ABBMODULARUPS-MIB
ABB Power Protection SAThe MIB module to describe ABB Power Protection SA Uninterruptible Power Supplies.
snmptranslate -m ABBMODULARUPS-MIB -Tpsnmpwalk -v2c -c <community> -m ABBMODULARUPS-MIB <host> 1.3.6.1.4.1.53973Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | AutonomousType, DisplayString, PhysAddress, TEXTUAL-CONVENTION, TestAndIncr, TimeInterval, TimeStamp |
OID tree
| Name | OID | Type | Access | Status | Example | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Iabb | 1.3.6.1.4.1.53973 | ||||||||||||
identity The MIB module to describe ABB Power Protection SA Uninterruptible Power Supplies. | |||||||||||||
| Nups | 1.3.6.1.4.1.53973.1 | ||||||||||||
| NupsModular | 1.3.6.1.4.1.53973.1.1 | ||||||||||||
| NupsSystem | 1.3.6.1.4.1.53973.1.1.1 | ||||||||||||
| NupsObjects | 1.3.6.1.4.1.53973.1.1.1.1 | ||||||||||||
| NupsIdent | 1.3.6.1.4.1.53973.1.1.1.1.1 | ||||||||||||
| SupsIdentManufacturer | 1.3.6.1.4.1.53973.1.1.1.1.1.1 | DisplayString (SIZE (0..31)) | RO | ABB | |||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. Example values from LibreNMS test devices
| |||||||||||||
| SupsIdentModel | 1.3.6.1.4.1.53973.1.1.1.1.1.2 | DisplayString (SIZE (0..63)) | RO | PowerScale | |||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. Example values from LibreNMS test devices
| |||||||||||||
| SupsIdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.1.1.1.3 | DisplayString (SIZE (0..63)) | RO | 2.6 | |||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations. Example values from LibreNMS test devices
| |||||||||||||
| SupsIdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.1.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations. | |||||||||||||
| SupsIdentName | 1.3.6.1.4.1.53973.1.1.1.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| SupsIdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.1.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| NupsBattery | 1.3.6.1.4.1.53973.1.1.1.1.2 | ||||||||||||
| SupsBatteryStatus | 1.3.6.1.4.1.53973.1.1.1.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| SupsSecondsOnBattery | 1.3.6.1.4.1.53973.1.1.1.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| SupsEstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.1.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| SupsEstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.1.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| SupsBatteryVoltage | 1.3.6.1.4.1.53973.1.1.1.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| SupsBatteryCurrent | 1.3.6.1.4.1.53973.1.1.1.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| SupsBatteryTemperature | 1.3.6.1.4.1.53973.1.1.1.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| NupsInput | 1.3.6.1.4.1.53973.1.1.1.1.3 | ||||||||||||
| SupsInputLineBads | 1.3.6.1.4.1.53973.1.1.1.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| SupsInputNumLines | 1.3.6.1.4.1.53973.1.1.1.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| TupsInputTable | 1.3.6.1.4.1.53973.1.1.1.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of upsInputNumLines. | |||||||||||||
| RupsInputEntry | 1.3.6.1.4.1.53973.1.1.1.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| CupsInputLineIndex | 1.3.6.1.4.1.53973.1.1.1.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| CupsInputFrequency | 1.3.6.1.4.1.53973.1.1.1.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| CupsInputVoltage | 1.3.6.1.4.1.53973.1.1.1.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| CupsInputCurrent | 1.3.6.1.4.1.53973.1.1.1.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| NupsOutput | 1.3.6.1.4.1.53973.1.1.1.1.4 | ||||||||||||
| SupsOutputSource | 1.3.6.1.4.1.53973.1.1.1.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| SupsOutputFrequency | 1.3.6.1.4.1.53973.1.1.1.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| SupsOutputNumLines | 1.3.6.1.4.1.53973.1.1.1.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| TupsOutputTable | 1.3.6.1.4.1.53973.1.1.1.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of upsOutputNumLines. | |||||||||||||
| RupsOutputEntry | 1.3.6.1.4.1.53973.1.1.1.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| CupsOutputLineIndex | 1.3.6.1.4.1.53973.1.1.1.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| CupsOutputVoltage | 1.3.6.1.4.1.53973.1.1.1.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| CupsOutputCurrent | 1.3.6.1.4.1.53973.1.1.1.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| CupsOutputPower | 1.3.6.1.4.1.53973.1.1.1.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| CupsOutputPercentLoad | 1.3.6.1.4.1.53973.1.1.1.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| NupsBypass | 1.3.6.1.4.1.53973.1.1.1.1.5 | ||||||||||||
| SupsBypassFrequency | 1.3.6.1.4.1.53973.1.1.1.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| SupsBypassNumLines | 1.3.6.1.4.1.53973.1.1.1.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| TupsBypassTable | 1.3.6.1.4.1.53973.1.1.1.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines. | |||||||||||||
| RupsBypassEntry | 1.3.6.1.4.1.53973.1.1.1.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| CupsBypassLineIndex | 1.3.6.1.4.1.53973.1.1.1.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| CupsBypassVoltage | 1.3.6.1.4.1.53973.1.1.1.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| CupsBypassCurrent | 1.3.6.1.4.1.53973.1.1.1.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| CupsBypassPower | 1.3.6.1.4.1.53973.1.1.1.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| NupsAlarm | 1.3.6.1.4.1.53973.1.1.1.1.6 | ||||||||||||
| SupsAlarmsPresent | 1.3.6.1.4.1.53973.1.1.1.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| TupsAlarmTable | 1.3.6.1.4.1.53973.1.1.1.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent. | |||||||||||||
| RupsAlarmEntry | 1.3.6.1.4.1.53973.1.1.1.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| CupsAlarmId | 1.3.6.1.4.1.53973.1.1.1.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| CupsAlarmDescr | 1.3.6.1.4.1.53973.1.1.1.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| CupsAlarmTime | 1.3.6.1.4.1.53973.1.1.1.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0. | |||||||||||||
| NupsWellKnownAlarms | 1.3.6.1.4.1.53973.1.1.1.1.6.3 | ||||||||||||
| NupsAlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.1.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| NupsAlarmOnBattery | 1.3.6.1.4.1.53973.1.1.1.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| NupsAlarmLowBattery | 1.3.6.1.4.1.53973.1.1.1.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to upsConfigLowBattTime. | |||||||||||||
| NupsAlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.1.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| NupsAlarmTempBad | 1.3.6.1.4.1.53973.1.1.1.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| NupsAlarmInputBad | 1.3.6.1.4.1.53973.1.1.1.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| NupsAlarmOutputBad | 1.3.6.1.4.1.53973.1.1.1.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| NupsAlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.1.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| NupsAlarmOnBypass | 1.3.6.1.4.1.53973.1.1.1.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| NupsAlarmBypassBad | 1.3.6.1.4.1.53973.1.1.1.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| NupsAlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.1.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| NupsAlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.1.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| NupsAlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.1.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| NupsAlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.1.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| NupsAlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.1.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| NupsAlarmFanFailure | 1.3.6.1.4.1.53973.1.1.1.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| NupsAlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.1.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| NupsAlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.1.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| NupsAlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.1.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| NupsAlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.1.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| NupsAlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.1.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| NupsAlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.1.1.6.3.22 | ||||||||||||
node · current A upsShutdownAfterDelay countdown is underway. | |||||||||||||
| NupsAlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.1.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| NupsAlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.1.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| NupsTest | 1.3.6.1.4.1.53973.1.1.1.1.7 | ||||||||||||
| SupsTestId | 1.3.6.1.4.1.53973.1.1.1.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in upsTestResultsSummary. Tests in progress may be aborted by setting the upsTestId variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value upsTestNoTestsInitiated is returned. | |||||||||||||
| SupsTestSpinLock | 1.3.6.1.4.1.53973.1.1.1.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = upsTestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, upsTestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
upsTestResultsSummary */
get (upsTestSpinLock, upsTestResultsSummary,
upsTestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, upsTestResultsSummary,
upsTestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if upsTestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of upsTestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| SupsTestResultsSummary | 1.3.6.1.4.1.53973.1.1.1.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| SupsTestResultsDetail | 1.3.6.1.4.1.53973.1.1.1.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| SupsTestStartTime | 1.3.6.1.4.1.53973.1.1.1.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0. | |||||||||||||
| SupsTestElapsedTime | 1.3.6.1.4.1.53973.1.1.1.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0. | |||||||||||||
| NupsWellKnownTests | 1.3.6.1.4.1.53973.1.1.1.1.7.7 | ||||||||||||
| NupsTestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.1.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| NupsTestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.1.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| NupsTestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.1.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| NupsTestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.1.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| NupsTestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.1.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| NupsControl | 1.3.6.1.4.1.53973.1.1.1.1.8 | ||||||||||||
| SupsShutdownType | 1.3.6.1.4.1.53973.1.1.1.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| SupsShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.1.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if upsShutdownType = system and the system is already off. Similarly, there is no additional action at that time if upsShutdownType = output and the output is already off. When read, upsShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any upsShutdownAfterDelay already in effect.
| |||||||||||||
| SupsStartupAfterDelay | 1.3.6.1.4.1.53973.1.1.1.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| SupsRebootWithDuration | 1.3.6.1.4.1.53973.1.1.1.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| NupsTraps | 1.3.6.1.4.1.53973.1.1.1.2 | ||||||||||||
| !upsTrapOnBattery | 1.3.6.1.4.1.53973.1.1.1.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !upsTrapTestCompleted | 1.3.6.1.4.1.53973.1.1.1.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !upsTrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.1.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for upsAlarmOnBattery and upsAlarmTestInProgress.
| |||||||||||||
| !upsTrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.1.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for upsAlarmTestInProgress.
| |||||||||||||
| NupsConformance | 1.3.6.1.4.1.53973.1.1.1.3 | ||||||||||||
| NupsCompliances | 1.3.6.1.4.1.53973.1.1.1.3.1 | ||||||||||||
| MupsSubsetCompliance | 1.3.6.1.4.1.53973.1.1.1.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| MupsBasicCompliance | 1.3.6.1.4.1.53973.1.1.1.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| MupsFullCompliance | 1.3.6.1.4.1.53973.1.1.1.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| NupsGroups | 1.3.6.1.4.1.53973.1.1.1.3.2 | ||||||||||||
| NupsSubsetGroups | 1.3.6.1.4.1.53973.1.1.1.3.2.1 | ||||||||||||
| GupsSubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.1.1 | ||||||||||||
group · current The upsSubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the upsSubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| GupsSubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.1.2 | ||||||||||||
group · current The upsSubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs.
| |||||||||||||
| GupsSubsetInputGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.1.3 | ||||||||||||
group · current The upsSubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| GupsSubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.1.4 | ||||||||||||
group · current The upsSubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| GupsSubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.1.6 | ||||||||||||
group · current The upsSubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs.
| |||||||||||||
| GupsSubsetControlGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.1.8 | ||||||||||||
group · current The upsSubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs.
| |||||||||||||
| NupsBasicGroups | 1.3.6.1.4.1.53973.1.1.1.3.2.2 | ||||||||||||
| GupsBasicIdentGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.1 | ||||||||||||
group · current The upsBasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| GupsBasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.2 | ||||||||||||
group · current The upsBasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions.
| |||||||||||||
| GupsBasicInputGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.3 | ||||||||||||
group · current The upsBasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| GupsBasicOutputGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.4 | ||||||||||||
group · current The upsBasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| GupsBasicBypassGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.5 | ||||||||||||
group · current The upsBasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| GupsBasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.6 | ||||||||||||
group · current The upsBasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions.
| |||||||||||||
| GupsBasicTestGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.7 | ||||||||||||
group · current The upsBasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| GupsBasicControlGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.2.8 | ||||||||||||
group · current The upsBasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| NupsFullGroups | 1.3.6.1.4.1.53973.1.1.1.3.2.3 | ||||||||||||
| GupsFullIdentGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.1 | ||||||||||||
group · current The upsFullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| GupsFullBatteryGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.2 | ||||||||||||
group · current The upsFullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| GupsFullInputGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.3 | ||||||||||||
group · current The upsFullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| GupsFullOutputGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.4 | ||||||||||||
group · current The upsFullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| GupsFullBypassGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.5 | ||||||||||||
group · current The upsFullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| GupsFullAlarmGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.6 | ||||||||||||
group · current The upsFullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs.
| |||||||||||||
| GupsFullTestGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.7 | ||||||||||||
group · current The upsFullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| GupsFullControlGroup | 1.3.6.1.4.1.53973.1.1.1.3.2.3.8 | ||||||||||||
group · current The upsFullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| SupsModularDiscoveredUPSsMask | 1.3.6.1.4.1.53973.1.1.1.4 | Unsigned32 | RO | ||||||||||
scalar · Unsigned32 · read-only · current Reading this variable returns bit mask indicating which
module in a parallel system is alive.
1 Module 1 alive
2 Module 2 alive
4 Module 3 alive
8 Module 4 alive
16 Module 5 alive
32 Module 6 alive
64 Module 7 alive
128 Module 8 alive
256 Module 9 alive
512 Module 10 alive
1024 Module 11 alive
2048 Module 12 alive
4096 Module 13 alive
8192 Module 14 alive
16384 Module 15 alive
32768 Module 16 alive
65536 Module 17 alive
131072 Module 18 alive
262144 Module 19 alive
524288 Module 20 alive
1048576 Module 21 alive
2097152 Module 22 alive
4194304 Module 23 alive
8388608 Module 24 alive
16777216 Module 25 alive
33554432 Module 26 alive
67108864 Module 27 alive
134217728 Module 28 alive
268435456 Module 29 alive
536870912 Module 30 alive | |||||||||||||
| NupsModule1 | 1.3.6.1.4.1.53973.1.1.2 | ||||||||||||
| Nups01Objects | 1.3.6.1.4.1.53973.1.1.2.1 | ||||||||||||
| Nups01Ident | 1.3.6.1.4.1.53973.1.1.2.1.1 | ||||||||||||
| Sups01IdentManufacturer | 1.3.6.1.4.1.53973.1.1.2.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups01IdentModel | 1.3.6.1.4.1.53973.1.1.2.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups01IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.2.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups01IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups01IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.2.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups01IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups01IdentName | 1.3.6.1.4.1.53973.1.1.2.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups01IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.2.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups01Battery | 1.3.6.1.4.1.53973.1.1.2.1.2 | ||||||||||||
| Sups01BatteryStatus | 1.3.6.1.4.1.53973.1.1.2.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups01ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups01ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups01SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.2.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups01EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.2.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups01EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.2.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups01BatteryVoltage | 1.3.6.1.4.1.53973.1.1.2.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups01BatteryCurrent | 1.3.6.1.4.1.53973.1.1.2.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups01BatteryTemperature | 1.3.6.1.4.1.53973.1.1.2.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups01Input | 1.3.6.1.4.1.53973.1.1.2.1.3 | ||||||||||||
| Sups01InputLineBads | 1.3.6.1.4.1.53973.1.1.2.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups01InputNumLines | 1.3.6.1.4.1.53973.1.1.2.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups01InputTable | 1.3.6.1.4.1.53973.1.1.2.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups01InputNumLines. | |||||||||||||
| Rups01InputEntry | 1.3.6.1.4.1.53973.1.1.2.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups01InputLineIndex | 1.3.6.1.4.1.53973.1.1.2.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups01InputFrequency | 1.3.6.1.4.1.53973.1.1.2.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups01InputVoltage | 1.3.6.1.4.1.53973.1.1.2.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups01InputCurrent | 1.3.6.1.4.1.53973.1.1.2.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups01InputTruePower | 1.3.6.1.4.1.53973.1.1.2.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups01Output | 1.3.6.1.4.1.53973.1.1.2.1.4 | ||||||||||||
| Sups01OutputSource | 1.3.6.1.4.1.53973.1.1.2.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups01OutputFrequency | 1.3.6.1.4.1.53973.1.1.2.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups01OutputNumLines | 1.3.6.1.4.1.53973.1.1.2.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups01OutputTable | 1.3.6.1.4.1.53973.1.1.2.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups01OutputNumLines. | |||||||||||||
| Rups01OutputEntry | 1.3.6.1.4.1.53973.1.1.2.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups01OutputLineIndex | 1.3.6.1.4.1.53973.1.1.2.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups01OutputVoltage | 1.3.6.1.4.1.53973.1.1.2.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups01OutputCurrent | 1.3.6.1.4.1.53973.1.1.2.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups01OutputPower | 1.3.6.1.4.1.53973.1.1.2.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups01OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.2.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups01Bypass | 1.3.6.1.4.1.53973.1.1.2.1.5 | ||||||||||||
| Sups01BypassFrequency | 1.3.6.1.4.1.53973.1.1.2.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups01BypassNumLines | 1.3.6.1.4.1.53973.1.1.2.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups01BypassTable | 1.3.6.1.4.1.53973.1.1.2.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups01BypassNumLines. | |||||||||||||
| Rups01BypassEntry | 1.3.6.1.4.1.53973.1.1.2.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups01BypassLineIndex | 1.3.6.1.4.1.53973.1.1.2.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups01BypassVoltage | 1.3.6.1.4.1.53973.1.1.2.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups01BypassCurrent | 1.3.6.1.4.1.53973.1.1.2.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups01BypassPower | 1.3.6.1.4.1.53973.1.1.2.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups01Alarm | 1.3.6.1.4.1.53973.1.1.2.1.6 | ||||||||||||
| Sups01AlarmsPresent | 1.3.6.1.4.1.53973.1.1.2.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups01AlarmTable | 1.3.6.1.4.1.53973.1.1.2.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups01AlarmId equal to 1, and increments the value of ups01AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups01AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups01AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups01AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups01AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups01AlarmsPresent. | |||||||||||||
| Rups01AlarmEntry | 1.3.6.1.4.1.53973.1.1.2.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups01AlarmId | 1.3.6.1.4.1.53973.1.1.2.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups01AlarmDescr | 1.3.6.1.4.1.53973.1.1.2.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups01AlarmTime | 1.3.6.1.4.1.53973.1.1.2.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups01AlarmTime shall equal 0. | |||||||||||||
| Nups01WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.2.1.6.3 | ||||||||||||
| Nups01AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.2.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups01AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.2.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups01AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.2.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups01ConfigLowBattTime. | |||||||||||||
| Nups01AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.2.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups01AlarmTempBad | 1.3.6.1.4.1.53973.1.1.2.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups01AlarmInputBad | 1.3.6.1.4.1.53973.1.1.2.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups01AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.2.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups01AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.2.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups01AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.2.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups01AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.2.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups01AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.2.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups01AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.2.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups01AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.2.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups01AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.2.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups01AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.2.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups01AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.2.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups01AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.2.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups01AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.2.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups01AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.2.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups01AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.2.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups01AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.2.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups01AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.2.1.6.3.22 | ||||||||||||
node · current A ups01ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups01AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.2.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups01AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.2.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups01Test | 1.3.6.1.4.1.53973.1.1.2.1.7 | ||||||||||||
| Sups01TestId | 1.3.6.1.4.1.53973.1.1.2.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups01TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups01TestResultsSummary. Tests in progress may be aborted by setting the ups01TestId variable to ups01TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups01TestNoTestsInitiated is returned. | |||||||||||||
| Sups01TestSpinLock | 1.3.6.1.4.1.53973.1.1.2.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (ups01TestSpinLock)
while (ups01TestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (ups01TestSpinLock)
}
lock_value = ups01TestSpinLock
/* no test in progress, start the test */
set (ups01TestSpinLock = lock_value, ups01TestId =
requested_test)
if (error_index == 1) { /* (ups01TestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (ups01TestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups01TestResultsSummary */
get (ups01TestSpinLock, ups01TestResultsSummary,
ups01TestResultsDetail)
while (ups01TestResultsSummary == inProgress) {
short delay
get (ups01TestSpinLock, ups01TestResultsSummary,
ups01TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups01TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups01TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups01TestResultsSummary | 1.3.6.1.4.1.53973.1.1.2.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups01TestId to ups01TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups01TestResultsDetail | 1.3.6.1.4.1.53973.1.1.2.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups01TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups01TestStartTime | 1.3.6.1.4.1.53973.1.1.2.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups01TestResultsSummary is noTestsInitiated(6), ups01TestStartTime has the value 0. | |||||||||||||
| Sups01TestElapsedTime | 1.3.6.1.4.1.53973.1.1.2.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups01TestResultsSummary is noTestsInitiated(6), ups01TestElapsedTime has the value 0. | |||||||||||||
| Nups01WellKnownTests | 1.3.6.1.4.1.53973.1.1.2.1.7.7 | ||||||||||||
| Nups01TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.2.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups01TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.2.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups01TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.2.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups01TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.2.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups01TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.2.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups01Control | 1.3.6.1.4.1.53973.1.1.2.1.8 | ||||||||||||
| Sups01ShutdownType | 1.3.6.1.4.1.53973.1.1.2.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups01ShutdownAfterDelay and ups01RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups01ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.2.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups01ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups01ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups01ShutdownType = output and the output is already off. When read, ups01ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups01ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups01StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.2.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups01StartupAfterDelay countdown or ups01RebootWithDuration countdown in progress. When read, ups01StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups01RebootWithDuration | 1.3.6.1.4.1.53973.1.1.2.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups01ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups01RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups01Traps | 1.3.6.1.4.1.53973.1.1.2.2 | ||||||||||||
| !ups01TrapOnBattery | 1.3.6.1.4.1.53973.1.1.2.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups01TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.2.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups01TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.2.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups01AlarmOnBattery and ups01AlarmTestInProgress.
| |||||||||||||
| !ups01TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.2.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups01AlarmTestInProgress.
| |||||||||||||
| Nups01Conformance | 1.3.6.1.4.1.53973.1.1.2.3 | ||||||||||||
| Nups01Compliances | 1.3.6.1.4.1.53973.1.1.2.3.1 | ||||||||||||
| Mups01SubsetCompliance | 1.3.6.1.4.1.53973.1.1.2.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups01BasicCompliance | 1.3.6.1.4.1.53973.1.1.2.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups01FullCompliance | 1.3.6.1.4.1.53973.1.1.2.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups01Groups | 1.3.6.1.4.1.53973.1.1.2.3.2 | ||||||||||||
| Nups01SubsetGroups | 1.3.6.1.4.1.53973.1.1.2.3.2.1 | ||||||||||||
| Gups01SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.1.1 | ||||||||||||
group · current The ups01SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups01SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups01SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.1.2 | ||||||||||||
group · current The ups01SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups01SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.1.3 | ||||||||||||
group · current The ups01SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups01SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.1.4 | ||||||||||||
group · current The ups01SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups01SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.1.6 | ||||||||||||
group · current The ups01SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups01SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.1.8 | ||||||||||||
group · current The ups01SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups01BasicGroups | 1.3.6.1.4.1.53973.1.1.2.3.2.2 | ||||||||||||
| Gups01BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.1 | ||||||||||||
group · current The ups01BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups01BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.2 | ||||||||||||
group · current The ups01BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups01BasicInputGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.3 | ||||||||||||
group · current The ups01BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups01BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.4 | ||||||||||||
group · current The ups01BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups01BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.5 | ||||||||||||
group · current The ups01BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups01BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.6 | ||||||||||||
group · current The ups01BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups01BasicTestGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.7 | ||||||||||||
group · current The ups01BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups01BasicControlGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.2.8 | ||||||||||||
group · current The ups01BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups01FullGroups | 1.3.6.1.4.1.53973.1.1.2.3.2.3 | ||||||||||||
| Gups01FullIdentGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.1 | ||||||||||||
group · current The ups01FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups01FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.2 | ||||||||||||
group · current The ups01FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups01FullInputGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.3 | ||||||||||||
group · current The ups01FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups01FullOutputGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.4 | ||||||||||||
group · current The ups01FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups01FullBypassGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.5 | ||||||||||||
group · current The ups01FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups01FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.6 | ||||||||||||
group · current The ups01FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups01FullTestGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.7 | ||||||||||||
group · current The ups01FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups01FullControlGroup | 1.3.6.1.4.1.53973.1.1.2.3.2.3.8 | ||||||||||||
group · current The ups01FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule2 | 1.3.6.1.4.1.53973.1.1.3 | ||||||||||||
| Nups02Objects | 1.3.6.1.4.1.53973.1.1.3.1 | ||||||||||||
| Nups02Ident | 1.3.6.1.4.1.53973.1.1.3.1.1 | ||||||||||||
| Sups02IdentManufacturer | 1.3.6.1.4.1.53973.1.1.3.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups02IdentModel | 1.3.6.1.4.1.53973.1.1.3.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups02IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.3.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups02IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.3.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups02IdentName | 1.3.6.1.4.1.53973.1.1.3.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups02IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.3.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups02Battery | 1.3.6.1.4.1.53973.1.1.3.1.2 | ||||||||||||
| Sups02BatteryStatus | 1.3.6.1.4.1.53973.1.1.3.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups02SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.3.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups02EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.3.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups02EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.3.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups02BatteryVoltage | 1.3.6.1.4.1.53973.1.1.3.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups02BatteryCurrent | 1.3.6.1.4.1.53973.1.1.3.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups02BatteryTemperature | 1.3.6.1.4.1.53973.1.1.3.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups02Input | 1.3.6.1.4.1.53973.1.1.3.1.3 | ||||||||||||
| Sups02InputLineBads | 1.3.6.1.4.1.53973.1.1.3.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups02InputNumLines | 1.3.6.1.4.1.53973.1.1.3.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups02InputTable | 1.3.6.1.4.1.53973.1.1.3.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of upsInputNumLines. | |||||||||||||
| Rups02InputEntry | 1.3.6.1.4.1.53973.1.1.3.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups02InputLineIndex | 1.3.6.1.4.1.53973.1.1.3.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups02InputFrequency | 1.3.6.1.4.1.53973.1.1.3.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups02InputVoltage | 1.3.6.1.4.1.53973.1.1.3.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups02InputCurrent | 1.3.6.1.4.1.53973.1.1.3.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups02InputTruePower | 1.3.6.1.4.1.53973.1.1.3.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups02Output | 1.3.6.1.4.1.53973.1.1.3.1.4 | ||||||||||||
| Sups02OutputSource | 1.3.6.1.4.1.53973.1.1.3.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups02OutputFrequency | 1.3.6.1.4.1.53973.1.1.3.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups02OutputNumLines | 1.3.6.1.4.1.53973.1.1.3.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups02OutputTable | 1.3.6.1.4.1.53973.1.1.3.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups02OutputNumLines. | |||||||||||||
| Rups02OutputEntry | 1.3.6.1.4.1.53973.1.1.3.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups02OutputLineIndex | 1.3.6.1.4.1.53973.1.1.3.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups02OutputVoltage | 1.3.6.1.4.1.53973.1.1.3.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups02OutputCurrent | 1.3.6.1.4.1.53973.1.1.3.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups02OutputPower | 1.3.6.1.4.1.53973.1.1.3.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups02OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.3.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups02Bypass | 1.3.6.1.4.1.53973.1.1.3.1.5 | ||||||||||||
| Sups02BypassFrequency | 1.3.6.1.4.1.53973.1.1.3.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups02BypassNumLines | 1.3.6.1.4.1.53973.1.1.3.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups02BypassTable | 1.3.6.1.4.1.53973.1.1.3.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups02BypassNumLines. | |||||||||||||
| Rups02BypassEntry | 1.3.6.1.4.1.53973.1.1.3.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups02BypassLineIndex | 1.3.6.1.4.1.53973.1.1.3.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups02BypassVoltage | 1.3.6.1.4.1.53973.1.1.3.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups02BypassCurrent | 1.3.6.1.4.1.53973.1.1.3.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups02BypassPower | 1.3.6.1.4.1.53973.1.1.3.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups02Alarm | 1.3.6.1.4.1.53973.1.1.3.1.6 | ||||||||||||
| Sups02AlarmsPresent | 1.3.6.1.4.1.53973.1.1.3.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups02AlarmTable | 1.3.6.1.4.1.53973.1.1.3.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups02AlarmId equal to 1, and increments the value of ups02AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups02AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups02AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups02AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups02AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups02AlarmsPresent. | |||||||||||||
| Rups02AlarmEntry | 1.3.6.1.4.1.53973.1.1.3.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups02AlarmId | 1.3.6.1.4.1.53973.1.1.3.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups02AlarmDescr | 1.3.6.1.4.1.53973.1.1.3.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups02AlarmTime | 1.3.6.1.4.1.53973.1.1.3.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups02AlarmTime shall equal 0. | |||||||||||||
| Nups02WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.3.1.6.3 | ||||||||||||
| Nups02AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.3.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups02AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.3.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups02AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.3.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups02ConfigLowBattTime. | |||||||||||||
| Nups02AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.3.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups02AlarmTempBad | 1.3.6.1.4.1.53973.1.1.3.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups02AlarmInputBad | 1.3.6.1.4.1.53973.1.1.3.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups02AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.3.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups02AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.3.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups02AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.3.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups02AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.3.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups02AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.3.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups02AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.3.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups02AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.3.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups02AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.3.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups02AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.3.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups02AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.3.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups02AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.3.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups02AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.3.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups02AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.3.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups02AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.3.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups02AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.3.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups02AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.3.1.6.3.22 | ||||||||||||
node · current A upsShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups02AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.3.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups02AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.3.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups02Test | 1.3.6.1.4.1.53973.1.1.3.1.7 | ||||||||||||
| Sups02TestId | 1.3.6.1.4.1.53973.1.1.3.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups02TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups02TestResultsSummary. Tests in progress may be aborted by setting the ups02TestId variable to ups02TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups02TestNoTestsInitiated is returned. | |||||||||||||
| Sups02TestSpinLock | 1.3.6.1.4.1.53973.1.1.3.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (ups02TestSpinLock)
while (ups02TestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (ups02TestSpinLock)
}
lock_value = ups02TestSpinLock
/* no test in progress, start the test */
set (ups02TestSpinLock = lock_value, upsTestId =
requested_test)
if (error_index == 1) { /* (ups02TestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (ups02TestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups02TestResultsSummary */
get (ups02TestSpinLock, ups02TestResultsSummary,
ups02TestResultsDetail)
while (ups02TestResultsSummary == inProgress) {
short delay
get (ups02TestSpinLock, ups02TestResultsSummary,
ups02TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups02TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups02TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups02TestResultsSummary | 1.3.6.1.4.1.53973.1.1.3.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups02TestId to ups02TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups02TestResultsDetail | 1.3.6.1.4.1.53973.1.1.3.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups02TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups02TestStartTime | 1.3.6.1.4.1.53973.1.1.3.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups02TestResultsSummary is noTestsInitiated(6), ups02TestStartTime has the value 0. | |||||||||||||
| Sups02TestElapsedTime | 1.3.6.1.4.1.53973.1.1.3.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups02TestResultsSummary is noTestsInitiated(6), ups02TestElapsedTime has the value 0. | |||||||||||||
| Nups02WellKnownTests | 1.3.6.1.4.1.53973.1.1.3.1.7.7 | ||||||||||||
| Nups02TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.3.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups02TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.3.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups02TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.3.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups02TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.3.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups02TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.3.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups02Control | 1.3.6.1.4.1.53973.1.1.3.1.8 | ||||||||||||
| Sups02ShutdownType | 1.3.6.1.4.1.53973.1.1.3.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups02ShutdownAfterDelay and ups02RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups02ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.3.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups02ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups02ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups02ShutdownType = output and the output is already off. When read, ups02ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups02ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups02StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.3.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups02StartupAfterDelay countdown or ups02RebootWithDuration countdown in progress. When read, ups02StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups02RebootWithDuration | 1.3.6.1.4.1.53973.1.1.3.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups02ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups02RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups02Traps | 1.3.6.1.4.1.53973.1.1.3.2 | ||||||||||||
| !ups02TrapOnBattery | 1.3.6.1.4.1.53973.1.1.3.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups02TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.3.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups02TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.3.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups02AlarmOnBattery and upsAlarmTestInProgress.
| |||||||||||||
| !ups02TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.3.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups02AlarmTestInProgress.
| |||||||||||||
| Nups02Conformance | 1.3.6.1.4.1.53973.1.1.3.3 | ||||||||||||
| Nups02Compliances | 1.3.6.1.4.1.53973.1.1.3.3.1 | ||||||||||||
| Mups02SubsetCompliance | 1.3.6.1.4.1.53973.1.1.3.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups02BasicCompliance | 1.3.6.1.4.1.53973.1.1.3.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups02FullCompliance | 1.3.6.1.4.1.53973.1.1.3.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups02Groups | 1.3.6.1.4.1.53973.1.1.3.3.2 | ||||||||||||
| Nups02SubsetGroups | 1.3.6.1.4.1.53973.1.1.3.3.2.1 | ||||||||||||
| Gups02SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.1.1 | ||||||||||||
group · current The ups02SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups02SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups02SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.1.2 | ||||||||||||
group · current The ups02SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups02SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.1.3 | ||||||||||||
group · current The ups02SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups02SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.1.4 | ||||||||||||
group · current The ups02SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups02SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.1.6 | ||||||||||||
group · current The ups02SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups02SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.1.8 | ||||||||||||
group · current The ups02SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups02BasicGroups | 1.3.6.1.4.1.53973.1.1.3.3.2.2 | ||||||||||||
| Gups02BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.1 | ||||||||||||
group · current The ups02BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups02BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.2 | ||||||||||||
group · current The ups02BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups02BasicInputGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.3 | ||||||||||||
group · current The ups02BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups02BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.4 | ||||||||||||
group · current The ups02BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups02BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.5 | ||||||||||||
group · current The ups02BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups02BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.6 | ||||||||||||
group · current The ups02BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups02BasicTestGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.7 | ||||||||||||
group · current The ups02BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups02BasicControlGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.2.8 | ||||||||||||
group · current The ups02BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups02FullGroups | 1.3.6.1.4.1.53973.1.1.3.3.2.3 | ||||||||||||
| Gups02FullIdentGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.1 | ||||||||||||
group · current The ups02FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups02FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.2 | ||||||||||||
group · current The ups02FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups02FullInputGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.3 | ||||||||||||
group · current The ups02FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups02FullOutputGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.4 | ||||||||||||
group · current The ups02FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups02FullBypassGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.5 | ||||||||||||
group · current The ups02FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups02FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.6 | ||||||||||||
group · current The ups02FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups02FullTestGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.7 | ||||||||||||
group · current The ups02FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups02FullControlGroup | 1.3.6.1.4.1.53973.1.1.3.3.2.3.8 | ||||||||||||
group · current The ups02FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule3 | 1.3.6.1.4.1.53973.1.1.4 | ||||||||||||
| Nups03Objects | 1.3.6.1.4.1.53973.1.1.4.1 | ||||||||||||
| Nups03Ident | 1.3.6.1.4.1.53973.1.1.4.1.1 | ||||||||||||
| Sups03IdentManufacturer | 1.3.6.1.4.1.53973.1.1.4.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups03IdentModel | 1.3.6.1.4.1.53973.1.1.4.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups03IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.4.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups03IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups03IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.4.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups03IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups03IdentName | 1.3.6.1.4.1.53973.1.1.4.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups03IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.4.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups03Battery | 1.3.6.1.4.1.53973.1.1.4.1.2 | ||||||||||||
| Sups03BatteryStatus | 1.3.6.1.4.1.53973.1.1.4.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups03ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups03ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups03SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.4.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups03EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.4.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups03EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.4.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups03BatteryVoltage | 1.3.6.1.4.1.53973.1.1.4.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups03BatteryCurrent | 1.3.6.1.4.1.53973.1.1.4.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups03BatteryTemperature | 1.3.6.1.4.1.53973.1.1.4.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups03Input | 1.3.6.1.4.1.53973.1.1.4.1.3 | ||||||||||||
| Sups03InputLineBads | 1.3.6.1.4.1.53973.1.1.4.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups03InputNumLines | 1.3.6.1.4.1.53973.1.1.4.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups03InputTable | 1.3.6.1.4.1.53973.1.1.4.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups03InputNumLines. | |||||||||||||
| Rups03InputEntry | 1.3.6.1.4.1.53973.1.1.4.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups03InputLineIndex | 1.3.6.1.4.1.53973.1.1.4.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups03InputFrequency | 1.3.6.1.4.1.53973.1.1.4.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups03InputVoltage | 1.3.6.1.4.1.53973.1.1.4.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups03InputCurrent | 1.3.6.1.4.1.53973.1.1.4.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups03InputTruePower | 1.3.6.1.4.1.53973.1.1.4.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups03Output | 1.3.6.1.4.1.53973.1.1.4.1.4 | ||||||||||||
| Sups03OutputSource | 1.3.6.1.4.1.53973.1.1.4.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups03OutputFrequency | 1.3.6.1.4.1.53973.1.1.4.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups03OutputNumLines | 1.3.6.1.4.1.53973.1.1.4.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups03OutputTable | 1.3.6.1.4.1.53973.1.1.4.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups03OutputNumLines. | |||||||||||||
| Rups03OutputEntry | 1.3.6.1.4.1.53973.1.1.4.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups03OutputLineIndex | 1.3.6.1.4.1.53973.1.1.4.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups03OutputVoltage | 1.3.6.1.4.1.53973.1.1.4.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups03OutputCurrent | 1.3.6.1.4.1.53973.1.1.4.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups03OutputPower | 1.3.6.1.4.1.53973.1.1.4.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups03OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.4.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups03Bypass | 1.3.6.1.4.1.53973.1.1.4.1.5 | ||||||||||||
| Sups03BypassFrequency | 1.3.6.1.4.1.53973.1.1.4.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups03BypassNumLines | 1.3.6.1.4.1.53973.1.1.4.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups03BypassTable | 1.3.6.1.4.1.53973.1.1.4.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups03BypassNumLines. | |||||||||||||
| Rups03BypassEntry | 1.3.6.1.4.1.53973.1.1.4.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups03BypassLineIndex | 1.3.6.1.4.1.53973.1.1.4.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups03BypassVoltage | 1.3.6.1.4.1.53973.1.1.4.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups03BypassCurrent | 1.3.6.1.4.1.53973.1.1.4.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups03BypassPower | 1.3.6.1.4.1.53973.1.1.4.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups03Alarm | 1.3.6.1.4.1.53973.1.1.4.1.6 | ||||||||||||
| Sups03AlarmsPresent | 1.3.6.1.4.1.53973.1.1.4.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups03AlarmTable | 1.3.6.1.4.1.53973.1.1.4.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups03AlarmId equal to 1, and increments the value of ups03AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups03AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups03AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups03AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups03AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups03AlarmsPresent. | |||||||||||||
| Rups03AlarmEntry | 1.3.6.1.4.1.53973.1.1.4.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups03AlarmId | 1.3.6.1.4.1.53973.1.1.4.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups03AlarmDescr | 1.3.6.1.4.1.53973.1.1.4.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups03AlarmTime | 1.3.6.1.4.1.53973.1.1.4.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups03AlarmTime shall equal 0. | |||||||||||||
| Nups03WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.4.1.6.3 | ||||||||||||
| Nups03AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.4.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups03AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.4.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups03AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.4.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups03ConfigLowBattTime. | |||||||||||||
| Nups03AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.4.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups03AlarmTempBad | 1.3.6.1.4.1.53973.1.1.4.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups03AlarmInputBad | 1.3.6.1.4.1.53973.1.1.4.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups03AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.4.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups03AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.4.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups03AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.4.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups03AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.4.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups03AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.4.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups03AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.4.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups03AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.4.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups03AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.4.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups03AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.4.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups03AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.4.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups03AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.4.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups03AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.4.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups03AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.4.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups03AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.4.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups03AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.4.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups03AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.4.1.6.3.22 | ||||||||||||
node · current A ups03ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups03AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.4.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups03AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.4.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups03Test | 1.3.6.1.4.1.53973.1.1.4.1.7 | ||||||||||||
| Sups03TestId | 1.3.6.1.4.1.53973.1.1.4.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups03TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups03TestResultsSummary. Tests in progress may be aborted by setting the ups03TestId variable to ups03TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups03TestNoTestsInitiated is returned. | |||||||||||||
| Sups03TestSpinLock | 1.3.6.1.4.1.53973.1.1.4.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups03TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups03TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups03TestResultsSummary */
get (upsTestSpinLock, ups03TestResultsSummary,
ups03TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups03TestResultsSummary,
ups03TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups03TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups03TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups03TestResultsSummary | 1.3.6.1.4.1.53973.1.1.4.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups03TestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups03TestResultsDetail | 1.3.6.1.4.1.53973.1.1.4.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups03TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups03TestStartTime | 1.3.6.1.4.1.53973.1.1.4.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups03TestResultsSummary is noTestsInitiated(6), ups03TestStartTime has the value 0. | |||||||||||||
| Sups03TestElapsedTime | 1.3.6.1.4.1.53973.1.1.4.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups03TestResultsSummary is noTestsInitiated(6), ups03TestElapsedTime has the value 0. | |||||||||||||
| Nups03WellKnownTests | 1.3.6.1.4.1.53973.1.1.4.1.7.7 | ||||||||||||
| Nups03TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.4.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups03TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.4.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups03TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.4.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups03TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.4.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups03TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.4.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups03Control | 1.3.6.1.4.1.53973.1.1.4.1.8 | ||||||||||||
| Sups03ShutdownType | 1.3.6.1.4.1.53973.1.1.4.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups03ShutdownAfterDelay and upsRebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups03ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.4.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups03ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups03ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups03ShutdownType = output and the output is already off. When read, ups03ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups03ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups03StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.4.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups03StartupAfterDelay countdown or ups03RebootWithDuration countdown in progress. When read, ups03StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups03RebootWithDuration | 1.3.6.1.4.1.53973.1.1.4.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups03ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups03RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups03Traps | 1.3.6.1.4.1.53973.1.1.4.2 | ||||||||||||
| !ups03TrapOnBattery | 1.3.6.1.4.1.53973.1.1.4.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups03TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.4.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups03TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.4.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups03AlarmOnBattery and ups03AlarmTestInProgress.
| |||||||||||||
| !ups03TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.4.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups03AlarmTestInProgress.
