OCCAM-MLT-MIB
Occam Networks, Inc.This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
snmptranslate -m OCCAM-MLT-MIB -Tpsnmpwalk -v2c -c <community> -m OCCAM-MLT-MIB <host> 1.3.6.1.4.1.6066.2.1.1.3Imports
| OCCAM-REG-MODULE | occamGenericMonitorModules |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IoccamMltMib | 1.3.6.1.4.1.6066.2.1.1.3 | |||
identity This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results. | ||||
| NmltTestConfig | 1.3.6.1.4.1.6066.2.1.1.3.1 | |||
| SmltTestIdentifier | 1.3.6.1.4.1.6066.2.1.1.3.1.1 | MltTestIdentifier | RW | |
scalar · MltTestIdentifier · read-write · current Selects the mlt test to be run.
Setting this value starts a test.
This is a required parameter.
Approximate expected test durations are as
follows:
statusSuite 1 second
mltSuite 1 minute
activeModeVoltages 3 seconds
highImpedanceModeVoltages 9 seconds
dcResistance 18 seconds
capacitance 18 seconds
loopDetect 9 seconds
loopLength 9 seconds. | ||||
| SmltTestType | 1.3.6.1.4.1.6066.2.1.1.3.1.2 | MltTestType | RW | |
scalar · MltTestType · read-write · current Selects if a test is requested (only run if port
is not in use) or forced.
This is an optional parameter. If not specified,
the request option is used. | ||||
| SmltTestPort | 1.3.6.1.4.1.6066.2.1.1.3.1.3 | Integer32 (1..48) | RW | |
scalar · Integer32 (1..48) · read-write · current Selects voice channel on which test will be run. This is a required parameter. | ||||
| SmltDcResistanceRange | 1.3.6.1.4.1.6066.2.1.1.3.1.4 | Integer32 (0..3) | RW | |
scalar · Integer32 (0..3) · read-write · current Selects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode). | ||||
| SmltLoopLengthMultiplier | 1.3.6.1.4.1.6066.2.1.1.3.1.5 | Integer32 (10..200) | RW | |
scalar · Integer32 (10..200) · read-write · current Selects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used. | ||||
| SmltLoopDetectThreshold | 1.3.6.1.4.1.6066.2.1.1.3.1.6 | Integer32 (5..200) | RW | |
scalar · Integer32 (5..200) · read-write · current Selects the detection threshold in nF.
This is an optional parameter. If not supplied,
a loop detection threshold of 10nF is used. | ||||
| NmltTestStatus | 1.3.6.1.4.1.6066.2.1.1.3.2 | |||
| SmltLastTestStatus | 1.3.6.1.4.1.6066.2.1.1.3.2.1 | MltTestStatus | RO | |
scalar · MltTestStatus · read-only · current Indicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls be spaced 10-20 seconds apart. Additionally, a monitoring application could wait for the testComplete notification. | ||||
| SmltErrorText | 1.3.6.1.4.1.6066.2.1.1.3.2.2 | OCTET STRING | RO | |
scalar · OCTET STRING · read-only · current Indicates the textual error in the case of an aborted test. | ||||
| NmltTestResults | 1.3.6.1.4.1.6066.2.1.1.3.3 | |||
| TmltStatusResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.1 | NA | ||
table · not-accessible · current This table provides result of the status test suite. | ||||
| RmltStatusResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1 | NA | ||
row · not-accessible · current Entry holding information about results
of status suite tests.
Note that a numerical result value of -999 means
that there was an error of some sort and the
value could not be measured.
| ||||
| CmltStatusAlarm | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.1 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when status test was run. | ||||
| CmltStatusHookState | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.2 | MltTestHookState | RO | |
column · MltTestHookState · read-only · current Indicates line hook state when status test was run. | ||||
| CmltStatusTransversalCurrent | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current Indicates transversal current when status test was run.
| ||||
| CmltStatusLongitudinalCurrent | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current Indicates Longitudinal current when status test was run.
| ||||
| CmltStatusTipVoltage | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current Indicates tip voltage when status test was run.
| ||||
| CmltStatusRingVoltage | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current Indicates ring voltage when status test was run.
| ||||
| CmltStatusTipRingVoltage | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.7 | Integer32 | RO | |
column · Integer32 · read-only · current Indicates tip-ring voltage when status test was run.
| ||||
| CmltStatusVdd | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current Indicates Vdd when status test was run.
| ||||
| TmltTestResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.2 | NA | ||
table · not-accessible · current This table provides result of the mlt test suite.
