MIB Browser

IEEE8021-TC-MIB

Standards (IEEE)
Textual conventions used throughout the various IEEE 802.1 MIB
modules.

Unless otherwise indicated, the references in this MIB
module are to IEEE Std 802.1Q-2022.

Copyright (C) IEEE (2022).
This version of this MIB module is part of IEEE Std 802.1Q;
see that standard for full legal notices.
Organization
IEEE 802.1 Working Group
Root OID
1.3.111.2.802.1.1.1
Last updated
Objects
2
Source
Show full MIB
snmptranslate -m IEEE8021-TC-MIB -Tp
snmpwalk -v2c -c <community> -m IEEE8021-TC-MIB <host> 1.3.111.2.802.1.1.1

Imports

SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIBits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, org
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

OID tree

NameOIDTypeAccessStatus
Nieee802dot1mibs1.3.111.2.802.1.1
Iieee8021TcMib1.3.111.2.802.1.1.1

Textual conventions

IEEE8021BridgePortNumber Unsigned32 (1..65535)

Display hint: d

An integer that uniquely identifies a Bridge Port, as
specified in 17.3.2.2.
This value is used within the spanning tree
protocol to identify this port to neighbor Bridges.
IEEE8021BridgePortNumberOrZero Unsigned32 (0..65535)

Display hint: d

An integer that uniquely identifies a Bridge Port. The value
0 means no port number, and this must be clarified in the
DESCRIPTION clause of any object defined using this
TEXTUAL-CONVENTION.
IEEE8021BridgePortType INTEGER

customerBackbonePort(6) customerEdgePort(5) customerNetworkPort(4) customerVlanPort(2) dBridgePort(8) none(1) providerNetworkPort(3) remoteCustomerAccessPort(9) stationFacingBridgePort(10) uplinkAccessPort(11) uplinkRelayPort(12) virtualInstancePort(7)

A port type.  The possible port types are:

customerVlanPort(2) - Indicates a port is a
    C-tag-aware port of an enterprise VLAN-aware Bridge.

providerNetworkPort(3) - Indicates a port is an S-tag-
    aware port of a Provider Bridge or Backbone Edge
    Bridge used for connections within a PBN or PBBN.

customerNetworkPort(4) - Indicates a port is an S-tag-
    aware port of a Provider Bridge or Backbone Edge
    Bridge used for connections to the exterior of a
    PBN or PBBN.

customerEdgePort(5) - Indicates a port is a C-tag-
    aware port of a Provider Bridge used for connections
    to the exterior of a PBN or PBBN.

customerBackbonePort(6) - Indicates a port is a I-tag-
    aware port of a Backbone Edge Bridge's B-component.

virtualInstancePort(7) - Indicates a port is a virtual
    S-tag-aware port within a Backbone Edge Bridge's
    I-component that is responsible for handling
    S-tagged traffic for a specific backbone service
    instance.

dBridgePort(8) - Indicates a port is a VLAN-unaware
    member of an IEEE 802.1D Bridge.

remoteCustomerAccessPort (9) - Indicates a port is an
    S-tag-aware port of a Provider Bridge used for
    connections to remote customer interface LANs
    through another PBN.

stationFacingBridgePort (10) - Indicates a port of a
    Bridge that supports the EVB status parameters
    (40.4) with an EVBMode parameter value of
    EVB Bridge.

uplinkAccessPort (11) - Indicates a port on a
    Port-mapping S-VLAN component that connects an EVB
    Bridge with an EVB station.

uplinkRelayPort (12) - Indicates a port of an edge relay
    that supports the EVB status parameters (40.4)
    with an EVBMode parameter value of EVB station.
IEEE8021MstIdentifier Unsigned32 (1..4094)

Display hint: d

In an MSTP Bridge, an MSTID, i.e., a value used to identify
a spanning tree (or MST) instance.  In the PBB-TE environment
the value 4094 is used to identify VIDs managed by the PBB-TE
procedures.
IEEE8021PbbComponentIdentifier Unsigned32 (1..4294967295)

