CPS-MIB
Cyber Power System Inc.snmptranslate -m CPS-MIB -Tpsnmpwalk -v2c -c <community> -m CPS-MIB <host> 1.3.6.1.4.1.3808Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ncps | 1.3.6.1.4.1.3808 | ||||||||||||||||||||
| !communicationLost | 1.3.6.1.4.1.3808.0.1 | ||||||||||||||||||||
| !upsOverload | 1.3.6.1.4.1.3808.0.2 | ||||||||||||||||||||
| !upsDiagnosticsFailed | 1.3.6.1.4.1.3808.0.3 | ||||||||||||||||||||
| !upsDischarged | 1.3.6.1.4.1.3808.0.4 | ||||||||||||||||||||
| !upsOnBattery | 1.3.6.1.4.1.3808.0.5 | ||||||||||||||||||||
| !upsBoostOn | 1.3.6.1.4.1.3808.0.6 | ||||||||||||||||||||
| !lowBattery | 1.3.6.1.4.1.3808.0.7 | ||||||||||||||||||||
notification SEVERE: The UPS battery capacity is low than threshold, soon to be exhausted.
| |||||||||||||||||||||
| !communicationEstablished | 1.3.6.1.4.1.3808.0.8 | ||||||||||||||||||||
| !powerRestored | 1.3.6.1.4.1.3808.0.9 | ||||||||||||||||||||
| !upsDiagnosticsPassed | 1.3.6.1.4.1.3808.0.10 | ||||||||||||||||||||
| !returnFromLowBattery | 1.3.6.1.4.1.3808.0.11 | ||||||||||||||||||||
| !upsTurnedOff | 1.3.6.1.4.1.3808.0.12 | ||||||||||||||||||||
| !upsSleeping | 1.3.6.1.4.1.3808.0.13 | ||||||||||||||||||||
notification WARNING: The UPS entered sleep mode. Output power will not be provided.
| |||||||||||||||||||||
| !upsWokeUp | 1.3.6.1.4.1.3808.0.14 | ||||||||||||||||||||
notification INFORMATION: The UPS woke up from sleep mode. Output power is being provided.
| |||||||||||||||||||||
| !upsRebootStarted | 1.3.6.1.4.1.3808.0.15 | ||||||||||||||||||||
| !upsOverTemp | 1.3.6.1.4.1.3808.0.16 | ||||||||||||||||||||
| !returnFromOverTemp | 1.3.6.1.4.1.3808.0.17 | ||||||||||||||||||||
| !upsBuckOn | 1.3.6.1.4.1.3808.0.18 | ||||||||||||||||||||
| !returnFromOverLoad | 1.3.6.1.4.1.3808.0.19 | ||||||||||||||||||||
| !returnFromDischarged | 1.3.6.1.4.1.3808.0.20 | ||||||||||||||||||||
| !upsScheduleShutdown | 1.3.6.1.4.1.3808.0.21 | ||||||||||||||||||||
| !upsEnterSleep | 1.3.6.1.4.1.3808.0.22 | ||||||||||||||||||||
| !upsChargerFailure | 1.3.6.1.4.1.3808.0.23 | ||||||||||||||||||||
| !returnFromChargerFailure | 1.3.6.1.4.1.3808.0.24 | ||||||||||||||||||||
| !upsTurnoffStarted | 1.3.6.1.4.1.3808.0.25 | ||||||||||||||||||||
| !upsTurnedOn | 1.3.6.1.4.1.3808.0.26 | ||||||||||||||||||||
| !upsRemoteCommandFailed | 1.3.6.1.4.1.3808.0.27 | ||||||||||||||||||||
| !upsLostRedundant | 1.3.6.1.4.1.3808.0.28 | ||||||||||||||||||||
| !upsSignalClientShutdown | 1.3.6.1.4.1.3808.0.29 | ||||||||||||||||||||
| !upsEmergencyPowerOff | 1.3.6.1.4.1.3808.0.30 | ||||||||||||||||||||
| !nclBankOn | 1.3.6.1.4.1.3808.0.31 | ||||||||||||||||||||
| !nclBankOff | 1.3.6.1.4.1.3808.0.32 | ||||||||||||||||||||
| !upsCommandCancel | 1.3.6.1.4.1.3808.0.33 | ||||||||||||||||||||
| !upsStartBatteryTest | 1.3.6.1.4.1.3808.0.34 | ||||||||||||||||||||
| !upsRemainRuntimeLowThanThreshold | 1.3.6.1.4.1.3808.0.35 | ||||||||||||||||||||
| !nclBankStartScheduleOff | 1.3.6.1.4.1.3808.0.36 | ||||||||||||||||||||
notification INFORMATION: Non-Critial bank has started its schedule off sequence.
| |||||||||||||||||||||
| !upsEstimationAbort | 1.3.6.1.4.1.3808.0.37 | ||||||||||||||||||||
| !upsHardwareFault | 1.3.6.1.4.1.3808.0.38 | ||||||||||||||||||||
| !upsBatteryNotPresent | 1.3.6.1.4.1.3808.0.39 | ||||||||||||||||||||
| !upsWiringFault | 1.3.6.1.4.1.3808.0.40 | ||||||||||||||||||||
| !upsWiringFaultCleared | 1.3.6.1.4.1.3808.0.41 | ||||||||||||||||||||
| !upsEnterBypassMode | 1.3.6.1.4.1.3808.0.42 | ||||||||||||||||||||
| !upsReturnFromBypassMode | 1.3.6.1.4.1.3808.0.43 | ||||||||||||||||||||
| !upsBypassOverload | 1.3.6.1.4.1.3808.0.44 | ||||||||||||||||||||
| !upsBypassOverloadCleared | 1.3.6.1.4.1.3808.0.45 | ||||||||||||||||||||
| !upsEnterECOMode | 1.3.6.1.4.1.3808.0.46 | ||||||||||||||||||||
| !upsReturnFromECOMode | 1.3.6.1.4.1.3808.0.47 | ||||||||||||||||||||
| !upsBatteryOverThreeYear | 1.3.6.1.4.1.3808.0.48 | ||||||||||||||||||||
| !upsBatteryExpiration | 1.3.6.1.4.1.3808.0.49 | ||||||||||||||||||||
| !upsBatteryReplacement | 1.3.6.1.4.1.3808.0.50 | ||||||||||||||||||||
| !upsModuleInvertorAlarm | 1.3.6.1.4.1.3808.0.51 | ||||||||||||||||||||
| !upsModuleRectifierAlarm | 1.3.6.1.4.1.3808.0.52 | ||||||||||||||||||||
| !upsModuleFanAlarm | 1.3.6.1.4.1.3808.0.53 | ||||||||||||||||||||
| !upsModuleManualShutdown | 1.3.6.1.4.1.3808.0.54 | ||||||||||||||||||||
| !upsModuleOverload | 1.3.6.1.4.1.3808.0.55 | ||||||||||||||||||||
| !upsFirmwareUpgradeStart | 1.3.6.1.4.1.3808.0.56 | ||||||||||||||||||||
| !upsFirmwareUpgradeEnd | 1.3.6.1.4.1.3808.0.57 | ||||||||||||||||||||
| !upsRFC1628TrapOnBattery | 1.3.6.1.4.1.3808.0.58 | ||||||||||||||||||||
| !upsRFC1628TrapTestCompleted | 1.3.6.1.4.1.3808.0.59 | ||||||||||||||||||||
| !upsRFC1628TrapAlarmEntryAdded | 1.3.6.1.4.1.3808.0.60 | ||||||||||||||||||||
| !failAuthViaHTTP | 1.3.6.1.4.1.3808.0.61 | ||||||||||||||||||||
| !passwordChange | 1.3.6.1.4.1.3808.0.62 | ||||||||||||||||||||
| !failAuthViaConsole | 1.3.6.1.4.1.3808.0.63 | ||||||||||||||||||||
| !configFileUpload | 1.3.6.1.4.1.3808.0.64 | ||||||||||||||||||||
| !adminLoginInfo | 1.3.6.1.4.1.3808.0.65 | ||||||||||||||||||||
| !adminLogoutInfo | 1.3.6.1.4.1.3808.0.66 | ||||||||||||||||||||
| !deviceLoginInfo | 1.3.6.1.4.1.3808.0.67 | ||||||||||||||||||||
| !deviceLogoutInfo | 1.3.6.1.4.1.3808.0.68 | ||||||||||||||||||||
| !configurationChanged | 1.3.6.1.4.1.3808.0.69 | ||||||||||||||||||||
| !clientRegistered | 1.3.6.1.4.1.3808.0.70 | ||||||||||||||||||||
| !clientRemoved | 1.3.6.1.4.1.3808.0.71 | ||||||||||||||||||||
| !testEvent | 1.3.6.1.4.1.3808.0.72 | ||||||||||||||||||||
| !outletUserLoginInfo | 1.3.6.1.4.1.3808.0.73 | ||||||||||||||||||||
| !outletUserLogoutInfo | 1.3.6.1.4.1.3808.0.74 | ||||||||||||||||||||
| !firmwareUpdateSuccess | 1.3.6.1.4.1.3808.0.75 | ||||||||||||||||||||
| !firmwareUpdateFail | 1.3.6.1.4.1.3808.0.76 | ||||||||||||||||||||
| !ePDUCommunicationEstablished | 1.3.6.1.4.1.3808.0.100 | ||||||||||||||||||||
notification INFORMATIONAL: Communication with a Rack PDU has been established. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUCommunicationLost | 1.3.6.1.4.1.3808.0.101 | ||||||||||||||||||||
notification SEVERE: Communication with a Rack PDU has been lost. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUOutletOn | 1.3.6.1.4.1.3808.0.102 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on a Switched Rack PDU has turned on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUOutletOff | 1.3.6.1.4.1.3808.0.103 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on a Switched Rack PDU has turned off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUDeviceConfigChange | 1.3.6.1.4.1.3808.0.104 | ||||||||||||||||||||
notification INFORMATIONAL: A device configuration change has been made on a Rack PDU. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUOutletConfigChange | 1.3.6.1.4.1.3808.0.105 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet configuration change has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDULowLoad | 1.3.6.1.4.1.3808.0.106 | ||||||||||||||||||||
notification WARNING: A Rack PDU has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDULowLoadCleared | 1.3.6.1.4.1.3808.0.107 | ||||||||||||||||||||
notification INFORMATIONAL: The low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDUNearOverload | 1.3.6.1.4.1.3808.0.108 | ||||||||||||||||||||
notification WARNING: A Rack PDU is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDUNearOverloadCleared | 1.3.6.1.4.1.3808.0.109 | ||||||||||||||||||||
notification INFORMATIONAL: The near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDUOverload | 1.3.6.1.4.1.3808.0.110 | ||||||||||||||||||||
notification SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDUOverloadCleared | 1.3.6.1.4.1.3808.0.111 | ||||||||||||||||||||
notification INFORMATIONAL: The overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDUDelayOutletOnCommand | 1.3.6.1.4.1.3808.0.112 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to turn on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUDelayOutletOffCommand | 1.3.6.1.4.1.3808.0.113 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to turn off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUDelayOutletRebootCommand | 1.3.6.1.4.1.3808.0.114 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on a Switched Rack PDU has been assigned to reboot. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUCancelPendingCommand | 1.3.6.1.4.1.3808.0.115 | ||||||||||||||||||||
notification INFORMATIONAL: A cancel pending command has been made on a Switched Rack PDU. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number (0 indicates all outlets). The fourth argument is the outlet name (or device name if all outlets). | |||||||||||||||||||||
| !ePDULineUndervoltage | 1.3.6.1.4.1.3808.0.116 | ||||||||||||||||||||
notification SEVERE: Utility Line Undervoltage The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDULineUndervoltageCleared | 1.3.6.1.4.1.3808.0.117 | ||||||||||||||||||||
notification INFORMATIONAL: Utility Line Undervoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDULineOvervoltage | 1.3.6.1.4.1.3808.0.118 | ||||||||||||||||||||
notification SEVERE: Utility Line Overvoltage. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDULineOvervoltageCleared | 1.3.6.1.4.1.3808.0.119 | ||||||||||||||||||||
notification INFORMATIONAL: Utility Line Overvoltage Cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase number. | |||||||||||||||||||||
| !ePDUPowerSupply1Fail | 1.3.6.1.4.1.3808.0.120 | ||||||||||||||||||||
notification SEVERE: Power Supply 1 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUPowerSupply1Ok | 1.3.6.1.4.1.3808.0.121 | ||||||||||||||||||||
notification INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUPowerSupply2Fail | 1.3.6.1.4.1.3808.0.122 | ||||||||||||||||||||
notification SEVERE: Power Supply 2 on Rack PDU is in FAIL state. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUPowerSupply2Ok | 1.3.6.1.4.1.3808.0.123 | ||||||||||||||||||||
notification INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUBankLowLoad | 1.3.6.1.4.1.3808.0.124 | ||||||||||||||||||||
notification WARNING: A Rack PDU bank has violated the low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the bank number. | |||||||||||||||||||||
| !ePDUBankLowLoadCleared | 1.3.6.1.4.1.3808.0.125 | ||||||||||||||||||||
notification INFORMATIONAL: The low load condition on a Rack PDU bank has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number. | |||||||||||||||||||||
| !ePDUBankNearOverload | 1.3.6.1.4.1.3808.0.126 | ||||||||||||||||||||
notification WARNING: A Rack PDU bank is near an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the bank number. | |||||||||||||||||||||
| !ePDUBankNearOverloadCleared | 1.3.6.1.4.1.3808.0.127 | ||||||||||||||||||||
notification INFORMATIONAL: The near overload condition on a Rack PDU bank has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase/bank number. | |||||||||||||||||||||
| !ePDUBankOverload | 1.3.6.1.4.1.3808.0.128 | ||||||||||||||||||||
notification SEVERE: A Rack PDU bank is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the bank number. | |||||||||||||||||||||
| !ePDUBankOverloadCleared | 1.3.6.1.4.1.3808.0.129 | ||||||||||||||||||||
notification INFORMATIONAL: The overload condition on a Rack PDU bank has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank number. | |||||||||||||||||||||
| !ePDUComponentCommunicationEstablished | 1.3.6.1.4.1.3808.0.130 | ||||||||||||||||||||
notification INFORMATIONAL: Component communication lost has been cleared. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUComponentCommunicationLost | 1.3.6.1.4.1.3808.0.131 | ||||||||||||||||||||
notification SEVERE: Component communication lost. The first argument is the serial number. The second argument is the device name. | |||||||||||||||||||||
| !ePDUOutletLowLoad | 1.3.6.1.4.1.3808.0.132 | ||||||||||||||||||||
notification WARNING: A Rack PDU has violated the outlet low load threshold. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUOutletLowLoadCleared | 1.3.6.1.4.1.3808.0.133 | ||||||||||||||||||||
notification INFORMATIONAL: The outlet low load condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUOutletNearOverload | 1.3.6.1.4.1.3808.0.134 | ||||||||||||||||||||
notification WARNING: A Rack PDU is near an outlet overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUOutletNearOverloadCleared | 1.3.6.1.4.1.3808.0.135 | ||||||||||||||||||||
notification INFORMATIONAL: The outlet near overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUOutletOverload | 1.3.6.1.4.1.3808.0.136 | ||||||||||||||||||||
notification SEVERE: A Rack PDU is in an overload condition. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !ePDUOutletOverloadCleared | 1.3.6.1.4.1.3808.0.137 | ||||||||||||||||||||
notification INFORMATIONAL: The outlet overload condition on a Rack PDU has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !envHighTemperatureViolation | 1.3.6.1.4.1.3808.0.200 | ||||||||||||||||||||
notification WARNING: The environment high temperature threshold has been violated. | |||||||||||||||||||||
| !envHighTemperatureBack | 1.3.6.1.4.1.3808.0.201 | ||||||||||||||||||||
notification INFORMATION: The environment temperature returned from high value. | |||||||||||||||||||||
| !envLowTemperatureViolation | 1.3.6.1.4.1.3808.0.202 | ||||||||||||||||||||
notification WARNING: The environment low temperature threshold has been violated. | |||||||||||||||||||||
| !envLowTempBack | 1.3.6.1.4.1.3808.0.203 | ||||||||||||||||||||
notification INFORMATION: The environment temperature returned from low value. | |||||||||||||||||||||
| !envHighHumidityViolation | 1.3.6.1.4.1.3808.0.204 | ||||||||||||||||||||
notification WARNING: The environment high humidity threshold has been violated. | |||||||||||||||||||||
| !envHighHumidityBack | 1.3.6.1.4.1.3808.0.205 | ||||||||||||||||||||
notification INFORMATION: The environment humidity return from high value. | |||||||||||||||||||||
| !envLowHumidityViolation | 1.3.6.1.4.1.3808.0.206 | ||||||||||||||||||||
notification WARNING: The environment low humidity threshold has been violated. | |||||||||||||||||||||
| !envLowHumdBack | 1.3.6.1.4.1.3808.0.207 | ||||||||||||||||||||
notification INFORMATION: The environment humidity return from low value. | |||||||||||||||||||||
| !envDryContactAbnormal | 1.3.6.1.4.1.3808.0.208 | ||||||||||||||||||||
notification INFORMATION: The Contact is abnormal. | |||||||||||||||||||||
| !envDryContactNormal | 1.3.6.1.4.1.3808.0.209 | ||||||||||||||||||||
notification INFORMATION: The Contact has returned from abnormal. | |||||||||||||||||||||
| !envConntected | 1.3.6.1.4.1.3808.0.210 | ||||||||||||||||||||
notification INFORMATION: The Environment Sensor has been connected.
| |||||||||||||||||||||
| !envDisconntected | 1.3.6.1.4.1.3808.0.211 | ||||||||||||||||||||
notification INFORMATION: The Environment Sensor has been disconnected.
| |||||||||||||||||||||
| !envRateOfTemperatureChangeAbnormal | 1.3.6.1.4.1.3808.0.212 | ||||||||||||||||||||
notification INFORMATION: The rate of temperature change is abnormal. | |||||||||||||||||||||
| !envRateOfHumdChangeAbnormal | 1.3.6.1.4.1.3808.0.213 | ||||||||||||||||||||
notification INFORMATION: The rate of humidity change is abnormal. | |||||||||||||||||||||
| !accessoryDeviceEvent | 1.3.6.1.4.1.3808.0.250 | ||||||||||||||||||||
| !accessoryDeviceAlarm | 1.3.6.1.4.1.3808.0.251 | ||||||||||||||||||||
| !accessoryDeviceAlarmClear | 1.3.6.1.4.1.3808.0.252 | ||||||||||||||||||||
| !envTemperatureEvent | 1.3.6.1.4.1.3808.0.253 | ||||||||||||||||||||
notification INFORMATIONAL: An environment sensor Temperature event has been happened. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the temperture table index. The fifth argument is the temperture. | |||||||||||||||||||||
| !envTemperatureAlarm | 1.3.6.1.4.1.3808.0.254 | ||||||||||||||||||||
notification Alarm: An environment sensor Temperature alarm has been detected. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the temperture table index. The fifth argument is the temperture. | |||||||||||||||||||||
| !envTemperatureAlarmClear | 1.3.6.1.4.1.3808.0.255 | ||||||||||||||||||||
notification INFORMATIONAL: An environment sensor Temperature alarm has been cleared. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the temperture table index. The fifth argument is the temperture. | |||||||||||||||||||||
| !envHumidityEvent | 1.3.6.1.4.1.3808.0.256 | ||||||||||||||||||||
notification INFORMATIONAL: An environment sensor Humidity event has been happened. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the humidity table index. The fifth argument is the humidity. | |||||||||||||||||||||
| !envHumidityAlarm | 1.3.6.1.4.1.3808.0.257 | ||||||||||||||||||||
notification Alarm: An environment sensor Humidity alarm has been detected. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the humidity table index. The fifth argument is the humidity. | |||||||||||||||||||||
| !envHumidityAlarmClear | 1.3.6.1.4.1.3808.0.258 | ||||||||||||||||||||
notification INFORMATIONAL: An environment sensor Humidity alarm has been cleared. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the humidity table index. The fifth argument is the humidity. | |||||||||||||||||||||
| !envContactEvent | 1.3.6.1.4.1.3808.0.259 | ||||||||||||||||||||
notification INFORMATIONAL: An environment sensor Contact event has been happened. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the contect table index. The fifth argument is the contact name. | |||||||||||||||||||||
| !envContactAlarm | 1.3.6.1.4.1.3808.0.260 | ||||||||||||||||||||
notification Alarm: An environment sensor Contact alarm has been detected. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the contect table index. The fifth argument is the contact name. | |||||||||||||||||||||
| !envContactAlarmClear | 1.3.6.1.4.1.3808.0.261 | ||||||||||||||||||||
notification INFORMATIONAL: An environment sensor Contact alarm has been cleared. The first argument is the sensor serial number. The second argument is the sensor name. The third argument is the sensor location. The foutrh argument is the contect table index. The fifth argument is the contact name. | |||||||||||||||||||||
| !atsSwitchSource | 1.3.6.1.4.1.3808.0.301 | ||||||||||||||||||||
notification INFORMATIONAL: ATS has switched source. The first argument is the device name. The second argument is the serial number. The third argument is the selected source. | |||||||||||||||||||||
| !atsSourceFault | 1.3.6.1.4.1.3808.0.302 | ||||||||||||||||||||
notification WARNING: Source fault occurs. The first argument is the device name. The second argument is the serial number. The third argument is the source name. | |||||||||||||||||||||
| !atsSourceFaultCleared | 1.3.6.1.4.1.3808.0.303 | ||||||||||||||||||||
notification INFORMATIONAL: Source fault has been cleared. The first argument is the device name. The second argument is the serial number. The third argument is the source name. | |||||||||||||||||||||
| !atsRedundancyFail | 1.3.6.1.4.1.3808.0.304 | ||||||||||||||||||||
notification WARNING: Redundancy fails. The first argument is the device name. The second argument is the serial number. The third argument is the source name. | |||||||||||||||||||||
| !atsRedundancyRestored | 1.3.6.1.4.1.3808.0.305 | ||||||||||||||||||||
notification INFORMATIONAL: Redundancy has been restored. The first argument is the device name. The second argument is the serial number. The third argument is the source name. | |||||||||||||||||||||
| !atsInputHighVoltage | 1.3.6.1.4.1.3808.0.306 | ||||||||||||||||||||
notification WARNING: The upper voltage limit has been crossed. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the phase voltage. | |||||||||||||||||||||
| !atsInputHighVoltageCleared | 1.3.6.1.4.1.3808.0.307 | ||||||||||||||||||||
notification INFORMATIONAL: The upper voltage condition has been cleared. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the phase voltage. | |||||||||||||||||||||
| !atsInputLowVoltage | 1.3.6.1.4.1.3808.0.308 | ||||||||||||||||||||
notification WARNING: The lower voltage limit has been crossed. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the phase voltage. | |||||||||||||||||||||
| !atsInputLowVoltageCleared | 1.3.6.1.4.1.3808.0.309 | ||||||||||||||||||||
notification INFORMATIONAL: The lower voltage condition has been cleared. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the phase voltage. | |||||||||||||||||||||
| !atsInputHighFrequency | 1.3.6.1.4.1.3808.0.310 | ||||||||||||||||||||
notification WARNING: The upper frequency limit has been crossed. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the input frequency. | |||||||||||||||||||||
| !atsInputHighFrequencyCleared | 1.3.6.1.4.1.3808.0.311 | ||||||||||||||||||||
notification INFORMATIONAL: The upper frequency condition has been cleared. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the input frequency. | |||||||||||||||||||||
| !atsInputLowFrequency | 1.3.6.1.4.1.3808.0.312 | ||||||||||||||||||||
notification WARNING: The lower frequency limit has been crossed. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the input frequency. | |||||||||||||||||||||
| !atsInputLowFrequencyCleared | 1.3.6.1.4.1.3808.0.313 | ||||||||||||||||||||
notification INFORMATIONAL: The lower frequency condition has been cleared. The first argument is the device name. The second argument is the serial number. The third argument is the source name. The fourth argument is the input frequency. | |||||||||||||||||||||
| !atsCommunicationLost | 1.3.6.1.4.1.3808.0.314 | ||||||||||||||||||||
notification MAJOR: ATS communication lost. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsCommunicationEstablished | 1.3.6.1.4.1.3808.0.315 | ||||||||||||||||||||
notification INFORMATIONAL: ATS communication has been established. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsLCDCommunicationLost | 1.3.6.1.4.1.3808.0.316 | ||||||||||||||||||||
notification WARNING: LCD communication lost. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsLCDCommunicationLostCleared | 1.3.6.1.4.1.3808.0.317 | ||||||||||||||||||||
notification INFORMATIONAL: LCD communication lost has been cleared. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsDB9CommunicationLost | 1.3.6.1.4.1.3808.0.318 | ||||||||||||||||||||
notification WARNING: DB9 communication lost. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsDB9CommunicationLostCleared | 1.3.6.1.4.1.3808.0.319 | ||||||||||||||||||||
notification INFORMATIONAL: DB9 communication lost has been cleared. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsPowerSupplyFault | 1.3.6.1.4.1.3808.0.320 | ||||||||||||||||||||
notification CRITICAL: Power supply failure. The first argument is the device name. The second argument is the serial number. The third argument is the input source of the power supply. | |||||||||||||||||||||
| !atsPowerSupplyFaultCleared | 1.3.6.1.4.1.3808.0.321 | ||||||||||||||||||||
notification CRITICAL: Power supply failure. The first argument is the device name. The second argument is the serial number. The third argument is the input source of the power supply. | |||||||||||||||||||||
| !atsDevHardwareFault | 1.3.6.1.4.1.3808.0.322 | ||||||||||||||||||||
notification CRITICAL: Device hardware failure. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsDevHardwareFaultCleared | 1.3.6.1.4.1.3808.0.323 | ||||||||||||||||||||
notification INFORMATIONAL: Device hardware failure has been cleared. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsSourceConfigChanged | 1.3.6.1.4.1.3808.0.324 | ||||||||||||||||||||
notification INFORMATIONAL: A source configuration change has been made. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsDeviceConfigChanged | 1.3.6.1.4.1.3808.0.325 | ||||||||||||||||||||
notification INFORMATIONAL: A device configuration change has been made. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsOutletConfigChanged | 1.3.6.1.4.1.3808.0.326 | ||||||||||||||||||||
notification INFORMATIONAL: A outlet configuration change has been made. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsEventCountsCleared | 1.3.6.1.4.1.3808.0.327 | ||||||||||||||||||||
notification INFORMATIONAL: Event counts has been cleared. The first argument is the device name. The second argument is the serial number. | |||||||||||||||||||||
| !atsOverload | 1.3.6.1.4.1.3808.0.328 | ||||||||||||||||||||
notification WARNING: The load has exceeded overload threshold. The first argument is the device name. The second argument is the serial number. The third argument is the bank number. The third argument is the load. | |||||||||||||||||||||
| !atsOverloadCleared | 1.3.6.1.4.1.3808.0.329 | ||||||||||||||||||||
notification INFORMATIONAL: The overload condition has been cleared. The first argument is the device name. The second argument is the serial number. The third argument is the bank number. The third argument is the load. | |||||||||||||||||||||
| !atsNearOverload | 1.3.6.1.4.1.3808.0.330 | ||||||||||||||||||||
notification WARNING: The load has exceeded near overload threshold. The first argument is the device name. The second argument is the serial number. The third argument is the bank number. The third argument is the load. | |||||||||||||||||||||
| !atsNearOverloadCleared | 1.3.6.1.4.1.3808.0.331 | ||||||||||||||||||||
notification INFORMATIONAL: The near overload condition has beed cleared. The first argument is the device name. The second argument is the serial number. The third argument is the bank number. The third argument is the load. | |||||||||||||||||||||
| !atsLowLoad | 1.3.6.1.4.1.3808.0.332 | ||||||||||||||||||||
notification WARNING: The load has been lower than low load threshold. The first argument is the device name. The second argument is the serial number. The third argument is the bank number. The third argument is the load. | |||||||||||||||||||||
| !atsLowLoadCleared | 1.3.6.1.4.1.3808.0.333 | ||||||||||||||||||||
notification INFORMATIONAL: The low load condition has been cleared. The first argument is the device name. The second argument is the serial number. The third argument is the bank number. The third argument is the load. | |||||||||||||||||||||
| !atsOutletOnCommand | 1.3.6.1.4.1.3808.0.334 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on ATS has been assigned to turn on. The first argument is the device name. The second argument is the serial number. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !atsOutletOffCommand | 1.3.6.1.4.1.3808.0.335 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on ATS has been assigned to turn off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !atsOutletRebootCommand | 1.3.6.1.4.1.3808.0.336 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on ATS has been assigned to reboot. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !atsCancelPendingCommand | 1.3.6.1.4.1.3808.0.337 | ||||||||||||||||||||
notification INFORMATIONAL: A cancel pending command has been made on ATS. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number (0 indicates all outlets). The fourth argument is the outlet name (or device name if all outlets). | |||||||||||||||||||||
| !atsOutletOn | 1.3.6.1.4.1.3808.0.338 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on ATS has turned on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !atsOutletOff | 1.3.6.1.4.1.3808.0.339 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet on ATS has turned off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !pduDeviceEvent | 1.3.6.1.4.1.3808.0.400 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU device event has been happened. The first argument is the serial number. The second argument is the device name. The third argument is the device table index. | |||||||||||||||||||||
| !pduDeviceAlarm | 1.3.6.1.4.1.3808.0.401 | ||||||||||||||||||||
notification Alarm: A PDU device alarm has been detected. The first argument is the serial number. The second argument is the device name. The third argument is the device table index. | |||||||||||||||||||||
| !pduDeviceAlarmClear | 1.3.6.1.4.1.3808.0.402 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU device alarm has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the device table index. | |||||||||||||||||||||
| !pduPhaseEvent | 1.3.6.1.4.1.3808.0.403 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU phase event has been happened. The first argument is the serial number. The second argument is the device name. The third argument is the phase table index. The foutrh argument is the phase number. | |||||||||||||||||||||
| !pduPhaseAlarm | 1.3.6.1.4.1.3808.0.404 | ||||||||||||||||||||
notification Alarm: A PDU phase alarm has been detected. The first argument is the serial number. The second argument is the device name. The third argument is the phase table index. The foutrh argument is the phase number. | |||||||||||||||||||||
| !pduPhaseAlarmClear | 1.3.6.1.4.1.3808.0.405 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU phase alarm has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the phase table index. The foutrh argument is the phase number. | |||||||||||||||||||||
| !pduBankEvent | 1.3.6.1.4.1.3808.0.406 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU bank event has been happened. The first argument is the serial number. The second argument is the device name. The third argument is the bank table index. The foutrh argument is the bank number. | |||||||||||||||||||||
| !pduBankAlarm | 1.3.6.1.4.1.3808.0.407 | ||||||||||||||||||||
notification Alarm: A PDU bank alarm has been detected. The first argument is the serial number. The second argument is the device name. The third argument is the bank table index. The foutrh argument is the bank number. | |||||||||||||||||||||
| !pduBankAlarmClear | 1.3.6.1.4.1.3808.0.408 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU bank alarm has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the bank table index. The foutrh argument is the bank number. | |||||||||||||||||||||
| !pduOutletSwitchedEvent | 1.3.6.1.4.1.3808.0.409 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU switched outlet event has been happened. The first argument is the serial number. The second argument is the device name. The third argument is the outlet table index. The foutrh argument is the outlet number. The fifth argument is the outlet name. | |||||||||||||||||||||
| !pduOutletSwitchedAlarm | 1.3.6.1.4.1.3808.0.410 | ||||||||||||||||||||
notification Alarm: A PDU switched outlet alarm has been detected. The first argument is the serial number. The second argument is the device name. The third argument is the outlet table index. The foutrh argument is the outlet number. The fifth argument is the outlet name. | |||||||||||||||||||||
| !pduOutletSwitchedAlarmClear | 1.3.6.1.4.1.3808.0.411 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU switched outlet alarm has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet table index. The foutrh argument is the outlet number. The fifth argument is the outlet name. | |||||||||||||||||||||
| !pduOutletMeteredEvent | 1.3.6.1.4.1.3808.0.412 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU metered outlet event has been happened. The first argument is the serial number. The second argument is the device name. The third argument is the outlet table index. The foutrh argument is the outlet number. The fifth argument is the outlet name. | |||||||||||||||||||||
| !pduOutletMeteredAlarm | 1.3.6.1.4.1.3808.0.413 | ||||||||||||||||||||
notification Alarm: A PDU metered outlet alarm has been detected. The first argument is the serial number. The second argument is the device name. The third argument is the outlet table index. The foutrh argument is the outlet number. The fifth argument is the outlet name. | |||||||||||||||||||||
| !pduOutletMeteredAlarmClear | 1.3.6.1.4.1.3808.0.414 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU metered outlet alarm has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the outlet table index. The foutrh argument is the outlet number. The fifth argument is the outlet name. | |||||||||||||||||||||
| !pduDaisyChainEvent | 1.3.6.1.4.1.3808.0.415 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU daisy-chain event has been happened. The first argument is the host serial number. The second argument is the host device name. The third argument is the event device table index. The foutrh argument is the event device serial number. The fifth argument is the event device name. | |||||||||||||||||||||
