DASAN-NOTIFICATION-V1
DASAN Co.,LTD.snmptranslate -m DASAN-NOTIFICATION-V1 -Tpsnmpwalk -v2c -c <community> -m DASAN-NOTIFICATION-V1 <host> 1.3.6.1.4.1.6296.0.0.1Imports
| DASAN-GEPON-MIB | dsPonCount, dsPonDirection, dsPonOltIndex, dsPonOnuIndex, dsPonOnuMacAddress, dsPonPortIndex, dsPonQueueIndex, dsPonState, dsPonTaggedLabel |
|---|---|
| DASAN-SMI | dasanEvents |
| DASAN-SWITCH-MIB | dsFanIndex, dsFanstatus, dsFreeMem, dsPortInstallStatus, dsPortModuleIndex, dsPortPortIndex, dsPowerIndex, dsPowerstatus, dsSubnetConfName, dsSwitchAtMacAddress, dsSwitchAtNetAddress, dsSwitchAtVID, dsSystemUpgradePath, dsSystemUpgradeStorage, dsTemperatureStatus, dsUserMacAddress1, dsUserMacAddress2, dsUserMacAddress3, dsUserMacAddress4 |
| DASAN-USER-MANAGEMENT-MIB | dsUserLoginIpAddress, dsUserLoginName |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-MIB | sysDescr, sysUpTime |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| !portInstalledTrap | 1.3.6.1.4.1.6296.0.0.1 | |||
notification portInstalled trap send when portInstallStatus is enabled.
| ||||
| !portRemovedTrap | 1.3.6.1.4.1.6296.0.0.2 | |||
notification portInstalled trap send when portInstallStatus is disabled.
| ||||
| !powerOkTrap | 1.3.6.1.4.1.6296.0.0.3 | |||
notification Power status OK trap when powerStatus change from disable to enable.
| ||||
| !powerFailTrap | 1.3.6.1.4.1.6296.0.0.4 | |||
notification Power status fail trap when powerStatus change from enable to disable.
| ||||
| !fanOkTrap | 1.3.6.1.4.1.6296.0.0.5 | |||
notification Fan status OK trap when fanStatus change from disable to enable.
| ||||
| !fanFailTrap | 1.3.6.1.4.1.6296.0.0.6 | |||
notification Fan status fail trap when fanStatus change from enable to disable.
| ||||
| !powerInstalledTrap | 1.3.6.1.4.1.6296.0.0.7 | |||
| !powerRemovedTrap | 1.3.6.1.4.1.6296.0.0.8 | |||
| !fanInstalledTrap | 1.3.6.1.4.1.6296.0.0.9 | |||
| !fanRemovedTrap | 1.3.6.1.4.1.6296.0.0.10 | |||
| !bcastOverTrap | 1.3.6.1.4.1.6296.0.0.11 | |||
notification Broadcast packet over trap when Rx broadcast packet is over the given limit.
| ||||
| !cpuLoadOverThresholdTrap | 1.3.6.1.4.1.6296.0.0.12 | |||
notification The cpuLoadoverThreshold trap is sentwhen cpuLoad is over the given limit.
| ||||
| !cpuLoadFallThresholdTrap | 1.3.6.1.4.1.6296.0.0.13 | |||
notification The cpuLoadfallThreshold trap is sent when cpuLoad fall under the given limit.
| ||||
| !dhcpLeaseShortageTrap | 1.3.6.1.4.1.6296.0.0.14 | |||
notification DHCP User IP pool shortage when User's DHCPDISCOVER message arrive.
| ||||
| !portOverThresholdTrap | 1.3.6.1.4.1.6296.0.0.15 | |||
notification Port traffic over HighThreshold trap when port traffic is over the given limit.
| ||||
| !portFallThresholdTrap | 1.3.6.1.4.1.6296.0.0.16 | |||
notification Port traffic fall under HighThreshold trap when port traffic fall under the given limit.
| ||||
| !temperatureOverThresholdTrap | 1.3.6.1.4.1.6296.0.0.17 | |||
notification TemperatureOverThreshold Trap is sent when temperature is over the certain threshold.
| ||||
| !systemRestartTrap | 1.3.6.1.4.1.6296.0.0.18 | |||
| !mfgdBlockedTrap | 1.3.6.1.4.1.6296.0.0.19 | |||
notification mfgdblocked Trap is sent when a certain mac address is denied by mac-flood-guard mechanism. | ||||
| !mfgdReleasedTrap | 1.3.6.1.4.1.6296.0.0.20 | |||
notification mfgdblocked Trap is sent when a certain mac address is permitted again by mac-flood-guard mechanism. | ||||
| !ipConflictTrap | 1.3.6.1.4.1.6296.0.0.21 | |||
notification ipConflict Trap is sent when a certain IP address is shared among different users. | ||||
| !dhcpIllegalEntryTrap | 1.3.6.1.4.1.6296.0.0.22 | |||
| !optionModuleInstalledTrap | 1.3.6.1.4.1.6296.0.0.23 | |||
| !optionModuleRemovedTrap | 1.3.6.1.4.1.6296.0.0.24 | |||
| !memoryOverThresholdTrap | 1.3.6.1.4.1.6296.0.0.25 | |||
notification Memory over HighThreshold trap when used memory size is over the given limit.
| ||||
| !memoryFallThresholdTrap | 1.3.6.1.4.1.6296.0.0.26 | |||
notification Memory fall under HighThreshold trap when used memory size fall under the given limit.
| ||||
| !slotInstalledTrap | 1.3.6.1.4.1.6296.0.0.27 | |||
| !slotRemovedTrap | 1.3.6.1.4.1.6296.0.0.28 | |||
| !slotStateChangeTrap | 1.3.6.1.4.1.6296.0.0.29 | |||
| !portCRCOverThreshold | 1.3.6.1.4.1.6296.0.0.30 | |||
| !portCRCFallThreshold | 1.3.6.1.4.1.6296.0.0.31 | |||
notification CRC Load fall under HighThreshold trap when crcLoad fall under the given limit.
| ||||
| !temperatureHighOverThreshold | 1.3.6.1.4.1.6296.0.0.32 | |||
notification The temperatureHighOverThreshold Trap is sent when temperature is over the high-threshold.
| ||||
| !temperatureHighFallThreshold | 1.3.6.1.4.1.6296.0.0.33 | |||
notification The temperatureHighFallThreshold Trap is sent when temperature fall the high-threshold.
| ||||
| !temperatureLowOverThreshold | 1.3.6.1.4.1.6296.0.0.34 | |||
notification The temperatureLowOverThreshold Trap is sent when 1st temperature is over the low-threshold.
