IANA-MAU-MIB
Standards (IETF)This MIB module defines dot3MauType OBJECT-IDENTITIES and IANAifMauListBits, IANAifMauMediaAvailable, IANAifMauAutoNegCapBits, and IANAifJackType TEXTUAL-CONVENTIONs, specifying enumerated values of the ifMauTypeListBits, ifMauMediaAvailable / rpMauMediaAvailable, ifMauAutoNegCapabilityBits / ifMauAutoNegCapAdvertisedBits / ifMauAutoNegCapReceivedBits and ifJackType / rpJackType objects respectively, defined in the MAU-MIB. It is intended that each new MAU type, Media Availability state, Auto Negotiation capability and/or Jack type defined by the IEEE 802.3 working group and approved for publication in a revision of IEEE Std 802.3 will be added to this MIB module, provided that it is suitable for being managed by the base objects in the MAU-MIB. An Expert Review, as defined in RFC 2434 [RFC2434], is REQUIRED for such additions. The following reference is used throughout this MIB module: [IEEE802.3] refers to IEEE Std 802.3-2022: 'IEEE Standard for Ethernet'. This reference should be updated as appropriate when new MAU types, Media Availability states, Auto Negotiation capabilities, and/or Jack types are added to this MIB module. Copyright (C) The IETF Trust (2007). The initial version of this MIB module was published in RFC 4836; for full legal notices see the RFC itself. Supplementary information may be available at: http://www.ietf.org/copyrights/ianamib.html
snmptranslate -m IANA-MAU-MIB -Tpsnmpwalk -v2c -c <community> -m IANA-MAU-MIB <host> 1.3.6.1.2.1.154Imports
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
|---|---|
| SNMPv2-SMI | Bits, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, mib-2 |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
OID tree
| Name | OID | Type | Access | Status |
|---|---|---|---|---|
| Ndot3MauType | 1.3.6.1.2.1.26.4 | |||
| Ndot3MauTypeAUI | 1.3.6.1.2.1.26.4.1 | |||
node · current no internal MAU, view from AUI | ||||
| Ndot3MauType10Base5 | 1.3.6.1.2.1.26.4.2 | |||
node · current thick coax MAU | ||||
| Ndot3MauTypeFoirl | 1.3.6.1.2.1.26.4.3 | |||
node · current FOIRL MAU | ||||
| Ndot3MauType10Base2 | 1.3.6.1.2.1.26.4.4 | |||
node · current thin coax MAU | ||||
| Ndot3MauType10BaseT | 1.3.6.1.2.1.26.4.5 | |||
node · current UTP MAU. Note that it is strongly recommended that agents return either dot3MauType10BaseTHD or dot3MauType10BaseTFD if the duplex mode is known. However, management applications should be prepared to receive this MAU type value from older agent implementations. | ||||
| Ndot3MauType10BaseFP | 1.3.6.1.2.1.26.4.6 | |||
node · current passive fiber MAU | ||||
| Ndot3MauType10BaseFB | 1.3.6.1.2.1.26.4.7 | |||
node · current sync fiber MAU | ||||
| Ndot3MauType10BaseFL | 1.3.6.1.2.1.26.4.8 | |||
node · current async fiber MAU. Note that it is strongly recommended that agents return either dot3MauType10BaseFLHD or dot3MauType10BaseFLFD if the duplex mode is known. However, management applications should be prepared to receive this MAU type value from older agent implementations. | ||||
| Ndot3MauType10Broad36 | 1.3.6.1.2.1.26.4.9 | |||
node · current broadband DTE MAU. Note that 10BROAD36 MAUs can be attached to interfaces but not to repeaters. | ||||
| Ndot3MauType10BaseTHD | 1.3.6.1.2.1.26.4.10 | |||
node · current UTP MAU, half duplex mode | ||||
| Ndot3MauType10BaseTFD | 1.3.6.1.2.1.26.4.11 | |||
node · current UTP MAU, full duplex mode | ||||
| Ndot3MauType10BaseFLHD | 1.3.6.1.2.1.26.4.12 | |||
node · current async fiber MAU, half duplex mode | ||||
| Ndot3MauType10BaseFLFD | 1.3.6.1.2.1.26.4.13 | |||
node · current async fiber MAU, full duplex mode | ||||
| Ndot3MauType100BaseT4 | 1.3.6.1.2.1.26.4.14 | |||
node · current 4 pair category 3 UTP | ||||
| Ndot3MauType100BaseTXHD | 1.3.6.1.2.1.26.4.15 | |||
node · current 2 pair category 5 UTP, half duplex mode | ||||
| Ndot3MauType100BaseTXFD | 1.3.6.1.2.1.26.4.16 | |||
node · current 2 pair category 5 UTP, full duplex mode | ||||
| Ndot3MauType100BaseFXHD | 1.3.6.1.2.1.26.4.17 | |||
node · current X fiber over PMT, half duplex mode | ||||
| Ndot3MauType100BaseFXFD | 1.3.6.1.2.1.26.4.18 | |||
node · current X fiber over PMT, full duplex mode | ||||
| Ndot3MauType100BaseT2HD | 1.3.6.1.2.1.26.4.19 | |||
node · current 2 pair category 3 UTP, half duplex mode | ||||
| Ndot3MauType100BaseT2FD | 1.3.6.1.2.1.26.4.20 | |||
node · current 2 pair category 3 UTP, full duplex mode | ||||
| Ndot3MauType1000BaseXHD | 1.3.6.1.2.1.26.4.21 | |||
node · current PCS/PMA, unknown PMD, half duplex mode | ||||
| Ndot3MauType1000BaseXFD | 1.3.6.1.2.1.26.4.22 | |||
node · current PCS/PMA, unknown PMD, full duplex mode | ||||
| Ndot3MauType1000BaseLXHD | 1.3.6.1.2.1.26.4.23 | |||
node · current Fiber over long-wavelength laser, half duplex mode | ||||
| Ndot3MauType1000BaseLXFD | 1.3.6.1.2.1.26.4.24 | |||
node · current Fiber over long-wavelength laser, full duplex mode | ||||
| Ndot3MauType1000BaseSXHD | 1.3.6.1.2.1.26.4.25 | |||
node · current Fiber over short-wavelength laser, half duplex mode | ||||
| Ndot3MauType1000BaseSXFD | 1.3.6.1.2.1.26.4.26 | |||
node · current Fiber over short-wavelength laser, full duplex mode | ||||
| Ndot3MauType1000BaseCXHD | 1.3.6.1.2.1.26.4.27 | |||
node · current Copper over 150-Ohm balanced cable, half duplex mode | ||||
| Ndot3MauType1000BaseCXFD | 1.3.6.1.2.1.26.4.28 | |||
node · current Copper over 150-Ohm balanced cable, full duplex mode | ||||
| Ndot3MauType1000BaseTHD | 1.3.6.1.2.1.26.4.29 | |||
node · current Four-pair Category 5 UTP, half duplex mode | ||||
| Ndot3MauType1000BaseTFD | 1.3.6.1.2.1.26.4.30 | |||
node · current Four-pair Category 5 UTP, full duplex mode | ||||
| Ndot3MauType10GigBaseX | 1.3.6.1.2.1.26.4.31 | |||
node · current X PCS/PMA, unknown PMD. | ||||
| Ndot3MauType10GigBaseLX4 | 1.3.6.1.2.1.26.4.32 | |||
node · current X fiber over WWDM optics | ||||
| Ndot3MauType10GigBaseR | 1.3.6.1.2.1.26.4.33 | |||
node · current R PCS/PMA, unknown PMD. | ||||
| Ndot3MauType10GigBaseER | 1.3.6.1.2.1.26.4.34 | |||
node · current R fiber over 1550 nm optics | ||||
| Ndot3MauType10GigBaseLR | 1.3.6.1.2.1.26.4.35 | |||
node · current R fiber over 1310 nm optics | ||||
| Ndot3MauType10GigBaseSR | 1.3.6.1.2.1.26.4.36 | |||
node · current R fiber over 850 nm optics | ||||
| Ndot3MauType10GigBaseW | 1.3.6.1.2.1.26.4.37 | |||
node · current W PCS/PMA, unknown PMD. | ||||
| Ndot3MauType10GigBaseEW | 1.3.6.1.2.1.26.4.38 | |||
node · current W fiber over 1550 nm optics | ||||