| !pduDaisyChainAlarm | 1.3.6.1.4.1.3808.0.416 | ||||||||||||||||||||
notification Alarm: A PDU daisy-chain alarm has been detected. The first argument is the host serial number. The second argument is the host device name. The third argument is the alarm device table index. The foutrh argument is the alarm device serial number. The fifth argument is the alarm device name. | |||||||||||||||||||||
| !pduDaisyChainAlarmClear | 1.3.6.1.4.1.3808.0.417 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU daisy-chain alarm has been cleared. The first argument is the host serial number. The second argument is the host device name. The third argument is the alarm device table index. The foutrh argument is the alarm deice serial number. The fifth argument is the alarm device name. | |||||||||||||||||||||
| !pduOutletMonitoredEvent | 1.3.6.1.4.1.3808.0.418 | ||||||||||||||||||||
notification INFORMATIONAL: A PDU metered outlet event has been happened. The first argument is the serial number. The second argument is the device name. The third argument is the outlet table index. The foutrh argument is the outlet number. The fifth argument is the outlet name. | |||||||||||||||||||||
| !pduSourceEvent | 1.3.6.1.4.1.3808.0.419 | ||||||||||||||||||||
notification INFORMATIONAL: A ATS source event has been happened. The first argument is the serial number. The second argument is the device name. The third argument is the source table index. | |||||||||||||||||||||
| !pduSourceAlarm | 1.3.6.1.4.1.3808.0.420 | ||||||||||||||||||||
notification INFORMATIONAL: A ATS source alarm has been detected. The first argument is the serial number. The second argument is the device name. The third argument is the source table index. | |||||||||||||||||||||
| !pduSourceAlarmClear | 1.3.6.1.4.1.3808.0.421 | ||||||||||||||||||||
notification INFORMATIONAL: A ATS source alarm has been cleared. The first argument is the serial number. The second argument is the device name. The third argument is the source table index. | |||||||||||||||||||||
| !upsOutletOn | 1.3.6.1.4.1.3808.0.500 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet has turned on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !upsOutletOff | 1.3.6.1.4.1.3808.0.501 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet has turned off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !upsOutletOnCommand | 1.3.6.1.4.1.3808.0.502 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet has been assigned to turn on. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !upsOutletOffCommand | 1.3.6.1.4.1.3808.0.503 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet has been assigned to turn off. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !upsOutletRebootCommand | 1.3.6.1.4.1.3808.0.504 | ||||||||||||||||||||
notification INFORMATIONAL: An outlet has been assigned to reboot. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !upsCancelPendingCommand | 1.3.6.1.4.1.3808.0.505 | ||||||||||||||||||||
notification INFORMATIONAL: A cancel pending command has been made on an outlet. The first argument is the serial number. The second argument is the device name. The third argument is the outlet index number. The fourth argument is the outlet name. | |||||||||||||||||||||
| !upsAutoPingFail | 1.3.6.1.4.1.3808.0.506 | ||||||||||||||||||||
notification SEVERE: AutoPing failed. | |||||||||||||||||||||
| !upsAutoPingRecovery | 1.3.6.1.4.1.3808.0.507 | ||||||||||||||||||||
notification INFORMATIONAL: AutoPing recovered. | |||||||||||||||||||||
| !bmSystemAlarm | 1.3.6.1.4.1.3808.0.600 | ||||||||||||||||||||
notification ALARM: System alarm occurance. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the alarm event specific identifier. The fifth argument is the trap information string. | |||||||||||||||||||||
| !bmSystemWarning | 1.3.6.1.4.1.3808.0.601 | ||||||||||||||||||||
notification WARNING: System warning occurance. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the alarm event specific identifier. The fifth argument is the trap information string. | |||||||||||||||||||||
| !bmSystemInfo | 1.3.6.1.4.1.3808.0.602 | ||||||||||||||||||||
notification INFO: System information. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the alarm event specific identifier. The fifth argument is the trap information string. | |||||||||||||||||||||
| !bmProbesAlarm | 1.3.6.1.4.1.3808.0.603 | ||||||||||||||||||||
notification ALARM: Probe alarm event. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the string index the probe located. The fifth argument is the battery index the probe located. The sixth argument is the alarm event specific identifier. The seventh argument is the trap information string. | |||||||||||||||||||||
| !bmSProbesWarning | 1.3.6.1.4.1.3808.0.604 | ||||||||||||||||||||
notification WARNING: Probe warning event. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the string index the probe located. The fifth argument is the battery index the probe located. The sixth argument is the alarm event specific identifier. The seventh argument is the trap information string. | |||||||||||||||||||||
| !bmProbesInfo | 1.3.6.1.4.1.3808.0.605 | ||||||||||||||||||||
notification INFO: Probe information. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the string index the probe located. The fifth argument is the battery index the probe located. The sixth argument is the alarm event specific identifier. The seventh argument is the trap information string. | |||||||||||||||||||||
| !bmStringsAlarm | 1.3.6.1.4.1.3808.0.606 | ||||||||||||||||||||
notification ALARM: String alarm event. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the string index. The fifth argument is the alarm event specific identifier. The sixth argument is the trap information string. | |||||||||||||||||||||
| !bmStringsWarning | 1.3.6.1.4.1.3808.0.607 | ||||||||||||||||||||
notification WARNING: String warning event. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the string index. The fifth argument is the alarm event specific identifier. The sixth argument is the trap information string. | |||||||||||||||||||||
| !bmStringsInfo | 1.3.6.1.4.1.3808.0.608 | ||||||||||||||||||||
notification INFO: String info event. The first argument is the bm device serial number. The second argument is the bm system identification name. The third argument is the bm system location. The fourth argument is the string index. The fifth argument is the alarm event specific identifier. The sixth argument is the trap information string. | |||||||||||||||||||||
| !currProbesAlarm | 1.3.6.1.4.1.3808.0.700 | ||||||||||||||||||||
notification ALARM: Current probe alarm event. The first argument is the system identification name. The second argument is the system location. The third argument is the alarm event specific identifier. The fourth argument is the trap information string. | |||||||||||||||||||||
| !currProbesWarning | 1.3.6.1.4.1.3808.0.701 | ||||||||||||||||||||
notification Warning: Current probe warning event. The first argument is the system identification name. The second argument is the system location. The third argument is the alarm event specific identifier. The fourth argument is the trap information string. | |||||||||||||||||||||
| !currProbesInfo | 1.3.6.1.4.1.3808.0.702 | ||||||||||||||||||||
notification Info: Current probe info event. The first argument is the system identification name. The second argument is the system location. The third argument is the alarm event specific identifier. The fourth argument is the trap information string. | |||||||||||||||||||||
| Nproducts | 1.3.6.1.4.1.3808.1 | ||||||||||||||||||||
| Nhardware | 1.3.6.1.4.1.3808.1.1 | ||||||||||||||||||||
| Nups | 1.3.6.1.4.1.3808.1.1.1 | ||||||||||||||||||||
| NupsIdent | 1.3.6.1.4.1.3808.1.1.1.1 | ||||||||||||||||||||
| NupsBaseIdent | 1.3.6.1.4.1.3808.1.1.1.1.1 | ||||||||||||||||||||
| SupsBaseIdentModel | 1.3.6.1.4.1.3808.1.1.1.1.1.1 | DisplayString | RO | mandatory | OL2200RTXL2U | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The UPS model name. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsBaseIdentName | 1.3.6.1.4.1.3808.1.1.1.1.1.2 | DisplayString | RW | mandatory | example.com | ||||||||||||||||
scalar · DisplayString · read-write · mandatory The UPS identified name could be set by the administrator. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsAdvanceIdent | 1.3.6.1.4.1.3808.1.1.1.1.2 | ||||||||||||||||||||
| SupsAdvanceIdentFirmwareRevision | 1.3.6.1.4.1.3808.1.1.1.1.2.1 | DisplayString | RO | mandatory | S1A17 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The UPS firmware revision. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceIdentDateOfManufacture | 1.3.6.1.4.1.3808.1.1.1.1.2.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The UPS manufacture date in mm/dd/yy format. | |||||||||||||||||||||
| SupsAdvanceIdentSerialNumber | 1.3.6.1.4.1.3808.1.1.1.1.2.3 | DisplayString | RO | mandatory | ABCFT1000001 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The UPS serial number in the internal microprocessor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceIdentAgentFirmwareRevision | 1.3.6.1.4.1.3808.1.1.1.1.2.4 | DisplayString | RO | mandatory | 1.6.0 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The SNMP agent firmware revision. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceIdentLCDFirmwareVersion | 1.3.6.1.4.1.3808.1.1.1.1.2.5 | DisplayString | RO | mandatory | | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The revision number of the UPS LCD firmware. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceIdentPowerRating | 1.3.6.1.4.1.3808.1.1.1.1.2.6 | INTEGER | RO | mandatory | 2200 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The Volt-Amp rating of the UPS. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceIdentLoadPower | 1.3.6.1.4.1.3808.1.1.1.1.2.7 | INTEGER | RO | mandatory | 2200 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The power rating(Watts) of the UPS. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceIdentCurrentRating | 1.3.6.1.4.1.3808.1.1.1.1.2.8 | INTEGER | RO | mandatory | 183 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The output current rating of the UPS. Measured in tenths of Amps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceIdentAgentSerialNumber | 1.3.6.1.4.1.3808.1.1.1.1.2.9 | DisplayString | RO | mandatory | TALNS2003137 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifying the serial number of the Agent. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsBattery | 1.3.6.1.4.1.3808.1.1.1.2 | ||||||||||||||||||||
| NupsBaseBattery | 1.3.6.1.4.1.3808.1.1.1.2.1 | ||||||||||||||||||||
| SupsBaseBatteryStatus | 1.3.6.1.4.1.3808.1.1.1.2.1.1 | INTEGER | RO | mandatory | batteryNormal(2) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The UPS battery status. A batteryLow(3) value means the battery will be exhausted soon under the current load. The amount of low battery run time can be configured by the upsAdvanceConfigLowBatteryRunTime.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsBaseBatteryTimeOnBattery | 1.3.6.1.4.1.3808.1.1.1.2.1.2 | TimeTicks | RO | mandatory | 0 (0d 0h 0m 0s) | ||||||||||||||||
scalar · TimeTicks · read-only · mandatory The UPS wasted battery time since the UPS has transfered to backup mode. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsBaseBatteryLastReplaceDate | 1.3.6.1.4.1.3808.1.1.1.2.1.3 | DisplayString | RW | mandatory | 06/30/2026 | ||||||||||||||||
scalar · DisplayString · read-write · mandatory The UPS batteries last replaced date in mm/dd/yyyy format. This value is originally set when manufactured. If batteries replaced, administrator should reset this value. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsBaseBatteryAgeRecommand | 1.3.6.1.4.1.3808.1.1.1.2.1.4 | INTEGER | RO | mandatory | 42 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory Recommended battery life in month Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsAdvanceBattery | 1.3.6.1.4.1.3808.1.1.1.2.2 | ||||||||||||||||||||
| SupsAdvanceBatteryCapacity | 1.3.6.1.4.1.3808.1.1.1.2.2.1 | Gauge | RO | mandatory | 100 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The battery capacity expressed in percentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceBatteryVoltage | 1.3.6.1.4.1.3808.1.1.1.2.2.2 | INTEGER | RO | mandatory | 240 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery voltage expressed in 1/10 VDC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceBatteryTemperature | 1.3.6.1.4.1.3808.1.1.1.2.2.3 | Gauge | RO | mandatory | 36 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The UPS battery temperature expressed in Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceBatteryRunTimeRemaining | 1.3.6.1.4.1.3808.1.1.1.2.2.4 | TimeTicks | RO | mandatory | 174000 (0d 0h 29m 0s) | ||||||||||||||||
scalar · TimeTicks · read-only · mandatory The UPS battery remaining run time. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceBatteryReplaceIndicator | 1.3.6.1.4.1.3808.1.1.1.2.2.5 | INTEGER | RO | mandatory | noBatteryNeedsReplacing(1) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory This value indicates if UPS batteries need to be replaced.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceBatteryFullChargeVoltage | 1.3.6.1.4.1.3808.1.1.1.2.2.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery charged voltage expressed in 1/10 VDC. | |||||||||||||||||||||
| SupsAdvanceBatteryCurrent | 1.3.6.1.4.1.3808.1.1.1.2.2.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery current expressed in percentage. | |||||||||||||||||||||
| SupsAdvanceBatteryVoltageRating | 1.3.6.1.4.1.3808.1.1.1.2.2.8 | INTEGER | RO | mandatory | 48 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The DC voltage rating of the battery set. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceBatteryLife | 1.3.6.1.4.1.3808.1.1.1.2.2.9 | INTEGER | RO | mandatory | | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery life expressed in 1/100 percentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsInput | 1.3.6.1.4.1.3808.1.1.1.3 | ||||||||||||||||||||
| NupsBaseInput | 1.3.6.1.4.1.3808.1.1.1.3.1 | ||||||||||||||||||||
| SupsBaseInputPhase | 1.3.6.1.4.1.3808.1.1.1.3.1.1 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The AC input phase. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsAdvanceInput | 1.3.6.1.4.1.3808.1.1.1.3.2 | ||||||||||||||||||||
| SupsAdvanceInputLineVoltage | 1.3.6.1.4.1.3808.1.1.1.3.2.1 | Gauge | RO | mandatory | 1195 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The input line voltage in 1/10 VAC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceInputMaxLineVoltage | 1.3.6.1.4.1.3808.1.1.1.3.2.2 | Gauge | RO | mandatory | 1211 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The maximum input line voltage in 1/10 VAC over the previous 1 minute period. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceInputMinLineVoltage | 1.3.6.1.4.1.3808.1.1.1.3.2.3 | Gauge | RO | mandatory | 1208 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The minimum input line voltage in 1/10 VAC over the previous 1 minute period. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceInputFrequency | 1.3.6.1.4.1.3808.1.1.1.3.2.4 | Gauge | RO | mandatory | 600 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The input line frequency in 1/10 Hz. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceInputLineFailCause | 1.3.6.1.4.1.3808.1.1.1.3.2.5 | INTEGER | RO | mandatory | noTransfer(1) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The reason of UPS power failure. This value is set to: - noTransfer(1), if UPS is in utility mode. - highLineVoltage(2), if UPS switch to battery mode by reason of input voltage over the high transfer vloltage. - brownout(3), if UPS switch to battery mode by reason of input voltage under the low transfer vloltage. - selfTest(4), if the UPS was commanded to do a self test.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceInputStatus | 1.3.6.1.4.1.3808.1.1.1.3.2.6 | INTEGER | RO | mandatory | normal(1) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory Display the present status of the utility power supplied to the UPS.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceInputWatt | 1.3.6.1.4.1.3808.1.1.1.3.2.7 | Gauge | RO | mandatory | |||||||||||||||||
scalar · Gauge · read-only · mandatory Getting this OID will return the input power that each phase of the UPS can provide. It is represented in Watt. | |||||||||||||||||||||
| NupsOutput | 1.3.6.1.4.1.3808.1.1.1.4 | ||||||||||||||||||||
| NupsBaseOutput | 1.3.6.1.4.1.3808.1.1.1.4.1 | ||||||||||||||||||||
| SupsBaseOutputStatus | 1.3.6.1.4.1.3808.1.1.1.4.1.1 | INTEGER | RO | mandatory | onLine(2) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The UPS output status.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsBaseOutputPhase | 1.3.6.1.4.1.3808.1.1.1.4.1.2 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The output phase. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsBaseOutputWorkingFrequency | 1.3.6.1.4.1.3808.1.1.1.4.1.3 | DisplayString | RO | mandatory | 47~53 Hz/57~63 Hz | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The frequency of the UPS output power. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsAdvanceOutput | 1.3.6.1.4.1.3808.1.1.1.4.2 | ||||||||||||||||||||
| SupsAdvanceOutputVoltage | 1.3.6.1.4.1.3808.1.1.1.4.2.1 | Gauge | RO | mandatory | 1202 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The UPS output voltage in 1/10 VAC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceOutputFrequency | 1.3.6.1.4.1.3808.1.1.1.4.2.2 | Gauge | RO | mandatory | 600 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The UPS output frequency in 1/10 Hz. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceOutputLoad | 1.3.6.1.4.1.3808.1.1.1.4.2.3 | Gauge | RO | mandatory | 24 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The UPS output load expressed in percentage Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceOutputCurrent | 1.3.6.1.4.1.3808.1.1.1.4.2.4 | Gauge | RO | mandatory | 65 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The UPS output current in 1/10 Amps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceOutputPower | 1.3.6.1.4.1.3808.1.1.1.4.2.5 | Gauge | RO | mandatory | 69 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The total output active power of the UPS system in W. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceOutputEnergy | 1.3.6.1.4.1.3808.1.1.1.4.2.6 | Gauge | RO | mandatory | 508 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The total output energy of the UPS system in 1/10 kWh. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceOutputEnergyStartTime | 1.3.6.1.4.1.3808.1.1.1.4.2.7 | DisplayString | RO | mandatory | 06/24/2026 05:06:42 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory Indicates the date and time of the last device energy meter reset. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceApparentOutputPower | 1.3.6.1.4.1.3808.1.1.1.4.2.8 | Gauge | RO | mandatory | 74 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The total output apparent power of the UPS system in VA. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsConfig | 1.3.6.1.4.1.3808.1.1.1.5 | ||||||||||||||||||||
| NupsBaseConfig | 1.3.6.1.4.1.3808.1.1.1.5.1 | ||||||||||||||||||||
| SupsBaseConfigNumDevices | 1.3.6.1.4.1.3808.1.1.1.5.1.1 | INTEGER | RO | mandatory | 24 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of equipment plugged into the UPS. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TupsBaseConfigDeviceTable | 1.3.6.1.4.1.3808.1.1.1.5.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of equipment plugged into the UPS. The numbers of entries are given by the value of upsBaseConfigNumDevices. | |||||||||||||||||||||
| RupsBaseConfigDeviceEntry | 1.3.6.1.4.1.3808.1.1.1.5.1.2.1 | NA | mandatory | ||||||||||||||||||
| CdeviceIndex | 1.3.6.1.4.1.3808.1.1.1.5.1.2.1.1 | INTEGER (1..255) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..255) · read-only · mandatory The index of the equipment plugged into the UPS. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CdeviceName | 1.3.6.1.4.1.3808.1.1.1.5.1.2.1.2 | DisplayString | RW | mandatory | Outlet1 | ||||||||||||||||
column · DisplayString · read-write · mandatory The name of the equipment plugged into the UPS. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CvaRating | 1.3.6.1.4.1.3808.1.1.1.5.1.2.1.3 | INTEGER | RW | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-write · mandatory The VA rating of the equipment plugged into the UPS. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CacceptThisDevice | 1.3.6.1.4.1.3808.1.1.1.5.1.2.1.4 | INTEGER | RW | mandatory | no(2) | ||||||||||||||||
column · INTEGER · read-write · mandatory An equipment is plugged if yes, unplugged if no.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsAdvanceConfig | 1.3.6.1.4.1.3808.1.1.1.5.2 | ||||||||||||||||||||
| SupsAdvanceConfigOutputVoltage | 1.3.6.1.4.1.3808.1.1.1.5.2.1 | INTEGER | RW | mandatory | 120 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The standard UPS output voltage in VAC. The possible values are 100, 110, 120, 127, 208, 220, 230, and 240. If a value other than a possible value is set, it will not be accepted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigHighTransferVolt | 1.3.6.1.4.1.3808.1.1.1.5.2.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Adjust the high transfer vloltage in VAC. The high transfer vloltage will become the UPS default value subtracts this value. The allowed values depend on the output: 100-127 volt system allow settings of 0-15. 208-240 volt system allow settings of 0-30. If the adjustable value is over the allowed values, it will not be accepted. | |||||||||||||||||||||
| SupsAdvanceConfigLowTransferVolt | 1.3.6.1.4.1.3808.1.1.1.5.2.3 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Adjust the low transfer vloltage in VAC. The low transfer vloltage will become the UPS default value adds this value. The allowed values depend on the output: 100-127 volt system allow settings of 0-15. 208-240 volt system allow settings of 0-30. If the adjustable value is over the allowed values, it will not be accepted. | |||||||||||||||||||||
| SupsAdvanceConfigAlarm | 1.3.6.1.4.1.3808.1.1.1.5.2.4 | INTEGER | RW | mandatory | enable(2) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory This value is set to handle audible alarms when power failure.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigAlarmTimer | 1.3.6.1.4.1.3808.1.1.1.5.2.5 | TimeTicks | RW | mandatory | |||||||||||||||||
scalar · TimeTicks · read-write · mandatory The time after power failure at which the UPS begins giving audible alarms. This timer is effective only if the value of upsAdvanceConfigAlarm is timed(1). Accepted values are between 0 to 60 seconds. If a value other than a supported value is set, the value will not be accepted. | |||||||||||||||||||||
| SupsAdvanceConfigMinReturnCapacity | 1.3.6.1.4.1.3808.1.1.1.5.2.6 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The minimum battery capacity that UPS will return from a low battery shutdown condition. The possible values are between 0 to 40. If a value other than a supported value is set, the value will not be accepted. | |||||||||||||||||||||
| SupsAdvanceConfigSensitivity | 1.3.6.1.4.1.3808.1.1.1.5.2.7 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The sensitivity of the UPS to power failure detection.
| |||||||||||||||||||||
| SupsAdvanceConfigLowBatteryRunTime | 1.3.6.1.4.1.3808.1.1.1.5.2.8 | TimeTicks | RW | mandatory | |||||||||||||||||
scalar · TimeTicks · read-write · mandatory The desired run time, in seconds, UPS will enter in a low battery sequence. The possible values are 120, 300, 420, 600. If a value other than a supported value is set, the value will not be accepted. | |||||||||||||||||||||
| SupsAdvanceConfigReturnDelay | 1.3.6.1.4.1.3808.1.1.1.5.2.9 | TimeTicks | RW | mandatory | 0 (0d 0h 0m 0s) | ||||||||||||||||
scalar · TimeTicks · read-write · mandatory The delay time the UPS will turn on after power recovery. The value is also used in a 'reboot' or 'wake up' sequence. The possible values are 0 to 600 seconds. If a value other than a supported value is set, the value will not be accepted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigShutoffDelay | 1.3.6.1.4.1.3808.1.1.1.5.2.10 | TimeTicks | RW | mandatory | 18000 (0d 0h 3m 0s) | ||||||||||||||||
scalar · TimeTicks · read-write · mandatory The delay time the UPS will remain on after receiving a turn off command. The possible values are between 60 to 5940 seconds. If a value other than a supported value is set, the value will not be accepted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigSleepDelay | 1.3.6.1.4.1.3808.1.1.1.5.2.11 | TimeTicks | RW | mandatory | 18000 (0d 0h 3m 0s) | ||||||||||||||||
scalar · TimeTicks · read-write · mandatory The delay time the UPS will enter sleep mode after receiving a sleep command. WThe possible values are between 60 to 5940 seconds. If a value other than a supported value is set, the value will not be accepted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigSetEEPROMDefaults | 1.3.6.1.4.1.3808.1.1.1.5.2.12 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Reset the UPS EEPROM parameters to default values.
| |||||||||||||||||||||
| SupsAdvanceConfigAutoRestore | 1.3.6.1.4.1.3808.1.1.1.5.2.13 | INTEGER | RW | mandatory | | ||||||||||||||||
scalar · INTEGER · read-write · mandatory When this option is enabled, the UPS will restore output immediately when the utility power restores.When this option is disabled, the UPS will not restore output at that moment and users have to turn it on manually at a later time.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigRechargedCapacity | 1.3.6.1.4.1.3808.1.1.1.5.2.14 | INTEGER | RW | mandatory | 0 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory When the utility power restores, the UPS will start to recharge until the specified battery capacity in percentage is met before restoring output power. The possible values are 0, 15, 30, 45, 60, 75, and 90. If a value other than a possible value is set, it will not be accepted. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigColdStart | 1.3.6.1.4.1.3808.1.1.1.5.2.15 | INTEGER | RW | mandatory | enable(2) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory Set the ability of the UPS can start in the absence of input power.When this option is enabled the UPS can be turned on without having input power.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigDeepDischargeProtection | 1.3.6.1.4.1.3808.1.1.1.5.2.16 | INTEGER | RW | mandatory | 0 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory When the UPS is on Battery Mode with 0% load and the status remains for
the time configured,the RMCARD will enforce the UPS to Sleep Mode and
the output will be turned off. The possible values are 0, 20, 40, and 60 minutes.
If a value other than a possible value is set, it will not be accepted.Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigSleepAfterAllClientShut | 1.3.6.1.4.1.3808.1.1.1.5.2.17 | INTEGER | RW | mandatory | disable(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory If this option is enabled, UPS will enter sleep mode after utility power failed and remaining MSDT+2 minutes.More information about MSDT please reference to help page of UPS - > PowerPanel List.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigLowBatteryThreshold | 1.3.6.1.4.1.3808.1.1.1.5.2.18 | INTEGER | RW | mandatory | 35 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory When the UPS supplies battery power and the remaining capacity is lower than this threshold, the UPS will sound an alarm. The value expressed in percentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigEnergyReset | 1.3.6.1.4.1.3808.1.1.1.5.2.19 | INTEGER | RW | mandatory | noOperation(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the output energy meter value to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceConfigBatteryRuntimeThreshold | 1.3.6.1.4.1.3808.1.1.1.5.2.20 | INTEGER | RW | mandatory | 5 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory When the UPS supplies battery power and the remaining runtime is lower than this threshold, the UPS will sound an alarm. The value expressed in minutes. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsControl | 1.3.6.1.4.1.3808.1.1.1.6 | ||||||||||||||||||||
| NupsBaseControl | 1.3.6.1.4.1.3808.1.1.1.6.1 | ||||||||||||||||||||
| SupsBaseControlConserveBattery | 1.3.6.1.4.1.3808.1.1.1.6.1.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS on battery will enter sleeping when the variable is set to turnOffUpsToConserveBattery(2). When utility power recovers the UPS will turn back on. Trying to turn off a UPS that is not on battery mode will cause badValue error. It is no effective to set this value to noTurnOffUps(1).
| |||||||||||||||||||||
| NupsAdvanceControl | 1.3.6.1.4.1.3808.1.1.1.6.2 | ||||||||||||||||||||
| SupsAdvanceControlUpsOff | 1.3.6.1.4.1.3808.1.1.1.6.2.1 | INTEGER | RW | mandatory | noTurnUpsOff(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will shutdown when the variable is set to turnUpsOff(2). UPS will shutdown after a delay period specified by upsAdvanceConfigShutoffDelay when the variable is Set to turnUpsOffGracefully(3). Without regard to the utility state the UPS will not provide output power in this state. It is no effective to set this value to noTurnUpsOff(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceControlRebootUps | 1.3.6.1.4.1.3808.1.1.1.6.2.2 | INTEGER | RW | mandatory | noRebootUps(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will shutdown and turn back on when the variable is set to rebootUps(2). It is no effective to set this value to noRebootUps(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceControlUpsSleep | 1.3.6.1.4.1.3808.1.1.1.6.2.3 | INTEGER | RW | mandatory | noPutUpsToSleep(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will enter sleep mode when the variable is set to putUpsToSleep(2). UPS will enter sleep mode after a delay period specified by upsAdvanceConfigSleepDelay when the variable is Set to putUpsToSleepGracefully(3). Without regard to the utility state the UPS will not provide output power in sleep mode. Output power will recover when specified time has elapsed. It is no effective to set this value to noPutUpsToSleep(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceControlSimulatePowerFail | 1.3.6.1.4.1.3808.1.1.1.6.2.4 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will transfer to backup mode when the variable is set to simulatePowerFailure(2). It is no effective to set this value to noFlashAndBeep(1).
| |||||||||||||||||||||
| SupsAdvanceControlFlashAndBeep | 1.3.6.1.4.1.3808.1.1.1.6.2.5 | INTEGER | RW | mandatory | noFlashAndBeep(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will beep and simultaneously turn on the panel lights when the variable is set to flashAndBeep(2). It is no effective to set this value to noSimulatePowerFailure(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceControlTurnOnUPS | 1.3.6.1.4.1.3808.1.1.1.6.2.6 | INTEGER | RW | mandatory | noTurnOnUPS(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will turned on immediately when the variable is set to turnOnUPS(2). It is no effective to set this value to noTurnOnUPS(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceSleepAfterDelay | 1.3.6.1.4.1.3808.1.1.1.6.2.7 | INTEGER (-1..600) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (-1..600) · read-write · mandatory UPS will enter sleep mode after indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown.
| |||||||||||||||||||||
| NupsTest | 1.3.6.1.4.1.3808.1.1.1.7 | ||||||||||||||||||||
| NupsBaseTest | 1.3.6.1.4.1.3808.1.1.1.7.1 | ||||||||||||||||||||
| NupsAdvanceTest | 1.3.6.1.4.1.3808.1.1.1.7.2 | ||||||||||||||||||||
| SupsAdvanceTestDiagnosticSchedule | 1.3.6.1.4.1.3808.1.1.1.7.2.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The schedule of the UPS automatic selftest.
| |||||||||||||||||||||
| SupsAdvanceTestDiagnostics | 1.3.6.1.4.1.3808.1.1.1.7.2.2 | INTEGER | RW | mandatory | noTestDiagnostics(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will do a diagnostic selftest when the variable is set to testDiagnostics(2). It is no effective to set this value to noTestDiagnostics(1).
