.1.4.1.19746.0.2.21 | ||||||||||||||||||||
group · current A collection of objects providing network information. | |||||||||||||||||||||
| GfileSystemGroupRev1 | 1.3.6.1.4.1.19746.0.2.22 | ||||||||||||||||||||
group · current A collection of objects providing file system monitoring information.
| |||||||||||||||||||||
| GddsystemGroupRev1 | 1.3.6.1.4.1.19746.0.2.23 | ||||||||||||||||||||
group · current A collection of objects providing system monitoring information.
| |||||||||||||||||||||
| GsmtGroup | 1.3.6.1.4.1.19746.0.2.24 | ||||||||||||||||||||
group · current A collection of objects providing Secure Multi-Tenancy (SMT) information.
| |||||||||||||||||||||
| GquotaGroup | 1.3.6.1.4.1.19746.0.2.25 | ||||||||||||||||||||
group · current A collection of objects providing quota information. | |||||||||||||||||||||
| GddboostGroupRev1 | 1.3.6.1.4.1.19746.0.2.26 | deprecated | |||||||||||||||||||
group · deprecated A collection of objects providing DDBoost monitoring information.
| |||||||||||||||||||||
| GddboostGroupRev2 | 1.3.6.1.4.1.19746.0.2.27 | ||||||||||||||||||||
group · current A collection of objects providing DDBoost monitoring information.
| |||||||||||||||||||||
| GhighAvailabilityGroup | 1.3.6.1.4.1.19746.0.2.28 | ||||||||||||||||||||
group · current A collection of objects providing High Availability information.
| |||||||||||||||||||||
| GscsitargetObjectGroup | 1.3.6.1.4.1.19746.0.2.29 | ||||||||||||||||||||
group · current A collection of objects providing Scsitarget information.
| |||||||||||||||||||||
| GcifsGroupRev1 | 1.3.6.1.4.1.19746.0.2.30 | ||||||||||||||||||||
group · current A collection of objects providing CIFS monitoring information.
| |||||||||||||||||||||
| GgeneratedNotificationsGroup | 1.3.6.1.4.1.19746.0.2.5000 | ||||||||||||||||||||
group · current A collection of objects providing notifications, automatically generated by build.
| |||||||||||||||||||||
| NdataDomainMibObjects | 1.3.6.1.4.1.19746.1 | ||||||||||||||||||||
| Nenvironmentals | 1.3.6.1.4.1.19746.1.1 | ||||||||||||||||||||
| Npower | 1.3.6.1.4.1.19746.1.1.1 | ||||||||||||||||||||
| NpowerModules | 1.3.6.1.4.1.19746.1.1.1.1 | ||||||||||||||||||||
| TpowerModuleTable | 1.3.6.1.4.1.19746.1.1.1.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of PowerModuleEntry. | |||||||||||||||||||||
| RpowerModuleEntry | 1.3.6.1.4.1.19746.1.1.1.1.1.1 | NA | |||||||||||||||||||
row · not-accessible · current powerModuleTable Row Description | |||||||||||||||||||||
| CpowerEnclosureID | 1.3.6.1.4.1.19746.1.1.1.1.1.1.1 | EnclosureID | NA | ||||||||||||||||||
column · EnclosureID · not-accessible · current Power Module Enclosure ID | |||||||||||||||||||||
| CpowerModuleIndex | 1.3.6.1.4.1.19746.1.1.1.1.1.1.2 | PowerModuleIndexTC | NA | ||||||||||||||||||
column · PowerModuleIndexTC · not-accessible · current Power Module index | |||||||||||||||||||||
| CpowerModuleDescription | 1.3.6.1.4.1.19746.1.1.1.1.1.1.3 | PowerModuleDescriptionTC | RO | ||||||||||||||||||
column · PowerModuleDescriptionTC · read-only · current Power Module Description | |||||||||||||||||||||
| CpowerModuleStatus | 1.3.6.1.4.1.19746.1.1.1.1.1.1.4 | PowerModuleStatusTC | RO | ||||||||||||||||||
column · PowerModuleStatusTC · read-only · current current enclosure Power Module status | |||||||||||||||||||||
| Ntemperatures | 1.3.6.1.4.1.19746.1.1.2 | ||||||||||||||||||||
| NtemperatureSensors | 1.3.6.1.4.1.19746.1.1.2.1 | ||||||||||||||||||||
| TtemperatureSensorTable | 1.3.6.1.4.1.19746.1.1.2.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of TemperatureSensorEntry. | |||||||||||||||||||||
| RtemperatureSensorEntry | 1.3.6.1.4.1.19746.1.1.2.1.1.1 | NA | |||||||||||||||||||
row · not-accessible · current temperatureSensorTable Row Description | |||||||||||||||||||||
| CtempEnclosureID | 1.3.6.1.4.1.19746.1.1.2.1.1.1.1 | EnclosureID | NA | ||||||||||||||||||
column · EnclosureID · not-accessible · current Temperature Sensor Enclosure ID | |||||||||||||||||||||
| CtempSensorIndex | 1.3.6.1.4.1.19746.1.1.2.1.1.1.2 | TempSensorIndexTC | NA | ||||||||||||||||||
column · TempSensorIndexTC · not-accessible · current Temperature Sensor Number | |||||||||||||||||||||
| CtempSensorTrapIndex | 1.3.6.1.4.1.19746.1.1.2.1.1.1.3 | TempSensorIndexTC | RO | ||||||||||||||||||
column · TempSensorIndexTC · read-only · current Temperature Sensor Number Used for Traps | |||||||||||||||||||||
| CtempSensorDescription | 1.3.6.1.4.1.19746.1.1.2.1.1.1.4 | TempSensorDescriptionTC | RO | ||||||||||||||||||
column · TempSensorDescriptionTC · read-only · current Temperature Sensor Description | |||||||||||||||||||||
| CtempSensorCurrentValue | 1.3.6.1.4.1.19746.1.1.2.1.1.1.5 | Temperature | RO | ||||||||||||||||||
column · Temperature · read-only · current Current Temperature Value of the sensor | |||||||||||||||||||||
| CtempSensorStatus | 1.3.6.1.4.1.19746.1.1.2.1.1.1.6 | TempSensorStatusTC | RO | ||||||||||||||||||
column · TempSensorStatusTC · read-only · current Current status of the sensor | |||||||||||||||||||||
| Nfans | 1.3.6.1.4.1.19746.1.1.3 | ||||||||||||||||||||
| NfanProperties | 1.3.6.1.4.1.19746.1.1.3.1 | ||||||||||||||||||||
| TfanPropertiesTable | 1.3.6.1.4.1.19746.1.1.3.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of FanPropertiesEntry. | |||||||||||||||||||||
| RfanPropertiesEntry | 1.3.6.1.4.1.19746.1.1.3.1.1.1 | NA | |||||||||||||||||||
| CfanEnclosureID | 1.3.6.1.4.1.19746.1.1.3.1.1.1.1 | EnclosureID | NA | ||||||||||||||||||
column · EnclosureID · not-accessible · current Enclosure ID of fan | |||||||||||||||||||||
| CfanIndex | 1.3.6.1.4.1.19746.1.1.3.1.1.1.2 | FanIndexTC | NA | ||||||||||||||||||
column · FanIndexTC · not-accessible · current Fan Number Index of the fan | |||||||||||||||||||||
| CfanTrapIndex | 1.3.6.1.4.1.19746.1.1.3.1.1.1.3 | FanIndexTC | RO | ||||||||||||||||||
column · FanIndexTC · read-only · current Fan Number trap index, used for trap notifications | |||||||||||||||||||||
| CfanDescription | 1.3.6.1.4.1.19746.1.1.3.1.1.1.4 | FanDescriptionTC | RO | ||||||||||||||||||
column · FanDescriptionTC · read-only · current Vendor supplied description of the fan | |||||||||||||||||||||
| CfanLevel | 1.3.6.1.4.1.19746.1.1.3.1.1.1.5 | FanLevelTC | RO | ||||||||||||||||||
column · FanLevelTC · read-only · current current run level of fan | |||||||||||||||||||||
| CfanStatus | 1.3.6.1.4.1.19746.1.1.3.1.1.1.6 | FanStatusTC | RO | ||||||||||||||||||
column · FanStatusTC · read-only · current Current status of the fan | |||||||||||||||||||||
| Nnvram | 1.3.6.1.4.1.19746.1.2 | ||||||||||||||||||||
| NnvramProperties | 1.3.6.1.4.1.19746.1.2.1 | ||||||||||||||||||||
| TnvramPropertiesTable | 1.3.6.1.4.1.19746.1.2.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of NvramPropertiesEntry. | |||||||||||||||||||||
| RnvramPropertiesEntry | 1.3.6.1.4.1.19746.1.2.1.1.1 | NA | |||||||||||||||||||
| CnvramPropertiesIndex | 1.3.6.1.4.1.19746.1.2.1.1.1.1 | NvramIndexTC | NA | ||||||||||||||||||
column · NvramIndexTC · not-accessible · current NVRAM card index | |||||||||||||||||||||
| CnvramMemorySize | 1.3.6.1.4.1.19746.1.2.1.1.1.2 | NvramMemorySizeTC | RO | ||||||||||||||||||
column · NvramMemorySizeTC · read-only · current Size of NVRAM Memory in bytes | |||||||||||||||||||||
| CnvramWindowSize | 1.3.6.1.4.1.19746.1.2.1.1.1.3 | NvramWindowSizeTC | RO | ||||||||||||||||||
column · NvramWindowSizeTC · read-only · current Window size of NVRAM in bytes | |||||||||||||||||||||
| CnvramHCMemorySize | 1.3.6.1.4.1.19746.1.2.1.1.1.4 | NvramHCPropertyBytesTC | RO | ||||||||||||||||||
column · NvramHCPropertyBytesTC · read-only · current The size of an NVRAM entity's memory in bytes, with support for high capacity modules. This entry may be used in place of nvramMemorySize. | |||||||||||||||||||||
| NnvramStats | 1.3.6.1.4.1.19746.1.2.2 | ||||||||||||||||||||
| TnvramStatsTable | 1.3.6.1.4.1.19746.1.2.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of NvramStatsEntry. | |||||||||||||||||||||
| RnvramStatsEntry | 1.3.6.1.4.1.19746.1.2.2.1.1 | NA | |||||||||||||||||||
| CnvramStatsIndex | 1.3.6.1.4.1.19746.1.2.2.1.1.1 | NvramIndexTC | NA | ||||||||||||||||||
column · NvramIndexTC · not-accessible · current NVRAM card index | |||||||||||||||||||||
| CnvramPCIErrorCount | 1.3.6.1.4.1.19746.1.2.2.1.1.2 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of PCI Errors Encountered on NVRAM Card | |||||||||||||||||||||
| CnvramMemoryErrorCount | 1.3.6.1.4.1.19746.1.2.2.1.1.3 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of Memory Errors Encountered on NVRAM Card | |||||||||||||||||||||
| NnvramBatteries | 1.3.6.1.4.1.19746.1.2.3 | ||||||||||||||||||||
| TnvramBatteryTable | 1.3.6.1.4.1.19746.1.2.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of NvramBatteryEntry. | |||||||||||||||||||||
| RnvramBatteryEntry | 1.3.6.1.4.1.19746.1.2.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current nvramBatteryTable Row Description | |||||||||||||||||||||
| CnvramBatteriesIndex | 1.3.6.1.4.1.19746.1.2.3.1.1.1 | NvramIndexTC | NA | ||||||||||||||||||
column · NvramIndexTC · not-accessible · current NVRAM card index | |||||||||||||||||||||
| CnvramBatteryIndex | 1.3.6.1.4.1.19746.1.2.3.1.1.2 | NvramBatteryIndexTC | NA | ||||||||||||||||||
column · NvramBatteryIndexTC · not-accessible · current NVRAM Battery Number | |||||||||||||||||||||
| CnvramBatteryStatus | 1.3.6.1.4.1.19746.1.2.3.1.1.3 | NvramBatteryStatusTC | RO | ||||||||||||||||||
column · NvramBatteryStatusTC · read-only · current NVRAM Battery Status | |||||||||||||||||||||
| CnvramBatteryCharge | 1.3.6.1.4.1.19746.1.2.3.1.1.4 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current NVRAM Battery charge percentage | |||||||||||||||||||||
| NfileSystem | 1.3.6.1.4.1.19746.1.3 | ||||||||||||||||||||
| NfileSystemProperties | 1.3.6.1.4.1.19746.1.3.1 | ||||||||||||||||||||
| SfileSystemStatus | 1.3.6.1.4.1.19746.1.3.1.1 | FileSystemStatusTC | RO | ||||||||||||||||||
scalar · FileSystemStatusTC · read-only · current Status of the file system | |||||||||||||||||||||
| SfileSystemVirtualSpace | 1.3.6.1.4.1.19746.1.3.1.2 | FileSystemSpaceUnitTC | RO | ||||||||||||||||||
scalar · FileSystemSpaceUnitTC · read-only · current Amount of Uncompressed data that has been backed up by the system | |||||||||||||||||||||
| SfileSystemUpTime | 1.3.6.1.4.1.19746.1.3.1.3 | DDMibTimeStampTC | RO | ||||||||||||||||||
scalar · DDMibTimeStampTC · read-only · current File System Up time | |||||||||||||||||||||
| SfileSystemStatusMessage | 1.3.6.1.4.1.19746.1.3.1.4 | DDMibTableString256TC | RO | ||||||||||||||||||
scalar · DDMibTableString256TC · read-only · current file system status message | |||||||||||||||||||||
| NfileSystemSpace | 1.3.6.1.4.1.19746.1.3.2 | ||||||||||||||||||||
| TfileSystemSpaceTable | 1.3.6.1.4.1.19746.1.3.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of FileSystemSpaceEntry. | |||||||||||||||||||||
| RfileSystemSpaceEntry | 1.3.6.1.4.1.19746.1.3.2.1.1 | NA | |||||||||||||||||||
| CfileSystemResourceIndex | 1.3.6.1.4.1.19746.1.3.2.1.1.1 | FileSystemResourceIndexTC | NA | 1 | |||||||||||||||||
column · FileSystemResourceIndexTC · not-accessible · current File system resource index Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemResourceTrapIndex | 1.3.6.1.4.1.19746.1.3.2.1.1.2 | FileSystemResourceIndexTC | RO | 1 | |||||||||||||||||
column · FileSystemResourceIndexTC · read-only · current File system resource trap index Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemResourceName | 1.3.6.1.4.1.19746.1.3.2.1.1.3 | FileSystemResourceNameTC | RO | /ddvar | |||||||||||||||||
column · FileSystemResourceNameTC · read-only · current File system resource name Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemSpaceSize | 1.3.6.1.4.1.19746.1.3.2.1.1.4 | FileSystemSpaceUnitTC | RO | 132.9 | |||||||||||||||||
column · FileSystemSpaceUnitTC · read-only · current Size of the file system resource in gigabytes Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemSpaceUsed | 1.3.6.1.4.1.19746.1.3.2.1.1.5 | FileSystemSpaceUnitTC | RO | 11.7 | |||||||||||||||||
column · FileSystemSpaceUnitTC · read-only · current Amount of used space within the file system resource in gigabytes Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemSpaceAvail | 1.3.6.1.4.1.19746.1.3.2.1.1.6 | FileSystemSpaceUnitTC | RO | 114.4 | |||||||||||||||||
column · FileSystemSpaceUnitTC · read-only · current Amount of available space within the file system resource in gigabytes Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemPercentUsed | 1.3.6.1.4.1.19746.1.3.2.1.1.7 | Percentage | RO | 9 | |||||||||||||||||
column · Percentage · read-only · current Percentage of used space within the file system resource Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemSpaceCleanable | 1.3.6.1.4.1.19746.1.3.2.1.1.8 | FileSystemSpaceUnitTC | RO | 0.0 | |||||||||||||||||
column · FileSystemSpaceUnitTC · read-only · current Amount of cleanable space within the file system resource Example values from LibreNMS test devices
| |||||||||||||||||||||
| CfileSystemResourceTier | 1.3.6.1.4.1.19746.1.3.2.1.1.9 | DDMibTableString128TC | RO | Active Tier | |||||||||||||||||
column · DDMibTableString128TC · read-only · current The tier that a resource belongs to, such as active or archive. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NfileSystemCompression | 1.3.6.1.4.1.19746.1.3.3 | ||||||||||||||||||||
| TfileSystemCompressionTable | 1.3.6.1.4.1.19746.1.3.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of FileSystemCompressionEntry. | |||||||||||||||||||||
| RfileSystemCompressionEntry | 1.3.6.1.4.1.19746.1.3.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current fileSystemCompressionTable Row Description | |||||||||||||||||||||
| CfileSystemCompressionIndex | 1.3.6.1.4.1.19746.1.3.3.1.1.1 | FileSystemResourceIndexTC | NA | ||||||||||||||||||
column · FileSystemResourceIndexTC · not-accessible · current File system compression index | |||||||||||||||||||||
| CfileSystemCompressionPeriod | 1.3.6.1.4.1.19746.1.3.3.1.1.2 | FileSystemCompressionPeriodTC | RO | ||||||||||||||||||
column · FileSystemCompressionPeriodTC · read-only · current File system compression period | |||||||||||||||||||||
| CfileSystemCompressionStartTime | 1.3.6.1.4.1.19746.1.3.3.1.1.3 | DateTC | RO | ||||||||||||||||||
column · DateTC · read-only · current File system compression start time | |||||||||||||||||||||
| CfileSystemCompressionEndTime | 1.3.6.1.4.1.19746.1.3.3.1.1.4 | DateTC | RO | ||||||||||||||||||
column · DateTC · read-only · current File system compression end time | |||||||||||||||||||||
| CfileSystemPreCompressionSize | 1.3.6.1.4.1.19746.1.3.3.1.1.5 | FileSystemCompressionSizeTC | RO | ||||||||||||||||||
column · FileSystemCompressionSizeTC · read-only · current Size of the file system pre compression in gigabytes | |||||||||||||||||||||
| CfileSystemPostCompressionSize | 1.3.6.1.4.1.19746.1.3.3.1.1.6 | FileSystemCompressionSizeTC | RO | ||||||||||||||||||
column · FileSystemCompressionSizeTC · read-only · current Size of the file system post compression in gigabytes | |||||||||||||||||||||
| CfileSystemGlobalCompressionFactor | 1.3.6.1.4.1.19746.1.3.3.1.1.7 | FileSystemCompressionFactorTC | RO | ||||||||||||||||||
column · FileSystemCompressionFactorTC · read-only · current File system global compression factor | |||||||||||||||||||||
| CfileSystemLocalCompressionFactor | 1.3.6.1.4.1.19746.1.3.3.1.1.8 | FileSystemCompressionFactorTC | RO | ||||||||||||||||||
column · FileSystemCompressionFactorTC · read-only · current File system local compression factor | |||||||||||||||||||||
| CfileSystemTotalCompressionFactor | 1.3.6.1.4.1.19746.1.3.3.1.1.9 | FileSystemCompressionFactorTC | RO | ||||||||||||||||||
column · FileSystemCompressionFactorTC · read-only · current File system Total compression factor | |||||||||||||||||||||
| CfileSystemReductionPercent | 1.3.6.1.4.1.19746.1.3.3.1.1.10 | Percentage | RO | deprecated | |||||||||||||||||
column · Percentage · read-only · deprecated File system Reduction Percent | |||||||||||||||||||||
| CfileSystemReductionPercent1 | 1.3.6.1.4.1.19746.1.3.3.1.1.11 | PercentageStr | RO | ||||||||||||||||||
column · PercentageStr · read-only · current File system Reduction Percent | |||||||||||||||||||||
| NfileSystemOptions | 1.3.6.1.4.1.19746.1.3.4 | ||||||||||||||||||||
| TfileSystemOptionsTable | 1.3.6.1.4.1.19746.1.3.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of fileSystemOptionsEntry. | |||||||||||||||||||||
| RfileSystemOptionsEntry | 1.3.6.1.4.1.19746.1.3.4.1.1 | NA | |||||||||||||||||||
| CfileSystemOptionsIndex | 1.3.6.1.4.1.19746.1.3.4.1.1.1 | FileSystemOptionsIndexTC | NA | ||||||||||||||||||
column · FileSystemOptionsIndexTC · not-accessible · current fileSystem Options index | |||||||||||||||||||||
| CfileSystemOptionsName | 1.3.6.1.4.1.19746.1.3.4.1.1.2 | FileSystemOptionsNameTC | RO | ||||||||||||||||||
column · FileSystemOptionsNameTC · read-only · current This object represents the fileSystem Options type in text format.
Below lists the possible options and their representations.
-------------------------------- --------------------------
Option Name Representation in text
-------------------------------- --------------------------
Local compression type gz/gzfast/lz
Marker-type auto/cv1
Report-replica-as-writable enabled/disabled
Low-bw-optim replication support enabled/disabled
Current global compression type 1/9
Staging reserve % of the total space/disabled
Staging clean % of staging reserve space
Staging delete suspend % of staging reserve space
-------------------------------- --------------------------- | |||||||||||||||||||||
| CfileSystemOptionsValue | 1.3.6.1.4.1.19746.1.3.4.1.1.3 | FileSystemOptionsValueTC | RO | ||||||||||||||||||
column · FileSystemOptionsValueTC · read-only · current fileSystem Options Value | |||||||||||||||||||||
| NfileSystemClean | 1.3.6.1.4.1.19746.1.3.5 | ||||||||||||||||||||
| TfileSystemCleanTable | 1.3.6.1.4.1.19746.1.3.5.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of fileSystemCleanEntry. | |||||||||||||||||||||
| RfileSystemCleanEntry | 1.3.6.1.4.1.19746.1.3.5.1.1 | NA | |||||||||||||||||||
| CfileSystemCleanIndex | 1.3.6.1.4.1.19746.1.3.5.1.1.1 | FileSystemCleanIndexTC | NA | ||||||||||||||||||
column · FileSystemCleanIndexTC · not-accessible · current fileSystem Clean index | |||||||||||||||||||||
| CfileSystemCleanStatus | 1.3.6.1.4.1.19746.1.3.5.1.1.2 | FileSystemCleanStatusTC | RO | ||||||||||||||||||
column · FileSystemCleanStatusTC · read-only · current fileSystem Clean Status | |||||||||||||||||||||
| CfileSystemCleanSchedule | 1.3.6.1.4.1.19746.1.3.5.1.1.3 | FileSystemCleanScheduleTC | RO | ||||||||||||||||||
column · FileSystemCleanScheduleTC · read-only · current fileSystem Clean Schedule | |||||||||||||||||||||
| CfileSystemCleanThrottle | 1.3.6.1.4.1.19746.1.3.5.1.1.4 | FileSystemCleanThrottleTC | RO | ||||||||||||||||||
column · FileSystemCleanThrottleTC · read-only · current fileSystem Clean Throttle | |||||||||||||||||||||
| NfileSystemArchiveUnit | 1.3.6.1.4.1.19746.1.3.6 | ||||||||||||||||||||
| TfileSystemArchiveUnitTable | 1.3.6.1.4.1.19746.1.3.6.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of fileSystemArchiveUnitEntry. | |||||||||||||||||||||
| RfileSystemArchiveUnitEntry | 1.3.6.1.4.1.19746.1.3.6.1.1 | NA | |||||||||||||||||||
row · not-accessible · current fileSystemArchiveUnitTable Row Description | |||||||||||||||||||||
| CfileSystemArchiveUnitIndex | 1.3.6.1.4.1.19746.1.3.6.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current fileSystem ArchiveUnit index | |||||||||||||||||||||
| CfileSystemArchiveUnitName | 1.3.6.1.4.1.19746.1.3.6.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current fileSystem ArchiveUnit Name | |||||||||||||||||||||
| CfileSystemArchiveUnitState | 1.3.6.1.4.1.19746.1.3.6.1.1.3 | FileSystemArchiveUnitStateTC | RO | ||||||||||||||||||
column · FileSystemArchiveUnitStateTC · read-only · current fileSystem ArchiveUnit State | |||||||||||||||||||||
| CfileSystemArchiveUnitStatus | 1.3.6.1.4.1.19746.1.3.6.1.1.4 | FileSystemArchiveUnitStatusTC | RO | ||||||||||||||||||
column · FileSystemArchiveUnitStatusTC · read-only · current fileSystem ArchiveUnit Status | |||||||||||||||||||||
| CfileSystemArchiveUnitStartTime | 1.3.6.1.4.1.19746.1.3.6.1.1.5 | DDMibTimeStampTC | RO | ||||||||||||||||||
column · DDMibTimeStampTC · read-only · current fileSystem ArchiveUnit start Time | |||||||||||||||||||||
| CfileSystemArchiveUnitEndTime | 1.3.6.1.4.1.19746.1.3.6.1.1.6 | DDMibTimeStampTC | RO | ||||||||||||||||||
column · DDMibTimeStampTC · read-only · current fileSystem ArchiveUnit End Time | |||||||||||||||||||||
| CfileSystemArchiveUnitSize | 1.3.6.1.4.1.19746.1.3.6.1.1.7 | DDMibTableSizeGibTC | RO | ||||||||||||||||||
column · DDMibTableSizeGibTC · read-only · current fileSystem ArchiveUnit Size in Gib | |||||||||||||||||||||
| CfileSystemArchiveUnitDiskGroups | 1.3.6.1.4.1.19746.1.3.6.1.1.8 | DDMibTableString1024TC | RO | ||||||||||||||||||
column · DDMibTableString1024TC · read-only · current fileSystem ArchiveUnit DiskGroups | |||||||||||||||||||||
| Nalerts | 1.3.6.1.4.1.19746.1.4 | ||||||||||||||||||||
| NcurrentAlerts | 1.3.6.1.4.1.19746.1.4.1 | ||||||||||||||||||||
| TcurrentAlertTable | 1.3.6.1.4.1.19746.1.4.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of CurrentAlertEntry. | |||||||||||||||||||||
| RcurrentAlertEntry | 1.3.6.1.4.1.19746.1.4.1.1.1 | NA | |||||||||||||||||||
| CcurrentAlertIndex | 1.3.6.1.4.1.19746.1.4.1.1.1.1 | AlertIndexTC | NA | ||||||||||||||||||
column · AlertIndexTC · not-accessible · current Current Alert Row index | |||||||||||||||||||||
| CcurrentAlertTimestamp | 1.3.6.1.4.1.19746.1.4.1.1.1.2 | AlertTimestampTC | RO | ||||||||||||||||||
column · AlertTimestampTC · read-only · current Timestamp of current alert | |||||||||||||||||||||
| CcurrentAlertDescription | 1.3.6.1.4.1.19746.1.4.1.1.1.3 | AlertDescriptionTC | RO | ||||||||||||||||||
column · AlertDescriptionTC · read-only · current Alert Description | |||||||||||||||||||||
| CcurrentAlertSeverity | 1.3.6.1.4.1.19746.1.4.1.1.1.4 | DDMibAlertSeverityTC | RO | ||||||||||||||||||
column · DDMibAlertSeverityTC · read-only · current Alert Severity | |||||||||||||||||||||
| CcurrentAlertID | 1.3.6.1.4.1.19746.1.4.1.1.1.5 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current Alert ID | |||||||||||||||||||||
| NalertHistory | 1.3.6.1.4.1.19746.1.4.2 | ||||||||||||||||||||
| TalertHistoryTable | 1.3.6.1.4.1.19746.1.4.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of Alert History Entries. | |||||||||||||||||||||
| RalertHistoryEntry | 1.3.6.1.4.1.19746.1.4.2.1.1 | NA | |||||||||||||||||||
| CalertHistoryIndex | 1.3.6.1.4.1.19746.1.4.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Alert History Row index | |||||||||||||||||||||
| CalertHistoryTimestamp | 1.3.6.1.4.1.19746.1.4.2.1.1.2 | DDMibTimeStampTC | RO | ||||||||||||||||||
column · DDMibTimeStampTC · read-only · current Timestamp of alert | |||||||||||||||||||||
| CalertHistoryDescription | 1.3.6.1.4.1.19746.1.4.2.1.1.3 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current Alert history Description | |||||||||||||||||||||
| CalertHistorySeverity | 1.3.6.1.4.1.19746.1.4.2.1.1.4 | DDMibAlertSeverityTC | RO | ||||||||||||||||||
column · DDMibAlertSeverityTC · read-only · current Alert history Severity | |||||||||||||||||||||
| CalertHistoryStatus | 1.3.6.1.4.1.19746.1.4.2.1.1.5 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Alert history Status (Post or Cleared) | |||||||||||||||||||||
| NalertInfo | 1.3.6.1.4.1.19746.1.4.3 | ||||||||||||||||||||
| TalertInfoTable | 1.3.6.1.4.1.19746.1.4.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of Alert Information. | |||||||||||||||||||||
| RalertInfoEntry | 1.3.6.1.4.1.19746.1.4.3.1.1 | NA | |||||||||||||||||||
| CalertInfoIndex | 1.3.6.1.4.1.19746.1.4.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Alert Info Row index | |||||||||||||||||||||
| CalertInfoDescription | 1.3.6.1.4.1.19746.1.4.3.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current Alert Info Description | |||||||||||||||||||||
| Nstatistics | 1.3.6.1.4.1.19746.1.5 | ||||||||||||||||||||
| NsystemStats | 1.3.6.1.4.1.19746.1.5.1 | ||||||||||||||||||||
| TsystemStatsTable | 1.3.6.1.4.1.19746.1.5.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of SystemStatsEntry. | |||||||||||||||||||||
| RsystemStatsEntry | 1.3.6.1.4.1.19746.1.5.1.1.1 | NA | |||||||||||||||||||
| CsystemStatsIndex | 1.3.6.1.4.1.19746.1.5.1.1.1.1 | SystemStatsIndexTC | NA | ||||||||||||||||||
column · SystemStatsIndexTC · not-accessible · current System Stats Row index | |||||||||||||||||||||
| CcpuAvgPercentageBusy | 1.3.6.1.4.1.19746.1.5.1.1.1.2 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current CPU Average Percentage Busy | |||||||||||||||||||||
| CcpuMaxPercentageBusy | 1.3.6.1.4.1.19746.1.5.1.1.1.3 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current CPU Max Percentage Busy | |||||||||||||||||||||
| CnfsOpsPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.4 | OpsPerSecond | RO | ||||||||||||||||||
column · OpsPerSecond · read-only · current Number of NFS Operations performed per second | |||||||||||||||||||||
| CnfsIdlePercentage | 1.3.6.1.4.1.19746.1.5.1.1.1.5 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current Percentage of time NFS was Idle | |||||||||||||||||||||
| CnfsProcPercentage | 1.3.6.1.4.1.19746.1.5.1.1.1.6 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current Percentage of time NFS was processing | |||||||||||||||||||||
| CnfsSendPercentage | 1.3.6.1.4.1.19746.1.5.1.1.1.7 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current Percentage of time NFS was sending requests | |||||||||||||||||||||
| CnfsReceivePercentage | 1.3.6.1.4.1.19746.1.5.1.1.1.8 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current Percentage of time NFS was receiving requests | |||||||||||||||||||||
| CcifsOpsPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.9 | OpsPerSecond | RO | ||||||||||||||||||
column · OpsPerSecond · read-only · current Number of CIFS Operations performed per second | |||||||||||||||||||||
| CdiskReadKBytesPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.10 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of KBytes per second read from disk | |||||||||||||||||||||
| CdiskWriteKBytesPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.11 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of KBytes per second written on disk | |||||||||||||||||||||
| CdiskBusyPercentage | 1.3.6.1.4.1.19746.1.5.1.1.1.12 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current Percentage of Time Disks were busy | |||||||||||||||||||||
| CnvramReadKBytesPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.13 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of KBytes read per second from NVRAM | |||||||||||||||||||||
| CnvramWriteKBytesPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.14 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of KBytes written per second on NVRAM | |||||||||||||||||||||
| CreplInKBytesPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.15 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of KBytes per second received for Replication | |||||||||||||||||||||
| CreplOutKBytesPerSecond | 1.3.6.1.4.1.19746.1.5.1.1.1.16 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of KBytes per second sent for Replication | |||||||||||||||||||||
| NdiskStorage | 1.3.6.1.4.1.19746.1.6 | ||||||||||||||||||||
| NdiskProperties | 1.3.6.1.4.1.19746.1.6.1 | ||||||||||||||||||||
| TdiskPropertiesTable | 1.3.6.1.4.1.19746.1.6.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of DiskPropertiesEntry. | |||||||||||||||||||||
| RdiskPropertiesEntry | 1.3.6.1.4.1.19746.1.6.1.1.1 | NA | |||||||||||||||||||
row · not-accessible · current diskPropertiesTable Row Description | |||||||||||||||||||||
| CdiskPropEnclosureID | 1.3.6.1.4.1.19746.1.6.1.1.1.1 | EnclosureID | NA | ||||||||||||||||||
column · EnclosureID · not-accessible · current Enclosure ID of disk | |||||||||||||||||||||
| CdiskPropIndex | 1.3.6.1.4.1.19746.1.6.1.1.1.2 | DiskIndexTC | NA | ||||||||||||||||||
column · DiskIndexTC · not-accessible · current Disk Number | |||||||||||||||||||||
| CdiskPropTrapIndex | 1.3.6.1.4.1.19746.1.6.1.1.1.3 | DiskIndexTC | RO | ||||||||||||||||||
column · DiskIndexTC · read-only · current Disk Number for Traps | |||||||||||||||||||||
| CdiskModel | 1.3.6.1.4.1.19746.1.6.1.1.1.4 | DiskModelTC | RO | ||||||||||||||||||
column · DiskModelTC · read-only · current Manufacture and model of the disk | |||||||||||||||||||||
| CdiskFirmwareVersion | 1.3.6.1.4.1.19746.1.6.1.1.1.5 | DiskFirmwareVersionTC | RO | ||||||||||||||||||
column · DiskFirmwareVersionTC · read-only · current Firmware version of the disk | |||||||||||||||||||||
| CdiskSerialNumber | 1.3.6.1.4.1.19746.1.6.1.1.1.6 | DiskSerialNumberTC | RO | ||||||||||||||||||
column · DiskSerialNumberTC · read-only · current Serial Number of the disk | |||||||||||||||||||||
| CdiskCapacity | 1.3.6.1.4.1.19746.1.6.1.1.1.7 | DiskCapacityTC | RO | ||||||||||||||||||
column · DiskCapacityTC · read-only · current Capacity of the disk | |||||||||||||||||||||
| CdiskPropState | 1.3.6.1.4.1.19746.1.6.1.1.1.8 | DiskStateTC | RO | ||||||||||||||||||
column · DiskStateTC · read-only · current Current State of the disk | |||||||||||||||||||||
| CdiskPack | 1.3.6.1.4.1.19746.1.6.1.1.1.9 | DiskPackTC | RO | ||||||||||||||||||
column · DiskPackTC · read-only · current Pack information of the disk. Applicable to enclosures with packs such as ES60, and not for ES20 or ES30. | |||||||||||||||||||||
| NdiskPerformance | 1.3.6.1.4.1.19746.1.6.2 | ||||||||||||||||||||
| TdiskPerformanceTable | 1.3.6.1.4.1.19746.1.6.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of DiskPerformanceEntry. | |||||||||||||||||||||
| RdiskPerformanceEntry | 1.3.6.1.4.1.19746.1.6.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current diskPerformanceTable Row Description | |||||||||||||||||||||
| CdiskPerfEnclosureID | 1.3.6.1.4.1.19746.1.6.2.1.1.1 | EnclosureID | NA | ||||||||||||||||||
column · EnclosureID · not-accessible · current Enclosure ID of disk | |||||||||||||||||||||
| CdiskPerfIndex | 1.3.6.1.4.1.19746.1.6.2.1.1.2 | DiskIndexTC | NA | ||||||||||||||||||
column · DiskIndexTC · not-accessible · current Disk Number | |||||||||||||||||||||
| CdiskSectorsRead | 1.3.6.1.4.1.19746.1.6.2.1.1.3 | DiskSectorsPerSecondTC | RO | ||||||||||||||||||
column · DiskSectorsPerSecondTC · read-only · current Number of disk sectors read per second | |||||||||||||||||||||
| CdiskSectorsWritten | 1.3.6.1.4.1.19746.1.6.2.1.1.4 | DiskSectorsPerSecondTC | RO | ||||||||||||||||||
column · DiskSectorsPerSecondTC · read-only · current Number of disk sectors written per second | |||||||||||||||||||||
| CdiskTotalKBytes | 1.3.6.1.4.1.19746.1.6.2.1.1.5 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Total Number of Kilo-bytes read/written per second | |||||||||||||||||||||
| CdiskBusy | 1.3.6.1.4.1.19746.1.6.2.1.1.6 | Percentage | RO | ||||||||||||||||||
column · Percentage · read-only · current Percentage of time disk is busy | |||||||||||||||||||||
| CdiskPerfState | 1.3.6.1.4.1.19746.1.6.2.1.1.7 | DiskStateTC | RO | ||||||||||||||||||
column · DiskStateTC · read-only · current Current State of the disk | |||||||||||||||||||||
| NdiskReliability | 1.3.6.1.4.1.19746.1.6.3 | ||||||||||||||||||||
| TdiskReliabilityTable | 1.3.6.1.4.1.19746.1.6.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of DiskReliabilityEntry. | |||||||||||||||||||||
| RdiskReliabilityEntry | 1.3.6.1.4.1.19746.1.6.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current diskReliabilityTable Row Description | |||||||||||||||||||||
