BKTEL-HFC862-BES-V01-MIB
HUBER+SUHNER BKtel GmbH (HFC)snmptranslate -m BKTEL-HFC862-BES-V01-MIB -Tpsnmpwalk -v2c -c <community> -m BKTEL-HFC862-BES-V01-MIB <host> 1.3.6.1.4.1.7501.1.2.114Imports
| BKTEL-HFC862-BASE-MIB | DisplayString, ModuleWidthValue, NESlotValue, PerceivedSeverityValue, TruthValue, modules |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, experimental, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Nbes | 1.3.6.1.4.1.7501.1.2.114 | |||
| NbesCommon | 1.3.6.1.4.1.7501.1.2.114.1 | |||
| SbesCommonNumberOfModules | 1.3.6.1.4.1.7501.1.2.114.1.1 | INTEGER (0..50) | RO | mandatory |
scalar · INTEGER (0..50) · read-only · mandatory Number of modules in table. | ||||
| TbesCommonTable | 1.3.6.1.4.1.7501.1.2.114.1.2 | NA | mandatory | |
table · not-accessible · mandatory The table contains all modules of the BES-type in the NE | ||||
| RbesCommonEntry | 1.3.6.1.4.1.7501.1.2.114.1.2.1 | NA | mandatory | |
| CbesNESlot | 1.3.6.1.4.1.7501.1.2.114.1.2.1.1 | NESlotValue | RO | mandatory |
column · NESlotValue · read-only · mandatory The slot number of the chassis for which this entry contains management information. | ||||
| CbesCommonType | 1.3.6.1.4.1.7501.1.2.114.1.2.1.2 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory The type of physical module. modSlotEmpty indicates an empty slot. A Value of modSlotUnknown indicates that the type of module is unknown. | ||||
| CbesCommonDescr | 1.3.6.1.4.1.7501.1.2.114.1.2.1.3 | DisplayString | RW | mandatory |
column · DisplayString · read-write · mandatory A textual description of the module. If not available, this Value should be set to a zero length string. | ||||
| CbesCommonFirmwareId | 1.3.6.1.4.1.7501.1.2.114.1.2.1.4 | DisplayString (SIZE (0..32)) | RO | mandatory |
column · DisplayString (SIZE (0..32)) · read-only · mandatory The firmware Id of the module. | ||||
| CbesCommonModuleWidth | 1.3.6.1.4.1.7501.1.2.114.1.2.1.5 | ModuleWidthValue | RO | optional |
column · ModuleWidthValue · read-only · optional The width of the module in multiples of slots (1, 2, ...) | ||||
| NbesStates | 1.3.6.1.4.1.7501.1.2.114.2 | |||
| TbesStatesTable | 1.3.6.1.4.1.7501.1.2.114.2.1 | NA | mandatory | |
| RbesStatesEntry | 1.3.6.1.4.1.7501.1.2.114.2.1.1 | NA | mandatory | |
| CbesStatesBootloader | 1.3.6.1.4.1.7501.1.2.114.2.1.1.1 | PerceivedSeverityValue | RO | mandatory |
column · PerceivedSeverityValue · read-only · mandatory The device is running in bootloader mode without a legal application software. | ||||
| CbesStatesCommLoss | 1.3.6.1.4.1.7501.1.2.114.2.1.1.2 | PerceivedSeverityValue | RO | mandatory |
column · PerceivedSeverityValue · read-only · mandatory The NEC has lost the connection to the device. Reason may be a removed or defective device. Note that this state is set by the NEC and not by the device | ||||
| CbesStatesTemperatureLow | 1.3.6.1.4.1.7501.1.2.114.2.1.1.3 | PerceivedSeverityValue | RO | mandatory |
column · PerceivedSeverityValue · read-only · mandatory Device temperature low | ||||
| CbesStatesTemperatureHigh | 1.3.6.1.4.1.7501.1.2.114.2.1.1.4 | PerceivedSeverityValue | RO | mandatory |
column · PerceivedSeverityValue · read-only · mandatory Device temperature high | ||||
| CbesStatesInputVoltageLow | 1.3.6.1.4.1.7501.1.2.114.2.1.1.5 | PerceivedSeverityValue | RO | mandatory |
column · PerceivedSeverityValue · read-only · mandatory Input supply voltage low | ||||
| CbesStatesInputVoltageHigh | 1.3.6.1.4.1.7501.1.2.114.2.1.1.6 | PerceivedSeverityValue | RO | mandatory |
column · PerceivedSeverityValue · read-only · mandatory Input supply voltage high | ||||
| NbesConfiguration | 1.3.6.1.4.1.7501.1.2.114.3 | |||
| TbesConfigurationTable | 1.3.6.1.4.1.7501.1.2.114.3.1 | NA | mandatory | |
| RbesConfigurationEntry | 1.3.6.1.4.1.7501.1.2.114.3.1.1 | NA | mandatory | |
row · not-accessible · mandatory
| ||||
| CbesConfigNESlotWrite | 1.3.6.1.4.1.7501.1.2.114.3.1.1.1 | NESlotWriteValue | RW | optional |
column · NESlotWriteValue · read-write · optional By writing this variable a slot can be assigned for devices that dont support hardware slot detection. Reading '-1' means that the slot position is NOT writable. | ||||
| CbesConfigConfigurationIndex | 1.3.6.1.4.1.7501.1.2.114.3.1.1.2 | INTEGER | RW | mandatory |