| |||||||||||||
| Nups03Conformance | 1.3.6.1.4.1.53973.1.1.4.3 | ||||||||||||
| Nups03Compliances | 1.3.6.1.4.1.53973.1.1.4.3.1 | ||||||||||||
| Mups03SubsetCompliance | 1.3.6.1.4.1.53973.1.1.4.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups03BasicCompliance | 1.3.6.1.4.1.53973.1.1.4.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups03FullCompliance | 1.3.6.1.4.1.53973.1.1.4.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups03Groups | 1.3.6.1.4.1.53973.1.1.4.3.2 | ||||||||||||
| Nups03SubsetGroups | 1.3.6.1.4.1.53973.1.1.4.3.2.1 | ||||||||||||
| Gups03SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.1.1 | ||||||||||||
group · current The ups03SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups03SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups03SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.1.2 | ||||||||||||
group · current The ups03SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups03SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.1.3 | ||||||||||||
group · current The ups03SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups03SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.1.4 | ||||||||||||
group · current The ups03SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups03SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.1.6 | ||||||||||||
group · current The ups03SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups03SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.1.8 | ||||||||||||
group · current The ups03SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups03BasicGroups | 1.3.6.1.4.1.53973.1.1.4.3.2.2 | ||||||||||||
| Gups03BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.1 | ||||||||||||
group · current The ups03BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups03BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.2 | ||||||||||||
group · current The ups03BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups03BasicInputGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.3 | ||||||||||||
group · current The ups03BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups03BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.4 | ||||||||||||
group · current The ups03BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups03BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.5 | ||||||||||||
group · current The ups03BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups03BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.6 | ||||||||||||
group · current The ups03BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups03BasicTestGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.7 | ||||||||||||
group · current The ups03BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups03BasicControlGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.2.8 | ||||||||||||
group · current The ups03BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups03FullGroups | 1.3.6.1.4.1.53973.1.1.4.3.2.3 | ||||||||||||
| Gups03FullIdentGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.1 | ||||||||||||
group · current The ups03FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups03FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.2 | ||||||||||||
group · current The ups03FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups03FullInputGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.3 | ||||||||||||
group · current The ups03FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups03FullOutputGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.4 | ||||||||||||
group · current The ups03FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups03FullBypassGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.5 | ||||||||||||
group · current The ups03FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups03FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.6 | ||||||||||||
group · current The ups03FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups03FullTestGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.7 | ||||||||||||
group · current The ups03FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups03FullControlGroup | 1.3.6.1.4.1.53973.1.1.4.3.2.3.8 | ||||||||||||
group · current The ups03FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule4 | 1.3.6.1.4.1.53973.1.1.5 | ||||||||||||
| Nups04Objects | 1.3.6.1.4.1.53973.1.1.5.1 | ||||||||||||
| Nups04Ident | 1.3.6.1.4.1.53973.1.1.5.1.1 | ||||||||||||
| Sups04IdentManufacturer | 1.3.6.1.4.1.53973.1.1.5.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups04IdentModel | 1.3.6.1.4.1.53973.1.1.5.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups04IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.5.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups04IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups04IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.5.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups04IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups04IdentName | 1.3.6.1.4.1.53973.1.1.5.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups04IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.5.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups04Battery | 1.3.6.1.4.1.53973.1.1.5.1.2 | ||||||||||||
| Sups04BatteryStatus | 1.3.6.1.4.1.53973.1.1.5.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups04ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups04ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups04SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.5.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups04EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.5.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups04EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.5.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups04BatteryVoltage | 1.3.6.1.4.1.53973.1.1.5.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups04BatteryCurrent | 1.3.6.1.4.1.53973.1.1.5.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups04BatteryTemperature | 1.3.6.1.4.1.53973.1.1.5.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups04Input | 1.3.6.1.4.1.53973.1.1.5.1.3 | ||||||||||||
| Sups04InputLineBads | 1.3.6.1.4.1.53973.1.1.5.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups04InputNumLines | 1.3.6.1.4.1.53973.1.1.5.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups04InputTable | 1.3.6.1.4.1.53973.1.1.5.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups04InputNumLines. | |||||||||||||
| Rups04InputEntry | 1.3.6.1.4.1.53973.1.1.5.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups04InputLineIndex | 1.3.6.1.4.1.53973.1.1.5.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups04InputFrequency | 1.3.6.1.4.1.53973.1.1.5.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups04InputVoltage | 1.3.6.1.4.1.53973.1.1.5.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups04InputCurrent | 1.3.6.1.4.1.53973.1.1.5.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups04InputTruePower | 1.3.6.1.4.1.53973.1.1.5.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups04Output | 1.3.6.1.4.1.53973.1.1.5.1.4 | ||||||||||||
| Sups04OutputSource | 1.3.6.1.4.1.53973.1.1.5.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups04OutputFrequency | 1.3.6.1.4.1.53973.1.1.5.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups04OutputNumLines | 1.3.6.1.4.1.53973.1.1.5.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups04OutputTable | 1.3.6.1.4.1.53973.1.1.5.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups04OutputNumLines. | |||||||||||||
| Rups04OutputEntry | 1.3.6.1.4.1.53973.1.1.5.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups04OutputLineIndex | 1.3.6.1.4.1.53973.1.1.5.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups04OutputVoltage | 1.3.6.1.4.1.53973.1.1.5.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups04OutputCurrent | 1.3.6.1.4.1.53973.1.1.5.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups04OutputPower | 1.3.6.1.4.1.53973.1.1.5.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups04OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.5.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups04Bypass | 1.3.6.1.4.1.53973.1.1.5.1.5 | ||||||||||||
| Sups04BypassFrequency | 1.3.6.1.4.1.53973.1.1.5.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups04BypassNumLines | 1.3.6.1.4.1.53973.1.1.5.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups04BypassTable | 1.3.6.1.4.1.53973.1.1.5.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups04BypassNumLines. | |||||||||||||
| Rups04BypassEntry | 1.3.6.1.4.1.53973.1.1.5.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups04BypassLineIndex | 1.3.6.1.4.1.53973.1.1.5.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups04BypassVoltage | 1.3.6.1.4.1.53973.1.1.5.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups04BypassCurrent | 1.3.6.1.4.1.53973.1.1.5.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups04BypassPower | 1.3.6.1.4.1.53973.1.1.5.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups04Alarm | 1.3.6.1.4.1.53973.1.1.5.1.6 | ||||||||||||
| Sups04AlarmsPresent | 1.3.6.1.4.1.53973.1.1.5.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups04AlarmTable | 1.3.6.1.4.1.53973.1.1.5.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups04AlarmId equal to 1, and increments the value of ups04AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups04AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups04AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups04AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups04AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups04AlarmsPresent. | |||||||||||||
| Rups04AlarmEntry | 1.3.6.1.4.1.53973.1.1.5.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups04AlarmId | 1.3.6.1.4.1.53973.1.1.5.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups04AlarmDescr | 1.3.6.1.4.1.53973.1.1.5.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups04AlarmTime | 1.3.6.1.4.1.53973.1.1.5.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups04AlarmTime shall equal 0. | |||||||||||||
| Nups04WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.5.1.6.3 | ||||||||||||
| Nups04AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.5.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups04AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.5.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups04AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.5.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups04ConfigLowBattTime. | |||||||||||||
| Nups04AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.5.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups04AlarmTempBad | 1.3.6.1.4.1.53973.1.1.5.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups04AlarmInputBad | 1.3.6.1.4.1.53973.1.1.5.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups04AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.5.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups04AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.5.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups04AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.5.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups04AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.5.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups04AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.5.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups04AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.5.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups04AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.5.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups04AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.5.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups04AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.5.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups04AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.5.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups04AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.5.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups04AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.5.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups04AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.5.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups04AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.5.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups04AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.5.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups04AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.5.1.6.3.22 | ||||||||||||
node · current A ups04ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups04AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.5.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups04AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.5.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups04Test | 1.3.6.1.4.1.53973.1.1.5.1.7 | ||||||||||||
| Sups04TestId | 1.3.6.1.4.1.53973.1.1.5.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups04TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups04TestResultsSummary. Tests in progress may be aborted by setting the ups04TestId variable to ups04TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups04TestNoTestsInitiated is returned. | |||||||||||||
| Sups04TestSpinLock | 1.3.6.1.4.1.53973.1.1.5.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups04TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups04TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups04TestResultsSummary */
get (upsTestSpinLock, ups04TestResultsSummary,
ups04TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups04TestResultsSummary,
ups04TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups04TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups04TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups04TestResultsSummary | 1.3.6.1.4.1.53973.1.1.5.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups04TestId to ups04TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups04TestResultsDetail | 1.3.6.1.4.1.53973.1.1.5.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups04TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups04TestStartTime | 1.3.6.1.4.1.53973.1.1.5.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups04TestResultsSummary is noTestsInitiated(6), ups04TestStartTime has the value 0. | |||||||||||||
| Sups04TestElapsedTime | 1.3.6.1.4.1.53973.1.1.5.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups04TestResultsSummary is noTestsInitiated(6), ups04TestElapsedTime has the value 0. | |||||||||||||
| Nups04WellKnownTests | 1.3.6.1.4.1.53973.1.1.5.1.7.7 | ||||||||||||
| Nups04TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.5.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups04TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.5.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups04TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.5.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups04TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.5.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups04TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.5.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups04Control | 1.3.6.1.4.1.53973.1.1.5.1.8 | ||||||||||||
| Sups04ShutdownType | 1.3.6.1.4.1.53973.1.1.5.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups04ShutdownAfterDelay and ups04RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups04ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.5.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups04ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups04ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups04ShutdownType = output and the output is already off. When read, ups04ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups04ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups04StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.5.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups04StartupAfterDelay countdown or ups04RebootWithDuration countdown in progress. When read, ups04StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups04RebootWithDuration | 1.3.6.1.4.1.53973.1.1.5.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups04ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups04RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups04Traps | 1.3.6.1.4.1.53973.1.1.5.2 | ||||||||||||
| !ups04TrapOnBattery | 1.3.6.1.4.1.53973.1.1.5.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups04TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.5.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups04TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.5.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups04AlarmOnBattery and ups04AlarmTestInProgress.
| |||||||||||||
| !ups04TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.5.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups04AlarmTestInProgress.
| |||||||||||||
| Nups04Conformance | 1.3.6.1.4.1.53973.1.1.5.3 | ||||||||||||
| Nups04Compliances | 1.3.6.1.4.1.53973.1.1.5.3.1 | ||||||||||||
| Mups04SubsetCompliance | 1.3.6.1.4.1.53973.1.1.5.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups04BasicCompliance | 1.3.6.1.4.1.53973.1.1.5.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups04FullCompliance | 1.3.6.1.4.1.53973.1.1.5.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups04Groups | 1.3.6.1.4.1.53973.1.1.5.3.2 | ||||||||||||
| Nups04SubsetGroups | 1.3.6.1.4.1.53973.1.1.5.3.2.1 | ||||||||||||
| Gups04SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.1.1 | ||||||||||||
group · current The ups04SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups04SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups04SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.1.2 | ||||||||||||
group · current The ups04SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups04SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.1.3 | ||||||||||||
group · current The ups04SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups04SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.1.4 | ||||||||||||
group · current The ups04SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups04SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.1.6 | ||||||||||||
group · current The ups04SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups04SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.1.8 | ||||||||||||
group · current The ups04SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups04BasicGroups | 1.3.6.1.4.1.53973.1.1.5.3.2.2 | ||||||||||||
| Gups04BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.1 | ||||||||||||
group · current The ups04BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups04BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.2 | ||||||||||||
group · current The ups04BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups04BasicInputGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.3 | ||||||||||||
group · current The ups04BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups04BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.4 | ||||||||||||
group · current The ups04BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups04BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.5 | ||||||||||||
group · current The ups04BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups04BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.6 | ||||||||||||
group · current The ups04BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups04BasicTestGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.7 | ||||||||||||
group · current The ups04BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups04BasicControlGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.2.8 | ||||||||||||
group · current The ups04BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups04FullGroups | 1.3.6.1.4.1.53973.1.1.5.3.2.3 | ||||||||||||
| Gups04FullIdentGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.1 | ||||||||||||
group · current The ups04FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups04FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.2 | ||||||||||||
group · current The ups04FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups04FullInputGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.3 | ||||||||||||
group · current The ups04FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups04FullOutputGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.4 | ||||||||||||
group · current The ups04FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups04FullBypassGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.5 | ||||||||||||
group · current The ups04FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups04FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.6 | ||||||||||||
group · current The ups04FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups04FullTestGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.7 | ||||||||||||
group · current The ups04FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups04FullControlGroup | 1.3.6.1.4.1.53973.1.1.5.3.2.3.8 | ||||||||||||
group · current The ups04FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule5 | 1.3.6.1.4.1.53973.1.1.6 | ||||||||||||
| Nups05Objects | 1.3.6.1.4.1.53973.1.1.6.1 | ||||||||||||
| Nups05Ident | 1.3.6.1.4.1.53973.1.1.6.1.1 | ||||||||||||
| Sups05IdentManufacturer | 1.3.6.1.4.1.53973.1.1.6.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups05IdentModel | 1.3.6.1.4.1.53973.1.1.6.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups05IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.6.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups05IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups05IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.6.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups05IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups05IdentName | 1.3.6.1.4.1.53973.1.1.6.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups05IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.6.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups05Battery | 1.3.6.1.4.1.53973.1.1.6.1.2 | ||||||||||||
| Sups05BatteryStatus | 1.3.6.1.4.1.53973.1.1.6.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups05ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups05ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups05SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.6.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups05EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.6.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups05EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.6.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups05BatteryVoltage | 1.3.6.1.4.1.53973.1.1.6.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups05BatteryCurrent | 1.3.6.1.4.1.53973.1.1.6.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups05BatteryTemperature | 1.3.6.1.4.1.53973.1.1.6.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups05Input | 1.3.6.1.4.1.53973.1.1.6.1.3 | ||||||||||||
| Sups05InputLineBads | 1.3.6.1.4.1.53973.1.1.6.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups05InputNumLines | 1.3.6.1.4.1.53973.1.1.6.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups05InputTable | 1.3.6.1.4.1.53973.1.1.6.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups05InputNumLines. | |||||||||||||
| Rups05InputEntry | 1.3.6.1.4.1.53973.1.1.6.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups05InputLineIndex | 1.3.6.1.4.1.53973.1.1.6.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups05InputFrequency | 1.3.6.1.4.1.53973.1.1.6.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups05InputVoltage | 1.3.6.1.4.1.53973.1.1.6.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups05InputCurrent | 1.3.6.1.4.1.53973.1.1.6.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups05InputTruePower | 1.3.6.1.4.1.53973.1.1.6.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups05Output | 1.3.6.1.4.1.53973.1.1.6.1.4 | ||||||||||||
| Sups05OutputSource | 1.3.6.1.4.1.53973.1.1.6.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups05OutputFrequency | 1.3.6.1.4.1.53973.1.1.6.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups05OutputNumLines | 1.3.6.1.4.1.53973.1.1.6.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups05OutputTable | 1.3.6.1.4.1.53973.1.1.6.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups05OutputNumLines. | |||||||||||||
| Rups05OutputEntry | 1.3.6.1.4.1.53973.1.1.6.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups05OutputLineIndex | 1.3.6.1.4.1.53973.1.1.6.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups05OutputVoltage | 1.3.6.1.4.1.53973.1.1.6.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups05OutputCurrent | 1.3.6.1.4.1.53973.1.1.6.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups05OutputPower | 1.3.6.1.4.1.53973.1.1.6.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups05OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.6.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups05Bypass | 1.3.6.1.4.1.53973.1.1.6.1.5 | ||||||||||||
| Sups05BypassFrequency | 1.3.6.1.4.1.53973.1.1.6.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups05BypassNumLines | 1.3.6.1.4.1.53973.1.1.6.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups05BypassTable | 1.3.6.1.4.1.53973.1.1.6.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups05BypassNumLines. | |||||||||||||
| Rups05BypassEntry | 1.3.6.1.4.1.53973.1.1.6.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups05BypassLineIndex | 1.3.6.1.4.1.53973.1.1.6.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups05BypassVoltage | 1.3.6.1.4.1.53973.1.1.6.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups05BypassCurrent | 1.3.6.1.4.1.53973.1.1.6.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups05BypassPower | 1.3.6.1.4.1.53973.1.1.6.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups05Alarm | 1.3.6.1.4.1.53973.1.1.6.1.6 | ||||||||||||
| Sups05AlarmsPresent | 1.3.6.1.4.1.53973.1.1.6.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups05AlarmTable | 1.3.6.1.4.1.53973.1.1.6.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups05AlarmId equal to 1, and increments the value of ups05AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups05AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups05AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups05AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups05AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups05AlarmsPresent. | |||||||||||||
| Rups05AlarmEntry | 1.3.6.1.4.1.53973.1.1.6.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups05AlarmId | 1.3.6.1.4.1.53973.1.1.6.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups05AlarmDescr | 1.3.6.1.4.1.53973.1.1.6.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups05AlarmTime | 1.3.6.1.4.1.53973.1.1.6.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups05AlarmTime shall equal 0. | |||||||||||||
| Nups05WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.6.1.6.3 | ||||||||||||
| Nups05AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.6.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups05AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.6.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups05AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.6.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups05ConfigLowBattTime. | |||||||||||||
| Nups05AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.6.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups05AlarmTempBad | 1.3.6.1.4.1.53973.1.1.6.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups05AlarmInputBad | 1.3.6.1.4.1.53973.1.1.6.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups05AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.6.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups05AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.6.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups05AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.6.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups05AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.6.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups05AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.6.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups05AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.6.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups05AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.6.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups05AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.6.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups05AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.6.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups05AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.6.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups05AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.6.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups05AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.6.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups05AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.6.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups05AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.6.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups05AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.6.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups05AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.6.1.6.3.22 | ||||||||||||
node · current A ups05ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups05AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.6.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups05AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.6.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups05Test | 1.3.6.1.4.1.53973.1.1.6.1.7 | ||||||||||||
| Sups05TestId | 1.3.6.1.4.1.53973.1.1.6.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups05TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups05TestResultsSummary. Tests in progress may be aborted by setting the ups05TestId variable to ups05TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups05TestNoTestsInitiated is returned. | |||||||||||||
| Sups05TestSpinLock | 1.3.6.1.4.1.53973.1.1.6.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups05TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups05TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups05TestResultsSummary */
get (upsTestSpinLock, ups05TestResultsSummary,
ups05TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups05TestResultsSummary,
ups05TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups05TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups05TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups05TestResultsSummary | 1.3.6.1.4.1.53973.1.1.6.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups05TestId to ups05TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups05TestResultsDetail | 1.3.6.1.4.1.53973.1.1.6.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups05TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups05TestStartTime | 1.3.6.1.4.1.53973.1.1.6.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups05TestResultsSummary is noTestsInitiated(6), ups05TestStartTime has the value 0. | |||||||||||||
| Sups05TestElapsedTime | 1.3.6.1.4.1.53973.1.1.6.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups05TestResultsSummary is noTestsInitiated(6), ups05TestElapsedTime has the value 0. | |||||||||||||
| Nups05WellKnownTests | 1.3.6.1.4.1.53973.1.1.6.1.7.7 | ||||||||||||
| Nups05TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.6.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups05TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.6.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups05TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.6.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups05TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.6.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups05TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.6.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups05Control | 1.3.6.1.4.1.53973.1.1.6.1.8 | ||||||||||||
| Sups05ShutdownType | 1.3.6.1.4.1.53973.1.1.6.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups05ShutdownAfterDelay and ups05RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups05ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.6.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups05ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups05ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups05ShutdownType = output and the output is already off. When read, ups05ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups05ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups05StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.6.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups05StartupAfterDelay countdown or ups05RebootWithDuration countdown in progress. When read, ups05StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups05RebootWithDuration | 1.3.6.1.4.1.53973.1.1.6.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups05ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups05RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups05Traps | 1.3.6.1.4.1.53973.1.1.6.2 | ||||||||||||
| !ups05TrapOnBattery | 1.3.6.1.4.1.53973.1.1.6.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups05TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.6.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups05TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.6.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups05AlarmOnBattery and ups05AlarmTestInProgress.
| |||||||||||||
| !ups05TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.6.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups05AlarmTestInProgress.
| |||||||||||||
| Nups05Conformance | 1.3.6.1.4.1.53973.1.1.6.3 | ||||||||||||
| Nups05Compliances | 1.3.6.1.4.1.53973.1.1.6.3.1 | ||||||||||||
| Mups05SubsetCompliance | 1.3.6.1.4.1.53973.1.1.6.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups05BasicCompliance | 1.3.6.1.4.1.53973.1.1.6.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups05FullCompliance | 1.3.6.1.4.1.53973.1.1.6.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups05Groups | 1.3.6.1.4.1.53973.1.1.6.3.2 | ||||||||||||
| Nups05SubsetGroups | 1.3.6.1.4.1.53973.1.1.6.3.2.1 | ||||||||||||
| Gups05SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.1.1 | ||||||||||||
group · current The ups05SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups05SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups05SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.1.2 | ||||||||||||
group · current The ups05SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups05SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.1.3 | ||||||||||||
group · current The ups05SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups05SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.1.4 | ||||||||||||
group · current The ups05SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups05SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.1.6 | ||||||||||||
group · current The ups05SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups05SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.1.8 | ||||||||||||
group · current The ups05SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups05BasicGroups | 1.3.6.1.4.1.53973.1.1.6.3.2.2 | ||||||||||||
| Gups05BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.1 | ||||||||||||
group · current The ups05BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups05BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.2 | ||||||||||||
group · current The ups05BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups05BasicInputGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.3 | ||||||||||||
group · current The ups05BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups05BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.4 | ||||||||||||
group · current The ups05BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups05BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.5 | ||||||||||||
group · current The ups05BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups05BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.6 | ||||||||||||
group · current The ups05BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups05BasicTestGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.7 | ||||||||||||
group · current The ups05BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups05BasicControlGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.2.8 | ||||||||||||
group · current The ups05BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups05FullGroups | 1.3.6.1.4.1.53973.1.1.6.3.2.3 | ||||||||||||
| Gups05FullIdentGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.1 | ||||||||||||
group · current The ups05FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups05FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.2 | ||||||||||||
group · current The ups05FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups05FullInputGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.3 | ||||||||||||
group · current The ups05FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups05FullOutputGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.4 | ||||||||||||
group · current The ups05FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups05FullBypassGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.5 | ||||||||||||
group · current The ups05FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups05FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.6 | ||||||||||||
group · current The ups05FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups05FullTestGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.7 | ||||||||||||
group · current The ups05FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups05FullControlGroup | 1.3.6.1.4.1.53973.1.1.6.3.2.3.8 | ||||||||||||
group · current The ups05FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule6 | 1.3.6.1.4.1.53973.1.1.7 | ||||||||||||
| Nups06Objects | 1.3.6.1.4.1.53973.1.1.7.1 | ||||||||||||
| Nups06Ident | 1.3.6.1.4.1.53973.1.1.7.1.1 | ||||||||||||
| Sups06IdentManufacturer | 1.3.6.1.4.1.53973.1.1.7.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups06IdentModel | 1.3.6.1.4.1.53973.1.1.7.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups06IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.7.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups06IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups06IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.7.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups06IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups06IdentName | 1.3.6.1.4.1.53973.1.1.7.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups06IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.7.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups06Battery | 1.3.6.1.4.1.53973.1.1.7.1.2 | ||||||||||||
| Sups06BatteryStatus | 1.3.6.1.4.1.53973.1.1.7.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups06ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups06ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups06SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.7.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups06EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.7.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups06EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.7.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups06BatteryVoltage | 1.3.6.1.4.1.53973.1.1.7.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups06BatteryCurrent | 1.3.6.1.4.1.53973.1.1.7.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups06BatteryTemperature | 1.3.6.1.4.1.53973.1.1.7.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups06Input | 1.3.6.1.4.1.53973.1.1.7.1.3 | ||||||||||||
| Sups06InputLineBads | 1.3.6.1.4.1.53973.1.1.7.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups06InputNumLines | 1.3.6.1.4.1.53973.1.1.7.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups06InputTable | 1.3.6.1.4.1.53973.1.1.7.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups06InputNumLines. | |||||||||||||
| Rups06InputEntry | 1.3.6.1.4.1.53973.1.1.7.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups06InputLineIndex | 1.3.6.1.4.1.53973.1.1.7.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups06InputFrequency | 1.3.6.1.4.1.53973.1.1.7.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups06InputVoltage | 1.3.6.1.4.1.53973.1.1.7.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups06InputCurrent | 1.3.6.1.4.1.53973.1.1.7.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups06InputTruePower | 1.3.6.1.4.1.53973.1.1.7.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups06Output | 1.3.6.1.4.1.53973.1.1.7.1.4 | ||||||||||||
| Sups06OutputSource | 1.3.6.1.4.1.53973.1.1.7.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups06OutputFrequency | 1.3.6.1.4.1.53973.1.1.7.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups06OutputNumLines | 1.3.6.1.4.1.53973.1.1.7.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups06OutputTable | 1.3.6.1.4.1.53973.1.1.7.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups06OutputNumLines. | |||||||||||||
| Rups06OutputEntry | 1.3.6.1.4.1.53973.1.1.7.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups06OutputLineIndex | 1.3.6.1.4.1.53973.1.1.7.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups06OutputVoltage | 1.3.6.1.4.1.53973.1.1.7.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups06OutputCurrent | 1.3.6.1.4.1.53973.1.1.7.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups06OutputPower | 1.3.6.1.4.1.53973.1.1.7.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups06OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.7.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups06Bypass | 1.3.6.1.4.1.53973.1.1.7.1.5 | ||||||||||||
| Sups06BypassFrequency | 1.3.6.1.4.1.53973.1.1.7.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups06BypassNumLines | 1.3.6.1.4.1.53973.1.1.7.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups06BypassTable | 1.3.6.1.4.1.53973.1.1.7.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups06BypassNumLines. | |||||||||||||
| Rups06BypassEntry | 1.3.6.1.4.1.53973.1.1.7.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups06BypassLineIndex | 1.3.6.1.4.1.53973.1.1.7.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups06BypassVoltage | 1.3.6.1.4.1.53973.1.1.7.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups06BypassCurrent | 1.3.6.1.4.1.53973.1.1.7.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups06BypassPower | 1.3.6.1.4.1.53973.1.1.7.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups06Alarm | 1.3.6.1.4.1.53973.1.1.7.1.6 | ||||||||||||
| Sups06AlarmsPresent | 1.3.6.1.4.1.53973.1.1.7.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups06AlarmTable | 1.3.6.1.4.1.53973.1.1.7.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups06AlarmId equal to 1, and increments the value of ups06AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups06AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups06AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups06AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups06AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups06AlarmsPresent. | |||||||||||||
| Rups06AlarmEntry | 1.3.6.1.4.1.53973.1.1.7.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups06AlarmId | 1.3.6.1.4.1.53973.1.1.7.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups06AlarmDescr | 1.3.6.1.4.1.53973.1.1.7.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups06AlarmTime | 1.3.6.1.4.1.53973.1.1.7.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups06AlarmTime shall equal 0. | |||||||||||||
| Nups06WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.7.1.6.3 | ||||||||||||
| Nups06AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.7.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups06AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.7.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups06AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.7.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups06ConfigLowBattTime. | |||||||||||||
| Nups06AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.7.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups06AlarmTempBad | 1.3.6.1.4.1.53973.1.1.7.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups06AlarmInputBad | 1.3.6.1.4.1.53973.1.1.7.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups06AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.7.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups06AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.7.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups06AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.7.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups06AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.7.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups06AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.7.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups06AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.7.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups06AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.7.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups06AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.7.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups06AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.7.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups06AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.7.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups06AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.7.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups06AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.7.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups06AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.7.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups06AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.7.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups06AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.7.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups06AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.7.1.6.3.22 | ||||||||||||
node · current A ups06ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups06AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.7.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups06AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.7.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups06Test | 1.3.6.1.4.1.53973.1.1.7.1.7 | ||||||||||||
| Sups06TestId | 1.3.6.1.4.1.53973.1.1.7.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups06TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups06TestResultsSummary. Tests in progress may be aborted by setting the ups06TestId variable to ups06TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups06TestNoTestsInitiated is returned. | |||||||||||||
| Sups06TestSpinLock | 1.3.6.1.4.1.53973.1.1.7.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups06TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups06TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups06TestResultsSummary */
get (upsTestSpinLock, ups06TestResultsSummary,
ups06TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups06TestResultsSummary,
ups06TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups06TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups06TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups06TestResultsSummary | 1.3.6.1.4.1.53973.1.1.7.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups06TestId to ups06TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups06TestResultsDetail | 1.3.6.1.4.1.53973.1.1.7.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups06TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups06TestStartTime | 1.3.6.1.4.1.53973.1.1.7.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups06TestResultsSummary is noTestsInitiated(6), ups06TestStartTime has the value 0. | |||||||||||||
| Sups06TestElapsedTime | 1.3.6.1.4.1.53973.1.1.7.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups06TestResultsSummary is noTestsInitiated(6), ups06TestElapsedTime has the value 0. | |||||||||||||
| Nups06WellKnownTests | 1.3.6.1.4.1.53973.1.1.7.1.7.7 | ||||||||||||
| Nups06TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.7.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups06TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.7.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups06TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.7.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups06TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.7.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups06TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.7.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups06Control | 1.3.6.1.4.1.53973.1.1.7.1.8 | ||||||||||||
| Sups06ShutdownType | 1.3.6.1.4.1.53973.1.1.7.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups06ShutdownAfterDelay and ups06RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups06ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.7.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups06ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups06ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups06ShutdownType = output and the output is already off. When read, ups06ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups06ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups06StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.7.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups06StartupAfterDelay countdown or ups06RebootWithDuration countdown in progress. When read, ups06StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups06RebootWithDuration | 1.3.6.1.4.1.53973.1.1.7.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups06ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups06RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups06Traps | 1.3.6.1.4.1.53973.1.1.7.2 | ||||||||||||
| !ups06TrapOnBattery | 1.3.6.1.4.1.53973.1.1.7.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups06TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.7.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups06TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.7.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups06AlarmOnBattery and ups06AlarmTestInProgress.
| |||||||||||||
| !ups06TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.7.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups06AlarmTestInProgress.
| |||||||||||||
| Nups06Conformance | 1.3.6.1.4.1.53973.1.1.7.3 | ||||||||||||
| Nups06Compliances | 1.3.6.1.4.1.53973.1.1.7.3.1 | ||||||||||||
| Mups06SubsetCompliance | 1.3.6.1.4.1.53973.1.1.7.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups06BasicCompliance | 1.3.6.1.4.1.53973.1.1.7.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups06FullCompliance | 1.3.6.1.4.1.53973.1.1.7.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups06Groups | 1.3.6.1.4.1.53973.1.1.7.3.2 | ||||||||||||
| Nups06SubsetGroups | 1.3.6.1.4.1.53973.1.1.7.3.2.1 | ||||||||||||
| Gups06SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.1.1 | ||||||||||||
group · current The ups06SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups06SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups06SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.1.2 | ||||||||||||
group · current The ups06SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups06SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.1.3 | ||||||||||||
group · current The ups06SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups06SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.1.4 | ||||||||||||
group · current The ups06SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups06SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.1.6 | ||||||||||||
group · current The ups06SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups06SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.1.8 | ||||||||||||
group · current The ups06SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups06BasicGroups | 1.3.6.1.4.1.53973.1.1.7.3.2.2 | ||||||||||||
| Gups06BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.1 | ||||||||||||
group · current The ups06BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups06BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.2 | ||||||||||||
group · current The ups06BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups06BasicInputGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.3 | ||||||||||||
group · current The ups06BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups06BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.4 | ||||||||||||
group · current The ups06BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups06BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.5 | ||||||||||||
group · current The ups06BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups06BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.6 | ||||||||||||
group · current The ups06BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups06BasicTestGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.7 | ||||||||||||
group · current The ups06BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups06BasicControlGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.2.8 | ||||||||||||
group · current The ups06BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups06FullGroups | 1.3.6.1.4.1.53973.1.1.7.3.2.3 | ||||||||||||
| Gups06FullIdentGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.1 | ||||||||||||
group · current The ups06FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups06FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.2 | ||||||||||||
group · current The ups06FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups06FullInputGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.3 | ||||||||||||
group · current The ups06FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups06FullOutputGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.4 | ||||||||||||
group · current The ups06FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups06FullBypassGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.5 | ||||||||||||
group · current The ups06FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups06FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.6 | ||||||||||||
group · current The ups06FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups06FullTestGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.7 | ||||||||||||
group · current The ups06FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups06FullControlGroup | 1.3.6.1.4.1.53973.1.1.7.3.2.3.8 | ||||||||||||
group · current The ups06FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule7 | 1.3.6.1.4.1.53973.1.1.8 | ||||||||||||
| Nups07Objects | 1.3.6.1.4.1.53973.1.1.8.1 | ||||||||||||
| Nups07Ident | 1.3.6.1.4.1.53973.1.1.8.1.1 | ||||||||||||
| Sups07IdentManufacturer | 1.3.6.1.4.1.53973.1.1.8.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups07IdentModel | 1.3.6.1.4.1.53973.1.1.8.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups07IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.8.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups07IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups07IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.8.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups07IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups07IdentName | 1.3.6.1.4.1.53973.1.1.8.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups07IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.8.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups07Battery | 1.3.6.1.4.1.53973.1.1.8.1.2 | ||||||||||||
| Sups07BatteryStatus | 1.3.6.1.4.1.53973.1.1.8.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups07ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups07ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups07SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.8.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups07EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.8.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups07EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.8.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups07BatteryVoltage | 1.3.6.1.4.1.53973.1.1.8.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups07BatteryCurrent | 1.3.6.1.4.1.53973.1.1.8.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups07BatteryTemperature | 1.3.6.1.4.1.53973.1.1.8.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups07Input | 1.3.6.1.4.1.53973.1.1.8.1.3 | ||||||||||||
| Sups07InputLineBads | 1.3.6.1.4.1.53973.1.1.8.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups07InputNumLines | 1.3.6.1.4.1.53973.1.1.8.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups07InputTable | 1.3.6.1.4.1.53973.1.1.8.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups07InputNumLines. | |||||||||||||
| Rups07InputEntry | 1.3.6.1.4.1.53973.1.1.8.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups07InputLineIndex | 1.3.6.1.4.1.53973.1.1.8.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups07InputFrequency | 1.3.6.1.4.1.53973.1.1.8.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups07InputVoltage | 1.3.6.1.4.1.53973.1.1.8.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups07InputCurrent | 1.3.6.1.4.1.53973.1.1.8.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups07InputTruePower | 1.3.6.1.4.1.53973.1.1.8.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups07Output | 1.3.6.1.4.1.53973.1.1.8.1.4 | ||||||||||||
| Sups07OutputSource | 1.3.6.1.4.1.53973.1.1.8.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups07OutputFrequency | 1.3.6.1.4.1.53973.1.1.8.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups07OutputNumLines | 1.3.6.1.4.1.53973.1.1.8.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups07OutputTable | 1.3.6.1.4.1.53973.1.1.8.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups07OutputNumLines. | |||||||||||||
| Rups07OutputEntry | 1.3.6.1.4.1.53973.1.1.8.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups07OutputLineIndex | 1.3.6.1.4.1.53973.1.1.8.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups07OutputVoltage | 1.3.6.1.4.1.53973.1.1.8.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups07OutputCurrent | 1.3.6.1.4.1.53973.1.1.8.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups07OutputPower | 1.3.6.1.4.1.53973.1.1.8.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups07OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.8.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups07Bypass | 1.3.6.1.4.1.53973.1.1.8.1.5 | ||||||||||||
| Sups07BypassFrequency | 1.3.6.1.4.1.53973.1.1.8.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups07BypassNumLines | 1.3.6.1.4.1.53973.1.1.8.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups07BypassTable | 1.3.6.1.4.1.53973.1.1.8.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups07BypassNumLines. | |||||||||||||
| Rups07BypassEntry | 1.3.6.1.4.1.53973.1.1.8.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups07BypassLineIndex | 1.3.6.1.4.1.53973.1.1.8.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups07BypassVoltage | 1.3.6.1.4.1.53973.1.1.8.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups07BypassCurrent | 1.3.6.1.4.1.53973.1.1.8.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups07BypassPower | 1.3.6.1.4.1.53973.1.1.8.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups07Alarm | 1.3.6.1.4.1.53973.1.1.8.1.6 | ||||||||||||
| Sups07AlarmsPresent | 1.3.6.1.4.1.53973.1.1.8.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups07AlarmTable | 1.3.6.1.4.1.53973.1.1.8.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups07AlarmId equal to 1, and increments the value of ups07AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups07AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups07AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups07AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups07AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups07AlarmsPresent. | |||||||||||||
| Rups07AlarmEntry | 1.3.6.1.4.1.53973.1.1.8.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups07AlarmId | 1.3.6.1.4.1.53973.1.1.8.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups07AlarmDescr | 1.3.6.1.4.1.53973.1.1.8.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups07AlarmTime | 1.3.6.1.4.1.53973.1.1.8.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups07AlarmTime shall equal 0. | |||||||||||||
| Nups07WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.8.1.6.3 | ||||||||||||
| Nups07AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.8.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups07AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.8.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups07AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.8.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups07ConfigLowBattTime. | |||||||||||||
| Nups07AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.8.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups07AlarmTempBad | 1.3.6.1.4.1.53973.1.1.8.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups07AlarmInputBad | 1.3.6.1.4.1.53973.1.1.8.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups07AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.8.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups07AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.8.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups07AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.8.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups07AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.8.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups07AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.8.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups07AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.8.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups07AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.8.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups07AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.8.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups07AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.8.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups07AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.8.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups07AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.8.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups07AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.8.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups07AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.8.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups07AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.8.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups07AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.8.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups07AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.8.1.6.3.22 | ||||||||||||
node · current A ups07ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups07AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.8.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups07AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.8.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups07Test | 1.3.6.1.4.1.53973.1.1.8.1.7 | ||||||||||||
| Sups07TestId | 1.3.6.1.4.1.53973.1.1.8.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups07TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups07TestResultsSummary. Tests in progress may be aborted by setting the ups07TestId variable to ups07TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups07TestNoTestsInitiated is returned. | |||||||||||||
| Sups07TestSpinLock | 1.3.6.1.4.1.53973.1.1.8.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups07TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups07TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups07TestResultsSummary */
get (upsTestSpinLock, ups07TestResultsSummary,
ups07TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups07TestResultsSummary,
ups07TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups07TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups07TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups07TestResultsSummary | 1.3.6.1.4.1.53973.1.1.8.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups07TestId to ups07TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups07TestResultsDetail | 1.3.6.1.4.1.53973.1.1.8.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups07TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups07TestStartTime | 1.3.6.1.4.1.53973.1.1.8.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups07TestResultsSummary is noTestsInitiated(6), ups07TestStartTime has the value 0. | |||||||||||||
| Sups07TestElapsedTime | 1.3.6.1.4.1.53973.1.1.8.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups07TestResultsSummary is noTestsInitiated(6), ups07TestElapsedTime has the value 0. | |||||||||||||
| Nups07WellKnownTests | 1.3.6.1.4.1.53973.1.1.8.1.7.7 | ||||||||||||
| Nups07TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.8.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups07TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.8.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups07TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.8.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups07TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.8.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups07TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.8.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups07Control | 1.3.6.1.4.1.53973.1.1.8.1.8 | ||||||||||||
| Sups07ShutdownType | 1.3.6.1.4.1.53973.1.1.8.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups07ShutdownAfterDelay and ups07RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups07ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.8.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups07ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups07ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups07ShutdownType = output and the output is already off. When read, ups07ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups07ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups07StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.8.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups07StartupAfterDelay countdown or ups07RebootWithDuration countdown in progress. When read, ups07StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups07RebootWithDuration | 1.3.6.1.4.1.53973.1.1.8.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups07ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups07RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups07Traps | 1.3.6.1.4.1.53973.1.1.8.2 | ||||||||||||
| !ups07TrapOnBattery | 1.3.6.1.4.1.53973.1.1.8.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups07TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.8.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups07TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.8.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups07AlarmOnBattery and ups07AlarmTestInProgress.
| |||||||||||||
| !ups07TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.8.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups07AlarmTestInProgress.
| |||||||||||||
| Nups07Conformance | 1.3.6.1.4.1.53973.1.1.8.3 | ||||||||||||
| Nups07Compliances | 1.3.6.1.4.1.53973.1.1.8.3.1 | ||||||||||||
| Mups07SubsetCompliance | 1.3.6.1.4.1.53973.1.1.8.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups07BasicCompliance | 1.3.6.1.4.1.53973.1.1.8.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups07FullCompliance | 1.3.6.1.4.1.53973.1.1.8.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups07Groups | 1.3.6.1.4.1.53973.1.1.8.3.2 | ||||||||||||
| Nups07SubsetGroups | 1.3.6.1.4.1.53973.1.1.8.3.2.1 | ||||||||||||
| Gups07SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.1.1 | ||||||||||||
group · current The ups07SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups07SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups07SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.1.2 | ||||||||||||
group · current The ups07SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups07SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.1.3 | ||||||||||||
group · current The ups07SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups07SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.1.4 | ||||||||||||
group · current The ups07SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups07SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.1.6 | ||||||||||||
group · current The ups07SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups07SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.1.8 | ||||||||||||
group · current The ups07SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups07BasicGroups | 1.3.6.1.4.1.53973.1.1.8.3.2.2 | ||||||||||||
| Gups07BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.1 | ||||||||||||
group · current The ups07BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups07BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.2 | ||||||||||||
group · current The ups07BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups07BasicInputGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.3 | ||||||||||||
group · current The ups07BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups07BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.4 | ||||||||||||
group · current The ups07BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups07BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.5 | ||||||||||||
group · current The ups07BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups07BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.6 | ||||||||||||
group · current The ups07BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups07BasicTestGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.7 | ||||||||||||
group · current The ups07BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups07BasicControlGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.2.8 | ||||||||||||
group · current The ups07BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups07FullGroups | 1.3.6.1.4.1.53973.1.1.8.3.2.3 | ||||||||||||
| Gups07FullIdentGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.1 | ||||||||||||
group · current The ups07FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups07FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.2 | ||||||||||||
group · current The ups07FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups07FullInputGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.3 | ||||||||||||
group · current The ups07FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups07FullOutputGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.4 | ||||||||||||
group · current The ups07FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups07FullBypassGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.5 | ||||||||||||
group · current The ups07FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups07FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.6 | ||||||||||||
group · current The ups07FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups07FullTestGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.7 | ||||||||||||
group · current The ups07FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups07FullControlGroup | 1.3.6.1.4.1.53973.1.1.8.3.2.3.8 | ||||||||||||
group · current The ups07FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule8 | 1.3.6.1.4.1.53973.1.1.9 | ||||||||||||
| Nups08Objects | 1.3.6.1.4.1.53973.1.1.9.1 | ||||||||||||
| Nups08Ident | 1.3.6.1.4.1.53973.1.1.9.1.1 | ||||||||||||
| Sups08IdentManufacturer | 1.3.6.1.4.1.53973.1.1.9.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups08IdentModel | 1.3.6.1.4.1.53973.1.1.9.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups08IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.9.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups08IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups08IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.9.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups08IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups08IdentName | 1.3.6.1.4.1.53973.1.1.9.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups08IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.9.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups08Battery | 1.3.6.1.4.1.53973.1.1.9.1.2 | ||||||||||||
| Sups08BatteryStatus | 1.3.6.1.4.1.53973.1.1.9.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups08ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups08ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups08SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.9.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups08EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.9.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups08EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.9.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups08BatteryVoltage | 1.3.6.1.4.1.53973.1.1.9.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups08BatteryCurrent | 1.3.6.1.4.1.53973.1.1.9.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups08BatteryTemperature | 1.3.6.1.4.1.53973.1.1.9.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups08Input | 1.3.6.1.4.1.53973.1.1.9.1.3 | ||||||||||||
| Sups08InputLineBads | 1.3.6.1.4.1.53973.1.1.9.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups08InputNumLines | 1.3.6.1.4.1.53973.1.1.9.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups08InputTable | 1.3.6.1.4.1.53973.1.1.9.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups08InputNumLines. | |||||||||||||
| Rups08InputEntry | 1.3.6.1.4.1.53973.1.1.9.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups08InputLineIndex | 1.3.6.1.4.1.53973.1.1.9.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups08InputFrequency | 1.3.6.1.4.1.53973.1.1.9.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups08InputVoltage | 1.3.6.1.4.1.53973.1.1.9.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups08InputCurrent | 1.3.6.1.4.1.53973.1.1.9.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups08InputTruePower | 1.3.6.1.4.1.53973.1.1.9.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups08Output | 1.3.6.1.4.1.53973.1.1.9.1.4 | ||||||||||||
| Sups08OutputSource | 1.3.6.1.4.1.53973.1.1.9.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups08OutputFrequency | 1.3.6.1.4.1.53973.1.1.9.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups08OutputNumLines | 1.3.6.1.4.1.53973.1.1.9.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups08OutputTable | 1.3.6.1.4.1.53973.1.1.9.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups08OutputNumLines. | |||||||||||||
| Rups08OutputEntry | 1.3.6.1.4.1.53973.1.1.9.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups08OutputLineIndex | 1.3.6.1.4.1.53973.1.1.9.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups08OutputVoltage | 1.3.6.1.4.1.53973.1.1.9.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups08OutputCurrent | 1.3.6.1.4.1.53973.1.1.9.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups08OutputPower | 1.3.6.1.4.1.53973.1.1.9.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups08OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.9.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups08Bypass | 1.3.6.1.4.1.53973.1.1.9.1.5 | ||||||||||||
| Sups08BypassFrequency | 1.3.6.1.4.1.53973.1.1.9.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups08BypassNumLines | 1.3.6.1.4.1.53973.1.1.9.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups08BypassTable | 1.3.6.1.4.1.53973.1.1.9.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups08BypassNumLines. | |||||||||||||
| Rups08BypassEntry | 1.3.6.1.4.1.53973.1.1.9.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups08BypassLineIndex | 1.3.6.1.4.1.53973.1.1.9.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups08BypassVoltage | 1.3.6.1.4.1.53973.1.1.9.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups08BypassCurrent | 1.3.6.1.4.1.53973.1.1.9.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups08BypassPower | 1.3.6.1.4.1.53973.1.1.9.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups08Alarm | 1.3.6.1.4.1.53973.1.1.9.1.6 | ||||||||||||
| Sups08AlarmsPresent | 1.3.6.1.4.1.53973.1.1.9.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups08AlarmTable | 1.3.6.1.4.1.53973.1.1.9.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups08AlarmId equal to 1, and increments the value of ups08AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups08AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups08AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups08AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups08AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups08AlarmsPresent. | |||||||||||||
| Rups08AlarmEntry | 1.3.6.1.4.1.53973.1.1.9.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups08AlarmId | 1.3.6.1.4.1.53973.1.1.9.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups08AlarmDescr | 1.3.6.1.4.1.53973.1.1.9.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups08AlarmTime | 1.3.6.1.4.1.53973.1.1.9.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups08AlarmTime shall equal 0. | |||||||||||||
| Nups08WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.9.1.6.3 | ||||||||||||
| Nups08AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.9.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups08AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.9.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups08AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.9.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups08ConfigLowBattTime. | |||||||||||||
| Nups08AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.9.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups08AlarmTempBad | 1.3.6.1.4.1.53973.1.1.9.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups08AlarmInputBad | 1.3.6.1.4.1.53973.1.1.9.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups08AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.9.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups08AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.9.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups08AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.9.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups08AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.9.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups08AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.9.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups08AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.9.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups08AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.9.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups08AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.9.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups08AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.9.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups08AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.9.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups08AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.9.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups08AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.9.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups08AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.9.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups08AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.9.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups08AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.9.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups08AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.9.1.6.3.22 | ||||||||||||
node · current A ups08ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups08AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.9.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups08AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.9.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups08Test | 1.3.6.1.4.1.53973.1.1.9.1.7 | ||||||||||||
| Sups08TestId | 1.3.6.1.4.1.53973.1.1.9.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups08TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups08TestResultsSummary. Tests in progress may be aborted by setting the ups08TestId variable to ups08TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups08TestNoTestsInitiated is returned. | |||||||||||||
| Sups08TestSpinLock | 1.3.6.1.4.1.53973.1.1.9.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups08TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups08TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups08TestResultsSummary */
get (upsTestSpinLock, ups08TestResultsSummary,
ups08TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups08TestResultsSummary,
ups08TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups08TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups08TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups08TestResultsSummary | 1.3.6.1.4.1.53973.1.1.9.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups08TestId to ups08TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups08TestResultsDetail | 1.3.6.1.4.1.53973.1.1.9.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups08TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups08TestStartTime | 1.3.6.1.4.1.53973.1.1.9.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups08TestResultsSummary is noTestsInitiated(6), ups08TestStartTime has the value 0. | |||||||||||||
| Sups08TestElapsedTime | 1.3.6.1.4.1.53973.1.1.9.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups08TestResultsSummary is noTestsInitiated(6), ups08TestElapsedTime has the value 0. | |||||||||||||
| Nups08WellKnownTests | 1.3.6.1.4.1.53973.1.1.9.1.7.7 | ||||||||||||
| Nups08TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.9.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups08TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.9.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups08TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.9.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups08TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.9.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups08TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.9.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups08Control | 1.3.6.1.4.1.53973.1.1.9.1.8 | ||||||||||||
| Sups08ShutdownType | 1.3.6.1.4.1.53973.1.1.9.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups08ShutdownAfterDelay and ups08RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups08ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.9.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups08ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups08ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups08ShutdownType = output and the output is already off. When read, ups08ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups08ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups08StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.9.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups08StartupAfterDelay countdown or ups08RebootWithDuration countdown in progress. When read, ups08StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups08RebootWithDuration | 1.3.6.1.4.1.53973.1.1.9.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups08ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups08RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups08Traps | 1.3.6.1.4.1.53973.1.1.9.2 | ||||||||||||
| !ups08TrapOnBattery | 1.3.6.1.4.1.53973.1.1.9.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups08TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.9.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups08TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.9.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups08AlarmOnBattery and ups08AlarmTestInProgress.