| CdiskErrEnclosureID | 1.3.6.1.4.1.19746.1.6.3.1.1.1 | EnclosureID | NA | ||||||||||||||||||
column · EnclosureID · not-accessible · current Enclosure ID of disk | |||||||||||||||||||||
| CdiskErrIndex | 1.3.6.1.4.1.19746.1.6.3.1.1.2 | DiskIndexTC | NA | ||||||||||||||||||
column · DiskIndexTC · not-accessible · current Disk Number | |||||||||||||||||||||
| CdiskErrTrapIndex | 1.3.6.1.4.1.19746.1.6.3.1.1.3 | DiskIndexTC | RO | ||||||||||||||||||
column · DiskIndexTC · read-only · current Disk Number for Traps | |||||||||||||||||||||
| CdiskTemperature | 1.3.6.1.4.1.19746.1.6.3.1.1.4 | Temperature | RO | ||||||||||||||||||
column · Temperature · read-only · current Current Disk Temperature in Celsius | |||||||||||||||||||||
| CdiskTimeoutCount | 1.3.6.1.4.1.19746.1.6.3.1.1.5 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of command timeouts | |||||||||||||||||||||
| CdiskReadFailCount | 1.3.6.1.4.1.19746.1.6.3.1.1.6 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of read failures | |||||||||||||||||||||
| CdiskWriteFailCount | 1.3.6.1.4.1.19746.1.6.3.1.1.7 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of write failures | |||||||||||||||||||||
| CdiskMiscFailCount | 1.3.6.1.4.1.19746.1.6.3.1.1.8 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of miscellaneous failures | |||||||||||||||||||||
| CdiskOffTrackErrCount | 1.3.6.1.4.1.19746.1.6.3.1.1.9 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of offtrack errors | |||||||||||||||||||||
| CdiskSoftEccCount | 1.3.6.1.4.1.19746.1.6.3.1.1.10 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of soft ecc errors | |||||||||||||||||||||
| CdiskCrcErrCount | 1.3.6.1.4.1.19746.1.6.3.1.1.11 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of crc errors | |||||||||||||||||||||
| CdiskProbationalCount | 1.3.6.1.4.1.19746.1.6.3.1.1.12 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of probational errors | |||||||||||||||||||||
| CdiskReallocCount | 1.3.6.1.4.1.19746.1.6.3.1.1.13 | ErrorCount | RO | ||||||||||||||||||
column · ErrorCount · read-only · current Number of reallocation errors | |||||||||||||||||||||
| CdiskErrState | 1.3.6.1.4.1.19746.1.6.3.1.1.14 | DiskStateTC | RO | ||||||||||||||||||
column · DiskStateTC · read-only · current Current State of the disk | |||||||||||||||||||||
| Nreplication | 1.3.6.1.4.1.19746.1.8 | ||||||||||||||||||||
| NreplicationInfo | 1.3.6.1.4.1.19746.1.8.1 | ||||||||||||||||||||
| TreplicationInfoTable | 1.3.6.1.4.1.19746.1.8.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of ReplicationInfoEntry. | |||||||||||||||||||||
| RreplicationInfoEntry | 1.3.6.1.4.1.19746.1.8.1.1.1 | NA | |||||||||||||||||||
| CreplContext | 1.3.6.1.4.1.19746.1.8.1.1.1.1 | ReplicationContextTC | NA | ||||||||||||||||||
column · ReplicationContextTC · not-accessible · current context ID of replication source/dest pair | |||||||||||||||||||||
| CreplTrapContext | 1.3.6.1.4.1.19746.1.8.1.1.1.2 | ReplicationContextTC | RO | ||||||||||||||||||
column · ReplicationContextTC · read-only · current context ID of replication source/dest pair for traps | |||||||||||||||||||||
| CreplState | 1.3.6.1.4.1.19746.1.8.1.1.1.3 | ReplicationStateTC | RO | ||||||||||||||||||
column · ReplicationStateTC · read-only · current state of replication source/dest pair | |||||||||||||||||||||
| CreplStatus | 1.3.6.1.4.1.19746.1.8.1.1.1.4 | ReplicationStatusTC | RO | ||||||||||||||||||
column · ReplicationStatusTC · read-only · current status of replication source/dest pair connection | |||||||||||||||||||||
| CreplFileSysStatus | 1.3.6.1.4.1.19746.1.8.1.1.1.5 | FileSystemStatusTC | RO | ||||||||||||||||||
column · FileSystemStatusTC · read-only · current status of filesystem | |||||||||||||||||||||
| CreplConnTime | 1.3.6.1.4.1.19746.1.8.1.1.1.6 | ReplicationConnectTimeTC | RO | ||||||||||||||||||
column · ReplicationConnectTimeTC · read-only · current time of connection established between source and dest, or time since disconnect if status is 'disconnected' | |||||||||||||||||||||
| CreplSource | 1.3.6.1.4.1.19746.1.8.1.1.1.7 | ReplicationPathTC | RO | ||||||||||||||||||
column · ReplicationPathTC · read-only · current network path to replication source directory | |||||||||||||||||||||
| CreplDestination | 1.3.6.1.4.1.19746.1.8.1.1.1.8 | ReplicationPathTC | RO | ||||||||||||||||||
column · ReplicationPathTC · read-only · current network path to replication destination directory | |||||||||||||||||||||
| CreplPreCompBytesSent | 1.3.6.1.4.1.19746.1.8.1.1.1.9 | ReplicationTrafficTC | RO | ||||||||||||||||||
column · ReplicationTrafficTC · read-only · current pre compression bytes sent | |||||||||||||||||||||
| CreplPostCompBytesSent | 1.3.6.1.4.1.19746.1.8.1.1.1.10 | ReplicationTrafficTC | RO | ||||||||||||||||||
column · ReplicationTrafficTC · read-only · current post compression bytes sent | |||||||||||||||||||||
| CreplPreCompBytesRemaining | 1.3.6.1.4.1.19746.1.8.1.1.1.11 | ReplicationTrafficTC | RO | ||||||||||||||||||
column · ReplicationTrafficTC · read-only · current pre compression bytes remaining | |||||||||||||||||||||
| CreplPostCompBytesReceived | 1.3.6.1.4.1.19746.1.8.1.1.1.12 | ReplicationTrafficTC | RO | ||||||||||||||||||
column · ReplicationTrafficTC · read-only · current post compression bytes received | |||||||||||||||||||||
| CreplThrottle | 1.3.6.1.4.1.19746.1.8.1.1.1.13 | ReplicationThrottleTC | RO | ||||||||||||||||||
column · ReplicationThrottleTC · read-only · current replication throttle in bps -- -1 is disabled, 0 unlimited | |||||||||||||||||||||
| CreplSyncedAsOfTime | 1.3.6.1.4.1.19746.1.8.1.1.1.14 | ReplicationSyncedTimeTC | RO | ||||||||||||||||||
column · ReplicationSyncedTimeTC · read-only · current time when the source and destination were in sync, or 0 if the time is unknown | |||||||||||||||||||||
| NreplicationConfig | 1.3.6.1.4.1.19746.1.8.2 | ||||||||||||||||||||
| TreplicationConfigTable | 1.3.6.1.4.1.19746.1.8.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of ReplicationConfigEntry. | |||||||||||||||||||||
| RreplicationConfigEntry | 1.3.6.1.4.1.19746.1.8.2.1.1 | NA | |||||||||||||||||||
| CreplConfigIndex | 1.3.6.1.4.1.19746.1.8.2.1.1.1 | ReplicationConfigIndexTC | NA | ||||||||||||||||||
column · ReplicationConfigIndexTC · not-accessible · current ConfigIndex ID of replication source/dest pair | |||||||||||||||||||||
| CreplConfigContextId | 1.3.6.1.4.1.19746.1.8.2.1.1.2 | ReplicationConfigContextIdTC | RO | ||||||||||||||||||
column · ReplicationConfigContextIdTC · read-only · current ConfigContextId of replication source/dest pair | |||||||||||||||||||||
| CreplConfigSource | 1.3.6.1.4.1.19746.1.8.2.1.1.3 | ReplicationConfigSourceTC | RO | ||||||||||||||||||
column · ReplicationConfigSourceTC · read-only · current Source for replication source/dest pair connection | |||||||||||||||||||||
| CreplConfigDest | 1.3.6.1.4.1.19746.1.8.2.1.1.4 | ReplicationConfigDestTC | RO | ||||||||||||||||||
column · ReplicationConfigDestTC · read-only · current Destination for replication connection | |||||||||||||||||||||
| CreplConfigConnHost | 1.3.6.1.4.1.19746.1.8.2.1.1.5 | ReplicationConfigConnHostTC | RO | ||||||||||||||||||
column · ReplicationConfigConnHostTC · read-only · current Host for a replication connection | |||||||||||||||||||||
| CreplConfigConnPort | 1.3.6.1.4.1.19746.1.8.2.1.1.6 | ReplicationConfigConnPortTC | RO | ||||||||||||||||||
column · ReplicationConfigConnPortTC · read-only · current Replication Configuration port for the connection | |||||||||||||||||||||
| CreplConfigLowBWOptim | 1.3.6.1.4.1.19746.1.8.2.1.1.7 | ReplicationConfigLowBWOptimTC | RO | ||||||||||||||||||
column · ReplicationConfigLowBWOptimTC · read-only · current Replication configuration Low BW optim | |||||||||||||||||||||
| CreplConfigEnabled | 1.3.6.1.4.1.19746.1.8.2.1.1.8 | ReplicationConfigEnabledTC | RO | ||||||||||||||||||
column · ReplicationConfigEnabledTC · read-only · current Replication config Enabled | |||||||||||||||||||||
| CreplConfigTenantUnit | 1.3.6.1.4.1.19746.1.8.2.1.1.9 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current The name of the tenant-unit of a particular replication context. | |||||||||||||||||||||
| NreplicationHistory | 1.3.6.1.4.1.19746.1.8.3 | ||||||||||||||||||||
| TreplicationHistoryTable | 1.3.6.1.4.1.19746.1.8.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of replicationHistoryEntry. | |||||||||||||||||||||
| RreplicationHistoryEntry | 1.3.6.1.4.1.19746.1.8.3.1.1 | NA | |||||||||||||||||||
| CreplHistoryContext | 1.3.6.1.4.1.19746.1.8.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current context ID of replication History source/dest pair | |||||||||||||||||||||
| CreplHistoryDate | 1.3.6.1.4.1.19746.1.8.3.1.1.2 | DDMibDateTC | RO | ||||||||||||||||||
column · DDMibDateTC · read-only · current replication History Date | |||||||||||||||||||||
| CreplHistoryTime | 1.3.6.1.4.1.19746.1.8.3.1.1.3 | DDMibTimeStampTC | RO | ||||||||||||||||||
column · DDMibTimeStampTC · read-only · current replication History Time | |||||||||||||||||||||
| CreplHistoryPreCompWritten | 1.3.6.1.4.1.19746.1.8.3.1.1.4 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Replication History Pre comp bytes written | |||||||||||||||||||||
| CreplHistoryPreCompRemaining | 1.3.6.1.4.1.19746.1.8.3.1.1.5 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Replication History Byte remaining | |||||||||||||||||||||
| CreplHistoryPreCompressed | 1.3.6.1.4.1.19746.1.8.3.1.1.6 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Replication History Precompressed bytes | |||||||||||||||||||||
| CreplHistoryPostFiltered | 1.3.6.1.4.1.19746.1.8.3.1.1.7 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current replication history post filtered bytes | |||||||||||||||||||||
| CreplHistoryPostLowBwOptim | 1.3.6.1.4.1.19746.1.8.3.1.1.8 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Replication history Post Low BW Optimum | |||||||||||||||||||||
| CreplHistoryPostLocalComp | 1.3.6.1.4.1.19746.1.8.3.1.1.9 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Replication History Post Local Comp | |||||||||||||||||||||
| CreplHistoryBytesNetwork | 1.3.6.1.4.1.19746.1.8.3.1.1.10 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Replication History network bytes | |||||||||||||||||||||
| CreplHistorySyncedAsOfTime | 1.3.6.1.4.1.19746.1.8.3.1.1.11 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current Time when the source and destination were in sync, or 0 if the time is unknown | |||||||||||||||||||||
| NreplicationPerformance | 1.3.6.1.4.1.19746.1.8.4 | ||||||||||||||||||||
| TreplicationPerformanceTable | 1.3.6.1.4.1.19746.1.8.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of replicationPerformanceEntry. | |||||||||||||||||||||
| RreplicationPerformanceEntry | 1.3.6.1.4.1.19746.1.8.4.1.1 | NA | |||||||||||||||||||
| CreplPerformancePreCompKBPerSec | 1.3.6.1.4.1.19746.1.8.4.1.1.1 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current Network (KB/s): The size value before compression is applied. Sometimes referred to as 'logical size.' | |||||||||||||||||||||
| CreplPerformanceNetworkKBPerSec | 1.3.6.1.4.1.19746.1.8.4.1.1.2 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current Network (KB/s): The amount of compressed data transferred over the network per second. | |||||||||||||||||||||
| CreplPerformanceStreams | 1.3.6.1.4.1.19746.1.8.4.1.1.3 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current An internal system resource associated with reads and writes. One replication context can use multiple streams for better performance. | |||||||||||||||||||||
| CreplPerformanceBusyReading | 1.3.6.1.4.1.19746.1.8.4.1.1.4 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The time spent reading filesystem data from the local filesystem. Typically this number is the second highest number after Network. On a deployment with high network bandwidth, Reading may be the largest column. | |||||||||||||||||||||
| CreplPerformanceBusyMeta | 1.3.6.1.4.1.19746.1.8.4.1.1.5 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The time spent on miscellaneous bookkeeping activities and replicating filesystem namespace operations. Typically this value is under 50. If this value exceeds 50 on a sustained basis, it may indicate an unusual workload (a large number of file attribute updates, for example). | |||||||||||||||||||||
| CreplPerformanceWaitingDest | 1.3.6.1.4.1.19746.1.8.4.1.1.6 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The time spent waiting due to the receiver not providing the sender enough information on what data to send. Typically this value is low. Exceptions include systems on high-speed networks where the sender is a more powerful Data Domain system than the replica, or where the replica has a higher workload than the sender because the replica is the destination for a multiple replication contexts. | |||||||||||||||||||||
| CreplPerformanceWaitingNetwork | 1.3.6.1.4.1.19746.1.8.4.1.1.7 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The time spent waiting due to the receiver not providing the sender enough information on what data to send. Typically this value is low. Exceptions include systems on high-speed networks where the sender is a more powerful Data Domain system than the replica, or where the replica has a higher workload than the sender because the replica is the destination for a multiple replication contexts. | |||||||||||||||||||||
| Nnfs | 1.3.6.1.4.1.19746.1.9 | ||||||||||||||||||||
| NnfsProperties | 1.3.6.1.4.1.19746.1.9.1 | ||||||||||||||||||||
| SnfsStatus | 1.3.6.1.4.1.19746.1.9.1.1 | NfsStatusTC | RO | ||||||||||||||||||
scalar · NfsStatusTC · read-only · current Status of the network file system | |||||||||||||||||||||
| NnfsClient | 1.3.6.1.4.1.19746.1.9.2 | ||||||||||||||||||||
| TnfsClientTable | 1.3.6.1.4.1.19746.1.9.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of NfsClientEntry. | |||||||||||||||||||||
| RnfsClientEntry | 1.3.6.1.4.1.19746.1.9.2.1.1 | NA | |||||||||||||||||||
| CnfsClientIndex | 1.3.6.1.4.1.19746.1.9.2.1.1.1 | NfsClientIndexTC | NA | ||||||||||||||||||
column · NfsClientIndexTC · not-accessible · current NFS client index | |||||||||||||||||||||
| CnfsClientPath | 1.3.6.1.4.1.19746.1.9.2.1.1.2 | NfsClientPathTC | RO | ||||||||||||||||||
column · NfsClientPathTC · read-only · current NFS client path | |||||||||||||||||||||
| CnfsClientClients | 1.3.6.1.4.1.19746.1.9.2.1.1.3 | NfsClientClientsTC | RO | ||||||||||||||||||
column · NfsClientClientsTC · read-only · current List of NFS clients | |||||||||||||||||||||
| CnfsClientOptions | 1.3.6.1.4.1.19746.1.9.2.1.1.4 | NfsClientOptionsTC | RO | ||||||||||||||||||
column · NfsClientOptionsTC · read-only · current NFS client's options | |||||||||||||||||||||
| NnfsStats | 1.3.6.1.4.1.19746.1.9.3 | ||||||||||||||||||||
| TnfsStatsTable | 1.3.6.1.4.1.19746.1.9.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of NfsStatsEntry. | |||||||||||||||||||||
| RnfsStatsEntry | 1.3.6.1.4.1.19746.1.9.3.1.1 | NA | |||||||||||||||||||
| CnfsStatsIndex | 1.3.6.1.4.1.19746.1.9.3.1.1.1 | NfsStatsIndexTC | NA | ||||||||||||||||||
column · NfsStatsIndexTC · not-accessible · current NFS resource index | |||||||||||||||||||||
| CnfsStatsExportPoint | 1.3.6.1.4.1.19746.1.9.3.1.1.2 | NfsStatsExportPointTC | RO | ||||||||||||||||||
column · NfsStatsExportPointTC · read-only · current NFS export point | |||||||||||||||||||||
| CnfsStatsFilesystemType | 1.3.6.1.4.1.19746.1.9.3.1.1.3 | NfsStatsFilesystemTypeTC | RO | ||||||||||||||||||
column · NfsStatsFilesystemTypeTC · read-only · current File system type | |||||||||||||||||||||
| CnfsStatsCacheEntry | 1.3.6.1.4.1.19746.1.9.3.1.1.4 | NfsStatsCacheEntryTC | RO | ||||||||||||||||||
column · NfsStatsCacheEntryTC · read-only · current Number of cache entries | |||||||||||||||||||||
| CnfsStatsFileHandleLookup | 1.3.6.1.4.1.19746.1.9.3.1.1.5 | NfsStatsFileHandleLookupTC | RO | ||||||||||||||||||
column · NfsStatsFileHandleLookupTC · read-only · current File handle lookup count | |||||||||||||||||||||
| CnfsStatsMaxCacheSize | 1.3.6.1.4.1.19746.1.9.3.1.1.6 | NfsStatsMaxCacheSizeTC | RO | ||||||||||||||||||
column · NfsStatsMaxCacheSizeTC · read-only · current Max cache size | |||||||||||||||||||||
| CnfsStatsCurrentOpenStreams | 1.3.6.1.4.1.19746.1.9.3.1.1.7 | NfsStatsCurrentOpenStreamsTC | RO | ||||||||||||||||||
column · NfsStatsCurrentOpenStreamsTC · read-only · current Current open stream count | |||||||||||||||||||||
| NnfsActive | 1.3.6.1.4.1.19746.1.9.4 | ||||||||||||||||||||
| TnfsActiveTable | 1.3.6.1.4.1.19746.1.9.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of Nfs Active Clients. | |||||||||||||||||||||
| RnfsActiveEntry | 1.3.6.1.4.1.19746.1.9.4.1.1 | NA | |||||||||||||||||||
| CnfsActiveIndex | 1.3.6.1.4.1.19746.1.9.4.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current NFS Active index | |||||||||||||||||||||
| CnfsActivePath | 1.3.6.1.4.1.19746.1.9.4.1.1.2 | DDMibTableString1024TC | RO | ||||||||||||||||||
column · DDMibTableString1024TC · read-only · current NFS Active client path | |||||||||||||||||||||
| CnfsActiveClients | 1.3.6.1.4.1.19746.1.9.4.1.1.3 | DDMibTableString1024TC | RO | ||||||||||||||||||
column · DDMibTableString1024TC · read-only · current NFS Active Client | |||||||||||||||||||||
| NnfsPort | 1.3.6.1.4.1.19746.1.9.5 | ||||||||||||||||||||
| TnfsPortTable | 1.3.6.1.4.1.19746.1.9.5.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of NfsPortEntry. | |||||||||||||||||||||
| RnfsPortEntry | 1.3.6.1.4.1.19746.1.9.5.1.1 | NA | |||||||||||||||||||
| CnfsPortIndex | 1.3.6.1.4.1.19746.1.9.5.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current NFS Port index | |||||||||||||||||||||
| CnfsPortService | 1.3.6.1.4.1.19746.1.9.5.1.1.2 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current NFS Port Service Name | |||||||||||||||||||||
| CnfsPortPort | 1.3.6.1.4.1.19746.1.9.5.1.1.3 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current NFS Service Port | |||||||||||||||||||||
| Ncifs | 1.3.6.1.4.1.19746.1.10 | ||||||||||||||||||||
| NcifsProperties | 1.3.6.1.4.1.19746.1.10.1 | ||||||||||||||||||||
| ScifsStatus | 1.3.6.1.4.1.19746.1.10.1.1 | CifsStatusTC | RO | ||||||||||||||||||
scalar · CifsStatusTC · read-only · current CIFS status | |||||||||||||||||||||
| NcifsConfig | 1.3.6.1.4.1.19746.1.10.2 | ||||||||||||||||||||
| ScifsConfigMode | 1.3.6.1.4.1.19746.1.10.2.1 | CifsConfigModeTC | RO | ||||||||||||||||||
scalar · CifsConfigModeTC · read-only · current CIFS configuration mode | |||||||||||||||||||||
| ScifsConfigWINSServer | 1.3.6.1.4.1.19746.1.10.2.2 | CifsConfigWINSServerTC | RO | ||||||||||||||||||
scalar · CifsConfigWINSServerTC · read-only · current CIFS WINS server | |||||||||||||||||||||
| ScifsConfigNetBIOSHostname | 1.3.6.1.4.1.19746.1.10.2.3 | CifsConfigNetBIOSHostnameTC | RO | ||||||||||||||||||
scalar · CifsConfigNetBIOSHostnameTC · read-only · current CIFS Net BIOS hostname | |||||||||||||||||||||
| ScifsConfigDomainController | 1.3.6.1.4.1.19746.1.10.2.4 | CifsConfigDomainControllerTC | RO | ||||||||||||||||||
scalar · CifsConfigDomainControllerTC · read-only · current CIFS domain controller | |||||||||||||||||||||
| ScifsConfigDNS | 1.3.6.1.4.1.19746.1.10.2.5 | CifsConfigDNSTC | RO | ||||||||||||||||||
scalar · CifsConfigDNSTC · read-only · current CIFS DNS server | |||||||||||||||||||||
| ScifsConfigGroupName | 1.3.6.1.4.1.19746.1.10.2.6 | CifsConfigGroupNameTC | RO | ||||||||||||||||||
scalar · CifsConfigGroupNameTC · read-only · current CIFS configuration group name | |||||||||||||||||||||
| ScifsConfigMaxConnection | 1.3.6.1.4.1.19746.1.10.2.7 | CifsConfigMaxConnectionTC | RO | ||||||||||||||||||
scalar · CifsConfigMaxConnectionTC · read-only · current CIFS configuration maximum connection | |||||||||||||||||||||
| ScifsConfigMaxOpenFilesPerConnection | 1.3.6.1.4.1.19746.1.10.2.8 | CifsConfigMaxOpenFilesPerConnectionTC | RO | deprecated | |||||||||||||||||
scalar · CifsConfigMaxOpenFilesPerConnectionTC · read-only · deprecated CIFS configuration maximum open files per connection | |||||||||||||||||||||
| ScifsConfigMaxOpenFiles | 1.3.6.1.4.1.19746.1.10.2.9 | Counter32 | RO | ||||||||||||||||||
scalar · Counter32 · read-only · current CIFS configuration maximum open files | |||||||||||||||||||||
| NcifsShare | 1.3.6.1.4.1.19746.1.10.3 | ||||||||||||||||||||
| TcifsShareTable | 1.3.6.1.4.1.19746.1.10.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of CifsShareEntry. | |||||||||||||||||||||
| RcifsShareEntry | 1.3.6.1.4.1.19746.1.10.3.1.1 | NA | |||||||||||||||||||
| CcifsShareIndex | 1.3.6.1.4.1.19746.1.10.3.1.1.1 | CifsShareIndexTC | NA | ||||||||||||||||||
column · CifsShareIndexTC · not-accessible · current CIFS share index | |||||||||||||||||||||
| CcifsShareName | 1.3.6.1.4.1.19746.1.10.3.1.1.2 | CifsShareNameTC | RO | ||||||||||||||||||
column · CifsShareNameTC · read-only · current CIFS share name | |||||||||||||||||||||
| CcifsSharePath | 1.3.6.1.4.1.19746.1.10.3.1.1.3 | CifsSharePathTC | RO | ||||||||||||||||||
column · CifsSharePathTC · read-only · current CIFS share path | |||||||||||||||||||||
| CcifsShareClients | 1.3.6.1.4.1.19746.1.10.3.1.1.4 | CifsShareClientsTC | RO | ||||||||||||||||||
column · CifsShareClientsTC · read-only · current CIFS share clients | |||||||||||||||||||||
| CcifsShareUser | 1.3.6.1.4.1.19746.1.10.3.1.1.5 | CifsShareUserTC | RO | ||||||||||||||||||
column · CifsShareUserTC · read-only · current CIFS share user | |||||||||||||||||||||
| CcifsShareComment | 1.3.6.1.4.1.19746.1.10.3.1.1.6 | CifsShareCommentTC | RO | ||||||||||||||||||
column · CifsShareCommentTC · read-only · current CIFS share comment | |||||||||||||||||||||
| CcifsShareBrowsing | 1.3.6.1.4.1.19746.1.10.3.1.1.7 | CifsShareBrowsingTC | RO | ||||||||||||||||||
column · CifsShareBrowsingTC · read-only · current CIFS share browsing | |||||||||||||||||||||
| CcifsShareWriteable | 1.3.6.1.4.1.19746.1.10.3.1.1.8 | CifsShareWriteableTC | RO | ||||||||||||||||||
column · CifsShareWriteableTC · read-only · current CIFS share writeable | |||||||||||||||||||||
| CcifsShareMaxConnection | 1.3.6.1.4.1.19746.1.10.3.1.1.9 | CifsShareMaxConnectionTC | RO | ||||||||||||||||||
column · CifsShareMaxConnectionTC · read-only · current CIFS share maximum connection | |||||||||||||||||||||
| NcifsOptions | 1.3.6.1.4.1.19746.1.10.5 | ||||||||||||||||||||
| TcifsOptionsTable | 1.3.6.1.4.1.19746.1.10.5.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of CifsOptionsEntry. | |||||||||||||||||||||
| RcifsOptionsEntry | 1.3.6.1.4.1.19746.1.10.5.1.1 | NA | |||||||||||||||||||
| CcifsOptionsIndex | 1.3.6.1.4.1.19746.1.10.5.1.1.1 | CifsOptionsIndexTC | NA | ||||||||||||||||||
column · CifsOptionsIndexTC · not-accessible · current CIFS Options index | |||||||||||||||||||||
| CcifsOptionsName | 1.3.6.1.4.1.19746.1.10.5.1.1.2 | CifsOptionsNameTC | RO | ||||||||||||||||||
column · CifsOptionsNameTC · read-only · current CIFS Options name | |||||||||||||||||||||
| CcifsOptionsValue | 1.3.6.1.4.1.19746.1.10.5.1.1.3 | CifsOptionsValueTC | RO | ||||||||||||||||||
column · CifsOptionsValueTC · read-only · current CIFS Options Value | |||||||||||||||||||||
| Nvtl | 1.3.6.1.4.1.19746.1.11 | ||||||||||||||||||||
| NvtlProperties | 1.3.6.1.4.1.19746.1.11.1 | ||||||||||||||||||||
| SvtlAdminState | 1.3.6.1.4.1.19746.1.11.1.1 | VtlAdminStateTC | RO | ||||||||||||||||||
scalar · VtlAdminStateTC · read-only · current State of VTL administration | |||||||||||||||||||||
| SvtlProcessState | 1.3.6.1.4.1.19746.1.11.1.2 | VtlProcessStateTC | RO | ||||||||||||||||||
scalar · VtlProcessStateTC · read-only · current State of VTL process | |||||||||||||||||||||
| NvtlConfiguration | 1.3.6.1.4.1.19746.1.11.2 | ||||||||||||||||||||
| NvtlLibrary | 1.3.6.1.4.1.19746.1.11.2.1 | ||||||||||||||||||||
| TvtlLibraryTable | 1.3.6.1.4.1.19746.1.11.2.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of VtlLibraryEntry. | |||||||||||||||||||||
| RvtlLibraryEntry | 1.3.6.1.4.1.19746.1.11.2.1.1.1 | NA | |||||||||||||||||||
| CvtlLibraryIndex | 1.3.6.1.4.1.19746.1.11.2.1.1.1.1 | VtlLibraryIndexTC | NA | ||||||||||||||||||
column · VtlLibraryIndexTC · not-accessible · current VTL Library index | |||||||||||||||||||||
| CvtlLibraryName | 1.3.6.1.4.1.19746.1.11.2.1.1.1.2 | VtlLibraryNameTC | RO | ||||||||||||||||||
column · VtlLibraryNameTC · read-only · current VTL library name | |||||||||||||||||||||
| CvtlLibraryVendor | 1.3.6.1.4.1.19746.1.11.2.1.1.1.3 | VtlLibraryVendorTC | RO | ||||||||||||||||||
column · VtlLibraryVendorTC · read-only · current VTL library vendor | |||||||||||||||||||||
| CvtlLibraryModel | 1.3.6.1.4.1.19746.1.11.2.1.1.1.4 | VtlLibraryModelTC | RO | ||||||||||||||||||
column · VtlLibraryModelTC · read-only · current VTL library model | |||||||||||||||||||||
| CvtlLibraryRevision | 1.3.6.1.4.1.19746.1.11.2.1.1.1.5 | VtlLibraryRevisionTC | RO | ||||||||||||||||||
column · VtlLibraryRevisionTC · read-only · current VTL library revision | |||||||||||||||||||||
| CvtlLibrarySerial | 1.3.6.1.4.1.19746.1.11.2.1.1.1.6 | VtlLibrarySerialTC | RO | ||||||||||||||||||
column · VtlLibrarySerialTC · read-only · current VTL library serial | |||||||||||||||||||||
| CvtlLibraryTotalDrives | 1.3.6.1.4.1.19746.1.11.2.1.1.1.7 | VtlLibraryTotalDrivesTC | RO | ||||||||||||||||||
column · VtlLibraryTotalDrivesTC · read-only · current VTL library total drives | |||||||||||||||||||||
| CvtlLibraryTotalSlots | 1.3.6.1.4.1.19746.1.11.2.1.1.1.8 | VtlLibraryTotalSlotsTC | RO | ||||||||||||||||||
column · VtlLibraryTotalSlotsTC · read-only · current VTL library total slots | |||||||||||||||||||||
| CvtlLibraryTotalCaps | 1.3.6.1.4.1.19746.1.11.2.1.1.1.9 | VtlLibraryTotalCapsTC | RO | ||||||||||||||||||
column · VtlLibraryTotalCapsTC · read-only · current VTL library total caps | |||||||||||||||||||||
| CvtlLibraryStatus | 1.3.6.1.4.1.19746.1.11.2.1.1.1.10 | VtlLibraryStatusTC | RO | ||||||||||||||||||
column · VtlLibraryStatusTC · read-only · current VTL library status | |||||||||||||||||||||
| NvtlDrive | 1.3.6.1.4.1.19746.1.11.2.2 | ||||||||||||||||||||
| TvtlDriveTable | 1.3.6.1.4.1.19746.1.11.2.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of VtlDriveEntry. | |||||||||||||||||||||
| RvtlDriveEntry | 1.3.6.1.4.1.19746.1.11.2.2.1.1 | NA | |||||||||||||||||||
| CvtlDriveIndex | 1.3.6.1.4.1.19746.1.11.2.2.1.1.1 | VtlDriveIndexTC | NA | ||||||||||||||||||
column · VtlDriveIndexTC · not-accessible · current VTL drive index | |||||||||||||||||||||
| CvtlDriveName | 1.3.6.1.4.1.19746.1.11.2.2.1.1.2 | VtlDriveNameTC | RO | ||||||||||||||||||
column · VtlDriveNameTC · read-only · current VTL drive name | |||||||||||||||||||||
| CvtlDriveVendor | 1.3.6.1.4.1.19746.1.11.2.2.1.1.3 | VtlDriveVendorTC | RO | ||||||||||||||||||
column · VtlDriveVendorTC · read-only · current VTL drive vendor | |||||||||||||||||||||
| CvtlDriveModel | 1.3.6.1.4.1.19746.1.11.2.2.1.1.4 | VtlDriveModelTC | RO | ||||||||||||||||||
column · VtlDriveModelTC · read-only · current VTL drive model | |||||||||||||||||||||
| CvtlDriveRevision | 1.3.6.1.4.1.19746.1.11.2.2.1.1.5 | VtlDriveRevisionTC | RO | ||||||||||||||||||
column · VtlDriveRevisionTC · read-only · current VTL drive revision | |||||||||||||||||||||
| CvtlDriveSerial | 1.3.6.1.4.1.19746.1.11.2.2.1.1.6 | VtlDriveSerialTC | RO | ||||||||||||||||||
column · VtlDriveSerialTC · read-only · current VTL drive serial | |||||||||||||||||||||
| CvtlDriveLibraryName | 1.3.6.1.4.1.19746.1.11.2.2.1.1.7 | VtlLibraryNameTC | RO | ||||||||||||||||||
column · VtlLibraryNameTC · read-only · current VTL drive library name | |||||||||||||||||||||
| CvtlDriveStatus | 1.3.6.1.4.1.19746.1.11.2.2.1.1.8 | VtlDriveStatusTC | RO | ||||||||||||||||||
column · VtlDriveStatusTC · read-only · current VTL drive status | |||||||||||||||||||||
| CvtlDriveTapeVolume | 1.3.6.1.4.1.19746.1.11.2.2.1.1.9 | VtlDriveTapeVolumeTC | RO | ||||||||||||||||||
column · VtlDriveTapeVolumeTC · read-only · current VTL drive tape volume | |||||||||||||||||||||
| NvtlPort | 1.3.6.1.4.1.19746.1.11.2.3 | ||||||||||||||||||||
| TvtlPortTable | 1.3.6.1.4.1.19746.1.11.2.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of VtlPortEntry. | |||||||||||||||||||||
| RvtlPortEntry | 1.3.6.1.4.1.19746.1.11.2.3.1.1 | NA | |||||||||||||||||||
| CvtlPortIndex | 1.3.6.1.4.1.19746.1.11.2.3.1.1.1 | VtlPortIndexTC | NA | ||||||||||||||||||
column · VtlPortIndexTC · not-accessible · current VTL Port index | |||||||||||||||||||||
| CvtlPortName | 1.3.6.1.4.1.19746.1.11.2.3.1.1.2 | VtlPortNameTC | RO | ||||||||||||||||||
column · VtlPortNameTC · read-only · current VTL Port name | |||||||||||||||||||||
| CvtlPortID | 1.3.6.1.4.1.19746.1.11.2.3.1.1.3 | VtlPortIDTC | RO | ||||||||||||||||||
column · VtlPortIDTC · read-only · current VTL Port ID | |||||||||||||||||||||
| CvtlPortModel | 1.3.6.1.4.1.19746.1.11.2.3.1.1.4 | VtlPortModelTC | RO | ||||||||||||||||||
column · VtlPortModelTC · read-only · current VTL Port model | |||||||||||||||||||||
| CvtlPortFirmware | 1.3.6.1.4.1.19746.1.11.2.3.1.1.5 | VtlPortFirmwareTC | RO | ||||||||||||||||||
column · VtlPortFirmwareTC · read-only · current VTL Port Firmware Version | |||||||||||||||||||||
| CvtlPortWWNN | 1.3.6.1.4.1.19746.1.11.2.3.1.1.6 | VtlPortWWNNTC | RO | ||||||||||||||||||
column · VtlPortWWNNTC · read-only · current VTL Port WWNN address | |||||||||||||||||||||
| CvtlPortWWPN | 1.3.6.1.4.1.19746.1.11.2.3.1.1.7 | VtlPortWWPNTC | RO | ||||||||||||||||||
column · VtlPortWWPNTC · read-only · current VTL Port WWPN Address | |||||||||||||||||||||
| CvtlPortConnectionType | 1.3.6.1.4.1.19746.1.11.2.3.1.1.8 | VtlPortConnectionTypeTC | RO | ||||||||||||||||||
column · VtlPortConnectionTypeTC · read-only · current VTL Port Connection Type | |||||||||||||||||||||
| CvtlPortSpeed | 1.3.6.1.4.1.19746.1.11.2.3.1.1.9 | VtlPortSpeedTC | RO | ||||||||||||||||||
column · VtlPortSpeedTC · read-only · current VTL Port Speed in Gibs | |||||||||||||||||||||
| CvtlPortEnabled | 1.3.6.1.4.1.19746.1.11.2.3.1.1.10 | VtlPortEnabledTC | RO | ||||||||||||||||||
column · VtlPortEnabledTC · read-only · current VTL Port Enabled | |||||||||||||||||||||
| CvtlPortStatus | 1.3.6.1.4.1.19746.1.11.2.3.1.1.11 | VtlPortStatusTC | RO | ||||||||||||||||||
column · VtlPortStatusTC · read-only · current VTL Port Status | |||||||||||||||||||||
| CvtlPortTrapIndex | 1.3.6.1.4.1.19746.1.11.2.3.1.1.12 | VtlPortIndexTC | RO | ||||||||||||||||||
column · VtlPortIndexTC · read-only · current VTL Port index | |||||||||||||||||||||
| NvtlTape | 1.3.6.1.4.1.19746.1.11.2.4 | ||||||||||||||||||||
| TvtlTapeTable | 1.3.6.1.4.1.19746.1.11.2.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of VtlTapeEntry. | |||||||||||||||||||||
| RvtlTapeEntry | 1.3.6.1.4.1.19746.1.11.2.4.1.1 | NA | |||||||||||||||||||
| CvtlTapeIndex | 1.3.6.1.4.1.19746.1.11.2.4.1.1.1 | VtlTapeIndexTC | NA | ||||||||||||||||||
column · VtlTapeIndexTC · not-accessible · current VTL Tape index | |||||||||||||||||||||
| CvtlTapeBarCode | 1.3.6.1.4.1.19746.1.11.2.4.1.1.2 | VtlTapeBarCodeTC | RO | ||||||||||||||||||
column · VtlTapeBarCodeTC · read-only · current VTL Tape BarCode | |||||||||||||||||||||
| CvtlTapePool | 1.3.6.1.4.1.19746.1.11.2.4.1.1.3 | VtlTapePoolTC | RO | ||||||||||||||||||
column · VtlTapePoolTC · read-only · current VTL Tape Pool | |||||||||||||||||||||
| CvtlTapeLocation | 1.3.6.1.4.1.19746.1.11.2.4.1.1.4 | VtlTapeLocationTC | RO | ||||||||||||||||||
column · VtlTapeLocationTC · read-only · current VTL Tape Location | |||||||||||||||||||||
| CvtlTapeState | 1.3.6.1.4.1.19746.1.11.2.4.1.1.5 | VtlTapeStateTC | RO | ||||||||||||||||||
column · VtlTapeStateTC · read-only · current VTL Tape State | |||||||||||||||||||||
| CvtlTapeSize | 1.3.6.1.4.1.19746.1.11.2.4.1.1.6 | VtlTapeSizeTC | RO | ||||||||||||||||||
