ADIC-INTELLIGENT-STORAGE-MIB
Quantum Corporation (formerly 'Advanced Digital Information Corporation')This MIB provides Tape Library product information.
snmptranslate -m ADIC-INTELLIGENT-STORAGE-MIB -Tpsnmpwalk -v2c -c <community> -m ADIC-INTELLIGENT-STORAGE-MIB <host> 1.3.6.1.4.1.3764.1.1Imports
| RFC1155-SMI | Counter32 |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nquantum | 1.3.6.1.4.1.3764 | ||||||||||||||||||||
| Nstorage | 1.3.6.1.4.1.3764.1 | ||||||||||||||||||||
| Iintelligent | 1.3.6.1.4.1.3764.1.1 | ||||||||||||||||||||
identity This MIB provides Tape Library product information. | |||||||||||||||||||||
| !startupSequenceComplete | 1.3.6.1.4.1.3764.1.1.0.500 | ||||||||||||||||||||
notification The physical library completed a library initialization sequence: componentId - identifies reporting controller trapSummaryText - identifies completion of library initialization sequence
| |||||||||||||||||||||
| !shutdownSequenceInitiated | 1.3.6.1.4.1.3764.1.1.0.501 | ||||||||||||||||||||
notification The physical library initiated a shutdown operation: componentId - identifies reporting controller trapSummaryText - identifies library shutdown operation
| |||||||||||||||||||||
| !componentAdded | 1.3.6.1.4.1.3764.1.1.0.502 | ||||||||||||||||||||
notification The component indicated by the value of componentId has been added to the library.
| |||||||||||||||||||||
| !componentRemoved | 1.3.6.1.4.1.3764.1.1.0.503 | ||||||||||||||||||||
notification The component indicated by the value of componentId has been removed from the library.
| |||||||||||||||||||||
| !productLibraryClassChange | 1.3.6.1.4.1.3764.1.1.0.504 | ||||||||||||||||||||
notification The product library class has changed. This occurs when connectivity hardware is added or removed. The payload contains the productLibraryClass before and after the change. | |||||||||||||||||||||
| NproductAgentInfo | 1.3.6.1.4.1.3764.1.1.10 | ||||||||||||||||||||
| SproductMibVersion | 1.3.6.1.4.1.3764.1.1.10.1 | AdicMibVersion | RO | mandatory | |||||||||||||||||
scalar · AdicMibVersion · read-only · mandatory MIB version identifier. | |||||||||||||||||||||
| SproductSnmpAgentVersion | 1.3.6.1.4.1.3764.1.1.10.2 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory SNMP agent version identifier. | |||||||||||||||||||||
| SproductName | 1.3.6.1.4.1.3764.1.1.10.3 | DisplayString | RO | mandatory | Scalar i6000 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory Name of ADIC branded product. Uniquely identifies the product, independent of OEM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| SproductDisplayName | 1.3.6.1.4.1.3764.1.1.10.4 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Name of this agent for display purposes. May be customized for OEM. | |||||||||||||||||||||
| SproductDescription | 1.3.6.1.4.1.3764.1.1.10.5 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory A short description of this SNMP agent. | |||||||||||||||||||||
| SproductVendor | 1.3.6.1.4.1.3764.1.1.10.6 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory Name of the product vendor or OEM. | |||||||||||||||||||||
| SproductVersion | 1.3.6.1.4.1.3764.1.1.10.7 | DisplayString | RO | mandatory | 800Q.GS25700 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory String Format: MNNO.TVBBBPP
Examples
1. 091a.TR054
Version 0.91, build 54 of the RCS test code for ADIC
2. 100A.GM052
Version 1.00, build 52 of the MCB GA candidate code for ADIC
M Major version number
NN Minor version number
O OEM (Uppercase when release candidate, otherwise lowercase)
A/a - ADIC
Others - Reserved)
T Target
G - GA Candidate Release (labeled build that is a release candidate)
T - Test build (labeled build used for formal testing)
D - Dev build (labeled build used for unit testing)
(lower case) - specifies developer of a local build
V Variant
S - System
R - RCS
M - MCB
BBB Build number (3 digit sequential number specifying exact build)
PP Patch Number (Optional alphanumeric characters denoting patch
level of this build if necessary)Example values from LibreNMS test devices
| |||||||||||||||||||||
| SproductDisplayVersion | 1.3.6.1.4.1.3764.1.1.10.8 | DisplayString | RO | mandatory | |||||||||||||||||
scalar · DisplayString · read-only · mandatory The version identifier according to the vendor or OEM. | |||||||||||||||||||||
| SproductLibraryClass | 1.3.6.1.4.1.3764.1.1.10.9 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Basic library includes minimal connectivity hardware. Intelligent library includes SAN appliances and value-added features.