Note that a numerical result value of -999 means
that there was an error of some sort and the
value could not be measured.
Also, a resistance value of 9999 means that the
result was greater than 1000 kOhms, but the exact
value could not be measured. | ||||
| RmltTestResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1 | NA | ||
row · not-accessible · current Entry holding information about results of mlt suite tests.
| ||||
| CmltTestAlarm | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.1 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current GNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuSLIC is experiencing thermal overload. This parameter is non-intrusive. | ||||
| CmltTestHookState | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.2 | MltTestHookState | RO | |
column · MltTestHookState · read-only · current Hook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive. | ||||
| CmltTestVdd | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current On HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be available during onhook.
| ||||
| CmltTestActiveModeVoltagesVdctr | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestActiveModeVoltagesVdctg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestActiveModeVoltagesVdcrg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestActiveModeVoltagesVactr | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.7 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestActiveModeVoltagesVactg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.8 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring
in a normal no shutdown state. Thus, VT and VR
measurements should be 0 volt. AC voltages for T-R, T-G
and R-G will be reported. Active mode measurements will
not be available when alarm is detected. This parameter
is intrusive and will be available in shutdown state
only.
| ||||
| CmltTestActiveModeVoltagesVacrg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.9 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestHighImpedanceModeVoltagesVdctr | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.10 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestHighImpedanceModeVoltagesVdctg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.11 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestHighImpedanceModeVoltagesVdcrg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.12 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestHighImpedanceModeVoltagesVactr | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.13 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestHighImpedanceModeVoltagesVactg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.14 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestHighImpedanceModeVoltagesVacrg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.15 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltTestDcCurrentsItransversal | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.16 | Integer32 | RO | |
column · Integer32 · read-only · current Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
| ||||
| CmltTestDcCurrentsIlongitudinal | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.17 | Integer32 | RO | |
column · Integer32 · read-only · current Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
| ||||
| CmltTestDcCurrentsItip | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.18 | Integer32 | RO | |
column · Integer32 · read-only · current Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
| ||||
| CmltTestDcCurrentsIring | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19 | Integer32 | RO | |
column · Integer32 · read-only · current Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
| ||||
| CmltTestCapacitanceCeqtr | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.20 | Integer32 | RO | |
column · Integer32 · read-only · current Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only.
| ||||
| CmltTestCapacitanceCeqtg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.21 | Integer32 | RO | |
column · Integer32 · read-only · current Capacitance measurements will support only single
element (2 terminal)
circuit. In the presence of a network of capacitance
(figure 3), the
individual capacitance will not be resolved. The
equivalent capacitances CEQtr, CEQtg and CEQrg will be
reported. They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only.
| ||||
| CmltTestCapacitanceCeqrg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.22 | Integer32 | RO | |
column · Integer32 · read-only · current Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only.
| ||||
| CmltTestResistanceRtr | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.23 | Integer32 | RO | |
column · Integer32 · read-only · current DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state ` only.