column · VtlTapeSizeTC · read-only · current VTL Tape Size | |||||||||||||||||||||
| CvtlTapeUsed | 1.3.6.1.4.1.19746.1.11.2.4.1.1.7 | VtlTapeUsedTC | RO | ||||||||||||||||||
column · VtlTapeUsedTC · read-only · current VTL Tape Used | |||||||||||||||||||||
| CvtlTapeComp | 1.3.6.1.4.1.19746.1.11.2.4.1.1.8 | VtlTapeCompTC | RO | ||||||||||||||||||
column · VtlTapeCompTC · read-only · current VTL Tape Compression | |||||||||||||||||||||
| CvtlTapeModTime | 1.3.6.1.4.1.19746.1.11.2.4.1.1.9 | VtlTapeModTimeTC | RO | ||||||||||||||||||
column · VtlTapeModTimeTC · read-only · current VTL Tape status | |||||||||||||||||||||
| NvtlPool | 1.3.6.1.4.1.19746.1.11.2.6 | ||||||||||||||||||||
| TvtlPoolTable | 1.3.6.1.4.1.19746.1.11.2.6.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of VtlPoolEntry. | |||||||||||||||||||||
| RvtlPoolEntry | 1.3.6.1.4.1.19746.1.11.2.6.1.1 | NA | |||||||||||||||||||
| CvtlPoolIndex | 1.3.6.1.4.1.19746.1.11.2.6.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current VTL Pool index | |||||||||||||||||||||
| CvtlPoolPool | 1.3.6.1.4.1.19746.1.11.2.6.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Pool Pool | |||||||||||||||||||||
| CvtlPoolStatus | 1.3.6.1.4.1.19746.1.11.2.6.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Pool Status | |||||||||||||||||||||
| CvtlPoolTapes | 1.3.6.1.4.1.19746.1.11.2.6.1.1.4 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Pool Tapes | |||||||||||||||||||||
| CvtlPoolSize | 1.3.6.1.4.1.19746.1.11.2.6.1.1.5 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Pool Size | |||||||||||||||||||||
| CvtlPoolUsed | 1.3.6.1.4.1.19746.1.11.2.6.1.1.6 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Pool Used | |||||||||||||||||||||
| CvtlPoolComp | 1.3.6.1.4.1.19746.1.11.2.6.1.1.7 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Pool Compression | |||||||||||||||||||||
| NvtlGroups | 1.3.6.1.4.1.19746.1.11.2.7 | ||||||||||||||||||||
| TvtlGroupTable | 1.3.6.1.4.1.19746.1.11.2.7.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of VtlGroupEntry. | |||||||||||||||||||||
| RvtlGroupEntry | 1.3.6.1.4.1.19746.1.11.2.7.1.1 | NA | |||||||||||||||||||
| CvtlGroupIndex | 1.3.6.1.4.1.19746.1.11.2.7.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current VTL Group index | |||||||||||||||||||||
| CvtlGroupName | 1.3.6.1.4.1.19746.1.11.2.7.1.1.2 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current VTL Group Name | |||||||||||||||||||||
| CvtlGroupInitiaterCount | 1.3.6.1.4.1.19746.1.11.2.7.1.1.3 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current VTL Group Initiater Count | |||||||||||||||||||||
| CvtlGroupDeviceCount | 1.3.6.1.4.1.19746.1.11.2.7.1.1.4 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current VTL Group Device Count | |||||||||||||||||||||
| TvtlGroupDeviceTable | 1.3.6.1.4.1.19746.1.11.2.7.2 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the devices in VTL groups. It provides information such as the Device Name, the Device LUN, the Primary Ports, Secondary Ports, In-Use Ports, and Group Name. It is comprised of entries of VtlGroupDeviceEntry. | |||||||||||||||||||||
| RvtlGroupDeviceEntry | 1.3.6.1.4.1.19746.1.11.2.7.2.1 | NA | |||||||||||||||||||
row · not-accessible · current Information about the devices in a VTL group. | |||||||||||||||||||||
| CvtlGroupDeviceIndex | 1.3.6.1.4.1.19746.1.11.2.7.2.1.2 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current The index of a VTL Device. | |||||||||||||||||||||
| CvtlGroupDeviceGroupName | 1.3.6.1.4.1.19746.1.11.2.7.2.1.3 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The name of a VTL Group. | |||||||||||||||||||||
| CvtlGroupDeviceDeviceName | 1.3.6.1.4.1.19746.1.11.2.7.2.1.4 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The name of a VTL Device. | |||||||||||||||||||||
| CvtlGroupDeviceLun | 1.3.6.1.4.1.19746.1.11.2.7.2.1.5 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The LUN (Logical Unit Number) of a VTL Device. | |||||||||||||||||||||
| CvtlGroupDevicePrimaryPorts | 1.3.6.1.4.1.19746.1.11.2.7.2.1.6 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current The Primary Ports of a VTL Device. This entry specifies a set of ports that the device will be visible on. If 'all' is provided the device is visible on all ports. If 'none' is provided the device is visible on none of the ports. | |||||||||||||||||||||
| CvtlGroupDeviceSecondaryPorts | 1.3.6.1.4.1.19746.1.11.2.7.2.1.7 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current The Secondary Ports of a VTL Device. This entry specifies a second set of ports that the device will be visible on. The administrator can switch the ports in use in a group to the primary or secondary port list. | |||||||||||||||||||||
| CvtlGroupDeviceInUsePorts | 1.3.6.1.4.1.19746.1.11.2.7.2.1.8 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current The In-Use Ports of a VTL Device. The port list that the device is visible on is the in-use port list, which can be the primary or secondary port list. | |||||||||||||||||||||
| NvtlInitiator | 1.3.6.1.4.1.19746.1.11.2.8 | ||||||||||||||||||||
| TvtlInitiatorTable | 1.3.6.1.4.1.19746.1.11.2.8.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of VtlInitiatorEntry. | |||||||||||||||||||||
| RvtlInitiatorEntry | 1.3.6.1.4.1.19746.1.11.2.8.1.1 | NA | |||||||||||||||||||
| CvtlInitiatorIndex | 1.3.6.1.4.1.19746.1.11.2.8.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current VTL Initiator index | |||||||||||||||||||||
| CvtlInitiatorName | 1.3.6.1.4.1.19746.1.11.2.8.1.1.2 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current VTL Initiator Name | |||||||||||||||||||||
| CvtlInitiatorStatus | 1.3.6.1.4.1.19746.1.11.2.8.1.1.3 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current VTL Initiator Status | |||||||||||||||||||||
| CvtlInitiatorGroup | 1.3.6.1.4.1.19746.1.11.2.8.1.1.4 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current VTL Initiator Group | |||||||||||||||||||||
| CvtlInitiatorWWNN | 1.3.6.1.4.1.19746.1.11.2.8.1.1.5 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Initiator WWNN | |||||||||||||||||||||
| CvtlInitiatorWWPN | 1.3.6.1.4.1.19746.1.11.2.8.1.1.6 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current VTL Initiator WWPN | |||||||||||||||||||||
| CvtlInitiatorPort | 1.3.6.1.4.1.19746.1.11.2.8.1.1.7 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current VTL Initiator Port | |||||||||||||||||||||
| NvtlStats | 1.3.6.1.4.1.19746.1.11.3 | ||||||||||||||||||||
| TvtlStatsTable | 1.3.6.1.4.1.19746.1.11.3.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains detailed statistical information about the individual VTL Ports on a Data Domain System. It includes the count of Control Commands, Write Commands, and Read Commands. The amount of data In, and Out. The count of Link Failures, LIP count, Sync Losses, Signal Losses, Prim Seq Proto Errors, Invalid Tx Words, and Invalid CRCs. It is comprised of entries of VtlStatsEntry. | |||||||||||||||||||||
| RvtlStatsEntry | 1.3.6.1.4.1.19746.1.11.3.1.1 | NA | |||||||||||||||||||
| CvtlStatsIndex | 1.3.6.1.4.1.19746.1.11.3.1.1.1 | VtlStatsIndexTC | NA | ||||||||||||||||||
column · VtlStatsIndexTC · not-accessible · current VTL Stats Index. The index of the VTL Per-Port Statistical entry. | |||||||||||||||||||||
| CvtlStatsPort | 1.3.6.1.4.1.19746.1.11.3.1.1.2 | VtlStatsPortTC | RO | ||||||||||||||||||
column · VtlStatsPortTC · read-only · current VTL Stats Port. The physical VTL port number. | |||||||||||||||||||||
| CvtlStatsConrolCommands | 1.3.6.1.4.1.19746.1.11.3.1.1.3 | VtlStatsConrolCommandsTC | RO | ||||||||||||||||||
column · VtlStatsConrolCommandsTC · read-only · current VTL Stats Control Commands. The number of non read/write commands. | |||||||||||||||||||||
| CvtlStatsWriteCommands | 1.3.6.1.4.1.19746.1.11.3.1.1.4 | VtlStatsWriteCommandsTC | RO | ||||||||||||||||||
column · VtlStatsWriteCommandsTC · read-only · current VTL Stats Write Commands. The number of WRITE commands. | |||||||||||||||||||||
| CvtlStatsReadCommands | 1.3.6.1.4.1.19746.1.11.3.1.1.5 | VtlStatsReadCommandsTC | RO | ||||||||||||||||||
column · VtlStatsReadCommandsTC · read-only · current VTL Stats Read Commands. The number of READ commands. | |||||||||||||||||||||
| CvtlStatsIn | 1.3.6.1.4.1.19746.1.11.3.1.1.6 | VtlStatsInTC | RO | ||||||||||||||||||
column · VtlStatsInTC · read-only · current VTL Stats In. The number of megabytes written to the specific port. | |||||||||||||||||||||
| CvtlStatsOut | 1.3.6.1.4.1.19746.1.11.3.1.1.7 | VtlStatsOutTC | RO | ||||||||||||||||||
column · VtlStatsOutTC · read-only · current VTL Stats Out. The number of megabytes read from the specific port. | |||||||||||||||||||||
| CvtlStatsLinkFailures | 1.3.6.1.4.1.19746.1.11.3.1.1.8 | VtlStatsLinkFailuresTC | RO | ||||||||||||||||||
column · VtlStatsLinkFailuresTC · read-only · current VTL Stats Link Failures. The count of Link Failures. | |||||||||||||||||||||
| CvtlStatsLIPCount | 1.3.6.1.4.1.19746.1.11.3.1.1.9 | VtlStatsLIPCountTC | RO | ||||||||||||||||||
column · VtlStatsLIPCountTC · read-only · current VTL Stats LIP Count. The number of LIPs. | |||||||||||||||||||||
| CvtlStatsSyncLosses | 1.3.6.1.4.1.19746.1.11.3.1.1.10 | VtlStatsSyncLossesTC | RO | ||||||||||||||||||
column · VtlStatsSyncLossesTC · read-only · current VTL Stats Sync Losses. The number of times sync loss was detected. | |||||||||||||||||||||
| CvtlStatsSignalLosses | 1.3.6.1.4.1.19746.1.11.3.1.1.11 | VtlStatsSignalLossesTC | RO | ||||||||||||||||||
column · VtlStatsSignalLossesTC · read-only · current VTL Stats Signal Losses. The number of times loss of signal was detected. | |||||||||||||||||||||
| CvtlStatsPrimSeqProtoErrors | 1.3.6.1.4.1.19746.1.11.3.1.1.12 | VtlStatsPrimSeqProtoErrorsTC | RO | ||||||||||||||||||
column · VtlStatsPrimSeqProtoErrorsTC · read-only · current VTL Stats Prim Seq Proto Errors. The count of errors in the Primitive Sequence Protocol. | |||||||||||||||||||||
| CvtlStatsInvalidTxWords | 1.3.6.1.4.1.19746.1.11.3.1.1.13 | VtlStatsInvalidTxWordsTC | RO | ||||||||||||||||||
column · VtlStatsInvalidTxWordsTC · read-only · current VTL Stats Invalid Tx Words. The number of invalid TX words. | |||||||||||||||||||||
| CvtlStatsInvalidCRCs | 1.3.6.1.4.1.19746.1.11.3.1.1.14 | VtlStatsInvalidCRCsTC | RO | ||||||||||||||||||
column · VtlStatsInvalidCRCsTC · read-only · current VTL Stats Invalid CRCs. The number of frames received with bad CRC. | |||||||||||||||||||||
| Nddboost | 1.3.6.1.4.1.19746.1.12 | ||||||||||||||||||||
| NddboostProperties | 1.3.6.1.4.1.19746.1.12.1 | ||||||||||||||||||||
| SddboostStatus | 1.3.6.1.4.1.19746.1.12.1.1 | DDboostStatusTC | RO | ||||||||||||||||||
scalar · DDboostStatusTC · read-only · current The status of the DDBoost interface group on a DD system. | |||||||||||||||||||||
| SddboostUser | 1.3.6.1.4.1.19746.1.12.1.2 | DDboostUserTC | RO | deprecated | |||||||||||||||||
scalar · DDboostUserTC · read-only · deprecated DDBoost User. | |||||||||||||||||||||
| SddboostIfGroupStatus | 1.3.6.1.4.1.19746.1.12.1.3 | DDMibStatusTC | RO | deprecated | |||||||||||||||||
scalar · DDMibStatusTC · read-only · deprecated DDBoost IfGroup Status. | |||||||||||||||||||||
| TddboostUserTable | 1.3.6.1.4.1.19746.1.12.1.4 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about DDBoost users. | |||||||||||||||||||||
| RddboostUserEntry | 1.3.6.1.4.1.19746.1.12.1.4.1 | NA | |||||||||||||||||||
| CddboostUserIdx | 1.3.6.1.4.1.19746.1.12.1.4.1.1 | DDboostStatsIndexTC | NA | ||||||||||||||||||
column · DDboostStatsIndexTC · not-accessible · current DDBoost users table index. | |||||||||||||||||||||
| CddboostUserName | 1.3.6.1.4.1.19746.1.12.1.4.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The name of a Ddboost user. | |||||||||||||||||||||
| CddboostUserDefaultTenantUnit | 1.3.6.1.4.1.19746.1.12.1.4.1.3 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The default tenant unit that is associated with a specific DDBoost user. | |||||||||||||||||||||
| TddboostIfGroupTable | 1.3.6.1.4.1.19746.1.12.1.5 | NA | |||||||||||||||||||
table · not-accessible · current DDBoost IfGroup table containing interface group information. | |||||||||||||||||||||
| RddboostIfGroupEntry | 1.3.6.1.4.1.19746.1.12.1.5.1 | NA | |||||||||||||||||||
| CddboostIfGroupIdx | 1.3.6.1.4.1.19746.1.12.1.5.1.1 | DDboostStatsIndexTC | NA | ||||||||||||||||||
column · DDboostStatsIndexTC · not-accessible · current DDBoost IfGroup table index. | |||||||||||||||||||||
| CddboostIfGroupName | 1.3.6.1.4.1.19746.1.12.1.5.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The name of DDBoost IfGroup. | |||||||||||||||||||||
| CddboostIfGroupCurrentStatus | 1.3.6.1.4.1.19746.1.12.1.5.1.3 | DDMibStatusTC | RO | ||||||||||||||||||
column · DDMibStatusTC · read-only · current The status of a DDBoost IfGroup. Possible values are: 'enabled' or 'disabled'. | |||||||||||||||||||||
| NddboostStats | 1.3.6.1.4.1.19746.1.12.2 | ||||||||||||||||||||
| TddboostStatsTable | 1.3.6.1.4.1.19746.1.12.2.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST stats table containing byte statistics information for DDBOOST | |||||||||||||||||||||
| RddboostStatsEntry | 1.3.6.1.4.1.19746.1.12.2.1.1 | NA | |||||||||||||||||||
| CddboostStatsIndex | 1.3.6.1.4.1.19746.1.12.2.1.1.1 | DDboostStatsIndexTC | NA | ||||||||||||||||||
column · DDboostStatsIndexTC · not-accessible · current ddboost Stats Table index | |||||||||||||||||||||
| CddboostPreCompKBytesPerSecond | 1.3.6.1.4.1.19746.1.12.2.1.1.2 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of pre-compressed (logical) bytes received per second | |||||||||||||||||||||
| CddboostPostCompKBytesPerSecond | 1.3.6.1.4.1.19746.1.12.2.1.1.3 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current number of pddboost local compression bytes received per second | |||||||||||||||||||||
| CddboostNetworkKBytesPerSecond | 1.3.6.1.4.1.19746.1.12.2.1.1.4 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of physical network bytes received per second | |||||||||||||||||||||
| CddboostReadKBytesPerSecond | 1.3.6.1.4.1.19746.1.12.2.1.1.5 | KBytesPerSecond | RO | ||||||||||||||||||
column · KBytesPerSecond · read-only · current Number of bytes read per second | |||||||||||||||||||||
| CddboostStatsBackupConn | 1.3.6.1.4.1.19746.1.12.2.1.1.6 | Counter64 | RO | ||||||||||||||||||
column · Counter64 · read-only · current Number of backup connections | |||||||||||||||||||||
| CddboostStatsRestoreConn | 1.3.6.1.4.1.19746.1.12.2.1.1.7 | Counter64 | RO | ||||||||||||||||||
column · Counter64 · read-only · current Number of restore connections | |||||||||||||||||||||
| CddboostStatsImageCreatesCount | 1.3.6.1.4.1.19746.1.12.2.1.1.8 | Counter64 | RO | ||||||||||||||||||
column · Counter64 · read-only · current Number of image creates | |||||||||||||||||||||
| CddboostStatsImageCreatesErrors | 1.3.6.1.4.1.19746.1.12.2.1.1.9 | Counter64 | RO | ||||||||||||||||||
column · Counter64 · read-only · current Number of image creates errors | |||||||||||||||||||||
| CddboostStatsImageDeletesCount | 1.3.6.1.4.1.19746.1.12.2.1.1.10 | Counter64 | RO | ||||||||||||||||||
column · Counter64 · read-only · current Number of image deletes | |||||||||||||||||||||
| CddboostStatsImageDeletesErrors | 1.3.6.1.4.1.19746.1.12.2.1.1.11 | Counter64 | RO | ||||||||||||||||||
column · Counter64 · read-only · current Number of image deletes errors | |||||||||||||||||||||
| CddboostStatsPrecompBytesReceived | 1.3.6.1.4.1.19746.1.12.2.1.1.12 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Number of pre-compressed (logical) bytes received | |||||||||||||||||||||
| CddboostStatsBytesAfterFiltering | 1.3.6.1.4.1.19746.1.12.2.1.1.13 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Number of bytes after filtering | |||||||||||||||||||||
| CddboostStatsBytesAfterLc | 1.3.6.1.4.1.19746.1.12.2.1.1.14 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Number of bytes after local compression | |||||||||||||||||||||
| CddboostStatsNetworkBytesReceived | 1.3.6.1.4.1.19746.1.12.2.1.1.15 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Number of network bytes received | |||||||||||||||||||||
| CddboostStatsCompressionRatio | 1.3.6.1.4.1.19746.1.12.2.1.1.16 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current Compression ratio | |||||||||||||||||||||
| CddboostStatsTotalBytesReadCount | 1.3.6.1.4.1.19746.1.12.2.1.1.17 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Total bytes read count | |||||||||||||||||||||
| CddboostStatsTotalBytesReadErrors | 1.3.6.1.4.1.19746.1.12.2.1.1.18 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current Total bytes read errors | |||||||||||||||||||||
| NddboostConnections | 1.3.6.1.4.1.19746.1.12.3 | ||||||||||||||||||||
| TddboostConnectionsTable | 1.3.6.1.4.1.19746.1.12.3.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST connections table information for DDBOOST Client Connections | |||||||||||||||||||||
| RddboostConnectionsEntry | 1.3.6.1.4.1.19746.1.12.3.1.1 | NA | |||||||||||||||||||
| CddboostConnectionsIndex | 1.3.6.1.4.1.19746.1.12.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current ddboost connections Table index | |||||||||||||||||||||
| CddboostInterface | 1.3.6.1.4.1.19746.1.12.3.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current DDboost Interface Name | |||||||||||||||||||||
| CddboostifGroupMember | 1.3.6.1.4.1.19746.1.12.3.1.1.3 | DDMibTableEnabledTC | RO | ||||||||||||||||||
column · DDMibTableEnabledTC · read-only · current If Member of ifGroup | |||||||||||||||||||||
| CddboostBackupConnections | 1.3.6.1.4.1.19746.1.12.3.1.1.4 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost backup connections | |||||||||||||||||||||
| CddboostRestoreConnections | 1.3.6.1.4.1.19746.1.12.3.1.1.5 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost Restore connections | |||||||||||||||||||||
| CddboostControlConnections | 1.3.6.1.4.1.19746.1.12.3.1.1.6 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost control connections | |||||||||||||||||||||
| CddboostTotalConnections | 1.3.6.1.4.1.19746.1.12.3.1.1.7 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost Total connections | |||||||||||||||||||||
| NddboostStorageUnit | 1.3.6.1.4.1.19746.1.12.4 | ||||||||||||||||||||
| TddboostStorageUnitTable | 1.3.6.1.4.1.19746.1.12.4.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST StorageUnit table information for DDBOOST Storage Units | |||||||||||||||||||||
| RddboostStorageUnitEntry | 1.3.6.1.4.1.19746.1.12.4.1.1 | NA | |||||||||||||||||||
| CddboostStorageUnitIndex | 1.3.6.1.4.1.19746.1.12.4.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current ddboost StorageUnit Table index | |||||||||||||||||||||
| CddboostStorageUnitName | 1.3.6.1.4.1.19746.1.12.4.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current DDboost Storage Unit Name | |||||||||||||||||||||
| CddboostStorageUnitBytes | 1.3.6.1.4.1.19746.1.12.4.1.1.3 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost Storage Unit Original MiB. | |||||||||||||||||||||
| CddboostStorageUnitGlobalComp | 1.3.6.1.4.1.19746.1.12.4.1.1.4 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost Storage Unit Globally Compressed MiB. | |||||||||||||||||||||
| CddboostStorageUnitLocalComp | 1.3.6.1.4.1.19746.1.12.4.1.1.5 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost Storage Unit Locally Compressed MiB. | |||||||||||||||||||||
| CddboostStorageUnitMetaData | 1.3.6.1.4.1.19746.1.12.4.1.1.6 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost Storage Unit Meta Data MiB. | |||||||||||||||||||||
| CddboostStorageUnitStatus | 1.3.6.1.4.1.19746.1.12.4.1.1.7 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current DDboost Storage Unit Status. | |||||||||||||||||||||
| CddboostStorageUnitPreComp | 1.3.6.1.4.1.19746.1.12.4.1.1.8 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current DDboost Storage Unit Pre-Compression Rate. | |||||||||||||||||||||
| CddboostStorageUnitUser | 1.3.6.1.4.1.19746.1.12.4.1.1.9 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current The User of the DDboost Storage Unit. | |||||||||||||||||||||
| CddboostStorageUnitReportPhysicalSize | 1.3.6.1.4.1.19746.1.12.4.1.1.10 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current DDboost Storage Unit Report Physical Size. | |||||||||||||||||||||
| NddboostFileReplicationStats | 1.3.6.1.4.1.19746.1.12.5 | ||||||||||||||||||||
| TddboostFileReplicationStatsTable | 1.3.6.1.4.1.19746.1.12.5.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST FileReplicationStats table contains information for File Replication Stats | |||||||||||||||||||||
| RddboostFileReplicationStatsEntry | 1.3.6.1.4.1.19746.1.12.5.1.1 | NA | |||||||||||||||||||
row · not-accessible · current ddboostFileReplicationStatsTable Row Entry | |||||||||||||||||||||
| CddboostFileReplStatsIndex | 1.3.6.1.4.1.19746.1.12.5.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current ddboost FileReplicationStats Table index | |||||||||||||||||||||
| CddboostFileReplStatsDirection | 1.3.6.1.4.1.19746.1.12.5.1.1.2 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current DDboost File Replication Direction | |||||||||||||||||||||
| CddboostFileReplStatsNetworkSent | 1.3.6.1.4.1.19746.1.12.5.1.1.3 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File Replication Network Bytes Sent | |||||||||||||||||||||
| CddboostFileReplStatsPreCompSent | 1.3.6.1.4.1.19746.1.12.5.1.1.4 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File Replication Pre Compressed bytes sent | |||||||||||||||||||||
| CddboostFileReplStatsFiltered | 1.3.6.1.4.1.19746.1.12.5.1.1.5 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File Replication Bytes after Filtering | |||||||||||||||||||||
| CddboostFileReplStatsLowBWOpt | 1.3.6.1.4.1.19746.1.12.5.1.1.6 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File Replication Bytes after Low Bandwidth optimization | |||||||||||||||||||||
| CddboostFileReplStatsLocalComp | 1.3.6.1.4.1.19746.1.12.5.1.1.7 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File Replication Bytes after local compression | |||||||||||||||||||||
| CddboostFileReplStatsCompRatio | 1.3.6.1.4.1.19746.1.12.5.1.1.8 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current DDboost File Replication Compressed Ratio | |||||||||||||||||||||
| NddboostFileReplicationHistory | 1.3.6.1.4.1.19746.1.12.6 | ||||||||||||||||||||
| TddboostFileReplicationHistoryTable | 1.3.6.1.4.1.19746.1.12.6.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST FileReplicationHistory table contains information for File Replication History | |||||||||||||||||||||
| RddboostFileReplicationHistoryEntry | 1.3.6.1.4.1.19746.1.12.6.1.1 | NA | |||||||||||||||||||
row · not-accessible · current ddboostFileReplicationHistoryTable Row Entry | |||||||||||||||||||||
| CddboostFileReplHistoryIndex | 1.3.6.1.4.1.19746.1.12.6.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current ddboost FileReplicationHistory Table index | |||||||||||||||||||||
| CddboostFileReplHistoryDirection | 1.3.6.1.4.1.19746.1.12.6.1.1.2 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current DDboost File ReplHistory History Direction | |||||||||||||||||||||
| CddboostFileReplHistoryNetwork | 1.3.6.1.4.1.19746.1.12.6.1.1.3 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File Replication History Network KBytes Sent | |||||||||||||||||||||
| CddboostFileReplHistoryPreComp | 1.3.6.1.4.1.19746.1.12.6.1.1.4 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File ReplHistory Pre Compressed Kbytes sent | |||||||||||||||||||||
| CddboostFileReplHistoryPostComp | 1.3.6.1.4.1.19746.1.12.6.1.1.5 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File ReplHistory Post Compressed KBytes | |||||||||||||||||||||
| CddboostFileReplHistoryLowBWOpt | 1.3.6.1.4.1.19746.1.12.6.1.1.6 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current DDBoost File ReplHistory KBytes after Low Bandwidth optimization | |||||||||||||||||||||
| CddboostFileReplHistoryErrors | 1.3.6.1.4.1.19746.1.12.6.1.1.7 | DDMibTrafficBytesTC | RO | ||||||||||||||||||
column · DDMibTrafficBytesTC · read-only · current DDBoost File ReplHistory Errors | |||||||||||||||||||||
| CddboostFileReplHistoryDate | 1.3.6.1.4.1.19746.1.12.6.1.1.8 | DDMibDateTC | RO | ||||||||||||||||||
column · DDMibDateTC · read-only · current DDboost File ReplHistory Date | |||||||||||||||||||||
| CddboostFileReplHistoryTime | 1.3.6.1.4.1.19746.1.12.6.1.1.9 | DDMibDateTC | RO | ||||||||||||||||||
column · DDMibDateTC · read-only · current DDboost File ReplHistory Time | |||||||||||||||||||||
| NddboostIfGroupConfig | 1.3.6.1.4.1.19746.1.12.7 | ||||||||||||||||||||
| TddboostIfGroupConfigTable | 1.3.6.1.4.1.19746.1.12.7.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST IfGroupConfig table information for DDBOOST ifGroup Configuration | |||||||||||||||||||||
| RddboostIfGroupConfigEntry | 1.3.6.1.4.1.19746.1.12.7.1.1 | NA | |||||||||||||||||||
| CddboostIfGroupConfigIndex | 1.3.6.1.4.1.19746.1.12.7.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current ddboost IfGroupConfig Table index | |||||||||||||||||||||
| CddboostIfGroupInterface | 1.3.6.1.4.1.19746.1.12.7.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current DDboost ifGroup Interface Name | |||||||||||||||||||||
| NddboostAccessClients | 1.3.6.1.4.1.19746.1.12.8 | ||||||||||||||||||||
| TddboostAccessClientsTable | 1.3.6.1.4.1.19746.1.12.8.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST AccessClients table information for DDBOOST Access Client Configuration | |||||||||||||||||||||
| RddboostAccessClientsEntry | 1.3.6.1.4.1.19746.1.12.8.1.1 | NA | |||||||||||||||||||
| CddboostAccessClientsIndex | 1.3.6.1.4.1.19746.1.12.8.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current ddboost AccessClients Table index | |||||||||||||||||||||
| CddboostAccessClientsName | 1.3.6.1.4.1.19746.1.12.8.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current The DDboost Access clients Name | |||||||||||||||||||||
| CddboostAccessClientsEncryStrength | 1.3.6.1.4.1.19746.1.12.8.1.1.3 | DdboostAccessClientsEncryStrengthTC | RO | ||||||||||||||||||
column · DdboostAccessClientsEncryStrengthTC · read-only · current The encryption strength that the DDboost Access client is using, possible values are none, medium and high | |||||||||||||||||||||
| CddboostAccessClientsAuthMode | 1.3.6.1.4.1.19746.1.12.8.1.1.4 | DdboostAccessClientsAuthModeTC | RO | ||||||||||||||||||
column · DdboostAccessClientsAuthModeTC · read-only · current The Authentication mode that the DDboost Access client is using, possible values are none, one-way, two-way and anonymous | |||||||||||||||||||||
| NddboostOptions | 1.3.6.1.4.1.19746.1.12.9 | ||||||||||||||||||||
| TddboostOptionsTable | 1.3.6.1.4.1.19746.1.12.9.1 | NA | |||||||||||||||||||
table · not-accessible · current DDBOOST Options table | |||||||||||||||||||||
| RddboostOptionsEntry | 1.3.6.1.4.1.19746.1.12.9.1.1 | NA | |||||||||||||||||||
| CddboostOptionsIndex | 1.3.6.1.4.1.19746.1.12.9.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current ddboost Option Table index | |||||||||||||||||||||
| CddboostOptionsName | 1.3.6.1.4.1.19746.1.12.9.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current DDboost Option Value Name | |||||||||||||||||||||
| CddboostOptionsStatus | 1.3.6.1.4.1.19746.1.12.9.1.1.3 | DDMibStatusTC | RO | ||||||||||||||||||
column · DDMibStatusTC · read-only · current DDboost Option Status Enabled/Disabled | |||||||||||||||||||||
| NddboostFileReplicationPerformance | 1.3.6.1.4.1.19746.1.12.10 | ||||||||||||||||||||
| SddboostFileRepliPerfInPreCompKBPerSec | 1.3.6.1.4.1.19746.1.12.10.1 | DDMibInteger32TC | RO | ||||||||||||||||||
scalar · DDMibInteger32TC · read-only · current DDBOOST File Replication Performance Inbound pre-comp kilobytes per second | |||||||||||||||||||||
| SddboostFileRepliPerfInNetworkKBPerSec | 1.3.6.1.4.1.19746.1.12.10.2 | DDMibInteger32TC | RO | ||||||||||||||||||
scalar · DDMibInteger32TC · read-only · current DDBOOST File Replication Performance Inbound network kilobytes per second | |||||||||||||||||||||
| SddboostFileRepliPerfOutPreCompKBPerSec | 1.3.6.1.4.1.19746.1.12.10.3 | DDMibInteger32TC | RO | ||||||||||||||||||
scalar · DDMibInteger32TC · read-only · current DDBOOST File Replication Performance Outbound pre-comp kilobytes per second | |||||||||||||||||||||
| SddboostFileRepliPerfOutNetworkKBPerSec | 1.3.6.1.4.1.19746.1.12.10.4 | DDMibInteger32TC | RO | ||||||||||||||||||
scalar · DDMibInteger32TC · read-only · current DDBOOST File Replication Performance Outbound network kilobytes per second | |||||||||||||||||||||
| NdataDomainSystem | 1.3.6.1.4.1.19746.1.13 | ||||||||||||||||||||
| NsystemProperties | 1.3.6.1.4.1.19746.1.13.1 | ||||||||||||||||||||
| SsystemSerialNumber | 1.3.6.1.4.1.19746.1.13.1.1 | SystemSerialNumberTC | RO | ||||||||||||||||||
scalar · SystemSerialNumberTC · read-only · current Serial Number of the System | |||||||||||||||||||||
| SsystemCurrentTime | 1.3.6.1.4.1.19746.1.13.1.2 | DDMibTimeStampTC | RO | ||||||||||||||||||
scalar · DDMibTimeStampTC · read-only · current DDR system's current time | |||||||||||||||||||||
| SsystemVersion | 1.3.6.1.4.1.19746.1.13.1.3 | DDMibVersionTC | RO | ||||||||||||||||||
scalar · DDMibVersionTC · read-only · current DD Version of the System | |||||||||||||||||||||
| SsystemModelNumber | 1.3.6.1.4.1.19746.1.13.1.4 | DDMibTableString64TC | RO | ||||||||||||||||||
scalar · DDMibTableString64TC · read-only · current Model Number of the System | |||||||||||||||||||||
| SsystemTimeZoneName | 1.3.6.1.4.1.19746.1.13.1.5 | SystemTimeZoneNameTC | RO | ||||||||||||||||||
scalar · SystemTimeZoneNameTC · read-only · current DDR system's time zone name | |||||||||||||||||||||
| SsysNotes | 1.3.6.1.4.1.19746.1.13.1.6 | SystemNotesTC | RW | ||||||||||||||||||
scalar · SystemNotesTC · read-write · current Customer defined notes associated with this DD System. | |||||||||||||||||||||
| NsystemHardware | 1.3.6.1.4.1.19746.1.13.2 | ||||||||||||||||||||
| TsystemHardwareTable | 1.3.6.1.4.1.19746.1.13.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of SystemHardwareEntry. | |||||||||||||||||||||
| RsystemHardwareEntry | 1.3.6.1.4.1.19746.1.13.2.1.1 | NA | |||||||||||||||||||
| CsystemHardwareIndex | 1.3.6.1.4.1.19746.1.13.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current System Hardware Row index | |||||||||||||||||||||
| CsystemHardwareSlot | 1.3.6.1.4.1.19746.1.13.2.1.1.2 | DDMibInteger32TC | RO | deprecated | |||||||||||||||||
column · DDMibInteger32TC · read-only · deprecated System Hardware Slot | |||||||||||||||||||||
| CsystemHardwareVendor | 1.3.6.1.4.1.19746.1.13.2.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Slot Device Vendor | |||||||||||||||||||||
| CsystemHardwareDevice | 1.3.6.1.4.1.19746.1.13.2.1.1.4 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current Slot Device | |||||||||||||||||||||
| CsystemHardwarePorts | 1.3.6.1.4.1.19746.1.13.2.1.1.5 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current Slot Ports | |||||||||||||||||||||
| CsystemHardwareSlotName | 1.3.6.1.4.1.19746.1.13.2.1.1.6 | DisplayString (SIZE (0..3)) | RO | ||||||||||||||||||
column · DisplayString (SIZE (0..3)) · read-only · current System Hardware Slot Name | |||||||||||||||||||||
| NsystemPorts | 1.3.6.1.4.1.19746.1.13.3 | ||||||||||||||||||||
| TsystemPortsTable | 1.3.6.1.4.1.19746.1.13.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of SystemPortsEntry. | |||||||||||||||||||||
| RsystemPortsEntry | 1.3.6.1.4.1.19746.1.13.3.1.1 | NA | |||||||||||||||||||
| CsystemPortsIndex | 1.3.6.1.4.1.19746.1.13.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current System Ports Row index | |||||||||||||||||||||
| CsystemPortsPort | 1.3.6.1.4.1.19746.1.13.3.1.1.2 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current System Ports Port name | |||||||||||||||||||||
