BKTEL-HFC862-HMSNE-MIB
HUBER+SUHNER BKtel GmbH (HFC)snmptranslate -m BKTEL-HFC862-HMSNE-MIB -Tpsnmpwalk -v2c -c <community> -m BKTEL-HFC862-HMSNE-MIB <host> 1.3.6.1.4.1.7501.1.1.1Imports
| BKTEL-HFC862-BASE-MIB | DisplayString, NESlotValue, PerceivedSeverityValue, TruthValue, ne |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| !neSynchronizeEvent | 1.3.6.1.4.1.7501.1.1.0.1 | ||||||||||||
notification The SNMP trap that is generated when data on LMT must get actualized. | |||||||||||||
| NneCommon | 1.3.6.1.4.1.7501.1.1.1 | ||||||||||||
| SneType | 1.3.6.1.4.1.7501.1.1.1.1 | DisplayString | RO | mandatory | |||||||||
scalar · DisplayString · read-only · mandatory Type of NE | |||||||||||||
| SneDescription | 1.3.6.1.4.1.7501.1.1.1.2 | DisplayString | RO | mandatory | |||||||||
scalar · DisplayString · read-only · mandatory The description of the NE. | |||||||||||||
| SneLocationStreet | 1.3.6.1.4.1.7501.1.1.1.3 | DisplayString | RW | mandatory | |||||||||
scalar · DisplayString · read-write · mandatory Location Street of Network Element. Writable size depends on net element controller, default 32 | |||||||||||||
| SneLocationCity | 1.3.6.1.4.1.7501.1.1.1.4 | DisplayString | RW | mandatory | |||||||||
scalar · DisplayString · read-write · mandatory Location City of Network Element. Writable size depends on net element controller, default 32 | |||||||||||||
| SneObsolete_UsingAPS | 1.3.6.1.4.1.7501.1.1.1.5 | TruthValue | RO | obsolete | |||||||||
scalar · TruthValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneObsolete_APSMode | 1.3.6.1.4.1.7501.1.1.1.6 | INTEGER | RW | obsolete | |||||||||
scalar · INTEGER · read-write · obsolete This parameter is obsolete. | |||||||||||||
| SneObsolete_CommonSubrackWidth | 1.3.6.1.4.1.7501.1.1.1.8 | INTEGER | RO | obsolete | |||||||||
scalar · INTEGER · read-only · obsolete This parameter is obsolete. (The width of the Subracks) | |||||||||||||
| SneObsolete_CommonSubrackNumber | 1.3.6.1.4.1.7501.1.1.1.9 | INTEGER | RO | obsolete | |||||||||
scalar · INTEGER · read-only · obsolete This parameter is obsolete. (The number of Subracks) | |||||||||||||
| SneObsolete_NumberModul | 1.3.6.1.4.1.7501.1.1.1.10 | INTEGER (1..61) | RO | obsolete | |||||||||
scalar · INTEGER (1..61) · read-only · obsolete This parameter is obsolete. (Current number of entries in the Modul table) | |||||||||||||
| SneObsolete_UsingRevertiveMode | 1.3.6.1.4.1.7501.1.1.1.11 | TruthValue | RO | obsolete | |||||||||
scalar · TruthValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneObsolete_RevertiveMode | 1.3.6.1.4.1.7501.1.1.1.12 | INTEGER (0..300) | RW | obsolete | |||||||||
scalar · INTEGER (0..300) · read-write · obsolete This parameter is obsolete. | |||||||||||||
| SneObsolete_InitPhase | 1.3.6.1.4.1.7501.1.1.1.13 | INTEGER | RO | obsolete | |||||||||
scalar · INTEGER · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneObsolete_PredecessorRedundantPath | 1.3.6.1.4.1.7501.1.1.1.14 | IpAddress | RW | obsolete | |||||||||
scalar · IpAddress · read-write · obsolete This parameter is obsolete. | |||||||||||||
| SneObsolete_PredecessorNominalPath | 1.3.6.1.4.1.7501.1.1.1.15 | IpAddress | RW | obsolete | |||||||||
scalar · IpAddress · read-write · obsolete This parameter is obsolete. | |||||||||||||
| TneModuleTable | 1.3.6.1.4.1.7501.1.1.1.16 | NA | mandatory | ||||||||||
table · not-accessible · mandatory Table containing information about each Module. | |||||||||||||
| RneModuleEntry | 1.3.6.1.4.1.7501.1.1.1.16.1 | NA | mandatory | ||||||||||
| CneModuleNESlot | 1.3.6.1.4.1.7501.1.1.1.16.1.1 | NESlotValue | RO | mandatory | |||||||||