column · INTEGER · read-write · mandatory Index of the active configuration (1..besDisplayNumberOfConfigs) | ||||
| CbesConfigConfiguration | 1.3.6.1.4.1.7501.1.2.114.3.1.1.3 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of the active configuration | ||||
| NbesControl | 1.3.6.1.4.1.7501.1.2.114.4 | |||
| TbesControlTable | 1.3.6.1.4.1.7501.1.2.114.4.1 | NA | mandatory | |
| RbesControlEntry | 1.3.6.1.4.1.7501.1.2.114.4.1.1 | NA | mandatory | |
| CbesControlReset | 1.3.6.1.4.1.7501.1.2.114.4.1.1.1 | TruthValue | RW | mandatory |
column · TruthValue · read-write · mandatory Reset the module. | ||||
| CbesControlModuleLedBlink | 1.3.6.1.4.1.7501.1.2.114.4.1.1.2 | TruthValue | RW | mandatory |
column · TruthValue · read-write · mandatory Writing this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stbes blinking at once. This variable always returns false(2) on read requests | ||||
| NbesMeasuringValues | 1.3.6.1.4.1.7501.1.2.114.5 | |||
| TbesMeasuringValuesTable | 1.3.6.1.4.1.7501.1.2.114.5.1 | NA | mandatory | |
| RbesMeasuringValuesEntry | 1.3.6.1.4.1.7501.1.2.114.5.1.1 | NA | mandatory | |
| CbesTemperatureLoLo | 1.3.6.1.4.1.7501.1.2.114.5.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Device temperature low alarm threshold in 0.1 celsius degrees. | ||||
| CbesTemperatureLo | 1.3.6.1.4.1.7501.1.2.114.5.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Device temperature low warning threshold in 0.1 celsius degrees. | ||||
| CbesTemperatureValue | 1.3.6.1.4.1.7501.1.2.114.5.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Device temperature in 0.1 celsius degrees. | ||||
| CbesTemperatureHi | 1.3.6.1.4.1.7501.1.2.114.5.1.1.4 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Device temperature high warning threshold in 0.1 celsius degrees. | ||||
| CbesTemperatureHiHi | 1.3.6.1.4.1.7501.1.2.114.5.1.1.5 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Device temperature high alarm threshold in 0.1 celsius degrees. | ||||
| CbesInputVoltageLoLo | 1.3.6.1.4.1.7501.1.2.114.5.1.1.6 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The input supply voltage low alarm threshold in steps of 0.1 Volts. | ||||
| CbesInputVoltageLo | 1.3.6.1.4.1.7501.1.2.114.5.1.1.7 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The input supply voltage low warning threshold in steps of 0.1 Volts. | ||||
| CbesInputVoltageValue | 1.3.6.1.4.1.7501.1.2.114.5.1.1.8 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The input supply voltage in steps of 0.1 Volts. Input supply voltage nominal value, see 'besDisplayInputVoltageNominal' | ||||
| CbesInputVoltageHi | 1.3.6.1.4.1.7501.1.2.114.5.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The input supply voltage high warning threshold in steps of 0.1 Volts. | ||||
| CbesInputVoltageHiHi | 1.3.6.1.4.1.7501.1.2.114.5.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The input supply voltage high alarm threshold in steps of 0.1 Volts. | ||||
| NbesDisplay | 1.3.6.1.4.1.7501.1.2.114.6 | |||
| TbesDisplayTable | 1.3.6.1.4.1.7501.1.2.114.6.1 | NA | mandatory | |
| RbesDisplayEntry | 1.3.6.1.4.1.7501.1.2.114.6.1.1 | NA | mandatory | |
row · not-accessible · mandatory
| ||||
| CbesDisplayNumberOfPorts | 1.3.6.1.4.1.7501.1.2.114.6.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of ports | ||||
| CbesDisplayInputVoltageNominal | 1.3.6.1.4.1.7501.1.2.114.6.1.1.2 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The nominal value of input voltage in 0.1 V units. | ||||
| CbesDisplayNumberOfConfigs | 1.3.6.1.4.1.7501.1.2.114.6.1.1.3 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory The number of different configurations supplied | ||||
| CbesDisplayConfiguration1 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.4 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #1 | ||||
| CbesDisplayConfiguration2 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.5 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #2 | ||||
| CbesDisplayConfiguration3 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.6 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #3 | ||||
| CbesDisplayConfiguration4 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.7 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #4 | ||||