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceTestDiagnosticsResults | 1.3.6.1.4.1.3808.1.1.1.7.2.3 | INTEGER | RO | mandatory | | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The last UPS selftest result.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceTestLastDiagnosticsDate | 1.3.6.1.4.1.3808.1.1.1.7.2.4 | DisplayString | RO | mandatory | | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The last UPS selftest date in mm/dd/yy format. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceTestIndicators | 1.3.6.1.4.1.3808.1.1.1.7.2.5 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will perform a panel indicator test when the variable is set to testIndicators(2). It is no effective to set this value to noTestIndicators(1).
| |||||||||||||||||||||
| SupsAdvanceTestRuntimeEstimation | 1.3.6.1.4.1.3808.1.1.1.7.2.6 | INTEGER | RW | mandatory | noPerformEstimation(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory UPS will discharge to calibrate the UPS runtime when the variable is set to performEstimation(2). This test runs until the UPS is in a low battery condition. UPS will cancel the discharge after setting performEstimation(2) when the variable is set to cancelCurrentEstimation(3). It is no effective to set this value to noPerformEstimation(1). The result of the runtime test will be stored in upsAdvanceTestEstimationResults.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceTestEstimationResults | 1.3.6.1.4.1.3808.1.1.1.7.2.7 | INTEGER | RO | mandatory | | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The last runtime estimation result. This value means : - ok(1), if a successful runtime estimation. - invalidEstimation(2), if runtime estimation failure. - estimationInProgress(3), if estimation is processing now.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsAdvanceTestEstimationDate | 1.3.6.1.4.1.3808.1.1.1.7.2.8 | DisplayString | RO | mandatory | | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The last UPS runtime estimation date Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsOutlet | 1.3.6.1.4.1.3808.1.1.1.8 | ||||||||||||||||||||
| NupsBankOutletControl | 1.3.6.1.4.1.3808.1.1.1.8.1 | ||||||||||||||||||||
| TupsBankOutletControlTable | 1.3.6.1.4.1.3808.1.1.1.8.1.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for control of the outlet banks. | |||||||||||||||||||||
| RupsBankOutletControlEntry | 1.3.6.1.4.1.3808.1.1.1.8.1.1.1 | NA | mandatory | ||||||||||||||||||
| CupsBankControlIndex | 1.3.6.1.4.1.3808.1.1.1.8.1.1.1.1 | INTEGER (1..24) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..24) · read-only · mandatory The index to the outlet entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CupsBankControlOutletCommand | 1.3.6.1.4.1.3808.1.1.1.8.1.1.1.2 | INTEGER | RW | mandatory | criticalBank(4) | ||||||||||||||||
column · INTEGER · read-write · mandatory Getting this variable will return the outlet bank state. If the outlet bank is on, the immediateOn (1) value will be returned. If the outlet bank is off, the immediateOff (2) value will be returned. If the outlet bank is critical (uncontrollable), the criticalBank (4) value will be returned. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NupsIndividualOutlet | 1.3.6.1.4.1.3808.1.1.1.8.2 | ||||||||||||||||||||
| SupsIndividualOutletTableSize | 1.3.6.1.4.1.3808.1.1.1.8.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of switched outlets | |||||||||||||||||||||
| TupsIndividualOutletConfigTable | 1.3.6.1.4.1.3808.1.1.1.8.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of switched outlet configuration data. | |||||||||||||||||||||
| RupsIndividualOutletConfigEntry | 1.3.6.1.4.1.3808.1.1.1.8.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from currently queried switched outlet. | |||||||||||||||||||||
| CupsIndividualOutletConfigIndex | 1.3.6.1.4.1.3808.1.1.1.8.2.2.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the switched outlet configuration table entry. | |||||||||||||||||||||
| CupsIndividualOutletConfigName | 1.3.6.1.4.1.3808.1.1.1.8.2.2.1.2 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The user-defined switched outlet name string. | |||||||||||||||||||||
| CupsIndividualOutletConfigPowerOnTime | 1.3.6.1.4.1.3808.1.1.1.8.2.2.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 - never power on. 0 - power on immediately. 1 to 7200 - power on up to 7200 seconds after being commanded. | |||||||||||||||||||||
| CupsIndividualOutletConfigPowerOffTime | 1.3.6.1.4.1.3808.1.1.1.8.2.2.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never power off. 0 - power off immediately. 1 to 7200 - power off up to 7200 seconds after being commanded. | |||||||||||||||||||||
| CupsIndividualOutletConfigRebootDuration | 1.3.6.1.4.1.3808.1.1.1.8.2.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute). | |||||||||||||||||||||
| TupsIndividualOutletInfoTable | 1.3.6.1.4.1.3808.1.1.1.8.2.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of switched outlet information. | |||||||||||||||||||||
| RupsIndividualOutletInfoEntry | 1.3.6.1.4.1.3808.1.1.1.8.2.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Information of the currently queried switched outlet. | |||||||||||||||||||||
| CupsIndividualOutletInfoIndex | 1.3.6.1.4.1.3808.1.1.1.8.2.3.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the switched outlet information table entry. | |||||||||||||||||||||
| CupsIndividualOutletInfoName | 1.3.6.1.4.1.3808.1.1.1.8.2.3.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The numeric switched outlet name. | |||||||||||||||||||||
| CupsIndividualOutletInfoBank | 1.3.6.1.4.1.3808.1.1.1.8.2.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric bank ID. | |||||||||||||||||||||
| TupsIndividualOutletStatusTable | 1.3.6.1.4.1.3808.1.1.1.8.2.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of switched outlet status information. | |||||||||||||||||||||
| RupsIndividualOutletStatusEntry | 1.3.6.1.4.1.3808.1.1.1.8.2.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status information for currently queried switched outlet. | |||||||||||||||||||||
| CupsIndividualOutletStatusIndex | 1.3.6.1.4.1.3808.1.1.1.8.2.4.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the switched outlet status information table entry. | |||||||||||||||||||||
| CupsIndividualOutletStatusName | 1.3.6.1.4.1.3808.1.1.1.8.2.4.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined switched outlet name string. | |||||||||||||||||||||
| CupsIndividualOutletStatusState | 1.3.6.1.4.1.3808.1.1.1.8.2.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the present switch state of the switched outlet being queried.
| |||||||||||||||||||||
| CupsIndividualOutletStatusCommandPending | 1.3.6.1.4.1.3808.1.1.1.8.2.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned.
| |||||||||||||||||||||
| TupsIndividualOutletControlTable | 1.3.6.1.4.1.3808.1.1.1.8.2.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of switched outlet control data. | |||||||||||||||||||||
| RupsIndividualOutletControlEntry | 1.3.6.1.4.1.3808.1.1.1.8.2.5.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Control data for currently queried switched outlet. | |||||||||||||||||||||
| CupsIndividualOutletControlIndex | 1.3.6.1.4.1.3808.1.1.1.8.2.5.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the switched outlet control data table entry. | |||||||||||||||||||||
| CupsIndividualOutletControlName | 1.3.6.1.4.1.3808.1.1.1.8.2.5.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined switched outlet name string. | |||||||||||||||||||||
| CupsIndividualOutletControlCommand | 1.3.6.1.4.1.3808.1.1.1.8.2.5.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will immediately reboot the outlet. Setting this variable to delayedOn (4) will turn the outlet on after the upsIndividualOutletConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (5) will turn the outlet off after the upsIndividualOutletConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (6) will cause the switched outlet to perform a delayedOff command, wait the upsIndividualOutletConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (7) will cause any pending command to this outlet to be canceled.
| |||||||||||||||||||||
| NupsPhase | 1.3.6.1.4.1.3808.1.1.1.9 | ||||||||||||||||||||
| NupsPhaseInput | 1.3.6.1.4.1.3808.1.1.1.9.1 | ||||||||||||||||||||
| SupsPhaseInputTableSize | 1.3.6.1.4.1.3808.1.1.1.9.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the phase number. | |||||||||||||||||||||
| TupsPhaseInputTable | 1.3.6.1.4.1.3808.1.1.1.9.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Phase Input in the UPS | |||||||||||||||||||||
| RupsPhaseInputEntry | 1.3.6.1.4.1.3808.1.1.1.9.1.2.1 | NA | mandatory | ||||||||||||||||||
| CupsPhaseInputTableIndex | 1.3.6.1.4.1.3808.1.1.1.9.1.2.1.1 | INTEGER (3) | RO | mandatory | |||||||||||||||||
column · INTEGER (3) · read-only · mandatory The index to the UPS Phase Input entry. | |||||||||||||||||||||
| CupsPhaseInputVoltage | 1.3.6.1.4.1.3808.1.1.1.9.1.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the input voltage that each phase of the UPS can provide. It is represented in 1/10 VAC. | |||||||||||||||||||||
| CupsPhaseInputCurrent | 1.3.6.1.4.1.3808.1.1.1.9.1.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the input current that each phase of the UPS can provide. It is represented in 1/10 Amps. | |||||||||||||||||||||
| CupsPhaseInputFrequency | 1.3.6.1.4.1.3808.1.1.1.9.1.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the input frequency that each phase of the UPS can provide. It is represented in 1/10 Hz. | |||||||||||||||||||||
| CupsPhaseInputPowerFactor | 1.3.6.1.4.1.3808.1.1.1.9.1.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the input power factor that each phase of the UPS can provide. It is represented in 1/100. | |||||||||||||||||||||
| NupsPhaseOutput | 1.3.6.1.4.1.3808.1.1.1.9.2 | ||||||||||||||||||||
| SupsPhaseOutputTableSize | 1.3.6.1.4.1.3808.1.1.1.9.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the Phase number. | |||||||||||||||||||||
| TupsPhaseOutputTable | 1.3.6.1.4.1.3808.1.1.1.9.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Phase Output in the UPS | |||||||||||||||||||||
| RupsPhaseOutputEntry | 1.3.6.1.4.1.3808.1.1.1.9.2.2.1 | NA | mandatory | ||||||||||||||||||
| CupsPhaseOutputTableIndex | 1.3.6.1.4.1.3808.1.1.1.9.2.2.1.1 | INTEGER (3) | RO | mandatory | |||||||||||||||||
column · INTEGER (3) · read-only · mandatory The index to the UPS Phase Output entry. | |||||||||||||||||||||
| CupsPhaseOutputVoltage | 1.3.6.1.4.1.3808.1.1.1.9.2.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the output voltage that each phase of the UPS can provide. It is represented in 1/10 VAC. | |||||||||||||||||||||
| CupsPhaseOutputCurrent | 1.3.6.1.4.1.3808.1.1.1.9.2.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the output current that each phase of the UPS can provide. It is represented in 1/10 Amps. | |||||||||||||||||||||
| CupsPhaseOutputFrequency | 1.3.6.1.4.1.3808.1.1.1.9.2.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the output frequency that each phase of the UPS can provide. It is represented in 1/10 Hz. | |||||||||||||||||||||
| CupsPhaseOutputPowerFactor | 1.3.6.1.4.1.3808.1.1.1.9.2.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the output power factor that each phase of the UPS can provide. It is represented in 1/100. | |||||||||||||||||||||
| CupsPhaseOutputPower | 1.3.6.1.4.1.3808.1.1.1.9.2.2.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the output power that each phase of the UPS can provide. It is represented in Watt. | |||||||||||||||||||||
| NupsPhaseBypass | 1.3.6.1.4.1.3808.1.1.1.9.3 | ||||||||||||||||||||
| SupsPhaseBypassTableSize | 1.3.6.1.4.1.3808.1.1.1.9.3.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the Phase number. | |||||||||||||||||||||
| TupsPhaseBypassTable | 1.3.6.1.4.1.3808.1.1.1.9.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Phase Bypass in the UPS | |||||||||||||||||||||
| RupsPhaseBypassEntry | 1.3.6.1.4.1.3808.1.1.1.9.3.2.1 | NA | mandatory | ||||||||||||||||||
| CupsPhaseBypassTableIndex | 1.3.6.1.4.1.3808.1.1.1.9.3.2.1.1 | INTEGER (3) | RO | mandatory | |||||||||||||||||
column · INTEGER (3) · read-only · mandatory The index to the UPS Phase Bypass entry. | |||||||||||||||||||||
| CupsPhaseBypassVoltage | 1.3.6.1.4.1.3808.1.1.1.9.3.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bypass voltage that each phase of the UPS can provide. It is represented in 1/10 VAC. | |||||||||||||||||||||
| CupsPhaseBypassCurrent | 1.3.6.1.4.1.3808.1.1.1.9.3.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bypass current that each phase of the UPS can provide. It is represented in 1/10 Amps. | |||||||||||||||||||||
| CupsPhaseBypassFrequency | 1.3.6.1.4.1.3808.1.1.1.9.3.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bypass frequency that each phase of the UPS can provide. It is represented in 1/10 Hz. | |||||||||||||||||||||
| CupsPhaseBypassPowerFactor | 1.3.6.1.4.1.3808.1.1.1.9.3.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bypass power factor that each phase of the UPS can provide. It is represented in 1/100. | |||||||||||||||||||||
| NupsSystem | 1.3.6.1.4.1.3808.1.1.1.10 | ||||||||||||||||||||
| SupsStatus | 1.3.6.1.4.1.3808.1.1.1.10.1 | INTEGER | RO | mandatory | normal(1) | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The UPS system status.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsTemperature | 1.3.6.1.4.1.3808.1.1.1.10.2 | Gauge | RO | mandatory | 27 | ||||||||||||||||
scalar · Gauge · read-only · mandatory The UPS NTC temperature expressed in Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SupsFaultCode | 1.3.6.1.4.1.3808.1.1.1.10.3 | DisplayString | RO | mandatory | | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The UPS Hardware Fault code. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Neswitch | 1.3.6.1.4.1.3808.1.1.2 | ||||||||||||||||||||
| NeSwitchIdent | 1.3.6.1.4.1.3808.1.1.2.1 | ||||||||||||||||||||
| SeSwitchIdentHardwareRev | 1.3.6.1.4.1.3808.1.1.2.1.1 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The hardware revision set at the factory. | |||||||||||||||||||||
| SeSwitchIdentFirmwareRev | 1.3.6.1.4.1.3808.1.1.2.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The firmware revision set at the factory. | |||||||||||||||||||||
| SeSwitchIdentDateOfManufacture | 1.3.6.1.4.1.3808.1.1.2.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The manufacture date in mm/dd/yy format. | |||||||||||||||||||||
| SeSwitchIdentModelName | 1.3.6.1.4.1.3808.1.1.2.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The model name set at the factory. This value need to consist with safty report. | |||||||||||||||||||||
| NeSwitchBase | 1.3.6.1.4.1.3808.1.1.2.2 | ||||||||||||||||||||
| SeSwitchNumber | 1.3.6.1.4.1.3808.1.1.2.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The numbers of switch have been attached to the system. | |||||||||||||||||||||
| TeSwitchBaseTable | 1.3.6.1.4.1.3808.1.1.2.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of switch information. The number of entries is given by the value of eSwitchNumber. | |||||||||||||||||||||
| ReSwitchBaseEntry | 1.3.6.1.4.1.3808.1.1.2.2.2.1 | NA | mandatory | ||||||||||||||||||
| CeSwitchID | 1.3.6.1.4.1.3808.1.1.2.2.2.1.1 | INTEGER (0..16) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..16) · read-only · mandatory The power switch ID number. | |||||||||||||||||||||
| CeSwitchOutletNum | 1.3.6.1.4.1.3808.1.1.2.2.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of outlets provided in the switch. | |||||||||||||||||||||
| CeSwitchOutletState | 1.3.6.1.4.1.3808.1.1.2.2.2.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Getting this OID will reply the status of all outlets in the switch. '0' for outlet off, '1' for outlet on. The index from left to right is outlet#8, #7, #6, #5, #4, #3, #2, #1. For Example: If the string is '01011010', it means the outlets status are the following: outlet #8 is off, outlet #7 is on, outlet #6 is off, outlet #5 is on, outlet #4 is on, outlet #3 is off, outlet #2 is on, outlet #1 is off. | |||||||||||||||||||||
| TeSwitchBaseCtrTable | 1.3.6.1.4.1.3808.1.1.2.2.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of switch control parameters. The number of entries is given by the value of eSwitchNumber. | |||||||||||||||||||||
| ReSwitchBaseCtrEntry | 1.3.6.1.4.1.3808.1.1.2.2.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry control information of individual switches.
| |||||||||||||||||||||
| CeSwitchCtrID | 1.3.6.1.4.1.3808.1.1.2.2.3.1.1 | INTEGER (0..16) | RW | mandatory | |||||||||||||||||
column · INTEGER (0..16) · read-write · mandatory Select the switch ID to be controlled. | |||||||||||||||||||||
| CeSwitchActOutlet | 1.3.6.1.4.1.3808.1.1.2.2.3.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The action outlets to be controlled. | |||||||||||||||||||||
| CeSwitchActType | 1.3.6.1.4.1.3808.1.1.2.2.3.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The on/off type of the action outlets. 1 for duration off, 2 for duration on, 3 for immediately off, 4 for immediately on, and 5 for reboot. | |||||||||||||||||||||
| NePDU | 1.3.6.1.4.1.3808.1.1.3 | ||||||||||||||||||||
| NePDUIdent | 1.3.6.1.4.1.3808.1.1.3.1 | ||||||||||||||||||||
| SePDUIdentName | 1.3.6.1.4.1.3808.1.1.3.1.1 | DisplayString | RW | mandatory | |||||||||||||||||
scalar · DisplayString · read-write · mandatory The name of the Rack PDU. The maximum string size is device dependent. | |||||||||||||||||||||
| SePDUIdentHardwareRev | 1.3.6.1.4.1.3808.1.1.3.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The hardware revision of the Rack PDU. This value is set at the factory. | |||||||||||||||||||||
| SePDUIdentFirmwareRev | 1.3.6.1.4.1.3808.1.1.3.1.3 | DisplayString | RO | mandatory | 1.3.4 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory An 8-byte ID string identifying the Rack PDU firmware revision. This value is set at the factory. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SePDUIdentDateOfManufacture | 1.3.6.1.4.1.3808.1.1.3.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The date when the Rack PDU was manufactured in mm/dd/yyyy format. This value is set at the factory. The year 2000 will be represented by 00. | |||||||||||||||||||||
| SePDUIdentModelNumber | 1.3.6.1.4.1.3808.1.1.3.1.5 | DisplayString | RO | mandatory | PDU81005 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory A 10-character string identifying the model number of the Rack PDU. This value is set at the factory. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SePDUIdentSerialNumber | 1.3.6.1.4.1.3808.1.1.3.1.6 | DisplayString | RO | mandatory | NKVQV2000013 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory A 12-character string identifying the serial number of the Rack PDU. This value is set at the factory. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SePDUIdentDeviceRating | 1.3.6.1.4.1.3808.1.1.3.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the electrical rating of the device. | |||||||||||||||||||||
| SePDUIdentDeviceNumOutlets | 1.3.6.1.4.1.3808.1.1.3.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the number of outlets contained in the device. | |||||||||||||||||||||
| SePDUIdentDeviceNumPhases | 1.3.6.1.4.1.3808.1.1.3.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the number of phases supported by the device. | |||||||||||||||||||||
| SePDUIdentDeviceNumBreakers | 1.3.6.1.4.1.3808.1.1.3.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the number of circuit breakers supported by the device. This is the same as the number of banks of outlets. 0 will be returned if the unit has no phase breakers. | |||||||||||||||||||||
| SePDUIdentDeviceBreakerRating | 1.3.6.1.4.1.3808.1.1.3.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return rating of the circuit breakers on the device if it has any. | |||||||||||||||||||||
| SePDUIdentDeviceOrientation | 1.3.6.1.4.1.3808.1.1.3.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the intended physical orientation of the device. OrientHorizonatal(1) indicates Horizontal. OrientVertical(2) indicates Vertical.
| |||||||||||||||||||||
| SePDUIdentDeviceOutletLayout | 1.3.6.1.4.1.3808.1.1.3.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return outlet layout for the device. SeqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... SeqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... SeqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... SeqPhToPhGrouped(4) indicates outlet layout as follows: Otlts1-8::(3-1),Otlts9-16::(2-3),Otlts17-24::(1-2).
| |||||||||||||||||||||
| SePDUIdentDeviceDisplayOrientation | 1.3.6.1.4.1.3808.1.1.3.1.14 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Getting this OID will return the intended physical orientation of the Seven-Segment Display. displayNormal(1) indicates Normal. displayReverse(2)indicates Upside-Down. displayRotate90(3) indicates rotate 90 degree. displayRotate270(4) indicates rotate 270 degree. displayAuto(5) indicates auto-detect and rotate.
| |||||||||||||||||||||
| SePDUIdentDeviceLinetoLineVoltage | 1.3.6.1.4.1.3808.1.1.3.1.15 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Getting/Setting this OID will return/set the Line to Line Volatage. The valid range is between 0V to 440V | |||||||||||||||||||||
| SePDUIdentIndicator | 1.3.6.1.4.1.3808.1.1.3.1.16 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory PDU will perform a panel indicator test when the variable is set to testIndicators(2). It is no effective to set this value to noTestIndicators(1).
| |||||||||||||||||||||
| NePDULoad | 1.3.6.1.4.1.3808.1.1.3.2 | ||||||||||||||||||||
| NePDULoadDevice | 1.3.6.1.4.1.3808.1.1.3.2.1 | ||||||||||||||||||||
| SePDULoadDevMaxPhaseLoad | 1.3.6.1.4.1.3808.1.1.3.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the maximum rated power that each phase of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the unit is banked. | |||||||||||||||||||||
| SePDULoadDevNumPhases | 1.3.6.1.4.1.3808.1.1.3.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of phases available with this Rack PDU. | |||||||||||||||||||||
| SePDULoadDevMaxBankLoad | 1.3.6.1.4.1.3808.1.1.3.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the maximum rated power that a bank of the Rack PDU can provide. It is represented in Amps. 0 will be returned if the device does not have any banks. | |||||||||||||||||||||
| SePDULoadDevNumBanks | 1.3.6.1.4.1.3808.1.1.3.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of banks of outlets available with this Rack PDU. A bank of outlets has a unique circuit breaker for a subset of the total number of outlets on the ePDU. 0 will be returned if the unit no banks. | |||||||||||||||||||||
| SePDULoadDevBankTableSize | 1.3.6.1.4.1.3808.1.1.3.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Bank Table. | |||||||||||||||||||||
| TePDULoadDevBankTable | 1.3.6.1.4.1.3808.1.1.3.2.1.6 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Bank Max Load in the Rack PDU. | |||||||||||||||||||||
| RePDULoadDevBankEntry | 1.3.6.1.4.1.3808.1.1.3.2.1.6.1 | NA | mandatory | ||||||||||||||||||
| CePDULoadDevBankIndex | 1.3.6.1.4.1.3808.1.1.3.2.1.6.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to the Rack PDU bank entry. | |||||||||||||||||||||
| CePDULoadDevBankNumber | 1.3.6.1.4.1.3808.1.1.3.2.1.6.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bank number. | |||||||||||||||||||||
| CePDULoadDevBankMaxLoad | 1.3.6.1.4.1.3808.1.1.3.2.1.6.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the maximum rated power that each bank of the Rack PDU can provide. It is represented in Amps. | |||||||||||||||||||||
| SePDULoadDevMaxOutletTableSize | 1.3.6.1.4.1.3808.1.1.3.2.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Outlet Table. | |||||||||||||||||||||
| TePDULoadDevMaxOutletTable | 1.3.6.1.4.1.3808.1.1.3.2.1.8 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU. | |||||||||||||||||||||
| RePDULoadDevMaxOutletEntry | 1.3.6.1.4.1.3808.1.1.3.2.1.8.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory This gives access to Max Outlet Load of an Outlet Monitored Rack PDU | |||||||||||||||||||||
| CePDULoadDevOutletIndex | 1.3.6.1.4.1.3808.1.1.3.2.1.8.1.1 | INTEGER (1..24) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..24) · read-only · mandatory The index to the Outlet Monitored Rack PDU Max Outlet Load entry. | |||||||||||||||||||||
| CePDULoadDevOutletNumber | 1.3.6.1.4.1.3808.1.1.3.2.1.8.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the Outlet number. | |||||||||||||||||||||
| CePDULoadDevMaxOutletLoad | 1.3.6.1.4.1.3808.1.1.3.2.1.8.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the maximum rated power that each Outlet of an Outlet Monitored Rack PDU can provide. It is represented in Amps. | |||||||||||||||||||||
| NePDULoadPhaseConfig | 1.3.6.1.4.1.3808.1.1.3.2.2 | ||||||||||||||||||||
| TePDULoadPhaseConfigTable | 1.3.6.1.4.1.3808.1.1.3.2.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for configuration of each Rack PDU phase. The number of entries is contained in the ePDULoadDevNumPhases OID. | |||||||||||||||||||||
| RePDULoadPhaseConfigEntry | 1.3.6.1.4.1.3808.1.1.3.2.2.1.1 | NA | mandatory | ||||||||||||||||||
| CePDULoadPhaseConfigIndex | 1.3.6.1.4.1.3808.1.1.3.2.2.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The index to the Rack PDU phase entry.
| |||||||||||||||||||||
| CePDULoadPhaseConfigLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.3.2.2.1.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the ePDULoadPhaseConfigNearOverloadThreshold OID. | |||||||||||||||||||||
| CePDULoadPhaseConfigNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.3.2.2.1.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the ePDULoadPhaseConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the ePDULoadPhaseConfigOverloadThreshold OID. | |||||||||||||||||||||
| CePDULoadPhaseConfigOverloadThreshold | 1.3.6.1.4.1.3808.1.1.3.2.2.1.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the ePDULoadPhaseConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the ePDULoadDevMaxPhaseLoad OID. | |||||||||||||||||||||
| CePDULoadPhaseConfigAlarm | 1.3.6.1.4.1.3808.1.1.3.2.2.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the current Phase Alarm.
| |||||||||||||||||||||
| NePDULoadStatus | 1.3.6.1.4.1.3808.1.1.3.2.3 | ||||||||||||||||||||
| TePDULoadStatusTable | 1.3.6.1.4.1.3808.1.1.3.2.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of status of each Rack PDU phase/bank. The number of entries is calculated by adding the number of phases (ePDULoadDevNumPhases OID) and the number of banks of outlets (ePDULoadDevNumBanks) Number of entries = #phases + #banks. NOTE: If a device has phase and bank information, all phase information shall precede the bank information. | |||||||||||||||||||||
| RePDULoadStatusEntry | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The Rack PDU phase/bank to gather status from.
| |||||||||||||||||||||
| CePDULoadStatusIndex | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to the Rack PDU phase/bank entry. All phase information will precede any bank information | |||||||||||||||||||||
| CePDULoadStatusLoad | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.2 | Gauge | RO | mandatory | 11 | ||||||||||||||||
column · Gauge · read-only · mandatory Getting this OID will return the phase/bank load measured in tenths of Amps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CePDULoadStatusLoadState | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase/bank load state. loadNormal(1) indicates that the phase/bank is operating properly within the ePDULoadConfigLowLoadThreshold and ePDULoadConfigNearOverloadThreshold OID values. loadLow(2) indicates that the phase/bank load has dropped below the ePDULoadConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. loadNearOverload(3) indicates that the phase/bank load is greater than or equal to the ePDULoadConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. loadOverload(4) indicates that the phase/bank load is greater than or equal to the ePDULoadConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
| |||||||||||||||||||||
| CePDULoadStatusPhaseNumber | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The phase number to which this record refers. | |||||||||||||||||||||
| CePDULoadStatusBankNumber | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The bank number to which this record refers. A value of 0 will be returned if any bank is not present or if it is phase related. | |||||||||||||||||||||
| CePDULoadStatusVoltage | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.6 | INTEGER | RO | mandatory | 2290 | ||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase/bank voltage measured in 0.1 volts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CePDULoadStatusActivePower | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.7 | INTEGER | RO | mandatory | 500 | ||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase/bank active power measured in watts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CePDULoadStatusApparentPower | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase/bank apparent power measured in VA. | |||||||||||||||||||||
| CePDULoadStatusPowerFactor | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return power factor of the output measured in hundredths. A value of 100 representing a unity power factor (1.00). | |||||||||||||||||||||
| CePDULoadStatusEnergy | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase/bank apparent power measured in 0.1 kilowatt-hours. | |||||||||||||||||||||
| CePDULoadStatusEnergyStartTime | 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Getting this OID will return the date and time of the last energy meter reset | |||||||||||||||||||||
| NePDULoadBankConfig | 1.3.6.1.4.1.3808.1.1.3.2.4 | ||||||||||||||||||||
| TePDULoadBankConfigTable | 1.3.6.1.4.1.3808.1.1.3.2.4.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for configuration of each Rack PDU bank. The number of entries is contained in the ePDULoadDevNumBanks OID. | |||||||||||||||||||||
| RePDULoadBankConfigEntry | 1.3.6.1.4.1.3808.1.1.3.2.4.1.1 | NA | mandatory | ||||||||||||||||||
| CePDULoadBankConfigIndex | 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to the Rack PDU bank entry. | |||||||||||||||||||||
| CePDULoadBankConfigLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. Maximum value must be less than the value returned by the ePDULoadBankConfigNearOverloadThreshold OID. | |||||||||||||||||||||
| CePDULoadBankConfigNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the ePDULoadBankConfigLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the ePDULoadBankConfigOverloadThreshold OID. | |||||||||||||||||||||
| CePDULoadBankConfigOverloadThreshold | 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the ePDULoadBankConfigNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the ePDULoadDevMaxBankLoad OID. | |||||||||||||||||||||
| CePDULoadBankConfigAlarm | 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the current Bank Alarm.
| |||||||||||||||||||||
| NePDUOutlet | 1.3.6.1.4.1.3808.1.1.3.3 | ||||||||||||||||||||
| NePDUOutletDevice | 1.3.6.1.4.1.3808.1.1.3.3.1 | ||||||||||||||||||||
| SePDUOutletDevCommand | 1.3.6.1.4.1.3808.1.1.3.3.1.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this OID to immediateAllOn (2) will turn all outlets on immediately. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will reboot all outlets immediately. Setting this OID to delayedAllOn (5) will turn all outlets on as defined by each outlet's ePDUOutletConfigPowerOnTime OID value. Setting this OID to delayedAllOff (6) will turn all outlets off as defined by each outlet's ePDUOutletConfigPowerOffTime OID value. Setting this OID to delayedAllReboot (7) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest ePDUOutletConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack PDU to be canceled. Getting this OID will return the noCommandAll (1) value.
| |||||||||||||||||||||
| SePDUOutletDevColdstartDelay | 1.3.6.1.4.1.3808.1.1.3.3.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The amount of delay, in seconds, between when power is provided to the Switched Rack PDU and when the Switched Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes). | |||||||||||||||||||||
| SePDUOutletDevNumCntrlOutlets | 1.3.6.1.4.1.3808.1.1.3.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of controlled outlets on this Switched Rack PDU. | |||||||||||||||||||||
| SePDUOutletDevNumTotalOutlets | 1.3.6.1.4.1.3808.1.1.3.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The total number of outlets on this Rack PDU. | |||||||||||||||||||||
| SePDUOutletDevMonitoredOutlets | 1.3.6.1.4.1.3808.1.1.3.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The total number of monitored outlets on this Rack PDU. | |||||||||||||||||||||
| SePDUOutletDevColdstartState | 1.3.6.1.4.1.3808.1.1.3.3.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The ePDU outlet state after coldstart. Allowed values are: 1 - all outlets on after coldstart. 2 - outlet status same as previous state.
| |||||||||||||||||||||
| NePDUOutletPhase | 1.3.6.1.4.1.3808.1.1.3.3.2 | ||||||||||||||||||||
| TePDUOutletPhaseTable | 1.3.6.1.4.1.3808.1.1.3.3.2.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for management of outlets on a per phase basis. | |||||||||||||||||||||
| RePDUOutletPhaseEntry | 1.3.6.1.4.1.3808.1.1.3.3.2.1.1 | NA | mandatory | ||||||||||||||||||
| CePDUOutletPhaseIndex | 1.3.6.1.4.1.3808.1.1.3.3.2.1.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The index to the Switched Rack PDU phase entry.
| |||||||||||||||||||||
| CePDUOutletPhaseOverloadRestriction | 1.3.6.1.4.1.3808.1.1.3.3.2.1.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the ePDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the ePDULoadConfigOverloadThreshold OID is exceeded.
| |||||||||||||||||||||
| NePDUOutletControl | 1.3.6.1.4.1.3808.1.1.3.3.3 | ||||||||||||||||||||
| TePDUOutletControlTable | 1.3.6.1.4.1.3808.1.1.3.3.3.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for control of the individual outlets. The number of entries is contained in the ePDUOutletDevNumCntrlOutlets OID. | |||||||||||||||||||||
| RePDUOutletControlEntry | 1.3.6.1.4.1.3808.1.1.3.3.3.1.1 | NA | mandatory | ||||||||||||||||||
| CePDUOutletControlIndex | 1.3.6.1.4.1.3808.1.1.3.3.3.1.1.1 | INTEGER (1..24) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..24) · read-only · mandatory The index to the outlet entry. | |||||||||||||||||||||
| CePDUOutletControlOutletName | 1.3.6.1.4.1.3808.1.1.3.3.3.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. This OID is provided for informational purposes only. | |||||||||||||||||||||
| CePDUOutletControlOutletPhase | 1.3.6.1.4.1.3808.1.1.3.3.3.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
| |||||||||||||||||||||
| CePDUOutletControlOutletCommand | 1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will immediately reboot the outlet. Setting this variable to delayedOn (4) will turn the outlet on after the ePDUOutletConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (5) will turn the outlet off after the ePDUOutletConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched Rack PDU to perform a delayedOff command, wait the ePDUOutletConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (7) will cause any pending command to this outlet to be canceled. Setting this variable to outletIdentify (8) will cause PDU LED to display the number of the outlet.
| |||||||||||||||||||||
| CePDUOutletControlOutletBank | 1.3.6.1.4.1.3808.1.1.3.3.3.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The bank associated with this outlet. | |||||||||||||||||||||
| NePDUOutletConfig | 1.3.6.1.4.1.3808.1.1.3.3.4 | ||||||||||||||||||||
| TePDUOutletConfigTable | 1.3.6.1.4.1.3808.1.1.3.3.4.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for configuration of individual outlets. The number of entries is contained in the ePDUOutletDevNumCntrlOutlets OID. | |||||||||||||||||||||
| RePDUOutletConfigEntry | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1 | NA | mandatory | ||||||||||||||||||
| CePDUOutletConfigIndex | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1.1 | INTEGER (1..24) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..24) · read-only · mandatory The index to the outlet entry. | |||||||||||||||||||||
| CePDUOutletConfigOutletName | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1.2 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. | |||||||||||||||||||||
| CePDUOutletConfigOutletPhase | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
| |||||||||||||||||||||
| CePDUOutletConfigPowerOnTime | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay
powering on at coldstart or when a command that requires
a turn-on delay is issued.
