WIPIPE-MIB
CradlePoint, Inc.snmptranslate -m WIPIPE-MIB -Tpsnmpwalk -v2c -c <community> -m WIPIPE-MIB <host> 1.3.6.1.4.1.20992Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Nwipipe | 1.3.6.1.4.1.20992 | |||
| NwipipeMgmt | 1.3.6.1.4.1.20992.1 | |||
| NwipipeDevice | 1.3.6.1.4.1.20992.1.1 | |||
| SdevFWVersion | 1.3.6.1.4.1.20992.1.1.1 | DisplayString (SIZE (0..255)) | RO | mandatory |
scalar · DisplayString (SIZE (0..255)) · read-only · mandatory A textual description providing the firmware version currently running on the device. It is mandatory that this only contain printable ASCII characters. @GET-FUNC=snmp_get_devFWVersion | ||||
| SdevFWUpgrade | 1.3.6.1.4.1.20992.1.1.2 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Initiate a FW upgrade on the device.
none - No upgrade is being performed or initiated.
auto - If no other upgrade is begin performed, when this value
is written then an automatic upgrade will be performed.
When an automatic upgrade is done then the device will
pull the most current FW image from the Wipipe server
and install it.
If this value is read then the router is performing an
automatic upgrade and the devFWUpgradeStatus object should
be read for further information.
manual - If no other upgrade is begin performed, when this value
is written then a manual upgrade will be performed.
When an manual upgrade is done it will use the URL set
in the devFWUpgradeURL object as the place to get the
firmware image and install. If the devFWUpgradeURL object
is not set then no upgrade will be performed.
If this value is read then the router is performing an
manual upgrade and the devFWUpgradeStatus object should
be read for further information. -
@SET-FUNC=snmp_set_devFWUpgrade
@GET-FUNC=snmp_get_devFWUpgrade
| ||||
| SdevFWUpgradeURL | 1.3.6.1.4.1.20992.1.1.3 | DisplayString (SIZE (0..255)) | RW | mandatory |
scalar · DisplayString (SIZE (0..255)) · read-write · mandatory Set the URL that points to the firmware image that will be used when doing a manual firmware upgrade. @SET-FUNC=snmp_set_devFWUpgradeURL @GET-FUNC=snmp_get_devFWUpgradeURL | ||||
| SdevFWUpgradeStatus | 1.3.6.1.4.1.20992.1.1.4 | INTEGER | RO | mandatory |
scalar · INTEGER · read-only · mandatory Show the result of the FW upgrade command. idle = there is no upgrade in process. upgrading = the new FW is being downloaded and written to flash. uptodate = the device is already at the latest FW. Nothing to upgrade. updateAvail - the device has an automatic update available. failure = some sort of failure occurred during the upgrade. The FW will not be upgraded. NOTE - while the FW image is being written to flash interrupts are disabled so no status will be returned at this time. User should get the FW version string in order to determine if the unit has been updated successfully. @GET-FUNC=snmp_get_devFWUpgradeStatus
| ||||
| SdevGpioConfigInput | 1.3.6.1.4.1.20992.1.1.5 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Set the Input GPIO config on the connector.
none - ignore input value.
input - read the input value.
reboot - if the input is held low for 10 seconds,
reboot the router.
ignition_sensing - if the input is held low for 300 seconds,
power off the router. IBR11x0 series feature.
@SET-FUNC=snmp_set_devGpioConfigInput
@GET-FUNC=snmp_get_devGpioConfigInput
| ||||
| SdevGpioReadInput | 1.3.6.1.4.1.20992.1.1.6 | INTEGER (0..1) | RO | mandatory |
scalar · INTEGER (0..1) · read-only · mandatory Read the Input GPIO value on the connector. 0 - low. 1 - high. @SET-FUNC=snmp_set_devGpioReadInput @GET-FUNC=snmp_get_devGpioReadInput | ||||
| SdevGpioConfigOutput | 1.3.6.1.4.1.20992.1.1.7 | INTEGER | RW | mandatory |
scalar · INTEGER · read-write · mandatory Set the output GPIO config on the connector.
low - Default low output value.
high - high output value.
routerRunning - high output value once the router completes
its boot process.