| |||||||||||||||||||||
| SproductSerialNumber | 1.3.6.1.4.1.3764.1.1.10.10 | DisplayString | RO | mandatory | 263102381 | ||||||||||||||||
scalar · DisplayString · read-only · mandatory The serial number of the physical library. Example values from LibreNMS test devices
| |||||||||||||||||||||
| NglobalData | 1.3.6.1.4.1.3764.1.1.20 | ||||||||||||||||||||
| SagentGlobalStatus | 1.3.6.1.4.1.3764.1.1.20.1 | AdicAgentStatus | RO | mandatory | |||||||||||||||||
scalar · AdicAgentStatus · read-only · mandatory Current overall status of the agent. | |||||||||||||||||||||
| SagentLastGlobalStatus | 1.3.6.1.4.1.3764.1.1.20.2 | AdicAgentStatus | RO | mandatory | |||||||||||||||||
scalar · AdicAgentStatus · read-only · mandatory The status before the current status which induced an initiative to issue a global status change trap. | |||||||||||||||||||||
| SagentTimeStamp | 1.3.6.1.4.1.3764.1.1.20.3 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory The last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70. | |||||||||||||||||||||
| SagentGetTimeOut | 1.3.6.1.4.1.3764.1.1.20.4 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Suggested time out in milliseconds for how long an SNMP management application should wait while attempting to poll the SNMP agent. | |||||||||||||||||||||
| SagentModifiers | 1.3.6.1.4.1.3764.1.1.20.5 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Agent functional modifiers, when set the modifier is active. ----------------------------------------------------- Bit 3 => Agent in debug mode. ----------------------------------------------------- All other bits are product specific. | |||||||||||||||||||||
| SagentRefreshRate | 1.3.6.1.4.1.3764.1.1.20.6 | INTEGER | RO | mandatory | |||||||||||||||||
scalar · INTEGER · read-only · mandatory Rate in seconds at which the agent cached data is being updated. | |||||||||||||||||||||
| Ncomponents | 1.3.6.1.4.1.3764.1.1.30 | ||||||||||||||||||||
| TcomponentTable | 1.3.6.1.4.1.3764.1.1.30.10 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory General information about the system's components, including the unique identifiers. The structure this table is based on the Fibre Alliance MIB connUnitEntry. | |||||||||||||||||||||
| RcomponentEntry | 1.3.6.1.4.1.3764.1.1.30.10.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory A component entry containing objects for a particular component.