Allowed values are:
-1 - never power on.
0 - power on immediately.
1 to 7200 - power on up to 7200 seconds after being
commanded. | |||||||||||||||||||||
| CePDUOutletConfigPowerOffTime | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay
powering off when a command that requires
a turn-off delay is issued.
Allowed values are:
-1 - never power off.
0 - power off immediately.
1 to 7200 - power off up to 7200 seconds after being
commanded. | |||||||||||||||||||||
| CePDUOutletConfigRebootDuration | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute). | |||||||||||||||||||||
| CePDUOutletConfigOutletBank | 1.3.6.1.4.1.3808.1.1.3.3.4.1.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The bank associated with this outlet. | |||||||||||||||||||||
| SePDUOutletConfigMonitoredTableSize | 1.3.6.1.4.1.3808.1.1.3.3.4.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Outlet Config Monitored Table | |||||||||||||||||||||
| TePDUOutletConfigMonitoredTable | 1.3.6.1.4.1.3808.1.1.3.3.4.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU. | |||||||||||||||||||||
| RePDUOutletConfigMonitoredEntry | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory This gives access to Monitored Outlet entries | |||||||||||||||||||||
| CePDUOutletConfigMonitoredIndex | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.1 | INTEGER (1..24) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..24) · read-only · mandatory The index to the RACK PDU Phase entry. | |||||||||||||||||||||
| CePDUOutletConfigMonitoredName | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.2 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The name of the Monitored Outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. | |||||||||||||||||||||
| CePDUOutletConfigMonitoredNumber | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The outlet number of an Outlet Monitored RACK PDU. | |||||||||||||||||||||
| CePDUOutletConfigMonitoredLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in watts. A warning will be issued when the load is less than the threshold value. A threshold value of 0 effectively disables this warning. Maximum value must be less than the value returned by the ePDUOutletConfigMonitoredNearOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU. | |||||||||||||||||||||
| CePDUOutletConfigMonitoredNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in watts. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than the value returned by the ePDUOutletConfigMonitoredLowLoadThreshold OID. Maximum value must be less than or equal to the value returned by the ePDUOutletConfigMonitoredOverloadThreshold OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU. | |||||||||||||||||||||
| CePDUOutletConfigMonitoredOverloadThreshold | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in watts. A warning will be issued when the load is greater than or equal to the threshold value. Minimum value must be greater than or equal to the value returned by the ePDUOutletConfigMonitoredNearOverloadThreshold OID. Maximum value must be less than or equal to the value returned by the ePDULoadDevMaxOutletLoad OID. 0 will be returned if the unit is not Outlet Monitored Rack PDU. | |||||||||||||||||||||
| CePDUOutletConfigMonitoredPeakLoadReset | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the existing peak power value to be replaced by the current load power value. Getting this oid will do nothing and return noAction (1) if the PDU support this feature, return notSupport (3) if the PDU do not support this feature.
| |||||||||||||||||||||
| CePDUOutletConfigMonitoredEnergyReset | 1.3.6.1.4.1.3808.1.1.3.3.4.3.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the device energy meter value to be reset to zero. Getting this oid will do nothing and return noAction (1) if the PDU support this feature, return notSupport (3) if the PDU do not support this feature.
| |||||||||||||||||||||
| NePDUOutletStatus | 1.3.6.1.4.1.3808.1.1.3.3.5 | ||||||||||||||||||||
| TePDUOutletStatusTable | 1.3.6.1.4.1.3808.1.1.3.3.5.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of status of individual outlets. The number of entries is contained in the ePDUOutletDevNumCntrlOutlets OID. | |||||||||||||||||||||
| RePDUOutletStatusEntry | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1 | NA | mandatory | ||||||||||||||||||
| CePDUOutletStatusIndex | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.1 | INTEGER (1..24) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..24) · read-only · mandatory The index to the outlet entry. | |||||||||||||||||||||
| CePDUOutletStatusOutletName | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The name of the outlet. The maximum string size is device dependent. This OID is provided for informational purposes only. | |||||||||||||||||||||
| CePDUOutletStatusOutletPhase | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
| |||||||||||||||||||||
| CePDUOutletStatusOutletState | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this variable will return the outlet state. If the outlet is on, the outletStatusOn (1) value will be returned. If the outlet is off, the outletStatusOff (2) value will be returned.
| |||||||||||||||||||||
| CePDUOutletStatusCommandPending | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned.
| |||||||||||||||||||||
| CePDUOutletStatusOutletBank | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The bank associated with this outlet. | |||||||||||||||||||||
| CePDUOutletStatusLoad | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.7 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in tenths of Amps. | |||||||||||||||||||||
| CePDUOutletStatusActivePower | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.8 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in watts | |||||||||||||||||||||
| CePDUOutletStatusAlarm | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the current outlet alarm
| |||||||||||||||||||||
| CePDUOutletStatusPeakPower | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.10 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The peak power consumption of the Rack PDU load in watts. This value can be reset by setting the oid ePDUOutletConfigMonitoredPeakLoadReset to reset (2) | |||||||||||||||||||||
| CePDUOutletStatusPeakPowerTime | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Get this oid shows the date and time that peak power consumption occurred | |||||||||||||||||||||
| CePDUOutletStatusPeakPowerStart | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Get this oid shows the date and time that peak power consumption started | |||||||||||||||||||||
| CePDUOutletStatusEnergy | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.13 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours. This value can be reset by setting the oid ePDUOutletConfigMonitoredEnergyReset to reset (2) | |||||||||||||||||||||
| CePDUOutletStatusEnergyStartTime | 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.14 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time of the last device energy meter reset | |||||||||||||||||||||
| NePDUOutletBank | 1.3.6.1.4.1.3808.1.1.3.3.6 | ||||||||||||||||||||
| TePDUOutletBankTable | 1.3.6.1.4.1.3808.1.1.3.3.6.1 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for management of outlets on a per bank basis. | |||||||||||||||||||||
| RePDUOutletBankEntry | 1.3.6.1.4.1.3808.1.1.3.3.6.1.1 | NA | mandatory | ||||||||||||||||||
| CePDUOutletBankIndex | 1.3.6.1.4.1.3808.1.1.3.3.6.1.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to the Switched Rack PDU bank entry. | |||||||||||||||||||||
| CePDUOutletBankOverloadRestriction | 1.3.6.1.4.1.3808.1.1.3.3.6.1.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the ePDULoadBankConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the ePDULoadBankConfigOverloadThreshold OID is exceeded.
| |||||||||||||||||||||
| NePDUPowerSupply | 1.3.6.1.4.1.3808.1.1.3.4 | ||||||||||||||||||||
| NePDUPowerSupplyDevice | 1.3.6.1.4.1.3808.1.1.3.4.1 | ||||||||||||||||||||
| SePDUPowerSupply1Status | 1.3.6.1.4.1.3808.1.1.3.4.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return powerSupply1Ok(1) if power supply 1 is functioning normally. If not functioning normally, this OID will return powerSupply1Failed(2).
| |||||||||||||||||||||
| SePDUPowerSupply2Status | 1.3.6.1.4.1.3808.1.1.3.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return powerSupply2Ok(1) if power supply 2 is functioning normally. If not functioning normally, this OID will return powerSupply2Failed(2). Metered Rack PDUs do not have a redundant powersupply.
| |||||||||||||||||||||
| SePDUPowerSupplyAlarm | 1.3.6.1.4.1.3808.1.1.3.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return powerSupply Alarm
| |||||||||||||||||||||
| NePDUStatus | 1.3.6.1.4.1.3808.1.1.3.5 | ||||||||||||||||||||
| SePDUStatusBankTableSize | 1.3.6.1.4.1.3808.1.1.3.5.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Status Bank Table | |||||||||||||||||||||
| TePDUStatusBankTable | 1.3.6.1.4.1.3808.1.1.3.5.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of status of each Rack PDU Bank | |||||||||||||||||||||
| RePDUStatusBankEntry | 1.3.6.1.4.1.3808.1.1.3.5.2.1 | NA | mandatory | ||||||||||||||||||
| CePDUStatusBankIndex | 1.3.6.1.4.1.3808.1.1.3.5.2.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to the RACK PDU Bank entry. | |||||||||||||||||||||
| CePDUStatusBankNumber | 1.3.6.1.4.1.3808.1.1.3.5.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bank number. | |||||||||||||||||||||
| CePDUStatusBankState | 1.3.6.1.4.1.3808.1.1.3.5.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bank load state. bankLoadNormal(1) indicates that the bank is operating properly within the ePDULoadBankConfigLowLoadThreshold and ePDULoadBankConfigNearOverloadThreshold OID values. bankLoadLow(2) indicates that the bank load has dropped below the ePDULoadBankConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadNearOverload(3) indicates that the bank load is greater than or equal to the ePDULoadBankConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. bankLoadOverload(4) indicates that the bank load is greater than or equal to the ePDULoadBankConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
| |||||||||||||||||||||
| SePDUStatusPhaseTableSize | 1.3.6.1.4.1.3808.1.1.3.5.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Status Phase Table | |||||||||||||||||||||
| TePDUStatusPhaseTable | 1.3.6.1.4.1.3808.1.1.3.5.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of status of each Rack PDU Phase | |||||||||||||||||||||
| RePDUStatusPhaseEntry | 1.3.6.1.4.1.3808.1.1.3.5.4.1 | NA | mandatory | ||||||||||||||||||
| CePDUStatusPhaseIndex | 1.3.6.1.4.1.3808.1.1.3.5.4.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to the RACK PDU Phase entry. | |||||||||||||||||||||
| CePDUStatusPhaseNumber | 1.3.6.1.4.1.3808.1.1.3.5.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase number. | |||||||||||||||||||||
| CePDUStatusPhaseState | 1.3.6.1.4.1.3808.1.1.3.5.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the Phase load state. phaseLoadNormal(1) indicates that the Phase is operating properly within the ePDULoadPhaseConfigLowLoadThreshold and ePDULoadPhaseConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the Phase load has dropped below the ePDULoadPhaseConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the Phase load is greater than or equal to the ePDULoadPhaseConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the Phase load is greater than or equal to the ePDULoadPhaseConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
| |||||||||||||||||||||
| SePDUStatusOutletTableSize | 1.3.6.1.4.1.3808.1.1.3.5.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Status Outlet Table | |||||||||||||||||||||
| TePDUStatusOutletTable | 1.3.6.1.4.1.3808.1.1.3.5.6 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU. | |||||||||||||||||||||
| RePDUStatusOutletEntry | 1.3.6.1.4.1.3808.1.1.3.5.6.1 | NA | mandatory | ||||||||||||||||||
| CePDUStatusOutletIndex | 1.3.6.1.4.1.3808.1.1.3.5.6.1.1 | INTEGER (1..24) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..24) · read-only · mandatory The index to the RACK PDU Outlet entry. | |||||||||||||||||||||
| CePDUStatusOutletNumber | 1.3.6.1.4.1.3808.1.1.3.5.6.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the Outlet number. | |||||||||||||||||||||
| CePDUStatusOutletState | 1.3.6.1.4.1.3808.1.1.3.5.6.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the Outlet load state. outletLoadNormal(1) indicates that the Outlet is operating properly within the ePDUOutletConfigMonitoredLowLoadThreshold and ePDUOutletConfigMonitoredNearOverloadThreshold OID values. outletLoadLow(2) indicates that the Outlet load has dropped below the ePDUOutletConfigMonitoredLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadNearOverload(3) indicates that the Outlet load is greater than or equal to the ePDUOutletConfigMonitoredNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. outletLoadOverload(4) indicates that the Outlet load is greater than or equal to the ePDUOutletConfigMonitoredOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared.
| |||||||||||||||||||||
| SePDUStatusInputVoltage | 1.3.6.1.4.1.3808.1.1.3.5.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The input voltage in 0.1 Volt. | |||||||||||||||||||||
| SePDUStatusInputFrequency | 1.3.6.1.4.1.3808.1.1.3.5.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The input frequency in 0.1 Hertz. | |||||||||||||||||||||
| NenvironmentSensor | 1.3.6.1.4.1.3808.1.1.4 | ||||||||||||||||||||
| NenvirIdent | 1.3.6.1.4.1.3808.1.1.4.1 | ||||||||||||||||||||
| SenvirIdentName | 1.3.6.1.4.1.3808.1.1.4.1.1 | DisplayString | RW | mandatory | EnvSensor | ||||||||||||||||
scalar · DisplayString · read-write · mandatory The name of the environment sensor. The maximum string size is device dependent. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirIdentLocation | 1.3.6.1.4.1.3808.1.1.4.1.2 | DisplayString | RW | mandatory | Server Room | ||||||||||||||||
scalar · DisplayString · read-write · mandatory The location of the environment sensor. The maximum string size is device dependent. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NenvirTemp | 1.3.6.1.4.1.3808.1.1.4.2 | ||||||||||||||||||||
| SenvirTemperature | 1.3.6.1.4.1.3808.1.1.4.2.1 | INTEGER | RO | mandatory | 683 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The environment temperature expressed in 1/10 Fahrenheit Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempHighThreshold | 1.3.6.1.4.1.3808.1.1.4.2.2 | INTEGER | RW | mandatory | 90 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The high temperature threshold of the environment sensor. The value expressed in Fahrenheit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempLowThreshold | 1.3.6.1.4.1.3808.1.1.4.2.3 | INTEGER | RW | mandatory | 59 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The low temperature threshold of the environment sensor. The value expressed in Fahrenheit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempRateOfChange | 1.3.6.1.4.1.3808.1.1.4.2.4 | INTEGER | RW | mandatory | 18 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The rate of change of the temperature. The value expressed in Fahrenheit per 5 minute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempHysteresis | 1.3.6.1.4.1.3808.1.1.4.2.5 | INTEGER | RW | mandatory | 4 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in Fahrenheit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTemperatureCelsius | 1.3.6.1.4.1.3808.1.1.4.2.6 | INTEGER | RO | mandatory | | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The environment temperature expressed in 1/10 Celsius Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempCelsiusHighThreshold | 1.3.6.1.4.1.3808.1.1.4.2.7 | INTEGER | RW | mandatory | 32 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The high temperature threshold of the environment sensor. The value expressed in Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempCelsiusLowThreshold | 1.3.6.1.4.1.3808.1.1.4.2.8 | INTEGER | RW | mandatory | 15 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The low temperature threshold of the environment sensor. The value expressed in Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempCelsiusRateOfChange | 1.3.6.1.4.1.3808.1.1.4.2.9 | INTEGER | RW | mandatory | 10 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The rate of change of the temperature. The value expressed in Celsius per 5 minute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirTempCelsiusHysteresis | 1.3.6.1.4.1.3808.1.1.4.2.10 | INTEGER | RW | mandatory | 2 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NenvirHumid | 1.3.6.1.4.1.3808.1.1.4.3 | ||||||||||||||||||||
| SenvirHumidity | 1.3.6.1.4.1.3808.1.1.4.3.1 | INTEGER | RO | mandatory | 56 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The environment relative humidity expressed in persentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirHumidHighThreshold | 1.3.6.1.4.1.3808.1.1.4.3.2 | INTEGER | RW | mandatory | 80 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The high relative humidity threshold of the environment sensor. The value expressed in persentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirHumidLowThreshold | 1.3.6.1.4.1.3808.1.1.4.3.3 | INTEGER | RW | mandatory | 20 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The low relative humidity threshold of the environment sensor. The value expressed in persentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirHumidRateOfChange | 1.3.6.1.4.1.3808.1.1.4.3.4 | INTEGER | RW | mandatory | 20 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The rate of change of the relative humidity. The value expressed in persentage per 5 minute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SenvirHumidHysteresis | 1.3.6.1.4.1.3808.1.1.4.3.5 | INTEGER | RW | mandatory | 5 | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The number of degrees beyond the relative humidity thresholds at which an active relative humidity alarm will be cleared. This configuration setting applies to all relative humidity thresholds. Units are displayed in persentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NenvirContact | 1.3.6.1.4.1.3808.1.1.4.4 | ||||||||||||||||||||
| SenvirContactTableSize | 1.3.6.1.4.1.3808.1.1.4.4.1 | INTEGER | RO | mandatory | 4 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of the contact in the environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TenvirContactTable | 1.3.6.1.4.1.3808.1.1.4.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of information of each contact of the environment sensor. | |||||||||||||||||||||
| RenvirContactEntry | 1.3.6.1.4.1.3808.1.1.4.4.2.1 | NA | mandatory | ||||||||||||||||||
| CenvirContactIndex | 1.3.6.1.4.1.3808.1.1.4.4.2.1.1 | INTEGER (1..4) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the contact of the environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CenvirContactName | 1.3.6.1.4.1.3808.1.1.4.4.2.1.2 | DisplayString | RW | mandatory | Door Alarm | ||||||||||||||||
column · DisplayString · read-write · mandatory Getting or setting the name of the contact of the environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CenvirContactStatus | 1.3.6.1.4.1.3808.1.1.4.4.2.1.3 | INTEGER | RO | mandatory | contactNormal(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the Contact Status.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CenvirContactNormalState | 1.3.6.1.4.1.3808.1.1.4.4.2.1.4 | INTEGER | RW | mandatory | normalOpen(1) | ||||||||||||||||
column · INTEGER · read-write · mandatory Set the contact normal state.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nats | 1.3.6.1.4.1.3808.1.1.5 | ||||||||||||||||||||
| NatsIdent | 1.3.6.1.4.1.3808.1.1.5.1 | ||||||||||||||||||||
| SatsIdentName | 1.3.6.1.4.1.3808.1.1.5.1.1 | DisplayString | RW | mandatory | |||||||||||||||||
scalar · DisplayString · read-write · mandatory The name of the ATS. The maximum string size is device dependent. | |||||||||||||||||||||
| SatsIdentModelName | 1.3.6.1.4.1.3808.1.1.5.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifying the model name of the Automatic Transfer Switch. This value is set at the factory. | |||||||||||||||||||||
| SatsIdentHardwareRev | 1.3.6.1.4.1.3808.1.1.5.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The hardware revision of the Automatic Transfer Switch. This value is set at the factory. | |||||||||||||||||||||
| SatsIdentFirmwareRev | 1.3.6.1.4.1.3808.1.1.5.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifying the Automatic Transfer Switch firmware revision. | |||||||||||||||||||||
| SatsIdentSerialNumber | 1.3.6.1.4.1.3808.1.1.5.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifying the serial number of the Automatic Transfer Switch. This value is set at the factory. | |||||||||||||||||||||
| SatsIdentDateOfManufacture | 1.3.6.1.4.1.3808.1.1.5.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format. This value is set at the factory. | |||||||||||||||||||||
| SatsIdentDeviceRatingVoltage | 1.3.6.1.4.1.3808.1.1.5.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifing the Automatic Transfer Switch rating voltage. | |||||||||||||||||||||
| SatsIdentDeviceRatingCurrent | 1.3.6.1.4.1.3808.1.1.5.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This gives the device rating current in Amps | |||||||||||||||||||||
| SatsIdentDeviceOutletNum | 1.3.6.1.4.1.3808.1.1.5.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This gives the outlet number of the device | |||||||||||||||||||||
| SatsIdentAgentModelName | 1.3.6.1.4.1.3808.1.1.5.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifying the model name of the Agent. | |||||||||||||||||||||
| SatsIdentAgentHardwareRevision | 1.3.6.1.4.1.3808.1.1.5.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The hardware revision of the Agent. | |||||||||||||||||||||
| SatsIdentAgentFirmwareRevision | 1.3.6.1.4.1.3808.1.1.5.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifying the Agent firmware revision. | |||||||||||||||||||||
| SatsIdentAgentSerialNumber | 1.3.6.1.4.1.3808.1.1.5.1.13 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A string identifying the serial number of the Agent. | |||||||||||||||||||||
| NatsStatus | 1.3.6.1.4.1.3808.1.1.5.2 | ||||||||||||||||||||
| NatsStatusDevice | 1.3.6.1.4.1.3808.1.1.5.2.1 | ||||||||||||||||||||
| SatsStatusCommStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the current communication status between the Automatic Transfer Switch and the Agent.
| |||||||||||||||||||||
| SatsStatusSelectedSource | 1.3.6.1.4.1.3808.1.1.5.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the current source of power.
| |||||||||||||||||||||
| SatsStatusRedundancyState | 1.3.6.1.4.1.3808.1.1.5.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the current redundancy state of the ATS. atsRedundancyLost(1) indicates that the ATS is unable to switch over to the alternate power source if the current source fails. atsFullyRedundant(2) indicates that the ATS will switch over to the alternate power source if the current source fails.
| |||||||||||||||||||||
| SatsStatusPhaseSyncStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the status of the phase sync.
| |||||||||||||||||||||
| SatsStatusDevSourceRelayStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the status of the source relay.
| |||||||||||||||||||||
| SatsStatusDevInRelayStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the status of the input relay.
| |||||||||||||||||||||
| SatsStatusDevOutRelayStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the status of the Output relay.
| |||||||||||||||||||||
| SatsStatusDevLCDCommStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the communication status of the LCD.
| |||||||||||||||||||||
| SatsStatusDevDB9CommStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This variable returns the communication status of the DB9.
| |||||||||||||||||||||
| TatsStatusPowerSupplyTable | 1.3.6.1.4.1.3808.1.1.5.2.1.10 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of power supply table entries. | |||||||||||||||||||||
| RatsStatusPowerSupplyEntry | 1.3.6.1.4.1.3808.1.1.5.2.1.10.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry containing power supply information applicable to a particular input. | |||||||||||||||||||||
| CatsStatusPowerSupplyTableIndex | 1.3.6.1.4.1.3808.1.1.5.2.1.10.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The input identifier. | |||||||||||||||||||||
| CatsStatusPowerSupplyInputSource | 1.3.6.1.4.1.3808.1.1.5.2.1.10.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input source to the power supply.
| |||||||||||||||||||||
| CatsStatusPowerSupply12VStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.10.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the status of the power supply A 12V in system.
| |||||||||||||||||||||
| CatsStatusPowerSupply5VStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.10.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the status of the power supply A 5V in system.
| |||||||||||||||||||||
| CatsStatusPowerSupply3p3VStatus | 1.3.6.1.4.1.3808.1.1.5.2.1.10.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the status of the power supply A 3.3V in system.
| |||||||||||||||||||||
| NatsStatusInput | 1.3.6.1.4.1.3808.1.1.5.2.2 | ||||||||||||||||||||
| SatsStatusInputNum | 1.3.6.1.4.1.3808.1.1.5.2.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of input feeds to this device. This variable indicates the number of rows in the status input table. | |||||||||||||||||||||
| TatsStatusInputTable | 1.3.6.1.4.1.3808.1.1.5.2.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of input table entries. The number of entries is given by the value of atsNumInputs. | |||||||||||||||||||||
| RatsStatusInputEntry | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular input. | |||||||||||||||||||||
| CatsStatusInputTableIndex | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The input identifier. | |||||||||||||||||||||
| CatsStatusInputName | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.2 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory A name given to a particular input. | |||||||||||||||||||||
| CatsStatusNumInputPhase | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of input phases utilized in this device. The sum of all the atsStatusNumInputPhase variable indicates the number of rows in the status input phase table. | |||||||||||||||||||||
| CatsStatusInputVoltageOrientation | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage orientation: 1: unknown for this Source 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 1 and Phase 2. 4: threePhasePhaseToNeutral - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 and Neutral; phase 3 voltage is between Phase 3 and Neutral. 5: threePhasePhaseToPhase - phase 1 voltage is between Phase 1 and Phase 2; phase 2 voltage is between Phase 2 and Phase 3; phase 3 voltage is between Phase 3 and Phase 1.
| |||||||||||||||||||||
| CatsStatusInputVoltage | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage in 0.1 Volt. | |||||||||||||||||||||
| CatsStatusInputFrequency | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input frequency in 0.1 Hertz. | |||||||||||||||||||||
| CatsStatusInputVolState | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage status.
| |||||||||||||||||||||
| CatsStatusInputFreqState | 1.3.6.1.4.1.3808.1.1.5.2.2.2.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input frequency status.
| |||||||||||||||||||||
| TatsStatusInputPhaseTable | 1.3.6.1.4.1.3808.1.1.5.2.2.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of input table entries. The number of entries is given by the sum of the atsNumInputPhases. | |||||||||||||||||||||
| RatsStatusInputPhaseEntry | 1.3.6.1.4.1.3808.1.1.5.2.2.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory An entry containing information applicable to a particular input phase. | |||||||||||||||||||||
| CatsStatusInputPhaseTableIndex | 1.3.6.1.4.1.3808.1.1.5.2.2.3.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The input identifier. | |||||||||||||||||||||
| CatsStatusInputPhaseIndex | 1.3.6.1.4.1.3808.1.1.5.2.2.3.1.2 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The input phase identifier. | |||||||||||||||||||||
| CatsStatusInputPhaseVoltage | 1.3.6.1.4.1.3808.1.1.5.2.2.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage in VAC, or -1 if it's unsupported by this Source. | |||||||||||||||||||||
| CatsStatusInputPhaseCurrent | 1.3.6.1.4.1.3808.1.1.5.2.2.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input current in amperes, or -1 if it's unsupported by this Source. | |||||||||||||||||||||
| CatsStatusInputPhasePower | 1.3.6.1.4.1.3808.1.1.5.2.2.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input power in Watts, or -1 if it's unsupported by this Source. | |||||||||||||||||||||
| NatsConfig | 1.3.6.1.4.1.3808.1.1.5.3 | ||||||||||||||||||||
| SatsConfigPreferredSource | 1.3.6.1.4.1.3808.1.1.5.3.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory This variable returns the preferred source of power when both sources are OK.
| |||||||||||||||||||||
| SatsConfigNominalVoltage | 1.3.6.1.4.1.3808.1.1.5.3.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory This variable returns the nominal voltage of the input. | |||||||||||||||||||||
| SatsConfigVoltageSensitivity | 1.3.6.1.4.1.3808.1.1.5.3.3 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory This variable defines the sensitivity to changes in voltage: high(1) for best protection, low(3) for frequent small line voltage changes.
| |||||||||||||||||||||
| SatsConfigTransferVoltageRange | 1.3.6.1.4.1.3808.1.1.5.3.4 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory This variable defines the range of acceptable voltage from a power source. If the voltage measured from the selected input source is not within this range, the Automatic Transfer Switch will switch over (transfer) to the alternate power source.
| |||||||||||||||||||||
| SatsConfigNarrowRangeValue | 1.3.6.1.4.1.3808.1.1.5.3.5 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory To configure the Narrow Range value of acceptable voltage from a power source. | |||||||||||||||||||||
| SatsConfigMediumRangeValue | 1.3.6.1.4.1.3808.1.1.5.3.6 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory To configure the Medium Range value of acceptable voltage from a power source. | |||||||||||||||||||||
| SatsConfigWideRangeValue | 1.3.6.1.4.1.3808.1.1.5.3.7 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory To configure the Wide Range value of acceptable voltage from a power source. | |||||||||||||||||||||
| SatsConfigFrequencyDeviation | 1.3.6.1.4.1.3808.1.1.5.3.8 | INTEGER (1..3) | RW | mandatory | |||||||||||||||||
scalar · INTEGER (1..3) · read-write · mandatory To configure the frequency deviation. | |||||||||||||||||||||
| SatsConfigDevLCDOffTime | 1.3.6.1.4.1.3808.1.1.5.3.9 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The amount of time (in seconds) which LCD turn off automatically after it remains idle for. | |||||||||||||||||||||
| NatsControl | 1.3.6.1.4.1.3808.1.1.5.4 | ||||||||||||||||||||
| SatsCtrlResetATS | 1.3.6.1.4.1.3808.1.1.5.4.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this variable will cause the Automatic Transfer Switch to reboot or reset relative setting to default value.
| |||||||||||||||||||||
| SatsCtrlClearEventCounts | 1.3.6.1.4.1.3808.1.1.5.4.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this variable will clear all event counts in Automatic Transfer Switch. Returns (-1) if unsupported.
| |||||||||||||||||||||
| NatsLoad | 1.3.6.1.4.1.3808.1.1.5.5 | ||||||||||||||||||||
| NatsLoadDevice | 1.3.6.1.4.1.3808.1.1.5.5.1 | ||||||||||||||||||||
| SatsLoadDevPhaseTableSize | 1.3.6.1.4.1.3808.1.1.5.5.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Phase Table. | |||||||||||||||||||||
| TatsLoadDevPhaseTable | 1.3.6.1.4.1.3808.1.1.5.5.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Phase Max Load in the ATS. | |||||||||||||||||||||
| RatsLoadDevPhaseEntry | 1.3.6.1.4.1.3808.1.1.5.5.1.2.1 | NA | mandatory | ||||||||||||||||||
| CatsLoadDevPhaseTableIndex | 1.3.6.1.4.1.3808.1.1.5.5.1.2.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to ATS phase entry. | |||||||||||||||||||||
| CatsLoadDevPhase | 1.3.6.1.4.1.3808.1.1.5.5.1.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
| |||||||||||||||||||||
| CatsLoadDevPhaseMaxLoad | 1.3.6.1.4.1.3808.1.1.5.5.1.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the maximum rated power that each phase of the ATS can provide. It is represented in Amps. | |||||||||||||||||||||
| SatsLoadDevBankTableSize | 1.3.6.1.4.1.3808.1.1.5.5.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Bank Table. | |||||||||||||||||||||
| TatsLoadDevBankTable | 1.3.6.1.4.1.3808.1.1.5.5.1.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Bank Max Load in the ATS. | |||||||||||||||||||||
| RatsLoadDevBankEntry | 1.3.6.1.4.1.3808.1.1.5.5.1.4.1 | NA | mandatory | ||||||||||||||||||
| CatsLoadDevBankTableIndex | 1.3.6.1.4.1.3808.1.1.5.5.1.4.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The index to the ATS bank entry.
| |||||||||||||||||||||
| CatsLoadDevBankMaxLoad | 1.3.6.1.4.1.3808.1.1.5.5.1.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the maximum rated power that each bank of the ATS can provide. It is represented in Amps. | |||||||||||||||||||||
| NatsLoadStatus | 1.3.6.1.4.1.3808.1.1.5.5.2 | ||||||||||||||||||||
| SatsLoadStatusPhaseTableSize | 1.3.6.1.4.1.3808.1.1.5.5.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Phase Table. | |||||||||||||||||||||
| TatsLoadStatusPhaseTable | 1.3.6.1.4.1.3808.1.1.5.5.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Phase Load status in the ATS. | |||||||||||||||||||||
| RatsLoadStatusPhaseEntry | 1.3.6.1.4.1.3808.1.1.5.5.2.2.1 | NA | mandatory | ||||||||||||||||||
| CatsLoadStatusPhaseTableIndex | 1.3.6.1.4.1.3808.1.1.5.5.2.2.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to ATS phase entry. | |||||||||||||||||||||
| CatsLoadStatusPhase | 1.3.6.1.4.1.3808.1.1.5.5.2.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
| |||||||||||||||||||||
| CatsLoadStatusPhaseLoad | 1.3.6.1.4.1.3808.1.1.5.5.2.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The output current in 0.1 amperes drawn by the load on the ATS | |||||||||||||||||||||
| CatsLoadStatusPhaseLoadState | 1.3.6.1.4.1.3808.1.1.5.5.2.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase load state.