| ||||
| !temperatureLowFallThreshold | 1.3.6.1.4.1.6296.0.0.35 | |||
notification The temperatureLowFallThreshold Trap is sent when temperature fall under the low-threshold.
| ||||
| !userLogIn | 1.3.6.1.4.1.6296.0.0.36 | |||
notification The user-login trap is sent when user login.
| ||||
| !userLogOut | 1.3.6.1.4.1.6296.0.0.37 | |||
notification The user-logout trap is sent when user logout.
| ||||
| !restoreFactory | 1.3.6.1.4.1.6296.0.0.38 | |||
notification The restoreFactory trap is sent when user initialize as factory defaults.
| ||||
| !cpuLoadHighOverThreshold | 1.3.6.1.4.1.6296.0.0.39 | |||
notification The cpuloadHighOverThreshold Trap is sent when cpuload is over the high-threshold.
| ||||
| !cpuLoadHighFallThreshold | 1.3.6.1.4.1.6296.0.0.40 | |||
notification The cpuloadHighFallThreshold Trap is sent when cpuload fall the high-threshold.
| ||||
| !cpuLoadLowOverThreshold | 1.3.6.1.4.1.6296.0.0.41 | |||
notification The cpuloadLowOverThreshold Trap is sent when 1st cpuload is over the low-threshold.
| ||||
| !cpuLoadLowFallThreshold | 1.3.6.1.4.1.6296.0.0.42 | |||
notification The cpuloadLowFallThreshold Trap is sent when cpuload fall under the low-threshold.
| ||||
| !igmpSnoopingChanged | 1.3.6.1.4.1.6296.0.0.43 | |||
notification
| ||||
| !dsSystemUpgradeChanged | 1.3.6.1.4.1.6296.0.0.44 | |||
| !adslAtucPerfLofsThreshTrap | 1.3.6.1.4.1.6296.0.0.51 | |||
| !adslAtucPerfLossThreshTrap | 1.3.6.1.4.1.6296.0.0.52 | |||
| !adslAtucPerfLprsThreshTrap | 1.3.6.1.4.1.6296.0.0.53 | |||
| !adslAtucPerfESsThreshTrap | 1.3.6.1.4.1.6296.0.0.54 | |||
| !adslAtucRateChangeTrap | 1.3.6.1.4.1.6296.0.0.55 | |||
| !adslAtucPerfLolsThreshTrap | 1.3.6.1.4.1.6296.0.0.56 | |||
| !adslAturPerfLofsThreshTrap | 1.3.6.1.4.1.6296.0.0.61 | |||
| !adslAturPerfLossThreshTrap | 1.3.6.1.4.1.6296.0.0.62 | |||
| !adslAturPerfLprsThreshTrap | 1.3.6.1.4.1.6296.0.0.63 | |||
| !adslAturPerfESsThreshTrap | 1.3.6.1.4.1.6296.0.0.64 | |||
| !vdslCPEChangeInfoTrap | 1.3.6.1.4.1.6296.0.0.65 | |||
notification Trap is sent with CPE Serial No., Mac Address of CPE, after CPE serial change. | ||||
| !cfgdBlocked | 1.3.6.1.4.1.6296.0.0.71 | |||
notification Cfgdblocked Trap is sent when a certain port is blocked by cpu-flood-guard mechanism.
| ||||
| !cfgdReleased | 1.3.6.1.4.1.6296.0.0.72 | |||
notification CfgdReleased Trap is sent when a certain port is non-blocked by cpu-flood-guard mechanism.
| ||||
| !cfgdOverThreshold | 1.3.6.1.4.1.6296.0.0.73 | |||
notification CfgdOverThreshold Trap is sent when a certain port is over the threshold by cpu-flood-guard mechanism.
| ||||
| !cfgdUnderThreshold | 1.3.6.1.4.1.6296.0.0.74 | |||
notification CfgdUnderThreshold Trap is sent when a certain port fall under the threshold by cpu-flood-guard mechanism
| ||||
| !sfgdBlocked | 1.3.6.1.4.1.6296.0.0.75 | |||
notification Sfgdblocked Trap is sent when a certain port is blocked by system-flood-guard mechanism.
| ||||
| !sfgdReleased | 1.3.6.1.4.1.6296.0.0.76 | |||
notification SfgdReleased Trap is sent when a certain port is non-blocked by system-flood-guard mechanism.
| ||||
| !sfgdOverThreshold | 1.3.6.1.4.1.6296.0.0.77 | |||
notification SfgdOverThreshold Trap is sent when a certain port is over the threshold by system-flood-guard mechanism.
| ||||
| !sfgdUnderThreshold | 1.3.6.1.4.1.6296.0.0.78 | |||
notification SfgdUnderThreshold Trap is sent when a certain port fall under the threshold by system-flood-guard mechanism
| ||||
| !ppsControlBlocked | 1.3.6.1.4.1.6296.0.0.79 | |||
notification ppsControlBlocked Trap is sent when a certain port is blocked by PPS-Control mechanism.
| ||||
| !ppsControlReleased | 1.3.6.1.4.1.6296.0.0.80 | |||
notification ppsControlReleased Trap is sent when a certain port is non-blocked by PPS-Control mechanism.
| ||||
| !ppsControlOverThreshold | 1.3.6.1.4.1.6296.0.0.81 | |||
notification ppsControlOverThreshold Trap is sent when a certain port is over the threshold by PPS-Control mechanism.
| ||||
| !ppsontrolUnderThreshold | 1.3.6.1.4.1.6296.0.0.82 | |||
notification ppsControlUnderThreshold Trap is sent when a certain port fall under the threshold by PPS-Control mechanism
| ||||
| !nosRemoteUpgradeRequest | 1.3.6.1.4.1.6296.0.0.83 | |||
notification This trap indicates that the system received nos-remote-upgrade command. | ||||
| !nosRemoteUpgradeSuccess | 1.3.6.1.4.1.6296.0.0.84 | |||
notification This trap indicates that the NOS succeeded to upgrade NOS. | ||||
| !nosRemoteUpgradeFailAbort | 1.3.6.1.4.1.6296.0.0.85 | |||
notification This trap indicates that the system failed to download NOS by user interrup. | ||||
| !nosRemoteUpgradeFailHeaderError | 1.3.6.1.4.1.6296.0.0.86 | |||
notification This trap indicates that the system failed to download NOS, for NOS header-error. | ||||
| !nosRemoteUpgradeFailDownloadError | 1.3.6.1.4.1.6296.0.0.87 | |||
notification This trap indicates that the system failed to download NOS, for NOS checksum-error. | ||||
| !nosRemoteUpgradeFailFlashError | 1.3.6.1.4.1.6296.0.0.88 | |||
notification This trap indicates that the system failed to download NOS, for flash operation. | ||||
| !nosRemoteUpgradeStart | 1.3.6.1.4.1.6296.0.0.89 | |||
notification This trap indicates that the upgrade NOS process was started. | ||||
| !systemDyingGasp | 1.3.6.1.4.1.6296.0.0.90 | |||
| !attackGuardBlock | 1.3.6.1.4.1.6296.0.0.91 | |||
notification This trap indicates that some port is blocked by attack-guard.
