DomainId Integer32 (1..239)The Domain Id of the switch. This is assigned
dynamically if the Domain Manager is enabled on
the switch or could be configured statically by
the user.
DomainIdOrZero Integer32 (0..239)The Textual convention is an extension to
textual convetion 'DomainId'. It includes
the value '0'in addition the range 1-239.
Value '0' indicates that Domain Id has
been neither configured nor assigned.
FcAddress OCTET STRING (SIZE (3 | 8))Represents either the Fibre Channel Address ID or
the World Wide Name associated with a Fibre
Channel (FC) Entity.
FcAddressId OCTET STRING (SIZE (3))Represents Fibre Channel Address ID, a 24-bit
value unique within the address space of a Fabric.
FcAddressType INTEGERfcid(2) wwn(1)
Denotes if a Fibre Channel Address is
a World Wide Name (WWN) or a Fibre
Channel Address ID (FCID).
wwn(1) - address is WWN.
fcid(2) - address is FCID.
FcClassOfServices Bitsclass1(1) class2(2) class3(3) class4(4) class5(5) class6(6) classF(0)
Represents the class of service capability of an
NxPort or FxPort.
FcIfServiceStateType INTEGERinService(1) outOfService(2)
Represents the service state of a Fibre Channel
interface. Following are the meanings of the
enumerated values:
inService (1) - interface is in service and is
allowed to become operational.
outOfService (2) - interface is removed from service
and is not allowed to become
operational.FcIfSfpDiagLevelType INTEGERhighAlarm(6) highWarning(5) lowAlarm(4) lowWarning(3) normal(2) unknown(1)
Represents the severity level of the SFP
diagnostic information of an interface for
temperature, voltage, current, optical
transmit and receive power.
FcIfSpeed INTEGERauto(1) autoMaxEightG(9) autoMaxFourG(7) autoMaxSixteenG(11) autoMaxSixtyFourG(16) autoMaxThirtyTwoG(13) autoMaxTwoG(5) eightG(6) fiftyG(14) fourG(4) oneG(2) sixteenG(10) sixtyFourG(15) tenG(8) thirtyTwoG(12) twoG(3)
Represents the speed of a fibre channel port.
Following are the meanings of the enumerated values:
auto (1) - Negotiate to determine the speed
automatically.
oneG (2) - 1Gbit
twoG (3) - 2Gbit
fourG (4) - 4Gbit
autoMaxTwoG (5) - Negotiate to determine the
speed automatically upto a
maximum of 2Gbit.
eightG (6) - 8Gbit
autoMaxFourG (7) - Negotiate to determine the
speed automatically upto a
maximum of 4Gbit.
tenG (8) - 10GBit.
autoMaxEightG (9) - Negotiate to determine the
speed automatically upto a
maximum of 8Gbit.
sixteenG (10) - 16GBit.
autoMaxSixteenG (11) - Negotiate to determine the
speed automatically upto a
maximum of 16Gbit.
thirtyTwoG (12) - 32GBit.
autoMaxThirtyTwoG (13) - Negotiate to determine the
speed automatically upto a
maximum of 32Gbit.
fiftyG (14) - 50GBit.
sixtyFourG (15) - 64GBit.
autoMaxSixtyFourG (16) - Negotiate to determine the
speed automatically upto a
maximum of 64Gbit.FcNameId OCTET STRING (SIZE (8))Represents the World Wide Name (WWN) associated with
a Fibre Channel (FC) entity. A WWN is a 64 bit address
to uniquely identify each entity within a Fibre Channel
fabric.
FcNameIdOrZero OCTET STRING (SIZE (0 | 8 | 16))The World Wide Name (WWN) associated with a Fibre Channel
(FC) entity. WWNs were initially defined as 64-bits in
length. The latest definition (for future use) is 128-bits
long. The zero-length string value is used in circumstances
where the WWN is unassigned/unknown.
FcPortModuleTypes INTEGERembedded(4) gbic(3) gbicWithSerialID(6) gbicWithoutSerialID(7) glm(5) other(2) qsfp(19) sfpDwdm(18) sfpWithSerialID(8) sfpWithoutSerialID(9) unknown(1) x2Dwdm(20) x2Medium(12) x2Short(11) x2Tall(13) xenpak(17) xfp(10) xpakMedium(15) xpakShort(14) xpakTall(16)
Represents module type of the port connector. This
object refers to the hardware implementation of the port.
The enums are defined as per FC-GS-4 standard.
unknown (1) - unknown
other (2) - other
gbic (3) - gbic (gigabit interface card)
embedded (4) - gbic is part of the line card
and is unremovable
glm (5) - if its a gigabit link module
(GLM). A GLM has a different
form factor than GBIC. GLM is
not supported by our switch.
gbicWithSerialID (6) - If GBIC serial id can be read
gbicWithoutSerialID (7) - If GBIC serial id cannot be read
sfpWithSerialID (8) - If small form factor (SFP)
pluggable GBICs serial id can
be read
sfpWithoutSerialID (9) - If small form factor (SFP)
pluggable GBICs serial id
cannot be read
The following enums are module types for 10 gigabit small
form factor pluggable sfp port connectors.
