CISCO-ENTITY-FRU-CONTROL-MIB

ciscoSystems
The CISCO-ENTITY-FRU-CONTROL-MIB is used to monitor
and configure operational status of
Field Replaceable Units (FRUs) and other managable
physical entities of the system listed in the
Entity-MIB (RFC 2737) entPhysicalTable.

FRUs include assemblies such as power supplies, fans,
processor modules, interface modules, etc.
Organization
Cisco Systems, Inc.
Root OID
1.3.6.1.4.1.9.9.117
Last updated
Objects
160
Source
Show full MIB
snmptranslate -m CISCO-ENTITY-FRU-CONTROL-MIB -Tp
snmpwalk -v2c -c <community> -m CISCO-ENTITY-FRU-CONTROL-MIB <host> 1.3.6.1.4.1.9.9.117

Imports

CISCO-SMIciscoMgmt
ENTITY-MIBentPhysicalClass, entPhysicalContainedIn, entPhysicalIndex, entPhysicalModelName, entPhysicalName, entPhysicalVendorType
INET-ADDRESS-MIBInetAddress, InetAddressType
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION, TimeStamp, TruthValue

OID tree

NameOIDTypeAccessStatusExample
IciscoEntityFRUControlMIB1.3.6.1.4.1.9.9.117
NcefcMIBObjects1.3.6.1.4.1.9.9.117.1
NcefcFRUPower1.3.6.1.4.1.9.9.117.1.1
TcefcFRUPowerSupplyGroupTable1.3.6.1.4.1.9.9.117.1.1.1NA
RcefcFRUPowerSupplyGroupEntry1.3.6.1.4.1.9.9.117.1.1.1.1NA
CcefcPowerRedundancyMode1.3.6.1.4.1.9.9.117.1.1.1.1.1PowerRedundancyTypeRW
CcefcPowerUnits1.3.6.1.4.1.9.9.117.1.1.1.1.2DisplayStringRO
CcefcTotalAvailableCurrent1.3.6.1.4.1.9.9.117.1.1.1.1.3FRUCurrentTypeRO
CcefcTotalDrawnCurrent1.3.6.1.4.1.9.9.117.1.1.1.1.4FRUCurrentTypeRO
CcefcPowerRedundancyOperMode1.3.6.1.4.1.9.9.117.1.1.1.1.5PowerRedundancyTypeRO
CcefcPowerNonRedundantReason1.3.6.1.4.1.9.9.117.1.1.1.1.6INTEGERRO
CcefcTotalDrawnInlineCurrent1.3.6.1.4.1.9.9.117.1.1.1.1.7FRUCurrentTypeRO
TcefcFRUPowerStatusTable1.3.6.1.4.1.9.9.117.1.1.2NA
RcefcFRUPowerStatusEntry1.3.6.1.4.1.9.9.117.1.1.2.1NA
CcefcFRUPowerAdminStatus1.3.6.1.4.1.9.9.117.1.1.2.1.1PowerAdminTypeRW1
CcefcFRUPowerOperStatus1.3.6.1.4.1.9.9.117.1.1.2.1.2PowerOperTypeRO2
CcefcFRUCurrent1.3.6.1.4.1.9.9.117.1.1.2.1.3FRUCurrentTypeRO8933
CcefcFRUPowerCapability1.3.6.1.4.1.9.9.117.1.1.2.1.4BitsRO
CcefcFRURealTimeCurrent1.3.6.1.4.1.9.9.117.1.1.2.1.5FRUCurrentTypeRO
ScefcMaxDefaultInLinePower1.3.6.1.4.1.9.9.117.1.1.3Integer32 (0..12500)RWdeprecated
TcefcFRUPowerSupplyValueTable1.3.6.1.4.1.9.9.117.1.1.4NA
RcefcFRUPowerSupplyValueEntry1.3.6.1.4.1.9.9.117.1.1.4.1NA
CcefcFRUTotalSystemCurrent1.3.6.1.4.1.9.9.117.1.1.4.1.1FRUCurrentTypeRW
CcefcFRUDrawnSystemCurrent1.3.6.1.4.1.9.9.117.1.1.4.1.2FRUCurrentTypeRW
CcefcFRUTotalInlineCurrent1.3.6.1.4.1.9.9.117.1.1.4.1.3FRUCurrentTypeRW