| |||||||||||||||||||||
| CatsLoadStatusPhasePower | 1.3.6.1.4.1.3808.1.1.5.5.2.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The output power in Watts. | |||||||||||||||||||||
| SatsLoadStatusBankTableSize | 1.3.6.1.4.1.3808.1.1.5.5.2.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Bank Table. | |||||||||||||||||||||
| TatsLoadStatusBankTable | 1.3.6.1.4.1.3808.1.1.5.5.2.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting the Bank Load status in the ATS. | |||||||||||||||||||||
| RatsLoadStatusBankEntry | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1 | NA | mandatory | ||||||||||||||||||
| CatsLoadStatusBankTableIndex | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The index to ATS bank entry.
| |||||||||||||||||||||
| CatsLoadStatusBankPhase | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase number.
| |||||||||||||||||||||
| CatsLoadStatusBankLoad | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The output current in 0.1 amperes drawn by the load on the ATS | |||||||||||||||||||||
| CatsLoadStatusBankLoadState | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the bank load state.
| |||||||||||||||||||||
| CatsLoadStatusBankPower | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The output power in Watts. | |||||||||||||||||||||
| CatsLoadStatusBankEnergy | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the phase/bank apparent power measured in 0.1 kilowatt-hours. | |||||||||||||||||||||
| CatsLoadStatusBankStartTime | 1.3.6.1.4.1.3808.1.1.5.5.2.4.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the date and time of the last energy meter reset | |||||||||||||||||||||
| NatsLoadConfig | 1.3.6.1.4.1.3808.1.1.5.5.3 | ||||||||||||||||||||
| SatsLoadCfgPhaseTableSize | 1.3.6.1.4.1.3808.1.1.5.5.3.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Phase Table. | |||||||||||||||||||||
| TatsLoadCfgPhaseTable | 1.3.6.1.4.1.3808.1.1.5.5.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for configuration of each ATS phase. | |||||||||||||||||||||
| RatsLoadCfgPhaseEntry | 1.3.6.1.4.1.3808.1.1.5.5.3.2.1 | NA | mandatory | ||||||||||||||||||
| CatsLoadCfgPhaseTableIndex | 1.3.6.1.4.1.3808.1.1.5.5.3.2.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The index to the ATS phase entry. | |||||||||||||||||||||
| CatsLoadCfgPhase | 1.3.6.1.4.1.3808.1.1.5.5.3.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
| |||||||||||||||||||||
| CatsLoadCfgPhaseLowLoad | 1.3.6.1.4.1.3808.1.1.5.5.3.2.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. | |||||||||||||||||||||
| CatsLoadCfgPhaseNearOverLoad | 1.3.6.1.4.1.3808.1.1.5.5.3.2.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. | |||||||||||||||||||||
| CatsLoadCfgPhaseOverLoad | 1.3.6.1.4.1.3808.1.1.5.5.3.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. | |||||||||||||||||||||
| CatsLoadCfgPhaseOutletRestriction | 1.3.6.1.4.1.3808.1.1.5.5.3.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This OID controls the behavior of a ATS phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the ePDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the ePDULoadConfigOverloadThreshold OID is exceeded.
| |||||||||||||||||||||
| SatsLoadCfgBankTableSize | 1.3.6.1.4.1.3808.1.1.5.5.3.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the Bank Table. | |||||||||||||||||||||
| TatsLoadCfgBankTable | 1.3.6.1.4.1.3808.1.1.5.5.3.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for configuration of each ATS bank. | |||||||||||||||||||||
| RatsLoadCfgBankEntry | 1.3.6.1.4.1.3808.1.1.5.5.3.4.1 | NA | mandatory | ||||||||||||||||||
| CatsLoadCfgBankTableIndex | 1.3.6.1.4.1.3808.1.1.5.5.3.4.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The index to the ATS bank entry.
| |||||||||||||||||||||
| CatsLoadCfgBankLowLoad | 1.3.6.1.4.1.3808.1.1.5.5.3.4.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value of 0 Amps effectively disables this warning. | |||||||||||||||||||||
| CatsLoadCfgBankNearOverLoad | 1.3.6.1.4.1.3808.1.1.5.5.3.4.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. | |||||||||||||||||||||
| CatsLoadCfgBankOverLoad | 1.3.6.1.4.1.3808.1.1.5.5.3.4.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory A threshold that indicates the power consumption of the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. | |||||||||||||||||||||
| CatsLoadCfgBankOutletRestriction | 1.3.6.1.4.1.3808.1.1.5.5.3.4.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This OID controls the behavior of a ATS phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the ePDULoadConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the ePDULoadConfigOverloadThreshold OID is exceeded.
| |||||||||||||||||||||
| CatsLoadCfgBankEnergyReset | 1.3.6.1.4.1.3808.1.1.5.5.3.4.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the bank energy meter value to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value.
| |||||||||||||||||||||
| NatsOutlet | 1.3.6.1.4.1.3808.1.1.5.6 | ||||||||||||||||||||
| NatsOutletDevice | 1.3.6.1.4.1.3808.1.1.5.6.1 | ||||||||||||||||||||
| SatsOutletDevTotalOutletNum | 1.3.6.1.4.1.3808.1.1.5.6.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The total number of outlets on the ATS. | |||||||||||||||||||||
| SatsOutletDevCtrlOutletNum | 1.3.6.1.4.1.3808.1.1.5.6.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of controlled outlets on the ATS. | |||||||||||||||||||||
| SatsOutletDevColdStartDelay | 1.3.6.1.4.1.3808.1.1.5.6.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The amount of delay, in seconds, between when power is provided to the ATS and when the ATS provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes). | |||||||||||||||||||||
| SatsOutletDevColdStartState | 1.3.6.1.4.1.3808.1.1.5.6.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The ATS outlet state after coldstart. Allowed values are: 1 - all outlets on after coldstart. 2 - outlet status same as previous state.
| |||||||||||||||||||||
| SatsOutletDevLocalCtrl | 1.3.6.1.4.1.3808.1.1.5.6.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory To configure enable or disable outlet local control function.
| |||||||||||||||||||||
| SatsOutletDevCommand | 1.3.6.1.4.1.3808.1.1.5.6.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this OID to immediateAllOn (2) will turn all outlets on immediately. Setting this OID to immediateAllOff (3) will turn all outlets off immediately. Setting this OID to immediateAllReboot (4) will reboot all outlets immediately. Setting this OID to delayedAllOn (5) will turn all outlets on as defined by each outlet's atsOutletCfgPowerOnTime OID value. Setting this OID to delayedAllOff (6) will turn all outlets off as defined by each outlet's atsOutletCfgPowerOffTime OID value. Setting this OID to delayedAllReboot (7) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack ATS will then delay the largest atsOutletCfgRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to cancelAllPendingCommands (8) will cause all pending commands on the Switched Rack ATS to be canceled. Getting this OID will return the noCommandAll (1) value.
| |||||||||||||||||||||
| SatsOutletStatusTableSize | 1.3.6.1.4.1.3808.1.1.5.6.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the outlet status table. | |||||||||||||||||||||
| TatsOutletStatusTable | 1.3.6.1.4.1.3808.1.1.5.6.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of status of individual outlets. | |||||||||||||||||||||
| RatsOutletStatusEntry | 1.3.6.1.4.1.3808.1.1.5.6.3.1 | NA | mandatory | ||||||||||||||||||
| CatsOutletStatusTableIndex | 1.3.6.1.4.1.3808.1.1.5.6.3.1.1 | INTEGER (1..19) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..19) · read-only · mandatory The index to the outlet entry. | |||||||||||||||||||||
| CatsOutletStatusOutletName | 1.3.6.1.4.1.3808.1.1.5.6.3.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The name of the outlet. The maximum string size is device dependent. This OID is provided for informational purposes only. | |||||||||||||||||||||
| CatsOutletStatusOutletState | 1.3.6.1.4.1.3808.1.1.5.6.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this variable will return the outlet state. If the outlet is on, the outletStatusOn (1) value will be returned. If the outlet is off, the outletStatusOff (2) value will be returned.
| |||||||||||||||||||||
| CatsOutletStatusOutletCmdPending | 1.3.6.1.4.1.3808.1.1.5.6.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned.
| |||||||||||||||||||||
| CatsOutletStatusOutletPhase | 1.3.6.1.4.1.3808.1.1.5.6.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The phase/s associated with this outlet. For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (3) for outlets tied to a single phase. For outlets tied to two phases, this object will return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for phases 2 and 3, and phase3-1 (6) for phases 3 and 1.
| |||||||||||||||||||||
| CatsOutletStatusOutletBank | 1.3.6.1.4.1.3808.1.1.5.6.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The bank associated with this outlet. | |||||||||||||||||||||
| SatsOutletCtrlTableSize | 1.3.6.1.4.1.3808.1.1.5.6.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the outlet control table. | |||||||||||||||||||||
| TatsOutletCtrlTable | 1.3.6.1.4.1.3808.1.1.5.6.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for control of the individual outlets. | |||||||||||||||||||||
| RatsOutletCtrlEntry | 1.3.6.1.4.1.3808.1.1.5.6.5.1 | NA | mandatory | ||||||||||||||||||
| CatsOutletCtrlTableIndex | 1.3.6.1.4.1.3808.1.1.5.6.5.1.1 | INTEGER (1..19) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..19) · read-only · mandatory The index to the outlet entry. | |||||||||||||||||||||
| CatsOutletCtrlOutletName | 1.3.6.1.4.1.3808.1.1.5.6.5.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. This OID is provided for informational purposes only. | |||||||||||||||||||||
| CatsOutletCtrlCommand | 1.3.6.1.4.1.3808.1.1.5.6.5.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Getting this variable will return the outlet state. If the outlet is on, the immediateOn (2) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setting this variable to immediateOn (2) will immediately turn the outlet on. Setting this variable to immediateOff (3) will immediately turn the outlet off. Setting this variable to immediateReboot (4) will immediately reboot the outlet. Setting this variable to delayedOn (5) will turn the outlet on after the ePDUOutletConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (6) will turn the outlet off after the ePDUOutletConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (7) will cause the ATS to perform a delayedOff command, wait the atsOutletCfgRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (8) will cause any pending command to this outlet to be canceled.
| |||||||||||||||||||||
| SatsOutletCfgTableSize | 1.3.6.1.4.1.3808.1.1.5.6.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the outlet config table. | |||||||||||||||||||||
| TatsOutletCfgTable | 1.3.6.1.4.1.3808.1.1.5.6.7 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for configuration of individual outlets. | |||||||||||||||||||||
| RatsOutletCfgEntry | 1.3.6.1.4.1.3808.1.1.5.6.7.1 | NA | mandatory | ||||||||||||||||||
| CatsOutletCfgTableIndex | 1.3.6.1.4.1.3808.1.1.5.6.7.1.1 | INTEGER (1..19) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..19) · read-only · mandatory The index to the outlet entry. | |||||||||||||||||||||
| CatsOutletCfgOutletName | 1.3.6.1.4.1.3808.1.1.5.6.7.1.2 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The name of the outlet. The maximum string size is device dependent. An error will be returned if the set request exceeds the max size. | |||||||||||||||||||||
| CatsOutletCfgPowerOnTime | 1.3.6.1.4.1.3808.1.1.5.6.7.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 - never power on. 0 - power on immediately. 1 to 7200 - power on up to 7200 seconds after being commanded. | |||||||||||||||||||||
| CatsOutletCfgPowerOffTime | 1.3.6.1.4.1.3808.1.1.5.6.7.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never power off. 0 - power off immediately. 1 to 7200 - power off up to 7200 seconds after being commanded. | |||||||||||||||||||||
| CatsOutletCfgRebootDuration | 1.3.6.1.4.1.3808.1.1.5.6.7.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute). | |||||||||||||||||||||
| NePDU2 | 1.3.6.1.4.1.3808.1.1.6 | ||||||||||||||||||||
| SePDU2Role | 1.3.6.1.4.1.3808.1.1.6.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get this oid shows the role the PDU played on Daisy Chain Group. The PDU as a Host can access whole ePDU2 content, and the PDU be standalong or a Slave can access itself instead.
| |||||||||||||||||||||
| NePDU2Ident | 1.3.6.1.4.1.3808.1.1.6.2 | ||||||||||||||||||||
| SePDU2IdentTableSize | 1.3.6.1.4.1.3808.1.1.6.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory PDU as a Host response total PDU ident number on daisy chain. PDU as a Slave can only response 1. | |||||||||||||||||||||
| TePDU2IdentTable | 1.3.6.1.4.1.3808.1.1.6.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU identification information. | |||||||||||||||||||||
| RePDU2IdentEntry | 1.3.6.1.4.1.3808.1.1.6.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Identification data from Rack PDU being queried.
| |||||||||||||||||||||
| CePDU2IdentIndex | 1.3.6.1.4.1.3808.1.1.6.2.2.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Rack PDU identification table entry. | |||||||||||||||||||||
| CePDU2IdentModuleIndex | 1.3.6.1.4.1.3808.1.1.6.2.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU identification table entry numeric ID. | |||||||||||||||||||||
| CePDU2IdentName | 1.3.6.1.4.1.3808.1.1.6.2.2.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A user-defined string identifying the name of the Rack PDU. | |||||||||||||||||||||
| CePDU2IdentLocation | 1.3.6.1.4.1.3808.1.1.6.2.2.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A user-defined string identifying the location of the Rack PDU. | |||||||||||||||||||||
| CePDU2IdentContact | 1.3.6.1.4.1.3808.1.1.6.2.2.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A user-defined string identifying the person to contact of the Rack PDU. | |||||||||||||||||||||
| CePDU2IdentHardwareRev | 1.3.6.1.4.1.3808.1.1.6.2.2.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Rack PDU hardware version. | |||||||||||||||||||||
| CePDU2IdentFirmwareRev | 1.3.6.1.4.1.3808.1.1.6.2.2.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Rack PDU firmware version. | |||||||||||||||||||||
| CePDU2IdentDateOfManufacture | 1.3.6.1.4.1.3808.1.1.6.2.2.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The date the Rack PDU was manufactured in mm/dd/yyyy format. | |||||||||||||||||||||
| CePDU2IdentModelName | 1.3.6.1.4.1.3808.1.1.6.2.2.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Rack PDU model number. | |||||||||||||||||||||
| CePDU2IdentSerialNumber | 1.3.6.1.4.1.3808.1.1.6.2.2.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The Rack PDU serial number. | |||||||||||||||||||||
| CePDU2IdentIndicator | 1.3.6.1.4.1.3808.1.1.6.2.2.1.11 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory PDU will perform a panel indicator test when the variable is set to testIndicators(2). It is no effective to set this value to noTestIndicators(1).
| |||||||||||||||||||||
| NePDU2Device | 1.3.6.1.4.1.3808.1.1.6.3 | ||||||||||||||||||||
| SePDU2DeviceTableSize | 1.3.6.1.4.1.3808.1.1.6.3.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A Host Rack PDU response total number of Rack PDUs on daisy chain. Rack PDU as a Slave can only response 1. | |||||||||||||||||||||
| TePDU2DeviceConfigTable | 1.3.6.1.4.1.3808.1.1.6.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU configuration data. | |||||||||||||||||||||
| RePDU2DeviceConfigEntry | 1.3.6.1.4.1.3808.1.1.6.3.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from Rack PDU being queried. | |||||||||||||||||||||
| CePDU2DeviceConfigIndex | 1.3.6.1.4.1.3808.1.1.6.3.2.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Rack PDU table entry. | |||||||||||||||||||||
| CePDU2DeviceConfigModuleIndex | 1.3.6.1.4.1.3808.1.1.6.3.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2DeviceConfigName | 1.3.6.1.4.1.3808.1.1.6.3.2.1.3 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory A user-defined string identifying the name of Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceConfigLocation | 1.3.6.1.4.1.3808.1.1.6.3.2.1.4 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory A user-defined string identifying the location of the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceConfigContact | 1.3.6.1.4.1.3808.1.1.6.3.2.1.5 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory A user-defined string identifying the person to contact of the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceConfigDisplayOrientation | 1.3.6.1.4.1.3808.1.1.6.3.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Getting this OID will return the intended physical orientation of the Seven-Segment Display. displayNormal(1) indicates Normal. displayReverse(2)indicates Upside-Down. displayRotate90(3) indicates rotate 90 degree. displayRotate270(4) indicates rotate 270 degree. displayAuto(5) indicates auto-detect and rotate.
| |||||||||||||||||||||
| CePDU2DeviceConfigColdstartDelay | 1.3.6.1.4.1.3808.1.1.6.3.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. 0 - apply power immediately. 1 to 300 - delay up to 300 seconds (5 minutes). | |||||||||||||||||||||
| CePDU2DeviceConfigCurrentLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.6.3.2.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined low current draw alarm threshold, measured in Amps. | |||||||||||||||||||||
| CePDU2DeviceConfigCurrentNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.3.2.1.9 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined near overload current threshold, measured in Amps. | |||||||||||||||||||||
| CePDU2DeviceConfigCurrentOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.3.2.1.10 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined current overload threshold, measured in Amps. | |||||||||||||||||||||
| CePDU2DeviceConfigPeakLoadReset | 1.3.6.1.4.1.3808.1.1.6.3.2.1.11 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to resetAll (2) will cause the existing peak current value of Rack PDU and its outlets to be replaced by the current load current value. Setting this OID to resetDevice (3) to reset the Rack PDU only. Setting this OID to resetOutlets (4) to reset the PDU outlets only. Getting this OID will do nothing and return the noOperation(1) value.
| |||||||||||||||||||||
| CePDU2DeviceConfigEnergyReset | 1.3.6.1.4.1.3808.1.1.6.3.2.1.12 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to resetAll (2) will cause the device energy meter value to be reset to zero. Setting this OID to resetDevice (3) to reset the Rack PDU only. Setting this OID to resetOutlets (4) to reset the PDU outlets only. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value.
| |||||||||||||||||||||
| CePDU2DeviceConfigPowerLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.6.3.2.1.13 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined low power draw alarm threshold, measured in Watts. | |||||||||||||||||||||
| CePDU2DeviceConfigPowerNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.3.2.1.14 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined near overload power threshold, measured in Watts. | |||||||||||||||||||||
| CePDU2DeviceConfigPowerOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.3.2.1.15 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined power overload threshold, measured in Watts. | |||||||||||||||||||||
| TePDU2DeviceInfoTable | 1.3.6.1.4.1.3808.1.1.6.3.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU information. | |||||||||||||||||||||
| RePDU2DeviceInfoEntry | 1.3.6.1.4.1.3808.1.1.6.3.3.1 | NA | mandatory | ||||||||||||||||||
| CePDU2DeviceInfoIndex | 1.3.6.1.4.1.3808.1.1.6.3.3.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Rack PDU Information table entry. | |||||||||||||||||||||
| CePDU2DeviceInfoModuleIndex | 1.3.6.1.4.1.3808.1.1.6.3.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2DeviceInfoName | 1.3.6.1.4.1.3808.1.1.6.3.3.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A user-defined string identifying the name of the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceInfoRating | 1.3.6.1.4.1.3808.1.1.6.3.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The electrical rating of the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceInfoNumOutlets | 1.3.6.1.4.1.3808.1.1.6.3.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of outlets on the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceInfoSwitchedOutlets | 1.3.6.1.4.1.3808.1.1.6.3.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of switched outlets on the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceInfoMeteredOutlets | 1.3.6.1.4.1.3808.1.1.6.3.3.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of metered outlets on the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceInfoNumPhases | 1.3.6.1.4.1.3808.1.1.6.3.3.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of phases present in the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceInfoNumBreakers | 1.3.6.1.4.1.3808.1.1.6.3.3.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The number of metered banks present in the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceInfoBreakerRating | 1.3.6.1.4.1.3808.1.1.6.3.3.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The maximum current rating, measured in Amps, for the Rack PDU. Getting this OID will return rating of the circuit breakers on the device if it has any. | |||||||||||||||||||||
| CePDU2DeviceInfoOrientation | 1.3.6.1.4.1.3808.1.1.6.3.3.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Rack PDU orientation.
| |||||||||||||||||||||
| CePDU2DeviceInfoOutletLayout | 1.3.6.1.4.1.3808.1.1.6.3.3.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return outlet layout for the device. SeqPhaseToNeutral(1) indicates outlet layout as follows: Outlet(1-5 and 16-20):1-N, outlet(6-10 and 21-25):2-N, outlet(11-15 and 26-30):3-N,4:1-N,5:2-N, or for single phase SKUs, all outlets 1-N. SeqPhaseToPhase(2) indicates outlet layout as follows: Outlet(1-5 and 16-20):1-2, outlet(6-10 and 21-25):2-3, outlet(11-15 and 26-30):3-1. SeqOther(3) indicates outlet layout as follows: TBD
| |||||||||||||||||||||
| CePDU2DeviceInfoPowerLimit | 1.3.6.1.4.1.3808.1.1.6.3.3.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The maximum power limit, measured in Watt, for the Rack PDU. | |||||||||||||||||||||
| TePDU2DeviceStatusTable | 1.3.6.1.4.1.3808.1.1.6.3.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU current status. | |||||||||||||||||||||
| RePDU2DeviceStatusEntry | 1.3.6.1.4.1.3808.1.1.6.3.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status data from the Rack PDU being queried. | |||||||||||||||||||||
| CePDU2DeviceStatusIndex | 1.3.6.1.4.1.3808.1.1.6.3.4.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Rack PDU status table entry. | |||||||||||||||||||||
| CePDU2DeviceStatusModuleIndex | 1.3.6.1.4.1.3808.1.1.6.3.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID | |||||||||||||||||||||
| CePDU2DeviceStatusName | 1.3.6.1.4.1.3808.1.1.6.3.4.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A user-defined string identifying the name of the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceStatusLoadState | 1.3.6.1.4.1.3808.1.1.6.3.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the present load status of the Rack PDU.
| |||||||||||||||||||||
| CePDU2DeviceStatusCurrentLoad | 1.3.6.1.4.1.3808.1.1.6.3.4.1.5 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The power consumption of the Rack PDU load in tenths of Amps. | |||||||||||||||||||||
| CePDU2DeviceStatusCurrentPeakLoad | 1.3.6.1.4.1.3808.1.1.6.3.4.1.6 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The peak power consumption of the Rack PDU load in tenths of Amps. | |||||||||||||||||||||
| CePDU2DeviceStatusPeakLoadTimestamp | 1.3.6.1.4.1.3808.1.1.6.3.4.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time that peak load occurred. | |||||||||||||||||||||
| CePDU2DeviceStatusPeakLoadStartTime | 1.3.6.1.4.1.3808.1.1.6.3.4.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time of the last device peak load reset. | |||||||||||||||||||||
| CePDU2DeviceStatusEnergy | 1.3.6.1.4.1.3808.1.1.6.3.4.1.9 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory A user resettable energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours. | |||||||||||||||||||||
| CePDU2DeviceStatusEnergyStartTime | 1.3.6.1.4.1.3808.1.1.6.3.4.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time of the last device energy meter reset. | |||||||||||||||||||||
| CePDU2DeviceStatusCommandPending | 1.3.6.1.4.1.3808.1.1.6.3.4.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether or not the device is processing a pending command.
| |||||||||||||||||||||
| CePDU2DeviceStatusPowerSupplyAlarm | 1.3.6.1.4.1.3808.1.1.6.3.4.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates a power supply alarm is active when value equals alarm (2).
| |||||||||||||||||||||
| CePDU2DeviceStatusPowerSupply1Status | 1.3.6.1.4.1.3808.1.1.6.3.4.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether or not an alarm is active in Power Supply 1.
| |||||||||||||||||||||
| CePDU2DeviceStatusPowerSupply2Status | 1.3.6.1.4.1.3808.1.1.6.3.4.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates whether or not an alarm is active in Power Supply 2.
| |||||||||||||||||||||
| CePDU2DeviceStatusApparentPower | 1.3.6.1.4.1.3808.1.1.6.3.4.1.15 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The apparent power consumption of the Rack PDU load in VoltAmps (VA). | |||||||||||||||||||||
| CePDU2DeviceStatusPowerFactor | 1.3.6.1.4.1.3808.1.1.6.3.4.1.16 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The power factor of the Rack PDU load in hundredths. | |||||||||||||||||||||
| CePDU2DeviceStatusRoleType | 1.3.6.1.4.1.3808.1.1.6.3.4.1.17 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Get this oid shows the role the PDU played on Daisy Chain Group. The PDU as a Host can access whole ePDU2 content, and the PDU be standalong or a Slave can access itself instead.
| |||||||||||||||||||||
| CePDU2DeviceStatusPowerLoad | 1.3.6.1.4.1.3808.1.1.6.3.4.1.18 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The power consumption of the Rack PDU load in Watts. | |||||||||||||||||||||
| CePDU2DeviceStatusPowerPeakLoad | 1.3.6.1.4.1.3808.1.1.6.3.4.1.19 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The peak power consumption of the Rack PDU load in Watts. | |||||||||||||||||||||
| TePDU2DeviceControlTable | 1.3.6.1.4.1.3808.1.1.6.3.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU control data. | |||||||||||||||||||||
| RePDU2DeviceControlEntry | 1.3.6.1.4.1.3808.1.1.6.3.5.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Control data from Rack PDU being queried. | |||||||||||||||||||||
| CePDU2DeviceControlIndex | 1.3.6.1.4.1.3808.1.1.6.3.5.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Rack PDU control table entry. | |||||||||||||||||||||
| CePDU2DeviceControlModuleIndex | 1.3.6.1.4.1.3808.1.1.6.3.5.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2DeviceControlName | 1.3.6.1.4.1.3808.1.1.6.3.5.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory A user-defined string identifying the name of the Rack PDU. | |||||||||||||||||||||
| CePDU2DeviceControlCommand | 1.3.6.1.4.1.3808.1.1.6.3.5.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to immediateAllOn (1) will turn all outlets on immediately. Setting this OID to immediateAllOff (2) will turn all outlets off immediately. Setting this OID to immediateAllReboot (3) will cause an immediateAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the ePDU2OutletSwitchedConfigRebootDuration OID time, and then perform an immediateAllOn command. Setting this OID to delayedAllOn (4) will turn all outlets on as defined by each outlet's ePDU2OutletSwitchedConfigPowerOnTime OID value. Setting this OID to delayedAllOff (5) will turn all outlets off as defined by each outlet's ePDU2OutletSwitchedConfigPowerOffTime OID value. Setting this OID to delayedAllReboot (6) will cause a delayedAllOff command to be performed. Once all outlets are off, the Switched Rack PDU will then delay the largest ePDU2OutletSwitchedConfigRebootDuration OID time, and then perform a delayedAllOn command. Setting this OID to cancelAllPendingCommand (7) will cause all pending commands on the Switched Rack PDU to be cancelled. Setting this OID to noCommand (8) will have no effect. Getting this OID will return the noCommand (8) value.
| |||||||||||||||||||||
| NePDU2Phase | 1.3.6.1.4.1.3808.1.1.6.4 | ||||||||||||||||||||
| SePDU2PhaseTableSize | 1.3.6.1.4.1.3808.1.1.6.4.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A Host Rack PDU response total phase number of Rack PDUs on daisy chain. Rack PDU as a Slave can only response itself number of phase. | |||||||||||||||||||||
| TePDU2PhaseConfigTable | 1.3.6.1.4.1.3808.1.1.6.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU phase configuration data. | |||||||||||||||||||||
| RePDU2PhaseConfigEntry | 1.3.6.1.4.1.3808.1.1.6.4.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from currently queried Rack PDU phase. | |||||||||||||||||||||
| CePDU2PhaseConfigIndex | 1.3.6.1.4.1.3808.1.1.6.4.2.1.1 | INTEGER (1..12) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..12) · read-only · mandatory The index to the Rack PDU phase configuration table entry. | |||||||||||||||||||||
| CePDU2PhaseConfigModuleIndex | 1.3.6.1.4.1.3808.1.1.6.4.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2PhaseConfigNumber | 1.3.6.1.4.1.3808.1.1.6.4.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric phase ID. | |||||||||||||||||||||
| CePDU2PhaseConfigOverloadRestriction | 1.3.6.1.4.1.3808.1.1.6.4.2.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This OID controls the behavior of a Switched Rack PDU phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding phase to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding phase to turn on if the ePDU2PhaseConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding phase to turn on if the ePDU2PhaseConfigOverloadThreshold OID is exceeded. Models that do not support this feature will respond to this OID with a value of notSupported (-1). Attempts to set this OID in these models will fail.
| |||||||||||||||||||||
| CePDU2PhaseConfigLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.6.4.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined low load phase current threshold in Amps. | |||||||||||||||||||||
| CePDU2PhaseConfigNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.4.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined near phase overload current warning threshold in Amps. | |||||||||||||||||||||
| CePDU2PhaseConfigOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.4.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined phase overload current threshold in Amps | |||||||||||||||||||||
| CePDU2PhaseConfigPhasePeakLoadReset | 1.3.6.1.4.1.3808.1.1.6.4.2.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value.
| |||||||||||||||||||||
| TePDU2PhaseInfoTable | 1.3.6.1.4.1.3808.1.1.6.4.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU phase information. | |||||||||||||||||||||
| RePDU2PhaseInfoEntry | 1.3.6.1.4.1.3808.1.1.6.4.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Information data from currently queried Rack PDU phase.
| |||||||||||||||||||||
| CePDU2PhaseInfoIndex | 1.3.6.1.4.1.3808.1.1.6.4.3.1.1 | INTEGER (1..12) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..12) · read-only · mandatory The index to the Rack PDU phase properties table entry. | |||||||||||||||||||||
| CePDU2PhaseInfoModuleIndex | 1.3.6.1.4.1.3808.1.1.6.4.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2PhaseInfoNumber | 1.3.6.1.4.1.3808.1.1.6.4.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric phase ID. | |||||||||||||||||||||
| TePDU2PhaseStatusTable | 1.3.6.1.4.1.3808.1.1.6.4.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU phase status data | |||||||||||||||||||||
| RePDU2PhaseStatusEntry | 1.3.6.1.4.1.3808.1.1.6.4.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status data from currently queried Rack PDU phase | |||||||||||||||||||||
| CePDU2PhaseStatusIndex | 1.3.6.1.4.1.3808.1.1.6.4.4.1.1 | INTEGER (1..12) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..12) · read-only · mandatory The index to the Rack PDU phase status table entry. | |||||||||||||||||||||
| CePDU2PhaseStatusModuleIndex | 1.3.6.1.4.1.3808.1.1.6.4.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2PhaseStatusNumber | 1.3.6.1.4.1.3808.1.1.6.4.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric phase ID. | |||||||||||||||||||||
| CePDU2PhaseStatusLoadState | 1.3.6.1.4.1.3808.1.1.6.4.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the present load status of the Rack PDU phase being queried.