| |||||||||||||||||||||
| CcomponentId | 1.3.6.1.4.1.3764.1.1.30.10.1.1 | AdicGlobalId | RO | mandatory | |||||||||||||||||
column · AdicGlobalId · read-only · mandatory The unique identification for this component among those within this proxy domain. | |||||||||||||||||||||
| CcomponentType | 1.3.6.1.4.1.3764.1.1.30.10.1.2 | AdicComponentType | RO | mandatory | |||||||||||||||||
column · AdicComponentType · read-only · mandatory The type of this component. | |||||||||||||||||||||
| CcomponentDisplayName | 1.3.6.1.4.1.3764.1.1.30.10.1.3 | DisplayString (SIZE (0..79)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..79)) · read-only · mandatory Name of this component for display purposes. Different OEMs may have different display names for the same ADIC product. | |||||||||||||||||||||
| CcomponentInfo | 1.3.6.1.4.1.3764.1.1.30.10.1.4 | DisplayString | RW | mandatory | |||||||||||||||||
column · DisplayString · read-write · mandatory A display string containing information about this component. | |||||||||||||||||||||
| CcomponentLocation | 1.3.6.1.4.1.3764.1.1.30.10.1.5 | DisplayString (SIZE (0..79)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..79)) · read-only · mandatory Location information for this component. | |||||||||||||||||||||
| CcomponentVendor | 1.3.6.1.4.1.3764.1.1.30.10.1.6 | DisplayString (SIZE (0..79)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..79)) · read-only · mandatory Name vendor of this component. | |||||||||||||||||||||
| CcomponentSn | 1.3.6.1.4.1.3764.1.1.30.10.1.7 | DisplayString (SIZE (0..79)) | RO | mandatory | |||||||||||||||||
column · DisplayString (SIZE (0..79)) · read-only · mandatory The serial number for this component. | |||||||||||||||||||||
| CcomponentStatus | 1.3.6.1.4.1.3764.1.1.30.10.1.8 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory Overall status of the component.
| |||||||||||||||||||||
| CcomponentControl | 1.3.6.1.4.1.3764.1.1.30.10.1.9 | INTEGER | RW | mandatory | |||||||||||||||||
column · INTEGER · read-write · mandatory This object is used to control the addressed
connUnit.
NOTE: 'Cold Start' and 'Warm Start'
are as defined in MIB II and are not meant
to be a factory reset.
resetColdStart:
the addressed unit performs
a 'Cold Start' reset.
resetWarmStart:
the addressed unit performs
a 'Warm Start' reset.
offline:
the addressed unit puts itself into
an implementation dependant 'offline' state.
online:
the addressed unit puts itself into an
implementation dependant 'online' state.
| |||||||||||||||||||||
| CcomponentREDId | 1.3.6.1.4.1.3764.1.1.30.10.1.10 | AdicREDIdentifier | RO | mandatory | |||||||||||||||||
column · AdicREDIdentifier · read-only · mandatory Runtime Error Detection identifier for this component. | |||||||||||||||||||||
| CcomponentFirmwareVersion | 1.3.6.1.4.1.3764.1.1.30.10.1.11 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory Firmware version (or level) for this component. | |||||||||||||||||||||
| CcomponentGeoAddrAisle | 1.3.6.1.4.1.3764.1.1.30.10.1.12 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The aisle number where this component is located. A negative value indicates that an aisle number is not applicable to this component. | |||||||||||||||||||||
| CcomponentGeoAddrFrame | 1.3.6.1.4.1.3764.1.1.30.10.1.13 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The frame number where this component is located. A negative value indicates that a frame number is not applicable to this component. | |||||||||||||||||||||
| CcomponentGeoAddrRack | 1.3.6.1.4.1.3764.1.1.30.10.1.14 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The rack number where this component is located. A negative value indicates that a rack number is not applicable to this component. | |||||||||||||||||||||
| CcomponentGeoAddrChassis | 1.3.6.1.4.1.3764.1.1.30.10.1.15 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The chassis number where this component is located. A negative value indicates that a chassis number is not applicable to this component. | |||||||||||||||||||||
| CcomponentGeoAddrBlade | 1.3.6.1.4.1.3764.1.1.30.10.1.16 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The blade number within the network chasis where this component is located. A negative value indicates that a blade number is not applicable to this component. | |||||||||||||||||||||
| CcomponentIpAddress | 1.3.6.1.4.1.3764.1.1.30.10.1.17 | IpAddress | RO | mandatory | |||||||||||||||||
column · IpAddress · read-only · mandatory IP address of this component. If the component has no IP address, this object returns 0.0.0.0. The address may refer to an internal network not accessible to an external management application. | |||||||||||||||||||||
| Nsoftware | 1.3.6.1.4.1.3764.1.1.100 | ||||||||||||||||||||
| Nhardware | 1.3.6.1.4.1.3764.1.1.200 | ||||||||||||||||||||
| NpowerAndCooling | 1.3.6.1.4.1.3764.1.1.200.200 | ||||||||||||||||||||
| TpowerSupplyTable | 1.3.6.1.4.1.3764.1.1.200.200.10 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory This table provides power supply information. | |||||||||||||||||||||
| RpowerSupplyEntry | 1.3.6.1.4.1.3764.1.1.200.200.10.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains the information for a specific power supply.