| ||||
| !attackGuardUnBlock | 1.3.6.1.4.1.6296.0.0.92 | |||
notification This trap indicates that some port is unblocked by attack-guard.
| ||||
| !fanPeriodicFault | 1.3.6.1.4.1.6296.0.0.93 | |||
notification This trap indicates the fan status is fault in some period.
| ||||
| !remoteOamDyingGasp | 1.3.6.1.4.1.6296.0.0.94 | |||
| !remoteOamDyingGaspRestoration | 1.3.6.1.4.1.6296.0.0.95 | |||
| !arpInspectInvalid | 1.3.6.1.4.1.6296.0.0.96 | |||
notification This trap indicates the ARP inspection is invalided.
| ||||
| !systemSwitchover | 1.3.6.1.4.1.6296.0.0.97 | |||
| !boardChangeState | 1.3.6.1.4.1.6296.0.0.98 | |||
notification This trap indicates the board state is changed. | ||||
| !clockModuleInstalled | 1.3.6.1.4.1.6296.0.0.105 | |||
notification clockModuleInstalled trap send when sleClockModuleInstallStatus is installed. | ||||
| !clockModuleRemoved | 1.3.6.1.4.1.6296.0.0.106 | |||
notification clockModuleRemoved trap send when sleClockModuleInstallStatus is removed. | ||||
| !clockModuleInitOk | 1.3.6.1.4.1.6296.0.0.107 | |||
notification clockModuleInitOk trap send when sleClockModuleInitStatus is ok. | ||||
| !clockModuleInitFail | 1.3.6.1.4.1.6296.0.0.108 | |||
notification clockModuleInitFail trap send when sleClockModuleInitStatus is failure. | ||||
| !interfaceAdminUp | 1.3.6.1.4.1.6296.0.0.109 | |||
| !interfaceAdminDown | 1.3.6.1.4.1.6296.0.0.110 | |||
| !powerMonEventDetected | 1.3.6.1.4.1.6296.0.0.111 | |||
notification This trap indicates the power monitoring detects voltage change of slot. | ||||
| !ntpConnectionFail | 1.3.6.1.4.1.6296.0.0.112 | |||
| !fanSpeedFallUnderThreshold | 1.3.6.1.4.1.6296.0.0.113 | |||
notification This trap indicates the fan speed is under the threshold.
| ||||
| !fanSpeedRisingOverThreshold | 1.3.6.1.4.1.6296.0.0.114 | |||
notification This trap indicates the fan speed is over the threshold.
| ||||
| !userLoginFail | 1.3.6.1.4.1.6296.0.0.115 | |||
| !bfdSessionStateChanged | 1.3.6.1.4.1.6296.0.0.116 | |||
notification This trap indicates that BFD session state is changed. | ||||
| !clockModuleOPModeChanged | 1.3.6.1.4.1.6296.0.0.117 | |||
notification This trap indicate that slot Operation mode is changed. | ||||
| !clockModuleRefrencesChanged | 1.3.6.1.4.1.6296.0.0.118 | |||
notification This trap indicate that slot reference ntr is changed. | ||||
| !portRxOverThreshold | 1.3.6.1.4.1.6296.0.0.121 | |||
notification Port Rx traffic over HighThreshold trap when port traffic is over the given limit.
| ||||
| !portRxFallThreshold | 1.3.6.1.4.1.6296.0.0.122 | |||
notification Port Rx traffic fall under HighThreshold trap when port traffic falls below the given limit.
| ||||
| !portTxOverThreshold | 1.3.6.1.4.1.6296.0.0.123 | |||
notification Port Tx traffic over HighThreshold trap when port traffic is over the given limit.
| ||||
| !portTxFallThreshold | 1.3.6.1.4.1.6296.0.0.124 | |||
notification Port Tx traffic fall under HighThreshold trap when port traffic falls below the given limit.
| ||||
| !clockModuleInSrcStatusChanged | 1.3.6.1.4.1.6296.0.0.125 | |||
notification This trap indicate that BFD reference ntr is changed. | ||||
| !clockModuleInSrcAISStatusChanged | 1.3.6.1.4.1.6296.0.0.126 | |||
notification This trap indicate that BFD reference ntr is changed. | ||||
| !clockModuleInSrcLoSStatusChanged | 1.3.6.1.4.1.6296.0.0.127 | |||
notification This trap indicate that BFD reference ntr is changed. | ||||
| !clockModuleInSrcLDSCStatus | 1.3.6.1.4.1.6296.0.0.128 | |||
notification This trap indicate that BFD reference ntr is changed. | ||||
| !clockModuleInSrcNtrClockchanged | 1.3.6.1.4.1.6296.0.0.129 | |||
notification This trap indicate that BFD reference ntr is changed. | ||||
| !ponLinkFault | 1.3.6.1.4.1.6296.0.0.151 | |||
notification ONU reports a Link Fault via the flag in the 802.3ah OAM header.No further information about the fault is available.. | ||||
| !ponLos | 1.3.6.1.4.1.6296.0.0.152 | |||
notification Loss of Signal is detected by the PHY device for OLT Network interface, and PON interfaces on the OLT and ONU. | ||||
| !ponTransmitFail | 1.3.6.1.4.1.6296.0.0.153 | |||
notification Transmitted output does not match input, as reported by EPON optics | ||||
| !ponTransmitDegrade | 1.3.6.1.4.1.6296.0.0.154 | |||
notification Transmitted output has a high error level, but not so high as to cause - Failure. Optionallyreported by EPON optical module.. | ||||
| !ponQueueOverflow | 1.3.6.1.4.1.6296.0.0.155 | |||
notification One of the queues for the link has dropped frames due to becoming full | ||||
| !ponMacLearningTableOverflow | 1.3.6.1.4.1.6296.0.0.156 | |||
notification MAC address learning table is full, not in overwrite mode, and a new MAC address wasencountered | ||||
| !ponDuplicateMacRegistration | 1.3.6.1.4.1.6296.0.0.157 | |||
notification MPCP register request received for MAC that is registered and in-service | ||||
| !ponReportTimeout | 1.3.6.1.4.1.6296.0.0.158 | |||
notification ONU does not respond to grants from the OLT | ||||
| !ponGateTimeout | 1.3.6.1.4.1.6296.0.0.159 | |||
notification Excessive interval between MPCP gates. | ||||
| !ponOAMKeepaliveTimeout | 1.3.6.1.4.1.6296.0.0.160 | |||
notification OAM KeepaliveTimeout - OAM layer does not receive periodic messages from its peer | ||||
| !ponKeyExchangeFailure | 1.3.6.1.4.1.6296.0.0.161 | |||
