ASYNCOS-MAIL-MIB
IronPort Systems, Inc.MIB for Cisco IronPort Mail Gateway/Email Security Appliances
snmptranslate -m ASYNCOS-MAIL-MIB -Tpsnmpwalk -v2c -c <community> -m ASYNCOS-MAIL-MIB <host> 1.3.6.1.4.1.15497.1.1.1Imports
| IRONPORT-SMI | asyncOSMail |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IasyncOSMailObjects | 1.3.6.1.4.1.15497.1.1.1 | |||
identity MIB for Cisco IronPort Mail Gateway/Email Security Appliances | ||||
| SperCentMemoryUtilization | 1.3.6.1.4.1.15497.1.1.1.1 | Integer32 (0..100) | RO | |
scalar · Integer32 (0..100) · read-only · current This object provides a general idea of how much memory is being consumed by the appliance software. | ||||
| SperCentCPUUtilization | 1.3.6.1.4.1.15497.1.1.1.2 | Integer32 (0..100) | RO | |
scalar · Integer32 (0..100) · read-only · current This object provides a general idea of how busy the CPU is according to the appliance software, within the last 5 seconds of utilization. This measurement may or may not reflect the overall CPU utilization of the appliance, and may or may not be a per-process or a per-thread CPU utilization value. | ||||
| SperCentDiskIOUtilization | 1.3.6.1.4.1.15497.1.1.1.3 | Integer32 (0..100) | RO | |
scalar · Integer32 (0..100) · read-only · current This object provides a general idea of how much disk I/O has been generated within the last 5-15 seconds. | ||||
| SperCentQueueUtilization | 1.3.6.1.4.1.15497.1.1.1.4 | Integer32 (0..100) | RO | |
scalar · Integer32 (0..100) · read-only · current Percent of total queue capacity used. | ||||
| SqueueAvailabilityStatus | 1.3.6.1.4.1.15497.1.1.1.5 | INTEGER | RO | |
scalar · INTEGER · read-only · current Queue space status: enough space, queue near full or queue full.
| ||||
| SresourceConservationReason | 1.3.6.1.4.1.15497.1.1.1.6 | INTEGER | RO | |
scalar · INTEGER · read-only · current Reason system is in Resource Conservation Mode.
| ||||
| SmemoryAvailabilityStatus | 1.3.6.1.4.1.15497.1.1.1.7 | INTEGER | RO | |
scalar · INTEGER · read-only · current Mail Transfer process's memory availability status.
| ||||
| TpowerSupplyTable | 1.3.6.1.4.1.15497.1.1.1.8 | NA | ||
table · not-accessible · current A table of one or power supply entries. | ||||
| RpowerSupplyEntry | 1.3.6.1.4.1.15497.1.1.1.8.1 | NA | ||
row · not-accessible · current Entry containing the status of a power supply and the corresponding power supply configuration redundancy state.
| ||||
| CpowerSupplyIndex | 1.3.6.1.4.1.15497.1.1.1.8.1.1 | Integer32 (1..8) | RO | |
column · Integer32 (1..8) · read-only · current Unique index for a power supply source. This index is for SNMP purposes only; it has no intrinsic value. | ||||
| CpowerSupplyStatus | 1.3.6.1.4.1.15497.1.1.1.8.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current Represents the status of a power supply.
powerSupplyNotInstalled -
The power supply is not detected by the chassis as
being physically present.
powerSupplyHealthy -
The power supply is physically present and is
actively servicing the appliance with power.
powerSupplyNoAC -
The power supply is physically present but is not
actively servicing the appliance with power.
powerSupplyFaulty -
The power supply is failed per the vendor defined
operating specifications for the power supply.
| ||||
| CpowerSupplyRedundancy | 1.3.6.1.4.1.15497.1.1.1.8.1.3 | INTEGER | RO | |
column · INTEGER · read-only · current Represents the status of a collection of one or more power
supplies.
powerSupplyRedundancyOK -
All power supplies are in a powerSupplyHealthy state.
powerSupplyRedundancyLost -
One or more power supplies are in a
powerSupplyNotInstalled, powerSupplyNoAC, or
powerSupplyFaulty state.