| Ndot3MauType10GigBaseLW | 1.3.6.1.2.1.26.4.39 | |||
node · current W fiber over 1310 nm optics | ||||
| Ndot3MauType10GigBaseSW | 1.3.6.1.2.1.26.4.40 | |||
node · current W fiber over 850 nm optics | ||||
| Ndot3MauType10GigBaseCX4 | 1.3.6.1.2.1.26.4.41 | |||
node · current X copper over 8 pair 100-Ohm balanced cable | ||||
| Ndot3MauType2BaseTL | 1.3.6.1.2.1.26.4.42 | |||
node · current Voice grade UTP copper, up to 2700m, optional PAF | ||||
| Ndot3MauType10PassTS | 1.3.6.1.2.1.26.4.43 | |||
node · current Voice grade UTP copper, up to 750m, optional PAF | ||||
| Ndot3MauType100BaseBX10D | 1.3.6.1.2.1.26.4.44 | |||
node · current One single-mode fiber OLT, long wavelength, 10km | ||||
| Ndot3MauType100BaseBX10U | 1.3.6.1.2.1.26.4.45 | |||
node · current One single-mode fiber ONU, long wavelength, 10km | ||||
| Ndot3MauType100BaseLX10 | 1.3.6.1.2.1.26.4.46 | |||
node · current Two single-mode fibers, long wavelength, 10km | ||||
| Ndot3MauType1000BaseBX10D | 1.3.6.1.2.1.26.4.47 | |||
node · current One single-mode fiber OLT, long wavelength, 10km | ||||
| Ndot3MauType1000BaseBX10U | 1.3.6.1.2.1.26.4.48 | |||
node · current One single-mode fiber ONU, long wavelength, 10km | ||||
| Ndot3MauType1000BaseLX10 | 1.3.6.1.2.1.26.4.49 | |||
node · current Two sigle-mode fiber, long wavelength, 10km | ||||
| Ndot3MauType1000BasePX10D | 1.3.6.1.2.1.26.4.50 | |||
node · current One single-mode fiber EPON OLT, 10km | ||||
| Ndot3MauType1000BasePX10U | 1.3.6.1.2.1.26.4.51 | |||
node · current One single-mode fiber EPON ONU, 10km | ||||
| Ndot3MauType1000BasePX20D | 1.3.6.1.2.1.26.4.52 | |||
node · current One single-mode fiber EPON OLT, 20km | ||||
| Ndot3MauType1000BasePX20U | 1.3.6.1.2.1.26.4.53 | |||
node · current One single-mode fiber EPON ONU, 20km | ||||
| Ndot3MauType10GbaseT | 1.3.6.1.2.1.26.4.54 | |||
node · current Four-pair Category 6A or better, full duplex mode only | ||||
| Ndot3MauType10GbaseLRM | 1.3.6.1.2.1.26.4.55 | |||
node · current R multimode fiber over 1310 nm optics | ||||
| Ndot3MauType1000baseKX | 1.3.6.1.2.1.26.4.56 | |||
node · current X backplane, full duplex mode only | ||||
| Ndot3MauType10GbaseKX4 | 1.3.6.1.2.1.26.4.57 | |||
node · current 4 lane X backplane, full duplex mode only | ||||
| Ndot3MauType10GbaseKR | 1.3.6.1.2.1.26.4.58 | |||
node · current R backplane, full duplex mode only | ||||
| Ndot3MauType10G1GbasePRXD1 | 1.3.6.1.2.1.26.4.59 | |||
node · current One single-mode fiber asymmetric-rate EPON OLT, supporting low power budget (PRX10) | ||||
| Ndot3MauType10G1GbasePRXD2 | 1.3.6.1.2.1.26.4.60 | |||
node · current One single-mode fiber asymmetric-rate EPON OLT, supporting medium power budget (PRX20) | ||||
| Ndot3MauType10G1GbasePRXD3 | 1.3.6.1.2.1.26.4.61 | |||
node · current One single-mode fiber asymmetric-rate EPON OLT, supporting high power budget (PRX30) | ||||
| Ndot3MauType10G1GbasePRXU1 | 1.3.6.1.2.1.26.4.62 | |||
node · current One single-mode fiber asymmetric-rate EPON ONU, supporting low power budget (PRX10) | ||||
| Ndot3MauType10G1GbasePRXU2 | 1.3.6.1.2.1.26.4.63 | |||
node · current One single-mode fiber asymmetric-rate EPON ONU, supporting medium power budget (PRX20) | ||||
| Ndot3MauType10G1GbasePRXU3 | 1.3.6.1.2.1.26.4.64 | |||
node · current One single-mode fiber asymmetric-rate EPON ONU, supporting high power budget (PRX30) | ||||
| Ndot3MauType10GbasePRD1 | 1.3.6.1.2.1.26.4.65 | |||
node · current One single-mode fiber symmetric-rate EPON OLT, supporting low power budget (PR10) | ||||
| Ndot3MauType10GbasePRD2 | 1.3.6.1.2.1.26.4.66 | |||
node · current One single-mode fiber symmetric-rate EPON OLT, supporting medium power budget (PR20) | ||||
| Ndot3MauType10GbasePRD3 | 1.3.6.1.2.1.26.4.67 | |||
node · current One single-mode fiber symmetric-rate EPON OLT, supporting high power budget (PR30) | ||||
| Ndot3MauType10GbasePRU1 | 1.3.6.1.2.1.26.4.68 | |||
node · current One single-mode fiber symmetric-rate EPON ONU, supporting low and medium power budget (PR10 and PR20) | ||||
| Ndot3MauType10GbasePRU3 | 1.3.6.1.2.1.26.4.69 | |||
node · current One single-mode fiber symmetric-rate EPON ONU, supporting high power budget (PR30) | ||||
| Ndot3MauType40GbaseKR4 | 1.3.6.1.2.1.26.4.70 | |||
node · current 40GBASE-R PCS/PMA over an electrical backplane | ||||
| Ndot3MauType40GbaseCR4 | 1.3.6.1.2.1.26.4.71 | |||
node · current 40GBASE-R PCS/PMA over 4 lane shielded copper balanced cable | ||||
| Ndot3MauType40GbaseSR4 | 1.3.6.1.2.1.26.4.72 | |||
node · current 40GBASE-R PCS/PMA over 4 lane multimode fiber | ||||
| Ndot3MauType40GbaseFR | 1.3.6.1.2.1.26.4.73 | |||
node · current 40GBASE-R PCS/PMA over single mode fiber | ||||
| Ndot3MauType40GbaseLR4 | 1.3.6.1.2.1.26.4.74 | |||
node · current 40GBASE-R PCS/PMA over 4 WDM lane single mode fiber | ||||
| Ndot3MauType100GbaseCR10 | 1.3.6.1.2.1.26.4.75 | |||
node · current 100GBASE-R PCS/PMA over 10 lane shielded copper balanced cable | ||||
| Ndot3MauType100GbaseSR10 | 1.3.6.1.2.1.26.4.76 | |||
node · current 100GBASE-R PCS/PMA over 10 lane multimode fiber | ||||
| Ndot3MauType100GbaseLR4 | 1.3.6.1.2.1.26.4.77 | |||
node · current 100GBASE-R PCS/PMA over 4 WDM lane single mode fiber, long reach | ||||
| Ndot3MauType100GbaseER4 | 1.3.6.1.2.1.26.4.78 | |||
node · current 100GBASE-R PCS/PMA over 4 WDM lane single mode fiber PMD, extended reach | ||||
| Ndot3MauType1000baseT1 | 1.3.6.1.2.1.26.4.79 | |||
node · current 1000BASE-T1 single balanced twisted-pair copper cabling PHY | ||||
| Ndot3MauType1000basePX30D | 1.3.6.1.2.1.26.4.80 | |||
node · current One single-mode fiber EPON OLT, 20km, 1:32 split ratio | ||||
| Ndot3MauType1000basePX30U | 1.3.6.1.2.1.26.4.81 | |||
node · current One single-mode fiber EPON ONU, 20km, 1:32 split ratio | ||||
| Ndot3MauType1000basePX40D | 1.3.6.1.2.1.26.4.82 | |||
node · current One single-mode fiber EPON OLT, 20km, 1:64 split ratio | ||||
| Ndot3MauType1000basePX40U | 1.3.6.1.2.1.26.4.83 | |||
node · current One single-mode fiber EPON ONU, 20km, 1:64 split ratio | ||||
| Ndot3MauType10G1GbasePRXD4 | 1.3.6.1.2.1.26.4.84 | |||
node · current One single-mode fiber asymmetric-rate EPON OLT, supporting extended power budget (PRX40) | ||||
| Ndot3MauType10G1GbasePRXU4 | 1.3.6.1.2.1.26.4.85 | |||
node · current One single-mode fiber asymmetric-rate EPON ONU, supporting extended power budget (PRX40) | ||||
| Ndot3MauType10GbasePRD4 | 1.3.6.1.2.1.26.4.86 | |||
node · current One single-mode fiber symmetric-rate EPON OLT, supporting extended power budget (PR40) | ||||