CcefcFRUDrawnInlineCurrent1.3.6.1.4.1.9.9.117.1.1.4.1.4FRUCurrentTypeRW
CcefcFRUActualInputCurrent1.3.6.1.4.1.9.9.117.1.1.4.1.5FRUCurrentTypeRO
CcefcFRUActualOutputCurrent1.3.6.1.4.1.9.9.117.1.1.4.1.6FRUCurrentTypeRO
ScefcMaxDefaultHighInLinePower1.3.6.1.4.1.9.9.117.1.1.5Unsigned32RW
NcefcModule1.3.6.1.4.1.9.9.117.1.2
TcefcModuleTable1.3.6.1.4.1.9.9.117.1.2.1NA
RcefcModuleEntry1.3.6.1.4.1.9.9.117.1.2.1.1NA
CcefcModuleAdminStatus1.3.6.1.4.1.9.9.117.1.2.1.1.1ModuleAdminTypeRW
CcefcModuleOperStatus1.3.6.1.4.1.9.9.117.1.2.1.1.2ModuleOperTypeRO2
CcefcModuleResetReason1.3.6.1.4.1.9.9.117.1.2.1.1.3ModuleResetReasonTypeRO
CcefcModuleStatusLastChangeTime1.3.6.1.4.1.9.9.117.1.2.1.1.4TimeStampRO
CcefcModuleLastClearConfigTime1.3.6.1.4.1.9.9.117.1.2.1.1.5TimeStampRO
CcefcModuleResetReasonDescription1.3.6.1.4.1.9.9.117.1.2.1.1.6DisplayStringRO
CcefcModuleStateChangeReasonDescr1.3.6.1.4.1.9.9.117.1.2.1.1.7DisplayStringRO
CcefcModuleUpTime1.3.6.1.4.1.9.9.117.1.2.1.1.8FRUTimeSecondsRO
CcefcVmModuleOperStatus1.3.6.1.4.1.9.9.117.1.2.1.1.9CefcVmModuleOperTypeRO
CcefcVmModuleStatusLastChangeTime1.3.6.1.4.1.9.9.117.1.2.1.1.10TimeStampRO
TcefcIntelliModuleTable1.3.6.1.4.1.9.9.117.1.2.2NA
RcefcIntelliModuleEntry1.3.6.1.4.1.9.9.117.1.2.2.1NA
CcefcIntelliModuleIPAddrType1.3.6.1.4.1.9.9.117.1.2.2.1.1InetAddressTypeRO
CcefcIntelliModuleIPAddr1.3.6.1.4.1.9.9.117.1.2.2.1.2InetAddressRO
TcefcModuleLocalSwitchingTable1.3.6.1.4.1.9.9.117.1.2.3NA
RcefcModuleLocalSwitchingEntry1.3.6.1.4.1.9.9.117.1.2.3.1NA
CcefcModuleLocalSwitchingMode1.3.6.1.4.1.9.9.117.1.2.3.1.1INTEGERRW
NcefcMIBNotificationEnables1.3.6.1.4.1.9.9.117.1.3
ScefcMIBEnableStatusNotification1.3.6.1.4.1.9.9.117.1.3.1TruthValueRW2
ScefcEnablePSOutputChangeNotif1.3.6.1.4.1.9.9.117.1.3.2TruthValueRW2
NcefcFRUFan1.3.6.1.4.1.9.9.117.1.4
TcefcFanTrayStatusTable1.3.6.1.4.1.9.9.117.1.4.1NA
RcefcFanTrayStatusEntry1.3.6.1.4.1.9.9.117.1.4.1.1NA
CcefcFanTrayOperStatus1.3.6.1.4.1.9.9.117.1.4.1.1.1INTEGERROup(2)
CcefcFanTrayDirection1.3.6.1.4.1.9.9.117.1.4.1.1.2INTEGERRO
TcefcFanTable1.3.6.1.4.1.9.9.117.1.4.2NA
RcefcFanEntry1.3.6.1.4.1.9.9.117.1.4.2.1NA
CcefcFanSpeed1.3.6.1.4.1.9.9.117.1.4.2.1.1Unsigned32RO
CcefcFanSpeedPercent1.3.6.1.4.1.9.9.117.1.4.2.1.2CefcPercentOrMinusOneRO
NcefcPhysical1.3.6.1.4.1.9.9.117.1.5
TcefcPhysicalTable1.3.6.1.4.1.9.9.117.1.5.1NA
RcefcPhysicalEntry1.3.6.1.4.1.9.9.117.1.5.1.1NA
CcefcPhysicalStatus1.3.6.1.4.1.9.9.117.1.5.1.1.1INTEGERRO
NcefcPowerCapacity1.3.6.1.4.1.9.9.117.1.6
TcefcPowerSupplyInputTable1.3.6.1.4.1.9.9.117.1.6.1NA
RcefcPowerSupplyInputEntry1.3.6.1.4.1.9.9.117.1.6.1.1NA