column · NESlotValue · read-only · mandatory Slot number IMPORTANT NOTE: this is a not a physical slot within a module rack, but an assigned slot ID that uniquely identifies each module including non subrack based modules as 19 inch modules | |||||||||||||
| CneModuleSubrack | 1.3.6.1.4.1.7501.1.1.1.16.1.2 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory Subrack number in which the module is equiped (1 .. N). A value of 0 means: No subrack number | |||||||||||||
| CneModuleModelName | 1.3.6.1.4.1.7501.1.1.1.16.1.3 | DisplayString | RO | mandatory | NECE-E | ||||||||
column · DisplayString · read-only · mandatory Module model name Example values from LibreNMS test devices
| |||||||||||||
| CneModuleMibLink | 1.3.6.1.4.1.7501.1.1.1.16.1.4 | OBJECT IDENTIFIER | RO | mandatory | |||||||||
column · OBJECT IDENTIFIER · read-only · mandatory Defines the link to the OID of the equiped module | |||||||||||||
| CneModuleSubrackSlot | 1.3.6.1.4.1.7501.1.1.1.16.1.5 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory Slot number within subrack in which the module is equiped (1 .. N). A value of 0 means: No slot number | |||||||||||||
| CneModuleSlotUnitsUsed | 1.3.6.1.4.1.7501.1.1.1.16.1.6 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. For all other module types the number of slots within subrack which the module occupies. | |||||||||||||
| CneModuleSlotRackDetection | 1.3.6.1.4.1.7501.1.1.1.16.1.7 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory Reports the state of modules slot and rack hardware detection.
| |||||||||||||
| CneModuleHousingType | 1.3.6.1.4.1.7501.1.1.1.16.1.8 | INTEGER | RO | mandatory | |||||||||
column · INTEGER · read-only · mandatory Module housing type
| |||||||||||||
| CneModuleFirmwareVersion | 1.3.6.1.4.1.7501.1.1.1.16.1.9 | DisplayString | RO | mandatory | |||||||||
column · DisplayString · read-only · mandatory Module firmware version | |||||||||||||
| CneModuleHardwareVersion | 1.3.6.1.4.1.7501.1.1.1.16.1.10 | DisplayString | RO | mandatory | |||||||||
column · DisplayString · read-only · mandatory Module hardware version | |||||||||||||
| CneModuleDateOfProduction | 1.3.6.1.4.1.7501.1.1.1.16.1.11 | DisplayString | RO | mandatory | |||||||||
column · DisplayString · read-only · mandatory Module date of production, possible formats: - empty string -> no data defined - YYYY -> only the year of production is defined - YYYY-MM-DD -> full date of production is defined | |||||||||||||
| CneModuleSerialNumber | 1.3.6.1.4.1.7501.1.1.1.16.1.12 | DisplayString | RO | mandatory | |||||||||
column · DisplayString · read-only · mandatory Module serial number | |||||||||||||
| CneModuleArticleNumber | 1.3.6.1.4.1.7501.1.1.1.16.1.13 | DisplayString | RO | mandatory | |||||||||
column · DisplayString · read-only · mandatory Module article number | |||||||||||||
| CneModuleCustomerCode | 1.3.6.1.4.1.7501.1.1.1.16.1.14 | DisplayString | RO | mandatory | |||||||||
column · DisplayString · read-only · mandatory Customer specific article code | |||||||||||||
| CneModuleAliasName | 1.3.6.1.4.1.7501.1.1.1.16.1.15 | DisplayString | RW | mandatory | |||||||||
column · DisplayString · read-write · mandatory Module alias name | |||||||||||||
| CneModuleUserdata | 1.3.6.1.4.1.7501.1.1.1.16.1.16 | DisplayString | RW | mandatory | |||||||||
column · DisplayString · read-write · mandatory Module user data | |||||||||||||
| CneModuleReset | 1.3.6.1.4.1.7501.1.1.1.16.1.17 | TruthValue | RW | mandatory | |||||||||
column · TruthValue · read-write · mandatory Resets the module if this parameter is written to true(1). | |||||||||||||
