AT-FIBER-MONITORING-MIB
Allied Telesis, Inc.This MIB contains managed objects definition and notification definitions for AT Fiber Monitoring feature.
snmptranslate -m AT-FIBER-MONITORING-MIB -Tpsnmpwalk -v2c -c <community> -m AT-FIBER-MONITORING-MIB <host> 1.3.6.1.4.1.207.8.4.4.3.27Imports
| AT-SYSINFO-MIB | sysinfo |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IatFiberMon | 1.3.6.1.4.1.207.8.4.4.3.27 | |||
identity This MIB contains managed objects definition and notification definitions for AT Fiber Monitoring feature. | ||||
| NatFiberMonNotifications | 1.3.6.1.4.1.207.8.4.4.3.27.0 | |||
| !atFiberMonAlarmSetNotify | 1.3.6.1.4.1.207.8.4.4.3.27.0.1 | |||
notification · current A notification generated when the monitored received optical power of an SFP goes outside its alarm threshold. | ||||
| !atFiberMonAlarmClearedNotify | 1.3.6.1.4.1.207.8.4.4.3.27.0.2 | |||
notification · current A notification generated when the monitored received optical power of an SFP returns to an acceptable value. This can occur because the power has returned to its previous level or the comparison baseline has adjusted to the new level. | ||||
| NatFiberMonTrapVariable | 1.3.6.1.4.1.207.8.4.4.3.27.1 | |||
| SatFiberMonReading | 1.3.6.1.4.1.207.8.4.4.3.27.1.1 | Integer32 (0..65535) | AN | |
scalar · Integer32 (0..65535) · accessible-for-notify · current The current received optical power reading for the port specified in the trap (x0.0001mW) | ||||
| TatFiberMonConfigTable | 1.3.6.1.4.1.207.8.4.4.3.27.2 | NA | ||
table · not-accessible · current It contains the objects used to configure the operation of fiber monitoring. | ||||
| RatFiberMonConfigEntry | 1.3.6.1.4.1.207.8.4.4.3.27.2.1 | NA | ||
row · not-accessible · current Entry for the table. It contains the configurables of fiber monitering for an interface.
| ||||
| CatFiberMonIfname | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.1 | OCTET STRING (SIZE (1..16)) | RW | |
column · OCTET STRING (SIZE (1..16)) · read-write · current The name of the interface where the pluggable is in. | ||||
| CatFiberMonEnable | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.2 | INTEGER | RW | |
column · INTEGER · read-write · current Enable or disable fiber monitoring.
| ||||
| CatFiberMonInterval | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.3 | Integer32 (2..60) | RW | |
column · Integer32 (2..60) · read-write · current Fiber monitoring polling interval in seconds. | ||||
| CatFiberMonSensitivity | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.4 | OCTET STRING | RW | |
column · OCTET STRING · read-write · current The sensitivity for fiber monitoring. Acceptable mode strings and value ranges are as below: low - 2dB medium - 1dB high - 0.5dB highest - 0.0025mW fixed <25 - 65535> - units of 0.0001mW relative <0.00 - 10.00> - units of dB For example, if you want to set the sensitivity to medium level, then you enter word medium Or if you want to set it to a fixed value, then you enter string fixed 1000 Or if you want to set to a relative value, then you enter string relative 1.20 | ||||
| CatFiberMonBaseline | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.5 | OCTET STRING | RW | |
column · OCTET STRING · read-write · current The baseline value for firber mornitoring. Acceptable mode string and value ranges are as below: average <12-150> - number of readings used to calculate moving average. fixed <1-65535> - fixed baseline value in units of 0.0001mW. For example, if you want to use a moving average of 12 readings as the baseline, you enter average 12 Or if you want to use a fixed value, though it is not recommended, you enter fixed 500 | ||||
| CatFiberMonAlarmAction | 1.3.6.1.4.1.207.8.4.4.3.27.2.1.6 | INTEGER | RW | |
column · INTEGER · read-write · current Actions to take when an alarm occurs. Acceptable values are: 1. Log a message only. 2. Send snmp trap and log. 3. Shut down the interface and log. 4. Send trap, shutdown and log.
| ||||
| TatFiberMonStateTable | 1.3.6.1.4.1.207.8.4.4.3.27.3 | NA | ||
table · not-accessible · current This table contains the information of fiber monitoring state for SFPs. | ||||
| RatFiberMonStateEntry | 1.3.6.1.4.1.207.8.4.4.3.27.3.1 | NA | ||
row · not-accessible · current Entry for fiber monitoring state table. It contains state values for a fiber channel. | ||||
| CatFiberMonIfindex | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.1 | Integer32 (1..2147483647) | RO | |
column · Integer32 (1..2147483647) · read-only · current The index of the interface where the pluggable is in. | ||||
| CatFiberMonChannel | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.2 | INTEGER (1..16) | RO | |
column · INTEGER (1..16) · read-only · current The channel number of the pluggable. | ||||
| CatFiberMonlIfDescription | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.3 | DisplayString | RO | |
column · DisplayString · read-only · current Interface description. Normally it would be the name of the interface. | ||||
| CatFiberMonActualBaseline | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.4 | Integer32 (0..65535) | RO | |
column · Integer32 (0..65535) · read-only · current The calculated baseline value for the link, in units of 0.0001mW. | ||||
| CatFiberMonThreshold | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.5 | Integer32 (0..65535) | RO | |
column · Integer32 (0..65535) · read-only · current Threshold value for alarm to occur, in units of 0.0001mW. | ||||
| CatFiberMonReadingHistory | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.6 | DisplayString | RO | |
column · DisplayString · read-only · current The reading history. It is a string containing last 12 readings. | ||||
| CatFiberMonMinReading | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.7 | Integer32 (0..65535) | RO | |
column · Integer32 (0..65535) · read-only · current The minimum reading of rx power, in units of 0.0001mW. | ||||
| CatFiberMonMaxReading | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.8 | Integer32 (0..65535) | RO | |
column · Integer32 (0..65535) · read-only · current The maximum reading of rx power, in units of 0.0001mW. | ||||
| CatFiberMonLastReading | 1.3.6.1.4.1.207.8.4.4.3.27.3.1.9 | Integer32 (-1..65535) | RO | |
column · Integer32 (-1..65535) · read-only · current The most recent reading of rx power, in units of 0.0001mW. -1 is returned if no readings have been taken yet. | ||||
Traps / Notifications
- atFiberMonAlarmClearedNotify
1.3.6.1.4.1.207.8.4.4.3.27.0.2 - atFiberMonAlarmSetNotify
1.3.6.1.4.1.207.8.4.4.3.27.0.1