| ||||
| CmltTestResistanceRtg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.24 | Integer32 | RO | |
column · Integer32 · read-only · current DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltTestResistanceRrg | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25 | Integer32 | RO | |
column · Integer32 · read-only · current DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltTestGr909HazardousPotentialTestResult | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26 | MltTestPassFail | RO | |
column · MltTestPassFail · read-only · current This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only. | ||||
| CmltTestGr909ForeignEmfTestResult | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.27 | MltTestPassFail | RO | |
column · MltTestPassFail · read-only · current This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only. | ||||
| CmltTestGr909FuseTestTipFuse | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.28 | MltTestPassFail | RO | obsolete |
column · MltTestPassFail · read-only · obsolete This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed. | ||||
| CmltTestGr909FuseTestRingFuse | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.29 | MltTestPassFail | RO | obsolete |
column · MltTestPassFail · read-only · obsolete This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed. | ||||
| CmltTestGr909ResistiveFaultTestResult | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.30 | MltTestPassFail | RO | |
column · MltTestPassFail · read-only · current This test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test will return pass/fail. This test is intrusive and will be available in shutdown state only. | ||||
| CmltTestGr909ReceiverOffhookTestResult | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.31 | MltTestPassFail | RO | |
column · MltTestPassFail · read-only · current This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. | ||||
| CmltTestGr909ReceiverOffhookTestResistance1 | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.32 | Integer32 | RO | |
column · Integer32 · read-only · current This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltTestGr909ReceiverOffhookTestResistance2 | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.33 | Integer32 | RO | |
column · Integer32 · read-only · current This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltTestGr909ReceiverOffhookTestDifference | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.34 | Integer32 | RO | |
column · Integer32 · read-only · current This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltTestGr909RingerTestResult | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.35 | MltTestRingerResult | RO | |
column · MltTestRingerResult · read-only · current This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only. | ||||
| CmltTestGr909RingerTestRen | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36 | Integer32 | RO | |
column · Integer32 · read-only · current This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.
| ||||
| CmltTestErrors | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.37 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when test was run. | ||||
| CmltTestFuseTestTipFuse | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.38 | MltTestPassFail | RO | |
column · MltTestPassFail · read-only · current This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | ||||
| CmltTestFuseTestRingFuse | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.39 | MltTestPassFail | RO | |
column · MltTestPassFail · read-only · current This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | ||||
| TmltActiveModeVoltagesResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.3 | NA | ||
table · not-accessible · current This table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | ||||
| RmltActiveModeVoltagesResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1 | NA | ||
row · not-accessible · current Entry holding information about results of mlt active mode voltages test.
| ||||
| CmltActiveModeVoltagesVdctr | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.1 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltActiveModeVoltagesVdctg | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltActiveModeVoltagesVdcrg | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltActiveModeVoltagesVactr | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltActiveModeVoltagesVactg | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages:
In active mode, the DuSLIC drives the tip/ring in a
normal no shutdown state. Thus, VT and VR measurements
should be 0 volt. AC voltages for T-R, T-G and R-G will
be reported. Active mode measurements will not be
available when alarm is detected. This parameter is
intrusive and will be available in shutdown state only.
| ||||
| CmltActiveModeVoltagesVacrg | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltActiveModeVoltagesErrors | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.7 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when test was run. | ||||
| TmltHighImpedanceModeVoltagesResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.4 | NA | ||
table · not-accessible · current This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | ||||
| RmltHighImpedanceModeVoltagesResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1 | NA | ||
row · not-accessible · current Entry holding information about results of mlt high impedance mode voltages test.
| ||||
| CmltHighImpedanceModeVoltagesVdctr | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.1 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltHighImpedanceModeVoltagesVdctg | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltHighImpedanceModeVoltagesVdcrg | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltHighImpedanceModeVoltagesVactr | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltHighImpedanceModeVoltagesVactg | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltHighImpedanceModeVoltagesVacrg | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.6 | Integer32 | RO | |
column · Integer32 · read-only · current High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
| ||||
| CmltHighImpedanceModeVoltagesErrors | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.7 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when test was run. | ||||
| TmltDcResistanceResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.5 | NA | ||
table · not-accessible · current This table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured. | ||||
| RmltDcResistanceResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1 | NA | ||
row · not-accessible · current Entry holding information about results of mlt DC resistance test.
| ||||
| CmltDcResistanceRtr | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.1 | Integer32 | RO | |
column · Integer32 · read-only · current DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltDcResistanceRtg | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltDcResistanceRrg | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltDcResistanceErrors | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.4 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when test was run. | ||||
| TmltCapacitanceResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.6 | NA | ||
table · not-accessible · current This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | ||||
| RmltCapacitanceResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1 | NA | ||
row · not-accessible · current Entry holding information about results of mlt capacitance test.
| ||||
| CmltCapacitanceCeqtr | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.1 | Integer32 | RO | |
column · Integer32 · read-only · current Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only.
| ||||
| CmltCapacitanceCeqtg | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only.
| ||||
| CmltCapacitanceCeqrg | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current Capacitance measurements will support only single
element (2 terminal) circuit. In the presence of a
network of capacitance (figure 3), the individual
capacitance will not be resolved. The equivalent
capacitances CEQtr, CEQtg and CEQrg will be reported.