notification The link peer has failed to generate a new key message, or to switch to the new key, in the timeallotted by the key exchange timer for this link. Encryption remains in force using the old key, and the key exchange process continues.The alarm will clear when a new key is established. | ||||
| !ponAutoNegotiation | 1.3.6.1.4.1.6296.0.0.162 | |||
notification OLT Network port fails to auto-negotiate with the peer (if auto-negotiation feature is enabled). | ||||
| !ponLinkLoopback | 1.3.6.1.4.1.6296.0.0.163 | |||
notification The link is currently in the loopback state | ||||
| !ponStandardDyingGasp | 1.3.6.1.4.1.6296.0.0.164 | |||
notification ONU reports Dying Gasp via that bit in 802.3ah OAM header | ||||
| !ponPowerFail | 1.3.6.1.4.1.6296.0.0.165 | |||
notification Power supply failure | ||||
| !ponTemperature | 1.3.6.1.4.1.6296.0.0.166 | |||
notification Operating temperature range exceeded | ||||
| !ponAuthenticationInformationUnavailable | 1.3.6.1.4.1.6296.0.0.167 | |||
notification ONU is configured to use external authentication device, and that device is not present | ||||
| !ponOctetsTransferred | 1.3.6.1.4.1.6296.0.0.171 | |||
notification Octets Transferred | ||||
| !ponTotalFramesTransferred | 1.3.6.1.4.1.6296.0.0.172 | |||
notification Total frames transferred | ||||
| !ponUnicastFramesTransferred | 1.3.6.1.4.1.6296.0.0.173 | |||
notification Unicast frames transferred | ||||
| !ponBroadcastFramesTransferred | 1.3.6.1.4.1.6296.0.0.174 | |||
notification Broadcast frames transferred | ||||
| !ponMulticastFramesTransferred | 1.3.6.1.4.1.6296.0.0.175 | |||
notification Multicast frames transferred | ||||
| !ponCRC32Errors | 1.3.6.1.4.1.6296.0.0.176 | |||
notification CRC-32 Errors | ||||
| !ponUndersizeFrames | 1.3.6.1.4.1.6296.0.0.177 | |||
notification Undersize Frames | ||||
| !ponOversizeFrames | 1.3.6.1.4.1.6296.0.0.178 | |||
notification Oversize Frames | ||||
| !ponCollisions | 1.3.6.1.4.1.6296.0.0.179 | |||
notification Collisions | ||||
| !pon64OctetFrames | 1.3.6.1.4.1.6296.0.0.180 | |||
notification 64 Octet Frames | ||||
| !pon127OctetFrames | 1.3.6.1.4.1.6296.0.0.181 | |||
notification 65-127 Octet Frames | ||||
| !pon255OctetFrames | 1.3.6.1.4.1.6296.0.0.182 | |||
notification 128-255 Octet Frames | ||||
| !pon511OctetFrames | 1.3.6.1.4.1.6296.0.0.183 | |||
notification 256-511 Octet Frames | ||||
| !pon1023OctetFrames | 1.3.6.1.4.1.6296.0.0.184 | |||
notification 512-1023 Octet Frames | ||||
| !pon1518OctetFrames | 1.3.6.1.4.1.6296.0.0.185 | |||
notification 1024-1518 Octet Frames | ||||
| !pon1519OverOctetFrames | 1.3.6.1.4.1.6296.0.0.186 | |||
notification 1519+ Octet Frames | ||||
| !ponFramesDropped | 1.3.6.1.4.1.6296.0.0.187 | |||
notification Frames dropped | ||||
| !ponOctetsDropped | 1.3.6.1.4.1.6296.0.0.188 | |||
notification Octets dropped | ||||
| !ponOctetsDelayed | 1.3.6.1.4.1.6296.0.0.189 | |||
notification Octets delayed | ||||
| !ponOctetsGranted | 1.3.6.1.4.1.6296.0.0.190 | |||
notification Octets granted | ||||
| !ponOctetsGrantedButUnused | 1.3.6.1.4.1.6296.0.0.191 | |||
notification Octets granted but unused | ||||
| !ponMaximumDelay | 1.3.6.1.4.1.6296.0.0.192 | |||
notification Maximum Delay (units of 100usec) | ||||
| !ponCRC8Errors | 1.3.6.1.4.1.6296.0.0.193 | |||
notification CRC-8 (preamble) Errors | ||||
| !ponLineCodeErrors | 1.3.6.1.4.1.6296.0.0.194 | |||
notification Line code errors | ||||
| !ponPauseFrames | 1.3.6.1.4.1.6296.0.0.195 | |||
notification Pause Frames | ||||
| !ponErroredFrameSeconds | 1.3.6.1.4.1.6296.0.0.196 | |||
notification Errored Frame Seconds | ||||
| !ponErroredFramePeriod | 1.3.6.1.4.1.6296.0.0.197 | |||
notification Errored Frame Period | ||||
| !ponErroredFrameSecondsSummary | 1.3.6.1.4.1.6296.0.0.198 | |||
notification Errored Frame Seconds Summary | ||||
| !gponOnuRegistered | 1.3.6.1.4.1.6296.0.0.200 | |||
notification Registered Onu Information | ||||
| !gponOnuDeregistered | 1.3.6.1.4.1.6296.0.0.201 | |||
notification Deregistered Onu Information | ||||
| !swWatchdogDetectError | 1.3.6.1.4.1.6296.0.0.202 | |||
| !swWatchdogClearError | 1.3.6.1.4.1.6296.0.0.203 | |||
| !swWatchdogNormalState | 1.3.6.1.4.1.6296.0.0.204 | |||
| !swWatchdogAbnormalState | 1.3.6.1.4.1.6296.0.0.205 | |||
| !gponOnuUpgradeCompleted | 1.3.6.1.4.1.6296.0.0.206 | |||
| !gponOltCableDown | 1.3.6.1.4.1.6296.0.0.207 | |||
| !gponOnuAutoToManual | 1.3.6.1.4.1.6296.0.0.208 | |||
| !slotActionEvent | 1.3.6.1.4.1.6296.0.0.209 | |||
notification This trap indicates the slot action event | ||||
| !slotStateChanged | 1.3.6.1.4.1.6296.0.0.210 | |||
notification This trap indicates the slot state is changed | ||||
| !gponNoAuthONU | 1.3.6.1.4.1.6296.0.0.211 | |||
| !gponDuplicateONU | 1.3.6.1.4.1.6296.0.0.212 | |||
| !gponDyingGasp | 1.3.6.1.4.1.6296.0.0.213 | |||
| !gponRogueOnu | 1.3.6.1.4.1.6296.0.0.214 | |||
| !gponOnuBatteryEvent | 1.3.6.1.4.1.6296.0.0.215 | |||
| !gponOnuBatteryEventCleared | 1.3.6.1.4.1.6296.0.0.216 | |||
| !gponOnuPortOperStatus | 1.3.6.1.4.1.6296.0.0.217 | |||
notification This trap indicates state of ONU Port Operation. | ||||
| !gponTransceiverChanged | 1.3.6.1.4.1.6296.0.0.218 | |||
notification This trap indicates GPON transceiver changed. | ||||
| !gponOltLosOn | 1.3.6.1.4.1.6296.0.0.219 | |||
| !gponOltLosOff | 1.3.6.1.4.1.6296.0.0.220 | |||
| !gponOltLosiOn | 1.3.6.1.4.1.6296.0.0.221 | |||
notification This trap indicates state of OLT Log Of Signal for ONUi (on).
