ARRIS-C3-FPD-MIB
Arris Interactive LLCThis MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3
snmptranslate -m ARRIS-C3-FPD-MIB -Tpsnmpwalk -v2c -c <community> -m ARRIS-C3-FPD-MIB <host> 1.3.6.1.4.1.4115.1.4.3.3Imports
| ARRIS-MIB | cmtsC3 |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IcmtsC3FPDMIB | 1.3.6.1.4.1.4115.1.4.3.3 | ||||||||||||
identity This MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3 | |||||||||||||
| NdcxFPDObjects | 1.3.6.1.4.1.4115.1.4.3.3.1 | ||||||||||||
| TdcxFPDMsgTable | 1.3.6.1.4.1.4115.1.4.3.3.1.1 | NA | |||||||||||
table · not-accessible · current Table of Front Panel LCD Messages. | |||||||||||||
| RdcxFPDMsgEntry | 1.3.6.1.4.1.4115.1.4.3.3.1.1.1 | NA | |||||||||||
| CdcxFPDMsgIndex | 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.1 | Unsigned32 | NA | ||||||||||
column · Unsigned32 · not-accessible · current Index used to order the FPD Messages. | |||||||||||||
| CdcxFPDMsgString | 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.2 | OCTET STRING (SIZE (0..12)) | RW | ||||||||||
column · OCTET STRING (SIZE (0..12)) · read-write · current Specifies a string that can be displayed on the front panel. | |||||||||||||
| NdcxFPDControlGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.2 | ||||||||||||
| SdcxFPDAttachedStatus | 1.3.6.1.4.1.4115.1.4.3.3.1.2.1 | INTEGER | RO | attached(1) | |||||||||
scalar · INTEGER · read-only · current Displays if the front panel display is attached to the Cmts or not.
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDPowerStatus1 | 1.3.6.1.4.1.4115.1.4.3.3.1.2.2 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current Specifies if the primary power supply is working. This is the rightmost power supply. The following values are possible: on(1) and off(2)
| |||||||||||||
| SdcxFPDPowerStatus2 | 1.3.6.1.4.1.4115.1.4.3.3.1.2.3 | INTEGER | RO | on(1) | |||||||||
scalar · INTEGER · read-only · current Specifies if the secondary power supply is working. This is the leftmost power supply(nearest the fan tray). The following values are possible: on(1) and off(2)
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDTemp1Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.4 | Integer32 | RO | 3800 | |||||||||
scalar · Integer32 · read-only · current Specifies the temperature reading for the sensor on the CPU card closest to the CPU. Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDTemp2Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.5 | Integer32 | RO | 3400 | |||||||||
scalar · Integer32 · read-only · current Specifies the temperature reading for the sensor on the CPU card, on the right hand side. Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDTemp3Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.6 | Integer32 | RO | 3800 | |||||||||
scalar · Integer32 · read-only · current Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX4 and RX5. Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDTemp4Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.7 | Integer32 | RO | 4000 | |||||||||
scalar · Integer32 · read-only · current Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX2 and RX3. Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDFan1Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.8 | INTEGER | RO | rotating(1) | |||||||||
scalar · INTEGER · read-only · current Specifies the fan status for the fan nearest the front of the box. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDFan2Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.9 | INTEGER | RO | rotating(1) | |||||||||
scalar · INTEGER · read-only · current Specifies the fan status for the fan 2nd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDFan3Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.10 | INTEGER | RO | rotating(1) | |||||||||
scalar · INTEGER · read-only · current Specifies the fan status for the fan 3rd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDFan4Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.11 | INTEGER | RO | rotating(1) | |||||||||
scalar · INTEGER · read-only · current Specifies the fan status for the fan 4th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDFan5Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.12 | INTEGER | RO | rotating(1) | |||||||||
scalar · INTEGER · read-only · current Specifies the fan status for the fan 5th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDFan6Status | 1.3.6.1.4.1.4115.1.4.3.3.1.2.13 | INTEGER | RO | rotating(1) | |||||||||
scalar · INTEGER · read-only · current Specifies the fan status for the fan nearest the back of the box The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Example values from LibreNMS test devices
| |||||||||||||
| SdcxFPDFanUpperLimit | 1.3.6.1.4.1.4115.1.4.3.3.1.2.14 | Integer32 (0..255) | RW | ||||||||||
scalar · Integer32 (0..255) · read-write · current Specifies the upper fan limit(Upper threshold of expected current draw) | |||||||||||||
| SdcxFPDFanLowerLimit | 1.3.6.1.4.1.4115.1.4.3.3.1.2.15 | Integer32 (0..255) | RW | ||||||||||
scalar · Integer32 (0..255) · read-write · current Specifies the lower fan limit(Lower threshold of expected current draw) | |||||||||||||
| SdcxFPDLCDContrast | 1.3.6.1.4.1.4115.1.4.3.3.1.2.16 | Integer32 (0..65535) | RW | ||||||||||
scalar · Integer32 (0..65535) · read-write · current Specifies the contrast level for the LCD | |||||||||||||
| SdcxFPDLedSetStatus | 1.3.6.1.4.1.4115.1.4.3.3.1.2.17 | Integer32 (0..65535) | RW | ||||||||||
scalar · Integer32 (0..65535) · read-write · current Used to turn on or off a Led on the front panel | |||||||||||||