| Ndot3MauType10GbasePRU4 | 1.3.6.1.2.1.26.4.87 | |||
node · current One single-mode fiber symmetric-rate EPON ONU, supporting extended power budget (PR40) | ||||
| Ndot3MauType25GbaseCR | 1.3.6.1.2.1.26.4.88 | |||
node · current 25GBASE-R PCS/PMA over shielded balanced copper cable | ||||
| Ndot3MauType25GbaseCRS | 1.3.6.1.2.1.26.4.89 | |||
node · current 25GBASE-R PCS/PMA over shielded balanced copper cable without RS-FEC | ||||
| Ndot3MauType25GbaseKR | 1.3.6.1.2.1.26.4.90 | |||
node · current 25GBASE-R PCS/PMA over an electrical backplane | ||||
| Ndot3MauType25GbaseKRS | 1.3.6.1.2.1.26.4.91 | |||
node · current 25GBASE-R PCS/PMA over an electrical backplane without RS-FEC | ||||
| Ndot3MauType25GbaseR | 1.3.6.1.2.1.26.4.92 | |||
node · current 25GBASE-R PCS/PMA over undefined PMD | ||||
| Ndot3MauType25GbaseSR | 1.3.6.1.2.1.26.4.93 | |||
node · current 25GBASE-R PCS/PMA over multimode fiber | ||||
| Ndot3MauType25GbaseT | 1.3.6.1.2.1.26.4.94 | |||
node · current Four-pair twisted-pair balanced copper cabling | ||||
| Ndot3MauType40GbaseER4 | 1.3.6.1.2.1.26.4.95 | |||
node · current 40GBASE-R PCS/PMA over 4 WDM lane single mode fiber | ||||
| Ndot3MauType40GbaseR | 1.3.6.1.2.1.26.4.96 | |||
node · current 40GBASE-R PCS as over undefined PMA/PMD | ||||
| Ndot3MauType40GbaseT | 1.3.6.1.2.1.26.4.97 | |||
node · current Four-pair twisted-pair balanced copper cabling | ||||
| Ndot3MauType100GbaseCR4 | 1.3.6.1.2.1.26.4.98 | |||
node · current 100GBASE-R PCS/PMA over 4 lane shielded copper balanced cable | ||||
| Ndot3MauType100GbaseKR4 | 1.3.6.1.2.1.26.4.99 | |||
node · current 100GBASE-R PCS/PMA over an electrical backplane | ||||
| Ndot3MauType100GbaseKP4 | 1.3.6.1.2.1.26.4.100 | |||
node · current 100GBASE-P PCS/PMA over an electrical backplane PMD | ||||
| Ndot3MauType100GbaseR | 1.3.6.1.2.1.26.4.101 | |||
node · current 100GBASE-R Multi-lane PCS over undefined PMA/PMD | ||||
| Ndot3MauType100GbaseSR4 | 1.3.6.1.2.1.26.4.102 | |||
node · current 100GBASE-R PCS/PMA over 4 lane multimode fiber | ||||
| Ndot3MauType2p5GigT | 1.3.6.1.2.1.26.4.103 | |||
node · current 2.5GBASE-T Four-pair twisted-pair balanced copper cabling PHY | ||||
| Ndot3MauType5GigT | 1.3.6.1.2.1.26.4.104 | |||
node · current 5GBASE-T Four-pair twisted-pair balanced copper cabling PHY | ||||
| Ndot3MauType100baseT1 | 1.3.6.1.2.1.26.4.105 | |||
node · current 100BASE-T1 Single balanced twisted-pair copper cabling PHY | ||||
| Ndot3MauType1000baseRHA | 1.3.6.1.2.1.26.4.106 | |||
node · current 1000BASE-RHA Plastic optical fiber PHY | ||||
| Ndot3MauType1000baseRHB | 1.3.6.1.2.1.26.4.107 | |||
node · current 1000BASE-RHB Plastic optical fiber PHY | ||||
| Ndot3MauType1000baseRHC | 1.3.6.1.2.1.26.4.108 | |||
node · current 1000BASE-RHC Plastic optical fiber PHY | ||||
| Ndot3MauType2p5GbaseKX | 1.3.6.1.2.1.26.4.109 | |||
node · current 2.5GBASE-X PMD over an electrical backplane | ||||
| Ndot3MauType2p5GbaseX | 1.3.6.1.2.1.26.4.110 | |||
node · current 2.5GBASE-X PCS/PMA over undefined PMD | ||||
| Ndot3MauType5GbaseKR | 1.3.6.1.2.1.26.4.111 | |||
node · current 5GBASE-KR PMD over an electrical backplane | ||||
| Ndot3MauType5GbaseR | 1.3.6.1.2.1.26.4.112 | |||
node · current 5GBASE-R PCS/PMA over undefined PMD | ||||
| Ndot3MauType10GpassXR | 1.3.6.1.2.1.26.4.113 | |||
node · current Coax cable distribution network PHY continuous downstream/burst mode upstream PHY | ||||
| Ndot3MauType25GbaseLR | 1.3.6.1.2.1.26.4.114 | |||
node · current 25GBASE-R PCS/PMA over single-mode fiber PMD, with long reach | ||||
| Ndot3MauType25GbaseER | 1.3.6.1.2.1.26.4.115 | |||
node · current 25GBASE-R PCS/PMA over single-mode fiber PMD, with extended reach | ||||
| Ndot3MauType50GbaseR | 1.3.6.1.2.1.26.4.116 | |||
node · current 50GBASE-R Multi-lane PCS over undefined PMA/PMD | ||||
| Ndot3MauType50GbaseCR | 1.3.6.1.2.1.26.4.117 | |||
node · current 50GBASE-R PCS/PMA over shielded copper balanced cable PMD | ||||
| Ndot3MauType50GbaseKR | 1.3.6.1.2.1.26.4.118 | |||
node · current 50GBASE-R PCS/PMA over an electrical backplane PMD | ||||
| Ndot3MauType50GbaseSR | 1.3.6.1.2.1.26.4.119 | |||
node · current 50GBASE-R PCS/PMA over multimode fiber PMD | ||||
| Ndot3MauType50GbaseFR | 1.3.6.1.2.1.26.4.120 | |||
node · current 50GBASE-R PCS/PMA over single mode fiber PMD with reach up to at least 2 km | ||||
| Ndot3MauType50GbaseLR | 1.3.6.1.2.1.26.4.121 | |||
node · current 50GBASE-R PCS/PMA over single mode fiber PMD with reach up to at least 10 km | ||||
| Ndot3MauType50GbaseER | 1.3.6.1.2.1.26.4.122 | |||
node · current 50GBASE-R PCS/PMA over single-mode fiber PMD with reach up to at least 40 km | ||||
| Ndot3MauType100GbaseCR2 | 1.3.6.1.2.1.26.4.123 | |||
node · current 100GBASE-R PCS/PMA over 2 lane shielded copper balanced cable PMD | ||||
| Ndot3MauType100GbaseKR2 | 1.3.6.1.2.1.26.4.124 | |||
node · current 100GBASE-R PCS/PMA over an electrical backplane PMD | ||||
| Ndot3MauType100GbaseSR2 | 1.3.6.1.2.1.26.4.125 | |||
node · current 100GBASE-R PCS/PMA over 2 lane multimode fiber PMD | ||||
| Ndot3MauType100GbaseDR | 1.3.6.1.2.1.26.4.126 | |||
node · current 100GBASE-R PCS/PMA over single mode fiber PMD | ||||
| Ndot3MauType200GbaseR | 1.3.6.1.2.1.26.4.127 | |||
node · current 200GBASE-R Multi-lane PCS over undefined PMA/PMD | ||||
| Ndot3MauType200GbaseDR4 | 1.3.6.1.2.1.26.4.128 | |||
node · current 200GBASE-R PCS/PMA over 4-lane single-mode fiber PMD | ||||
| Ndot3MauType200GbaseFR4 | 1.3.6.1.2.1.26.4.129 | |||
node · current 200GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 2 km | ||||
| Ndot3MauType200GbaseLR4 | 1.3.6.1.2.1.26.4.130 | |||
node · current 200GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 10 km | ||||
| Ndot3MauType200GbaseCR4 | 1.3.6.1.2.1.26.4.131 | |||
node · current 200GBASE-R PCS/PMA over 4 lane shielded copper balanced cable PMD | ||||
| Ndot3MauType200GbaseKR4 | 1.3.6.1.2.1.26.4.132 | |||
node · current 200GBASE-R PCS/PMA over an electrical backplane PMD | ||||
| Ndot3MauType200GbaseSR4 | 1.3.6.1.2.1.26.4.133 | |||
node · current 200GBASE-R PCS/PMA over 4 lane multimode fiber PMD | ||||
| Ndot3MauType200GbaseER4 | 1.3.6.1.2.1.26.4.134 | |||
node · current 200GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 40 km | ||||
| Ndot3MauType400GbaseR | 1.3.6.1.2.1.26.4.135 | |||
node · current 400GBASE-R Multi-lane PCS over undefined PMA/PMD | ||||
| Ndot3MauType400GbaseSR16 | 1.3.6.1.2.1.26.4.136 | |||
node · current 400GBASE-R PCS/PMA over 16-lane multimode fiber PMD | ||||
