ARUBAWIRED-LLDP-MIB
Hewlett Packard EnterpriseThis MIB module describes management objects that manage LLDP information related to Power Source Equipment (PSE). This is the MIB module related to HPE Aruba LLDP
snmptranslate -m ARUBAWIRED-LLDP-MIB -Tpsnmpwalk -v2c -c <community> -m ARUBAWIRED-LLDP-MIB <host> 1.3.6.1.4.1.47196.4.1.1.3.9Imports
| ARUBAWIRED-NETWORKING-OID | wndFeatures |
|---|---|
| LLDP-MIB | lldpLocPortNum, lldpRemIndex, lldpRemLocalPortNum, lldpRemTimeMark |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| IarubaWiredLldpMIB | 1.3.6.1.4.1.47196.4.1.1.3.9 | |||
identity This MIB module describes management objects that manage LLDP information related to Power Source Equipment (PSE). This is the MIB module related to HPE Aruba LLDP | ||||
| NarubaWiredLldpXdot3Objects | 1.3.6.1.4.1.47196.4.1.1.3.9.1 | |||
| NarubaWiredLldpXdot3LocalData | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1 | |||
| TarubaWiredLldpXdot3LocPowerTable | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1 | NA | ||
table · not-accessible · current This table contains one row per port of power ethernet information (as a part of the LLDP 802.3bt organizational extension) on the local system known to this agent. | ||||
| RarubaWiredLldpXdot3LocPowerEntry | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1 | NA | ||
| CarubaWiredLldpXdot3LocPowerPortClass | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.1 | INTEGER | RO | |
column · INTEGER · read-only · current The value that identifies the port Class of the given port associated with the local system.
| ||||
| CarubaWiredLldpXdot3LocPowerMDISupported | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.2 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate whether the MDI power is supported on the given port associated with the local system. | ||||
| CarubaWiredLldpXdot3LocPowerMDIEnabled | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.3 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate whether the MDI power is enabled on given port associated with the local system. | ||||
| CarubaWiredLldpXdot3LocPowerPairControlable | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.4 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate the ability to control which PSE Pinout Alternative is used for PD detection and power. | ||||
| CarubaWiredLldpXdot3LocPowerPairs | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current The truth value that identifies the PSE Pinout Alternative in use for detecting and supplying power to the PD.
| ||||
| CarubaWiredLldpXdot3LocPowerClass | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current The truth value that indicates the requested Class of the PD.
| ||||
| CarubaWiredLldpXdot3LocPowerType | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current This field reflects the actual local power type.
| ||||
| CarubaWiredLldpXdot3LocPowerSource | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current This field reflects the requested local device power source. When the power type is PSE, this field shall be set to primary(2) when the PSE is sourcing its power through the PI from its primary supply; to backup(3) when the PSE is sourcing its power through the PI from a backup source; and to unknown(1) when this information is not available.
| ||||
| CarubaWiredLldpXdot3LocPowerPriority | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.9 | INTEGER | RW | |
column · INTEGER · read-write · current This field reflects the requested local device power priority. When the power type is PD, this field shall be set to the power priority configured for the device. If a PD is unable to determine its power priority or it has not been configured, then this field shall be set to unknown(1). When the power type is PSE, this field shall be set to unknown(1).
| ||||
| CarubaWiredLldpXdot3LocPDRequestedPowerValue | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.10 | Integer32 (0..999) | RO | |
column · Integer32 (0..999) · read-only · current It indicates the maximum input average power the PD is requesting in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3LocPDRequestedPowerValueA | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.11 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the PD requested power value for the Mode A pairset in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3LocPDRequestedPowerValueB | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.12 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the PD requested power value for the Mode B pairset in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3LocPSEAllocatedPowerValue | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.13 | Integer32 (0..999) | RO | |
column · Integer32 (0..999) · read-only · current It indicates the maximum input average power the PSE expects the PD to draw in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3LocPSEAllocatedPowerValueA | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.14 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the maximum input average power levels the PSE expects the dual-signature PD to draw, in units of 0.1 W, on Alternative A, when the PSE provides power over 4-pair. | ||||
| CarubaWiredLldpXdot3LocPSEAllocatedPowerValueB | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.15 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the maximum input average power levels the PSE expects the dual-signature PD to draw, in units of 0.1 W, on Alternative B, when the PSE provides power over 4-pair. | ||||
| CarubaWiredLldpXdot3LocPSEPoweringStatus | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.16 | INTEGER | RW | |
column · INTEGER · read-write · current This field reflects the existing powering configuration of the PSE and thus indicates that the PSE is using the 'PSE allocated power value' field or is using the 'PSE allocated power value Alternative A' field and 'PSE allocated power value Alternative B' field. For a PD the contents of this attribute are undefined.