| ||||
| CpowerSupplyName | 1.3.6.1.4.1.15497.1.1.1.8.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current A textual name for a power supply. | ||||
| TtemperatureTable | 1.3.6.1.4.1.15497.1.1.1.9 | NA | ||
table · not-accessible · current A table of chassis temperature sensor states. | ||||
| RtemperatureEntry | 1.3.6.1.4.1.15497.1.1.1.9.1 | NA | ||
row · not-accessible · current An entry in the temperature sensor table representing the status of the corresponding sensor in or on the appliance.
| ||||
| CtemperatureIndex | 1.3.6.1.4.1.15497.1.1.1.9.1.1 | Integer32 (1..64) | NA | |
column · Integer32 (1..64) · not-accessible · current Unique index for the temperature sensor being instrumented. This index is for SNMP purposes only; it has no intrinsic value. | ||||
| CdegreesCelsius | 1.3.6.1.4.1.15497.1.1.1.9.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current Temperature reading for the sensor being instrumented in Centrigrade units. This is correct according to the relative accuracy of the sensor being instrumented. | ||||
| CtemperatureName | 1.3.6.1.4.1.15497.1.1.1.9.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current Textual description for sensor being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. | ||||
| TfanTable | 1.3.6.1.4.1.15497.1.1.1.10 | NA | ||
table · not-accessible · current A table of chassis fan entries. | ||||
| RfanEntry | 1.3.6.1.4.1.15497.1.1.1.10.1 | NA | ||
row · not-accessible · current An entry in the chassis fan table with the speed of a fan in the chassis, as well as the name of the corresponding fan.
| ||||
| CfanIndex | 1.3.6.1.4.1.15497.1.1.1.10.1.1 | Integer32 (1..64) | NA | |
column · Integer32 (1..64) · not-accessible · current Unique index of the chassis fan being instrumented. This index is for SNMP purposes only; it has no intrinsic value. | ||||
| CfanRPMs | 1.3.6.1.4.1.15497.1.1.1.10.1.2 | Gauge32 | RO | |
column · Gauge32 · read-only · current Speed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow requirements for the appliance it's instrumented in, but in general when fanRPMs reports 0 RPMs the respective fan has failed. | ||||
| CfanName | 1.3.6.1.4.1.15497.1.1.1.10.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current A textual name of the chassis fan being instrumented. | ||||
| SworkQueueMessages | 1.3.6.1.4.1.15497.1.1.1.11 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Number of messages in the work queue. | ||||
| TkeyExpirationTable | 1.3.6.1.4.1.15497.1.1.1.12 | NA | ||
table · not-accessible · current A table of Feature Key expiration entries. | ||||
| RkeyExpirationEntry | 1.3.6.1.4.1.15497.1.1.1.12.1 | NA | ||
row · not-accessible · current Entry containing a Feature Key, its expiration status, and whether or not the Feature Key is perpetual.
| ||||
| CkeyExpirationIndex | 1.3.6.1.4.1.15497.1.1.1.12.1.1 | Integer32 (1..1024) | RO | |
column · Integer32 (1..1024) · read-only · current Unique index for a Feature Key applicable to the appliance. This index is for SNMP purposes only; it has no intrinsic value. | ||||
| CkeyDescription | 1.3.6.1.4.1.15497.1.1.1.12.1.2 | DisplayString | RO | |
column · DisplayString · read-only · current Textual description for a Feature Key applicable to the appliance. | ||||
| CkeyIsPerpetual | 1.3.6.1.4.1.15497.1.1.1.12.1.3 | TruthValue | RO | |
column · TruthValue · read-only · current Boolean value represented by True if Feature Key is perpetual, or False if the Feature Key is normal or expired. | ||||
| CkeySecondsUntilExpire | 1.3.6.1.4.1.15497.1.1.1.12.1.4 | Gauge32 | RO | |
column · Gauge32 · read-only · current Seconds until the valid Feature Key expires. Only applies to non-perpetual Feature Keys, and is 0 when the Feature Key has expired. | ||||
| TupdateTable | 1.3.6.1.4.1.15497.1.1.1.13 | NA | ||
table · not-accessible · current A table of one or more update entries. | ||||
| RupdateEntry | 1.3.6.1.4.1.15497.1.1.1.13.1 | NA | ||
row · not-accessible · current Entry containing a name and number of successful and failed updates for a service, including but not limited to: spam or virus definitions and timezone updates.