| |||||||||||||||||||||
| CePDU2PhaseStatusLoad | 1.3.6.1.4.1.3808.1.1.6.4.4.1.5 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Indicates the current draw, in tenths of Amps, of the load on the Rack PDU phase being queried. | |||||||||||||||||||||
| CePDU2PhaseStatusVoltage | 1.3.6.1.4.1.3808.1.1.6.4.4.1.6 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Indicates the Voltage, in tenths of Volts, of the Rack PDU phase being queried. | |||||||||||||||||||||
| CePDU2PhaseStatusPower | 1.3.6.1.4.1.3808.1.1.6.4.4.1.7 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Indicates the load power, in watts, consumed on the Rack PDU phase being queried | |||||||||||||||||||||
| CePDU2PhaseStatusApparentPower | 1.3.6.1.4.1.3808.1.1.6.4.4.1.8 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Indicates the load apparent power, in VoltAmps (VA), consumed on the Rack PDU phase being queried | |||||||||||||||||||||
| CePDU2PhaseStatusPowerFactor | 1.3.6.1.4.1.3808.1.1.6.4.4.1.9 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Indicates the load power factor, in hundredths, of the Rack PDU phase being queried | |||||||||||||||||||||
| CePDU2PhaseStatusPeakLoad | 1.3.6.1.4.1.3808.1.1.6.4.4.1.10 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The peak current of the Rack PDU phase load in tenths of Amps | |||||||||||||||||||||
| CePDU2PhaseStatusPeakLoadTimestamp | 1.3.6.1.4.1.3808.1.1.6.4.4.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time the phase peak current occurred. | |||||||||||||||||||||
| CePDU2PhaseStatusPeakLoadStartTime | 1.3.6.1.4.1.3808.1.1.6.4.4.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time of the last phase peak current reset. | |||||||||||||||||||||
| CePDU2PhaseStatusLineToLineVoltage | 1.3.6.1.4.1.3808.1.1.6.4.4.1.13 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Indicates the Line to Line Voltage, in tenths of Volts, of the Rack PDU phase being queried | |||||||||||||||||||||
| NePDU2Bank | 1.3.6.1.4.1.3808.1.1.6.5 | ||||||||||||||||||||
| SePDU2BankTableSize | 1.3.6.1.4.1.3808.1.1.6.5.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A Host Rack PDU response total bank number of Rack PDUs on daisy chain. Rack PDU as a Slave can only response itself number of bank. | |||||||||||||||||||||
| TePDU2BankConfigTable | 1.3.6.1.4.1.3808.1.1.6.5.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU bank configuration data. | |||||||||||||||||||||
| RePDU2BankConfigEntry | 1.3.6.1.4.1.3808.1.1.6.5.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from currently queried Rack PDU bank.
| |||||||||||||||||||||
| CePDU2BankConfigIndex | 1.3.6.1.4.1.3808.1.1.6.5.2.1.1 | INTEGER (1..12) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..12) · read-only · mandatory The index to the Rack PDU bank configuration table entry. | |||||||||||||||||||||
| CePDU2BankConfigModuleIndex | 1.3.6.1.4.1.3808.1.1.6.5.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2BankConfigNumber | 1.3.6.1.4.1.3808.1.1.6.5.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric bank ID. | |||||||||||||||||||||
| CePDU2BankConfigOverloadRestriction | 1.3.6.1.4.1.3808.1.1.6.5.2.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This OID controls the behavior of a Switched Rack PDU bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow the outlets on the corresponding bank to turn on. Setting this OID to restrictOnNearOverload (2) will not allow outlets on the corresponding bank to turn on if the ePDU2BankConfigNearOverloadThreshold OID is exceeded. Setting this OID to restrictOnOverload (3) will not allow outlets on the corresponding bank to turn on if the ePDU2BankConfigOverloadThreshold OID is exceeded.
| |||||||||||||||||||||
| CePDU2BankConfigLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.6.5.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined low load bank current threshold in Amps. | |||||||||||||||||||||
| CePDU2BankConfigNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.5.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined near bank overload current warning threshold in Amps. | |||||||||||||||||||||
| CePDU2BankConfigOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.5.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined bank overload current threshold in Amps | |||||||||||||||||||||
| CePDU2BankConfigPeakLoadReset | 1.3.6.1.4.1.3808.1.1.6.5.2.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the existing peak current value to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value.
| |||||||||||||||||||||
| TePDU2BankInfoTable | 1.3.6.1.4.1.3808.1.1.6.5.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU bank information. | |||||||||||||||||||||
| RePDU2BankInfoEntry | 1.3.6.1.4.1.3808.1.1.6.5.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Information data from currently queried Rack PDU bank.
| |||||||||||||||||||||
| CePDU2BankInfoIndex | 1.3.6.1.4.1.3808.1.1.6.5.3.1.1 | INTEGER (1..12) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..12) · read-only · mandatory The index to the Rack PDU bank properties table entry. | |||||||||||||||||||||
| CePDU2BankInfoModuleIndex | 1.3.6.1.4.1.3808.1.1.6.5.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2BankInfoNumber | 1.3.6.1.4.1.3808.1.1.6.5.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric bank ID. | |||||||||||||||||||||
| TePDU2BankStatusTable | 1.3.6.1.4.1.3808.1.1.6.5.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU bank status data | |||||||||||||||||||||
| RePDU2BankStatusEntry | 1.3.6.1.4.1.3808.1.1.6.5.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status data from currently queried Rack PDU bank
| |||||||||||||||||||||
| CePDU2BankStatusIndex | 1.3.6.1.4.1.3808.1.1.6.5.4.1.1 | INTEGER (1..12) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..12) · read-only · mandatory The index to the Rack PDU bank status table entry. | |||||||||||||||||||||
| CePDU2BankStatusModuleIndex | 1.3.6.1.4.1.3808.1.1.6.5.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2BankStatusNumber | 1.3.6.1.4.1.3808.1.1.6.5.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric bank ID. | |||||||||||||||||||||
| CePDU2BankStatusLoadState | 1.3.6.1.4.1.3808.1.1.6.5.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the present load status of the Rack PDU bank being queried.
| |||||||||||||||||||||
| CePDU2BankStatusLoad | 1.3.6.1.4.1.3808.1.1.6.5.4.1.5 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory Indicates the current draw, in tenths of Amps, of the load on the Rack PDU bank being queried. | |||||||||||||||||||||
| CePDU2BankStatusPeakLoad | 1.3.6.1.4.1.3808.1.1.6.5.4.1.6 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The peak current of the Rack PDU bank load in tenths of Amps. | |||||||||||||||||||||
| CePDU2BankStatusPeakLoadTimestamp | 1.3.6.1.4.1.3808.1.1.6.5.4.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time the bank peak current occurred. | |||||||||||||||||||||
| CePDU2BankStatusPeakLoadStartTime | 1.3.6.1.4.1.3808.1.1.6.5.4.1.8 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time of the last bank peak current reset. | |||||||||||||||||||||
| NePDU2Outlet | 1.3.6.1.4.1.3808.1.1.6.6 | ||||||||||||||||||||
| NePDU2OutletSwitched | 1.3.6.1.4.1.3808.1.1.6.6.1 | ||||||||||||||||||||
| SePDU2OutletSwitchedTableSize | 1.3.6.1.4.1.3808.1.1.6.6.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of switched outlets on connected Rack PDUs. | |||||||||||||||||||||
| TePDU2OutletSwitchedConfigTable | 1.3.6.1.4.1.3808.1.1.6.6.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU switched outlet configuration data. | |||||||||||||||||||||
| RePDU2OutletSwitchedConfigEntry | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from currently queried Rack PDU switched outlet. | |||||||||||||||||||||
| CePDU2OutletSwitchedConfigIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU switched outlet configuration table entry. | |||||||||||||||||||||
| CePDU2OutletSwitchedConfigModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedConfigNumber | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric switched outlet ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedConfigName | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1.4 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The user-defined switched outlet name string. | |||||||||||||||||||||
| CePDU2OutletSwitchedConfigPowerOnTime | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 - never power on. 0 - power on immediately. 1 to 7200 - power on up to 7200 seconds after being commanded. | |||||||||||||||||||||
| CePDU2OutletSwitchedConfigPowerOffTime | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory The amount of time (in seconds) the outlet will delay powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never power off. 0 - power off immediately. 1 to 7200 - power off up to 7200 seconds after being commanded. | |||||||||||||||||||||
| CePDU2OutletSwitchedConfigRebootDuration | 1.3.6.1.4.1.3808.1.1.6.6.1.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory During a reboot sequence, power is turned off and then back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the end of the reboot sequence. Allowed range is any value between 5 and 60 seconds (1 minute). | |||||||||||||||||||||
| TePDU2OutletSwitchedInfoTable | 1.3.6.1.4.1.3808.1.1.6.6.1.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU switched outlet information. | |||||||||||||||||||||
| RePDU2OutletSwitchedInfoEntry | 1.3.6.1.4.1.3808.1.1.6.6.1.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Information of the currently queried Rack PDU switched outlet. | |||||||||||||||||||||
| CePDU2OutletSwitchedInfoIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU switched outlet information table entry. | |||||||||||||||||||||
| CePDU2OutletSwitchedInfoModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedInfoNumber | 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric switched outlet ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedInfoName | 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The numeric switched outlet name. | |||||||||||||||||||||
| CePDU2OutletSwitchedInfoPhaseLayout | 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1. | |||||||||||||||||||||
| CePDU2OutletSwitchedInfoBank | 1.3.6.1.4.1.3808.1.1.6.6.1.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric bank ID. | |||||||||||||||||||||
| TePDU2OutletSwitchedStatusTable | 1.3.6.1.4.1.3808.1.1.6.6.1.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU switched outlet status information. | |||||||||||||||||||||
| RePDU2OutletSwitchedStatusEntry | 1.3.6.1.4.1.3808.1.1.6.6.1.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status information for currently queried Rack PDU switched outlet. | |||||||||||||||||||||
| CePDU2OutletSwitchedStatusIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU switched outlet status information table entry. | |||||||||||||||||||||
| CePDU2OutletSwitchedStatusModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedStatusNumber | 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric switched outlet ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedStatusName | 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined switched outlet name string. | |||||||||||||||||||||
| CePDU2OutletSwitchedStatusState | 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.5 | INTEGER | RO | mandatory | outletStatusOn(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Indicates the present switch state of the Rack PDU switched outlet being queried.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CePDU2OutletSwitchedStatusCommandPending | 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned.
| |||||||||||||||||||||
| TePDU2OutletSwitchedControlTable | 1.3.6.1.4.1.3808.1.1.6.6.1.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU switched outlet control data. | |||||||||||||||||||||
| RePDU2OutletSwitchedControlEntry | 1.3.6.1.4.1.3808.1.1.6.6.1.5.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Control data for currently queried Rack PDU switched outlet. | |||||||||||||||||||||
| CePDU2OutletSwitchedControlIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.5.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU switched outlet control data table entry. | |||||||||||||||||||||
| CePDU2OutletSwitchedControlModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.1.5.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The user-defined Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedControlNumber | 1.3.6.1.4.1.3808.1.1.6.6.1.5.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric switched outlet ID. | |||||||||||||||||||||
| CePDU2OutletSwitchedControlName | 1.3.6.1.4.1.3808.1.1.6.6.1.5.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined switched outlet name string. | |||||||||||||||||||||
| CePDU2OutletSwitchedControlCommand | 1.3.6.1.4.1.3808.1.1.6.6.1.5.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Getting this variable will return the outlet state. If the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setting this variable to immediateOn (1) will immediately turn the outlet on. Setting this variable to immediateOff (2) will immediately turn the outlet off. Setting this variable to immediateReboot (3) will immediately reboot the outlet. Setting this variable to delayedOn (4) will turn the outlet on after the ePDUOutletConfigPowerOnTime OID time has elapsed. Setting this variable to delayedOff (5) will turn the outlet off after the ePDUOutletConfigPowerOffTime OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched Rack PDU to perform a delayedOff command, wait the ePDUOutletConfigRebootDuration OID time, and then perform a delayedOn command. Setting this variable to cancelPendingCommand (7) will cause any pending command to this outlet to be canceled. Setting this variable to outletIdentify (8) will cause PDU LED to display the number of the outlet.
| |||||||||||||||||||||
| NePDU2OutletMetered | 1.3.6.1.4.1.3808.1.1.6.6.2 | ||||||||||||||||||||
| SePDU2OutletMeteredTableSize | 1.3.6.1.4.1.3808.1.1.6.6.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of metered outlets on connected Rack PDUs. | |||||||||||||||||||||
| TePDU2OutletMeteredConfigTable | 1.3.6.1.4.1.3808.1.1.6.6.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU metered outlet configuration data. | |||||||||||||||||||||
| RePDU2OutletMeteredConfigEntry | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from currently queried Rack PDU metered outlet. | |||||||||||||||||||||
| CePDU2OutletMeteredConfigIndex | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU metered outlet configuration table entry. | |||||||||||||||||||||
| CePDU2OutletMeteredConfigModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The user-defined Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletMeteredConfigNumber | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric metered outlet ID. | |||||||||||||||||||||
| CePDU2OutletMeteredConfigName | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.4 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The user-defined metered outlet name string. | |||||||||||||||||||||
| CePDU2OutletMeteredConfigLowLoadThreshold | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined outlet low load current threshold in Watts. | |||||||||||||||||||||
| CePDU2OutletMeteredConfigNearOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined outlet near overload warning threshold in Watts. | |||||||||||||||||||||
| CePDU2OutletMeteredConfigOverloadThreshold | 1.3.6.1.4.1.3808.1.1.6.6.2.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory User-defined outlet overload current threshold in Watts. | |||||||||||||||||||||
| TePDU2OutletMeteredInfoTable | 1.3.6.1.4.1.3808.1.1.6.6.2.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU metered outlet information. | |||||||||||||||||||||
| RePDU2OutletMeteredInfoEntry | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Information of currently queried Rack PDU metered outlet. | |||||||||||||||||||||
| CePDU2OutletMeteredInfoIndex | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU metered information table entry. | |||||||||||||||||||||
| CePDU2OutletMeteredInfoModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletMeteredInfoNumber | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric metered outlet ID. | |||||||||||||||||||||
| CePDU2OutletMeteredInfoName | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined metered outlet name string. | |||||||||||||||||||||
| CePDU2OutletMeteredInfoLayout | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1. | |||||||||||||||||||||
| CePDU2OutletMeteredInfoRating | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Maximum power rating of Rack PDU metered outlet. | |||||||||||||||||||||
| CePDU2OutletMeteredInfoBank | 1.3.6.1.4.1.3808.1.1.6.6.2.3.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This outlet's numeric bank ID. | |||||||||||||||||||||
| TePDU2OutletMeteredStatusTable | 1.3.6.1.4.1.3808.1.1.6.6.2.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU metered outlet status data. | |||||||||||||||||||||
| RePDU2OutletMeteredStatusEntry | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status data from currently queried Rack PDU metered outlet. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusIndex | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU metered status table entry. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusNumber | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric metered outlet ID. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusName | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined metered outlet name string. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusAlarm | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the current outlet alarm.
| |||||||||||||||||||||
| CePDU2OutletMeteredStatusLoad | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.6 | Gauge | RO | mandatory | 0 | ||||||||||||||||
column · Gauge · read-only · mandatory Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in tenths of Amps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CePDU2OutletMeteredStatusActivePower | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.7 | Gauge | RO | mandatory | 0 | ||||||||||||||||
column · Gauge · read-only · mandatory Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU in watts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CePDU2OutletMeteredStatusPeakPower | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.8 | Gauge | RO | mandatory | |||||||||||||||||
column · Gauge · read-only · mandatory The peak power consumption of the Rack PDU load in watts. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusPeakPowerTimestamp | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.9 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Get this oid shows the date and time that peak power consumption occurred. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusPeakPowerStartTime | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.10 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Get this oid shows the date and time that peak power consumption started. | |||||||||||||||||||||
| CePDU2OutletMeteredStatusEnergy | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.11 | Gauge | RO | mandatory | 0 | ||||||||||||||||
column · Gauge · read-only · mandatory Energy meter measuring Rack PDU load energy consumption in tenths of kilowatt-hours. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CePDU2OutletMeteredStatusEnergyStart | 1.3.6.1.4.1.3808.1.1.6.6.2.4.1.12 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Indicates the date and time of the last device energy meter reset. | |||||||||||||||||||||
| NePDU2OutletMonitored | 1.3.6.1.4.1.3808.1.1.6.6.3 | ||||||||||||||||||||
| SePDU2OutletMonitoredTableSize | 1.3.6.1.4.1.3808.1.1.6.6.3.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of monitored outlets on connected Rack PDUs. | |||||||||||||||||||||
| TePDU2OutletMonitoredConfigTable | 1.3.6.1.4.1.3808.1.1.6.6.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU monitored outlet configuration data. | |||||||||||||||||||||
| RePDU2OutletMonitoredConfigEntry | 1.3.6.1.4.1.3808.1.1.6.6.3.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from currently queried Rack PDU monitored outlet. | |||||||||||||||||||||
| CePDU2OutletMonitoredConfigIndex | 1.3.6.1.4.1.3808.1.1.6.6.3.2.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU monitored outlet configuration table entry. | |||||||||||||||||||||
| CePDU2OutletMonitoredConfigModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.3.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The user-defined Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletMonitoredConfigNumber | 1.3.6.1.4.1.3808.1.1.6.6.3.2.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric monitored outlet ID. | |||||||||||||||||||||
| CePDU2OutletMonitoredConfigName | 1.3.6.1.4.1.3808.1.1.6.6.3.2.1.4 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The user-defined monitored outlet name string. | |||||||||||||||||||||
| TePDU2OutletMonitoredInfoTable | 1.3.6.1.4.1.3808.1.1.6.6.3.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU monitored outlet information. | |||||||||||||||||||||
| RePDU2OutletMonitoredInfoEntry | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Information of currently queried Rack PDU monitored outlet. | |||||||||||||||||||||
| CePDU2OutletMonitoredInfoIndex | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU monitored information table entry. | |||||||||||||||||||||
| CePDU2OutletMonitoredInfoModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletMonitoredInfoNumber | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric monitored outlet ID. | |||||||||||||||||||||
| CePDU2OutletMonitoredInfoName | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined monitored outlet name string. | |||||||||||||||||||||
| CePDU2OutletMonitoredInfoLayout | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This OID describes the phase connections of the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that the outlet is wired from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that the outlet is wired from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that the outlet is wired from Phase 1 to Phase 2. seqPhase2ToPhase3(5) indicates that the outlet is wired from Phase 2 to Phase 3. seqPhase3ToPhase1(6) indicates that the outlet is wired from Phase 3 to Phase 1. | |||||||||||||||||||||
| CePDU2OutletMonitoredInfoRating | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Maximum power rating of Rack PDU monitored outlet. | |||||||||||||||||||||
| CePDU2OutletMonitoredInfoBank | 1.3.6.1.4.1.3808.1.1.6.6.3.3.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This outlet's numeric bank ID. | |||||||||||||||||||||
| TePDU2OutletMonitoredStatusTable | 1.3.6.1.4.1.3808.1.1.6.6.3.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Rack PDU monitored outlet status data. | |||||||||||||||||||||
| RePDU2OutletMonitoredStatusEntry | 1.3.6.1.4.1.3808.1.1.6.6.3.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status data from currently queried Rack PDU monitored outlet. | |||||||||||||||||||||
| CePDU2OutletMonitoredStatusIndex | 1.3.6.1.4.1.3808.1.1.6.6.3.4.1.1 | INTEGER (1..96) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..96) · read-only · mandatory The index to the Rack PDU monitored status table entry. | |||||||||||||||||||||
| CePDU2OutletMonitoredStatusModuleIndex | 1.3.6.1.4.1.3808.1.1.6.6.3.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Rack PDU numeric ID. | |||||||||||||||||||||
| CePDU2OutletMonitoredStatusNumber | 1.3.6.1.4.1.3808.1.1.6.6.3.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The numeric monitored outlet ID. | |||||||||||||||||||||
| CePDU2OutletMonitoredStatusName | 1.3.6.1.4.1.3808.1.1.6.6.3.4.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The user-defined monitored outlet name string. | |||||||||||||||||||||
| NePDU2Group | 1.3.6.1.4.1.3808.1.1.6.8 | ||||||||||||||||||||
| SePDU2GroupNumberOfDevices | 1.3.6.1.4.1.3808.1.1.6.8.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Getting this OID will return the number of Rack PDU devices contributing to the Daisy Chain group power and energy values. Queries to slave units in an Daisy Chain group will return 0. | |||||||||||||||||||||
| SePDU2GroupTotalPower | 1.3.6.1.4.1.3808.1.1.6.8.2 | Gauge | RO | mandatory | |||||||||||||||||
scalar · Gauge · read-only · mandatory Getting this OID will return the total power consumption of the Rack PDU Daisy Chain group devices in watts. Queries to slave units in an Daisy Chain group will return 0. | |||||||||||||||||||||
| SePDU2GroupTotalEnergy | 1.3.6.1.4.1.3808.1.1.6.8.3 | Gauge | RO | mandatory | |||||||||||||||||
scalar · Gauge · read-only · mandatory Getting this OID will return the total energy consumption of the Rack PDU Daisy Chain group devices in tenths of kilowatt-hours. To reset the energy meters for each of the Rack PDU devices that contribute to this value, see the ePDU2GroupEnergyReset OID. To view the start time for each of the Rack PDU device energy meters that contribute to this value, see the ePDU2DeviceStatusEnergyStartTime OID. Queries to slave units in an Daisy Chain group will return 0. | |||||||||||||||||||||
| SePDU2GroupEnergyReset | 1.3.6.1.4.1.3808.1.1.6.8.4 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the device energy meter value on each device in the Rack PDU Daisy Chain group to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value.
| |||||||||||||||||||||
| SePDU2GroupPeakRecordReset | 1.3.6.1.4.1.3808.1.1.6.8.5 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this OID to reset (2) will cause the device peak record value on each device in the Rack PDU Daisy Chain group to be reset to current load/power. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value.
| |||||||||||||||||||||
| NePDU2Source | 1.3.6.1.4.1.3808.1.1.6.9 | ||||||||||||||||||||
| SePDU2SourceTableSize | 1.3.6.1.4.1.3808.1.1.6.9.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory A Host Automatic Transfer Switch response total number of Automatic Transfer Switches on daisy chain. Automatic Transfer Switch as a Slave can only response 1. | |||||||||||||||||||||
| TePDU2SourceConfigTable | 1.3.6.1.4.1.3808.1.1.6.9.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Source configuration data. | |||||||||||||||||||||
| RePDU2SourceConfigEntry | 1.3.6.1.4.1.3808.1.1.6.9.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Configuration data from Source being queried. | |||||||||||||||||||||
| CePDU2SourceConfigIndex | 1.3.6.1.4.1.3808.1.1.6.9.2.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Automatic Transfer Switch table entry. | |||||||||||||||||||||
| CePDU2SourceConfigModuleIndex | 1.3.6.1.4.1.3808.1.1.6.9.2.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Automatic Transfer Switch numeric ID. | |||||||||||||||||||||
| CePDU2SourceConfigPreferredSource | 1.3.6.1.4.1.3808.1.1.6.9.2.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This variable returns the preferred source of power when both sources are OK
| |||||||||||||||||||||
| CePDU2SourceConfigFrequencyDeviation | 1.3.6.1.4.1.3808.1.1.6.9.2.1.4 | INTEGER (1..3) | RW | mandatory | |||||||||||||||||
column · INTEGER (1..3) · read-write · mandatory To configure the frequency deviation. | |||||||||||||||||||||
| CePDU2SourceConfigVoltageSensitivity | 1.3.6.1.4.1.3808.1.1.6.9.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This variable defines the sensitivity to changes in voltage: high(1) for best protection, low(3) for frequent small line voltage changes.
| |||||||||||||||||||||
| CePDU2SourceConfigNominalVoltage | 1.3.6.1.4.1.3808.1.1.6.9.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This variable returns the nominal voltage of the input. | |||||||||||||||||||||
| CePDU2SourceConfigTransferVoltageRange | 1.3.6.1.4.1.3808.1.1.6.9.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This variable defines the range of acceptable voltage from a power source. If the voltage measured from the selected input source is not within this range, the Automatic Transfer Switch will switch over (transfer) to the alternate power source.
| |||||||||||||||||||||
| CePDU2SourceConfigNarrowRangeValue | 1.3.6.1.4.1.3808.1.1.6.9.2.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory To configure the Narrow Range value of acceptable voltage from a power source. | |||||||||||||||||||||
| CePDU2SourceConfigMediumRangeValue | 1.3.6.1.4.1.3808.1.1.6.9.2.1.9 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory To configure the Medium Range value of acceptable voltage from a power source. | |||||||||||||||||||||
| CePDU2SourceConfigWideRangeValue | 1.3.6.1.4.1.3808.1.1.6.9.2.1.10 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory To configure the Wide Range value of acceptable voltage from a power source. | |||||||||||||||||||||
| CePDU2EventCountsReset | 1.3.6.1.4.1.3808.1.1.6.9.2.1.11 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Setting this variable will clear all event counts in Automatic Transfer Switch.
| |||||||||||||||||||||
| TePDU2SourceInfoTable | 1.3.6.1.4.1.3808.1.1.6.9.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Automatic Transfer Switch information. | |||||||||||||||||||||
| RePDU2SourceInfoEntry | 1.3.6.1.4.1.3808.1.1.6.9.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Information of the Automatic Transfer Switch being queried.
| |||||||||||||||||||||
| CePDU2SourceInfoIndex | 1.3.6.1.4.1.3808.1.1.6.9.3.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Automatic Transfer Switch Information table entry. | |||||||||||||||||||||
| CePDU2SourceInfoModuleIndex | 1.3.6.1.4.1.3808.1.1.6.9.3.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Automatic Transfer Switch numeric ID. | |||||||||||||||||||||
| CePDU2SourceInfoSourceSwitch | 1.3.6.1.4.1.3808.1.1.6.9.3.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Source Switch event counts of Automatic Transfer Switch. | |||||||||||||||||||||
| CePDU2SourceInfoSourcePreferenceChange | 1.3.6.1.4.1.3808.1.1.6.9.3.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Source Preference Change event counts of Automatic Transfer Switch. | |||||||||||||||||||||
| CePDU2SourceInfoPreferredSourceFreqOutofRange | 1.3.6.1.4.1.3808.1.1.6.9.3.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Preferred Source Frequency Out of Range event counts of Automatic Transfer Switch. | |||||||||||||||||||||
| CePDU2SourceInfoPreferredSourceVoltOutofRange | 1.3.6.1.4.1.3808.1.1.6.9.3.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Preferred Source Voltage Out of Range event counts of Automatic Transfer Switch. | |||||||||||||||||||||
| CePDU2SourceInfoDeviceCurrentOverload | 1.3.6.1.4.1.3808.1.1.6.9.3.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Device Current Overload event counts of Automatic Transfer Switch. | |||||||||||||||||||||
| CePDU2SourceInfoBank1Overload | 1.3.6.1.4.1.3808.1.1.6.9.3.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Bank 1 Current Overload event counts of Automatic Transfer Switch. Models that do not support this feature will respond to this OID with a value of (-1). | |||||||||||||||||||||
| CePDU2SourceInfoBank2Overload | 1.3.6.1.4.1.3808.1.1.6.9.3.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Bank 2 Current Overload event counts of Automatic Transfer Switch. Models that do not support this feature will respond to this OID with a value of (-1). | |||||||||||||||||||||
| CePDU2SourceInfoBank3Overload | 1.3.6.1.4.1.3808.1.1.6.9.3.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Bank 3 Current Overload event counts of Automatic Transfer Switch. Models that do not support this feature will respond to this OID with a value of (-1). | |||||||||||||||||||||
| TePDU2SourceStatusTable | 1.3.6.1.4.1.3808.1.1.6.9.4 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of Automatic Transfer Switch current status. | |||||||||||||||||||||
| RePDU2SourceStatusEntry | 1.3.6.1.4.1.3808.1.1.6.9.4.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Status data from the Automatic Transfer Switch being queried. | |||||||||||||||||||||
| CePDU2SourceStatusIndex | 1.3.6.1.4.1.3808.1.1.6.9.4.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The index to the Automatic Transfer Switch status table entry. | |||||||||||||||||||||
| CePDU2SourceStatusModuleIndex | 1.3.6.1.4.1.3808.1.1.6.9.4.1.2 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Automatic Transfer Switch numeric ID | |||||||||||||||||||||
| CePDU2SourceStatusSelectedSource | 1.3.6.1.4.1.3808.1.1.6.9.4.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the current source of power.
| |||||||||||||||||||||
| CePDU2SourceStatusNominalFrequency | 1.3.6.1.4.1.3808.1.1.6.9.4.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The Nominal Frequency in 0.1 Hertz. | |||||||||||||||||||||
| CePDU2SourceStatusSourceAVoltage | 1.3.6.1.4.1.3808.1.1.6.9.4.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage of source A in 0.1 Volt. | |||||||||||||||||||||
| CePDU2SourceStatusSourceBVoltage | 1.3.6.1.4.1.3808.1.1.6.9.4.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage of source B in 0.1 Volt. | |||||||||||||||||||||
| CePDU2SourceStatusSourceAFrequency | 1.3.6.1.4.1.3808.1.1.6.9.4.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input frequency of source A in 0.1 Hertz. | |||||||||||||||||||||
| CePDU2SourceStatusSourceBFrequency | 1.3.6.1.4.1.3808.1.1.6.9.4.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input frequency of source B in 0.1 Hertz. | |||||||||||||||||||||
| CePDU2SourceStatusSourceAVolStatus | 1.3.6.1.4.1.3808.1.1.6.9.4.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage status of source A.
| |||||||||||||||||||||
| CePDU2SourceStatusSourceBVolStatus | 1.3.6.1.4.1.3808.1.1.6.9.4.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input voltage status of source B.
| |||||||||||||||||||||
| CePDU2SourceStatusSourceAFreqStatus | 1.3.6.1.4.1.3808.1.1.6.9.4.1.11 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input frequency status of source A.
| |||||||||||||||||||||
| CePDU2SourceStatusSourceBFreqStatus | 1.3.6.1.4.1.3808.1.1.6.9.4.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The input frequency status of source B.
| |||||||||||||||||||||
| CePDU2SourceStatusSourcePhaseSync | 1.3.6.1.4.1.3808.1.1.6.9.4.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the status of the phase sync.
| |||||||||||||||||||||
| CePDU2SourceStatusPowerSupplySourceAStatus | 1.3.6.1.4.1.3808.1.1.6.9.4.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the status of the power supply in system. normal(1) indicates the power supply of source A in normal. 3.3vFailed(2) indicates the power supply 3.3v of source A is failed. 24vFailed(3) indicates the power supply 24v of source A is failed. 3.3and24vfailed(4) indicates both power supply 3.3 and 24v of source A is failed.
| |||||||||||||||||||||
| CePDU2SourceStatusPowerSupplySourceBStatus | 1.3.6.1.4.1.3808.1.1.6.9.4.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the status of the power supply in system. normal(1) indicates the power supply of source B in normal. 3.3vFailed(2) indicates the power supply 3.3v of source B is failed. 24vFailed(3) indicates the power supply 24v of source B is failed. 3.3and24vfailed(4) indicates both power supply 3.3 and 24v of source B is failed.
| |||||||||||||||||||||
| CePDU2SourceStatusRedundancyState | 1.3.6.1.4.1.3808.1.1.6.9.4.1.16 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory This variable returns the current redundancy state of the ATS. atsRedundancyLost(1) indicates that the ATS is unable to switch over to the alternate power source if the current source fails. atsFullyRedundant(2) indicates that the ATS will switch over to the alternate power source if the current source fails.