Display hint: d

The component identifier is used to distinguish between the
multiple virtual Bridge instances within a PB or PBB.  Each
virtual Bridge instance is called a component.  In simple
situations where there is only a single component the default
value is 1.  The component is identified by a component
identifier unique within the BEB and by a MAC address unique
within the PBBN.  Each component is associated with a Backbone
Edge Bridge (BEB) Configuration managed object.
IEEE8021PbbComponentIdentifierOrZero Unsigned32 (0 | 1..4294967295)

Display hint: d

The component identifier is used to distinguish between the
multiple virtual Bridge instances within a PB or PBB.  In simple
situations where there is only a single component the default
value is 1.  The component is identified by a component
identifier unique within the BEB and by a MAC address unique
within the PBBN.  Each component is associated with a Backbone
Edge Bridge (BEB) Configuration managed object.

The special value '0' means 'no component identifier'.  When
this TC is used as the SYNTAX of an object, that object must
specify the exact meaning for this value.
IEEE8021PbbIngressEgress Bits

egress(1) ingress(0)

A 2 bit selector that determines if frames on this VIP may
ingress to the PBBN but not egress the PBBN, egress to the
PBBN but not ingress the PBBN, or both ingress and egress
the PBBN.
IEEE8021PbbServiceIdentifier Unsigned32 (256..16777214)

Display hint: d

The service instance identifier is used at the Customer
Backbone Port of a PBB to distinguish a service instance
(Local-SID). If the Local-SID field is supported, it is
used to perform a bidirectional 1:1 mapping between the
Backbone I-SID and the Local-SID. If the Local-SID field
is not supported, the Local-SID value is the same as the
Backbone I-SID value.
IEEE8021PbbServiceIdentifierOrUnassigned Unsigned32 (1 | 256..16777214)

Display hint: d

The service instance identifier is used at the Customer
Backbone Port of a PBB to distinguish a service instance
(Local-SID). If the Local-SID field is supported, it is
used to perform a bidirectional 1:1 mapping between the
Backbone I-SID and the Local-SID. If the Local-SID field
is not supported, the Local-SID value is the same as the
Backbone I-SID value.

The special value of 1 indicates an unassigned I-SID.
IEEE8021PbbTeEsp OCTET STRING (SIZE (14))
This textual convention is used to represent the logical
components that constitute the 3-tuple that identifies an
Ethernet Switched Path.  The 3-tuple consists of a
destination MAC address, a source MAC address and a VID.
Bytes (1..6) of this textual convention contain the
ESP-MAC-DA, bytes (7..12) contain the ESP-MAC-SA, and bytes
(13..14) contain the ESP-VID.
IEEE8021PbbTeProtectionGroupActiveRequests INTEGER

fs(3) loP(2) manualSwitchToProtection(6) manualSwitchToWorking(7) noRequest(1) pSFH(4) wSFH(5)

This textual convention is used to represent the status of
active requests within a protection group.
IEEE8021PbbTeProtectionGroupConfigAdmin INTEGER

clear(1) forceSwitch(3) lockOutProtection(2) manualSwitchToProtection(4) manualSwitchToWorking(5)

This textual convention is used to represent administrative
commands that can be issued to a protection group.  The value
noAdmin(1) is used to indicate that no administrative action
is to be performed.
IEEE8021PbbTeProtectionGroupId Unsigned32 (1..429467295)

Display hint: d

The PbbTeProtectionGroupId identifier is used to distinguish
protection group instances present in the B Component of
an IB-BEB.
IEEE8021PbbTeTSidId Unsigned32 (1..42947295)

Display hint: d

This textual convention is used to represent an identifier
that refers to a TE Service Instance.  Note that, internally
a TE-SID is implementation dependent.  This textual convention
defines the external representation of TE-SID values.
IEEE8021PortAcceptableFrameTypes INTEGER

admitAll(1) admitTagged(3) admitUntaggedAndPriority(2)

Acceptable frame types on a port.
IEEE8021PriorityCodePoint INTEGER

codePoint5p3d(4) codePoint6p2d(3) codePoint7p1d(2) codePoint8p0d(1)

Bridge ports may encode or decode the PCP value of the
frames that traverse the port. This textual convention
names the possible encoding and decoding schemes that
the port may use.  The priority and drop_eligible
parameters are encoded in the Priority Code Point (PCP)
field of the VLAN tag using the Priority Code Point
Encoding Table for the Port, and they are decoded from
the PCP using the Priority Code Point Decoding Table.
IEEE8021PriorityValue Unsigned32 (0..7)