CcefcPowerSupplyInputIndex1.3.6.1.4.1.9.9.117.1.6.1.1.1Unsigned32NA
CcefcPowerSupplyInputType1.3.6.1.4.1.9.9.117.1.6.1.1.2INTEGERRO
TcefcPowerSupplyOutputTable1.3.6.1.4.1.9.9.117.1.6.2NA
RcefcPowerSupplyOutputEntry1.3.6.1.4.1.9.9.117.1.6.2.1NA
CcefcPSOutputModeIndex1.3.6.1.4.1.9.9.117.1.6.2.1.1Unsigned32NA
CcefcPSOutputModeCurrent1.3.6.1.4.1.9.9.117.1.6.2.1.2FRUCurrentTypeRO
CcefcPSOutputModeInOperation1.3.6.1.4.1.9.9.117.1.6.2.1.3TruthValueRO
NcefcCooling1.3.6.1.4.1.9.9.117.1.7
TcefcChassisCoolingTable1.3.6.1.4.1.9.9.117.1.7.1NA
RcefcChassisCoolingEntry1.3.6.1.4.1.9.9.117.1.7.1.1NA
CcefcChassisPerSlotCoolingCap1.3.6.1.4.1.9.9.117.1.7.1.1.1Unsigned32RO
CcefcChassisPerSlotCoolingUnit1.3.6.1.4.1.9.9.117.1.7.1.1.2FRUCoolingUnitRO
TcefcFanCoolingTable1.3.6.1.4.1.9.9.117.1.7.2NA
RcefcFanCoolingEntry1.3.6.1.4.1.9.9.117.1.7.2.1NA
CcefcFanCoolingCapacity1.3.6.1.4.1.9.9.117.1.7.2.1.1Unsigned32RO
CcefcFanCoolingCapacityUnit1.3.6.1.4.1.9.9.117.1.7.2.1.2FRUCoolingUnitRO
TcefcModuleCoolingTable1.3.6.1.4.1.9.9.117.1.7.3NA
RcefcModuleCoolingEntry1.3.6.1.4.1.9.9.117.1.7.3.1NA
CcefcModuleCooling1.3.6.1.4.1.9.9.117.1.7.3.1.1Unsigned32RO
CcefcModuleCoolingUnit1.3.6.1.4.1.9.9.117.1.7.3.1.2FRUCoolingUnitRO
TcefcFanCoolingCapTable1.3.6.1.4.1.9.9.117.1.7.4NA
RcefcFanCoolingCapEntry1.3.6.1.4.1.9.9.117.1.7.4.1NA
CcefcFanCoolingCapIndex1.3.6.1.4.1.9.9.117.1.7.4.1.1Unsigned32 (1..4095)NA
CcefcFanCoolingCapModeDescr1.3.6.1.4.1.9.9.117.1.7.4.1.2SnmpAdminStringRO
CcefcFanCoolingCapCapacity1.3.6.1.4.1.9.9.117.1.7.4.1.3Unsigned32RO
CcefcFanCoolingCapCurrent1.3.6.1.4.1.9.9.117.1.7.4.1.4FRUCurrentTypeRO
CcefcFanCoolingCapCapacityUnit1.3.6.1.4.1.9.9.117.1.7.4.1.5FRUCoolingUnitRO
NcefcConnector1.3.6.1.4.1.9.9.117.1.8
TcefcConnectorRatingTable1.3.6.1.4.1.9.9.117.1.8.1NA
RcefcConnectorRatingEntry1.3.6.1.4.1.9.9.117.1.8.1.1NA
CcefcConnectorRating1.3.6.1.4.1.9.9.117.1.8.1.1.1FRUCurrentTypeRO
TcefcModulePowerConsumptionTable1.3.6.1.4.1.9.9.117.1.8.2NA
RcefcModulePowerConsumptionEntry1.3.6.1.4.1.9.9.117.1.8.2.1NA
CcefcModulePowerConsumption1.3.6.1.4.1.9.9.117.1.8.2.1.1FRUCurrentTypeRO
NcefcFRUMIBNotificationPrefix1.3.6.1.4.1.9.9.117.2
NcefcMIBNotifications1.3.6.1.4.1.9.9.117.2.0
!cefcModuleStatusChange1.3.6.1.4.1.9.9.117.2.0.1
!cefcPowerStatusChange1.3.6.1.4.1.9.9.117.2.0.2
!cefcFRUInserted1.3.6.1.4.1.9.9.117.2.0.3
!cefcFRURemoved1.3.6.1.4.1.9.9.117.2.0.4
!cefcUnrecognizedFRU1.3.6.1.4.1.9.9.117.2.0.5
!cefcFanTrayStatusChange1.3.6.1.4.1.9.9.117.2.0.6
!cefcPowerSupplyOutputChange1.3.6.1.4.1.9.9.117.2.0.7
!cefcVmModuleStatusChangeNotif1.3.6.1.4.1.9.9.117.2.0.8