| CsystemPortsConnectionType | 1.3.6.1.4.1.19746.1.13.3.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Port LinkSpeed ConnectionType | |||||||||||||||||||||
| CsystemPortsLinkSpeed | 1.3.6.1.4.1.19746.1.13.3.1.1.4 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current system Port LinkSpeed | |||||||||||||||||||||
| CsystemPortsFirmware | 1.3.6.1.4.1.19746.1.13.3.1.1.5 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current system ports firmware version | |||||||||||||||||||||
| CsystemPortsHardwareAddress | 1.3.6.1.4.1.19746.1.13.3.1.1.6 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current System Port Hardware Address. | |||||||||||||||||||||
| NsystemLicense | 1.3.6.1.4.1.19746.1.13.4 | ||||||||||||||||||||
| TsystemLicenseTable | 1.3.6.1.4.1.19746.1.13.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of SystemLicenseEntry. | |||||||||||||||||||||
| RsystemLicenseEntry | 1.3.6.1.4.1.19746.1.13.4.1.1 | NA | |||||||||||||||||||
| CsystemLicenseIndex | 1.3.6.1.4.1.19746.1.13.4.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current System License Row index | |||||||||||||||||||||
| CsystemLicenseKey | 1.3.6.1.4.1.19746.1.13.4.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current System License Key | |||||||||||||||||||||
| CsystemLicenseFeature | 1.3.6.1.4.1.19746.1.13.4.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Feature for the license | |||||||||||||||||||||
| NsystemCapacityLicense | 1.3.6.1.4.1.19746.1.13.4.2 | ||||||||||||||||||||
| TsystemCapacityLicenseTable | 1.3.6.1.4.1.19746.1.13.4.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of systemCapacityLicenseEntry. | |||||||||||||||||||||
| RsystemCapacityLicenseEntry | 1.3.6.1.4.1.19746.1.13.4.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current systemCapacityLicenseTable Row Description | |||||||||||||||||||||
| CsystemCapacityLicenseIndex | 1.3.6.1.4.1.19746.1.13.4.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current systemCapacity License Row index | |||||||||||||||||||||
| CsystemCapacityLicenseKey | 1.3.6.1.4.1.19746.1.13.4.2.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current systemCapacity License Key | |||||||||||||||||||||
| CsystemCapacityLicenseFeature | 1.3.6.1.4.1.19746.1.13.4.2.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Capacity Feature for the license | |||||||||||||||||||||
| CsystemCapacityLicenseModel | 1.3.6.1.4.1.19746.1.13.4.2.1.1.4 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current Model for Feature of the license | |||||||||||||||||||||
| CsystemCapacityLicenseCapacity | 1.3.6.1.4.1.19746.1.13.4.2.1.1.5 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current Capacity of the model | |||||||||||||||||||||
| NsystemUser | 1.3.6.1.4.1.19746.1.13.5 | ||||||||||||||||||||
| TsystemUserTable | 1.3.6.1.4.1.19746.1.13.5.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of SystemUsers. | |||||||||||||||||||||
| RsystemUserEntry | 1.3.6.1.4.1.19746.1.13.5.1.1 | NA | |||||||||||||||||||
| CsystemUserIndex | 1.3.6.1.4.1.19746.1.13.5.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current SystemUser Row index | |||||||||||||||||||||
| CsystemUserName | 1.3.6.1.4.1.19746.1.13.5.1.1.2 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current SystemUser Name | |||||||||||||||||||||
| CsystemUserUID | 1.3.6.1.4.1.19746.1.13.5.1.1.3 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current SystemUser UID | |||||||||||||||||||||
| CsystemUserRole | 1.3.6.1.4.1.19746.1.13.5.1.1.4 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current SystemUser Role | |||||||||||||||||||||
| CsystemUserStatus | 1.3.6.1.4.1.19746.1.13.5.1.1.5 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current SystemUsers Status | |||||||||||||||||||||
| TsystemActiveUserTable | 1.3.6.1.4.1.19746.1.13.5.2 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of SystemActiveUsers. | |||||||||||||||||||||
| RsystemActiveUserEntry | 1.3.6.1.4.1.19746.1.13.5.2.1 | NA | |||||||||||||||||||
| CsystemActiveUserIndex | 1.3.6.1.4.1.19746.1.13.5.2.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current SystemActiveUser Row index | |||||||||||||||||||||
| CsystemActiveUserName | 1.3.6.1.4.1.19746.1.13.5.2.1.2 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current SystemActiveUser Name | |||||||||||||||||||||
| CsystemActiveUserIdleTime | 1.3.6.1.4.1.19746.1.13.5.2.1.3 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current SystemActiveUser idle time | |||||||||||||||||||||
| CsystemActiveUserLoginTime | 1.3.6.1.4.1.19746.1.13.5.2.1.4 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current SystemActiveUser login time | |||||||||||||||||||||
| CsystemActiveUserLoginFrom | 1.3.6.1.4.1.19746.1.13.5.2.1.5 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current SystemActiveUser login from | |||||||||||||||||||||
| CsystemActiveUserTty | 1.3.6.1.4.1.19746.1.13.5.2.1.6 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current SystemActiveUsers Tty | |||||||||||||||||||||
| Nart | 1.3.6.1.4.1.19746.1.14 | ||||||||||||||||||||
| NartConfig | 1.3.6.1.4.1.19746.1.14.1 | ||||||||||||||||||||
| TartConfigTable | 1.3.6.1.4.1.19746.1.14.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of artConfigEntry. | |||||||||||||||||||||
| RartConfigEntry | 1.3.6.1.4.1.19746.1.14.1.1.1 | NA | |||||||||||||||||||
| CartConfigIndex | 1.3.6.1.4.1.19746.1.14.1.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current art Config index | |||||||||||||||||||||
| CartConfigStatus | 1.3.6.1.4.1.19746.1.14.1.1.1.2 | DDMibTableEnabledTC | RO | ||||||||||||||||||
column · DDMibTableEnabledTC · read-only · current art Config Status | |||||||||||||||||||||
| CartConfigMigrationSchedule | 1.3.6.1.4.1.19746.1.14.1.1.1.3 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current art Config Migration Schedule | |||||||||||||||||||||
| CartConfigDefaultAge | 1.3.6.1.4.1.19746.1.14.1.1.1.4 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current art Config Default Age threshold migration policy | |||||||||||||||||||||
| CartConfigFileSystemClean | 1.3.6.1.4.1.19746.1.14.1.1.1.5 | DDMibTableEnabledTC | RO | ||||||||||||||||||
column · DDMibTableEnabledTC · read-only · current art Config file System Clean Required | |||||||||||||||||||||
| CartConfigCompression | 1.3.6.1.4.1.19746.1.14.1.1.1.6 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current art Config local compression | |||||||||||||||||||||
| NartMigrationSchedule | 1.3.6.1.4.1.19746.1.14.2 | ||||||||||||||||||||
| TartMigrationScheduleTable | 1.3.6.1.4.1.19746.1.14.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of artMigrationScheduleEntry. | |||||||||||||||||||||
| RartMigrationScheduleEntry | 1.3.6.1.4.1.19746.1.14.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current artMigrationScheduleTable Row Description | |||||||||||||||||||||
| CartMigrationScheduleIndex | 1.3.6.1.4.1.19746.1.14.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current art MigrationScheduleindex | |||||||||||||||||||||
| CartMigrationScheduleSchedule | 1.3.6.1.4.1.19746.1.14.2.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current art MigrationSchedule Schedule | |||||||||||||||||||||
| CartMigrationScheduleStatus | 1.3.6.1.4.1.19746.1.14.2.1.1.3 | DDMibStatusTC | RO | ||||||||||||||||||
column · DDMibStatusTC · read-only · current art MigrationSchedule Status | |||||||||||||||||||||
| NartMigrationPolicy | 1.3.6.1.4.1.19746.1.14.3 | ||||||||||||||||||||
| TartMigrationPolicyTable | 1.3.6.1.4.1.19746.1.14.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of artMigrationPolicyEntry. | |||||||||||||||||||||
| RartMigrationPolicyEntry | 1.3.6.1.4.1.19746.1.14.3.1.1 | NA | |||||||||||||||||||
| CartMigrationPolicyIndex | 1.3.6.1.4.1.19746.1.14.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current art MigrationPolicy index | |||||||||||||||||||||
| CartMigrationPolicyMtreeName | 1.3.6.1.4.1.19746.1.14.3.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current art MigrationPolicy Mtree Name | |||||||||||||||||||||
| CartMigrationPolicyDefaultAge | 1.3.6.1.4.1.19746.1.14.3.1.1.3 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current art MigrationPolicy Default Age | |||||||||||||||||||||
| Nmtree | 1.3.6.1.4.1.19746.1.15 | ||||||||||||||||||||
| NmtreeCompression | 1.3.6.1.4.1.19746.1.15.1 | ||||||||||||||||||||
| TmtreeCompressionTable | 1.3.6.1.4.1.19746.1.15.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of mtreeCompressionEntry. | |||||||||||||||||||||
| RmtreeCompressionEntry | 1.3.6.1.4.1.19746.1.15.1.1.1 | NA | |||||||||||||||||||
| CmtreeCompressionIndex | 1.3.6.1.4.1.19746.1.15.1.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current mtree Compression index | |||||||||||||||||||||
| CmtreeCompressionMtreePath | 1.3.6.1.4.1.19746.1.15.1.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current mtree Compression Mtree Path | |||||||||||||||||||||
| CmtreeCompressionPreCompGib | 1.3.6.1.4.1.19746.1.15.1.1.1.3 | DDMibTableSizeGibTC | RO | ||||||||||||||||||
column · DDMibTableSizeGibTC · read-only · current mtree Compression Pre comp giga bytes | |||||||||||||||||||||
| CmtreeCompressionPostCompGib | 1.3.6.1.4.1.19746.1.15.1.1.1.4 | DDMibTableSizeGibTC | RO | ||||||||||||||||||
column · DDMibTableSizeGibTC · read-only · current mtree Compression Post Comp Giga Bytes | |||||||||||||||||||||
| CmtreeCompressionGlobalCompFactor | 1.3.6.1.4.1.19746.1.15.1.1.1.5 | DDMibCompressionFactorTC | RO | ||||||||||||||||||
column · DDMibCompressionFactorTC · read-only · current mtree Compression Global Comp Factor | |||||||||||||||||||||
| CmtreeCompressionLocalCompFactor | 1.3.6.1.4.1.19746.1.15.1.1.1.6 | DDMibCompressionFactorTC | RO | ||||||||||||||||||
column · DDMibCompressionFactorTC · read-only · current mtree Compression Local Comp Factor | |||||||||||||||||||||
| CmtreeCompressionPostTotalCompFactor | 1.3.6.1.4.1.19746.1.15.1.1.1.7 | DDMibCompressionFactorTC | RO | ||||||||||||||||||
column · DDMibCompressionFactorTC · read-only · current mtree Compression Total Comp Factor | |||||||||||||||||||||
| CmtreeCompressionTimePeriod | 1.3.6.1.4.1.19746.1.15.1.1.1.8 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current mtree Compression Time Period | |||||||||||||||||||||
| NmtreeList | 1.3.6.1.4.1.19746.1.15.2 | ||||||||||||||||||||
| TmtreeListTable | 1.3.6.1.4.1.19746.1.15.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of mtreeListEntry. | |||||||||||||||||||||
| RmtreeListEntry | 1.3.6.1.4.1.19746.1.15.2.1.1 | NA | |||||||||||||||||||
| CmtreeListIndex | 1.3.6.1.4.1.19746.1.15.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current mtree List index | |||||||||||||||||||||
| CmtreeListMtreeName | 1.3.6.1.4.1.19746.1.15.2.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current mtree List Mtree Name | |||||||||||||||||||||
| CmtreeListPreCompGib | 1.3.6.1.4.1.19746.1.15.2.1.1.3 | DDMibTableSizeGibTC | RO | ||||||||||||||||||
column · DDMibTableSizeGibTC · read-only · current mtree List Pre comp giga bytes | |||||||||||||||||||||
| CmtreeListStatus | 1.3.6.1.4.1.19746.1.15.2.1.1.4 | MtreeListStatusTC | RO | ||||||||||||||||||
column · MtreeListStatusTC · read-only · current mtree List Status | |||||||||||||||||||||
| NmtreeRetentionLock | 1.3.6.1.4.1.19746.1.15.4 | ||||||||||||||||||||
| TmtreeRetentionLockTable | 1.3.6.1.4.1.19746.1.15.4.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of mtreeRetentionLockEntry. | |||||||||||||||||||||
| RmtreeRetentionLockEntry | 1.3.6.1.4.1.19746.1.15.4.1.1 | NA | |||||||||||||||||||
| CmtreeRetentionLockIndex | 1.3.6.1.4.1.19746.1.15.4.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current mtree RetentionLock index | |||||||||||||||||||||
| CmtreeRetentionLockMtreeName | 1.3.6.1.4.1.19746.1.15.4.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current mtree RetentionLock Mtree Name | |||||||||||||||||||||
| CmtreeRetentionLockStatus | 1.3.6.1.4.1.19746.1.15.4.1.1.3 | MtreeRetentionLockStatusTC | RO | ||||||||||||||||||
column · MtreeRetentionLockStatusTC · read-only · current mtree RetentionLock Status | |||||||||||||||||||||
| CmtreeRetentionLockUUID | 1.3.6.1.4.1.19746.1.15.4.1.1.4 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current mtree RetentionLock UUID | |||||||||||||||||||||
| CmtreeRetentionLockMinRetentionPeriod | 1.3.6.1.4.1.19746.1.15.4.1.1.5 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current mtree RetentionLock Minimum Retention Period | |||||||||||||||||||||
| CmtreeRetentionLockMaxRetentionPeriod | 1.3.6.1.4.1.19746.1.15.4.1.1.6 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current mtree RetentionLock Maximum Retention Period | |||||||||||||||||||||
| Nstorage | 1.3.6.1.4.1.19746.1.16 | ||||||||||||||||||||
| Nenclosure | 1.3.6.1.4.1.19746.1.17 | ||||||||||||||||||||
| NenclosureList | 1.3.6.1.4.1.19746.1.17.1 | ||||||||||||||||||||
| TenclosureListTable | 1.3.6.1.4.1.19746.1.17.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of EnclosureListEntry. | |||||||||||||||||||||
| RenclosureListEntry | 1.3.6.1.4.1.19746.1.17.1.1.1 | NA | |||||||||||||||||||
| CenclosureListIndex | 1.3.6.1.4.1.19746.1.17.1.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current enclosure List Row index | |||||||||||||||||||||
| CenclosureListNum | 1.3.6.1.4.1.19746.1.17.1.1.1.2 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current enclosure Number | |||||||||||||||||||||
| CenclosureListModel | 1.3.6.1.4.1.19746.1.17.1.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current enclosure model | |||||||||||||||||||||
| CenclosureListSerialNum | 1.3.6.1.4.1.19746.1.17.1.1.1.4 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current enclosure serial number | |||||||||||||||||||||
| CenclosureListOemName | 1.3.6.1.4.1.19746.1.17.1.1.1.5 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current enclosure oem name | |||||||||||||||||||||
| CenclosureListOemValue | 1.3.6.1.4.1.19746.1.17.1.1.1.6 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current enclosure oem value | |||||||||||||||||||||
| CenclosureListCapacity | 1.3.6.1.4.1.19746.1.17.1.1.1.7 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current enclosure Capacity | |||||||||||||||||||||
| NenclosurePack | 1.3.6.1.4.1.19746.1.17.2 | ||||||||||||||||||||
| TenclosurePackTable | 1.3.6.1.4.1.19746.1.17.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of EnclosurePackEntry. | |||||||||||||||||||||
| RenclosurePackEntry | 1.3.6.1.4.1.19746.1.17.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current enclosure Pack Row Description | |||||||||||||||||||||
| CenclosurePackID | 1.3.6.1.4.1.19746.1.17.2.1.1.1 | DDMibTableIndexTC | RO | ||||||||||||||||||
column · DDMibTableIndexTC · read-only · current Pack information for the enclosure. Applicable to enclosures with packs such as ES60, and not for ES20 or ES30. | |||||||||||||||||||||
| Nnetwork | 1.3.6.1.4.1.19746.1.18 | ||||||||||||||||||||
| Ndns | 1.3.6.1.4.1.19746.1.18.1 | ||||||||||||||||||||
| TdnsTable | 1.3.6.1.4.1.19746.1.18.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of dnsEntry. | |||||||||||||||||||||
| RdnsEntry | 1.3.6.1.4.1.19746.1.18.1.1.1 | NA | |||||||||||||||||||
| CdnsIndex | 1.3.6.1.4.1.19746.1.18.1.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current DNS Table Row index | |||||||||||||||||||||
| CdnsServer | 1.3.6.1.4.1.19746.1.18.1.1.1.2 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current DNS Server | |||||||||||||||||||||
| NsearchDomains | 1.3.6.1.4.1.19746.1.18.2 | ||||||||||||||||||||
| TsearchDomainsTable | 1.3.6.1.4.1.19746.1.18.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of searchDomainsEntry. | |||||||||||||||||||||
| RsearchDomainsEntry | 1.3.6.1.4.1.19746.1.18.2.1.1 | NA | |||||||||||||||||||
| CsearchDomainsIndex | 1.3.6.1.4.1.19746.1.18.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current searchDomains Table Row index | |||||||||||||||||||||
| CsearchDomainsName | 1.3.6.1.4.1.19746.1.18.2.1.1.2 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current searchDomains Name | |||||||||||||||||||||
| NsnmpTrapHosts | 1.3.6.1.4.1.19746.1.18.3 | ||||||||||||||||||||
| TsnmpTrapHostsTable | 1.3.6.1.4.1.19746.1.18.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of snmp Trap Hosts. | |||||||||||||||||||||
| RsnmpTrapHostsEntry | 1.3.6.1.4.1.19746.1.18.3.1.1 | NA | |||||||||||||||||||
| CsnmpTrapHostsIndex | 1.3.6.1.4.1.19746.1.18.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current snmpTrapHosts Table Row index | |||||||||||||||||||||
| CsnmpTrapHostsName | 1.3.6.1.4.1.19746.1.18.3.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current snmp Trap Hosts Name | |||||||||||||||||||||
| CsnmpTrapHostsVersion | 1.3.6.1.4.1.19746.1.18.3.1.1.3 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current snmp Trap Hosts Version | |||||||||||||||||||||
| Nnis | 1.3.6.1.4.1.19746.1.18.4 | ||||||||||||||||||||
| SnisDomain | 1.3.6.1.4.1.19746.1.18.4.1 | DDMibTableString1024TC | RO | ||||||||||||||||||
scalar · DDMibTableString1024TC · read-only · current NIS domain | |||||||||||||||||||||
| SnisServers | 1.3.6.1.4.1.19746.1.18.4.2 | DDMibTableString1024TC | RO | ||||||||||||||||||
scalar · DDMibTableString1024TC · read-only · current NIS servers | |||||||||||||||||||||
| SnisAdminGroups | 1.3.6.1.4.1.19746.1.18.4.3 | DDMibTableString1024TC | RO | ||||||||||||||||||
scalar · DDMibTableString1024TC · read-only · current NIS admin groups | |||||||||||||||||||||
| SnisUserGroups | 1.3.6.1.4.1.19746.1.18.4.4 | DDMibTableString1024TC | RO | ||||||||||||||||||
scalar · DDMibTableString1024TC · read-only · current NIS user groups | |||||||||||||||||||||
| SnisBackupOperatorGroups | 1.3.6.1.4.1.19746.1.18.4.5 | DDMibTableString1024TC | RO | ||||||||||||||||||
scalar · DDMibTableString1024TC · read-only · current NIS backup operator groups | |||||||||||||||||||||
| SnisEnabled | 1.3.6.1.4.1.19746.1.18.4.6 | DDMibTableEnabledTC | RO | ||||||||||||||||||
scalar · DDMibTableEnabledTC · read-only · current NIS enabled or not | |||||||||||||||||||||
| SnisStatus | 1.3.6.1.4.1.19746.1.18.4.7 | DDMibTableString1024TC | RO | ||||||||||||||||||
scalar · DDMibTableString1024TC · read-only · current NIS status | |||||||||||||||||||||
| Nddms | 1.3.6.1.4.1.19746.1.19 | ||||||||||||||||||||
| NmanagedSystem | 1.3.6.1.4.1.19746.1.19.1 | ||||||||||||||||||||
| TmanagedSystemTable | 1.3.6.1.4.1.19746.1.19.1.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of managed systems. | |||||||||||||||||||||
| RmanagedSystemEntry | 1.3.6.1.4.1.19746.1.19.1.1.1 | NA | |||||||||||||||||||
| CmanagedSystemIndex | 1.3.6.1.4.1.19746.1.19.1.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current managed system Row index | |||||||||||||||||||||
| CmanagedSystemHostname | 1.3.6.1.4.1.19746.1.19.1.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current managed system hostname | |||||||||||||||||||||
| CmanagedSystemSerial | 1.3.6.1.4.1.19746.1.19.1.1.1.3 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current managed system serial number | |||||||||||||||||||||
| CmanagedSystemState | 1.3.6.1.4.1.19746.1.19.1.1.1.4 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current managed system state | |||||||||||||||||||||
| CmanagedSystemStatus | 1.3.6.1.4.1.19746.1.19.1.1.1.5 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current managed system status | |||||||||||||||||||||
| CmanagedSystemDDOSVersion | 1.3.6.1.4.1.19746.1.19.1.1.1.6 | DDMibTableString32TC | RO | ||||||||||||||||||
column · DDMibTableString32TC · read-only · current managed system DDOS version | |||||||||||||||||||||
| CmanagedSystemHDSyncTime | 1.3.6.1.4.1.19746.1.19.1.1.1.7 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current managed system historial data last sync time | |||||||||||||||||||||
| CmanagedSystemCDSyncTime | 1.3.6.1.4.1.19746.1.19.1.1.1.8 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current managed system system current data last sync time | |||||||||||||||||||||
| NtaskHistory | 1.3.6.1.4.1.19746.1.19.2 | ||||||||||||||||||||
| TtaskHistoryTable | 1.3.6.1.4.1.19746.1.19.2.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of TaskHistoryEntry. | |||||||||||||||||||||
| RtaskHistoryEntry | 1.3.6.1.4.1.19746.1.19.2.1.1 | NA | |||||||||||||||||||
| CtaskHistoryIndex | 1.3.6.1.4.1.19746.1.19.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Task History Row index | |||||||||||||||||||||
| CtaskHistoryUser | 1.3.6.1.4.1.19746.1.19.2.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task History User | |||||||||||||||||||||
| CtaskHistoryID | 1.3.6.1.4.1.19746.1.19.2.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task History ID | |||||||||||||||||||||
| CtaskHistoryParent | 1.3.6.1.4.1.19746.1.19.2.1.1.4 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task History Parent | |||||||||||||||||||||
| CtaskHistoryName | 1.3.6.1.4.1.19746.1.19.2.1.1.5 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task History Name | |||||||||||||||||||||
| CtaskHistoryState | 1.3.6.1.4.1.19746.1.19.2.1.1.6 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task History State | |||||||||||||||||||||
| CtaskHistoryStartTime | 1.3.6.1.4.1.19746.1.19.2.1.1.7 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task History Start Time | |||||||||||||||||||||
| CtaskHistoryDuration | 1.3.6.1.4.1.19746.1.19.2.1.1.8 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task History Duration | |||||||||||||||||||||
| NtaskActive | 1.3.6.1.4.1.19746.1.19.3 | ||||||||||||||||||||
| TtaskActiveTable | 1.3.6.1.4.1.19746.1.19.3.1 | NA | |||||||||||||||||||
table · not-accessible · current A table containing entries of TaskActiveEntry. | |||||||||||||||||||||
| RtaskActiveEntry | 1.3.6.1.4.1.19746.1.19.3.1.1 | NA | |||||||||||||||||||
| CtaskActiveIndex | 1.3.6.1.4.1.19746.1.19.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Task Active Row index | |||||||||||||||||||||
| CtaskActiveUser | 1.3.6.1.4.1.19746.1.19.3.1.1.2 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task Active User | |||||||||||||||||||||
| CtaskActiveID | 1.3.6.1.4.1.19746.1.19.3.1.1.3 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task Active ID | |||||||||||||||||||||
| CtaskActiveParent | 1.3.6.1.4.1.19746.1.19.3.1.1.4 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task Active Parent | |||||||||||||||||||||
| CtaskActiveName | 1.3.6.1.4.1.19746.1.19.3.1.1.5 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task Active Name | |||||||||||||||||||||
| CtaskActiveState | 1.3.6.1.4.1.19746.1.19.3.1.1.6 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task Active State | |||||||||||||||||||||
| CtaskActiveStartTime | 1.3.6.1.4.1.19746.1.19.3.1.1.7 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task Active Start Time | |||||||||||||||||||||
| CtaskActiveDuration | 1.3.6.1.4.1.19746.1.19.3.1.1.8 | DDMibTableString64TC | RO | ||||||||||||||||||
column · DDMibTableString64TC · read-only · current Task Active Duration | |||||||||||||||||||||
| Nsmt | 1.3.6.1.4.1.19746.1.20 | ||||||||||||||||||||
| NsmtProperties | 1.3.6.1.4.1.19746.1.20.1 | ||||||||||||||||||||
| SsmtStatus | 1.3.6.1.4.1.19746.1.20.1.1 | SmtStatusTC | RO | ||||||||||||||||||
scalar · SmtStatusTC · read-only · current The status of the Secure Multi-Tenancy (SMT) feature on a DD System, which enables storage consolidation for multiple tenants on the same appliance. Through this feature, data and control paths on the DD System are logically secured, isolated and confined, creating secure and isolated logical partitions for each tenant- unit within the same appliance. | |||||||||||||||||||||
| NtenantUnitList | 1.3.6.1.4.1.19746.1.20.2 | ||||||||||||||||||||
| TtenantUnitListTable | 1.3.6.1.4.1.19746.1.20.2.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the tenant-units within a DD System that has the Secure Multi-Tenancy (SMT) feature enabled. It includes the tenant-unit name, the number of tenant specific Management users that have been added, the number of Mtree(s)/ DDBoost Storage Units assigned, and whether Tenant-self-service mode is enabled. | |||||||||||||||||||||
| RtenantUnitListEntry | 1.3.6.1.4.1.19746.1.20.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current Information about a tenant-unit within a DD System.
| |||||||||||||||||||||
| CtenantUnitListIdx | 1.3.6.1.4.1.19746.1.20.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current The index of a tenant-unit (SMT management object). This index uniquely identifies the tenant-unit at a given time. | |||||||||||||||||||||
| CtenantUnitListName | 1.3.6.1.4.1.19746.1.20.2.1.1.2 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The name of a tenant-unit. A tenant-unit name consists of letters, numbers, no special characters and can have a length of 254 characters. | |||||||||||||||||||||
| CtenantUnitListNumberOfMgmtUsers | 1.3.6.1.4.1.19746.1.20.2.1.1.3 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The number of Tenant specific Management users which have been added to a tenant-unit. | |||||||||||||||||||||
| CtenantUnitListNumberOfMtrees | 1.3.6.1.4.1.19746.1.20.2.1.1.4 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The number of Mtree(s) which have been assigned to a tenant-unit. | |||||||||||||||||||||
| CtenantUnitListNumberOfDdboostStus | 1.3.6.1.4.1.19746.1.20.2.1.1.5 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The number of DDBoost Storage Units which have been assigned to a tenant-unit. | |||||||||||||||||||||
| CtenantUnitListTenantSelfServiceMode | 1.3.6.1.4.1.19746.1.20.2.1.1.6 | SmtStatusTC | RO | ||||||||||||||||||
column · SmtStatusTC · read-only · current Status of Tenant Self Service Mode. If enabled, administrative access to each tenant is allowed, so that they can monitor and configure their data protection implementation, within the bounds of their allocated objects and features. | |||||||||||||||||||||
| CtenantUnitListParentTenantName | 1.3.6.1.4.1.19746.1.20.2.1.1.7 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The tenant name that a tenant-unit is associated with. | |||||||||||||||||||||
| CtenantUnitListType | 1.3.6.1.4.1.19746.1.20.2.1.1.8 | DDMibTableString256TC | RO | ||||||||||||||||||
column · DDMibTableString256TC · read-only · current The Mtree type of a tenant-unit. | |||||||||||||||||||||
| CtenantUnitListSecurityMode | 1.3.6.1.4.1.19746.1.20.2.1.1.9 | TenantUnitSecurityModeTC | RO | ||||||||||||||||||
column · TenantUnitSecurityModeTC · read-only · current The security mode of a tenant-unit. | |||||||||||||||||||||
| CtenantUnitListNumberOfMgmtGroups | 1.3.6.1.4.1.19746.1.20.2.1.1.10 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current The number of Tenant specific Management groups which have been added to a tenant-unit. | |||||||||||||||||||||
| NtenantUnitMgmtUserList | 1.3.6.1.4.1.19746.1.20.3 | ||||||||||||||||||||
| TtenantUnitMgmtUserListTable | 1.3.6.1.4.1.19746.1.20.3.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the tenant specific management users that have been added to a tenant-unit. Such users may be limited by their role and scope to operate a limited set of operations only on the objects which are assigned-to/associated with their tenant-units. Tenant specific management users may have limited administrative and management capabilities. | |||||||||||||||||||||
| RtenantUnitMgmtUserListEntry | 1.3.6.1.4.1.19746.1.20.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current Information about the management users that have been added to a tenant-unit. | |||||||||||||||||||||
| CtenantUnitMgmtUserListUserName | 1.3.6.1.4.1.19746.1.20.3.1.1.2 | DDMibString96TC | NA | ||||||||||||||||||
column · DDMibString96TC · not-accessible · current The name of a management user which has been added to a tenant- unit. Users may be limited by their roles and may have limited administrative and management capabilities. | |||||||||||||||||||||
| CtenantUnitMgmtUserListUserRole | 1.3.6.1.4.1.19746.1.20.3.1.1.3 | TenantUnitMgmtUserListUserRoleTC | RO | ||||||||||||||||||
column · TenantUnitMgmtUserListUserRoleTC · read-only · current The role of a management user. Roles include tenant-admin and tenant-user. | |||||||||||||||||||||
| NtenantUnitMtreeList | 1.3.6.1.4.1.19746.1.20.4 | ||||||||||||||||||||
| TtenantUnitMtreeListTable | 1.3.6.1.4.1.19746.1.20.4.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the mtree(s) which have been assigned to a tenant-unit. Mtree logical quotas for soft-limit and hard-limit may be imposed on a tenant-unit and will allow provisioning space for each tenant on a DD System. Data access may be contained within the mtrees belonging to an tenant-unit. | |||||||||||||||||||||
| RtenantUnitMtreeListEntry | 1.3.6.1.4.1.19746.1.20.4.1.1 | NA | |||||||||||||||||||
row · not-accessible · current Information about an mtree associated with a tenant-unit within a DD System. | |||||||||||||||||||||
| CtenantUnitMtreeListMtreeName | 1.3.6.1.4.1.19746.1.20.4.1.1.2 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current The name of an mtree that has been assigned to a particular tenant-unit. One tenant-unit (SMT management object) may have multiple mtrees associated with it. | |||||||||||||||||||||
| NtenantUnitDdboostStuList | 1.3.6.1.4.1.19746.1.20.5 | ||||||||||||||||||||
| TtenantUnitDdboostStuListTable | 1.3.6.1.4.1.19746.1.20.5.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the DDBoost Storage Units that have been assigned to a tenant-unit. Logical quotas for soft- limit and hard-limit may be imposed on a tenant-unit and will allow provisioning space for each tenant on a DD System. Data access may be contained within the DDBoost Storage Units belonging to a tenant-unit. | |||||||||||||||||||||
| RtenantUnitDdboostStuListEntry | 1.3.6.1.4.1.19746.1.20.5.1.1 | NA | |||||||||||||||||||
row · not-accessible · current Information about a DDBoost Storage Unit associated with a tenant- unit. | |||||||||||||||||||||
| CtenantUnitDdboostStuListStuName | 1.3.6.1.4.1.19746.1.20.5.1.1.2 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current The name of a DDBoost Storage Unit associated with a tenant-unit. One tenant-unit (SMT management object) may have multiple DDBoost Storage Units associated with it. | |||||||||||||||||||||
| NtenantUnitAdminIpInfo | 1.3.6.1.4.1.19746.1.20.6 | ||||||||||||||||||||
| TtenantUnitAdminIpInfoTable | 1.3.6.1.4.1.19746.1.20.6.1 | NA | |||||||||||||||||||
table · not-accessible · current This table provides IP address related information about a tenant-unit administrator. | |||||||||||||||||||||
| RtenantUnitAdminIpInfoEntry | 1.3.6.1.4.1.19746.1.20.6.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry of this table represents one set of IP information about a tenant-unit administrator. | |||||||||||||||||||||
| CtenantUnitAdminIpInfoAddr | 1.3.6.1.4.1.19746.1.20.6.1.1.2 | DDMibString96TC | NA | ||||||||||||||||||
column · DDMibString96TC · not-accessible · current The IP address (IPv4/IPv6) of a tenant-unit administrator. | |||||||||||||||||||||
| CtenantUnitAdminIpInfoType | 1.3.6.1.4.1.19746.1.20.6.1.1.3 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current The IP addresss type of a tenant-unit administrator. Possible values: local or remote. | |||||||||||||||||||||
| NtenantInfo | 1.3.6.1.4.1.19746.1.20.7 | ||||||||||||||||||||
| TtenantInfoTable | 1.3.6.1.4.1.19746.1.20.7.1 | NA | |||||||||||||||||||
table · not-accessible · current This table provides tenant information for the Secure Multi-Tenancy (SMT) feature. | |||||||||||||||||||||
| RtenantInfoEntry | 1.3.6.1.4.1.19746.1.20.7.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry represents one instance about a tenant that is configured on DD system.
