HH3C-TRANSCEIVER-INFO-MIB
H3CAdd hh3cTransceiverTotalTXPower and hh3cTransceiverTotalRXPower.
snmptranslate -m HH3C-TRANSCEIVER-INFO-MIB -Tpsnmpwalk -v2c -c <community> -m HH3C-TRANSCEIVER-INFO-MIB <host> 1.3.6.1.4.1.25506.2.70Imports
| HH3C-OID-MIB | hh3cCommon |
|---|---|
| IF-MIB | ifIndex, ifName |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ihh3cTransceiver | 1.3.6.1.4.1.25506.2.70 | ||||||||||||||||||||
identity Add hh3cTransceiverTotalTXPower and hh3cTransceiverTotalRXPower. | |||||||||||||||||||||
| Nhh3cTransceiverInfoAdm | 1.3.6.1.4.1.25506.2.70.1 | ||||||||||||||||||||
| Thh3cTransceiverInfoTable | 1.3.6.1.4.1.25506.2.70.1.1 | NA | |||||||||||||||||||
table · not-accessible · current This table shows transceiver information on an interface. | |||||||||||||||||||||
| Rhh3cTransceiverInfoEntry | 1.3.6.1.4.1.25506.2.70.1.1.1 | NA | |||||||||||||||||||
| Chh3cTransceiverHardwareType | 1.3.6.1.4.1.25506.2.70.1.1.1.1 | OCTET STRING | RO | SM | |||||||||||||||||
| Chh3cTransceiverType | 1.3.6.1.4.1.25506.2.70.1.1.1.2 | OCTET STRING | RO | 1000_BASE_LX_SFP | |||||||||||||||||
column · OCTET STRING · read-only · current Type of the interface, such as SFP/XFP/GBIC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverWaveLength | 1.3.6.1.4.1.25506.2.70.1.1.1.3 | Integer32 | RO | 1310 | |||||||||||||||||
column · Integer32 · read-only · current Wave length of the interface, measured in nanometer. The unit is nm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverVendorName | 1.3.6.1.4.1.25506.2.70.1.1.1.4 | OCTET STRING | RO | HP | |||||||||||||||||
| Chh3cTransceiverSerialNumber | 1.3.6.1.4.1.25506.2.70.1.1.1.5 | OCTET STRING | RO | CN2AFSQ331 | |||||||||||||||||
| Chh3cTransceiverFiberDiameterType | 1.3.6.1.4.1.25506.2.70.1.1.1.6 | INTEGER | RO | fiber9(1) | |||||||||||||||||
column · INTEGER · read-only · current The diameter of the fiber, measured in micron. fiber9 - 9 micron multi-mode fiber fiber50 - 50 micron multi-mode fiber fiber625 - 62.5 micron multi-mode fiber copper - copper cable.
| |||||||||||||||||||||
| Chh3cTransceiverTransferDistance | 1.3.6.1.4.1.25506.2.70.1.1.1.7 | Integer32 | RO | 10000 | |||||||||||||||||
| Chh3cTransceiverDiagnostic | 1.3.6.1.4.1.25506.2.70.1.1.1.8 | TruthValue | RO | 1 | |||||||||||||||||
| Chh3cTransceiverCurTXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.9 | Integer32 | RO | -541 | |||||||||||||||||
| Chh3cTransceiverMaxTXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.10 | Integer32 | RO | -300 | |||||||||||||||||
| Chh3cTransceiverMinTXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.11 | Integer32 | RO | -950 | |||||||||||||||||
| Chh3cTransceiverCurRXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.12 | Integer32 | RO | -1005 | |||||||||||||||||
| Chh3cTransceiverMaxRXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.13 | Integer32 | RO | -300 | |||||||||||||||||
column · Integer32 · read-only · current Indicating the maximum received power. The unit is in hundredths of dBm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverMinRXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.14 | Integer32 | RO | -2000 | |||||||||||||||||
| Chh3cTransceiverTemperature | 1.3.6.1.4.1.25506.2.70.1.1.1.15 | Integer32 | RO | 31 | |||||||||||||||||
| Chh3cTransceiverVoltage | 1.3.6.1.4.1.25506.2.70.1.1.1.16 | Integer32 | RO | 331 | |||||||||||||||||
| Chh3cTransceiverBiasCurrent | 1.3.6.1.4.1.25506.2.70.1.1.1.17 | Integer32 | RO | 999 | |||||||||||||||||
| Chh3cTransceiverTempHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.18 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver temperature high alarm threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverTempLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.19 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver temperature low alarm threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverTempHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.20 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver temperature high warning threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverTempLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.21 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver temperature low warning threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverVccHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.22 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver VCC high alarm threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverVccLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.23 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver VCC low alarm threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverVccHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.24 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver VCC high warning threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverVccLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.25 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver VCC low warning threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverBiasHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.26 