| |||||||||||||
| !ups08TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.9.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups08AlarmTestInProgress.
| |||||||||||||
| Nups08Conformance | 1.3.6.1.4.1.53973.1.1.9.3 | ||||||||||||
| Nups08Compliances | 1.3.6.1.4.1.53973.1.1.9.3.1 | ||||||||||||
| Mups08SubsetCompliance | 1.3.6.1.4.1.53973.1.1.9.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups08BasicCompliance | 1.3.6.1.4.1.53973.1.1.9.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups08FullCompliance | 1.3.6.1.4.1.53973.1.1.9.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups08Groups | 1.3.6.1.4.1.53973.1.1.9.3.2 | ||||||||||||
| Nups08SubsetGroups | 1.3.6.1.4.1.53973.1.1.9.3.2.1 | ||||||||||||
| Gups08SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.1.1 | ||||||||||||
group · current The ups08SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups08SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups08SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.1.2 | ||||||||||||
group · current The ups08SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups08SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.1.3 | ||||||||||||
group · current The ups08SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups08SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.1.4 | ||||||||||||
group · current The ups08SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups08SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.1.6 | ||||||||||||
group · current The ups08SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups08SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.1.8 | ||||||||||||
group · current The ups08SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups08BasicGroups | 1.3.6.1.4.1.53973.1.1.9.3.2.2 | ||||||||||||
| Gups08BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.1 | ||||||||||||
group · current The ups08BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups08BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.2 | ||||||||||||
group · current The ups08BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups08BasicInputGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.3 | ||||||||||||
group · current The ups08BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups08BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.4 | ||||||||||||
group · current The ups08BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups08BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.5 | ||||||||||||
group · current The ups08BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups08BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.6 | ||||||||||||
group · current The ups08BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups08BasicTestGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.7 | ||||||||||||
group · current The ups08BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups08BasicControlGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.2.8 | ||||||||||||
group · current The ups08BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups08FullGroups | 1.3.6.1.4.1.53973.1.1.9.3.2.3 | ||||||||||||
| Gups08FullIdentGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.1 | ||||||||||||
group · current The ups08FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups08FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.2 | ||||||||||||
group · current The ups08FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups08FullInputGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.3 | ||||||||||||
group · current The ups08FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups08FullOutputGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.4 | ||||||||||||
group · current The ups08FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups08FullBypassGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.5 | ||||||||||||
group · current The ups08FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups08FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.6 | ||||||||||||
group · current The ups08FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups08FullTestGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.7 | ||||||||||||
group · current The ups08FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups08FullControlGroup | 1.3.6.1.4.1.53973.1.1.9.3.2.3.8 | ||||||||||||
group · current The ups08FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule9 | 1.3.6.1.4.1.53973.1.1.10 | ||||||||||||
| Nups09Objects | 1.3.6.1.4.1.53973.1.1.10.1 | ||||||||||||
| Nups09Ident | 1.3.6.1.4.1.53973.1.1.10.1.1 | ||||||||||||
| Sups09IdentManufacturer | 1.3.6.1.4.1.53973.1.1.10.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups09IdentModel | 1.3.6.1.4.1.53973.1.1.10.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups09IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.10.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups09IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups09IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.10.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups09IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups09IdentName | 1.3.6.1.4.1.53973.1.1.10.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups09IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.10.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups09Battery | 1.3.6.1.4.1.53973.1.1.10.1.2 | ||||||||||||
| Sups09BatteryStatus | 1.3.6.1.4.1.53973.1.1.10.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups09ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups09ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups09SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.10.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups09EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.10.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups09EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.10.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups09BatteryVoltage | 1.3.6.1.4.1.53973.1.1.10.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups09BatteryCurrent | 1.3.6.1.4.1.53973.1.1.10.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups09BatteryTemperature | 1.3.6.1.4.1.53973.1.1.10.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups09Input | 1.3.6.1.4.1.53973.1.1.10.1.3 | ||||||||||||
| Sups09InputLineBads | 1.3.6.1.4.1.53973.1.1.10.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups09InputNumLines | 1.3.6.1.4.1.53973.1.1.10.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups09InputTable | 1.3.6.1.4.1.53973.1.1.10.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups09InputNumLines. | |||||||||||||
| Rups09InputEntry | 1.3.6.1.4.1.53973.1.1.10.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups09InputLineIndex | 1.3.6.1.4.1.53973.1.1.10.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups09InputFrequency | 1.3.6.1.4.1.53973.1.1.10.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups09InputVoltage | 1.3.6.1.4.1.53973.1.1.10.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups09InputCurrent | 1.3.6.1.4.1.53973.1.1.10.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups09InputTruePower | 1.3.6.1.4.1.53973.1.1.10.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups09Output | 1.3.6.1.4.1.53973.1.1.10.1.4 | ||||||||||||
| Sups09OutputSource | 1.3.6.1.4.1.53973.1.1.10.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups09OutputFrequency | 1.3.6.1.4.1.53973.1.1.10.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups09OutputNumLines | 1.3.6.1.4.1.53973.1.1.10.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups09OutputTable | 1.3.6.1.4.1.53973.1.1.10.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups09OutputNumLines. | |||||||||||||
| Rups09OutputEntry | 1.3.6.1.4.1.53973.1.1.10.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups09OutputLineIndex | 1.3.6.1.4.1.53973.1.1.10.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups09OutputVoltage | 1.3.6.1.4.1.53973.1.1.10.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups09OutputCurrent | 1.3.6.1.4.1.53973.1.1.10.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups09OutputPower | 1.3.6.1.4.1.53973.1.1.10.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups09OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.10.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups09Bypass | 1.3.6.1.4.1.53973.1.1.10.1.5 | ||||||||||||
| Sups09BypassFrequency | 1.3.6.1.4.1.53973.1.1.10.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups09BypassNumLines | 1.3.6.1.4.1.53973.1.1.10.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups09BypassTable | 1.3.6.1.4.1.53973.1.1.10.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups09BypassNumLines. | |||||||||||||
| Rups09BypassEntry | 1.3.6.1.4.1.53973.1.1.10.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups09BypassLineIndex | 1.3.6.1.4.1.53973.1.1.10.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups09BypassVoltage | 1.3.6.1.4.1.53973.1.1.10.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups09BypassCurrent | 1.3.6.1.4.1.53973.1.1.10.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups09BypassPower | 1.3.6.1.4.1.53973.1.1.10.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups09Alarm | 1.3.6.1.4.1.53973.1.1.10.1.6 | ||||||||||||
| Sups09AlarmsPresent | 1.3.6.1.4.1.53973.1.1.10.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups09AlarmTable | 1.3.6.1.4.1.53973.1.1.10.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups09AlarmId equal to 1, and increments the value of ups09AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups09AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups09AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups09AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups09AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups09AlarmsPresent. | |||||||||||||
| Rups09AlarmEntry | 1.3.6.1.4.1.53973.1.1.10.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups09AlarmId | 1.3.6.1.4.1.53973.1.1.10.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups09AlarmDescr | 1.3.6.1.4.1.53973.1.1.10.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups09AlarmTime | 1.3.6.1.4.1.53973.1.1.10.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups09AlarmTime shall equal 0. | |||||||||||||
| Nups09WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.10.1.6.3 | ||||||||||||
| Nups09AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.10.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups09AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.10.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups09AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.10.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups09ConfigLowBattTime. | |||||||||||||
| Nups09AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.10.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups09AlarmTempBad | 1.3.6.1.4.1.53973.1.1.10.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups09AlarmInputBad | 1.3.6.1.4.1.53973.1.1.10.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups09AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.10.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups09AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.10.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups09AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.10.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups09AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.10.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups09AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.10.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups09AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.10.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups09AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.10.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups09AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.10.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups09AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.10.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups09AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.10.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups09AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.10.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups09AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.10.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups09AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.10.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups09AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.10.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups09AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.10.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups09AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.10.1.6.3.22 | ||||||||||||
node · current A ups09ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups09AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.10.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups09AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.10.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups09Test | 1.3.6.1.4.1.53973.1.1.10.1.7 | ||||||||||||
| Sups09TestId | 1.3.6.1.4.1.53973.1.1.10.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups09TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups09TestResultsSummary. Tests in progress may be aborted by setting the ups09TestId variable to ups09TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups09TestNoTestsInitiated is returned. | |||||||||||||
| Sups09TestSpinLock | 1.3.6.1.4.1.53973.1.1.10.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups09TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups09TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups09TestResultsSummary */
get (upsTestSpinLock, ups09TestResultsSummary,
ups09TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups09TestResultsSummary,
ups09TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups09TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups09TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups09TestResultsSummary | 1.3.6.1.4.1.53973.1.1.10.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups09TestId to ups09TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups09TestResultsDetail | 1.3.6.1.4.1.53973.1.1.10.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups09TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups09TestStartTime | 1.3.6.1.4.1.53973.1.1.10.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups09TestResultsSummary is noTestsInitiated(6), ups09TestStartTime has the value 0. | |||||||||||||
| Sups09TestElapsedTime | 1.3.6.1.4.1.53973.1.1.10.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups09TestResultsSummary is noTestsInitiated(6), ups09TestElapsedTime has the value 0. | |||||||||||||
| Nups09WellKnownTests | 1.3.6.1.4.1.53973.1.1.10.1.7.7 | ||||||||||||
| Nups09TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.10.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups09TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.10.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups09TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.10.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups09TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.10.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups09TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.10.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups09Control | 1.3.6.1.4.1.53973.1.1.10.1.8 | ||||||||||||
| Sups09ShutdownType | 1.3.6.1.4.1.53973.1.1.10.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups09ShutdownAfterDelay and ups09RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups09ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.10.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups09ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups09ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups09ShutdownType = output and the output is already off. When read, ups09ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups09ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups09StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.10.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups09StartupAfterDelay countdown or ups09RebootWithDuration countdown in progress. When read, ups09StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups09RebootWithDuration | 1.3.6.1.4.1.53973.1.1.10.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups09ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups09RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups09Traps | 1.3.6.1.4.1.53973.1.1.10.2 | ||||||||||||
| !ups09TrapOnBattery | 1.3.6.1.4.1.53973.1.1.10.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups09TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.10.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups09TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.10.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups09AlarmOnBattery and ups09AlarmTestInProgress.
| |||||||||||||
| !ups09TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.10.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups09AlarmTestInProgress.
| |||||||||||||
| Nups09Conformance | 1.3.6.1.4.1.53973.1.1.10.3 | ||||||||||||
| Nups09Compliances | 1.3.6.1.4.1.53973.1.1.10.3.1 | ||||||||||||
| Mups09SubsetCompliance | 1.3.6.1.4.1.53973.1.1.10.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups09BasicCompliance | 1.3.6.1.4.1.53973.1.1.10.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups09FullCompliance | 1.3.6.1.4.1.53973.1.1.10.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups09Groups | 1.3.6.1.4.1.53973.1.1.10.3.2 | ||||||||||||
| Nups09SubsetGroups | 1.3.6.1.4.1.53973.1.1.10.3.2.1 | ||||||||||||
| Gups09SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.1.1 | ||||||||||||
group · current The ups09SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups09SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups09SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.1.2 | ||||||||||||
group · current The ups09SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups09SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.1.3 | ||||||||||||
group · current The ups09SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups09SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.1.4 | ||||||||||||
group · current The ups09SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups09SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.1.6 | ||||||||||||
group · current The ups09SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups09SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.1.8 | ||||||||||||
group · current The ups09SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups09BasicGroups | 1.3.6.1.4.1.53973.1.1.10.3.2.2 | ||||||||||||
| Gups09BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.1 | ||||||||||||
group · current The ups09BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups09BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.2 | ||||||||||||
group · current The ups09BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups09BasicInputGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.3 | ||||||||||||
group · current The ups09BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups09BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.4 | ||||||||||||
group · current The ups09BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups09BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.5 | ||||||||||||
group · current The ups09BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups09BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.6 | ||||||||||||
group · current The ups09BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups09BasicTestGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.7 | ||||||||||||
group · current The ups09BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups09BasicControlGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.2.8 | ||||||||||||
group · current The ups09BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups09FullGroups | 1.3.6.1.4.1.53973.1.1.10.3.2.3 | ||||||||||||
| Gups09FullIdentGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.1 | ||||||||||||
group · current The ups09FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups09FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.2 | ||||||||||||
group · current The ups09FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups09FullInputGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.3 | ||||||||||||
group · current The ups09FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups09FullOutputGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.4 | ||||||||||||
group · current The ups09FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups09FullBypassGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.5 | ||||||||||||
group · current The ups09FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups09FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.6 | ||||||||||||
group · current The ups09FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups09FullTestGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.7 | ||||||||||||
group · current The ups09FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups09FullControlGroup | 1.3.6.1.4.1.53973.1.1.10.3.2.3.8 | ||||||||||||
group · current The ups09FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule10 | 1.3.6.1.4.1.53973.1.1.11 | ||||||||||||
| Nups10Objects | 1.3.6.1.4.1.53973.1.1.11.1 | ||||||||||||
| Nups10Ident | 1.3.6.1.4.1.53973.1.1.11.1.1 | ||||||||||||
| Sups10IdentManufacturer | 1.3.6.1.4.1.53973.1.1.11.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups10IdentModel | 1.3.6.1.4.1.53973.1.1.11.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups10IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.11.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups10IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups10IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.11.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups10IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups10IdentName | 1.3.6.1.4.1.53973.1.1.11.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups10IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.11.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups10Battery | 1.3.6.1.4.1.53973.1.1.11.1.2 | ||||||||||||
| Sups10BatteryStatus | 1.3.6.1.4.1.53973.1.1.11.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups10ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups10ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups10SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.11.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups10EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.11.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups10EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.11.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups10BatteryVoltage | 1.3.6.1.4.1.53973.1.1.11.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups10BatteryCurrent | 1.3.6.1.4.1.53973.1.1.11.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups10BatteryTemperature | 1.3.6.1.4.1.53973.1.1.11.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups10Input | 1.3.6.1.4.1.53973.1.1.11.1.3 | ||||||||||||
| Sups10InputLineBads | 1.3.6.1.4.1.53973.1.1.11.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups10InputNumLines | 1.3.6.1.4.1.53973.1.1.11.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups10InputTable | 1.3.6.1.4.1.53973.1.1.11.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups10InputNumLines. | |||||||||||||
| Rups10InputEntry | 1.3.6.1.4.1.53973.1.1.11.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups10InputLineIndex | 1.3.6.1.4.1.53973.1.1.11.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups10InputFrequency | 1.3.6.1.4.1.53973.1.1.11.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups10InputVoltage | 1.3.6.1.4.1.53973.1.1.11.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups10InputCurrent | 1.3.6.1.4.1.53973.1.1.11.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups10InputTruePower | 1.3.6.1.4.1.53973.1.1.11.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups10Output | 1.3.6.1.4.1.53973.1.1.11.1.4 | ||||||||||||
| Sups10OutputSource | 1.3.6.1.4.1.53973.1.1.11.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups10OutputFrequency | 1.3.6.1.4.1.53973.1.1.11.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups10OutputNumLines | 1.3.6.1.4.1.53973.1.1.11.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups10OutputTable | 1.3.6.1.4.1.53973.1.1.11.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups10OutputNumLines. | |||||||||||||
| Rups10OutputEntry | 1.3.6.1.4.1.53973.1.1.11.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups10OutputLineIndex | 1.3.6.1.4.1.53973.1.1.11.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups10OutputVoltage | 1.3.6.1.4.1.53973.1.1.11.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups10OutputCurrent | 1.3.6.1.4.1.53973.1.1.11.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups10OutputPower | 1.3.6.1.4.1.53973.1.1.11.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups10OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.11.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups10Bypass | 1.3.6.1.4.1.53973.1.1.11.1.5 | ||||||||||||
| Sups10BypassFrequency | 1.3.6.1.4.1.53973.1.1.11.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups10BypassNumLines | 1.3.6.1.4.1.53973.1.1.11.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups10BypassTable | 1.3.6.1.4.1.53973.1.1.11.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups10BypassNumLines. | |||||||||||||
| Rups10BypassEntry | 1.3.6.1.4.1.53973.1.1.11.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups10BypassLineIndex | 1.3.6.1.4.1.53973.1.1.11.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups10BypassVoltage | 1.3.6.1.4.1.53973.1.1.11.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups10BypassCurrent | 1.3.6.1.4.1.53973.1.1.11.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups10BypassPower | 1.3.6.1.4.1.53973.1.1.11.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups10Alarm | 1.3.6.1.4.1.53973.1.1.11.1.6 | ||||||||||||
| Sups10AlarmsPresent | 1.3.6.1.4.1.53973.1.1.11.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups10AlarmTable | 1.3.6.1.4.1.53973.1.1.11.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups10AlarmId equal to 1, and increments the value of ups10AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups10AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups10AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups10AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups10AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups10AlarmsPresent. | |||||||||||||
| Rups10AlarmEntry | 1.3.6.1.4.1.53973.1.1.11.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups10AlarmId | 1.3.6.1.4.1.53973.1.1.11.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups10AlarmDescr | 1.3.6.1.4.1.53973.1.1.11.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups10AlarmTime | 1.3.6.1.4.1.53973.1.1.11.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups10AlarmTime shall equal 0. | |||||||||||||
| Nups10WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.11.1.6.3 | ||||||||||||
| Nups10AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.11.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups10AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.11.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups10AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.11.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups10ConfigLowBattTime. | |||||||||||||
| Nups10AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.11.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups10AlarmTempBad | 1.3.6.1.4.1.53973.1.1.11.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups10AlarmInputBad | 1.3.6.1.4.1.53973.1.1.11.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups10AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.11.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups10AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.11.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups10AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.11.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups10AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.11.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups10AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.11.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups10AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.11.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups10AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.11.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups10AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.11.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups10AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.11.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups10AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.11.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups10AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.11.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups10AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.11.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups10AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.11.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups10AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.11.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups10AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.11.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups10AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.11.1.6.3.22 | ||||||||||||
node · current A ups10ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups10AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.11.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups10AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.11.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups10Test | 1.3.6.1.4.1.53973.1.1.11.1.7 | ||||||||||||
| Sups10TestId | 1.3.6.1.4.1.53973.1.1.11.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups10TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups10TestResultsSummary. Tests in progress may be aborted by setting the ups10TestId variable to ups10TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups10TestNoTestsInitiated is returned. | |||||||||||||
| Sups10TestSpinLock | 1.3.6.1.4.1.53973.1.1.11.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups10TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups10TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups10TestResultsSummary */
get (upsTestSpinLock, ups10TestResultsSummary,
ups10TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups10TestResultsSummary,
ups10TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups10TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups10TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups10TestResultsSummary | 1.3.6.1.4.1.53973.1.1.11.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups10TestId to ups10TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups10TestResultsDetail | 1.3.6.1.4.1.53973.1.1.11.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups10TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups10TestStartTime | 1.3.6.1.4.1.53973.1.1.11.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups10TestResultsSummary is noTestsInitiated(6), ups10TestStartTime has the value 0. | |||||||||||||
| Sups10TestElapsedTime | 1.3.6.1.4.1.53973.1.1.11.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups10TestResultsSummary is noTestsInitiated(6), ups10TestElapsedTime has the value 0. | |||||||||||||
| Nups10WellKnownTests | 1.3.6.1.4.1.53973.1.1.11.1.7.7 | ||||||||||||
| Nups10TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.11.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups10TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.11.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups10TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.11.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups10TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.11.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups10TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.11.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups10Control | 1.3.6.1.4.1.53973.1.1.11.1.8 | ||||||||||||
| Sups10ShutdownType | 1.3.6.1.4.1.53973.1.1.11.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups10ShutdownAfterDelay and ups10RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups10ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.11.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups10ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups10ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups10ShutdownType = output and the output is already off. When read, ups10ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups10ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups10StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.11.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups10StartupAfterDelay countdown or ups10RebootWithDuration countdown in progress. When read, ups10StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups10RebootWithDuration | 1.3.6.1.4.1.53973.1.1.11.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups10ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups10RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups10Traps | 1.3.6.1.4.1.53973.1.1.11.2 | ||||||||||||
| !ups10TrapOnBattery | 1.3.6.1.4.1.53973.1.1.11.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups10TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.11.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups10TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.11.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups10AlarmOnBattery and ups10AlarmTestInProgress.
| |||||||||||||
| !ups10TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.11.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups10AlarmTestInProgress.
| |||||||||||||
| Nups10Conformance | 1.3.6.1.4.1.53973.1.1.11.3 | ||||||||||||
| Nups10Compliances | 1.3.6.1.4.1.53973.1.1.11.3.1 | ||||||||||||
| Mups10SubsetCompliance | 1.3.6.1.4.1.53973.1.1.11.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups10BasicCompliance | 1.3.6.1.4.1.53973.1.1.11.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups10FullCompliance | 1.3.6.1.4.1.53973.1.1.11.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups10Groups | 1.3.6.1.4.1.53973.1.1.11.3.2 | ||||||||||||
| Nups10SubsetGroups | 1.3.6.1.4.1.53973.1.1.11.3.2.1 | ||||||||||||
| Gups10SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.1.1 | ||||||||||||
group · current The ups10SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups10SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups10SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.1.2 | ||||||||||||
group · current The ups10SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups10SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.1.3 | ||||||||||||
group · current The ups10SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups10SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.1.4 | ||||||||||||
group · current The ups10SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups10SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.1.6 | ||||||||||||
group · current The ups10SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups10SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.1.8 | ||||||||||||
group · current The ups10SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups10BasicGroups | 1.3.6.1.4.1.53973.1.1.11.3.2.2 | ||||||||||||
| Gups10BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.1 | ||||||||||||
group · current The ups10BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups10BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.2 | ||||||||||||
group · current The ups10BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups10BasicInputGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.3 | ||||||||||||
group · current The ups10BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups10BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.4 | ||||||||||||
group · current The ups10BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups10BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.5 | ||||||||||||
group · current The ups10BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups10BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.6 | ||||||||||||
group · current The ups10BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups10BasicTestGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.7 | ||||||||||||
group · current The ups10BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups10BasicControlGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.2.8 | ||||||||||||
group · current The ups10BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups10FullGroups | 1.3.6.1.4.1.53973.1.1.11.3.2.3 | ||||||||||||
| Gups10FullIdentGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.1 | ||||||||||||
group · current The ups10FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups10FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.2 | ||||||||||||
group · current The ups10FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups10FullInputGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.3 | ||||||||||||
group · current The ups10FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups10FullOutputGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.4 | ||||||||||||
group · current The ups10FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups10FullBypassGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.5 | ||||||||||||
group · current The ups10FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups10FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.6 | ||||||||||||
group · current The ups10FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups10FullTestGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.7 | ||||||||||||
group · current The ups10FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups10FullControlGroup | 1.3.6.1.4.1.53973.1.1.11.3.2.3.8 | ||||||||||||
group · current The ups10FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule11 | 1.3.6.1.4.1.53973.1.1.12 | ||||||||||||
| Nups11Objects | 1.3.6.1.4.1.53973.1.1.12.1 | ||||||||||||
| Nups11Ident | 1.3.6.1.4.1.53973.1.1.12.1.1 | ||||||||||||
| Sups11IdentManufacturer | 1.3.6.1.4.1.53973.1.1.12.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups11IdentModel | 1.3.6.1.4.1.53973.1.1.12.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups11IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.12.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups11IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups11IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.12.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups11IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups11IdentName | 1.3.6.1.4.1.53973.1.1.12.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups11IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.12.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups11Battery | 1.3.6.1.4.1.53973.1.1.12.1.2 | ||||||||||||
| Sups11BatteryStatus | 1.3.6.1.4.1.53973.1.1.12.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups11ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups11ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups11SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.12.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups11EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.12.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups11EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.12.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups11BatteryVoltage | 1.3.6.1.4.1.53973.1.1.12.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups11BatteryCurrent | 1.3.6.1.4.1.53973.1.1.12.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups11BatteryTemperature | 1.3.6.1.4.1.53973.1.1.12.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups11Input | 1.3.6.1.4.1.53973.1.1.12.1.3 | ||||||||||||
| Sups11InputLineBads | 1.3.6.1.4.1.53973.1.1.12.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups11InputNumLines | 1.3.6.1.4.1.53973.1.1.12.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups11InputTable | 1.3.6.1.4.1.53973.1.1.12.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups11InputNumLines. | |||||||||||||
| Rups11InputEntry | 1.3.6.1.4.1.53973.1.1.12.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups11InputLineIndex | 1.3.6.1.4.1.53973.1.1.12.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups11InputFrequency | 1.3.6.1.4.1.53973.1.1.12.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups11InputVoltage | 1.3.6.1.4.1.53973.1.1.12.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups11InputCurrent | 1.3.6.1.4.1.53973.1.1.12.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups11InputTruePower | 1.3.6.1.4.1.53973.1.1.12.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups11Output | 1.3.6.1.4.1.53973.1.1.12.1.4 | ||||||||||||
| Sups11OutputSource | 1.3.6.1.4.1.53973.1.1.12.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups11OutputFrequency | 1.3.6.1.4.1.53973.1.1.12.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups11OutputNumLines | 1.3.6.1.4.1.53973.1.1.12.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups11OutputTable | 1.3.6.1.4.1.53973.1.1.12.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups11OutputNumLines. | |||||||||||||
| Rups11OutputEntry | 1.3.6.1.4.1.53973.1.1.12.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups11OutputLineIndex | 1.3.6.1.4.1.53973.1.1.12.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups11OutputVoltage | 1.3.6.1.4.1.53973.1.1.12.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups11OutputCurrent | 1.3.6.1.4.1.53973.1.1.12.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups11OutputPower | 1.3.6.1.4.1.53973.1.1.12.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups11OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.12.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups11Bypass | 1.3.6.1.4.1.53973.1.1.12.1.5 | ||||||||||||
| Sups11BypassFrequency | 1.3.6.1.4.1.53973.1.1.12.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups11BypassNumLines | 1.3.6.1.4.1.53973.1.1.12.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups11BypassTable | 1.3.6.1.4.1.53973.1.1.12.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups11BypassNumLines. | |||||||||||||
| Rups11BypassEntry | 1.3.6.1.4.1.53973.1.1.12.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups11BypassLineIndex | 1.3.6.1.4.1.53973.1.1.12.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups11BypassVoltage | 1.3.6.1.4.1.53973.1.1.12.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups11BypassCurrent | 1.3.6.1.4.1.53973.1.1.12.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups11BypassPower | 1.3.6.1.4.1.53973.1.1.12.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups11Alarm | 1.3.6.1.4.1.53973.1.1.12.1.6 | ||||||||||||
| Sups11AlarmsPresent | 1.3.6.1.4.1.53973.1.1.12.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups11AlarmTable | 1.3.6.1.4.1.53973.1.1.12.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups11AlarmId equal to 1, and increments the value of ups11AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups11AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups11AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups11AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups11AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups11AlarmsPresent. | |||||||||||||
| Rups11AlarmEntry | 1.3.6.1.4.1.53973.1.1.12.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups11AlarmId | 1.3.6.1.4.1.53973.1.1.12.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups11AlarmDescr | 1.3.6.1.4.1.53973.1.1.12.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups11AlarmTime | 1.3.6.1.4.1.53973.1.1.12.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups11AlarmTime shall equal 0. | |||||||||||||
| Nups11WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.12.1.6.3 | ||||||||||||
| Nups11AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.12.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups11AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.12.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups11AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.12.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups11ConfigLowBattTime. | |||||||||||||
| Nups11AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.12.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups11AlarmTempBad | 1.3.6.1.4.1.53973.1.1.12.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups11AlarmInputBad | 1.3.6.1.4.1.53973.1.1.12.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups11AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.12.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups11AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.12.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups11AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.12.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups11AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.12.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups11AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.12.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups11AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.12.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups11AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.12.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups11AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.12.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups11AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.12.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups11AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.12.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups11AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.12.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups11AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.12.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups11AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.12.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups11AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.12.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups11AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.12.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups11AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.12.1.6.3.22 | ||||||||||||
node · current A ups11ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups11AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.12.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups11AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.12.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups11Test | 1.3.6.1.4.1.53973.1.1.12.1.7 | ||||||||||||
| Sups11TestId | 1.3.6.1.4.1.53973.1.1.12.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups11TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups11TestResultsSummary. Tests in progress may be aborted by setting the ups11TestId variable to ups11TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups11TestNoTestsInitiated is returned. | |||||||||||||
| Sups11TestSpinLock | 1.3.6.1.4.1.53973.1.1.12.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups11TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups11TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups11TestResultsSummary */
get (upsTestSpinLock, ups11TestResultsSummary,
ups11TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups11TestResultsSummary,
ups11TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups11TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups11TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups11TestResultsSummary | 1.3.6.1.4.1.53973.1.1.12.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups11TestId to ups11TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups11TestResultsDetail | 1.3.6.1.4.1.53973.1.1.12.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups11TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups11TestStartTime | 1.3.6.1.4.1.53973.1.1.12.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups11TestResultsSummary is noTestsInitiated(6), ups11TestStartTime has the value 0. | |||||||||||||
| Sups11TestElapsedTime | 1.3.6.1.4.1.53973.1.1.12.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups11TestResultsSummary is noTestsInitiated(6), ups11TestElapsedTime has the value 0. | |||||||||||||
| Nups11WellKnownTests | 1.3.6.1.4.1.53973.1.1.12.1.7.7 | ||||||||||||
| Nups11TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.12.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups11TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.12.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups11TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.12.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups11TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.12.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups11TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.12.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups11Control | 1.3.6.1.4.1.53973.1.1.12.1.8 | ||||||||||||
| Sups11ShutdownType | 1.3.6.1.4.1.53973.1.1.12.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups11ShutdownAfterDelay and ups11RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups11ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.12.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups11ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups11ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups11ShutdownType = output and the output is already off. When read, ups11ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups11ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups11StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.12.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups11StartupAfterDelay countdown or ups11RebootWithDuration countdown in progress. When read, ups11StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups11RebootWithDuration | 1.3.6.1.4.1.53973.1.1.12.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups11ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups11RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups11Traps | 1.3.6.1.4.1.53973.1.1.12.2 | ||||||||||||
| !ups11TrapOnBattery | 1.3.6.1.4.1.53973.1.1.12.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups11TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.12.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups11TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.12.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups11AlarmOnBattery and ups11AlarmTestInProgress.
| |||||||||||||
| !ups11TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.12.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups11AlarmTestInProgress.
| |||||||||||||
| Nups11Conformance | 1.3.6.1.4.1.53973.1.1.12.3 | ||||||||||||
| Nups11Compliances | 1.3.6.1.4.1.53973.1.1.12.3.1 | ||||||||||||
| Mups11SubsetCompliance | 1.3.6.1.4.1.53973.1.1.12.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups11BasicCompliance | 1.3.6.1.4.1.53973.1.1.12.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups11FullCompliance | 1.3.6.1.4.1.53973.1.1.12.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups11Groups | 1.3.6.1.4.1.53973.1.1.12.3.2 | ||||||||||||
| Nups11SubsetGroups | 1.3.6.1.4.1.53973.1.1.12.3.2.1 | ||||||||||||
| Gups11SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.1.1 | ||||||||||||
group · current The ups11SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups11SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups11SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.1.2 | ||||||||||||
group · current The ups11SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups11SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.1.3 | ||||||||||||
group · current The ups11SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups11SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.1.4 | ||||||||||||
group · current The ups11SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups11SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.1.6 | ||||||||||||
group · current The ups11SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups11SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.1.8 | ||||||||||||
group · current The ups11SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups11BasicGroups | 1.3.6.1.4.1.53973.1.1.12.3.2.2 | ||||||||||||
| Gups11BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.1 | ||||||||||||
group · current The ups11BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups11BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.2 | ||||||||||||
group · current The ups11BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups11BasicInputGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.3 | ||||||||||||
group · current The ups11BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups11BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.4 | ||||||||||||
group · current The ups11BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups11BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.5 | ||||||||||||
group · current The ups11BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups11BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.6 | ||||||||||||
group · current The ups11BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups11BasicTestGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.7 | ||||||||||||
group · current The ups11BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups11BasicControlGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.2.8 | ||||||||||||
group · current The ups11BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups11FullGroups | 1.3.6.1.4.1.53973.1.1.12.3.2.3 | ||||||||||||
| Gups11FullIdentGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.1 | ||||||||||||
group · current The ups11FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups11FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.2 | ||||||||||||
group · current The ups11FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups11FullInputGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.3 | ||||||||||||
group · current The ups11FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups11FullOutputGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.4 | ||||||||||||
group · current The ups11FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups11FullBypassGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.5 | ||||||||||||
group · current The ups11FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups11FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.6 | ||||||||||||
group · current The ups11FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups11FullTestGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.7 | ||||||||||||
group · current The ups11FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups11FullControlGroup | 1.3.6.1.4.1.53973.1.1.12.3.2.3.8 | ||||||||||||
group · current The ups11FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule12 | 1.3.6.1.4.1.53973.1.1.13 | ||||||||||||
| Nups12Objects | 1.3.6.1.4.1.53973.1.1.13.1 | ||||||||||||
| Nups12Ident | 1.3.6.1.4.1.53973.1.1.13.1.1 | ||||||||||||
| Sups12IdentManufacturer | 1.3.6.1.4.1.53973.1.1.13.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups12IdentModel | 1.3.6.1.4.1.53973.1.1.13.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups12IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.13.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups12IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups12IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.13.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups12IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups12IdentName | 1.3.6.1.4.1.53973.1.1.13.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups12IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.13.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups12Battery | 1.3.6.1.4.1.53973.1.1.13.1.2 | ||||||||||||
| Sups12BatteryStatus | 1.3.6.1.4.1.53973.1.1.13.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups12ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups12ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups12SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.13.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups12EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.13.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups12EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.13.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups12BatteryVoltage | 1.3.6.1.4.1.53973.1.1.13.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups12BatteryCurrent | 1.3.6.1.4.1.53973.1.1.13.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups12BatteryTemperature | 1.3.6.1.4.1.53973.1.1.13.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups12Input | 1.3.6.1.4.1.53973.1.1.13.1.3 | ||||||||||||
| Sups12InputLineBads | 1.3.6.1.4.1.53973.1.1.13.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups12InputNumLines | 1.3.6.1.4.1.53973.1.1.13.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups12InputTable | 1.3.6.1.4.1.53973.1.1.13.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups12InputNumLines. | |||||||||||||
| Rups12InputEntry | 1.3.6.1.4.1.53973.1.1.13.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups12InputLineIndex | 1.3.6.1.4.1.53973.1.1.13.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups12InputFrequency | 1.3.6.1.4.1.53973.1.1.13.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups12InputVoltage | 1.3.6.1.4.1.53973.1.1.13.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups12InputCurrent | 1.3.6.1.4.1.53973.1.1.13.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups12InputTruePower | 1.3.6.1.4.1.53973.1.1.13.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups12Output | 1.3.6.1.4.1.53973.1.1.13.1.4 | ||||||||||||
| Sups12OutputSource | 1.3.6.1.4.1.53973.1.1.13.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups12OutputFrequency | 1.3.6.1.4.1.53973.1.1.13.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups12OutputNumLines | 1.3.6.1.4.1.53973.1.1.13.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups12OutputTable | 1.3.6.1.4.1.53973.1.1.13.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups12OutputNumLines. | |||||||||||||
| Rups12OutputEntry | 1.3.6.1.4.1.53973.1.1.13.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups12OutputLineIndex | 1.3.6.1.4.1.53973.1.1.13.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups12OutputVoltage | 1.3.6.1.4.1.53973.1.1.13.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups12OutputCurrent | 1.3.6.1.4.1.53973.1.1.13.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups12OutputPower | 1.3.6.1.4.1.53973.1.1.13.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups12OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.13.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups12Bypass | 1.3.6.1.4.1.53973.1.1.13.1.5 | ||||||||||||
| Sups12BypassFrequency | 1.3.6.1.4.1.53973.1.1.13.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups12BypassNumLines | 1.3.6.1.4.1.53973.1.1.13.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups12BypassTable | 1.3.6.1.4.1.53973.1.1.13.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups12BypassNumLines. | |||||||||||||
| Rups12BypassEntry | 1.3.6.1.4.1.53973.1.1.13.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups12BypassLineIndex | 1.3.6.1.4.1.53973.1.1.13.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups12BypassVoltage | 1.3.6.1.4.1.53973.1.1.13.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups12BypassCurrent | 1.3.6.1.4.1.53973.1.1.13.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups12BypassPower | 1.3.6.1.4.1.53973.1.1.13.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups12Alarm | 1.3.6.1.4.1.53973.1.1.13.1.6 | ||||||||||||
| Sups12AlarmsPresent | 1.3.6.1.4.1.53973.1.1.13.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups12AlarmTable | 1.3.6.1.4.1.53973.1.1.13.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups12AlarmId equal to 1, and increments the value of ups12AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups12AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups12AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups12AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups12AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups12AlarmsPresent. | |||||||||||||
| Rups12AlarmEntry | 1.3.6.1.4.1.53973.1.1.13.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups12AlarmId | 1.3.6.1.4.1.53973.1.1.13.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups12AlarmDescr | 1.3.6.1.4.1.53973.1.1.13.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups12AlarmTime | 1.3.6.1.4.1.53973.1.1.13.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups12AlarmTime shall equal 0. | |||||||||||||
| Nups12WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.13.1.6.3 | ||||||||||||
| Nups12AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.13.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups12AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.13.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups12AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.13.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups12ConfigLowBattTime. | |||||||||||||
| Nups12AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.13.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups12AlarmTempBad | 1.3.6.1.4.1.53973.1.1.13.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups12AlarmInputBad | 1.3.6.1.4.1.53973.1.1.13.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups12AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.13.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups12AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.13.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups12AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.13.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups12AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.13.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups12AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.13.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups12AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.13.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups12AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.13.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups12AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.13.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups12AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.13.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups12AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.13.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups12AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.13.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups12AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.13.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups12AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.13.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups12AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.13.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups12AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.13.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups12AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.13.1.6.3.22 | ||||||||||||
node · current A ups12ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups12AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.13.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups12AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.13.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups12Test | 1.3.6.1.4.1.53973.1.1.13.1.7 | ||||||||||||
| Sups12TestId | 1.3.6.1.4.1.53973.1.1.13.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups12TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups12TestResultsSummary. Tests in progress may be aborted by setting the ups12TestId variable to ups12TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups12TestNoTestsInitiated is returned. | |||||||||||||
| Sups12TestSpinLock | 1.3.6.1.4.1.53973.1.1.13.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups12TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups12TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups12TestResultsSummary */
get (upsTestSpinLock, ups12TestResultsSummary,
ups12TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups12TestResultsSummary,
ups12TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups12TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups12TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups12TestResultsSummary | 1.3.6.1.4.1.53973.1.1.13.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups12TestId to ups12TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups12TestResultsDetail | 1.3.6.1.4.1.53973.1.1.13.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups12TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups12TestStartTime | 1.3.6.1.4.1.53973.1.1.13.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups12TestResultsSummary is noTestsInitiated(6), ups12TestStartTime has the value 0. | |||||||||||||
| Sups12TestElapsedTime | 1.3.6.1.4.1.53973.1.1.13.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups12TestResultsSummary is noTestsInitiated(6), ups12TestElapsedTime has the value 0. | |||||||||||||
| Nups12WellKnownTests | 1.3.6.1.4.1.53973.1.1.13.1.7.7 | ||||||||||||
| Nups12TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.13.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups12TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.13.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups12TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.13.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups12TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.13.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups12TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.13.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups12Control | 1.3.6.1.4.1.53973.1.1.13.1.8 | ||||||||||||
| Sups12ShutdownType | 1.3.6.1.4.1.53973.1.1.13.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups12ShutdownAfterDelay and ups12RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups12ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.13.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups12ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups12ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups12ShutdownType = output and the output is already off. When read, ups12ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups12ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups12StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.13.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups12StartupAfterDelay countdown or ups12RebootWithDuration countdown in progress. When read, ups12StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups12RebootWithDuration | 1.3.6.1.4.1.53973.1.1.13.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups12ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups12RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups12Traps | 1.3.6.1.4.1.53973.1.1.13.2 | ||||||||||||
| !ups12TrapOnBattery | 1.3.6.1.4.1.53973.1.1.13.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups12TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.13.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups12TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.13.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups12AlarmOnBattery and ups12AlarmTestInProgress.
| |||||||||||||
| !ups12TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.13.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups12AlarmTestInProgress.