modemConnected - high output value when the modem completes a
data connection
@SET-FUNC=snmp_set_devGpioConfigOutput
@GET-FUNC=snmp_get_devGpioConfigOutput
| ||||
| SdevGpioReadOutput | 1.3.6.1.4.1.20992.1.1.8 | INTEGER (0..1) | RO | mandatory |
scalar · INTEGER (0..1) · read-only · mandatory Read the Output GPIO value on the connector. 0 - low. 1 - high. @SET-FUNC=snmp_set_devGpioReadOutput @GET-FUNC=snmp_get_devGpioReadOutput | ||||
| NwipipeCellMdm | 1.3.6.1.4.1.20992.1.2 | |||
| SmdmNumber | 1.3.6.1.4.1.20992.1.2.1 | INTEGER (0..10) | RO | mandatory |
scalar · INTEGER (0..10) · read-only · mandatory The number of Cellular Modems (regardless of their current state) present on this system. @GET-FUNC=snmp_get_mdmNumber | ||||
| TmdmTable | 1.3.6.1.4.1.20992.1.2.2 | NA | mandatory | |
table · not-accessible · mandatory A list of Modem entries. The number of entries is given by the value of ifNumber. | ||||
| RmdmEntry | 1.3.6.1.4.1.20992.1.2.2.1 | NA | mandatory | |
row · not-accessible · mandatory An entry containing management information applicable to a particular modem. @ROW-FUNC=snmp_get_mdmTable_row
| ||||
| CmdmIndex | 1.3.6.1.4.1.20992.1.2.2.1.1 | INTEGER (0..10) | RO | mandatory |
column · INTEGER (0..10) · read-only · mandatory A unique value, greater than zero, for each cellular modem. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization. | ||||
| CmdmDescr | 1.3.6.1.4.1.20992.1.2.2.1.2 | DisplayString (SIZE (0..255)) | RO | mandatory |
column · DisplayString (SIZE (0..255)) · read-only · mandatory A textual string containing information about the modem. | ||||
| CmdmPort | 1.3.6.1.4.1.20992.1.2.2.1.3 | DisplayString (SIZE (0..255)) | RO | mandatory |
column · DisplayString (SIZE (0..255)) · read-only · mandatory A textual string containing information about what port the modem is installed in. | ||||
| CmdmSignalStrength | 1.3.6.1.4.1.20992.1.2.2.1.4 | INTEGER (-120..-30) | RO | mandatory |
column · INTEGER (-120..-30) · read-only · mandatory The cellular modems signal strength, given in dBm's. | ||||
| CmdmStatus | 1.3.6.1.4.1.20992.1.2.2.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory A textual string containing infomation of the state of the modem.
| ||||
| CmdmECIO | 1.3.6.1.4.1.20992.1.2.2.1.6 | INTEGER (-120..0) | RO | mandatory |
column · INTEGER (-120..0) · read-only · mandatory The cellular modems Ec/Io ratio given in dBm's. | ||||
| CmdmSerialNumber | 1.3.6.1.4.1.20992.1.2.2.1.7 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory A textual string representing the unique serial number of the device. | ||||
| CmdmFirmwareVersion | 1.3.6.1.4.1.20992.1.2.2.1.8 | DisplayString (SIZE (0..64)) | RO | mandatory |
column · DisplayString (SIZE (0..64)) · read-only · mandatory A textual string representing the current firmware version of the modem. Not all modems report this value. | ||||
| CmdmMDN | 1.3.6.1.4.1.20992.1.2.2.1.9 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory A textual string representing the unique Mobile Directory Number of the device. | ||||
| CmdmSERDIS | 1.3.6.1.4.1.20992.1.2.2.1.10 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory A textual string representing the Service Display of the device. | ||||