| |||||||||||||||||||||
| CpowerSupplyIndex | 1.3.6.1.4.1.3764.1.1.200.200.10.1.1 | INTEGER (0..1024) | RO | mandatory | 1 | ||||||||||||||||
column · INTEGER (0..1024) · read-only · mandatory Index of this power supply within the component specified by componentId. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyName | 1.3.6.1.4.1.3764.1.1.200.200.10.1.2 | DisplayString | RO | mandatory | Lib PS Mfg Unknown (Fr:1 IEX4 HW req'd) | ||||||||||||||||
column · DisplayString · read-only · mandatory Display name of this power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyWattage | 1.3.6.1.4.1.3764.1.1.200.200.10.1.3 | INTEGER | RO | mandatory | 2000 | ||||||||||||||||
column · INTEGER · read-only · mandatory Maximum power output of this power supply. Units are in Watts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyType | 1.3.6.1.4.1.3764.1.1.200.200.10.1.4 | AdicVoltageType | RO | mandatory | 2 | ||||||||||||||||
column · AdicVoltageType · read-only · mandatory Power supply type, AC or DC. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyREDId | 1.3.6.1.4.1.3764.1.1.200.200.10.1.5 | AdicREDIdentifier | RO | mandatory | 83951873 | ||||||||||||||||
column · AdicREDIdentifier · read-only · mandatory Runtime Error Detection identifier for this power supply. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyRatedVoltage | 1.3.6.1.4.1.3764.1.1.200.200.10.1.6 | INTEGER | RO | mandatory | 48000 | ||||||||||||||||
column · INTEGER · read-only · mandatory Rated output voltage of this power supply. Units are in in millivolts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyLocation | 1.3.6.1.4.1.3764.1.1.200.200.10.1.7 | DisplayString | RO | mandatory | Library PS #1 [Fr:1, PS:1] | ||||||||||||||||
column · DisplayString · read-only · mandatory Power supply location in the library. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyStatus | 1.3.6.1.4.1.3764.1.1.200.200.10.1.8 | AdicPowerSupplyStatus | RO | mandatory | 3 | ||||||||||||||||
column · AdicPowerSupplyStatus · read-only · mandatory Power Supply operational status. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CpowerSupplyPowerConsumption | 1.3.6.1.4.1.3764.1.1.200.200.10.1.9 | INTEGER | RO | mandatory | 0 | ||||||||||||||||
column · INTEGER · read-only · mandatory Power consumption of this power supply. Units are in watts. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TvoltageSensorTable | 1.3.6.1.4.1.3764.1.1.200.200.20 | NA | optional | ||||||||||||||||||
table · not-accessible · optional This table provides voltage sensor information. | |||||||||||||||||||||
| RvoltageSensorEntry | 1.3.6.1.4.1.3764.1.1.200.200.20.1 | NA | optional | ||||||||||||||||||
row · not-accessible · optional Each entry contains the information for a specific voltage sensor. | |||||||||||||||||||||
| CvoltageSensorIndex | 1.3.6.1.4.1.3764.1.1.200.200.20.1.1 | INTEGER (0..1024) | RO | optional | |||||||||||||||||
column · INTEGER (0..1024) · read-only · optional Index of this voltage sensor within the component specified by componentId. | |||||||||||||||||||||
| CvoltageSensorName | 1.3.6.1.4.1.3764.1.1.200.200.20.1.2 | DisplayString | RO | optional | |||||||||||||||||
column · DisplayString · read-only · optional Display name of this voltage sensor. | |||||||||||||||||||||
| CvoltageSensorStatus | 1.3.6.1.4.1.3764.1.1.200.200.20.1.3 | AdicSensorStatus | RO | optional | |||||||||||||||||
column · AdicSensorStatus · read-only · optional Voltage sensor state; - nominal, warning or alarm. | |||||||||||||||||||||
| CvoltageSensorMillivolts | 1.3.6.1.4.1.3764.1.1.200.200.20.1.4 | INTEGER | RO | optional | |||||||||||||||||
column · INTEGER · read-only · optional Voltage sensor voltage. units are in millivolts. | |||||||||||||||||||||
| CvoltageSensorType | 1.3.6.1.4.1.3764.1.1.200.200.20.1.5 | AdicVoltageType | RO | optional | |||||||||||||||||
column · AdicVoltageType · read-only · optional Voltage sensor type; - DC or AC. | |||||||||||||||||||||
| CvoltageSensorNominalLo | 1.3.6.1.4.1.3764.1.1.200.200.20.1.6 | INTEGER | RO | optional | |||||||||||||||||
column · INTEGER · read-only · optional Lower voltage limit of the nominal state for this voltage sensor. Units are in millivolts. | |||||||||||||||||||||