| Ndot3MauType400GbaseDR4 | 1.3.6.1.2.1.26.4.137 | |||
node · current 400GBASE-R PCS/PMA over 4-lane single-mode fiber PMD | ||||
| Ndot3MauType400GbaseFR8 | 1.3.6.1.2.1.26.4.138 | |||
node · current 400GBASE-R PCS/PMA over 8 WDM lane single-mode fiber PMD with reach up to at least 2 km | ||||
| Ndot3MauType400GbaseLR8 | 1.3.6.1.2.1.26.4.139 | |||
node · current 400GBASE-R PCS/PMA over 8 WDM lane single-mode fiber PMD with reach up to at least 10 km | ||||
| Ndot3MauType400GbaseER8 | 1.3.6.1.2.1.26.4.140 | |||
node · current 400GBASE-R PCS/PMA over 8 WDM lane single-mode fiber PMD with reach up to at least 40 km | ||||
| Ndot3MauType10baseT1L | 1.3.6.1.2.1.26.4.141 | |||
node · current 10BASE-T1L Single balanced pair PHY | ||||
| Ndot3MauType10baseT1SHD | 1.3.6.1.2.1.26.4.142 | |||
node · current 10BASE-T1S Single balanced pair PHY, half duplex mode | ||||
| Ndot3MauType10baseT1SMD | 1.3.6.1.2.1.26.4.143 | |||
node · current 10BASE-T1S Single balanced pair PHY, multidrop mode | ||||
| Ndot3MauType10baseT1SFD | 1.3.6.1.2.1.26.4.144 | |||
node · current 10BASE-T1S Single balanced pair PHY, full duplex mode | ||||
| Ndot3MauType100GbaseFR1 | 1.3.6.1.2.1.26.4.145 | |||
node · current 100GBASE-R PCS/PMA over single-mode fiber PMD with reach up to at least 2 km | ||||
| Ndot3MauType100GbaseLR1 | 1.3.6.1.2.1.26.4.146 | |||
node · current 100GBASE-R PCS/PMA over single-mode fiber PMD with reach up to at least 10 km | ||||
| Ndot3MauType400GbaseFR4 | 1.3.6.1.2.1.26.4.147 | |||
node · current 400GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 2 km | ||||
| Ndot3MauType400GbaseLR46 | 1.3.6.1.2.1.26.4.148 | |||
node · current 400GBASE-R PCS/PMA over 4 WDM lane single-mode fiber PMD with reach up to at least 6 km | ||||
| Ndot3MauType400GbaseSR8 | 1.3.6.1.2.1.26.4.149 | |||
node · current 400GBASE-R PCS/PMA over 8-lane multimode fiber PMD as specified in Clause 138 | ||||
| Ndot3MauType400GbaseSR4p2 | 1.3.6.1.2.1.26.4.150 | |||
node · current 400GBASE-R PCS/PMA over 8-lane multimode fiber PMD as specified in Clause 150 | ||||
| Ndot3MauType2p5GbaseT1 | 1.3.6.1.2.1.26.4.151 | |||
node · current Single balanced pair of conductors PHY as specified in Clause 149 | ||||
| Ndot3MauType5GbaseT1 | 1.3.6.1.2.1.26.4.152 | |||
node · current Single balanced pair of conductors PHY as specified in Clause 149 | ||||
| Ndot3MauType10GbaseT1 | 1.3.6.1.2.1.26.4.153 | |||
node · current Single balanced pair of conductors PHY as specified in Clause 149 | ||||
| Ndot3MauType25G10GbasePQGD2 | 1.3.6.1.2.1.26.4.154 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25G10GbasePQGD3 | 1.3.6.1.2.1.26.4.155 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType25G10GbasePQGU2 | 1.3.6.1.2.1.26.4.156 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25G10GbasePQGU3 | 1.3.6.1.2.1.26.4.157 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType25G10GbasePQXD2 | 1.3.6.1.2.1.26.4.158 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25G10GbasePQXD3 | 1.3.6.1.2.1.26.4.159 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType25G10GbasePQXU2 | 1.3.6.1.2.1.26.4.160 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25G10GbasePQXU3 | 1.3.6.1.2.1.26.4.161 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQGD2 | 1.3.6.1.2.1.26.4.162 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQGD3 | 1.3.6.1.2.1.26.4.163 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQGU2 | 1.3.6.1.2.1.26.4.164 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQGU3 | 1.3.6.1.2.1.26.4.165 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQXD2 | 1.3.6.1.2.1.26.4.166 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQXD3 | 1.3.6.1.2.1.26.4.167 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQXU2 | 1.3.6.1.2.1.26.4.168 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType25GbasePQXU3 | 1.3.6.1.2.1.26.4.169 | |||
node · current One single mode fiber, 1 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQGD2 | 1.3.6.1.2.1.26.4.170 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQGD3 | 1.3.6.1.2.1.26.4.171 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQGU2 | 1.3.6.1.2.1.26.4.172 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQGU3 | 1.3.6.1.2.1.26.4.173 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQXD2 | 1.3.6.1.2.1.26.4.174 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQXD3 | 1.3.6.1.2.1.26.4.175 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 10.3125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQXU2 | 1.3.6.1.2.1.26.4.176 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G10GbasePQXU3 | 1.3.6.1.2.1.26.4.177 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 10.3125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQGD2 | 1.3.6.1.2.1.26.4.178 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQGD3 | 1.3.6.1.2.1.26.4.179 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQGU2 | 1.3.6.1.2.1.26.4.180 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQGU3 | 1.3.6.1.2.1.26.4.181 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQXD2 | 1.3.6.1.2.1.26.4.182 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQXD3 | 1.3.6.1.2.1.26.4.183 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 1 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQXU2 | 1.3.6.1.2.1.26.4.184 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50G25GbasePQXU3 | 1.3.6.1.2.1.26.4.185 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 1 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQGD2 | 1.3.6.1.2.1.26.4.186 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQGD3 | 1.3.6.1.2.1.26.4.187 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQGU2 | 1.3.6.1.2.1.26.4.188 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQGU3 | 1.3.6.1.2.1.26.4.189 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQXD2 | 1.3.6.1.2.1.26.4.190 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQXD3 | 1.3.6.1.2.1.26.4.191 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous transmission / 2 x 25.78125 GBd burst mode reception, high power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQXU2 | 1.3.6.1.2.1.26.4.192 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, medium power class, as specified in Clause 141 | ||||
| Ndot3MauType50GbasePQXU3 | 1.3.6.1.2.1.26.4.193 | |||
node · current One single mode fiber, 2 x 25.78125 GBd continuous reception / 2 x 25.78125 GBd burst mode transmission, high power class, as specified in Clause 141 | ||||