| CmdmPROF | 1.3.6.1.4.1.20992.1.2.2.1.11 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory A textual string representing the Profile of the device. | ||||
| CmdmCINR | 1.3.6.1.4.1.20992.1.2.2.1.12 | INTEGER (-120..0) | RO | mandatory |
column · INTEGER (-120..0) · read-only · mandatory The cellular modems CINR ratio given in dBm's. | ||||
| CmdmSINR | 1.3.6.1.4.1.20992.1.2.2.1.13 | INTEGER (-20..40) | RO | mandatory |
column · INTEGER (-20..40) · read-only · mandatory The cellular modems SINR ratio given in dBm's. | ||||
| CmdmRSRP | 1.3.6.1.4.1.20992.1.2.2.1.14 | INTEGER (-120..100) | RO | mandatory |
column · INTEGER (-120..100) · read-only · mandatory The cellular modems RSRP given in dBm's. | ||||
| CmdmRSRQ | 1.3.6.1.4.1.20992.1.2.2.1.15 | INTEGER (-120..50) | RO | mandatory |
column · INTEGER (-120..50) · read-only · mandatory The cellular modems RSRQ given in dBm's. | ||||
| CmdmROAM | 1.3.6.1.4.1.20992.1.2.2.1.16 | INTEGER (0..2) | RO | mandatory |
column · INTEGER (0..2) · read-only · mandatory The cellular modems Roaming Status. | ||||
| CmdmRFBAND | 1.3.6.1.4.1.20992.1.2.2.1.17 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory The cellular modems RF band. | ||||
| CmdmHOMECARRIER | 1.3.6.1.4.1.20992.1.2.2.1.18 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory The cellular modems Home Carrier. | ||||
| CmdmIMSI | 1.3.6.1.4.1.20992.1.2.2.1.19 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory The cellular modems IMSI. | ||||
| CmdmIMEI | 1.3.6.1.4.1.20992.1.2.2.1.20 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory The cellular modems IMEI. | ||||
| CmdmAPN | 1.3.6.1.4.1.20992.1.2.2.1.21 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory The cellular modems APN. | ||||
| CmdmRFCHANNEL | 1.3.6.1.4.1.20992.1.2.2.1.22 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory The cellular modems RF Channel. | ||||
| NwipipeProd | 1.3.6.1.4.1.20992.2 | |||
| Nmbr1000 | 1.3.6.1.4.1.20992.2.1 | |||
| Nctr500 | 1.3.6.1.4.1.20992.2.2 | |||
| Nmbr800 | 1.3.6.1.4.1.20992.2.3 | |||
| Nmbr1100 | 1.3.6.1.4.1.20992.2.4 | |||
| Nmbr1200 | 1.3.6.1.4.1.20992.2.5 | |||
| Nmbr900 | 1.3.6.1.4.1.20992.2.6 | |||
| Ncba250 | 1.3.6.1.4.1.20992.2.7 | |||
| Ncba750 | 1.3.6.1.4.1.20992.2.8 | |||
| Ncx111 | 1.3.6.1.4.1.20992.2.9 | |||
| Nmbr1400 | 1.3.6.1.4.1.20992.2.10 | |||
| Nmbr1200b | 1.3.6.1.4.1.20992.2.11 | |||
| Ncbr400 | 1.3.6.1.4.1.20992.2.12 | |||
| Ncbr450 | 1.3.6.1.4.1.20992.2.13 | |||
| Nibr600 | 1.3.6.1.4.1.20992.2.14 | |||
| Nibr650 | 1.3.6.1.4.1.20992.2.15 | |||
| Nmbr1400v2 | 1.3.6.1.4.1.20992.2.16 | |||
| Ncba750b | 1.3.6.1.4.1.20992.2.17 | |||
| Naer2100 | 1.3.6.1.4.1.20992.2.18 | |||
| Nibr1150 | 1.3.6.1.4.1.20992.2.19 | |||
| Nibr1100 | 1.3.6.1.4.1.20992.2.20 | |||
| Ncba850 | 1.3.6.1.4.1.20992.2.21 | |||
| Nibr350 | 1.3.6.1.4.1.20992.2.22 | |||
| Naer3100 | 1.3.6.1.4.1.20992.2.23 | |||
| Naer1600 | 1.3.6.1.4.1.20992.2.24 | |||
| Nibr650b | 1.3.6.1.4.1.20992.2.25 | |||
| Naer3150 | 1.3.6.1.4.1.20992.2.26 | |||
| Naer1650 | 1.3.6.1.4.1.20992.2.27 | |||
| Naer2150 | 1.3.6.1.4.1.20992.2.28 | |||
| Nibr600b | 1.3.6.1.4.1.20992.2.29 | |||
| Nibr950 | 1.3.6.1.4.1.20992.2.30 | |||
| Nibr900 | 1.3.6.1.4.1.20992.2.31 | |||