MIB Browser

CERENT-OPTICAL-MONITOR-MIB

Cerent Corporation
This MIB module defines objects to monitor optical
characteristics and set corresponding thresholds, on the
optical interfaces in a network element.
This module is an adaptation of CISCO-OPTICAL-MONITOR-MIB.
Organization
Cisco Systems, Inc.
Root OID
1.3.6.1.4.1.3607.1.10.70
Last updated
Objects
43
Source
Show full MIB
snmptranslate -m CERENT-OPTICAL-MONITOR-MIB -Tp
snmpwalk -v2c -c <community> -m CERENT-OPTICAL-MONITOR-MIB <host> 1.3.6.1.4.1.3607.1.10.70

Imports

CERENT-GLOBAL-REGISTRYcerentGeneric, cerentModules, cerentRequirements
CERENT-TCCerentPeriod
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue

OID tree

NameOIDTypeAccessStatus
IcerentOpticalMonitorMIB1.3.6.1.4.1.3607.1.10.70
NcerentOpticalMonitorMIBObjects1.3.6.1.4.1.3607.2.30
NcerentOpticalMonGroup1.3.6.1.4.1.3607.2.30.1
TcOpticalMonTable1.3.6.1.4.1.3607.2.30.1.1NA
RcOpticalMonEntry1.3.6.1.4.1.3607.2.30.1.1.1NA
CcOpticalMonDirection1.3.6.1.4.1.3607.2.30.1.1.1.1OpticalIfDirectionNA
CcOpticalMonParameterType1.3.6.1.4.1.3607.2.30.1.1.1.2OpticalParameterTypeNA
CcOpticalParameterValue1.3.6.1.4.1.3607.2.30.1.1.1.3OpticalParameterValueRO
CcOpticalParamHighAlarmThresh1.3.6.1.4.1.3607.2.30.1.1.1.4OpticalParameterValueRW
CcOpticalParamHighWarning15MinThresh1.3.6.1.4.1.3607.2.30.1.1.1.5OpticalParameterValueRW
CcOpticalParamHighWarning1DayThresh1.3.6.1.4.1.3607.2.30.1.1.1.6OpticalParameterValueRW
CcOpticalParamLowAlarmThresh1.3.6.1.4.1.3607.2.30.1.1.1.7OpticalParameterValueRW
CcOpticalParamLowWarning15MinThresh1.3.6.1.4.1.3607.2.30.1.1.1.8OpticalParameterValueRW
CcOpticalParamLowWarning1DayThresh1.3.6.1.4.1.3607.2.30.1.1.1.9OpticalParameterValueRW
CcOpticalParamLowDegradeThresh1.3.6.1.4.1.3607.2.30.1.1.1.10OpticalParameterValueRW
CcOpticalParamHighDegradeThresh1.3.6.1.4.1.3607.2.30.1.1.1.11OpticalParameterValueRW
NcerentOpticalPMGroup1.3.6.1.4.1.3607.2.30.2
TcOpticalPMCurrentTable1.3.6.1.4.1.3607.2.30.2.1NA
RcOpticalPMCurrentEntry1.3.6.1.4.1.3607.2.30.2.1.1NA
CcOpticalPMCurrentDirection1.3.6.1.4.1.3607.2.30.2.1.1.1OpticalIfDirectionNA
CcOpticalPMCurrentParamType1.3.6.1.4.1.3607.2.30.2.1.1.2OpticalParameterTypeNA
CcOpticalPMCurrentPeriod1.3.6.1.4.1.3607.2.30.2.1.1.3CerentPeriodNA
CcOpticalPMCurrentMaxParam1.3.6.1.4.1.3607.2.30.2.1.1.4OpticalParameterValueRO
CcOpticalPMCurrentMinParam1.3.6.1.4.1.3607.2.30.2.1.1.5OpticalParameterValueRO
CcOpticalPMCurrentMeanParam1.3.6.1.4.1.3607.2.30.2.1.1.6OpticalParameterValueRO
TcOpticalPMIntervalTable1.3.6.1.4.1.3607.2.30.2.2NA
RcOpticalPMIntervalEntry1.3.6.1.4.1.3607.2.30.2.2.1NA
CcOpticalPMIntervalDirection1.3.6.1.4.1.3607.2.30.2.2.1.1OpticalIfDirectionNA
CcOpticalPMIntervalParamType1.3.6.1.4.1.3607.2.30.2.2.1.2OpticalParameterTypeNA
CcOpticalPMIntervalPeriod1.3.6.1.4.1.3607.2.30.2.2.1.3CerentPeriodNA
CcOpticalPMIntervalNumber1.3.6.1.4.1.3607.2.30.2.2.1.4Integer32 (1..96)NA
CcOpticalPMIntervalMaxParam1.3.6.1.4.1.3607.2.30.2.2.1.5OpticalParameterValueRO
CcOpticalPMIntervalMinParam1.3.6.1.4.1.3607.2.30.2.2.1.6OpticalParameterValueRO
CcOpticalPMIntervalMeanParam1.3.6.1.4.1.3607.2.30.2.2.1.7OpticalParameterValueRO
CcOpticalPMIntervalValidData1.3.6.1.4.1.3607.2.30.2.2.1.8TruthValueRO
NcerentOpticalMonitorMIBConformance1.3.6.1.4.1.3607.5.20
NcerentOpticalMonitorMIBCompliances1.3.6.1.4.1.3607.5.20.1
McerentOpticalMonitorMIBCompliance1.3.6.1.4.1.3607.5.20.1.1
NcerentOpticalMonitorMIBGroups1.3.6.1.4.1.3607.5.20.2
GcerentOpticalMIBMonGroup1.3.6.1.4.1.3607.5.20.2.1
GcerentOpticalMIBThresholdGroup1.3.6.1.4.1.3607.5.20.2.2
GcerentOpticalMIBPMGroup1.3.6.1.4.1.3607.5.20.2.3
GcerentOpticalDwdmNetworkMIBThresholdGroup1.3.6.1.4.1.3607.5.20.2.4