Display hint: d

An IEEE 802.1Q user priority value.
IEEE8021ServiceSelectorType INTEGER

group-isid(6) ieeeReserved(7) isid(2) path-tesid(5) segid(4) tesid(3) vlanId(1)

A value that represents a type (and thereby the format)
of a IEEE8021ServiceSelectorValue.  The value can be one of
the following:

ieeeReserved(0)   Reserved for definition by IEEE 802.1
                  recommend to not use zero unless
                  absolutely needed.
vlanId(1)         12-Bit identifier as described in IEEE Std 802.1Q.
isid(2)           24-Bit identifier as described in IEEE Std 802.1ah.
tesid(3)          32 Bit identifier as described below.
segid(4)          32 Bit identifier as described below.
path-tesid(5)     32 Bit identifier as described below.
group-isid(6)     24 Bit identifier as described below.
ieeeReserved(7)  Reserved for definition by IEEE Std 802.1

To support future extensions, the IEEE8021ServiceSelectorType
textual convention SHOULD NOT be subtyped in object type
definitions.  It MAY be subtyped in compliance statements in
order to require only a subset of these address types for a
compliant implementation.

The tesid is used as a service selector for MAs that are present
in Bridges that implement PBB-TE functionality.  A selector of
this type is interpreted as a 32 bit unsigned value of type
IEEE8021PbbTeTSidId.  This type is used to index the
ieee8021PbbTeTeSiEspTable to find the ESPs that comprise the TE
Service Instance named by this TE-SID value.

The segid is used as a service selector for MAs that are present
in Bridges that implement IPS functionality.  A selector of
this type is interpreted as a 32 bit unsigned value of type
IEEE8021TeipsSegid.  This type is used to index the
Ieee8021TeipsSegTable to find the SMPs that comprise the
Infrastructure Segment named by this segid value.

The path-tesid is used as a service selector for SPBM path MAs.
A selector of this type is interpreted as a 32 bit unsigned value
corresponding to the MA index dot1agCfmMaIndex. This type is used
to index the dot1agCfmMepSpbmEspTable to find the ESPs that
comprise the SPBM path associated with an SPBM path MA.

The group-isid is used as a service selector for SPBM group MAs.
A selector of this type is interpreted as a 24 bit unsigned value
corresponding to the I-SID associated with an SPBM group MA.

Implementations MUST ensure that IEEE8021ServiceSelectorType
objects and any dependent objects (e.g.,
IEEE8021ServiceSelectorValue objects) are consistent.  An
inconsistentValue error MUST be generated if an attempt to
change an IEEE8021ServiceSelectorType object would, for
example, lead to an undefined IEEE8021ServiceSelectorValue value.
IEEE8021ServiceSelectorValue Unsigned32 (1..4294967295)

Display hint: d

An integer that uniquely identifies a generic MAC Service.
Examples of service selectors are a VLAN-ID (IEEE 802.1Q)
and an I-SID (IEEE Std 802.1ah).

An IEEE8021ServiceSelectorValue value is always interpreted
within the context of an IEEE8021ServiceSelectorType value.
Every usage of the IEEE8021ServiceSelectorValue textual
convention is required to specify the
IEEE8021ServiceSelectorType object that provides the context.
It is suggested that the IEEE8021ServiceSelectorType object
be logically registered before the object(s) that use the
IEEE8021ServiceSelectorValue textual convention, if they
appear in the same logical row.

The value of an IEEE8021ServiceSelectorValue object must
always be consistent with the value of the associated
IEEE8021ServiceSelectorType object.  Attempts to set an
IEEE8021ServiceSelectorValue object to a value inconsistent
with the associated IEEE8021ServiceSelectorType must fail
with an inconsistentValue error.

Note that a MIB object that is defined using this
TEXTUAL-CONVENTION SHOULD clarify the
maximum value (i.e., 4094, for a VLAN ID).
IEEE8021ServiceSelectorValueOrNone Unsigned32 (0 | 1..4294967295)

Display hint: d

An integer that uniquely identifies a generic MAC Service,
or none.  Examples of service selectors are a VLAN-ID
(IEEE 802.1Q) and an I-SID (IEEE Std 802.1ah).