| |||||||||||||||||||||
| Nbattmgr | 1.3.6.1.4.1.3808.1.1.7 | ||||||||||||||||||||
| NbmIdent | 1.3.6.1.4.1.3808.1.1.7.1 | ||||||||||||||||||||
| SbmIdentModelName | 1.3.6.1.4.1.3808.1.1.7.1.1 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager model name. | |||||||||||||||||||||
| SbmIdentHardwareRev | 1.3.6.1.4.1.3808.1.1.7.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager hardware version. | |||||||||||||||||||||
| SbmIdentFirmwareRev | 1.3.6.1.4.1.3808.1.1.7.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager firmware version. | |||||||||||||||||||||
| SbmIdentLCDHardwareRev | 1.3.6.1.4.1.3808.1.1.7.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager LCD hardware version. | |||||||||||||||||||||
| SbmIdentLCDFirmwareRev | 1.3.6.1.4.1.3808.1.1.7.1.5 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager LCD firmware version. | |||||||||||||||||||||
| SbmIdentDateOfManufacture | 1.3.6.1.4.1.3808.1.1.7.1.6 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager manufacture date. | |||||||||||||||||||||
| SbmIdentSerialNumber | 1.3.6.1.4.1.3808.1.1.7.1.7 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager serial number. | |||||||||||||||||||||
| SbmIdentName | 1.3.6.1.4.1.3808.1.1.7.1.8 | DisplayString | RW | mandatory | |||||||||||||||||
scalar · DisplayString · read-write · mandatory Battery manager system identification name. | |||||||||||||||||||||
| SbmIdentLocation | 1.3.6.1.4.1.3808.1.1.7.1.9 | DisplayString | RW | mandatory | |||||||||||||||||
scalar · DisplayString · read-write · mandatory Battery manager system location. | |||||||||||||||||||||
| NbmProperty | 1.3.6.1.4.1.3808.1.1.7.2 | ||||||||||||||||||||
| SbmPropertyStringMax | 1.3.6.1.4.1.3808.1.1.7.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Battery manager max string count supported. | |||||||||||||||||||||
| SbmPropertyMaxProbeOnString | 1.3.6.1.4.1.3808.1.1.7.2.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Battery manager max probes on a string supported. | |||||||||||||||||||||
| SbmPropertyInputVoltageRange | 1.3.6.1.4.1.3808.1.1.7.2.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Battery manager line input voltage range. | |||||||||||||||||||||
| SbmPropertyProbesRating | 1.3.6.1.4.1.3808.1.1.7.2.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Battery probes model rating.
| |||||||||||||||||||||
| NbmConfig | 1.3.6.1.4.1.3808.1.1.7.3 | ||||||||||||||||||||
| SbmConfigBattAH | 1.3.6.1.4.1.3808.1.1.7.3.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery manager battery AH type configuration, unit in 0.1 AH. | |||||||||||||||||||||
| SbmConfigStringCount | 1.3.6.1.4.1.3808.1.1.7.3.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Configure number of battery strings to manage. | |||||||||||||||||||||
| SbmConfigProbesCountOnString | 1.3.6.1.4.1.3808.1.1.7.3.3 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Configure number of batteries on a string. | |||||||||||||||||||||
| SbmConfigLowVoltAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.4 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery low voltage alarm threshold setting, unit in 0.1 volt. | |||||||||||||||||||||
| SbmConfigHighVoltAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.5 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery high voltage alarm threshold setting, unit in 0.1 volt. | |||||||||||||||||||||
| SbmConfigVoltDiffAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.6 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Batteries within a string voltage difference threshold, unit in 0.1 volt. | |||||||||||||||||||||
| SbmConfigLowTempAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.7 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery low temperature alarm threshold, unit in 0.1 degree C. | |||||||||||||||||||||
| SbmConfigHighTempAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.8 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery high temperature alarm threshold, unit in 0.1 degree C. | |||||||||||||||||||||
| SbmConfigLowResAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.9 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery low resistance alarm threshold, unit in 0.01 mOhm. | |||||||||||||||||||||
| SbmConfigHighResAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.10 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery high resistance alarm threshold, unit in 0.01 mOhm. | |||||||||||||||||||||
| SbmConfigLowResWarnThreshold | 1.3.6.1.4.1.3808.1.1.7.3.11 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery low resistance warning threshold, unit in 0.01 mOhm. | |||||||||||||||||||||
| SbmConfigHighResWarnThreshold | 1.3.6.1.4.1.3808.1.1.7.3.12 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery high resistance warning threshold, unit in 0.01 mOhm. | |||||||||||||||||||||
| SbmConfigResHealthAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.13 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery resistance health alarm threshold, unit in percentage and should larger than 100. | |||||||||||||||||||||
| SbmConfigResHealthWarnThreshold | 1.3.6.1.4.1.3808.1.1.7.3.14 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery resistance health warn threshold, unit in percentage and should larger than 100. | |||||||||||||||||||||
| SbmConfigLowVoltAlarmThreshold10mV | 1.3.6.1.4.1.3808.1.1.7.3.15 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery low voltage alarm threshold setting, unit in 10 mV (0.01 volt). | |||||||||||||||||||||
| SbmConfigHighVoltAlarmThreshold10mV | 1.3.6.1.4.1.3808.1.1.7.3.16 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery high voltage alarm threshold setting, unit in 10 mV (0.01 volt). | |||||||||||||||||||||
| SbmConfigMergeFeature | 1.3.6.1.4.1.3808.1.1.7.3.17 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Enable/Disable merge feature. Setting this OID may result in erasing existed battery records.
| |||||||||||||||||||||
| SbmConfigLowStringVoltageAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.20 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory String low voltage alarm threshold setting, unit in 0.1 volt. | |||||||||||||||||||||
| SbmConfigHighStringVoltageAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.21 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory String high voltage alarm threshold setting, unit in 0.1 volt. | |||||||||||||||||||||
| SbmConfigLowStringVoltageWarnThreshold | 1.3.6.1.4.1.3808.1.1.7.3.22 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory String low voltage warning threshold setting, unit in 0.1 volt. | |||||||||||||||||||||
| SbmConfigHighStringVoltageWarnThreshold | 1.3.6.1.4.1.3808.1.1.7.3.23 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory String high voltage warning threshold setting, unit in 0.1 volt. | |||||||||||||||||||||
| SbmConfigLowStringSocAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.24 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory String low soc alarm threshold setting, unit in 1%. | |||||||||||||||||||||
| SbmConfigLowStringSocWarnThreshold | 1.3.6.1.4.1.3808.1.1.7.3.25 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory String low soc warning threshold setting, unit in %1. | |||||||||||||||||||||
| SbmConfigLowBattSocAlarmThreshold | 1.3.6.1.4.1.3808.1.1.7.3.26 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery low soc alarm threshold setting, unit in 1%. | |||||||||||||||||||||
| SbmConfigLowBattSocWarnThreshold | 1.3.6.1.4.1.3808.1.1.7.3.27 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery low soc warning threshold setting, unit in 1%. | |||||||||||||||||||||
| NbmControl | 1.3.6.1.4.1.3808.1.1.7.4 | ||||||||||||||||||||
| SbmControlSysytemIdenticator | 1.3.6.1.4.1.3808.1.1.7.4.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery manager will perform a panel indicator test when the variable is set to testIndicators(2). Get this oid will get noTestIndicators(1).
| |||||||||||||||||||||
| SbmControlProbeIndicator | 1.3.6.1.4.1.3808.1.1.7.4.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery manager will perform a probe indicator test when the variable is set to testIndicators(2). Get this oid will get noTestIndicators(1).
| |||||||||||||||||||||
| NbmProbes | 1.3.6.1.4.1.3808.1.1.7.5 | ||||||||||||||||||||
| SbmProbesNum | 1.3.6.1.4.1.3808.1.1.7.5.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Current connected probe number. | |||||||||||||||||||||
| SbmProbesTableSize | 1.3.6.1.4.1.3808.1.1.7.5.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Current configured probe number. | |||||||||||||||||||||
| TbmProbesTable | 1.3.6.1.4.1.3808.1.1.7.5.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The battery probes installation information. | |||||||||||||||||||||
| RbmProbesEntry | 1.3.6.1.4.1.3808.1.1.7.5.3.1 | NA | mandatory | ||||||||||||||||||
| CbmProbesIndex | 1.3.6.1.4.1.3808.1.1.7.5.3.1.1 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index of the bmProbesEntry entry. | |||||||||||||||||||||
| CbmProbesPackIndex | 1.3.6.1.4.1.3808.1.1.7.5.3.1.2 | INTEGER (1..64) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..64) · read-only · mandatory The pack number the battery probe installed. | |||||||||||||||||||||
| CbmProbesStringIndex | 1.3.6.1.4.1.3808.1.1.7.5.3.1.3 | INTEGER (1..16) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..16) · read-only · mandatory The string number the battery probe installed. | |||||||||||||||||||||
| CbmProbesBattIndex | 1.3.6.1.4.1.3808.1.1.7.5.3.1.4 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The battery number the battery probe installed. | |||||||||||||||||||||
| SbmProbesVoltageTableSize | 1.3.6.1.4.1.3808.1.1.7.5.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the battery voltage table | |||||||||||||||||||||
| TbmProbesVoltageTable | 1.3.6.1.4.1.3808.1.1.7.5.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The batteries voltage information. | |||||||||||||||||||||
| RbmProbesVoltageEntry | 1.3.6.1.4.1.3808.1.1.7.5.5.1 | NA | mandatory | ||||||||||||||||||
| CbmProbesVoltageIndex | 1.3.6.1.4.1.3808.1.1.7.5.5.1.1 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index of the BmProbesVoltageEntry entry. | |||||||||||||||||||||
| CbmProbesVoltagePackIndex | 1.3.6.1.4.1.3808.1.1.7.5.5.1.2 | INTEGER (1..64) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..64) · read-only · mandatory The battery pack number the battery voltage reading belongs to. | |||||||||||||||||||||
| CbmProbesVoltageStringIndex | 1.3.6.1.4.1.3808.1.1.7.5.5.1.3 | INTEGER (1..16) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..16) · read-only · mandatory The battery string number the battery voltage reading belongs to. | |||||||||||||||||||||
| CbmProbesVoltageBattIndex | 1.3.6.1.4.1.3808.1.1.7.5.5.1.4 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The battery index to the voltage record within its string. | |||||||||||||||||||||
| CbmProbesVoltageProbeIndex | 1.3.6.1.4.1.3808.1.1.7.5.5.1.5 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The probe index to the voltage record. | |||||||||||||||||||||
| CbmProbesVoltageAlarmStatus | 1.3.6.1.4.1.3808.1.1.7.5.5.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The battery voltage alarm status.
| |||||||||||||||||||||
| CbmProbesVoltage | 1.3.6.1.4.1.3808.1.1.7.5.5.1.7 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this oid to get battery voltage, unit in 10mV (0.01 volt). | |||||||||||||||||||||
| CbmProbesVoltageEqualPercentage | 1.3.6.1.4.1.3808.1.1.7.5.5.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this oid to get battery voltage equalizing power, unit in percentage. | |||||||||||||||||||||
| CbmProbesVoltageSocAlarmStatus | 1.3.6.1.4.1.3808.1.1.7.5.5.1.9 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The battery soc alarm status.
| |||||||||||||||||||||
| CbmProbesVoltageSoc | 1.3.6.1.4.1.3808.1.1.7.5.5.1.10 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this oid to get battery soc, unit in percentage. | |||||||||||||||||||||
| SbmProbesTempTableSize | 1.3.6.1.4.1.3808.1.1.7.5.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the battery temperature table | |||||||||||||||||||||
| TbmProbesTempTable | 1.3.6.1.4.1.3808.1.1.7.5.7 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The batteries temperature information. | |||||||||||||||||||||
| RbmProbesTempEntry | 1.3.6.1.4.1.3808.1.1.7.5.7.1 | NA | mandatory | ||||||||||||||||||
| CbmProbesTempIndex | 1.3.6.1.4.1.3808.1.1.7.5.7.1.1 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index of the BmProbesTempEntry entry. | |||||||||||||||||||||
| CbmProbesTempPackIndex | 1.3.6.1.4.1.3808.1.1.7.5.7.1.2 | INTEGER (1..64) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..64) · read-only · mandatory The battery pack number the battery temperature reading belongs to. | |||||||||||||||||||||
| CbmProbesTempStringIndex | 1.3.6.1.4.1.3808.1.1.7.5.7.1.3 | INTEGER (1..16) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..16) · read-only · mandatory The battery string number the battery temperature reading belongs to. | |||||||||||||||||||||
| CbmProbesTempBattIndex | 1.3.6.1.4.1.3808.1.1.7.5.7.1.4 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index to the battery. | |||||||||||||||||||||
| CbmProbesTempProbeIndex | 1.3.6.1.4.1.3808.1.1.7.5.7.1.5 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index to the probe. | |||||||||||||||||||||
| CbmProbesTempAlarmStatus | 1.3.6.1.4.1.3808.1.1.7.5.7.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The alarm status of the temperature.
| |||||||||||||||||||||
| CbmProbesTemperature | 1.3.6.1.4.1.3808.1.1.7.5.7.1.7 | INTEGER (-40..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (-40..100) · read-only · mandatory The temperature record, measure in 0.1 degree C. | |||||||||||||||||||||
| SbmProbesResTableSize | 1.3.6.1.4.1.3808.1.1.7.5.8 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the battery resistance table | |||||||||||||||||||||
| TbmProbesResTable | 1.3.6.1.4.1.3808.1.1.7.5.9 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory The batteries resistance information. | |||||||||||||||||||||
| RbmProbesResEntry | 1.3.6.1.4.1.3808.1.1.7.5.9.1 | NA | mandatory | ||||||||||||||||||
| CbmProbesResIndex | 1.3.6.1.4.1.3808.1.1.7.5.9.1.1 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index of the BmProbesResEntry entry. | |||||||||||||||||||||
| CbmProbesResPackIndex | 1.3.6.1.4.1.3808.1.1.7.5.9.1.2 | INTEGER (1..64) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..64) · read-only · mandatory The battery pack number the battery resistance reading belongs to. | |||||||||||||||||||||
| CbmProbesResStringIndex | 1.3.6.1.4.1.3808.1.1.7.5.9.1.3 | INTEGER (1..16) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..16) · read-only · mandatory The battery string number the battery resistance reading belongs to. | |||||||||||||||||||||
| CbmProbesResBattIndex | 1.3.6.1.4.1.3808.1.1.7.5.9.1.4 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index to the battery. | |||||||||||||||||||||
| CbmProbesResProbeIndex | 1.3.6.1.4.1.3808.1.1.7.5.9.1.5 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The index to the probe. | |||||||||||||||||||||
| CbmProbesResAlarmStatus | 1.3.6.1.4.1.3808.1.1.7.5.9.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The alarm status of the battery resistance.
| |||||||||||||||||||||
| CbmProbesResistance | 1.3.6.1.4.1.3808.1.1.7.5.9.1.7 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The resistance of the battery, unit in 0.01 mOhm. | |||||||||||||||||||||
| CbmProbesResHealth | 1.3.6.1.4.1.3808.1.1.7.5.9.1.8 | INTEGER (0..100) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..100) · read-only · mandatory The resistance health status, unit in percentage. | |||||||||||||||||||||
| NbmFuncRes | 1.3.6.1.4.1.3808.1.1.7.6 | ||||||||||||||||||||
| NbmFuncResMeasure | 1.3.6.1.4.1.3808.1.1.7.6.1 | ||||||||||||||||||||
| SbmFuncResMeasureInterval | 1.3.6.1.4.1.3808.1.1.7.6.1.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The time interval for battery manager to exercising resistance measurement, unit in hour(s). | |||||||||||||||||||||
| SbmFuncResMeasureManualCmd | 1.3.6.1.4.1.3808.1.1.7.6.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory This oid allows user to manual resistance measurement. Set this oid to measureResNow(2) to measure resistance immediately. Get bmFuncResMeasureLastCmdResult oid to check command acceptance.
| |||||||||||||||||||||
| SbmFuncResMeasureManualResult | 1.3.6.1.4.1.3808.1.1.7.6.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Get this oid to confirm the last manual command result.
| |||||||||||||||||||||
| SbmFuncResMeasureLastUpdate | 1.3.6.1.4.1.3808.1.1.7.6.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory When resistance measurement complete either by auto or manual, this oid will update to the last update time. | |||||||||||||||||||||
| NbmFuncEqual | 1.3.6.1.4.1.3808.1.1.7.7 | ||||||||||||||||||||
| SbmFuncEqualEnable | 1.3.6.1.4.1.3808.1.1.7.7.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Battery voltage equalization configuration.
| |||||||||||||||||||||
| SbmFuncEqualActiveCond | 1.3.6.1.4.1.3808.1.1.7.7.2 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Volatge equalization will active when the voltage difference larger than this value, unit in 10mV. | |||||||||||||||||||||
| SbmFuncEqualStatus | 1.3.6.1.4.1.3808.1.1.7.7.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory This oid shows the current equalization status.
| |||||||||||||||||||||
| SbmFuncEqualStartTime | 1.3.6.1.4.1.3808.1.1.7.7.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory This oid shows the last equalization start time. | |||||||||||||||||||||
| SbmFuncEqualElapseTime | 1.3.6.1.4.1.3808.1.1.7.7.5 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory This oid shows the elapsed time since last equalization started. | |||||||||||||||||||||
| NbmStrings | 1.3.6.1.4.1.3808.1.1.7.10 | ||||||||||||||||||||
| SbmStringsNum | 1.3.6.1.4.1.3808.1.1.7.10.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Current connected string number. | |||||||||||||||||||||
| SbmStringsTableSize | 1.3.6.1.4.1.3808.1.1.7.10.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Current configured string number. | |||||||||||||||||||||
| TbmStringsTable | 1.3.6.1.4.1.3808.1.1.7.10.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of status of strings. | |||||||||||||||||||||
| RbmStringsEntry | 1.3.6.1.4.1.3808.1.1.7.10.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The status of strings installation to gather status from.
| |||||||||||||||||||||
| CbmStringsIndex | 1.3.6.1.4.1.3808.1.1.7.10.3.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory Strings table index | |||||||||||||||||||||
| CbmStringsPackIndex | 1.3.6.1.4.1.3808.1.1.7.10.3.1.2 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The battery pack number the string installed. | |||||||||||||||||||||
| CbmStringsProbeCount | 1.3.6.1.4.1.3808.1.1.7.10.3.1.3 | INTEGER (1..960) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..960) · read-only · mandatory The probe number installed in string. | |||||||||||||||||||||
| SbmStringsVoltageTableSize | 1.3.6.1.4.1.3808.1.1.7.10.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The size of the string voltage table | |||||||||||||||||||||
| TbmStringsVoltageTable | 1.3.6.1.4.1.3808.1.1.7.10.5 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of voltage of strings. | |||||||||||||||||||||
| RbmStringsVoltageEntry | 1.3.6.1.4.1.3808.1.1.7.10.5.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The status of string voltage installation to gather status from. | |||||||||||||||||||||
| CbmStringsVoltageIndex | 1.3.6.1.4.1.3808.1.1.7.10.5.1.1 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory Strings table index | |||||||||||||||||||||
| CbmStringsVoltagePackIndex | 1.3.6.1.4.1.3808.1.1.7.10.5.1.2 | INTEGER (1..10) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..10) · read-only · mandatory The battery pack number the string installed. | |||||||||||||||||||||
| CbmStringsVoltageAlarmStatus | 1.3.6.1.4.1.3808.1.1.7.10.5.1.3 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The string voltage alarm status.
| |||||||||||||||||||||
| CbmStringsVoltage | 1.3.6.1.4.1.3808.1.1.7.10.5.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this oid to get string voltage, unit in 10mV (0.01 V). | |||||||||||||||||||||
| CbmStringsVoltageSocAlarmStatus | 1.3.6.1.4.1.3808.1.1.7.10.5.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The string soc alarm status.
| |||||||||||||||||||||
| CbmStringsVoltageSoc | 1.3.6.1.4.1.3808.1.1.7.10.5.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this oid to get string soc, unit in 1%. | |||||||||||||||||||||
| NbmFuncShutdown | 1.3.6.1.4.1.3808.1.1.7.20 | ||||||||||||||||||||
| SbmFuncShutdownVolt | 1.3.6.1.4.1.3808.1.1.7.20.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory Shutdown voltage threshold setting, unit in 1 mV.(0.01 V) | |||||||||||||||||||||
| SbmFuncShutdownStatus | 1.3.6.1.4.1.3808.1.1.7.20.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The low voltage shutdown status.
| |||||||||||||||||||||
| SbmShutdownDownCount | 1.3.6.1.4.1.3808.1.1.7.20.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Down count before battery probe shutdown, unit in minute. | |||||||||||||||||||||
| NbmWireless | 1.3.6.1.4.1.3808.1.1.7.50 | ||||||||||||||||||||
| NbmWirelessProperty | 1.3.6.1.4.1.3808.1.1.7.50.1 | ||||||||||||||||||||
| SbmWirelessPropertyMAC | 1.3.6.1.4.1.3808.1.1.7.50.1.1 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The battery manager wireless module MAC address. | |||||||||||||||||||||
| SbmWirelessPropertyHwInfo | 1.3.6.1.4.1.3808.1.1.7.50.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The battery manager wireless module hardware information. | |||||||||||||||||||||
| SbmWirelessPropertyFwInfo | 1.3.6.1.4.1.3808.1.1.7.50.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The battery manager wireless module firmware information. | |||||||||||||||||||||
| NbmWirelessStatus | 1.3.6.1.4.1.3808.1.1.7.50.2 | ||||||||||||||||||||
| SbmWirelessStatusState | 1.3.6.1.4.1.3808.1.1.7.50.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery manager wireless module status.
| |||||||||||||||||||||
| SbmWirelessStatusChannel | 1.3.6.1.4.1.3808.1.1.7.50.2.2 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery manager wireless network channel number. | |||||||||||||||||||||
| SbmWirelessStatusPANID | 1.3.6.1.4.1.3808.1.1.7.50.2.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery manager wireless network PAN ID number. | |||||||||||||||||||||
| SbmWirelessStatusLinkedNodes | 1.3.6.1.4.1.3808.1.1.7.50.2.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The battery manager wireless network linked node numbder. | |||||||||||||||||||||
| NbmWirelessConfig | 1.3.6.1.4.1.3808.1.1.7.50.3 | ||||||||||||||||||||
| SbmWirelessConfigJoin | 1.3.6.1.4.1.3808.1.1.7.50.3.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The battery manager wireless network auto join configuration.
| |||||||||||||||||||||
| NbmWirelessControl | 1.3.6.1.4.1.3808.1.1.7.50.4 | ||||||||||||||||||||
| SbmWirelessControlRestart | 1.3.6.1.4.1.3808.1.1.7.50.4.1 | INTEGER | RW | mandatory | |||||||||||||||||
scalar · INTEGER · read-write · mandatory The battery manager wireless network auto join configuration.
| |||||||||||||||||||||
| NenvironmentSensor2 | 1.3.6.1.4.1.3808.1.1.8 | ||||||||||||||||||||
| Nenvir2Ident | 1.3.6.1.4.1.3808.1.1.8.1 | ||||||||||||||||||||
| Senvir2IdentTableSize | 1.3.6.1.4.1.3808.1.1.8.1.1 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tenvir2IdentTable | 1.3.6.1.4.1.3808.1.1.8.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of environment sensor identification information. | |||||||||||||||||||||
| Renvir2IdentEntry | 1.3.6.1.4.1.3808.1.1.8.1.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Identification data from environment sensor being queried.
| |||||||||||||||||||||
| Cenvir2IdentIndex | 1.3.6.1.4.1.3808.1.1.8.1.2.1.1 | INTEGER (1..8) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..8) · read-only · mandatory The index to the environment sensor table entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2IdentModulePosition | 1.3.6.1.4.1.3808.1.1.8.1.2.1.2 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER · read-only · mandatory The position of environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2IdentName | 1.3.6.1.4.1.3808.1.1.8.1.2.1.3 | DisplayString | RW | mandatory | example.com | ||||||||||||||||
column · DisplayString · read-write · mandatory The name of the environment sensor. The maximum string size is device dependent. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2IdentLocation | 1.3.6.1.4.1.3808.1.1.8.1.2.1.4 | DisplayString | RW | mandatory | Location | ||||||||||||||||
column · DisplayString · read-write · mandatory The location of the environment sensor. The maximum string size is device dependent. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2IdentSerialNumber | 1.3.6.1.4.1.3808.1.1.8.1.2.1.5 | DisplayString | RO | mandatory | TBLPZ2000115 | ||||||||||||||||
column · DisplayString · read-only · mandatory The serial number of the environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nenvir2Temp | 1.3.6.1.4.1.3808.1.1.8.2 | ||||||||||||||||||||
| Senvir2TempTableSize | 1.3.6.1.4.1.3808.1.1.8.2.1 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Senvir2TempUnit | 1.3.6.1.4.1.3808.1.1.8.2.2 | INTEGER | RW | mandatory | fahrenheit(2) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory This OID describes the unit of environment sensor. Setting the OID to Celsius(1) or Fahrenheit(2) to change the temperature unit.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tenvir2TempTable | 1.3.6.1.4.1.3808.1.1.8.2.3 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of environment sensor identification information in temperature. | |||||||||||||||||||||
| Renvir2TempEntry | 1.3.6.1.4.1.3808.1.1.8.2.3.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Identification data from environment sensor being queried. | |||||||||||||||||||||
| Cenvir2TemperatureIndex | 1.3.6.1.4.1.3808.1.1.8.2.3.1.1 | INTEGER (1..8) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..8) · read-only · mandatory The index to the environment sensor table entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2TempModulePosition | 1.3.6.1.4.1.3808.1.1.8.2.3.1.2 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER · read-only · mandatory The position of environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2Temperature | 1.3.6.1.4.1.3808.1.1.8.2.3.1.3 | INTEGER | RO | mandatory | 8304 | ||||||||||||||||
column · INTEGER · read-only · mandatory The environment temperature expressed in 1/100. The value is determined by temperature unit which can be changed in envir2TempUnit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2TempHighThreshold | 1.3.6.1.4.1.3808.1.1.8.2.3.1.4 | INTEGER | RW | mandatory | 100 | ||||||||||||||||
column · INTEGER · read-write · mandatory The high temperature threshold of the environment sensor. The value is determined by temperature unit which can be changed in envir2TempUnit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2TempLowThreshold | 1.3.6.1.4.1.3808.1.1.8.2.3.1.5 | INTEGER | RW | mandatory | 40 | ||||||||||||||||
column · INTEGER · read-write · mandatory The low temperature threshold of the environment sensor. The value is determined by temperature unit which can be changed in envir2TempUnit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2TempRateOfChange | 1.3.6.1.4.1.3808.1.1.8.2.3.1.6 | INTEGER | RW | mandatory | 18 | ||||||||||||||||
column · INTEGER · read-write · mandatory The rate of change of the temperature. The value expressed in degree per 5 minute. The value is determined by temperature unit which can be changed in envir2TempUnit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2TempHysteresis | 1.3.6.1.4.1.3808.1.1.8.2.3.1.7 | INTEGER | RW | mandatory | 4 | ||||||||||||||||
column · INTEGER · read-write · mandatory The number of degrees beyond the temperature thresholds at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. The value is determined by temperature unit which can be changed in envir2TempUnit. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nenvir2Humid | 1.3.6.1.4.1.3808.1.1.8.3 | ||||||||||||||||||||
| Senvir2HumidTableSize | 1.3.6.1.4.1.3808.1.1.8.3.1 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tenvir2HumidTable | 1.3.6.1.4.1.3808.1.1.8.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A table of environment sensor identification information in humidity. | |||||||||||||||||||||
| Renvir2HumidEntry | 1.3.6.1.4.1.3808.1.1.8.3.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Identification data from environment sensor being queried.
| |||||||||||||||||||||
| Cenvir2HumidityIndex | 1.3.6.1.4.1.3808.1.1.8.3.2.1.1 | INTEGER (1..8) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..8) · read-only · mandatory The index to the environment sensor table entry. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2HumidModulePosition | 1.3.6.1.4.1.3808.1.1.8.3.2.1.2 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER · read-only · mandatory The position of environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2Humidity | 1.3.6.1.4.1.3808.1.1.8.3.2.1.3 | INTEGER | RO | mandatory | 8479 | ||||||||||||||||
column · INTEGER · read-only · mandatory The environment relative humidity expressed in 1/100. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2HumidHighThreshold | 1.3.6.1.4.1.3808.1.1.8.3.2.1.4 | INTEGER | RW | mandatory | 80 | ||||||||||||||||
column · INTEGER · read-write · mandatory The high relative humidity threshold of the environment sensor. The value expressed in persentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2HumidLowThreshold | 1.3.6.1.4.1.3808.1.1.8.3.2.1.5 | INTEGER | RW | mandatory | 20 | ||||||||||||||||
column · INTEGER · read-write · mandatory The low relative humidity threshold of the environment sensor. The value expressed in persentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2HumidRateOfChange | 1.3.6.1.4.1.3808.1.1.8.3.2.1.6 | INTEGER | RW | mandatory | 20 | ||||||||||||||||
column · INTEGER · read-write · mandatory The rate of change of the relative humidity. The value expressed in persentage per 5 minute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2HumidHysteresis | 1.3.6.1.4.1.3808.1.1.8.3.2.1.7 | INTEGER | RW | mandatory | 5 | ||||||||||||||||
column · INTEGER · read-write · mandatory The number of degrees beyond the relative humidity thresholds at which an active relative humidity alarm will be cleared. This configuration setting applies to all relative humidity thresholds. Units are displayed in persentage. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nenvir2Contact | 1.3.6.1.4.1.3808.1.1.8.4 | ||||||||||||||||||||
| Senvir2ContactTableSize | 1.3.6.1.4.1.3808.1.1.8.4.1 | INTEGER | RO | mandatory | 4 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of the contact in the environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Tenvir2ContactTable | 1.3.6.1.4.1.3808.1.1.8.4.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Allows for getting of information of each contact of the environment sensor. | |||||||||||||||||||||
| Renvir2ContactEntry | 1.3.6.1.4.1.3808.1.1.8.4.2.1 | NA | mandatory | ||||||||||||||||||
| Cenvir2ContactIndex | 1.3.6.1.4.1.3808.1.1.8.4.2.1.1 | INTEGER (1..32) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..32) · read-only · mandatory The index to the contact of the environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2ContactModulePosition | 1.3.6.1.4.1.3808.1.1.8.4.2.1.2 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER · read-only · mandatory The position of environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2ContactModuleNumber | 1.3.6.1.4.1.3808.1.1.8.4.2.1.3 | INTEGER | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER · read-only · mandatory The numeric contact ID. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2ContactName | 1.3.6.1.4.1.3808.1.1.8.4.2.1.4 | DisplayString | RW | mandatory | Door Alarm | ||||||||||||||||
column · DisplayString · read-write · mandatory Getting or setting the name of the contact of the environment sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2ContactStatus | 1.3.6.1.4.1.3808.1.1.8.4.2.1.5 | INTEGER | RO | mandatory | contactNormal(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory Getting this OID will return the Contact Status.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Cenvir2ContactNormalState | 1.3.6.1.4.1.3808.1.1.8.4.2.1.6 | INTEGER | RW | mandatory | normalOpen(1) | ||||||||||||||||
column · INTEGER · read-write · mandatory Set the contact normal state.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| NcurrentProbe | 1.3.6.1.4.1.3808.1.1.50 | ||||||||||||||||||||
| NcurrIdent | 1.3.6.1.4.1.3808.1.1.50.1 | ||||||||||||||||||||
| ScurrIdentSystemID | 1.3.6.1.4.1.3808.1.1.50.1.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Current probe connecting system type information.