| |||||||||||||
| Nups12Conformance | 1.3.6.1.4.1.53973.1.1.13.3 | ||||||||||||
| Nups12Compliances | 1.3.6.1.4.1.53973.1.1.13.3.1 | ||||||||||||
| Mups12SubsetCompliance | 1.3.6.1.4.1.53973.1.1.13.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups12BasicCompliance | 1.3.6.1.4.1.53973.1.1.13.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups12FullCompliance | 1.3.6.1.4.1.53973.1.1.13.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups12Groups | 1.3.6.1.4.1.53973.1.1.13.3.2 | ||||||||||||
| Nups12SubsetGroups | 1.3.6.1.4.1.53973.1.1.13.3.2.1 | ||||||||||||
| Gups12SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.1.1 | ||||||||||||
group · current The ups12SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups12SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups12SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.1.2 | ||||||||||||
group · current The ups12SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups12SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.1.3 | ||||||||||||
group · current The ups12SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups12SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.1.4 | ||||||||||||
group · current The ups12SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups12SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.1.6 | ||||||||||||
group · current The ups12SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups12SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.1.8 | ||||||||||||
group · current The ups12SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups12BasicGroups | 1.3.6.1.4.1.53973.1.1.13.3.2.2 | ||||||||||||
| Gups12BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.1 | ||||||||||||
group · current The ups12BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups12BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.2 | ||||||||||||
group · current The ups12BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups12BasicInputGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.3 | ||||||||||||
group · current The ups12BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups12BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.4 | ||||||||||||
group · current The ups12BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups12BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.5 | ||||||||||||
group · current The ups12BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups12BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.6 | ||||||||||||
group · current The ups12BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups12BasicTestGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.7 | ||||||||||||
group · current The ups12BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups12BasicControlGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.2.8 | ||||||||||||
group · current The ups12BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups12FullGroups | 1.3.6.1.4.1.53973.1.1.13.3.2.3 | ||||||||||||
| Gups12FullIdentGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.1 | ||||||||||||
group · current The ups12FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups12FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.2 | ||||||||||||
group · current The ups12FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups12FullInputGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.3 | ||||||||||||
group · current The ups12FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups12FullOutputGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.4 | ||||||||||||
group · current The ups12FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups12FullBypassGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.5 | ||||||||||||
group · current The ups12FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups12FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.6 | ||||||||||||
group · current The ups12FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups12FullTestGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.7 | ||||||||||||
group · current The ups12FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups12FullControlGroup | 1.3.6.1.4.1.53973.1.1.13.3.2.3.8 | ||||||||||||
group · current The ups12FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule13 | 1.3.6.1.4.1.53973.1.1.14 | ||||||||||||
| Nups13Objects | 1.3.6.1.4.1.53973.1.1.14.1 | ||||||||||||
| Nups13Ident | 1.3.6.1.4.1.53973.1.1.14.1.1 | ||||||||||||
| Sups13IdentManufacturer | 1.3.6.1.4.1.53973.1.1.14.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups13IdentModel | 1.3.6.1.4.1.53973.1.1.14.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups13IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.14.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups13IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups13IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.14.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups13IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups13IdentName | 1.3.6.1.4.1.53973.1.1.14.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups13IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.14.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups13Battery | 1.3.6.1.4.1.53973.1.1.14.1.2 | ||||||||||||
| Sups13BatteryStatus | 1.3.6.1.4.1.53973.1.1.14.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups13ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups13ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups13SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.14.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups13EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.14.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups13EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.14.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups13BatteryVoltage | 1.3.6.1.4.1.53973.1.1.14.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups13BatteryCurrent | 1.3.6.1.4.1.53973.1.1.14.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups13BatteryTemperature | 1.3.6.1.4.1.53973.1.1.14.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups13Input | 1.3.6.1.4.1.53973.1.1.14.1.3 | ||||||||||||
| Sups13InputLineBads | 1.3.6.1.4.1.53973.1.1.14.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups13InputNumLines | 1.3.6.1.4.1.53973.1.1.14.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups13InputTable | 1.3.6.1.4.1.53973.1.1.14.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups13InputNumLines. | |||||||||||||
| Rups13InputEntry | 1.3.6.1.4.1.53973.1.1.14.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups13InputLineIndex | 1.3.6.1.4.1.53973.1.1.14.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups13InputFrequency | 1.3.6.1.4.1.53973.1.1.14.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups13InputVoltage | 1.3.6.1.4.1.53973.1.1.14.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups13InputCurrent | 1.3.6.1.4.1.53973.1.1.14.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups13InputTruePower | 1.3.6.1.4.1.53973.1.1.14.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups13Output | 1.3.6.1.4.1.53973.1.1.14.1.4 | ||||||||||||
| Sups13OutputSource | 1.3.6.1.4.1.53973.1.1.14.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups13OutputFrequency | 1.3.6.1.4.1.53973.1.1.14.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups13OutputNumLines | 1.3.6.1.4.1.53973.1.1.14.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups13OutputTable | 1.3.6.1.4.1.53973.1.1.14.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups13OutputNumLines. | |||||||||||||
| Rups13OutputEntry | 1.3.6.1.4.1.53973.1.1.14.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups13OutputLineIndex | 1.3.6.1.4.1.53973.1.1.14.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups13OutputVoltage | 1.3.6.1.4.1.53973.1.1.14.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups13OutputCurrent | 1.3.6.1.4.1.53973.1.1.14.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups13OutputPower | 1.3.6.1.4.1.53973.1.1.14.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups13OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.14.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups13Bypass | 1.3.6.1.4.1.53973.1.1.14.1.5 | ||||||||||||
| Sups13BypassFrequency | 1.3.6.1.4.1.53973.1.1.14.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups13BypassNumLines | 1.3.6.1.4.1.53973.1.1.14.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups13BypassTable | 1.3.6.1.4.1.53973.1.1.14.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups13BypassNumLines. | |||||||||||||
| Rups13BypassEntry | 1.3.6.1.4.1.53973.1.1.14.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups13BypassLineIndex | 1.3.6.1.4.1.53973.1.1.14.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups13BypassVoltage | 1.3.6.1.4.1.53973.1.1.14.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups13BypassCurrent | 1.3.6.1.4.1.53973.1.1.14.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups13BypassPower | 1.3.6.1.4.1.53973.1.1.14.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups13Alarm | 1.3.6.1.4.1.53973.1.1.14.1.6 | ||||||||||||
| Sups13AlarmsPresent | 1.3.6.1.4.1.53973.1.1.14.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups13AlarmTable | 1.3.6.1.4.1.53973.1.1.14.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups13AlarmId equal to 1, and increments the value of ups13AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups13AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups13AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups13AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups13AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups13AlarmsPresent. | |||||||||||||
| Rups13AlarmEntry | 1.3.6.1.4.1.53973.1.1.14.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups13AlarmId | 1.3.6.1.4.1.53973.1.1.14.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups13AlarmDescr | 1.3.6.1.4.1.53973.1.1.14.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups13AlarmTime | 1.3.6.1.4.1.53973.1.1.14.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups13AlarmTime shall equal 0. | |||||||||||||
| Nups13WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.14.1.6.3 | ||||||||||||
| Nups13AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.14.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups13AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.14.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups13AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.14.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups13ConfigLowBattTime. | |||||||||||||
| Nups13AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.14.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups13AlarmTempBad | 1.3.6.1.4.1.53973.1.1.14.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups13AlarmInputBad | 1.3.6.1.4.1.53973.1.1.14.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups13AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.14.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups13AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.14.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups13AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.14.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups13AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.14.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups13AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.14.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups13AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.14.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups13AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.14.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups13AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.14.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups13AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.14.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups13AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.14.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups13AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.14.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups13AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.14.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups13AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.14.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups13AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.14.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups13AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.14.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups13AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.14.1.6.3.22 | ||||||||||||
node · current A ups13ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups13AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.14.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups13AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.14.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups13Test | 1.3.6.1.4.1.53973.1.1.14.1.7 | ||||||||||||
| Sups13TestId | 1.3.6.1.4.1.53973.1.1.14.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups13TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups13TestResultsSummary. Tests in progress may be aborted by setting the ups13TestId variable to ups13TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups13TestNoTestsInitiated is returned. | |||||||||||||
| Sups13TestSpinLock | 1.3.6.1.4.1.53973.1.1.14.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups13TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups13TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups13TestResultsSummary */
get (upsTestSpinLock, ups13TestResultsSummary,
ups13TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups13TestResultsSummary,
ups13TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups13TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups13TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups13TestResultsSummary | 1.3.6.1.4.1.53973.1.1.14.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups13TestId to ups13TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups13TestResultsDetail | 1.3.6.1.4.1.53973.1.1.14.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups13TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups13TestStartTime | 1.3.6.1.4.1.53973.1.1.14.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups13TestResultsSummary is noTestsInitiated(6), ups13TestStartTime has the value 0. | |||||||||||||
| Sups13TestElapsedTime | 1.3.6.1.4.1.53973.1.1.14.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups13TestResultsSummary is noTestsInitiated(6), ups13TestElapsedTime has the value 0. | |||||||||||||
| Nups13WellKnownTests | 1.3.6.1.4.1.53973.1.1.14.1.7.7 | ||||||||||||
| Nups13TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.14.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups13TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.14.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups13TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.14.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups13TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.14.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups13TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.14.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups13Control | 1.3.6.1.4.1.53973.1.1.14.1.8 | ||||||||||||
| Sups13ShutdownType | 1.3.6.1.4.1.53973.1.1.14.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups13ShutdownAfterDelay and ups13RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups13ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.14.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups13ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups13ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups13ShutdownType = output and the output is already off. When read, ups13ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups13ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups13StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.14.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups13StartupAfterDelay countdown or ups13RebootWithDuration countdown in progress. When read, ups13StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups13RebootWithDuration | 1.3.6.1.4.1.53973.1.1.14.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups13ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups13RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups13Traps | 1.3.6.1.4.1.53973.1.1.14.2 | ||||||||||||
| !ups13TrapOnBattery | 1.3.6.1.4.1.53973.1.1.14.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups13TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.14.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups13TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.14.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups13AlarmOnBattery and ups13AlarmTestInProgress.
| |||||||||||||
| !ups13TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.14.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups13AlarmTestInProgress.
| |||||||||||||
| Nups13Conformance | 1.3.6.1.4.1.53973.1.1.14.3 | ||||||||||||
| Nups13Compliances | 1.3.6.1.4.1.53973.1.1.14.3.1 | ||||||||||||
| Mups13SubsetCompliance | 1.3.6.1.4.1.53973.1.1.14.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups13BasicCompliance | 1.3.6.1.4.1.53973.1.1.14.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups13FullCompliance | 1.3.6.1.4.1.53973.1.1.14.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups13Groups | 1.3.6.1.4.1.53973.1.1.14.3.2 | ||||||||||||
| Nups13SubsetGroups | 1.3.6.1.4.1.53973.1.1.14.3.2.1 | ||||||||||||
| Gups13SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.1.1 | ||||||||||||
group · current The ups13SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups13SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups13SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.1.2 | ||||||||||||
group · current The ups13SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups13SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.1.3 | ||||||||||||
group · current The ups13SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups13SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.1.4 | ||||||||||||
group · current The ups13SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups13SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.1.6 | ||||||||||||
group · current The ups13SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups13SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.1.8 | ||||||||||||
group · current The ups13SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups13BasicGroups | 1.3.6.1.4.1.53973.1.1.14.3.2.2 | ||||||||||||
| Gups13BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.1 | ||||||||||||
group · current The ups13BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups13BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.2 | ||||||||||||
group · current The ups13BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups13BasicInputGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.3 | ||||||||||||
group · current The ups13BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups13BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.4 | ||||||||||||
group · current The ups13BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups13BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.5 | ||||||||||||
group · current The ups13BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups13BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.6 | ||||||||||||
group · current The ups13BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups13BasicTestGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.7 | ||||||||||||
group · current The ups13BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups13BasicControlGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.2.8 | ||||||||||||
group · current The ups13BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups13FullGroups | 1.3.6.1.4.1.53973.1.1.14.3.2.3 | ||||||||||||
| Gups13FullIdentGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.1 | ||||||||||||
group · current The ups13FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups13FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.2 | ||||||||||||
group · current The ups13FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups13FullInputGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.3 | ||||||||||||
group · current The ups13FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups13FullOutputGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.4 | ||||||||||||
group · current The ups13FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups13FullBypassGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.5 | ||||||||||||
group · current The ups13FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups13FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.6 | ||||||||||||
group · current The ups13FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups13FullTestGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.7 | ||||||||||||
group · current The ups13FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups13FullControlGroup | 1.3.6.1.4.1.53973.1.1.14.3.2.3.8 | ||||||||||||
group · current The ups13FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule14 | 1.3.6.1.4.1.53973.1.1.15 | ||||||||||||
| Nups14Objects | 1.3.6.1.4.1.53973.1.1.15.1 | ||||||||||||
| Nups14Ident | 1.3.6.1.4.1.53973.1.1.15.1.1 | ||||||||||||
| Sups14IdentManufacturer | 1.3.6.1.4.1.53973.1.1.15.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups14IdentModel | 1.3.6.1.4.1.53973.1.1.15.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups14IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.15.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups14IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups14IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.15.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups14IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups14IdentName | 1.3.6.1.4.1.53973.1.1.15.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups14IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.15.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups14Battery | 1.3.6.1.4.1.53973.1.1.15.1.2 | ||||||||||||
| Sups14BatteryStatus | 1.3.6.1.4.1.53973.1.1.15.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups14ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups14ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups14SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.15.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups14EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.15.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups14EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.15.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups14BatteryVoltage | 1.3.6.1.4.1.53973.1.1.15.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups14BatteryCurrent | 1.3.6.1.4.1.53973.1.1.15.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups14BatteryTemperature | 1.3.6.1.4.1.53973.1.1.15.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups14Input | 1.3.6.1.4.1.53973.1.1.15.1.3 | ||||||||||||
| Sups14InputLineBads | 1.3.6.1.4.1.53973.1.1.15.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups14InputNumLines | 1.3.6.1.4.1.53973.1.1.15.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups14InputTable | 1.3.6.1.4.1.53973.1.1.15.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups14InputNumLines. | |||||||||||||
| Rups14InputEntry | 1.3.6.1.4.1.53973.1.1.15.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups14InputLineIndex | 1.3.6.1.4.1.53973.1.1.15.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups14InputFrequency | 1.3.6.1.4.1.53973.1.1.15.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups14InputVoltage | 1.3.6.1.4.1.53973.1.1.15.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups14InputCurrent | 1.3.6.1.4.1.53973.1.1.15.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups14InputTruePower | 1.3.6.1.4.1.53973.1.1.15.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups14Output | 1.3.6.1.4.1.53973.1.1.15.1.4 | ||||||||||||
| Sups14OutputSource | 1.3.6.1.4.1.53973.1.1.15.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups14OutputFrequency | 1.3.6.1.4.1.53973.1.1.15.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups14OutputNumLines | 1.3.6.1.4.1.53973.1.1.15.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups14OutputTable | 1.3.6.1.4.1.53973.1.1.15.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups14OutputNumLines. | |||||||||||||
| Rups14OutputEntry | 1.3.6.1.4.1.53973.1.1.15.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups14OutputLineIndex | 1.3.6.1.4.1.53973.1.1.15.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups14OutputVoltage | 1.3.6.1.4.1.53973.1.1.15.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups14OutputCurrent | 1.3.6.1.4.1.53973.1.1.15.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups14OutputPower | 1.3.6.1.4.1.53973.1.1.15.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups14OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.15.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups14Bypass | 1.3.6.1.4.1.53973.1.1.15.1.5 | ||||||||||||
| Sups14BypassFrequency | 1.3.6.1.4.1.53973.1.1.15.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups14BypassNumLines | 1.3.6.1.4.1.53973.1.1.15.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups14BypassTable | 1.3.6.1.4.1.53973.1.1.15.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups14BypassNumLines. | |||||||||||||
| Rups14BypassEntry | 1.3.6.1.4.1.53973.1.1.15.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups14BypassLineIndex | 1.3.6.1.4.1.53973.1.1.15.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups14BypassVoltage | 1.3.6.1.4.1.53973.1.1.15.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups14BypassCurrent | 1.3.6.1.4.1.53973.1.1.15.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups14BypassPower | 1.3.6.1.4.1.53973.1.1.15.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups14Alarm | 1.3.6.1.4.1.53973.1.1.15.1.6 | ||||||||||||
| Sups14AlarmsPresent | 1.3.6.1.4.1.53973.1.1.15.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups14AlarmTable | 1.3.6.1.4.1.53973.1.1.15.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups14AlarmId equal to 1, and increments the value of ups14AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups14AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups14AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups14AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups14AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups14AlarmsPresent. | |||||||||||||
| Rups14AlarmEntry | 1.3.6.1.4.1.53973.1.1.15.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups14AlarmId | 1.3.6.1.4.1.53973.1.1.15.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups14AlarmDescr | 1.3.6.1.4.1.53973.1.1.15.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups14AlarmTime | 1.3.6.1.4.1.53973.1.1.15.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups14AlarmTime shall equal 0. | |||||||||||||
| Nups14WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.15.1.6.3 | ||||||||||||
| Nups14AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.15.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups14AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.15.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups14AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.15.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups14ConfigLowBattTime. | |||||||||||||
| Nups14AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.15.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups14AlarmTempBad | 1.3.6.1.4.1.53973.1.1.15.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups14AlarmInputBad | 1.3.6.1.4.1.53973.1.1.15.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups14AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.15.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups14AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.15.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups14AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.15.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups14AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.15.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups14AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.15.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups14AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.15.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups14AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.15.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups14AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.15.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups14AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.15.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups14AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.15.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups14AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.15.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups14AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.15.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups14AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.15.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups14AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.15.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups14AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.15.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups14AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.15.1.6.3.22 | ||||||||||||
node · current A ups14ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups14AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.15.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups14AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.15.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups14Test | 1.3.6.1.4.1.53973.1.1.15.1.7 | ||||||||||||
| Sups14TestId | 1.3.6.1.4.1.53973.1.1.15.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups14TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups14TestResultsSummary. Tests in progress may be aborted by setting the ups14TestId variable to ups14TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups14TestNoTestsInitiated is returned. | |||||||||||||
| Sups14TestSpinLock | 1.3.6.1.4.1.53973.1.1.15.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups14TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups14TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups14TestResultsSummary */
get (upsTestSpinLock, ups14TestResultsSummary,
ups14TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups14TestResultsSummary,
ups14TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups14TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups14TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups14TestResultsSummary | 1.3.6.1.4.1.53973.1.1.15.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups14TestId to ups14TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups14TestResultsDetail | 1.3.6.1.4.1.53973.1.1.15.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups14TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups14TestStartTime | 1.3.6.1.4.1.53973.1.1.15.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups14TestResultsSummary is noTestsInitiated(6), ups14TestStartTime has the value 0. | |||||||||||||
| Sups14TestElapsedTime | 1.3.6.1.4.1.53973.1.1.15.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups14TestResultsSummary is noTestsInitiated(6), ups14TestElapsedTime has the value 0. | |||||||||||||
| Nups14WellKnownTests | 1.3.6.1.4.1.53973.1.1.15.1.7.7 | ||||||||||||
| Nups14TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.15.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups14TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.15.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups14TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.15.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups14TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.15.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups14TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.15.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups14Control | 1.3.6.1.4.1.53973.1.1.15.1.8 | ||||||||||||
| Sups14ShutdownType | 1.3.6.1.4.1.53973.1.1.15.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups14ShutdownAfterDelay and ups14RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups14ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.15.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups14ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups14ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups14ShutdownType = output and the output is already off. When read, ups14ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups14ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups14StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.15.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups14StartupAfterDelay countdown or ups14RebootWithDuration countdown in progress. When read, ups14StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups14RebootWithDuration | 1.3.6.1.4.1.53973.1.1.15.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups14ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups14RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups14Traps | 1.3.6.1.4.1.53973.1.1.15.2 | ||||||||||||
| !ups14TrapOnBattery | 1.3.6.1.4.1.53973.1.1.15.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups14TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.15.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups14TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.15.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups14AlarmOnBattery and ups14AlarmTestInProgress.
| |||||||||||||
| !ups14TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.15.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups14AlarmTestInProgress.
| |||||||||||||
| Nups14Conformance | 1.3.6.1.4.1.53973.1.1.15.3 | ||||||||||||
| Nups14Compliances | 1.3.6.1.4.1.53973.1.1.15.3.1 | ||||||||||||
| Mups14SubsetCompliance | 1.3.6.1.4.1.53973.1.1.15.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups14BasicCompliance | 1.3.6.1.4.1.53973.1.1.15.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups14FullCompliance | 1.3.6.1.4.1.53973.1.1.15.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups14Groups | 1.3.6.1.4.1.53973.1.1.15.3.2 | ||||||||||||
| Nups14SubsetGroups | 1.3.6.1.4.1.53973.1.1.15.3.2.1 | ||||||||||||
| Gups14SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.1.1 | ||||||||||||
group · current The ups14SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups14SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups14SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.1.2 | ||||||||||||
group · current The ups14SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups14SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.1.3 | ||||||||||||
group · current The ups14SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups14SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.1.4 | ||||||||||||
group · current The ups14SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups14SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.1.6 | ||||||||||||
group · current The ups14SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups14SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.1.8 | ||||||||||||
group · current The ups14SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups14BasicGroups | 1.3.6.1.4.1.53973.1.1.15.3.2.2 | ||||||||||||
| Gups14BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.1 | ||||||||||||
group · current The ups14BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups14BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.2 | ||||||||||||
group · current The ups14BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups14BasicInputGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.3 | ||||||||||||
group · current The ups14BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups14BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.4 | ||||||||||||
group · current The ups14BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups14BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.5 | ||||||||||||
group · current The ups14BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups14BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.6 | ||||||||||||
group · current The ups14BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups14BasicTestGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.7 | ||||||||||||
group · current The ups14BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups14BasicControlGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.2.8 | ||||||||||||
group · current The ups14BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups14FullGroups | 1.3.6.1.4.1.53973.1.1.15.3.2.3 | ||||||||||||
| Gups14FullIdentGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.1 | ||||||||||||
group · current The ups14FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups14FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.2 | ||||||||||||
group · current The ups14FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups14FullInputGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.3 | ||||||||||||
group · current The ups14FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups14FullOutputGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.4 | ||||||||||||
group · current The ups14FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups14FullBypassGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.5 | ||||||||||||
group · current The ups14FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups14FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.6 | ||||||||||||
group · current The ups14FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups14FullTestGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.7 | ||||||||||||
group · current The ups14FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups14FullControlGroup | 1.3.6.1.4.1.53973.1.1.15.3.2.3.8 | ||||||||||||
group · current The ups14FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule15 | 1.3.6.1.4.1.53973.1.1.16 | ||||||||||||
| Nups15Objects | 1.3.6.1.4.1.53973.1.1.16.1 | ||||||||||||
| Nups15Ident | 1.3.6.1.4.1.53973.1.1.16.1.1 | ||||||||||||
| Sups15IdentManufacturer | 1.3.6.1.4.1.53973.1.1.16.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups15IdentModel | 1.3.6.1.4.1.53973.1.1.16.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups15IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.16.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups15IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups15IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.16.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups15IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups15IdentName | 1.3.6.1.4.1.53973.1.1.16.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups15IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.16.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups15Battery | 1.3.6.1.4.1.53973.1.1.16.1.2 | ||||||||||||
| Sups15BatteryStatus | 1.3.6.1.4.1.53973.1.1.16.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups15ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups15ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups15SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.16.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups15EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.16.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups15EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.16.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups15BatteryVoltage | 1.3.6.1.4.1.53973.1.1.16.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups15BatteryCurrent | 1.3.6.1.4.1.53973.1.1.16.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups15BatteryTemperature | 1.3.6.1.4.1.53973.1.1.16.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups15Input | 1.3.6.1.4.1.53973.1.1.16.1.3 | ||||||||||||
| Sups15InputLineBads | 1.3.6.1.4.1.53973.1.1.16.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups15InputNumLines | 1.3.6.1.4.1.53973.1.1.16.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups15InputTable | 1.3.6.1.4.1.53973.1.1.16.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups15InputNumLines. | |||||||||||||
| Rups15InputEntry | 1.3.6.1.4.1.53973.1.1.16.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups15InputLineIndex | 1.3.6.1.4.1.53973.1.1.16.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups15InputFrequency | 1.3.6.1.4.1.53973.1.1.16.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups15InputVoltage | 1.3.6.1.4.1.53973.1.1.16.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups15InputCurrent | 1.3.6.1.4.1.53973.1.1.16.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups15InputTruePower | 1.3.6.1.4.1.53973.1.1.16.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups15Output | 1.3.6.1.4.1.53973.1.1.16.1.4 | ||||||||||||
| Sups15OutputSource | 1.3.6.1.4.1.53973.1.1.16.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups15OutputFrequency | 1.3.6.1.4.1.53973.1.1.16.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups15OutputNumLines | 1.3.6.1.4.1.53973.1.1.16.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups15OutputTable | 1.3.6.1.4.1.53973.1.1.16.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups15OutputNumLines. | |||||||||||||
| Rups15OutputEntry | 1.3.6.1.4.1.53973.1.1.16.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups15OutputLineIndex | 1.3.6.1.4.1.53973.1.1.16.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups15OutputVoltage | 1.3.6.1.4.1.53973.1.1.16.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups15OutputCurrent | 1.3.6.1.4.1.53973.1.1.16.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups15OutputPower | 1.3.6.1.4.1.53973.1.1.16.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups15OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.16.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups15Bypass | 1.3.6.1.4.1.53973.1.1.16.1.5 | ||||||||||||
| Sups15BypassFrequency | 1.3.6.1.4.1.53973.1.1.16.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups15BypassNumLines | 1.3.6.1.4.1.53973.1.1.16.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups15BypassTable | 1.3.6.1.4.1.53973.1.1.16.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups15BypassNumLines. | |||||||||||||
| Rups15BypassEntry | 1.3.6.1.4.1.53973.1.1.16.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups15BypassLineIndex | 1.3.6.1.4.1.53973.1.1.16.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups15BypassVoltage | 1.3.6.1.4.1.53973.1.1.16.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups15BypassCurrent | 1.3.6.1.4.1.53973.1.1.16.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups15BypassPower | 1.3.6.1.4.1.53973.1.1.16.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups15Alarm | 1.3.6.1.4.1.53973.1.1.16.1.6 | ||||||||||||
| Sups15AlarmsPresent | 1.3.6.1.4.1.53973.1.1.16.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups15AlarmTable | 1.3.6.1.4.1.53973.1.1.16.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups15AlarmId equal to 1, and increments the value of ups15AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups15AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups15AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups15AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups15AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups15AlarmsPresent. | |||||||||||||
| Rups15AlarmEntry | 1.3.6.1.4.1.53973.1.1.16.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups15AlarmId | 1.3.6.1.4.1.53973.1.1.16.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups15AlarmDescr | 1.3.6.1.4.1.53973.1.1.16.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups15AlarmTime | 1.3.6.1.4.1.53973.1.1.16.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups15AlarmTime shall equal 0. | |||||||||||||
| Nups15WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.16.1.6.3 | ||||||||||||
| Nups15AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.16.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups15AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.16.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups15AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.16.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups15ConfigLowBattTime. | |||||||||||||
| Nups15AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.16.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups15AlarmTempBad | 1.3.6.1.4.1.53973.1.1.16.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups15AlarmInputBad | 1.3.6.1.4.1.53973.1.1.16.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups15AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.16.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups15AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.16.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups15AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.16.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups15AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.16.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups15AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.16.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups15AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.16.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups15AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.16.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups15AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.16.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups15AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.16.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups15AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.16.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups15AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.16.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups15AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.16.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups15AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.16.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups15AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.16.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups15AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.16.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups15AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.16.1.6.3.22 | ||||||||||||
node · current A ups15ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups15AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.16.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups15AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.16.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups15Test | 1.3.6.1.4.1.53973.1.1.16.1.7 | ||||||||||||
| Sups15TestId | 1.3.6.1.4.1.53973.1.1.16.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups15TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups15TestResultsSummary. Tests in progress may be aborted by setting the ups15TestId variable to ups15TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups15TestNoTestsInitiated is returned. | |||||||||||||
| Sups15TestSpinLock | 1.3.6.1.4.1.53973.1.1.16.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups15TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups15TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups15TestResultsSummary */
get (upsTestSpinLock, ups15TestResultsSummary,
ups15TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups15TestResultsSummary,
ups15TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups15TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups15TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups15TestResultsSummary | 1.3.6.1.4.1.53973.1.1.16.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups15TestId to ups15TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups15TestResultsDetail | 1.3.6.1.4.1.53973.1.1.16.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups15TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups15TestStartTime | 1.3.6.1.4.1.53973.1.1.16.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups15TestResultsSummary is noTestsInitiated(6), ups15TestStartTime has the value 0. | |||||||||||||
| Sups15TestElapsedTime | 1.3.6.1.4.1.53973.1.1.16.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups15TestResultsSummary is noTestsInitiated(6), ups15TestElapsedTime has the value 0. | |||||||||||||
| Nups15WellKnownTests | 1.3.6.1.4.1.53973.1.1.16.1.7.7 | ||||||||||||
| Nups15TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.16.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups15TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.16.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups15TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.16.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups15TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.16.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups15TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.16.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups15Control | 1.3.6.1.4.1.53973.1.1.16.1.8 | ||||||||||||
| Sups15ShutdownType | 1.3.6.1.4.1.53973.1.1.16.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups15ShutdownAfterDelay and ups15RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups15ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.16.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups15ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups15ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups15ShutdownType = output and the output is already off. When read, ups15ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups15ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups15StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.16.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups15StartupAfterDelay countdown or ups15RebootWithDuration countdown in progress. When read, ups15StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups15RebootWithDuration | 1.3.6.1.4.1.53973.1.1.16.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups15ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups15RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups15Traps | 1.3.6.1.4.1.53973.1.1.16.2 | ||||||||||||
| !ups15TrapOnBattery | 1.3.6.1.4.1.53973.1.1.16.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups15TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.16.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups15TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.16.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups15AlarmOnBattery and ups15AlarmTestInProgress.
| |||||||||||||
| !ups15TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.16.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups15AlarmTestInProgress.
| |||||||||||||
| Nups15Conformance | 1.3.6.1.4.1.53973.1.1.16.3 | ||||||||||||
| Nups15Compliances | 1.3.6.1.4.1.53973.1.1.16.3.1 | ||||||||||||
| Mups15SubsetCompliance | 1.3.6.1.4.1.53973.1.1.16.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups15BasicCompliance | 1.3.6.1.4.1.53973.1.1.16.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups15FullCompliance | 1.3.6.1.4.1.53973.1.1.16.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups15Groups | 1.3.6.1.4.1.53973.1.1.16.3.2 | ||||||||||||
| Nups15SubsetGroups | 1.3.6.1.4.1.53973.1.1.16.3.2.1 | ||||||||||||
| Gups15SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.1.1 | ||||||||||||
group · current The ups15SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups15SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups15SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.1.2 | ||||||||||||
group · current The ups15SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups15SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.1.3 | ||||||||||||
group · current The ups15SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups15SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.1.4 | ||||||||||||
group · current The ups15SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups15SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.1.6 | ||||||||||||
group · current The ups15SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups15SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.1.8 | ||||||||||||
group · current The ups15SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups15BasicGroups | 1.3.6.1.4.1.53973.1.1.16.3.2.2 | ||||||||||||
| Gups15BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.1 | ||||||||||||
group · current The ups15BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups15BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.2 | ||||||||||||
group · current The ups15BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups15BasicInputGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.3 | ||||||||||||
group · current The ups15BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups15BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.4 | ||||||||||||
group · current The ups15BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups15BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.5 | ||||||||||||
group · current The ups15BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups15BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.6 | ||||||||||||
group · current The ups15BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups15BasicTestGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.7 | ||||||||||||
group · current The ups15BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups15BasicControlGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.2.8 | ||||||||||||
group · current The ups15BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups15FullGroups | 1.3.6.1.4.1.53973.1.1.16.3.2.3 | ||||||||||||
| Gups15FullIdentGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.1 | ||||||||||||
group · current The ups15FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups15FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.2 | ||||||||||||
group · current The ups15FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups15FullInputGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.3 | ||||||||||||
group · current The ups15FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups15FullOutputGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.4 | ||||||||||||
group · current The ups15FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups15FullBypassGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.5 | ||||||||||||
group · current The ups15FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups15FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.6 | ||||||||||||
group · current The ups15FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups15FullTestGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.7 | ||||||||||||
group · current The ups15FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups15FullControlGroup | 1.3.6.1.4.1.53973.1.1.16.3.2.3.8 | ||||||||||||
group · current The ups15FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule16 | 1.3.6.1.4.1.53973.1.1.17 | ||||||||||||
| Nups16Objects | 1.3.6.1.4.1.53973.1.1.17.1 | ||||||||||||
| Nups16Ident | 1.3.6.1.4.1.53973.1.1.17.1.1 | ||||||||||||
| Sups16IdentManufacturer | 1.3.6.1.4.1.53973.1.1.17.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups16IdentModel | 1.3.6.1.4.1.53973.1.1.17.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups16IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.17.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups16IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups16IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.17.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups16IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups16IdentName | 1.3.6.1.4.1.53973.1.1.17.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups16IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.17.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups16Battery | 1.3.6.1.4.1.53973.1.1.17.1.2 | ||||||||||||
| Sups16BatteryStatus | 1.3.6.1.4.1.53973.1.1.17.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups16ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups16ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups16SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.17.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups16EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.17.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups16EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.17.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups16BatteryVoltage | 1.3.6.1.4.1.53973.1.1.17.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups16BatteryCurrent | 1.3.6.1.4.1.53973.1.1.17.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups16BatteryTemperature | 1.3.6.1.4.1.53973.1.1.17.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups16Input | 1.3.6.1.4.1.53973.1.1.17.1.3 | ||||||||||||
| Sups16InputLineBads | 1.3.6.1.4.1.53973.1.1.17.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups16InputNumLines | 1.3.6.1.4.1.53973.1.1.17.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups16InputTable | 1.3.6.1.4.1.53973.1.1.17.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups16InputNumLines. | |||||||||||||
| Rups16InputEntry | 1.3.6.1.4.1.53973.1.1.17.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups16InputLineIndex | 1.3.6.1.4.1.53973.1.1.17.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups16InputFrequency | 1.3.6.1.4.1.53973.1.1.17.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups16InputVoltage | 1.3.6.1.4.1.53973.1.1.17.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups16InputCurrent | 1.3.6.1.4.1.53973.1.1.17.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups16InputTruePower | 1.3.6.1.4.1.53973.1.1.17.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups16Output | 1.3.6.1.4.1.53973.1.1.17.1.4 | ||||||||||||
| Sups16OutputSource | 1.3.6.1.4.1.53973.1.1.17.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups16OutputFrequency | 1.3.6.1.4.1.53973.1.1.17.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups16OutputNumLines | 1.3.6.1.4.1.53973.1.1.17.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups16OutputTable | 1.3.6.1.4.1.53973.1.1.17.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups16OutputNumLines. | |||||||||||||
| Rups16OutputEntry | 1.3.6.1.4.1.53973.1.1.17.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups16OutputLineIndex | 1.3.6.1.4.1.53973.1.1.17.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups16OutputVoltage | 1.3.6.1.4.1.53973.1.1.17.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups16OutputCurrent | 1.3.6.1.4.1.53973.1.1.17.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups16OutputPower | 1.3.6.1.4.1.53973.1.1.17.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups16OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.17.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups16Bypass | 1.3.6.1.4.1.53973.1.1.17.1.5 | ||||||||||||
| Sups16BypassFrequency | 1.3.6.1.4.1.53973.1.1.17.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups16BypassNumLines | 1.3.6.1.4.1.53973.1.1.17.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups16BypassTable | 1.3.6.1.4.1.53973.1.1.17.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups16BypassNumLines. | |||||||||||||
| Rups16BypassEntry | 1.3.6.1.4.1.53973.1.1.17.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups16BypassLineIndex | 1.3.6.1.4.1.53973.1.1.17.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups16BypassVoltage | 1.3.6.1.4.1.53973.1.1.17.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups16BypassCurrent | 1.3.6.1.4.1.53973.1.1.17.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups16BypassPower | 1.3.6.1.4.1.53973.1.1.17.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups16Alarm | 1.3.6.1.4.1.53973.1.1.17.1.6 | ||||||||||||
| Sups16AlarmsPresent | 1.3.6.1.4.1.53973.1.1.17.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups16AlarmTable | 1.3.6.1.4.1.53973.1.1.17.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups16AlarmId equal to 1, and increments the value of ups16AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups16AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups16AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups16AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups16AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups16AlarmsPresent. | |||||||||||||
| Rups16AlarmEntry | 1.3.6.1.4.1.53973.1.1.17.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups16AlarmId | 1.3.6.1.4.1.53973.1.1.17.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups16AlarmDescr | 1.3.6.1.4.1.53973.1.1.17.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups16AlarmTime | 1.3.6.1.4.1.53973.1.1.17.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups16AlarmTime shall equal 0. | |||||||||||||
| Nups16WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.17.1.6.3 | ||||||||||||
| Nups16AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.17.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups16AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.17.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups16AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.17.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups16ConfigLowBattTime. | |||||||||||||
| Nups16AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.17.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups16AlarmTempBad | 1.3.6.1.4.1.53973.1.1.17.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups16AlarmInputBad | 1.3.6.1.4.1.53973.1.1.17.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups16AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.17.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups16AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.17.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups16AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.17.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups16AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.17.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups16AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.17.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups16AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.17.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups16AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.17.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups16AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.17.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups16AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.17.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups16AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.17.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups16AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.17.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups16AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.17.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups16AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.17.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups16AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.17.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups16AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.17.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups16AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.17.1.6.3.22 | ||||||||||||
node · current A ups16ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups16AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.17.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups16AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.17.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups16Test | 1.3.6.1.4.1.53973.1.1.17.1.7 | ||||||||||||
| Sups16TestId | 1.3.6.1.4.1.53973.1.1.17.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups16TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups16TestResultsSummary. Tests in progress may be aborted by setting the ups16TestId variable to ups16TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups16TestNoTestsInitiated is returned. | |||||||||||||
| Sups16TestSpinLock | 1.3.6.1.4.1.53973.1.1.17.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups16TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups16TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups16TestResultsSummary */
get (upsTestSpinLock, ups16TestResultsSummary,
ups16TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups16TestResultsSummary,
ups16TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups16TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups16TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups16TestResultsSummary | 1.3.6.1.4.1.53973.1.1.17.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups16TestId to ups16TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups16TestResultsDetail | 1.3.6.1.4.1.53973.1.1.17.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups16TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups16TestStartTime | 1.3.6.1.4.1.53973.1.1.17.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups16TestResultsSummary is noTestsInitiated(6), ups16TestStartTime has the value 0. | |||||||||||||
| Sups16TestElapsedTime | 1.3.6.1.4.1.53973.1.1.17.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups16TestResultsSummary is noTestsInitiated(6), ups16TestElapsedTime has the value 0. | |||||||||||||
| Nups16WellKnownTests | 1.3.6.1.4.1.53973.1.1.17.1.7.7 | ||||||||||||
| Nups16TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.17.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups16TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.17.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups16TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.17.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups16TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.17.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups16TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.17.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups16Control | 1.3.6.1.4.1.53973.1.1.17.1.8 | ||||||||||||
| Sups16ShutdownType | 1.3.6.1.4.1.53973.1.1.17.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups16ShutdownAfterDelay and ups16RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups16ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.17.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups16ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups16ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups16ShutdownType = output and the output is already off. When read, ups16ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups16ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups16StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.17.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups16StartupAfterDelay countdown or ups16RebootWithDuration countdown in progress. When read, ups16StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups16RebootWithDuration | 1.3.6.1.4.1.53973.1.1.17.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups16ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups16RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups16Traps | 1.3.6.1.4.1.53973.1.1.17.2 | ||||||||||||
| !ups16TrapOnBattery | 1.3.6.1.4.1.53973.1.1.17.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups16TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.17.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups16TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.17.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups16AlarmOnBattery and ups16AlarmTestInProgress.
| |||||||||||||
| !ups16TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.17.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups16AlarmTestInProgress.
| |||||||||||||
| Nups16Conformance | 1.3.6.1.4.1.53973.1.1.17.3 | ||||||||||||
| Nups16Compliances | 1.3.6.1.4.1.53973.1.1.17.3.1 | ||||||||||||
| Mups16SubsetCompliance | 1.3.6.1.4.1.53973.1.1.17.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups16BasicCompliance | 1.3.6.1.4.1.53973.1.1.17.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups16FullCompliance | 1.3.6.1.4.1.53973.1.1.17.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups16Groups | 1.3.6.1.4.1.53973.1.1.17.3.2 | ||||||||||||
| Nups16SubsetGroups | 1.3.6.1.4.1.53973.1.1.17.3.2.1 | ||||||||||||
| Gups16SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.1.1 | ||||||||||||
group · current The ups16SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups16SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups16SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.1.2 | ||||||||||||
group · current The ups16SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups16SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.1.3 | ||||||||||||
group · current The ups16SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups16SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.1.4 | ||||||||||||
group · current The ups16SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups16SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.1.6 | ||||||||||||
group · current The ups16SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups16SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.1.8 | ||||||||||||
group · current The ups16SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups16BasicGroups | 1.3.6.1.4.1.53973.1.1.17.3.2.2 | ||||||||||||
| Gups16BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.1 | ||||||||||||
group · current The ups16BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups16BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.2 | ||||||||||||
group · current The ups16BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups16BasicInputGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.3 | ||||||||||||
group · current The ups16BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups16BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.4 | ||||||||||||
group · current The ups16BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups16BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.5 | ||||||||||||
group · current The ups16BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups16BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.6 | ||||||||||||
group · current The ups16BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups16BasicTestGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.7 | ||||||||||||
group · current The ups16BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups16BasicControlGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.2.8 | ||||||||||||
group · current The ups16BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups16FullGroups | 1.3.6.1.4.1.53973.1.1.17.3.2.3 | ||||||||||||
| Gups16FullIdentGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.1 | ||||||||||||
group · current The ups16FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups16FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.2 | ||||||||||||
group · current The ups16FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups16FullInputGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.3 | ||||||||||||
group · current The ups16FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups16FullOutputGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.4 | ||||||||||||
group · current The ups16FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups16FullBypassGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.5 | ||||||||||||
group · current The ups16FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups16FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.6 | ||||||||||||
group · current The ups16FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups16FullTestGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.7 | ||||||||||||
group · current The ups16FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups16FullControlGroup | 1.3.6.1.4.1.53973.1.1.17.3.2.3.8 | ||||||||||||
group · current The ups16FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule17 | 1.3.6.1.4.1.53973.1.1.18 | ||||||||||||
| Nups17Objects | 1.3.6.1.4.1.53973.1.1.18.1 | ||||||||||||
| Nups17Ident | 1.3.6.1.4.1.53973.1.1.18.1.1 | ||||||||||||
| Sups17IdentManufacturer | 1.3.6.1.4.1.53973.1.1.18.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups17IdentModel | 1.3.6.1.4.1.53973.1.1.18.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups17IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.18.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups17IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups17IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.18.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups17IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups17IdentName | 1.3.6.1.4.1.53973.1.1.18.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups17IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.18.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups17Battery | 1.3.6.1.4.1.53973.1.1.18.1.2 | ||||||||||||
| Sups17BatteryStatus | 1.3.6.1.4.1.53973.1.1.18.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups17ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups17ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups17SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.18.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups17EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.18.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups17EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.18.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups17BatteryVoltage | 1.3.6.1.4.1.53973.1.1.18.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups17BatteryCurrent | 1.3.6.1.4.1.53973.1.1.18.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups17BatteryTemperature | 1.3.6.1.4.1.53973.1.1.18.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups17Input | 1.3.6.1.4.1.53973.1.1.18.1.3 | ||||||||||||
| Sups17InputLineBads | 1.3.6.1.4.1.53973.1.1.18.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups17InputNumLines | 1.3.6.1.4.1.53973.1.1.18.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups17InputTable | 1.3.6.1.4.1.53973.1.1.18.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups17InputNumLines. | |||||||||||||
| Rups17InputEntry | 1.3.6.1.4.1.53973.1.1.18.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups17InputLineIndex | 1.3.6.1.4.1.53973.1.1.18.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups17InputFrequency | 1.3.6.1.4.1.53973.1.1.18.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups17InputVoltage | 1.3.6.1.4.1.53973.1.1.18.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups17InputCurrent | 1.3.6.1.4.1.53973.1.1.18.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups17InputTruePower | 1.3.6.1.4.1.53973.1.1.18.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups17Output | 1.3.6.1.4.1.53973.1.1.18.1.4 | ||||||||||||
| Sups17OutputSource | 1.3.6.1.4.1.53973.1.1.18.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups17OutputFrequency | 1.3.6.1.4.1.53973.1.1.18.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups17OutputNumLines | 1.3.6.1.4.1.53973.1.1.18.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups17OutputTable | 1.3.6.1.4.1.53973.1.1.18.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups17OutputNumLines. | |||||||||||||
| Rups17OutputEntry | 1.3.6.1.4.1.53973.1.1.18.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups17OutputLineIndex | 1.3.6.1.4.1.53973.1.1.18.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups17OutputVoltage | 1.3.6.1.4.1.53973.1.1.18.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups17OutputCurrent | 1.3.6.1.4.1.53973.1.1.18.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups17OutputPower | 1.3.6.1.4.1.53973.1.1.18.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups17OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.18.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups17Bypass | 1.3.6.1.4.1.53973.1.1.18.1.5 | ||||||||||||
| Sups17BypassFrequency | 1.3.6.1.4.1.53973.1.1.18.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups17BypassNumLines | 1.3.6.1.4.1.53973.1.1.18.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups17BypassTable | 1.3.6.1.4.1.53973.1.1.18.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups17BypassNumLines. | |||||||||||||
| Rups17BypassEntry | 1.3.6.1.4.1.53973.1.1.18.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups17BypassLineIndex | 1.3.6.1.4.1.53973.1.1.18.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups17BypassVoltage | 1.3.6.1.4.1.53973.1.1.18.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups17BypassCurrent | 1.3.6.1.4.1.53973.1.1.18.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups17BypassPower | 1.3.6.1.4.1.53973.1.1.18.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups17Alarm | 1.3.6.1.4.1.53973.1.1.18.1.6 | ||||||||||||
| Sups17AlarmsPresent | 1.3.6.1.4.1.53973.1.1.18.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups17AlarmTable | 1.3.6.1.4.1.53973.1.1.18.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups17AlarmId equal to 1, and increments the value of ups17AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups17AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups17AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups17AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups17AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups17AlarmsPresent. | |||||||||||||
| Rups17AlarmEntry | 1.3.6.1.4.1.53973.1.1.18.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups17AlarmId | 1.3.6.1.4.1.53973.1.1.18.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups17AlarmDescr | 1.3.6.1.4.1.53973.1.1.18.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups17AlarmTime | 1.3.6.1.4.1.53973.1.1.18.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups17AlarmTime shall equal 0. | |||||||||||||
| Nups17WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.18.1.6.3 | ||||||||||||
| Nups17AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.18.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups17AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.18.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups17AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.18.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups17ConfigLowBattTime. | |||||||||||||
| Nups17AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.18.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups17AlarmTempBad | 1.3.6.1.4.1.53973.1.1.18.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups17AlarmInputBad | 1.3.6.1.4.1.53973.1.1.18.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups17AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.18.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups17AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.18.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups17AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.18.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups17AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.18.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups17AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.18.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups17AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.18.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups17AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.18.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups17AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.18.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups17AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.18.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups17AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.18.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups17AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.18.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups17AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.18.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups17AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.18.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups17AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.18.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups17AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.18.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups17AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.18.1.6.3.22 | ||||||||||||
node · current A ups17ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups17AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.18.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups17AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.18.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups17Test | 1.3.6.1.4.1.53973.1.1.18.1.7 | ||||||||||||
| Sups17TestId | 1.3.6.1.4.1.53973.1.1.18.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups17TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups17TestResultsSummary. Tests in progress may be aborted by setting the ups17TestId variable to ups17TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups17TestNoTestsInitiated is returned. | |||||||||||||
| Sups17TestSpinLock | 1.3.6.1.4.1.53973.1.1.18.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups17TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups17TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups17TestResultsSummary */
get (upsTestSpinLock, ups17TestResultsSummary,
ups17TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups17TestResultsSummary,
ups17TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups17TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups17TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups17TestResultsSummary | 1.3.6.1.4.1.53973.1.1.18.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups17TestId to ups17TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups17TestResultsDetail | 1.3.6.1.4.1.53973.1.1.18.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups17TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups17TestStartTime | 1.3.6.1.4.1.53973.1.1.18.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups17TestResultsSummary is noTestsInitiated(6), ups17TestStartTime has the value 0. | |||||||||||||
| Sups17TestElapsedTime | 1.3.6.1.4.1.53973.1.1.18.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups17TestResultsSummary is noTestsInitiated(6), ups17TestElapsedTime has the value 0. | |||||||||||||
| Nups17WellKnownTests | 1.3.6.1.4.1.53973.1.1.18.1.7.7 | ||||||||||||
| Nups17TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.18.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups17TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.18.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups17TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.18.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups17TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.18.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups17TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.18.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups17Control | 1.3.6.1.4.1.53973.1.1.18.1.8 | ||||||||||||
| Sups17ShutdownType | 1.3.6.1.4.1.53973.1.1.18.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups17ShutdownAfterDelay and ups17RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups17ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.18.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups17ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups17ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups17ShutdownType = output and the output is already off. When read, ups17ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups17ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups17StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.18.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups17StartupAfterDelay countdown or ups17RebootWithDuration countdown in progress. When read, ups17StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups17RebootWithDuration | 1.3.6.1.4.1.53973.1.1.18.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups17ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups17RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups17Traps | 1.3.6.1.4.1.53973.1.1.18.2 | ||||||||||||
| !ups17TrapOnBattery | 1.3.6.1.4.1.53973.1.1.18.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups17TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.18.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups17TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.18.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups17AlarmOnBattery and ups17AlarmTestInProgress.