| ||||
| CarubaWiredLldpXdot3LocPowerPairsExt | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.17 | INTEGER | RW | |
column · INTEGER · read-write · current This field indicates the supported PSE Pinout Alternative. For a PD the contents of this attribute are undefined
| ||||
| CarubaWiredLldpXdot3LocPowerClassExtA | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.18 | INTEGER | RW | |
column · INTEGER · read-write · current For a dual-signature PD, it indicates the requested Class for Mode A during Physical Layer Classification. For a single-signature PD, a read-only value set to 'singlesig'. For a PSE connected to a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A. For a PSE connected to a single-signature PD, or a PSE that operates only in 2-pair mode, the value is set to 'singlesig'
| ||||
| CarubaWiredLldpXdot3LocPowerClassExtB | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.19 | INTEGER | RW | |
column · INTEGER · read-write · current For a dual-signature PD, it indicates the requested Class for Mode B during Physical Layer Classification. For a single-signature PD, a read-only value set to 'singlesig'. For a PSE connected to a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode B. For a PSE connected to a single-signature PD, or a PSE that operates only in 2-pair mode, the value is set to 'singlesig'
| ||||
| CarubaWiredLldpXdot3LocPowerClassExt | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.20 | INTEGER | RW | |
column · INTEGER · read-write · current For a single-signature PD, it indicates the requested Class during Physical Layer Classification. For a dual-signature PD, the value is set to 'dualsig'. For a PSE connected to a single-signature PD or a PSE that operates only in 2-pair mode, a readonly value that indicates the currently assigned Class. For a PSE connected to a dualsignature PD, a read-only value set to 'dualsig'.
| ||||
| CarubaWiredLldpXdot3LocPowerTypeExt | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.21 | INTEGER | RO | |
column · INTEGER · read-only · current This field indicates if the local system is a Type 3 or Type 4 PSE or PD, and in the case of a Type 3 or Type 4 PD, if it is a single-signature PD or a dual-signature PD
| ||||
| CarubaWiredLldpXdot3LocPDLoad | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.22 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate whether the load of a dual- signature PD is electrically isolated. For a single-signature PD, or a PSE, the value of this attribute is FALSE. | ||||
| CarubaWiredLldpXdot3LocPSEMaxAvailPower | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.23 | Integer32 (0..999) | RO | |
column · Integer32 (0..999) · read-only · current It indicates the local PSE maximum available power value in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3LocPSEAutoclassSupport | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.24 | TruthValue | RO | |
column · TruthValue · read-only · current It indicates whether the local PSE system supports Autoclass | ||||
| CarubaWiredLldpXdot3LocAutoclassCompleted | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.25 | TruthValue | RO | |
column · TruthValue · read-only · current It indicates whether the local PSE system has completed the Autoclass measurement | ||||
| CarubaWiredLldpLocPseTlvSentType | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.26 | INTEGER | RO | |
column · INTEGER · read-only · current This field specifies the set of TLVs that are actually sent by the PSE
| ||||
| CarubaWiredLldpLocPdTlvSentType | 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.27 | INTEGER | RO | |
column · INTEGER · read-only · current This field specifies the set of TLVs that are actually sent by the PD
| ||||
| NarubaWiredLldpXdot3RemoteData | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2 | |||
| TarubaWiredLldpXdot3RemPowerTable | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1 | NA | ||
table · not-accessible · current This table contains one row per port of power ethernet information (as a part of the LLDP 802.3bt organizational extension) on the remote system known to this agent. The MIB objects of this table are only supported for 4 pair PDs | ||||
| RarubaWiredLldpXdot3RemPowerEntry | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1 | NA | ||
row · not-accessible · current Information about a particular port component. | ||||
| CarubaWiredLldpXdot3RemPowerPortClass | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.1 | INTEGER | RO | |
column · INTEGER · read-only · current The value that identifies the port Class of the given port associated with the remote system.