| Ndot3MauType100GbaseZR | 1.3.6.1.2.1.26.4.194 | |||
node · current 100GBASE-R PCS/100GBASE-ZR PMA over a PMD with reach up to at least 80 km as specified in Clause 154 | ||||
| Ndot3MauType10GbaseBR10D | 1.3.6.1.2.1.26.4.195 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 10 km as specified in Clause 158 | ||||
| Ndot3MauType10GbaseBR10U | 1.3.6.1.2.1.26.4.196 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 10 km as specified in Clause 158 | ||||
| Ndot3MauType10GbaseBR20D | 1.3.6.1.2.1.26.4.197 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 20 km as specified in Clause 158 | ||||
| Ndot3MauType10GbaseBR20U | 1.3.6.1.2.1.26.4.198 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 20 km as specified in Clause 158 | ||||
| Ndot3MauType10GbaseBR40D | 1.3.6.1.2.1.26.4.199 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 40 km as specified in Clause 158 | ||||
| Ndot3MauType10GbaseBR40U | 1.3.6.1.2.1.26.4.200 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 40 km as specified in Clause 158 | ||||
| Ndot3MauType25GbaseBR10D | 1.3.6.1.2.1.26.4.201 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 10 km as specified in Clause 159 | ||||
| Ndot3MauType25GbaseBR10U | 1.3.6.1.2.1.26.4.202 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 10 km as specified in Clause 159 | ||||
| Ndot3MauType25GbaseBR20D | 1.3.6.1.2.1.26.4.203 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 20 km as specified in Clause 159 | ||||
| Ndot3MauType25GbaseBR20U | 1.3.6.1.2.1.26.4.204 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 20 km as specified in Clause 159 | ||||
| Ndot3MauType25GbaseBR40D | 1.3.6.1.2.1.26.4.205 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 40 km as specified in Clause 159 | ||||
| Ndot3MauType25GbaseBR40U | 1.3.6.1.2.1.26.4.206 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 40 km as specified in Clause 159 | ||||
| Ndot3MauType50GbaseBR10D | 1.3.6.1.2.1.26.4.207 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 10 km as specified in Clause 160 | ||||
| Ndot3MauType50GbaseBR10U | 1.3.6.1.2.1.26.4.208 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 10 km as specified in Clause 160 | ||||
| Ndot3MauType50GbaseBR20D | 1.3.6.1.2.1.26.4.209 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 20 km as specified in Clause 160 | ||||
| Ndot3MauType50GbaseBR20U | 1.3.6.1.2.1.26.4.210 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 20 km as specified in Clause 160 | ||||
| Ndot3MauType50GbaseBR40D | 1.3.6.1.2.1.26.4.211 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 40 km as specified in Clause 160 | ||||
| Ndot3MauType50GbaseBR40U | 1.3.6.1.2.1.26.4.212 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 40 km as specified in Clause 160 | ||||
| Ndot3MauType2p5GbaseAU | 1.3.6.1.2.1.26.4.213 | |||
node · current Glass optical fiber PHY as specified in Clause 166 | ||||
| Ndot3MauType5GbaseAU | 1.3.6.1.2.1.26.4.214 | |||
node · current Glass optical fiber PHY as specified in Clause 166 | ||||
| Ndot3MauType10GbaseAU | 1.3.6.1.2.1.26.4.215 | |||
node · current Glass optical fiber PHY as specified in Clause 166 | ||||
| Ndot3MauType25GbaseAU | 1.3.6.1.2.1.26.4.216 | |||
node · current Glass optical fiber PHY as specified in Clause 166 | ||||
| Ndot3MauType50GbaseAU | 1.3.6.1.2.1.26.4.217 | |||
node · current Glass optical fiber PHY as specified in Clause 166 | ||||
| Ndot3MauType25GbaseT1 | 1.3.6.1.2.1.26.4.218 | |||
node · current Single balanced pair of conductors PHY as specified in Clause 165 | ||||
| Ndot3MauType400GbaseDR42 | 1.3.6.1.2.1.26.4.219 | |||
node · current 400GBASE-R PCS/PMA over 4 single-mode fibers in each direction PMD with reach up to at least 2 km as specified in Clause 124 | ||||
| Ndot3MauType800GbaseCR8 | 1.3.6.1.2.1.26.4.220 | |||
node · current 800GBASE-R PCS/PMA over 8-lane shielded balanced copper cable PMD as specified in Clause 162 | ||||
| Ndot3MauType800GbaseDR8 | 1.3.6.1.2.1.26.4.221 | |||
node · current 800GBASE-R PCS/PMA over 8 single-mode fibers in each direction PMD with reach up to at least 500 m as specified in Clause 124 | ||||
| Ndot3MauType800GbaseDR82 | 1.3.6.1.2.1.26.4.222 | |||
node · current 800GBASE-R PCS/PMA over 8 single-mode fibers in each direction PMD with reach up to at least 2 km as specified in Clause 124 | ||||
| Ndot3MauType800GbaseKR8 | 1.3.6.1.2.1.26.4.223 | |||
node · current 800GBASE-R PCS/PMA over an electrical backplane PMD as specified in Clause 163 | ||||
| Ndot3MauType800GbaseR | 1.3.6.1.2.1.26.4.224 | |||
node · current Multi-lane PCS as specified in Clause 172 over undefined PMA/PMD | ||||
| Ndot3MauType800GbaseSR8 | 1.3.6.1.2.1.26.4.225 | |||
node · current 800GBASE-R PCS/PMA over 8 multimode fibers in each direction PMD with reach up to at least 100 m as specified in Clause 167 | ||||
| Ndot3MauType800GbaseVR8 | 1.3.6.1.2.1.26.4.226 | |||
node · current 800GBASE-R PCS/PMA over 8 multimode fibers in each direction PMD with reach up to at least 50 m as specified in Clause 167 | ||||
| Ndot3MauType10GbaseSP1D | 1.3.6.1.2.1.26.4.227 | |||
node · current Super-PON OLT PHY, 10 Gb/s downstream, over one single-mode fiber supporting a distance of at least 50 km as specified in Clause 164 | ||||
| Ndot3MauType10GbaseSP1U | 1.3.6.1.2.1.26.4.228 | |||
node · current Super-PON ONU PHY, 10 Gb/s upstream, over one single-mode fiber supporting a distance of at least 50 km as specified in Clause 164 | ||||
| Ndot3MauType10G2p5GbaseSP1D | 1.3.6.1.2.1.26.4.229 | |||
node · current Super-PON OLT PHY, 10 Gb/s downstream / 2.5 Gb/s upstream, over one single-mode fiber supporting a distance of at least 50 km as specified in Clause 164 | ||||
| Ndot3MauType10G2p5GbaseSP1U | 1.3.6.1.2.1.26.4.230 | |||
node · current Super-PON ONU PHY, 10 Gb/s downstream / 2.5 Gb/s upstream, over one single-mode fiber supporting a distance of at least 50 km as specified in Clause 164 | ||||
| Ndot3MauType100GbaseSR1 | 1.3.6.1.2.1.26.4.231 | |||
node · current 100GBASE-R PCS/PMA over 1 multimode fiber in each direction PMD with reach up to at least 100 m as specified in Clause 167 | ||||
| Ndot3MauType100GbaseVR1 | 1.3.6.1.2.1.26.4.232 | |||
node · current 100GBASE-R PCS/PMA over 1 multimode fiber in each direction PMD with reach up to at least 50 m as specified in Clause 167 | ||||
| Ndot3MauType200GbaseSR2 | 1.3.6.1.2.1.26.4.233 | |||
node · current 200GBASE-R PCS/PMA over 2 multimode fibers in each direction PMD with reach up to at least 100 m as specified in Clause 167 | ||||