| |||||||||||||
| !ups17TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.18.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups17AlarmTestInProgress.
| |||||||||||||
| Nups17Conformance | 1.3.6.1.4.1.53973.1.1.18.3 | ||||||||||||
| Nups17Compliances | 1.3.6.1.4.1.53973.1.1.18.3.1 | ||||||||||||
| Mups17SubsetCompliance | 1.3.6.1.4.1.53973.1.1.18.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups17BasicCompliance | 1.3.6.1.4.1.53973.1.1.18.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups17FullCompliance | 1.3.6.1.4.1.53973.1.1.18.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups17Groups | 1.3.6.1.4.1.53973.1.1.18.3.2 | ||||||||||||
| Nups17SubsetGroups | 1.3.6.1.4.1.53973.1.1.18.3.2.1 | ||||||||||||
| Gups17SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.1.1 | ||||||||||||
group · current The ups17SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups17SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups17SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.1.2 | ||||||||||||
group · current The ups17SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups17SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.1.3 | ||||||||||||
group · current The ups17SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups17SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.1.4 | ||||||||||||
group · current The ups17SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups17SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.1.6 | ||||||||||||
group · current The ups17SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups17SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.1.8 | ||||||||||||
group · current The ups17SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups17BasicGroups | 1.3.6.1.4.1.53973.1.1.18.3.2.2 | ||||||||||||
| Gups17BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.1 | ||||||||||||
group · current The ups17BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups17BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.2 | ||||||||||||
group · current The ups17BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups17BasicInputGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.3 | ||||||||||||
group · current The ups17BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups17BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.4 | ||||||||||||
group · current The ups17BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups17BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.5 | ||||||||||||
group · current The ups17BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups17BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.6 | ||||||||||||
group · current The ups17BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups17BasicTestGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.7 | ||||||||||||
group · current The ups17BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups17BasicControlGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.2.8 | ||||||||||||
group · current The ups17BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups17FullGroups | 1.3.6.1.4.1.53973.1.1.18.3.2.3 | ||||||||||||
| Gups17FullIdentGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.1 | ||||||||||||
group · current The ups17FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups17FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.2 | ||||||||||||
group · current The ups17FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups17FullInputGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.3 | ||||||||||||
group · current The ups17FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups17FullOutputGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.4 | ||||||||||||
group · current The ups17FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups17FullBypassGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.5 | ||||||||||||
group · current The ups17FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups17FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.6 | ||||||||||||
group · current The ups17FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups17FullTestGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.7 | ||||||||||||
group · current The ups17FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups17FullControlGroup | 1.3.6.1.4.1.53973.1.1.18.3.2.3.8 | ||||||||||||
group · current The ups17FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule18 | 1.3.6.1.4.1.53973.1.1.19 | ||||||||||||
| Nups18Objects | 1.3.6.1.4.1.53973.1.1.19.1 | ||||||||||||
| Nups18Ident | 1.3.6.1.4.1.53973.1.1.19.1.1 | ||||||||||||
| Sups18IdentManufacturer | 1.3.6.1.4.1.53973.1.1.19.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups18IdentModel | 1.3.6.1.4.1.53973.1.1.19.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups18IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.19.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups18IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups18IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.19.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups18IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups18IdentName | 1.3.6.1.4.1.53973.1.1.19.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups18IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.19.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups18Battery | 1.3.6.1.4.1.53973.1.1.19.1.2 | ||||||||||||
| Sups18BatteryStatus | 1.3.6.1.4.1.53973.1.1.19.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups18ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups18ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups18SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.19.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups18EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.19.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups18EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.19.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups18BatteryVoltage | 1.3.6.1.4.1.53973.1.1.19.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups18BatteryCurrent | 1.3.6.1.4.1.53973.1.1.19.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups18BatteryTemperature | 1.3.6.1.4.1.53973.1.1.19.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups18Input | 1.3.6.1.4.1.53973.1.1.19.1.3 | ||||||||||||
| Sups18InputLineBads | 1.3.6.1.4.1.53973.1.1.19.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups18InputNumLines | 1.3.6.1.4.1.53973.1.1.19.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups18InputTable | 1.3.6.1.4.1.53973.1.1.19.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups18InputNumLines. | |||||||||||||
| Rups18InputEntry | 1.3.6.1.4.1.53973.1.1.19.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups18InputLineIndex | 1.3.6.1.4.1.53973.1.1.19.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups18InputFrequency | 1.3.6.1.4.1.53973.1.1.19.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups18InputVoltage | 1.3.6.1.4.1.53973.1.1.19.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups18InputCurrent | 1.3.6.1.4.1.53973.1.1.19.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups18InputTruePower | 1.3.6.1.4.1.53973.1.1.19.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups18Output | 1.3.6.1.4.1.53973.1.1.19.1.4 | ||||||||||||
| Sups18OutputSource | 1.3.6.1.4.1.53973.1.1.19.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups18OutputFrequency | 1.3.6.1.4.1.53973.1.1.19.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups18OutputNumLines | 1.3.6.1.4.1.53973.1.1.19.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups18OutputTable | 1.3.6.1.4.1.53973.1.1.19.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups18OutputNumLines. | |||||||||||||
| Rups18OutputEntry | 1.3.6.1.4.1.53973.1.1.19.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups18OutputLineIndex | 1.3.6.1.4.1.53973.1.1.19.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups18OutputVoltage | 1.3.6.1.4.1.53973.1.1.19.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups18OutputCurrent | 1.3.6.1.4.1.53973.1.1.19.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups18OutputPower | 1.3.6.1.4.1.53973.1.1.19.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups18OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.19.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups18Bypass | 1.3.6.1.4.1.53973.1.1.19.1.5 | ||||||||||||
| Sups18BypassFrequency | 1.3.6.1.4.1.53973.1.1.19.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups18BypassNumLines | 1.3.6.1.4.1.53973.1.1.19.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups18BypassTable | 1.3.6.1.4.1.53973.1.1.19.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups18BypassNumLines. | |||||||||||||
| Rups18BypassEntry | 1.3.6.1.4.1.53973.1.1.19.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups18BypassLineIndex | 1.3.6.1.4.1.53973.1.1.19.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups18BypassVoltage | 1.3.6.1.4.1.53973.1.1.19.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups18BypassCurrent | 1.3.6.1.4.1.53973.1.1.19.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups18BypassPower | 1.3.6.1.4.1.53973.1.1.19.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups18Alarm | 1.3.6.1.4.1.53973.1.1.19.1.6 | ||||||||||||
| Sups18AlarmsPresent | 1.3.6.1.4.1.53973.1.1.19.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups18AlarmTable | 1.3.6.1.4.1.53973.1.1.19.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups18AlarmId equal to 1, and increments the value of ups18AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups18AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups18AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups18AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups18AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups18AlarmsPresent. | |||||||||||||
| Rups18AlarmEntry | 1.3.6.1.4.1.53973.1.1.19.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups18AlarmId | 1.3.6.1.4.1.53973.1.1.19.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups18AlarmDescr | 1.3.6.1.4.1.53973.1.1.19.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups18AlarmTime | 1.3.6.1.4.1.53973.1.1.19.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups18AlarmTime shall equal 0. | |||||||||||||
| Nups18WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.19.1.6.3 | ||||||||||||
| Nups18AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.19.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups18AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.19.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups18AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.19.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups18ConfigLowBattTime. | |||||||||||||
| Nups18AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.19.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups18AlarmTempBad | 1.3.6.1.4.1.53973.1.1.19.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups18AlarmInputBad | 1.3.6.1.4.1.53973.1.1.19.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups18AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.19.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups18AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.19.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups18AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.19.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups18AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.19.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups18AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.19.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups18AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.19.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups18AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.19.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups18AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.19.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups18AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.19.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups18AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.19.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups18AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.19.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups18AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.19.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups18AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.19.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups18AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.19.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups18AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.19.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups18AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.19.1.6.3.22 | ||||||||||||
node · current A ups18ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups18AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.19.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups18AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.19.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups18Test | 1.3.6.1.4.1.53973.1.1.19.1.7 | ||||||||||||
| Sups18TestId | 1.3.6.1.4.1.53973.1.1.19.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups18TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups18TestResultsSummary. Tests in progress may be aborted by setting the ups18TestId variable to ups18TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups18TestNoTestsInitiated is returned. | |||||||||||||
| Sups18TestSpinLock | 1.3.6.1.4.1.53973.1.1.19.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups18TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups18TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups18TestResultsSummary */
get (upsTestSpinLock, ups18TestResultsSummary,
ups18TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups18TestResultsSummary,
ups18TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups18TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups18TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups18TestResultsSummary | 1.3.6.1.4.1.53973.1.1.19.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups18TestId to ups18TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups18TestResultsDetail | 1.3.6.1.4.1.53973.1.1.19.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups18TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups18TestStartTime | 1.3.6.1.4.1.53973.1.1.19.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups18TestResultsSummary is noTestsInitiated(6), ups18TestStartTime has the value 0. | |||||||||||||
| Sups18TestElapsedTime | 1.3.6.1.4.1.53973.1.1.19.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups18TestResultsSummary is noTestsInitiated(6), ups18TestElapsedTime has the value 0. | |||||||||||||
| Nups18WellKnownTests | 1.3.6.1.4.1.53973.1.1.19.1.7.7 | ||||||||||||
| Nups18TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.19.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups18TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.19.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups18TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.19.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups18TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.19.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups18TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.19.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups18Control | 1.3.6.1.4.1.53973.1.1.19.1.8 | ||||||||||||
| Sups18ShutdownType | 1.3.6.1.4.1.53973.1.1.19.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups18ShutdownAfterDelay and ups18RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups18ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.19.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups18ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups18ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups18ShutdownType = output and the output is already off. When read, ups18ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups18ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups18StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.19.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups18StartupAfterDelay countdown or ups18RebootWithDuration countdown in progress. When read, ups18StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups18RebootWithDuration | 1.3.6.1.4.1.53973.1.1.19.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups18ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups18RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups18Traps | 1.3.6.1.4.1.53973.1.1.19.2 | ||||||||||||
| !ups18TrapOnBattery | 1.3.6.1.4.1.53973.1.1.19.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups18TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.19.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups18TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.19.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups18AlarmOnBattery and ups18AlarmTestInProgress.
| |||||||||||||
| !ups18TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.19.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups18AlarmTestInProgress.
| |||||||||||||
| Nups18Conformance | 1.3.6.1.4.1.53973.1.1.19.3 | ||||||||||||
| Nups18Compliances | 1.3.6.1.4.1.53973.1.1.19.3.1 | ||||||||||||
| Mups18SubsetCompliance | 1.3.6.1.4.1.53973.1.1.19.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups18BasicCompliance | 1.3.6.1.4.1.53973.1.1.19.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups18FullCompliance | 1.3.6.1.4.1.53973.1.1.19.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups18Groups | 1.3.6.1.4.1.53973.1.1.19.3.2 | ||||||||||||
| Nups18SubsetGroups | 1.3.6.1.4.1.53973.1.1.19.3.2.1 | ||||||||||||
| Gups18SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.1.1 | ||||||||||||
group · current The ups18SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups18SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups18SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.1.2 | ||||||||||||
group · current The ups18SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups18SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.1.3 | ||||||||||||
group · current The ups18SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups18SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.1.4 | ||||||||||||
group · current The ups18SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups18SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.1.6 | ||||||||||||
group · current The ups18SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups18SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.1.8 | ||||||||||||
group · current The ups18SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups18BasicGroups | 1.3.6.1.4.1.53973.1.1.19.3.2.2 | ||||||||||||
| Gups18BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.1 | ||||||||||||
group · current The ups18BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups18BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.2 | ||||||||||||
group · current The ups18BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups18BasicInputGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.3 | ||||||||||||
group · current The ups18BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups18BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.4 | ||||||||||||
group · current The ups18BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups18BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.5 | ||||||||||||
group · current The ups18BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups18BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.6 | ||||||||||||
group · current The ups18BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups18BasicTestGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.7 | ||||||||||||
group · current The ups18BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups18BasicControlGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.2.8 | ||||||||||||
group · current The ups18BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups18FullGroups | 1.3.6.1.4.1.53973.1.1.19.3.2.3 | ||||||||||||
| Gups18FullIdentGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.1 | ||||||||||||
group · current The ups18FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups18FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.2 | ||||||||||||
group · current The ups18FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups18FullInputGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.3 | ||||||||||||
group · current The ups18FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups18FullOutputGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.4 | ||||||||||||
group · current The ups18FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups18FullBypassGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.5 | ||||||||||||
group · current The ups18FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups18FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.6 | ||||||||||||
group · current The ups18FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups18FullTestGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.7 | ||||||||||||
group · current The ups18FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups18FullControlGroup | 1.3.6.1.4.1.53973.1.1.19.3.2.3.8 | ||||||||||||
group · current The ups18FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule19 | 1.3.6.1.4.1.53973.1.1.20 | ||||||||||||
| Nups19Objects | 1.3.6.1.4.1.53973.1.1.20.1 | ||||||||||||
| Nups19Ident | 1.3.6.1.4.1.53973.1.1.20.1.1 | ||||||||||||
| Sups19IdentManufacturer | 1.3.6.1.4.1.53973.1.1.20.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups19IdentModel | 1.3.6.1.4.1.53973.1.1.20.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups19IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.20.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups19IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups19IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.20.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups19IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups19IdentName | 1.3.6.1.4.1.53973.1.1.20.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups19IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.20.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups19Battery | 1.3.6.1.4.1.53973.1.1.20.1.2 | ||||||||||||
| Sups19BatteryStatus | 1.3.6.1.4.1.53973.1.1.20.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups19ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups19ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups19SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.20.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups19EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.20.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups19EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.20.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups19BatteryVoltage | 1.3.6.1.4.1.53973.1.1.20.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups19BatteryCurrent | 1.3.6.1.4.1.53973.1.1.20.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups19BatteryTemperature | 1.3.6.1.4.1.53973.1.1.20.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups19Input | 1.3.6.1.4.1.53973.1.1.20.1.3 | ||||||||||||
| Sups19InputLineBads | 1.3.6.1.4.1.53973.1.1.20.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups19InputNumLines | 1.3.6.1.4.1.53973.1.1.20.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups19InputTable | 1.3.6.1.4.1.53973.1.1.20.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups19InputNumLines. | |||||||||||||
| Rups19InputEntry | 1.3.6.1.4.1.53973.1.1.20.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups19InputLineIndex | 1.3.6.1.4.1.53973.1.1.20.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups19InputFrequency | 1.3.6.1.4.1.53973.1.1.20.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups19InputVoltage | 1.3.6.1.4.1.53973.1.1.20.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups19InputCurrent | 1.3.6.1.4.1.53973.1.1.20.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups19InputTruePower | 1.3.6.1.4.1.53973.1.1.20.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups19Output | 1.3.6.1.4.1.53973.1.1.20.1.4 | ||||||||||||
| Sups19OutputSource | 1.3.6.1.4.1.53973.1.1.20.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups19OutputFrequency | 1.3.6.1.4.1.53973.1.1.20.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups19OutputNumLines | 1.3.6.1.4.1.53973.1.1.20.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups19OutputTable | 1.3.6.1.4.1.53973.1.1.20.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups19OutputNumLines. | |||||||||||||
| Rups19OutputEntry | 1.3.6.1.4.1.53973.1.1.20.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups19OutputLineIndex | 1.3.6.1.4.1.53973.1.1.20.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups19OutputVoltage | 1.3.6.1.4.1.53973.1.1.20.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups19OutputCurrent | 1.3.6.1.4.1.53973.1.1.20.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups19OutputPower | 1.3.6.1.4.1.53973.1.1.20.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups19OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.20.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups19Bypass | 1.3.6.1.4.1.53973.1.1.20.1.5 | ||||||||||||
| Sups19BypassFrequency | 1.3.6.1.4.1.53973.1.1.20.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups19BypassNumLines | 1.3.6.1.4.1.53973.1.1.20.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups19BypassTable | 1.3.6.1.4.1.53973.1.1.20.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups19BypassNumLines. | |||||||||||||
| Rups19BypassEntry | 1.3.6.1.4.1.53973.1.1.20.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups19BypassLineIndex | 1.3.6.1.4.1.53973.1.1.20.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups19BypassVoltage | 1.3.6.1.4.1.53973.1.1.20.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups19BypassCurrent | 1.3.6.1.4.1.53973.1.1.20.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups19BypassPower | 1.3.6.1.4.1.53973.1.1.20.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups19Alarm | 1.3.6.1.4.1.53973.1.1.20.1.6 | ||||||||||||
| Sups19AlarmsPresent | 1.3.6.1.4.1.53973.1.1.20.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups19AlarmTable | 1.3.6.1.4.1.53973.1.1.20.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups19AlarmId equal to 1, and increments the value of ups19AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups19AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups19AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups19AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups19AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups19AlarmsPresent. | |||||||||||||
| Rups19AlarmEntry | 1.3.6.1.4.1.53973.1.1.20.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups19AlarmId | 1.3.6.1.4.1.53973.1.1.20.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups19AlarmDescr | 1.3.6.1.4.1.53973.1.1.20.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups19AlarmTime | 1.3.6.1.4.1.53973.1.1.20.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups19AlarmTime shall equal 0. | |||||||||||||
| Nups19WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.20.1.6.3 | ||||||||||||
| Nups19AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.20.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups19AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.20.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups19AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.20.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups19ConfigLowBattTime. | |||||||||||||
| Nups19AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.20.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups19AlarmTempBad | 1.3.6.1.4.1.53973.1.1.20.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups19AlarmInputBad | 1.3.6.1.4.1.53973.1.1.20.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups19AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.20.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups19AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.20.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups19AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.20.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups19AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.20.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups19AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.20.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups19AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.20.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups19AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.20.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups19AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.20.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups19AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.20.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups19AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.20.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups19AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.20.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups19AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.20.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups19AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.20.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups19AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.20.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups19AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.20.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups19AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.20.1.6.3.22 | ||||||||||||
node · current A ups19ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups19AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.20.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups19AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.20.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups19Test | 1.3.6.1.4.1.53973.1.1.20.1.7 | ||||||||||||
| Sups19TestId | 1.3.6.1.4.1.53973.1.1.20.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups19TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups19TestResultsSummary. Tests in progress may be aborted by setting the ups19TestId variable to ups19TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups19TestNoTestsInitiated is returned. | |||||||||||||
| Sups19TestSpinLock | 1.3.6.1.4.1.53973.1.1.20.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups19TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups19TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups19TestResultsSummary */
get (upsTestSpinLock, ups19TestResultsSummary,
ups19TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups19TestResultsSummary,
ups19TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups19TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups19TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups19TestResultsSummary | 1.3.6.1.4.1.53973.1.1.20.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups19TestId to ups19TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups19TestResultsDetail | 1.3.6.1.4.1.53973.1.1.20.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups19TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups19TestStartTime | 1.3.6.1.4.1.53973.1.1.20.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups19TestResultsSummary is noTestsInitiated(6), ups19TestStartTime has the value 0. | |||||||||||||
| Sups19TestElapsedTime | 1.3.6.1.4.1.53973.1.1.20.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups19TestResultsSummary is noTestsInitiated(6), ups19TestElapsedTime has the value 0. | |||||||||||||
| Nups19WellKnownTests | 1.3.6.1.4.1.53973.1.1.20.1.7.7 | ||||||||||||
| Nups19TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.20.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups19TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.20.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups19TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.20.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups19TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.20.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups19TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.20.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups19Control | 1.3.6.1.4.1.53973.1.1.20.1.8 | ||||||||||||
| Sups19ShutdownType | 1.3.6.1.4.1.53973.1.1.20.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups19ShutdownAfterDelay and ups19RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups19ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.20.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups19ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups19ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups19ShutdownType = output and the output is already off. When read, ups19ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups19ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups19StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.20.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups19StartupAfterDelay countdown or ups19RebootWithDuration countdown in progress. When read, ups19StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups19RebootWithDuration | 1.3.6.1.4.1.53973.1.1.20.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups19ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups19RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups19Traps | 1.3.6.1.4.1.53973.1.1.20.2 | ||||||||||||
| !ups19TrapOnBattery | 1.3.6.1.4.1.53973.1.1.20.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups19TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.20.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups19TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.20.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups19AlarmOnBattery and ups19AlarmTestInProgress.
| |||||||||||||
| !ups19TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.20.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups19AlarmTestInProgress.
| |||||||||||||
| Nups19Conformance | 1.3.6.1.4.1.53973.1.1.20.3 | ||||||||||||
| Nups19Compliances | 1.3.6.1.4.1.53973.1.1.20.3.1 | ||||||||||||
| Mups19SubsetCompliance | 1.3.6.1.4.1.53973.1.1.20.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups19BasicCompliance | 1.3.6.1.4.1.53973.1.1.20.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups19FullCompliance | 1.3.6.1.4.1.53973.1.1.20.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups19Groups | 1.3.6.1.4.1.53973.1.1.20.3.2 | ||||||||||||
| Nups19SubsetGroups | 1.3.6.1.4.1.53973.1.1.20.3.2.1 | ||||||||||||
| Gups19SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.1.1 | ||||||||||||
group · current The ups19SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups19SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups19SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.1.2 | ||||||||||||
group · current The ups19SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups19SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.1.3 | ||||||||||||
group · current The ups19SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups19SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.1.4 | ||||||||||||
group · current The ups19SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups19SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.1.6 | ||||||||||||
group · current The ups19SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups19SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.1.8 | ||||||||||||
group · current The ups19SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups19BasicGroups | 1.3.6.1.4.1.53973.1.1.20.3.2.2 | ||||||||||||
| Gups19BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.1 | ||||||||||||
group · current The ups19BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups19BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.2 | ||||||||||||
group · current The ups19BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups19BasicInputGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.3 | ||||||||||||
group · current The ups19BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups19BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.4 | ||||||||||||
group · current The ups19BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups19BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.5 | ||||||||||||
group · current The ups19BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups19BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.6 | ||||||||||||
group · current The ups19BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups19BasicTestGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.7 | ||||||||||||
group · current The ups19BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups19BasicControlGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.2.8 | ||||||||||||
group · current The ups19BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups19FullGroups | 1.3.6.1.4.1.53973.1.1.20.3.2.3 | ||||||||||||
| Gups19FullIdentGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.1 | ||||||||||||
group · current The ups19FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups19FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.2 | ||||||||||||
group · current The ups19FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups19FullInputGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.3 | ||||||||||||
group · current The ups19FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups19FullOutputGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.4 | ||||||||||||
group · current The ups19FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups19FullBypassGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.5 | ||||||||||||
group · current The ups19FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups19FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.6 | ||||||||||||
group · current The ups19FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups19FullTestGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.7 | ||||||||||||
group · current The ups19FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups19FullControlGroup | 1.3.6.1.4.1.53973.1.1.20.3.2.3.8 | ||||||||||||
group · current The ups19FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule20 | 1.3.6.1.4.1.53973.1.1.21 | ||||||||||||
| Nups20Objects | 1.3.6.1.4.1.53973.1.1.21.1 | ||||||||||||
| Nups20Ident | 1.3.6.1.4.1.53973.1.1.21.1.1 | ||||||||||||
| Sups20IdentManufacturer | 1.3.6.1.4.1.53973.1.1.21.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups20IdentModel | 1.3.6.1.4.1.53973.1.1.21.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups20IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.21.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups20IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups20IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.21.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups20IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups20IdentName | 1.3.6.1.4.1.53973.1.1.21.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups20IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.21.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups20Battery | 1.3.6.1.4.1.53973.1.1.21.1.2 | ||||||||||||
| Sups20BatteryStatus | 1.3.6.1.4.1.53973.1.1.21.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups20ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups20ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups20SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.21.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups20EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.21.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups20EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.21.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups20BatteryVoltage | 1.3.6.1.4.1.53973.1.1.21.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups20BatteryCurrent | 1.3.6.1.4.1.53973.1.1.21.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups20BatteryTemperature | 1.3.6.1.4.1.53973.1.1.21.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups20Input | 1.3.6.1.4.1.53973.1.1.21.1.3 | ||||||||||||
| Sups20InputLineBads | 1.3.6.1.4.1.53973.1.1.21.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups20InputNumLines | 1.3.6.1.4.1.53973.1.1.21.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups20InputTable | 1.3.6.1.4.1.53973.1.1.21.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups20InputNumLines. | |||||||||||||
| Rups20InputEntry | 1.3.6.1.4.1.53973.1.1.21.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups20InputLineIndex | 1.3.6.1.4.1.53973.1.1.21.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups20InputFrequency | 1.3.6.1.4.1.53973.1.1.21.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups20InputVoltage | 1.3.6.1.4.1.53973.1.1.21.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups20InputCurrent | 1.3.6.1.4.1.53973.1.1.21.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups20InputTruePower | 1.3.6.1.4.1.53973.1.1.21.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups20Output | 1.3.6.1.4.1.53973.1.1.21.1.4 | ||||||||||||
| Sups20OutputSource | 1.3.6.1.4.1.53973.1.1.21.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups20OutputFrequency | 1.3.6.1.4.1.53973.1.1.21.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups20OutputNumLines | 1.3.6.1.4.1.53973.1.1.21.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups20OutputTable | 1.3.6.1.4.1.53973.1.1.21.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups20OutputNumLines. | |||||||||||||
| Rups20OutputEntry | 1.3.6.1.4.1.53973.1.1.21.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups20OutputLineIndex | 1.3.6.1.4.1.53973.1.1.21.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups20OutputVoltage | 1.3.6.1.4.1.53973.1.1.21.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups20OutputCurrent | 1.3.6.1.4.1.53973.1.1.21.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups20OutputPower | 1.3.6.1.4.1.53973.1.1.21.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups20OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.21.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups20Bypass | 1.3.6.1.4.1.53973.1.1.21.1.5 | ||||||||||||
| Sups20BypassFrequency | 1.3.6.1.4.1.53973.1.1.21.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups20BypassNumLines | 1.3.6.1.4.1.53973.1.1.21.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups20BypassTable | 1.3.6.1.4.1.53973.1.1.21.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups20BypassNumLines. | |||||||||||||
| Rups20BypassEntry | 1.3.6.1.4.1.53973.1.1.21.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups20BypassLineIndex | 1.3.6.1.4.1.53973.1.1.21.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups20BypassVoltage | 1.3.6.1.4.1.53973.1.1.21.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups20BypassCurrent | 1.3.6.1.4.1.53973.1.1.21.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups20BypassPower | 1.3.6.1.4.1.53973.1.1.21.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups20Alarm | 1.3.6.1.4.1.53973.1.1.21.1.6 | ||||||||||||
| Sups20AlarmsPresent | 1.3.6.1.4.1.53973.1.1.21.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups20AlarmTable | 1.3.6.1.4.1.53973.1.1.21.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups20AlarmId equal to 1, and increments the value of ups20AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups20AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups20AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups20AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups20AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups20AlarmsPresent. | |||||||||||||
| Rups20AlarmEntry | 1.3.6.1.4.1.53973.1.1.21.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups20AlarmId | 1.3.6.1.4.1.53973.1.1.21.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups20AlarmDescr | 1.3.6.1.4.1.53973.1.1.21.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups20AlarmTime | 1.3.6.1.4.1.53973.1.1.21.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups20AlarmTime shall equal 0. | |||||||||||||
| Nups20WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.21.1.6.3 | ||||||||||||
| Nups20AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.21.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups20AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.21.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups20AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.21.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups20ConfigLowBattTime. | |||||||||||||
| Nups20AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.21.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups20AlarmTempBad | 1.3.6.1.4.1.53973.1.1.21.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups20AlarmInputBad | 1.3.6.1.4.1.53973.1.1.21.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups20AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.21.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups20AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.21.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups20AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.21.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups20AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.21.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups20AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.21.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups20AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.21.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups20AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.21.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups20AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.21.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups20AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.21.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups20AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.21.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups20AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.21.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups20AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.21.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups20AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.21.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups20AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.21.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups20AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.21.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups20AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.21.1.6.3.22 | ||||||||||||
node · current A ups20ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups20AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.21.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups20AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.21.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups20Test | 1.3.6.1.4.1.53973.1.1.21.1.7 | ||||||||||||
| Sups20TestId | 1.3.6.1.4.1.53973.1.1.21.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups20TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups20TestResultsSummary. Tests in progress may be aborted by setting the ups20TestId variable to ups20TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups20TestNoTestsInitiated is returned. | |||||||||||||
| Sups20TestSpinLock | 1.3.6.1.4.1.53973.1.1.21.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups20TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups20TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups20TestResultsSummary */
get (upsTestSpinLock, ups20TestResultsSummary,
ups20TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups20TestResultsSummary,
ups20TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups20TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups20TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups20TestResultsSummary | 1.3.6.1.4.1.53973.1.1.21.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups20TestId to ups20TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups20TestResultsDetail | 1.3.6.1.4.1.53973.1.1.21.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups20TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups20TestStartTime | 1.3.6.1.4.1.53973.1.1.21.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups20TestResultsSummary is noTestsInitiated(6), ups20TestStartTime has the value 0. | |||||||||||||
| Sups20TestElapsedTime | 1.3.6.1.4.1.53973.1.1.21.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups20TestResultsSummary is noTestsInitiated(6), ups20TestElapsedTime has the value 0. | |||||||||||||
| Nups20WellKnownTests | 1.3.6.1.4.1.53973.1.1.21.1.7.7 | ||||||||||||
| Nups20TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.21.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups20TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.21.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups20TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.21.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups20TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.21.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups20TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.21.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups20Control | 1.3.6.1.4.1.53973.1.1.21.1.8 | ||||||||||||
| Sups20ShutdownType | 1.3.6.1.4.1.53973.1.1.21.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups20ShutdownAfterDelay and ups20RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups20ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.21.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups20ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups20ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups20ShutdownType = output and the output is already off. When read, ups20ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups20ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups20StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.21.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups20StartupAfterDelay countdown or ups20RebootWithDuration countdown in progress. When read, ups20StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups20RebootWithDuration | 1.3.6.1.4.1.53973.1.1.21.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups20ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups20RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups20Traps | 1.3.6.1.4.1.53973.1.1.21.2 | ||||||||||||
| !ups20TrapOnBattery | 1.3.6.1.4.1.53973.1.1.21.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups20TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.21.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups20TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.21.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups20AlarmOnBattery and ups20AlarmTestInProgress.
| |||||||||||||
| !ups20TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.21.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups20AlarmTestInProgress.
| |||||||||||||
| Nups20Conformance | 1.3.6.1.4.1.53973.1.1.21.3 | ||||||||||||
| Nups20Compliances | 1.3.6.1.4.1.53973.1.1.21.3.1 | ||||||||||||
| Mups20SubsetCompliance | 1.3.6.1.4.1.53973.1.1.21.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups20BasicCompliance | 1.3.6.1.4.1.53973.1.1.21.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups20FullCompliance | 1.3.6.1.4.1.53973.1.1.21.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups20Groups | 1.3.6.1.4.1.53973.1.1.21.3.2 | ||||||||||||
| Nups20SubsetGroups | 1.3.6.1.4.1.53973.1.1.21.3.2.1 | ||||||||||||
| Gups20SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.1.1 | ||||||||||||
group · current The ups20SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups20SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups20SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.1.2 | ||||||||||||
group · current The ups20SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups20SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.1.3 | ||||||||||||
group · current The ups20SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups20SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.1.4 | ||||||||||||
group · current The ups20SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups20SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.1.6 | ||||||||||||
group · current The ups20SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups20SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.1.8 | ||||||||||||
group · current The ups20SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups20BasicGroups | 1.3.6.1.4.1.53973.1.1.21.3.2.2 | ||||||||||||
| Gups20BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.1 | ||||||||||||
group · current The ups20BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups20BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.2 | ||||||||||||
group · current The ups20BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups20BasicInputGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.3 | ||||||||||||
group · current The ups20BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups20BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.4 | ||||||||||||
group · current The ups20BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups20BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.5 | ||||||||||||
group · current The ups20BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups20BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.6 | ||||||||||||
group · current The ups20BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups20BasicTestGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.7 | ||||||||||||
group · current The ups20BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups20BasicControlGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.2.8 | ||||||||||||
group · current The ups20BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups20FullGroups | 1.3.6.1.4.1.53973.1.1.21.3.2.3 | ||||||||||||
| Gups20FullIdentGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.1 | ||||||||||||
group · current The ups20FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups20FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.2 | ||||||||||||
group · current The ups20FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups20FullInputGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.3 | ||||||||||||
group · current The ups20FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups20FullOutputGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.4 | ||||||||||||
group · current The ups20FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups20FullBypassGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.5 | ||||||||||||
group · current The ups20FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups20FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.6 | ||||||||||||
group · current The ups20FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups20FullTestGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.7 | ||||||||||||
group · current The ups20FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups20FullControlGroup | 1.3.6.1.4.1.53973.1.1.21.3.2.3.8 | ||||||||||||
group · current The ups20FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule21 | 1.3.6.1.4.1.53973.1.1.22 | ||||||||||||
| Nups21Objects | 1.3.6.1.4.1.53973.1.1.22.1 | ||||||||||||
| Nups21Ident | 1.3.6.1.4.1.53973.1.1.22.1.1 | ||||||||||||
| Sups21IdentManufacturer | 1.3.6.1.4.1.53973.1.1.22.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups21IdentModel | 1.3.6.1.4.1.53973.1.1.22.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups21IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.22.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups21IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups21IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.22.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups21IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups21IdentName | 1.3.6.1.4.1.53973.1.1.22.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups21IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.22.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups21Battery | 1.3.6.1.4.1.53973.1.1.22.1.2 | ||||||||||||
| Sups21BatteryStatus | 1.3.6.1.4.1.53973.1.1.22.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups21ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups21ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups21SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.22.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups21EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.22.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups21EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.22.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups21BatteryVoltage | 1.3.6.1.4.1.53973.1.1.22.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups21BatteryCurrent | 1.3.6.1.4.1.53973.1.1.22.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups21BatteryTemperature | 1.3.6.1.4.1.53973.1.1.22.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups21Input | 1.3.6.1.4.1.53973.1.1.22.1.3 | ||||||||||||
| Sups21InputLineBads | 1.3.6.1.4.1.53973.1.1.22.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups21InputNumLines | 1.3.6.1.4.1.53973.1.1.22.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups21InputTable | 1.3.6.1.4.1.53973.1.1.22.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups21InputNumLines. | |||||||||||||
| Rups21InputEntry | 1.3.6.1.4.1.53973.1.1.22.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups21InputLineIndex | 1.3.6.1.4.1.53973.1.1.22.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups21InputFrequency | 1.3.6.1.4.1.53973.1.1.22.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups21InputVoltage | 1.3.6.1.4.1.53973.1.1.22.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups21InputCurrent | 1.3.6.1.4.1.53973.1.1.22.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups21InputTruePower | 1.3.6.1.4.1.53973.1.1.22.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups21Output | 1.3.6.1.4.1.53973.1.1.22.1.4 | ||||||||||||
| Sups21OutputSource | 1.3.6.1.4.1.53973.1.1.22.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups21OutputFrequency | 1.3.6.1.4.1.53973.1.1.22.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups21OutputNumLines | 1.3.6.1.4.1.53973.1.1.22.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups21OutputTable | 1.3.6.1.4.1.53973.1.1.22.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups21OutputNumLines. | |||||||||||||
| Rups21OutputEntry | 1.3.6.1.4.1.53973.1.1.22.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups21OutputLineIndex | 1.3.6.1.4.1.53973.1.1.22.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups21OutputVoltage | 1.3.6.1.4.1.53973.1.1.22.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups21OutputCurrent | 1.3.6.1.4.1.53973.1.1.22.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups21OutputPower | 1.3.6.1.4.1.53973.1.1.22.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups21OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.22.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups21Bypass | 1.3.6.1.4.1.53973.1.1.22.1.5 | ||||||||||||
| Sups21BypassFrequency | 1.3.6.1.4.1.53973.1.1.22.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups21BypassNumLines | 1.3.6.1.4.1.53973.1.1.22.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups21BypassTable | 1.3.6.1.4.1.53973.1.1.22.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups21BypassNumLines. | |||||||||||||
| Rups21BypassEntry | 1.3.6.1.4.1.53973.1.1.22.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups21BypassLineIndex | 1.3.6.1.4.1.53973.1.1.22.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups21BypassVoltage | 1.3.6.1.4.1.53973.1.1.22.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups21BypassCurrent | 1.3.6.1.4.1.53973.1.1.22.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups21BypassPower | 1.3.6.1.4.1.53973.1.1.22.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups21Alarm | 1.3.6.1.4.1.53973.1.1.22.1.6 | ||||||||||||
| Sups21AlarmsPresent | 1.3.6.1.4.1.53973.1.1.22.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups21AlarmTable | 1.3.6.1.4.1.53973.1.1.22.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups21AlarmId equal to 1, and increments the value of ups21AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups21AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups21AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups21AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups21AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups21AlarmsPresent. | |||||||||||||
| Rups21AlarmEntry | 1.3.6.1.4.1.53973.1.1.22.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups21AlarmId | 1.3.6.1.4.1.53973.1.1.22.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups21AlarmDescr | 1.3.6.1.4.1.53973.1.1.22.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups21AlarmTime | 1.3.6.1.4.1.53973.1.1.22.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups21AlarmTime shall equal 0. | |||||||||||||
| Nups21WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.22.1.6.3 | ||||||||||||
| Nups21AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.22.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups21AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.22.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups21AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.22.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups21ConfigLowBattTime. | |||||||||||||
| Nups21AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.22.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups21AlarmTempBad | 1.3.6.1.4.1.53973.1.1.22.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups21AlarmInputBad | 1.3.6.1.4.1.53973.1.1.22.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups21AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.22.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups21AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.22.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups21AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.22.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups21AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.22.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups21AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.22.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups21AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.22.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups21AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.22.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups21AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.22.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups21AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.22.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups21AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.22.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups21AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.22.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups21AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.22.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups21AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.22.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups21AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.22.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups21AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.22.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups21AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.22.1.6.3.22 | ||||||||||||
node · current A ups21ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups21AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.22.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups21AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.22.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups21Test | 1.3.6.1.4.1.53973.1.1.22.1.7 | ||||||||||||
| Sups21TestId | 1.3.6.1.4.1.53973.1.1.22.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups21TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups21TestResultsSummary. Tests in progress may be aborted by setting the ups21TestId variable to ups21TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups21TestNoTestsInitiated is returned. | |||||||||||||
| Sups21TestSpinLock | 1.3.6.1.4.1.53973.1.1.22.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups21TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups21TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups21TestResultsSummary */
get (upsTestSpinLock, ups21TestResultsSummary,
ups21TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups21TestResultsSummary,
ups21TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups21TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups21TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups21TestResultsSummary | 1.3.6.1.4.1.53973.1.1.22.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups21TestId to ups21TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups21TestResultsDetail | 1.3.6.1.4.1.53973.1.1.22.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups21TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups21TestStartTime | 1.3.6.1.4.1.53973.1.1.22.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups21TestResultsSummary is noTestsInitiated(6), ups21TestStartTime has the value 0. | |||||||||||||
| Sups21TestElapsedTime | 1.3.6.1.4.1.53973.1.1.22.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups21TestResultsSummary is noTestsInitiated(6), ups21TestElapsedTime has the value 0. | |||||||||||||
| Nups21WellKnownTests | 1.3.6.1.4.1.53973.1.1.22.1.7.7 | ||||||||||||
| Nups21TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.22.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups21TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.22.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups21TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.22.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups21TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.22.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups21TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.22.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups21Control | 1.3.6.1.4.1.53973.1.1.22.1.8 | ||||||||||||
| Sups21ShutdownType | 1.3.6.1.4.1.53973.1.1.22.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups21ShutdownAfterDelay and ups21RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups21ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.22.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups21ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups21ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups21ShutdownType = output and the output is already off. When read, ups21ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups21ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups21StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.22.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups21StartupAfterDelay countdown or ups21RebootWithDuration countdown in progress. When read, ups21StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups21RebootWithDuration | 1.3.6.1.4.1.53973.1.1.22.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups21ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups21RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups21Traps | 1.3.6.1.4.1.53973.1.1.22.2 | ||||||||||||
| !ups21TrapOnBattery | 1.3.6.1.4.1.53973.1.1.22.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups21TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.22.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups21TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.22.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups21AlarmOnBattery and ups21AlarmTestInProgress.
| |||||||||||||
| !ups21TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.22.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups21AlarmTestInProgress.