| |||||||||||||||||||||
| CtenantInfoIdx | 1.3.6.1.4.1.19746.1.20.7.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current The index into this table indentifying a particular tenant object. | |||||||||||||||||||||
| CtenantInfoTenantName | 1.3.6.1.4.1.19746.1.20.7.1.1.2 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current The name of this tenant. | |||||||||||||||||||||
| TtenantInfoTenantUnitTable | 1.3.6.1.4.1.19746.1.20.7.2 | NA | |||||||||||||||||||
table · not-accessible · current This table provides information about the tenant-unit(s) that are associated with this tenant. | |||||||||||||||||||||
| RtenantInfoTenantUnitEntry | 1.3.6.1.4.1.19746.1.20.7.2.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry represents information about one tenant-unit that is associated with a particular tenant. | |||||||||||||||||||||
| CtenantInfoTenantUnitName | 1.3.6.1.4.1.19746.1.20.7.2.1.2 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current The name of tenant-unit that is associated with this tenant. | |||||||||||||||||||||
| NtenantUnitMgmtGroupList | 1.3.6.1.4.1.19746.1.20.8 | ||||||||||||||||||||
| TtenantUnitMgmtGroupListTable | 1.3.6.1.4.1.19746.1.20.8.1 | NA | |||||||||||||||||||
table · not-accessible · current This table contains information about the tenant specific management groups that have been added to a tenant-unit. Such groups may be limited by their role and scope to operate a limited set of operations only on the objects which are assigned-to/associated with their tenant-units. Tenant specific management groups may have limited administrative and management capabilities. | |||||||||||||||||||||
| RtenantUnitMgmtGroupListEntry | 1.3.6.1.4.1.19746.1.20.8.1.1 | NA | |||||||||||||||||||
row · not-accessible · current Information about the management groups that have been added to a tenant-unit. | |||||||||||||||||||||
| CtenantUnitMgmtGroupListGroupName | 1.3.6.1.4.1.19746.1.20.8.1.1.2 | DDMibString96TC | NA | ||||||||||||||||||
column · DDMibString96TC · not-accessible · current The name of a management group which has been added to a tenant- unit. Groups may be limited by their roles and may have limited administrative and management capabilities. | |||||||||||||||||||||
| CtenantUnitMgmtGroupListGroupRole | 1.3.6.1.4.1.19746.1.20.8.1.1.3 | TenantUnitMgmtUserListUserRoleTC | RO | ||||||||||||||||||
column · TenantUnitMgmtUserListUserRoleTC · read-only · current The role of a management group. Roles include tenant-admin and tenant-group. | |||||||||||||||||||||
| CtenantUnitMgmtGroupListGroupType | 1.3.6.1.4.1.19746.1.20.8.1.1.4 | TenantUnitMgmtGroupTypeTC | RO | ||||||||||||||||||
column · TenantUnitMgmtGroupTypeTC · read-only · current The type of a management group. Types include all, local, ad, nis and ldap. | |||||||||||||||||||||
| Nquota | 1.3.6.1.4.1.19746.1.21 | ||||||||||||||||||||
| NquotaProperties | 1.3.6.1.4.1.19746.1.21.1 | ||||||||||||||||||||
| SquotaCapacityStatus | 1.3.6.1.4.1.19746.1.21.1.1 | DDStatusTC | RO | ||||||||||||||||||
scalar · DDStatusTC · read-only · current The status of the quota capacity property on a Data Domain System. If enabled quota limits are enforced and administrators can control the logical space consumed on a per-Mtree basis. | |||||||||||||||||||||
| NquotaCapacity | 1.3.6.1.4.1.19746.1.21.2 | ||||||||||||||||||||
| TquotaCapacityTable | 1.3.6.1.4.1.19746.1.21.2.1 | NA | |||||||||||||||||||
table · not-accessible · current This table lists quota capacities for Mtrees and Storage-units. It provides information such as the Mtree name, the Pre-Comp (MiB) size, Soft-Limit (MiB), and Hard-Limit (MiB). It is comprised of entries of quotaCapacityEntry. | |||||||||||||||||||||
| RquotaCapacityEntry | 1.3.6.1.4.1.19746.1.21.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry containing quota information for Mtrees and Storage-units on the DD System.
| |||||||||||||||||||||
| CquotaCapacityIndex | 1.3.6.1.4.1.19746.1.21.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current The index of an Mtree or Storage-unit. This index uniquely identifies the entry at a given time. | |||||||||||||||||||||
| CquotaCapacityMtreeName | 1.3.6.1.4.1.19746.1.21.2.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current The name of the Mtree or Storage-unit for which quota capacity information is provided. | |||||||||||||||||||||
| CquotaCapacityPreCompMiB | 1.3.6.1.4.1.19746.1.21.2.1.1.3 | DDMibTableSizeMiBTC | RO | ||||||||||||||||||
column · DDMibTableSizeMiBTC · read-only · current The Pre-Comp (MiB) size of the Mtree or Storage-unit. This is the amount of data written before compression. | |||||||||||||||||||||
| CquotaCapacitySoftLimitMiB | 1.3.6.1.4.1.19746.1.21.2.1.1.4 | DDMibTableSizeMiBTC | RO | ||||||||||||||||||
column · DDMibTableSizeMiBTC · read-only · current The Soft-Limit (MiB) quota for the Mtree or Storage-unit. Soft quotas provide only an alert when quota limits are reached, and the backup job is allowed to complete so that the administrator can take corrective actions that are convenient to the organization. | |||||||||||||||||||||
| CquotaCapacityHardLimitMiB | 1.3.6.1.4.1.19746.1.21.2.1.1.5 | DDMibTableSizeMiBTC | RO | ||||||||||||||||||
column · DDMibTableSizeMiBTC · read-only · current The Hard-Limit (MiB) quota for the Mtree or Storage-unit. Hard quotas provide a stricter enforcement model than soft quotas by failing the backup jobs or I/O when quota limits are reached. | |||||||||||||||||||||
| CquotaCapacityTenantUnit | 1.3.6.1.4.1.19746.1.21.2.1.1.6 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current The Tenant-unit to which this Mtree or Storage-unit is assigned. Tenant-units allow for secure and isolated logical partitions within an appliance and are part of the Secure Multi-Tenancy (SMT) feature. | |||||||||||||||||||||
| NhighAvailability | 1.3.6.1.4.1.19746.1.22 | ||||||||||||||||||||
| NhighAvailabilityStatus | 1.3.6.1.4.1.19746.1.22.1 | ||||||||||||||||||||
| ShaSystemName | 1.3.6.1.4.1.19746.1.22.1.1 | DDMibTableString128TC | RO | ||||||||||||||||||
scalar · DDMibTableString128TC · read-only · current High Availability System Name | |||||||||||||||||||||
| ShaSystemStatus | 1.3.6.1.4.1.19746.1.22.1.2 | HaSystemStatusTC | RO | ||||||||||||||||||
scalar · HaSystemStatusTC · read-only · current High Availability System Status | |||||||||||||||||||||
| ShaInterconnectStatus | 1.3.6.1.4.1.19746.1.22.1.3 | HaStatusTC | RO | ||||||||||||||||||
scalar · HaStatusTC · read-only · current High Availability Interconnect Status | |||||||||||||||||||||
| ShaPrimaryHeartbeatStatus | 1.3.6.1.4.1.19746.1.22.1.4 | HaStatusTC | RO | ||||||||||||||||||
scalar · HaStatusTC · read-only · current High Availability Primary Heartbeat Status | |||||||||||||||||||||
| ShaExternalLanHeartbeatStatus | 1.3.6.1.4.1.19746.1.22.1.5 | HaStatusTC | RO | ||||||||||||||||||
scalar · HaStatusTC · read-only · current High Availability External LAN Heartbeat Status | |||||||||||||||||||||
| ShaHardwareCompatibilityCheck | 1.3.6.1.4.1.19746.1.22.1.6 | HaStatusTC | RO | ||||||||||||||||||
scalar · HaStatusTC · read-only · current High Availability Hardware Compatibility Check | |||||||||||||||||||||
| ShaSoftwareVersionCheck | 1.3.6.1.4.1.19746.1.22.1.7 | HaStatusTC | RO | ||||||||||||||||||
scalar · HaStatusTC · read-only · current High Availability Software Version Check | |||||||||||||||||||||
| NhighAvailabilityNode | 1.3.6.1.4.1.19746.1.22.2 | ||||||||||||||||||||
| ThighAvailabilityNodeTable | 1.3.6.1.4.1.19746.1.22.2.1 | NA | |||||||||||||||||||
table · not-accessible · current This table provides high availability node information. | |||||||||||||||||||||
| RhighAvailabilityNodeEntry | 1.3.6.1.4.1.19746.1.22.2.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry represents one instance about a high availability node. | |||||||||||||||||||||
| ChighAvailabilityNodeIdx | 1.3.6.1.4.1.19746.1.22.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current The index into this table indentifying a particular node. | |||||||||||||||||||||
| ChighAvailabilityNodeName | 1.3.6.1.4.1.19746.1.22.2.1.1.2 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current The name of a high availability node. | |||||||||||||||||||||
| ChighAvailabilityNodeId | 1.3.6.1.4.1.19746.1.22.2.1.1.3 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current The ID of a high availability node. | |||||||||||||||||||||
| ChighAvailabilityNodeRole | 1.3.6.1.4.1.19746.1.22.2.1.1.4 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current The role of a high availability node. | |||||||||||||||||||||
| ChighAvailabilityNodeState | 1.3.6.1.4.1.19746.1.22.2.1.1.5 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current The state of a high availability node. | |||||||||||||||||||||
| ChighAvailabilityNodeHealth | 1.3.6.1.4.1.19746.1.22.2.1.1.6 | HaStatusTC | RO | ||||||||||||||||||
column · HaStatusTC · read-only · current The health of the high availability node's resources. | |||||||||||||||||||||
| NhighAvailabilityComponent | 1.3.6.1.4.1.19746.1.22.3 | ||||||||||||||||||||
| ThighAvailabilityComponentTable | 1.3.6.1.4.1.19746.1.22.3.1 | NA | |||||||||||||||||||
table · not-accessible · current This table provides high availability component information. | |||||||||||||||||||||
| RhighAvailabilityComponentEntry | 1.3.6.1.4.1.19746.1.22.3.1.1 | NA | |||||||||||||||||||
row · not-accessible · current An entry represents one instance about a high availability component. | |||||||||||||||||||||
| ChighAvailabilityComponentIdx | 1.3.6.1.4.1.19746.1.22.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current The index into this table indentifying a particular component. | |||||||||||||||||||||
| ChighAvailabilityComponentName | 1.3.6.1.4.1.19746.1.22.3.1.1.2 | DDMibTableString128TC | RO | ||||||||||||||||||
column · DDMibTableString128TC · read-only · current The name of the component. | |||||||||||||||||||||
| ChighAvailabilityComponentState | 1.3.6.1.4.1.19746.1.22.3.1.1.3 | HaStatusTC | RO | ||||||||||||||||||
column · HaStatusTC · read-only · current The status of the component. | |||||||||||||||||||||
| Nscsitarget | 1.3.6.1.4.1.19746.1.23 | ||||||||||||||||||||
| NscsitargetProperties | 1.3.6.1.4.1.19746.1.23.1 | ||||||||||||||||||||
| SscsitargetAdminState | 1.3.6.1.4.1.19746.1.23.1.1 | DDMibString96TC | RO | ||||||||||||||||||
scalar · DDMibString96TC · read-only · current Scsitarget Admin State | |||||||||||||||||||||
| SscsitargetProcessState | 1.3.6.1.4.1.19746.1.23.1.2 | DDMibString96TC | RO | ||||||||||||||||||
scalar · DDMibString96TC · read-only · current Scsitarget Process State | |||||||||||||||||||||
| NscsitargetGroup | 1.3.6.1.4.1.19746.1.23.2 | ||||||||||||||||||||
| TscsitargetGroupTable | 1.3.6.1.4.1.19746.1.23.2.1 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Group Table | |||||||||||||||||||||
| RscsitargetGroupEntry | 1.3.6.1.4.1.19746.1.23.2.1.1 | NA | |||||||||||||||||||
| CscsitargetGroupIndex | 1.3.6.1.4.1.19746.1.23.2.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Group Index | |||||||||||||||||||||
| CscsitargetGroupName | 1.3.6.1.4.1.19746.1.23.2.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Group Name | |||||||||||||||||||||
| CscsitargetGroupService | 1.3.6.1.4.1.19746.1.23.2.1.1.3 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Group Service | |||||||||||||||||||||
| CscsitargetGroupActiveState | 1.3.6.1.4.1.19746.1.23.2.1.1.4 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current Scsitarget Group Active State | |||||||||||||||||||||
| CscsitargetGroupNumInitiators | 1.3.6.1.4.1.19746.1.23.2.1.1.5 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current Scsitarget Group Number of Initiators | |||||||||||||||||||||
| CscsitargetGroupNumDevices | 1.3.6.1.4.1.19746.1.23.2.1.1.6 | DDMibInteger32TC | RO | ||||||||||||||||||
column · DDMibInteger32TC · read-only · current Scsitarget Group Number of Devices | |||||||||||||||||||||
| NscsitargetInitiator | 1.3.6.1.4.1.19746.1.23.3 | ||||||||||||||||||||
| TscsitargetInitiatorTable | 1.3.6.1.4.1.19746.1.23.3.1 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Initiator Table | |||||||||||||||||||||
| RscsitargetInitiatorEntry | 1.3.6.1.4.1.19746.1.23.3.1.1 | NA | |||||||||||||||||||
| CscsitargetInitiatorIndex | 1.3.6.1.4.1.19746.1.23.3.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Initiator Index | |||||||||||||||||||||
| CscsitargetInitiatorName | 1.3.6.1.4.1.19746.1.23.3.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Name | |||||||||||||||||||||
| CscsitargetInitiatorSystemAddress | 1.3.6.1.4.1.19746.1.23.3.1.1.3 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator System Address | |||||||||||||||||||||
| CscsitargetInitiatorGroup | 1.3.6.1.4.1.19746.1.23.3.1.1.4 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Group | |||||||||||||||||||||
| CscsitargetInitiatorService | 1.3.6.1.4.1.19746.1.23.3.1.1.5 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Service | |||||||||||||||||||||
| CscsitargetInitiatorAddressMethod | 1.3.6.1.4.1.19746.1.23.3.1.1.6 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Address Method | |||||||||||||||||||||
| CscsitargetInitiatorTransport | 1.3.6.1.4.1.19746.1.23.3.1.1.7 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Transport | |||||||||||||||||||||
| CscsitargetInitiatorFcWwpn | 1.3.6.1.4.1.19746.1.23.3.1.1.8 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Fc Wwpn | |||||||||||||||||||||
| CscsitargetInitiatorFcWwnn | 1.3.6.1.4.1.19746.1.23.3.1.1.9 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Fc Wwnn | |||||||||||||||||||||
| CscsitargetInitiatorFcSymbolicPortName | 1.3.6.1.4.1.19746.1.23.3.1.1.10 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Fc Symbolic Port Name | |||||||||||||||||||||
| TscsitargetInitiatorEndpTable | 1.3.6.1.4.1.19746.1.23.3.2 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Initiator Endpoint Table | |||||||||||||||||||||
| RscsitargetInitiatorEndpEntry | 1.3.6.1.4.1.19746.1.23.3.2.1 | NA | |||||||||||||||||||
| CscsitargetInitiatorEndpIndex | 1.3.6.1.4.1.19746.1.23.3.2.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Initiator Endpoint Index | |||||||||||||||||||||
| CscsitargetInitiatorEndpInitiator | 1.3.6.1.4.1.19746.1.23.3.2.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator | |||||||||||||||||||||
| CscsitargetInitiatorEndpEndpoint | 1.3.6.1.4.1.19746.1.23.3.2.1.3 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Initiator Endpoint | |||||||||||||||||||||
| CscsitargetInitiatorEndpStatus | 1.3.6.1.4.1.19746.1.23.3.2.1.4 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current Scsitarget Initiator Endpoint Status | |||||||||||||||||||||
| NscsitargetEndpoint | 1.3.6.1.4.1.19746.1.23.4 | ||||||||||||||||||||
| TscsitargetEndpointTable | 1.3.6.1.4.1.19746.1.23.4.1 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Endpoint Table | |||||||||||||||||||||
| RscsitargetEndpointEntry | 1.3.6.1.4.1.19746.1.23.4.1.1 | NA | |||||||||||||||||||
| CscsitargetEndpointIndex | 1.3.6.1.4.1.19746.1.23.4.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Endpoint Index | |||||||||||||||||||||
| CscsitargetEndpointName | 1.3.6.1.4.1.19746.1.23.4.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Name | |||||||||||||||||||||
| CscsitargetEndpointCurrentSystemAddress | 1.3.6.1.4.1.19746.1.23.4.1.1.3 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Current System Address | |||||||||||||||||||||
| CscsitargetEndpointPrimarySystemAddress | 1.3.6.1.4.1.19746.1.23.4.1.1.4 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Primary System Address | |||||||||||||||||||||
| CscsitargetEndpointSecondarySystemAddress | 1.3.6.1.4.1.19746.1.23.4.1.1.5 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Secondary System Address | |||||||||||||||||||||
| CscsitargetEndpointEnabled | 1.3.6.1.4.1.19746.1.23.4.1.1.6 | DDStatusTC | RO | ||||||||||||||||||
column · DDStatusTC · read-only · current Scsitarget Endpoint Enabled | |||||||||||||||||||||
| CscsitargetEndpointStatus | 1.3.6.1.4.1.19746.1.23.4.1.1.7 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Status | |||||||||||||||||||||
| CscsitargetEndpointTransport | 1.3.6.1.4.1.19746.1.23.4.1.1.8 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Transport | |||||||||||||||||||||
| CscsitargetEndpointFcWwnn | 1.3.6.1.4.1.19746.1.23.4.1.1.9 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Fc Wwnn | |||||||||||||||||||||
| CscsitargetEndpointFcWwpn | 1.3.6.1.4.1.19746.1.23.4.1.1.10 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Endpoint Fc Wwpn | |||||||||||||||||||||
| NscsitargetPort | 1.3.6.1.4.1.19746.1.23.5 | ||||||||||||||||||||
| TscsitargetPortTable | 1.3.6.1.4.1.19746.1.23.5.1 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Port Table | |||||||||||||||||||||
| RscsitargetPortEntry | 1.3.6.1.4.1.19746.1.23.5.1.1 | NA | |||||||||||||||||||
| CscsitargetPortIndex | 1.3.6.1.4.1.19746.1.23.5.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Port Index | |||||||||||||||||||||
| CscsitargetPortSystemAddress | 1.3.6.1.4.1.19746.1.23.5.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port System Address | |||||||||||||||||||||
| CscsitargetPortEnabled | 1.3.6.1.4.1.19746.1.23.5.1.1.3 | DDStatusTC | RO | ||||||||||||||||||
column · DDStatusTC · read-only · current Scsitarget Port Enabled | |||||||||||||||||||||
| CscsitargetPortStatus | 1.3.6.1.4.1.19746.1.23.5.1.1.4 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Status | |||||||||||||||||||||
| CscsitargetPortTransport | 1.3.6.1.4.1.19746.1.23.5.1.1.5 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Transport | |||||||||||||||||||||
| CscsitargetPortOperationalStatus | 1.3.6.1.4.1.19746.1.23.5.1.1.6 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Operational Status | |||||||||||||||||||||
| CscsitargetPortFcNpiv | 1.3.6.1.4.1.19746.1.23.5.1.1.7 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Fc Npiv | |||||||||||||||||||||
| CscsitargetPortPortId | 1.3.6.1.4.1.19746.1.23.5.1.1.8 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Port Id | |||||||||||||||||||||
| CscsitargetPortModel | 1.3.6.1.4.1.19746.1.23.5.1.1.9 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Model | |||||||||||||||||||||
| CscsitargetPortFirmware | 1.3.6.1.4.1.19746.1.23.5.1.1.10 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Firmware | |||||||||||||||||||||
| CscsitargetPortFcBaseWwnn | 1.3.6.1.4.1.19746.1.23.5.1.1.11 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Fc Base Wwnn | |||||||||||||||||||||
| CscsitargetPortFcBaseWwpn | 1.3.6.1.4.1.19746.1.23.5.1.1.12 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Fc Base Wwpn | |||||||||||||||||||||
| CscsitargetPortFcCurrentWwnn | 1.3.6.1.4.1.19746.1.23.5.1.1.13 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Fc Current Wwnn | |||||||||||||||||||||
| CscsitargetPortFcCurrentWwpn | 1.3.6.1.4.1.19746.1.23.5.1.1.14 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Fc Current Wwpn | |||||||||||||||||||||
| CscsitargetPortFcp2Retry | 1.3.6.1.4.1.19746.1.23.5.1.1.15 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Fcp2 Retry | |||||||||||||||||||||
| CscsitargetPortConnectionType | 1.3.6.1.4.1.19746.1.23.5.1.1.16 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current scsitarget Port Connection Type | |||||||||||||||||||||
| CscsitargetPortLinkSpeed | 1.3.6.1.4.1.19746.1.23.5.1.1.17 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Link Speed | |||||||||||||||||||||
| CscsitargetPortFcTopology | 1.3.6.1.4.1.19746.1.23.5.1.1.18 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Fc Topology | |||||||||||||||||||||
| TscsitargetPortEndpTable | 1.3.6.1.4.1.19746.1.23.5.2 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Port Endpoint Table | |||||||||||||||||||||
| RscsitargetPortEndpEntry | 1.3.6.1.4.1.19746.1.23.5.2.1 | NA | |||||||||||||||||||
| CscsitargetPortEndpIndex | 1.3.6.1.4.1.19746.1.23.5.2.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Port Endpoint Index | |||||||||||||||||||||
| CscsitargetPortEndpPort | 1.3.6.1.4.1.19746.1.23.5.2.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port | |||||||||||||||||||||
| CscsitargetPortEndpEndpoint | 1.3.6.1.4.1.19746.1.23.5.2.1.3 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Endpoint | |||||||||||||||||||||
| CscsitargetPortEndpEnabled | 1.3.6.1.4.1.19746.1.23.5.2.1.4 | DDStatusTC | RO | ||||||||||||||||||
column · DDStatusTC · read-only · current Scsitarget Port Endpoint Enabled | |||||||||||||||||||||
| CscsitargetPortEndpStatus | 1.3.6.1.4.1.19746.1.23.5.2.1.5 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current Scsitarget Port Endpoint Status | |||||||||||||||||||||
| CscsitargetPortEndpCurrentInstance | 1.3.6.1.4.1.19746.1.23.5.2.1.6 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Port Endpoint Current Instance | |||||||||||||||||||||
| NscsitargetDevice | 1.3.6.1.4.1.19746.1.23.6 | ||||||||||||||||||||
| TscsitargetDeviceTable | 1.3.6.1.4.1.19746.1.23.6.1 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Device Table | |||||||||||||||||||||
| RscsitargetDeviceEntry | 1.3.6.1.4.1.19746.1.23.6.1.1 | NA | |||||||||||||||||||
| CscsitargetDeviceIndex | 1.3.6.1.4.1.19746.1.23.6.1.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Device Index | |||||||||||||||||||||
| CscsitargetDeviceName | 1.3.6.1.4.1.19746.1.23.6.1.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Name | |||||||||||||||||||||
| CscsitargetDeviceService | 1.3.6.1.4.1.19746.1.23.6.1.1.3 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Service | |||||||||||||||||||||
| CscsitargetDeviceActiveState | 1.3.6.1.4.1.19746.1.23.6.1.1.4 | DDMibString96TC | RO | ||||||||||||||||||
column · DDMibString96TC · read-only · current Scsitarget Device Active State | |||||||||||||||||||||
| CscsitargetDeviceAddress | 1.3.6.1.4.1.19746.1.23.6.1.1.5 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Address | |||||||||||||||||||||
| TscsitargetDeviceGrpTable | 1.3.6.1.4.1.19746.1.23.6.2 | NA | |||||||||||||||||||
table · not-accessible · current Scsitarget Device Group Table | |||||||||||||||||||||
| RscsitargetDeviceGrpEntry | 1.3.6.1.4.1.19746.1.23.6.2.1 | NA | |||||||||||||||||||
| CscsitargetDeviceGrpIndex | 1.3.6.1.4.1.19746.1.23.6.2.1.1 | DDMibTableIndexTC | NA | ||||||||||||||||||
column · DDMibTableIndexTC · not-accessible · current Scsitarget Device Group Index | |||||||||||||||||||||
| CscsitargetDeviceGrpDevice | 1.3.6.1.4.1.19746.1.23.6.2.1.2 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device | |||||||||||||||||||||
| CscsitargetDeviceGrpGroupName | 1.3.6.1.4.1.19746.1.23.6.2.1.3 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Group Name | |||||||||||||||||||||
| CscsitargetDeviceGrpLun | 1.3.6.1.4.1.19746.1.23.6.2.1.4 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Group Lun | |||||||||||||||||||||
| CscsitargetDeviceGrpPrimaryEndpoints | 1.3.6.1.4.1.19746.1.23.6.2.1.5 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Group Primary Endpoints | |||||||||||||||||||||
| CscsitargetDeviceGrpSecondaryEndpoints | 1.3.6.1.4.1.19746.1.23.6.2.1.6 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Group Secondary Endpoints | |||||||||||||||||||||
| CscsitargetDeviceGrpInUseEndpoints | 1.3.6.1.4.1.19746.1.23.6.2.1.7 | DDMibTableString512TC | RO | ||||||||||||||||||
column · DDMibTableString512TC · read-only · current Scsitarget Device Group In Use Endpoints | |||||||||||||||||||||
| NdataDomainMibNotifications | 1.3.6.1.4.1.19746.2 | ||||||||||||||||||||
| NdataDomainMibTraps | 1.3.6.1.4.1.19746.2.0 | ||||||||||||||||||||
| !powerSupplyFailedAlarm | 1.3.6.1.4.1.19746.2.0.1 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: Power Supply failed What to do: replace the power supply | |||||||||||||||||||||
| !systemOverheatWarningAlarm | 1.3.6.1.4.1.19746.2.0.2 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the temperature reading of one of the thermometers in the Chassis has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.
| |||||||||||||||||||||
| !systemOverheatAlertAlarm | 1.3.6.1.4.1.19746.2.0.3 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the temperature reading of one of the thermometers in the Chassis is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: check the Fan status, temperatures of the environment in which the DDR is, and other factors which may increase the system temperature.
| |||||||||||||||||||||
| !systemOverheatShutdownAlarm | 1.3.6.1.4.1.19746.2.0.4 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the temperature reading of one of the thermometers in the Chassis has reached or exceeded the 'shutdown' temperature level. The DDR will be shutdown to prevent damage to the system. The index value of the alarm indicates the thermometer index that may be looked up in the environmentals table 'temperatures' for more information about the actual thermometer reading the high value. What to do: Once the system has been brought back up, after checking for high environment temperatures or other factors which may increase the system temperature, check other environmental values, such as Fan Status, Disk Temperatures, etc...
| |||||||||||||||||||||
| !fanModuleFailedAlarm | 1.3.6.1.4.1.19746.2.0.5 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: a Fan Module in the enclosure has failed. The index of the fan is given as the index of the alarm. This same index can be looked up in the environmentals table 'fanProperies' for more information about which fan has failed. What to do: replace the fan
| |||||||||||||||||||||
| !nvramFailingAlarm | 1.3.6.1.4.1.19746.2.0.6 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the errors continue. | |||||||||||||||||||||
| !fileSystemFailedAlarm | 1.3.6.1.4.1.19746.2.0.7 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: The File System process on the DDR has had a serious problem and has had to restart. What to do: check the system logs for conditions that may be triggering the failure. Other alarms may also indicate why the File System is having problems. | |||||||||||||||||||||
| !fileSpaceMaintenanceAlarm | 1.3.6.1.4.1.19746.2.0.8 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: DDVAR File System Resource Space is running low for system maintenance activities. The system may not have enough space for the routine system activities to run without error. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system.
| |||||||||||||||||||||
| !fileSpacePreWarningAlarm | 1.3.6.1.4.1.19746.2.0.9 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: A File System Resource space is 80-85% utilized. While not critical, the space usage should be monitored. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: no action is necessary, but the file system should be monitored more closely as it grows more full. Further alarms will be sent when and if the file system space is approaching very full.
| |||||||||||||||||||||
| !fileSpaceWarningAlarm | 1.3.6.1.4.1.19746.2.0.10 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: A File System Resource space is 90% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
| |||||||||||||||||||||
| !fileSpaceSevereAlarm | 1.3.6.1.4.1.19746.2.0.11 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: A File System Resource space is 95% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is getting full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
| |||||||||||||||||||||
| !fileSpaceCriticalAlarm | 1.3.6.1.4.1.19746.2.0.12 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: A File System Resource space is 100% utilized. The index value of the alarm indicates the file system index that may be looked up in the fileSystem table 'fileSystemSpace' for more information about the actual FS that is full. What to do: Delete unneeded files, such as old log files, support bundles, core files, upgrade rpm files stored in the /ddvar file system. Consider upgrading the hardware or adding shelves to high-end units. Reducing the retention times for backup data can also help. When files are deleted from outside of the /ddvar space, filesys clean will have to be done before the space is recovered.
| |||||||||||||||||||||
| !diskFailedAlarm | 1.3.6.1.4.1.19746.2.0.14 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: some problem has been detected about the indicated disk. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk that has failed. What to do: replace the disk.
| |||||||||||||||||||||
| !diskOverheatWarningAlarm | 1.3.6.1.4.1.19746.2.0.15 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the temperature reading of the indicated disk has exceeded the 'warning' temperature level. If it continues to rise, it may eventually trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature.
| |||||||||||||||||||||
| !diskOverheatAlertAlarm | 1.3.6.1.4.1.19746.2.0.16 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the temperature reading of the indicated disk is more than halfway between the 'warning' and 'shutdown' temperature levels. If it continues to rise, it will trigger a shutdown of the DDR. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: check the disk status, temperatures of the environment in which the DDR is, and other factors which may increase the temperature. If the temperature continues stays at this level or rises, and no other disks are reading this trouble, consider 'failing' the disk, and get a replacement.
| |||||||||||||||||||||
| !diskOverheatShutdownAlarm | 1.3.6.1.4.1.19746.2.0.17 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the temperature reading of the indicated disk has surpassed the 'shutdown' temperature level. The DDR will be shutdown. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk reading the high value. What to do: Boot the DDR and monitor the status and temperatures. If the same disk has continued problems, consider 'failing' it and get a replacement disk.
| |||||||||||||||||||||
| !raidReconSevereAlarm | 1.3.6.1.4.1.19746.2.0.18 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: A raid group is MAX degraded with no reconstruction after less than 71 hours or
A disk group is degraded with none max degraded with no reconstruction. This alarm is sent
every 1 hour until 71 hours after which raidReconCriticalAlarm or raidReconCriticalShutdown
alarm is generated. This can happen due to a disk failing at run-time or boot-time.
What to do: while it is still possible that the reconstruction could succeed, the disk
should be replaced to ensure data safety. | |||||||||||||||||||||
| !raidReconCriticalAlarm | 1.3.6.1.4.1.19746.2.0.19 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can happen due to a disk failing at run-time or boot-up. What to do: the disk should be replaced to ensure data safety. | |||||||||||||||||||||
| !raidReconCriticalShutdownAlarm | 1.3.6.1.4.1.19746.2.0.20 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: Raid group is MAX degraded with no reconstruction after 71 hours. This can
happen due to a disk failing at run-time or boot-up.
What to do: the disk must be replaced. | |||||||||||||||||||||
| !raidGroupMissingAlarm | 1.3.6.1.4.1.19746.2.0.21 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: one or more raid groups are missing. What to do: disk may need replacement, or raid administration may be necessary. | |||||||||||||||||||||
| !diskNoSpareAlarm | 1.3.6.1.4.1.19746.2.0.22 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: there is no spare available for the raid group. What to do: disk may need replacement, or raid administration may be necessary. | |||||||||||||||||||||
| !diskPathAlarm | 1.3.6.1.4.1.19746.2.0.23 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: multipath configuration is experiencing a problem. The number of paths set up is less than the required number of paths. Disk index is the first disk in the enclosure with multipath. What to do: multipath disk administration may be necessary.
| |||||||||||||||||||||
| !diskSASAlarm | 1.3.6.1.4.1.19746.2.0.24 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: SAS configuration error. Maximum enclosures has been reached, or there is a topology problem. What to do: SAS configuration documentation should be consulted. administration may be necessary. | |||||||||||||||||||||
| !diskSASHBAAlarm | 1.3.6.1.4.1.19746.2.0.25 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: Unsupported multi-path setting is enabled in the hba firmware. What to do: contact Data Domain support.
| |||||||||||||||||||||
| !snapshotFullAlarm | 1.3.6.1.4.1.19746.2.0.26 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: maximum number of snapshots has been reached. What to do: expire some old snapshots to make room. | |||||||||||||||||||||
| !snapshotHWMAlarm | 1.3.6.1.4.1.19746.2.0.27 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the number of snapshots has exceeded a predefined percentage (current 90%) of the maximum. What to do: begin expiring snapshots so that the maximum is not reached. | |||||||||||||||||||||
| !clusterNodeAlarm | 1.3.6.1.4.1.19746.2.0.28 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: node is not reachable on any network interface. What to do: check status of network and wiring. if that fails, try rebooting the node. | |||||||||||||||||||||
| !clusterInterfaceAlarm | 1.3.6.1.4.1.19746.2.0.29 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: one interface of the cluster node is down. What to do: check status of network and wiring. if that fails, try rebooting the node. | |||||||||||||||||||||
| !replSyncAlarm | 1.3.6.1.4.1.19746.2.0.30 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: a replication context is disabled due to nvram loss. What to do: break replication on source and destination, then reconfigure them and run replication sync.
| |||||||||||||||||||||
| !systemStartupAlarm | 1.3.6.1.4.1.19746.2.0.31 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: system has rebooted or started. this does not indicate any abnormal activity. What to do: nothing, unless reboot was triggered by other abnormal conditions, such as temperature, fan or power problems. | |||||||||||||||||||||
| !filesysRelaunchAlarm | 1.3.6.1.4.1.19746.2.0.32 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: file system has undergone too many relaunches. it is probably unstable. What to do: consult system logs. software or hardware restart may fix the malfunction. | |||||||||||||||||||||
| !filesysDDGCFailedAlarm | 1.3.6.1.4.1.19746.2.0.33 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: DDGC cleaning process has failed. What to do: consult system logs. software or hardware restart may fix the malfunction. | |||||||||||||||||||||
| !filesysGeneralProblemAlarm | 1.3.6.1.4.1.19746.2.0.34 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: a general problem has occurred with the file system. What to do: consult system logs. software or hardware restart may fix the malfunction. | |||||||||||||||||||||
| !diskUnsupportedAlarm | 1.3.6.1.4.1.19746.2.0.35 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: the model of the disk is unsupported by current DD platform. The index value of the alarm indicates the disk index that may be looked up in the disk tables 'diskProperties', 'diskPerformance', and 'diskReliability' for more information about the actual disk. What to do: replace the disk.
| |||||||||||||||||||||
| !eventIPMIUnmanageAlarm | 1.3.6.1.4.1.19746.2.0.36 | deprecated | |||||||||||||||||||
notification · deprecated Meaning: IPMI unmanaged alert detected. What to do: check alert message | |||||||||||||||||||||
| !controllerUnreachableAlert | 1.3.6.1.4.1.19746.2.0.5002 | ||||||||||||||||||||
notification · current Description:
This is a GDA event raised by the Master controller when it fails to reach a Worker
controller for more than 5 minutes. An unreachable Worker controller implies none of the Worker
controller interfaces are pingable from the Master controller.
Action:
Check the status of network interfaces on both controllers.
Check network connectivity between the Master and Worker controller.
Make sure all cables are securely connected. | |||||||||||||||||||||
| !controllerIfaceUnreachableAlert | 1.3.6.1.4.1.19746.2.0.5003 | ||||||||||||||||||||
notification · current Description:
This is a GDA event raised by the Master controller when it fails to reach a particular
Worker controller interface for more than 5 minutes. An unreachable interface implies that
it is not pingable from its Master controller equivalent interface.
Action:
Check network interface status on both controllers.
Check network connectivity between the Master and Worker controller.
Make sure all cables are securely connected. | |||||||||||||||||||||
| !correctableECCLimitReached | 1.3.6.1.4.1.19746.2.0.5004 | ||||||||||||||||||||
notification · current Description: Single bit correctable ECC limit reached. Action: Replace the failed DIMM(s). Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !uncorrectableECCerror | 1.3.6.1.4.1.19746.2.0.5005 | ||||||||||||||||||||
notification · current Description: Multi bit uncorrectable ECC error. Action: Replace the failed DIMM(s). Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !legacyChassisTempWarning | 1.3.6.1.4.1.19746.2.0.5006 | ||||||||||||||||||||
notification · current Description:
Current temperature sensor reading exceeds warning threshold.
Action:
Monitor temperature readings. If alert persists, check ambient room temperature and for blocked air flow.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !legacyChassisTempCritical | 1.3.6.1.4.1.19746.2.0.5007 | ||||||||||||||||||||
notification · current Description:
Current temperature sensor reading exceeds critical threshold.
Action:
Check ambient room temperature and for blocked air flow.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !legacyPowerSupplyWarning | 1.3.6.1.4.1.19746.2.0.5008 | ||||||||||||||||||||
notification · current Description:
A power supply has failed, is unplugged, or absent.
Action:
Check power supply cables and LED. Replace with other working power supply.
If there are outstanding alerts for all power supplies in an enclosure, the
system must be shutdown before replacing any power supply.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !legacyFanWarning | 1.3.6.1.4.1.19746.2.0.5009 | ||||||||||||||||||||
notification · current Description:
A fan has failed.
Action:
Check for any failed fan. If failed, replace with new fan.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !powerSupplyWarning | 1.3.6.1.4.1.19746.2.0.5010 | ||||||||||||||||||||
notification · current Description:
A power supply has failed, is unplugged, or absent.