| CneModuleLedBlink | 1.3.6.1.4.1.7501.1.1.1.16.1.18 | TruthValue | RW | mandatory | |||||||||
column · TruthValue · read-write · mandatory Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stops blinking at once. This variable always returns false(2) on read requests | |||||||||||||
| NneStates | 1.3.6.1.4.1.7501.1.1.2 | ||||||||||||
| SneStatesObsolete_TrapDisable | 1.3.6.1.4.1.7501.1.1.2.1 | PerceivedSeverityValue | RO | obsolete | |||||||||
scalar · PerceivedSeverityValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneStatesObsolete_TerminalConnected | 1.3.6.1.4.1.7501.1.1.2.2 | PerceivedSeverityValue | RO | obsolete | |||||||||
scalar · PerceivedSeverityValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneStatesObsolete_Isolated | 1.3.6.1.4.1.7501.1.1.2.4 | PerceivedSeverityValue | RO | obsolete | |||||||||
scalar · PerceivedSeverityValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneStatesObsolete_ResetModullist | 1.3.6.1.4.1.7501.1.1.2.5 | PerceivedSeverityValue | RO | obsolete | |||||||||
scalar · PerceivedSeverityValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneStatesObsolete_Redundant | 1.3.6.1.4.1.7501.1.1.2.6 | PerceivedSeverityValue | RO | obsolete | |||||||||
scalar · PerceivedSeverityValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneStatesObsolete_ActivateRedundantPath | 1.3.6.1.4.1.7501.1.1.2.7 | PerceivedSeverityValue | RO | obsolete | |||||||||
scalar · PerceivedSeverityValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| SneStatesObsolete_AutoOff | 1.3.6.1.4.1.7501.1.1.2.8 | PerceivedSeverityValue | RO | obsolete | |||||||||
scalar · PerceivedSeverityValue · read-only · obsolete This parameter is obsolete. | |||||||||||||
| NneConfig | 1.3.6.1.4.1.7501.1.1.3 | ||||||||||||
| SneConfigObsolete_NEtype | 1.3.6.1.4.1.7501.1.1.3.1 | INTEGER | RW | obsolete | |||||||||
scalar · INTEGER · read-write · obsolete This parameter is obsolete. | |||||||||||||
| SneConfigObsolete_IPaddress | 1.3.6.1.4.1.7501.1.1.3.2 | IpAddress | RW | obsolete | |||||||||
scalar · IpAddress · read-write · obsolete This parameter is obsolete. | |||||||||||||
| SneConfigObsolete_Alarmdelay | 1.3.6.1.4.1.7501.1.1.3.3 | INTEGER (3..60) | RW | obsolete | |||||||||
scalar · INTEGER (3..60) · read-write · obsolete This parameter is obsolete. | |||||||||||||
| SneConfigDeprecated_MinTrapInterval | 1.3.6.1.4.1.7501.1.1.3.4 | INTEGER (0..10) | RW | optional | |||||||||
scalar · INTEGER (0..10) · read-write · optional This parameter is deprecated. (The minimum waiting time between two traps. Only used for HMS070 over RS232 interface) | |||||||||||||
| SneConfigDeprecated_MaxTrapLifetime | 1.3.6.1.4.1.7501.1.1.3.5 | INTEGER (30..300) | RW | optional | |||||||||
scalar · INTEGER (30..300) · read-write · optional This parameter is deprecated. (The maximum lifetime of a trap. Only used for HMS070 over RS232 interface) | |||||||||||||
| NneControl | 1.3.6.1.4.1.7501.1.1.4 | ||||||||||||
| SneControlTrapDisable | 1.3.6.1.4.1.7501.1.1.4.1 | TruthValue | RW | mandatory | |||||||||
scalar · TruthValue · read-write · mandatory All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2) | |||||||||||||
| SneControlResetModullist | 1.3.6.1.4.1.7501.1.1.4.2 | TruthValue | RW | mandatory | |||||||||
scalar · TruthValue · read-write · mandatory This command removes all disconnected (not responding) modules from the module list. | |||||||||||||
| SneControlObsolete_SetDefaultAPS | 1.3.6.1.4.1.7501.1.1.4.3 | TruthValue | RW | obsolete | |||||||||
scalar · TruthValue · read-write · obsolete This parameter is obsolete. | |||||||||||||
Traps / Notifications
- neSynchronizeEvent
1.3.6.1.4.1.7501.1.1.0.1