| CbesDisplayConfiguration5 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.8 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #5 | ||||
| CbesDisplayConfiguration6 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.9 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #6 | ||||
| CbesDisplayConfiguration7 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.10 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #7 | ||||
| CbesDisplayConfiguration8 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.11 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #8 | ||||
| CbesDisplayConfiguration9 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.12 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #9 | ||||
| CbesDisplayConfiguration10 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.13 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #10 | ||||
| CbesDisplayConfiguration11 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.14 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #11 | ||||
| CbesDisplayConfiguration12 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.15 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #12 | ||||
| CbesDisplayConfiguration13 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.16 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #13 | ||||
| CbesDisplayConfiguration14 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.17 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #14 | ||||
| CbesDisplayConfiguration15 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.18 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #15 | ||||
| CbesDisplayConfiguration16 | 1.3.6.1.4.1.7501.1.2.114.6.1.1.19 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Description of configuration no. #16 | ||||
| NbesDisplayPorts | 1.3.6.1.4.1.7501.1.2.114.56 | |||
| TbesDisplayPortsTable | 1.3.6.1.4.1.7501.1.2.114.56.1 | NA | mandatory | |
| RbesDisplayPortsEntry | 1.3.6.1.4.1.7501.1.2.114.56.1.1 | NA | mandatory | |
row · not-accessible · mandatory | ||||
| CbesDisplayPortsPortIndex | 1.3.6.1.4.1.7501.1.2.114.56.1.1.1 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port index (1..besDisplayNumberOfPorts) | ||||
| CbesDisplayPortsPortName | 1.3.6.1.4.1.7501.1.2.114.56.1.1.2 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Port name | ||||
| CbesDisplayPortsType | 1.3.6.1.4.1.7501.1.2.114.56.1.1.3 | PortType | RO | mandatory |
column · PortType · read-only · mandatory Port type | ||||
| CbesDisplayPortsLinkState | 1.3.6.1.4.1.7501.1.2.114.56.1.1.4 | PortLinkState | RO | mandatory |
column · PortLinkState · read-only · mandatory Port link status | ||||
| CbesDisplayPortsStatus | 1.3.6.1.4.1.7501.1.2.114.56.1.1.5 | PortStatus | RO | mandatory |
column · PortStatus · read-only · mandatory Port status | ||||
| CbesDisplayPortsDuplexMode | 1.3.6.1.4.1.7501.1.2.114.56.1.1.6 | PortDuplexMode | RO | mandatory |
column · PortDuplexMode · read-only · mandatory Port duplex mode | ||||
| CbesDisplayPortsSpeed | 1.3.6.1.4.1.7501.1.2.114.56.1.1.7 | PortSpeed | RO | mandatory |
column · PortSpeed · read-only · mandatory Port speed | ||||
| CbesDisplayPortsFlowControl | 1.3.6.1.4.1.7501.1.2.114.56.1.1.8 | PortFlowControl | RO | mandatory |
column · PortFlowControl · read-only · mandatory Port speed | ||||
| CbesDisplayPortsFiberTxDistance | 1.3.6.1.4.1.7501.1.2.114.56.1.1.9 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port transmission distance in units of km (Fiber ports only) | ||||
| CbesDisplayPortsFiberTxWavelen | 1.3.6.1.4.1.7501.1.2.114.56.1.1.10 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port transmission wavelength in units of nm (Fiber ports only) | ||||
| CbesDisplayPortsFiberRxWavelenMin | 1.3.6.1.4.1.7501.1.2.114.56.1.1.11 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port minimum receive wavelength in units of nm (Fiber ports only) | ||||
| CbesDisplayPortsFiberRxWavelenMax | 1.3.6.1.4.1.7501.1.2.114.56.1.1.12 | INTEGER | RO | mandatory |
column · INTEGER · read-only · mandatory Port maximum receive wavelength in units of nm (Fiber ports only) | ||||
| CbesDisplayPortsFiberSfpData | 1.3.6.1.4.1.7501.1.2.114.56.1.1.13 | DisplayString | RO | mandatory |
column · DisplayString · read-only · mandatory Port SFP data text (Fiber ports only) | ||||