Action:
Check power supply cables and LED. Replace with other working power supply.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !fanWarning | 1.3.6.1.4.1.19746.2.0.5011 | ||||||||||||||||||||
notification · current Description:
A fan has failed or is missing.
Action:
Check for any failed or missing fan. Reseat the fan.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !voltageWarning | 1.3.6.1.4.1.19746.2.0.5012 | ||||||||||||||||||||
notification · current Description:
Voltage sensor reading exceeds warning threshold.
Action:
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !powerWarning | 1.3.6.1.4.1.19746.2.0.5013 | ||||||||||||||||||||
notification · current Description:
Current power consumption reading exceeds warning threshold.
Action:
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !correctECCWarning | 1.3.6.1.4.1.19746.2.0.5014 | ||||||||||||||||||||
notification · current Description:
Memory correctable ECC errors exceed warning threshold.
Action:
These memory errors are automatically corrected by the system.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !processorWarning | 1.3.6.1.4.1.19746.2.0.5016 | ||||||||||||||||||||
notification · current Description:
Processor status sensor alert.
Action:
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !powerUnitWarning | 1.3.6.1.4.1.19746.2.0.5017 | ||||||||||||||||||||
notification · current Description:
This event is expected after power off, power cycle, or AC power loss event.
Action:
If this alert is not expected, check power cords and AC power.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !unCorrectECCWarning | 1.3.6.1.4.1.19746.2.0.5018 | ||||||||||||||||||||
notification · current Description:
Memory uncorrectable ECC error alert.
Action:
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !chassisSensorCritical | 1.3.6.1.4.1.19746.2.0.5020 | ||||||||||||||||||||
notification · current Description:
Current sensor reading or state exceeds critical condition.
Action:
Check the specific alert message for information.
Monitor temperature readings. If alert persists, check ambient room temperature
and for blocked air flow.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !chassisTempWarning | 1.3.6.1.4.1.19746.2.0.5021 | ||||||||||||||||||||
notification · current Description:
Current temperature sensor reading exceeds warning threshold.
Action:
Monitor temperature readings. If alert persists, check ambient room temperature
and for blocked air flow.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !chassisTempCritical | 1.3.6.1.4.1.19746.2.0.5022 | ||||||||||||||||||||
notification · current Description:
Current temperature sensor reading exceeds critical threshold.
Action:
Check ambient room temperature and for blocked air flow.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !cPUFailureWarning | 1.3.6.1.4.1.19746.2.0.5023 | ||||||||||||||||||||
notification · current Description:
DDOS has detected a fault with the indicated CPU.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !legacyBMCHangCritical | 1.3.6.1.4.1.19746.2.0.5024 | ||||||||||||||||||||
notification · current Description:
While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational.
This could mask serious problems such as overheating.
Action:
Use CLI or Enterprise Manager to check fan, voltage, and power supply readings.
If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC.
Wait until all LEDS are off. Reinsert the power cables and then power the system up.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !bMCHangCritical | 1.3.6.1.4.1.19746.2.0.5025 | ||||||||||||||||||||
notification · current Description:
While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational.
This could mask serious problems such as overheating.
Action:
Use CLI or Enterprise Manager to check fan, voltage, and power supply readings.
If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC.
Wait until all LEDS are off. Reinsert the power cables and then power the system up.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !abnormalShutdown | 1.3.6.1.4.1.19746.2.0.5026 | ||||||||||||||||||||
notification · current Description:
The system has been shutdown by abnormal method, i.e. not by one of the following:
1) Via IPMI chassis control command
2) Via power button
3) Via OS shutdown
Action:
This alert is expected after loss of AC (main power) event.
If this shutdown is not expected and persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !tooManyRelaunches | 1.3.6.1.4.1.19746.2.0.5027 | ||||||||||||||||||||
notification · current Description: The filesystem has failed to restart after multiple attempts. Backup and restore services are unavailable. Action: Contact your contracted support provider or visit us online at https://support.emc.com to diagnose the failure. | |||||||||||||||||||||
| !filesystemProblem | 1.3.6.1.4.1.19746.2.0.5028 | ||||||||||||||||||||
notification · current Description: A problem is preventing the filesystem from running. This usually involves the storage being unavailable. Action: Check disk shelf cabling. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !dDFSFailedInShutdown | 1.3.6.1.4.1.19746.2.0.5030 | ||||||||||||||||||||
notification · current Description: The filesystem shut down encountered an error. This can potentially leave data in the NVRAM which would be normally flushed to the disk. Failed shutdown can leave the filesystem in a state that can prevent certain operations from being performed (i.e. system upgrade, filesys destroy, etc.) and may cause data loss. Action: Re-enable the filesystem and try shutting it down again. If the problem persists, Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !dDFSNoHeartbeat | 1.3.6.1.4.1.19746.2.0.5034 | ||||||||||||||||||||
notification · current Description: Filesystem has encountered an error and is forced to restart. Action: If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !dDFSDiedAfterReboot | 1.3.6.1.4.1.19746.2.0.5036 | ||||||||||||||||||||
notification · current Description: The filesystem failed to startup immediately after system reboot. Action: Contact your contracted support provider or visit us online at https://support.emc.com for diagnosis of the cause of failure. No other action required if filesystem successfully restarts. | |||||||||||||||||||||
| !dDFSDied | 1.3.6.1.4.1.19746.2.0.5037 | ||||||||||||||||||||
notification · current Description: The filesystem process failed and is restarting. Action: Contact your contracted support provider or visit us online at https://support.emc.com for diagnosis of the cause of failure. No other action required if filesystem successfully restarts. | |||||||||||||||||||||
| !dDFSRebooted | 1.3.6.1.4.1.19746.2.0.5038 | ||||||||||||||||||||
notification · current Description: This is just a notification alert that the system has been rebooted. Action: No action required.
| |||||||||||||||||||||
| !dDFSRebootedDisabled | 1.3.6.1.4.1.19746.2.0.5039 | ||||||||||||||||||||
notification · current Description: This is a notification alert sent out during system startup following a reboot. The system is rebooted with the filesystem in disabled state. Action: No action is required unless the intent is to have the filesystem enabled. In that case, invoke the 'filesys enable' command.
| |||||||||||||||||||||
| !indexRebuildComplete | 1.3.6.1.4.1.19746.2.0.5040 | ||||||||||||||||||||
notification · current Description:
The metadata rebuild operation that was started by support has completed. The system is ready for the next action.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com to perform the next operation on your system. | |||||||||||||||||||||
| !historicalDatabaseRecoverError | 1.3.6.1.4.1.19746.2.0.5041 | ||||||||||||||||||||
notification · current Description:
All existing historical data has been lost. Data in the historical
database is used for some system reports, but it is not required for proper
system functioning. This failure may occur during head swap processing if
recovery to create the new head primary historical database from the shelf
database files fails or historical database may be corrupted.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
to debug this problem and possibly attempt recovery of the lost historical data.
| |||||||||||||||||||||
| !historicalDatabaseBackupError | 1.3.6.1.4.1.19746.2.0.5042 | ||||||||||||||||||||
notification · current Description:
Historical database backup failed. If the primary historical
database fails without a recent backup present, some or all of the historical
data can be lost when the primary historical database is restored from its
backup and log files. Data in the historical database is used for some system
reports, but it is not required for proper system functioning.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
to help debug the problem.
| |||||||||||||||||||||
| !historicalDatabaseUpgradeError | 1.3.6.1.4.1.19746.2.0.5043 | ||||||||||||||||||||
notification · current Description:
Historical database upgrade failed during software upgrade. New historical
data fields will not be saved. Some UI reports might be unavailable, or
be missing data. Otherwise, this should not affect the system.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
to help debug the problem and upgrade the historical database. | |||||||||||||||||||||
| !historicalDatabasePruneError | 1.3.6.1.4.1.19746.2.0.5044 | ||||||||||||||||||||
notification · current Description:
Historical database pruning failed. Pruning ensures the historical database
does not consume more than its allocated disk space.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
to help debug the problem. | |||||||||||||||||||||
| !noHistoricalDatabaseError | 1.3.6.1.4.1.19746.2.0.5045 | ||||||||||||||||||||
notification · current Description:
Data in the historical database is used for some system reports,
but it is not required for proper system functioning. This failure may occur
during head swap processing if recovery to create the new head primary
historical database from the shelf database files fails or the database has
been corrupted. The system is running without historical database after failing
to create a new one.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
to debug this problem and possibly attempt recovery of the lost historical data.
| |||||||||||||||||||||
| !hDTFileTransferFailed | 1.3.6.1.4.1.19746.2.0.5046 | ||||||||||||||||||||
notification · current Description: Unable to send historical data update file to Data Domain Management Center. Action: Check DNS settings and network connection between the Data Domain System and Data Domain Management Center. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !hDTSystemError | 1.3.6.1.4.1.19746.2.0.5047 | ||||||||||||||||||||
notification · current Description: System Error occurred while sending historical data to Data Domain Management Center. Action: Check configuration and system status, messages logs for indicative problems. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !dIMMFailureAlert | 1.3.6.1.4.1.19746.2.0.5048 | ||||||||||||||||||||
notification · current Description:
DIMM failure detected. DDFS can't be enabled.
Action:
Replace the bad DIMMS. | |||||||||||||||||||||
| !memoryAlert | 1.3.6.1.4.1.19746.2.0.5049 | ||||||||||||||||||||
notification · current Description:
Current memory is less than configured. DDFS can't be enabled.
Action:
Check the DIMMS in DDR. Add new DIMMS and/or replace the bad DIMMS. | |||||||||||||||||||||
| !portPathDisabled | 1.3.6.1.4.1.19746.2.0.5050 | ||||||||||||||||||||
notification · current Description:
A path is disabled. Multipath failover will not work correctly until the port is enabled.
Action:
Verify all storage cabling is connected correctly.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !diskPathRedundancy | 1.3.6.1.4.1.19746.2.0.5051 | ||||||||||||||||||||
notification · current Description:
Since only one HBA controller has been detected, disk path redundancy is lost.
Action:
If the HBA configuration is correct, disable multipath configuration. Otherwise: 1)Use
'disk multipath status' to examine connection status; 2)Verify all storage cabling is connected
correctly; 3)Use 'enclosure' commands to verify that HBA controllers are functional.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !missingPortConnection | 1.3.6.1.4.1.19746.2.0.5052 | ||||||||||||||||||||
notification · current Description:
A port and the attached storage have disappeared.
Action:
Verify the connection and any external storage connected to the missing port. | |||||||||||||||||||||
| !missingLunPath | 1.3.6.1.4.1.19746.2.0.5053 | ||||||||||||||||||||
notification · current Description:
The number of active paths to a LUN has changed.
Action:
If this is due to reconfiguration, verify the topology and disable then re-enable
multipath monitoring to reset the monitoring. If not, verify the storage cabling and that
all paths are connected. | |||||||||||||||||||||
| !missingDiskPath | 1.3.6.1.4.1.19746.2.0.5054 | ||||||||||||||||||||
notification · current Description:
The number of active paths to a disk has decreased. Multipath redundancy has been lost
unless there are more than one connection paths.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !missingEnclosurePath | 1.3.6.1.4.1.19746.2.0.5055 | ||||||||||||||||||||
notification · current Description:
The number of active paths to a disk has decreased. Multipath redundancy has been lost
unless there are more than one connection paths.
Action:
Use 'enclosure' commands to verify that HBAs are functional.
If this condition is due to configuration change: verify the topology, and then disable and
re-enable disk multipath monitoring to reset connection counts.
If not, verify the storage cabling is connected correctly.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !nvramWarning | 1.3.6.1.4.1.19746.2.0.5059 | ||||||||||||||||||||
notification · current Description: DDFS is disabled due to a problem with the NVRAM subsystem. Action: Check for other NVRAM-related alerts and follow the action described in those alerts. | |||||||||||||||||||||
| !nvramBatteryAlert | 1.3.6.1.4.1.19746.2.0.5060 | ||||||||||||||||||||
notification · current Description: DD OS detected an NVRAM card Battery Unit hardware fault. Probable causes: 1) Battery charging is disabled, or 2) One or more batteries are not charging. Action: Run CLI command 'system show nvram' to check battery status. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !nvramErrorAlert | 1.3.6.1.4.1.19746.2.0.5061 | ||||||||||||||||||||
notification · current Description:
DD OS detected an NVRAM card fault.
Probable cause: Excessive correctable errors exceed the warning threshold number.
Action:
The NVRAM card may need to be replaced.
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !phyalert | 1.3.6.1.4.1.19746.2.0.5062 | ||||||||||||||||||||
notification · current Description:
Enclosure slot has been disabled due to continuous discovery caused by a failed drive.
Action:
Replace the failed drive.
Use 'disk rescan' command specifying the disk and enclosure id to re-enable the slot. | |||||||||||||||||||||
| !replProgressThreshholdReached | 1.3.6.1.4.1.19746.2.0.5063 | ||||||||||||||||||||
notification · current Description:
Collection replication has not made progress and there is data waiting to be replicated.
This means your replica is not up to date.
Action:
- check the 'replication status' or the GUI for errors
- check the replica filesystem
- check the network
- if problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !replNeedResync | 1.3.6.1.4.1.19746.2.0.5064 | ||||||||||||||||||||
notification · current Description:
Replication will not proceed until this context is resynced.
Action:
To re-establish replication
- Note the context information
- break the context
- reconfigure contexts on both source and destination
- resync context on the source
| |||||||||||||||||||||
| !replLogFull | 1.3.6.1.4.1.19746.2.0.5065 | ||||||||||||||||||||
notification · current Description:
No data can be written to the filesystem. Too much data remains to be replicated.
This can be caused by disabled contexts or slow replication.
When the condition is resolved, the filesystem will be writable again.
Action:
Refer to knowledge base for articles discussing ways to reduce replication lag. | |||||||||||||||||||||
| !replIncompatibleWorm | 1.3.6.1.4.1.19746.2.0.5066 | ||||||||||||||||||||
notification · current Description:
New retention-locked files detected on destination during replication resync. Resync cannot proceed.
Action:
Break the existing context and resync to a new destination. | |||||||||||||||||||||
| !replDestNotConfigured | 1.3.6.1.4.1.19746.2.0.5067 | ||||||||||||||||||||
notification · current Description:
Replication context on the destination is missing or mis-matched. Cannot initialize context.
Action:
- Check both the source and destination configured context URL pair. The context is identified by the destination URL.
- Make sure the destination has a matching configuration for this context.
| |||||||||||||||||||||
| !replLagThreshholdReached | 1.3.6.1.4.1.19746.2.0.5068 | ||||||||||||||||||||
notification · current Description:
Replication lag threshold has been exceeded.
Action:
Refer to the knowledge base on ways to resolve the replication lag. | |||||||||||||||||||||
| !sASEnclosureCheck | 1.3.6.1.4.1.19746.2.0.5069 | ||||||||||||||||||||
notification · current Description:
The number of enclosures connected to the port has exceeded the maximum supported limit.
This may cause an unexpected behavior.
Action:
Reduce the number of enclosures down to the limit for the system. | |||||||||||||||||||||
| !sASTopologyCheck | 1.3.6.1.4.1.19746.2.0.5070 | ||||||||||||||||||||
notification · current Description:
Invalid cabling has been detected. This may cause unexpected behavior.
Action:
Refer to the cabling guide. Verify the connectivity of the SAS enclosures by using command
'enclosure show topology'. | |||||||||||||||||||||
| !sASPortDisabled | 1.3.6.1.4.1.19746.2.0.5071 | ||||||||||||||||||||
notification · current Description:
Excessive errors have caused this port to be disabled. This could be caused by faulty cables or shelf controllers.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com . | |||||||||||||||||||||
| !sSLCertificateCorrupted | 1.3.6.1.4.1.19746.2.0.5072 | ||||||||||||||||||||
notification · current Description:
The SSL certificate used to establish mutual trust between Data Domain systems is broken.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !snapshotOver90Percent | 1.3.6.1.4.1.19746.2.0.5075 | ||||||||||||||||||||
notification · current Description:
Current number of snapshots for an Mtree is at 90% or more of the maximum number of snapshots allowed.
Action:
Consider expiring existing snapshots of that Mtree with the 'snapshot expire' command or
adjusting scheduled snapshot retention periods with the 'snapshot schedule modify' command. | |||||||||||||||||||||
| !snapshotLimitReached | 1.3.6.1.4.1.19746.2.0.5076 | ||||||||||||||||||||
notification · current Description:
Data Domain system has a limit on the number of existing snapshots held at once for a single Mtree.
Once this limit is reached no more snapshots can be created of that Mtree.
Action:
Consider expiring existing snapshots of that Mtree with 'snapshot expire' command to make room for newer ones. | |||||||||||||||||||||
| !sNTZMultipleIterations | 1.3.6.1.4.1.19746.2.0.5077 | ||||||||||||||||||||
notification · current Description: Indicates that sanitization will be run in multiple iterations. In the worst case this can take 15-20 days for 280 TBs. It means that the system will not run at full speed for that period of time and that GC will not be run to reclaim space. However, sanitization will also reclaim space back but it might not be as efficient as GC is. Action: Make sure that you have enough space to not run out of space and that you can wait that many days in the worst case. You should have at least 20% of physical space available. Other option is to abort sanitization, delete a bunch of files and try again. You can do this process iteratively until you do not get this alert anymore. | |||||||||||||||||||||
| !coredumpWarning | 1.3.6.1.4.1.19746.2.0.5078 | ||||||||||||||||||||
notification · current Description:
/ddvar might soon run out of space to save system core dumps.
Action:
Remove unwanted files from /ddvar to free up some space.
Lack of space can result in missing core dumps that will hamper debugging operations. | |||||||||||||||||||||
| !coredumpDisabled | 1.3.6.1.4.1.19746.2.0.5079 | ||||||||||||||||||||
notification · current Description:
Space in /ddvar is not sufficient enough for saving system core dumps.
Action:
Remove unwanted files from /ddvar to free up some space.
Lack of space can result in missing core dumps that will hamper debugging operations. | |||||||||||||||||||||
| !spaceOver80Percent | 1.3.6.1.4.1.19746.2.0.5080 | ||||||||||||||||||||
notification · current Description:
Space usage has exceeded 80% of the total capacity.
Lack of space can result in missing important logs or loss of file system functionality.
Action:
If it is in root, contact your contracted support provider or visit us online at https://support.emc.com to free up some space.
If it is in /ddvar, remove unwanted files to free up some space.
If it is in active tier, remove unwanted files and start file system cleaning or add storage.
If it is in archive tier, remove unwanted files or add more archive units to the filesystem. | |||||||||||||||||||||
| !spaceOver90Percent | 1.3.6.1.4.1.19746.2.0.5081 | ||||||||||||||||||||
notification · current Description:
Space usage has exceeded 90% of the total capacity.
Lack of space can result in missing important logs or loss of file system functionality.
Action:
If it is in root, contact your contracted support provider or visit us online at https://support.emc.com to free up some space.
If it is in /ddvar, remove unwanted files to free up some space.
If it is in active tier, remove unwanted files and start file system cleaning or add storage.
If it is in archive tier, remove unwanted files or add more archive units to the filesystem. | |||||||||||||||||||||
| !diskAccessError | 1.3.6.1.4.1.19746.2.0.5082 | ||||||||||||||||||||
notification · current Description:
A hardware fault has been detected for this drive. The drive or the cabling to it may have a problem.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !diskFailure | 1.3.6.1.4.1.19746.2.0.5083 | ||||||||||||||||||||
notification · current Description:
Unable to communicate with a disk. This disk cannot be used at this time.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !diskTemperatureWarning | 1.3.6.1.4.1.19746.2.0.5084 | ||||||||||||||||||||
notification · current Description:
The disk temperature has exceeded a specified threshold. If the temperature continues to increase,
the system could fail or the system could be shut down.
Action:
If the temperature is high due to high activity for a short period, it should return to normal in a short time.
Verify the environment is at its normal temperature. If not, correct this condition.
Check for fan failures and free air flow.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !diskTemperatureShutdown | 1.3.6.1.4.1.19746.2.0.5085 | ||||||||||||||||||||
notification · current Description:
One or more disks have exceeded the shut down temperature threshold. The system is shutting down.
Action:
Verify the environment is at its normal temperature. If not, correct this condition.
Check for fan failures and free air flow.
| |||||||||||||||||||||
| !unsupportedHardwareSpareSize | 1.3.6.1.4.1.19746.2.0.5086 | ||||||||||||||||||||
notification · current Description:
The disk capacity is too small for it to be of any use in the system.
Action:
Replace with a larger capacity disk.
| |||||||||||||||||||||
| !missingDiskGroup | 1.3.6.1.4.1.19746.2.0.5087 | ||||||||||||||||||||
notification · current Description:
One or more critical disks/LUNs are unavailable.
Action:
Make sure all storage is securely connected.
Look at alert history for any path failures.
Check for any core files, a critical layer may be unavailable.
Verify that all storage is working and recognized correctly. | |||||||||||||||||||||
| !diskGroupReconstructionNoProgress | 1.3.6.1.4.1.19746.2.0.5088 | ||||||||||||||||||||
notification · current Description:
One or more disks are failed and the RAID reconstruction is not running.
Action:
Make sure there is/are spare disk(s) in the system. | |||||||||||||||||||||
| !diskGroupReconstruction | 1.3.6.1.4.1.19746.2.0.5089 | ||||||||||||||||||||
notification · current Description:
Two or more disks are failed and the RAID protection is in critical state.
If an additional disk fails, there might be permanent loss of data.
The system will shut down if the problem is not fixed.
Action:
Make sure there is/are spare disk(s) in the system. | |||||||||||||||||||||
| !diskGroupReconstructionShutdown | 1.3.6.1.4.1.19746.2.0.5090 | ||||||||||||||||||||
notification · current Description:
Two or more disks are failed and the RAID protection is in critical state for over a
considerable period of time. If an additional disk fails, there might be permanent loss of
data. The system will shut down.
Action:
Restart the system and make sure there is/are spare disk(s) in the system. | |||||||||||||||||||||
| !diskGroupReconstructionCritical | 1.3.6.1.4.1.19746.2.0.5091 | ||||||||||||||||||||
notification · current Description:
Two or more disks are failed and the RAID protection is in critical state for over a
considerable period of time. If an additional disk fails, there might be permanent loss of
data.
Action:
Make sure there is/are spare disk(s) in the system. | |||||||||||||||||||||
| !diskUnknown | 1.3.6.1.4.1.19746.2.0.5092 | ||||||||||||||||||||
notification · current Description:
Disk is unknown.
Action:
Add disk to the system. | |||||||||||||||||||||
| !lowSpares | 1.3.6.1.4.1.19746.2.0.5094 | ||||||||||||||||||||
notification · current Description:
Not enough spare disks can be detected for this tier.
There may be failed disks or connectivity issues with disks or enclosures.
Action:
Replace any failed or absent disks. Check enclosure connectivity. | |||||||||||||||||||||
| !unsupportedConfigurationROL | 1.3.6.1.4.1.19746.2.0.5095 | ||||||||||||||||||||
notification · current Description:
Raid on LUN from 4.8 is no longer supported. Please follow instruction on how to increase
usable space in your filesystem.
Action:
1) migrate data away
2) do a filesystem destroy
3) add your LUN
4) migrate data back | |||||||||||||||||||||
| !cpismissing | 1.3.6.1.4.1.19746.2.0.5500 | ||||||||||||||||||||
notification · current Description:
An archive unit is missing which could result in failure to access files in that unit.
Action:
- check power connection of each shelf.
- check data cables of each shelf.
- if a hardware problem is found and fixed, restart the files system and verify that the archive unit is online.
- If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !containerMarkedInvalid | 1.3.6.1.4.1.19746.2.0.5501 | ||||||||||||||||||||
notification · current Description:
The restorer filesystem has detected a data integrity check failure
due to hardware/software problems. There is potential for data loss or
corruption and needs immediate attention.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !smiMrc | 1.3.6.1.4.1.19746.2.0.5502 | ||||||||||||||||||||
notification · current Description:
BIOS SMI MRC interrupt
Action:
Check if system memory size has been decreased due to a DIMM has been disabled.
If yes, replace the bad DIMM.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !nvramBatteryLowChargeAlert | 1.3.6.1.4.1.19746.2.0.5508 | ||||||||||||||||||||
notification · current Description:
The NVRAM battery is charging, but is below the threshold.
The filesystem will not start until the battery charge reaches the threshold.
Action:
Wait for the battery charge to reach threshold.
If the battery does not reach threshold within 3 hours, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !ext3NvlogDisabled | 1.3.6.1.4.1.19746.2.0.5527 | ||||||||||||||||||||
notification · current Description: DDOS RAID log is disabled due to a problem with the NVRAM subsystem. Action: Check for other NVRAM-related alerts and follow the action described in those alerts. | |||||||||||||||||||||
| !enclosureMixType | 1.3.6.1.4.1.19746.2.0.5528 | ||||||||||||||||||||
notification · current Description:
An unsupported mix of enclosure models have been detected. For example, a mixture of ES30s and ES20s.
Action:
Refer to the configuration guide for valid cabling configurations. | |||||||||||||||||||||
| !replPathTooLong | 1.3.6.1.4.1.19746.2.0.5531 | ||||||||||||||||||||
notification · current Description:
Path is too long
Action:
Shorten the path. | |||||||||||||||||||||
| !compromisedEncryptionKeys | 1.3.6.1.4.1.19746.2.0.6001 | ||||||||||||||||||||
notification · current Description: Data on disk may be at risk of disclosure. Data encrypted with the compromised keys should be re-encrypted before shipping the disks. One can get the list of compromised keys either from CLI or Enterprise Manager. Action: Start file system cleaning to re-encrypt the affected data. For extended retention systems, run space reclamation to re-encrypt affected data in the archive tier. Note, these operations will take a long time to complete. | |||||||||||||||||||||
| !newEncryptionKey | 1.3.6.1.4.1.19746.2.0.6002 | ||||||||||||||||||||
notification · current Description: Old key is still used for encrypting new data. The file system needs to be restarted to activate the new key. Action: Restart the filesystem. | |||||||||||||||||||||
| !encryptionKeyTableFull | 1.3.6.1.4.1.19746.2.0.6003 | ||||||||||||||||||||
notification · current Description:
Encryption key table is full. No new keys can be added until some keys are
deleted.
Action:
Free up key table space by deleting an unused key and then add the new key. | |||||||||||||||||||||
| !uncertifiedFirmware | 1.3.6.1.4.1.19746.2.0.6004 | ||||||||||||||||||||
notification · current Description: Firmware version is not compatible with this version of DDOS and may cause unexpected behavior. Action: The firmware must be updated as soon as possible, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !filesystemNVRAMDataLoss | 1.3.6.1.4.1.19746.2.0.6005 | ||||||||||||||||||||
notification · current Description:
Filesystem cannot be enabled because of NVRAM mismatch. This can happen because of an improper headswap or NVRAM card replacement operation.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
| |||||||||||||||||||||
| !mtreeQuotaSoftLimit | 1.3.6.1.4.1.19746.2.0.6007 | ||||||||||||||||||||
notification · current Description:
The Soft Limit Quota for this MTree has been reached. This will not affect the operation of the system and is only a warning.
If a Quota Hard Limit is set for this MTree, you are approaching that limit and operations writing data to this MTree may fail if the hard limit is reached.
Action:
To clear this alert, either raise the quota limits or reduce the data in the MTree by deleting files. | |||||||||||||||||||||
| !mtreeQuotaHardLimit | 1.3.6.1.4.1.19746.2.0.6008 | ||||||||||||||||||||
notification · current Description: The Hard Limit Quota for this MTree has been reached. No more data will be written to this MTree. If a backup operation was running, it probably failed and must be restarted after clearing this condition. Action: To clear this alert, either raise the Quota Hard Limit for this MTree, or reduce the data in the MTree by deleting files. | |||||||||||||||||||||
| !interfaceConnectivityDown | 1.3.6.1.4.1.19746.2.0.6009 | ||||||||||||||||||||
notification · current Description:
Network connectivity on this interface is down.
This interface is not pingable and cannot be used to send or receive any data.
All data transfers using this interface will fail.
Action:
Please view the Hardware->Network GUI page, or use the 'net show settings' and 'net show config' CLIs to check the current configuration.
Make sure that the cable is securely connected to both endpoints and that the interfaces on both ends are properly configured.
Otherwise the cable or network hardware could be faulty and may need to be replaced.
| |||||||||||||||||||||
| !interfaceConnectivityIntermittent | 1.3.6.1.4.1.19746.2.0.6010 | ||||||||||||||||||||
notification · current Description:
Network connectivity on this interface is intermittent. Data may not be sent or received successfully.
Data transfers using this interface may experience performance degradation or intermittent failures.
Action:
Please view the Hardware->Network GUI page, or use the 'net show settings' and 'net show config' CLIs to check the current configuration.
Make sure that the cable is securely connected to both endpoints and that the interfaces on both ends are properly configured.
Otherwise the cable or network hardware could be faulty and may need to be replaced.
If the network is configured properly and the problem still persists, contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !interfaceMisconfiguration | 1.3.6.1.4.1.19746.2.0.6011 | ||||||||||||||||||||
notification · current Description:
Network interface configuration problem detected. This may be a result of changing the NIC hardware without reconfiguring the interface.
This could indicate an unsupported configuration, network environment or hardware problem.
A misconfigured interface can potentially cause connectivity problems on subsequent reboots.
Action:
Please view the Hardware->Network GUI page, or use 'net show settings', 'net config' and 'net show hardware' to check network configuration.
Try to fix the problem by reconfiguring the interface with 'net config'.
| |||||||||||||||||||||
| !recoverFromNVRAMFailed | 1.3.6.1.4.1.19746.2.0.6013 | ||||||||||||||||||||
notification · current Description:
Due to NVRAM issues, filesystem has been disabled in order to maintain data integrity.
No backups will run until this problem is resolved.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !cleaningError | 1.3.6.1.4.1.19746.2.0.6014 | ||||||||||||||||||||
notification · current Description:
Unable to reclaim unused space and this may impact the ability to backup.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !bMCPartialHang | 1.3.6.1.4.1.19746.2.0.6015 | ||||||||||||||||||||
notification · current Description:
BMC firmware is not responsive.
Action:
Use CLI or Enterprise Manager to check fan, voltage, and power supply readings.
If the system fails to fetch the readings, gracefully shut down the system and pull out all power cables to reset BMC.
Wait until all LEDS are off. Reinsert the power cables and then power the system up.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !fileMigrationError | 1.3.6.1.4.1.19746.2.0.6016 | ||||||||||||||||||||
notification · current Description:
File migration is suspended until this problem is resolved.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !unusableHostCertificate | 1.3.6.1.4.1.19746.2.0.6017 | ||||||||||||||||||||
notification · current Description:
Enterprise Manager will not start up using the imported certificate. However, it will start up using the default self-signed certificate.
Following is the list of possible causes of this alert,
- the file system is locked
- the system passphrase is missing
- the imported certificate is corrupted
Action:
Unlock the file system if it is locked.
Enter the system passphrase if it is missing.
Delete and reimport the current host certificate if it is corrupted.
In all cases, the Enterprise Manager needs to be restarted.
If the condition persists, contact your contracted support provider or visit us online at https://support.emc.com
| |||||||||||||||||||||
| !missingHostCertificate | 1.3.6.1.4.1.19746.2.0.6018 | ||||||||||||||||||||
notification · current Description:
The imported certificate is missing. However, the Enterprise Manager will start up using the default self-signed certificate.
Action:
If you want to use your own certificate, import it again.
| |||||||||||||||||||||
| !foreignEnclosure | 1.3.6.1.4.1.19746.2.0.6019 | ||||||||||||||||||||
notification · current Description:
The enclosure is unusable by the filesystem.
Storage configuration can not be modified while a foreign device is present.
Action:
If this is expected as part of a chassis swap or chassis upgrade, proceed with
the headswap operation to make the foreign filesystem available.
Otherwise contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !interfaceConnectivityUpAndRunning | 1.3.6.1.4.1.19746.2.0.6020 | ||||||||||||||||||||
notification · current Description:
Network interface is up and running for a period of time after experiencing instability.
Action:
No action needed.
| |||||||||||||||||||||
| !tcpZeroWindowAlert | 1.3.6.1.4.1.19746.2.0.6101 | ||||||||||||||||||||
notification · current Description:
The TCP connection is active but data is not being transferred.
This may cause other communication failures.
Action:
Check the remote application that uses this TCP connection.
Check the network path between the local and remote systems.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !insecureEncryptedReplication | 1.3.6.1.4.1.19746.2.0.6102 | ||||||||||||||||||||
notification · current Description:
Encrypted replication is configured between this system and the remote host.
The remote host is running a DDOS version that does not support a fully secure communication protocol.
Unauthorized individuals may be able to intercept and decrypt the replicated data.
Action:
Upgrade the remote system to a release that supports the desired communication protocol.
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !nvramHWAlert | 1.3.6.1.4.1.19746.2.0.6504 | ||||||||||||||||||||
notification · current Description:
The NVRAM card is not in a usable state.
The file system cannot be accessed until the fault is corrected or the NVRAM card is replaced.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !nvramEnvAlert | 1.3.6.1.4.1.19746.2.0.6505 | ||||||||||||||||||||
notification · current Description:
The temperature sensor on the NVRAM card or the remote battery detected a temperature
that is higher than the warning threshold. If there are other environmental alerts,
this may indicate a cooling problem where the system is installed.
If there are no other environmental alerts, this may indicate a problem with this component.
When the temperature is reduced, this alert will clear.
Action:
Check cooling and airflow around the system unit. Remove any blockage, or ensure
the environmental systems are operating correctly, and the environment is at a normal
temperature. If there is no problem in the environment, or if only the NVRAM or
remote battery are reporting this problem, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !nvramEventHWAlert | 1.3.6.1.4.1.19746.2.0.6506 | ||||||||||||||||||||
notification · current Description:
NVRAM firmware detects an NVRAM card hardware fault.
Action:
The NVRAM card may need to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !nvramBattAlert | 1.3.6.1.4.1.19746.2.0.6507 | ||||||||||||||||||||
notification · current Description:
The remote battery for an NVRAM card is not in a usable state.
The file system cannot be accessed until the fault is corrected or the NVRAM remote battery is replaced.
Action:
Check NVRAM battery status.
Check the cables between the remote battery and the power source, and between the remote battery
and the NVRAM card. If the cables are correctly connected and the problem persists,
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !nvramCondAlert | 1.3.6.1.4.1.19746.2.0.6508 | ||||||||||||||||||||
notification · current Description:
The NVRAM battery power or charging has been set as disabled.
This condition is either the result of an explicit setting, or indicates a fault
in the NVRAM card or battery unit.
Action:
If the NVRAM battery power was explicitly disabled, enable it using
the reverse of the procedure used to disable it. If not, reboot the system.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !upgradeFailure | 1.3.6.1.4.1.19746.2.0.6509 | ||||||||||||||||||||
notification · current Description:
During the upgrade process, there was an error that requires manual intervention. The system is not usable.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !upgradeCompleted | 1.3.6.1.4.1.19746.2.0.6510 | ||||||||||||||||||||
notification · current Description:
The DD OS upgrade is completed successfully. The system will be ready to use when the filesystem is enabled.
Action:
No action required. | |||||||||||||||||||||
| !mailserverError | 1.3.6.1.4.1.19746.2.0.6511 | ||||||||||||||||||||
notification · current Description:
There is a problem communicating with the configured mail server.
The system will not be able to send out any email notifications that includes alerts, autosupports and daily summary emails.
Action:
Make sure that the mail server is configured correctly.
Verify the configured mail server by sending out a test email from the system.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !invalidNICSlot | 1.3.6.1.4.1.19746.2.0.6512 | ||||||||||||||||||||
notification · current Description:
Network interface cards must be installed in their designated slots.
The network card may not function correctly when installed in the wrong slot.
Action:
Please make sure that the Network interface card is installed in a valid slot. | |||||||||||||||||||||
| !unsupportedNIC | 1.3.6.1.4.1.19746.2.0.6513 | ||||||||||||||||||||
notification · current Description:
An unsupported network interface card is installed in the system.
Having an unsupported card installed in the system can cause unexpected errors.
Action:
Remove the card from system. | |||||||||||||||||||||
| !sASHBAFailure | 1.3.6.1.4.1.19746.2.0.6514 | ||||||||||||||||||||
notification · current Description:
Storage is no longer accessible through this HBA.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !sASHBAErrors | 1.3.6.1.4.1.19746.2.0.6515 | ||||||||||||||||||||
notification · current Description:
A SAS HBA has detected correctable errors exceeding the warning threshold.
This will reduce throughput and may indicate a failing HBA.
Action:
If this condition persists for more than 24 hours, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !unsupportedSASDevice | 1.3.6.1.4.1.19746.2.0.6516 | ||||||||||||||||||||
notification · current Description:
A SAS HBA has reported a device that is not recognized.
This device is not usable and may adversely affect the system.
Action:
Identify the device and remove it from the topology.