| Ndot3MauType200GbaseVR2 | 1.3.6.1.2.1.26.4.234 | |||
node · current 200GBASE-R PCS/PMA over 2 multimode fibers in each direction PMD with reach up to at least 50 m as specified in Clause 167 | ||||
| Ndot3MauType400GbaseSR4 | 1.3.6.1.2.1.26.4.235 | |||
node · current 400GBASE-R PCS/PMA over 4 multimode fibers in each direction PMD with reach up to at least 100 m as specified in Clause 167 | ||||
| Ndot3MauType400GbaseVR4 | 1.3.6.1.2.1.26.4.236 | |||
node · current 400GBASE-R PCS/PMA over 4 multimode fibers in each direction PMD with reach up to at least 50 m as specified in Clause 167 | ||||
| Ndot3MauType100GbaseCR1 | 1.3.6.1.2.1.26.4.237 | |||
node · current 100GBASE-R PCS/PMA over 1-lane shielded balanced copper cable PMD as specified in Clause 162 | ||||
| Ndot3MauType100GbaseKR1 | 1.3.6.1.2.1.26.4.238 | |||
node · current 100GBASE-R PCS/PMA over an electrical backplane PMD as specified in Clause 163 | ||||
| Ndot3MauType200GbaseCR2 | 1.3.6.1.2.1.26.4.239 | |||
node · current 200GBASE-R PCS/PMA over 2-lane shielded balanced copper cable PMD as specified in Clause 162 | ||||
| Ndot3MauType200GbaseKR2 | 1.3.6.1.2.1.26.4.240 | |||
node · current 200GBASE-R PCS/PMA over an electrical backplane PMD as specified in Clause 163 | ||||
| Ndot3MauType400GbaseCR4 | 1.3.6.1.2.1.26.4.241 | |||
node · current 400GBASE-R PCS/PMA over 4-lane shielded balanced copper cable PMD as specified in Clause 162 | ||||
| Ndot3MauType400GbaseKR4 | 1.3.6.1.2.1.26.4.242 | |||
node · current 400GBASE-R PCS/PMA over an electrical backplane PMD as specified in Clause 163 | ||||
| Ndot3MauType10baseT1M | 1.3.6.1.2.1.26.4.243 | |||
node · current 10BASE-T1M Single balanced pair multidrop PHY as specified in Clause 188 | ||||
| Ndot3MauType100GbaseBR10D | 1.3.6.1.2.1.26.4.244 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 10 km as specified in Clause 168 | ||||
| Ndot3MauType100GbaseBR10U | 1.3.6.1.2.1.26.4.245 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 10 km as specified in Clause 168 | ||||
| Ndot3MauType100GbaseBR20D | 1.3.6.1.2.1.26.4.246 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 20 km as specified in Clause 168 | ||||
| Ndot3MauType100GbaseBR20U | 1.3.6.1.2.1.26.4.247 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 20 km as specified in Clause 168 | ||||
| Ndot3MauType100GbaseBR40D | 1.3.6.1.2.1.26.4.248 | |||
node · current One single-mode fiber OLT PHY supporting a distance of at least 40 km as specified in Clause 168 | ||||
| Ndot3MauType100GbaseBR40U | 1.3.6.1.2.1.26.4.249 | |||
node · current One single-mode fiber ONU PHY supporting a distance of at least 40 km as specified in Clause 168 | ||||
| Ndot3MauType100baseT1L | 1.3.6.1.2.1.26.4.250 | |||
node · current 100BASE-T1L Single balanced pair PHY as specified in Clause 190 | ||||
| IianaMauMIB | 1.3.6.1.2.1.154 | |||
identity This MIB module defines dot3MauType OBJECT-IDENTITIES and IANAifMauListBits, IANAifMauMediaAvailable, IANAifMauAutoNegCapBits, and IANAifJackType TEXTUAL-CONVENTIONs, specifying enumerated values of the ifMauTypeListBits, ifMauMediaAvailable / rpMauMediaAvailable, ifMauAutoNegCapabilityBits / ifMauAutoNegCapAdvertisedBits / ifMauAutoNegCapReceivedBits and ifJackType / rpJackType objects respectively, defined in the MAU-MIB. It is intended that each new MAU type, Media Availability state, Auto Negotiation capability and/or Jack type defined by the IEEE 802.3 working group and approved for publication in a revision of IEEE Std 802.3 will be added to this MIB module, provided that it is suitable for being managed by the base objects in the MAU-MIB. An Expert Review, as defined in RFC 2434 [RFC2434], is REQUIRED for such additions. The following reference is used throughout this MIB module: [IEEE802.3] refers to IEEE Std 802.3-2022: 'IEEE Standard for Ethernet'. This reference should be updated as appropriate when new MAU types, Media Availability states, Auto Negotiation capabilities, and/or Jack types are added to this MIB module. Copyright (C) The IETF Trust (2007). The initial version of this MIB module was published in RFC 4836; for full legal notices see the RFC itself. Supplementary information may be available at: http://www.ietf.org/copyrights/ianamib.html | ||||
Textual conventions
IANAifJackTypeINTEGERbnc(5)cx4(15)db9(4)fAUI(6)fiberLC(14)fiberMIC(9)fiberSC(8)fiberST(10)hssdc(13)mAUI(7)mtrj(12)other(1)rj45(2)rj45S(3)sfpPlusDA(16)telco(11)Common enumeration values for repeater and interface MAU jack types. This data type is used as the syntax of the ifJackType and rpJackType objects in the (updated) definition of MAU-MIB's ifJackTable and rpJackTable respectively. Possible values are: other(1) - undefined or unknown rj45(2) - RJ45 rj45S(3) - RJ45 shielded db9(4) - DB9 bnc(5) - BNC fAUI(6) - AUI female mAUI(7) - AUI male fiberSC(8) - SC fiber fiberMIC(9) - MIC fiber fiberST(10) - ST fiber telco(11) - Telco mtrj(12) - MT-RJ fiber hssdc(13) - fiber channel style-2 fiberLC(14) - LC fiber cx4(15) - IB4X for 10GBASE-CX4 sfpPlusDA(16) - SFP+ Direct Attach for 10GE The most recent version of this textual convention is available in the online version of this MIB module on the IANA web site. Requests for new values should be made to IANA via email (iana&iana.org).IANAifMauAutoNegCapBitsBitsb1000baseKX(17)b1000baseT(14)b1000baseT1(23)b1000baseTFD(15)b1000baseX(12)b1000baseXFD(13)b100GbaseCR10(22)b100GbaseCR4(30)b100GbaseKP4(32)b100GbaseKR4(31)b100GbaseR1(48)b100GbaseR2(39)b100baseT1L(51)b100baseT2(6)b100baseT2FD(7)b100baseT4(3)b100baseTX(4)b100baseTXFD(5)b10GbaseKR(19)b10GbaseKX4(18)b10GbaseT(16)b10GbaseT1(45)b10baseT(1)b10baseT1L(41)b10baseT1S(42)b10baseTFD(2)b200GbaseR2(49)b200GbaseR4(40)b25GbaseR(25)b25GbaseRS(24)b25GbaseT(28)b25GbaseT1(46)b2p5GbaseKX(36)b2p5GbaseT(34)b2p5GbaseT1(43)b400GbaseR4(50)b40GbaseCR4(21)b40GbaseKR4(20)b40GbaseT(29)b50GbaseR(38)b5GBaseT(35)b5GbaseKR(37)b5GbaseT1(44)b800GR8(47)bBaseFEC25Greq(27)bFdxAPause(9)bFdxBPause(11)bFdxPause(8)bFdxSPause(10)bForceMS(33)bOther(0)bRSFEC25Greq(26)This data type is used as the syntax of the ifMauAutoNegCapabilityBits, ifMauAutoNegCapAdvertisedBits, and ifMauAutoNegCapReceivedBits objects in the (updated) definition of MAU-MIB's ifMauAutoNegTable. The most recent version of this textual convention is available in the online version of this MIB module on the IANA web site. Requests for new values should be made to IANA via email (iana&iana.org).
