MIB Browser

SFLOW-MIB

sFlow.org
The MIB module for managing the generation and transportation
of sFlow data records.
Organization
sFlow.org
Root OID
1.3.6.1.4.1.14706.1
Last updated
Objects
33
Source
Show full MIB
snmptranslate -m SFLOW-MIB -Tp
snmpwalk -v2c -c <community> -m SFLOW-MIB <host> 1.3.6.1.4.1.14706.1

Imports

INET-ADDRESS-MIBInetAddress, InetAddressType
RMON-MIBOwnerString
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatusExample
IsFlowMIB1.3.6.1.4.1.14706.1
NsFlowAgent1.3.6.1.4.1.14706.1.1
SsFlowVersion1.3.6.1.4.1.14706.1.1.1SnmpAdminStringRO1.3;Vitesse;
SsFlowAgentAddressType1.3.6.1.4.1.14706.1.1.2InetAddressTypeRO1
SsFlowAgentAddress1.3.6.1.4.1.14706.1.1.3InetAddressRO7f:00:00:01
TsFlowRcvrTable1.3.6.1.4.1.14706.1.1.4NA
RsFlowRcvrEntry1.3.6.1.4.1.14706.1.1.4.1NA
CsFlowRcvrIndex1.3.6.1.4.1.14706.1.1.4.1.1Integer32 (1..65535)NA
CsFlowRcvrOwner1.3.6.1.4.1.14706.1.1.4.1.2OwnerStringRW
CsFlowRcvrTimeout1.3.6.1.4.1.14706.1.1.4.1.3Integer32RW0
CsFlowRcvrMaximumDatagramSize1.3.6.1.4.1.14706.1.1.4.1.4Integer32RW1400
CsFlowRcvrAddressType1.3.6.1.4.1.14706.1.1.4.1.5InetAddressTypeRW1
CsFlowRcvrAddress1.3.6.1.4.1.14706.1.1.4.1.6InetAddressRW00:00:00:00
CsFlowRcvrPort1.3.6.1.4.1.14706.1.1.4.1.7Integer32RW6343
CsFlowRcvrDatagramVersion1.3.6.1.4.1.14706.1.1.4.1.8Integer32RW5
TsFlowFsTable1.3.6.1.4.1.14706.1.1.5NA
RsFlowFsEntry1.3.6.1.4.1.14706.1.1.5.1NA
CsFlowFsDataSource1.3.6.1.4.1.14706.1.1.5.1.1SFlowDataSourceNA
CsFlowFsInstance1.3.6.1.4.1.14706.1.1.5.1.2SFlowInstanceNA
CsFlowFsReceiver1.3.6.1.4.1.14706.1.1.5.1.3SFlowReceiverRW0
CsFlowFsPacketSamplingRate1.3.6.1.4.1.14706.1.1.5.1.4Integer32RW0
CsFlowFsMaximumHeaderSize1.3.6.1.4.1.14706.1.1.5.1.5Integer32RW128
TsFlowCpTable1.3.6.1.4.1.14706.1.1.6NA
RsFlowCpEntry1.3.6.1.4.1.14706.1.1.6.1NA
CsFlowCpDataSource1.3.6.1.4.1.14706.1.1.6.1.1SFlowDataSourceNA
CsFlowCpInstance1.3.6.1.4.1.14706.1.1.6.1.2SFlowInstanceNA
CsFlowCpReceiver1.3.6.1.4.1.14706.1.1.6.1.3SFlowReceiverRW0
CsFlowCpInterval1.3.6.1.4.1.14706.1.1.6.1.4Integer32RW0
NsFlowMIBConformance1.3.6.1.4.1.14706.1.2
NsFlowMIBGroups1.3.6.1.4.1.14706.1.2.1
GsFlowAgentGroup1.3.6.1.4.1.14706.1.2.1.1
NsFlowMIBCompliances1.3.6.1.4.1.14706.1.2.2
MsFlowCompliance1.3.6.1.4.1.14706.1.2.2.1

Textual conventions

SFlowDataSource OBJECT IDENTIFIER
Identifies a source of sFlow data.

The following data source types are currently defined:

- ifIndex.<I>
SFlowDataSources of this traditional form are called
'port-based'. Ideally the sampling entity will perform
sampling on all flows originating from or destined to
the specified interface. However, if the switch architecture
only allows input or output sampling then the sampling agent
is permitted to only sample input flows input or output flows.
Each packet must only be considered once for sampling,
irrespective of the number of ports it will be forwarded to.
Note: Port 0 is used to indicate that all ports on the device
      are represented by a single data source.
      - sFlowFsPacketSamplingRate applies to all ports on the
        device capable of packet sampling.

- smonVlanDataSource.<V>
An SFlowDataSource of this form refers to a 'Packet-based VLAN'
and is called a 'VLAN-based' dataSource. <V> is the VLAN
ID as defined by the IEEE 802.1Q standard. The
value is between 1 and 4094 inclusive, and it represents
an 802.1Q VLAN-ID with global scope within a given
bridged domain.
Sampling is performed on all packets received that are part
of the specified VLAN (no matter which port they arrived on).
Each packet will only be considered once for sampling,
irrespective of the number of ports it will be forwarded to.

- entPhysicalEntry.<N>
An SFlowDataSource of this form refers to a physical entity
within the agent (e.g. entPhysicalClass = backplane(4)) and
is called an 'entity-based' dataSource. Sampling is performed
on all packets entering the resource (e.g. If the backplane
is being sampled, all packets transmitted onto the backplane
will be considered as single candidates for sampling
irrespective of the number of ports they ultimately reach).

Note: Since each SFlowDataSource operates independently a
      packet that crosses multiple DataSources may generate
      multiple flow records.
SFlowInstance Integer32 (1..65535)
If more than one sFlow sampler is available for this
SFlowDataSource then individual samplers are distinguished
using the SFlowInstance variable. The value of
SFlowInstance ranges from 1..n where n is the number of
samplers associated with this SFlowDataSource.

Note: Each sFlow sampler instance must operate
      independently of all other instances. Setting
      an attribute of one sampler must not alter the
      the behavior and settings of other sampler
      instances.
SFlowReceiver Integer32
Identify the sFlow receiver associated with this resource.

A value of zero indicates that this resource is available.
If non-zero the value must correspond to a valid, active
sFlowRcvrIndex.

If the value is currently zero it may be set to any
active entry in the sFlowRcvrTable. If the value is
not zero then a set to anything other than zero or
its current value will result in an SNMP error (bad value).

Setting to zero frees the resource and returns all the
values in this entry to their default values.

If an entry in the sFlowRcvrTable expires, either
because the sFlowRcvrOwner is set to the empty
string or because the sFlowRcvrTimeout reaches zero, then
the agent must mark all associated resources as available
(by setting the associated SFlowReceiver entry to zero)
and all values in these records must be restored to their
default values.

This mechanism provides no enforcement and relies on the
cooperation of management entities in order to ensure that
competition for a resource is fairly resolved. A management
entity should not make any changes to a resource
without first aquiring it by successfully writing its
sFlowRcvrIndex value as the SFlowReceiver for the resource.

Groups and compliance

Used by