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver bias high alarm threshold in microamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverBiasLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.27 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver bias low alarm threshold in microamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverBiasHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.28 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver bias high warning threshold in microamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverBiasLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.29 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver bias low warning threshold in microamps. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverPwrOutHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.30 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power high alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverPwrOutLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.31 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power low alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverPwrOutHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.32 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power high warning threshold in tenths of microwatts As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverPwrOutLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.33 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power low warning threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverRcvPwrHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.34 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power high alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverRcvPwrLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.35 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power low alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverRcvPwrHiWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.36 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power high warning threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverRcvPwrLoWarn | 1.3.6.1.4.1.25506.2.70.1.1.1.37 | Integer32 | RO | 0 | |||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power low warning threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverErrors | 1.3.6.1.4.1.25506.2.70.1.1.1.38 | Bits | RO | 40 00 00 1 | |||||||||||||||||
column · Bits · read-only · current Bitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) TEC error(17) Wavelength unlocked(18) Tx is not ready due to tuning(19) Unused(20-31)
Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverVendorOUI | 1.3.6.1.4.1.25506.2.70.1.1.1.39 | OCTET STRING (SIZE (0..255)) | RO | 00:00:7f | |||||||||||||||||
column · OCTET STRING (SIZE (0..255)) · read-only · current Vendor OUI of the interface. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverRevisionNumber | 1.3.6.1.4.1.25506.2.70.1.1.1.40 | OCTET STRING (SIZE (0..255)) | RO | U*** | |||||||||||||||||
column · OCTET STRING (SIZE (0..255)) · read-only · current Revision number of the interface. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Chh3cTransceiverFrequency | 1.3.6.1.4.1.25506.2.70.1.1.1.41 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The frequency of the current ITU channel on the connected transceiver. The unit is hundredths of THz. | |||||||||||||||||||||
| Chh3cTransceiverActiveITUChannel | 1.3.6.1.4.1.25506.2.70.1.1.1.42 | Unsigned32 (1..4294967295) | RW | ||||||||||||||||||
column · Unsigned32 (1..4294967295) · read-write · current The index of the current ITU channel on the connected transceiver. The maximum index number for the ITU channel might vary by transceiver model. The value of this node depends on the hh3cTransceiverITUChanIdx node of hh3cTransceiverITUChanTable. The value of this node affects the frequency or wavelength. | |||||||||||||||||||||
| Chh3cTransceiverCurWaveErr | 1.3.6.1.4.1.25506.2.70.1.1.1.43 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The current wavelength error of the current ITU channel on the connected transceiver. The unit is thousandths of nm. | |||||||||||||||||||||
| Chh3cTransceiverWaveErrHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.44 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The high wavelength error alarm threshold of the current ITU channel on the connected transceiver. The unit is thousandths of nm. | |||||||||||||||||||||
| Chh3cTransceiverWaveErrLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.45 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The low wavelength error alarm threshold of the current ITU channel on the connected transceiver. The unit is thousandths of nm. | |||||||||||||||||||||
| Chh3cTransceiverCurFreqErr | 1.3.6.1.4.1.25506.2.70.1.1.1.46 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The current frequency error of the current ITU channel on the connected transceiver. The unit is tenths of GHz. | |||||||||||||||||||||
| Chh3cTransceiverFreqErrHiAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.47 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The high frequency error alarm threshold of the current ITU channel on the connected transceiver. The unit is tenths of GHz. | |||||||||||||||||||||
| Chh3cTransceiverFreqErrLoAlarm | 1.3.6.1.4.1.25506.2.70.1.1.1.48 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The low frequency error alarm threshold of the current ITU channel on the connected transceiver. The unit is tenths of GHz. | |||||||||||||||||||||
| Chh3cTransceiverPartNumber | 1.3.6.1.4.1.25506.2.70.1.1.1.49 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current PartNumber of the interface. As an example: 1110409083. | |||||||||||||||||||||
| Chh3cTransceiverProductCode | 1.3.6.1.4.1.25506.2.70.1.1.1.50 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Product Code of the interface. As an example: MRC00CD. | |||||||||||||||||||||
| Chh3cTransceiverOriginalSN | 1.3.6.1.4.1.25506.2.70.1.1.1.51 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Orginal serial number of the interface. | |||||||||||||||||||||
| Chh3cTransceiverPwrOutHiAlarmDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.52 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power high alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverPwrOutLoAlarmDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.53 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power low alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverPwrOutHiWarnDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.54 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power high warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverPwrOutLoWarnDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.55 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power low warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverRcvPwrHiAlarmDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.56 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power high alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverRcvPwrLoAlarmDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.57 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power low alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverRcvPwrHiWarnDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.58 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power high warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverRcvPwrLoWarnDbm | 1.3.6.1.4.1.25506.2.70.1.1.1.59 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver receive power low warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms. | |||||||||||||||||||||
| Chh3cTransceiverRelySlotMfgName | 1.3.6.1.4.1.25506.2.70.1.1.1.60 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Vendor name of the card on which the transceiver is installed. | |||||||||||||||||||||
| Chh3cTransceiverRelySlotMfgDate | 1.3.6.1.4.1.25506.2.70.1.1.1.61 | DateAndTime | RO | ||||||||||||||||||
column · DateAndTime · read-only · current Manufacturing date of the card on which the transceiver is installed. | |||||||||||||||||||||
| Chh3cTransceiverCurrentPower | 1.3.6.1.4.1.25506.2.70.1.1.1.62 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Current transceiver real-time power. The unit is thousandths of w. | |||||||||||||||||||||
| Chh3cTransceiverMaxPower | 1.3.6.1.4.1.25506.2.70.1.1.1.63 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Current transceiver maximum power. The unit is thousandths of w. | |||||||||||||||||||||
| Chh3cTransceiverTotalTXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.64 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Indicating the total transmitted power. The unit is in hundredths of dBm. | |||||||||||||||||||||
| Chh3cTransceiverTotalRXPower | 1.3.6.1.4.1.25506.2.70.1.1.1.65 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Indicating the total received power. The unit is in hundredths of dBm. | |||||||||||||||||||||
| Thh3cTransceiverChannelTable | 1.3.6.1.4.1.25506.2.70.1.2 | NA | |||||||||||||||||||
table · not-accessible · current This table provides statistics about transceiver with multi-channel. | |||||||||||||||||||||
| Rhh3cTransceiverChannelEntry | 1.3.6.1.4.1.25506.2.70.1.2.1 | NA | |||||||||||||||||||
row · not-accessible · current The entry of the hh3cTransceiverChannelTable. | |||||||||||||||||||||
| Chh3cTransceiverChannelIndex | 1.3.6.1.4.1.25506.2.70.1.2.1.1 | Integer32 (1..2147483647) | NA | ||||||||||||||||||
column · Integer32 (1..2147483647) · not-accessible · current The channel index of transceiver. Indicating one channel of the interface. | |||||||||||||||||||||
| Chh3cTransceiverChannelCurTXPower | 1.3.6.1.4.1.25506.2.70.1.2.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Indicating the current transmission power. The unit is in hundredths of dBm. | |||||||||||||||||||||
| Chh3cTransceiverChannelCurRXPower | 1.3.6.1.4.1.25506.2.70.1.2.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Indicating the current received power. The unit is in hundredths of dBm. | |||||||||||||||||||||