| CvoltageSensorNominalHi | 1.3.6.1.4.1.3764.1.1.200.200.20.1.7 | INTEGER | RO | optional | |||||||||||||||||
column · INTEGER · read-only · optional Upper voltage limit of the nominal state for this voltage sensor. Units are in millivolts. | |||||||||||||||||||||
| CvoltageSensorWarningLo | 1.3.6.1.4.1.3764.1.1.200.200.20.1.8 | INTEGER | RO | optional | |||||||||||||||||
column · INTEGER · read-only · optional Lower voltage limit of the warning state for this voltage sensor. Units are in millivolts. If the voltage falls below this limit, the sensor enters the alarm state. | |||||||||||||||||||||
| CvoltageSensorWarningHi | 1.3.6.1.4.1.3764.1.1.200.200.20.1.9 | INTEGER | RO | optional | |||||||||||||||||
column · INTEGER · read-only · optional Upper voltage limit of the warning state
for this voltage sensor. Units are in millivolts.
If the voltage rises above this limit, the
sensor enters the alarm state. | |||||||||||||||||||||
| CvoltageSensorLocation | 1.3.6.1.4.1.3764.1.1.200.200.20.1.10 | DisplayString | RO | optional | |||||||||||||||||
column · DisplayString · read-only · optional Physical location of the voltage sensor. | |||||||||||||||||||||
| CvoltageSensorREDId | 1.3.6.1.4.1.3764.1.1.200.200.20.1.11 | AdicREDIdentifier | RO | optional | |||||||||||||||||
column · AdicREDIdentifier · read-only · optional Runtime Error Detection identifier for this voltage sensor. | |||||||||||||||||||||
| TtemperatureSensorTable | 1.3.6.1.4.1.3764.1.1.200.200.30 | NA | optional | ||||||||||||||||||
table · not-accessible · optional This table provides temperature sensor information | |||||||||||||||||||||
| RtemperatureSensorEntry | 1.3.6.1.4.1.3764.1.1.200.200.30.1 | NA | optional | ||||||||||||||||||
row · not-accessible · optional Each entry contains the information for a specific sensor of a specifc component id. | |||||||||||||||||||||
| CtemperatureSensorIndex | 1.3.6.1.4.1.3764.1.1.200.200.30.1.1 | INTEGER (0..1024) | RO | optional | 1 | ||||||||||||||||
column · INTEGER (0..1024) · read-only · optional Index of this temperature sensor within the component specified by componentId. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorName | 1.3.6.1.4.1.3764.1.1.200.200.30.1.2 | DisplayString | RO | optional | RCU2 | ||||||||||||||||
column · DisplayString · read-only · optional Display name of this temperature sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorStatus | 1.3.6.1.4.1.3764.1.1.200.200.30.1.3 | AdicSensorStatus | RO | optional | 1 | ||||||||||||||||
column · AdicSensorStatus · read-only · optional Current state of the temperature sensor; - Nominal, warning or alarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorDegreesCelsius | 1.3.6.1.4.1.3764.1.1.200.200.30.1.4 | INTEGER | RO | optional | 21 | ||||||||||||||||
column · INTEGER · read-only · optional The temperature in degrees Celsius for this temperature sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorNominalLo | 1.3.6.1.4.1.3764.1.1.200.200.30.1.5 | INTEGER | RO | optional | 15 | ||||||||||||||||
column · INTEGER · read-only · optional Lower temperature limit of the nominal state for this temperature sensor. Units are in degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorNominalHi | 1.3.6.1.4.1.3764.1.1.200.200.30.1.6 | INTEGER | RO | optional | 50 | ||||||||||||||||
column · INTEGER · read-only · optional Upper temperature limit of the nominal state for this temperature sensor. Units are in degrees Celsius. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorWarningLo | 1.3.6.1.4.1.3764.1.1.200.200.30.1.7 | INTEGER | RO | optional | 10 | ||||||||||||||||
column · INTEGER · read-only · optional Lower temperature limit of the warning state for this temperature sensor. Units are in degrees Celsius. If the temperature falls below this limit, the sensor enters the alarm state. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorWarningHi | 1.3.6.1.4.1.3764.1.1.200.200.30.1.8 | INTEGER | RO | optional | 60 | ||||||||||||||||
column · INTEGER · read-only · optional Upper temperature limit of the warning state
for this temperature sensor. Units are in degrees Celsius.