| ||||
| CupdateIndex | 1.3.6.1.4.1.15497.1.1.1.13.1.1 | Integer32 (1..1024) | RO | |
column · Integer32 (1..1024) · read-only · current Unique index for an update service. This index is for SNMP purposes only; it has no intrinsic value. | ||||
| CupdateServiceName | 1.3.6.1.4.1.15497.1.1.1.13.1.2 | DisplayString | RO | |
column · DisplayString · read-only · current A textual name for an update entry. | ||||
| Cupdates | 1.3.6.1.4.1.15497.1.1.1.13.1.3 | Counter32 | RO | |
column · Counter32 · read-only · current The number of successful attempts that have occurred when updating a service. | ||||
| CupdateFailures | 1.3.6.1.4.1.15497.1.1.1.13.1.4 | Counter32 | RO | |
column · Counter32 · read-only · current The number of failed attempts that have occurred when updating a service. | ||||
| SoldestMessageAge | 1.3.6.1.4.1.15497.1.1.1.14 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current The number of seconds the oldest message has been in queue | ||||
| SoutstandingDNSRequests | 1.3.6.1.4.1.15497.1.1.1.15 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Number of DNS requests that have been sent but for which no reply has been received. | ||||
| SpendingDNSRequests | 1.3.6.1.4.1.15497.1.1.1.16 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Number of DNS requests waiting to be sent. | ||||
| SraidEvents | 1.3.6.1.4.1.15497.1.1.1.17 | Counter32 | RO | |
scalar · Counter32 · read-only · current The total number of RAID events that have occurred since the last appliance power on event. | ||||
| TraidTable | 1.3.6.1.4.1.15497.1.1.1.18 | NA | ||
table · not-accessible · current Unique index for a drive being instrumented in the appliance. This index is for SNMP purposes only; it has no intrinsic value. | ||||
| RraidEntry | 1.3.6.1.4.1.15497.1.1.1.18.1 | NA | ||
row · not-accessible · current An entry in the RAID table representing the status of a drive attached to a RAID controller in the appliance.
| ||||
| CraidIndex | 1.3.6.1.4.1.15497.1.1.1.18.1.1 | Integer32 (1..1024) | RO | |
column · Integer32 (1..1024) · read-only · current Unique index for a drive attached to a RAID controller in the appliance. This index is for SNMP purposes only; it has no intrinsic value. | ||||
| CraidStatus | 1.3.6.1.4.1.15497.1.1.1.18.1.2 | INTEGER | RO | |
column · INTEGER · read-only · current Represents the status of a a drive attached to a RAID
controller in the appliance.
driveHealthy -
The corresponding drive is connected to the RAID
controller and functioning as a healthy member in
the RAID volume.
driveFailure -
The drive is either disconnected from the RAID
controller, or has failed to operate within
thresholds defined in vendor specifications for the
drive and the controller.
driveRebuild -
The corresponding drive is connected to the RAID
controller. It is being rebuilt according to the
RAID controller specific rebuild algorithm for the
current operating mode of the RAID volume.
| ||||
| CraidID | 1.3.6.1.4.1.15497.1.1.1.18.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current A textual name for a drive attached to a RAID controller in the appliance. | ||||
| CraidLastError | 1.3.6.1.4.1.15497.1.1.1.18.1.4 | DisplayString | RO | |
column · DisplayString · read-only · current The textual description of the last error message reported by the RAID controller or corresponding driver if one has occurred. This is 'No Error' if the corresponding drive's state is driveHealthy, or a controller or driver defined specific textual description if the drive's state is not driveHealthy. | ||||
| SopenFilesOrSockets | 1.3.6.1.4.1.15497.1.1.1.19 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current This object notes how many files or sockets are open on the appliance. In normal operating conditions, the measurement is taken at least once every 5-15 seconds. | ||||
| SmailTransferThreads | 1.3.6.1.4.1.15497.1.1.1.20 | Gauge32 | RO | |
scalar · Gauge32 · read-only · current Number of threads that perform some task related to transferring mail. | ||||
| SconnectionURL | 1.3.6.1.4.1.15497.1.1.1.21 | DisplayString | AN | |
scalar · DisplayString · accessible-for-notify · current The URL which will be used to test HTTP URL connectivity. | ||||
| ShsmErrorReason | 1.3.6.1.4.1.15497.1.1.1.22 | DisplayString | RO | |
scalar · DisplayString · read-only · current A textual reason describing the last HSM authentication error. | ||||
| NasyncOSMailNotifications | 1.3.6.1.4.1.15497.1.1.2 | |||
| !resourceConservationMode | 1.3.6.1.4.1.15497.1.1.2.1 | |||
notification · current Memory or queue utilization caused system to enter resource conservation mode.