If you believe it is a supported device, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !fanFault | 1.3.6.1.4.1.19746.2.0.6517 | ||||||||||||||||||||
notification · current Description:
A hardware fault has been detected in an enclosure cooling fan. This may allow the enclosure to overheat.
Action:
The fan must be replaced. Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !powerSupplyInputFault | 1.3.6.1.4.1.19746.2.0.6518 | ||||||||||||||||||||
notification · current Description:
A power loss has been detected in an enclosure power supply. This can be caused by a loss of AC power to one power supply.
Action:
Check if AC main power is available to the system.
Check if power supply cables are properly connected.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com to replace the power supply. | |||||||||||||||||||||
| !powerSupplyFailure | 1.3.6.1.4.1.19746.2.0.6519 | ||||||||||||||||||||
notification · current Description:
A power loss has been detected in an enclosure power supply. This can be caused by a failure in the power supply.
Action:
Power supply needs to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !powerSupplyAbsent | 1.3.6.1.4.1.19746.2.0.6520 | ||||||||||||||||||||
notification · current Description:
An enclosure power supply is absent.
Action:
Power supply needs to be replaced. Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !unsupportedACVoltage | 1.3.6.1.4.1.19746.2.0.6521 | ||||||||||||||||||||
notification · current Description:
The power supply for this enclosure is connected to an unsupported AC voltage.
The system may operate at a reduced capacity or unexpectedly shut down.
Action:
Replace the input power with the supported voltage. | |||||||||||||||||||||
| !iOModuleFault | 1.3.6.1.4.1.19746.2.0.6522 | ||||||||||||||||||||
notification · current Description:
A fault has been detected with an I/O module and it will not function correctly.
Action:
The I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !iOModuleInserted | 1.3.6.1.4.1.19746.2.0.6523 | ||||||||||||||||||||
notification · current Description:
An I/O module has been inserted during system runtime. The I/O module will not be powered on until the system is restarted.
Action:
Restart the system to activate this module. | |||||||||||||||||||||
| !mgmtModuleFault | 1.3.6.1.4.1.19746.2.0.6524 | ||||||||||||||||||||
notification · current Description:
A fault has been detected in the management I/O module. Management functions requiring the I/O module will not work.
Action:
The management I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !dIMMFailure | 1.3.6.1.4.1.19746.2.0.6525 | ||||||||||||||||||||
notification · current Description:
A fault has been detected on a memory card. The memory may no longer be usable by the system and the system may not function with the reduced memory capacity.
Action:
The failing memory card must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !sPFault | 1.3.6.1.4.1.19746.2.0.6526 | ||||||||||||||||||||
notification · current Description:
A fault has been detected on the storage processor. The system may experience unexpected behavior.
Action:
The failed storage processor must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !chassisFailure | 1.3.6.1.4.1.19746.2.0.6527 | ||||||||||||||||||||
notification · current Description:
A fault has been detected in one of the chassis components. The system may experience unexpected behavior.
Action:
The chassis must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !forcedControllerShutdown | 1.3.6.1.4.1.19746.2.0.6528 | ||||||||||||||||||||
notification · current Description:
An environmental condition or hardware fault has been detected that may cause significant damage to the hardware or possible data loss, and the system unit is being shut down.
Action:
Check the environment, If the system environment is at a normal state, restart the system and review the alert history to determine the source of the problem.
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !systemReset | 1.3.6.1.4.1.19746.2.0.6529 | ||||||||||||||||||||
notification · current Description:
A critical failure caused the system to unexpectedly shut down.
The system was able to boot successfully either because the fault was corrected, the fault was transient, or the system was able to boot without the component causing the fault.
Action:
Review the system for earlier alerts to determine the cause of the unexpected shut down.
Check the system inventory to verify all components are configured as expected.
If this alert is issued again, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !duplicateAddressDetection | 1.3.6.1.4.1.19746.2.0.6530 | ||||||||||||||||||||
notification · current Description:
This IP address has been detected on the network. Connections to this IP address will be adversely impacted.
Action:
Make sure the local and remote systems are using different IP addresses. Clear the alert once the problem is resolved.
| |||||||||||||||||||||
| !spaceReclRestartFailed | 1.3.6.1.4.1.19746.2.0.6531 | ||||||||||||||||||||
notification · current Description:
Archive space reclamation was running before the last shutdown of the filesystem and could not be restarted automatically.
Space will not be reclaimed in the archive tier until space reclamation is restarted.
Action:
Start space reclamation. | |||||||||||||||||||||
| !spaceReclMissingUnit | 1.3.6.1.4.1.19746.2.0.6532 | ||||||||||||||||||||
notification · current Description:
Archive units are missing. Space reclamation cannot run unless all configured units are attached.
Space will not be reclaimed in the archive tier until space reclamation is restarted.
Action:
Return missing archive units to the system and start space reclamation. | |||||||||||||||||||||
| !spaceReclUnitReclaimed | 1.3.6.1.4.1.19746.2.0.6533 | ||||||||||||||||||||
notification · current Description:
All space on the archive unit has been reclaimed. This unit is available to reuse.
Action:
No action is required. | |||||||||||||||||||||
| !spaceReclError | 1.3.6.1.4.1.19746.2.0.6534 | ||||||||||||||||||||
notification · current Description:
Archive space reclamation has stopped due to the specified error.
Space will not be reclaimed in the archive tier until the error condition is resolved and space reclamation is restarted.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !enclosureHighTemp | 1.3.6.1.4.1.19746.2.0.6535 | ||||||||||||||||||||
notification · current Description:
The temperature inside the enclosure is high and has exceeded the warning threshold.If no action is taken and the temperature continue to increase, the system will shut down.
Action:
If the temperature around the system unit is within the documented operating limits and the air flow is not blocked,
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !unsupportedSystemType | 1.3.6.1.4.1.19746.2.0.6536 | ||||||||||||||||||||
notification · current Description:
An unsupported system type has been detected and needs
to be modified or replaced.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !bMCHangShutdown | 1.3.6.1.4.1.19746.2.0.6537 | ||||||||||||||||||||
notification · current Description:
While BMC is unresponsive, environmental monitoring and remote access via IPMI is not operational. This could mask serious problems such as overheating.
Action:
After the system is shut down, pull out all power cables from the controller to reset BMC.
Wait until all LEDs are off, reinsert the power cables, and then power the system up.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !expiredHostCertificate | 1.3.6.1.4.1.19746.2.0.6538 | ||||||||||||||||||||
notification · current Description:
Communication using this certificate is vulnerable to disclosure.
Action:
Replace the host certificate with a valid certificate.
| |||||||||||||||||||||
| !sCSITGTInvalidRegistry | 1.3.6.1.4.1.19746.2.0.6539 | ||||||||||||||||||||
notification · current Description:
A registry entry used in the SCSI Target system is invalid.
The SCSI Target services, including VTL, DD-BOOST FC and VDISK will be
inaccessible until this problem is resolved.
Action:
The registry entry must be corrected.
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !encryptionKeyExportFailed | 1.3.6.1.4.1.19746.2.0.6540 | ||||||||||||||||||||
notification · current Description:
The automatic export of the encryption keys failed.
This could result in encrypted data being inaccessible.
Action:
Manually export the encryption keys. | |||||||||||||||||||||
| !sSDEndOfLife | 1.3.6.1.4.1.19746.2.0.6541 | ||||||||||||||||||||
notification · current Description:
The SSD has reached end of life and could fail at any time.
The system may shut down unexpectedly if the drive is not replaced.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
| |||||||||||||||||||||
| !tapeReposition | 1.3.6.1.4.1.19746.2.0.6542 | ||||||||||||||||||||
notification · current Description:
The tape volume was adjusted to the last consistent data position during
VTL recovery. Recent pending updates to the volume may have been discarded.
Action:
Verify that any backup sent to the affected tape at the time of this alert
completed successfully. Reissue the backup if necessary. | |||||||||||||||||||||
| !multipleDiskReadErrors | 1.3.6.1.4.1.19746.2.0.6543 | ||||||||||||||||||||
notification · current Description:
There are too many disks reporting read errors in the same RAID group.
As each of these disks completes reconstruction it will be failed.
If the ongoing RAID reconstruction fails, there might be permanent loss of data.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com to determine the number of drives that need to be replaced. | |||||||||||||||||||||
| !missingCreplUnits | 1.3.6.1.4.1.19746.2.0.6544 | ||||||||||||||||||||
notification · current Description:
The collection replication destination is not in a consistent state and will not be usable until matching retention units are added to the destination.
Action:
Add the required retention units to the collection replication destination. | |||||||||||||||||||||
| !nvramBattEndOfLife | 1.3.6.1.4.1.19746.2.0.6545 | ||||||||||||||||||||
notification · current Description:
The remote battery for NVRAM us currently usable but is approaching the end of its life.
If the battery is not replaced before it reaches end of its life, the filesystem will be disabled.
Action:
To schedule a replacement, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !bMCFailure | 1.3.6.1.4.1.19746.2.0.7000 | ||||||||||||||||||||
notification · current Description:
BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will be disabled.
Action:
Shut the system down and pull out all power cables from the controller to reset BMC.
Wait until all LEDs are off, reinsert the power cables, and then power the system up.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !unsupportedDriveModel | 1.3.6.1.4.1.19746.2.0.7001 | ||||||||||||||||||||
notification · current Description:
This system only supports certain drive models.
The unsupported drives are unusable and must be replaced for proper system operation.
Action:
Identify and remove/replace the unsupported drives.
For assistance, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !driveMixType | 1.3.6.1.4.1.19746.2.0.7002 | ||||||||||||||||||||
notification · current Description:
Mixing drive types within an enclosure is not supported and may cause unexpected system behavior.
Action:
Ensure that all drives within the enclosure are of the same type.
For assistance, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !sMSUnresponsive | 1.3.6.1.4.1.19746.2.0.7500 | ||||||||||||||||||||
notification · current Description:
The System Management Service has reached the maximum number of concurrent
requests and has been unresponsive for over five minutes. This may indicate
a serious condition that may need to be addressed by support. The system is
unable to accept additional commands.
Action:
If this condition persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !nISCommFailure | 1.3.6.1.4.1.19746.2.0.7501 | ||||||||||||||||||||
notification · current Description:
Unable to query information from the NIS server.
This could be a network problem or an authentication failure with the NIS server.
This could prevent NIS servers from completing backups or restoring existing backups.
This alert will clear when communication is established with the NIS server.
Action:
Verify network connection to the NIS server and verify NIS configurations for both systems.
If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com . | |||||||||||||||||||||
| !unsupportedHardwareConfig | 1.3.6.1.4.1.19746.2.0.7502 | ||||||||||||||||||||
notification · current Description:
Unsupported virtual machine hardware configuration was detected.
This configuration may cause unexpected behavior.
Action:
Fix the hardware configuration to resolve the problem.
If problem persists, restart the system. | |||||||||||||||||||||
| !unsupportedVirtualCPU | 1.3.6.1.4.1.19746.2.0.7503 | ||||||||||||||||||||
notification · current Description:
The current number of CPU sockets and cores in the
virtual machine configuration is not valid for the
current storage capacity. The file system will not
be enabled.
Action:
Power off this virtual machine instance and change
the virtual machine configuration to match the supported values.
If you made this change to add storage capacity, you must
add the additional capacity before enabling the file system. | |||||||||||||||||||||
| !dNSUnresponsive | 1.3.6.1.4.1.19746.2.0.7504 | ||||||||||||||||||||
notification · current Description:
No DNS servers responded to a DNS query. This may be caused by a network failure or a DNS server problem.
System functions that require name address resolution will fail.
Action:
Check the network path and the DNS server to establish communication or remove the DNS entries and add host entries to the hosts table.
If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !nTPDFailed | 1.3.6.1.4.1.19746.2.0.7505 | ||||||||||||||||||||
notification · current Description: Network Time Protocol (NTP) daemon is not running. NTP daemon has detected a time difference between this system and the configured network time server (drift) greater than the configured maximum and has shut down. Action: Disable NTP. Verify time on the NTP server. Set system date/time to match the time on the NTP server. Enable NTP. If this problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !invalidEnclosureTopology | 1.3.6.1.4.1.19746.2.0.7506 | ||||||||||||||||||||
notification · current Description:
The cables connecting enclosures to the controller are not installed correctly. This can cause unpredictable system behavior. Recable the enclosures immediately.
Action:
Display the topology to identify the invalid path(s). Power down the system and cable the enclosures according to the cabling guide for your system. | |||||||||||||||||||||
| !diskPathSpeedDegraded | 1.3.6.1.4.1.19746.2.0.7507 | ||||||||||||||||||||
notification · current Description:
SAS connection speed is degraded and could reduce disk performance.
Action:
Check cable seating and replace if needed.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !targetDriverPortOffline | 1.3.6.1.4.1.19746.2.0.7508 | ||||||||||||||||||||
notification · current Description:
No connection is detected on the Fibre Channel Port.
Action:
If this port is not in use, please disable it. If port is being
used, please restore Fibre Channel Port connectivity. Alert will be cleared
when port is disabled or online. | |||||||||||||||||||||
| !targetDriverPortOnline | 1.3.6.1.4.1.19746.2.0.7509 | ||||||||||||||||||||
notification · current Description:
Fibre Channel Port is online.
Action:
No action required | |||||||||||||||||||||
| !targetDriverPortCore | 1.3.6.1.4.1.19746.2.0.7510 | ||||||||||||||||||||
notification · current Description:
An error occurred on the Fibre Channel Port that resulted in a HBA core.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com to extract and analyze the HBA core. | |||||||||||||||||||||
| !targetDriverPortMultipleCore | 1.3.6.1.4.1.19746.2.0.7511 | ||||||||||||||||||||
notification · current Description:
An error occurred on the Fibre Channel Port that caused multiple HBA core attempts. The Fibre Channel Port is disabled.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA. | |||||||||||||||||||||
| !targetDriverPortFWLoadFailed | 1.3.6.1.4.1.19746.2.0.7512 | ||||||||||||||||||||
notification · current Description:
The Fibre Channel Port is unable to load required firmware. The Fibre Channel Port is disabled.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA. | |||||||||||||||||||||
| !targetDriverPortUnreadable | 1.3.6.1.4.1.19746.2.0.7513 | ||||||||||||||||||||
notification · current Description:
Unable to access one or more resources on the HBA. The Fibre Channel Port is disabled.
Action:
Contact contact your contracted support provider or visit us online at https://support.emc.com to replace Fibre Channel HBA. | |||||||||||||||||||||
| !targetDriverPortTooManyOsc | 1.3.6.1.4.1.19746.2.0.7514 | ||||||||||||||||||||
notification · current Description:
The system has detected a Fibre Channel Port has been transitioning
between online and offline too frequently. This may cause disruption in i/o.
Action:
Please ensure stable port connectivity. Disable the port if it is not in use. | |||||||||||||||||||||
| !insufficientSpaceForEncryption | 1.3.6.1.4.1.19746.2.0.7515 | ||||||||||||||||||||
notification · current Description: Additional space is needed on the archive tier to encrypt the existing data. Free space up to 1% of data size may be required. Un-encrypted data will not get encrypted until sufficient space is available. Action: Make free space available in the archive tier by doing one or all of the following: 1. Delete any unwanted data in archive tier and run space-reclamation to reclaim free space. 2. Expand the archive unit by adding some storage, and run space-reclamation. | |||||||||||||||||||||
| !dDFSRequiresReboot | 1.3.6.1.4.1.19746.2.0.7516 | ||||||||||||||||||||
notification · current Description: File system was unable to start because an abnormal internal condition was detected. Action: Reboot the system. If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !storageUnitStreamSoftLimit | 1.3.6.1.4.1.19746.2.0.7517 | ||||||||||||||||||||
notification · current Description:
Stream soft limit quota for this storage-unit and type of stream has been exceeded.
Crossing this limit may cause reduced performance as the system hard limits are reached.
Action:
To clear this alert, configure the backup application to use fewer concurrent streams.
Otherwise, increase the soft limit quota on this storage-unit for this stream type. | |||||||||||||||||||||
| !spaceReclSuspended | 1.3.6.1.4.1.19746.2.0.7518 | ||||||||||||||||||||
notification · current Description:
Archive space reclamation has suspended due to the specified error.
Space will not be reclaimed in the archive tier until the error condition is resolved and space reclamation is resumed.
Action:
Resume space reclamation after the underlying error condition is corrected. If problem persists,
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !metadataWarningThreshold | 1.3.6.1.4.1.19746.2.0.7519 | ||||||||||||||||||||
notification · current Description:
Large amount of metadata has been created by the filesystem.
Continuing without cleaning would cause the filesystem to enter into read-only mode.
Action:
Clean the filesystem as soon as possible.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !mtreeCascadeNeedResync | 1.3.6.1.4.1.19746.2.0.7520 | ||||||||||||||||||||
notification · current Description:
This Mtree is now a cascaded source. Since this mtree already has data, this replication context requires a resync to proceed.
Action:
To re-establish replication
- Note the context information
- break the context
- reconfigure contexts on both source and destination
- resync context on the source
| |||||||||||||||||||||
| !filesystemCorruption | 1.3.6.1.4.1.19746.2.0.7521 | ||||||||||||||||||||
notification · current Description:
Filesystem processing detected some corruption.
This may be isolated to a single file or multiple files,
preventing you from reading the corrupted files.
If a system file is affected, the filesystem could be disabled.
Until this corruption is fixed, you will not be able to run cleaning,
data-movement or space reclamation on the affected tier.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !missingTierStorage | 1.3.6.1.4.1.19746.2.0.7522 | ||||||||||||||||||||
notification · current Description:
Critical storage resources are unavailable, preventing the tier from functioning.
Action:
Verify all storage is functional and configured correctly.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !spaceReclUnitError | 1.3.6.1.4.1.19746.2.0.7523 | ||||||||||||||||||||
notification · current Description:
Space reclamation encountered an error and cannot proceed on the specified archive unit.
If you have more than one archive unit, space reclamation will continue on the next unit.
Space will not be reclaimed in this archive unit until the error condition is resolved
and space reclamation finishes successfully on this unit.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !bMCFailureSysBBU | 1.3.6.1.4.1.19746.2.0.7524 | ||||||||||||||||||||
notification · current Description:
BMC is unresponsive or unable to access some required information. This may be corrected by a BMC reset procedure. If the condition is serious, the file system will be disabled.
Action:
Shut the system down and remove all external power sources from the controller.
Remove the system battery backup unit (BBU).
Wait until all LEDs are off, reinsert the BBU, connect external power, and then power the system up.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !licenseExpiring | 1.3.6.1.4.1.19746.2.0.8001 | ||||||||||||||||||||
notification · current Description:
The temporary license indicated is about to expire. The function provided by this license will cease to operate.
Action:
Contact your [account team] to purchase a license if you wish to continue to use this feature. | |||||||||||||||||||||
| !licenseExpired | 1.3.6.1.4.1.19746.2.0.8002 | ||||||||||||||||||||
notification · current Description:
The temporary license indicated has expired. The function provided by this license has stopped operating.
Action:
Contact your [account team] to purchase a license if you wish to use this feature. | |||||||||||||||||||||
| !unsupportedEnclosurePSU | 1.3.6.1.4.1.19746.2.0.10000 | ||||||||||||||||||||
notification · current Description:
A power supply has been detected in an enclosure which does not provide complete environmental information.
This will not affect normal operations but should be replaced as soon as convenient.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !unsupportedPowerSupply | 1.3.6.1.4.1.19746.2.0.10001 | ||||||||||||||||||||
notification · current Description:
The installed power supply is an unsupported model.
The system may exhibit unexpected behavior.
Action:
Replace the power supply with a supported model.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !openFanDrawer | 1.3.6.1.4.1.19746.2.0.10002 | ||||||||||||||||||||
notification · current Description:
Fan drawer is not closed securely.
Failure to secure the fan drawer may allow the system to overheat and shut down.
Action:
Close and secure the fan drawer.
If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !memoryRiserFault | 1.3.6.1.4.1.19746.2.0.10003 | ||||||||||||||||||||
notification · current Description:
A critical failure has been detected in a memory riser.
Memory attached to this riser may disappear from the system inventory.
The system may exhibit unexpected behavior.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com to replace the memory riser. | |||||||||||||||||||||
| !pCILinkDegraded | 1.3.6.1.4.1.19746.2.0.10004 | ||||||||||||||||||||
notification · current Description:
The system has detected that PCI communication speed is degraded.
This will not cause the system to fail but may impact performance of affected components.
Action:
Reboot the system.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !invalidHardwareCritical | 1.3.6.1.4.1.19746.2.0.10005 | ||||||||||||||||||||
notification · current Description:
During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location.
The filesystem cannot be enabled with the current hardware configuration.
Action:
View enclosure misconfiguration to determine the problem.
For assistance, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !invalidHardwareWarning | 1.3.6.1.4.1.19746.2.0.10006 | ||||||||||||||||||||
notification · current Description:
During device inventory verification, the system found missing or invalid hardware, or devices installed in the wrong location.
Some components may not operate as expected.
Action:
View enclosure misconfiguration to determine the problem.
For assistance, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !correctableErrorWarning | 1.3.6.1.4.1.19746.2.0.10007 | ||||||||||||||||||||
notification · current Description:
The system has detected excessive correctable errors on a component that may indicate a hardware failure.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !spuriousInterruptDisabled | 1.3.6.1.4.1.19746.2.0.10008 | ||||||||||||||||||||
notification · current Description:
Excessive spurious hardware messages have been detected that may indicate a hardware failure.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !corruptEncryptionKeys | 1.3.6.1.4.1.19746.2.0.10009 | ||||||||||||||||||||
notification · current Description: File system was locked as the encryption keys cannot not be validated. One or more encryption keys could be corrupt. Action: Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !duplicateVTLPoolNames | 1.3.6.1.4.1.19746.2.0.10010 | ||||||||||||||||||||
notification · current Description:
VTL directory pool and a VTL mtree pool have been detected with the same name.
Viewing pool information will only retrieve tapes from the mtree pool. Tapes in the
directory pool will not be visible to DataDomain system administration interfaces.
Backups and restores using the directory pool will operate normally.
Action:
Rename one of the pools to make the name unique. The duplicate pool name may have been created as
part of a replication pair.If problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !generalHardwareFailure | 1.3.6.1.4.1.19746.2.0.10011 | ||||||||||||||||||||
notification · current Description:
A critical failure has been detected in one or more chassis components.
The system may exhibit unexpected behavior.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !iOModuleMacFault | 1.3.6.1.4.1.19746.2.0.10013 | ||||||||||||||||||||
notification · current Description:
A Mac fault has been detected with an I/O module and it will not function correctly.
Action:
The I/O module must be replaced.Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !storageMigrationCannotResume | 1.3.6.1.4.1.19746.2.0.10500 | ||||||||||||||||||||
notification · current Description:
The system has detected a condition which prevented the storage
migration from continuing and has suspended the data copy phase.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !storageMigrationCopyComplete | 1.3.6.1.4.1.19746.2.0.10501 | ||||||||||||||||||||
notification · current Description:
All data has been moved from old enclosures to the new enclosures.
Storage migration must be finalized to decommission old enclosures and
add new capacity to the file system.
Action:
Finalize the storage migration. | |||||||||||||||||||||
| !storageMigrationUserSuspend | 1.3.6.1.4.1.19746.2.0.10502 | ||||||||||||||||||||
notification · current Description:
An administrator has suspended the data copy phase of storage migration.
Data copy cannot proceed until it is manually resumed.
Action:
Resume the storage migration. | |||||||||||||||||||||
| !cMTaskEnded | 1.3.6.1.4.1.19746.2.0.10503 | ||||||||||||||||||||
notification · current Description:
A long running task has ended.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !physicalCapacityMeasurementTasksLost | 1.3.6.1.4.1.19746.2.0.10504 | ||||||||||||||||||||
notification · current Description:
File system has been disabled either by a failure or user action.
Physical-capacity-measurement samples for these tasks are no longer available.
Action:
Restart physical-capacity-measurement sample tasks that have not completed. | |||||||||||||||||||||
| !physicalCapacityMeasurementTasksLostMTree | 1.3.6.1.4.1.19746.2.0.10505 | ||||||||||||||||||||
notification · current Description:
MTree replication was broken or resynced causing one or more physical-capacity-measurement sample tasks to be cancelled.
Physical-capacity-measurement samples for these tasks are no longer available.
Action:
Restart physical-capacity-measurement sample tasks that have not completed for this MTree. | |||||||||||||||||||||
| !physicalCapacityMeasurementScheduleFailed | 1.3.6.1.4.1.19746.2.0.10506 | ||||||||||||||||||||
notification · current Description:
A physical-capacity-measurement sample task that was scheduled to run was unable to start due to an error.
Some or all of the physical-capacity-measurement samples for these tasks are not available.
Action:
Review scheduled physical-capacity-measurement sample task errors to determine the reason for the failure.
Resubmit failed tasks if needed. | |||||||||||||||||||||
| !historicalDatabaseFailoverError | 1.3.6.1.4.1.19746.2.0.10507 | ||||||||||||||||||||
notification · current Description:
Historical database failover failed.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com
to help debug the problem. | |||||||||||||||||||||
| !hAdegraded | 1.3.6.1.4.1.19746.2.0.10508 | ||||||||||||||||||||
notification · current Description:
A condition has been detected causing the configured HA system to be degraded.
Any failover attempt will not succeed.
Action:
Display the HA detailed status to determine the failed component.
Repairing the failed component can return the HA system to available state. | |||||||||||||||||||||
| !upgradeInProgress | 1.3.6.1.4.1.19746.2.0.10509 | ||||||||||||||||||||
notification · current Description:
DD OS upgrade is in progress.
The system will not be available for backup and restore operations.
The alert will be cleared after the upgrade operation is complete.
Action:
Allow the upgrade operation to complete. If the upgrade takes longer than usual, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !hAofflineErrors | 1.3.6.1.4.1.19746.2.0.10510 | ||||||||||||||||||||
notification · current Description:
Critical system errors have been detected causing the configured HA system to be in offline state.
Access to system services may be unavailable.
Action:
Review exisiting alerts.
Fixing issues identified by these alerts may resolve this alert.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !suspendedMReplMissingUnits | 1.3.6.1.4.1.19746.2.0.10511 | ||||||||||||||||||||
notification · current Description:
Mtree replication on this context cannot continue until all archive units used by this Mtree are online.
Replication will resume automatically once all archive units come online.
Action:
Return missing archive units to the system to resume MTree replication for this context.
If the archive units cannot be restored, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !foreignPack | 1.3.6.1.4.1.19746.2.0.10512 | ||||||||||||||||||||
notification · current Description:
The enclosure pack is unusable by the file system.
Storage configuration can not be modified while a foreign device is present.
Action:
If this is expected as part of a chassis swap or chassis upgrade, proceed with
the headswap operation to make the foreign filesystem available.
Otherwise contact your contracted support provider or visit us online at https://support.emc.com.
| |||||||||||||||||||||
| !vDiskSCSITargetMismatch | 1.3.6.1.4.1.19746.2.0.10513 | ||||||||||||||||||||
notification · current Description:
VDisk configuration does not match SCSI Target configuration.
Non-matching devices are not available and must be deleted or repaired.
Action:
Contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !hATimeOutOfSync | 1.3.6.1.4.1.19746.2.0.10514 | ||||||||||||||||||||
notification · current Description:
Timestamps of logs and system events will not match between the HA nodes.
This condition will not have an effect on HA functionality or system operation.
Action:
Set the time on the standby node to match the active node.
If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com. | |||||||||||||||||||||
| !enclosureMixDriveType | 1.3.6.1.4.1.19746.2.0.10515 | ||||||||||||||||||||
notification · current Description:
An unsupported mix of enclosures with different drive types may impact performance and lead to unexpected system behavior.
Action:
Recable the enclosures to eliminate the unsupported mix. Refer to the configuration guide for valid cabling configurations. | |||||||||||||||||||||
| !missingSlaveInterface | 1.3.6.1.4.1.19746.2.0.10523 | ||||||||||||||||||||
notification · current Description:
The bonded interface has been created with the remaining interfaces and
may experience degraded performance or reduced failover capability.
Action:
Replace the network interface or reconfigure the bonded interface to
restore functionality. If the problem persists, contact your contracted support provider or visit us online at https://support.emc.com | |||||||||||||||||||||
| !vTLEnabled | 1.3.6.1.4.1.19746.2.0.11105 | ||||||||||||||||||||
notification · current Description:
VTL is enabled. VTL functionality is available to the user.
Action:
Some backup applications may need manual rescanning for devices. | |||||||||||||||||||||
| !vTLDisabled | 1.3.6.1.4.1.19746.2.0.11106 | ||||||||||||||||||||
notification · current Description:
VTL is disabled. VTL functionality is unavailable to the user.
Action:
No Action required. | |||||||||||||||||||||
| NdataDomainMibProducts | 1.3.6.1.4.1.19746.3 | ||||||||||||||||||||
| Nrestorer | 1.3.6.1.4.1.19746.3.1 | ||||||||||||||||||||
| Nunknown | 1.3.6.1.4.1.19746.3.1.0 | ||||||||||||||||||||
| Ndd200 | 1.3.6.1.4.1.19746.3.1.1 | ||||||||||||||||||||
| Ndd200Proto | 1.3.6.1.4.1.19746.3.1.2 | ||||||||||||||||||||
| Ndd410 | 1.3.6.1.4.1.19746.3.1.3 | ||||||||||||||||||||
| Ndd430 | 1.3.6.1.4.1.19746.3.1.4 | ||||||||||||||||||||
| Ndd460 | 1.3.6.1.4.1.19746.3.1.5 | ||||||||||||||||||||
| Ndd400g | 1.3.6.1.4.1.19746.3.1.6 | ||||||||||||||||||||
| Ndd460g | 1.3.6.1.4.1.19746.3.1.7 | ||||||||||||||||||||
| Ndd560 | 1.3.6.1.4.1.19746.3.1.8 | ||||||||||||||||||||
| Ndd560g | 1.3.6.1.4.1.19746.3.1.9 | ||||||||||||||||||||
| Ndd580 | 1.3.6.1.4.1.19746.3.1.10 | ||||||||||||||||||||
| Ndd580g | 1.3.6.1.4.1.19746.3.1.11 | ||||||||||||||||||||
| Ndd565 | 1.3.6.1.4.1.19746.3.1.12 | ||||||||||||||||||||
| Ndd530 | 1.3.6.1.4.1.19746.3.1.13 | ||||||||||||||||||||
| Ndd510 | 1.3.6.1.4.1.19746.3.1.14 | ||||||||||||||||||||
| Ndd120 | 1.3.6.1.4.1.19746.3.1.15 | ||||||||||||||||||||
| Ndd690 | 1.3.6.1.4.1.19746.3.1.16 | ||||||||||||||||||||
| Ndd690g | 1.3.6.1.4.1.19746.3.1.17 | ||||||||||||||||||||
| Ndd660 | 1.3.6.1.4.1.19746.3.1.18 | ||||||||||||||||||||
| Ndd880 | 1.3.6.1.4.1.19746.3.1.19 | ||||||||||||||||||||
| Ndd880g | 1.3.6.1.4.1.19746.3.1.20 | ||||||||||||||||||||
| Ndd610 | 1.3.6.1.4.1.19746.3.1.21 | ||||||||||||||||||||
| Ndd630 | 1.3.6.1.4.1.19746.3.1.22 | ||||||||||||||||||||
| Ndd140 | 1.3.6.1.4.1.19746.3.1.23 | ||||||||||||||||||||
| Ndd670 | 1.3.6.1.4.1.19746.3.1.24 | ||||||||||||||||||||
| Ndd860 | 1.3.6.1.4.1.19746.3.1.25 | ||||||||||||||||||||
| Ndd860g | 1.3.6.1.4.1.19746.3.1.26 | ||||||||||||||||||||
| Ndd890 | 1.3.6.1.4.1.19746.3.1.27 | ||||||||||||||||||||
| Ndd640 | 1.3.6.1.4.1.19746.3.1.28 | ||||||||||||||||||||
| Ndd620 | 1.3.6.1.4.1.19746.3.1.29 | ||||||||||||||||||||
| Ndd160 | 1.3.6.1.4.1.19746.3.1.30 | ||||||||||||||||||||
| Nddintrepid | 1.3.6.1.4.1.19746.3.1.31 | ||||||||||||||||||||
| Ndd4500 | 1.3.6.1.4.1.19746.3.1.32 | ||||||||||||||||||||
| Ndd7200 | 1.3.6.1.4.1.19746.3.1.33 | ||||||||||||||||||||
| Nddve | 1.3.6.1.4.1.19746.3.1.34 | ||||||||||||||||||||
| Ndd990 | 1.3.6.1.4.1.19746.3.1.35 | ||||||||||||||||||||
| Ndd2500 | 1.3.6.1.4.1.19746.3.1.36 | ||||||||||||||||||||
| Ndd4200 | 1.3.6.1.4.1.19746.3.1.37 | ||||||||||||||||||||
| Nddkoalam1 | 1.3.6.1.4.1.19746.3.1.38 | ||||||||||||||||||||
| Napollo | 1.3.6.1.4.1.19746.3.1.39 | ||||||||||||||||||||
| Nunset | 1.3.6.1.4.1.19746.3.1.9999 | ||||||||||||||||||||
Textual conventions
AlertDescriptionTCOCTET STRING (SIZE (0..255))Display hint:
255aAlert Description
AlertIndexTCInteger32 (0..2147483647)Display hint:
dAlert Row Index
AlertTimestampTCOCTET STRING (SIZE (0..64))Display hint:
64aAlert Timestamp
CifsConfigDNSTCOCTET STRING (SIZE (0..1024))Display hint:
1024aCIFS DNS server
CifsConfigDomainControllerTCOCTET STRING (SIZE (0..1024))Display hint:
1024aCIFS Domain Controller
CifsConfigGroupNameTCOCTET STRING (SIZE (0..255))Display hint:
255aCIFS group name
CifsConfigMaxConnectionTCCounter32Display hint:
dCIFS configuration maximum connection
CifsConfigMaxOpenFilesPerConnectionTCCounter32Display hint:
dCIFS configuration maximum open files per connection
CifsConfigModeTCOCTET STRING (SIZE (0..64))Display hint:
64aCurrent CIFS mode
CifsConfigNetBIOSHostnameTCOCTET STRING (SIZE (0..255))Display hint:
255aCIFS NetBIOS hostname
CifsConfigWINSServerTCOCTET STRING (SIZE (0..1024))Display hint:
1024aCIFS WINS servers
CifsOptionsIndexTCInteger32 (0..100)Display hint:
dIndex of CIFS Option Table Index
CifsOptionsNameTCOCTET STRING (SIZE (0..128))Display hint:
128aIndex of CIFS Option Name
CifsOptionsValueTCOCTET STRING (SIZE (0..128))Display hint:
128aIndex of CIFS Option Value
disabled(2)enabled(1)Current CIFS browsing
Display hint:
1024aCIFS share clients
Display hint:
255aCIFS share comment
Display hint:
dIndex of CIFS share
Display hint:
dCIFS maximum connection
Display hint:
255aCIFS share name
Display hint:
1024aCIFS share path
Display hint:
1024aCIFS share user
disabled(2)enabled(1)Current CIFS writeable
CifsStatsDetailsIndexTCInteger32 (0..2147483647)Display hint:
dIndex of CIFS Stats Details Table
CifsStatsSummaryIndexTCInteger32 (0..2147483647)Display hint:
dIndex of Cifs Stats Summary Table
CifsStatusTCINTEGERdisabled(5)enabled(1)enabledNotRunning(3)enabledRunning(2)enabledWindbindNotRun(4)Current CIFS status
DDMibAlertSeverityTCOCTET STRING (SIZE (0..64))Display hint:
64aData Domain Alert Severity
DDMibCompressionFactorTCOCTET STRING (SIZE (0..20))Display hint:
20aData Domain compression factor
DDMibDateTCOCTET STRING (SIZE (0..16))Display hint:
16aData Domain Mib Date in the yyyy-mm-dd hh:mm format
DDMibInteger32TCInteger32Display hint:
dData Domain Mib Integer 32.
DDMibMemorySizeTCInteger32Display hint:
dData Domain Mib Memory Size of in bytes.