| ||||
| !gponOltLosiOff | 1.3.6.1.4.1.6296.0.0.222 | |||
notification This trap indicates state of OLT Log Of Signal for ONUi (off).
| ||||
| !gponDyingGaspOn | 1.3.6.1.4.1.6296.0.0.223 | |||
notification This trap indicates Dying Gasp of GPON ONU (on).
| ||||
| !gponDyingGaspOff | 1.3.6.1.4.1.6296.0.0.224 | |||
notification This trap indicates Dying Gasp of GPON ONU (off).
| ||||
| !slotErrorLEDChanged | 1.3.6.1.4.1.6296.0.0.225 | |||
| !nmsConnectionTypeChanged | 1.3.6.1.4.1.6296.0.0.226 | |||
| !gponOntOSUpgradeStatus | 1.3.6.1.4.1.6296.0.0.227 | |||
notification This trap indicates ONT OS upgrade status changes. | ||||
| !gponOntBLUpgradeStatus | 1.3.6.1.4.1.6296.0.0.228 | |||
notification This trap indicates ONT BL upgrade status changes. | ||||
| !gponOntRxPowerLoss | 1.3.6.1.4.1.6296.0.0.229 | |||
| !gponOntRxPowerDetected | 1.3.6.1.4.1.6296.0.0.230 | |||
| !gponOnuTemperatureHighOverThreshold | 1.3.6.1.4.1.6296.0.0.231 | |||
notification This trap indicates the temperature of ONU is over high threshold.
| ||||
| !gponOnuTemperatureHighFallThreshold | 1.3.6.1.4.1.6296.0.0.232 | |||
notification This trap indicates the temperature of ONU falls under high threshold.
| ||||
| !gponOnuTemperatureLowOverThreshold | 1.3.6.1.4.1.6296.0.0.233 | |||
notification This trap indicates the temperature of ONU is over low threshold.
| ||||
| !gponOnuTemperatureLowFallThreshold | 1.3.6.1.4.1.6296.0.0.234 | |||
notification This trap indicates the temperature of ONU falls under low threshold.
| ||||
| !gponOnuCpuOverThreshold | 1.3.6.1.4.1.6296.0.0.235 | |||
notification This trap indicates the CPU-load of ONU is over threshold.
| ||||
| !gponOnuCpuFallThreshold | 1.3.6.1.4.1.6296.0.0.236 | |||
notification This trap indicates the CPU-load of ONU falls under threshold.
| ||||
| !gponOnuMemoryOverThreshold | 1.3.6.1.4.1.6296.0.0.237 | |||
notification This trap indicates the memory-utilization of ONU is over threshold.
| ||||
| !gponOnuMemoryFallThreshold | 1.3.6.1.4.1.6296.0.0.238 | |||
notification This trap indicates the memory-utilization of ONU falls under threshold.
| ||||
| !gponOnuI2cFail | 1.3.6.1.4.1.6296.0.0.239 | |||
| !gponOnuRxOpticPowerLowThreshAlarmOn | 1.3.6.1.4.1.6296.0.0.240 | |||
notification This trap indicates that ONU's low threshold Rx Optic power Alarm is On.
| ||||
| !gponOnuRxOpticPowerLowThreshAlarmOff | 1.3.6.1.4.1.6296.0.0.241 | |||
notification This trap indicates that ONU's low threshold Rx Optic power Alarm is Off.
| ||||
| !gponOnuRxOpticPowerHighThreshAlarmOn | 1.3.6.1.4.1.6296.0.0.242 | |||
notification This trap indicates that ONU's high threshold Rx Optic power Alarm is On.
| ||||
| !gponOnuRxOpticPowerHighThreshAlarmOff | 1.3.6.1.4.1.6296.0.0.243 | |||
notification This trap indicates that ONU's high threshold Rx Optic power Alarm is Off.
