ACD-DESC-MIB
accedian, Inc.The Accedian Networks device Description MIB.
snmptranslate -m ACD-DESC-MIB -Tpsnmpwalk -v2c -c <community> -m ACD-DESC-MIB <host> 1.3.6.1.4.1.22420.1.1Imports
| ACCEDIAN-SMI | acdProducts |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-MIB | sysName |
| SNMPv2-SMI | Bits, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, PhysAddress, TEXTUAL-CONVENTION, TruthValue |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IacdDesc | 1.3.6.1.4.1.22420.1.1 | ||||||||||||
identity The Accedian Networks device Description MIB. | |||||||||||||
| NacdDescNotifications | 1.3.6.1.4.1.22420.1.1.0 | ||||||||||||
| !acdPowerLost | 1.3.6.1.4.1.22420.1.1.0.1 | ||||||||||||
notification · current The SNMP trap that is generated by a unit when it detect a power lost. It's the equivalent of the 802.3ah dying gasp. | |||||||||||||
| SacdDescCommercialName | 1.3.6.1.4.1.22420.1.1.1 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current This string is to describe the type of device. | |||||||||||||
| SacdDescMacBaseAddr | 1.3.6.1.4.1.22420.1.1.2 | MacAddress | RO | ||||||||||
scalar · MacAddress · read-only · current This is the Base of the EtherNID MAC addresses. | |||||||||||||
| SacdDescIdentifier | 1.3.6.1.4.1.22420.1.1.3 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Identifies the EtherNID on your network. | |||||||||||||
| SacdDescFirmwareVersion | 1.3.6.1.4.1.22420.1.1.4 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Indicates the version of the firmware currently loaded. | |||||||||||||
| SacdDescHardwareVersion | 1.3.6.1.4.1.22420.1.1.5 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Indicates the assembly ID of the hardware. | |||||||||||||
| SacdDescSerialNumber | 1.3.6.1.4.1.22420.1.1.6 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Indicates the serial number. | |||||||||||||
| SacdDescHardwareOptions | 1.3.6.1.4.1.22420.1.1.7 | DisplayString | RO | ||||||||||
scalar · DisplayString · read-only · current Indicates the Hardware options. | |||||||||||||
| TacdDescConnectorTable | 1.3.6.1.4.1.22420.1.1.10 | NA | |||||||||||
table · not-accessible · current Table of all connectors info | |||||||||||||
| RacdDescConnectorEntry | 1.3.6.1.4.1.22420.1.1.10.1 | NA | |||||||||||
| CacdDescConnectorID | 1.3.6.1.4.1.22420.1.1.10.1.1 | Unsigned32 (1..4294967295) | NA | ||||||||||
column · Unsigned32 (1..4294967295) · not-accessible · current Unique value for each connector. Starting to one from left to right. | |||||||||||||
| CacdDescConnectorName | 1.3.6.1.4.1.22420.1.1.10.1.2 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Identifies the connector on the silkscreen. | |||||||||||||
| CacdDescConnectorType | 1.3.6.1.4.1.22420.1.1.10.1.3 | INTEGER | RO | ||||||||||
column · INTEGER · read-only · current Describe the connector type, for instance an RJ-45 or an SFP.
| |||||||||||||
| CacdDescConnectorPoESupport | 1.3.6.1.4.1.22420.1.1.10.1.4 | TruthValue | RO | ||||||||||
column · TruthValue · read-only · current This is to indicate if the port support PoE or not. | |||||||||||||
| TacdDescPwrTable | 1.3.6.1.4.1.22420.1.1.11 | NA | |||||||||||
table · not-accessible · current Table of all Power Supplies | |||||||||||||
| RacdDescPwrEntry | 1.3.6.1.4.1.22420.1.1.11.1 | NA | |||||||||||
row · not-accessible · current This is the product available power supplies information.
| |||||||||||||
| CacdDescPwrID | 1.3.6.1.4.1.22420.1.1.11.1.1 | Unsigned32 (1..4294967295) | NA | ||||||||||
column · Unsigned32 (1..4294967295) · not-accessible · current Unique value for each power supply. | |||||||||||||
| CacdDescPwrName | 1.3.6.1.4.1.22420.1.1.11.1.2 | DisplayString | RO | ||||||||||
column · DisplayString · read-only · current Identifies the power supply. | |||||||||||||
| CacdDescPwrType | 1.3.6.1.4.1.22420.1.1.11.1.3 | INTEGER | RO | ||||||||||
column · INTEGER · read-only · current Describe the Power Supply type.
| |||||||||||||
| CacdDescPwrPresent | 1.3.6.1.4.1.22420.1.1.11.1.4 | TruthValue | RO | ||||||||||
column · TruthValue · read-only · current This is to indicate if the power supply is present or not. | |||||||||||||
| TacdDescTsTable | 1.3.6.1.4.1.22420.1.1.12 | NA | |||||||||||
table · not-accessible · current Table of all Teperature Sensors. | |||||||||||||
| RacdDescTsEntry | 1.3.6.1.4.1.22420.1.1.12.1 | NA | |||||||||||
row · not-accessible · current This is the product available Temperature sensor information.