DDMibStatusTCINTEGERdisabled(2)enabled(1)DD Mib Status
DDMibString96TCOCTET STRING (SIZE (0..96))Display hint:
96aDD Mib String 96
DDMibTableEnabledTCINTEGERno(0)yes(1)DD Mib Table Enabled
DDMibTableIndexTCInteger32 (0..2147483647)Display hint:
dIndex for Any Data Domain MIB table
DDMibTableSizeGibTCOCTET STRING (SIZE (0..20))Display hint:
20aData Domain Compression size in GiB
DDMibTableSizeMiBTCOCTET STRING (SIZE (0..32))Display hint:
32aData Domain size in MiB
DDMibTableString1024TCOCTET STRING (SIZE (0..1024))Display hint:
1024aDD Mib Table String 1024
DDMibTableString128TCOCTET STRING (SIZE (0..128))Display hint:
128aDD Mib Table String 128
DDMibTableString256TCOCTET STRING (SIZE (0..256))Display hint:
256aDD Mib Table String 256
DDMibTableString32TCOCTET STRING (SIZE (0..32))Display hint:
32aDD Mib Table String 32
DDMibTableString512TCOCTET STRING (SIZE (0..512))Display hint:
512aDD Mib Table String 512
DDMibTableString64TCOCTET STRING (SIZE (0..64))Display hint:
64aDD Mib Table String 64
DDMibTimeStampTCOCTET STRING (SIZE (0..64))Display hint:
64aDD Mib Timestamp
DDMibTrafficBytesTCCounter64Display hint:
dmeasurement of bytes being transferred
DDMibVersionTCOCTET STRING (SIZE (0..64))Display hint:
64aData Domain Mib version
DDStatusTCINTEGERdisabled(0)enabled(1)DD feature Status
DDboostStatsIndexTCInteger32 (0..2147483647)Display hint:
dIndex of ddboost Stats Table
DDboostStatusTCINTEGERdisabled(2)enabled(1)DDboost Status
DDboostUserTCOCTET STRING (SIZE (0..1024))Display hint:
1024aDDboost user
DateTCOCTET STRING (SIZE (0..16))Display hint:
16aDate in the yyyy-mm-dd hh:mm format
DdboostAccessClientsAuthModeTCINTEGERanonymous(3)none(0)oneWay(1)twoWay(2)The types of Ddboost access clients authentication mode
DdboostAccessClientsEncryStrengthTCINTEGERhigh(3)medium(2)none(0)The types of Ddboost access clients encryption strength level
DiskCapacityTCOCTET STRING (SIZE (0..20))Display hint:
20aCapacity of disk
DiskFirmwareVersionTCOCTET STRING (SIZE (0..64))Display hint:
64aFirmware version of disk
DiskIndexTCInteger32 (0..2147483647)Display hint:
dDisk Number of disk that is present in the DDR
DiskModelTCOCTET STRING (SIZE (0..64))Display hint:
64aManufacture & Model Number of disk
DiskPackTCINTEGERnotapplicable(0)pack1(1)pack2(2)pack3(3)pack4(4)Pack number for disks of ES60.
DiskSectorsPerSecondTCCounter32Display hint:
dNumber of disk sectors being transferred per second
DiskSerialNumberTCOCTET STRING (SIZE (0..64))Display hint:
64aSerial Number of disk
DiskStateTCINTEGERabsent(3)available(6)failed(4)ok(1)spare(5)unknown(2)Current Disk State
EnclosureIDInteger32 (1..2147483647)Display hint:
dunique Enclosure ID, used as index in several tables
ErrorCountCounter32Display hint:
dNumber of Errors Encountered
FanDescriptionTCOCTET STRING (SIZE (0..64))Display hint:
64aFan Description
FanIndexTCInteger32 (0..2147483647)Display hint:
dFan Number of fan that is present in DDR
FanLevelTCINTEGERhigh(3)low(1)medium(2)unknown(0)Current Fan level
FanStatusTCINTEGERfail(2)notfound(0)ok(1)Current Fan Status
FileSystemArchiveUnitStateTCINTEGERnew(1)sealed(3)target(2)File System Archive Unit State
FileSystemArchiveUnitStatusTCINTEGERdisabled(2)ready(1)File System Archive Unit Status
FileSystemCleanIndexTCInteger32 (0..2147483647)Display hint:
dFile System Clean Index
FileSystemCleanScheduleTCOCTET STRING (SIZE (0..128))Display hint:
128aFile System Clean Schedule
FileSystemCleanStatusTCOCTET STRING (SIZE (0..128))Display hint:
128aFile System Clean Status
FileSystemCleanThrottleTCOCTET STRING (SIZE (0..128))Display hint:
128aFile System Clean throttle
FileSystemCompressionFactorTCOCTET STRING (SIZE (0..20))Display hint:
20aFile System compression factor
FileSystemCompressionPeriodTCOCTET STRING (SIZE (0..20))Display hint:
20aFile System compression period: last 24 hours, last 7 days
FileSystemCompressionSizeTCOCTET STRING (SIZE (0..20))Display hint:
20aFile Systems Compression size in GiB
FileSystemOptionsIndexTCInteger32 (0..2147483647)Display hint:
dIndex of File System Option Table Index
FileSystemOptionsNameTCOCTET STRING (SIZE (0..128))Display hint:
128aIndex of File Systems Option Name
FileSystemOptionsValueTCOCTET STRING (SIZE (0..128))Display hint:
128aIndex of File Systems Option Value
FileSystemResourceIndexTCInteger32 (0..2147483647)Display hint:
dResource Number of file system resource
FileSystemResourceNameTCOCTET STRING (SIZE (0..64))Display hint:
64aFile System resource name
FileSystemSpaceUnitTCOCTET STRING (SIZE (0..20))Display hint:
20aUnits of space in the file System represented in Gigabytes
FileSystemStatusTCINTEGERcleaning(6)disabled(2)enabled(1)error(5)running(3)unknown(4)Current File System Status
HaStatusTCINTEGERnotApplicable(3)notOk(2)ok(1)unknown(0)The status of a high availabiilty component.
HaSystemStatusTCINTEGERdegraded(2)highlyAvailable(1)unknown(0)The status of the high availabiilty system.
KBytesPerSecondCounter32Display hint:
dNumber of KBytes transferred per second
MinutesInteger32Display hint:
dMinutes
MtreeListStatusTCINTEGERdeleted(1)readOnly(2)readWrite(3)replicationDestination(4)retentionLockDisabled(6)retentionLockEnabled(5)Mtree List Status TC
MtreeRetentionLockStatusTCINTEGERdisabled(2)enabled(1)Mtree Retention Lock
NfsClientClientsTCOCTET STRING (SIZE (0..1024))Display hint:
1024aNFS Clients
NfsClientIndexTCInteger32 (0..2147483647)Display hint:
dIndex of NFS clients
NfsClientOptionsTCOCTET STRING (SIZE (0..254))Display hint:
254aNFS options
NfsClientPathTCOCTET STRING (SIZE (0..1024))Display hint:
1024aNFS path
NfsStatsCacheEntryTCCounter32Display hint:
dNumber of cache entries
NfsStatsCurrentOpenStreamsTCCounter32Display hint:
dNumber of current open streams
NfsStatsExportPointTCOCTET STRING (SIZE (0..254))Display hint:
254aNFS export point
NfsStatsFileHandleLookupTCCounter32Display hint:
dNumber of file handle lookup
NfsStatsFilesystemTypeTCOCTET STRING (SIZE (0..32))Display hint:
32aNFS file system type
NfsStatsIndexTCInteger32 (0..2147483647)Display hint:
dIndex of NFS stats
NfsStatsMaxCacheSizeTCCounter32Display hint:
dMax cache size
NfsStatusTCINTEGERdisabled(2)enabled(1)Current Network File System Status
NvramBatteryIndexTCInteger32 (0..2147483647)Display hint:
dNumber of NVRAM Battery present in the DDR
NvramBatteryStatusTCINTEGERdisabled(1)discharged(2)ok(0)softdisabled(3)Current NVRAM Battery Status Status Description -------------------------------- ok charged and enabled discharged charging and enabled
NvramHCPropertyBytesTCCounter64Display hint:
dValue of an NVRAM high capacity property in bytes.
NvramIndexTCInteger32 (0..2147483647)Display hint:
dIndex of NVRAM card present in the DDR
NvramMemorySizeTCInteger32Display hint:
dMemory Size of NVRAM in bytes.
NvramWindowSizeTCInteger32Display hint:
dWindow Size of NVRAM in bytes.
OpsPerSecondCounter32Display hint:
dNumber of Operations performed per second
PercentageInteger32 (0..100)Display hint:
dPercentage
PercentageStrOCTET STRING (SIZE (0..20))Display hint:
20aPercentage string
PowerModuleDescriptionTCOCTET STRING (SIZE (0..64))Display hint:
64aPower Module Description
PowerModuleIndexTCInteger32 (0..2147483647)Display hint:
dNumber of Power Module present in the DDR
PowerModuleStatusTCINTEGERabsent(0)acnone(4)failed(2)faulty(3)ok(1)unknown(99)Current Power Module Status
RaidDiskStateTCINTEGERabsent(4)available(9)failed(5)foreign(7)inuse(1)invalid(6)known(8)notinuse(2)spare(3)unknown(99)Raid Disk State
ReplicationConfigConnHostTCOCTET STRING (SIZE (0..256))Display hint:
256aReplicaton Configuration Connection Host
ReplicationConfigConnPortTCOCTET STRING (SIZE (0..256))Display hint:
256aReplicaton Configuration Connection Port
ReplicationConfigContextIdTCOCTET STRING (SIZE (0..32))Display hint:
32aReplicaton Configuration Context Id
ReplicationConfigDestTCOCTET STRING (SIZE (0..256))Display hint:
256aReplicaton Configuration Destination
ReplicationConfigEnabledTCINTEGERno(0)yes(1)Replication Configuration Enabled
ReplicationConfigIndexTCInteger32 (0..2147483647)Display hint:
dReplication Config Row Index
ReplicationConfigLowBWOptimTCINTEGERdisabled(0)enabled(1)Replication Low BW Optimization Status
ReplicationConfigSourceTCOCTET STRING (SIZE (0..256))Display hint:
256aReplicaton Configuration Connection Source
ReplicationConnectTimeTCInteger32Display hint:
dtimestamp when connection was established, or 0 if there is no Replication connection
ReplicationContextTCInteger32 (0..2147483647)Display hint:
d0 for collection replication contexts, > 0 for directory replication contexts
ReplicationPathTCOCTET STRING (SIZE (0..254))Display hint:
254asource or destination path for replication
ReplicationStateTCINTEGERinitializing(1)normal(2)recovering(3)uninitialized(4)Current Replication status
ReplicationStatusTCINTEGERconnected(1)disconnected(2)idle(6)migrating(3)neverConnected(5)suspended(4)Current Replication connection status
ReplicationSyncedTimeTCInteger32Display hint:
dtimestamp when replication source and destination were in sync, or 0 if unknown
ReplicationThrottleTCInteger32Display hint:
dmeasurement of replication throttle in bps
ReplicationTrafficTCCounter64Display hint:
dmeasurement of bytes being replicated
SmtStatusTCINTEGERdisabled(0)enabled(1)Status of the SMT feature components. They may be enabled or disabled.
SystemNotesTCOCTET STRING (SIZE (0..1024))Display hint:
1024aSystem notes
SystemSerialNumberTCOCTET STRING (SIZE (0..128))Display hint:
128aSystem Serial Number
SystemStatsIndexTCInteger32 (0..2147483647)Display hint:
dStatistics Row Index
SystemTimeZoneNameTCOCTET STRING (SIZE (0..64))Display hint:
64aDDR system's time zone name
TempSensorDescriptionTCOCTET STRING (SIZE (0..64))Display hint:
64aTemperature Sensor Description
TempSensorIndexTCInteger32 (0..2147483647)Display hint:
dNumber of Temperature Sensor present in the DDR
TempSensorStatusTCINTEGERfailed(0)notfound(2)ok(1)overheatCritical(4)overheatWarning(3)Current Temperature Sensor Status
TemperatureInteger32Display hint:
dTemperature value in Celsius
TenantUnitMgmtGroupTypeTCINTEGERad(3)all(0)ldap(5)local(2)nis(4)unknown(1)The type of a Management group of a tenant-unit.
TenantUnitMgmtUserListUserRoleTCINTEGERtenantAdmin(1)tenantUser(2)The role of a Management user of a tenant-unit. It can be tenant-admin (1) or tenant-user (2).
TenantUnitSecurityModeTCINTEGERdefault(2)strict(1)The security mode of a tenant-unit. It can be strict (1) or default (2).
VtlAdminStateTCINTEGERdisabled(2)enabled(1)failed(3)unknown(0)Current VTL administration state
VtlDriveIndexTCInteger32 (0..512)Display hint:
dIndex of VTL drive
VtlDriveModelTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL drive model
VtlDriveNameTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL drive name
VtlDriveRevisionTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL drive revision
VtlDriveSerialTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL drive serial
VtlDriveStatusTCINTEGERoffline(2)online(1)unknown(0)Current VTL drive status
VtlDriveTapeVolumeTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL drive tape volume
VtlDriveVendorTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL drive vendor
VtlLibraryIndexTCInteger32 (0..64)Display hint:
dIndex of VTL library
VtlLibraryModelTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL library model
VtlLibraryNameTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL library name
VtlLibraryRevisionTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL library revision
VtlLibrarySerialTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL library serial
VtlLibraryStatusTCINTEGERoffline(2)online(1)unknown(0)Current VTL library status
VtlLibraryTotalCapsTCCounter32Display hint:
dNumber of VTL caps
VtlLibraryTotalDrivesTCCounter32Display hint:
dNumber of VTL drives
VtlLibraryTotalSlotsTCCounter32Display hint:
dNumber of VTL slots
VtlLibraryVendorTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL library vendor
VtlPortConnectionTypeTCINTEGERfabricLoop(3)loop(1)nPORT(0)pointToPoint(2)unknown(4)VTL Port Connection Type
VtlPortEnabledTCINTEGERdisabled(0)enabled(1)unknown(2)VTL Port Enabled
VtlPortFirmwareTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Port Firmware
VtlPortIDTCCounter32Display hint:
dVTL Port Id
VtlPortIndexTCInteger32 (0..10)Display hint:
dVTL Port Table Index
VtlPortModelTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Port MODEL
VtlPortNameTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Port Name
VtlPortSpeedTCINTEGEReightGBPS(4)fourGBPS(3)oneGBPS(1)twoGBPS(2)unknown(6)zeroGBPS(0)VTL Port Speed
VtlPortStatusTCINTEGERoffline(0)online(1)unknown(2)VTL Port State
VtlPortWWNNTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL WWNN Address
VtlPortWWPNTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL WWPN Address
VtlProcessStateTCINTEGERrunning(3)starting(2)stopped(1)stopping(5)stuck(6)timingout(4)unknown(0)Current VTL process state
VtlStatsConrolCommandsTCCounter64Display hint:
dVTL Stats Table Control Commands
VtlStatsInTCCounter64Display hint:
dVTL Stats Table Stats In
VtlStatsIndexTCInteger32 (0..2147483647)Display hint:
dVTL Stats Table Index
VtlStatsInvalidCRCsTCCounter64Display hint:
dVTL Stats Table Invalid CRCs
VtlStatsInvalidTxWordsTCCounter64Display hint:
dVTL Stats Table Invalid Tx Words
VtlStatsLIPCountTCCounter64Display hint:
dVTL Stats Table LIP count
VtlStatsLinkFailuresTCCounter64Display hint:
dVTL Stats Table Link failures
VtlStatsOutTCCounter64Display hint:
dVTL Stats Table Stats Out
VtlStatsPortTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape Bar Code
VtlStatsPrimSeqProtoErrorsTCCounter64Display hint:
dVTL Stats Table Prim Seq Protocol Errors
VtlStatsReadCommandsTCCounter64Display hint:
dVTL Stats Table Read Commands
VtlStatsSignalLossesTCCounter64Display hint:
dVTL Stats Table Signal Losses
VtlStatsSyncLossesTCCounter64Display hint:
dVTL Stats Table Sync Losses
VtlStatsWriteCommandsTCCounter64Display hint:
dVTL Stats Table write commands
VtlTapeBarCodeTCOCTET STRING (SIZE (0..64))Display hint:
64aVTL Tape Bar Code
VtlTapeCompTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape Compression
VtlTapeIndexTCInteger32 (0..250000)Display hint:
dVTL Tape Table Index
VtlTapeLocationTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape Location
VtlTapeModTimeTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape Mod Time
VtlTapePoolTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape Pool
VtlTapeSizeTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape Size
VtlTapeStateTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape State
VtlTapeUsedTCOCTET STRING (SIZE (0..32))Display hint:
32aVTL Tape Used
Traps / Notifications
- abnormalShutdown
1.3.6.1.4.1.19746.2.0.5026 - bMCFailure
1.3.6.1.4.1.19746.2.0.7000 - bMCFailureSysBBU
1.3.6.1.4.1.19746.2.0.7524 - bMCHangCritical
1.3.6.1.4.1.19746.2.0.5025 - bMCHangShutdown
1.3.6.1.4.1.19746.2.0.6537 - bMCPartialHang
1.3.6.1.4.1.19746.2.0.6015 - cMTaskEnded
1.3.6.1.4.1.19746.2.0.10503 - cPUFailureWarning
1.3.6.1.4.1.19746.2.0.5023 - chassisFailure
1.3.6.1.4.1.19746.2.0.6527 - chassisSensorCritical
1.3.6.1.4.1.19746.2.0.5020 - chassisTempCritical
1.3.6.1.4.1.19746.2.0.5022 - chassisTempWarning
1.3.6.1.4.1.19746.2.0.5021 - cleaningError
1.3.6.1.4.1.19746.2.0.6014 - clusterInterfaceAlarm
1.3.6.1.4.1.19746.2.0.29 - clusterNodeAlarm
1.3.6.1.4.1.19746.2.0.28 - compromisedEncryptionKeys
1.3.6.1.4.1.19746.2.0.6001 - containerMarkedInvalid
1.3.6.1.4.1.19746.2.0.5501 - controllerIfaceUnreachableAlert
1.3.6.1.4.1.19746.2.0.5003 - controllerUnreachableAlert
1.3.6.1.4.1.19746.2.0.5002 - coredumpDisabled
1.3.6.1.4.1.19746.2.0.5079 - coredumpWarning
1.3.6.1.4.1.19746.2.0.5078 - correctECCWarning
1.3.6.1.4.1.19746.2.0.5014 - correctableECCLimitReached
1.3.6.1.4.1.19746.2.0.5004 - correctableErrorWarning
1.3.6.1.4.1.19746.2.0.10007 - corruptEncryptionKeys
1.3.6.1.4.1.19746.2.0.10009 - cpismissing
1.3.6.1.4.1.19746.2.0.5500 - dDFSDied
1.3.6.1.4.1.19746.2.0.5037 - dDFSDiedAfterReboot
1.3.6.1.4.1.19746.2.0.5036 - dDFSFailedInShutdown
1.3.6.1.4.1.19746.2.0.5030 - dDFSNoHeartbeat
1.3.6.1.4.1.19746.2.0.5034 - dDFSRebooted
1.3.6.1.4.1.19746.2.0.5038 - dDFSRebootedDisabled
1.3.6.1.4.1.19746.2.0.5039 - dDFSRequiresReboot
1.3.6.1.4.1.19746.2.0.7516 - dIMMFailure
1.3.6.1.4.1.19746.2.0.6525 - dIMMFailureAlert
1.3.6.1.4.1.19746.2.0.5048 - dNSUnresponsive
1.3.6.1.4.1.19746.2.0.7504 - diskAccessError
1.3.6.1.4.1.19746.2.0.5082 - diskFailedAlarm
1.3.6.1.4.1.19746.2.0.14 - diskFailure
1.3.6.1.4.1.19746.2.0.5083 - diskGroupReconstruction
1.3.6.1.4.1.19746.2.0.5089 - diskGroupReconstructionCritical
1.3.6.1.4.1.19746.2.0.5091 - diskGroupReconstructionNoProgress
1.3.6.1.4.1.19746.2.0.5088 - diskGroupReconstructionShutdown
1.3.6.1.4.1.19746.2.0.5090 - diskNoSpareAlarm
1.3.6.1.4.1.19746.2.0.22 - diskOverheatAlertAlarm
1.3.6.1.4.1.19746.2.0.16 - diskOverheatShutdownAlarm
1.3.6.1.4.1.19746.2.0.17 - diskOverheatWarningAlarm
1.3.6.1.4.1.19746.2.0.15 - diskPathAlarm
1.3.6.1.4.1.19746.2.0.23 - diskPathRedundancy
1.3.6.1.4.1.19746.2.0.5051 - diskPathSpeedDegraded
1.3.6.1.4.1.19746.2.0.7507 - diskSASAlarm
1.3.6.1.4.1.19746.2.0.24 - diskSASHBAAlarm
1.3.6.1.4.1.19746.2.0.25 - diskTemperatureShutdown
1.3.6.1.4.1.19746.2.0.5085 - diskTemperatureWarning
1.3.6.1.4.1.19746.2.0.5084 - diskUnknown
1.3.6.1.4.1.19746.2.0.5092 - diskUnsupportedAlarm
1.3.6.1.4.1.19746.2.0.35 - driveMixType
1.3.6.1.4.1.19746.2.0.7002 - duplicateAddressDetection
1.3.6.1.4.1.19746.2.0.6530 - duplicateVTLPoolNames
1.3.6.1.4.1.19746.2.0.10010 - enclosureHighTemp
1.3.6.1.4.1.19746.2.0.6535 - enclosureMixDriveType
1.3.6.1.4.1.19746.2.0.10515 - enclosureMixType
1.3.6.1.4.1.19746.2.0.5528 - encryptionKeyExportFailed
1.3.6.1.4.1.19746.2.0.6540 - encryptionKeyTableFull
1.3.6.1.4.1.19746.2.0.6003 - eventIPMIUnmanageAlarm
1.3.6.1.4.1.19746.2.0.36 - expiredHostCertificate
1.3.6.1.4.1.19746.2.0.6538 - ext3NvlogDisabled
1.3.6.1.4.1.19746.2.0.5527 - fanFault
1.3.6.1.4.1.19746.2.0.6517 - fanModuleFailedAlarm
1.3.6.1.4.1.19746.2.0.5 - fanWarning
1.3.6.1.4.1.19746.2.0.5011 - fileMigrationError
1.3.6.1.4.1.19746.2.0.6016 - fileSpaceCriticalAlarm
1.3.6.1.4.1.19746.2.0.12 - fileSpaceMaintenanceAlarm
1.3.6.1.4.1.19746.2.0.8 - fileSpacePreWarningAlarm
1.3.6.1.4.1.19746.2.0.9 - fileSpaceSevereAlarm
1.3.6.1.4.1.19746.2.0.11 - fileSpaceWarningAlarm
1.3.6.1.4.1.19746.2.0.10 - fileSystemFailedAlarm
1.3.6.1.4.1.19746.2.0.7 - filesysDDGCFailedAlarm
1.3.6.1.4.1.19746.2.0.33 - filesysGeneralProblemAlarm
1.3.6.1.4.1.19746.2.0.34 - filesysRelaunchAlarm
1.3.6.1.4.1.19746.2.0.32 - filesystemCorruption
1.3.6.1.4.1.19746.2.0.7521 - filesystemNVRAMDataLoss
1.3.6.1.4.1.19746.2.0.6005 - filesystemProblem
1.3.6.1.4.1.19746.2.0.5028 - forcedControllerShutdown
1.3.6.1.4.1.19746.2.0.6528 - foreignEnclosure
1.3.6.1.4.1.19746.2.0.6019 - foreignPack
1.3.6.1.4.1.19746.2.0.10512 - generalHardwareFailure
1.3.6.1.4.1.19746.2.0.10011 - hATimeOutOfSync
1.3.6.1.4.1.19746.2.0.10514 - hAdegraded
1.3.6.1.4.1.19746.2.0.10508 - hAofflineErrors
1.3.6.1.4.1.19746.2.0.10510 - hDTFileTransferFailed
1.3.6.1.4.1.19746.2.0.5046 - hDTSystemError
1.3.6.1.4.1.19746.2.0.5047 - historicalDatabaseBackupError
1.3.6.1.4.1.19746.2.0.5042 - historicalDatabaseFailoverError
1.3.6.1.4.1.19746.2.0.10507 - historicalDatabasePruneError
1.3.6.1.4.1.19746.2.0.5044 - historicalDatabaseRecoverError
1.3.6.1.4.1.19746.2.0.5041 - historicalDatabaseUpgradeError
1.3.6.1.4.1.19746.2.0.5043 - iOModuleFault
1.3.6.1.4.1.19746.2.0.6522 - iOModuleInserted
1.3.6.1.4.1.19746.2.0.6523 - iOModuleMacFault
1.3.6.1.4.1.19746.2.0.10013 - indexRebuildComplete
1.3.6.1.4.1.19746.2.0.5040 - insecureEncryptedReplication
1.3.6.1.4.1.19746.2.0.6102 - insufficientSpaceForEncryption
1.3.6.1.4.1.19746.2.0.7515 - interfaceConnectivityDown
1.3.6.1.4.1.19746.2.0.6009 - interfaceConnectivityIntermittent
1.3.6.1.4.1.19746.2.0.6010 - interfaceConnectivityUpAndRunning
1.3.6.1.4.1.19746.2.0.6020 - interfaceMisconfiguration
1.3.6.1.4.1.19746.2.0.6011 - invalidEnclosureTopology
1.3.6.1.4.1.19746.2.0.7506 - invalidHardwareCritical
1.3.6.1.4.1.19746.2.0.10005 - invalidHardwareWarning
1.3.6.1.4.1.19746.2.0.10006 - invalidNICSlot
1.3.6.1.4.1.19746.2.0.6512 - legacyBMCHangCritical
1.3.6.1.4.1.19746.2.0.5024 - legacyChassisTempCritical
1.3.6.1.4.1.19746.2.0.5007 - legacyChassisTempWarning
1.3.6.1.4.1.19746.2.0.5006 - legacyFanWarning
1.3.6.1.4.1.19746.2.0.5009 - legacyPowerSupplyWarning
1.3.6.1.4.1.19746.2.0.5008 - licenseExpired
1.3.6.1.4.1.19746.2.0.8002 - licenseExpiring
1.3.6.1.4.1.19746.2.0.8001 - lowSpares
1.3.6.1.4.1.19746.2.0.5094 - mailserverError
1.3.6.1.4.1.19746.2.0.6511 - memoryAlert
1.3.6.1.4.1.19746.2.0.5049 - memoryRiserFault
1.3.6.1.4.1.19746.2.0.10003 - metadataWarningThreshold
1.3.6.1.4.1.19746.2.0.7519 - mgmtModuleFault
1.3.6.1.4.1.19746.2.0.6524 - missingCreplUnits
1.3.6.1.4.1.19746.2.0.6544 - missingDiskGroup
1.3.6.1.4.1.19746.2.0.5087 - missingDiskPath
1.3.6.1.4.1.19746.2.0.5054 - missingEnclosurePath
1.3.6.1.4.1.19746.2.0.5055 - missingHostCertificate
1.3.6.1.4.1.19746.2.0.6018 - missingLunPath
1.3.6.1.4.1.19746.2.0.5053 - missingPortConnection
1.3.6.1.4.1.19746.2.0.5052 - missingSlaveInterface
1.3.6.1.4.1.19746.2.0.10523 - missingTierStorage
1.3.6.1.4.1.19746.2.0.7522 - mtreeCascadeNeedResync
1.3.6.1.4.1.19746.2.0.7520 - mtreeQuotaHardLimit
1.3.6.1.4.1.19746.2.0.6008 - mtreeQuotaSoftLimit
1.3.6.1.4.1.19746.2.0.6007 - multipleDiskReadErrors
1.3.6.1.4.1.19746.2.0.6543 - nISCommFailure
1.3.6.1.4.1.19746.2.0.7501 - nTPDFailed
1.3.6.1.4.1.19746.2.0.7505 - newEncryptionKey
1.3.6.1.4.1.19746.2.0.6002 - noHistoricalDatabaseError
1.3.6.1.4.1.19746.2.0.5045 - nvramBattAlert
1.3.6.1.4.1.19746.2.0.6507 - nvramBattEndOfLife
1.3.6.1.4.1.19746.2.0.6545 - nvramBatteryAlert
1.3.6.1.4.1.19746.2.0.5060 - nvramBatteryLowChargeAlert
1.3.6.1.4.1.19746.2.0.5508 - nvramCondAlert
1.3.6.1.4.1.19746.2.0.6508 - nvramEnvAlert
1.3.6.1.4.1.19746.2.0.6505 - nvramErrorAlert
1.3.6.1.4.1.19746.2.0.5061 - nvramEventHWAlert
1.3.6.1.4.1.19746.2.0.6506 - nvramFailingAlarm
1.3.6.1.4.1.19746.2.0.6 - nvramHWAlert
1.3.6.1.4.1.19746.2.0.6504 - nvramWarning
1.3.6.1.4.1.19746.2.0.5059 - openFanDrawer
1.3.6.1.4.1.19746.2.0.10002 - pCILinkDegraded
1.3.6.1.4.1.19746.2.0.10004 - phyalert
1.3.6.1.4.1.19746.2.0.5062 - physicalCapacityMeasurementScheduleFailed
1.3.6.1.4.1.19746.2.0.10506 - physicalCapacityMeasurementTasksLost
1.3.6.1.4.1.19746.2.0.10504 - physicalCapacityMeasurementTasksLostMTree
1.3.6.1.4.1.19746.2.0.10505 - portPathDisabled
1.3.6.1.4.1.19746.2.0.5050 - powerSupplyAbsent
1.3.6.1.4.1.19746.2.0.6520 - powerSupplyFailedAlarm
1.3.6.1.4.1.19746.2.0.1 - powerSupplyFailure
1.3.6.1.4.1.19746.2.0.6519 - powerSupplyInputFault
1.3.6.1.4.1.19746.2.0.6518 - powerSupplyWarning
1.3.6.1.4.1.19746.2.0.5010 - powerUnitWarning
1.3.6.1.4.1.19746.2.0.5017 - powerWarning
1.3.6.1.4.1.19746.2.0.5013 - processorWarning
1.3.6.1.4.1.19746.2.0.5016 - raidGroupMissingAlarm
1.3.6.1.4.1.19746.2.0.21 - raidReconCriticalAlarm
1.3.6.1.4.1.19746.2.0.19 - raidReconCriticalShutdownAlarm
1.3.6.1.4.1.19746.2.0.20 - raidReconSevereAlarm
1.3.6.1.4.1.19746.2.0.18 - recoverFromNVRAMFailed
1.3.6.1.4.1.19746.2.0.6013 - replDestNotConfigured
1.3.6.1.4.1.19746.2.0.5067 - replIncompatibleWorm
1.3.6.1.4.1.19746.2.0.5066 - replLagThreshholdReached
1.3.6.1.4.1.19746.2.0.5068 - replLogFull
1.3.6.1.4.1.19746.2.0.5065 - replNeedResync
1.3.6.1.4.1.19746.2.0.5064 - replPathTooLong
1.3.6.1.4.1.19746.2.0.5531 - replProgressThreshholdReached
1.3.6.1.4.1.19746.2.0.5063 - replSyncAlarm
1.3.6.1.4.1.19746.2.0.30 - sASEnclosureCheck
1.3.6.1.4.1.19746.2.0.5069 - sASHBAErrors
1.3.6.1.4.1.19746.2.0.6515 - sASHBAFailure
1.3.6.1.4.1.19746.2.0.6514 - sASPortDisabled
1.3.6.1.4.1.19746.2.0.5071 - sASTopologyCheck
1.3.6.1.4.1.19746.2.0.5070 - sCSITGTInvalidRegistry
1.3.6.1.4.1.19746.2.0.6539 - sMSUnresponsive
1.3.6.1.4.1.19746.2.0.7500 - sNTZMultipleIterations
1.3.6.1.4.1.19746.2.0.5077 - sPFault
1.3.6.1.4.1.19746.2.0.6526 - sSDEndOfLife
1.3.6.1.4.1.19746.2.0.6541 - sSLCertificateCorrupted
1.3.6.1.4.1.19746.2.0.5072 - smiMrc
1.3.6.1.4.1.19746.2.0.5502 - snapshotFullAlarm
1.3.6.1.4.1.19746.2.0.26 - snapshotHWMAlarm
1.3.6.1.4.1.19746.2.0.27 - snapshotLimitReached
1.3.6.1.4.1.19746.2.0.5076 - snapshotOver90Percent
1.3.6.1.4.1.19746.2.0.5075 - spaceOver80Percent
1.3.6.1.4.1.19746.2.0.5080 - spaceOver90Percent
1.3.6.1.4.1.19746.2.0.5081 - spaceReclError
1.3.6.1.4.1.19746.2.0.6534 - spaceReclMissingUnit
1.3.6.1.4.1.19746.2.0.6532 - spaceReclRestartFailed
1.3.6.1.4.1.19746.2.0.6531 - spaceReclSuspended
1.3.6.1.4.1.19746.2.0.7518 - spaceReclUnitError
1.3.6.1.4.1.19746.2.0.7523 - spaceReclUnitReclaimed
1.3.6.1.4.1.19746.2.0.6533 - spuriousInterruptDisabled
1.3.6.1.4.1.19746.2.0.10008 - storageMigrationCannotResume
1.3.6.1.4.1.19746.2.0.10500 - storageMigrationCopyComplete
1.3.6.1.4.1.19746.2.0.10501 - storageMigrationUserSuspend
1.3.6.1.4.1.19746.2.0.10502 - storageUnitStreamSoftLimit
1.3.6.1.4.1.19746.2.0.7517 - suspendedMReplMissingUnits
1.3.6.1.4.1.19746.2.0.10511 - systemOverheatAlertAlarm
1.3.6.1.4.1.19746.2.0.3 - systemOverheatShutdownAlarm
1.3.6.1.4.1.19746.2.0.4 - systemOverheatWarningAlarm
1.3.6.1.4.1.19746.2.0.2 - systemReset
1.3.6.1.4.1.19746.2.0.6529 - systemStartupAlarm
1.3.6.1.4.1.19746.2.0.31 - tapeReposition
1.3.6.1.4.1.19746.2.0.6542 - targetDriverPortCore
1.3.6.1.4.1.19746.2.0.7510 - targetDriverPortFWLoadFailed
1.3.6.1.4.1.19746.2.0.7512 - targetDriverPortMultipleCore
1.3.6.1.4.1.19746.2.0.7511 - targetDriverPortOffline
1.3.6.1.4.1.19746.2.0.7508 - targetDriverPortOnline
1.3.6.1.4.1.19746.2.0.7509 - targetDriverPortTooManyOsc
1.3.6.1.4.1.19746.2.0.7514 - targetDriverPortUnreadable
1.3.6.1.4.1.19746.2.0.7513 - tcpZeroWindowAlert
1.3.6.1.4.1.19746.2.0.6101 - tooManyRelaunches
1.3.6.1.4.1.19746.2.0.5027 - unCorrectECCWarning
1.3.6.1.4.1.19746.2.0.5018 - uncertifiedFirmware
1.3.6.1.4.1.19746.2.0.6004 - uncorrectableECCerror
1.3.6.1.4.1.19746.2.0.5005 - unsupportedACVoltage
1.3.6.1.4.1.19746.2.0.6521 - unsupportedConfigurationROL
1.3.6.1.4.1.19746.2.0.5095 - unsupportedDriveModel
1.3.6.1.4.1.19746.2.0.7001 - unsupportedEnclosurePSU
1.3.6.1.4.1.19746.2.0.10000 - unsupportedHardwareConfig
1.3.6.1.4.1.19746.2.0.7502 - unsupportedHardwareSpareSize
1.3.6.1.4.1.19746.2.0.5086 - unsupportedNIC
1.3.6.1.4.1.19746.2.0.6513 - unsupportedPowerSupply
1.3.6.1.4.1.19746.2.0.10001 - unsupportedSASDevice
1.3.6.1.4.1.19746.2.0.6516 - unsupportedSystemType
1.3.6.1.4.1.19746.2.0.6536 - unsupportedVirtualCPU
1.3.6.1.4.1.19746.2.0.7503 - unusableHostCertificate
1.3.6.1.4.1.19746.2.0.6017 - upgradeCompleted
1.3.6.1.4.1.19746.2.0.6510 - upgradeFailure
1.3.6.1.4.1.19746.2.0.6509 - upgradeInProgress
1.3.6.1.4.1.19746.2.0.10509 - vDiskSCSITargetMismatch
1.3.6.1.4.1.19746.2.0.10513 - vTLDisabled
1.3.6.1.4.1.19746.2.0.11106 - vTLEnabled
1.3.6.1.4.1.19746.2.0.11105 - voltageWarning
1.3.6.1.4.1.19746.2.0.5012
Groups and compliance
- alertsGroup
- artGroup
- basicNotificationsGroup
- cifsGroup
- cifsGroupRev1
- dataDomainMibCompliance
- dataDomainMibComplianceRev1
- dataDomainMibComplianceRev2
- dataDomainMibComplianceRev3
- dataDomainMibComplianceRev4
- dataDomainMibComplianceRev5
- ddboostGroup
- ddboostGroupRev1
- ddboostGroupRev2
- ddsystemGroup
- ddsystemGroupRev1
- enclosureGroup
- environmentalsGroup
- externalUnmanagedDiskStorageGroup
- fileSystemGroup
- fileSystemGroupRev1
- generatedNotificationsGroup
- highAvailabilityGroup
- internalDiskStorageGroup
- internalDiskStorageNotificationsGroup
- managedObjectsGroup
- mtreeGroup
- networkGroup
- nfsGroup
- nvramGroup
- quotaGroup
- replGroup
- scsitargetObjectGroup
- smtGroup
- statisticsGroup
- vtlGroup