| ||||
| !gponOltLOFIOn | 1.3.6.1.4.1.6296.0.0.244 | |||
| !gponOltLOFIOff | 1.3.6.1.4.1.6296.0.0.245 | |||
| !gponOltDOWOn | 1.3.6.1.4.1.6296.0.0.246 | |||
| !gponOltDOWOff | 1.3.6.1.4.1.6296.0.0.247 | |||
| !gponOltSFOn | 1.3.6.1.4.1.6296.0.0.248 | |||
| !gponOltSFOff | 1.3.6.1.4.1.6296.0.0.249 | |||
| !gponOltSDOn | 1.3.6.1.4.1.6296.0.0.250 | |||
| !gponOltSDOff | 1.3.6.1.4.1.6296.0.0.251 | |||
| !gponOltLCDGIOn | 1.3.6.1.4.1.6296.0.0.252 | |||
| !gponOltLCDGIOff | 1.3.6.1.4.1.6296.0.0.253 | |||
| !gponOltRDOn | 1.3.6.1.4.1.6296.0.0.254 | |||
| !gponOltRDOff | 1.3.6.1.4.1.6296.0.0.255 | |||
| !gponOltSUFOn | 1.3.6.1.4.1.6296.0.0.256 | |||
| !gponOltSUFOff | 1.3.6.1.4.1.6296.0.0.257 | |||
| !gponOltLOAOn | 1.3.6.1.4.1.6296.0.0.258 | |||
| !gponOltLOAOff | 1.3.6.1.4.1.6296.0.0.259 | |||
| !gponOltLOAMIOn | 1.3.6.1.4.1.6296.0.0.260 | |||
| !gponOltLOAMIOff | 1.3.6.1.4.1.6296.0.0.261 | |||
| !gponOltMEMOn | 1.3.6.1.4.1.6296.0.0.262 | |||
| !gponOltMEMOff | 1.3.6.1.4.1.6296.0.0.263 | |||
| !gponOltPEEOn | 1.3.6.1.4.1.6296.0.0.264 | |||
| !gponOltPEEOff | 1.3.6.1.4.1.6296.0.0.265 | |||
| !gponOltPSTOn | 1.3.6.1.4.1.6296.0.0.266 | |||
| !gponOltPSTOff | 1.3.6.1.4.1.6296.0.0.267 | |||
| !gponOltERROn | 1.3.6.1.4.1.6296.0.0.268 | |||
| !gponOltERROff | 1.3.6.1.4.1.6296.0.0.269 | |||
| !gponOltREIOn | 1.3.6.1.4.1.6296.0.0.270 | |||
| !gponOltREIOff | 1.3.6.1.4.1.6296.0.0.271 | |||
Traps / Notifications
- adslAtucPerfESsThreshTrap
1.3.6.1.4.1.6296.0.0.54 - adslAtucPerfLofsThreshTrap
1.3.6.1.4.1.6296.0.0.51 - adslAtucPerfLolsThreshTrap
1.3.6.1.4.1.6296.0.0.56 - adslAtucPerfLossThreshTrap
1.3.6.1.4.1.6296.0.0.52 - adslAtucPerfLprsThreshTrap
1.3.6.1.4.1.6296.0.0.53 - adslAtucRateChangeTrap
1.3.6.1.4.1.6296.0.0.55 - adslAturPerfESsThreshTrap
1.3.6.1.4.1.6296.0.0.64 - adslAturPerfLofsThreshTrap
1.3.6.1.4.1.6296.0.0.61 - adslAturPerfLossThreshTrap
1.3.6.1.4.1.6296.0.0.62 - adslAturPerfLprsThreshTrap
1.3.6.1.4.1.6296.0.0.63 - arpInspectInvalid
1.3.6.1.4.1.6296.0.0.96 - attackGuardBlock
1.3.6.1.4.1.6296.0.0.91 - attackGuardUnBlock
1.3.6.1.4.1.6296.0.0.92 - bcastOverTrap
1.3.6.1.4.1.6296.0.0.11 - bfdSessionStateChanged
1.3.6.1.4.1.6296.0.0.116 - boardChangeState
1.3.6.1.4.1.6296.0.0.98 - cfgdBlocked
1.3.6.1.4.1.6296.0.0.71 - cfgdOverThreshold
1.3.6.1.4.1.6296.0.0.73 - cfgdReleased
1.3.6.1.4.1.6296.0.0.72 - cfgdUnderThreshold
1.3.6.1.4.1.6296.0.0.74 - clockModuleInSrcAISStatusChanged
1.3.6.1.4.1.6296.0.0.126 - clockModuleInSrcLDSCStatus
1.3.6.1.4.1.6296.0.0.128 - clockModuleInSrcLoSStatusChanged
1.3.6.1.4.1.6296.0.0.127 - clockModuleInSrcNtrClockchanged
1.3.6.1.4.1.6296.0.0.129 - clockModuleInSrcStatusChanged
1.3.6.1.4.1.6296.0.0.125 - clockModuleInitFail
1.3.6.1.4.1.6296.0.0.108 - clockModuleInitOk
1.3.6.1.4.1.6296.0.0.107 - clockModuleInstalled
1.3.6.1.4.1.6296.0.0.105 - clockModuleOPModeChanged
1.3.6.1.4.1.6296.0.0.117 - clockModuleRefrencesChanged
1.3.6.1.4.1.6296.0.0.118 - clockModuleRemoved
1.3.6.1.4.1.6296.0.0.106 - cpuLoadFallThresholdTrap
1.3.6.1.4.1.6296.0.0.13 - cpuLoadHighFallThreshold
1.3.6.1.4.1.6296.0.0.40 - cpuLoadHighOverThreshold
1.3.6.1.4.1.6296.0.0.39 - cpuLoadLowFallThreshold
1.3.6.1.4.1.6296.0.0.42 - cpuLoadLowOverThreshold
1.3.6.1.4.1.6296.0.0.41 - cpuLoadOverThresholdTrap
1.3.6.1.4.1.6296.0.0.12 - dhcpIllegalEntryTrap
1.3.6.1.4.1.6296.0.0.22 - dhcpLeaseShortageTrap
1.3.6.1.4.1.6296.0.0.14 - dsSystemUpgradeChanged
1.3.6.1.4.1.6296.0.0.44 - fanFailTrap
1.3.6.1.4.1.6296.0.0.6 - fanInstalledTrap
1.3.6.1.4.1.6296.0.0.9 - fanOkTrap
1.3.6.1.4.1.6296.0.0.5 - fanPeriodicFault
1.3.6.1.4.1.6296.0.0.93 - fanRemovedTrap
1.3.6.1.4.1.6296.0.0.10 - fanSpeedFallUnderThreshold
1.3.6.1.4.1.6296.0.0.113 - fanSpeedRisingOverThreshold
1.3.6.1.4.1.6296.0.0.114 - gponDuplicateONU
1.3.6.1.4.1.6296.0.0.212 - gponDyingGasp
1.3.6.1.4.1.6296.0.0.213 - gponDyingGaspOff
1.3.6.1.4.1.6296.0.0.224 - gponDyingGaspOn
1.3.6.1.4.1.6296.0.0.223 - gponNoAuthONU
1.3.6.1.4.1.6296.0.0.211 - gponOltCableDown
1.3.6.1.4.1.6296.0.0.207 - gponOltDOWOff