| ||||
| !powerSupplyStatusChange | 1.3.6.1.4.1.15497.1.1.2.2 | |||
notification · current A powerSupplyStatusChange notification is sent when power supply with powerSupplyName changes states, as per one of the states available in powerSupplyStatus. This notification contains the opaque type for powerSupplyName of the power supply which has changed state.
| ||||
| !highTemperature | 1.3.6.1.4.1.15497.1.1.2.3 | |||
notification · current A highTemperature notification is sent when the temperature of an instrumented sensor in the chassis has exceeded vendor defined specifications. This notification contains the opaque type for the temperatureName of the sensor which has failed.
| ||||
| !fanFailure | 1.3.6.1.4.1.15497.1.1.2.4 | |||
notification · current A fanFailure notification is sent when the speed of the fan is not operating per the vendor defined specifications, as discussed in fanRPMs. This notification contains the opaque type for the fanName of the fan which has failed.
| ||||
| !keyExpiration | 1.3.6.1.4.1.15497.1.1.2.5 | |||
notification · current A keyExpiration notification is sent when the corresponding Feature Key is pending expiration or has expired. This notification contains the opaque type for the keyDescription of the Feature Key that is pending expiration or has expired.
| ||||
| !updateFailure | 1.3.6.1.4.1.15497.1.1.2.6 | |||
notification · current An updateFailure notification is sent when a service fails to update properly. This notification contains the opaque type for the updateServiceName of the update service that has failed.
| ||||
| !raidStatusChange | 1.3.6.1.4.1.15497.1.1.2.7 | |||
notification · current A raidStatusChange notification is sent when drive with raidID changes states, as per one of the states available in raidStatus. This notification contains the opaque type for raidID of the drive which has changed state.
| ||||
| !connectivityFailure | 1.3.6.1.4.1.15497.1.1.2.8 | |||
notification · current A connectivityFailure notification is sent when the URL denoted by configured connectionURL is unreachable, or the request returned an HTTP code was not between 200, inclusive, and 300, exclusive. The connectionURL configured is returned when the notification is triggered.
| ||||
| !memoryUtilizationExceeded | 1.3.6.1.4.1.15497.1.1.2.9 | |||
notification · current A memoryUtilizationExceeded notification is sent when the value in perCentMemoryUtilization has exceeded the configured memory usage threshold. The percentage that exceeded the threshold in perCentMemoryUtilization is returned via the notification.
| ||||
| !cpuUtilizationExceeded | 1.3.6.1.4.1.15497.1.1.2.10 | |||
notification · current A cpuUtilizationExceeded notification is sent when the value in perCentCPUUtilization has exceeded the configured CPU usage threshold. The percentage that exceeded the threshold in perCentCPUUtilization is returned via the notification.
| ||||
| !hsmInitializationFailure | 1.3.6.1.4.1.15497.1.1.2.11 | |||
notification · current A hsmInitializationFailure notification is sent when the Hardware Security Module card cannot be initialized. The initialization error in hsmErrorReason is returned via the notification.
| ||||
| !hsmResetLoginFailure | 1.3.6.1.4.1.15497.1.1.2.12 | |||
notification · current A hsmResetLoginFailure notification is sent when the Hardware Security Module card is reset due to multiple Crypto Officer login failures. The reset login error in hsmErrorReason is returned via the notification.
| ||||
Traps / Notifications
- connectivityFailure
1.3.6.1.4.1.15497.1.1.2.8 - cpuUtilizationExceeded
1.3.6.1.4.1.15497.1.1.2.10 - fanFailure
1.3.6.1.4.1.15497.1.1.2.4 - highTemperature
1.3.6.1.4.1.15497.1.1.2.3 - hsmInitializationFailure
1.3.6.1.4.1.15497.1.1.2.11 - hsmResetLoginFailure
1.3.6.1.4.1.15497.1.1.2.12 - keyExpiration
1.3.6.1.4.1.15497.1.1.2.5 - memoryUtilizationExceeded
1.3.6.1.4.1.15497.1.1.2.9 - powerSupplyStatusChange
1.3.6.1.4.1.15497.1.1.2.2 - raidStatusChange
1.3.6.1.4.1.15497.1.1.2.7 - resourceConservationMode
1.3.6.1.4.1.15497.1.1.2.1 - updateFailure
1.3.6.1.4.1.15497.1.1.2.6