| |||||||||||||
| Nups21Conformance | 1.3.6.1.4.1.53973.1.1.22.3 | ||||||||||||
| Nups21Compliances | 1.3.6.1.4.1.53973.1.1.22.3.1 | ||||||||||||
| Mups21SubsetCompliance | 1.3.6.1.4.1.53973.1.1.22.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups21BasicCompliance | 1.3.6.1.4.1.53973.1.1.22.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups21FullCompliance | 1.3.6.1.4.1.53973.1.1.22.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups21Groups | 1.3.6.1.4.1.53973.1.1.22.3.2 | ||||||||||||
| Nups21SubsetGroups | 1.3.6.1.4.1.53973.1.1.22.3.2.1 | ||||||||||||
| Gups21SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.1.1 | ||||||||||||
group · current The ups21SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups21SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups21SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.1.2 | ||||||||||||
group · current The ups21SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups21SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.1.3 | ||||||||||||
group · current The ups21SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups21SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.1.4 | ||||||||||||
group · current The ups21SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups21SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.1.6 | ||||||||||||
group · current The ups21SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups21SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.1.8 | ||||||||||||
group · current The ups21SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups21BasicGroups | 1.3.6.1.4.1.53973.1.1.22.3.2.2 | ||||||||||||
| Gups21BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.1 | ||||||||||||
group · current The ups21BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups21BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.2 | ||||||||||||
group · current The ups21BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups21BasicInputGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.3 | ||||||||||||
group · current The ups21BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups21BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.4 | ||||||||||||
group · current The ups21BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups21BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.5 | ||||||||||||
group · current The ups21BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups21BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.6 | ||||||||||||
group · current The ups21BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups21BasicTestGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.7 | ||||||||||||
group · current The ups21BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups21BasicControlGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.2.8 | ||||||||||||
group · current The ups21BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups21FullGroups | 1.3.6.1.4.1.53973.1.1.22.3.2.3 | ||||||||||||
| Gups21FullIdentGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.1 | ||||||||||||
group · current The ups21FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups21FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.2 | ||||||||||||
group · current The ups21FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups21FullInputGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.3 | ||||||||||||
group · current The ups21FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups21FullOutputGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.4 | ||||||||||||
group · current The ups21FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups21FullBypassGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.5 | ||||||||||||
group · current The ups21FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups21FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.6 | ||||||||||||
group · current The ups21FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups21FullTestGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.7 | ||||||||||||
group · current The ups21FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups21FullControlGroup | 1.3.6.1.4.1.53973.1.1.22.3.2.3.8 | ||||||||||||
group · current The ups21FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule22 | 1.3.6.1.4.1.53973.1.1.23 | ||||||||||||
| Nups22Objects | 1.3.6.1.4.1.53973.1.1.23.1 | ||||||||||||
| Nups22Ident | 1.3.6.1.4.1.53973.1.1.23.1.1 | ||||||||||||
| Sups22IdentManufacturer | 1.3.6.1.4.1.53973.1.1.23.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups22IdentModel | 1.3.6.1.4.1.53973.1.1.23.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups22IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.23.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups22IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups22IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.23.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups22IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups22IdentName | 1.3.6.1.4.1.53973.1.1.23.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups22IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.23.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups22Battery | 1.3.6.1.4.1.53973.1.1.23.1.2 | ||||||||||||
| Sups22BatteryStatus | 1.3.6.1.4.1.53973.1.1.23.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups22ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups22ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups22SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.23.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups22EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.23.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups22EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.23.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups22BatteryVoltage | 1.3.6.1.4.1.53973.1.1.23.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups22BatteryCurrent | 1.3.6.1.4.1.53973.1.1.23.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups22BatteryTemperature | 1.3.6.1.4.1.53973.1.1.23.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups22Input | 1.3.6.1.4.1.53973.1.1.23.1.3 | ||||||||||||
| Sups22InputLineBads | 1.3.6.1.4.1.53973.1.1.23.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups22InputNumLines | 1.3.6.1.4.1.53973.1.1.23.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups22InputTable | 1.3.6.1.4.1.53973.1.1.23.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups22InputNumLines. | |||||||||||||
| Rups22InputEntry | 1.3.6.1.4.1.53973.1.1.23.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups22InputLineIndex | 1.3.6.1.4.1.53973.1.1.23.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups22InputFrequency | 1.3.6.1.4.1.53973.1.1.23.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups22InputVoltage | 1.3.6.1.4.1.53973.1.1.23.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups22InputCurrent | 1.3.6.1.4.1.53973.1.1.23.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups22InputTruePower | 1.3.6.1.4.1.53973.1.1.23.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups22Output | 1.3.6.1.4.1.53973.1.1.23.1.4 | ||||||||||||
| Sups22OutputSource | 1.3.6.1.4.1.53973.1.1.23.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups22OutputFrequency | 1.3.6.1.4.1.53973.1.1.23.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups22OutputNumLines | 1.3.6.1.4.1.53973.1.1.23.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups22OutputTable | 1.3.6.1.4.1.53973.1.1.23.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups22OutputNumLines. | |||||||||||||
| Rups22OutputEntry | 1.3.6.1.4.1.53973.1.1.23.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups22OutputLineIndex | 1.3.6.1.4.1.53973.1.1.23.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups22OutputVoltage | 1.3.6.1.4.1.53973.1.1.23.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups22OutputCurrent | 1.3.6.1.4.1.53973.1.1.23.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups22OutputPower | 1.3.6.1.4.1.53973.1.1.23.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups22OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.23.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups22Bypass | 1.3.6.1.4.1.53973.1.1.23.1.5 | ||||||||||||
| Sups22BypassFrequency | 1.3.6.1.4.1.53973.1.1.23.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups22BypassNumLines | 1.3.6.1.4.1.53973.1.1.23.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups22BypassTable | 1.3.6.1.4.1.53973.1.1.23.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups22BypassNumLines. | |||||||||||||
| Rups22BypassEntry | 1.3.6.1.4.1.53973.1.1.23.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups22BypassLineIndex | 1.3.6.1.4.1.53973.1.1.23.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups22BypassVoltage | 1.3.6.1.4.1.53973.1.1.23.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups22BypassCurrent | 1.3.6.1.4.1.53973.1.1.23.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups22BypassPower | 1.3.6.1.4.1.53973.1.1.23.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups22Alarm | 1.3.6.1.4.1.53973.1.1.23.1.6 | ||||||||||||
| Sups22AlarmsPresent | 1.3.6.1.4.1.53973.1.1.23.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups22AlarmTable | 1.3.6.1.4.1.53973.1.1.23.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups22AlarmId equal to 1, and increments the value of ups22AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups22AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups22AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups22AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups22AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups22AlarmsPresent. | |||||||||||||
| Rups22AlarmEntry | 1.3.6.1.4.1.53973.1.1.23.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups22AlarmId | 1.3.6.1.4.1.53973.1.1.23.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups22AlarmDescr | 1.3.6.1.4.1.53973.1.1.23.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups22AlarmTime | 1.3.6.1.4.1.53973.1.1.23.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups22AlarmTime shall equal 0. | |||||||||||||
| Nups22WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.23.1.6.3 | ||||||||||||
| Nups22AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.23.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups22AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.23.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups22AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.23.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups22ConfigLowBattTime. | |||||||||||||
| Nups22AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.23.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups22AlarmTempBad | 1.3.6.1.4.1.53973.1.1.23.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups22AlarmInputBad | 1.3.6.1.4.1.53973.1.1.23.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups22AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.23.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups22AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.23.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups22AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.23.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups22AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.23.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups22AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.23.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups22AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.23.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups22AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.23.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups22AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.23.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups22AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.23.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups22AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.23.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups22AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.23.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups22AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.23.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups22AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.23.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups22AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.23.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups22AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.23.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups22AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.23.1.6.3.22 | ||||||||||||
node · current A ups22ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups22AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.23.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups22AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.23.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups22Test | 1.3.6.1.4.1.53973.1.1.23.1.7 | ||||||||||||
| Sups22TestId | 1.3.6.1.4.1.53973.1.1.23.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups22TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups22TestResultsSummary. Tests in progress may be aborted by setting the ups22TestId variable to ups22TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups22TestNoTestsInitiated is returned. | |||||||||||||
| Sups22TestSpinLock | 1.3.6.1.4.1.53973.1.1.23.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups22TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups22TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups22TestResultsSummary */
get (upsTestSpinLock, ups22TestResultsSummary,
ups22TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups22TestResultsSummary,
ups22TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups22TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups22TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups22TestResultsSummary | 1.3.6.1.4.1.53973.1.1.23.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups22TestId to ups22TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups22TestResultsDetail | 1.3.6.1.4.1.53973.1.1.23.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups22TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups22TestStartTime | 1.3.6.1.4.1.53973.1.1.23.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups22TestResultsSummary is noTestsInitiated(6), ups22TestStartTime has the value 0. | |||||||||||||
| Sups22TestElapsedTime | 1.3.6.1.4.1.53973.1.1.23.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups22TestResultsSummary is noTestsInitiated(6), ups22TestElapsedTime has the value 0. | |||||||||||||
| Nups22WellKnownTests | 1.3.6.1.4.1.53973.1.1.23.1.7.7 | ||||||||||||
| Nups22TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.23.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups22TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.23.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups22TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.23.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups22TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.23.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups22TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.23.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups22Control | 1.3.6.1.4.1.53973.1.1.23.1.8 | ||||||||||||
| Sups22ShutdownType | 1.3.6.1.4.1.53973.1.1.23.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups22ShutdownAfterDelay and ups22RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups22ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.23.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups22ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups22ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups22ShutdownType = output and the output is already off. When read, ups22ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups22ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups22StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.23.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups22StartupAfterDelay countdown or ups22RebootWithDuration countdown in progress. When read, ups22StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups22RebootWithDuration | 1.3.6.1.4.1.53973.1.1.23.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups22ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups22RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups22Traps | 1.3.6.1.4.1.53973.1.1.23.2 | ||||||||||||
| !ups22TrapOnBattery | 1.3.6.1.4.1.53973.1.1.23.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups22TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.23.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups22TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.23.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups22AlarmOnBattery and ups22AlarmTestInProgress.
| |||||||||||||
| !ups22TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.23.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups22AlarmTestInProgress.
| |||||||||||||
| Nups22Conformance | 1.3.6.1.4.1.53973.1.1.23.3 | ||||||||||||
| Nups22Compliances | 1.3.6.1.4.1.53973.1.1.23.3.1 | ||||||||||||
| Mups22SubsetCompliance | 1.3.6.1.4.1.53973.1.1.23.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups22BasicCompliance | 1.3.6.1.4.1.53973.1.1.23.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups22FullCompliance | 1.3.6.1.4.1.53973.1.1.23.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups22Groups | 1.3.6.1.4.1.53973.1.1.23.3.2 | ||||||||||||
| Nups22SubsetGroups | 1.3.6.1.4.1.53973.1.1.23.3.2.1 | ||||||||||||
| Gups22SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.1.1 | ||||||||||||
group · current The ups22SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups22SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups22SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.1.2 | ||||||||||||
group · current The ups22SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups22SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.1.3 | ||||||||||||
group · current The ups22SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups22SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.1.4 | ||||||||||||
group · current The ups22SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups22SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.1.6 | ||||||||||||
group · current The ups22SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups22SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.1.8 | ||||||||||||
group · current The ups22SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups22BasicGroups | 1.3.6.1.4.1.53973.1.1.23.3.2.2 | ||||||||||||
| Gups22BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.1 | ||||||||||||
group · current The ups22BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups22BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.2 | ||||||||||||
group · current The ups22BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups22BasicInputGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.3 | ||||||||||||
group · current The ups22BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups22BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.4 | ||||||||||||
group · current The ups22BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups22BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.5 | ||||||||||||
group · current The ups22BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups22BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.6 | ||||||||||||
group · current The ups22BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups22BasicTestGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.7 | ||||||||||||
group · current The ups22BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups22BasicControlGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.2.8 | ||||||||||||
group · current The ups22BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups22FullGroups | 1.3.6.1.4.1.53973.1.1.23.3.2.3 | ||||||||||||
| Gups22FullIdentGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.1 | ||||||||||||
group · current The ups22FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups22FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.2 | ||||||||||||
group · current The ups22FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups22FullInputGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.3 | ||||||||||||
group · current The ups22FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups22FullOutputGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.4 | ||||||||||||
group · current The ups22FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups22FullBypassGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.5 | ||||||||||||
group · current The ups22FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups22FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.6 | ||||||||||||
group · current The ups22FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups22FullTestGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.7 | ||||||||||||
group · current The ups22FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups22FullControlGroup | 1.3.6.1.4.1.53973.1.1.23.3.2.3.8 | ||||||||||||
group · current The ups22FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule23 | 1.3.6.1.4.1.53973.1.1.24 | ||||||||||||
| Nups23Objects | 1.3.6.1.4.1.53973.1.1.24.1 | ||||||||||||
| Nups23Ident | 1.3.6.1.4.1.53973.1.1.24.1.1 | ||||||||||||
| Sups23IdentManufacturer | 1.3.6.1.4.1.53973.1.1.24.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups23IdentModel | 1.3.6.1.4.1.53973.1.1.24.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups23IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.24.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups23IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups23IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.24.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups23IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups23IdentName | 1.3.6.1.4.1.53973.1.1.24.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups23IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.24.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups23Battery | 1.3.6.1.4.1.53973.1.1.24.1.2 | ||||||||||||
| Sups23BatteryStatus | 1.3.6.1.4.1.53973.1.1.24.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups23ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups23ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups23SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.24.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups23EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.24.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups23EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.24.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups23BatteryVoltage | 1.3.6.1.4.1.53973.1.1.24.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups23BatteryCurrent | 1.3.6.1.4.1.53973.1.1.24.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups23BatteryTemperature | 1.3.6.1.4.1.53973.1.1.24.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups23Input | 1.3.6.1.4.1.53973.1.1.24.1.3 | ||||||||||||
| Sups23InputLineBads | 1.3.6.1.4.1.53973.1.1.24.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups23InputNumLines | 1.3.6.1.4.1.53973.1.1.24.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups23InputTable | 1.3.6.1.4.1.53973.1.1.24.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups23InputNumLines. | |||||||||||||
| Rups23InputEntry | 1.3.6.1.4.1.53973.1.1.24.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups23InputLineIndex | 1.3.6.1.4.1.53973.1.1.24.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups23InputFrequency | 1.3.6.1.4.1.53973.1.1.24.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups23InputVoltage | 1.3.6.1.4.1.53973.1.1.24.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups23InputCurrent | 1.3.6.1.4.1.53973.1.1.24.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups23InputTruePower | 1.3.6.1.4.1.53973.1.1.24.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups23Output | 1.3.6.1.4.1.53973.1.1.24.1.4 | ||||||||||||
| Sups23OutputSource | 1.3.6.1.4.1.53973.1.1.24.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups23OutputFrequency | 1.3.6.1.4.1.53973.1.1.24.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups23OutputNumLines | 1.3.6.1.4.1.53973.1.1.24.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups23OutputTable | 1.3.6.1.4.1.53973.1.1.24.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups23OutputNumLines. | |||||||||||||
| Rups23OutputEntry | 1.3.6.1.4.1.53973.1.1.24.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups23OutputLineIndex | 1.3.6.1.4.1.53973.1.1.24.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups23OutputVoltage | 1.3.6.1.4.1.53973.1.1.24.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups23OutputCurrent | 1.3.6.1.4.1.53973.1.1.24.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups23OutputPower | 1.3.6.1.4.1.53973.1.1.24.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups23OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.24.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups23Bypass | 1.3.6.1.4.1.53973.1.1.24.1.5 | ||||||||||||
| Sups23BypassFrequency | 1.3.6.1.4.1.53973.1.1.24.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups23BypassNumLines | 1.3.6.1.4.1.53973.1.1.24.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups23BypassTable | 1.3.6.1.4.1.53973.1.1.24.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups23BypassNumLines. | |||||||||||||
| Rups23BypassEntry | 1.3.6.1.4.1.53973.1.1.24.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups23BypassLineIndex | 1.3.6.1.4.1.53973.1.1.24.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups23BypassVoltage | 1.3.6.1.4.1.53973.1.1.24.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups23BypassCurrent | 1.3.6.1.4.1.53973.1.1.24.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups23BypassPower | 1.3.6.1.4.1.53973.1.1.24.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups23Alarm | 1.3.6.1.4.1.53973.1.1.24.1.6 | ||||||||||||
| Sups23AlarmsPresent | 1.3.6.1.4.1.53973.1.1.24.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups23AlarmTable | 1.3.6.1.4.1.53973.1.1.24.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups23AlarmId equal to 1, and increments the value of ups23AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups23AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups23AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups23AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups23AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups23AlarmsPresent. | |||||||||||||
| Rups23AlarmEntry | 1.3.6.1.4.1.53973.1.1.24.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups23AlarmId | 1.3.6.1.4.1.53973.1.1.24.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups23AlarmDescr | 1.3.6.1.4.1.53973.1.1.24.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups23AlarmTime | 1.3.6.1.4.1.53973.1.1.24.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups23AlarmTime shall equal 0. | |||||||||||||
| Nups23WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.24.1.6.3 | ||||||||||||
| Nups23AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.24.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups23AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.24.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups23AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.24.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups23ConfigLowBattTime. | |||||||||||||
| Nups23AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.24.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups23AlarmTempBad | 1.3.6.1.4.1.53973.1.1.24.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups23AlarmInputBad | 1.3.6.1.4.1.53973.1.1.24.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups23AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.24.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups23AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.24.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups23AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.24.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups23AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.24.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups23AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.24.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups23AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.24.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups23AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.24.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups23AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.24.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups23AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.24.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups23AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.24.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups23AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.24.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups23AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.24.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups23AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.24.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups23AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.24.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups23AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.24.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups23AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.24.1.6.3.22 | ||||||||||||
node · current A ups23ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups23AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.24.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups23AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.24.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups23Test | 1.3.6.1.4.1.53973.1.1.24.1.7 | ||||||||||||
| Sups23TestId | 1.3.6.1.4.1.53973.1.1.24.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups23TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups23TestResultsSummary. Tests in progress may be aborted by setting the ups23TestId variable to ups23TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups23TestNoTestsInitiated is returned. | |||||||||||||
| Sups23TestSpinLock | 1.3.6.1.4.1.53973.1.1.24.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups23TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups23TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups23TestResultsSummary */
get (upsTestSpinLock, ups23TestResultsSummary,
ups23TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups23TestResultsSummary,
ups23TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups23TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups23TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups23TestResultsSummary | 1.3.6.1.4.1.53973.1.1.24.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups23TestId to ups23TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups23TestResultsDetail | 1.3.6.1.4.1.53973.1.1.24.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups23TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups23TestStartTime | 1.3.6.1.4.1.53973.1.1.24.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups23TestResultsSummary is noTestsInitiated(6), ups23TestStartTime has the value 0. | |||||||||||||
| Sups23TestElapsedTime | 1.3.6.1.4.1.53973.1.1.24.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups23TestResultsSummary is noTestsInitiated(6), ups23TestElapsedTime has the value 0. | |||||||||||||
| Nups23WellKnownTests | 1.3.6.1.4.1.53973.1.1.24.1.7.7 | ||||||||||||
| Nups23TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.24.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups23TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.24.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups23TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.24.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups23TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.24.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups23TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.24.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups23Control | 1.3.6.1.4.1.53973.1.1.24.1.8 | ||||||||||||
| Sups23ShutdownType | 1.3.6.1.4.1.53973.1.1.24.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups23ShutdownAfterDelay and ups23RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups23ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.24.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups23ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups23ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups23ShutdownType = output and the output is already off. When read, ups23ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups23ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups23StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.24.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups23StartupAfterDelay countdown or ups23RebootWithDuration countdown in progress. When read, ups23StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups23RebootWithDuration | 1.3.6.1.4.1.53973.1.1.24.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups23ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups23RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups23Traps | 1.3.6.1.4.1.53973.1.1.24.2 | ||||||||||||
| !ups23TrapOnBattery | 1.3.6.1.4.1.53973.1.1.24.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups23TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.24.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups23TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.24.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups23AlarmOnBattery and ups23AlarmTestInProgress.
| |||||||||||||
| !ups23TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.24.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups23AlarmTestInProgress.
| |||||||||||||
| Nups23Conformance | 1.3.6.1.4.1.53973.1.1.24.3 | ||||||||||||
| Nups23Compliances | 1.3.6.1.4.1.53973.1.1.24.3.1 | ||||||||||||
| Mups23SubsetCompliance | 1.3.6.1.4.1.53973.1.1.24.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups23BasicCompliance | 1.3.6.1.4.1.53973.1.1.24.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups23FullCompliance | 1.3.6.1.4.1.53973.1.1.24.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups23Groups | 1.3.6.1.4.1.53973.1.1.24.3.2 | ||||||||||||
| Nups23SubsetGroups | 1.3.6.1.4.1.53973.1.1.24.3.2.1 | ||||||||||||
| Gups23SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.1.1 | ||||||||||||
group · current The ups23SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups23SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups23SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.1.2 | ||||||||||||
group · current The ups23SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups23SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.1.3 | ||||||||||||
group · current The ups23SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups23SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.1.4 | ||||||||||||
group · current The ups23SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups23SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.1.6 | ||||||||||||
group · current The ups23SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups23SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.1.8 | ||||||||||||
group · current The ups23SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups23BasicGroups | 1.3.6.1.4.1.53973.1.1.24.3.2.2 | ||||||||||||
| Gups23BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.1 | ||||||||||||
group · current The ups23BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups23BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.2 | ||||||||||||
group · current The ups23BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups23BasicInputGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.3 | ||||||||||||
group · current The ups23BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups23BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.4 | ||||||||||||
group · current The ups23BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups23BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.5 | ||||||||||||
group · current The ups23BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups23BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.6 | ||||||||||||
group · current The ups23BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups23BasicTestGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.7 | ||||||||||||
group · current The ups23BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups23BasicControlGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.2.8 | ||||||||||||
group · current The ups23BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups23FullGroups | 1.3.6.1.4.1.53973.1.1.24.3.2.3 | ||||||||||||
| Gups23FullIdentGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.1 | ||||||||||||
group · current The ups23FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups23FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.2 | ||||||||||||
group · current The ups23FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups23FullInputGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.3 | ||||||||||||
group · current The ups23FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups23FullOutputGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.4 | ||||||||||||
group · current The ups23FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups23FullBypassGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.5 | ||||||||||||
group · current The ups23FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups23FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.6 | ||||||||||||
group · current The ups23FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups23FullTestGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.7 | ||||||||||||
group · current The ups23FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups23FullControlGroup | 1.3.6.1.4.1.53973.1.1.24.3.2.3.8 | ||||||||||||
group · current The ups23FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule24 | 1.3.6.1.4.1.53973.1.1.25 | ||||||||||||
| Nups24Objects | 1.3.6.1.4.1.53973.1.1.25.1 | ||||||||||||
| Nups24Ident | 1.3.6.1.4.1.53973.1.1.25.1.1 | ||||||||||||
| Sups24IdentManufacturer | 1.3.6.1.4.1.53973.1.1.25.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups24IdentModel | 1.3.6.1.4.1.53973.1.1.25.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups24IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.25.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups24IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups24IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.25.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups24IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups24IdentName | 1.3.6.1.4.1.53973.1.1.25.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups24IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.25.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups24Battery | 1.3.6.1.4.1.53973.1.1.25.1.2 | ||||||||||||
| Sups24BatteryStatus | 1.3.6.1.4.1.53973.1.1.25.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups24ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups24ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups24SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.25.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups24EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.25.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups24EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.25.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups24BatteryVoltage | 1.3.6.1.4.1.53973.1.1.25.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups24BatteryCurrent | 1.3.6.1.4.1.53973.1.1.25.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups24BatteryTemperature | 1.3.6.1.4.1.53973.1.1.25.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups24Input | 1.3.6.1.4.1.53973.1.1.25.1.3 | ||||||||||||
| Sups24InputLineBads | 1.3.6.1.4.1.53973.1.1.25.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups24InputNumLines | 1.3.6.1.4.1.53973.1.1.25.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups24InputTable | 1.3.6.1.4.1.53973.1.1.25.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups24InputNumLines. | |||||||||||||
| Rups24InputEntry | 1.3.6.1.4.1.53973.1.1.25.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups24InputLineIndex | 1.3.6.1.4.1.53973.1.1.25.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups24InputFrequency | 1.3.6.1.4.1.53973.1.1.25.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups24InputVoltage | 1.3.6.1.4.1.53973.1.1.25.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups24InputCurrent | 1.3.6.1.4.1.53973.1.1.25.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups24InputTruePower | 1.3.6.1.4.1.53973.1.1.25.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups24Output | 1.3.6.1.4.1.53973.1.1.25.1.4 | ||||||||||||
| Sups24OutputSource | 1.3.6.1.4.1.53973.1.1.25.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups24OutputFrequency | 1.3.6.1.4.1.53973.1.1.25.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups24OutputNumLines | 1.3.6.1.4.1.53973.1.1.25.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups24OutputTable | 1.3.6.1.4.1.53973.1.1.25.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups24OutputNumLines. | |||||||||||||
| Rups24OutputEntry | 1.3.6.1.4.1.53973.1.1.25.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups24OutputLineIndex | 1.3.6.1.4.1.53973.1.1.25.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups24OutputVoltage | 1.3.6.1.4.1.53973.1.1.25.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups24OutputCurrent | 1.3.6.1.4.1.53973.1.1.25.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups24OutputPower | 1.3.6.1.4.1.53973.1.1.25.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups24OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.25.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups24Bypass | 1.3.6.1.4.1.53973.1.1.25.1.5 | ||||||||||||
| Sups24BypassFrequency | 1.3.6.1.4.1.53973.1.1.25.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups24BypassNumLines | 1.3.6.1.4.1.53973.1.1.25.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups24BypassTable | 1.3.6.1.4.1.53973.1.1.25.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups24BypassNumLines. | |||||||||||||
| Rups24BypassEntry | 1.3.6.1.4.1.53973.1.1.25.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups24BypassLineIndex | 1.3.6.1.4.1.53973.1.1.25.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups24BypassVoltage | 1.3.6.1.4.1.53973.1.1.25.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups24BypassCurrent | 1.3.6.1.4.1.53973.1.1.25.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups24BypassPower | 1.3.6.1.4.1.53973.1.1.25.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups24Alarm | 1.3.6.1.4.1.53973.1.1.25.1.6 | ||||||||||||
| Sups24AlarmsPresent | 1.3.6.1.4.1.53973.1.1.25.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups24AlarmTable | 1.3.6.1.4.1.53973.1.1.25.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups24AlarmId equal to 1, and increments the value of ups24AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups24AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups24AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups24AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups24AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups24AlarmsPresent. | |||||||||||||
| Rups24AlarmEntry | 1.3.6.1.4.1.53973.1.1.25.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups24AlarmId | 1.3.6.1.4.1.53973.1.1.25.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups24AlarmDescr | 1.3.6.1.4.1.53973.1.1.25.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups24AlarmTime | 1.3.6.1.4.1.53973.1.1.25.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups24AlarmTime shall equal 0. | |||||||||||||
| Nups24WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.25.1.6.3 | ||||||||||||
| Nups24AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.25.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups24AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.25.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups24AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.25.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups24ConfigLowBattTime. | |||||||||||||
| Nups24AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.25.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups24AlarmTempBad | 1.3.6.1.4.1.53973.1.1.25.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups24AlarmInputBad | 1.3.6.1.4.1.53973.1.1.25.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups24AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.25.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups24AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.25.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups24AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.25.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups24AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.25.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups24AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.25.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups24AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.25.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups24AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.25.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups24AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.25.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups24AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.25.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups24AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.25.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups24AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.25.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups24AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.25.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups24AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.25.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups24AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.25.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups24AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.25.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups24AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.25.1.6.3.22 | ||||||||||||
node · current A ups24ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups24AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.25.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups24AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.25.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups24Test | 1.3.6.1.4.1.53973.1.1.25.1.7 | ||||||||||||
| Sups24TestId | 1.3.6.1.4.1.53973.1.1.25.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups24TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups24TestResultsSummary. Tests in progress may be aborted by setting the ups24TestId variable to ups24TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups24TestNoTestsInitiated is returned. | |||||||||||||
| Sups24TestSpinLock | 1.3.6.1.4.1.53973.1.1.25.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups24TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups24TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups24TestResultsSummary */
get (upsTestSpinLock, ups24TestResultsSummary,
ups24TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups24TestResultsSummary,
ups24TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups24TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups24TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups24TestResultsSummary | 1.3.6.1.4.1.53973.1.1.25.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups24TestId to ups24TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups24TestResultsDetail | 1.3.6.1.4.1.53973.1.1.25.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups24TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups24TestStartTime | 1.3.6.1.4.1.53973.1.1.25.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups24TestResultsSummary is noTestsInitiated(6), ups24TestStartTime has the value 0. | |||||||||||||
| Sups24TestElapsedTime | 1.3.6.1.4.1.53973.1.1.25.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups24TestResultsSummary is noTestsInitiated(6), ups24TestElapsedTime has the value 0. | |||||||||||||
| Nups24WellKnownTests | 1.3.6.1.4.1.53973.1.1.25.1.7.7 | ||||||||||||
| Nups24TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.25.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups24TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.25.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups24TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.25.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups24TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.25.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups24TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.25.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups24Control | 1.3.6.1.4.1.53973.1.1.25.1.8 | ||||||||||||
| Sups24ShutdownType | 1.3.6.1.4.1.53973.1.1.25.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups24ShutdownAfterDelay and ups24RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups24ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.25.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups24ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups24ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups24ShutdownType = output and the output is already off. When read, ups24ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups24ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups24StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.25.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups24StartupAfterDelay countdown or ups24RebootWithDuration countdown in progress. When read, ups24StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups24RebootWithDuration | 1.3.6.1.4.1.53973.1.1.25.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups24ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups24RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups24Traps | 1.3.6.1.4.1.53973.1.1.25.2 | ||||||||||||
| !ups24TrapOnBattery | 1.3.6.1.4.1.53973.1.1.25.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups24TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.25.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups24TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.25.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups24AlarmOnBattery and ups24AlarmTestInProgress.
| |||||||||||||
| !ups24TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.25.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups24AlarmTestInProgress.
| |||||||||||||
| Nups24Conformance | 1.3.6.1.4.1.53973.1.1.25.3 | ||||||||||||
| Nups24Compliances | 1.3.6.1.4.1.53973.1.1.25.3.1 | ||||||||||||
| Mups24SubsetCompliance | 1.3.6.1.4.1.53973.1.1.25.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups24BasicCompliance | 1.3.6.1.4.1.53973.1.1.25.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups24FullCompliance | 1.3.6.1.4.1.53973.1.1.25.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups24Groups | 1.3.6.1.4.1.53973.1.1.25.3.2 | ||||||||||||
| Nups24SubsetGroups | 1.3.6.1.4.1.53973.1.1.25.3.2.1 | ||||||||||||
| Gups24SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.1.1 | ||||||||||||
group · current The ups24SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups24SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups24SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.1.2 | ||||||||||||
group · current The ups24SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups24SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.1.3 | ||||||||||||
group · current The ups24SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups24SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.1.4 | ||||||||||||
group · current The ups24SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups24SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.1.6 | ||||||||||||
group · current The ups24SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups24SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.1.8 | ||||||||||||
group · current The ups24SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups24BasicGroups | 1.3.6.1.4.1.53973.1.1.25.3.2.2 | ||||||||||||
| Gups24BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.1 | ||||||||||||
group · current The ups24BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups24BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.2 | ||||||||||||
group · current The ups24BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups24BasicInputGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.3 | ||||||||||||
group · current The ups24BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups24BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.4 | ||||||||||||
group · current The ups24BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups24BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.5 | ||||||||||||
group · current The ups24BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups24BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.6 | ||||||||||||
group · current The ups24BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups24BasicTestGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.7 | ||||||||||||
group · current The ups24BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups24BasicControlGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.2.8 | ||||||||||||
group · current The ups24BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups24FullGroups | 1.3.6.1.4.1.53973.1.1.25.3.2.3 | ||||||||||||
| Gups24FullIdentGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.1 | ||||||||||||
group · current The ups24FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups24FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.2 | ||||||||||||
group · current The ups24FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups24FullInputGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.3 | ||||||||||||
group · current The ups24FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups24FullOutputGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.4 | ||||||||||||
group · current The ups24FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups24FullBypassGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.5 | ||||||||||||
group · current The ups24FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups24FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.6 | ||||||||||||
group · current The ups24FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups24FullTestGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.7 | ||||||||||||
group · current The ups24FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups24FullControlGroup | 1.3.6.1.4.1.53973.1.1.25.3.2.3.8 | ||||||||||||
group · current The ups24FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule25 | 1.3.6.1.4.1.53973.1.1.26 | ||||||||||||
| Nups25Objects | 1.3.6.1.4.1.53973.1.1.26.1 | ||||||||||||
| Nups25Ident | 1.3.6.1.4.1.53973.1.1.26.1.1 | ||||||||||||
| Sups25IdentManufacturer | 1.3.6.1.4.1.53973.1.1.26.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups25IdentModel | 1.3.6.1.4.1.53973.1.1.26.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups25IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.26.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups25IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups25IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.26.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups25IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups25IdentName | 1.3.6.1.4.1.53973.1.1.26.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups25IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.26.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups25Battery | 1.3.6.1.4.1.53973.1.1.26.1.2 | ||||||||||||
| Sups25BatteryStatus | 1.3.6.1.4.1.53973.1.1.26.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups25ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups25ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups25SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.26.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups25EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.26.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups25EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.26.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups25BatteryVoltage | 1.3.6.1.4.1.53973.1.1.26.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups25BatteryCurrent | 1.3.6.1.4.1.53973.1.1.26.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups25BatteryTemperature | 1.3.6.1.4.1.53973.1.1.26.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups25Input | 1.3.6.1.4.1.53973.1.1.26.1.3 | ||||||||||||
| Sups25InputLineBads | 1.3.6.1.4.1.53973.1.1.26.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups25InputNumLines | 1.3.6.1.4.1.53973.1.1.26.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups25InputTable | 1.3.6.1.4.1.53973.1.1.26.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups25InputNumLines. | |||||||||||||
| Rups25InputEntry | 1.3.6.1.4.1.53973.1.1.26.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups25InputLineIndex | 1.3.6.1.4.1.53973.1.1.26.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups25InputFrequency | 1.3.6.1.4.1.53973.1.1.26.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups25InputVoltage | 1.3.6.1.4.1.53973.1.1.26.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups25InputCurrent | 1.3.6.1.4.1.53973.1.1.26.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups25InputTruePower | 1.3.6.1.4.1.53973.1.1.26.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups25Output | 1.3.6.1.4.1.53973.1.1.26.1.4 | ||||||||||||
| Sups25OutputSource | 1.3.6.1.4.1.53973.1.1.26.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups25OutputFrequency | 1.3.6.1.4.1.53973.1.1.26.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups25OutputNumLines | 1.3.6.1.4.1.53973.1.1.26.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups25OutputTable | 1.3.6.1.4.1.53973.1.1.26.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups25OutputNumLines. | |||||||||||||
| Rups25OutputEntry | 1.3.6.1.4.1.53973.1.1.26.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups25OutputLineIndex | 1.3.6.1.4.1.53973.1.1.26.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups25OutputVoltage | 1.3.6.1.4.1.53973.1.1.26.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups25OutputCurrent | 1.3.6.1.4.1.53973.1.1.26.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups25OutputPower | 1.3.6.1.4.1.53973.1.1.26.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups25OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.26.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups25Bypass | 1.3.6.1.4.1.53973.1.1.26.1.5 | ||||||||||||
| Sups25BypassFrequency | 1.3.6.1.4.1.53973.1.1.26.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups25BypassNumLines | 1.3.6.1.4.1.53973.1.1.26.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups25BypassTable | 1.3.6.1.4.1.53973.1.1.26.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups25BypassNumLines. | |||||||||||||
| Rups25BypassEntry | 1.3.6.1.4.1.53973.1.1.26.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups25BypassLineIndex | 1.3.6.1.4.1.53973.1.1.26.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups25BypassVoltage | 1.3.6.1.4.1.53973.1.1.26.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups25BypassCurrent | 1.3.6.1.4.1.53973.1.1.26.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups25BypassPower | 1.3.6.1.4.1.53973.1.1.26.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups25Alarm | 1.3.6.1.4.1.53973.1.1.26.1.6 | ||||||||||||
| Sups25AlarmsPresent | 1.3.6.1.4.1.53973.1.1.26.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups25AlarmTable | 1.3.6.1.4.1.53973.1.1.26.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups25AlarmId equal to 1, and increments the value of ups25AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups25AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups25AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups25AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups25AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups25AlarmsPresent. | |||||||||||||
| Rups25AlarmEntry | 1.3.6.1.4.1.53973.1.1.26.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups25AlarmId | 1.3.6.1.4.1.53973.1.1.26.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups25AlarmDescr | 1.3.6.1.4.1.53973.1.1.26.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups25AlarmTime | 1.3.6.1.4.1.53973.1.1.26.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups25AlarmTime shall equal 0. | |||||||||||||
| Nups25WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.26.1.6.3 | ||||||||||||
| Nups25AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.26.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups25AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.26.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups25AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.26.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups25ConfigLowBattTime. | |||||||||||||
| Nups25AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.26.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups25AlarmTempBad | 1.3.6.1.4.1.53973.1.1.26.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups25AlarmInputBad | 1.3.6.1.4.1.53973.1.1.26.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups25AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.26.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups25AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.26.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups25AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.26.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups25AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.26.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups25AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.26.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups25AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.26.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups25AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.26.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups25AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.26.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups25AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.26.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups25AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.26.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups25AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.26.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups25AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.26.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups25AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.26.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups25AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.26.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups25AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.26.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups25AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.26.1.6.3.22 | ||||||||||||
node · current A ups25ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups25AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.26.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups25AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.26.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups25Test | 1.3.6.1.4.1.53973.1.1.26.1.7 | ||||||||||||
| Sups25TestId | 1.3.6.1.4.1.53973.1.1.26.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups25TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups25TestResultsSummary. Tests in progress may be aborted by setting the ups25TestId variable to ups25TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups25TestNoTestsInitiated is returned. | |||||||||||||
| Sups25TestSpinLock | 1.3.6.1.4.1.53973.1.1.26.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups25TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups25TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups25TestResultsSummary */
get (upsTestSpinLock, ups25TestResultsSummary,
ups25TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups25TestResultsSummary,
ups25TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups25TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups25TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups25TestResultsSummary | 1.3.6.1.4.1.53973.1.1.26.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups25TestId to ups25TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups25TestResultsDetail | 1.3.6.1.4.1.53973.1.1.26.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups25TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups25TestStartTime | 1.3.6.1.4.1.53973.1.1.26.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups25TestResultsSummary is noTestsInitiated(6), ups25TestStartTime has the value 0. | |||||||||||||
| Sups25TestElapsedTime | 1.3.6.1.4.1.53973.1.1.26.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups25TestResultsSummary is noTestsInitiated(6), ups25TestElapsedTime has the value 0. | |||||||||||||
| Nups25WellKnownTests | 1.3.6.1.4.1.53973.1.1.26.1.7.7 | ||||||||||||
| Nups25TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.26.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups25TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.26.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups25TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.26.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups25TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.26.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups25TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.26.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups25Control | 1.3.6.1.4.1.53973.1.1.26.1.8 | ||||||||||||
| Sups25ShutdownType | 1.3.6.1.4.1.53973.1.1.26.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups25ShutdownAfterDelay and ups25RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups25ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.26.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups25ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups25ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups25ShutdownType = output and the output is already off. When read, ups25ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups25ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups25StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.26.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups25StartupAfterDelay countdown or ups25RebootWithDuration countdown in progress. When read, ups25StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups25RebootWithDuration | 1.3.6.1.4.1.53973.1.1.26.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups25ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups25RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups25Traps | 1.3.6.1.4.1.53973.1.1.26.2 | ||||||||||||
| !ups25TrapOnBattery | 1.3.6.1.4.1.53973.1.1.26.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups25TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.26.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups25TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.26.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups25AlarmOnBattery and ups25AlarmTestInProgress.
| |||||||||||||
| !ups25TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.26.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups25AlarmTestInProgress.
| |||||||||||||
| Nups25Conformance | 1.3.6.1.4.1.53973.1.1.26.3 | ||||||||||||
| Nups25Compliances | 1.3.6.1.4.1.53973.1.1.26.3.1 | ||||||||||||
| Mups25SubsetCompliance | 1.3.6.1.4.1.53973.1.1.26.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups25BasicCompliance | 1.3.6.1.4.1.53973.1.1.26.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups25FullCompliance | 1.3.6.1.4.1.53973.1.1.26.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups25Groups | 1.3.6.1.4.1.53973.1.1.26.3.2 | ||||||||||||
| Nups25SubsetGroups | 1.3.6.1.4.1.53973.1.1.26.3.2.1 | ||||||||||||
| Gups25SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.1.1 | ||||||||||||
group · current The ups25SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups25SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups25SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.1.2 | ||||||||||||
group · current The ups25SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups25SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.1.3 | ||||||||||||
group · current The ups25SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups25SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.1.4 | ||||||||||||
group · current The ups25SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups25SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.1.6 | ||||||||||||
group · current The ups25SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups25SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.1.8 | ||||||||||||
group · current The ups25SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups25BasicGroups | 1.3.6.1.4.1.53973.1.1.26.3.2.2 | ||||||||||||
| Gups25BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.1 | ||||||||||||
group · current The ups25BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups25BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.2 | ||||||||||||
group · current The ups25BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups25BasicInputGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.3 | ||||||||||||
group · current The ups25BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups25BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.4 | ||||||||||||
group · current The ups25BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups25BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.5 | ||||||||||||
group · current The ups25BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups25BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.6 | ||||||||||||
group · current The ups25BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups25BasicTestGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.7 | ||||||||||||
group · current The ups25BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups25BasicControlGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.2.8 | ||||||||||||
group · current The ups25BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups25FullGroups | 1.3.6.1.4.1.53973.1.1.26.3.2.3 | ||||||||||||
| Gups25FullIdentGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.1 | ||||||||||||
group · current The ups25FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups25FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.2 | ||||||||||||
group · current The ups25FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups25FullInputGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.3 | ||||||||||||
group · current The ups25FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups25FullOutputGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.4 | ||||||||||||
group · current The ups25FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups25FullBypassGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.5 | ||||||||||||
group · current The ups25FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups25FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.6 | ||||||||||||
group · current The ups25FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups25FullTestGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.7 | ||||||||||||
group · current The ups25FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups25FullControlGroup | 1.3.6.1.4.1.53973.1.1.26.3.2.3.8 | ||||||||||||
group · current The ups25FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule26 | 1.3.6.1.4.1.53973.1.1.27 | ||||||||||||
| Nups26Objects | 1.3.6.1.4.1.53973.1.1.27.1 | ||||||||||||
| Nups26Ident | 1.3.6.1.4.1.53973.1.1.27.1.1 | ||||||||||||
| Sups26IdentManufacturer | 1.3.6.1.4.1.53973.1.1.27.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups26IdentModel | 1.3.6.1.4.1.53973.1.1.27.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups26IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.27.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups26IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups26IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.27.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups26IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups26IdentName | 1.3.6.1.4.1.53973.1.1.27.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups26IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.27.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups26Battery | 1.3.6.1.4.1.53973.1.1.27.1.2 | ||||||||||||
| Sups26BatteryStatus | 1.3.6.1.4.1.53973.1.1.27.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups26ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups26ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups26SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.27.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups26EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.27.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups26EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.27.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups26BatteryVoltage | 1.3.6.1.4.1.53973.1.1.27.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups26BatteryCurrent | 1.3.6.1.4.1.53973.1.1.27.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups26BatteryTemperature | 1.3.6.1.4.1.53973.1.1.27.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups26Input | 1.3.6.1.4.1.53973.1.1.27.1.3 | ||||||||||||
| Sups26InputLineBads | 1.3.6.1.4.1.53973.1.1.27.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups26InputNumLines | 1.3.6.1.4.1.53973.1.1.27.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups26InputTable | 1.3.6.1.4.1.53973.1.1.27.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups26InputNumLines. | |||||||||||||
| Rups26InputEntry | 1.3.6.1.4.1.53973.1.1.27.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups26InputLineIndex | 1.3.6.1.4.1.53973.1.1.27.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups26InputFrequency | 1.3.6.1.4.1.53973.1.1.27.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups26InputVoltage | 1.3.6.1.4.1.53973.1.1.27.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups26InputCurrent | 1.3.6.1.4.1.53973.1.1.27.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups26InputTruePower | 1.3.6.1.4.1.53973.1.1.27.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups26Output | 1.3.6.1.4.1.53973.1.1.27.1.4 | ||||||||||||
| Sups26OutputSource | 1.3.6.1.4.1.53973.1.1.27.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups26OutputFrequency | 1.3.6.1.4.1.53973.1.1.27.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups26OutputNumLines | 1.3.6.1.4.1.53973.1.1.27.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups26OutputTable | 1.3.6.1.4.1.53973.1.1.27.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups26OutputNumLines. | |||||||||||||
| Rups26OutputEntry | 1.3.6.1.4.1.53973.1.1.27.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups26OutputLineIndex | 1.3.6.1.4.1.53973.1.1.27.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups26OutputVoltage | 1.3.6.1.4.1.53973.1.1.27.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups26OutputCurrent | 1.3.6.1.4.1.53973.1.1.27.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups26OutputPower | 1.3.6.1.4.1.53973.1.1.27.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups26OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.27.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups26Bypass | 1.3.6.1.4.1.53973.1.1.27.1.5 | ||||||||||||
| Sups26BypassFrequency | 1.3.6.1.4.1.53973.1.1.27.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups26BypassNumLines | 1.3.6.1.4.1.53973.1.1.27.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups26BypassTable | 1.3.6.1.4.1.53973.1.1.27.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups26BypassNumLines. | |||||||||||||
| Rups26BypassEntry | 1.3.6.1.4.1.53973.1.1.27.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups26BypassLineIndex | 1.3.6.1.4.1.53973.1.1.27.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups26BypassVoltage | 1.3.6.1.4.1.53973.1.1.27.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups26BypassCurrent | 1.3.6.1.4.1.53973.1.1.27.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups26BypassPower | 1.3.6.1.4.1.53973.1.1.27.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups26Alarm | 1.3.6.1.4.1.53973.1.1.27.1.6 | ||||||||||||
| Sups26AlarmsPresent | 1.3.6.1.4.1.53973.1.1.27.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups26AlarmTable | 1.3.6.1.4.1.53973.1.1.27.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups26AlarmId equal to 1, and increments the value of ups26AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups26AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups26AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups26AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups26AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups26AlarmsPresent. | |||||||||||||
| Rups26AlarmEntry | 1.3.6.1.4.1.53973.1.1.27.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups26AlarmId | 1.3.6.1.4.1.53973.1.1.27.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups26AlarmDescr | 1.3.6.1.4.1.53973.1.1.27.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups26AlarmTime | 1.3.6.1.4.1.53973.1.1.27.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups26AlarmTime shall equal 0. | |||||||||||||
| Nups26WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.27.1.6.3 | ||||||||||||
| Nups26AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.27.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups26AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.27.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups26AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.27.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups26ConfigLowBattTime. | |||||||||||||
| Nups26AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.27.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups26AlarmTempBad | 1.3.6.1.4.1.53973.1.1.27.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups26AlarmInputBad | 1.3.6.1.4.1.53973.1.1.27.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups26AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.27.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups26AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.27.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups26AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.27.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups26AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.27.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups26AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.27.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups26AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.27.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups26AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.27.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups26AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.27.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups26AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.27.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups26AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.27.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups26AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.27.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups26AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.27.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups26AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.27.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups26AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.27.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups26AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.27.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups26AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.27.1.6.3.22 | ||||||||||||
node · current A ups26ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups26AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.27.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups26AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.27.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups26Test | 1.3.6.1.4.1.53973.1.1.27.1.7 | ||||||||||||
| Sups26TestId | 1.3.6.1.4.1.53973.1.1.27.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups26TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups26TestResultsSummary. Tests in progress may be aborted by setting the ups26TestId variable to ups26TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups26TestNoTestsInitiated is returned. | |||||||||||||
| Sups26TestSpinLock | 1.3.6.1.4.1.53973.1.1.27.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups26TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups26TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups26TestResultsSummary */
get (upsTestSpinLock, ups26TestResultsSummary,
ups26TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups26TestResultsSummary,
ups26TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups26TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups26TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups26TestResultsSummary | 1.3.6.1.4.1.53973.1.1.27.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups26TestId to ups26TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups26TestResultsDetail | 1.3.6.1.4.1.53973.1.1.27.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups26TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups26TestStartTime | 1.3.6.1.4.1.53973.1.1.27.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups26TestResultsSummary is noTestsInitiated(6), ups26TestStartTime has the value 0. | |||||||||||||
| Sups26TestElapsedTime | 1.3.6.1.4.1.53973.1.1.27.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups26TestResultsSummary is noTestsInitiated(6), ups26TestElapsedTime has the value 0. | |||||||||||||
| Nups26WellKnownTests | 1.3.6.1.4.1.53973.1.1.27.1.7.7 | ||||||||||||
| Nups26TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.27.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups26TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.27.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups26TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.27.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups26TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.27.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups26TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.27.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups26Control | 1.3.6.1.4.1.53973.1.1.27.1.8 | ||||||||||||
| Sups26ShutdownType | 1.3.6.1.4.1.53973.1.1.27.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups26ShutdownAfterDelay and ups26RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups26ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.27.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups26ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups26ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups26ShutdownType = output and the output is already off. When read, ups26ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups26ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups26StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.27.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups26StartupAfterDelay countdown or ups26RebootWithDuration countdown in progress. When read, ups26StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups26RebootWithDuration | 1.3.6.1.4.1.53973.1.1.27.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups26ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups26RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups26Traps | 1.3.6.1.4.1.53973.1.1.27.2 | ||||||||||||
| !ups26TrapOnBattery | 1.3.6.1.4.1.53973.1.1.27.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups26TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.27.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups26TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.27.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups26AlarmOnBattery and ups26AlarmTestInProgress.
| |||||||||||||
| !ups26TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.27.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups26AlarmTestInProgress.