They represent the following:
CEQtr = Ctr + Ctg/4 + Crg/4
CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg)
CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg)
Capacitance measurements will not be available if fuse
test fails or alarm is present. This test is intrusive
and will be available in shutdown state only.
| ||||
| CmltCapacitanceErrors | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.4 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when test was run. | ||||
| TmltLoopDetectResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.7 | NA | ||
table · not-accessible · current This table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | ||||
| RmltLoopDetectResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1 | NA | ||
row · not-accessible · current Entry holding information about results of mlt loop detect test.
| ||||
| CmltLoopDetectLoopCapacitance | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.1 | Integer32 | RO | |
column · Integer32 · read-only · current Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltLoopDetectDetectionThreshold | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltLoopDetectLoopDetected | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.3 | MltTestYesNo | RO | |
column · MltTestYesNo · read-only · current Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | ||||
| CmltLoopDetectErrors | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.4 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when test was run. | ||||
| TmltLoopLengthResultsTable | 1.3.6.1.4.1.6066.2.1.1.3.3.8 | NA | ||
table · not-accessible · current This table provides result of the mlt loop length test.
Note that a numerical result value of -999 means that
there was an error of some sort and the value could
not be measured. | ||||
| RmltLoopLengthResultsEntry | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1 | NA | ||
row · not-accessible · current Entry holding information about results of mlt loop length test.
| ||||
| CmltLoopLengthCapacitanceFactor | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.1 | Integer32 | RO | |
column · Integer32 · read-only · current Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltLoopLengthLoopCapacitance | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.2 | Integer32 | RO | |
column · Integer32 · read-only · current Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltLoopLengthLoopLength | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.3 | Integer32 | RO | |
column · Integer32 · read-only · current Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
| ||||
| CmltLoopLengthUncompensatedLoopCapacitance | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.4 | Integer32 | RO | |
column · Integer32 · read-only · current Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.
| ||||
| CmltLoopLengthUncompensatedLoopLength | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.5 | Integer32 | RO | |
column · Integer32 · read-only · current Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.
| ||||
| CmltLoopLengthErrors | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.6 | OCTET STRING | RO | |
column · OCTET STRING · read-only · current Indicates GNK and/or OTEMP alarms active when test was run. | ||||
| NmltTestNotifications | 1.3.6.1.4.1.6066.2.1.1.3.4 | |||
| !mltTestCompletedNotification | 1.3.6.1.4.1.6066.2.1.1.3.4.1 | |||
notification · current This notification is sent to the requesting host when the requested mlt test has completed. | ||||
Textual conventions
MltTestHookStateINTEGERnotAvailable(3)offhook(2)onhook(1)An mlt test hook state value.
MltTestIdentifierINTEGERactiveModeVoltages(3)capacitance(6)dcResistance(5)highImpedanceModeVoltages(4)loopDetect(7)loopLength(8)mltSuite(2)statusSuite(1)An mlt test selection value.
MltTestPassFailINTEGERfail(2)notAvailable(3)pass(1)An mlt test pass/fail value.
MltTestRingerResultINTEGERfail(2)low(4)notAvailable(3)pass(1)An mlt ringer test result value.
MltTestStatusINTEGERcomplete(3)inProgress(5)mltBusy(2)mltError(6)mltNotResponding(7)none(1)portInUse(4)An indication of test status: none = no test has been requested. mltbusy = another port is currently being tested. complete = the last requested test has completed. portInUse = the last requested port is in use, the test was not run. Rerunning the test as 'forced' will shut the port and run the test. inProgress = the last requested test is still running. mltError = the mlt program reported an error and aborted the test.Check the mltErrorText object. mltNotResponding = the mlt program didn't return a result.MltTestTypeINTEGERforce(2)request(1)A selection value for requesting or forcing a test. A requested test will only run if the port is not in use. A forced test will immediately shut the port and run the test.
MltTestYesNoINTEGERno(2)notAvailable(3)yes(1)An mlt test pass/fail value.
Traps / Notifications
- mltTestCompletedNotification
1.3.6.1.4.1.6066.2.1.1.3.4.1