NcefcMIBConformance1.3.6.1.4.1.9.9.117.3
NcefcMIBCompliances1.3.6.1.4.1.9.9.117.3.1
McefcMIBPowerCompliance1.3.6.1.4.1.9.9.117.3.1.1obsolete
McefcMIBPowerCompliance21.3.6.1.4.1.9.9.117.3.1.2deprecated
McefcMIBPowerCompliance31.3.6.1.4.1.9.9.117.3.1.3deprecated
McefcMIBPowerCompliance41.3.6.1.4.1.9.9.117.3.1.4deprecated
McefcMIBPowerCompliance51.3.6.1.4.1.9.9.117.3.1.5deprecated
McefcMIBPowerCompliance61.3.6.1.4.1.9.9.117.3.1.6
McefcMIBPowerCompliance71.3.6.1.4.1.9.9.117.3.1.7deprecated
McefcMIBPowerCompliance81.3.6.1.4.1.9.9.117.3.1.8deprecated
McefcMIBPowerCompliance91.3.6.1.4.1.9.9.117.3.1.9deprecated
McefcMIBPowerCompliance101.3.6.1.4.1.9.9.117.3.1.10
NcefcMIBGroups1.3.6.1.4.1.9.9.117.3.2
GcefcMIBPowerModeGroup1.3.6.1.4.1.9.9.117.3.2.1
GcefcMIBPowerFRUControlGroup1.3.6.1.4.1.9.9.117.3.2.2
GcefcMIBModuleGroup1.3.6.1.4.1.9.9.117.3.2.3
GcefcMIBInLinePowerControlGroup1.3.6.1.4.1.9.9.117.3.2.4deprecated
GcefcMIBNotificationEnablesGroup1.3.6.1.4.1.9.9.117.3.2.5
GcefcMgmtNotificationsGroup1.3.6.1.4.1.9.9.117.3.2.6
GcefcModuleGroupRev11.3.6.1.4.1.9.9.117.3.2.7
GcefcMIBPowerFRUValueGroup1.3.6.1.4.1.9.9.117.3.2.8
GcefcMIBFanTrayStatusGroup1.3.6.1.4.1.9.9.117.3.2.9
GcefcMIBPhysicalGroup1.3.6.1.4.1.9.9.117.3.2.10
GcefcMgmtNotificationsGroup21.3.6.1.4.1.9.9.117.3.2.11
GcefcMIBPowerOperModeGroup1.3.6.1.4.1.9.9.117.3.2.12
GcefcMIBInLinePowerControlGroupRev11.3.6.1.4.1.9.9.117.3.2.13
GcefcModuleExtGroup1.3.6.1.4.1.9.9.117.3.2.14
GcefcIntelliModuleGroup1.3.6.1.4.1.9.9.117.3.2.15
GcefcPowerCapacityGroup1.3.6.1.4.1.9.9.117.3.2.16
GcefcCoolingGroup1.3.6.1.4.1.9.9.117.3.2.17deprecated
GcefcConnectorRatingGroup1.3.6.1.4.1.9.9.117.3.2.18
GcefcMIBNotificationEnablesGroup21.3.6.1.4.1.9.9.117.3.2.19
GcefcMgmtNotificationsGroup31.3.6.1.4.1.9.9.117.3.2.20
GcefcMIBInLinePowerCurrentGroup1.3.6.1.4.1.9.9.117.3.2.21
GcefcMIBPowerRedundancyInfoGroup1.3.6.1.4.1.9.9.117.3.2.22
GcefcFanCoolingCapGroup1.3.6.1.4.1.9.9.117.3.2.23
GcefcMIBModuleLocalSwitchingGroup1.3.6.1.4.1.9.9.117.3.2.24
GcefcFRUPowerRealTimeStatusGroup1.3.6.1.4.1.9.9.117.3.2.25
GcefcFRUPowerCapabilityGroup1.3.6.1.4.1.9.9.117.3.2.26
GcefcFRUCoolingUnitGroup1.3.6.1.4.1.9.9.117.3.2.27
GcefcFRUFanCoolingUnitGroup1.3.6.1.4.1.9.9.117.3.2.28
GcefcCoolingGroup21.3.6.1.4.1.9.9.117.3.2.29
GcefcFanCoolingGroup1.3.6.1.4.1.9.9.117.3.2.30
GcefcFanDirectionGroup1.3.6.1.4.1.9.9.117.3.2.31
GcefcFanSpeedGroup1.3.6.1.4.1.9.9.117.3.2.32
GcefcPowerSupplyActualGroup1.3.6.1.4.1.9.9.117.3.2.33
GcefcVmModuleGroup1.3.6.1.4.1.9.9.117.3.2.34
GcefcVmModuleNotifsGroup1.3.6.1.4.1.9.9.117.3.2.35