| |||||||||||||
| CacdDescTsID | 1.3.6.1.4.1.22420.1.1.12.1.1 | Unsigned32 (1..4294967295) | NA | ||||||||||
column · Unsigned32 (1..4294967295) · not-accessible · current Unique value for each Temperature Sensor. | |||||||||||||
| CacdDescTsCurrentTemp | 1.3.6.1.4.1.22420.1.1.12.1.2 | Integer32 | RO | ||||||||||
column · Integer32 · read-only · current Current temperature in Celsius around the temperature sensor. On LT and LT-S units this value is truncated and does not include the decimals. | |||||||||||||
| CacdDescTsFirstThres | 1.3.6.1.4.1.22420.1.1.12.1.3 | Integer32 | RO | ||||||||||
column · Integer32 · read-only · current Temperature value in Celsius to declare this threshold crossed. On LT and LT-S units this value is truncated and does not include the decimals. | |||||||||||||
| CacdDescTsFisrtThresPass | 1.3.6.1.4.1.22420.1.1.12.1.4 | TruthValue | RO | ||||||||||
column · TruthValue · read-only · current This is to indicate if the temperature cross the first threshold. | |||||||||||||
| CacdDescTsSecondThres | 1.3.6.1.4.1.22420.1.1.12.1.5 | Integer32 | RO | ||||||||||
column · Integer32 · read-only · current Temperature value in Celsius to declare this second threshold crossed. On LT and LT-S units this value is truncated and does not include the decimals. | |||||||||||||
| CacdDescTsSecondThresPass | 1.3.6.1.4.1.22420.1.1.12.1.6 | TruthValue | RO | ||||||||||
column · TruthValue · read-only · current This is to indicate if the temperature cross the second threshold. | |||||||||||||
| CacdDescTsLabel | 1.3.6.1.4.1.22420.1.1.12.1.7 | DisplayString (SIZE (1..63)) | RO | ||||||||||
column · DisplayString (SIZE (1..63)) · read-only · current Label of the temperature sensor. | |||||||||||||
| NacdDescMIBObjects | 1.3.6.1.4.1.22420.1.1.15 | ||||||||||||
| NacdDescConformance | 1.3.6.1.4.1.22420.1.1.15.1 | ||||||||||||
| NacdDescCompliances | 1.3.6.1.4.1.22420.1.1.15.1.1 | ||||||||||||
| MacdDescCompliance | 1.3.6.1.4.1.22420.1.1.15.1.1.1 | ||||||||||||
compliance · current The compliance statement for support of the ACD-DESC-MIB module. | |||||||||||||
| NacdDescGroups | 1.3.6.1.4.1.22420.1.1.15.1.2 | ||||||||||||
| GacdDescGenGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.1 | ||||||||||||
group · current .
| |||||||||||||
| GacdDescConnectorGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.2 | ||||||||||||
| GacdDescPwrGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.3 | ||||||||||||
| GacdDescTsGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.4 | ||||||||||||
group · current . | |||||||||||||
| GacdDescNotificationsGroup | 1.3.6.1.4.1.22420.1.1.15.1.2.5 | ||||||||||||
| SacdDescCpuUsageCurrent | 1.3.6.1.4.1.22420.1.1.20 | Gauge32 (0..100) | RO | 42 | |||||||||
scalar · Gauge32 (0..100) · read-only · current Indicates the current percentage of CPU usage.
Example values from LibreNMS test devices
| |||||||||||||
| SacdDescCpuUsageAverage15 | 1.3.6.1.4.1.22420.1.1.21 | Gauge32 (0..100) | RO | ||||||||||
scalar · Gauge32 (0..100) · read-only · current Indicates the average percentage of CPU usage over the last 15 seconds. This object range from (0..100).
| |||||||||||||
| SacdDescCpuUsageAverage30 | 1.3.6.1.4.1.22420.1.1.22 | Gauge32 (0..100) | RO | ||||||||||
scalar · Gauge32 (0..100) · read-only · current Indicates the average percentage of CPU usage over the last 30 seconds. This object range from (0..100).
| |||||||||||||
| SacdDescCpuUsageAverage60 | 1.3.6.1.4.1.22420.1.1.23 | Gauge32 (0..100) | RO | ||||||||||
scalar · Gauge32 (0..100) · read-only · current Indicates the average percentage of CPU usage over the last 60 seconds. This object range from (0..100).
| |||||||||||||
| SacdDescCpuUsageAverage900 | 1.3.6.1.4.1.22420.1.1.24 | Gauge32 (0..100) | RO | ||||||||||
scalar · Gauge32 (0..100) · read-only · current Indicates the average percentage of CPU usage over the last 900 seconds. This object range from (0..100).
| |||||||||||||
| SacdDescUptime | 1.3.6.1.4.1.22420.1.1.25 | Unsigned32 (1..4294967295) | RO | ||||||||||
scalar · Unsigned32 (1..4294967295) · read-only · current Number of seconds elapsed since boot. | |||||||||||||
Traps / Notifications
- acdPowerLost
1.3.6.1.4.1.22420.1.1.0.1