xfp (10) - xfp
x2Short (11) - x2 short
x2Medium (12) - x2 medium
x2Tall (13) - x2 tall
xpakShort (14) - xpak short
xpakMedium (15) - xpak medium
xpakTall (16) - xpak tall
xenpak (17) - xenpak
sfpDwdm (18) - DWDM SFP type
qsfp (19) - Quad small form-factor (QSFP)
pluggable type
x2Dwdm (20) - x2 DWDM
.FcPortTxTypes INTEGERelectrical(5) longWaveLaser(2) longWaveLaserCostReduced(4) shortWaveLaser(3) tenGigBaseEr(8) tenGigBaseEw(12) tenGigBaseLr(7) tenGigBaseLw(11) tenGigBaseLx4(9) tenGigBaseSr(6) tenGigBaseSw(10) unknown(1)
Represents port transciever technology types.
unknown (1) - unknown
longWaveLaser (2) - 1550nm laser
shortWaveLaser (3) - 850nm laser
longWaveLaserCostReduced (4) - 1310nm laser
electrical (5) - electrical
tenGigBaseSr (6) - 10GBASE-SR 850nm laser
tenGigBaseLr (7) - 10GBASE-LR 1310nm laser
tenGigBaseEr (8) - 10GBASE-ER 1550nm laser
tenGigBaseLx4 (9) - 10GBASE-LX4 WWDM 1300nm laser
tenGigBaseSw (10) - 850nm laser
tenGigBaseLw (11) - 1310nm laser
tenGigBaseEw (12) - 1550nm laser
.
FcPortTypes INTEGERauto(1) bPort(5) ePort(4) fPort(2) flPort(3) fvPort(13) fxPort(6) nPort(9) nlPort(10) npPort(16) nxPort(11) portOperDown(14) sdPort(7) stPort(15) tePort(12) tfPort(17) tlPort(8) tnpPort(18)
Represents fibre channel port types:
auto (1) - Mode is determined by port initialization
scheme.
fPort (2) - Fibre channel fabric port.
flPort (3) - Fibre channel arbitrated loop port.
ePort (4) - Fabric Expansion port.
bPort (5) - Bridging port.
fxPort (6) - This port can only be f_port or fl_port.
sdPort (7) - SPAN destination port. SD_ports transmit
traffic copied from one or more source ports
for monitoring purposes.
tlPort (8) - Translation loop port.
nPort (9) - Fibre channel N port.
nlPort (10) - Fibre channel NL port.
nxPort (11) - This port can only be n_port or nl_port.
-- read only port types.
tePort (12) - Trunking e_port.
Note: A port which is administratively set
to 'ePort', will operationally have type
'tePort' if fcIfOperTrunkMode has the value
'trunk'.
fvPort (13) - Virtual Port.
portOperDown (14) - port operationally down
If a port is operationally down, the
port mode is unknown. In such cases
the operational port mode is shown
as 'portOperDown'.
stPort (15) - SPAN Tunnel destination port.
npPort (16) - N Proxy port mode applicable only to N-port
Virtualizer (NPV)
tfPort (17) - Trunking fibre channel fabric port.
tnpPort (18) - Trunking N Proxy port mode applicable only
to N-port Virtualizer (NPV).InterfaceOperMode INTEGERauto(1) bPort(5) ePort(4) evPort(18) fPort(2) flPort(3) fvPort(13) fxPort(6) ipsPort(17) mgmtPort(16) nPort(9) nlPort(10) npPort(19) nxPort(11) portOperDown(14) sdPort(7) stPort(15) tePort(12) tfPort(20) tlPort(8) tnpPort(21)
Represents the operational mode of an interface
auto (1) - Mode is determined by port initialization
scheme.
fPort (2) - Fibre channel fabric port.
flPort (3) - Fibre channel arbitrated loop port.
ePort (4) - Fabric Expansion port.
bPort (5) - Bridging port.
fxPort (6) - This port can only be f_port or fl_port.
sdPort (7) - SPAN destination port. SD_ports transmit
traffic copied from one or more source
ports for monitoring purposes.
tlPort (8) - Translation loop port.
nPort (9) - Fibre channel N port.
nlPort (10) - Fibre channel NL port.
nxPort (11) - This port can only be n_port or nl_port.
-- read only port types.
tePort (12) - Trunking e_port.
Note: A port which is administratively set
to 'ePort', will operationally have type
'tePort' if fcIfOperTrunkMode has the value
'trunk'.
fvPort (13) - Virtual Port.
portOperDown (14) - port operationally down
If a port is operationally down, the
port mode is unknown. In such cases
the operational port mode is shown
as 'portOperDown'.
stPort (15) - SPAN Tunnel destination port.
mgmtPort(16) - Mgmt Port.
ipsPort(17) - Ethernet Port.
evPort(18) - FCIP tunnels on Ethernet ports.
npPort (19) - N Proxy port mode applicable only
to N-port Virtualizer (NPV).
tfPort (20) - Trunking fibre channel fabric port.
tnpPort (21) - Trunking N Proxy port mode applicable only
to N-port Virtualizer (NPV).PortMemberList OCTET STRING (SIZE (0..64))A list of ifIndex's of the ports that are members of
this list.
The value of this object is a concatenation of zero or
more 4-octet strings, where each 4-octet string contains
a 32-bit ifIndex value in network byte order.
A zero length string value means this list has no
members.
VsanIndex Integer32 (1..4094)The VSAN id of a VSAN which uniquely identifies
a VSAN within a fabric. VSAN id is 12-bit
wide; so theoretically, 4096 VSANs can be defined in
a fabric and this device can be part of. However, VSAN
numbers 0 , 4094 and 4095 are reserved.