MIB Browser

BLUECOAT-SG-SENSOR-MIB

CacheFlow Inc.
The sensor MIB is used to monitor
the values of sensors
Organization
Blue Coat Systems, Inc.
Root OID
1.3.6.1.4.1.3417.2.1
Last updated
Objects
17
Source
Show full MIB
snmptranslate -m BLUECOAT-SG-SENSOR-MIB -Tp
snmpwalk -v2c -c <community> -m BLUECOAT-SG-SENSOR-MIB <host> 1.3.6.1.4.1.3417.2.1

Imports

BLUECOAT-MIBblueCoatMgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION, TimeStamp, TruthValue

OID tree

NameOIDTypeAccessStatus
IdeviceSensorMIB1.3.6.1.4.1.3417.2.1
NdeviceSensorMIBObjects1.3.6.1.4.1.3417.2.1.1
NdeviceSensorValues1.3.6.1.4.1.3417.2.1.1.1
TdeviceSensorValueTable1.3.6.1.4.1.3417.2.1.1.1.1NA
RdeviceSensorValueEntry1.3.6.1.4.1.3417.2.1.1.1.1.1NA
CdeviceSensorIndex1.3.6.1.4.1.3417.2.1.1.1.1.1.1Integer32 (1..2147483647)NA
CdeviceSensorTrapEnabled1.3.6.1.4.1.3417.2.1.1.1.1.1.2TruthValueRO
CdeviceSensorUnits1.3.6.1.4.1.3417.2.1.1.1.1.1.3SensorUnitsRO
CdeviceSensorScale1.3.6.1.4.1.3417.2.1.1.1.1.1.4ExpBase10RO
CdeviceSensorValue1.3.6.1.4.1.3417.2.1.1.1.1.1.5SensorValueRO
CdeviceSensorCode1.3.6.1.4.1.3417.2.1.1.1.1.1.6SensorCodeRO
CdeviceSensorStatus1.3.6.1.4.1.3417.2.1.1.1.1.1.7SensorStatusRO
CdeviceSensorTimeStamp1.3.6.1.4.1.3417.2.1.1.1.1.1.8TimeStampRO
CdeviceSensorName1.3.6.1.4.1.3417.2.1.1.1.1.1.9DisplayStringRO
NdeviceSensorMIBNotifications1.3.6.1.4.1.3417.2.1.2
NdeviceSensorMIBNotificationsPrefix1.3.6.1.4.1.3417.2.1.2.0
!deviceSensorTrap1.3.6.1.4.1.3417.2.1.2.0.1

Textual conventions

ExpBase10 Integer32 (-24..24)

Display hint: d

Exponent base 10 for the current sensor value.
For example '-1' means value*(1/10).
SensorCode INTEGER

fanSlowCritical(14) fanSlowWarning(13) fanStopped(15) noPower(6) notInstalled(3) ok(1) temperatureHighCritical(11) temperatureHighSevere(12) temperatureHighWarning(10) unknown(2) voltageHighCritical(8) voltageHighSevere(9) voltageHighWarning(7) voltageLowCritical(5) voltageLowWarning(4)

Interpretation of the current sensor value.
SensorStatus INTEGER

nonoperational(3) notInstalled(4) ok(1) unavailable(2)

Indicates the operational status of the sensor.
ok(1) means the agent can read the sensor value.
unavailable(2) means that the agent presently
can not report the sensor value.
nonoperational(3) means that the sensor is broken.
notInstalled(4) means that the sensor or device is not present.
SensorUnits INTEGER

celsius(5) other(1) rpm(6) specialEnum(3) truthvalue(2) volts(4)

Sensor measurement unit types. Valid values are:
other(1)        - a measure other than those listed below.
truthvalue(2)   - value takes { true(1), false(2) }.
specialEnum(3)  - value takes user defined enumerated values.
volts(4)        - electrical potential.
celsius(5)      - temperature.
rpm(6)          - revolutions per minute.
SensorValue Integer32 (-1000000000..1000000000)

Display hint: d

For sensors that measure volts and celsius,
this item is a fixed point number.
For sensors that measure rpm, this item
can take only nonnegative values.
For sensors of type truthvalue, this item
can take only two values: true(1), false(2).
For sensors of type specialEnum, this item
can take any value.

Traps / Notifications