Textual conventions

CefcPercentOrMinusOne Integer32 (-1 | 0..100)

Display hint: d

An integer that is in the range of a percent value.
A value of -1 means that the percentage is not available.
CefcVmModuleOperType INTEGER

down(1) goingDown(4) unknown(3) up(2)

Operational VM module states.  Valid values are :

down(1)        module is down.
up(2)          module is operational.
unknown(3)     module is unknown.
goingDown(4)   module is goingDown from Up.
FRUCoolingUnit INTEGER

cfm(1) watts(2)

The unit for the cooling capacity and requirement.

cfm(1)    Cubic feet per minute
watts(2)  Watts
FRUCurrentType Integer32 (-1000000000..1000000000)
a current measurement, on the system power supply
primary output, expressed in cefcPowerUnits.  Range is
from negative 1 million to positive one million
amperes.

A negative value expresses current used by the FRU.
A positive value expresses current supplied by the FRU.
FRUTimeSeconds Unsigned32
This is a non-negative integer which represents
the time in second between two epochs.

Since time is not discrete, it is rounded up to
the nearest second. For example, if the elapsed
time is greater than zero and less or equal to
one second, then one second is returned, etc.

When objects are defined which use this type, the
description of the object identifies both of the
reference epochs.
ModuleAdminType INTEGER

disabled(2) enabled(1) outOfServiceAdmin(4) reset(3)

Administratively desired module states.  Valid values are:

enabled(1)     module is operational.
disabled(2)    module is not operational.
reset(3)       module is reset. This value may be specified
               in a management protocol set operation, it will
               not be returned in response to a management
               protocol retrieval operation.
outOfServiceAdmin(4)   module is powered on but out of
                       service, set by CLI.
ModuleOperType INTEGER

boot(5) diagFailed(11) disabled(3) dormant(12) failed(7) fwDownloadFailure(27) fwDownloadSuccess(26) fwMismatchFound(25) mdr(24) mismatchConfig(10) mismatchWithParent(9) missing(8) ok(2) okButAuthFailed(23) okButDiagFailed(4) okButPowerOverCritical(20) okButPowerOverWarning(19) outOfServiceAdmin(13) outOfServiceEnvTemp(14) powerCycled(18) powerDenied(17) poweredDown(15) poweredUp(16) selfTest(6) syncInProgress(21) unknown(1) upgrading(22)

Operational module states.  Valid values are :

unknown(1)           Module is not in one of other states

 normal operational states:

ok(2)                 Module is operational.

disabled(3)           Module is administratively disabled.

okButDiagFailed(4)    Module is operational but there is some
                     diagnostic information available.