| ||||
| CarubaWiredLldpXdot3RemPowerMDISupported | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.2 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate whether the MDI power is supported on the given port associated with the remote system. | ||||
| CarubaWiredLldpXdot3RemPowerMDIEnabled | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.3 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate whether the MDI power is enabled on given port associated with the remote system. | ||||
| CarubaWiredLldpXdot3RemPowerPairControlable | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.4 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate the ability to control which PSE Pinout Alternative is used for PD detection and power. | ||||
| CarubaWiredLldpXdot3RemPowerPairs | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.5 | INTEGER | RO | |
column · INTEGER · read-only · current The truth value that identifies the PSE Pinout Alternative in use for detecting and supplying power to the PD.
| ||||
| CarubaWiredLldpXdot3RemPowerClass | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.6 | INTEGER | RO | |
column · INTEGER · read-only · current The truth value that indicates the requested Class of the PD.
| ||||
| CarubaWiredLldpXdot3RemPowerType | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.7 | INTEGER | RO | |
column · INTEGER · read-only · current This field reflects the actual remote power type.
| ||||
| CarubaWiredLldpXdot3RemPowerSource | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.8 | INTEGER | RO | |
column · INTEGER · read-only · current This field reflects the remote device (PD) requested power source. This field is encoded as pseAndLocal(4) when a PD being powered both locally and by a PSE, to local(3) when the PD being powered locally only, and to pse(2) when the PD is being powered by a PSE
| ||||
| CarubaWiredLldpXdot3RemPowerPriority | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.9 | INTEGER | RW | |
column · INTEGER · read-write · current This field reflects the requested remote device power priority. When the power type is PD, this field shall be set to the power priority configured for the device. If a PD is unable to determine its power priority or it has not been configured, then this field shall be set to unknown(1). When the power type is PSE, this field shall be set to unknown(1).
| ||||
| CarubaWiredLldpXdot3RemPDRequestedPowerValue | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.10 | Integer32 (0..999) | RO | |
column · Integer32 (0..999) · read-only · current It indicates the maximum input average power the PD is requesting in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3RemPDRequestedPowerValueA | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.11 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the PD requested power value for the Mode A pairset in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3RemPDRequestedPowerValueB | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.12 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the PD requested power value for the Mode B pairset in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3RemPSEAllocatedPowerValue | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.13 | Integer32 (0..999) | RO | |
column · Integer32 (0..999) · read-only · current It indicates the PSE allocated power value received from the remote system. For a PSE, it is the PSE allocated power value that was echoed back by the remote PD, in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3RemPSEAllocatedPowerValueA | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.14 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the PSE allocated power value for the Alternative A pairset received from the remote system. For a PSE, it is the PSE allocated power value for the Alternative A pairset that was echoed back by the remote PD, in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3RemPSEAllocatedPowerValueB | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.15 | Integer32 (0..499) | RO | |
column · Integer32 (0..499) · read-only · current It indicates the PSE allocated power value for the Alternative B pairset received from the remote system. For a PSE, it is the PSE allocated power value for the Alternative A pairset that was echoed back by the remote PD, in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3RemPDPoweredStatus | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.16 | INTEGER | RW | |
column · INTEGER · read-write · current This field indicates the existing powered configuration of the PD and thus indicate that the PD is using the 'PD requested power value' field or is using the 'PD requested power value Mode A' field and the 'PD requested power value Mode B' field. For a PSE the contents of this attribute are undefined.
| ||||
| CarubaWiredLldpXdot3RemPowerClassExtA | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.17 | INTEGER | RW | |
column · INTEGER · read-write · current For a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A by the remote 4-pair PSE. For a single-signature PD, or a dual-signature PD connected to a 2-pair only PSE, a read-only value set to 'singlesig' by the remote PSE. For a PSE connected to a dualsignature PD, a read-only value that indicates the requested Class for Mode A during Physical Layer classification by the remote PD. For a PSE connected to a single-signature PD, a read-only value set to 'singlesig' by the remote PD
| ||||
| CarubaWiredLldpXdot3RemPowerClassExtB | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.18 | INTEGER | RW | |
column · INTEGER · read-write · current For a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A by the remote 4-pair PSE. For a single-signature PD, or a dual-signature PD connected to a 2-pair only PSE, a read-only value set to 'singlesig' by the remote PSE. For a PSE connected to a dualsignature PD, a read-only value that indicates the requested Class for Mode B during Physical Layer classification by the remote PD. For a PSE connected to a single-signature PD, a read-only value set to 'singlesig' by the remote PD.