Textual conventions

OpticalIfDirection INTEGER

notApplicable(3) receive(1) transmit(2)

This value indicates the direction being monitored at
the optical interface.
OpticalParameterType INTEGER

acPower(2) addPower(11) apdTemp(3) biasCurrent(5) gain(9) laserTemp(4) oscPower(10) peltierCurrent(6) power(1) voa(8) xcvrVoltage(7)

This value indicates the optical parameter that is
       being monitored. Valid values are -

       power (1)          : Optical Power (AC + DC).
       acPower (2)        : Optical AC Power.
       apdTemp (3)        : Avalanche Photo Detector Temperature.
       laserTemp (4)      : Laser Temperature.
       biasCurrent (5)    : Laser bias current.
       peltierCurrent (6) : Laser peltier current.
       xcvrVoltage (7)    : Transceiver voltage.
       voa (8)	           : Variable Optical Attenuation Failure & Degrade Th.
       gain (9)           : Optical amplifier gain Failure & Degrade Th.
oscPower (10)	   : OSC Optical Power
addPower (11)	   : Add Optical Power
OpticalParameterValue Integer32 (-1000000..1000000)
The value of the optical parameter that is being monitored.

The range of values varies depending on the type of optical
parameter being monitored, as identified by a corresponding
object with syntax OpticalParameterType.

when the optical parameter being monitored is 'power' or
'acpower', the supported range is from -1000 to 1000, in
1/10ths of dBm.
Example: Actual power of -40 dbm is represented as -400.
Actual power level of +30 dBm is represented as 300.

When the optical parameter being monitored is 'laserTemp' or
'apdTemp', the supported range is from -10000 to 30000, in
1/100ths of degrees centigrade.
Example: A value of 2355 represents a temperature reading of
23.55 degrees C.

When the optical parameter being monitored is 'biasCurrent',
the supported range is from 0 to 1000, in 1/10ths of
percentage (%).
Example: A value of 500 represents a bias current threshold
of 50.0 %.

When the optical parameter being monitored is 'peltierCurrent',
the supported range is from 0 to 10000, in milliamperes.

When the optical parameter being monitored is 'xcvrVoltage',
the supported range is from 0 to 100000, in 1/10ths of
millivolts.
Example: A Value of 115 represents a transceiver voltage
reading of 11.5 millivolts.

The distinguished value of '-1000000' indicates that the object
has not yet been initialized or does not apply.