 transitional states:

boot(5)               Module is currently in the process of
                     bringing up image.  After boot, it starts
                     its operational software and transitions
                     to the appropriate state.

selfTest(6)           Module is performing selfTest.


 failure states:

failed(7)              Module has failed due to some condition
                      not stated above.

missing(8)             Module has been provisioned, but it is
                      missing

mismatchWithParent(9)  Module is not compatible with parent
                      entity. Module has not been provisioned
                      and wrong type of module is plugged in.
                      This state can be cleared by plugging
                      in the appropriate module.

mismatchConfig(10)     Module is not compatible with the
current
                      configuration. Module was correctly
                      provisioned earlier, however the module
                      was replaced by an incompatible module.
                      This state can be resolved by clearing
                      the configuration, or replacing with the
                      appropriate module.

diagFailed(11)         Module diagnostic test failed due to
some
                      hardware failure.

dormant(12)            Module is waiting for an external or
                      internal event to become operational.

outOfServiceAdmin(13)  module is administratively set to be
                      powered on but out of service.

outOfServiceEnvTemp(14)Module is powered on but out of service,
                      due to environmental temperature problem.
                      An out-o-service module consumes less
                      power thus will cool down the board.

poweredDown(15)       Module is in powered down state.

poweredUp(16)         Module is in powered up state.

powerDenied(17)       System does not have enough power in
                      power budget to power on this module.

powerCycled(18)       Module is being power cycled.

okButPowerOverWarning(19) Module is drawing more power than
                      allocated to this module. The module
                      is still operational but may go into
                      a failure state. This state may be
                      caused by misconfiguration of power
                      requirements (especially for inline
                      power).

okButPowerOverCritical(20) Module is drawing more power
                      than this module is designed to
                      handle. The module is still
                      operational but may go into a
                      failure state and could potentially
                      take the system down. This state
                      may be caused by gross misconfi-
                      guration of power requirements
                      (especially for inline power).

syncInProgress(21)    Synchronization in progress.
                      In a high availability system there
                      will be 2 control modules, active and
                      standby.
                      This transitional state specifies the
                      synchronization of data between the
                      active and standby modules.

upgrading(22)         Module is upgrading.

okButAuthFailed(23)   Module is operational but did not pass
                      hardware integrity verification.

mdr(24)               Module is undergoing a Minimum
                      Disruptive Restart (MDR) upgrade.

 firmware download states:

fwMismatchFound(25)   Mistmatch found between current firmware
                      version and the firmware version in the
                      system image.

fwDownloadSuccess(26) Module firmware download succeeded.

fwDownloadFailure(27) Module firmware download failed.
ModuleResetReasonType INTEGER

abortRevReset(19) burnBootReset(20) cacheErrorReset(15) clearConfigReset(4) controllerReset(10) deviceDriverReset(16) downgradeReset(14) lowVoltageReset(9) manualReset(5) memoryProtectionErrorReset(23) missingTaskReset(8) nonNativeConfigClearReset(22) parityError(3) powerUp(2) resourceOverflowReset(7) restoreConfigReset(18) softwareExceptionReset(17) standbyCdHealthierReset(21) switchoverReset(12) systemReset(11) unknown(1) upgradeReset(13) watchDogTimeoutReset(6)

Describes the reason for the last module reset operation.

unknown(1)                      source of the reset is not
                                identified

powerUp(2)                      system power up operation

parityError(3)                  parity error during system
                                bring up operation

clearConfigReset(4)             reset due to clear
                                configuration operation

manualReset(5)                  reset due to administrative
                                request

watchDogTimeoutReset(6)         reset due to watchdog timeout

resourceOverflowReset(7)        reset due to resource overflow

missingTaskReset(8)             reset due to missing task

lowVoltageReset(9)              reset due to low voltage

controllerReset(10)             reset by controller

systemReset(11)                 system reset

switchoverReset(12)             reset due to user initiated
                                graceful switchover

upgradeReset(13)                reset due to upgrade

downgradeReset(14)              reset due to downgrade

cacheErrorReset(15)             reset due to cache error

deviceDriverReset(16)           reset due to device driver
                                error

softwareExceptionReset(17)      reset due to software
                                exception

restoreConfigReset(18)          reset due to configuration
                                restoration

abortRevReset(19)               reset due to revision change
                                abort

burnBootReset(20)               reset due to boot image
                                change

standbyCdHealthierReset(21)     reset to switch to healthier
                                standby card

nonNativeConfigClearReset(22)   reset due clearing of
                                non-native configuration

memoryProtectionErrorReset(23)  reset due to memory protection
                                violation.
PowerAdminType INTEGER

inlineAuto(3) inlineOn(4) off(2) on(1) powerCycle(5)

Administratively desired FRU power state types.  valid values
are:
on(1):  Turn FRU on.
off(2): Turn FRU off.