1.3.6.1.4.1.6296.0.0.247 - gponOltDOWOn
1.3.6.1.4.1.6296.0.0.246 - gponOltERROff
1.3.6.1.4.1.6296.0.0.269 - gponOltERROn
1.3.6.1.4.1.6296.0.0.268 - gponOltLCDGIOff
1.3.6.1.4.1.6296.0.0.253 - gponOltLCDGIOn
1.3.6.1.4.1.6296.0.0.252 - gponOltLOAMIOff
1.3.6.1.4.1.6296.0.0.261 - gponOltLOAMIOn
1.3.6.1.4.1.6296.0.0.260 - gponOltLOAOff
1.3.6.1.4.1.6296.0.0.259 - gponOltLOAOn
1.3.6.1.4.1.6296.0.0.258 - gponOltLOFIOff
1.3.6.1.4.1.6296.0.0.245 - gponOltLOFIOn
1.3.6.1.4.1.6296.0.0.244 - gponOltLosOff
1.3.6.1.4.1.6296.0.0.220 - gponOltLosOn
1.3.6.1.4.1.6296.0.0.219 - gponOltLosiOff
1.3.6.1.4.1.6296.0.0.222 - gponOltLosiOn
1.3.6.1.4.1.6296.0.0.221 - gponOltMEMOff
1.3.6.1.4.1.6296.0.0.263 - gponOltMEMOn
1.3.6.1.4.1.6296.0.0.262 - gponOltPEEOff
1.3.6.1.4.1.6296.0.0.265 - gponOltPEEOn
1.3.6.1.4.1.6296.0.0.264 - gponOltPSTOff
1.3.6.1.4.1.6296.0.0.267 - gponOltPSTOn
1.3.6.1.4.1.6296.0.0.266 - gponOltRDOff
1.3.6.1.4.1.6296.0.0.255 - gponOltRDOn
1.3.6.1.4.1.6296.0.0.254 - gponOltREIOff
1.3.6.1.4.1.6296.0.0.271 - gponOltREIOn
1.3.6.1.4.1.6296.0.0.270 - gponOltSDOff
1.3.6.1.4.1.6296.0.0.251 - gponOltSDOn
1.3.6.1.4.1.6296.0.0.250 - gponOltSFOff
1.3.6.1.4.1.6296.0.0.249 - gponOltSFOn
1.3.6.1.4.1.6296.0.0.248 - gponOltSUFOff
1.3.6.1.4.1.6296.0.0.257 - gponOltSUFOn
1.3.6.1.4.1.6296.0.0.256 - gponOntBLUpgradeStatus
1.3.6.1.4.1.6296.0.0.228 - gponOntOSUpgradeStatus
1.3.6.1.4.1.6296.0.0.227 - gponOntRxPowerDetected
1.3.6.1.4.1.6296.0.0.230 - gponOntRxPowerLoss
1.3.6.1.4.1.6296.0.0.229 - gponOnuAutoToManual
1.3.6.1.4.1.6296.0.0.208 - gponOnuBatteryEvent
1.3.6.1.4.1.6296.0.0.215 - gponOnuBatteryEventCleared
1.3.6.1.4.1.6296.0.0.216 - gponOnuCpuFallThreshold
1.3.6.1.4.1.6296.0.0.236 - gponOnuCpuOverThreshold
1.3.6.1.4.1.6296.0.0.235 - gponOnuDeregistered
1.3.6.1.4.1.6296.0.0.201 - gponOnuI2cFail
1.3.6.1.4.1.6296.0.0.239 - gponOnuMemoryFallThreshold
1.3.6.1.4.1.6296.0.0.238 - gponOnuMemoryOverThreshold
1.3.6.1.4.1.6296.0.0.237 - gponOnuPortOperStatus
1.3.6.1.4.1.6296.0.0.217 - gponOnuRegistered
1.3.6.1.4.1.6296.0.0.200 - gponOnuRxOpticPowerHighThreshAlarmOff
1.3.6.1.4.1.6296.0.0.243 - gponOnuRxOpticPowerHighThreshAlarmOn
1.3.6.1.4.1.6296.0.0.242 - gponOnuRxOpticPowerLowThreshAlarmOff
1.3.6.1.4.1.6296.0.0.241 - gponOnuRxOpticPowerLowThreshAlarmOn
1.3.6.1.4.1.6296.0.0.240 - gponOnuTemperatureHighFallThreshold
1.3.6.1.4.1.6296.0.0.232 - gponOnuTemperatureHighOverThreshold
1.3.6.1.4.1.6296.0.0.231 - gponOnuTemperatureLowFallThreshold
1.3.6.1.4.1.6296.0.0.234 - gponOnuTemperatureLowOverThreshold
1.3.6.1.4.1.6296.0.0.233 - gponOnuUpgradeCompleted
1.3.6.1.4.1.6296.0.0.206 - gponRogueOnu
1.3.6.1.4.1.6296.0.0.214 - gponTransceiverChanged
1.3.6.1.4.1.6296.0.0.218 - igmpSnoopingChanged
1.3.6.1.4.1.6296.0.0.43 - interfaceAdminDown
1.3.6.1.4.1.6296.0.0.110 - interfaceAdminUp
1.3.6.1.4.1.6296.0.0.109 - ipConflictTrap
1.3.6.1.4.1.6296.0.0.21 - memoryFallThresholdTrap
1.3.6.1.4.1.6296.0.0.26 - memoryOverThresholdTrap
1.3.6.1.4.1.6296.0.0.25 - mfgdBlockedTrap
1.3.6.1.4.1.6296.0.0.19 - mfgdReleasedTrap
1.3.6.1.4.1.6296.0.0.20 - nmsConnectionTypeChanged
1.3.6.1.4.1.6296.0.0.226 - nosRemoteUpgradeFailAbort
1.3.6.1.4.1.6296.0.0.85 - nosRemoteUpgradeFailDownloadError
1.3.6.1.4.1.6296.0.0.87 - nosRemoteUpgradeFailFlashError
1.3.6.1.4.1.6296.0.0.88 - nosRemoteUpgradeFailHeaderError
1.3.6.1.4.1.6296.0.0.86 - nosRemoteUpgradeRequest
1.3.6.1.4.1.6296.0.0.83 - nosRemoteUpgradeStart
1.3.6.1.4.1.6296.0.0.89 - nosRemoteUpgradeSuccess
1.3.6.1.4.1.6296.0.0.84 - ntpConnectionFail
1.3.6.1.4.1.6296.0.0.112 - optionModuleInstalledTrap
1.3.6.1.4.1.6296.0.0.23 - optionModuleRemovedTrap
1.3.6.1.4.1.6296.0.0.24 - pon1023OctetFrames
1.3.6.1.4.1.6296.0.0.184 - pon127OctetFrames
1.3.6.1.4.1.6296.0.0.181 - pon1518OctetFrames
1.3.6.1.4.1.6296.0.0.185 - pon1519OverOctetFrames
1.3.6.1.4.1.6296.0.0.186 - pon255OctetFrames
1.3.6.1.4.1.6296.0.0.182 - pon511OctetFrames
1.3.6.1.4.1.6296.0.0.183 - pon64OctetFrames
1.3.6.1.4.1.6296.0.0.180 - ponAuthenticationInformationUnavailable