| Chh3cTransceiverChannelTemperature | 1.3.6.1.4.1.25506.2.70.1.2.1.4 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Indicating the current temperature. The unit is Celsius centigrade. | |||||||||||||||||||||
| Chh3cTransceiverChannelBiasCurrent | 1.3.6.1.4.1.25506.2.70.1.2.1.5 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Indicating the current bias electric current. The unit is in hundredths of mA. | |||||||||||||||||||||
| Chh3cTransceiverChannelBiasHiAm | 1.3.6.1.4.1.25506.2.70.1.2.1.6 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver bias high alarm threshold in microamps. | |||||||||||||||||||||
| Chh3cTransceiverChannelBiasLoAm | 1.3.6.1.4.1.25506.2.70.1.2.1.7 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver bias low alarm threshold in microamps. | |||||||||||||||||||||
| Chh3cTransceiverChannelTXPwrHiAm | 1.3.6.1.4.1.25506.2.70.1.2.1.8 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power high alarm threshold in tenths of microwatts. | |||||||||||||||||||||
| Chh3cTransceiverChannelTXPwrLoAm | 1.3.6.1.4.1.25506.2.70.1.2.1.9 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power low alarm threshold in tenths of microwatts. | |||||||||||||||||||||
| Chh3cTransceiverChanTXPwrHiAmDbm | 1.3.6.1.4.1.25506.2.70.1.2.1.10 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power high alarm threshold in hundredths of dBm. | |||||||||||||||||||||
| Chh3cTransceiverChanTXPwrLoAmDbm | 1.3.6.1.4.1.25506.2.70.1.2.1.11 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current Transceiver transmit power low alarm threshold in hundredths of dBm. | |||||||||||||||||||||
| Thh3cTransceiverITUChanTable | 1.3.6.1.4.1.25506.2.70.1.3 | NA | |||||||||||||||||||
table · not-accessible · current This table provides information about ITU channels supported on the transceiver that is connected to this interface. | |||||||||||||||||||||
| Rhh3cTransceiverITUChanEntry | 1.3.6.1.4.1.25506.2.70.1.3.1 | NA | |||||||||||||||||||
row · not-accessible · current The entry of the hh3cTransceiverITUChanTable. | |||||||||||||||||||||
| Chh3cTransceiverITUChanIdx | 1.3.6.1.4.1.25506.2.70.1.3.1.1 | Unsigned32 (1..4294967295) | NA | ||||||||||||||||||
column · Unsigned32 (1..4294967295) · not-accessible · current The index of the specified ITU channel on the transceiver that is connected to this interface. | |||||||||||||||||||||
| Chh3cTransceiverITUChanFreq | 1.3.6.1.4.1.25506.2.70.1.3.1.2 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The frequency of the specified ITU channel on the transceiver that is connected to this interface. The unit is hundredths of THz. | |||||||||||||||||||||
| Chh3cTransceiverITUChanWaveLth | 1.3.6.1.4.1.25506.2.70.1.3.1.3 | Integer32 | RO | ||||||||||||||||||
column · Integer32 · read-only · current The wave length of the specified ITU channel on the transceiver that is connected to this interface. The unit is pm. | |||||||||||||||||||||
| Thh3cTransceiverLaneTable | 1.3.6.1.4.1.25506.2.70.1.4 | NA | |||||||||||||||||||
table · not-accessible · current This table provides statistics about transceiver . | |||||||||||||||||||||
| Rhh3cTransceiverLaneEntry | 1.3.6.1.4.1.25506.2.70.1.4.1 | NA | |||||||||||||||||||
| Chh3cTransceiverLaneCurTxPower | 1.3.6.1.4.1.25506.2.70.1.4.1.1 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Indicating the current transmitted power. The unit is in hundredths of dBm. | |||||||||||||||||||||
| Chh3cTransceiverLaneCurRxPower | 1.3.6.1.4.1.25506.2.70.1.4.1.2 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Indicating the current received power. The unit is in hundredths of dBm. | |||||||||||||||||||||
| Chh3cTransceiverLaneBiasCurrent | 1.3.6.1.4.1.25506.2.70.1.4.1.3 | OCTET STRING | RO | ||||||||||||||||||
column · OCTET STRING · read-only · current Indicating the current bias electric current. The unit is in hundredths of mA. | |||||||||||||||||||||
| Nhh3cTransceiverSystemPara | 1.3.6.1.4.1.25506.2.70.2 | ||||||||||||||||||||
| Shh3cTransceiverExtrAlarmEnable | 1.3.6.1.4.1.25506.2.70.2.1 | TruthValue | RW | ||||||||||||||||||
scalar · TruthValue · read-write · current Enable alarming upon detection of a third-party transceiver. | |||||||||||||||||||||
| Shh3cTransceiverCurrentTotalPower | 1.3.6.1.4.1.25506.2.70.2.2 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Current transceivers real-time total power. The unit is thousandths of w. | |||||||||||||||||||||
| Shh3cTransceiverMaxTotalPower | 1.3.6.1.4.1.25506.2.70.2.3 | Integer32 | RO | ||||||||||||||||||
scalar · Integer32 · read-only · current Current transceivers maximum total power. The unit is thousandths of w. | |||||||||||||||||||||
| Nhh3cTransceiverTrap | 1.3.6.1.4.1.25506.2.70.3 | ||||||||||||||||||||
| Nhh3cTransceiverTrapPrefix | 1.3.6.1.4.1.25506.2.70.3.0 | ||||||||||||||||||||
| !hh3cTransceiverMaybeFake | 1.3.6.1.4.1.25506.2.70.3.0.1 | ||||||||||||||||||||
notification · current The transceiver is suspected to be a counterfeit/pirated/unauthorized transceiver. | |||||||||||||||||||||
Traps / Notifications
- hh3cTransceiverMaybeFake
1.3.6.1.4.1.25506.2.70.3.0.1