| |||||||||||||
| Nups26Conformance | 1.3.6.1.4.1.53973.1.1.27.3 | ||||||||||||
| Nups26Compliances | 1.3.6.1.4.1.53973.1.1.27.3.1 | ||||||||||||
| Mups26SubsetCompliance | 1.3.6.1.4.1.53973.1.1.27.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups26BasicCompliance | 1.3.6.1.4.1.53973.1.1.27.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups26FullCompliance | 1.3.6.1.4.1.53973.1.1.27.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups26Groups | 1.3.6.1.4.1.53973.1.1.27.3.2 | ||||||||||||
| Nups26SubsetGroups | 1.3.6.1.4.1.53973.1.1.27.3.2.1 | ||||||||||||
| Gups26SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.1.1 | ||||||||||||
group · current The ups26SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups26SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups26SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.1.2 | ||||||||||||
group · current The ups26SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups26SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.1.3 | ||||||||||||
group · current The ups26SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups26SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.1.4 | ||||||||||||
group · current The ups26SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups26SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.1.6 | ||||||||||||
group · current The ups26SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups26SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.1.8 | ||||||||||||
group · current The ups26SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups26BasicGroups | 1.3.6.1.4.1.53973.1.1.27.3.2.2 | ||||||||||||
| Gups26BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.1 | ||||||||||||
group · current The ups26BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups26BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.2 | ||||||||||||
group · current The ups26BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups26BasicInputGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.3 | ||||||||||||
group · current The ups26BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups26BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.4 | ||||||||||||
group · current The ups26BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups26BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.5 | ||||||||||||
group · current The ups26BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups26BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.6 | ||||||||||||
group · current The ups26BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups26BasicTestGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.7 | ||||||||||||
group · current The ups26BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups26BasicControlGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.2.8 | ||||||||||||
group · current The ups26BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups26FullGroups | 1.3.6.1.4.1.53973.1.1.27.3.2.3 | ||||||||||||
| Gups26FullIdentGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.1 | ||||||||||||
group · current The ups26FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups26FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.2 | ||||||||||||
group · current The ups26FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups26FullInputGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.3 | ||||||||||||
group · current The ups26FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups26FullOutputGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.4 | ||||||||||||
group · current The ups26FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups26FullBypassGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.5 | ||||||||||||
group · current The ups26FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups26FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.6 | ||||||||||||
group · current The ups26FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups26FullTestGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.7 | ||||||||||||
group · current The ups26FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups26FullControlGroup | 1.3.6.1.4.1.53973.1.1.27.3.2.3.8 | ||||||||||||
group · current The ups26FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule27 | 1.3.6.1.4.1.53973.1.1.28 | ||||||||||||
| Nups27Objects | 1.3.6.1.4.1.53973.1.1.28.1 | ||||||||||||
| Nups27Ident | 1.3.6.1.4.1.53973.1.1.28.1.1 | ||||||||||||
| Sups27IdentManufacturer | 1.3.6.1.4.1.53973.1.1.28.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups27IdentModel | 1.3.6.1.4.1.53973.1.1.28.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups27IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.28.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups27IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups27IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.28.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups27IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups27IdentName | 1.3.6.1.4.1.53973.1.1.28.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups27IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.28.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups27Battery | 1.3.6.1.4.1.53973.1.1.28.1.2 | ||||||||||||
| Sups27BatteryStatus | 1.3.6.1.4.1.53973.1.1.28.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups27ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups27ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups27SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.28.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups27EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.28.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups27EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.28.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups27BatteryVoltage | 1.3.6.1.4.1.53973.1.1.28.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups27BatteryCurrent | 1.3.6.1.4.1.53973.1.1.28.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups27BatteryTemperature | 1.3.6.1.4.1.53973.1.1.28.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups27Input | 1.3.6.1.4.1.53973.1.1.28.1.3 | ||||||||||||
| Sups27InputLineBads | 1.3.6.1.4.1.53973.1.1.28.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups27InputNumLines | 1.3.6.1.4.1.53973.1.1.28.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups27InputTable | 1.3.6.1.4.1.53973.1.1.28.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups27InputNumLines. | |||||||||||||
| Rups27InputEntry | 1.3.6.1.4.1.53973.1.1.28.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups27InputLineIndex | 1.3.6.1.4.1.53973.1.1.28.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups27InputFrequency | 1.3.6.1.4.1.53973.1.1.28.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups27InputVoltage | 1.3.6.1.4.1.53973.1.1.28.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups27InputCurrent | 1.3.6.1.4.1.53973.1.1.28.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups27InputTruePower | 1.3.6.1.4.1.53973.1.1.28.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups27Output | 1.3.6.1.4.1.53973.1.1.28.1.4 | ||||||||||||
| Sups27OutputSource | 1.3.6.1.4.1.53973.1.1.28.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups27OutputFrequency | 1.3.6.1.4.1.53973.1.1.28.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups27OutputNumLines | 1.3.6.1.4.1.53973.1.1.28.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups27OutputTable | 1.3.6.1.4.1.53973.1.1.28.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups27OutputNumLines. | |||||||||||||
| Rups27OutputEntry | 1.3.6.1.4.1.53973.1.1.28.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups27OutputLineIndex | 1.3.6.1.4.1.53973.1.1.28.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups27OutputVoltage | 1.3.6.1.4.1.53973.1.1.28.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups27OutputCurrent | 1.3.6.1.4.1.53973.1.1.28.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups27OutputPower | 1.3.6.1.4.1.53973.1.1.28.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups27OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.28.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups27Bypass | 1.3.6.1.4.1.53973.1.1.28.1.5 | ||||||||||||
| Sups27BypassFrequency | 1.3.6.1.4.1.53973.1.1.28.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups27BypassNumLines | 1.3.6.1.4.1.53973.1.1.28.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups27BypassTable | 1.3.6.1.4.1.53973.1.1.28.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups27BypassNumLines. | |||||||||||||
| Rups27BypassEntry | 1.3.6.1.4.1.53973.1.1.28.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups27BypassLineIndex | 1.3.6.1.4.1.53973.1.1.28.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups27BypassVoltage | 1.3.6.1.4.1.53973.1.1.28.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups27BypassCurrent | 1.3.6.1.4.1.53973.1.1.28.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups27BypassPower | 1.3.6.1.4.1.53973.1.1.28.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups27Alarm | 1.3.6.1.4.1.53973.1.1.28.1.6 | ||||||||||||
| Sups27AlarmsPresent | 1.3.6.1.4.1.53973.1.1.28.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups27AlarmTable | 1.3.6.1.4.1.53973.1.1.28.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups27AlarmId equal to 1, and increments the value of ups27AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups27AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups27AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups27AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups27AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups27AlarmsPresent. | |||||||||||||
| Rups27AlarmEntry | 1.3.6.1.4.1.53973.1.1.28.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups27AlarmId | 1.3.6.1.4.1.53973.1.1.28.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups27AlarmDescr | 1.3.6.1.4.1.53973.1.1.28.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups27AlarmTime | 1.3.6.1.4.1.53973.1.1.28.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups27AlarmTime shall equal 0. | |||||||||||||
| Nups27WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.28.1.6.3 | ||||||||||||
| Nups27AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.28.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups27AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.28.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups27AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.28.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups27ConfigLowBattTime. | |||||||||||||
| Nups27AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.28.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups27AlarmTempBad | 1.3.6.1.4.1.53973.1.1.28.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups27AlarmInputBad | 1.3.6.1.4.1.53973.1.1.28.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups27AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.28.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups27AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.28.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups27AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.28.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups27AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.28.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups27AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.28.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups27AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.28.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups27AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.28.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups27AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.28.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups27AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.28.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups27AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.28.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups27AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.28.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups27AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.28.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups27AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.28.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups27AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.28.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups27AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.28.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups27AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.28.1.6.3.22 | ||||||||||||
node · current A ups27ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups27AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.28.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups27AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.28.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups27Test | 1.3.6.1.4.1.53973.1.1.28.1.7 | ||||||||||||
| Sups27TestId | 1.3.6.1.4.1.53973.1.1.28.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups27TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups27TestResultsSummary. Tests in progress may be aborted by setting the ups27TestId variable to ups27TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups27TestNoTestsInitiated is returned. | |||||||||||||
| Sups27TestSpinLock | 1.3.6.1.4.1.53973.1.1.28.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups27TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups27TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups27TestResultsSummary */
get (upsTestSpinLock, ups27TestResultsSummary,
ups27TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups27TestResultsSummary,
ups27TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups27TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups27TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups27TestResultsSummary | 1.3.6.1.4.1.53973.1.1.28.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups27TestId to ups27TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups27TestResultsDetail | 1.3.6.1.4.1.53973.1.1.28.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups27TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups27TestStartTime | 1.3.6.1.4.1.53973.1.1.28.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups27TestResultsSummary is noTestsInitiated(6), ups27TestStartTime has the value 0. | |||||||||||||
| Sups27TestElapsedTime | 1.3.6.1.4.1.53973.1.1.28.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups27TestResultsSummary is noTestsInitiated(6), ups27TestElapsedTime has the value 0. | |||||||||||||
| Nups27WellKnownTests | 1.3.6.1.4.1.53973.1.1.28.1.7.7 | ||||||||||||
| Nups27TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.28.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups27TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.28.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups27TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.28.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups27TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.28.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups27TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.28.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups27Control | 1.3.6.1.4.1.53973.1.1.28.1.8 | ||||||||||||
| Sups27ShutdownType | 1.3.6.1.4.1.53973.1.1.28.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups27ShutdownAfterDelay and ups27RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups27ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.28.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups27ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups27ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups27ShutdownType = output and the output is already off. When read, ups27ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups27ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups27StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.28.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups27StartupAfterDelay countdown or ups27RebootWithDuration countdown in progress. When read, ups27StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups27RebootWithDuration | 1.3.6.1.4.1.53973.1.1.28.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups27ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups27RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups27Traps | 1.3.6.1.4.1.53973.1.1.28.2 | ||||||||||||
| !ups27TrapOnBattery | 1.3.6.1.4.1.53973.1.1.28.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups27TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.28.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups27TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.28.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups27AlarmOnBattery and ups27AlarmTestInProgress.
| |||||||||||||
| !ups27TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.28.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups27AlarmTestInProgress.
| |||||||||||||
| Nups27Conformance | 1.3.6.1.4.1.53973.1.1.28.3 | ||||||||||||
| Nups27Compliances | 1.3.6.1.4.1.53973.1.1.28.3.1 | ||||||||||||
| Mups27SubsetCompliance | 1.3.6.1.4.1.53973.1.1.28.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups27BasicCompliance | 1.3.6.1.4.1.53973.1.1.28.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups27FullCompliance | 1.3.6.1.4.1.53973.1.1.28.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups27Groups | 1.3.6.1.4.1.53973.1.1.28.3.2 | ||||||||||||
| Nups27SubsetGroups | 1.3.6.1.4.1.53973.1.1.28.3.2.1 | ||||||||||||
| Gups27SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.1.1 | ||||||||||||
group · current The ups27SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups27SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups27SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.1.2 | ||||||||||||
group · current The ups27SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups27SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.1.3 | ||||||||||||
group · current The ups27SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups27SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.1.4 | ||||||||||||
group · current The ups27SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups27SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.1.6 | ||||||||||||
group · current The ups27SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups27SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.1.8 | ||||||||||||
group · current The ups27SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups27BasicGroups | 1.3.6.1.4.1.53973.1.1.28.3.2.2 | ||||||||||||
| Gups27BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.1 | ||||||||||||
group · current The ups27BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups27BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.2 | ||||||||||||
group · current The ups27BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups27BasicInputGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.3 | ||||||||||||
group · current The ups27BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups27BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.4 | ||||||||||||
group · current The ups27BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups27BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.5 | ||||||||||||
group · current The ups27BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups27BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.6 | ||||||||||||
group · current The ups27BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups27BasicTestGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.7 | ||||||||||||
group · current The ups27BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups27BasicControlGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.2.8 | ||||||||||||
group · current The ups27BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups27FullGroups | 1.3.6.1.4.1.53973.1.1.28.3.2.3 | ||||||||||||
| Gups27FullIdentGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.1 | ||||||||||||
group · current The ups27FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups27FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.2 | ||||||||||||
group · current The ups27FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups27FullInputGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.3 | ||||||||||||
group · current The ups27FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups27FullOutputGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.4 | ||||||||||||
group · current The ups27FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups27FullBypassGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.5 | ||||||||||||
group · current The ups27FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups27FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.6 | ||||||||||||
group · current The ups27FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups27FullTestGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.7 | ||||||||||||
group · current The ups27FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups27FullControlGroup | 1.3.6.1.4.1.53973.1.1.28.3.2.3.8 | ||||||||||||
group · current The ups27FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule28 | 1.3.6.1.4.1.53973.1.1.29 | ||||||||||||
| Nups28Objects | 1.3.6.1.4.1.53973.1.1.29.1 | ||||||||||||
| Nups28Ident | 1.3.6.1.4.1.53973.1.1.29.1.1 | ||||||||||||
| Sups28IdentManufacturer | 1.3.6.1.4.1.53973.1.1.29.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups28IdentModel | 1.3.6.1.4.1.53973.1.1.29.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups28IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.29.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups28IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups28IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.29.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups28IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups28IdentName | 1.3.6.1.4.1.53973.1.1.29.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups28IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.29.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups28Battery | 1.3.6.1.4.1.53973.1.1.29.1.2 | ||||||||||||
| Sups28BatteryStatus | 1.3.6.1.4.1.53973.1.1.29.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups28ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups28ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups28SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.29.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups28EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.29.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups28EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.29.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups28BatteryVoltage | 1.3.6.1.4.1.53973.1.1.29.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups28BatteryCurrent | 1.3.6.1.4.1.53973.1.1.29.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups28BatteryTemperature | 1.3.6.1.4.1.53973.1.1.29.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups28Input | 1.3.6.1.4.1.53973.1.1.29.1.3 | ||||||||||||
| Sups28InputLineBads | 1.3.6.1.4.1.53973.1.1.29.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups28InputNumLines | 1.3.6.1.4.1.53973.1.1.29.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups28InputTable | 1.3.6.1.4.1.53973.1.1.29.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups28InputNumLines. | |||||||||||||
| Rups28InputEntry | 1.3.6.1.4.1.53973.1.1.29.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups28InputLineIndex | 1.3.6.1.4.1.53973.1.1.29.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups28InputFrequency | 1.3.6.1.4.1.53973.1.1.29.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups28InputVoltage | 1.3.6.1.4.1.53973.1.1.29.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups28InputCurrent | 1.3.6.1.4.1.53973.1.1.29.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups28InputTruePower | 1.3.6.1.4.1.53973.1.1.29.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups28Output | 1.3.6.1.4.1.53973.1.1.29.1.4 | ||||||||||||
| Sups28OutputSource | 1.3.6.1.4.1.53973.1.1.29.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups28OutputFrequency | 1.3.6.1.4.1.53973.1.1.29.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups28OutputNumLines | 1.3.6.1.4.1.53973.1.1.29.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups28OutputTable | 1.3.6.1.4.1.53973.1.1.29.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups28OutputNumLines. | |||||||||||||
| Rups28OutputEntry | 1.3.6.1.4.1.53973.1.1.29.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups28OutputLineIndex | 1.3.6.1.4.1.53973.1.1.29.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups28OutputVoltage | 1.3.6.1.4.1.53973.1.1.29.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups28OutputCurrent | 1.3.6.1.4.1.53973.1.1.29.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups28OutputPower | 1.3.6.1.4.1.53973.1.1.29.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups28OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.29.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups28Bypass | 1.3.6.1.4.1.53973.1.1.29.1.5 | ||||||||||||
| Sups28BypassFrequency | 1.3.6.1.4.1.53973.1.1.29.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups28BypassNumLines | 1.3.6.1.4.1.53973.1.1.29.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups28BypassTable | 1.3.6.1.4.1.53973.1.1.29.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups28BypassNumLines. | |||||||||||||
| Rups28BypassEntry | 1.3.6.1.4.1.53973.1.1.29.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups28BypassLineIndex | 1.3.6.1.4.1.53973.1.1.29.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups28BypassVoltage | 1.3.6.1.4.1.53973.1.1.29.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups28BypassCurrent | 1.3.6.1.4.1.53973.1.1.29.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups28BypassPower | 1.3.6.1.4.1.53973.1.1.29.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups28Alarm | 1.3.6.1.4.1.53973.1.1.29.1.6 | ||||||||||||
| Sups28AlarmsPresent | 1.3.6.1.4.1.53973.1.1.29.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups28AlarmTable | 1.3.6.1.4.1.53973.1.1.29.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups28AlarmId equal to 1, and increments the value of ups28AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups28AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups28AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups28AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups28AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups28AlarmsPresent. | |||||||||||||
| Rups28AlarmEntry | 1.3.6.1.4.1.53973.1.1.29.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups28AlarmId | 1.3.6.1.4.1.53973.1.1.29.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups28AlarmDescr | 1.3.6.1.4.1.53973.1.1.29.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups28AlarmTime | 1.3.6.1.4.1.53973.1.1.29.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups28AlarmTime shall equal 0. | |||||||||||||
| Nups28WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.29.1.6.3 | ||||||||||||
| Nups28AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.29.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups28AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.29.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups28AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.29.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups28ConfigLowBattTime. | |||||||||||||
| Nups28AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.29.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups28AlarmTempBad | 1.3.6.1.4.1.53973.1.1.29.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups28AlarmInputBad | 1.3.6.1.4.1.53973.1.1.29.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups28AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.29.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups28AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.29.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups28AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.29.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups28AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.29.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups28AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.29.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups28AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.29.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups28AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.29.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups28AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.29.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups28AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.29.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups28AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.29.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups28AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.29.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups28AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.29.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups28AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.29.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups28AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.29.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups28AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.29.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups28AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.29.1.6.3.22 | ||||||||||||
node · current A ups28ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups28AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.29.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups28AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.29.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups28Test | 1.3.6.1.4.1.53973.1.1.29.1.7 | ||||||||||||
| Sups28TestId | 1.3.6.1.4.1.53973.1.1.29.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups28TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups28TestResultsSummary. Tests in progress may be aborted by setting the ups28TestId variable to ups28TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups28TestNoTestsInitiated is returned. | |||||||||||||
| Sups28TestSpinLock | 1.3.6.1.4.1.53973.1.1.29.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups28TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups28TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups28TestResultsSummary */
get (upsTestSpinLock, ups28TestResultsSummary,
ups28TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups28TestResultsSummary,
ups28TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups28TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups28TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups28TestResultsSummary | 1.3.6.1.4.1.53973.1.1.29.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups28TestId to ups28TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups28TestResultsDetail | 1.3.6.1.4.1.53973.1.1.29.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups28TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups28TestStartTime | 1.3.6.1.4.1.53973.1.1.29.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups28TestResultsSummary is noTestsInitiated(6), ups28TestStartTime has the value 0. | |||||||||||||
| Sups28TestElapsedTime | 1.3.6.1.4.1.53973.1.1.29.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups28TestResultsSummary is noTestsInitiated(6), ups28TestElapsedTime has the value 0. | |||||||||||||
| Nups28WellKnownTests | 1.3.6.1.4.1.53973.1.1.29.1.7.7 | ||||||||||||
| Nups28TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.29.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups28TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.29.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups28TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.29.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups28TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.29.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups28TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.29.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups28Control | 1.3.6.1.4.1.53973.1.1.29.1.8 | ||||||||||||
| Sups28ShutdownType | 1.3.6.1.4.1.53973.1.1.29.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups28ShutdownAfterDelay and ups28RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups28ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.29.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups28ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups28ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups28ShutdownType = output and the output is already off. When read, ups28ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups28ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups28StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.29.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups28StartupAfterDelay countdown or ups28RebootWithDuration countdown in progress. When read, ups28StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups28RebootWithDuration | 1.3.6.1.4.1.53973.1.1.29.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups28ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups28RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups28Traps | 1.3.6.1.4.1.53973.1.1.29.2 | ||||||||||||
| !ups28TrapOnBattery | 1.3.6.1.4.1.53973.1.1.29.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups28TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.29.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups28TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.29.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups28AlarmOnBattery and ups28AlarmTestInProgress.
| |||||||||||||
| !ups28TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.29.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups28AlarmTestInProgress.
| |||||||||||||
| Nups28Conformance | 1.3.6.1.4.1.53973.1.1.29.3 | ||||||||||||
| Nups28Compliances | 1.3.6.1.4.1.53973.1.1.29.3.1 | ||||||||||||
| Mups28SubsetCompliance | 1.3.6.1.4.1.53973.1.1.29.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups28BasicCompliance | 1.3.6.1.4.1.53973.1.1.29.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups28FullCompliance | 1.3.6.1.4.1.53973.1.1.29.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups28Groups | 1.3.6.1.4.1.53973.1.1.29.3.2 | ||||||||||||
| Nups28SubsetGroups | 1.3.6.1.4.1.53973.1.1.29.3.2.1 | ||||||||||||
| Gups28SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.1.1 | ||||||||||||
group · current The ups28SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups28SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups28SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.1.2 | ||||||||||||
group · current The ups28SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups28SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.1.3 | ||||||||||||
group · current The ups28SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups28SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.1.4 | ||||||||||||
group · current The ups28SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups28SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.1.6 | ||||||||||||
group · current The ups28SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups28SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.1.8 | ||||||||||||
group · current The ups28SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups28BasicGroups | 1.3.6.1.4.1.53973.1.1.29.3.2.2 | ||||||||||||
| Gups28BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.1 | ||||||||||||
group · current The ups28BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups28BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.2 | ||||||||||||
group · current The ups28BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups28BasicInputGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.3 | ||||||||||||
group · current The ups28BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups28BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.4 | ||||||||||||
group · current The ups28BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups28BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.5 | ||||||||||||
group · current The ups28BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups28BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.6 | ||||||||||||
group · current The ups28BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups28BasicTestGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.7 | ||||||||||||
group · current The ups28BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups28BasicControlGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.2.8 | ||||||||||||
group · current The ups28BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups28FullGroups | 1.3.6.1.4.1.53973.1.1.29.3.2.3 | ||||||||||||
| Gups28FullIdentGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.1 | ||||||||||||
group · current The ups28FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups28FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.2 | ||||||||||||
group · current The ups28FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups28FullInputGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.3 | ||||||||||||
group · current The ups28FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups28FullOutputGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.4 | ||||||||||||
group · current The ups28FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups28FullBypassGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.5 | ||||||||||||
group · current The ups28FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups28FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.6 | ||||||||||||
group · current The ups28FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups28FullTestGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.7 | ||||||||||||
group · current The ups28FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups28FullControlGroup | 1.3.6.1.4.1.53973.1.1.29.3.2.3.8 | ||||||||||||
group · current The ups28FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule29 | 1.3.6.1.4.1.53973.1.1.30 | ||||||||||||
| Nups29Objects | 1.3.6.1.4.1.53973.1.1.30.1 | ||||||||||||
| Nups29Ident | 1.3.6.1.4.1.53973.1.1.30.1.1 | ||||||||||||
| Sups29IdentManufacturer | 1.3.6.1.4.1.53973.1.1.30.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups29IdentModel | 1.3.6.1.4.1.53973.1.1.30.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups29IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.30.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups29IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups29IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.30.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups29IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups29IdentName | 1.3.6.1.4.1.53973.1.1.30.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups29IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.30.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups29Battery | 1.3.6.1.4.1.53973.1.1.30.1.2 | ||||||||||||
| Sups29BatteryStatus | 1.3.6.1.4.1.53973.1.1.30.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups29ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups29ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups29SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.30.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups29EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.30.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups29EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.30.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups29BatteryVoltage | 1.3.6.1.4.1.53973.1.1.30.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups29BatteryCurrent | 1.3.6.1.4.1.53973.1.1.30.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups29BatteryTemperature | 1.3.6.1.4.1.53973.1.1.30.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups29Input | 1.3.6.1.4.1.53973.1.1.30.1.3 | ||||||||||||
| Sups29InputLineBads | 1.3.6.1.4.1.53973.1.1.30.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups29InputNumLines | 1.3.6.1.4.1.53973.1.1.30.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups29InputTable | 1.3.6.1.4.1.53973.1.1.30.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups29InputNumLines. | |||||||||||||
| Rups29InputEntry | 1.3.6.1.4.1.53973.1.1.30.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups29InputLineIndex | 1.3.6.1.4.1.53973.1.1.30.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups29InputFrequency | 1.3.6.1.4.1.53973.1.1.30.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups29InputVoltage | 1.3.6.1.4.1.53973.1.1.30.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups29InputCurrent | 1.3.6.1.4.1.53973.1.1.30.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups29InputTruePower | 1.3.6.1.4.1.53973.1.1.30.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups29Output | 1.3.6.1.4.1.53973.1.1.30.1.4 | ||||||||||||
| Sups29OutputSource | 1.3.6.1.4.1.53973.1.1.30.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups29OutputFrequency | 1.3.6.1.4.1.53973.1.1.30.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups29OutputNumLines | 1.3.6.1.4.1.53973.1.1.30.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups29OutputTable | 1.3.6.1.4.1.53973.1.1.30.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups29OutputNumLines. | |||||||||||||
| Rups29OutputEntry | 1.3.6.1.4.1.53973.1.1.30.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups29OutputLineIndex | 1.3.6.1.4.1.53973.1.1.30.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups29OutputVoltage | 1.3.6.1.4.1.53973.1.1.30.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups29OutputCurrent | 1.3.6.1.4.1.53973.1.1.30.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups29OutputPower | 1.3.6.1.4.1.53973.1.1.30.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups29OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.30.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups29Bypass | 1.3.6.1.4.1.53973.1.1.30.1.5 | ||||||||||||
| Sups29BypassFrequency | 1.3.6.1.4.1.53973.1.1.30.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups29BypassNumLines | 1.3.6.1.4.1.53973.1.1.30.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups29BypassTable | 1.3.6.1.4.1.53973.1.1.30.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups29BypassNumLines. | |||||||||||||
| Rups29BypassEntry | 1.3.6.1.4.1.53973.1.1.30.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups29BypassLineIndex | 1.3.6.1.4.1.53973.1.1.30.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups29BypassVoltage | 1.3.6.1.4.1.53973.1.1.30.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups29BypassCurrent | 1.3.6.1.4.1.53973.1.1.30.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups29BypassPower | 1.3.6.1.4.1.53973.1.1.30.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups29Alarm | 1.3.6.1.4.1.53973.1.1.30.1.6 | ||||||||||||
| Sups29AlarmsPresent | 1.3.6.1.4.1.53973.1.1.30.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups29AlarmTable | 1.3.6.1.4.1.53973.1.1.30.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups29AlarmId equal to 1, and increments the value of ups29AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups29AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups29AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups29AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups29AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups29AlarmsPresent. | |||||||||||||
| Rups29AlarmEntry | 1.3.6.1.4.1.53973.1.1.30.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups29AlarmId | 1.3.6.1.4.1.53973.1.1.30.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups29AlarmDescr | 1.3.6.1.4.1.53973.1.1.30.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups29AlarmTime | 1.3.6.1.4.1.53973.1.1.30.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups29AlarmTime shall equal 0. | |||||||||||||
| Nups29WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.30.1.6.3 | ||||||||||||
| Nups29AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.30.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups29AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.30.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups29AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.30.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups29ConfigLowBattTime. | |||||||||||||
| Nups29AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.30.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups29AlarmTempBad | 1.3.6.1.4.1.53973.1.1.30.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups29AlarmInputBad | 1.3.6.1.4.1.53973.1.1.30.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups29AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.30.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups29AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.30.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups29AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.30.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups29AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.30.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups29AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.30.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups29AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.30.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups29AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.30.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups29AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.30.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups29AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.30.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups29AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.30.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups29AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.30.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups29AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.30.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups29AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.30.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups29AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.30.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups29AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.30.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups29AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.30.1.6.3.22 | ||||||||||||
node · current A ups29ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups29AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.30.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups29AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.30.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups29Test | 1.3.6.1.4.1.53973.1.1.30.1.7 | ||||||||||||
| Sups29TestId | 1.3.6.1.4.1.53973.1.1.30.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups29TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups29TestResultsSummary. Tests in progress may be aborted by setting the ups29TestId variable to ups29TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups29TestNoTestsInitiated is returned. | |||||||||||||
| Sups29TestSpinLock | 1.3.6.1.4.1.53973.1.1.30.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups29TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups29TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups29TestResultsSummary */
get (upsTestSpinLock, ups29TestResultsSummary,
ups29TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups29TestResultsSummary,
ups29TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups29TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups29TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups29TestResultsSummary | 1.3.6.1.4.1.53973.1.1.30.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups29TestId to ups29TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups29TestResultsDetail | 1.3.6.1.4.1.53973.1.1.30.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups29TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups29TestStartTime | 1.3.6.1.4.1.53973.1.1.30.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups29TestResultsSummary is noTestsInitiated(6), ups29TestStartTime has the value 0. | |||||||||||||
| Sups29TestElapsedTime | 1.3.6.1.4.1.53973.1.1.30.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups29TestResultsSummary is noTestsInitiated(6), ups29TestElapsedTime has the value 0. | |||||||||||||
| Nups29WellKnownTests | 1.3.6.1.4.1.53973.1.1.30.1.7.7 | ||||||||||||
| Nups29TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.30.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups29TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.30.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups29TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.30.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups29TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.30.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups29TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.30.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups29Control | 1.3.6.1.4.1.53973.1.1.30.1.8 | ||||||||||||
| Sups29ShutdownType | 1.3.6.1.4.1.53973.1.1.30.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups29ShutdownAfterDelay and ups29RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups29ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.30.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups29ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups29ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups29ShutdownType = output and the output is already off. When read, ups29ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups29ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups29StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.30.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups29StartupAfterDelay countdown or ups29RebootWithDuration countdown in progress. When read, ups29StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups29RebootWithDuration | 1.3.6.1.4.1.53973.1.1.30.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups29ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups29RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups29Traps | 1.3.6.1.4.1.53973.1.1.30.2 | ||||||||||||
| !ups29TrapOnBattery | 1.3.6.1.4.1.53973.1.1.30.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups29TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.30.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups29TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.30.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups29AlarmOnBattery and ups29AlarmTestInProgress.
| |||||||||||||
| !ups29TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.30.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups29AlarmTestInProgress.
| |||||||||||||
| Nups29Conformance | 1.3.6.1.4.1.53973.1.1.30.3 | ||||||||||||
| Nups29Compliances | 1.3.6.1.4.1.53973.1.1.30.3.1 | ||||||||||||
| Mups29SubsetCompliance | 1.3.6.1.4.1.53973.1.1.30.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups29BasicCompliance | 1.3.6.1.4.1.53973.1.1.30.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups29FullCompliance | 1.3.6.1.4.1.53973.1.1.30.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups29Groups | 1.3.6.1.4.1.53973.1.1.30.3.2 | ||||||||||||
| Nups29SubsetGroups | 1.3.6.1.4.1.53973.1.1.30.3.2.1 | ||||||||||||
| Gups29SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.1.1 | ||||||||||||
group · current The ups29SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups29SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups29SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.1.2 | ||||||||||||
group · current The ups29SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups29SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.1.3 | ||||||||||||
group · current The ups29SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups29SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.1.4 | ||||||||||||
group · current The ups29SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups29SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.1.6 | ||||||||||||
group · current The ups29SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups29SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.1.8 | ||||||||||||
group · current The ups29SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups29BasicGroups | 1.3.6.1.4.1.53973.1.1.30.3.2.2 | ||||||||||||
| Gups29BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.1 | ||||||||||||
group · current The ups29BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups29BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.2 | ||||||||||||
group · current The ups29BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups29BasicInputGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.3 | ||||||||||||
group · current The ups29BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups29BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.4 | ||||||||||||
group · current The ups29BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups29BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.5 | ||||||||||||
group · current The ups29BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups29BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.6 | ||||||||||||
group · current The ups29BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups29BasicTestGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.7 | ||||||||||||
group · current The ups29BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups29BasicControlGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.2.8 | ||||||||||||
group · current The ups29BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups29FullGroups | 1.3.6.1.4.1.53973.1.1.30.3.2.3 | ||||||||||||
| Gups29FullIdentGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.1 | ||||||||||||
group · current The ups29FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups29FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.2 | ||||||||||||
group · current The ups29FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups29FullInputGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.3 | ||||||||||||
group · current The ups29FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups29FullOutputGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.4 | ||||||||||||
group · current The ups29FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups29FullBypassGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.5 | ||||||||||||
group · current The ups29FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups29FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.6 | ||||||||||||
group · current The ups29FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups29FullTestGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.7 | ||||||||||||
group · current The ups29FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups29FullControlGroup | 1.3.6.1.4.1.53973.1.1.30.3.2.3.8 | ||||||||||||
group · current The ups29FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
| NupsModule30 | 1.3.6.1.4.1.53973.1.1.31 | ||||||||||||
| Nups30Objects | 1.3.6.1.4.1.53973.1.1.31.1 | ||||||||||||
| Nups30Ident | 1.3.6.1.4.1.53973.1.1.31.1.1 | ||||||||||||
| Sups30IdentManufacturer | 1.3.6.1.4.1.53973.1.1.31.1.1.1 | DisplayString (SIZE (0..31)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..31)) · read-only · current The name of the UPS manufacturer. | |||||||||||||
| Sups30IdentModel | 1.3.6.1.4.1.53973.1.1.31.1.1.2 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS Model designation. | |||||||||||||
| Sups30IdentUPSSoftwareVersion | 1.3.6.1.4.1.53973.1.1.31.1.1.3 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS firmware/software version(s). This variable may or may not have the same value as ups30IdentAgentSoftwareVersion in some implementations. | |||||||||||||
| Sups30IdentAgentSoftwareVersion | 1.3.6.1.4.1.53973.1.1.31.1.1.4 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current The UPS agent software version. This variable may or may not have the same value as ups30IdentUPSSoftwareVersion in some implementations. | |||||||||||||
| Sups30IdentName | 1.3.6.1.4.1.53973.1.1.31.1.1.5 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the UPS. This object should be set by the administrator. | |||||||||||||
| Sups30IdentAttachedDevices | 1.3.6.1.4.1.53973.1.1.31.1.1.6 | DisplayString (SIZE (0..63)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..63)) · read-only · current A string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator. | |||||||||||||
| Nups30Battery | 1.3.6.1.4.1.53973.1.1.31.1.2 | ||||||||||||
| Sups30BatteryStatus | 1.3.6.1.4.1.53973.1.1.31.1.2.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than ups30ConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to ups30ConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
| |||||||||||||
| Sups30SecondsOnBattery | 1.3.6.1.4.1.53973.1.1.31.1.2.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
| |||||||||||||
| Sups30EstimatedMinutesRemaining | 1.3.6.1.4.1.53973.1.1.31.1.2.3 | PositiveInteger | RO | ||||||||||
scalar · PositiveInteger · read-only · current An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.
| |||||||||||||
| Sups30EstimatedChargeRemaining | 1.3.6.1.4.1.53973.1.1.31.1.2.4 | Integer32 (0..100) | RO | ||||||||||
scalar · Integer32 (0..100) · read-only · current An estimate of the battery charge remaining expressed as a percent of full charge.
| |||||||||||||
| Sups30BatteryVoltage | 1.3.6.1.4.1.53973.1.1.31.1.2.5 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The magnitude of the present battery voltage.
| |||||||||||||
| Sups30BatteryCurrent | 1.3.6.1.4.1.53973.1.1.31.1.2.6 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The present battery current.
| |||||||||||||
| Sups30BatteryTemperature | 1.3.6.1.4.1.53973.1.1.31.1.2.7 | Integer32 | RO | ||||||||||
scalar · Integer32 · read-only · current The ambient temperature at or near the UPS Battery casing.
| |||||||||||||
| Nups30Input | 1.3.6.1.4.1.53973.1.1.31.1.3 | ||||||||||||
| Sups30InputLineBads | 1.3.6.1.4.1.53973.1.1.31.1.3.1 | Counter32 | RO | ||||||||||
scalar · Counter32 · read-only · current A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. | |||||||||||||
| Sups30InputNumLines | 1.3.6.1.4.1.53973.1.1.31.1.3.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of input lines utilized in this device. This variable indicates the number of rows in the input table. | |||||||||||||
| Tups30InputTable | 1.3.6.1.4.1.53973.1.1.31.1.3.3 | NA | |||||||||||
table · not-accessible · current A list of input table entries. The number of entries is given by the value of ups30InputNumLines. | |||||||||||||
| Rups30InputEntry | 1.3.6.1.4.1.53973.1.1.31.1.3.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular input line.
| |||||||||||||
| Cups30InputLineIndex | 1.3.6.1.4.1.53973.1.1.31.1.3.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The input line identifier. | |||||||||||||
| Cups30InputFrequency | 1.3.6.1.4.1.53973.1.1.31.1.3.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present input frequency.
| |||||||||||||
| Cups30InputVoltage | 1.3.6.1.4.1.53973.1.1.31.1.3.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input voltage.
| |||||||||||||
| Cups30InputCurrent | 1.3.6.1.4.1.53973.1.1.31.1.3.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input current.
| |||||||||||||
| Cups30InputTruePower | 1.3.6.1.4.1.53973.1.1.31.1.3.3.1.5 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The magnitude of the present input true power.
| |||||||||||||
| Nups30Output | 1.3.6.1.4.1.53973.1.1.31.1.4 | ||||||||||||
| Sups30OutputSource | 1.3.6.1.4.1.53973.1.1.31.1.4.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.
| |||||||||||||
| Sups30OutputFrequency | 1.3.6.1.4.1.53973.1.1.31.1.4.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present output frequency.
| |||||||||||||
| Sups30OutputNumLines | 1.3.6.1.4.1.53973.1.1.31.1.4.3 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of output lines utilized in this device. This variable indicates the number of rows in the output table. | |||||||||||||
| Tups30OutputTable | 1.3.6.1.4.1.53973.1.1.31.1.4.4 | NA | |||||||||||
table · not-accessible · current A list of output table entries. The number of entries is given by the value of ups30OutputNumLines. | |||||||||||||
| Rups30OutputEntry | 1.3.6.1.4.1.53973.1.1.31.1.4.4.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular output line.
| |||||||||||||
| Cups30OutputLineIndex | 1.3.6.1.4.1.53973.1.1.31.1.4.4.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The output line identifier. | |||||||||||||
| Cups30OutputVoltage | 1.3.6.1.4.1.53973.1.1.31.1.4.4.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output voltage.
| |||||||||||||
| Cups30OutputCurrent | 1.3.6.1.4.1.53973.1.1.31.1.4.4.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output current.
| |||||||||||||
| Cups30OutputPower | 1.3.6.1.4.1.53973.1.1.31.1.4.4.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present output true power.
| |||||||||||||
| Cups30OutputPercentLoad | 1.3.6.1.4.1.53973.1.1.31.1.4.4.1.5 | Integer32 (0..200) | RO | ||||||||||
column · Integer32 (0..200) · read-only · current The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.
| |||||||||||||
| Nups30Bypass | 1.3.6.1.4.1.53973.1.1.31.1.5 | ||||||||||||
| Sups30BypassFrequency | 1.3.6.1.4.1.53973.1.1.31.1.5.1 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The present bypass frequency.
| |||||||||||||
| Sups30BypassNumLines | 1.3.6.1.4.1.53973.1.1.31.1.5.2 | NonNegativeInteger | RO | ||||||||||
scalar · NonNegativeInteger · read-only · current The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. | |||||||||||||
| Tups30BypassTable | 1.3.6.1.4.1.53973.1.1.31.1.5.3 | NA | |||||||||||
table · not-accessible · current A list of bypass table entries. The number of entries is given by the value of ups30BypassNumLines. | |||||||||||||
| Rups30BypassEntry | 1.3.6.1.4.1.53973.1.1.31.1.5.3.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular bypass input.
| |||||||||||||
| Cups30BypassLineIndex | 1.3.6.1.4.1.53973.1.1.31.1.5.3.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current The bypass line identifier. | |||||||||||||
| Cups30BypassVoltage | 1.3.6.1.4.1.53973.1.1.31.1.5.3.1.2 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass voltage.
| |||||||||||||
| Cups30BypassCurrent | 1.3.6.1.4.1.53973.1.1.31.1.5.3.1.3 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present bypass current.
| |||||||||||||
| Cups30BypassPower | 1.3.6.1.4.1.53973.1.1.31.1.5.3.1.4 | NonNegativeInteger | RO | ||||||||||
column · NonNegativeInteger · read-only · current The present true power conveyed by the bypass.
| |||||||||||||
| Nups30Alarm | 1.3.6.1.4.1.53973.1.1.31.1.6 | ||||||||||||
| Sups30AlarmsPresent | 1.3.6.1.4.1.53973.1.1.31.1.6.1 | Gauge32 | RO | ||||||||||
scalar · Gauge32 · read-only · current The present number of active alarm conditions. | |||||||||||||
| Tups30AlarmTable | 1.3.6.1.4.1.53973.1.1.31.1.6.2 | NA | |||||||||||
table · not-accessible · current A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with ups30AlarmId equal to 1, and increments the value of ups30AlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of ups30AlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because ups30AlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), ups30AlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of ups30AlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of ups30AlarmsPresent. | |||||||||||||
| Rups30AlarmEntry | 1.3.6.1.4.1.53973.1.1.31.1.6.2.1 | NA | |||||||||||
row · not-accessible · current An entry containing information applicable to a particular alarm.
| |||||||||||||
| Cups30AlarmId | 1.3.6.1.4.1.53973.1.1.31.1.6.2.1.1 | PositiveInteger | NA | ||||||||||
column · PositiveInteger · not-accessible · current A unique identifier for an alarm condition. This value must remain constant. | |||||||||||||
| Cups30AlarmDescr | 1.3.6.1.4.1.53973.1.1.31.1.6.2.1.2 | AutonomousType | RO | ||||||||||
column · AutonomousType · read-only · current A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. | |||||||||||||
| Cups30AlarmTime | 1.3.6.1.4.1.53973.1.1.31.1.6.2.1.3 | TimeStamp | RO | ||||||||||
column · TimeStamp · read-only · current The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of ups30AlarmTime shall equal 0. | |||||||||||||
| Nups30WellKnownAlarms | 1.3.6.1.4.1.53973.1.1.31.1.6.3 | ||||||||||||
| Nups30AlarmBatteryBad | 1.3.6.1.4.1.53973.1.1.31.1.6.3.1 | ||||||||||||
node · current One or more batteries have been determined to require replacement. | |||||||||||||
| Nups30AlarmOnBattery | 1.3.6.1.4.1.53973.1.1.31.1.6.3.2 | ||||||||||||
node · current The UPS is drawing power from the batteries. | |||||||||||||
| Nups30AlarmLowBattery | 1.3.6.1.4.1.53973.1.1.31.1.6.3.3 | ||||||||||||
node · current The remaining battery run-time is less than or equal to ups30ConfigLowBattTime. | |||||||||||||
| Nups30AlarmDepletedBattery | 1.3.6.1.4.1.53973.1.1.31.1.6.3.4 | ||||||||||||
node · current The UPS will be unable to sustain the present load when and if the utility power is lost. | |||||||||||||
| Nups30AlarmTempBad | 1.3.6.1.4.1.53973.1.1.31.1.6.3.5 | ||||||||||||
node · current A temperature is out of tolerance. | |||||||||||||
| Nups30AlarmInputBad | 1.3.6.1.4.1.53973.1.1.31.1.6.3.6 | ||||||||||||
node · current An input condition is out of tolerance. | |||||||||||||
| Nups30AlarmOutputBad | 1.3.6.1.4.1.53973.1.1.31.1.6.3.7 | ||||||||||||
node · current An output condition (other than OutputOverload) is out of tolerance. | |||||||||||||
| Nups30AlarmOutputOverload | 1.3.6.1.4.1.53973.1.1.31.1.6.3.8 | ||||||||||||
node · current The output load exceeds the UPS output capacity. | |||||||||||||
| Nups30AlarmOnBypass | 1.3.6.1.4.1.53973.1.1.31.1.6.3.9 | ||||||||||||
node · current The Bypass is presently engaged on the UPS. | |||||||||||||
| Nups30AlarmBypassBad | 1.3.6.1.4.1.53973.1.1.31.1.6.3.10 | ||||||||||||
node · current The Bypass is out of tolerance. | |||||||||||||
| Nups30AlarmOutputOffAsRequested | 1.3.6.1.4.1.53973.1.1.31.1.6.3.11 | ||||||||||||
node · current The UPS has shutdown as requested, i.e., the output is off. | |||||||||||||
| Nups30AlarmUpsOffAsRequested | 1.3.6.1.4.1.53973.1.1.31.1.6.3.12 | ||||||||||||
node · current The entire UPS has shutdown as commanded. | |||||||||||||
| Nups30AlarmChargerFailed | 1.3.6.1.4.1.53973.1.1.31.1.6.3.13 | ||||||||||||
node · current An uncorrected problem has been detected within the UPS charger subsystem. | |||||||||||||
| Nups30AlarmUpsOutputOff | 1.3.6.1.4.1.53973.1.1.31.1.6.3.14 | ||||||||||||
node · current The output of the UPS is in the off state. | |||||||||||||
| Nups30AlarmUpsSystemOff | 1.3.6.1.4.1.53973.1.1.31.1.6.3.15 | ||||||||||||
node · current The UPS system is in the off state. | |||||||||||||
| Nups30AlarmFanFailure | 1.3.6.1.4.1.53973.1.1.31.1.6.3.16 | ||||||||||||
node · current The failure of one or more fans in the UPS has been detected. | |||||||||||||
| Nups30AlarmFuseFailure | 1.3.6.1.4.1.53973.1.1.31.1.6.3.17 | ||||||||||||
node · current The failure of one or more fuses has been detected. | |||||||||||||
| Nups30AlarmGeneralFault | 1.3.6.1.4.1.53973.1.1.31.1.6.3.18 | ||||||||||||
node · current A general fault in the UPS has been detected. | |||||||||||||
| Nups30AlarmDiagnosticTestFailed | 1.3.6.1.4.1.53973.1.1.31.1.6.3.19 | ||||||||||||
node · current The result of the last diagnostic test indicates a failure. | |||||||||||||
| Nups30AlarmCommunicationsLost | 1.3.6.1.4.1.53973.1.1.31.1.6.3.20 | ||||||||||||
node · current A problem has been encountered in the communications between the agent and the UPS. | |||||||||||||
| Nups30AlarmAwaitingPower | 1.3.6.1.4.1.53973.1.1.31.1.6.3.21 | ||||||||||||
node · current The UPS output is off and the UPS is awaiting the return of input power. | |||||||||||||
| Nups30AlarmShutdownPending | 1.3.6.1.4.1.53973.1.1.31.1.6.3.22 | ||||||||||||
node · current A ups30ShutdownAfterDelay countdown is underway. | |||||||||||||
| Nups30AlarmShutdownImminent | 1.3.6.1.4.1.53973.1.1.31.1.6.3.23 | ||||||||||||
node · current The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | |||||||||||||
| Nups30AlarmTestInProgress | 1.3.6.1.4.1.53973.1.1.31.1.6.3.24 | ||||||||||||
node · current A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | |||||||||||||
| Nups30Test | 1.3.6.1.4.1.53973.1.1.31.1.7 | ||||||||||||
| Sups30TestId | 1.3.6.1.4.1.53973.1.1.31.1.7.1 | OBJECT IDENTIFIER | RO | ||||||||||
scalar · OBJECT IDENTIFIER · read-only · current The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of ups30TestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. The status of the current or last test is maintained in ups30TestResultsSummary. Tests in progress may be aborted by setting the ups30TestId variable to ups30TestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has been run, in which case the well known value ups30TestNoTestsInitiated is returned. | |||||||||||||
| Sups30TestSpinLock | 1.3.6.1.4.1.53973.1.1.31.1.7.2 | TestAndIncr | RO | ||||||||||
scalar · TestAndIncr · read-only · current A spin lock on the test subsystem. The spinlock is
used as follows.