1.3.6.1.4.1.6296.0.0.167 - ponAutoNegotiation
1.3.6.1.4.1.6296.0.0.162 - ponBroadcastFramesTransferred
1.3.6.1.4.1.6296.0.0.174 - ponCRC32Errors
1.3.6.1.4.1.6296.0.0.176 - ponCRC8Errors
1.3.6.1.4.1.6296.0.0.193 - ponCollisions
1.3.6.1.4.1.6296.0.0.179 - ponDuplicateMacRegistration
1.3.6.1.4.1.6296.0.0.157 - ponErroredFramePeriod
1.3.6.1.4.1.6296.0.0.197 - ponErroredFrameSeconds
1.3.6.1.4.1.6296.0.0.196 - ponErroredFrameSecondsSummary
1.3.6.1.4.1.6296.0.0.198 - ponFramesDropped
1.3.6.1.4.1.6296.0.0.187 - ponGateTimeout
1.3.6.1.4.1.6296.0.0.159 - ponKeyExchangeFailure
1.3.6.1.4.1.6296.0.0.161 - ponLineCodeErrors
1.3.6.1.4.1.6296.0.0.194 - ponLinkFault
1.3.6.1.4.1.6296.0.0.151 - ponLinkLoopback
1.3.6.1.4.1.6296.0.0.163 - ponLos
1.3.6.1.4.1.6296.0.0.152 - ponMacLearningTableOverflow
1.3.6.1.4.1.6296.0.0.156 - ponMaximumDelay
1.3.6.1.4.1.6296.0.0.192 - ponMulticastFramesTransferred
1.3.6.1.4.1.6296.0.0.175 - ponOAMKeepaliveTimeout
1.3.6.1.4.1.6296.0.0.160 - ponOctetsDelayed
1.3.6.1.4.1.6296.0.0.189 - ponOctetsDropped
1.3.6.1.4.1.6296.0.0.188 - ponOctetsGranted
1.3.6.1.4.1.6296.0.0.190 - ponOctetsGrantedButUnused
1.3.6.1.4.1.6296.0.0.191 - ponOctetsTransferred
1.3.6.1.4.1.6296.0.0.171 - ponOversizeFrames
1.3.6.1.4.1.6296.0.0.178 - ponPauseFrames
1.3.6.1.4.1.6296.0.0.195 - ponPowerFail
1.3.6.1.4.1.6296.0.0.165 - ponQueueOverflow
1.3.6.1.4.1.6296.0.0.155 - ponReportTimeout
1.3.6.1.4.1.6296.0.0.158 - ponStandardDyingGasp
1.3.6.1.4.1.6296.0.0.164 - ponTemperature
1.3.6.1.4.1.6296.0.0.166 - ponTotalFramesTransferred
1.3.6.1.4.1.6296.0.0.172 - ponTransmitDegrade
1.3.6.1.4.1.6296.0.0.154 - ponTransmitFail
1.3.6.1.4.1.6296.0.0.153 - ponUndersizeFrames
1.3.6.1.4.1.6296.0.0.177 - ponUnicastFramesTransferred
1.3.6.1.4.1.6296.0.0.173 - portCRCFallThreshold
1.3.6.1.4.1.6296.0.0.31 - portCRCOverThreshold
1.3.6.1.4.1.6296.0.0.30 - portFallThresholdTrap
1.3.6.1.4.1.6296.0.0.16 - portInstalledTrap
1.3.6.1.4.1.6296.0.0.1 - portOverThresholdTrap
1.3.6.1.4.1.6296.0.0.15 - portRemovedTrap
1.3.6.1.4.1.6296.0.0.2 - portRxFallThreshold
1.3.6.1.4.1.6296.0.0.122 - portRxOverThreshold
1.3.6.1.4.1.6296.0.0.121 - portTxFallThreshold
1.3.6.1.4.1.6296.0.0.124 - portTxOverThreshold
1.3.6.1.4.1.6296.0.0.123 - powerFailTrap
1.3.6.1.4.1.6296.0.0.4 - powerInstalledTrap
1.3.6.1.4.1.6296.0.0.7 - powerMonEventDetected
1.3.6.1.4.1.6296.0.0.111 - powerOkTrap
1.3.6.1.4.1.6296.0.0.3 - powerRemovedTrap
1.3.6.1.4.1.6296.0.0.8 - ppsControlBlocked
1.3.6.1.4.1.6296.0.0.79 - ppsControlOverThreshold
1.3.6.1.4.1.6296.0.0.81 - ppsControlReleased
1.3.6.1.4.1.6296.0.0.80 - ppsontrolUnderThreshold
1.3.6.1.4.1.6296.0.0.82 - remoteOamDyingGasp
1.3.6.1.4.1.6296.0.0.94 - remoteOamDyingGaspRestoration
1.3.6.1.4.1.6296.0.0.95 - restoreFactory
1.3.6.1.4.1.6296.0.0.38 - sfgdBlocked
1.3.6.1.4.1.6296.0.0.75 - sfgdOverThreshold
1.3.6.1.4.1.6296.0.0.77 - sfgdReleased
1.3.6.1.4.1.6296.0.0.76 - sfgdUnderThreshold
1.3.6.1.4.1.6296.0.0.78 - slotActionEvent
1.3.6.1.4.1.6296.0.0.209 - slotErrorLEDChanged
1.3.6.1.4.1.6296.0.0.225 - slotInstalledTrap
1.3.6.1.4.1.6296.0.0.27 - slotRemovedTrap
1.3.6.1.4.1.6296.0.0.28 - slotStateChangeTrap
1.3.6.1.4.1.6296.0.0.29 - slotStateChanged
1.3.6.1.4.1.6296.0.0.210 - swWatchdogAbnormalState
1.3.6.1.4.1.6296.0.0.205 - swWatchdogClearError
1.3.6.1.4.1.6296.0.0.203 - swWatchdogDetectError
1.3.6.1.4.1.6296.0.0.202 - swWatchdogNormalState
1.3.6.1.4.1.6296.0.0.204 - systemDyingGasp
1.3.6.1.4.1.6296.0.0.90 - systemRestartTrap
1.3.6.1.4.1.6296.0.0.18 - systemSwitchover
1.3.6.1.4.1.6296.0.0.97 - temperatureHighFallThreshold
1.3.6.1.4.1.6296.0.0.33 - temperatureHighOverThreshold
1.3.6.1.4.1.6296.0.0.32 - temperatureLowFallThreshold
1.3.6.1.4.1.6296.0.0.35 - temperatureLowOverThreshold
1.3.6.1.4.1.6296.0.0.34 - temperatureOverThresholdTrap
1.3.6.1.4.1.6296.0.0.17 - userLogIn
1.3.6.1.4.1.6296.0.0.36 - userLogOut
1.3.6.1.4.1.6296.0.0.37 - userLoginFail
1.3.6.1.4.1.6296.0.0.115 - vdslCPEChangeInfoTrap
1.3.6.1.4.1.6296.0.0.65