| |||||||||||||||||||||
| ScurrIdentSystemSerialNumber | 1.3.6.1.4.1.3808.1.1.50.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Current probe connecting system serial number information. | |||||||||||||||||||||
| ScurrIdentSystemName | 1.3.6.1.4.1.3808.1.1.50.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Current probe connecting system name information. | |||||||||||||||||||||
| ScurrIdentSystemLocation | 1.3.6.1.4.1.3808.1.1.50.1.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Current probe connecting system location information. | |||||||||||||||||||||
| ScurrIdentTableSize | 1.3.6.1.4.1.3808.1.1.50.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number of current probe connecting to the system. | |||||||||||||||||||||
| TcurrIdentTable | 1.3.6.1.4.1.3808.1.1.50.1.6 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Current probe identification table. | |||||||||||||||||||||
| RcurrIdentEntry | 1.3.6.1.4.1.3808.1.1.50.1.6.1 | NA | mandatory | ||||||||||||||||||
| CcurrIdentIndex | 1.3.6.1.4.1.3808.1.1.50.1.6.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The current probe ident index. | |||||||||||||||||||||
| CcurrIdentName | 1.3.6.1.4.1.3808.1.1.50.1.6.1.2 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The current probe ident name. | |||||||||||||||||||||
| CcurrIdentLocation | 1.3.6.1.4.1.3808.1.1.50.1.6.1.3 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory The current probe ident location. | |||||||||||||||||||||
| CcurrIdentMeasureNum | 1.3.6.1.4.1.3808.1.1.50.1.6.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Number of the current flow measure by the current probe. | |||||||||||||||||||||
| NcurrConfig | 1.3.6.1.4.1.3808.1.1.50.2 | ||||||||||||||||||||
| ScurrConfigTableSize | 1.3.6.1.4.1.3808.1.1.50.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Number of entry in the currConfigTable. | |||||||||||||||||||||
| TcurrConfigTable | 1.3.6.1.4.1.3808.1.1.50.2.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table provides current flow's configuration parameters. | |||||||||||||||||||||
| RcurrConfigEntry | 1.3.6.1.4.1.3808.1.1.50.2.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The current flow's configration parameters entry.
| |||||||||||||||||||||
| CcurrConfigIndex | 1.3.6.1.4.1.3808.1.1.50.2.2.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory Entry index. | |||||||||||||||||||||
| CcurrConfigCurrentSensorRating | 1.3.6.1.4.1.3808.1.1.50.2.2.1.2 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Connecting current sensor element's rating, unit in 1 A. Sets to 0 if you do not use current sensor for this measure channel. Gets as 0 if this measure channel had not used. | |||||||||||||||||||||
| CcurrConfigChargeCurrentWarningLow | 1.3.6.1.4.1.3808.1.1.50.2.2.1.3 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Warning threshold for low charge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigChargeCurrentWarningHigh | 1.3.6.1.4.1.3808.1.1.50.2.2.1.4 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Warning threshold for high charge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigChargeCurrentAlarmLow | 1.3.6.1.4.1.3808.1.1.50.2.2.1.5 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Alarm threshold for low charge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigChargeCurrentAlarmHigh | 1.3.6.1.4.1.3808.1.1.50.2.2.1.6 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Alarm threshold for high charge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigDischargeCurrentWarningLow | 1.3.6.1.4.1.3808.1.1.50.2.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Warning threshold for low discharge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigDischargeCurrentWarningHigh | 1.3.6.1.4.1.3808.1.1.50.2.2.1.8 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Warning threshold for high discharge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigDischargeCurrentAlarmLow | 1.3.6.1.4.1.3808.1.1.50.2.2.1.9 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Alarm threshold for low discharge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigDischargeCurrentAlarmHigh | 1.3.6.1.4.1.3808.1.1.50.2.2.1.10 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Alarm threshold for high discharge current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigRMSCurrentWarninigLow | 1.3.6.1.4.1.3808.1.1.50.2.2.1.11 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Warning threshold for low RMS current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigRMSCurrentWarningHigh | 1.3.6.1.4.1.3808.1.1.50.2.2.1.12 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Warning threshold for high RMS current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigRMSCurrentAlarmLow | 1.3.6.1.4.1.3808.1.1.50.2.2.1.13 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Alarm threshold for low RMS current, unit in 0.01A. | |||||||||||||||||||||
| CcurrConfigRMSCurrentAlarmHigh | 1.3.6.1.4.1.3808.1.1.50.2.2.1.14 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Alarm threshold for high RMS current, unit in 0.01A. | |||||||||||||||||||||
| NcurrMeasure | 1.3.6.1.4.1.3808.1.1.50.3 | ||||||||||||||||||||
| ScurrMeasureTableSize | 1.3.6.1.4.1.3808.1.1.50.3.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Table size for the current probe's measurement. | |||||||||||||||||||||
| TcurrMeasureTable | 1.3.6.1.4.1.3808.1.1.50.3.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Table for the current probe's measurement. | |||||||||||||||||||||
| RcurrMeasureEntry | 1.3.6.1.4.1.3808.1.1.50.3.2.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory The status of current sensors installation to gather status from.
| |||||||||||||||||||||
| CcurrMeasureIndex | 1.3.6.1.4.1.3808.1.1.50.3.2.1.1 | INTEGER (1..4) | RO | mandatory | |||||||||||||||||
column · INTEGER (1..4) · read-only · mandatory The current measurement's index. | |||||||||||||||||||||
| CcurrMeasureIdentName | 1.3.6.1.4.1.3808.1.1.50.3.2.1.2 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The current measurement's current probe name. | |||||||||||||||||||||
| CcurrMeasureDescription | 1.3.6.1.4.1.3808.1.1.50.3.2.1.3 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory Current flow measurement's description. | |||||||||||||||||||||
| CcurrMeasureAlarmStatus | 1.3.6.1.4.1.3808.1.1.50.3.2.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The current alarm status. For battery system, abnormal value can be (2) to (9). For AC measure condition, abnormal value can be (50) to (53).
| |||||||||||||||||||||
| CcurrMeasureChargingState | 1.3.6.1.4.1.3808.1.1.50.3.2.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory For battery system to get battery charging state.
| |||||||||||||||||||||
| CcurrMeasureCurrent | 1.3.6.1.4.1.3808.1.1.50.3.2.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Getting this oid to get current measurement, unit in 10mA (0.01 A). For battery system, negative value indicates the discharge state. | |||||||||||||||||||||
| CcurrMeasureFunction | 1.3.6.1.4.1.3808.1.1.50.3.2.1.7 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory Getting this oid to check the configuration be matched with actual installation. Setting this oid to tell system what the measure target is. For the DC current(prefix as dc), charge/discharge threshold would be considered and used. For the AC current(prefix ad ac), RMS threshold would be considered and used.
| |||||||||||||||||||||
| Ncpsmgmt | 1.3.6.1.4.1.3808.2 | ||||||||||||||||||||
| Nmconfig | 1.3.6.1.4.1.3808.2.1 | ||||||||||||||||||||
| SmconfigNumTrapAccepters | 1.3.6.1.4.1.3808.2.1.1 | INTEGER | RO | mandatory | 10 | ||||||||||||||||
scalar · INTEGER · read-only · mandatory The number of receivers to send traps to. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TmconfigTrapAccepterTable | 1.3.6.1.4.1.3808.2.1.2 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory A list of receivers to send traps to. The numbers of entries are given by the value of mconfigNumTrapAccepters. | |||||||||||||||||||||
| RmconfigTrapAccepterEntry | 1.3.6.1.4.1.3808.2.1.2.1 | NA | mandatory | ||||||||||||||||||
| CtrapIndex | 1.3.6.1.4.1.3808.2.1.2.1.1 | INTEGER (1..10) | NA | mandatory | 1 | ||||||||||||||||
column · INTEGER (1..10) · not-accessible · mandatory The trap receiver entry index. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CaccepterAddr | 1.3.6.1.4.1.3808.2.1.2.1.2 | IpAddress | RW | mandatory | 172.16.161.75 | ||||||||||||||||
column · IpAddress · read-write · mandatory The trap receiver IP address. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcommunityString | 1.3.6.1.4.1.3808.2.1.2.1.3 | DisplayString | RW | mandatory | public | ||||||||||||||||
column · DisplayString · read-write · mandatory The trap receiver community name. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CseverityDegree | 1.3.6.1.4.1.3808.2.1.2.1.4 | INTEGER | RO | mandatory | information(1) | ||||||||||||||||
column · INTEGER · read-only · mandatory The trap receiver severity level. Traps are marked in severity level as informational(1), warning(2), severe(3). Only send the traps of equal or greater severity than this value to the receiver.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| CaccepterActive | 1.3.6.1.4.1.3808.2.1.2.1.5 | INTEGER | RW | mandatory | yes(1) | ||||||||||||||||
column · INTEGER · read-write · mandatory A receiver will accept traps if yes, and none if no.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmconfigDHCPEnabled | 1.3.6.1.4.1.3808.2.1.3 | INTEGER | RW | mandatory | no(2) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory The system will automatically obtain its IP from a DHCP server if yes, and none if no.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmconfigMyAddr | 1.3.6.1.4.1.3808.2.1.4 | IpAddress | RO | mandatory | 172.23.175.107 | ||||||||||||||||
scalar · IpAddress · read-only · mandatory The system IP address. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NmconfigClock | 1.3.6.1.4.1.3808.2.1.5 | ||||||||||||||||||||
| SmconfigClockDate | 1.3.6.1.4.1.3808.2.1.5.1 | DisplayString | RW | mandatory | 07/03/2026 | ||||||||||||||||
scalar · DisplayString · read-write · mandatory The current date in the mm/dd/yyyy format. Example: 01/01/2000. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmconfigClockTime | 1.3.6.1.4.1.3808.2.1.5.2 | DisplayString | RW | mandatory | 05:54:46 | ||||||||||||||||
scalar · DisplayString · read-write · mandatory The current time in the hh:mm:ss 24H format. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nmtrapinfo | 1.3.6.1.4.1.3808.2.2 | ||||||||||||||||||||
| SmtrapinfoInteger | 1.3.6.1.4.1.3808.2.2.1 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Allow CPS traps with an integer argument for providing detail information. Not being defined in the MIB, only reply 0. | |||||||||||||||||||||
| SmtrapinfoIpAddress | 1.3.6.1.4.1.3808.2.2.2 | IpAddress | RO | mandatory | |||||||||||||||||
scalar · IpAddress · read-only · mandatory Allow CPS traps with an IP address argument for providing detail information. Not being defined in the MIB, only reply 0.0.0.0. | |||||||||||||||||||||
| SmtrapinfoString | 1.3.6.1.4.1.3808.2.2.3 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Allow CPS traps with an octet string argument for providing detail information. Not being defined in the MIB, only reply a NULL string. | |||||||||||||||||||||
| SmtrapinfoGauge | 1.3.6.1.4.1.3808.2.2.4 | Gauge | RO | mandatory | |||||||||||||||||
scalar · Gauge · read-only · mandatory Allow CPS traps with an Gauge argument for providing detail information. Not being defined in the MIB, only reply 0. | |||||||||||||||||||||
| SmtrapinfoTimeTicks | 1.3.6.1.4.1.3808.2.2.5 | TimeTicks | RO | mandatory | |||||||||||||||||
scalar · TimeTicks · read-only · mandatory Allow CPS traps with an TimeTicks argument for providing detail information. Not being defined in the MIB, only reply 0. | |||||||||||||||||||||
| SmtrapinfoBmEventId | 1.3.6.1.4.1.3808.2.2.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Allow CPS traps with an integer argument for providing detail information about Battery Manager specific event identifier. Not being defined in the MIB, only reply 0. Known Specific Event ID: Battery Manager 0 - not used 1 - Alarm: The battery manager system fault. 2 - Info: Device configuration changed. 3 - Alarm: Probe configuration mismatched. 4 - Info: Probe configuration matched. 5 - Alarm: Communication with battery manager has been lost. 6 - Info: Communication with battery manager has been restored. 7 - Alarm: Communication with LCD has been lost. 8 - Info: Communication with LCD has been restored. 9 - Warning: Enter battery equalization active mode. 10- Warning: Leave battery equalization active mode. 11- Alarm: Battery equalizing has failed. 12- Info: Battery equalizing succeeds. 13- Warning: Enter BMS software operation mode. 14- Warning: Leave BMS software operatioin mode. 15- Warning: Authentication to the BMS software has been failed. 16- Alarm: Communication to the BMS software has been lost. 17- Info: Communication to the BMS software has restored. 18- Alarm: Communication with Wireless module has been lost. 19- Info: Communication with Wireless module has been restored. Known Specific Event ID: Battery Probes 101 - Alarm: Low battery voltage. 102 - Alarm: High battery voltage. 103 - Info: Battery voltage event has cleared. 104 - Alarm: Low battery temperature. 105 - Alarm: High battery temperature. 106 - Info: Battery temperature event has cleared. 107 - Alarm: Critical low battery resistance. 108 - Alarm: Critical high battery resistance. 109 - Warning: Low battery resistance. 110 - Warning: high battery resistance. 111 - Info: Battery resistance event has cleared. 112 - Alarm: Battery resistance health has crossed alarm threshold. 113 - Warning: Battery resistance health has crossed warning threshold. 114 - Info: Battery resistance health has returned to Normal. 115 - Alarm: Battery voltage has under the shutdown threshold for a time. 116 - Info: Battery voltage has restored from the shutdown threshold. 117 - Alarm: Battery probes has been shut down. 118 - Alarm: Low battery soc. 119 - Warning: Low battery soc. 120 - Info: Battery soc event has cleared. Known Specific Event ID: BM String Voltage 201 - Alarm: Low string voltage. 202 - Alarm: High string voltage. 203 - Warning: Low string voltage. 204 - Warning: High string voltage. 205 - Info: String voltage event has cleared. 226 - Alarm: Low string soc. 207 - Warning: Low string soc. 208 - Info: String soc event has cleared. Known Specific Event ID: BM Wireless 301 - Warning: Wireless sensors may incomplete, searching wireless sensors. 302 - Info: Wireless sensor has left the network. 303 - Info: Wireless sensor has joined the network. 304 - Info: Wireless sensors complete and communication normally. 305 - Warning: Communication with the wireless sensor has been losted. 306 - Info: Communication with the wireless sensor has been restored. 307 - Warning: Restart/Reset wireless neetwork. 308 - Info: Wireless network configuration changed. | |||||||||||||||||||||
| SmtrapinfoCpEventId | 1.3.6.1.4.1.3808.2.2.7 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Allow CPS traps with an integer argument for providing detail
information about Current Probe specific event identifier.
Not being defined in the MIB, only reply 0.
Known Specific Event ID: Current Probes
301 - Warning: Low charge current.
302 - Warning: High charge current.
303 - Alarm: Low charge current.
304 - Alarm: High charge current.
305 - Info: Charge current event has cleared.
306 - Warning: Low discharge current.
307 - Warning: High discharge current.
308 - Alarm: Low discharge current.
309 - Alarm: High discharge current.
310 - Info: Discharge current event has cleared.
311 - Warning: Low RMS current.
312 - Warning: High RMS current.
313 - Alarm: Low RMS current.
314 - Alarm: High RMS current.
315 - Info: RMS current event has cleared.
350 - Warning: Discharge.
351 - Alarm: Discharge.
352 - Info: Discharge event has cleared.
380 - Alarm: Number of current probe has decreased.
381 - Info: Number of current probe has increased.
382 - Info: Current probe configuration has been changed. | |||||||||||||||||||||
| Nmcontrol | 1.3.6.1.4.1.3808.2.3 | ||||||||||||||||||||
| SmcontrolRestart | 1.3.6.1.4.1.3808.2.3.1 | INTEGER | RW | mandatory | none(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this OID to restartCurrentSystem (2) will restart the current system. Setting this OID to restartCurrentAgent (3) will restart the current agent. Setting this OID to restartCurrentSystemAnd Agent (4) will restart the current system and agent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
| SmcontrolReset | 1.3.6.1.4.1.3808.2.3.2 | INTEGER | RW | mandatory | none(1) | ||||||||||||||||
scalar · INTEGER · read-write · mandatory Setting this OID to resetCurrentSystem (2) will reset the current system. Setting this OID to resetCurrentAgent (3) will reset the current agent. Setting this OID to resetCurrentSystemAndAgenta (4) will reset the current system and the current agent.
Example values from LibreNMS test devices
| |||||||||||||||||||||
Traps / Notifications
- accessoryDeviceAlarm
1.3.6.1.4.1.3808.0.251 - accessoryDeviceAlarmClear
1.3.6.1.4.1.3808.0.252 - accessoryDeviceEvent
1.3.6.1.4.1.3808.0.250 - adminLoginInfo
1.3.6.1.4.1.3808.0.65 - adminLogoutInfo
1.3.6.1.4.1.3808.0.66 - atsCancelPendingCommand
1.3.6.1.4.1.3808.0.337 - atsCommunicationEstablished
1.3.6.1.4.1.3808.0.315 - atsCommunicationLost
1.3.6.1.4.1.3808.0.314 - atsDB9CommunicationLost
1.3.6.1.4.1.3808.0.318 - atsDB9CommunicationLostCleared
1.3.6.1.4.1.3808.0.319 - atsDevHardwareFault
1.3.6.1.4.1.3808.0.322 - atsDevHardwareFaultCleared
1.3.6.1.4.1.3808.0.323 - atsDeviceConfigChanged
1.3.6.1.4.1.3808.0.325 - atsEventCountsCleared
1.3.6.1.4.1.3808.0.327 - atsInputHighFrequency
1.3.6.1.4.1.3808.0.310 - atsInputHighFrequencyCleared
1.3.6.1.4.1.3808.0.311 - atsInputHighVoltage
1.3.6.1.4.1.3808.0.306 - atsInputHighVoltageCleared
1.3.6.1.4.1.3808.0.307 - atsInputLowFrequency
1.3.6.1.4.1.3808.0.312 - atsInputLowFrequencyCleared
1.3.6.1.4.1.3808.0.313 - atsInputLowVoltage
1.3.6.1.4.1.3808.0.308 - atsInputLowVoltageCleared
1.3.6.1.4.1.3808.0.309 - atsLCDCommunicationLost
1.3.6.1.4.1.3808.0.316 - atsLCDCommunicationLostCleared
1.3.6.1.4.1.3808.0.317 - atsLowLoad
1.3.6.1.4.1.3808.0.332 - atsLowLoadCleared
1.3.6.1.4.1.3808.0.333 - atsNearOverload
1.3.6.1.4.1.3808.0.330 - atsNearOverloadCleared
1.3.6.1.4.1.3808.0.331 - atsOutletConfigChanged
1.3.6.1.4.1.3808.0.326 - atsOutletOff
1.3.6.1.4.1.3808.0.339 - atsOutletOffCommand
1.3.6.1.4.1.3808.0.335 - atsOutletOn
1.3.6.1.4.1.3808.0.338 - atsOutletOnCommand
1.3.6.1.4.1.3808.0.334 - atsOutletRebootCommand
1.3.6.1.4.1.3808.0.336 - atsOverload
1.3.6.1.4.1.3808.0.328 - atsOverloadCleared
1.3.6.1.4.1.3808.0.329 - atsPowerSupplyFault
1.3.6.1.4.1.3808.0.320 - atsPowerSupplyFaultCleared
1.3.6.1.4.1.3808.0.321 - atsRedundancyFail
1.3.6.1.4.1.3808.0.304 - atsRedundancyRestored
1.3.6.1.4.1.3808.0.305 - atsSourceConfigChanged
1.3.6.1.4.1.3808.0.324 - atsSourceFault
1.3.6.1.4.1.3808.0.302 - atsSourceFaultCleared
1.3.6.1.4.1.3808.0.303 - atsSwitchSource
1.3.6.1.4.1.3808.0.301 - bmProbesAlarm
1.3.6.1.4.1.3808.0.603 - bmProbesInfo
1.3.6.1.4.1.3808.0.605 - bmSProbesWarning
1.3.6.1.4.1.3808.0.604 - bmStringsAlarm
1.3.6.1.4.1.3808.0.606 - bmStringsInfo
1.3.6.1.4.1.3808.0.608 - bmStringsWarning
1.3.6.1.4.1.3808.0.607 - bmSystemAlarm
1.3.6.1.4.1.3808.0.600 - bmSystemInfo
1.3.6.1.4.1.3808.0.602 - bmSystemWarning
1.3.6.1.4.1.3808.0.601 - clientRegistered
1.3.6.1.4.1.3808.0.70 - clientRemoved
1.3.6.1.4.1.3808.0.71 - communicationEstablished
1.3.6.1.4.1.3808.0.8 - communicationLost
1.3.6.1.4.1.3808.0.1 - configFileUpload
1.3.6.1.4.1.3808.0.64 - configurationChanged
1.3.6.1.4.1.3808.0.69 - currProbesAlarm
1.3.6.1.4.1.3808.0.700 - currProbesInfo
1.3.6.1.4.1.3808.0.702 - currProbesWarning
1.3.6.1.4.1.3808.0.701 - deviceLoginInfo
1.3.6.1.4.1.3808.0.67 - deviceLogoutInfo
1.3.6.1.4.1.3808.0.68 - ePDUBankLowLoad
1.3.6.1.4.1.3808.0.124 - ePDUBankLowLoadCleared
1.3.6.1.4.1.3808.0.125 - ePDUBankNearOverload
1.3.6.1.4.1.3808.0.126 - ePDUBankNearOverloadCleared
1.3.6.1.4.1.3808.0.127 - ePDUBankOverload
1.3.6.1.4.1.3808.0.128 - ePDUBankOverloadCleared
1.3.6.1.4.1.3808.0.129 - ePDUCancelPendingCommand
1.3.6.1.4.1.3808.0.115 - ePDUCommunicationEstablished
1.3.6.1.4.1.3808.0.100 - ePDUCommunicationLost
1.3.6.1.4.1.3808.0.101 - ePDUComponentCommunicationEstablished
1.3.6.1.4.1.3808.0.130 - ePDUComponentCommunicationLost
1.3.6.1.4.1.3808.0.131 - ePDUDelayOutletOffCommand
1.3.6.1.4.1.3808.0.113 - ePDUDelayOutletOnCommand
1.3.6.1.4.1.3808.0.112 - ePDUDelayOutletRebootCommand
1.3.6.1.4.1.3808.0.114 - ePDUDeviceConfigChange
1.3.6.1.4.1.3808.0.104 - ePDULineOvervoltage
1.3.6.1.4.1.3808.0.118 - ePDULineOvervoltageCleared
1.3.6.1.4.1.3808.0.119 - ePDULineUndervoltage
1.3.6.1.4.1.3808.0.116 - ePDULineUndervoltageCleared
1.3.6.1.4.1.3808.0.117 - ePDULowLoad
1.3.6.1.4.1.3808.0.106 - ePDULowLoadCleared
1.3.6.1.4.1.3808.0.107 - ePDUNearOverload
1.3.6.1.4.1.3808.0.108 - ePDUNearOverloadCleared
1.3.6.1.4.1.3808.0.109 - ePDUOutletConfigChange
1.3.6.1.4.1.3808.0.105 - ePDUOutletLowLoad
1.3.6.1.4.1.3808.0.132 - ePDUOutletLowLoadCleared
1.3.6.1.4.1.3808.0.133 - ePDUOutletNearOverload
1.3.6.1.4.1.3808.0.134 - ePDUOutletNearOverloadCleared
1.3.6.1.4.1.3808.0.135 - ePDUOutletOff
1.3.6.1.4.1.3808.0.103 - ePDUOutletOn
1.3.6.1.4.1.3808.0.102 - ePDUOutletOverload
1.3.6.1.4.1.3808.0.136 - ePDUOutletOverloadCleared
1.3.6.1.4.1.3808.0.137 - ePDUOverload
1.3.6.1.4.1.3808.0.110 - ePDUOverloadCleared
1.3.6.1.4.1.3808.0.111 - ePDUPowerSupply1Fail
1.3.6.1.4.1.3808.0.120 - ePDUPowerSupply1Ok
1.3.6.1.4.1.3808.0.121 - ePDUPowerSupply2Fail
1.3.6.1.4.1.3808.0.122 - ePDUPowerSupply2Ok
1.3.6.1.4.1.3808.0.123 - envConntected
1.3.6.1.4.1.3808.0.210 - envContactAlarm
1.3.6.1.4.1.3808.0.260 - envContactAlarmClear
1.3.6.1.4.1.3808.0.261 - envContactEvent
1.3.6.1.4.1.3808.0.259 - envDisconntected
1.3.6.1.4.1.3808.0.211 - envDryContactAbnormal
1.3.6.1.4.1.3808.0.208 - envDryContactNormal
1.3.6.1.4.1.3808.0.209 - envHighHumidityBack
1.3.6.1.4.1.3808.0.205 - envHighHumidityViolation
1.3.6.1.4.1.3808.0.204 - envHighTemperatureBack
1.3.6.1.4.1.3808.0.201 - envHighTemperatureViolation
1.3.6.1.4.1.3808.0.200 - envHumidityAlarm
1.3.6.1.4.1.3808.0.257 - envHumidityAlarmClear
1.3.6.1.4.1.3808.0.258 - envHumidityEvent
1.3.6.1.4.1.3808.0.256 - envLowHumdBack
1.3.6.1.4.1.3808.0.207 - envLowHumidityViolation
1.3.6.1.4.1.3808.0.206 - envLowTempBack
1.3.6.1.4.1.3808.0.203 - envLowTemperatureViolation
1.3.6.1.4.1.3808.0.202 - envRateOfHumdChangeAbnormal
1.3.6.1.4.1.3808.0.213 - envRateOfTemperatureChangeAbnormal
1.3.6.1.4.1.3808.0.212 - envTemperatureAlarm
1.3.6.1.4.1.3808.0.254 - envTemperatureAlarmClear
1.3.6.1.4.1.3808.0.255 - envTemperatureEvent
1.3.6.1.4.1.3808.0.253 - failAuthViaConsole
1.3.6.1.4.1.3808.0.63 - failAuthViaHTTP
1.3.6.1.4.1.3808.0.61 - firmwareUpdateFail
1.3.6.1.4.1.3808.0.76 - firmwareUpdateSuccess
1.3.6.1.4.1.3808.0.75 - lowBattery
1.3.6.1.4.1.3808.0.7 - nclBankOff
1.3.6.1.4.1.3808.0.32 - nclBankOn
1.3.6.1.4.1.3808.0.31 - nclBankStartScheduleOff
1.3.6.1.4.1.3808.0.36 - outletUserLoginInfo
1.3.6.1.4.1.3808.0.73 - outletUserLogoutInfo
1.3.6.1.4.1.3808.0.74 - passwordChange
1.3.6.1.4.1.3808.0.62 - pduBankAlarm
1.3.6.1.4.1.3808.0.407 - pduBankAlarmClear
1.3.6.1.4.1.3808.0.408 - pduBankEvent
1.3.6.1.4.1.3808.0.406 - pduDaisyChainAlarm
1.3.6.1.4.1.3808.0.416 - pduDaisyChainAlarmClear
1.3.6.1.4.1.3808.0.417 - pduDaisyChainEvent
1.3.6.1.4.1.3808.0.415 - pduDeviceAlarm
1.3.6.1.4.1.3808.0.401 - pduDeviceAlarmClear
1.3.6.1.4.1.3808.0.402 - pduDeviceEvent
1.3.6.1.4.1.3808.0.400 - pduOutletMeteredAlarm
1.3.6.1.4.1.3808.0.413 - pduOutletMeteredAlarmClear
1.3.6.1.4.1.3808.0.414 - pduOutletMeteredEvent
1.3.6.1.4.1.3808.0.412 - pduOutletMonitoredEvent
1.3.6.1.4.1.3808.0.418 - pduOutletSwitchedAlarm
1.3.6.1.4.1.3808.0.410 - pduOutletSwitchedAlarmClear
1.3.6.1.4.1.3808.0.411 - pduOutletSwitchedEvent
1.3.6.1.4.1.3808.0.409 - pduPhaseAlarm
1.3.6.1.4.1.3808.0.404 - pduPhaseAlarmClear
1.3.6.1.4.1.3808.0.405 - pduPhaseEvent
1.3.6.1.4.1.3808.0.403 - pduSourceAlarm
1.3.6.1.4.1.3808.0.420 - pduSourceAlarmClear
1.3.6.1.4.1.3808.0.421 - pduSourceEvent
1.3.6.1.4.1.3808.0.419 - powerRestored
1.3.6.1.4.1.3808.0.9 - returnFromChargerFailure
1.3.6.1.4.1.3808.0.24 - returnFromDischarged
1.3.6.1.4.1.3808.0.20 - returnFromLowBattery
1.3.6.1.4.1.3808.0.11 - returnFromOverLoad
1.3.6.1.4.1.3808.0.19 - returnFromOverTemp
1.3.6.1.4.1.3808.0.17 - testEvent
1.3.6.1.4.1.3808.0.72 - upsAutoPingFail
1.3.6.1.4.1.3808.0.506 - upsAutoPingRecovery
1.3.6.1.4.1.3808.0.507 - upsBatteryExpiration
1.3.6.1.4.1.3808.0.49 - upsBatteryNotPresent
1.3.6.1.4.1.3808.0.39 - upsBatteryOverThreeYear
1.3.6.1.4.1.3808.0.48 - upsBatteryReplacement
1.3.6.1.4.1.3808.0.50 - upsBoostOn
1.3.6.1.4.1.3808.0.6 - upsBuckOn
1.3.6.1.4.1.3808.0.18 - upsBypassOverload
1.3.6.1.4.1.3808.0.44 - upsBypassOverloadCleared
1.3.6.1.4.1.3808.0.45 - upsCancelPendingCommand
1.3.6.1.4.1.3808.0.505 - upsChargerFailure
1.3.6.1.4.1.3808.0.23 - upsCommandCancel
1.3.6.1.4.1.3808.0.33 - upsDiagnosticsFailed
1.3.6.1.4.1.3808.0.3 - upsDiagnosticsPassed
1.3.6.1.4.1.3808.0.10 - upsDischarged
1.3.6.1.4.1.3808.0.4 - upsEmergencyPowerOff
1.3.6.1.4.1.3808.0.30 - upsEnterBypassMode
1.3.6.1.4.1.3808.0.42 - upsEnterECOMode
1.3.6.1.4.1.3808.0.46 - upsEnterSleep
1.3.6.1.4.1.3808.0.22 - upsEstimationAbort
1.3.6.1.4.1.3808.0.37 - upsFirmwareUpgradeEnd
1.3.6.1.4.1.3808.0.57 - upsFirmwareUpgradeStart
1.3.6.1.4.1.3808.0.56 - upsHardwareFault
1.3.6.1.4.1.3808.0.38 - upsLostRedundant
1.3.6.1.4.1.3808.0.28 - upsModuleFanAlarm
1.3.6.1.4.1.3808.0.53 - upsModuleInvertorAlarm
1.3.6.1.4.1.3808.0.51 - upsModuleManualShutdown
1.3.6.1.4.1.3808.0.54 - upsModuleOverload
1.3.6.1.4.1.3808.0.55 - upsModuleRectifierAlarm
1.3.6.1.4.1.3808.0.52 - upsOnBattery
1.3.6.1.4.1.3808.0.5 - upsOutletOff
1.3.6.1.4.1.3808.0.501 - upsOutletOffCommand
1.3.6.1.4.1.3808.0.503 - upsOutletOn
1.3.6.1.4.1.3808.0.500 - upsOutletOnCommand
1.3.6.1.4.1.3808.0.502 - upsOutletRebootCommand
1.3.6.1.4.1.3808.0.504 - upsOverTemp
1.3.6.1.4.1.3808.0.16 - upsOverload
1.3.6.1.4.1.3808.0.2 - upsRFC1628TrapAlarmEntryAdded
1.3.6.1.4.1.3808.0.60 - upsRFC1628TrapOnBattery
1.3.6.1.4.1.3808.0.58 - upsRFC1628TrapTestCompleted
1.3.6.1.4.1.3808.0.59 - upsRebootStarted
1.3.6.1.4.1.3808.0.15 - upsRemainRuntimeLowThanThreshold
1.3.6.1.4.1.3808.0.35 - upsRemoteCommandFailed
1.3.6.1.4.1.3808.0.27 - upsReturnFromBypassMode
1.3.6.1.4.1.3808.0.43 - upsReturnFromECOMode
1.3.6.1.4.1.3808.0.47 - upsScheduleShutdown
1.3.6.1.4.1.3808.0.21 - upsSignalClientShutdown
1.3.6.1.4.1.3808.0.29 - upsSleeping
1.3.6.1.4.1.3808.0.13 - upsStartBatteryTest
1.3.6.1.4.1.3808.0.34 - upsTurnedOff
1.3.6.1.4.1.3808.0.12 - upsTurnedOn
1.3.6.1.4.1.3808.0.26 - upsTurnoffStarted
1.3.6.1.4.1.3808.0.25 - upsWiringFault
1.3.6.1.4.1.3808.0.40 - upsWiringFaultCleared
1.3.6.1.4.1.3808.0.41 - upsWokeUp
1.3.6.1.4.1.3808.0.14