If the temperature rises above this
limit, the sensor enters the alarm state.Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorLocation | 1.3.6.1.4.1.3764.1.1.200.200.30.1.9 | DisplayString | RO | optional | Library Temperature Sensor #1 | ||||||||||||||||
column · DisplayString · read-only · optional Physical location of this temperature sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CtemperatureSensorREDId | 1.3.6.1.4.1.3764.1.1.200.200.30.1.10 | AdicREDIdentifier | RO | optional | 83951873 | ||||||||||||||||
column · AdicREDIdentifier · read-only · optional Runtime Error Detection identifier for this temperature sensor. Example values from LibreNMS test devices
| |||||||||||||||||||||
| TcoolingFanTable | 1.3.6.1.4.1.3764.1.1.200.200.40 | NA | optional | ||||||||||||||||||
table · not-accessible · optional This table provides library (not drive) cooling fan information. | |||||||||||||||||||||
| RcoolingFanEntry | 1.3.6.1.4.1.3764.1.1.200.200.40.1 | NA | optional | ||||||||||||||||||
row · not-accessible · optional Each entry contains the information for a specific cooling fan.
| |||||||||||||||||||||
| CcoolingFanIndex | 1.3.6.1.4.1.3764.1.1.200.200.40.1.1 | INTEGER (0..1024) | RO | optional | 1 | ||||||||||||||||
column · INTEGER (0..1024) · read-only · optional Index of this cooling fan within the component specified by componentId. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanName | 1.3.6.1.4.1.3764.1.1.200.200.40.1.2 | DisplayString | RO | optional | CMB2 Cooling fan #1 | ||||||||||||||||
column · DisplayString · read-only · optional Display name of this cooling fan. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanStatus | 1.3.6.1.4.1.3764.1.1.200.200.40.1.3 | AdicSensorStatus | RO | optional | 1 | ||||||||||||||||
column · AdicSensorStatus · read-only · optional Cooling fan state; - nominal, warning or alarm. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanRPM | 1.3.6.1.4.1.3764.1.1.200.200.40.1.4 | INTEGER | RO | optional | 2568 | ||||||||||||||||
column · INTEGER · read-only · optional The fan speed in revolutions per minute. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanNominalLo | 1.3.6.1.4.1.3764.1.1.200.200.40.1.5 | INTEGER | RO | optional | 0 | ||||||||||||||||
column · INTEGER · read-only · optional Lower fan speed limit of the nominal state for this fan. Units are in RPM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanNominalHi | 1.3.6.1.4.1.3764.1.1.200.200.40.1.6 | INTEGER | RO | optional | 0 | ||||||||||||||||
column · INTEGER · read-only · optional Upper fan speed limit of the nominal state for this fan. Units are in RPM. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanWarningLo | 1.3.6.1.4.1.3764.1.1.200.200.40.1.7 | INTEGER | RO | optional | 1500 | ||||||||||||||||
column · INTEGER · read-only · optional Lower fan speed limit of the warning state for this fan. Units are in RPM. If the speed falls below this limit, the fan enters the alarm state. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanWarningHi | 1.3.6.1.4.1.3764.1.1.200.200.40.1.8 | INTEGER | RO | optional | 6500 | ||||||||||||||||