| SdcxFPDHwRevision | 1.3.6.1.4.1.4115.1.4.3.3.1.2.18 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current Specifies the front panel h/w revision | |||||||||||||
| SdcxFPDSwRevision | 1.3.6.1.4.1.4115.1.4.3.3.1.2.19 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current Specifies the front panel s/w revision | |||||||||||||
| NdcxFPDTrapGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.3 | ||||||||||||
| !dcxFPDAttached | 1.3.6.1.4.1.4115.1.4.3.3.1.3.1 | ||||||||||||
notification · current Front Panel Display has been attached. | |||||||||||||
| !dcxFPDDetached | 1.3.6.1.4.1.4115.1.4.3.3.1.3.2 | ||||||||||||
notification · current Front Panel Display has been detached. | |||||||||||||
| !dcxFPDFan1Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.3 | ||||||||||||
notification · current Fan nearest the front of the box failed | |||||||||||||
| !dcxFPDFan1FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.4 | ||||||||||||
notification · current Fan nearest the front of the box is working | |||||||||||||
| !dcxFPDFan2Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.5 | ||||||||||||
notification · current Fan 2nd from the front failed | |||||||||||||
| !dcxFPDFan2FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.6 | ||||||||||||
notification · current Fan 2nd from the front is working | |||||||||||||
| !dcxFPDFan3Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.7 | ||||||||||||
notification · current Fan 3rd from the front failed | |||||||||||||
| !dcxFPDFan3FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.8 | ||||||||||||
notification · current Fan 3rd from the front is working | |||||||||||||
| !dcxFPDFan4Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.9 | ||||||||||||
notification · current Fan 4th from the front failed | |||||||||||||
| !dcxFPDFan4FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.10 | ||||||||||||
notification · current Fan 4th from the front is working | |||||||||||||
| !dcxFPDFan5Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.11 | ||||||||||||
notification · current Fan 5th from the front failed | |||||||||||||
| !dcxFPDFan5FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.12 | ||||||||||||
notification · current Fan 5th from the front is working | |||||||||||||
| !dcxFPDFan6Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.13 | ||||||||||||
notification · current Fan nearest the back of the box failed | |||||||||||||
| !dcxFPDFan6FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.14 | ||||||||||||
notification · current Fan nearest the back of the box is working | |||||||||||||
| !dcxFPDPwr1Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.15 | ||||||||||||
notification · current Rightmost power supply failed | |||||||||||||
| !dcxFPDPwr1FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.16 | ||||||||||||
notification · current Rightmost power supply is working | |||||||||||||
| !dcxFPDPwr2Fail | 1.3.6.1.4.1.4115.1.4.3.3.1.3.17 | ||||||||||||
notification · current Leftmost power supply failed | |||||||||||||
| !dcxFPDPwr2FailClr | 1.3.6.1.4.1.4115.1.4.3.3.1.3.18 | ||||||||||||
notification · current Leftmost power supply is working | |||||||||||||
| !dcxFPDTempOkay | 1.3.6.1.4.1.4115.1.4.3.3.1.3.19 | ||||||||||||
notification · current System temperature is OK | |||||||||||||
| !dcxFPDTempBad | 1.3.6.1.4.1.4115.1.4.3.3.1.3.20 | ||||||||||||
notification · current System temperature is too hot! | |||||||||||||
| !dcxFPDTempCritical | 1.3.6.1.4.1.4115.1.4.3.3.1.3.21 | ||||||||||||
notification · current System temperature is critical!!!, CMTS will shut itself down!!!! | |||||||||||||
| NdcxFPDConformance | 1.3.6.1.4.1.4115.1.4.3.3.1.4 | ||||||||||||
| NdcxFPDCompliances | 1.3.6.1.4.1.4115.1.4.3.3.1.4.1 | ||||||||||||
| MdcxFPDCompliance | 1.3.6.1.4.1.4115.1.4.3.3.1.4.1.1 | ||||||||||||
compliance · current The compliance statement for devices that implement Arris C3 compliant FPD features
| |||||||||||||
| NdcxFPDGroups | 1.3.6.1.4.1.4115.1.4.3.3.1.4.2 | ||||||||||||
| GdcxFPDMsgGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.1 | ||||||||||||
| GdcxFPDControlConfGroup | 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.2 | ||||||||||||
group · current Arris C3 FPD Control group
| |||||||||||||
Traps / Notifications
- dcxFPDAttached
1.3.6.1.4.1.4115.1.4.3.3.1.3.1 - dcxFPDDetached
1.3.6.1.4.1.4115.1.4.3.3.1.3.2 - dcxFPDFan1Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.3 - dcxFPDFan1FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.4 - dcxFPDFan2Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.5 - dcxFPDFan2FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.6 - dcxFPDFan3Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.7 - dcxFPDFan3FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.8 - dcxFPDFan4Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.9 - dcxFPDFan4FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.10 - dcxFPDFan5Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.11 - dcxFPDFan5FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.12 - dcxFPDFan6Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.13 - dcxFPDFan6FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.14 - dcxFPDPwr1Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.15 - dcxFPDPwr1FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.16 - dcxFPDPwr2Fail
1.3.6.1.4.1.4115.1.4.3.3.1.3.17 - dcxFPDPwr2FailClr
1.3.6.1.4.1.4115.1.4.3.3.1.3.18 - dcxFPDTempBad
1.3.6.1.4.1.4115.1.4.3.3.1.3.20 - dcxFPDTempCritical
1.3.6.1.4.1.4115.1.4.3.3.1.3.21 - dcxFPDTempOkay
1.3.6.1.4.1.4115.1.4.3.3.1.3.19