The inline power means that the FRU itself won't cost any power,
but the external device connecting to the FRU will drain the
power from FRU.  For example, the IP phone device.  The FRU is a
port of a switch with voice ability and IP phone will cost power
from the port once it connects to the port.

inlineAuto(3): Turn FRU inline power to auto mode. It means that
the FRU will try to detect whether the connecting device needs
power or not.  If it needs power, the FRU will supply power.  If
it doesn't, the FRU will treat the device as a regular network
device.

inlineOn(4): Turn FRU inline power to on mode.  It means that
once the device connects to the FRU, the FRU will always supply
power to the device no matter the device needs the power or not.

powerCycle(5): Power cycle the FRU.  This value may be specified
in a management protocol set operation, it will not be returned
in response to a management protocol retrieval operation.
PowerOperType INTEGER

failed(8) offAdmin(3) offConnectorRating(11) offCooling(10) offDenied(4) offEnvFan(7) offEnvOther(1) offEnvPower(5) offEnvTemp(6) on(2) onButFanFail(9) onButInlinePowerFail(12)

Operational FRU Status types.  valid values are:

offEnvOther(1)   FRU is powered off because of a problem not
                 listed below.

on(2):           FRU is powered on.

offAdmin(3):     Administratively off.

offDenied(4):    FRU is powered off because available
                 system power is insufficient.

offEnvPower(5):  FRU is powered off because of power problem in
                 the FRU.  for example, the FRU's power
                 translation (DC-DC converter) or distribution
                 failed.

offEnvTemp(6):   FRU is powered off because of temperature
                 problem.

offEnvFan(7):    FRU is powered off because of fan problems.

failed(8):       FRU is in failed state.

onButFanFail(9): FRU is on, but fan has failed.

offCooling(10):  FRU is powered off because of the system's
                 insufficient cooling capacity.

offConnectorRating(11): FRU is powered off because of the
                        system's connector rating exceeded.

onButInlinePowerFail(12): The FRU on, but no inline power
                          is being delivered as the
                          data/inline power component of the
                          FRU has failed.
PowerRedundancyType INTEGER

combined(3) inPwrSrcRedundant(6) nonRedundant(4) notsupported(1) psRedundant(5) psRedundantSingleInput(7) redundant(2)

power supply redundancy modes.  valid values are:

notsupported(1): Read-only operational state, indicates
    that the requested administrative state (redundant(2),
    combined(3), psRedundant(5), inPwrSrcRedundant(6)
    or psRedundantSingleInput(7)) is not supported
    by the system.

redundant(2): A single power supply output can power
    the entire system, although there are more than
    one matched supply in the system.

    In the systems which support multiple level of
    redundancy, such as input power redundancy, this
    state indicates that redundancy is enabled on
    all levels.

combined(3): The combined output of the power supplies
    are available to operate the system when there are
    more than one matched power supply in the system.

    In the platforms which support multiple level of
    redundancy, such as input redundancy, this state
    indicates that no redundancy on all levels.

nonRedundant(4): Read-only operational state, indicates
    that there is only one power supply or there are
    unmatched power supplies in the system.

psRedundant(5): Only the power output redundancy
    is enabled in the systems which support multiple
    levels of redundancy.  All other types of redundancy,
    such as input power redundancy, are disabled.

    This value is only supported by the systems which
    support multiple levels of redundancy.

inPwrSrcRedundant(6): Only the input power redundancy
    is enabled in the systems which support multiple
    levels of redundancy.  All other types of redundancy,
    such as output power redundancy, are disabled.

    This value is only supported by the systems which
    support input power redundancy.

 psRedundantSingleInput(7): Only the power redundancy with
    single input is enabled in the systems which support
    multiple levels of redundancy.  All other types of
    redundancy, such as output power redundancy, are disabled.

    This value is only supported by the systems which
    support power redundancy with single input.

Traps / Notifications

Groups and compliance