column · INTEGER · read-only · optional Upper fan speed limit of the warning state for this fan. Units are in RPM. If the speed rises above this limit, the fan enters the alarm state. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanLocation | 1.3.6.1.4.1.3764.1.1.200.200.40.1.9 | DisplayString | RO | optional | 1,1,1,1,2 | ||||||||||||||||
column · DisplayString · read-only · optional Physical location of this fan. Example values from LibreNMS test devices
| |||||||||||||||||||||
| CcoolingFanREDId | 1.3.6.1.4.1.3764.1.1.200.200.40.1.10 | AdicREDIdentifier | RO | optional | 131100 | ||||||||||||||||
column · AdicREDIdentifier · read-only · optional Runtime Error Detection identifier for this fan. Example values from LibreNMS test devices
| |||||||||||||||||||||
| Nsml | 1.3.6.1.4.1.3764.1.1.300 | ||||||||||||||||||||
| Nnetwork | 1.3.6.1.4.1.3764.1.1.400 | ||||||||||||||||||||
| Nnotification | 1.3.6.1.4.1.3764.1.1.500 | ||||||||||||||||||||
| TtrapPayloadTable | 1.3.6.1.4.1.3764.1.1.500.10 | NA | mandatory | ||||||||||||||||||
table · not-accessible · mandatory Defines objects common to all trap payloads. | |||||||||||||||||||||
| RtrapPayloadEntry | 1.3.6.1.4.1.3764.1.1.500.10.1 | NA | mandatory | ||||||||||||||||||
row · not-accessible · mandatory Each entry contains the information for a specific cooling fan.
| |||||||||||||||||||||
| CtrapSequenceNumber | 1.3.6.1.4.1.3764.1.1.500.10.1.1 | INTEGER (0..65535) | RO | mandatory | |||||||||||||||||
column · INTEGER (0..65535) · read-only · mandatory The incrementing trap notification sequence number associated with this trap. | |||||||||||||||||||||
| CtrapSeverity | 1.3.6.1.4.1.3764.1.1.500.10.1.2 | AdicTrapSeverity | RO | mandatory | |||||||||||||||||
column · AdicTrapSeverity · read-only · mandatory The TRAP notification severity. | |||||||||||||||||||||
| CtrapSummaryText | 1.3.6.1.4.1.3764.1.1.500.10.1.3 | DisplayString | RO | mandatory | |||||||||||||||||
column · DisplayString · read-only · mandatory The TRAP information summary. | |||||||||||||||||||||
| CtrapIntendedUsage | 1.3.6.1.4.1.3764.1.1.500.10.1.4 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The value of this qualifier aids the management application in determining how to respond to the trap. If the value is public(1), the information is intended to be propagated to external observers, such as sending email. If the value is triggerRefresh(2), the information is intended to update the management application's data model, but not necessarily propagated to external observers.
| |||||||||||||||||||||
| CtrapInstance | 1.3.6.1.4.1.3764.1.1.500.10.1.5 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory The specifc TRAP instance for this TRAP. | |||||||||||||||||||||
| CtrapInstanceValue | 1.3.6.1.4.1.3764.1.1.500.10.1.6 | INTEGER | RO | mandatory | |||||||||||||||||
column · INTEGER · read-only · mandatory A management application specifc TRAP instance value to further TRAP response processing. | |||||||||||||||||||||
Traps / Notifications
- componentAdded
1.3.6.1.4.1.3764.1.1.0.502 - componentRemoved
1.3.6.1.4.1.3764.1.1.0.503 - productLibraryClassChange
1.3.6.1.4.1.3764.1.1.0.504 - shutdownSequenceInitiated
1.3.6.1.4.1.3764.1.1.0.501 - startupSequenceComplete
1.3.6.1.4.1.3764.1.1.0.500