IANAifMauMediaAvailableINTEGERautoNegError(11)available(3)availableReduced(19)dxsLinkFault(17)excessiveBER(16)invalidSignal(6)notAvailable(4)offline(10)other(1)pcsLinkFault(15)pmdLinkFault(12)pxsLinkFault(18)ready(20)remoteFault(5)remoteJabber(7)remoteLinkLoss(8)remoteTest(9)unknown(2)wisFrameLoss(13)wisSignalLoss(14)This data type is used as the syntax of the ifMauMediaAvailable and rpMauMediaAvailable objects in the (updated) definition of MAU-MIB's ifMauTable and rpMauTable respectively. Possible values are: other(1) - undefined (not listed below) unknown(2) - MAU's true state is unknown; e.g., during initialization available(3) - link, light, or loopback is normal notAvailable(4) - link loss, low light, or no loopback remoteFault(5) - a fault has been detected at the remote end of the link. This value applies to 10BASE-FB, 100BASE-T4 Far End Fault Indication and non-specified remote faults from a system running auto-negotiation invalidSignal(6) - invalid signal has been received from the other end of the link, 10BASE-FB only remoteJabber(7) - remote fault, due to jabber remoteLinkLoss(8) - remote fault, due to link loss remoteTest(9) - remote fault, due to test offline(10) - offline, Clause 37 Auto-Negotiation only autoNegError(11) - Auto-Negotiation Error, Clause 37 Auto-Negotiation only pmdLinkFault(12) - PMA/PMD receive link fault. In case of PAF (2BASE-TL / 10PASS-TS PHYs), all PMEs in the aggregation group have detected a link fault wisFrameLoss(13) - WIS loss of frame, 10GBASE-W only wisSignalLoss(14) - WIS loss of signal, 10GBASE-W only pcsLinkFault(15) - PCS receive link fault excessiveBER(16) - PCS Bit Error Ratio monitor reporting excessive error ratio dxsLinkFault(17) - DTE XGXS receive link fault, XAUI only pxsLinkFault(18) - PHY XGXS receive link fault, XAUI only availableReduced(19) - link normal, reduced bandwidth, 2BASE-TL / 10PASS-TS only ready(20) - at least one PME in the aggregation group is detecting handshake tones, 2BASE-TL / 10PASS-TS only If the MAU is a 10M b/s link or fiber type (FOIRL, 10BASE-T, 10BASE-F), then this is equivalent to the link test fail state/low light function. For an AUI, 10BASE2, 10BASE5, or 10BROAD36 MAU, this indicates whether loopback is detected on the DI circuit. The value of this attribute persists between packets for MAU types AUI, 10BASE5, 10BASE2, 10BROAD36, and 10BASEFP. At power-up or following a reset, the Media Available state will be unknown(2) for AUI, 10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP MAUs. For these MAUs loopback will be tested on each transmission during which no collision is detected. If DI is receiving input when DO returns to IDL after a transmission and there has been no collision during the transmission, then loopback will be detected. The Media Available state will only change during noncollided transmissions for AUI, 10BASE2, 10BASE5, 10BROAD36, and 10BASE-FP MAUs. For 100BASE-T2, 100BASE-T4, 100BASE-TX, 100BASE-FX, 100BASE-LX10, and 100BASE-BX10 PHYs the enumerations match the states within the link integrity state diagram. Any MAU that implements management of [IEEE802.3] Clause 28 Auto-Negotiation, will map remote fault indication to remoteFault(5). Any MAU that implements management of Clause 37 Auto-Negotiation, will map the received RF1 and RF2 bits as follows: Offline maps to offline(10), Link_Failure maps to remoteFault(5), and Auto-Negotiation Error maps to autoNegError(11). The value remoteFault(5) applies to 10BASE-FB remote fault indication, the 100BASE-X far-end fault indication, and nonspecified remote faults from a system running Clause 28 Auto-Negotiation. The value remoteJabber(7), remoteLink loss(8), or remoteTest(9) SHOULD be used instead of remoteFault(5) where the reason for remote fault is identified in the remote signaling protocol. Where a Clause 22 MII or Clause 35 GMII is present, a logic one in the remote fault bit maps to the value remoteFault(5), a logic zero in the link status bit maps to the enumeration notAvailable(4). The value notAvailable(4) takes precedence over remoteFault(5). For 2BASE-TL and 10PASS-TS PHYs, the value unknown(2) maps to the condition where the PHY (PCS with connected PMEs) is initializing, the value ready(20) maps to the condition where the interface is down and at least one PME in the aggregation group is ready for handshake, the value available(3) maps to the condition where all the PMEs in the aggregation group are up, the value notAvailable(4) maps to the condition where all the PMEs in the aggregation group are down and no handshake tones are detected, the value availableReduced(19) maps to the condition where the interface is up, a link fault is detected at the receive direction by one or more PMEs in the aggregation group, but at least one PME is up and the enumeration pmdLinkFault(12) maps to the condition where a link fault is detected at the receive direction by all of the PMEs in the aggregation group. For 10 Gb/s the enumerations map to value of the link_fault variable within the Link Fault Signaling state diagram as follows: the value OK maps to the value available(3), the value Local Fault maps to the value notAvailable(4), and the value Remote Fault maps to the value remoteFault(5). The value pmdLinkFault(12), wisFrameLoss(13), wisSignalLoss(14), pcsLinkFault(15), excessiveBER(16), or dxsLinkFault(17) SHOULD be used instead of the value notAvailable(4), where the reason for the Local Fault state can be identified through the use of the Clause 45 MDIO Interface. Where multiple reasons for the Local Fault state can be identified, only the highest precedence error SHOULD be reported. This precedence in descending order is as follows: pxsLinkFault