An IEEE8021ServiceSelectorValueOrNone value is always
interpreted within the context of an
IEEE8021ServiceSelectorType value.  Every usage of the
IEEE8021ServiceSelectorValueOrNone textual convention is
required to specify the IEEE8021ServiceSelectorType object
that provides the context.  It is suggested that the
IEEE8021ServiceSelectorType object be logically registered
before the object(s) that use the
IEEE8021ServiceSelectorValueOrNone textual convention, if
they appear in the same logical row.

The value of an IEEE8021ServiceSelectorValueOrNone object
must always be consistent with the value of the associated
IEEE8021ServiceSelectorType object.  Attempts to set an
IEEE8021ServiceSelectorValueOrNone object to a value
inconsistent with the associated
IEEE8021ServiceSelectorType must fail with an
inconsistentValue error.

The special value of zero is used to indicate that no
service selector is present or used.  This can be used in
any situation where an object or a table entry MUST either
refer to a specific service, or not make a selection.

Note that a MIB object that is defined using this
TEXTUAL-CONVENTION SHOULD clarify the meaning of
'no service' (i.e., the special value 0), as well as the
maximum value (i.e., 4094, for a VLAN ID).
IEEE8021TeipsIpgConfigActiveRequests INTEGER

fs(3) loP(2) manualSwitchToProtection(6) manualSwitchToWorking(7) noRequest(1) pSFH(4) wSFH(5)

This textual convention is used to represent the status of
active requests within an IPG.
IEEE8021TeipsIpgConfigAdmin INTEGER

clear(1) forceSwitch(3) lockOutProtection(2) manualSwitchToProtection(4) manualSwitchToWorking(5)

This textual convention is used to represent administrative
commands that can be issued to an IPG.  The value
clear(1) is used to indicate that no administrative action
is to be performed.
IEEE8021TeipsIpgid Unsigned32 (1..429467295)

Display hint: d

The TEIPS IPG identifier is used to distinguish
IPG instances present in a PBB.
IEEE8021TeipsSegid Unsigned32 (1..42947295)

Display hint: d

This textual convention is used to represent an
identifier that refers to an Infrastructure Segment.
Note that, internally a SEG-ID implementation
dependent.  This textual convention defines the
external representation of SEG-ID values.
IEEE8021TeipsSmpid OCTET STRING (SIZE (14))
This textual convention is used to represent the logical
components that constitute the 3-tuple that identifies a
Segment Monitoring Path (SMP).  The 3-tuple consists of a
destination MAC address, a source MAC address and a VID.
Bytes (1..6) of this textual convention contain the
SMP-MAC-DA, bytes (7..12) contain the SMP-MAC-SA, and bytes
(13..14) contain the SMP-VID.
IEEE8021VlanIndex Unsigned32 (1..4094 | 4096..4294967295)

Display hint: d

A value used to index per-VLAN tables: values of 0 and
4095 are not permitted.  If the value is between 1 and
4094 inclusive, it represents an IEEE 802.1Q VLAN-ID with
global scope within a given bridged domain (see VlanId
textual convention).  If the value is greater than 4095,
then it represents a VLAN with scope local to the
particular agent, i.e., one without a global VLAN-ID
assigned to it.  Such VLANs are outside the scope of
IEEE 802.1Q, but it is convenient to be able to manage them
in the same way using this MIB.
IEEE8021VlanIndexOrWildcard Unsigned32 (1..4294967295)

Display hint: d

A value used to index per-VLAN tables.  The value 0 is not
permitted, while the value 4095 represents a 'wildcard'
value.  An object whose SYNTAX is IEEE8021VlanIndexOrWildcard
must specify in its DESCRIPTION the specific meaning of the
wildcard value.  If the value is between 1 and
4094 inclusive, it represents an IEEE 802.1Q VLAN-ID with
global scope within a given bridged domain (see VlanId
textual convention).  If the value is greater than 4095,
then it represents a VLAN with scope local to the
particular agent, i.e., one without a global VLAN-ID
assigned to it.  Such VLANs are outside the scope of
IEEE 802.1Q, but it is convenient to be able to manage them
in the same way using this MIB.

Used by