Before starting a test, a manager-station should make
sure that a test is not in progress as follows:
try_again:
get (upsTestSpinLock)
while (upsTestResultsSummary == inProgress) {
/* loop while a test is running for another
manager */
short delay
get (upsTestSpinLock)
}
lock_value = ups30TestSpinLock
/* no test in progress, start the test */
set (upsTestSpinLock = lock_value, ups30TestId =
requested_test)
if (error_index == 1) { /* (upsTestSpinLock
failed) */
/* if problem is not access control, then
some other manager slipped in ahead of us
*/
goto try_again
}
if (error_index == 2) { /* (upsTestId) */
/* cannot perform the test */
give up
}
/* test started ok */
/* wait for test completion by polling
ups30TestResultsSummary */
get (upsTestSpinLock, ups30TestResultsSummary,
ups30TestResultsDetail)
while (upsTestResultsSummary == inProgress) {
short delay
get (upsTestSpinLock, ups30TestResultsSummary,
ups30TestResultsDetail)
}
/* when test completes, retrieve any additional
test results */
/* if ups30TestSpinLock == lock_value + 1, then
these are our test */
/* results (as opposed to another manager's */
The initial value of ups30TestSpinLock at agent
initialization shall
be 1. | |||||||||||||
| Sups30TestResultsSummary | 1.3.6.1.4.1.53973.1.1.31.1.7.3 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of ups30TestId to ups30TestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.
| |||||||||||||
| Sups30TestResultsDetail | 1.3.6.1.4.1.53973.1.1.31.1.7.4 | DisplayString (SIZE (0..255)) | RO | ||||||||||
scalar · DisplayString (SIZE (0..255)) · read-only · current Additional information about ups30TestResultsSummary. If no additional information available, a zero length string is returned. | |||||||||||||
| Sups30TestStartTime | 1.3.6.1.4.1.53973.1.1.31.1.7.5 | TimeStamp | RO | ||||||||||
scalar · TimeStamp · read-only · current The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of ups30TestResultsSummary is noTestsInitiated(6), ups30TestStartTime has the value 0. | |||||||||||||
| Sups30TestElapsedTime | 1.3.6.1.4.1.53973.1.1.31.1.7.6 | TimeInterval | RO | ||||||||||
scalar · TimeInterval · read-only · current The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of ups30TestResultsSummary is noTestsInitiated(6), ups30TestElapsedTime has the value 0. | |||||||||||||
| Nups30WellKnownTests | 1.3.6.1.4.1.53973.1.1.31.1.7.7 | ||||||||||||
| Nups30TestNoTestsInitiated | 1.3.6.1.4.1.53973.1.1.31.1.7.7.1 | ||||||||||||
node · current No tests have been initiated and no test is in progress. | |||||||||||||
| Nups30TestAbortTestInProgress | 1.3.6.1.4.1.53973.1.1.31.1.7.7.2 | ||||||||||||
node · current The test in progress is to be aborted / the test in progress was aborted. | |||||||||||||
| Nups30TestGeneralSystemsTest | 1.3.6.1.4.1.53973.1.1.31.1.7.7.3 | ||||||||||||
node · current The manufacturer's standard test of UPS device systems. | |||||||||||||
| Nups30TestQuickBatteryTest | 1.3.6.1.4.1.53973.1.1.31.1.7.7.4 | ||||||||||||
node · current A test that is sufficient to determine if the battery needs replacement. | |||||||||||||
| Nups30TestDeepBatteryCalibration | 1.3.6.1.4.1.53973.1.1.31.1.7.7.5 | ||||||||||||
node · current The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. | |||||||||||||
| Nups30Control | 1.3.6.1.4.1.53973.1.1.31.1.8 | ||||||||||||
| Sups30ShutdownType | 1.3.6.1.4.1.53973.1.1.31.1.8.1 | INTEGER | RO | ||||||||||
scalar · INTEGER · read-only · current This object determines the nature of the action to be taken at the time when the countdown of the ups30ShutdownAfterDelay and ups30RebootWithDuration objects reaches zero. Setting this object to output(1) indicates that shutdown requests should cause only the output of the UPS to turn off. Setting this object to system(2) indicates that shutdown requests will cause the entire UPS system to turn off.
| |||||||||||||
| Sups30ShutdownAfterDelay | 1.3.6.1.4.1.53973.1.1.31.1.8.2 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups30ShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. That is, there is no additional action at that time if ups30ShutdownType = system and the system is already off. Similarly, there is no additional action at that time if ups30ShutdownType = output and the output is already off. When read, ups30ShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any ups30ShutdownAfterDelay already in effect.
| |||||||||||||
| Sups30StartupAfterDelay | 1.3.6.1.4.1.53973.1.1.31.1.8.3 | Integer32 (-1..2147483647) | RO | ||||||||||
scalar · Integer32 (-1..2147483647) · read-only · current Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any ups30StartupAfterDelay countdown or ups30RebootWithDuration countdown in progress. When read, ups30StartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
| |||||||||||||
| Sups30RebootWithDuration | 1.3.6.1.4.1.53973.1.1.31.1.8.4 | Integer32 (-1..300) | RO | ||||||||||
scalar · Integer32 (-1..300) · read-only · current Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of ups30ShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, ups30RebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
| |||||||||||||
| Nups30Traps | 1.3.6.1.4.1.53973.1.1.31.2 | ||||||||||||
| !ups30TrapOnBattery | 1.3.6.1.4.1.53973.1.1.31.2.1 | ||||||||||||
notification · current The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | |||||||||||||
| !ups30TrapTestCompleted | 1.3.6.1.4.1.53973.1.1.31.2.2 | ||||||||||||
notification · current This trap is sent upon completion of a UPS diagnostic test. | |||||||||||||
| !ups30TrapAlarmEntryAdded | 1.3.6.1.4.1.53973.1.1.31.2.3 | ||||||||||||
notification · current This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for ups30AlarmOnBattery and ups30AlarmTestInProgress.
| |||||||||||||
| !ups30TrapAlarmEntryRemoved | 1.3.6.1.4.1.53973.1.1.31.2.4 | ||||||||||||
notification · current This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for ups30AlarmTestInProgress.
| |||||||||||||
| Nups30Conformance | 1.3.6.1.4.1.53973.1.1.31.3 | ||||||||||||
| Nups30Compliances | 1.3.6.1.4.1.53973.1.1.31.3.1 | ||||||||||||
| Mups30SubsetCompliance | 1.3.6.1.4.1.53973.1.1.31.3.1.1 | ||||||||||||
compliance · current The compliance statement for UPSs that only support the two-contact communication protocol. | |||||||||||||
| Mups30BasicCompliance | 1.3.6.1.4.1.53973.1.1.31.3.1.2 | ||||||||||||
compliance · current The compliance statement for UPSs that support full-featured functions, such as control. | |||||||||||||
| Mups30FullCompliance | 1.3.6.1.4.1.53973.1.1.31.3.1.3 | ||||||||||||
compliance · current The compliance statement for UPSs that support advanced full-featured functions. | |||||||||||||
| Nups30Groups | 1.3.6.1.4.1.53973.1.1.31.3.2 | ||||||||||||
| Nups30SubsetGroups | 1.3.6.1.4.1.53973.1.1.31.3.2.1 | ||||||||||||
| Gups30SubsetIdentGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.1.1 | ||||||||||||
group · current The ups30SubsetIdentGroup defines objects which are common across all UPSs which meet subset compliance. Most devices which conform to the ups30SubsetIdentGroup will provide access to these objects via a proxy agent. If the proxy agent is compatible with multiple UPS types, configuration of the proxy agent will require specifying some of these values, either individually, or as a group (perhaps through a table lookup mechanism based on the UPS model number). | |||||||||||||
| Gups30SubsetBatteryGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.1.2 | ||||||||||||
group · current The ups30SubsetBatteryGroup defines the objects that are common to battery groups of two-contact UPSs. | |||||||||||||
| Gups30SubsetInputGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.1.3 | ||||||||||||
group · current The ups30SubsetInputGroup defines the objects that are common to the Input groups of two-contact UPSs.
| |||||||||||||
| Gups30SubsetOutputGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.1.4 | ||||||||||||
group · current The ups30SubsetOutputGroup defines the objects that are common to the Output groups of two-contact UPSs.
| |||||||||||||
| Gups30SubsetAlarmGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.1.6 | ||||||||||||
group · current The ups30SubsetAlarmGroup defines the objects that are common to the Alarm groups of two-contact UPSs. | |||||||||||||
| Gups30SubsetControlGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.1.8 | ||||||||||||
group · current The ups30SubsetControlGroup defines the objects that are common to the Control groups of two-contact UPSs. | |||||||||||||
| Nups30BasicGroups | 1.3.6.1.4.1.53973.1.1.31.3.2.2 | ||||||||||||
| Gups30BasicIdentGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.1 | ||||||||||||
group · current The ups30BasicIdentGroup defines objects which are common to the Ident group of compliant UPSs which support basic functions. | |||||||||||||
| Gups30BasicBatteryGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.2 | ||||||||||||
group · current The ups30BasicBatteryGroup defines the objects that are common to the battery groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups30BasicInputGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.3 | ||||||||||||
group · current The ups30BasicInputGroup defines the objects that are common to the Input groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups30BasicOutputGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.4 | ||||||||||||
group · current The ups30BasicOutputGroup defines the objects that are common to the Output groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups30BasicBypassGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.5 | ||||||||||||
group · current The ups30BasicBypassGroup defines the objects that are common to the Bypass groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups30BasicAlarmGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.6 | ||||||||||||
group · current The ups30BasicAlarmGroup defines the objects that are common to the Alarm groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups30BasicTestGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.7 | ||||||||||||
group · current The ups30BasicTestGroup defines the objects that are common to the Test groups of compliant UPSs which support basic functions. | |||||||||||||
| Gups30BasicControlGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.2.8 | ||||||||||||
group · current The ups30BasicControlGroup defines the objects that are common to the Control groups of compliant UPSs which support basic functions. | |||||||||||||
| Nups30FullGroups | 1.3.6.1.4.1.53973.1.1.31.3.2.3 | ||||||||||||
| Gups30FullIdentGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.1 | ||||||||||||
group · current The ups30FullIdentGroup defines objects which are common to the Ident group of fully compliant UPSs. | |||||||||||||
| Gups30FullBatteryGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.2 | ||||||||||||
group · current The ups30FullBatteryGroup defines the objects that are common to the battery groups of fully compliant UPSs. | |||||||||||||
| Gups30FullInputGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.3 | ||||||||||||
group · current The ups30FullInputGroup defines the objects that are common to the Input groups of fully compliant UPSs. | |||||||||||||
| Gups30FullOutputGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.4 | ||||||||||||
group · current The ups30FullOutputGroup defines the objects that are common to the Output groups of fully compliant UPSs. | |||||||||||||
| Gups30FullBypassGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.5 | ||||||||||||
group · current The ups30FullBypassGroup defines the objects that are common to the Bypass groups of fully compliant UPSs. | |||||||||||||
| Gups30FullAlarmGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.6 | ||||||||||||
group · current The ups30FullAlarmGroup defines the objects that are common to the Alarm groups of fully compliant UPSs. | |||||||||||||
| Gups30FullTestGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.7 | ||||||||||||
group · current The ups30FullTestGroup defines the objects that are common to the Test groups of fully compliant UPSs. | |||||||||||||
| Gups30FullControlGroup | 1.3.6.1.4.1.53973.1.1.31.3.2.3.8 | ||||||||||||
group · current The ups30FullControlGroup defines the objects that are common to the Control groups of fully compliant UPSs. | |||||||||||||
Textual conventions
NonNegativeIntegerInteger32 (0..2147483647)Display hint:
dThis data type is a non-negative value.
PositiveIntegerInteger32 (1..2147483647)Display hint:
dThis data type is a non-zero and non-negative value.
Traps / Notifications
- ups01TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.2.2.3 - ups01TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.2.2.4 - ups01TrapOnBattery
1.3.6.1.4.1.53973.1.1.2.2.1 - ups01TrapTestCompleted
1.3.6.1.4.1.53973.1.1.2.2.2 - ups02TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.3.2.3 - ups02TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.3.2.4 - ups02TrapOnBattery
1.3.6.1.4.1.53973.1.1.3.2.1 - ups02TrapTestCompleted
1.3.6.1.4.1.53973.1.1.3.2.2 - ups03TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.4.2.3 - ups03TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.4.2.4 - ups03TrapOnBattery
1.3.6.1.4.1.53973.1.1.4.2.1 - ups03TrapTestCompleted
1.3.6.1.4.1.53973.1.1.4.2.2 - ups04TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.5.2.3 - ups04TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.5.2.4 - ups04TrapOnBattery
1.3.6.1.4.1.53973.1.1.5.2.1 - ups04TrapTestCompleted
1.3.6.1.4.1.53973.1.1.5.2.2 - ups05TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.6.2.3 - ups05TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.6.2.4 - ups05TrapOnBattery
1.3.6.1.4.1.53973.1.1.6.2.1 - ups05TrapTestCompleted
1.3.6.1.4.1.53973.1.1.6.2.2 - ups06TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.7.2.3 - ups06TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.7.2.4 - ups06TrapOnBattery
1.3.6.1.4.1.53973.1.1.7.2.1 - ups06TrapTestCompleted
1.3.6.1.4.1.53973.1.1.7.2.2 - ups07TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.8.2.3 - ups07TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.8.2.4 - ups07TrapOnBattery
1.3.6.1.4.1.53973.1.1.8.2.1 - ups07TrapTestCompleted
1.3.6.1.4.1.53973.1.1.8.2.2 - ups08TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.9.2.3 - ups08TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.9.2.4 - ups08TrapOnBattery
1.3.6.1.4.1.53973.1.1.9.2.1 - ups08TrapTestCompleted
1.3.6.1.4.1.53973.1.1.9.2.2 - ups09TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.10.2.3 - ups09TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.10.2.4 - ups09TrapOnBattery
1.3.6.1.4.1.53973.1.1.10.2.1 - ups09TrapTestCompleted
1.3.6.1.4.1.53973.1.1.10.2.2 - ups10TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.11.2.3 - ups10TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.11.2.4 - ups10TrapOnBattery
1.3.6.1.4.1.53973.1.1.11.2.1 - ups10TrapTestCompleted
1.3.6.1.4.1.53973.1.1.11.2.2 - ups11TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.12.2.3 - ups11TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.12.2.4 - ups11TrapOnBattery
1.3.6.1.4.1.53973.1.1.12.2.1 - ups11TrapTestCompleted
1.3.6.1.4.1.53973.1.1.12.2.2 - ups12TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.13.2.3 - ups12TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.13.2.4 - ups12TrapOnBattery
1.3.6.1.4.1.53973.1.1.13.2.1 - ups12TrapTestCompleted
1.3.6.1.4.1.53973.1.1.13.2.2 - ups13TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.14.2.3 - ups13TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.14.2.4 - ups13TrapOnBattery
1.3.6.1.4.1.53973.1.1.14.2.1 - ups13TrapTestCompleted
1.3.6.1.4.1.53973.1.1.14.2.2 - ups14TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.15.2.3 - ups14TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.15.2.4 - ups14TrapOnBattery
1.3.6.1.4.1.53973.1.1.15.2.1 - ups14TrapTestCompleted
1.3.6.1.4.1.53973.1.1.15.2.2 - ups15TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.16.2.3 - ups15TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.16.2.4 - ups15TrapOnBattery
1.3.6.1.4.1.53973.1.1.16.2.1 - ups15TrapTestCompleted
1.3.6.1.4.1.53973.1.1.16.2.2 - ups16TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.17.2.3 - ups16TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.17.2.4 - ups16TrapOnBattery
1.3.6.1.4.1.53973.1.1.17.2.1 - ups16TrapTestCompleted
1.3.6.1.4.1.53973.1.1.17.2.2 - ups17TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.18.2.3 - ups17TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.18.2.4 - ups17TrapOnBattery
1.3.6.1.4.1.53973.1.1.18.2.1 - ups17TrapTestCompleted
1.3.6.1.4.1.53973.1.1.18.2.2 - ups18TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.19.2.3 - ups18TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.19.2.4 - ups18TrapOnBattery
1.3.6.1.4.1.53973.1.1.19.2.1 - ups18TrapTestCompleted
1.3.6.1.4.1.53973.1.1.19.2.2 - ups19TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.20.2.3 - ups19TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.20.2.4 - ups19TrapOnBattery
1.3.6.1.4.1.53973.1.1.20.2.1 - ups19TrapTestCompleted
1.3.6.1.4.1.53973.1.1.20.2.2 - ups20TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.21.2.3 - ups20TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.21.2.4 - ups20TrapOnBattery
1.3.6.1.4.1.53973.1.1.21.2.1 - ups20TrapTestCompleted
1.3.6.1.4.1.53973.1.1.21.2.2 - ups21TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.22.2.3 - ups21TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.22.2.4 - ups21TrapOnBattery
1.3.6.1.4.1.53973.1.1.22.2.1 - ups21TrapTestCompleted
1.3.6.1.4.1.53973.1.1.22.2.2 - ups22TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.23.2.3 - ups22TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.23.2.4 - ups22TrapOnBattery
1.3.6.1.4.1.53973.1.1.23.2.1 - ups22TrapTestCompleted
1.3.6.1.4.1.53973.1.1.23.2.2 - ups23TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.24.2.3 - ups23TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.24.2.4 - ups23TrapOnBattery
1.3.6.1.4.1.53973.1.1.24.2.1 - ups23TrapTestCompleted
1.3.6.1.4.1.53973.1.1.24.2.2 - ups24TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.25.2.3 - ups24TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.25.2.4 - ups24TrapOnBattery
1.3.6.1.4.1.53973.1.1.25.2.1 - ups24TrapTestCompleted
1.3.6.1.4.1.53973.1.1.25.2.2 - ups25TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.26.2.3 - ups25TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.26.2.4 - ups25TrapOnBattery
1.3.6.1.4.1.53973.1.1.26.2.1 - ups25TrapTestCompleted
1.3.6.1.4.1.53973.1.1.26.2.2 - ups26TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.27.2.3 - ups26TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.27.2.4 - ups26TrapOnBattery
1.3.6.1.4.1.53973.1.1.27.2.1 - ups26TrapTestCompleted
1.3.6.1.4.1.53973.1.1.27.2.2 - ups27TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.28.2.3 - ups27TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.28.2.4 - ups27TrapOnBattery
1.3.6.1.4.1.53973.1.1.28.2.1 - ups27TrapTestCompleted
1.3.6.1.4.1.53973.1.1.28.2.2 - ups28TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.29.2.3 - ups28TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.29.2.4 - ups28TrapOnBattery
1.3.6.1.4.1.53973.1.1.29.2.1 - ups28TrapTestCompleted
1.3.6.1.4.1.53973.1.1.29.2.2 - ups29TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.30.2.3 - ups29TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.30.2.4 - ups29TrapOnBattery
1.3.6.1.4.1.53973.1.1.30.2.1 - ups29TrapTestCompleted
1.3.6.1.4.1.53973.1.1.30.2.2 - ups30TrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.31.2.3 - ups30TrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.31.2.4 - ups30TrapOnBattery
1.3.6.1.4.1.53973.1.1.31.2.1 - ups30TrapTestCompleted
1.3.6.1.4.1.53973.1.1.31.2.2 - upsTrapAlarmEntryAdded
1.3.6.1.4.1.53973.1.1.1.2.3 - upsTrapAlarmEntryRemoved
1.3.6.1.4.1.53973.1.1.1.2.4 - upsTrapOnBattery
1.3.6.1.4.1.53973.1.1.1.2.1 - upsTrapTestCompleted
1.3.6.1.4.1.53973.1.1.1.2.2
Groups and compliance
- ups01BasicAlarmGroup
- ups01BasicBatteryGroup
- ups01BasicBypassGroup
- ups01BasicCompliance
- ups01BasicControlGroup
- ups01BasicIdentGroup
- ups01BasicInputGroup
- ups01BasicOutputGroup
- ups01BasicTestGroup
- ups01FullAlarmGroup
- ups01FullBatteryGroup
- ups01FullBypassGroup
- ups01FullCompliance
- ups01FullControlGroup
- ups01FullIdentGroup
- ups01FullInputGroup
- ups01FullOutputGroup
- ups01FullTestGroup
- ups01SubsetAlarmGroup
- ups01SubsetBatteryGroup
- ups01SubsetCompliance
- ups01SubsetControlGroup
- ups01SubsetIdentGroup
- ups01SubsetInputGroup
- ups01SubsetOutputGroup
- ups02BasicAlarmGroup
- ups02BasicBatteryGroup
- ups02BasicBypassGroup
- ups02BasicCompliance
- ups02BasicControlGroup
- ups02BasicIdentGroup
- ups02BasicInputGroup
- ups02BasicOutputGroup
- ups02BasicTestGroup
- ups02FullAlarmGroup
- ups02FullBatteryGroup
- ups02FullBypassGroup
- ups02FullCompliance
- ups02FullControlGroup
- ups02FullIdentGroup
- ups02FullInputGroup
- ups02FullOutputGroup
- ups02FullTestGroup
- ups02SubsetAlarmGroup
- ups02SubsetBatteryGroup
- ups02SubsetCompliance
- ups02SubsetControlGroup
- ups02SubsetIdentGroup
- ups02SubsetInputGroup
- ups02SubsetOutputGroup
- ups03BasicAlarmGroup
- ups03BasicBatteryGroup
- ups03BasicBypassGroup
- ups03BasicCompliance
- ups03BasicControlGroup
- ups03BasicIdentGroup
- ups03BasicInputGroup
- ups03BasicOutputGroup
- ups03BasicTestGroup
- ups03FullAlarmGroup
- ups03FullBatteryGroup
- ups03FullBypassGroup
- ups03FullCompliance
- ups03FullControlGroup
- ups03FullIdentGroup
- ups03FullInputGroup
- ups03FullOutputGroup
- ups03FullTestGroup
- ups03SubsetAlarmGroup
- ups03SubsetBatteryGroup
- ups03SubsetCompliance
- ups03SubsetControlGroup
- ups03SubsetIdentGroup
- ups03SubsetInputGroup
- ups03SubsetOutputGroup
- ups04BasicAlarmGroup
- ups04BasicBatteryGroup
- ups04BasicBypassGroup
- ups04BasicCompliance
- ups04BasicControlGroup
- ups04BasicIdentGroup
- ups04BasicInputGroup
- ups04BasicOutputGroup
- ups04BasicTestGroup
- ups04FullAlarmGroup
- ups04FullBatteryGroup
- ups04FullBypassGroup
- ups04FullCompliance
- ups04FullControlGroup
- ups04FullIdentGroup
- ups04FullInputGroup
- ups04FullOutputGroup
- ups04FullTestGroup
- ups04SubsetAlarmGroup
- ups04SubsetBatteryGroup
- ups04SubsetCompliance
- ups04SubsetControlGroup
- ups04SubsetIdentGroup
- ups04SubsetInputGroup
- ups04SubsetOutputGroup
- ups05BasicAlarmGroup
- ups05BasicBatteryGroup
- ups05BasicBypassGroup
- ups05BasicCompliance
- ups05BasicControlGroup
- ups05BasicIdentGroup
- ups05BasicInputGroup
- ups05BasicOutputGroup
- ups05BasicTestGroup
- ups05FullAlarmGroup
- ups05FullBatteryGroup
- ups05FullBypassGroup
- ups05FullCompliance
- ups05FullControlGroup
- ups05FullIdentGroup
- ups05FullInputGroup
- ups05FullOutputGroup
- ups05FullTestGroup
- ups05SubsetAlarmGroup
- ups05SubsetBatteryGroup
- ups05SubsetCompliance
- ups05SubsetControlGroup
- ups05SubsetIdentGroup
- ups05SubsetInputGroup
- ups05SubsetOutputGroup
- ups06BasicAlarmGroup
- ups06BasicBatteryGroup
- ups06BasicBypassGroup
- ups06BasicCompliance
- ups06BasicControlGroup
- ups06BasicIdentGroup
- ups06BasicInputGroup
- ups06BasicOutputGroup
- ups06BasicTestGroup
- ups06FullAlarmGroup
- ups06FullBatteryGroup
- ups06FullBypassGroup
- ups06FullCompliance
- ups06FullControlGroup
- ups06FullIdentGroup
- ups06FullInputGroup
- ups06FullOutputGroup
- ups06FullTestGroup
- ups06SubsetAlarmGroup
- ups06SubsetBatteryGroup
- ups06SubsetCompliance
- ups06SubsetControlGroup
- ups06SubsetIdentGroup
- ups06SubsetInputGroup
- ups06SubsetOutputGroup
- ups07BasicAlarmGroup
- ups07BasicBatteryGroup
- ups07BasicBypassGroup
- ups07BasicCompliance
- ups07BasicControlGroup
- ups07BasicIdentGroup
- ups07BasicInputGroup
- ups07BasicOutputGroup
- ups07BasicTestGroup
- ups07FullAlarmGroup
- ups07FullBatteryGroup
- ups07FullBypassGroup
- ups07FullCompliance
- ups07FullControlGroup
- ups07FullIdentGroup
- ups07FullInputGroup
- ups07FullOutputGroup
- ups07FullTestGroup
- ups07SubsetAlarmGroup
- ups07SubsetBatteryGroup
- ups07SubsetCompliance
- ups07SubsetControlGroup
- ups07SubsetIdentGroup
- ups07SubsetInputGroup
- ups07SubsetOutputGroup
- ups08BasicAlarmGroup
- ups08BasicBatteryGroup
- ups08BasicBypassGroup
- ups08BasicCompliance
- ups08BasicControlGroup
- ups08BasicIdentGroup
- ups08BasicInputGroup
- ups08BasicOutputGroup
- ups08BasicTestGroup
- ups08FullAlarmGroup
- ups08FullBatteryGroup
- ups08FullBypassGroup
- ups08FullCompliance
- ups08FullControlGroup
- ups08FullIdentGroup
- ups08FullInputGroup
- ups08FullOutputGroup
- ups08FullTestGroup
- ups08SubsetAlarmGroup
- ups08SubsetBatteryGroup
- ups08SubsetCompliance
- ups08SubsetControlGroup
- ups08SubsetIdentGroup
- ups08SubsetInputGroup
- ups08SubsetOutputGroup
- ups09BasicAlarmGroup
- ups09BasicBatteryGroup
- ups09BasicBypassGroup
- ups09BasicCompliance
- ups09BasicControlGroup
- ups09BasicIdentGroup
- ups09BasicInputGroup
- ups09BasicOutputGroup
- ups09BasicTestGroup
- ups09FullAlarmGroup
- ups09FullBatteryGroup
- ups09FullBypassGroup
- ups09FullCompliance
- ups09FullControlGroup
- ups09FullIdentGroup
- ups09FullInputGroup
- ups09FullOutputGroup
- ups09FullTestGroup
- ups09SubsetAlarmGroup
- ups09SubsetBatteryGroup
- ups09SubsetCompliance
- ups09SubsetControlGroup
- ups09SubsetIdentGroup
- ups09SubsetInputGroup
- ups09SubsetOutputGroup
- ups10BasicAlarmGroup
- ups10BasicBatteryGroup
- ups10BasicBypassGroup
- ups10BasicCompliance
- ups10BasicControlGroup
- ups10BasicIdentGroup
- ups10BasicInputGroup
- ups10BasicOutputGroup
- ups10BasicTestGroup
- ups10FullAlarmGroup
- ups10FullBatteryGroup
- ups10FullBypassGroup
- ups10FullCompliance
- ups10FullControlGroup
- ups10FullIdentGroup
- ups10FullInputGroup
- ups10FullOutputGroup
- ups10FullTestGroup
- ups10SubsetAlarmGroup
- ups10SubsetBatteryGroup
- ups10SubsetCompliance
- ups10SubsetControlGroup
- ups10SubsetIdentGroup
- ups10SubsetInputGroup
- ups10SubsetOutputGroup
- ups11BasicAlarmGroup
- ups11BasicBatteryGroup
- ups11BasicBypassGroup
- ups11BasicCompliance
- ups11BasicControlGroup
- ups11BasicIdentGroup
- ups11BasicInputGroup
- ups11BasicOutputGroup
- ups11BasicTestGroup
- ups11FullAlarmGroup
- ups11FullBatteryGroup
- ups11FullBypassGroup
- ups11FullCompliance
- ups11FullControlGroup
- ups11FullIdentGroup
- ups11FullInputGroup
- ups11FullOutputGroup
- ups11FullTestGroup
- ups11SubsetAlarmGroup
- ups11SubsetBatteryGroup
- ups11SubsetCompliance
- ups11SubsetControlGroup
- ups11SubsetIdentGroup
- ups11SubsetInputGroup
- ups11SubsetOutputGroup
- ups12BasicAlarmGroup
- ups12BasicBatteryGroup
- ups12BasicBypassGroup
- ups12BasicCompliance
- ups12BasicControlGroup
- ups12BasicIdentGroup
- ups12BasicInputGroup
- ups12BasicOutputGroup
- ups12BasicTestGroup
- ups12FullAlarmGroup
- ups12FullBatteryGroup
- ups12FullBypassGroup
- ups12FullCompliance
- ups12FullControlGroup
- ups12FullIdentGroup
- ups12FullInputGroup
- ups12FullOutputGroup
- ups12FullTestGroup
- ups12SubsetAlarmGroup
- ups12SubsetBatteryGroup
- ups12SubsetCompliance
- ups12SubsetControlGroup
- ups12SubsetIdentGroup
- ups12SubsetInputGroup
- ups12SubsetOutputGroup
- ups13BasicAlarmGroup
- ups13BasicBatteryGroup
- ups13BasicBypassGroup
- ups13BasicCompliance
- ups13BasicControlGroup
- ups13BasicIdentGroup
- ups13BasicInputGroup
- ups13BasicOutputGroup
- ups13BasicTestGroup
- ups13FullAlarmGroup
- ups13FullBatteryGroup
- ups13FullBypassGroup
- ups13FullCompliance
- ups13FullControlGroup
- ups13FullIdentGroup
- ups13FullInputGroup
- ups13FullOutputGroup
- ups13FullTestGroup
- ups13SubsetAlarmGroup
- ups13SubsetBatteryGroup
- ups13SubsetCompliance
- ups13SubsetControlGroup
- ups13SubsetIdentGroup
- ups13SubsetInputGroup
- ups13SubsetOutputGroup
- ups14BasicAlarmGroup
- ups14BasicBatteryGroup
- ups14BasicBypassGroup
- ups14BasicCompliance
- ups14BasicControlGroup
- ups14BasicIdentGroup
- ups14BasicInputGroup
- ups14BasicOutputGroup
- ups14BasicTestGroup
- ups14FullAlarmGroup
- ups14FullBatteryGroup
- ups14FullBypassGroup
- ups14FullCompliance
- ups14FullControlGroup
- ups14FullIdentGroup
- ups14FullInputGroup
- ups14FullOutputGroup
- ups14FullTestGroup
- ups14SubsetAlarmGroup
- ups14SubsetBatteryGroup
- ups14SubsetCompliance
- ups14SubsetControlGroup
- ups14SubsetIdentGroup
- ups14SubsetInputGroup
- ups14SubsetOutputGroup
- ups15BasicAlarmGroup
- ups15BasicBatteryGroup
- ups15BasicBypassGroup
- ups15BasicCompliance
- ups15BasicControlGroup
- ups15BasicIdentGroup
- ups15BasicInputGroup
- ups15BasicOutputGroup
- ups15BasicTestGroup
- ups15FullAlarmGroup
- ups15FullBatteryGroup
- ups15FullBypassGroup
- ups15FullCompliance
- ups15FullControlGroup
- ups15FullIdentGroup
- ups15FullInputGroup
- ups15FullOutputGroup
- ups15FullTestGroup
- ups15SubsetAlarmGroup
- ups15SubsetBatteryGroup
- ups15SubsetCompliance
- ups15SubsetControlGroup
- ups15SubsetIdentGroup
- ups15SubsetInputGroup
- ups15SubsetOutputGroup
- ups16BasicAlarmGroup
- ups16BasicBatteryGroup
- ups16BasicBypassGroup
- ups16BasicCompliance
- ups16BasicControlGroup
- ups16BasicIdentGroup
- ups16BasicInputGroup
- ups16BasicOutputGroup
- ups16BasicTestGroup
- ups16FullAlarmGroup
- ups16FullBatteryGroup
- ups16FullBypassGroup
- ups16FullCompliance
- ups16FullControlGroup
- ups16FullIdentGroup
- ups16FullInputGroup
- ups16FullOutputGroup
- ups16FullTestGroup
- ups16SubsetAlarmGroup
- ups16SubsetBatteryGroup
- ups16SubsetCompliance
- ups16SubsetControlGroup
- ups16SubsetIdentGroup
- ups16SubsetInputGroup
- ups16SubsetOutputGroup
- ups17BasicAlarmGroup
- ups17BasicBatteryGroup
- ups17BasicBypassGroup
- ups17BasicCompliance
- ups17BasicControlGroup
- ups17BasicIdentGroup
- ups17BasicInputGroup
- ups17BasicOutputGroup
- ups17BasicTestGroup
- ups17FullAlarmGroup
- ups17FullBatteryGroup
- ups17FullBypassGroup
- ups17FullCompliance
- ups17FullControlGroup
- ups17FullIdentGroup
- ups17FullInputGroup
- ups17FullOutputGroup
- ups17FullTestGroup
- ups17SubsetAlarmGroup
- ups17SubsetBatteryGroup
- ups17SubsetCompliance
- ups17SubsetControlGroup
- ups17SubsetIdentGroup
- ups17SubsetInputGroup
- ups17SubsetOutputGroup
- ups18BasicAlarmGroup
- ups18BasicBatteryGroup
- ups18BasicBypassGroup
- ups18BasicCompliance
- ups18BasicControlGroup
- ups18BasicIdentGroup
- ups18BasicInputGroup
- ups18BasicOutputGroup
- ups18BasicTestGroup
- ups18FullAlarmGroup
- ups18FullBatteryGroup
- ups18FullBypassGroup
- ups18FullCompliance
- ups18FullControlGroup
- ups18FullIdentGroup
- ups18FullInputGroup
- ups18FullOutputGroup
- ups18FullTestGroup
- ups18SubsetAlarmGroup
- ups18SubsetBatteryGroup
- ups18SubsetCompliance
- ups18SubsetControlGroup
- ups18SubsetIdentGroup
- ups18SubsetInputGroup
- ups18SubsetOutputGroup
- ups19BasicAlarmGroup
- ups19BasicBatteryGroup
- ups19BasicBypassGroup
- ups19BasicCompliance
- ups19BasicControlGroup
- ups19BasicIdentGroup
- ups19BasicInputGroup
- ups19BasicOutputGroup
- ups19BasicTestGroup
- ups19FullAlarmGroup
- ups19FullBatteryGroup
- ups19FullBypassGroup
- ups19FullCompliance
- ups19FullControlGroup
- ups19FullIdentGroup
- ups19FullInputGroup
- ups19FullOutputGroup
- ups19FullTestGroup
- ups19SubsetAlarmGroup
- ups19SubsetBatteryGroup
- ups19SubsetCompliance
- ups19SubsetControlGroup
- ups19SubsetIdentGroup
- ups19SubsetInputGroup
- ups19SubsetOutputGroup
- ups20BasicAlarmGroup
- ups20BasicBatteryGroup
- ups20BasicBypassGroup
- ups20BasicCompliance
- ups20BasicControlGroup
- ups20BasicIdentGroup
- ups20BasicInputGroup
- ups20BasicOutputGroup
- ups20BasicTestGroup
- ups20FullAlarmGroup
- ups20FullBatteryGroup
- ups20FullBypassGroup
- ups20FullCompliance
- ups20FullControlGroup
- ups20FullIdentGroup
- ups20FullInputGroup
- ups20FullOutputGroup
- ups20FullTestGroup
- ups20SubsetAlarmGroup
- ups20SubsetBatteryGroup
- ups20SubsetCompliance
- ups20SubsetControlGroup
- ups20SubsetIdentGroup
- ups20SubsetInputGroup
- ups20SubsetOutputGroup
- ups21BasicAlarmGroup
- ups21BasicBatteryGroup
- ups21BasicBypassGroup
- ups21BasicCompliance
- ups21BasicControlGroup
- ups21BasicIdentGroup
- ups21BasicInputGroup
- ups21BasicOutputGroup
- ups21BasicTestGroup
- ups21FullAlarmGroup
- ups21FullBatteryGroup
- ups21FullBypassGroup
- ups21FullCompliance
- ups21FullControlGroup
- ups21FullIdentGroup
- ups21FullInputGroup
- ups21FullOutputGroup
- ups21FullTestGroup
- ups21SubsetAlarmGroup
- ups21SubsetBatteryGroup
- ups21SubsetCompliance
- ups21SubsetControlGroup
- ups21SubsetIdentGroup
- ups21SubsetInputGroup
- ups21SubsetOutputGroup
- ups22BasicAlarmGroup
- ups22BasicBatteryGroup
- ups22BasicBypassGroup
- ups22BasicCompliance
- ups22BasicControlGroup
- ups22BasicIdentGroup
- ups22BasicInputGroup
- ups22BasicOutputGroup
- ups22BasicTestGroup
- ups22FullAlarmGroup
- ups22FullBatteryGroup
- ups22FullBypassGroup
- ups22FullCompliance
- ups22FullControlGroup
- ups22FullIdentGroup
- ups22FullInputGroup
- ups22FullOutputGroup
- ups22FullTestGroup
- ups22SubsetAlarmGroup
- ups22SubsetBatteryGroup
- ups22SubsetCompliance
- ups22SubsetControlGroup
- ups22SubsetIdentGroup
- ups22SubsetInputGroup
- ups22SubsetOutputGroup
- ups23BasicAlarmGroup
- ups23BasicBatteryGroup
- ups23BasicBypassGroup
- ups23BasicCompliance
- ups23BasicControlGroup
- ups23BasicIdentGroup
- ups23BasicInputGroup
- ups23BasicOutputGroup
- ups23BasicTestGroup
- ups23FullAlarmGroup
- ups23FullBatteryGroup
- ups23FullBypassGroup
- ups23FullCompliance
- ups23FullControlGroup
- ups23FullIdentGroup
- ups23FullInputGroup
- ups23FullOutputGroup
- ups23FullTestGroup
- ups23SubsetAlarmGroup
- ups23SubsetBatteryGroup
- ups23SubsetCompliance
- ups23SubsetControlGroup
- ups23SubsetIdentGroup
- ups23SubsetInputGroup
- ups23SubsetOutputGroup
- ups24BasicAlarmGroup
- ups24BasicBatteryGroup
- ups24BasicBypassGroup
- ups24BasicCompliance
- ups24BasicControlGroup
- ups24BasicIdentGroup
- ups24BasicInputGroup
- ups24BasicOutputGroup
- ups24BasicTestGroup
- ups24FullAlarmGroup
- ups24FullBatteryGroup
- ups24FullBypassGroup
- ups24FullCompliance
- ups24FullControlGroup
- ups24FullIdentGroup
- ups24FullInputGroup
- ups24FullOutputGroup
- ups24FullTestGroup
- ups24SubsetAlarmGroup
- ups24SubsetBatteryGroup
- ups24SubsetCompliance
- ups24SubsetControlGroup
- ups24SubsetIdentGroup
- ups24SubsetInputGroup
- ups24SubsetOutputGroup
- ups25BasicAlarmGroup
- ups25BasicBatteryGroup
- ups25BasicBypassGroup
- ups25BasicCompliance
- ups25BasicControlGroup
- ups25BasicIdentGroup
- ups25BasicInputGroup
- ups25BasicOutputGroup
- ups25BasicTestGroup
- ups25FullAlarmGroup
- ups25FullBatteryGroup
- ups25FullBypassGroup
- ups25FullCompliance
- ups25FullControlGroup
- ups25FullIdentGroup
- ups25FullInputGroup
- ups25FullOutputGroup
- ups25FullTestGroup
- ups25SubsetAlarmGroup
- ups25SubsetBatteryGroup
- ups25SubsetCompliance
- ups25SubsetControlGroup
- ups25SubsetIdentGroup
- ups25SubsetInputGroup
- ups25SubsetOutputGroup
- ups26BasicAlarmGroup
- ups26BasicBatteryGroup
- ups26BasicBypassGroup
- ups26BasicCompliance
- ups26BasicControlGroup
- ups26BasicIdentGroup
- ups26BasicInputGroup
- ups26BasicOutputGroup
- ups26BasicTestGroup
- ups26FullAlarmGroup
- ups26FullBatteryGroup
- ups26FullBypassGroup
- ups26FullCompliance
- ups26FullControlGroup
- ups26FullIdentGroup
- ups26FullInputGroup
- ups26FullOutputGroup
- ups26FullTestGroup
- ups26SubsetAlarmGroup
- ups26SubsetBatteryGroup
- ups26SubsetCompliance
- ups26SubsetControlGroup
- ups26SubsetIdentGroup
- ups26SubsetInputGroup
- ups26SubsetOutputGroup
- ups27BasicAlarmGroup
- ups27BasicBatteryGroup
- ups27BasicBypassGroup
- ups27BasicCompliance
- ups27BasicControlGroup
- ups27BasicIdentGroup
- ups27BasicInputGroup
- ups27BasicOutputGroup
- ups27BasicTestGroup
- ups27FullAlarmGroup
- ups27FullBatteryGroup
- ups27FullBypassGroup
- ups27FullCompliance
- ups27FullControlGroup
- ups27FullIdentGroup
- ups27FullInputGroup
- ups27FullOutputGroup
- ups27FullTestGroup
- ups27SubsetAlarmGroup
- ups27SubsetBatteryGroup
- ups27SubsetCompliance
- ups27SubsetControlGroup
- ups27SubsetIdentGroup
- ups27SubsetInputGroup
- ups27SubsetOutputGroup
- ups28BasicAlarmGroup
- ups28BasicBatteryGroup
- ups28BasicBypassGroup
- ups28BasicCompliance
- ups28BasicControlGroup
- ups28BasicIdentGroup
- ups28BasicInputGroup
- ups28BasicOutputGroup
- ups28BasicTestGroup
- ups28FullAlarmGroup
- ups28FullBatteryGroup
- ups28FullBypassGroup
- ups28FullCompliance
- ups28FullControlGroup
- ups28FullIdentGroup
- ups28FullInputGroup
- ups28FullOutputGroup
- ups28FullTestGroup
- ups28SubsetAlarmGroup
- ups28SubsetBatteryGroup
- ups28SubsetCompliance
- ups28SubsetControlGroup
- ups28SubsetIdentGroup
- ups28SubsetInputGroup
- ups28SubsetOutputGroup
- ups29BasicAlarmGroup
- ups29BasicBatteryGroup
- ups29BasicBypassGroup
- ups29BasicCompliance
- ups29BasicControlGroup
- ups29BasicIdentGroup
- ups29BasicInputGroup
- ups29BasicOutputGroup
- ups29BasicTestGroup
- ups29FullAlarmGroup
- ups29FullBatteryGroup
- ups29FullBypassGroup
- ups29FullCompliance
- ups29FullControlGroup
- ups29FullIdentGroup
- ups29FullInputGroup
- ups29FullOutputGroup
- ups29FullTestGroup
- ups29SubsetAlarmGroup
- ups29SubsetBatteryGroup
- ups29SubsetCompliance
- ups29SubsetControlGroup
- ups29SubsetIdentGroup
- ups29SubsetInputGroup
- ups29SubsetOutputGroup
- ups30BasicAlarmGroup
- ups30BasicBatteryGroup
- ups30BasicBypassGroup
- ups30BasicCompliance
- ups30BasicControlGroup
- ups30BasicIdentGroup
- ups30BasicInputGroup
- ups30BasicOutputGroup
- ups30BasicTestGroup
- ups30FullAlarmGroup
- ups30FullBatteryGroup
- ups30FullBypassGroup
- ups30FullCompliance
- ups30FullControlGroup
- ups30FullIdentGroup
- ups30FullInputGroup
- ups30FullOutputGroup
- ups30FullTestGroup
- ups30SubsetAlarmGroup
- ups30SubsetBatteryGroup
- ups30SubsetCompliance
- ups30SubsetControlGroup
- ups30SubsetIdentGroup
- ups30SubsetInputGroup
- ups30SubsetOutputGroup
- upsBasicAlarmGroup
- upsBasicBatteryGroup
- upsBasicBypassGroup
- upsBasicCompliance
- upsBasicControlGroup
- upsBasicIdentGroup
- upsBasicInputGroup
- upsBasicOutputGroup
- upsBasicTestGroup
- upsFullAlarmGroup
- upsFullBatteryGroup
- upsFullBypassGroup
- upsFullCompliance
- upsFullControlGroup
- upsFullIdentGroup
- upsFullInputGroup
- upsFullOutputGroup
- upsFullTestGroup
- upsSubsetAlarmGroup
- upsSubsetBatteryGroup
- upsSubsetCompliance
- upsSubsetControlGroup
- upsSubsetIdentGroup
- upsSubsetInputGroup
- upsSubsetOutputGroup