pmdLinkFault wisFrameLoss wisSignalLoss pcsLinkFault excessiveBER dxsLinkFault. Where a Clause 45 MDIO interface is present a logic zero in the PMA/PMD Receive link status bit ([IEEE802.3] Section 45.2.1.2.2) maps to the value pmdLinkFault(12), logic one in the LOF status bit (Section 45.2.2.10.4) maps to the value wisFrameLoss(13), a logic one in the LOS status bit (Section 45.2.2.10.5) maps to the value wisSignalLoss, a logic zero in the PCS Receive link status bit (Section 45.2.3.2.2) maps to the value pcsLinkFault(15), a logic one in the 10GBASE-R PCS Latched high BER status bit (Section 45.2.3.12.2) maps to the value excessiveBER, a logic zero in the DTE XS receive link status bit (Section 45.2.5.2.2) maps to the value dxsLinkFault(17) and a logic zero in the PHY XS transmit link status bit (Section 45.2.4.2.2) maps to the value pxsLinkFault(18). The most recent version of this textual convention is available in the online version of this MIB module on the IANA web site. Requests for new values should be made to IANA via email (iana&iana.org).IANAifMauTypeListBitsBitsb1000BaseBX10D(47)b1000BaseBX10U(48)b1000BaseLX10(49)b1000BasePX10D(50)b1000BasePX10U(51)b1000BasePX20D(52)b1000BasePX20U(53)b1000baseCXFD(28)b1000baseCXHD(27)b1000baseKX(56)b1000baseLXFD(24)b1000baseLXHD(23)b1000basePX30D(80)b1000basePX30U(81)b1000basePX40D(82)b1000basePX40U(83)b1000baseRHA(106)b1000baseRHB(107)b1000baseRHC(108)b1000baseSXFD(26)b1000baseSXHD(25)b1000baseT1(79)b1000baseTFD(30)b1000baseTHD(29)b1000baseXFD(22)b1000baseXHD(21)b100BaseBX10D(44)b100BaseBX10U(45)b100BaseLX10(46)b100GbaseBR10D(244)b100GbaseBR10U(245)b100GbaseBR20D(246)b100GbaseBR20U(247)b100GbaseBR40D(248)b100GbaseBR40U(249)b100GbaseCR1(237)b100GbaseCR10(75)b100GbaseCR2(123)b100GbaseCR4(98)b100GbaseDR(126)b100GbaseER4(78)b100GbaseFR1(145)b100GbaseKP4(100)b100GbaseKR1(238)b100GbaseKR2(124)b100GbaseKR4(99)b100GbaseLR1(146)b100GbaseLR4(77)b100GbaseR(101)b100GbaseSR1(231)b100GbaseSR10(76)b100GbaseSR2(125)b100GbaseSR4(102)b100GbaseVR1(232)b100GbaseZR(194)b100baseFXFD(18)b100baseFXHD(17)b100baseT1(105)b100baseT1L(250)b100baseT2FD(20)b100baseT2HD(19)b100baseT4(14)b100baseTXFD(16)b100baseTXHD(15)b10G1GbasePRXD1(59)b10G1GbasePRXD2(60)b10G1GbasePRXD3(61)b10G1GbasePRXD4(84)b10G1GbasePRXU1(62)b10G1GbasePRXU2(63)b10G1GbasePRXU3(64)b10G1GbasePRXU4(85)b10G2p5GbaseSP1D(229)b10G2p5GbaseSP1U(230)b10GbaseAU(215)b10GbaseBR10D(195)b10GbaseBR10U(196)b10GbaseBR20D(197)b10GbaseBR20U(198)b10GbaseBR40D(199)b10GbaseBR40U(200)b10GbaseCX4(41)b10GbaseER(34)b10GbaseEW(38)b10GbaseKR(58)b10GbaseKX4(57)b10GbaseLR(35)b10GbaseLRM(55)b10GbaseLW(39)b10GbaseLX4(32)b10GbasePRD1(65)b10GbasePRD2(66)b10GbasePRD3(67)b10GbasePRD4(86)b10GbasePRU1(68)b10GbasePRU3(69)b10GbasePRU4(87)b10GbaseR(33)b10GbaseSP1D(227)b10GbaseSP1U(228)b10GbaseSR(36)b10GbaseSW(40)b10GbaseT(54)b10GbaseT1(153)b10GbaseW(37)b10GbaseX(31)b10GpassXR(113)b10PassTS(43)b10base2(4)b10base5(2)b10baseFB(7)b10baseFL(8)b10baseFLFD(13)b10baseFLHD(12)b10baseFP(6)b10baseT(5)b10baseT1L(141)b10baseT1M(243)b10baseT1SFD(144)b10baseT1SHD(142)b10baseT1SMD(143)b10baseTFD(11)b10baseTHD(10)b10broad36(9)b200GbaseCR2(239)b200GbaseCR4(131)b200GbaseDR4(128)b200GbaseER4(134)b200GbaseFR4(129)b200GbaseKR2(240)b200GbaseKR4(132)b200GbaseLR4(130)b200GbaseR(127)b200GbaseSR2(233)b200GbaseSR4(133)b200GbaseVR2(234)b25G10GbasePQGD2(154)b25G10GbasePQGD3(155)b25G10GbasePQGU2(156)b25G10GbasePQGU3(157)b25G10GbasePQXD2(158)b25G10GbasePQXD3(159)b25G10GbasePQXU2(160)b25G10GbasePQXU3(161)b25GbaseAU(216)b25GbaseBR10D(201)b25GbaseBR10U(202)b25GbaseBR20D(203)b25GbaseBR20U(204)b25GbaseBR40D(205)b25GbaseBR40U(206)b25GbaseCR(88)b25GbaseCRS(89)b25GbaseER(115)b25GbaseKR(90)b25GbaseKRS(91)b25GbaseLR(114)b25GbasePQGD2(162)b25GbasePQGD3(163)b25GbasePQGU2(164)b25GbasePQGU3(165)b25GbasePQXD2(166)b25GbasePQXD3(167)b25GbasePQXU2(168)b25GbasePQXU3(169)b25GbaseR(92)b25GbaseSR(93)b25GbaseT(94)b25GbaseT1(218)b2BaseTL(42)b2p5GbaseAU(213)b2p5GbaseKX(109)b2p5GbaseT(103)b2p5GbaseT1(151)b2p5GbaseX(110)b400GbaseCR4(241)b400GbaseDR4(137)b400GbaseDR42(219)b400GbaseER8(140)b400GbaseFR4(147)b400GbaseFR8(138)b400GbaseKR4(242)b400GbaseLR46(148)b400GbaseLR8(139)b400GbaseR(135)b400GbaseSR16(136)b400GbaseSR4(235)b400GbaseSR4p2(150)b400GbaseSR8(149)b400GbaseVR4(236)b40GbaseCR4(71)b40GbaseER4(95)b40GbaseFR(73)b40GbaseKR4(70)b40GbaseLR4(74)b40GbaseR(96)b40GbaseSR4(72)b40GbaseT(97)b50G10GbasePQGD2(170)b50G10GbasePQGD3(171)b50G10GbasePQGU2(172)b50G10GbasePQGU3(173)b50G10GbasePQXD2(174)b50G10GbasePQXD3(175)b50G10GbasePQXU2(176)b50G10GbasePQXU3(177)b50G25GbasePQGD2(178)b50G25GbasePQGD3(179)b50G25GbasePQGU2(180)b50G25GbasePQGU3(181)b50G25GbasePQXD2(182)b50G25GbasePQXD3(183)b50G25GbasePQXU2(184)b50G25GbasePQXU3(185)b50GbaseAU(217)b50GbaseBR10D(207)b50GbaseBR10U(208)b50GbaseBR20D(209)b50GbaseBR20U(210)b50GbaseBR40D(211)b50GbaseBR40U(212)b50GbaseCR(117)b50GbaseER(122)b50GbaseFR(120)b50GbaseKR(118)b50GbaseLR(121)b50GbasePQGD2(186)b50GbasePQGD3(187)b50GbasePQGU2(188)b50GbasePQGU3(189)b50GbasePQXD2(190)b50GbasePQXD3(191)b50GbasePQXU2(192)b50GbasePQXU3(193)b50GbaseR(116)b50GbaseSR(119)b5GbaseAU(214)b5GbaseKR(111)b5GbaseR(112)b5GbaseT(104)b5GbaseT1(152)b800GbaseCR8(220)b800GbaseDR8(221)b800GbaseDR82(222)b800GbaseKR8(223)b800GbaseR(224)b800GbaseSR8(225)b800GbaseVR8(226)bAUI(1)bFoirl(3)bOther(0)This data type is used as the syntax of the ifMauTypeListBits object in the (updated) definition of MAU-MIB's ifMauTable. The most recent version of this textual convention is available in the online version of this MIB module on the IANA web site. Requests for new values should be made to IANA via email (iana&iana.org). Note that changes in this textual convention SHALL be synchronized with relevant changes in the dot3MauType OBJECT-IDENTITIES.