| ||||
| CarubaWiredLldpXdot3RemPowerClassExt | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.19 | INTEGER | RW | |
column · INTEGER · read-write · current For a single-signature PD or a dual-signature PD connected to a 2-pair only PSE, a read-only value that indicates the currently assigned Class by the remote PSE. For a dual- signature PD connected to a 4-pair capable PSE, a read-only value set to 'dualsig' by the remote PSE. For a PSE connected to a single-signature PD, a read-only value that indicates the requested Class during Physical Layer classification by the remote PD. For a PSE connected to a dual-signature PD, a readonly value set to 'dualsig' by the remote PD.
| ||||
| CarubaWiredLldpXdot3RemPowerTypeExt | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.20 | INTEGER | RO | |
column · INTEGER · read-only · current This field indicates if the remote system is a Type 3 or Type 4 PSE or PD, and in the case of a Type 3 or Type 4 PD, if it is a single-signature PD or dual-signature PD
| ||||
| CarubaWiredLldpXdot3RemPDLoad | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.21 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate whether the load of the remote dual-signature PD is electrically isolated. For a PD this attribute is set to FALSE | ||||
| CarubaWiredLldpXdot3RemPD4PID | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.22 | TruthValue | RO | |
column · TruthValue · read-only · current The truth value used to indicate whether the remote PD system supports powering of both PD Modes | ||||
| CarubaWiredLldpXdot3RemPSEMaxAvailPower | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.23 | Integer32 (0..999) | RO | |
column · Integer32 (0..999) · read-only · current It indicates the remote PSE maximum available power value in units of 0.1 W. | ||||
| CarubaWiredLldpXdot3RemAutoclassRequest | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.24 | TruthValue | RO | |
column · TruthValue · read-only · current It indicates whether the remote PD system is requesting an Autoclass measurement | ||||
| CarubaWiredLldpXdot3RemPowerDownRequest | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.25 | Integer32 | RO | |
column · Integer32 · read-only · current It indicates that the remote PD system is requesting a power down when the value is 0x1D | ||||
| CarubaWiredLldpXdot3RemPowerDownTime | 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.26 | Integer32 | RO | |
column · Integer32 · read-only · current It indicates the number of seconds the remote PD requests to stay powered off. A value of zero indicates an indefinite amount of time. | ||||
| NarubaWiredLldpConformance | 1.3.6.1.4.1.47196.4.1.1.3.9.2 | |||
| NarubaWiredLldpCompliances | 1.3.6.1.4.1.47196.4.1.1.3.9.2.1 | |||
| MarubaWiredLldpXdot3Compliance | 1.3.6.1.4.1.47196.4.1.1.3.9.2.1.1 | |||
compliance · current The compliance statement for LLDP implementation. | ||||
| MarubaWiredLldpScalarCompliance | 1.3.6.1.4.1.47196.4.1.1.3.9.2.1.2 | |||
| NarubaWiredLldpGroups | 1.3.6.1.4.1.47196.4.1.1.3.9.2.2 | |||
| GarubaWiredLldpXdot3LocSysGroup | 1.3.6.1.4.1.47196.4.1.1.3.9.2.2.1 | |||
group · current The collection of objects which are used to represent LLDP 802.3 organizational extension for POEP Local Device Information. This group is mandatory for agents which implement the LLDP 802.3 organizational extension for POEP.
| ||||
| GarubaWiredLldpXdot3RemSysGroup | 1.3.6.1.4.1.47196.4.1.1.3.9.2.2.2 | |||
group · current The collection of objects which are used to represent LLDP 802.3 organizational extension for POEP Remote Device Information. This group is mandatory for agents which implement the LLDP 802.3 organizational extension for POEP.
| ||||
| GarubaWiredLldpScalarGroup | 1.3.6.1.4.1.47196.4.1.1.3.9.2.2.3 | |||
group · current These objects are used for managing/monitoring LLDP global parameters.
| ||||
| NarubaWiredLldpScalarConfig | 1.3.6.1.4.1.47196.4.1.1.3.9.3 | |||
| SarubaWiredLldpMgmtAddrVlanId | 1.3.6.1.4.1.47196.4.1.1.3.9.3.1 | Integer32 (0..4094) | RW | |
scalar · Integer32 (0..4094) · read-write · current Defines the LLDP management VLAN whose IPv4/IPv6 address will be advertised. Value '0' indicates that LLDP management VLAN is not configured. | ||||